IVO RXA1H.2204101

Absolute encoders - parallel
Hollow shaft ø14 mm
Singleturn encoder 13 bit, 1024 cams
RXA1H
Features
–– Encoder multiturn / parallel
–– Optical sensing
–– Resolution: 13 bit
–– Hollow shaft ø14 mm
–– Integrated programmable cams unit
–– Dead time compensation, rotation speed control
–– Encoder programming by Windows software
–– RS232 encoder programming interface
–– 16 outputs with 1024 cams
–– High-side performance driver 1.5 A
Technical data - mechanical design
Voltage supply
Housing
ø75 mm
Reverse polarity protection Yes
10...30 VDC
Shaft
ø14 mm hollow shaft
Consumption w/o load
≤50 mA (24 VDC)
Protection DIN EN 60529
IP 54
Initializing time (typ.)
250 ms after power on
Operating speed
Interface
Parallel (cams)
≤6000 rpm (mechanical)
≤6000 rpm (electric)
Number of cams
1024
Rotor moment of inertia
20 gcm²
Steps per turn
8192 / 13 bit
Materials
Absolute accuracy
±0.025°
Housing: steel
Flange: aluminium
Sensing method
Optical
Operating temperature
Code
Binary
-25...+85 °C
-40...+85 °C (optional)
Code sequence
CW default, programmable
Relative humidity
95 % non-condensing
Inputs
TxD, RxD (RS232)
Control signals start and zero
Program selection 1-16
Resistance
DIN EN 60068-2-6
Vibration 10 g, 16-2000 Hz
DIN EN 60068-2-27
Shock 200 g, 6 ms
Output circuit
Highside performance driver
with 2 x 1.5 A
Weight approx.
700 g
E-connection
Connector D-SUB, 37‑pin, 1 m
cable
Interference immunity
DIN EN 61000-6-2
Emitted interference
DIN EN 61000-6-4
Programming interface
RS232
Programmable
parameters
Steps per revolution
Rotational direction CW/CCW
Cams program
Rotation speed monitoring
Diagnostic functions
Self-diagnosis
Code continuity check
Status indicator
DUO-LED integrated in bus
cover
1
www.baumerivo.com
29/10/2008
Technical data - electrical ratings
Subject to modification in technic and design. Errors and omissions excepted.
RXA1H with hollow shaft
Absolute encoders - parallel
Hollow shaft ø14 mm
Singleturn encoder 13 bit, 1024 cams
RXA1H
Accessories
Part number
2
20
41
Connectors and cables (page %S)
01
Z 140.001
E-connection
41 Cable 1 m radial, connector
D‑SUB, 37-pins
Female connector D-SUB, 37-pin
Mounting accessories (page %S)
Voltage supply / signals
20 12...30 VDC
Hollow shaft
2 Hollow shaft ø14 mm clamping ring
Z 119.037
Rubber buffer element 18.5 mm long, as
torque support
Z 119.039
Set of adjusting angles as torque support
Z 119.040
Shoulder screw M5 as torque support
Z 119.041
Torque support by rubber buffer element for
encoders with 15 mm pin
Z 119.043
Spring coupling for GX and G1
Programming accessories (page %S)
Programming cable for parallel encoders with
cams, CD with ProCam software and manual
Subject to modification in technic and design. Errors and omissions excepted.
Z 139.009
2
www.baumerivo.com
29/10/2008
RXA1H.
Absolute encoders - parallel
Hollow shaft ø14 mm
Singleturn encoder 13 bit, 1024 cams
RXA1H
Terminal significance
Terminal assignment
UB
Encoder voltage supply.
Connector
Core colour
Assignment
GND
Ground connection of encoder and output
drivers relating to UB.
Pin 1
white
Output 1
Pin 2
brown
Output 2
Zero setting
Input for setting a zero point anywhere
within the programmed encoder resolution.
The zero setting operation is released by a
High impulse and has to be in line with the
selected counting direction (UP/DOWN).
Connect to GND after reset operation for
maximum interference immunity. Impulse
duration >100 ms.
For safety reasons any reset operation will
immediately stop a running cams program.
Start
Programs
Program start input.
Applying a High potential (UB) for at least
100 ms will start the selected cams
program. If the start input is firmly connected to UB, the cams program selected
at the programming inputs will immediately
start after encoder power on.
Inputs for program selection 1-16.
Preset of the cams program in binary code.
Program 1 is selected by code 0-0-0-0
program 16 by 1-1-1-1.
Input „Program 1“: Valence „1“
Input „Program 2“: Valence „2“
Input „Program 4“: Valence „4“
Input „Program 8“: Valence „8“
After encoder power on and upon every
alteration at the programming inputs the
cams program selection by the four
programming inputs will be valid. A later
selection by serial programming interface
will overwrite the selection made at the four
programming inputs. Every alteration of the
program inputs will immediately stop a
running cams program.
VPOS1
VPOS2
Separate voltage supply of output driver
(outputs 1-8: pin 32, outputs 9-16: pin 33).
GND-PRG
Pin 3
green
Output 3
Pin 4
yellow
Output 4
Pin 5
grey
Output 5
Pin 6
pink
Output 6
Pin 7
black
Output 7
Pin 8
violet
Output 8
Pin 9
grey/pink
Output 9
Pin 10
red/blue
Output 10
Pin 11
white/green
Output 11
Pin 12
braun/green
Output 12
Pin 13
white/yellow
Output 13
Pin 14
yellow/brown Output 14
Pin 15
white/grey
Output 15
Pin 16
grey/brown
Output 16
Pin 17
yellow/blue
–
Pin 18
green/grey
–
Pin 19
yellow/pink
–
Pin 20
–
–
Pin 21
–
–
Pin 22
–
–
Pin 23
–
–
Pin 24
–
–
Pin 25
white/pink
Start
Pin 26
pink/brown
Zero setting
Pin 27
white/red
Program 1
Pin 28
brown/red
Program 2
Pin 29
white/black
Program 4
Pin 30
brown/black
Program 8
Pin 31
pink/green
GND-PRG
Pin 32
grey/green
VPOS1
Pin 33
yellow/grey
VPOS2
Separate ground of programming interface
RS232.
Pin 34
white/blue
TxD
Pin 35
brown/blue
RxD
RxD
Encoder receiver input for RS232 programming interface.
Pin 36
red
UB
TxD
Encoder transmitter output for RS232
programming interface.
Pin 37
blue
GND
3
Subject to modification in technic and design. Errors and omissions excepted.
16 programmable cams outputs.
Each output enables optionally alternative
configuration as special output.
www.baumerivo.com
29/10/2008
Outputs
1-16
Absolute encoders - parallel
Hollow shaft ø14 mm
Singleturn encoder 13 bit, 1024 cams
RXA1H
Terminal assignment programming cable
Trigger level
Encoder
function
D-SUB connector Core
37-pins
colour
PC connector
D-SUB, 9-pins
Control inputs
Input circuit
UB
Pin 36
brown
–
Input level High
>0.7 UB
RxD
Pin 35
beige
Pin 3
Input level Low
<0.3 UB
GND
Pin 37
Pin 37
black
blue
–
Pin 5
Input resistance
10 kΩ
TxD
Pin 34
green
Pin 2
Parallel outputs
Output circuit
High-Side linedriver
circuit-proof
Output level High
>UB -1 V (I = -500 mA)
Load High
<500 mA / Output
Load for each output
1-8 and 9-16 in sum
<1.5 A
Jumper 4-6 and
Jumper 7-8
Connect encoder to supply voltage (UB/red and GND/blue)
using the supplementary connections.
Dimensions
15
3.5
75
76
ø60
17.5
1
ø4fg6
ø30
ø14H7
3H11
56.5
50
6
19
M4 x 8
6.5
UNC-40
70
4
www.baumerivo.com
29/10/2008
Subject to modification in technic and design. Errors and omissions excepted.
LED