PrevaLED® Core AC G1
www.osram.com/prevaled-core
PrevaLED® Core AC G1
Benefits

Connect directly to 220-240 V AC for class 1
luminaire; no need for external driver

Smaller, slimmer, simpler, cheaper luminaires
possible

Simplified logistics as no external driver or special
cables are required

Safety: CE, protective cover glass, reversible thermal
shutdown

Easy to integrate as engine is compatible with Zhaga
book 3 heatsink and reflector; Poke-in cables

Uniform Chip-On-Board technology with great
homogeneity / No additional diffuser required
Applications

Spotlighting in retail stores

Down- and wall lighting in offices, corridors, meeting rooms, workplaces

Decorative and functional lighting in the hospitality industry
Technical operating data
Initial
Mac
Adam
step
Life time
(L70/B30)
[h] 1)
Tc
max
[°] 2)
110
<3
> 50.000
80
110
<3
> 50.000
80
110
<3
> 50.000
80
83
110
<3
> 50.000
80
83
110
<3
> 50.000
80
83
110
<3
> 50.000
80
Light
Emitting
Surface
category
Lum.
flux
typ. 1)
[lm]
System
power
typ. 1)
[W]
System
efficiency
typ.1)
[lm/W]
CCT
typ.
[K]
CRI
typ.
PL-CORE AC-800-827-G1
LES 13,5
800
14,0
59
2700
83
PL-CORE AC-800-830-G1
LES 13,5
800
13,1
60
3000
83
PL-CORE AC-800-840-G1
LES 13,5
800
12,6
62
4000
83
PL-CORE AC-2000-827-G1
LES 19
2000
26,2
76
2700
PL-CORE AC-2000-830-G1
LES 19
2000
25,7
78
3000
PL-CORE AC-2000-840-G1
LES 19
2000
24,4
82
4000
Product
Viewing
angle
typ.
[°]
Technical Features

LED light engine with integrated driver

Power factor: >0.9

Light emitting surface, diameter (50mm) and mounting

Input Voltage: 220 – 240 Vac 50-60Hz
holes positioning according to Zhaga Book 3

Module mounting using M3 screws

Poke-in wire connection (no special connector required)

Storage temperature: -20°C to 85°C

Reversible thermal shutdown

Ambient Temperature: 0°C to 40°C
_________________________________________________________________________________________________________________
LEP Core AC – 2013-06-20
Page 1 of 3
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
PrevaLED® Core AC
www.osram.com/prevaled-core
Optical characteristics
Product
Light
Emitting
Surface
category
Light
Emitting
Surface real
(diameter in
Optical
Contact Area
category
Lumen. flux,
max.1)
Lumen. flux,
min.1)
Luminous
Flux category
mm)
PL-CORE AC-800-827-G1
LES 13,5
13
B / 19
940
720
C008
PL-CORE AC-800-830-G1
LES 13,5
13
B / 19
940
720
C008
PL-CORE AC-800-840-G1
LES 13,5
13
B / 19
940
720
C008
PL-CORE AC-2000-827-G1
LES 19
19
C / 29
2300
1800
C020
PL-CORE AC-2000-830-G1
LES 19
19
C / 29
2300
1800
C020
PL-CORE AC-2000-840-G1
LES 19
19
C / 29
2300
1800
C020
Thermal characteristics and driver designation
Product
Maximum total thermal power
Pth,max (W)
PL-CORE AC-800-827-G1
13,1
PL-CORE AC-800-830-G1
12,8
PL-CORE AC-800-840-G1
11,6
PL-CORE AC-2000-827-G1
22,6
PL-CORE AC-2000-830-G1
22,0
PL-CORE AC-2000-840-G1
20,2
Case temperature
Please measure the case temperature for PrevaLED®
Core AC in the center of the back side of the light
engine. This can be achieved by a thin, milled channel
or a drilled hole.
Tp and Tr measurement points are also located at t c
point
tc
General dimensions
General dimensions of 800 and
2000
lumen
engine
are
identical. Detailed technical
drawings are available through
OSRAM sales representative.
_________________________________________________________________________________________________________________
LEP Core AC – 2013-06-20
Page 2 of 3
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.
PrevaLED® Core AC
www.osram.com/prevaled-core
Safety Information

The LED module itself and all its components must not be mechanically stressed.

When handling the module without use of mountain screws avoid excessive force on the cover as it may be
separated from the PCB.

Installation of LED modules needs to be made with regard to all applicable electrical and safety standards.

Do not remove the cover or the glass from the module

PrevaLED Core AC is suitable for luminaire class 1, connection of the earth is mandatory to respect safety standards

Only qualified personnel should be allowed to perform installations.

All PrevaLED® Core AC 800, 2000lm have to be classified according to EN 62471-1 in risk group 1 (RG 1). In RG 1, in
absence of UV and IR radiation, no labeling is required (TR 62471-2).
Assembly Information

Please ensure sufficient cooling of light engine

The engine is suitable for wires with AWG 18-24 (0,2mm2- 0,75mm2).

The module has to be mounted to a sufficient heat sink with M3 screws.

For optimum cooling a thermally conducting layer should be applied between module and heat sink.

Further details and recommendation for mounting can be found in the application guide.
Production information

Due to the special conditions of the manufacturing processes of LED the data of technical parameters can only reflect
statistical figures and do not necessarily correspond to the actual parameters of each single product which could differ
from the typical data.

Exceeding maximum rating for operation and storage will reduce expected lifetime or destroy the module

1)

2)

3)
EAN: Ordering number per single module

4)
S-Unit: Modules per shipping unit
for Tp = Tr = 65°C
Tc according to IEC 62031 is the highest permissible temperature which may occur at the center backside on the LED
Module under normal operating conditions
Ordering codes
Product name –
NON VDE / ENEC
EAN
3)
Product name –
VDE / ENEC
EAN
3)
S-Unit
LEP-800-827-C-AC
4008321849595
PL-CORE AC-800-827-G1
4052899050648
50
LEP-800-830-C-AC
4008321849441
PL-CORE AC-800-830-G1
4052899050662
50
LEP-800-840-C-AC
4008321849472
PL-CORE AC-800-840-G1
4052899050686
50
LEP-2000-827-C-AC
4008321849502
PL-CORE AC-2000-827-G1
4052899050709
50
LEP-2000-830-C-AC
4008321849533
PL-CORE AC-2000-830-G1
4052899050723
50
LEP-2000-840-C-AC
4008321849564
PL-CORE AC-2000-840-G1
4052899050747
50
4)
Sales and Technical Support
OSRAM AG
Hellabrunner Strasse 1
D - 81536 München
Deutschland
www.osram.com
+49 89 6213-0
3 year warranty. For more information please refer to our website
For commercial support please contact your local sales representative
For technical support please contact [email protected]
On our homepage all OSRAM subsidiaries are listed with complete address
and phone numbers.
_________________________________________________________________________________________________________________
LEP Core AC – 2013-06-20
Page 3 of 3
Note: Typical performance data are subject to change without any further notice, particularly as LED technology evolves.