SAG AND TENSION TABLES FOR LIGHT LOADING AREAS
22 AWG DOUBLE JACKET FIGURE 8
BHAP-25
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
7
75
300
1
3
100
300
2
2
125
300
3
5
150
300
4
11
175
300
6
8
200
400
6
6
225
400
8
3
250
500
8
2
275
500
9
10
300
600
9
9
325
600
11
5
350
600
13
3
375
700
13
1
400
700
14
10
425
800
14
8
450
900
14
8
475
900
16
4
500
1000
16
3
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
0
11
1
10
2
11
4
4
5
11
7
10
8
3
10
2
10
8
12
7
13
2
15
1
17
2
17
8
19
9
20
4
21
0
23
1
23
9
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
435
488
531
564
591
612
757
780
915
939
1068
1093
1115
1241
1265
1386
1502
1527
1641
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
7
1
3
2
3
3
6
5
0
6
9
6
8
8
5
8
4
10
1
10
1
11
9
13
7
13
6
15
3
15
2
15
3
16
11
17
0
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
439
486
519
543
560
708
726
867
999
1022
1150
1273
1297
1418
1442
1561
1677
1791
1816
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
9
1
8
2
11
4
7
6
6
6
8
8
9
8
11
9
2
11
1
11
5
11
9
13
7
13
11
15
10
16
2
16
6
17
0
18
9
BHAP-50
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
9
75
300
1
7
100
300
2
11
125
300
4
6
150
300
6
6
175
400
6
7
200
400
8
7
225
500
8
9
250
600
9
0
275
600
10
10
300
700
11
1
325
800
11
5
350
800
13
2
375
900
13
6
400
900
15
4
425
1000
15
7
450
1100
15
11
475
1200
16
3
500
1200
18
0
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
1
0
2
1
3
6
5
2
7
3
7
9
9
11
10
6
11
3
13
4
14
1
14
11
16
11
17
10
19
11
20
9
21
8
22
8
24
9
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/08/04
Page 1 of 12
SAG AND TENSION TABLES FOR LIGHT LOADING AREAS
22 AWG DOUBLE JACKET FIGURE 8
BHAP-100
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
1
1
75
300
2
4
100
300
4
2
125
400
4
11
150
400
7
0
175
500
7
8
200
600
8
4
225
700
9
0
250
800
9
9
275
900
10
6
300
1000
11
3
325
1100
12
0
350
1200
12
9
375
1200
14
8
400
1300
15
5
425
1400
16
2
450
1500
16
11
475
1600
17
8
500
1700
18
5
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
1
3
2
8
4
7
5
6
7
9
8
8
9
8
10
9
11
10
13
0
14
2
15
4
16
6
18
8
19
10
21
0
22
3
23
6
24
9
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
443
477
498
642
660
801
936
1067
1195
1319
1442
1563
1682
1709
1827
1944
2059
2174
2288
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
1
2
5
4
2
4
11
7
1
7
9
8
6
9
3
10
0
10
10
11
7
12
5
13
3
15
2
16
0
16
10
17
8
18
6
19
4
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/08/04
Page 2 of 12
SAG AND TENSION TABLES FOR LIGHT LOADING AREAS
22 AWG SINGLE JACKET FIGURE 8
BHAS-25
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
4
75
300
0
10
100
300
1
5
125
300
2
3
150
300
3
2
175
300
4
4
200
300
5
8
225
300
7
2
250
300
8
10
275
300
10
9
300
350
10
11
325
400
11
3
350
450
11
7
375
500
11
11
400
500
13
7
425
500
15
4
450
600
14
4
475
600
16
0
500
600
17
8
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
0
9
1
6
2
5
3
6
4
8
6
1
7
7
9
3
11
2
13
2
13
11
14
10
15
10
16
10
18
9
20
10
20
11
22
10
24
11
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
418
472
520
561
597
628
655
678
698
716
802
884
962
1038
1060
1080
1206
1228
1249
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
5
0
11
1
6
2
4
3
4
4
6
5
10
7
4
9
0
10
10
11
2
11
6
11
11
12
4
14
0
15
9
14
10
16
6
18
3
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
430
484
527
562
590
613
697
778
858
935
958
1086
1110
1132
1256
1279
1399
1422
1538
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
7
1
2
2
1
3
3
4
7
6
3
7
0
7
9
8
6
9
4
11
1
10
11
12
7
14
5
14
2
15
11
15
9
17
6
17
4
BHAS-50
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
6
75
300
1
2
100
300
2
0
125
300
3
2
150
300
4
6
175
300
6
2
200
350
6
10
225
400
7
7
250
450
8
4
275
500
9
1
300
500
10
10
325
600
10
7
350
600
12
3
375
600
14
1
400
700
13
9
425
700
15
6
450
800
15
2
475
800
16
11
500
900
16
8
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
0
10
1
9
2
10
4
1
5
8
7
5
8
6
9
7
10
9
11
11
13
11
14
5
16
4
18
4
18
10
20
10
21
5
23
5
24
0
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/08/04
Page 3 of 12
SAG AND TENSION TABLES FOR LIGHT LOADING AREAS
22 AWG SINGLE JACKET FIGURE 8
BHAS-100
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
9
75
300
1
9
100
300
3
2
125
300
4
11
150
350
6
0
175
400
7
2
200
500
7
6
225
550
8
8
250
600
9
9
275
700
10
2
300
700
12
1
325
800
12
5
350
900
12
9
375
1000
13
2
400
1000
15
0
425
1100
15
5
450
1200
15
10
475
1300
16
3
500
1300
18
0
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
1
1
2
2
3
8
5
6
6
11
8
3
9
0
10
5
11
11
12
9
14
11
15
9
16
8
17
8
19
9
20
9
21
9
22
9
24
10
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
444
489
521
543
627
709
849
928
1006
1135
1159
1285
1407
1527
1552
1670
1786
1900
1926
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
10
1
10
3
2
4
11
6
1
7
3
7
8
8
10
10
0
10
5
12
4
12
9
13
2
13
8
15
6
16
0
16
6
17
1
18
10
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/08/04
Page 4 of 12
SAG AND TENSION TABLES FOR LIGHT LOADING AREAS
24 AWG DOUBLE JACKET FIGURE 8
BKMP-25
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
6
75
300
1
2
100
300
2
0
125
300
3
2
150
300
4
6
175
300
6
2
200
300
8
0
225
400
7
7
250
400
9
5
275
400
11
4
300
500
10
10
325
500
12
8
350
600
12
3
375
600
14
1
400
700
13
9
425
700
15
6
450
800
15
2
475
800
16
11
500
900
16
8
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
0
10
1
8
2
9
4
0
5
6
7
3
9
3
9
5
11
4
13
5
13
7
15
8
16
0
18
0
18
5
20
5
20
11
22
11
23
5
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
419
468
507
539
564
584
601
744
763
780
917
936
1064
1084
1207
1227
1345
1366
1480
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
7
1
2
2
1
3
2
4
7
6
3
8
1
7
9
9
6
11
6
11
0
12
11
12
7
14
5
14
2
15
11
15
9
17
6
17
4
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
437
489
529
559
583
601
750
770
909
931
1063
1086
1213
1236
1359
1477
1591
1617
1730
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
8
1
5
2
5
3
9
5
5
7
4
7
3
9
2
9
1
11
0
11
0
12
10
12
10
14
8
14
9
14
10
15
1
16
9
17
0
BKMP-50
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
7
75
300
1
4
100
300
2
4
125
300
3
9
150
300
5
4
175
300
7
3
200
400
7
1
225
400
9
0
250
500
8
11
275
500
10
9
300
600
10
8
325
600
12
7
350
700
12
6
375
700
14
4
400
800
14
3
425
900
14
4
450
1000
14
5
475
1000
16
1
500
1100
16
2
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
0
11
1
11
3
1
4
7
6
4
8
4
8
9
10
9
11
3
13
3
13
10
15
11
16
6
18
7
19
3
20
0
20
9
22
10
23
7
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/08/04
Page 5 of 12
SAG AND TENSION TABLES FOR LIGHT LOADING AREAS
24 AWG DOUBLE JACKET FIGURE 8
BKMP-100
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
10
75
300
1
10
100
300
3
3
125
300
5
1
150
400
5
6
175
400
7
6
200
500
7
10
225
600
8
3
250
600
10
2
275
700
10
6
300
800
11
0
325
800
12
10
350
900
13
3
375
1000
13
9
400
1100
14
2
425
1100
16
0
450
1200
16
5
475
1300
16
11
500
1400
17
5
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
1
1
2
3
3
9
5
8
6
5
8
6
9
3
10
1
12
2
13
0
14
0
16
1
17
0
18
0
19
0
21
1
22
1
23
2
24
2
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
442
485
515
535
680
699
840
972
995
1125
1250
1274
1397
1517
1634
1660
1776
1890
2003
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
10
1
10
3
4
5
2
5
7
7
7
7
11
8
5
10
4
10
9
11
3
13
2
13
8
14
2
14
9
16
7
17
1
17
8
18
3
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
436
463
602
738
759
893
1023
1151
1276
1400
1522
1642
1762
1880
1997
2113
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
3
2
9
3
8
4
8
6
8
7
7
8
6
9
5
10
5
11
4
12
4
13
3
14
3
15
3
16
3
17
3
BKMP-200
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
1
3
75
300
2
9
100
400
3
8
125
500
4
7
150
500
6
7
175
600
7
6
200
700
8
4
225
800
9
3
250
900
10
2
275
1000
11
1
300
1100
12
0
325
1200
12
10
350
1300
13
9
375
1400
14
8
400
1500
15
7
425
1600
16
6
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
1
5
3
0
4
1
5
3
7
4
8
6
9
8
10
10
12
1
13
4
14
7
15
10
17
2
18
5
19
9
21
1
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/08/04
Page 6 of 12
SAG AND TENSION TABLES FOR LIGHT LOADING AREAS
24 AWG SINGLE JACKET FIGURE 8
BKMS-25
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
4
75
300
0
8
100
300
1
3
125
300
1
11
150
300
2
9
175
300
3
8
200
300
4
10
225
300
6
1
250
300
7
7
275
300
9
2
300
300
10
11
325
350
10
11
350
400
11
1
375
400
12
9
400
450
12
11
425
500
13
1
450
500
14
8
475
550
14
10
500
550
16
6
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
0
8
1
5
2
3
3
3
4
4
5
8
7
0
8
6
10
2
12
0
13
11
14
8
15
6
17
5
18
3
19
3
21
2
22
1
24
1
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
413
466
514
557
595
629
659
685
709
730
749
834
914
934
1012
1086
1108
1180
1201
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
5
0
9
1
4
2
0
2
10
3
10
5
0
6
4
7
9
9
4
11
1
11
2
11
5
13
1
13
3
13
7
15
2
15
5
17
0
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
423
477
524
564
598
627
651
672
690
776
859
878
959
1037
1112
1186
1207
1280
1351
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
6
1
0
1
8
2
7
3
8
5
0
6
6
8
2
10
0
10
5
10
11
12
9
13
3
13
8
14
3
14
9
16
6
17
0
17
7
BKMS-50
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
5
75
300
0
11
100
300
1
7
125
300
2
6
150
300
3
7
175
300
4
10
200
300
6
4
225
300
8
0
250
300
9
11
275
350
10
3
300
400
10
8
325
400
12
7
350
450
12
11
375
500
13
4
400
550
13
10
425
600
14
4
450
600
16
0
475
650
16
6
500
700
17
0
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
0
9
1
7
2
6
3
8
4
11
6
5
8
1
9
11
11
11
12
10
13
10
15
10
16
10
17
10
18
11
20
1
22
1
23
3
24
5
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/08/04
Page 7 of 12
SAG AND TENSION TABLES FOR LIGHT LOADING AREAS
24 AWG SINGLE JACKET FIGURE 8
BKMS-100
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
7
75
300
1
4
100
300
2
4
125
300
3
8
150
300
5
3
175
300
7
2
200
350
8
0
225
400
8
10
250
450
9
9
275
500
10
7
300
550
11
5
325
600
12
4
350
650
13
2
375
700
14
1
400
750
14
11
425
800
15
10
450
850
16
8
475
900
17
7
500
1000
17
6
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
0
11
1
10
3
1
4
6
6
3
8
2
9
5
10
7
11
10
13
1
14
4
15
8
17
0
18
4
19
8
21
1
22
6
23
10
24
7
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
435
486
526
557
580
599
684
766
847
926
1004
1080
1155
1229
1302
1374
1446
1516
1632
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
8
1
5
2
5
3
9
5
4
7
3
8
1
9
0
9
11
10
10
11
8
12
7
13
6
14
5
15
4
16
3
17
3
18
2
18
3
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
434
471
494
509
653
790
809
942
1071
1195
1218
1341
1461
1579
1696
1719
1835
1949
2062
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
11
2
1
3
9
5
9
6
3
6
10
8
11
9
5
10
0
10
8
12
8
13
3
13
11
14
7
15
3
17
2
17
10
18
6
19
2
BKMS-200
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
11
75
300
2
1
100
300
3
8
125
300
5
9
150
400
6
2
175
500
6
9
200
500
8
10
225
600
9
3
250
700
9
10
275
800
10
5
300
800
12
5
325
900
12
11
350
1000
13
6
375
1100
14
1
400
1200
14
8
425
1200
16
7
450
1300
17
2
475
1400
17
9
500
1500
18
4
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
1
2
2
5
4
1
6
2
6
11
7
10
10
0
10
10
11
9
12
9
14
11
15
11
16
11
17
11
19
0
21
2
22
3
23
4
24
5
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/08/04
Page 8 of 12
SAG AND TENSION TABLES FOR LIGHT LOADING AREAS
26 AWG DOUBLE JACKET FIGURE 8
BKTP-25
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
5
75
300
0
11
100
300
1
8
125
300
2
7
150
300
3
9
175
300
5
1
200
300
6
8
225
300
8
5
250
350
8
11
275
400
9
5
300
400
11
3
325
500
10
7
350
500
12
3
375
500
14
1
400
600
13
4
425
600
15
1
450
700
14
6
475
700
16
1
500
800
15
8
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
0
10
1
7
2
7
3
9
5
1
6
8
8
4
10
3
11
3
12
4
14
3
14
6
16
5
18
6
18
8
20
8
21
1
23
1
23
6
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
427
482
530
569
603
631
655
675
761
843
864
1000
1023
1044
1173
1196
1317
1341
1456
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
6
1
0
1
9
2
9
3
10
5
3
6
9
8
7
9
1
9
8
11
6
10
10
12
7
14
5
13
9
15
6
15
0
16
8
16
4
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
433
488
532
568
597
620
639
725
809
828
910
990
1122
1144
1269
1293
1413
1436
1553
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
7
1
2
2
1
3
3
4
7
6
3
8
1
8
10
9
7
11
6
12
3
12
11
12
7
14
5
14
2
15
11
15
9
17
6
17
5
BKTP-50
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
6
75
300
1
2
100
300
2
0
125
300
3
2
150
300
4
6
175
300
6
2
200
300
8
0
225
350
8
8
250
400
9
5
275
400
11
4
300
450
12
0
325
500
12
8
350
600
12
3
375
600
14
1
400
700
13
9
425
700
15
6
450
800
15
2
475
800
16
11
500
900
16
8
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
0
10
1
9
2
10
4
2
5
8
7
5
9
5
10
6
11
7
13
9
14
10
16
0
16
5
18
6
18
11
21
0
21
6
23
7
24
2
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/08/04
Page 9 of 12
SAG AND TENSION TABLES FOR LIGHT LOADING AREAS
26 AWG DOUBLE JACKET FIGURE 8
BKTP-100
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
8
75
300
1
5
100
300
2
7
125
300
4
0
150
300
5
10
175
350
6
9
200
400
7
9
225
450
8
9
250
500
9
8
275
600
9
9
300
600
11
8
325
700
11
8
350
700
13
7
375
800
13
7
400
900
13
9
425
900
15
7
450
1000
15
8
475
1100
15
11
500
1100
17
7
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
1
0
2
0
3
3
4
10
6
9
8
0
9
3
10
7
11
11
12
7
14
8
15
4
17
5
18
2
19
0
21
1
21
11
22
9
24
10
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
443
495
534
563
585
671
755
837
917
1050
1074
1202
1227
1351
1471
1497
1614
1729
1755
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
8
1
6
2
8
4
1
5
11
6
11
7
10
8
10
9
10
10
0
11
11
12
0
13
11
14
1
14
4
16
1
16
4
16
8
18
5
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
443
482
508
590
671
810
943
966
1097
1223
1346
1372
1493
1613
1731
1847
1961
1988
2102
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
11
2
1
3
9
5
0
6
3
6
10
7
6
9
5
10
0
10
8
11
4
13
3
13
11
14
7
15
3
15
11
16
8
18
6
19
3
BKTP-200
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
11
75
300
2
1
100
300
3
8
125
350
4
11
150
400
6
2
175
500
6
9
200
600
7
4
225
600
9
3
250
700
9
10
275
800
10
5
300
900
11
0
325
900
12
11
350
1000
13
6
375
1100
14
1
400
1200
14
8
425
1300
15
3
450
1400
15
11
475
1400
17
9
500
1500
18
4
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
1
2
2
5
4
1
5
6
7
0
7
11
8
10
10
11
11
11
12
11
14
0
16
1
17
2
18
3
19
4
20
5
21
7
23
9
24
10
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/08/04
Page 10 of 12
SAG AND TENSION TABLES FOR LIGHT LOADING AREAS
26 AWG SINGLE JACKET FIGURE 8
BKTS-25
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
3
75
300
0
7
100
300
1
1
125
300
1
8
150
300
2
5
175
300
3
4
200
300
4
4
225
300
5
6
250
300
6
9
275
300
8
2
300
300
9
9
325
300
11
5
350
300
13
3
375
350
13
1
400
400
13
0
425
400
14
8
450
400
16
5
475
450
16
4
500
500
16
3
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
0
8
1
4
2
2
3
1
4
2
5
4
6
8
8
1
9
7
11
3
13
0
14
11
16
11
17
6
18
3
20
2
22
3
22
11
23
9
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
406
457
504
547
585
620
651
679
704
727
747
766
783
868
948
967
985
1063
1137
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
4
0
9
1
3
1
10
2
7
3
6
4
6
5
8
7
0
8
5
10
0
11
8
13
6
13
4
13
4
15
1
16
10
16
9
16
9
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
415
469
517
559
596
629
658
683
706
726
743
830
911
931
1010
1085
1106
1180
1251
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
5
0
10
1
5
2
2
3
1
4
1
5
4
6
8
8
3
9
11
11
10
11
11
12
2
13
11
14
2
14
5
16
2
16
5
16
9
BKTS-50
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
4
75
300
0
9
100
300
1
4
125
300
2
0
150
300
2
11
175
300
3
11
200
300
5
2
225
300
6
6
250
300
8
1
275
300
9
9
300
300
11
8
325
350
11
8
350
400
11
10
375
400
13
7
400
450
13
9
425
500
14
0
450
500
15
8
475
550
15
11
500
600
16
2
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
0
9
1
5
2
4
3
4
4
6
5
10
7
3
8
10
10
7
12
5
14
5
15
2
16
1
18
0
18
11
19
10
21
10
22
10
23
10
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/08/04
Page 11 of 12
SAG AND TENSION TABLES FOR LIGHT LOADING AREAS
26 AWG SINGLE JACKET FIGURE 8
BKTS-100
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
5
75
300
1
0
100
300
1
10
125
300
2
10
150
300
4
0
175
300
5
6
200
300
7
2
225
300
9
1
250
350
9
7
275
400
10
2
300
400
12
1
325
500
11
4
350
500
13
2
375
550
13
9
400
600
14
4
425
700
13
10
450
700
15
7
475
700
17
4
500
800
16
10
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
0
10
1
8
2
8
3
10
5
3
6
11
8
8
10
9
11
8
12
9
14
10
14
11
17
0
18
1
19
3
19
8
21
8
23
9
24
2
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
426
479
524
561
592
618
639
656
742
825
843
982
1003
1079
1154
1276
1299
1321
1439
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
6
1
1
1
11
2
11
4
2
5
7
7
3
9
2
9
9
10
4
12
3
11
8
13
5
14
1
14
9
14
5
16
1
17
10
17
5
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
433
480
514
539
558
641
722
801
879
1011
1032
1159
1181
1304
1423
1446
1563
1677
1701
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
0
9
1
7
2
9
4
3
6
1
7
1
8
1
9
2
10
2
10
4
12
3
12
5
14
4
14
6
14
9
16
7
16
10
17
1
18
11
BKTS-200
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
50
300
0
8
75
300
1
6
100
300
2
8
125
300
4
2
150
300
6
0
175
350
7
0
200
400
8
0
225
450
9
0
250
500
10
0
275
600
10
1
300
600
12
0
325
700
12
1
350
700
14
0
375
800
14
1
400
900
14
3
425
900
16
1
450
1000
16
2
475
1100
16
5
500
1100
18
2
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
1
0
2
0
3
3
4
11
6
9
8
1
9
4
10
8
12
0
12
7
14
8
15
4
17
6
18
2
18
11
21
0
21
10
22
8
24
9
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).