OSRAM PrevaLED® COIN 111 AC PRELIMINARY Technical Information Product features Integrated driver, heat sink and lens optics Fits in most existing R111 traditinoal luminaires Narrow beam angles, 24o and 40o LED replacement up to HID 35W Flexibility through 2 lumen packages and 2 CCTs Benefits Easy & fast design-in for luminaire manufacturers Turn-key solution for projects Applications For Spot & Track-light in: Chain stores, Retail shops Shopping malls Exhibition halls Museums Technical Operating Data Product Input Voltage [Vac] Nominal Radiance Color Nominal Lum. Power Angle [°] Temp. [K] Flux [lm] Intensity [W] [cd] Typ. CRI [Ra] Efficacy [lm/W] PL-CN111AC-G1 1200-830 24 230V 220-240 15.5 24 3000 1250 4350 83 81 PL-CN111AC-G1 1200-840 24 230V 220-240 15.5 24 4000 PL-CN111AC-G1 1200-830 40 230V 220-240 15.5 40 3000 1350 4700 83 87 1250 2250 83 PL-CN111AC-G1 1200-840 40 230V 220-240 15.5 40 81 4000 1350 2400 83 PL-CN111AC-G1 1800-830 24 230V 220-240 22.5 87 24 3000 1850 6450 83 PL-CN111AC-G1 1800-840 24 230V 220-240 82 22.5 24 4000 1950 6800 83 PL-CN111AC-G1 1800-830 40 230V 87 220-240 22.5 40 3000 1850 3300 83 82 220-240 22.5 40 4000 1950 3500 83 PL-CN111AC-G1 1800-840 40 230V 87 All Data are related to the entire module (Testing at steady status. Ta=25oC ± 5oC. Testing current tolerance: ±5%) Due to the special conditions of the manufacturing processes of LED the typical data of technical parameters can only reflect statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ from the typical data Technical Features Module ready to use with two cables Color tolerance: <MacAdam 4 SDCM Cable length 500 mm, cable Ø 2.15 mm Max. tc temperature of 80oC (see IEC/PAS 62717) Color Rendering index CRI (Ra) typ. 83 L70B50 >= 35,000 hours at tp=68oC Light engine efficacy up to 87 lm/W including driver PrevaLED® COIN 50 – 18.08.2013 Page 1 OSRAM Minimum and Maximum Ratings Product Operating Temperature Storage Temperature At tc-Point [C°]* [C°]* Input AC voltage range PL-CN111AC-G1 1200-830 24 -20 … 80 -40 … 80 198 - 264 PL-CN111AC-G1 1200-840 24 -20 … 80 -40 … 80 198 - 264 PL-CN111AC-G1 1200-830 40 -20 … 80 -40 … 80 198 - 264 PL-CN111AC-G1 1200-840 40 -20 … 80 -40 … 80 198 - 264 PL-CN111AC-G1 1800-830 24 -20 … 80 -40 … 80 198 - 264 PL-CN111AC-G1 1800-840 24 -20 … 80 -40 … 80 198 - 264 PL-CN111AC-G1 1800-830 40 -20 … 80 -40 … 80 198 - 264 PL-CN111AC-G1 1800-840 40 -20 … 80 -40 … 80 198 - 264 *) Exceeding maximum ratings for operating and storage temperature will reduce expected life time or destroy the LED Module. Exceeding maximum ratings for operating current will cause hazardous overload and will likely destroy the LED Module. The temperature of the LED module must be measured at the tc-point according to EN60598-1 in a thermally constant status with a temperature sensor or a temperature sensitive label. For exact location of the tc-point see drawing below. Dimensions & Mechanical data Dimension (mm) Ø111 x 49.5 (H) Mounting AR111 similar Optics PC lens Weight 340 grams PrevaLED® COIN 50 – 18.08.2013 Page 2 OSRAM Standard Compliance Safety EN 62031, IEC 60598-1, UL 8750 EMC EN 55015, EN 61547 Eye Security EN 62471 Ingress Production Dry Location, IP 20 Environment RoHS Electrical Operating Conditions PrevaLED® COIN 50 – 18.08.2013 Page 3 OSRAM Safety Information The LED module itself and all its components must not be mechanically stressed. Assembly must not damage or destroy conducting paths on the circuit board. To avoid mechanical damage to the connecting cables, the module should be attached securely to the intended substrate. Heavy vibration should be avoided. Installation of LED modules (with power supplies) needs to be made with regard to all applicable electrical and safety standards. Only qualified personnel should be allowed to perform installations. Pay attention to standard ESD precautions when installing the module. Damage by corrosion will not be honored as a materials defect claim. It is the user's responsibility to provide suitable protection against corrosive agents such as moisture and condensation and other harmful elements. If the IP rating of the fixture should be higher than IP20, the design of the housing should be according to the IP standards in the application. Pay attention not to exceed the maximum operation temperature at tc point when the modules are used in enclosed environment. PrevaLED® COIN 50 – 18.08.2013 Page 4 OSRAM Ordering Guide Product Name Product Code Product Number (EAN10) Product Number (EAN40) Piece per box PrevaLED® COIN 111 AC PL-CN111AC-G1 1200-830 24 4052899165533 4052899165540 12 PrevaLED® COIN 111 AC PL-CN111AC-G1 1200-840 24 4052899165557 4052899165564 12 PrevaLED® COIN 111 AC PL-CN111AC-G1 1800-830 24 4052899165571 4052899165588 12 PrevaLED® COIN 111 AC PL-CN111AC-G1 1800-840 24 4052899165595 4052899165601 12 PrevaLED® COIN 111 AC PL-CN111AC-G1 1200-830 40 4052899165618 4052899165625 12 PrevaLED® COIN 111 AC PL-CN111AC-G1 1200-840 40 4052899165632 4052899165649 12 PrevaLED® COIN 111 AC PL-CN111AC-G1 1800-830 40 4052899165656 4052899165663 12 PrevaLED® COIN 111 AC PL-CN111AC-G1 1800-840 40 4052899165670 4052899165687 12 Sales and Technical Support OSRAM Asia Pacific 30th Floor, China Resource Building, 26 Harbour Road, Wanchai, Hong Kong Sales and technical support is given by the local OSRAM subsidiaries. Complete subsidiaries listing is available at OSRAM homepage. +852 3652 5678 www.osram.com PrevaLED® COIN 50 – 18.08.2013 Page 5