1600 WALL SYSTEMTM3 JULY, 2014 EC 97911-063 FEATURES Features • 1600 Wall SystemTM3 has a 2-1/2" (63.5) sight line • Standard 6" (152.4) or 7-1/2" (190.5) depth systems are compatible with SystemTM1 and SystemTM2 • Inside glazed verticals utilize the IsoStrutTM thermal barrier to provide superior structural and thermal performance • Integral vertical exterior cover and thermal barrier reduce installed cost • Horizontals utilize a thermal separator and pressure plate to allow for glazing or re-glazing from the exterior • Standard infill options are 1/8" (3.2), 1/4" (6.4) and 1" (25.4) • Thermally Broken by means of a continuous 1/4" (6.4) low conductance spacer • Concealed fastener joinery creates smooth, monolithic appearance • Shear block fabrication method • Standard 90 and 135 degree inside and outside corners available • Offers integrated entrance framing systems • Peroxide-cure high performance EPDM silicone compatible glazing materials for long-lasting seals • Two color option •PermanodicTM anodized finishes in seven choices • Painted finishes in standard and custom choices Optional Features • Steel reinforcing available • Integrates with Kawneer windows and concealed GLASSventTM for curtain wall • 1600 PowerWallTM solar photovoltaic (PV) infill in lieu of glass © Kawneer Company, Inc,, 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, • 1600 Wall SystemTM3 is an inside / outside glazed captured curtain wall Product Applications • Ideal for low-rise to high-rise curtain wall applications where inside glazing and high performance is desired For specific product applications, Consult your Kawneer representative. kawneer,com ADMD030EN 1 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, 1600 WALL SYSTEMTM3 BLANK PAGE ADMD030EN kawneer,com © Kawneer Company, Inc,, 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, 2 JULY, 2014 EC 97911-063 1600 WALL SYSTEMTM3 JULY, 2014 EC 97911-063 3 INDEX PICTORIAL VIEW..................................................................................... 5 TYPICAL 1/4 SIZE DETAILS................................................................. 6-7 ENTRANCE ADAPTERS.......................................................................... 8 CORNERS................................................................................................. 8 ANCHORING............................................................................................ 9 WIND LOAD CHARTS....................................................................... 10-13 DEADLOAD CHARTS....................................................................... 14-16 THERMAL CHARTS.......................................................................... 17-21 LAWS AND BUILDING AND SAFETY CODES GOVERNING THE DESIGN AND USE OF GLAZED ENTRANCE, WINDOW, AND CURTAIN WALL PRODUCTS VARY WIDELY. KAWNEER DOES NOT CONTROL THE SELECTION OF PRODUCT CONFIGURATIONS, OPERATING HARDWARE, OR GLAZING MATERIALS, AND ASSUMES NO RESPONSIBILITY THEREFOR. Metric (SI) conversion figures are included throughout these details for reference. Numbers in parentheses ( ) are millimeters unless otherwise noted. The following metric (SI) units are found in these details: m –meter cm – centimeter mm –millimeter s –second Pa –pascal MPa –megapascal © Kawneer Company, Inc,, 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, Architects – Most extrusion and window types illustrated in this catalog are standard products for Kawneer. These concepts have been expanded and modified to afford you design freedom. Some miscellaneous details are non-standard and are intended to demonstrate how the system can be modified to expand design flexibility. Please contact your Kawneer representative for further assistance. Kawneer reserves the right to change configurations without prior notice when deemed necessary for product improvement. kawneer,com ADMD030EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, 1600 WALL SYSTEMTM3 BLANK PAGE ADMD030EN kawneer,com © Kawneer Company, Inc,, 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, 4 JULY, 2014 EC 97911-063 © Kawneer Company, Inc,, 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, JULY, 2014 kawneer,com 1600 WALL SYSTEMTM3 EC 97911-063 PICTORIAL VIEW ADMD030EN 5 2 3 7 13 7A 13A 4 9 8 12 10 ELEVATION IS NUMBER KEYED TO DETAILS 13 11 ADMD030EN 7 1 7A 2 OPTIONAL HORIZONTAL 5 13A 11 6 3 12 10 NOTE: 6" SYSTEM SHOWN, 7-1/2" SIMILAR. INSIDE GLAZED IsoStrutTM VERTICALS SHOWN. 8 4 ALTERNATE JAMB 5 9 6 kawneer,com © Kawneer Company, Inc,, 2014 TYPICAL 1/4 SIZE DETAILS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, 1600 WALL SYSTEMTM3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, 6 JULY, 2014 EC 97911-063 SCALE 3" = 1'-0" 1 © Kawneer Company, Inc,, 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, JULY, 2014 7 14 13 13 kawneer,com 1600 WALL SYSTEMTM3 EC 97911-063 2 7A 4 12 10 6 ELEVATION IS NUMBER KEYED TO DETAILS 14 12 11 ADMD030EN 7 TYPICAL1/4 SIZE DETAILS SCALE 3" = 1'-0" 1 3 9 8 7 1 7A 2 OPTIONAL HORIZONTAL 5 11 3 10 NOTES: 6" SYSTEM SHOWN, 7-1/2" SIMILAR. APPLIED PRESSURE PLATE OPTION SHOWN. 8 4 5 9 6 2 3 1 2 1 1 OUTSIDE 90° CORNER OUTSIDE 135° CORNER ADMD030EN 3 ELEVATION IS NUMBER KEYED TO DETAILS NOTE: OFFSET PIVOT/BUTT HUNG ENTRANCE SHOWN. ALSO AVAILABLE FOR CENTER HUNG 7/8" (22.2) INSIDE 90° CORNER INSIDE 135° CORNER kawneer,com © Kawneer Company, Inc,, 2014 ENTRANCE ADAPTERS / CORNERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, 1600 WALL SYSTEMTM3 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, 8 JULY, 2014 EC 97911-063 SCALE 3" = 1'-0" ENTRANCE ADAPTERS 2 CORNERS © Kawneer Company, Inc,, 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, JULY, 2014 kawneer,com 1600 WALL SYSTEMTM3 EC 97911-063 ANCHORING ADMD030EN 9 10 1600 WALL SYSTEMTM3 JULY, 2014 WIND LOAD CHARTS EC 97911-063 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. (960 Pa) (1440 Pa) (1920 Pa) (2400 Pa) (2880 Pa) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, A = 20 PSF B = 30 PSF C = 40 PSF D = 50 PSF E = 60 PSF SINGLE SPAN WIDTH IN METERS .5 1 1.5 2 15 14 A 11 B 10 3 C D 2.5 9 8 E 7 2 6 5 1.5 3 4 5 6 WIDTH IN FEET 7 8 SINGLE SPAN WIDTH IN METERS .5 1 1.5 2 15 A 14 3.5 11 C 10 D3 9 E 2.5 8 7 2 6 5 4 MULLION HEIGHT HEIGHT IN FEET B 12 HEIGHT IN METERS 4 13 1.5 1 2 3 4 5 6 7 163201 8 WIDTH IN FEET ADMD030EN kawneer,com © Kawneer Company, Inc,, 2014 2 1 163200 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, 4 3.5 MULLION HEIGHT HEIGHT IN FEET 12 HEIGHT IN METERS 4 13 1600 WALL SYSTEMTM3 JULY, 2014 EC 97911-063 11 WIND LOAD CHARTS Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, A = 20 PSF B = 30 PSF C = 40 PSF D = 50 PSF E = 60 PSF SINGLE SPAN WIDTH IN METERS .5 1 1.5 2 15 14 3.5 11 A 10 B 9 C 2.5 D E 2 8 6 5 4 3 MULLION HEIGHT HEIGHT IN FEET 12 HEIGHT IN METERS 4 13 7 163204 1.5 2 1 3 4 5 6 WIDTH IN FEET 7 8 SINGLE SPAN WIDTH IN METERS .5 1 1.5 2 15 HEIGHT IN FEET 12 B 3.5 11 C 10 D 9 3 E 2.5 8 7 2 6 5 4 4 1.5 1 2 3 4 5 6 7 8 WIDTH IN FEET kawneer,com MULLION HEIGHT A 13 HEIGHT IN METERS 14 © Kawneer Company, Inc,, 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, (960 Pa) (1440 Pa) (1920 Pa) (2400 Pa) (2880 Pa) ADMD030EN 163205 12 1600 WALL SYSTEMTM3 JULY, 2014 WIND LOAD CHARTS EC 97911-063 Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. (960 Pa) (1440 Pa) (1920 Pa) (2400 Pa) (2880 Pa) Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, A = 20 PSF B = 30 PSF C = 40 PSF D = 50 PSF E = 60 PSF SINGLE SPAN WIDTH IN METERS .5 1 1.5 2 15 12 A 11 10 B 9 C 8 D E 7 6 5 4 3.5 3 2.5 MULLION HEIGHT 4 13 HEIGHT IN METERS HEIGHT IN METERS 14 2 163208 1.5 1 2 3 4 5 6 7 8 SINGLE SPAN WIDTH IN METERS .5 1 1.5 2 15 14 A B 11 10 D 9 E 8 7 3 2.5 2 6 5 4 3.5 C MULLION HEIGHT HEIGHT IN FEET 12 HEIGHT IN METERS 4 13 1.5 1 2 3 4 5 6 WIDTH IN FEET 7 163209 8 ADMD030EN kawneer,com © Kawneer Company, Inc,, 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, WIDTH IN FEET 1600 WALL SYSTEMTM3 JULY, 2014 EC 97911-063 13 WIND LOAD CHARTS SINGLE SPAN TWIN SPAN WIDTH IN METERS WIDTH IN METERS 1.5 2 .5 4.4 14 12 3.3 11 10 A 9 3 6 B 2.2 C D 2 E 5 1.5 8 7 HEIGHT IN METERS 4 13 25 7.5 24 23 7 A 22 6.5 21 20 6 19 B 5.5 17 5 .5 163038 0 2 1 3 4 5 6 7 8 A = 20 PSF B = 30 PSF C = 40 PSF D = 50 PSF E = 60 PSF WIDTH IN METERS 1 1.5 4.5 14 D 13 E 12 SINGLE SPAN .5 C 15 WIDTH IN FEET (960 Pa) (1440 Pa) (1920 Pa) (2400 Pa) (2880 Pa) 0 2 1 3 .5 17 29 12 3.3 11 B 10 C 9 D 8 E 7 3 2.2 2 6 5 6 7 1 1.5 9 A 27 25 7.5 24 23 B 22 20 C 19 2 5.5 5 E 15 4.5 14 .5 1 4 13 0 1 2 3 4 5 6 7 8 6 D 16 1 7 6.5 21 17 1.5 8.5 8 26 18 4 3 8 2 28 HEIGHT IN FEET A HEIGHT IN METERS 4 13 MULLION HEIGHT 4.4 14 MULLION HEIGHT EQUAL EQUAL 30 15 5 WIDTH IN METERS 18 5 4 WIDTH IN FEET 4 TWIN SPAN 2 16 HEIGHT IN FEET 8 26 18 1 © Kawneer Company, Inc,, 2014 8.5 27 1 2 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, 9 16 3 163039 WIDTH IN FEET kawneer,com 2 28 4 0 1.5 29 HEIGHT IN FEET 15 MULLION HEIGHT EQUAL EQUAL 5 16 MULLION HEIGHT 17 0 1 30 12 0 1 2 3 4 5 6 WIDTH IN FEET ADMD030EN HEIGHT IN METERS 1 7 8 HEIGHT IN METERS .5 18 HEIGHT IN FEET Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, Mullions are designed for deflection limitations in accordance with AAMA TIR-A11 of L/175 up to 13'-6" and L/240 +1/4" above 13'-6". These curves are for mullions WITH HORIZONTALS and are based on engineering calculations for stress and deflection. Allowable wind load stress for ALUMINUM 15,152 psi (104MPa), STEEL 30,000 psi (207MPa.). Charted curves, in all cases are for the limiting value. If the design wind load is determined through the analytical procedures of ASCE/SEI 7-10 or earlier editions, the load shall be based on the nominal loads used in allowable stress design. A 4/3 increase in allowable stress has not been used to develop these curves. For special situations not covered by these curves, contact your Kawneer representative for additional information. 1600 WALL SYSTEMTM3 14 JULY, 2014 DEADLOAD CHARTS EC 97911-063 Horizontal or deadload limitations are based upon 1/8" maximum deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" and 1" thick glass supported on two setting blocks placed at the loading points shown. 1/4" GLASS 1" GLASS WIDTH IN METERS WIDTH IN METERS 1 1.5 2 12 1.5 2 10 B 5 1.5 4 A 3 163004 1 2 0 2 1 7 6 5 B 5 1.5 A 4 1 0.5 1 0 8 0 0 WIDTH IN FEET 2 1 4 3 7 6 5 1/4" GLASS 1" GLASS WIDTH IN METERS 1 1.5 2 .5 13 12 8 WIDTH IN FEET WIDTH IN METERS .5 13 4 3 2 6 2 0 0 2.5 8 7 3 0.5 1 3 9 1 1.5 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, 2 6 HEIGHT IN FEET 2.5 8 7 HEIGHT IN METERS 3 9 3.5 11 HEIGHT IN METERS 10 2 12 3.5 11 10 10 7 2 B 6 5 1.5 A 4 163005 1 3 2 3 9 2.5 8 7 2 B 6 5 1.5 A 4 1 3 2 0.5 1 HEIGHT IN FEET 2.5 8 HEIGHT IN METERS 3 9 3.5 11 0.5 1 0 0 0 0 1 2 3 4 5 6 7 8 0 0 WIDTH IN FEET ADMD030EN HEIGHT IN METERS HEIGHT IN FEET 1 12 3.5 11 HEIGHT IN FEET .5 13 1 2 3 4 5 6 7 8 WIDTH IN FEET kawneer,com © Kawneer Company, Inc,, 2014 .5 13 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, A = 1/4 POINT LOADING B = 1/8 POINT LOADING 1600 WALL SYSTEMTM3 JULY, 2014 EC 97911-063 15 DEADLOAD CHARTS Horizontal or deadload limitations are based upon 1/8" maximum deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" and 1" thick glass supported on two setting blocks placed at the loading points shown. 1/4" GLASS 1" GLASS WIDTH IN METERS WIDTH IN METERS .5 13 1 1.5 2 12 A 2 6 5 1.5 4 163010 163004 1 2 1 7 6 5 WIDTH IN FEET A 6 5 1.5 4 1 0.5 1 0 8 0 0 1 2 4 3 5 7 6 1" GLASS WIDTH IN METERS 1.5 2 .5 13 12 8 WIDTH IN FEET 1/4" GLASS 1 2 B WIDTH IN METERS .5 13 4 3 2.5 8 7 2 0 0 3 9 3 0.5 0 3.5 HEIGHT IN METERS 2.5 8 7 HEIGHT IN FEET 9 2 1 1.5 2 12 3.5 3 9 A 8 2.5 B 7 2 6 5 1.5 4 10 163010 163005 1 3 2 0 1 2 3 4 5 6 WIDTH IN FEET 7 A 8 2.5 7 B 6 2 5 1.5 4 1 2 0.5 1 0 0 0 3 9 3 0.5 1 HEIGHT IN FEET 10 3.5 11 HEIGHT IN METERS 11 HEIGHT IN FEET 2 10 3 B 3 © Kawneer Company, Inc,, 2014 1.5 11 HEIGHT IN METERS HEIGHT IN FEET 10 1 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, 1 12 3.5 11 kawneer,com .5 13 8 0 0 ADMD030EN 1 2 3 4 5 6 WIDTH IN FEET 7 8 HEIGHT IN METERS Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, A = 1/4 POINT LOADING B = 1/8 POINT LOADING 1600 WALL SYSTEMTM3 16 JULY, 2014 DEADLOAD CHARTS EC 97911-063 Horizontal or deadload limitations are based upon 1/8" maximum deflection at the center of an intermediate horizontal member. The accompanying charts are calculated for 1/4" and 1" thick glass supported on two setting blocks placed at the loading points shown. 1/4" GLASS 1" GLASS WIDTH IN METERS WIDTH IN METERS 1 1.5 2 12 1.5 2 7 2 A 6 5 1.5 4 163025 2 0 2 1 5 7 6 WIDTH IN FEET 1.5 1 0.5 1 0 8 0 0 2 1 3 4 7 6 5 1/4" GLASS 1" GLASS WIDTH IN METERS 1 1.5 2 .5 13 1 1.5 2 12 3.5 11 10 10 A 2 6 5 1.5 4 163026 1 3 2 0 1 2 3 4 5 6 7 2.5 8 7 2 A 6 5 1.5 4 1 2 0.5 1 0 0 0 3 B 9 3 0.5 1 HEIGHT IN FEET 2.5 8 7 HEIGHT IN METERS 3 9 3.5 11 B 8 0 0 WIDTH IN FEET ADMD030EN HEIGHT IN METERS 12 8 WIDTH IN FEET WIDTH IN METERS .5 13 4 3 A 5 2 0 0 2 6 3 0.5 1 2.5 7 4 1 3 B 8 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, 2.5 8 3 9 HEIGHT IN METERS 9 10 HEIGHT IN FEET 3 B 3.5 11 HEIGHT IN METERS 10 HEIGHT IN FEET 1 12 3.5 11 HEIGHT IN FEET .5 13 1 2 3 4 5 6 WIDTH IN FEET 7 8 kawneer,com © Kawneer Company, Inc,, 2014 .5 13 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, A = 1/4 POINT LOADING B = 1/8 POINT LOADING 1600 WALL SYSTEMTM3 JULY, 2014 EC 97911-063 THERMAL CHARTS VISION 2-1/2" Typ. 3'-0" D.L.O. 4'-0" D.L.O. VISION 6'-0" D.L.O. SPANDREL 9'-0" D.L.O. 31'-3" SPANDREL 8'-0" D.L.O. 2-1/2" Typ. VISION 5'-0" D.L.O. Vision Area © Kawneer Company, Inc,, 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, Generic Project Specific U-factor Example Calculation (Percent of Glass will vary on specific products depending on sitelines) (Based on single bay of Curtain Wall/Window Wall) 2 Example Glass U-factor = 0.48 Btu/(ft · h ·°F) Vision Area = 5(9 + 8 + 4) = 105.0 ft 2 Total Area (Vision) = 5' 2-1/2"( 9' 3-3/4"+ 8' 2-1/2" + 4' 2-1/2") = 113.2 ft Percent of Vision Glass = (Vision Area ÷ Total Area)100 = (105.0 ÷ 113.2)100 = 93% Spandrel Area kawneer,com 2 Example Spandrel R-value = 15 (ft · h · °F)/Btu Spandrel Area = 5(6 + 3) = 45.0 ft Total Area (Spandrel) = 5' 2-1/2"(6' 2-1/2" + 3' 3-3/4") = 49.6 ft 2 Percent of Spandrel = (Spandrel Area ÷ Total Area)100 = (45.0 ÷ 49.6)100 = 91% 2 ADMD030EN 2 17 1600 WALL SYSTEMTM3 JULY, 2014 THERMAL CHARTS EC 97911-063 Vision Area Chart System U-factor vs Percent of Vision Area E L n) P sig M e A rD X fo E ot (N 2 Ih·ft· °F System U-factor 0.53 0.50 Btu 0.60 2 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 0.70 Btu COG U-factor Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, 0.80 0.40 0.30 0.20 95 93% 90 85 80 75 70 Vision Area / Total Area (%) System U-factor vs Percent of Spandrel Area Spandrel R-value 0.60 E L n) P sig M e A rD X fo E ot (N 3.00 4.00 5.00 11.00 15.00 19.00 30.00 95 0.50 0.40 0.30 Ih·ft· °F System U-factor 2.00 0.21 0.20 0.10 90 85 80 75 70 Spandrel Area / Total Area (%) Based on a single curtain wall bay of 91% spandrel and center of 2 spandrel R-value of 15, system U-factor is equal to 0.21 Btu/(h·ft ·°F) ADMD030EN kawneer,com © Kawneer Company, Inc,, 2014 Spandrel Area Chart Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, Based on a single curtain wall bay of 93% vision glass and center 2 of glass U-factor of 0.48, System U-factor is equal to 0.53 Btu/(h·ft ·°F) 91% 18 1600 WALL SYSTEMTM3 JULY, 2014 EC 97911-063 19 THERMAL CHARTS Note: Values in parentheses are metric. COG = Center Of Glass. Charts are generated per AAMA 507. System U-Factors for Vision Glass Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, 0.80 (4.50) 0.75 0.70 (4.00) 0.65 0.60 System U-factor 0.45 (3.00) System U-factor 0.50 W 2 m ·°C 0.55 (2.73) (2.61) (2.50) (2.39) (2.27) (2.16) (2.05) (1.93) (1.82) (1.71) (1.59) (1.48) (1.37) (1.25) (1.14) W 2 m ·°C 0.48 0.46 0.44 0.42 0.40 0.38 0.36 0.34 0.32 0.30 0.28 0.26 0.24 0.22 0.20 (3.50) Btu 2 h·ft ·°F COG U-factor (2.50) 0.40 0.35 (2.00) 0.30 (1.50) 0.25 0.20 95 90 85 80 75 70 Vision Area / Total Area (%) 0.70 (4.00) 0.65 0.60 (3.50) 0.55 (3.00) 0.50 0.45 0.40 2.00 (0.35) 0.35 3.00 (0.53) (2.50) Btu 2 h·ft ·°F Spandrel R-Value © Kawneer Company, Inc,, 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, System U-Factors for Spandrel Glass (2.00) 0.30 4.00 (0.70) 0.25 5.00 (0.88) (1.50) 0.20 (2.00) 0.15 11.00 (1.94) 15.00 (2.64) 0.10 19.00 (3.34) 30.00 (5.28) 95 0.05 90 85 80 Spandrel Area / Total Area (%) kawneer,com ADMD030EN 75 70 (1.50) 1600 WALL SYSTEMTM3 JULY, 2014 THERMAL CHARTS COG SHGC EC 97911-063 System Solar Heat Gain Coefficient (SHGC) vs Percent of Vision Area 0.90 0.90 0.85 0.85 Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, 0.80 0.80 0.75 0.75 0.70 0.70 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 System SHGC 0.65 0.65 0.15 0.10 95 90 85 80 75 70 Vision Area / Total Area (%) Charts are generated per AAMA 507. 0.85 0.85 0.80 0.80 0.75 0.75 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, 0.90 0.90 0.70 0.70 0.65 0.65 0.60 0.60 0.55 0.55 0.50 0.50 0.45 0.45 0.40 0.40 0.35 0.35 0.30 0.30 0.25 0.25 0.20 0.20 0.15 0.10 95 90 85 80 75 70 Vision Area / Total Area (%) Charts are generated per AAMA 507. ADMD030EN kawneer,com © Kawneer Company, Inc,, 2014 System Visible Transmittance (VT) vs Percent of Vision Area COG VT System VT 20 1600 WALL SYSTEMTM3 JULY, 2014 EC 97911-063 21 THERMAL PERFORMANCE MATRIX (NFRC SIZE) Thermal Transmittance 1 (BTU/hr • ft 2 • °F) Overall U-Factor 4 0.48 0.56 0.46 0.55 0.44 0.53 0.42 0.51 0.40 0.49 0.38 0.48 0.36 0.46 0.34 0.44 0.32 0.43 0.30 0.41 0.28 0.39 0.26 0.37 0.24 0.36 0.22 0.34 0.20 0.32 NOTE:For glass values that are not listed, linear interpolation is permitted. 1. 2. 3. 4. SHGC Matrix 2 © Kawneer Company, Inc,, 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, Glass U-Factor 3 kawneer,com U-Factors are determined in accordance with NFRC 100. SHGC and VT values are determined in accordance with NFRC 200. Glass properties are based on center of glass values and are obtained from your glass supplier. Overall U-Factor, SHGC, and VT Matricies are based on the standard NFRC specimen size of 2000mm wide by 2000mm high (78-3/4" by 78-3/4"). Visible Transmittance 2 Glass SHGC 3 Overall SHGC 4 Glass VT 3 Overall VT 4 0.75 0.69 0.90 0.81 0.70 0.65 0.85 0.76 0.65 0.60 0.80 0.72 0.60 0.56 0.75 0.67 0.55 0.51 0.70 0.63 0.50 0.47 0.65 0.58 0.45 0.43 0.60 0.54 0.40 0.38 0.55 0.49 0.35 0.34 0.50 0.45 0.30 0.29 0.45 0.40 0.25 0.25 0.40 0.36 0.20 0.20 0.35 0.31 0.15 0.16 0.30 0.27 0.10 0.11 0.25 0.22 0.05 0.07 0.20 0.18 ADMD030EN Laws and building and safety codes governing the design and use of glazed entrance, window, and curtain wall products vary widely, Kawneer does not control the selection of product configurations, operating hardware, or glazing materials, and assumes no responsibility therefor, 1600 WALL SYSTEMTM3 BLANK PAGE ADMD030EN kawneer,com © Kawneer Company, Inc,, 2014 Kawneer reserves the right to change configuration without prior notice when deemed necessary for product improvement, 22 JULY, 2014 EC 97911-063