Specs

JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 75SA-081
SWITCH ASSEMBLY
Frequency Range
DC-2150 MHz
Configuration
2 individually controlled 1P16T normally open selfterminating electro-mechanical RF switches
Enclosure Type
19 inch rack mount @ 4RU high
Impedance
75 Ohms nominal
Startup/Default States
(configurable)
RF Switch off at startup (see SWITCH command)
DHCP enabled (see NET command)
4 Ethernet users (see NET command)
Prompts off (see PROMPT command)
All of these default settings can be changed by user.
Unit can be configured for up to 12 Ethernet users.
VSWR
1.7:1 maximum
1.5:1 typical
Insertion Loss
2.00 dB maximum
0.75 dB typical
1.50 dB typical
DC-2150MHz
DC-1000MHz
1000-2150MHz
Isolation
70 dB minimum
50 dB minimum
DC-1000 MHz
1000-2150 MHz
RF Input Power
+27 dBm maximum
Switching Speed
10 milliseconds
(after command is received and processed)
(3 milliseconds typical processing time)
Manual Control
20-Button Keypad and LCD display
(IP Address configurable via keypad)
(Net mask configurable via keypad)
(Gateway configurable via keypad)
(Baud rate configurable via keypad)
Remote Control
Ethernet (DHCP, TCP/IP, 10/100, up to 12 users)
RS-232 (up to 115200 Baud)
--CONTINUED-Page 1 of 2
JFW FORM E-7-F REV F
JFW Industries, Inc.
Phone: 317-887-1340
[email protected]
www.jfwindustries.com
SPECIFICATION SHEET
JFW MODEL 75SA-081
SWITCH ASSEMBLY
Remote Commands
RF Switch Control Commands:
Switch, Set Switch, Read Switch
System Commands:
Help, Identification, Store, Recall, Pause, Net,
Serial, Close, Disconnect, MOTD, Date, Message,
Restrict, IDENT, Name, Show Users, Reboot, Uptime,
Prompt
AC Supply
100-240 VAC @ 47-63 Hz
2 Amp 5x20mm "Slo-Blo" AC fuse
Littelfuse #215-002, JFW #025-021
RF Connector
F female
Operating Temperature Range
0º to +50º C
Physical Size
See outline drawing 092-7907
ECR/ECN #
DATE
REV
01/07/2014
Page 2 of 2
APPR / DATE
ECR/ECN #
CLK 01/07/2014
24052
04/22/2014
A
CLK 04/22/2014
25257
04/28/2015
B
CLK 04/28/2015
JFW FORM E-7-F REV F
DATE
REV
APPR / DATE