Family data sheet

Product family datasheet
Low-voltage halogen lamps, road traffic
Areas of application
_ Road traffic signalling systems
__
Product benefits
_ Low-voltage halogen lamps, therefore particularly high luminous flux
_ Almost point-like light source for optimum focusing
_ Virtually constant luminous flux throughout the life of the lamp
_ Extremely long life compared to conventional lamps
June 13, 2016, 16:13:12
Low-voltage halogen lamps, road traffic
© 2016, OSRAM GmbH. All rights reserved.
Page 1 of 4
Product family datasheet
Product line drawing
Product line drawing
Product line drawing
__
June 13, 2016, 16:13:12
Low-voltage halogen lamps, road traffic
© 2016, OSRAM GmbH. All rights reserved.
Page 2 of 4
Product family datasheet
Technical data
Electrical data
Photomet
rical data
Dimensions & weight
Lifespan
Capabilities
Product description
Nominal
wattage
Nominal
voltage
Test voltage
Nominal
luminous
flux
Diameter
Overall length
Light
center
length
(LCL)
Nominal lamp
life time
Burning position
SIG 62165 1)
50.00 W
10.0 V
10 V
820 lm
11.5 mm
50.0 mm
26.0 mm 3)
2000 h
p90
4)
SIG 64016
50.00 W
12.0 V
12 V
900 lm
12.0 mm
44.0 mm
30.0 mm 3)
4000 h
p90
4)
5)
2000 h
p90
4)
SIG 64014
2)
SIG 64015
SIG 64012/1
50.00 W
10.0 V
10 V
950 lm
11.5 mm
42.0 mm
18.0 mm
50.00 W
10.0 V
10 V
750 lm
11.5 mm
42.0 mm
18.0 mm 5)
8000 h
p90
4)
31.0 mm
3)
2000 h
p90
4)
20.00 W
12.0 V
320 lm
9 mm
19.5 mm
Country specific
categorizations
__
Product description
SIG 62165
1)
SIG 64016
SIG 64014
Order reference
PA62165 CL 50W
SIG 64016 CL 50
2)
SIG 64014 CL 50
SIG 64015
SIG 64015 CL 50
SIG 64012/1
64012/1 CL 20W
1) Available on request
2) Particularly suitable for use in fiber-optic traffic signals
3) Distance from the coil to the top of base
4) Only the permissible burning position may be used otherwise the lamp will fail prematurely
5) Distance from the coil to the lug of base
June 13, 2016, 16:13:12
Low-voltage halogen lamps, road traffic
© 2016, OSRAM GmbH. All rights reserved.
Page 3 of 4
Product family datasheet
Operating instructions
All halogen signal lamps operate at high temperature and pressure. They may therefore only be operated in signal
equipment/luminaires specially designed for the purpose. Make sure that the lamps are protected against moisture during
operation and in particular during relamping. When installing a new lamp, handle it by its protective cardboard sleeve.
Application advice
For more detailed application information and graphics please see product datasheet.
Disclaimer
Subject to change without notice. Errors and omission excepted. Always make sure to use the most recent release.
__
June 13, 2016, 16:13:12
Low-voltage halogen lamps, road traffic
© 2016, OSRAM GmbH. All rights reserved.
Page 4 of 4