pdf-download 9290-10

CLAMP ON ADAPTER 9290-10 < Clamp Meters < Products
Clamp Meters(Conversion Adapter -for AC only, clamp-on
type-)
CLAMP ON ADAPTER 9290-10
OVERVIEW
Easy-to-use, current to current transformer
●
●
AC current up to 1500 A, secondary current 1/10 of primary
Ø 55 mm(2.17 in) dia. or 80 mm(3.15 in) width
Basic specifications
Measurement range
0 to 1000 A AC (50/60 Hz, continuous use), Maximum 1500 A AC (50/60 Hz, 5 minutes or
shorter)
CT ratio
10 : 1
Accuracy (at 45 to 66 Hz)
Amplitude: ±1.5 % rdg. at primary current 10 to 1500 A
Phase: ±1.0 ° max. at primary current 10 to 1500 A
Frequency characteristics
Amplitude: 40 to 1 kHz / ±1% rdg. , 20 to 4 kHz / ±2.5 % rdg.
Phase: 40 to 1 kHz / ±1.0 ° max. , 20to 4 kHz / ±3.0 ° max.
Max. circuit voltage
600 V AC rms (insulated wire)
Core jaw dia.
Ø55 mm(2.17 in) or 80 mm(3.15 in) width busbar
Secondary core dia.
27 mm(1.06 in) × 27 mm(1.06 in)
Dimensions, mass
99 mm(3.90 in)W × 194 mm(7.64 in)H × 33 mm(1.30 in)D, 500 g (17.6 oz), 3 m(9.84 ft)
cord length
Accessories
Mark band (6)
OVERVIEW