SAG AND TENSION TABLES FOR LASHED CABLES ON 1/4 INCH STRAND
LIGHT LOADING AREAS
0.5" DIAMETER (0.2 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
0
4
200
1100
1
6
300
1100
3
3
400
1100
5
10
500
1100
9
1
600
1100
13
2
700
1100
17
10
800
1100
23
4
900
1100
29
7
920
1100
30
10
SAG UNDER
EXPECTED TENSION
HEAVY LOADING UNDER HEAVY LOAD
(Feet) - (Inches)
(Lbs.)
0
10
1162
3
3
1237
6
9
1328
11
3
1422
16
6
1513
22
5
1598
29
1
1678
36
5
1751
44
5
1818
46
1
1831
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
1
2
7
4
8
7
5
10
11
15
1
19
11
25
6
31
10
33
2
0.6" DIAMETER (0.25 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
0
5
200
1100
1
8
300
1100
3
10
400
1100
6
9
500
1100
10
6
600
1100
15
2
700
1100
20
8
800
1100
27
0
810
1100
27
8
SAG UNDER
EXPECTED TENSION UNLOADED SAG
HEAVY LOADING UNDER HEAVY LOAD
AFTER STORM
(Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
0
11
1169
1
2
3
6
1254
2
9
7
4
1356
5
1
12
2
1457
8
3
17
10
1552
12
2
24
4
1640
16
11
31
7
1720
22
6
39
7
1793
28
11
40
5
1800
29
7
0.7" DIAMETER (0.3 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
0
6
200
1100
1
11
300
1100
4
4
400
1100
7
8
500
1100
12
0
600
1100
17
3
700
1100
23
5
730
1100
25
6
SAG UNDER
EXPECTED TENSION
HEAVY LOADING UNDER HEAVY LOAD
(Feet) - (Inches)
(Lbs.)
1
0
1175
3
10
1272
7
11
1383
13
1
1490
19
2
1589
26
2
1678
34
0
1758
36
6
1781
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
2
2
11
5
6
9
0
13
5
18
10
25
1
27
2
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/02/04
Page 1 of 5
SAG AND TENSION TABLES FOR LASHED CABLES ON 1/4 INCH STRAND
LIGHT LOADING AREAS
0.8" DIAMETER (0.4 #/FT.) FILLED FOAM-SKIN CABLE
SAG UNDER
EXPECTED TENSION UNLOADED SAG
SPAN LENGTH
STRINGING
STRINGING SAG HEAVY LOADING UNDER HEAVY LOAD AFTER STORM
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
100
1100
0
7
1
2
1182
1
3
200
1100
2
4
4
3
1288
3
3
300
1100
5
4
8
9
1402
6
4
400
1100
9
6
14
5
1509
10
7
500
1100
14
10
21
3
1603
16
0
600
1100
21
4
29
1
1684
22
7
625
1100
23
2
31
3
1703
24
5
0.9" DIAMETER (0.5 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
0
8
200
1100
2
10
300
1100
6
4
400
1100
11
3
500
1100
17
8
545
1100
21
0
SAG UNDER
EXPECTED TENSION
HEAVY LOADING UNDER HEAVY LOAD
(Feet) - (Inches)
(Lbs.)
1
3
1188
4
8
1303
9
7
1419
15
10
1522
23
5
1610
27
3
1645
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
3
3
7
7
3
12
3
18
8
22
0
1.0" DIAMETER (0.7 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
0
11
200
1100
3
9
300
1100
8
5
400
1100
14
11
440
1100
18
1
SAG UNDER
EXPECTED TENSION
HEAVY LOADING UNDER HEAVY LOAD
(Feet) - (Inches)
(Lbs.)
1
5
1194
5
3
1309
11
0
1415
18
5
1501
21
11
1530
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
5
4
4
9
1
15
8
18
10
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/02/04
Page 2 of 5
SAG AND TENSION TABLES FOR LASHED CABLES ON 1/4 INCH STRAND
LIGHT LOADING AREAS
1.1" DIAMETER (0.8 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
1
1
200
1100
4
2
300
1100
9
5
400
1100
16
9
SAG UNDER
EXPECTED TENSION
HEAVY LOADING UNDER HEAVY LOAD
(Feet) - (Inches)
(Lbs.)
1
7
1201
5
8
1321
11
10
1425
20
0
1506
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
6
4
9
10
0
17
5
1.2" DIAMETER (0.9 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
1
2
200
1100
4
8
300
1100
10
5
365
1100
15
5
SAG UNDER
EXPECTED TENSION
HEAVY LOADING UNDER HEAVY LOAD
(Feet) - (Inches)
(Lbs.)
1
8
1207
6
1
1331
12
9
1434
18
3
1485
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
7
5
2
11
0
16
1
1.3" DIAMETER (1.2 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
1
6
200
1100
6
0
295
1100
13
1
SAG UNDER
EXPECTED TENSION
HEAVY LOADING UNDER HEAVY LOAD
(Feet) - (Inches)
(Lbs.)
1
11
1210
7
2
1321
14
8
1395
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
10
6
5
13
6
1.4" DIAMETER (1.4 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
1
9
200
1100
6
11
260
1100
11
8
SAG UNDER
EXPECTED TENSION
HEAVY LOADING UNDER HEAVY LOAD
(Feet) - (Inches)
(Lbs.)
2
2
1214
7
11
1318
12
11
1361
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
2
0
7
3
12
1
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/02/04
Page 3 of 5
SAG AND TENSION TABLES FOR LASHED CABLES ON 1/4 INCH STRAND
LIGHT LOADING AREAS
1.5" DIAMETER (1.5 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
1
10
200
1100
7
4
245
1100
11
1
SAG UNDER
EXPECTED TENSION
HEAVY LOADING UNDER HEAVY LOAD
(Feet) - (Inches)
(Lbs.)
2
3
1220
8
4
1324
12
3
1357
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
2
2
7
8
11
5
1.6" DIAMETER (1.8 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
2
2
200
1100
8
9
210
1100
9
8
SAG UNDER
EXPECTED TENSION
HEAVY LOADING UNDER HEAVY LOAD
(Feet) - (Inches)
(Lbs.)
2
7
1220
9
6
1309
10
5
1315
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
2
5
9
0
9
11
1.7" DIAMETER (2.1 #/FT.) FILLED FOAM-SKIN CABLE
SAG UNDER
EXPECTED TENSION UNLOADED SAG
SPAN LENGTH
STRINGING
STRINGING SAG
HEAVY
UNDER HEAVY LOAD AFTER STORM
(Feet)
TENSION(Lbs.) (Feet) - (Inches) (Feet) - (Inches)
(Lbs.)
(Feet) - (Inches)
100
1100
2
6
2
10
1219
2
9
185
1100
8
8
9
3
1286
8
11
1.8" DIAMETER (2.4 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
2
10
165
1100
7
10
SAG UNDER
EXPECTED TENSION
HEAVY LOADING UNDER HEAVY LOAD
(Feet) - (Inches)
(Lbs.)
3
2
1217
8
3
1264
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
3
1
8
0
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/02/04
Page 4 of 5
SAG AND TENSION TABLES FOR LASHED CABLES ON 1/4 INCH STRAND
LIGHT LOADING AREAS
1.9" DIAMETER (2.6 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
3
1
150
1100
6
11
SAG UNDER
EXPECTED TENSION
HEAVY LOADING UNDER HEAVY LOAD
(Feet) - (Inches)
(Lbs.)
3
4
1218
7
4
1254
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
3
3
7
2
2.0" DIAMETER (2.7 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
1100
3
2
145
1100
6
9
SAG UNDER
EXPECTED TENSION
HEAVY LOADING UNDER HEAVY LOAD
(Feet) - (Inches)
(Lbs.)
3
6
1222
7
1
1255
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
3
5
6
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/02/04
Page 5 of 5
11