pdf

OSRAM
DRAGONeye G2
Technical Information
Benefits
 Compact high-flux LED-minispot
 Doubled flux compared to G1
 Very long lifetimes of 70 000 hours
 Integrated heat-sink and 15° optics
 IP65 rating for demanding outdoor applications
Applications
 Shop
- Cabinet & Shelf
 Hospitality
- Restaurant & Hotel
 Architectural
- robust outdoor minispot
Technical Operating Data
Product
current typ. voltage
[mA]
[V]
power
[W]
radiance
angle [°]
CCT
[K]
typ. lum.
flux [lm]
typ. lum.
intensity
[cd]
CRI
[Ra]
typ.
efficacy
[lm/W]
DE1-W4F-830-G2
350
3.1
1.1
15
3000
88
1080
>80
80
DE1-W4F-850-G2
350
3.1
1.1
15
5000
106
1300
>80
96
Product
max.
current
[mA]
min.
voltage
[V]
max.
max.
voltage power [W]
[V]
DE1-W4F-830-G2
500
2.8
3.5
1.75
DE1-W4F-850-G2
500
2.8
3.5
1.75
ESD
protection
Tc [°C]
IP rating L70B50 @
Ta=25°C
[h]
contact 4kV
air 8kV
90
65
70000
90
65
70000
All Data are related to the entire module
Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily
correspond to the actual parameters of each single product which could differ from the typical data
Technical Features
 Module ready to use with two cables:
 Max. tc temperature of 90oC (see IEC/PAS 62717)
- red cable (+ pole)
 L70B50 >=70,000 hours at Ta=25oC
- black cable (- pole)
 Energy efficiency class: A++
 Cable length 500 mm, cable Ø 1.6 mm/AWG 22
 Heat sink and lens-optics integrated
 Best efficacy in combination with OSRAM
OPTOTRONIC® constant current control gears
 IP65 for outdoor use
 Modul efficacy up to 96 lm/W
DRAGONeye G2 – 09.06.2014
Page 1
OSRAM
Minimum and Maximum Ratings
Product
operating temperature
storage temperature
ambient temperature
max. current
at tc-point [C°]*
[C°]*
range [C°]*
[mA]*
max. reverse
voltage [V]*
DE1-W4F-830-G2
-25 … 90
-25 … 85
-25 … 55
500
0
DE1-W4F-850-G2
-25 … 90
-25 … 85
-25 … 55
500
0
*) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module.
Exceeding maximum ratings for operating current will cause hazardous overload and will likely destroy the LED Module.
The temperature of the LED module must be measured at the tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature
sensitive label. For exact location of the tc-point see drawing below.
Dimensions & Mechanical data
Dimension (mm)
Ø23
Mounting
M10 thread included
Optics
PC lens
Weight
8 grams
DRAGONeye G2 – 09.06.2014
Page 2
OSRAM
Standard Compliance
Safety
EN 62031, IEC 60598-1, UL 8750
EMC
EN 55015, EN 61547
Eye Security
EN 62471
Ingress Production
Dry Location, IP 20
Environment
RoHS
Safety Information
 The LED module itself and all its components must not be mechanically stressed.
 Assembly must not damage or destroy conducting paths on the circuit board.
 To avoid mechanical damage to the connecting cables, the module should be attached securely to the intended
substrate. Heavy vibration should be avoided.
In order to drive OSRAM LED-Modules safely, it is absolutely necessary to operate them with an electronically
stabilised power supply protecting against short circuits, overload and overheating.
To also ease the luminaire/installation approval, electronic control gear for LED or LED modules should carry the CE mark
and be ENEC certified. The declarations of conformity must include the following standards:
CE: EC 61347-2-13, EN 55015, IEC 61547 and IEC 61000-3-2 - ENEC: 61347-2-13 and IEC/EN 62384.
Also check for the mark of an independent authorized certification institute.
Please see the relevant brochure for more detailed information (see "Related and Further Information").
OSRAM OPTOTRONIC® electronic control gear complies to all relevant standards and guarantees safe operation.
 Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety
standards. Only qualified personnel should be allowed to perform installations.
 Correct electrical polarity needs to be obsered. Wrong polarity will destory the module and will result in no light
emission.
 Pay attention to standard ESD precautions when installing the module.
 The module, as manufactured, has no conformal coating and therefore offers no inherent protection against corrosion.
 Damage by corrosion will not be honored as a materials defect claim. It is the user's responsibility to provide suitable
protection against corrosive agents such as moisture and condensation and other harmful elements.
 Pay attention not to exceed the maximum operation temperature at tc point when the modules are used in enclosed
environment.
DRAGONeye G2 – 09.06.2014
Page 3
OSRAM
Ordering Guide
Product Name
Product Code
DRAGONeye G2 DE1-W4F-830-G2
Product Number :
Product Number:
Piece per box
single product (EAN10) shipping box (EAN40)
4052899043053
4052899043077
264
DRAGONeye G2 DE1-W4F-850-G2
4052899042872
4052899042896
264
Sales and Technical Support
OSRAM GmbH
Marcel-Breuer-Straße 6
80807 Munich, Germany
www.osram.com
+49.89.6213-0 (Headquarter)
+49.89.6213-6000 (Customer-Service-Center)
DRAGONeye G2 – 09.06.2014
Sales and technical support is given by the local
OSRAM subsidiaries.
On the OSRAM website all subsidiaries are lis-ted
with complete address and phone numbers.
Page 4