Datasheet

PowerPlus DC
• Optically Isolated MOSFET output
• Ratings from 10A to 60A @ 72 VDC
• AC control
• Relays are easily paralleled for higher-current applications
• LED Status Indicator
• Optional IP20 Cover
• UL Recognized, CE and RoHS Compliant
PRODUCT SELECTION
Control Voltage
10A
90-140 VAC
20A
40A
DC100A20
DC100A10
DC100A40
60A
DC100A60
AVAILABLE OPTIONS
Control Voltage
A: 90-140 VAC
Series
DC
100
A
Operating Voltage
100: 7-72 VDC
40
Cover
Blank: Not
Included
C: Included
C
Thermal Pad
Blank: Not Included
H: Included
H
Rated Load Current
10: 10 Amps
20: 20 Amps (Not valid with 400A suffix)
40: 40 Amps (Not valid with 400x suffixes)
60: 60 Amps (Not valid with 200A, 400x suffixes)
OUTPUT SPECIFICATIONS (1)
Description
Operating Voltage [Vdc] (2)
Blocking Voltage
Rated Load Current [Adc] (3)
Minimum Load Current [mA] (4)
Maximum Surge Current [Adc] (10ms)
Maximum On-State Voltage Drop @ Rated Current [Vdc]
Maximum Off-State Leakage Current @ Rated Voltage [mA]
Thermal Resistance Junction to Case (Rjc) [°C/W]
Maximum On-State Resistance @ Rated Current [RDS-ON][mOhms]
10A
1-72 VDC
100
10
2.5
66
0.32
0.15
1.44
32
20A
1-72 VDC
100
20
2.5
91
0.34
0.15
0.85
17
40A
1-72 VDC
100
40
2.5
136
0.6
0.15
0.78
15
60A
7-72 VDC
100
60
2.5
167
0.6
0.15
0.58
10
INPUT SPECIFICATIONS (1)
Description
Control Voltage Range
Minimum Input Current @ min Control Voltage [mA]
Maximum Input Current @ max Control Voltage [mA]
Nominal Input Impedance
Maximum Turn-On Time [msec]
Maximum Turn-Off Time [msec]
GENERAL SPECIFICATIONS
Description
Dielectric Strength, Input/Output/Base (50/60Hz)
Minimum Insulation Resistance (@ 500 V DC)
Maximum Capacitance, Input/Output
Ambient Operating Temperature Range (5)
Ambient Storage Temperature Range
Housing Material
Weight (typical) (6)
Encapsulation (7)
Terminal Finish
Recommended Terminal Screw Torque (6-32) [in lbs/Nm]
Recommended Terminal Screw Torque (8-32) [in lbs/Nm]
GENERAL NOTES
1) All parameters at 40°C and per section unless otherwise specified.
2) Maximum voltage is 100VDC
3) Heat sinking required, see derating curves.
4) Low current loads and high ambient temperature can affect turn-on time.
5) Maximum Ambient Operating Temperature for the AC control relays is 65°C.
6) Typical weight for the AC control relays is 2.99 oz/85g.
7) AC controlled relays contain thermal conductive epoxy.
.
MECHANICAL SPECIFICATIONS
DCxxxAxx
90-140 VAC
11
13
Current Regulated
10
10
Parameters
2500 Vrms
109 Ohm
10 pF
-30 to 80°C
-40 to 125 °C
Valox 420 SEO Black, UL 94 V-0
2.65 oz (75g)
Epoxy Free
Electroless Nickel
10/1.1
20/2.2
WIRING DIAGRAM
AGENCY APPROVALS
IEC 61000-4-2 Electrostatic Discharge
Level 3, Criteria A
IEC 61000-4-4 Electrically Fast Transients Level 3, Criteria A
IEC 61000-4-5 Electrical Surges
Level 3, Criteria A
E116950
072312
THERMAL DERATE INFORMATION
ANNEX - ENVIROMENTAL INFORMATION