Package Outline Drawing (POD)

Hermetic Packages for Integrated Circuits
Ceramic Metal Seal Flatpack Packages (Flatpack)
E
1
K42.A TOP BRAZED
42 LEAD CERAMIC METAL SEAL FLATPACK PACKAGE
N
e
INCHES
A
A
D
b
E1
S1
L
C
Q
A
E2
c1
LEAD FINISH
BASE
METAL
(c)
SYMBOL
MILLIMETERS
MIN
MAX
MIN
MAX
NOTES
A
-
b
0.017
0.100
-
2.54
-
0.025
0.43
0.64
-
b1
c
0.017
0.023
0.43
0.58
-
0.007
0.013
0.18
0.33
-
c1
0.007
0.010
0.18
0.25
-
D
1.045
1.075
26.54
27.31
3
16.00
16.51
-
17.27
3
E
0.630
0.650
E1
-
0.680
E2
0.530
0.550
e
13.46
0.050 BSC
13.97
1.27 BSC
11
k
-
-
-
-
-
L
0.320
0.350
8.13
8.89
-
(b)
Q
0.045
0.065
1.14
1.65
8
SECTION A-A
S1
0.000
-
0.00
-
6
M
-
0.0015
-
b1
M
M
NOTES:
1. Index area: A notch or a pin one identification mark shall be located adjacent to pin one and shall be located within the shaded
area shown. The manufacturer’s identification shall not be used
as a pin one identification mark. Alternately, a tab (dimension k)
may be used to identify pin one.
2. If a pin one identification mark is used in addition to a tab, the limits of dimension k do not apply.
3. This dimension allows for off-center lid, meniscus, and glass
overrun.
4. Dimensions b1 and c1 apply to lead base metal only. Dimension
M applies to lead plating and finish thickness. The maximum limits of lead dimensions b and c or M shall be measured at the centroid of the finished lead surfaces, when solder dip or tin plate
lead finish is applied.
5. N is the maximum number of terminal positions.
6. Measure dimension S1 at all four corners.
7. For bottom-brazed lead packages, no organic or polymeric materials shall be molded to the bottom of the package to cover the
leads.
8. Dimension Q shall be measured at the point of exit (beyond the
meniscus) of the lead from the body. Dimension Q minimum
shall be reduced by 0.0015 inch (0.038mm) maximum when solder dip lead finish is applied.
9. Dimensioning and tolerancing per ANSI Y14.5M - 1982.
10. Controlling dimension: INCH.
11. The basic lead spacing is 0.050 inch (1.27mm) between center
lines. Each lead centerline shall be located within ±0.005 inch
(0.13mm) of its exact longitudinal position relative to lead 1 and
the highest numbered (N) lead.
56
N
42
0.04
42
-
Rev. 0 6/17/94