Float standard programme ID letter: A/M/K Dimension (mm):Ø40 x 27 Material: POM Depth of immersion Weighing h1(mm) y (g/cm3) 18 1 20 0.9 22.5 0.8 26 0.7 ID letter: T/C/I Dimension (mm): Ø30 x 44 Material: PP Depth of immersion Weighing h1(mm) y (g/cm3) 27.5 1 30.5 0.9 34.5 0.8 39.5 0.7 ID letter: R/S/U Dimension (mm):Ø30 x 44 Material: NBR Depth of immersion Weighing h1(mm) y (g/cm3) 19.5 1 22 0.9 24.5 0.8 28 0.7 Part No.: Part No.: Part No.: 494.5206.009 494.5203.019 494.5203.031 ID letter: V/L/D Dimension (mm):Ø42 x 44 Material: PVC Depth of immersion Weighing h1(mm) y (g/cm3) 25 1 27.5 0.9 30.5 0.8 35 0.7 ID letter: N/P Dimension (mm): Ø44 x 45 Material: 1.4571 Depth of immersion Weighing h1(mm) y (g/cm3) 32 1 35 0.9 39 0.8 45 0.7 ID letter: E/F Dimension (mm): Ø52 Material: 1.4571 Depth of immersion Weighing h1(mm) y (g/cm3) 32 1 34 0.9 37 0.8 43 0.7 Part No.: Part No.: Part No.: 494.5215.029 494.2104.002 ID letter: B/O Dimension (mm): Ø62 Material: 1.4571 Depth of immersion Weighing h1(mm) y (g/cm3) 33 1 35 0.9 38 0.8 42 0.7 ID letter: G/H Dimension (mm): Ø84 Material: 1.4571 Depth of immersion Weighing h1(mm) y (g/cm3) 33 1 35 0.9 38 0.8 42 0.7 Part No.: Part No.: 232 494.2102.001 494.2101.004 494.2105.003 ID letter: V/L/D Dimension (mm):Ø52 x 55 Material: PVC Depth of immersion Weighing h1(mm) y (g/cm3) 29 1 32 0.9 36 0.8 42 0.7 ID letter: N/P Dimension (mm):Ø52 x 55 Material: 1.4571 Depth of immersion Weighing h1(mm) y (g/cm3) 33 1 36 0.9 40.5 0.8 46 0.7 Part No.: Part No.: 494.5216.032 Sensors Adjustable floats 494.2299.023 Miniature floats ID letter: K1 Dimension (mm):Ø25 x 21 Material: PP Depth of immersion Weighing h1(mm) y (g/cm3) 12 1 13 0.9 14.5 0.8 16.5 0.7 ID letter: K2 Dimension (mm):Ø25 x 21 Material: PVC Depth of immersion Weighing h1(mm) y (g/cm3) 15 1 16 0.9 18.5 0.8 – 0.7 ID letter: K4 Dimension (mm):Ø23 x 25 Material: NBR Depth of immersion Weighing h1(mm) y (g/cm3) 16 1 17.5 0.9 19.5 0.8 22 0.7 Part No.: Part No.: Art.-Nr.: 494.5207.021 494.5207.022 ID letter: K3 Dimension (mm):Ø20 x 20 Material: NBR Depth of immersion Weighing h1(mm) y (g/cm3) 15 1 17 0.9 – 0.8 – 0.7 ID letter: N1 Dimension (mm): Ø30 Material: 1.4571 Depth of immersion Weighing h1(mm) y (g/cm3) 18 1 19 0.9 21 0.8 24 0.7 Part No.: Art.-Nr.: 494.5210.020 494.5211.024 494.2109.018 233 Technical data Standard magnetic float switches Electrical data Changeover contact/normally-closed contact/normally-open contact K 250 V AC/DC 0.5 A 30 VA Changeover contact/normally-closed contact/normally-open contact L 250 V AC/DC 1A 60 VA Container connection options Flange enclosures RD 120 mm Flange enclosures RD 77 mm Flange enclosures RD 165 mm Flange enclosures RD 185 mm Cable gland PG 9 Cable gland R3/8'' Cable gland R1/5'' with plug connection DIN 43650 Oval flange 75 x 50 mm with plug-in connec. DIN43650 Flange enclosures RD 120 mm Flange enclosures RD 77 mm Flange enclosures RD 165 mm Flange enclosures RD 185 mm Cable gland Pg 9 Cable gland R3/8'' Cable gland R1/5'' with plug connection DIN 43650 Oval flange 75 x 50 mm with plug-in connec. DIN43650 Materials switching tube Stainless steel 1.4571 MS 63 PVC Stainless steel 1.4571 MS 63 PVC Float variants A / M / K Cylinder floats T / C / I Cylinder floats V/D Cylinder floats R / SCylinder floats N/P Cylinder floats E /F Ball floats B /O Ball floats G /H Ball floats Switching function Contact ID letter Rated voltage (max). Rated current (max.) Switching capacity (max.) Mechanical data RD RD RD RD RD RD RD RD 40 30 42 30 44 52 62 84 x 27 mm (POM) x 44 mm (PP) x 44 mm (NBR) x 44 mm (NBR) x 45 mm (stainless steel) mm (stainless steel) mm (stainless steel) mm (stainless steel) A / M / K Cylinder floats T / C / I Cylinder floats V/D Cylinder floats R / SCylinder floats N/P Cylinder floats E /F Ball floats B /O Ball floats G /H Ball floats RD RD RD RD RD RD RD RD 40 30 42 30 44 52 62 84 x 27 mm (POM) x 44 mm (PP) x 44 mm (NBR) x 44 mm (NBR) x 45 mm (stainless steel) mm (stainless steel) mm (stainless steel) mm (stainless steel) Ambient conditions Protection type (DIN 40050) Temperature range Pressure 234 IP 65 (up to IP 68, on request) -5°C to 60°C (from -30°C to 150°C, on request) 5 bar (up to 25 bar, on request) IP 65 (up to IP 68, on request) -5°C to 60°C (from -30°C to 150°C, on request) 5 bar (up to 25 bar, on request) Technical data Sensors Miniature magnetic float switches Electrical data Normally-closed contact / normally-open contact B 250 V AC/DC 0.5 A 10 VA Changeover contact/normally-closed contact/normally-open contact X 100 V AC/DC 0.3 A 3 VA Container connection options Cable Cable Cable Cable Cable Cable Cable Cable Materials switching tube Stainless steel 1.4571 PP PVC MS 63 Float variants K1 / Cylinder floats K2 / Cylinder floats K3 / Cylinder floats K4 / Cylinder floats N1 / Ball floats Switching function Contact ID letter Rated voltage (max). Rated current (max.) Switching capacity (max.) Mechanical data gland gland gland gland Pg 7 R1/8'' R3/8'' R3/8'' with plug gland gland gland gland Pg 7 R1/8'' R3/8'' R3/8'' with plug Stainless steel 1.4571 PP PVC MS 63 RD RD RD RD RD 25 25 20 23 30 x 20 mm (PP) x 20 mm (PVC) x 20 mm (NBR) x 25 mm (NBR) mm (stainless steel) K1 / Cylinder floats K2 / Cylinder floats K3 / Cylinder floats K4 / Cylinder floats N1 / Ball floats RD RD RD RD RD 25 25 20 23 30 x 20 mm (PP) x 20 mm (PVC) x 20 mm (NBR) x 25 mm (NBR) mm (stainless steel) Ambient conditions Protection type (DIN 40050) Temperature range Pressure IP 65 (up to IP 68, on request) -5°C to 60°C (from -30°C to 150°C, on request) 5 bar (up to 15 bar, on request) IP 65 (up to IP 68, on request) -5°C to 60°C (from -30°C to 150°C, on request) 5 bar (up to 15 bar, on request) 235 Technical data Adjustable magnetic float switches Electrical data Contact ID letter Switching module type Part No. Switching function Rated voltage (max). Rated current (max.) Switching capacity (max.) P REEDK. KPL. F. MA 491.0007.069 Normally-open contact / normally-closed contact 250 V AC/DC 5A 250 VA (bi) L REEDK. KPL. F. MA 491.6007.075 Changeover contact 250 V AC/DC 1A 60 VA (bi) Mechanical data Container connection options Flange DN 50 (PVC / stainless steel) Flange DN 65 (PVC / stainless steel) Cable gland R1.5'' (PVC / stainless steel) Cable gland R2'' (PVC / stainless steel) Flange encl. RD 120 mm (with gush protect. possible) Flange DN 50 (PVC / stainless steel) Flange DN 65 (PVC / stainless steel) Cable gland R1.5'' (PVC / stainless steel) Cable gland R2'' (PVC / stainless steel) Flange encl. RD 120 mm (with gush protect. possible) Materials switching tube Stainless steel 1.4571 MS 63 PVC Stainless steel 1.4571 MS 63 PVC Float variants N / PCylinder floats RD 52 x 55 mm (stainless steel) V / D / L Cylinder floats RD 52 x 55 mm (PVC) N / PCylinder floats RD 52 x 55 mm (stainless steel) V / D / L Cylinder floats RD 52 x 55 mm (PVC) IP 65 (up to IP 68, on request) -5°C to 60°C (from -30°C to 150°C, on request) 5 bar (up to 15 bar, on request) IP 65 (up to IP 68, on request) -5°C to 60°C (from -30°C to 150°C, on request) 5 bar (up to 15 bar, on request) Ambient conditions Protection class (DIN 40050) Temperature range Pressure 236 Technical data Chemical reistance of float and switching tube material at +20 °C Conc. in % 100 10 10 85 10 100 100 100 100 100 100 10 100 10 100 – 100 10 10 10 80 20 90 10 – 5 10 1 10 10 100 10 100 10 10 10 10 40 10 10 100 5 65 10 10 2 100 10 98 2 1 100 100 – 10 POM + / / + + / O + / + + / + + + / / O O + O + + / / / / + / / U + + / + + / / U + / / U U U U + + U / + + O / / PP + + + + + + O + U U U + O + + + U + + + + + + + + + + + / + U + + + + + + O + + + + U O + + U + O + + U O + + NBR U + + U U U U U U + O + U + U U U U + U U + + + + O + O + + U O + U + + + U U O + + U U U U U + U + + U U + + PVC U + + + O U U / U + U + U + U O U + + + + + + + U + + + + + O + + O + + + + + + + O + + + + U + O + + O U + + MS63 + U U U U O + + / + + + / U / U + U U U U O + / / U / / U U / O + U O O + O / U U U U U U U + U U O + + O O U 1.4571 + + + + + + + + + + + + + + + + + + U + + + + + + + + + + + + + + + + + + O + + + + + + U U + + + + + + + + + + = Resistant The material remains fully resistant to the medium or is only minimally affected. The effect of pressure and temperature changes on the materials must be taken into account. O = Resistant with limitations The material is affected by the medium; sealing compounds well up. If concentration, pressure, temperature, durability and other influential factors are restricted, application may be possible. U = Non-resistant The material may not be used in the specified medium or at the given temperature, unless under very clearly defined preconditions. / = no data availabe 237 Sensors Chemical substance Acetone Aluminium sulphate Aluminium chloride Formic acid Ammonia Aniline Ethyl acetate Sulphuric ether Ethylene chloride Petrol Benzene Boracic acid Butyl acetate Calcium chloride Chlorobenzene Chlorine water Chloroform Chromic acid Iron dichloride Acetic acid Acetic acid Formaldehyde Glycerine Urea Tincture of iodine Potassium bichromate Potassium nitrate Potassium perman. Bluestone Magnesium chloride Methylene chloride Lactic acid Mineral oil Sodium bisulphite Soda ash Sodium chloride Sodium sulphate Oxalic acid Phenolic aqueous Phosphoric acid Mercury Mercuric chloride Nitric acid Nitric acid Hydrochloric acid Hydrochloric acid Carbon disulphide Sulphuric acid Sulphuric acid Hydrogen sulphide Soap solution Carbon tetrachloride Trichloroethylene Wine Zinc chloride FAX Order form and questionnaire for magnetic float switches Page __________ from _________ Date: ________________________ Standard tube diameter 12 mm Adress: Sender: Company: Customer No.: Bernstein AG Tieloser Weg 6 D-32457 Porta Westfalica Contact: Department: Phone: +49-(0)5 71/7 93-0 Street: Fax: +49-(0)5 71/7 93-5 55 Town: Phone: Fax: Type Position O Enquiry _____ pieces O Order _____ pieces _____| _____| _____| _____| _____| _____| _____| _____| _____| _____| _____| _____| _____ 1 2 3 4 5 6 7 8 9 10 11 12 13 Operational environment: Pressure: ______ bar Temperature: __________°C Container dimens.: ______mm Medium: _____________ Cable length: ______m Separate contact type O Mounting options: O from above O from below O lateral Switching function (fulling level) Other comments: S = Normally-open Ö = Normally-closed U = change over 238