2250 IG DECEMBER, 2013 FEATURES Features • • • • • • Economical High performance Ribbon Window/Curtain Wall system Narrow 2-1/4" sight line 4-1/2", 6" and 7-1/2" system depths for 1" infill 5-1/4" and 6-3/4 system depths for 1/4" infill Inside glazed • • • • Incidental water management capability Integral perimeter caulk leg Thermally improved Snap-on covers • Two color option • PermanodicTM anodized finishes in seven choices • • • • Painted finishes in standard and custom choices Type “A” fabrication: Screw Splice or Shear Block Type “B” fabrication: Punched openings SSG Option Optional Features • • • • • © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-053 Steel reinforcing available Rain screen and backpans Pressure plate option for outside glazing requirements Integrates with concealed GLASSventTM for curtain wall Profit$Maker™ plus die sets available. Product Applications • Ideal for low to high-rise applications For specific product applications, Consult your Kawneer representative. kawneer.com ADMD150 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG BLANK PAGE ADMD150 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 DECEMBER, 2013 EC 97911-053 2250 IG DECEMBER, 2013 EC 97911-053 3 INDEX PICTORIAL VIEW............................................................................. 5-7 DETAILS - 1" INFILL...................................................................... 8-10 ENTRANCE DETAILS - 1" INFILL.................................................... 11 CORNERS - 1" INFILL...................................................................... 12 GLASSventTM FOR CURTAIN WALL - 1" INFILL............................. 13 MISCELLANEOUS DETAILS - 1" INFILL ........................................ 14 DETAILS - 1/4" INFILL................................................................. 15-17 ENTRANCE DETAILS - 1/4" INFILL................................................. 18 CORNERS - 1/4" INFILL................................................................... 19 GLASSventTM FOR CURTAIN WALL - 1/4" INFILL.......................... 20 MISCELLANEOUS DETAILS - 1/4" INFILL ..................................... 21 WIND LOAD CHARTS.................................................................. 22-33 DEADLOAD CHARTS.................................................................. 34-37 THERMAL CHARTS .................................................................... 38-45 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI ) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer.com ADMD150 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG BLANK PAGE ADMD150 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 4 DECEMBER, 2013 EC 97911-053 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 2250 IG EC 97911-053 PICTORIAL VIEW TYPE “A” ASSEMBLY Screw Spline for Ribbon Windows VERTICAL MULLION HEAD THERMAL ISOLATOR COVER ADMD150 GLASS STOP HORIZONTAL GLASS STOP SILL 5 HEAD THERMAL ISOLATOR GLASS STOP SILL COVER ADMD150 kawneer.com © Kawneer Company, Inc., 2013 PICTORIAL VIEW Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 6 DECEMBER, 2013 EC 97911-053 TYPE “B” ASSEMBLY Screw Spline for Ribbon Windows GLASS STOP HORIZONTAL © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 2250 IG EC 97911-053 PICTORIAL VIEW SHEAR BLOCK ASSEMBLY Shear Block for Curtain Wall VERTICAL MULLION SHEAR BLOCK HEAD THERMAL ISOLATOR COVER ADMD150 GLASS STOP HORIZONTAL GLASS STOP FLAT FILLER SILL 7 4A 1A 4 5 4A 5A 4 6 3A 5A 6A 1 1A 2 2A ELEVATION IS NUMBER KEYED TO DETAILS 3 3A 4A 6" (152.4) 6" (152.4) 1 1A 2 2A 3 3A 2-1/4" (57.2) 2-1/4" (57.2) 5 5A ADMD150 6 6A kawneer.com © Kawneer Company, Inc., 2013 RIBBON WINDOW (TYPE "A" SCREW SPLINE - 1" INFILL) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 3 5 6" (152.4) 4 2-1/4" (57.2) SCALE 3" = 1'-0" 6" (152.4) 6" (152.4) 2-1/4" (57.2) 8 DECEMBER, 2013 EC 97911-053 NOTE: Available in 4-1/2", 6" (Shown) and 7-1/2" depths. Consult you Kawneer Representative for more information. 1 4 4A 1A 4 5 4A 5A 4 kawneer.com 2-1/4" (57.2) 3 5 6 5A 6A 4A 2-1/4" (57.2) SCALE 3" = 1'-0" ELEVATION IS NUMBER KEYED TO DETAILS 2-1/4" (57.2) 2-1/4" (57.2) 5 5A ADMD150 6" (152.4) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-053 6" (152.4) 6" (152.4) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. DECEMBER, 2013 2250 IG 1 1A 2 2A 3 3A 6" (152.4) 6" (152.4) 1 1A 2 2A 3 3A 6 9 RIBBON WINDOW (TYPE "B" SCREW SPLINE - 1" INFILL) NOTE: Available in 4-1/2", 6" (Shown) and 7-1/2" depths. Consult you Kawneer Representative for more information. 1 3A 6A 6A 6 8 3 7A 8A 4 3 2 2A 5 5A NOTE: Available in 4-1/2", 6" (Shown) and 7-1/2" depths. Consult you Kawneer Representative for more information. 6A 6" (152.4) 6" (152.4) 1 1A 4 2 2A ELEVATION IS NUMBER KEYED TO DETAILS 3 4 5 ADMD150 5A 2-1/4" (57.2) 2-1/4" (57.2) 7 7A 8 8A kawneer.com © Kawneer Company, Inc., 2013 CURTAIN WALL (SHEAR BLOCK - 1" INFILL) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 2-1/4" (57.2) 2250 IG Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7 6" (152.4) 6 6" (152.4) 6" (152.4) 2-1/4" (57.2) 10 DECEMBER, 2013 EC 97911-053 SCALE 3" = 1'-0" 1A 2250 IG DECEMBER, 2013 EC 97911-053 11 ENTRANCE DETAILS (1" INFILL) SCALE 3" = 1'-0" 2 1 1A 1B Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 3 TRANSOM BAR 4 B/H OR O/P BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER C/H ELEVATION IS NUMBER KEYED TO DETAILS 1A TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING CONCEALED OVERHEAD CLOSER 3 1B DOOR JAMB 1-7/8" (47.6) BUTT HUNG OR OFFSET PIVOT © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 7/8" (22.2) TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH LCN CONCEALED OVERHEAD CLOSER OR SURFACE CLOSER 2 TRANSOM BAR 4 CENTER HUNG CONCEALED OVERHEAD OR FLOOR CLOSER DOOR JAMB CENTER HUNG kawneer.com ADMD150 90° OUTSIDE CORNER SCREW SPLINE 90° OUTSIDE CORNER SHEAR BLOCK 90° INSIDE CORNER SCREW SPLINE 90° INSIDE CORNER SHEAR BLOCK ADMD150 kawneer.com © Kawneer Company, Inc., 2013 CORNERS (1" INFILL) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 12 DECEMBER, 2013 EC 97911-053 SCALE 3" = 1'-0" 2250 IG DECEMBER, 2013 EC 97911-053 GLASSventTM FOR CURTAIN WALL (1" INFILL) SCALE 3" = 1'-0" 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. HEAD 1 3 2 ELEVATION IS NUMBER KEYED TO DETAILS 2 SILL JAMB AT SSG MULLION 3 JAMB LOCKING HARDWARE HINGE AND SUPPORT HARDWARE DESCRIPTION OUTSWING CASEMENT/PROJECT OUT CAM HANDLES STANDARD A.C./CUSTODIAL/SPANNER LOCK (REMOVABLE KEY HANDLES) OPTIONAL 4 BAR HINGES STANDARD SCREWS STANDARD © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. HARDWARE SELECTION GUIDE CAM HANDLES kawneer.com SPANNER LOCK 4 BAR HINGE ADMD150 SCREEN WITH STANDARD WICKET SCREEN WITH FULL WICKET 13 MISCELLANEOUS (1" INFILL) PRESSURE PLATE HORIZONTAL FOR OUTSIDE GLAZING STEEL REINFORCING OPTIONAL STEEL REINFORCING AS REQUIRED ADMD150 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 14 DECEMBER, 2013 EC 97911-053 SCALE 3" = 1'-0" 2-1/4" (57.2) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-053 4 4A 3 4 4 kawneer.com 1 5 4A 4 5 6 5 6 ELEVATION IS NUMBER KEYED TO DETAILS 4A 5 ADMD150 5-1/4" (133.4) 5-1/4" (133.4) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. DECEMBER, 2013 2250 IG 2-1/4" (57.2) 6 15 RIBBON WINDOW (TYPE "A" SCREW SPLINE - 1/4" INFILL) SCALE 3" = 1'-0" NOTE: Available in 5-1/4" (Shown) and 6-3/4" depths. Consult you Kawneer Representative for more information. 1 4A 3 5-1/4" (133.4) 1 1 2 3 2 3 4 1 4 4 4A 4 1 5 5 6 4A 3 5 6 5-1/4" (133.4) 1 1 2 3 ELEVATION IS NUMBER KEYED TO DETAILS 3 2-1/4" (57.2) 4A 5 ADMD150 6 kawneer.com © Kawneer Company, Inc., 2013 4A 3 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. RIBBON WINDOW (TYPE "B" SCREW SPLINE - 1/4" INFILL) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2250 IG 5-1/4" (133.4) 5-1/4" (133.4) 2-1/4" (57.2) 16 DECEMBER, 2013 EC 97911-053 SCALE 3" = 1'-0" NOTE: Available in 5-1/4" (Shown) and 6-3/4" depths. Consult you Kawneer Representative for more information. MAX. UNIT WIDTH 24’-0” 2 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. kawneer.com 4 5 6 4 5 6 4 2-1/4" (57.2) EC 97911-053 ELEVATION IS NUMBER KEYED TO DETAILS 5 ADMD150 5-1/4" (133.4) 5-1/4" (133.4) © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. DECEMBER, 2013 2250 IG 1 2 2 5-1/4" (133.4) 1 2 3 2 3 2-1/4" (57.2) 6 17 CURTAIN WALL (SHEAR BLOCK - 1/4" INFILL) SCALE 3" = 1'-0" NOTE: Available in 5-1/4" (Shown) and 6-3/4" depths. Consult you Kawneer Representative for more information. 2250 IG 18 DECEMBER, 2013 ENTRANCE DETAILS ( 1/4" INFILL) EC 97911-053 3 TRANSOM BAR 4 BUTT HUNG OR OFFSET PIVOT WITH SURFACE CLOSER OR FLOOR CLOSER B/H OR O/P C/H ELEVATION IS NUMBER KEYED TO DETAILS 1A TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH SINGLE ACTING OFFSET ARM CLOSER 7/8" (22.2) 3 1-7/8" (47.6) DOOR JAMB BUTT HUNG OR OFFSET PIVOT 1B TRANSOM BAR BUTT HUNG OR OFFSET PIVOT WITH LCN CONCEALED OVERHEAD CLOSER OR SURFACE CLOSER 2 4 TRANSOM BAR DOOR JAMB CENTER HUNG CONCEALED OVERHEAD OR FLOOR CLOSER CENTER HUNG ADMD150 kawneer.com © Kawneer Company, Inc., 2013 1 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2 1 1A 1B Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SCALE 3" = 1'-0" © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 2250 IG EC 97911-053 CORNERS ( 1/4" INFILL) SCALE 3" = 1'-0" 90° OUTSIDE CORNER SCREW SPLINE 90° OUTSIDE CORNER SHEAR BLOCK 90° INSIDE CORNER SCREW SPLINE 90° INSIDE CORNER SHEAR BLOCK ADMD150 19 20 2250 IG GLASSvent DECEMBER, 2013 TM FOR CURTAIN WALL (1/4" INFILL) EC 97911-053 SCALE 3" = 1'-0" Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 1 HEAD 1 3 2 ELEVATION IS NUMBER KEYED TO DETAILS 2 SILL JAMB AT SSG MULLION 3 JAMB HINGE AND SUPPORT HARDWARE CAM HANDLES SPANNER LOCK OUTSWING CASEMENT/PROJECT OUT CAM HANDLES STANDARD A.C./CUSTODIAL/SPANNER LOCK (REMOVABLE KEY HANDLES) OPTIONAL 4 BAR HINGES STANDARD SCREWS STANDARD 4 BAR HINGE ADMD150 SCREEN WITH STANDARD WICKET SCREEN WITH FULL WICKET kawneer.com © Kawneer Company, Inc., 2013 LOCKING HARDWARE DESCRIPTION Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. HARDWARE SELECTION GUIDE © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. DECEMBER, 2013 kawneer.com 2250 IG EC 97911-053 MISCELLANEOUS (1/4" INFILL) SCALE 3" = 1'-0" PRESSURE PLATE HORIZONTAL FOR OUTSIDE GLAZING STEEL REINFORCING OPTIONAL STEEL REINFORCING AS REQUIRED ADMD150 21 22 2250 IG DECEMBER, 2013 WIND LOAD / DEADLOAD CHARTS EC 97911-053 DEADLOAD CHARTS Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Horizontal or deadload limitations are based upon 1/8" (3.2), maximum allowable deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1" (25.4) thick insulating glass or 1/4" (6.35) thick glass supported on two setting blocks placed at the loading points shown. ADMD150 kawneer.com © Kawneer Company, Inc., 2013 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS 2250 IG DECEMBER, 2013 EC 97911-053 23 WIND LOAD CHARTS (1" INFILL) (TYPE "A" SCREW SPLINE) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN 16 15 .5 1 1.5 METERS 2 B 1 C 4 D E 4.5 13 4 10 7 2 6 5 1.5 4-1/2" (114.3) 2.5 8 METERS 3 9 4 3.5 11 A 10 3 B 9 C D E 8 7 2.5 METERS 3.5 11 MULLION HEIGHT IN FEET 12 2-1/4" (57.2) 12 MULLION HEIGHT 13 2 6 5 1.5 4 1 3 165119 & 165029 165124 & 165029 I = 3.014(125.4 x 104) S = 1.315(21.6 x 103) I = 0.769(32.0 x 104) S = 0.672(11.0 x 103) .5 1 2 .5 1 2 3 4 5 6 7 0 8 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN SINGLE SPAN METERS .5 16 1 METERS 1.5 2 4 A 2.5 7 2 6 5 6" (152.4) 8 METERS 3 D E 9 MULLION HEIGHT IN FEET C 3-3/4" (95.3) 3.5 B 1 1.5 2 1.5 4 4.5 14 B 13 C 4 D E 3.5 12 MULLION HEIGHT 12 11 .5 15 4.5 14 13 A 16 15 10 8 11 10 3 9 2.5 8 7 2 6 5 1.5 4 1 3 2 .5 1 1 3 165110 & 165016 165125 & 165016 I = 6.885(286.5 x 104) S = 2.161(35.4 x 103) I = 2.810(117.0 x 104) S = 1.455(23.8 x 103) 0 2 .5 1 0 0 1 2 3 4 5 6 7 8 0 MULLION CENTERS IN FEET kawneer.com 1 2 3 4 5 6 7 MULLION CENTERS IN FEET ADMD150 8 METERS 1 1 3 2 MULLION HEIGHT IN FEET 2 14 0 © Kawneer Company, Inc., 2013 1.5 15 4.5 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. .5 16 14 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS A SINGLE SPAN 1 2 3 15 14 12 C 11 D 10 4 5 6 7 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) 2 16 A 4.5 B 13 4 3.5 E 3 9 8 2.5 7 6 2 5 1.5 4 3 2 1 1 .5 165132 & 166010 165134 & 166010 I = 13.354(555.8 x 104) S = 3.291(53.9 x 103) I = 6.800(283.0 x 104) S = 2.499(41.0 x 103) 0 8 MULLION CENTERS IN FEET ADMD150 .5 METERS 0 1 1 8 2 3 1.5 E D 4 5 2 15 14 4.5 13 12 A 4 11 10 B 3.5 9 3 C 6 2.5 7 6 2 5 4 1.5 3 2 1 1 .5 7 kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS (1" INFILL) METERS 1.5 MULLION HEIGHT IN FEET 2250 IG © Kawneer Company, Inc., 2013 0 1 5-1/4" (133.4) METERS MULLION HEIGHT .5 7-1/2" (190.5) 16 METERS SINGLE SPAN Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION HEIGHT IN FEET 24 DECEMBER, 2013 EC 97911-053 (TYPE "A" SCREW SPLINE) SINGLE SPAN 0 MULLION CENTERS IN FEET 8 2250 IG DECEMBER, 2013 EC 97911-053 25 WIND LOAD CHARTS (1" INFILL) (TYPE "B" SCREW SPLINE) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) METERS A 15 B 14 C 13 D E .5 1 1.5 SINGLE SPAN METERS 2 4 4.5 4 7 2 6 5 1.5 4-1/2" (114.3) 2.5 8 METERS 3 9 2-1/4" (57.2) MULLION HEIGHT 10 MULLION HEIGHT IN FEET 12 4 3.5 11 A 10 3 B 9 C D E 8 7 2.5 2 6 5 1.5 4 1 3 .5 1 165112 165123 I = 3.500(145.7 x 104) S = 1.582(25.9 x 103) I = 0.749(31.2 x 104) S = 0.649(10.6 x 103) 2 .5 1 2 3 4 5 6 7 0 8 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN SINGLE SPAN METERS METERS .5 16 1 1.5 2 13 4 B E 8 2.5 7 2 6 5 6" (152.4) 3 D 9 METERS C MULLION HEIGHT IN FEET 3.5 3-3/4" (95.3) MULLION HEIGHT A 11 1 1.5 2 A 15 4.5 14 12 .5 16 15 10 8 1.5 4.5 14 B 13 C 12 D E 11 4 3.5 10 3 9 2.5 8 7 2 6 5 1.5 4 4 1 3 2 .5 1 1 3 165099 165107 I = 7.350(305.9 x 104) S = 2.540(41.6 x 103) I = 2.624(109.2 x 104) S = 1.378(22.6 x 103) 2 .5 1 0 0 0 1 2 3 4 5 6 7 0 8 kawneer.com 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET ADMD150 8 METERS 1 1 3 2 MULLION HEIGHT IN FEET 2 13 3.5 11 0 © Kawneer Company, Inc., 2013 1.5 14 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 15 4.5 12 .5 16 METERS 16 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN 1 2 3 15 14 13 12 11 10 4 5 6 7 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) 2 A 16 B 4.5 C D 4 3.5 E 3 9 8 2.5 7 6 2 5 1.5 4 3 2 1 1 .5 165138 165077 I = 15.061(626.9 x 104) S = 4.129(67.7 x 103) I = 6.949(289.2 x 104) S = 2.612(42.8 x 103) 0 8 MULLION CENTERS IN FEET ADMD150 .5 METERS 0 1 1 9 2 3 1.5 10 D 4 5 2 15 14 4.5 13 12 A 4 11 C B 3.5 E 3 8 2.5 7 6 2 5 4 1.5 3 2 1 1 .5 6 7 kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS (1" INFILL) METERS 1.5 MULLION HEIGHT IN FEET METERS 5-1/4" (133.4) 2250 IG © Kawneer Company, Inc., 2013 0 1 MULLION HEIGHT .5 7-1/2" (190.5) 16 METERS SINGLE SPAN Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION HEIGHT IN FEET 26 DECEMBER, 2013 EC 97911-053 (TYPE "B" SCREW SPLINE) SINGLE SPAN 0 MULLION CENTERS IN FEET 8 2250 IG DECEMBER, 2013 EC 97911-053 27 WIND LOAD CHARTS (1" INFILL) (SHEAR BLOCK) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) SINGLE SPAN .5 1 1.5 D E 12 4.5 13 4 4 12 10 MULLION HEIGHT 3.5 11 7 2 6 5 1.5 4-1/2" (114.3) 2.5 8 METERS 3 9 3.5 11 A 10 3 B 9 C D E 8 7 2.5 2 6 5 1.5 4 4 1 3 1 3 2 .5 1 165128 165048 I = 3.328(138.5 x 104) S = 1.572(25.8 x 103) I = 0.770(32.1 x 104) S = 0.682(11.2 x 103) 2 .5 1 0 1 2 3 4 5 6 7 0 8 1 2 4 5 6 7 MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN 1 8 METERS METERS .5 16 1.5 2 .5 30 15 1.5 1 2 9 29 4.5 14 A 28 13 A 8 2.5 E 7 2 6 5 1.5 MULLION HEIGHT IN FEET D MULLION HEIGHT EQUAL EQUAL 9 METERS 3 6" (152.4) C MULLION HEIGHT B 10 8 26 3.5 11 8.5 27 4 12 MULLION HEIGHT IN FEET 3 MULLION CENTERS IN FEET 25 7.5 24 B 23 22 C 21 1 3 D 19 .5 1 6 E 5.5 17 165127 2 6.5 20 18 4 7 I = 7.223(300.6 x 104) S = 2.442(40.0 x 103) 0 5 16 15 4.5 14 0 1 2 3 4 5 6 7 8 0 MULLION CENTERS IN FEET kawneer.com 1 2 3 4 5 6 7 MULLION CENTERS IN FEET ADMD150 8 METERS 0 © Kawneer Company, Inc., 2013 2 14 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.5 METERS C 13 1 15 4.5 MULLION HEIGHT IN FEET 14 .5 16 B 15 METERS 2 2-1/4" (57.2) 16 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS A SINGLE SPAN 2250 IG 28 DECEMBER, 2013 WIND LOAD CHARTS (1" INFILL) EC 97911-053 (SHEAR BLOCK) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) METERS 2 A 2 9 29 4.5 14 B 28 B C 26 E 10 9 2.5 8 7 METERS 3 2 6 5 1.5 MULLION HEIGHT IN FEET D 11 MULLION HEIGHT EQUAL EQUAL 3.5 6" (152.4) 12 8.5 27 4 MULLION HEIGHT 13 8 C 25 7.5 24 D 23 7 22 E 21 6.5 20 6 19 18 4 1 3 165127 & 162362 Steel 1 0 1 2 3 4 5 6 7 5 16 Ia = 7.223(300.6 x 104) Sa = 2.442(40.0 x 103) Is = 2.228(92.7 x 104) Ss = 1.456(23.9 x 103) .5 0 5.5 17 2 15 4.5 14 8 0 1 2 5 6 7 8 SINGLE SPAN TWIN SPAN 1 METERS 1.5 2 15 B 9 8.5 27 4 8 26 9 2.5 8 7 2 6 5 METERS 3 1.5 4 MULLION HEIGHT IN FEET 10 MULLION HEIGHT EQUAL EQUAL 3.5 3-3/4" (95.3) D E 2 28 MULLION HEIGHT C 12 1.5 1 29 4.5 13 .5 30 A 11 4 MULLION CENTERS IN FEET METERS 14 3 MULLION CENTERS IN FEET .5 16 MULLION HEIGHT IN FEET 1.5 1 25 7.5 24 23 7 22 A 21 6.5 20 6 19 B 18 1 3 165044 2 .5 1 5.5 17 I = 2.606(108.5 x 104) S = 1.382(22.7 x 103) 0 D C 16 15 5 E 4.5 14 0 1 2 3 4 5 6 7 8 0 MULLION CENTERS IN FEET 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD150 kawneer.com © Kawneer Company, Inc., 2013 15 MULLION HEIGHT IN FEET .5 30 METERS 1.5 METERS 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. METERS .5 16 TWIN SPAN Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SINGLE SPAN 2250 IG DECEMBER, 2013 EC 97911-053 29 WIND LOAD CHARTS (1" INFILL) (SHEAR BLOCK) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) METERS 1.5 .5 30 15 14 9 A 2.5 8 7 2 6 5 1.5 4 MULLION HEIGHT IN FEET 9 MULLION HEIGHT EQUAL EQUAL 3 3-3/4" (95.3) E D METERS 10 MULLION HEIGHT 3.5 C 11 1 3 165044 & 162362 Steel 1 3 4 5 6 7 25 8 C 7.5 24 D 23 7 22 E 21 6.5 20 6 19 18 5.5 5 16 Ia = 2.606(108.5 x 104) Sa = 1.382(22.7 x 103) Is = 2.228(92.7 x 104) Ss = 1.456(23.9 x 103) .5 2 B 26 17 2 1 15 4.5 14 8 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS 8 METERS 2 A B 13 12 C 11 D 10 E 1.5 2 9 B 28 8.5 27 4 8 26 3.5 3 9 2.5 8 7 2 6 5 1.5 MULLION HEIGHT IN FEET 14 1 29 4.5 MULLION HEIGHT EQUAL EQUAL 15 .5 30 7-1/2" (190.5) 1.5 MULLION HEIGHT 1 METERS .5 16 8.5 27 4 B 12 MULLION HEIGHT IN FEET 2 28 A 13 0 © Kawneer Company, Inc., 2013 1.5 1 29 4.5 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. METERS 2 25 C 24 7.5 D 23 7 E 22 6.5 21 20 6 19 18 4 1 3 .5 1 5.5 17 165139 2 I = 13.857(576.8 x 104) S = 3.705(60.7 x 103) 0 5 16 15 4.5 14 0 1 2 3 4 5 6 7 8 0 1 2 3 4 5 6 7 MULLION CENTERS IN FEET MULLION CENTERS IN FEET kawneer.com METERS 1 TWIN SPAN ADMD150 8 METERS .5 16 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN 9 1 2 3 12 11 10 4 5 6 7 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) 2 30 15 4.5 14 13 4 B A 3.5 C D 3 8 E 2.5 7 2 6 5 1.5 4 3 1 2 .5 1 I = 6.327(263.3 x 104) S = 2.409(39.5 x 103) 165064 0 MULLION CENTERS IN FEET 8 ADMD150 .5 METERS 0 1 1 20 2 3 1.5 25 24 21 4 5 2 29 9 28 A 27 6 8.5 26 8 C B 7.5 23 22 7 D 6.5 19 E 6 18 17 5.5 16 5 15 4.5 7 kawneer.com Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. WIND LOAD CHARTS (1" INFILL) METERS 1.5 MULLION HEIGHT IN FEET 2250 IG © Kawneer Company, Inc., 2013 0 1 MULLION HEIGHT EQUAL EQUAL METERS 5-1/4" (133.4) .5 MULLION HEIGHT 16 METERS SINGLE SPAN Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION HEIGHT IN FEET 30 DECEMBER, 2013 EC 97911-053 (SHEAR BLOCK) TWIN SPAN 14 MULLION CENTERS IN FEET 8 2250 IG DECEMBER, 2013 EC 97911-053 31 WIND LOAD CHARTS (1/4" INFILL) (TYPE “A” SCREW SPLINE) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) METERS .5 16 1 1.5 SINGLE SPAN METERS 2 .5 16 1 1.5 15 15 2 A 4.5 4.5 14 13 B 13 4 9 3 D E 8 2.5 7 2 6 5 MULLION HEIGHT IN FEET B C 5-1/4" (133.4) 10 3.5 6-3/4" (171.45) A 11 METERS 12 MULLION HEIGHT 12 1.5 4 C 11 3.5 D 10 3 E 9 2.5 8 7 METERS 14 MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN 2 6 5 1.5 4 4 1 3 1 3 2 165257 & 165016 165277 & 166010 I = 5.203(216.6 x 104) S = 1.828(30.0 x 103) I = 10.964(456.4 x 104) S = 2.941(48.2 x 103) .5 1 2 .5 1 0 0 1 0 2 3 4 5 6 7 0 8 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET MULLION CENTERS IN FEET SINGLE SPAN SINGLE SPAN METERS 1 METERS 1.5 2 15 1 1.5 2 15 4.5 13 13 4 2.5 E 7 2 6 5 MULLION HEIGHT IN FEET D 8 5-1/4" (133.4) 3 C 9 6-3/4" (171.45) 3.5 B 10 MULLION HEIGHT A 11 1.5 4 4 B 12 METERS 12 4.5 A 14 14 MULLION HEIGHT IN FEET .5 16 C 11 3.5 D 10 3 E 9 2.5 8 7 2 6 5 1.5 4 1 3 2 .5 1 1 3 165263 165274 I = 5.381(224.0 x 104) S = 2.058(33.7 x 103) I = 12.108(504.0 x 104) S = 3.641(59.7 x 103) 0 2 .5 1 0 0 1 2 3 4 5 6 7 0 8 MULLION CENTERS IN FEET kawneer.com 1 2 3 4 5 6 7 MULLION CENTERS IN FEET ADMD150 8 METERS .5 16 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. (TYPE “B” SCREW SPLINE) 2250 IG 32 DECEMBER, 2013 WIND LOAD CHARTS (1/4" INFILL) EC 97911-053 (SHEAR BLOCK) A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) METERS 1 1.5 METERS 2 15 1 2 9 28 14 2.5 E 7 2 6 5 1.5 MULLION HEIGHT IN FEET D 8 MULLION HEIGHT EQUAL EQUAL C METERS 3 5-1/4" (133.4) B MULLION HEIGHT 3.5 11 9 8 26 A 10 8.5 27 4 12 A 25 7.5 24 23 7 22 B 21 1 3 6.5 20 6 19 C 18 4 5.5 17 165264 2 1 D 16 I = 5.318(221.4 x 104) S = 1.996(32.7 x 103) .5 15 0 5 E 4.5 14 3 4 5 6 7 8 0 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET SINGLE SPAN TWIN SPAN METERS .5 16 1 METERS 1.5 2 15 13 1 1.5 2 A 9 29 4.5 A 14 .5 30 28 B 12 8.5 B 27 4 8 26 C D 7 2 6 5 1.5 MULLION HEIGHT IN FEET 2.5 8 MULLION HEIGHT EQUAL EQUAL 9 5-1/4" (133.4) 3 E MULLION HEIGHT 10 3.5 METERS 11 25 7.5 24 C 23 7 22 21 D 6.5 E 6 20 19 18 4 1 3 165264 & 162362 Steel 2 .5 1 0 0 1 2 3 4 5 6 7 5.5 17 Ia = 5.318(221.4 x 104) Sa = 1.996(32.7 x 103) Is = 2.228(92.7 x 104) Ss = 1.456(23.9 x 103) 8 5 16 15 4.5 14 0 MULLION CENTERS IN FEET 1 2 3 4 5 6 7 8 MULLION CENTERS IN FEET ADMD150 kawneer.com © Kawneer Company, Inc., 2013 2 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1 MULLION CENTERS IN FEET METERS 0 MULLION HEIGHT IN FEET 1.5 29 4.5 13 MULLION HEIGHT IN FEET .5 30 METERS .5 16 TWIN SPAN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. SINGLE SPAN © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. MULLION HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0 1 kawneer.com 1 2 3 4 2250 IG 1.5 14 13 12 11 10 5 6 7 A = 20 PSF (960) B = 30 PSF (1440) C = 40 PSF (1920) D = 50 PSF (2400) E = 60 PSF (2880) 2 30 15 A 4.5 B 4 C D 3.5 E 3 9 8 2.5 7 2 5 6 1.5 4 3 1 2 .5 1 I = 11.101(462.1 x 104) S = 3.211(52.6 x 103) 165279 0 MULLION CENTERS IN FEET 8 ADMD150 .5 0 1 1 2 3 1.5 29 28 26 B 23 C 22 D 20 4 5 6 7 21 6.5 19 E 6 18 17 5.5 16 5 15 14 4.5 MULLION CENTERS IN FEET 7 8 METERS EC 97911-053 MULLION HEIGHT IN FEET METERS MULLION HEIGHT EQUAL EQUAL SINGLE SPAN 6-3/4" (171.45) .5 MULLION HEIGHT 16 METERS DECEMBER, 2013 33 WIND LOAD CHARTS (1/4" INFILL) (SHEAR BLOCK) TWIN SPAN METERS 2 A 9 27 8.5 8 25 24 7.5 2250 IG 34 DECEMBER, 2013 DEADLOAD CHARTS EC 97911-053 A - 1/4" GLASS (1/8 POINT LOADING) B - 1/4" GLASS (1/4 POINT LOADING) 4-1/2" (114.3) B - 1" GLASS (1/8 POINT LOADING) C - 1" GLASS (1/4 POINT LOADING) 165115 165162 I = 0.405(16.9 x 104) S = 0.263(4.3 x 103) I = 0.373(14.5 x 104) S = 0.242(4.0 x 103) METERS .5 13 1 METERS 1.5 2 1 1.5 2 12 3.5 11 10 2 6 C METERS 2.5 7 5 GLASS HEIGHT IN FEET B 8 10 3 A 9 1.5 4 1 3 3.5 11 3 9 A 8 2.5 B 7 2 6 5 1.5 C 4 1 3 2 2 .5 .5 1 1 0 1 2 3 4 5 6 7 8 0 1 2 4 5 SPAN IN FEET 5-1/4" (133.4) 5-1/4" (133.4) 1 6 7 8 165259 165221 I = 0.475(19.8 x 104) S = 0.306(5.0 x 103) I = 1.202(50.0 x 104) S = 1.053(17.3 x 103) METERS .5 13 3 SPAN IN FEET METERS 1.5 2 12 1 .5 13 1.5 2 A 12 10 GLASS HEIGHT IN FEET B 2.5 7 2 6 5 METERS 8 10 3 A 9 1.5 4 1 3 3.5 11 3 9 B 8 2.5 7 2 6 5 1.5 4 1 3 2 METERS 3.5 11 2 .5 .5 1 1 0 0 0 1 2 3 4 5 6 7 8 SPAN IN FEET 0 1 2 3 4 5 6 7 8 SPAN IN FEET ADMD150 kawneer.com © Kawneer Company, Inc., 2013 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0 GLASS HEIGHT IN FEET METERS 12 GLASS HEIGHT IN FEET .5 13 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 4-1/2" (114.3) 2250 IG DECEMBER, 2013 EC 97911-053 35 DEADLOAD CHARTS A - 1/4" GLASS (1/8 POINT LOADING) B - 1/4" GLASS (1/4 POINT LOADING) 5-1/4" (133.4) B - 1" GLASS (1/8 POINT LOADING) C - 1" GLASS (1/4 POINT LOADING) 165262 165223 I = 0.457(19.0 x 104) S = 0.280(4.6 x 103) I = 0.546(22.7 x 104) S = 0.359(5.9 x 103) METERS 1 .5 13 METERS 1.5 2 GLASS HEIGHT IN FEET 9 7 2 6 5 METERS 2.5 8 1.5 4 1 3 3.5 B 10 3 B A 11 A 10 GLASS HEIGHT IN FEET 2 12 3.5 11 3 9 2.5 8 7 2 6 5 1.5 4 1 3 2 2 .5 .5 1 1 0 0 0 1 2 3 4 5 6 7 8 0 1 2 4 5 6 SPAN IN FEET 6" (152.4) 6" (152.4) 1 7 8 165111 165102 I = 0.463(19.3 x 104) S = 0.299(4.9 x 103) I = 0.447(18.6 x 104) S = 0.276(4.5 x 103) METERS METERS 1.5 2 1 .5 13 12 1.5 2 12 A 11 3.5 GLASS HEIGHT IN FEET 7 2 6 5 METERS 2.5 8 1.5 4 1 3 A B 10 3 C 9 3.5 11 B 10 GLASS HEIGHT IN FEET 3 SPAN IN FEET .5 13 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 1.5 3 C 9 2.5 8 7 2 6 5 1.5 4 1 3 2 2 .5 .5 1 1 0 0 1 2 3 4 5 6 7 0 8 0 SPAN IN FEET kawneer.com METERS 12 1 .5 13 1 2 3 4 5 SPAN IN FEET ADMD150 6 7 8 METERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 5-1/4" (133.4) 2250 IG 36 DECEMBER, 2013 DEADLOAD CHARTS EC 97911-053 A - 1/4" GLASS (1/8 POINT LOADING) B - 1/4" GLASS (1/4 POINT LOADING) 6-3/4" (171.45) B - 1" GLASS (1/8 POINT LOADING) C - 1" GLASS (1/4 POINT LOADING) 165275 165250 I = 0.589(24.5 x 104) S = 0.356(5.8 x 103) I = 1.882(79.3 x 104) S = 1.651(27.1 x 103) METERS METERS 13 1 1.5 2 13 1.5 2 B 12 12 A 11 3.5 10 GLASS HEIGHT IN FEET 3 9 7 2 6 5 METERS 2.5 8 1.5 4 1 3 3.5 11 B 10 3 9 2.5 8 7 2 6 5 1.5 4 1 3 2 2 .5 .5 1 1 0 1 2 3 4 5 6 7 8 0 1 2 4 5 SPAN IN FEET 6-3/4" (171.45) 6-3/4" (171.45) 1 7 8 165272 165253 I = 0.654(27.2 x 104) S = 0.406(6.7 x 103) METERS METERS .5 6 I = 0.539(22.4 x 104) S = 0.319(5.2 x 103) 1.5 2 1 .5 13 13 1.5 2 12 12 A 11 3.5 10 GLASS HEIGHT IN FEET 3 9 7 2 6 5 METERS 2.5 8 1.5 4 1 3 3.5 11 B 10 GLASS HEIGHT IN FEET 3 SPAN IN FEET 3 9 A B 8 2.5 7 2 6 5 1.5 4 1 3 2 2 .5 .5 1 1 0 0 0 1 2 3 4 5 6 7 0 8 1 2 3 4 5 6 7 8 SPAN IN FEET SPAN IN FEET ADMD150 kawneer.com © Kawneer Company, Inc., 2013 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0 METERS GLASS HEIGHT IN FEET 1 .5 METERS .5 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 6-3/4" (171.45) 2250 IG DECEMBER, 2013 EC 97911-053 37 DEADLOAD CHARTS A - 1/4" GLASS (1/8 POINT LOADING) B - 1/4" GLASS (1/4 POINT LOADING) 7-1/2" (190.5) B - 1" GLASS (1/8 POINT LOADING) C - 1" GLASS (1/4 POINT LOADING) 165133 165069 I = 0.583(24.3 x 104) S = 0.355(5.8 x 103) I = 0.332(13.8 x 104) S = 0.527(8.6 x 103) METERS 1 .5 13 METERS 1.5 2 12 1.5 2 10 GLASS HEIGHT IN FEET 3 9 C 7 2 6 5 METERS 2.5 8 1.5 4 1 3 3.5 11 3 9 A 8 2.5 B 7 2 6 5 1.5 C 4 1 3 2 2 .5 .5 1 1 0 0 1 2 3 4 5 6 7 8 0 1 2 5 6 7-1/2" (190.5) 7-1/2" (190.5) 1 7 8 165137 165057 I = 0.534(22.2 x 104) S = 0.318(5.2 x 103) I = 0.251(10.5 x 104) S = 0.383 (6.3 x 103) METERS 1.5 2 1 .5 13 1.5 2 12 12 A 11 3.5 10 GLASS HEIGHT IN FEET 9 2.5 8 7 C 6 2 5 1.5 4 1 3 A 10 3 B 3.5 11 METERS GLASS HEIGHT IN FEET 4 SPAN IN FEET METERS © Kawneer Company, Inc., 2013 3 SPAN IN FEET .5 13 3 9 2.5 8 7 2 B 6 5 1.5 4 C 3 1 2 2 .5 .5 1 1 0 0 0 1 2 3 4 5 6 7 0 8 SPAN IN FEET kawneer.com METERS 3.5 B 10 GLASS HEIGHT IN FEET 1 12 A 11 0 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. .5 13 1 2 3 4 5 SPAN IN FEET ADMD150 6 7 8 METERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 7-1/2" (190.5) 2250 IG DECEMBER, 2013 THERMAL CHARTS EC 97911-053 Project Specific U-Factor Example Calculation 15'-8" F.W. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2'-0" D.L.O. 9'-6" F.H. 7'-0" D.L.O. 5'-0" D.L.O. = 0.42 Btu/(ft2·h·°F) Example Glass U-Factor Total Daylight (Vision) Area = 3(5' x 7') + 3(5' x 2') = 135 ft2 Projected Total Area = 15'-8" x 9'-6" = 148.83 ft2 Percent of Vision Glass = (Total Daylight Area ÷ Projected Total Area)100 = (135 ÷ 148.83)100 = 91% System U-factor vs Percent of Glass Area 0.40 0.30 70 75 80 85 Vision Area / Total Area % Based on 91% glass and center of glass U-factor of 0.42 system U-factor is equal to 0.49 Btu/hr·ft2·°F ADMD150 kawneer.com © Kawneer Company, Inc., 2013 0.50 0.49 0.20 90 91% COG U-factor 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.60 System U-factor (BTU/hr/ft2/°F) (N E L ) P ign M es A D X or E ot f 0.70 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 0.80 95 38 2250 IG DECEMBER, 2013 EC 97911-053 39 THERMAL CHARTS System U-Factors for Vision Glass (Captured Shear Block Option) 1.05 COG U-factor (6.00) 1.00 0.95 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 0.90 (5.00) 0.85 System U-factor 0.60 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 System U-factor Btu 2 hr·ft ·°F 0.65 W 2 m ·°C (4.50) 0.75 0.70 W 2 m ·°C 0.80 (4.00) (3.50) 0.55 (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) 95 (3.00) 0.50 0.45 (2.50) 0.40 0.35 (2.00) 0.30 90 85 80 75 70 Vision Area / Total Area (%) Note: Values in parentheses are metric. COG = Center Of Glass. Charts are generated per AAMA 507. System U-Factor for Vision Glass (Captured Ribbon Window Option) 0.95 COG U-factor (5.50) 0.90 (5.00) 0.85 0.80 (4.50) 0.75 0.70 0.60 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.55 (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) 0.50 (3.00) (2.50) 0.40 0.35 (2.00) 0.30 90 85 80 Vision Area / Total Area (%) kawneer.com (3.50) 0.45 0.25 95 (4.00) Btu 2 hr·ft ·°F 0.65 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. (5.50) ADMD150 75 70 (1.50) 0.80 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 95 90 85 80 ADMD150 75 70 0.00 Vision Area / Total Area (%) Charts are generated per AAMA 507 kawneer.com © Kawneer Company, Inc., 2013 COG SHGC Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. THERMAL CHARTS (Captured Shear Block Option) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2250 IG System SHGC 40 DECEMBER, 2013 EC 97911-053 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-053 COG VT 0.75 0.70 0.45 0.45 0.40 0.40 0.35 0.35 0.30 kawneer.com 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 95 90 85 80 Vision Area / Total Area (%) Charts are generated per AAMA 507 ADMD150 75 70 0.00 System VT DECEMBER, 2013 2250 IG THERMAL CHARTS (Captured Shear Block Option) System Visible Transmittance (VT) vs Percent of Vision Area 0.80 0.75 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 41 COG SHGC 0.75 0.75 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 95 90 85 80 ADMD150 75 70 0.00 Vision Area / Total Area (%) Charts are generated per AAMA 507 kawneer.com © Kawneer Company, Inc., 2013 0.80 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. THERMAL CHARTS (Captured Ribbon Window Option) Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 2250 IG System SHGC 42 DECEMBER, 2013 EC 97911-053 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. EC 97911-053 COG VT 0.75 0.70 0.45 0.45 0.40 0.40 0.35 0.35 0.30 kawneer.com 0.30 0.25 0.25 0.20 0.20 0.15 0.15 0.10 0.10 0.05 0.05 95 90 85 80 Vision Area / Total Area (%) Charts are generated per AAMA 507 ADMD150 75 70 0.00 System VT DECEMBER, 2013 2250 IG THERMAL CHARTS (Captured Ribbon Window Option) System Visible Transmittance (VT) vs Percent of Vision Area 0.80 0.75 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 43 2250 IG DECEMBER, 2013 THERMAL PERFORMANCE MATRIX (NFRC SIZE) EC 97911-053 Captured Shear Block Option Thermal Transmittance1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.64 0.46 0.62 0.44 0.60 0.42 0.59 0.40 0.57 0.38 0.56 0.36 0.54 0.34 0.52 0.32 0.51 0.30 0.49 0.28 0.47 0.26 0.46 0.24 0.44 0.22 0.43 0.20 0.41 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.70 0.75 0.68 0.70 0.65 0.70 0.63 0.65 0.61 0.65 0.59 0.60 0.56 0.60 0.54 0.55 0.52 0.55 0.50 0.50 0.47 0.50 0.45 0.45 0.42 0.45 0.41 0.40 0.38 0.40 0.36 0.35 0.33 0.35 0.32 0.30 0.29 0.30 0.27 0.25 0.24 0.25 0.23 0.20 0.20 0.20 0.18 0.15 0.15 0.15 0.14 0.10 0.11 0.10 0.09 0.05 0.06 0.05 0.05 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). ADMD150 kawneer.com © Kawneer Company, Inc., 2013 SHGC Matrix 2 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 44 2250 IG DECEMBER, 2013 EC 97911-053 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Captured Ribbon Window Option Thermal Transmittance1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.65 0.46 0.63 0.44 0.61 0.42 0.60 0.40 0.58 0.38 0.57 0.36 0.55 0.34 0.53 0.32 0.52 0.30 0.50 0.28 0.49 0.26 0.47 0.24 0.46 0.22 0.44 0.20 0.42 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. Glass U-Factor 3 Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.68 0.75 0.66 0.70 0.64 0.70 0.62 0.65 0.59 0.65 0.57 0.60 0.55 0.60 0.53 0.55 0.50 0.55 0.48 0.50 0.46 0.50 0.44 0.45 0.42 0.45 0.40 0.40 0.37 0.40 0.35 0.35 0.33 0.35 0.31 0.30 0.28 0.30 0.26 0.25 0.24 0.25 0.22 0.20 0.20 0.20 0.18 0.15 0.15 0.15 0.13 0.10 0.11 0.10 0.09 0.05 0.06 0.05 0.04 © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. SHGC Matrix 2 NOTE: For glass values that are not listed, linear interpolation is permitted. 1. U-Factors are determined in accordance with NFRC 100. 2. SHGC and VT values are determined in accordance with NFRC 200. 3. Glass properties are based on center of glass values and are obtained from your glass supplier. 4. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). kawneer.com ADMD150 45 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely. Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor. 2250 IG BLANK PAGE ADMD150 kawneer.com © Kawneer Company, Inc., 2013 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement. 46 DECEMBER, 2013 EC 97911-053