PDF cURus UL 60950-1, CSA 60950-1

1285 Walt
Whitman Road
Melville, New
York 11747-3081
(516) 271-6200
FAX No. (516)
271-8259/8260
http://www.ul.co
m
File E123535
Project 93SC14614
Issued: December 16, 1993
Revised: February 25, 2009
REPORT
on
COMPONENT - POWER SUPPLIES,
INFORMATION TECHNOLOGY EQUIPMENT,
INCLUDING ELECTRICAL BUSINESS EQUIPMENT
Vicor Corp.
Andover, MA
Copyright © 1993 Underwriters Laboratories Inc.
Underwriters Laboratories Inc. authorizes the above-named company to
reproduce this Report provided it is reproduced in its entirety.
Underwriters Laboratories Inc. authorizes the above-named company to
reproduce that portion of this Report consisting of this Cover Page through
Page 2.
File E123535
Vol. 2
Sec. 2
and Report
Page 1
Issued:
Revised:
1993-12-16
2012-06-14
D E S C R I P T I O N
PRODUCT COVERED:
USR, CNR - Component - Switching Power Supply, Mini MegaPAC Series,
Model Mpaa-zbbcccccc-dd-xx.
Mp may be replaced by MM, IMM, or IMP
Item 0.
MegaPAC Type
z = 1 for Mini MegaPAC
Item 1.
Number of Outputs
aa = any number 0 - 20
Item 2.
Number of Modules and FlexPACs
bb = any number 0 – 10
Item 3.
Factory assigned Code (Non-safety related)
cccccc = any alphanumeric combination of up to 6 characters or
blanks
Item 4.
MegaPAC configuration Revision (Optional)
dd = any alphanumeric character or blanks (note: dd = G for RoHs
compliant)
Item 5.
MegaPAC description (Optional)
xx = any alphanumeric combination or blanks (note: xx = LL for
Low Leakage, MI = Mil COTS)
ELECTRICAL RATING:
Input
Model
Mini MegaPAC
V
115-230
or 100-240 Vac
300 Vdc, 6A
A
25/15
Hz
47-500
Output, (dc)
V
0-95
A
200 max
File E123535
Vol. 2
Sec. 2
and Report
Page 1A
Issued:
Revised:
1993-12-16
2012-06-14
ENGINEERING CONSIDERATIONS (NOT FOR UL REPRESENTATIVE USE):
The Model Mini MegaPAC is built using up to five Recognized (QQGQ2) dcdc converter modules and/or FlexPACs. It can be configured by selecting the
desired output voltages of the modules and paralleling similar outputs to
provide the output configurations described in the Rating section of this
report. All units share the same front end primary circuitry and fan
cooling. Finished power supply assemblies are intended to be factory
connected within electronic data processing equipment or information
technology equipment. The signal connector J10 and the DC power output
terminals are considered to be SELV.
*
USR/CNR indicates investigation to the U.S. and Canadian (Bi-National)
Standard for Safety of Information Technology Equipment, ANSI/UL60950-1-2011,
dated December 19, 2011 and CAN/CSA C22.2 No. 60950-1-07, 2nd Edition +
A1:2011 (MOD).
Use - For use only in end-use equipment where the acceptability of the
combination is determined by Underwriters Laboratories Inc.
Special Considerations - The following items are considerations that
were used when evaluating this product.
File E123535
Vol. 2
Sec. 2
and Report
Page 2
Issued:
Revised:
1993-12-16
2012-06-14
The component was submitted by the manufacturer for use in a maximum air
ambient of 40°C.
Maximum 1000 W continuous output with 38 cfm forced air cooling.
Conditions of Acceptability - When installed in the end-use equipment,
consideration shall be given to the following:
1.
These components have been judged on the basis of the required
spacings in the Standard for Safety of Information Technology
Equipment, CAN/CSA C22.2 No. 60950-1-07, 2nd Edition + A1:2011
(MOD)/ ANSI/UL60950-1-2011, dated December 19, 2011, Sub. Clause
2.10, which would cover the component itself, if submitted for
Listing. Minimum spacings between live parts of opposite
polarity and between live and dead-metal parts shall be as
indicated in Tables 2M and 2N in UL/CSA 60950-1. Spacings
(creepages and clearances) are based on the provision of Basic
Insulation.
*
2.
An acceptable enclosure shall be provided in the end-use.
3.
The terminals and connectors are suitable for factory wiring
only.
4.
This power supply was evaluated for connection to a TN power
system.
5.
This power supply is considered a Class I product. The power
supply shall be properly bonded to the main earthing termination
in the end-use.
6.
Bonding terminals provided on this equipment have not been
evaluated as protective earthing terminals.
7.
The secondary outputs of this power supply are considered SELV up
to 48 V.
8.
This power supply has secondary outputs that exceed 240 VA at a
potential of 2 V or more.
9.
This power supply has been evaluated for use in 40°C ambient.
10.
All isolating transformer employ a Class A electrical insulation
system.
11.
The individual modules which comprise this unit have earth
leakage currents which exceed 3.5 mA at high frequency inputs.
For end-product units which operate at input frequencies higher
than 63 Hz, the end-product must be provided with industrial type
sockets or plugs, and the cross-sectional area of the internal
protective earthing conductor may not be less than 1.0 square mm,
or the end-product must be additionally evaluated with respect to
leakage currents, requirements of UL 60950.