1602 Wall System JUNE, 2015 FEATURES Features • Slim 2" (50.8) sight lines • Tubular construction with shear block connections • Split mullion unitized system for horizontal strip window • Thermally improved framing • Range of mullion sizes to suit design parameters • Standard infill options 1/4" (6.4) and 1" (25.4), other infills available • Integrated entrance framing • Two color option • PermanodicTM anodized finishes in seven choices • Painted finishes in standard and custom choices Optional Features • Deep covers available • Deep and heavy-weight mullions © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-075 For specific product applications, Consult your Kawneer representative. kawneer.com ADMD090 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1602 Wall System BLANK PAGE ADMD090 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 JUNE, 2015 EC 97911-075 1602 Wall System JUNE, 2015 EC 97911-075 3 INDEX PICTORIAL VIEW................................................................................ 4 ELEVATION DETAILS WITHOUT BACKPAN...................................... 5 ELEVATION DETAILS WITH BACKPAN............................................. 6 ENTRANCE DETAILS......................................................................... 7 CORNER DETAILS.............................................................................. 8 1602 WALL ELEVATION AND DETAILS............................................. 9 COMPONENTS ................................................................................. 10 WIND LOAD/DEADLOAD CHARTS............................................. 11-17 THERMAL CHARTS..................................................................... 18-21 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Architects - Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD090 Tubular mullions are horizontals with shear block construction. Rain screen pressure equalized system. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1602 Wall System PICTORIAL VIEW ADMD090 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 JUNE, 2015 EC 97911-075 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com 1 5 9 10 3 10 8 ELEVATION IS NUMBER KEYED TO DETAILS 12 2" (50.8) Door opening width 11 12A HEAVY WALL ADMD090 2" (50.8) EC 97911-075 12 12A 7 Door opening height 14 7-5/16" (185.7) 9 6-1/16" (154) Overall frame height Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 1602 Wall System ELEVATION AND DETAILS (WITHOUT BACK PAN) SCALE 3" = 1'-0" 2 11 13 6 1 4 13 2 3 6-1/16" (154) 7-5/16" (185.7) 4 5 6 14 7 8 5 4 6 1 3 5 ELEVATION IS NUMBER KEYED TO DETAILS 7 8 8A 2" (50.8) ADMD090 2 6-1/16" (154) 7-5/16" (185.7) 3 5 HEAVY WALL kawneer.com © Kawneer Company, Inc., 2011 ELEVATION AND DETAILS (WITH BACK PAN) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1602 Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 2" (50.8) 7 7-5/16" (185.7) 6 6-1/16" (154) 6 JUNE, 2015 EC 97911-075 SCALE 3" = 1'-0" 1 8 8A 4 1-15/16" (88.9) TYP © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 kawneer.com 1602 Wall System EC 97911-075 ENTRANCE DETAILS SCALE 3" = 1'-0" 1 3 2 4 B/H OR O/P 2 C/H ELEVATION IS NUMBER KEYED TO DETAILS BUTT HUNG OR OFFSET PIVOT DOOR JAMB 1 TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER DOOR JAMB CENTER HUNG 4 3 TRANSOM BAR CENTER HUNG CONCEALED OVERHEAD OR FLOOR CLOSER ADMD090 7 VISION 2" (50.8) 90° OUTSIDE CORNER 90° INSIDE CORNER AN SP R D SPANDREL N O SI VI EL VISION 135° OUTSIDE CORNER 135° INSIDE CORNER ADMD090 kawneer.com © Kawneer Company, Inc., 2011 CORNER DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1602 Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SPANDREL SPANDREL 6-1/8" (155.6) VISION 8 JUNE, 2015 EC 97911-075 SCALE 3" = 1'-0" 2" (50.8) © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. kawneer.com 3 4 2 5 1 2 Overall frame height EC 97911-075 TYPE A TYPE B HORIZONTAL STRIP WINDOW PUNCHED OPENING WINDOW Overall frame width ELEVATION IS NUMBER KEYED TO DETAILS 3 5 ADMD090 1 1 2 2" (50.8) 2" (50.8) 3 4 4-15/16" (125.4) 4 NOTE: 1602 WINDOW CAN ALSO BE FABRICATED AS A STICK SYSTEM. 4-15/16" (125.4) 1 4-15/16" (125.4) Overall frame height Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 1602 Wall System 1602 WINDOW ELEVATION AND DETAILS SCALE 3" = 1'-0" Overall frame width 3 2 4 ELEVATION IS NUMBER KEYED TO DETAILS 9 ADMD090 5-1/4" (133.4) 2" (50.8) 2" (50.8) OPTIONAL COVERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 5-5/16" (134.9) 4" (101.6) 7-5/16" (185.7) 3/4" (19.1) 1" (25.4) 1-1/4" (31.8) COMPONENTS WITHOUT BACKPAN ADAPTORS kawneer.com © Kawneer Company, Inc., 2011 2-7/8" (73.0) 1602 Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2" (50.8) 4-15/16" (125.4) 10 JUNE, 2015 EC 97911-075 SCALE 3" = 1'-0" WALL MULLIONS (VERTICAL AND HORIZONTAL) 1602 Wall System JUNE, 2015 EC 97911-075 11 WIND LOAD/DEADLOAD CHARTS Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. Wind load charts contained herein are based upon nominal wind load utilized in allowable stress design. To convert ultimate wind loads to nominal loads, multiply ultimate wind loads by a factor of 0.6 per ASCE/SEI 7. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. DEADLOAD CHARTS Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.4) thick glass supported on two setting blocks placed at the loading points shown. © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS kawneer.com ADMD090 1602 Wall System JUNE, 2015 EC 97911-075 WIND LOAD CHARTS SINGLE SPAN TWIN SPAN METERS METERS 1.0 2.0 17 29 4.0 12 11 10 3.0 9 A 8 B C 2.0 D E 7 6 5 METERS GLASS HEIGHT IN FEET 13 28 27 25 24 23 7.0 22 21 20 6.0 A 19 18 17 5.0 16 4 1.0 3 1 14 1 2 I = 3.883(161.62 x 10 ) S = 1.488(24.38 x 103) 3 4 5 6 7 8 SPAN IN FEET C 4.0 13 4 0 B 15 820301 2 0 8.0 26 12 0 1 1.0 29 15 14 4.0 11 A 10 3.0 9 7 B C D 6 E 8 METERS GLASS HEIGHT IN FEET 12 2.0 23 1 5 6 7 8 7.0 A 22 21 20 6.0 19 B 18 5.0 C 15 820302 2 8.0 24 16 1.0 9.0 25 17 3 2.0 26 4 4 8 27 5 3 7 28 GLASS HEIGHT IN FEET MULLION HEIGHT 16 13 MULLION HEIGHT EQUAL EQUAL 17 2 6 METERS 2.0 30 1 5 TWIN SPAN 18 0 4 SPAN IN FEET METERS 1.0 0 3 E A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN 2 D I = 5.507(229.22 x 104) S = 2.105(34.49 x 103) SPAN IN FEET D 14 4.0 13 12 E 0 1 2 3 4 5 6 7 8 SPAN IN FEET ADMD090 kawneer.com © Kawneer Company, Inc., 2011 14 9.0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 15 GLASS HEIGHT IN FEET MULLION HEIGHT 16 2.0 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 30 MULLION HEIGHT EQUAL EQUAL 18 METERS 1.0 METERS 12 1602 Wall System JUNE, 2015 EC 97911-075 WIND LOAD CHARTS SINGLE SPAN TWIN SPAN METERS METERS 2.0 1.0 30 17 29 4.0 12 10 3.0 9 8 A 7 B 6 C D E METERS 11 2.0 5 27 8.0 26 25 24 23 7.0 22 21 20 6.0 19 18 A 17 4 5.0 16 1.0 3 15 820303 2 1 1 2 3 4 5 6 7 8 4.0 13 12 C 0 1 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN 2 1.0 29 15 14 4.0 A 11 10 3.0 B C D E 9 8 7 METERS GLASS HEIGHT IN FEET © Kawneer Company, Inc., 2011 12 2.0 6 1.0 3 820316 2 1 I = 7.570(315.09 x 10 ) S = 2.339(38.33 x 103) 4 6 7 8 SPAN IN FEET kawneer.com 2.0 9.0 8.0 A 24 23 7.0 22 21 20 6.0 B 19 18 16 5 8 25 17 4 D 26 4 3 7 27 5 2 E 28 GLASS HEIGHT IN FEET MULLION HEIGHT 16 13 MULLION HEIGHT EQUAL EQUAL 17 1 6 METERS 2.0 30 0 5 TWIN SPAN 18 0 4 SPAN IN FEET METERS 1.0 3 C 5.0 15 D 14 E 4.0 13 12 0 1 2 3 4 5 SPAN IN FEET ADMD090 6 7 8 METERS 0 B 14 I = 2.808(116.88 x 104) S = 1.233(20.21 x 103) SPAN IN FEET Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 9.0 METERS 14 2.0 28 GLASS HEIGHT IN FEET MULLION HEIGHT 15 13 MULLION HEIGHT EQUAL EQUAL 18 16 GLASS HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1.0 0 13 1602 Wall System JUNE, 2015 EC 97911-075 WIND LOAD CHARTS SINGLE SPAN SINGLE SPAN METERS METERS 16 15 14 4.0 16 15 14 GLASS HEIGHT IN FEET 3.0 9 8 METERS 11 A 7 2.0 B C D E 6 5 4 3 4 5 6 7 A 7 2.0 B C D E 6 1.0 I = 1.970(82.00 x 104) S = 0.982(16.09 x 103) 8 821852 1 0 0 SPAN IN FEET 1 2 3 4 5 6 7 8 I = 2.131(88.70 x 104) S = 1.014(16.61 x 103) SPAN IN FEET SINGLE SPAN METERS 2.0 MULLION HEIGHT 1.0 18 17 16 15 14 4.0 13 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) 12 11 10 3.0 9 8 A 7 2.0 B C D E 6 5 4 1.0 3 820853 & 821854 2 1 0 METERS 2 8 2 820317 1 3.0 9 3 1 0 10 4 2 0 11 5 1.0 3 12 0 1 2 3 4 5 6 7 8 I = 1.916(79.75 x 104) S = 0.830(13.60 x 103) SPAN IN FEET ADMD090 kawneer.com © Kawneer Company, Inc., 2011 10 4.0 13 12 GLASS HEIGHT IN FEET GLASS HEIGHT IN FEET 13 17 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 17 2.0 18 METERS 18 MULLION HEIGHT 1.0 2.0 MULLION HEIGHT 1.0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 1602 Wall System JUNE, 2015 EC 97911-075 15 DEADLOAD CHARTS A - 1/8 POINT LOADING B - 1/4 POINT LOADING 1/4" INFILL 1" INFILL METERS METERS 2.0 1.0 16 16 15 15 14 11 3.0 9 8 7 2.0 6 A 5 4 820301 1 7 2.0 6 5 0 1 2 3 4 5 6 7 1.0 B 1 I = 0.766(31.88 x 104) S = 0.766(12.55 x 103) 8 A 2 0 0 1 2 3 4 5 6 SPAN IN FEET SPAN IN FEET 1/4" INFILL 1" INFILL METERS METERS 1.0 2.0 16 16 15 15 7 8 2.0 14 14 4.0 12 11 11 GLASS HEIGHT IN FEET 12 10 3.0 METERS 9 8 7 2.0 A 6 4.0 13 5 10 3.0 9 METERS 13 GLASS HEIGHT IN FEET 8 3 B 2 8 7 2.0 6 5 4 4 1.0 3 B 2 1 0 3.0 9 4 1.0 3 0 1 2 3 4 5 6 7 8 1.0 A 3 820302 I = 0.890(37.04 x 104) S = 0.890(14.58 x 103) 2 B 1 0 0 1 2 3 4 5 SPAN IN FEET SPAN IN FEET kawneer.com 10 METERS GLASS HEIGHT IN FEET 11 METERS GLASS HEIGHT IN FEET 12 10 4.0 13 12 0 2.0 14 4.0 13 1.0 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1.0 ADMD090 6 7 8 GLASS HEIGHT IN FEET DEADLOAD CHARTS 14 12 0 0 4.0 11 3.0 8 7 6 2.0 5 A 4 3 B 1.0 2 1 0 0 1 1 2 2 3 3 4 4 5 5 6 1.0 6 7 13 10 9 8 7 A 4 3 2 1 7 8 820303 8 I = 0.763(31.76 x 104) S = 0.763(12.50 x 103) SPAN IN FEET 1/4" INFILL 1" INFILL METERS 2.0 METERS 16 16 1.0 15 14 15 4.0 12 12 11 11 3.0 6 2.0 5 B 1.0 820316 4 I = 1.064(44.29 x 10 ) S = 1.064(17.44 x 103) SPAN IN FEET ADMD090 0 0 1 2 3 2.0 14 13 4.0 10 9 3.0 8 7 6 2.0 5 4 3 A 1.0 2 1 B SPAN IN FEET 4 5 6 7 8 kawneer.com © Kawneer Company, Inc., 2011 15 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1602 Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 10 METERS 13 GLASS HEIGHT IN FEET 9 METERS 1.0 METERS GLASS HEIGHT IN FEET 16 JUNE, 2015 EC 97911-075 A - 1/8 POINT LOADING B - 1/4 POINT LOADING 1/4" INFILL METERS 16 2.0 1602 Wall System JUNE, 2015 EC 97911-075 17 DEADLOAD CHARTS A - 1/8 POINT LOADING B - 1/4 POINT LOADING 1/4" INFILL 1" INFILL METERS METERS 2.0 1.0 16 16 15 15 14 3.0 9 8 7 2.0 6 5 A 4 820317 1 0 1 2 3 4 5 6 7 I = 0.583(24.27 x 104) S = 0.583(9.55 x 103) 5 1.0 8 2 A 1 B 0 1 2 3 4 5 6 SPAN IN FEET 1/4" INFILL 1" INFILL METERS METERS 1.0 2.0 16 16 15 15 7 8 2.0 14 4.0 11 3.0 METERS 9 8 7 2.0 6 A 5 10 3.0 9 METERS GLASS HEIGHT IN FEET 12 11 10 4.0 13 12 8 7 2.0 6 5 4 4 1.0 3 B 2 1 0 2.0 6 SPAN IN FEET 13 GLASS HEIGHT IN FEET 7 0 14 821852 1 2 3 4 5 6 7 8 A 2 I = 0.732(30.47 x 10 ) S = 0.732(12.00 x 103) 4 0 1.0 3 B 1 0 0 1 2 3 4 5 SPAN IN FEET SPAN IN FEET kawneer.com 8 3 B 2 3.0 9 4 1.0 3 10 METERS GLASS HEIGHT IN FEET 11 METERS GLASS HEIGHT IN FEET 12 11 10 4.0 13 12 0 2.0 14 4.0 13 1.0 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1.0 ADMD090 6 7 8 1602 Wall System JUNE, 2015 EC 97911-075 THERMAL CHARTS Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) (Based on single bay of Curtain Wall/Window Wall) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 15'-8" Frame Width 5'-0" 2'-0" 9'-6" Frame Height D.L.O. 7'-0" D.L.O. D.L.O. Example Glass U-Factor = 0.42 Btu/hr • ft2 • °F Total Daylight Opening = 3(5' x 7') + 3(5' x 2') = 135 ft2 Total Projected Area = 15'-8" x 9'-6" = 148.83 ft2 Percent of Glass = (Total Daylight Opening ÷ Total Projected Area)100 = (135 ÷ 148.83)100 = 91% System U-Factor vs Percent of Glass Area 0.80 0.70 E n PL ig M es A rD EX Fo 0.60 ot (N 0.65 0.55 0.50 0.49 0.45 0.40 0.35 0.30 ) COG U-Factor 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.25 70 75 80 85 90 91% 0.20 Vision Area / Total Area % Based on 91% glass and center of glass U-Factor of 0.42 System U-Factor is equal to 0.49 Btu/hr • ft2 • °F ADMD090 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.75 95 18 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. COG U-Factor kawneer.com System U-Factor (Btu/hr • ft2 • °F) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. JUNE, 2015 1602 Wall System EC 97911-075 Vision Area / Total Area % Notes for System U-Factor, SHGC and VT charts: For glass values that are not listed, linear interpolation is permitted. Glass properties are based on center of glass values and are obtained from your glass supplier. ADMD090 19 THERMAL CHARTS Note: Values in parentheses are metric. COG = Center of Glass. Charts are generated per AMMA 507 System U-Factor vs Percent of Glass Area Vision Area / Total Area % (Total Daylight Opening / Projected Area) COG VT Vision Area / Total Area % (Total Daylight Opening / Projected Area) ADMD090 kawneer.com © Kawneer Company, Inc., 2011 THERMAL CHARTS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. System SHGC 1602 Wall System Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. System VT 20 JUNE, 2015 EC 97911-075 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area COG SHGC Charts are generated per AAMA 507 Visible Transmittance (VT) vs Percent of Vision Area 1602 Wall System JUNE, 2015 EC 97911-075 THERMAL PERFORMANCE MATRIX (NFRC SIZE) 1" GLAZING WITH ALUMINUM PRESSURE PLATE Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.61 0.46 0.59 0.44 0.58 0.42 0.56 0.40 0.54 0.38 0.53 0.36 0.51 0.34 0.49 0.32 0.48 0.30 0.46 0.28 0.44 0.26 0.43 0.24 0.41 0.22 0.39 0.20 0.38 NOTE:For glass values that are not listed, linear interpolation is permitted. 1.U-Factors are determined in accordance with NFRC 100. 2.SHGC and VT values are determined in accordance with NFRC 200. 3.Glass properties are based on center of glass values and are obtained from your glass supplier. 4.Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). SHGC Matrix 2 © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 kawneer.com 21 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.70 0.75 0.69 0.70 0.65 0.70 0.64 0.65 0.61 0.65 0.60 0.60 0.56 0.60 0.55 0.55 0.51 0.55 0.51 0.50 0.47 0.50 0.46 0.45 0.42 0.45 0.41 0.40 0.38 0.40 0.37 0.35 0.33 0.35 0.32 0.30 0.28 0.30 0.28 0.25 0.24 0.25 0.23 0.20 0.19 0.20 0.18 0.15 0.15 0.15 0.14 0.10 0.10 0.10 0.09 0.05 0.05 0.05 0.05 ADMD090 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1602 Wall System BLANK PAGE ADMD090 kawneer.com © Kawneer Company, Inc., 2011 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 22 JUNE, 2015 EC 97911-075