1600 Wall System™3 - Architectural Detail Manual

1600 WALL SYSTEMTM3
JULY, 2014
EC 97911-063
FEATURES
Features
• 1600 Wall SystemTM3 has a 2-1/2" (63.5) sight line
• Standard 6" (152.4) or 7-1/2" (190.5) depth systems are compatible with SystemTM1
and SystemTM2
• Inside glazed verticals utilize the IsoStrutTM thermal barrier to provide
superior structural and thermal performance
• Integral vertical exterior cover and thermal barrier reduce installed cost
• Horizontals utilize a thermal separator and pressure plate to allow for
glazing or re-glazing from the exterior
• Standard infill options are 1/8" (3.2), 1/4" (6.4) and 1" (25.4)
• Thermally Broken by means of a continuous 1/4" (6.4) low conductance spacer
• Concealed fastener joinery creates smooth, monolithic appearance
• Shear block fabrication method
• Standard 90 and 135 degree inside and outside corners available
• Offers integrated entrance framing systems
• Peroxide-cure high performance EPDM silicone compatible glazing materials for
long-lasting seals
• Two color option
•PermanodicTM anodized finishes in seven choices
• Painted finishes in standard and custom choices
Optional Features
• Steel reinforcing available
• Integrates with Kawneer windows and concealed GLASSventTM for curtain wall
• 1600 PowerWallTM solar photovoltaic (PV) infill in lieu of glass
© Kawneer Company, Inc,, 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
• 1600 Wall SystemTM3 is an inside / outside glazed captured curtain wall
Product Applications
• Ideal for low-rise to high-rise curtain wall applications where inside glazing and high
performance is desired
For specific product applications,
Consult your Kawneer representative.
kawneer,com
ADMD030EN
1
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
1600 WALL SYSTEMTM3
BLANK PAGE
ADMD030EN
kawneer,com
© Kawneer Company, Inc,, 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
2
JULY, 2014
EC 97911-063
1600 WALL SYSTEMTM3
JULY, 2014
EC 97911-063
3
INDEX
PICTORIAL VIEW..................................................................................... 5
TYPICAL 1/4 SIZE DETAILS................................................................. 6-7
ENTRANCE ADAPTERS.......................................................................... 8
CORNERS................................................................................................. 8
ANCHORING............................................................................................ 9
WIND LOAD CHARTS....................................................................... 10-13
DEADLOAD CHARTS....................................................................... 14-16
THERMAL CHARTS.......................................................................... 17-21
LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED
ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT
CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR
GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR.
Metric (SI) conversion figures are included throughout these details for reference.
Numbers in parentheses (
) are millimeters unless otherwise noted.
The following metric (SI) units are found in these details:
m –meter
cm – centimeter
mm –millimeter
s –second
Pa –pascal
MPa –megapascal
© Kawneer Company, Inc,, 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded
and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be
modified to expand design flexibility. Please contact your Kawneer representative for further assistance.
Kawneer reserves the right to change configurations without prior notice when deemed necessary
for product improvement.
kawneer,com
ADMD030EN
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
1600 WALL SYSTEMTM3
BLANK PAGE
ADMD030EN
kawneer,com
© Kawneer Company, Inc,, 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
4
JULY, 2014
EC 97911-063
© Kawneer Company, Inc,, 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
JULY, 2014
kawneer,com
1600 WALL SYSTEMTM3
EC 97911-063
PICTORIAL VIEW
ADMD030EN
5
2
3
7
13
7A
13A
4
9
8
12
10
ELEVATION IS NUMBER KEYED TO DETAILS
13
11
ADMD030EN
7
1
7A
2
OPTIONAL
HORIZONTAL
5
13A
11
6
3
12
10
NOTE:
6" SYSTEM SHOWN, 7-1/2" SIMILAR.
INSIDE GLAZED IsoStrutTM VERTICALS SHOWN.
8
4
ALTERNATE
JAMB
5
9
6
kawneer,com
© Kawneer Company, Inc,, 2014
TYPICAL 1/4 SIZE DETAILS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
1600 WALL SYSTEMTM3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
6
JULY, 2014
EC 97911-063
SCALE 3" = 1'-0"
1
© Kawneer Company, Inc,, 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
JULY, 2014
7
14
13
13
kawneer,com
1600 WALL SYSTEMTM3
EC 97911-063
2
7A
4
12
10
6
ELEVATION IS NUMBER KEYED TO DETAILS
14
12
11
ADMD030EN
7
TYPICAL1/4 SIZE DETAILS
SCALE 3" = 1'-0"
1
3
9
8
7
1
7A
2
OPTIONAL
HORIZONTAL
5
11
3
10
NOTES:
6" SYSTEM SHOWN, 7-1/2" SIMILAR.
APPLIED PRESSURE PLATE OPTION SHOWN.
8
4
5
9
6
2
3
1
2
1
1
OUTSIDE 90° CORNER
OUTSIDE 135° CORNER
ADMD030EN
3
ELEVATION IS NUMBER KEYED TO DETAILS
NOTE:
OFFSET PIVOT/BUTT HUNG ENTRANCE SHOWN.
ALSO AVAILABLE FOR CENTER HUNG
7/8"
(22.2)
INSIDE 90° CORNER
INSIDE 135° CORNER
kawneer,com
© Kawneer Company, Inc,, 2014
ENTRANCE ADAPTERS / CORNERS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
1600 WALL SYSTEMTM3
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
8
JULY, 2014
EC 97911-063
SCALE 3" = 1'-0"
ENTRANCE ADAPTERS
2
CORNERS
© Kawneer Company, Inc,, 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
JULY, 2014
kawneer,com
1600 WALL SYSTEMTM3
EC 97911-063
ANCHORING
ADMD030EN
9
10
1600 WALL SYSTEMTM3
JULY, 2014
WIND LOAD CHARTS
EC 97911-063
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves
are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM
15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined
through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design.
A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your
Kawneer representative for additional information.
(960 Pa)
(1440 Pa)
(1920 Pa)
(2400 Pa)
(2880 Pa)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
A = 20 PSF
B = 30 PSF
C = 40 PSF
D = 50 PSF
E = 60 PSF
SINGLE SPAN
WIDTH IN METERS
.5
1
1.5
2
15
14
A
11
B
10
3
C
D 2.5
9
8
E
7
2
6
5
1.5
3
4
5
6
WIDTH IN FEET
7
8
SINGLE SPAN
WIDTH IN METERS
.5
1
1.5
2
15
A
14
3.5
11
C
10
D3
9
E
2.5
8
7
2
6
5
4
MULLION HEIGHT
HEIGHT IN FEET
B
12
HEIGHT IN METERS
4
13
1.5
1
2
3
4
5
6
7
163201
8
WIDTH IN FEET
ADMD030EN
kawneer,com
© Kawneer Company, Inc,, 2014
2
1
163200
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
4
3.5
MULLION HEIGHT
HEIGHT IN FEET
12
HEIGHT IN METERS
4
13
1600 WALL SYSTEMTM3
JULY, 2014
EC 97911-063
11
WIND LOAD CHARTS
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves
are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM
15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined
through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design.
A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your
Kawneer representative for additional information.
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
A = 20 PSF
B = 30 PSF
C = 40 PSF
D = 50 PSF
E = 60 PSF
SINGLE SPAN
WIDTH IN METERS
.5
1
1.5
2
15
14
3.5
11
A
10
B
9
C 2.5
D
E
2
8
6
5
4
3
MULLION HEIGHT
HEIGHT IN FEET
12
HEIGHT IN METERS
4
13
7
163204
1.5
2
1
3
4
5
6
WIDTH IN FEET
7
8
SINGLE SPAN
WIDTH IN METERS
.5
1
1.5
2
15
HEIGHT IN FEET
12
B 3.5
11
C
10
D
9
3
E 2.5
8
7
2
6
5
4
4
1.5
1
2
3
4
5
6
7
8
WIDTH IN FEET
kawneer,com
MULLION HEIGHT
A
13
HEIGHT IN METERS
14
© Kawneer Company, Inc,, 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
(960 Pa)
(1440 Pa)
(1920 Pa)
(2400 Pa)
(2880 Pa)
ADMD030EN
163205
12
1600 WALL SYSTEMTM3
JULY, 2014
WIND LOAD CHARTS
EC 97911-063
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves
are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM
15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined
through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design.
A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your
Kawneer representative for additional information.
(960 Pa)
(1440 Pa)
(1920 Pa)
(2400 Pa)
(2880 Pa)
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
A = 20 PSF
B = 30 PSF
C = 40 PSF
D = 50 PSF
E = 60 PSF
SINGLE SPAN
WIDTH IN METERS
.5
1
1.5
2
15
12
A
11
10
B
9
C
8
D
E
7
6
5
4
3.5
3
2.5
MULLION HEIGHT
4
13
HEIGHT IN METERS
HEIGHT IN METERS
14
2
163208
1.5
1
2
3
4
5
6
7
8
SINGLE SPAN
WIDTH IN METERS
.5
1
1.5
2
15
14
A
B
11
10
D
9
E
8
7
3
2.5
2
6
5
4
3.5
C
MULLION HEIGHT
HEIGHT IN FEET
12
HEIGHT IN METERS
4
13
1.5
1
2
3
4
5
6
WIDTH IN FEET
7
163209
8
ADMD030EN
kawneer,com
© Kawneer Company, Inc,, 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
WIDTH IN FEET
1600 WALL SYSTEMTM3
JULY, 2014
EC 97911-063
13
WIND LOAD CHARTS
SINGLE SPAN
TWIN SPAN
WIDTH IN METERS
WIDTH IN METERS
1.5
2
.5
4.4
14
12
3.3
11
10
A
9
3
6
B 2.2
C
D
2
E
5
1.5
8
7
HEIGHT IN METERS
4
13
25
7.5
24
23
7
A
22
6.5
21
20
6
19
B 5.5
17
5
.5
163038
0
2
1
3
4
5
6
7
8
A = 20 PSF
B = 30 PSF
C = 40 PSF
D = 50 PSF
E = 60 PSF
WIDTH IN METERS
1
1.5
4.5
14
D
13
E
12
SINGLE SPAN
.5
C
15
WIDTH IN FEET
(960 Pa)
(1440 Pa)
(1920 Pa)
(2400 Pa)
(2880 Pa)
0
2
1
3
.5
17
29
12
3.3
11
B
10
C
9
D
8
E
7
3
2.2
2
6
5
6
7
1
1.5
9
A
27
25
7.5
24
23
B
22
20
C
19
2
5.5
5
E
15
4.5
14
.5
1
4
13
0
1
2
3
4
5
6
7
8
6
D
16
1
7
6.5
21
17
1.5
8.5
8
26
18
4
3
8
2
28
HEIGHT IN FEET
A
HEIGHT IN METERS
4
13
MULLION HEIGHT
4.4
14
MULLION HEIGHT
EQUAL
EQUAL
30
15
5
WIDTH IN METERS
18
5
4
WIDTH IN FEET
4
TWIN SPAN
2
16
HEIGHT IN FEET
8
26
18
1
© Kawneer Company, Inc,, 2014
8.5
27
1
2
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
9
16
3
163039
WIDTH IN FEET
kawneer,com
2
28
4
0
1.5
29
HEIGHT IN FEET
15
MULLION HEIGHT
EQUAL
EQUAL
5
16
MULLION HEIGHT
17
0
1
30
12
0
1
2
3
4
5
6
WIDTH IN FEET
ADMD030EN
HEIGHT IN METERS
1
7
8
HEIGHT IN METERS
.5
18
HEIGHT IN FEET
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves
are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM
15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined
through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design.
A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your
Kawneer representative for additional information.
1600 WALL SYSTEMTM3
14
JULY, 2014
DEADLOAD CHARTS
EC 97911-063
Horizontal or deadload limitations are based upon 1/8" maximum deflection at the center of an intermediate horizontal member.
The accompanying charts are calculated for 1/4" and 1" thick glass supported on two setting blocks placed at the loading points shown.
1/4" GLASS
1" GLASS
WIDTH IN METERS
WIDTH IN METERS
1
1.5
2
12
1.5
2
10
B
5
1.5
4
A
3
163004
1
2
0
2
1
7
6
5
B
5
1.5
A
4
1
0.5
1
0
8
0
0
WIDTH IN FEET
2
1
4
3
7
6
5
1/4" GLASS
1" GLASS
WIDTH IN METERS
1
1.5
2
.5
13
12
8
WIDTH IN FEET
WIDTH IN METERS
.5
13
4
3
2
6
2
0
0
2.5
8
7
3
0.5
1
3
9
1
1.5
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
2
6
HEIGHT IN FEET
2.5
8
7
HEIGHT IN METERS
3
9
3.5
11
HEIGHT IN METERS
10
2
12
3.5
11
10
10
7
2
B
6
5
1.5
A
4
163005
1
3
2
3
9
2.5
8
7
2
B
6
5
1.5
A
4
1
3
2
0.5
1
HEIGHT IN FEET
2.5
8
HEIGHT IN METERS
3
9
3.5
11
0.5
1
0
0
0
0
1
2
3
4
5
6
7
8
0
0
WIDTH IN FEET
ADMD030EN
HEIGHT IN METERS
HEIGHT IN FEET
1
12
3.5
11
HEIGHT IN FEET
.5
13
1
2
3
4
5
6
7
8
WIDTH IN FEET
kawneer,com
© Kawneer Company, Inc,, 2014
.5
13
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
A = 1/4 POINT LOADING
B = 1/8 POINT LOADING
1600 WALL SYSTEMTM3
JULY, 2014
EC 97911-063
15
DEADLOAD CHARTS
Horizontal or deadload limitations are based upon 1/8" maximum deflection at the center of an intermediate horizontal member.
The accompanying charts are calculated for 1/4" and 1" thick glass supported on two setting blocks placed at the loading points shown.
1/4" GLASS
1" GLASS
WIDTH IN METERS
WIDTH IN METERS
.5
13
1
1.5
2
12
A
2
6
5
1.5
4
163010
163004
1
2
1
7
6
5
WIDTH IN FEET
A
6
5
1.5
4
1
0.5
1
0
8
0
0
1
2
4
3
5
7
6
1" GLASS
WIDTH IN METERS
1.5
2
.5
13
12
8
WIDTH IN FEET
1/4" GLASS
1
2
B
WIDTH IN METERS
.5
13
4
3
2.5
8
7
2
0
0
3
9
3
0.5
0
3.5
HEIGHT IN METERS
2.5
8
7
HEIGHT IN FEET
9
2
1
1.5
2
12
3.5
3
9
A
8
2.5
B
7
2
6
5
1.5
4
10
163010
163005
1
3
2
0
1
2
3
4
5
6
WIDTH IN FEET
7
A
8
2.5
7
B
6
2
5
1.5
4
1
2
0.5
1
0
0
0
3
9
3
0.5
1
HEIGHT IN FEET
10
3.5
11
HEIGHT IN METERS
11
HEIGHT IN FEET
2
10
3
B
3
© Kawneer Company, Inc,, 2014
1.5
11
HEIGHT IN METERS
HEIGHT IN FEET
10
1
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
1
12
3.5
11
kawneer,com
.5
13
8
0
0
ADMD030EN
1
2
3
4
5
6
WIDTH IN FEET
7
8
HEIGHT IN METERS
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
A = 1/4 POINT LOADING
B = 1/8 POINT LOADING
1600 WALL SYSTEMTM3
16
JULY, 2014
DEADLOAD CHARTS
EC 97911-063
Horizontal or deadload limitations are based upon 1/8" maximum deflection at the center of an intermediate horizontal member.
The accompanying charts are calculated for 1/4" and 1" thick glass supported on two setting blocks placed at the loading points shown.
1/4" GLASS
1" GLASS
WIDTH IN METERS
WIDTH IN METERS
1
1.5
2
12
1.5
2
7
2
A
6
5
1.5
4
163025
2
0
2
1
5
7
6
WIDTH IN FEET
1.5
1
0.5
1
0
8
0
0
2
1
3
4
7
6
5
1/4" GLASS
1" GLASS
WIDTH IN METERS
1
1.5
2
.5
13
1
1.5
2
12
3.5
11
10
10
A
2
6
5
1.5
4
163026
1
3
2
0
1
2
3
4
5
6
7
2.5
8
7
2
A
6
5
1.5
4
1
2
0.5
1
0
0
0
3
B
9
3
0.5
1
HEIGHT IN FEET
2.5
8
7
HEIGHT IN METERS
3
9
3.5
11
B
8
0
0
WIDTH IN FEET
ADMD030EN
HEIGHT IN METERS
12
8
WIDTH IN FEET
WIDTH IN METERS
.5
13
4
3
A
5
2
0
0
2
6
3
0.5
1
2.5
7
4
1
3
B
8
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
2.5
8
3
9
HEIGHT IN METERS
9
10
HEIGHT IN FEET
3
B
3.5
11
HEIGHT IN METERS
10
HEIGHT IN FEET
1
12
3.5
11
HEIGHT IN FEET
.5
13
1
2
3
4
5
6
WIDTH IN FEET
7
8
kawneer,com
© Kawneer Company, Inc,, 2014
.5
13
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
A = 1/4 POINT LOADING
B = 1/8 POINT LOADING
1600 WALL SYSTEMTM3
JULY, 2014
EC 97911-063
THERMAL CHARTS
VISION
2-1/2" Typ.
3'-0"
D.L.O.
4'-0"
D.L.O.
VISION
6'-0"
D.L.O.
SPANDREL
9'-0"
D.L.O.
31'-3"
SPANDREL
8'-0"
D.L.O.
2-1/2" Typ.
VISION
5'-0"
D.L.O.
Vision Area
© Kawneer Company, Inc,, 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
Generic Project Specific U-factor Example Calculation
(Percent of Glass will vary on specific products depending on sitelines)
(Based on single bay of Curtain Wall/Window Wall)
2
Example Glass U-factor
= 0.48 Btu/(ft · h ·°F)
Vision Area
= 5(9 + 8 + 4) = 105.0 ft 2
Total Area (Vision)
= 5' 2-1/2"( 9' 3-3/4"+ 8' 2-1/2" + 4' 2-1/2") = 113.2 ft
Percent of Vision Glass
= (Vision Area ÷ Total Area)100
= (105.0 ÷ 113.2)100 = 93%
Spandrel Area
kawneer,com
2
Example Spandrel R-value
= 15 (ft · h · °F)/Btu
Spandrel Area
= 5(6 + 3) = 45.0 ft
Total Area (Spandrel)
= 5' 2-1/2"(6' 2-1/2" + 3' 3-3/4") = 49.6 ft 2
Percent of Spandrel
= (Spandrel Area ÷ Total Area)100
= (45.0 ÷ 49.6)100 = 91%
2
ADMD030EN
2
17
1600 WALL SYSTEMTM3
JULY, 2014
THERMAL CHARTS
EC 97911-063
Vision Area Chart
System U-factor vs Percent of Vision Area
E
L n)
P sig
M e
A rD
X fo
E ot
(N
2
Ih·ft· °F
System U-factor
0.53
0.50
Btu
0.60
2
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
0.70
Btu
COG
U-factor
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
0.80
0.40
0.30
0.20
95
93%
90
85
80
75
70
Vision Area / Total Area (%)
System U-factor vs Percent of Spandrel Area
Spandrel
R-value
0.60
E
L n)
P sig
M e
A rD
X fo
E ot
(N
3.00
4.00
5.00
11.00
15.00
19.00
30.00
95
0.50
0.40
0.30
Ih·ft· °F
System U-factor
2.00
0.21
0.20
0.10
90
85
80
75
70
Spandrel Area / Total Area (%)
Based on a single curtain wall bay of 91% spandrel and center of
2
spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft ·°F)
ADMD030EN
kawneer,com
© Kawneer Company, Inc,, 2014
Spandrel Area Chart
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
Based on a single curtain wall bay of 93% vision glass and center
2
of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft ·°F)
91%
18
1600 WALL SYSTEMTM3
JULY, 2014
EC 97911-063
19
THERMAL CHARTS
Note:
Values in parentheses are metric.
COG = Center Of Glass.
Charts are generated per AAMA 507.
System U-Factors for Vision Glass
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
0.80
(4.50)
0.75
0.70
(4.00)
0.65
0.60
System U-factor
0.45
(3.00)
System U-factor
0.50
W
2
m ·°C
0.55
(2.73)
(2.61)
(2.50)
(2.39)
(2.27)
(2.16)
(2.05)
(1.93)
(1.82)
(1.71)
(1.59)
(1.48)
(1.37)
(1.25)
(1.14)
W
2
m ·°C
0.48
0.46
0.44
0.42
0.40
0.38
0.36
0.34
0.32
0.30
0.28
0.26
0.24
0.22
0.20
(3.50)
Btu
2
h·ft ·°F
COG
U-factor
(2.50)
0.40
0.35
(2.00)
0.30
(1.50)
0.25
0.20
95
90
85
80
75
70
Vision Area / Total Area (%)
0.70
(4.00)
0.65
0.60
(3.50)
0.55
(3.00)
0.50
0.45
0.40
2.00 (0.35)
0.35
3.00 (0.53)
(2.50)
Btu
2
h·ft ·°F
Spandrel
R-Value
© Kawneer Company, Inc,, 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
System U-Factors for Spandrel Glass
(2.00)
0.30
4.00 (0.70)
0.25
5.00 (0.88)
(1.50)
0.20
(2.00)
0.15
11.00 (1.94)
15.00 (2.64)
0.10
19.00 (3.34)
30.00 (5.28)
95
0.05
90
85
80
Spandrel Area / Total Area (%)
kawneer,com
ADMD030EN
75
70
(1.50)
1600 WALL SYSTEMTM3
JULY, 2014
THERMAL CHARTS
COG
SHGC
EC 97911-063
System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area
0.90
0.90
0.85
0.85
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
0.80
0.80
0.75
0.75
0.70
0.70
0.60
0.60
0.55
0.55
0.50
0.50
0.45
0.45
0.40
0.40
0.35
0.35
0.30
0.30
0.25
0.25
0.20
0.20
System SHGC
0.65
0.65
0.15
0.10
95
90
85
80
75
70
Vision Area / Total Area (%)
Charts are generated per AAMA 507.
0.85
0.85
0.80
0.80
0.75
0.75
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
0.90
0.90
0.70
0.70
0.65
0.65
0.60
0.60
0.55
0.55
0.50
0.50
0.45
0.45
0.40
0.40
0.35
0.35
0.30
0.30
0.25
0.25
0.20
0.20
0.15
0.10
95
90
85
80
75
70
Vision Area / Total Area (%)
Charts are generated per AAMA 507.
ADMD030EN
kawneer,com
© Kawneer Company, Inc,, 2014
System Visible Transmittance (VT) vs Percent of Vision Area
COG
VT
System VT
20
1600 WALL SYSTEMTM3
JULY, 2014
EC 97911-063
21
THERMAL PERFORMANCE MATRIX (NFRC SIZE)
Thermal Transmittance 1 (BTU/hr • ft 2 • °F)
Overall U-Factor 4
0.48
0.56
0.46
0.55
0.44
0.53
0.42
0.51
0.40
0.49
0.38
0.48
0.36
0.46
0.34
0.44
0.32
0.43
0.30
0.41
0.28
0.39
0.26
0.37
0.24
0.36
0.22
0.34
0.20
0.32
NOTE:For glass values that are not listed, linear
interpolation is permitted.
1.
2.
3.
4.
SHGC Matrix 2
© Kawneer Company, Inc,, 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
Glass U-Factor 3
kawneer,com
U-Factors are determined in accordance with NFRC 100.
SHGC and VT values are determined in accordance with
NFRC 200.
Glass properties are based on center of glass values and
are obtained from your glass supplier.
Overall U-Factor, SHGC, and VT Matricies are based on
the standard NFRC specimen size of 2000mm wide by
2000mm high (78-3/4" by 78-3/4").
Visible Transmittance 2
Glass SHGC 3
Overall SHGC 4
Glass VT 3
Overall VT 4
0.75
0.69
0.90
0.81
0.70
0.65
0.85
0.76
0.65
0.60
0.80
0.72
0.60
0.56
0.75
0.67
0.55
0.51
0.70
0.63
0.50
0.47
0.65
0.58
0.45
0.43
0.60
0.54
0.40
0.38
0.55
0.49
0.35
0.34
0.50
0.45
0.30
0.29
0.45
0.40
0.25
0.25
0.40
0.36
0.20
0.20
0.35
0.31
0.15
0.16
0.30
0.27
0.10
0.11
0.25
0.22
0.05
0.07
0.20
0.18
ADMD030EN
Laws and building and safety codes governing the design and use of glazed
entrance, window, and curtain wall products vary widely, Kawneer does not control
the selection of product configurations, operating hardware, or glazing materials,
and assumes no responsibility therefor,
1600 WALL SYSTEMTM3
BLANK PAGE
ADMD030EN
kawneer,com
© Kawneer Company, Inc,, 2014
Kawneer reserves the right to change configuration without prior notice when deemed
necessary for product improvement,
22
JULY, 2014
EC 97911-063