CLAMP ON SENSOR 9669
CAT III 600 V
POWER QUALITY ANALYZER
3196
OVERVIEW
Clamp-on Sensors for the POWER QUALITY ANALYZER 3196 and CLAMP ON POWER
HiTESTER 3169
For input up to AC 1000A, select our Model 9669, and up to AC 1000A, select Model 9667. Both sensors are
designed with a safety barrier to protect the user from being in direct contact with live conductors and completely
meet all CE marking requirements.
Basic specifications
Rated input current
1000 A AC
Rated output current
0.5 V AC
Accuracy (at 45 to 66 Hz)
Amplitude: ± 1.0 % rdg. ±0.01 % f.s. , Full scale (f.s.) is the 3196 range value,
Phase: ± 1° or less
Frequency characteristics
66 Hz to 5 kHz (±1 % or less from accuracy)
Max. allowable input
continuous 1000 A rms (45 to 66 Hz)
Max. circuit voltage
600 V AC rms (insulated wire)
Core jaw dia.
Ø55 mm(2.17 in), 80 mm (3.15 in) × 20 mm (0.79 in) busbar
Dimensions, mass
99.5 mm(3.92 in)W × 188 mm(7.40 in)H × 42 mm(1.65 in)D, 590 g (20.8 oz), cord length:
3 m(9.84 ft)