PDF cURus - UL 60950-1, CSA 60950-1

File E123535
Project 03ME06490
2003-05-15
REPORT
ON
COMPONENT - POWER SUPPLIES, INFORMATION TECHNOLOGY EQUIPMENT,
INCLUDING ELECTRICAL BUSINESS EQUIPMENT
Westcor, Div. Of Vicor Corp.
Sunnyvale, CA
Copyright © 2003 Underwriters Laboratories Inc.
Underwriters Laboratories Inc. authorizes the above-named company to
reproduce this Report provided it is reproduced in its entirety.
Underwriters Laboratories Inc. authorizes the above-named company to
reproduce that portion of this Report consisting of this Cover Page through
Page 2.
File E123535
Vol. 2
Sec. 10
and Report
Page 1
Issued:
Revised:
2003-05-15
2007-04-02
DESCRIPTION
PRODUCT COVERED:
USR, CNR - Component AC-DC Switching Power Supplies, FlatPAC-EN Series,
Model Fla-bc-dddddd-ee-xx.
Item 0. Number of Outputs
a = any number 0-4 (note: each output can be rated 0-95 V dc)
Item 1. Module Configuration
b = Total number of VI-200 and/or VI-J00 Series DC/DC Converters
c = Total number of 2nd Gen Series DC/DC Converters.
Item 2. Factory assigned Code (Non-safety related)
dddddd = any alphanumeric combination or blanks
Item 3. FlatPAC configuration Revision (Optional)
ee = any alphanumeric combination or blanks (note: ee = G for
RoHs compliant)
Item 3. FlatPAC description (Optional)
xx = Optional, any alphanumeric combination or blanks
(note: xx = LL for low leakage models)
(note: xx = E for extended temperature version)
GENERAL CHARACTER AND USE:
The FlatPAC-EN Models are built using up to four Recognized Component
(QQGQ2) Vicor DC-DC switching power supplies, which provide reinforced
insulation between their inputs and outputs.
The FlatPAC-EN Model FLa-bc-dddddd-ee-xx Power Supplies are an enclosed
assembly provided with an input connector and output connectors/terminals for
connection to a single-phase power source. Made for building-in, and used
with Information Technology Equipment, Including Electrical business
equipment.
*
File E123535
Vol. 2
Sec. 10
and Report
ELECTRICAL RATING:
Inputs:
115/230 V ac, 47-63 Hz, 9/5 A.
300 V dc, 3 A
Outputs:
Up to four rated 2-48 V dc.
OUTPUT POWER:
260Watts
340Watts
450Watts
500Watts
500Watts
500Watts
500Watts
400Watts
450Watts
500Watts
500Watts
500Watts
500Watts
500Watts
500Watts
500Watts
500Watts
500Watts
500Watts
max
max
max
max
max
max
max
max
max
max
max
max
max
max
max
max
max
max
max
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
@
90V ac
95V ac
100V ac
105V ac
115V ac
125V ac
132V ac
180V ac
185V ac
190V ac
195V ac
200V ac
205V ac
215V ac
225V ac
235V ac
245V ac
255V ac
265V ac
Page 1A
Issued:
New:
2003-05-15
2007-04-02
File E123535
Vol. 2
Sec. 10
and Report
Page 2
Issued:
Revised:
2003-05-15
2007-04-02
ENGINEERING CONSIDERATIONS (NOT FOR UL REPRESENTATIVE USE):
USR/CNR indicates investigation to the Standard for Information *Technology
Equipment, Including Electrical Business Equipment, CAN/CSA C22.2 No. 6095000, UL60950, CAN/CSA C22.2 No. 950-95, UL 1950 Third Edition, and the
Standard for Information Technology Equipment Including Electrical Business
Equipment, UL 60950-1:2003, First Edition; CAN/CSA C22.2 No. 60950-1-03.
For use in (or with) complete equipment where the acceptability of the
combination is determined by Underwriters Laboratories Inc.
Conditions of Acceptability - When installed in the end-use equipment,
consideration shall be given to the following:
1.
The power supply should be installed in compliance with the
enclosure, mounting, spacings, temperature, and casualty and segregation
requirements of the ultimate application. These components have been judged
on the basis of the required spacings in CAN/CSA C22.2 No.60950-00, CAN/CSA
C22.2 No. 950-95, UL 1950 Third Edition, CAN/CSA C22.2 No. 60950-1-03,
UL60950-1.
2.
The baseplate temperatures of the Vicor DC-DC converter switching
power supplies should be measured in the end-use equipment, and should not
exceed 85oc for 1st Gen VI-200’s and should not exceed 100°C for 1st Gen VIJ00’s and 2nd Gen Micro, Mini, Maxi families.
3.
The acceptability of the input connector and output mating
connectors/terminals relative to secureness, insulating materials and
temperature should be considered in the end product evaluation.
4.
This product has been evaluated as Class I, Component Supply for
building-in.
5.
VI-200 1st Gen DC-DC Secondary outputs 2V-60V comply with SELV
requirements; VI-J00 1st Gen DC-DC Secondary outputs 2V-40V comply with SELV
requirements; Micro, Mini, Maxi 2nd Gen DC-DC Secondary outputs 2V-48V comply
with SELV requirements; higher voltage outputs are non-SELV.
File E123535
Vol. 2
Sec. 10
and Report
Page 3
Issued:
2003-05-15
CONSTRUCTION DETAILS: Refer to Section General.
MODEL DIFFERENCES:
The FlatPAC-EN units use the same Front End Circuitry but differ in the
output configurations. They are different in the number of outputs, the
Module Complement and the total output power.
FlatPAC-EN:(2 outputs) can accommodate the following:
2nd Gen. Mini, 2nd Gen. Maxi
or
2nd Gen. Mini, 1st Gen. VI-200
or
1st Gen. VI-J00, 1st Gen. VI-200
or
1st Gen. VI-J00, 2nd Gen. Maxi
FlatPAC-EN:(3 outputs) can accommodate the following:
2nd Gen. Mini, Qty 3
or
1st Gen. VI-J00 and 2nd Gen. Mini, Qty 2
or
1st Gen. VI-J00, Qty 3
or
2nd Gen. Mini and 1st Gen. VI-J00, Qty 2
FlatPAC-EN:(4 outputs) can accommodate the following:
2nd Gen. Mini and 2nd Gen. Micro, Qty 3
or
1st Gen. VI-J00 and 2nd Gen. Micro, Qty 3