C HiTESTER 3506, 3505 C HiTESTER 3504-60, 3504-50, 3504-40 Electronic measuring instruments For Low Capacitance C HiTESTER 3506 Measures at 1 kHz and 1 MHz C HiTESTER 3505 Measures at 1 kHz, 100 kHz and 1 MHz For High Capacitance MLCCs C HiTESTERs 3504 -60, 3504 -50 and 3504 -40 Measures at 120 Hz and 1 kHz Ideal C meters for sorting and testing High-Speed Measurements Measurement intervals as fast as 2 ms Specifically, the 3504 Series performs constant-voltage measurements of high-capacitance MLCCs in 2 ms. High Accuracy Models 3505 and 3506 have greatly improved repeatability accuracy for very low capacitance measurements. Contact-Checking Functions Use Low-C Reject and Detection Level Monitoring functions to verify contact integrity between measurement electrodes and objects to be measured. Model 3504-60 provides four-terminal contact checking. 1 C HiTESTER Sort values with the Bin function Measurements as fast as 2 ms Common Features of Models 3506, 3505, 3504-60, 3504-50 and 3504-40 n C-Meter measurement frequencies comply with JIS C 5101-1 Capacitor Type C Range Measurement Frequency [Hz] Indicates recommended frequency • 100k C ≤ 1000 pF Non-Electrolytic Electrolytic - 1M 1k 1000 pF < C ≤ 10 μF 10 μF < C Supporting Models 3506(*1) 3505 3504-60 3504-50 3504-40 3511-50 (for ref.) 120 120 (*1) 100 kHz not available in Model 3506 n BIN function*1 C measurement values can be classified into up to 14*2 ranks for easy sorting. *1 Available in Models 3504-60 and 3504-50, but not in Model 3504-40. *2 Models 3506 and 3505 support up to 13 ranks. n Comparator function Upper and lower limits can be specified for first (C) and second (D) parameters. Evaluation results can be indicated by beeper, LED indicators and external output, with the setting values always displayed. n Memory function Measurement data is stored in the instrument and can be downloaded via GP-IB or RS-232C. 3505, and 3506 .......................... 1,000 measurements 3504-60, 3504-50 and 3504-40 .... 32,000 measurements n Intuitive operation with LED indicators Simply select the desired operation on the front panel. The current measurement configuration settings are indicated by LEDs so you can check your settings at a glance. n Trigger-synchronous output The measurement signal is applied to the test sample only when a measurement trigger is applied. Because large current does not flow when making and breaking contact with the sample, contact point wear is minimized. n Stores 99*3 measurement configurations Store up to 99 sets of measurement configuration settings for quick recall when switching test sample types on lines with many repeating measurements. Any measurement configuration can be recalled by EXT I/O. *3 Models 3506 and 3505 store up to 70 measurement configurations. n Contact-checking functions included Detect contact errors during measurement. Improve yield rates by separately managing samples that exhibit contact errors. 2 n High-speed measurements as fast as 2 ms (1 ms for analog measurements) High-speed testing such as with taping machines is supported by the 2 ms minimum measurement time (except FAST 120 Hz measurements). Select from FAST, NORMAL and SLOW measurement speeds. 3506, 3505 Measurement Speed Measurement Frequency Output Signal FAST NORMAL SLOW INDEX 1.1 ms 4.1 ms 13.3 ms EOM 2 ms 5 ms 14 ms 1 kHz 100 kHz 1 MHz 3504 -60, 3504 -50, 3504 -40 Measurement Speed Measurement Frequency Output Signal FAST NORMAL SLOW INDEX 8.3 ms 33.3 ms 133.3 ms EOM 10 ms 37.5 ms 146 ms INDEX 1 ms 4 ms 24 ms EOM 2 ms 5.5 ms 29.5 ms 120 Hz 1 kHz Equipped with standard EXT I/O, RS-232C, and GP-IB* EXT I/O RS-232C * GP-IB is not available on Model 3504-40. GP-IB Voltage selector Voltage selector EXT I/O GP-IB RS-232C * Model 3504-40 does not include a GP-IB interface. C HiTESTER 3506, 3505 n EXT I/O Triggering and loading of measurement conditions can be controlled externally. Capable of external output of comparator results, BIN measurement results, and endof-measurement signals, these HiTESTERs support full interfacing with automated devices. C HiTESTER 3504-60, 3504-50, 3504-40 n EXT I/O Timing Chart C1 Chuck C1 End-of-Measurement C2 Transport C2 Chuck TRIG 1 ms* EXT I/O Features • Inputs INDEX • Outputs • Internal DC power output (+5 V) • External DC power input (+5 to 24 V, • Comparator result output (first and may be supplied from external device) second parameters, and ANDed • External trigger signal results) • P a n e l n u m b e r ( M e a s u re m e n t • Bin measurement judgment output configuration) selection • Analog End-of-Measurement signal • Panel-number-valid signal • End-of-Measurement signal • Calibration • Error message output n RS-232C and GP-IB interface* Except for turning the instrument's power on and off, all HiTESTER functions can be controlled from a computer. This facilitates efficient data handling when controlling or processing data in batches on a computer or when setting instrument processing or measurement conditions. * GP-IB is not available on Model 3504-40. C1 C1 Analog End-of-Measurement Analog Measurement 2 ms* C1 Measuring EOM HI, IN, LO, BIN C0 Judgment C1 End-of-Measurement C1 Judgment * Measurement Speed: FAST used for example. Not applicable for 120 Hz measurements. RS-232C interface • Transfer method: Start-stop transfer • Data length: 8 bits • Stop bit: 1 bit • Transfer speed: 9600, 19200 bps • Parity: None • Delimiter: CR+LF, CR GP-IB interface • IEEE-488-2 1987 common commands (mandatory) can be used • Conformance standard: IEEE-488.1 1987 • Reference standard: IEEE-488.2 1987 3 C HiTESTER 3506, 3505 Measure low-magnitude capacitors with high accuracy •Measurement parameters and frequency ranges Measurement Frequencies Range of Measurements (C, D) 120 Hz C: 0.000 fF to 15.0000 µF 3506 D: 0.00001 to 1.99999 1 kHz C: 0.000 fF to 15.0000 µF 1 MHz - - 3505 D: 0.00001 to 1.99999 100 kHz - Features of Models 3506 and 3505 C HiTESTERs n Enhanced repeat-measurement accuracy 3505 NORMAL (5 ms) Previous model FAST (5 ms) 100 60 40 20 80 0 60 −0.02% −0.01% −0.00% 0.01% 0.02% Capacitance Measurement Repeatability Accuracy 40 20 0 .3 2 −0 5% .2 7 −0 5% .2 2 −0 5% .1 7 −0 5% .1 2 −0 5% .0 7 −0 5% .0 25 0. % 02 5 0. % 07 5 0. % 12 5 0. % 17 5% 0. 22 5 0. % 27 5 0. % 32 5% Repetitions A self-calibration function minimizes variations in measurement values due to changes in ambient temperature. In addition, the cable-length-compensation function minimizes measurement errors when the measurement cable is extended from 1 to 2 meters (using 1.5D-2V cable). 120 −0 n Enhanced absolute accuracy 3505 NORMAL (EOM = 5 ms) Previous model FAST (EOM = 5 ms) Repetitions 80 The lowest capacitance range of Models 3506 and 3505 is 220 fF* (at 1 MHz), with greatly improved repeatability accuracy for very low-capacitance measurements. * 1 fF (femtofarad) = 10-15 F Capacitance Measurement Repeatability Accuracy Measuring 1 pF (at 1 MHz, 1 V) n Enhanced contact-checking function Contact errors while measuring can be detected by the Chatter Detection function, Low-C Reject function, Current Detection Circuit Monitoring function and the Applied Voltage Value Monitoring function. Yield rates are improved by judging measurement-object contact errors as ERR instead of FAIL. Extremely low capacitance judged as Low C (ERR) Chatter Chatter Faulty Contact Contact Condition Normal Contact Pass / Fail Judgment Chatter Monitoring Interval INDEX Low-C Reject Function Analog Measurement Chatter Detection Function Chatter Detection Function Unstable Voltage and Current While Measuring ➞ ERR Chatter Detection Function Stable Voltage and Current While Measuring ➞ Pass / Fail Judgment 4 C HiTESTER 3506, 3505 n Specifications Measured parameters C (Capacitance), D (dissipation factor tan δ), Q (1/tan δ) Measurement frequencies 1 kHz, 100 kHz (only Model 3505) and 1 MHz Accuracy: ±0.01% or better Frequency shift: 1 MHz ±1%, ±2% Measurement signal level Open-circuit terminal voltage: 500 mV or 1 V Signal level accuracy: ±10% ±5 mV Output resistance: Approx. 1Ω (@1 kHz in 2.2 μF and higher ranges; @100 kHz in the 22 nF and higher ranges), approx. 20 Ω (in ranges other than the above) C: 0.000 fF to 15.0000 μF Range of measureable D: 0.00001 to 1.99999 values Q: 0.0 to 19999.9 Equivalent circuit mode Series-Parallel Equivalent Circuit mode (Auto/Manual) Compensation Open- and short-circuit compensation, load and cable length compensation, and self calibration Trigger-synchronous output function Functions to inhibit measurement voltage except while actually measuring Key-lock function Settings can be made and cancelled by front panel keys BIN measurement C: 13 ranks, D-NG, OUT OF BINS, Absolute value setting, ∆ setting, ∆% setting Comparator C: HI, IN, LO; D(Q): HI, IN, LO Absolute value setting, ∆ setting, ∆% setting Panel save and load 70 setting configurations can be stored Load method: key operation or external I/O Representative value: 2 ms (FAST) (Actual measurement time depends on measurement configuration settings) Audible beeper Measurement time Setting the buzzer for comparator judgment results (IN or NG) to ON or OFF is possible Interface RS-232C, GP-IB and EXT I/O (included as standard) Measurement speed FAST, NORMAL and SLOW Printer function Measurement values can be printed (requires Model 9442 or 9444 cable) Averaging function 1 to 256 Display device LEDs (on/off) Low-C Reject function Bad Contact Detection (open circuit between terminals) Operating temperature and humidity 0 to 40°C, 80% RH or less (non-condensating) Chatter Detection function Bad Contact Detection (chatter) Storage temperature and humidity -10 to 55°C, 80% RH or less (non-condensating) Current Detection Circuit Monitoring function A measurement signal fault is detected when external noise causes measurement levels to be out of tolerance for the measurement range. Applied Voltage Value An error is detected when voltage monitored across a test sample is outside of the judgment standard. Monitoring function Operating environment Indoors, to 2000 m ASL Selectable 100, 120, 220 or 240 V ±10%, 50/60 Hz Power supply Max. power consumption 40 VA Withstand voltage Power line to ground: 1.39 kV AC for 15 s Backup battery life Approx. 6 years Trigger function Internal and external triggers can be enabled Dimensions 0 to 9.999 s Approx. 260 W × 100 H × 298 D mm (exc. projections) Trigger Delay Approx. 4.8 kg Memory function Up to 1,000 measurement values can be stored in the instrument (Downloadable by GP-IB and RS-232C) Weight Applicable standards EMC: EN61326, EN61000-3-2, EN61000-3-3 Safety: EN61010-1 Supplied accessories Power Cord, Spare Fuse Measurement accuracy and range Temp. and humidity for guaranteed accuracy: 23°C ±5%, 80% RH or less (non-condensating) Warm-up time: 1 h, with open- and short-circuit compensation, and self calibration set to Auto n Measurement area: C: 0.001 fF to 15.0000 μF; D: 0.00001 to 1.99999 n Measurement accuracy Use the following equation to calculate the measurement accuracy. n Basic accuracy [Guaranteed accuracy: 6 months when D ≤ 0.1 D] C range Parameter 100 pF Measurement accuracy = basic accuracy × B × C × D × E 220 pF [B: Measurement signal level coefficient] 1 V: 1, 500 mV: 2 470 pF [C: Measurement speed coefficient] FAST: 1.5, NORMAL: 1.2, SLOW: 1 [D: Cable length coefficient] (using 1.5D-2V cable) 0 m: 1, 1 m: 1.5, 2 m: 2 [E: Temperature coefficient] 1+0.1× |t-23| t = operating temperature (°C) 1 nF 2.2 nF 4.7 nF 10 nF 22 nF 47 nF 100 nF 220 nF 470 nF 1 μF 2.2 μF 4.7 μF 10 μF C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D Accuracy 1 kHz 0.12%rdg+0.2%rdg×(Cr/Cx) 0.002+0.001×(Cr/Cx) 0.12%rdg+0.08%rdg×(Cr/Cx) 0.0012+0.0004×(Cr/Cx) 0.12%rdg+0.04%rdg×(Cr/Cx) 0.0012+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.0012+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.0012+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) C range Parameter 1 pF 2.2 pF 4.7 pF 10 pF 22 pF 47 pF 100 pF 220 pF 470 pF 1 nF 2.2 nF 4.7 nF 10 nF 22 nF 47 nF 100 nF C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D C D Accuracy 100 kHz (only Model 3505) 0.5%rdg+0.5%rdg×(Cr/Cx) 0.004+0.004×(Cr/Cx) 0.3%rdg+0.2%rdg×(Cr/Cx) 0.004+0.003×(Cr/Cx) 0.25%rdg+0.15%rdg×(Cr/Cx) 0.004+0.002×(Cr/Cx) 0.25%rdg+0.1%rdg×(Cr/Cx) 0.004+0.002×(Cr/Cx) 0.25%rdg+0.06%rdg×(Cr/Cx) 0.003+0.0015×(Cr/Cx) 0.25%rdg+0.06%rdg×(Cr/Cx) 0.0025+0.0015×(Cr/Cx) 0.15%rdg+0.06%rdg×(Cr/Cx) 0.0015+0.001×(Cr/Cx) 0.15%rdg+0.04%rdg×(Cr/Cx) 0.0015+0.0005×(Cr/Cx) 0.15%rdg+0.02%rdg×(Cr/Cx) 0.0015+0.0003×(Cr/Cx) 0.15%rdg+0.02%rdg×(Cr/Cx) 0.0015+0.0003×(Cr/Cx) 0.15%rdg+0.02%rdg×(Cr/Cx) 0.0015+0.0003×(Cr/Cx) 0.15%rdg+0.02%rdg×(Cr/Cx) 0.0015+0.0003×(Cr/Cx) 0.15%rdg+0.02%rdg×(Cr/Cx) 0.0015+0.0003×(Cr/Cx) 0.15%rdg+0.02%rdg×(Cr/Cx) 0.0015+0.0003×(Cr/Cx) 0.15%rdg+0.02%rdg×(Cr/Cx) 0.0015+0.0003×(Cr/Cx) 0.2%rdg+0.02%rdg×(Cr/Cx) 0.002+0.0003×(Cr/Cx) C range Parameter 220 fF 470 fF 1 pF 2.2 pF 4.7 pF 10 pF 22 pF 47 pF 100 pF 220 pF 470 pF 1 nF C D C D C D C D C D C D C D C D C D C D C D C D Accuracy 1 MHz 0.2%rdg+1%rdg×(Cr/Cx) 0.004+0.002×(Cr/Cx) 0.15%rdg+0.3%rdg×(Cr/Cx) 0.003+0.001×(Cr/Cx) 0.12%rdg+0.16%rdg×(Cr/Cx) 0.002+0.001×(Cr/Cx) 0.12%rdg+0.08%rdg×(Cr/Cx) 0.0012+0.0004×(Cr/Cx) 0.12%rdg+0.04%rdg×(Cr/Cx) 0.0012+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.0012+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) 0.12%rdg+0.02%rdg×(Cr/Cx) 0.001+0.0003×(Cr/Cx) [Cx : the electrical capacity of the sample / Cr : the electrical capacity of the measurement range] 5 C HiTESTER 3504-60, 3504-50 and 3504-40 Perform high-speed, constant-voltage testing even of high-capacitance MLCCs •Measurement parameters and frequency ranges Range of Measurements (C, D) Measurement Frequencies 120 Hz 1 kHz 100 kHz 1 MHz - - 3504-60 C: 0.9400 pF to 20.0000 mF 3504-50 D: 0.00001 to 1.99999 3504-40 •Functional differences between Models 3504 Constant-Voltage Measurement (CV) 100mV 500mV 1V -60, 3504-50 and 3504-40 Four-Terminal Interface Bin Contact Check Function Function RS-232C GP-IB EXT I/O 3504-60 3504-50 - - 3504-40 - - - - Features of Model 3504-60, 3504-50 and 3504-40 C HiTESTERs n Constant voltage measurement (CV) Constant measuring voltages of 1 V, 500 mV and 100 mV*1 are provided for voltage-dependent capacitance measurements. Measurement frequency is selectable from 120 Hz or 1 kHz. *1 100 mV in Model 3504-60 only. n Compatible with taping machine assemblies Model 3504 -40 provides the speed and good costperformance suitable for taping machine systems. n Four-Terminal Contact-Checking Function*2 Detect contact errors at all four measurement terminals, for highly reliable contact checking. *2 Model 3504-60. n Enhanced Contact-Checking Functions Contact errors can be detected while measuring by the Low-C Reject and Chatter Detection functions. Yield rates are improved by judging measurement object contact errors as ERR instead of FAIL. n Specifications Measured parameters C (capacitance), D (dissipation factor tan δ) 120 Hz or 1 kHz Measurement Accuracy: ±0.01% or better frequencies (1) Constant voltage mode: 100 mV*1, 500 mV and 1 V CV 1V measurement ranges: up to 70 μF range (1 kHz) up to 0.7 mF range (120 Hz) Measurement signal CV100 mV*1, CV 500 mV measurement ranges: up to 170 μF range (1 kHz) level up to 1.45 mF range (120 Hz) *1 Signal level accuracy: ±10% ±5 mV 100 mV in Model 3504-60 (2) Open terminal voltage mode: 100 mV*1, 500 mV and 1 V only Measurement range: Other than the above Output resistance: approx. 5Ω Signal level accuracy: ±10% ±5 mV Trigger-synchronous output function Key-lock function BIN measurement (Not available on the 3504-40) Memory function Comparator Panel save and load Range of measurable C: 0.9400 pF to 20.0000 mF D: 0.00001 to 1.99999 values Equivalent circuit mode Series/parallel equivalent-circuit mode (Auto/Manual) Audible beeper Measurement time Printer function Measurement speed Trigger function Trigger delay Compensation Averaging function Four-terminal contact-checking function* Nominal 2 ms (1 kHz, FAST) (The measurement time differs depending on the measurement frequency and measurement speed that are set.) FAST / NORMAL / SLOW Internal and external trigger sources can be selected. 0 to 9.999 s (at 0.001 s resolution) Open, Short, Load and Offset compensation, Self-calibrating 1 to 256 Detects contact anomalies (open state in four-terminal measurements) (* 3504 -60 only) Detects contact anomalies (open state in two-terminal Low-C Reject function measurements) Chatter Detection function Detects contact bounce (chatter) Interface Display device Operating temperature and humidity Storage temperature and humidity Operating environment Power supply Max. pewer consumption Withstand voltage Backup battery life Dimensions Weight Applicable standards Supplied accessories Function to apply a measurement signal only when performing measurement. The key lock can be set and cancelled by key operation on the front panel C; 14 ranks, D-NG, OUT OF BINS Absolute value setting, Δ% setting Up to 32,000 measurement values can be stored in the instrument (Downloadable by GP-IB and RS-232C) C: HI / IN / LO, D: HI / IN / LO Absolute value setting, Δ% setting Up to 99 sets of measurement conditions can be saved. Load method: Key operation, external I/O. The beeper can be set on or off according to the comparator evaluation result (“IN” or “NG”) and Bin decision result. Models 3504-50, 3504-60: RS-232C, GP-IB, EXT I/O (standard) Model 3504-40: RS-232C, EXT I/O (standard) Measurement values can be printed (requires Printer 9442 and optional Connection Cable 9444) LED 0 to 40°C, 80% RH or less (no condensation) -10 to 55°C, 80% RH or less (no condensation) Indoors, up to 2000 m ASL AC 100 V, 120 V, 220 V, or 240 V±10% (selectable), 50/60 Hz 110 VA max. Power line to ground, AC 1.69 kV, 15 sec. Approx. 6 years Approx. 260 (W) × 100 (H) × 220 (D) mm (excluding protrusions) Approx. 3.8 kg EMC: EN61326, EN61000-3-2, EN61000-3-3 Safety: EN61010-1 Power cord, spare fuse 6 C HiTESTER 3504-60, 3504-50 and 3504-40 Measurement accuracy and range Temp. and humidity for guaranteed accuracy: 23°C ±5%, 80% RH or less (non-condensating) Warm-up time: 1 h, with open- and short-circuit compensation n Measurement area: C: 0.9400 pF to 20.0000 mF; D: 0.00001 to 1.99999 n Measurement accuracy n Basic accuracy [Guaranteed accuracy: 6 months when D ≤ 0.1 D] Range No. Use the following equation to calculate the measurement accuracy. 1 Measurement accuracy = basic accuracy × B × C × D × E 2 [B: Measurement signal level coefficient] 1 at 1 V and at 500 mV, 1.5 at 100 mV 3 4 [C: Measurement speed coefficient] FAST: 1.5 NORMAL: 1.0 (at 1 kHz, 1 V), 1.2 (except at 1 kHz, 1 V) SLOW: 1 5 6 7 [D: Cable length coefficient] (using 1.5C-2V cable) 0 m: 1 1 m: 1 (at 1 kHz, 1 V) 1.5 (except at 1 kHz, 1 V) 8 [E: Temperature coefficient] 1+0.1× |t-23| t = operating temperature (°C) 10 9 C range 120 Hz 1 kHz Parameter C 200 pF 20 pF D C 2 nF 200 pF D C 20 nF 2 nF D C 200 nF 20 nF D C 2 μF 200 nF D C 20 μF 2 μF D C 200 μF 20 μF D C 0.7 mF(1V) 70 μF(1V) 1.45 mF(500 mV, 100 mV) 170 μF(500 mV, 100 mV) D C 2 mF 200 μF D C 20 mF 2 mF D Basic accuracy *1 120 Hz 1 kHz ±0.20%rdg.±300dgt. ±0.20%rdg.±300dgt. ±0.0120±2/CL ±0.0120±0.25/CL ±0.20%rdg.±60dgt. ±0.20%rdg.±60dgt. ±0.0020±2.2/CL ±0.0020±0.265/CL ±0.16%rdg.±20dgt. ±0.14%rdg.±20dgt. ±0.0036 ±0.0036 ±0.15%rdg.±15dgt. ±0.13%rdg.±15dgt. ±0.0020 ±0.0020 ±0.15%rdg.±15dgt. ±0.13%rdg.±15dgt. ±0.0016 ±0.0016 ±0.15%rdg.±15dgt. ±0.09%rdg.±10dgt. ±0.0020 ±0.0016 ±0.25%rdg.±20dgt. ±0.13%rdg.±15dgt. ±0.0035 ±0.0030 ±1.2%rdg.±50dgt. ±0.7%rdg.±40dgt. ±0.0060 ±0.0050 ±1.2%rdg.±50dgt. ±0.7%rdg.±40dgt. ±0.0060 ±0.0050 ±2.5%rdg.±50dgt. ±2.0%rdg.±40dgt. ±0.0200±0.008×CH ±0.0180±0.08×CH [CL: Capacitance of component (pF), CH: Capacitance of component (mF)] *1 Accuracy of range nos. 1 and 2 are not guaranteed at 100 mV measurement signal level. LCR meter for electrolytic capacitors LCR HiTESTER 3511-50 • High speed measurement: 5 ms (1 kHz) or 13 ms (120 Hz) • Built-in high-speed comparator function ideal for measuring at the production line • Source frequency: 120 Hz or 1 kHz • Print measurement values and judgment results with the optional Printer 9442 Measurement leads are not included. Purchase the appropriate lead option for your application separately. Resistance tester for continuity testing of 3 terminal capacitors RESISTANCE HiTESTER 3541 • Wide Measurement Range 0.1 μΩ (20 mΩ ranges) to 110.000 MΩ • High Speed & High Precision Measurements As fast as 0.6 ms with 70 ppm precision (in the 2 kΩ to 110 kΩ range) • Two types of Temperature Correction Correction by Pt sensor or Infrared Thermometer • Low-Power Measurement Function Essential for DCR measurements of chip inductors and connector contacts • Equipped with EXT I/O, GP-IB and RS-232C interfaces Easily integrates into automated production lines • Data Printing Print out measurement values and calculation results (with optional Printer 9670) CV operation ❍ ❍ ❍ ❍ ❍ ❍ ❍ ❍ ✕ ✕ 7 Options for a wide range of applications • For 3504-60, 3504-50 and 3504-40 FOUR-TERMINAL PROBE 9140 DC to 100 kHz TEST FIXTURE 9261 DC to 5 MHz * 9140, 9143, 9261 cable lengths are 1 m (39.37”). SMD TEST FIXTURE 9677 DC to 120 MHz Test sample dimensions: 3.5 ± 0.5 mm SMD TEST FIXTURE 9699 DC to 120 MHz Test sample dimensions: 1.0 to 4.0 mm wide, maximum 1.5 mm high PINCHER PROBE 9143 DC to 5 MHz • For 3506, 3505, 3504-60, 3504-50 and 3504-40 SMD TEST FIXTURE 9263 DC to 5 MHz Test sample dimensions: 1 to 10 mm TEST FIXTURE 9262 DC to 5 MHz PRINTER 9442 Measurement values, comparator results, and BIN measurement results can be printed out on the optional Printer 9442 via the standard RS-232C interface. This is convenient if you want to attach inspection results to printed data. Print sample n Printer 9442 specifications (The optional Connection Cable 9444 and AC Adapter are required to connect the Printer 9442.) • Printing method: Thermal serial dot printer • Paper width: 112 mm • Print speed: 52.5 cps • Power supply: AC Adapter 9443 or supplied NiMH battery (prints 3000 lines after full charge using 9443) • Dimensions and weight: Approx. 160 (W) × 66.5 (H) × 170 (D) mm, 580 g n Ordering infomation For Low-Magnitude Capacitors C HiTESTER 3505 (Measurement frequencies: 1 kHz, 100 kHz and 1 MHz) C HiTESTER 3506 For High-Magnitude MLCC C HiTESTER 3504-60 (Measurement frequencies: 120 Hz and 1 kHz, four-terminal contact-checking function, constant voltage measurement at 100 mV, 500 mV and 1 V) C HiTESTER 3504-50 (Measurement frequencies: 1 kHz and 1 MHz) (Measurement frequencies: 120 Hz and 1 kHz constant voltage measurement at 500 mV and 1 V) C HiTESTER 3504-40 (Measurement frequencies: 120 Hz and 1 kHz constant voltage measurement at 500 mV and 1 V, no GP-IB interface, no Bin function) Probe and test fixtures are not supplied with the unit. Select an optional probe and test fixture when ordering. • Optional accessories FOUR-TERMINAL PROBE 9140 PINCHER PROBE 9143 TEST FIXTURE 9261 TEST FIXTURE 9262 (direct connection type) SMD TEST FIXTURE 9263 (direct connection type) SMD TEST FIXTURE 9677 (direct connection type) SMD TEST FIXTURE 9699 (direct connection type) GP-IB CONNECTION CABLE 9151-02 (2 m/ 78.74”) GP-IB CONNECTION CABLE 9151-04 (4 m/ 157.48”) PRINTER 9442 AC ADAPTER 9443 -01 (for 9442, Japan) AC ADAPTER 9443 -02 (for 9442, EU) AC ADAPTER 9443 -03 (for 9442, USA) CONNECTION CABLE 9444 (for 9442) RECORDING PAPER 1196 (for 9442 / 25 m/ 984.25”, 10 rolls) HIOKI (Shanghai) Sales & Trading Co., Ltd. : 1608-10 Shanghai Times Square Office, 93 Huai Hai Zhong Road, Shanghai, P.R.China POSTCODE: 200021 TEL +86-21-6391-0090/0092 FAX +86-21-6391-0360 E-mail: [email protected] HEAD OFFICE : 81 Koizumi, Ueda, Nagano, 386-1192, Japan TEL +81-268-28-0562 / FAX +81-268-28-0568 E-mail: [email protected] HIOKI USA CORPORATION : 6 Corporate Drive, Cranbury, NJ 08512 USA TEL +1-609-409-9109 / FAX +1-609-409-9108 E-mail: [email protected] DISTRIBUTED BY Beijing Office : A-2602 Freetown, 58 Dong San Huan Nan Road Beijing, P.R.China POSTCODE: 100022 TEL +86-10-5867-4080/4081 FAX +86-10-5867-4090 E-mail: [email protected] Guangzhou Office : Room 303, Profit Plaza, No.76, West Huangpu Road Guangzhou, P.R.China POSTCODE: 510623 TEL +86-20-38392673/2676 FAX +86-20-38392679 E-mail: [email protected] All information correct as of Jul. 1, 2008. All specifications are subject to change without notice. 3506E2-87B Printed in Japan