PDF cURus UL 60950-1, CSA 60950-1

File E123535
Project 01ME12890
October 15, 2001
REPORT
ON
COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT,
INCLUDING ELECTRICAL BUSINESS EQUIPMENT
Westcor, Div. Of Vicor Corp.
Sunnyvale, CA
Copyright © 2001 Underwriters Laboratories Inc.
Underwriters Laboratories Inc. authorizes the above-named company to
reproduce this Report provided it is reproduced in its entirety.
Underwriters Laboratories Inc. authorizes the above-named company to
reproduce that portion of this Report consisting of this Cover Page through
Page 2.
File E123535
Vol. 2
Sec. 9
and Report
Page 1
Issued:
Revised:
2001-10-15
2012-05-26
DESCRIPTION
PRODUCT COVERED:
USR, CNR Component AC-DC Switching Power Supplies, PFC Micro, and PFC
Micro-S Series, Model Pxa-bc-ddddd-e-ff.
Item 0. Series Type
x = S for Micro S
x = C for Micro
Input Voltage
115 Vac
230 Vac or 300 Vdc
Max Output Power
500 W
600 W
115 Vac
230 Vac or 300 Vdc
500 W
800 W
Item 1.
Number of Outputs
a = Total number of outputs (note: 3 for PC or 6 for PS), rated
0-95 Vdc each
Item 2.
Module Configuration
b = Total number of VI-200 and/or VI-J00 Series DC/DC Converters
c = Total number of 2nd Gen FasTrack Series DC/DC Converters
Item 3.
Factory assigned Code (Non-safty related)
ddddd = can be any alphanumeric combination or blanks
Item 4.
Configuration Revision (Optional)
e = can be any alphanumeric combination or blank (note: e = G for
RoHs compliant)
Item 5.
Micro description (Optional)
ff = can be any alphanumeric combination or blank
(note:MI for Mil COTs)
File E123535
Vol. 2
Sec. 9
and Report
Page 1A
Issued:
Revised:
2001-10-15
2012-05-26
GENERAL CHARACTER AND USE:
The PFC Micro Models are built using up to six Recognized Component
(QQGQ2) Vicor DC-DC switching power supplies, which provide reinforced
insulation between their inputs and outputs.
The PFC Micro Models Pxa-bc-ddddd-e-ff Power Supplies are an enclosed
assembly provided with an input connector and output connectors/terminals for
connection to a single-phase power source. Made for building in, and used
with Information Technology Equipment, Including Electrical business
equipment.
ELECTRICAL RATING:
Inputs:
115-230 V ac, 47-500 Hz, 7.5 A.
300 V dc, 7.5 A
Outputs:
Up to six rated 0-95 V dc.
OUTPUT POWER:
Using PFC Micro 500 Watts (100 V ac min input)
1-6 Outputs, 2 Slot
800 Watts (230 V ac)
Using PFC Micro-S - 500 Watts (100 V ac min input)
1-3 Outputs, 1 Slot
600 Watts (230 V ac)
File E123535
Vol. 2
Sec. 9
and Report
Page 2
Issued:
Revised:
2001-10-15
2012-05-26
ENGINEERING CONSIDERATIONS (NOT FOR UL REPRESENTATIVE USE):
USR/CNR indicates investigation to the U.S. and Canadian (Bi-National)
Standard for Safety of Information Technology Equipment, ANSI/UL60950-1-2011,
dated December 19, 2011 and CAN/CSA C22.2 No. 60950-1-07, 2nd Edition +
A1:2011 (MOD).
For use in (or with) complete equipment where the acceptability of the
combination is determined by Underwriters Laboratories Inc.
Conditions of Acceptability - When installed in the end-use equipment,
consideration shall be given to the following:
These components have been judged on the basis of the required spacings
in the Standard for Safety of Information Technology Equipment, CAN/CSA C22.2
No. 60950-1-07, 2nd Edition + A1:2011 (MOD)/ ANSI/UL60950-1-2011, dated
December 19, 2011, Sub. Clause 2.10, which would cover the component itself,
if submitted for Listing. Minimum spacings between live parts of opposite
polarity and between live and dead-metal parts shall be as indicated in
Tables 2M and 2N in UL/CSA 60950-1. Spacings (creepages and clearances) are
based on the provision of Basic Insulation.
1.
The power supply should be installed in compliance with the enclosure,
mounting, spacings, temperature, and casualty and segregation requirements of
the ultimate application.
*2.
The baseplate temperatures of the Vicor DC-DC converter switching power
supplies should be measured in the end-use equipment, and should not exceed
100°C.
3.
The acceptability of the input connector and output mating
connectors/terminals relative to secureness, insulating materials and
temperature should be considered in the end product evaluation.
4.
This product has been evaluated as Class I, Component Supply for
building-in.
5.
Secondary outputs 2V-48V comply with SELV requirements; higher voltage
outputs are non-SELV.
6.
Outputs above 240VA are considered hazardous energy.
7.
External fuse required. Bussman ABC-10 or a Littelfuse 505 Series
rated 10A, or a 10A Listed fuse.
File E123535
Vol. 2
Sec. 9
and Report
Page 3
Issued:
Revised:
2001-10-15
2007-03-26
CONSTRUCTION DETAILS:
Refer to Section General.
MODEL DIFFERENCES:
Both units are identical. They are different in the number of outputs,
the Module Complement and the total output power.
PFC Micro/2 Slot:(1-6 outputs)Each slot can accommodate the following:
2nd Gen FasTrak. 1 Maxi, or 2 Minis, or 3 Micro modules
or
1st Gen. 1 Full size(VI-200) or 2 Junior modules (VI-J00)
PFC Micro-S/1 Slot: (1-3 outputs) which can accommodate the following:
2nd Gen FasTrak. 1 Maxi, or 2 Minis, or 3 Micro modules
or
1st Gen. 1 Full size (VI-200) or 2 Junior modules (VI-J00)
MARKING
Optional marking for High leakage if frequency is above 60Hz on marking
plate. Marking to state the following or equivalent "HIGH LEAKAGE CURRENT Earth connection essential before connecting supply". Located adjacent to the
equipment primary power connection. See Section General for additional
marking.