File E123535 Project 03ME06490 2003-05-15 REPORT ON COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT, INCLUDING ELECTRICAL BUSINESS EQUIPMENT Westcor, Div. Of Vicor Corp. Sunnyvale, CA Copyright © 2003 Underwriters Laboratories Inc. Underwriters Laboratories Inc. authorizes the above-named company to reproduce this Report provided it is reproduced in its entirety. Underwriters Laboratories Inc. authorizes the above-named company to reproduce that portion of this Report consisting of this Cover Page through Page 2. File E123535 Vol. 2 Sec. 10 and Report Page 1 Issued: Revised: 2003-05-15 2007-04-02 DESCRIPTION PRODUCT COVERED: USR, CNR - Component AC-DC Switching Power Supplies, FlatPAC-EN Series, Model Fla-bc-dddddd-ee-xx. Item 0. Number of Outputs a = any number 0-4 (note: each output can be rated 0-95 V dc) Item 1. Module Configuration b = Total number of VI-200 and/or VI-J00 Series DC/DC Converters c = Total number of 2nd Gen Series DC/DC Converters. Item 2. Factory assigned Code (Non-safety related) dddddd = any alphanumeric combination or blanks Item 3. FlatPAC configuration Revision (Optional) ee = any alphanumeric combination or blanks (note: ee = G for RoHs compliant) Item 3. FlatPAC description (Optional) xx = Optional, any alphanumeric combination or blanks (note: xx = LL for low leakage models) (note: xx = E for extended temperature version) GENERAL CHARACTER AND USE: The FlatPAC-EN Models are built using up to four Recognized Component (QQGQ2) Vicor DC-DC switching power supplies, which provide reinforced insulation between their inputs and outputs. The FlatPAC-EN Model FLa-bc-dddddd-ee-xx Power Supplies are an enclosed assembly provided with an input connector and output connectors/terminals for connection to a single-phase power source. Made for building-in, and used with Information Technology Equipment, Including Electrical business equipment. * File E123535 Vol. 2 Sec. 10 and Report ELECTRICAL RATING: Inputs: 115/230 V ac, 47-63 Hz, 9/5 A. 300 V dc, 3 A Outputs: Up to four rated 2-48 V dc. OUTPUT POWER: 260Watts 340Watts 450Watts 500Watts 500Watts 500Watts 500Watts 400Watts 450Watts 500Watts 500Watts 500Watts 500Watts 500Watts 500Watts 500Watts 500Watts 500Watts 500Watts max max max max max max max max max max max max max max max max max max max @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ @ 90V ac 95V ac 100V ac 105V ac 115V ac 125V ac 132V ac 180V ac 185V ac 190V ac 195V ac 200V ac 205V ac 215V ac 225V ac 235V ac 245V ac 255V ac 265V ac Page 1A Issued: New: 2003-05-15 2007-04-02 File E123535 Vol. 2 Sec. 10 and Report Page 2 Issued: Revised: 2003-05-15 2007-04-02 ENGINEERING CONSIDERATIONS (NOT FOR UL REPRESENTATIVE USE): USR/CNR indicates investigation to the Standard for Information *Technology Equipment, Including Electrical Business Equipment, CAN/CSA C22.2 No. 6095000, UL60950, CAN/CSA C22.2 No. 950-95, UL 1950 Third Edition, and the Standard for Information Technology Equipment Including Electrical Business Equipment, UL 60950-1:2003, First Edition; CAN/CSA C22.2 No. 60950-1-03. For use in (or with) complete equipment where the acceptability of the combination is determined by Underwriters Laboratories Inc. Conditions of Acceptability - When installed in the end-use equipment, consideration shall be given to the following: 1. The power supply should be installed in compliance with the enclosure, mounting, spacings, temperature, and casualty and segregation requirements of the ultimate application. These components have been judged on the basis of the required spacings in CAN/CSA C22.2 No.60950-00, CAN/CSA C22.2 No. 950-95, UL 1950 Third Edition, CAN/CSA C22.2 No. 60950-1-03, UL60950-1. 2. The baseplate temperatures of the Vicor DC-DC converter switching power supplies should be measured in the end-use equipment, and should not exceed 85oc for 1st Gen VI-200’s and should not exceed 100°C for 1st Gen VIJ00’s and 2nd Gen Micro, Mini, Maxi families. 3. The acceptability of the input connector and output mating connectors/terminals relative to secureness, insulating materials and temperature should be considered in the end product evaluation. 4. This product has been evaluated as Class I, Component Supply for building-in. 5. VI-200 1st Gen DC-DC Secondary outputs 2V-60V comply with SELV requirements; VI-J00 1st Gen DC-DC Secondary outputs 2V-40V comply with SELV requirements; Micro, Mini, Maxi 2nd Gen DC-DC Secondary outputs 2V-48V comply with SELV requirements; higher voltage outputs are non-SELV. File E123535 Vol. 2 Sec. 10 and Report Page 3 Issued: 2003-05-15 CONSTRUCTION DETAILS: Refer to Section General. MODEL DIFFERENCES: The FlatPAC-EN units use the same Front End Circuitry but differ in the output configurations. They are different in the number of outputs, the Module Complement and the total output power. FlatPAC-EN:(2 outputs) can accommodate the following: 2nd Gen. Mini, 2nd Gen. Maxi or 2nd Gen. Mini, 1st Gen. VI-200 or 1st Gen. VI-J00, 1st Gen. VI-200 or 1st Gen. VI-J00, 2nd Gen. Maxi FlatPAC-EN:(3 outputs) can accommodate the following: 2nd Gen. Mini, Qty 3 or 1st Gen. VI-J00 and 2nd Gen. Mini, Qty 2 or 1st Gen. VI-J00, Qty 3 or 2nd Gen. Mini and 1st Gen. VI-J00, Qty 2 FlatPAC-EN:(4 outputs) can accommodate the following: 2nd Gen. Mini and 2nd Gen. Micro, Qty 3 or 1st Gen. VI-J00 and 2nd Gen. Micro, Qty 3