SAG AND TENSION TABLES FOR LASHED CABLES ON 10M STRAND LIGHT LOADING AREAS 1.0" DIAMETER (0.7 #/FT.) FILLED FOAM-SKIN CABLE SPAN LENGTH STRINGING STRINGING SAG (Feet) TENSION(Lbs.) (Feet) - (Inches) 100 2100 0 6 200 2100 2 1 300 2100 4 9 400 2100 8 6 500 2100 13 3 600 2100 19 1 700 720 2100 2100 25 27 SAG UNDER EXPECTED TENSION LIGHT LOADING UNDER LIGHT LOAD (Feet) - (Inches) (Lbs.) 0 10 2156 3 4 2218 7 3 2301 12 5 2393 18 8 2485 26 0 2572 11 5 34 36 3 1 2652 2668 UNLOADED SAG AFTER STORM (Feet) - (Inches) 1 3 3 1 5 10 9 8 14 6 20 4 27 28 4 10 1.2" DIAMETER (0.9 #/FT.) FILLED FOAM-SKIN CABLE SPAN LENGTH STRINGING STRINGING SAG (Feet) TENSION(Lbs.) (Feet) - (Inches) 100 2100 0 8 200 2100 2 7 300 400 500 600 610 2100 2100 2100 2100 2100 5 10 16 23 24 SAG UNDER EXPECTED TENSION LIGHT LOADING UNDER LIGHT LOAD (Feet) - (Inches) (Lbs.) 0 12 2162 3 10 2236 10 4 2 4 1 8 14 21 29 30 4 2 4 9 8 2332 2432 2526 2612 2620 UNLOADED SAG AFTER STORM (Feet) - (Inches) 1 3 3 5 6 11 17 24 25 9 4 3 5 3 1.4" DIAMETER (1.4 #/FT.) FILLED FOAM-SKIN CABLE SPAN LENGTH STRINGING STRINGING SAG (Feet) TENSION(Lbs.) (Feet) - (Inches) 100 2100 0 11 200 2100 3 9 300 2100 8 6 400 2100 15 2 450 2100 19 2 SAG UNDER EXPECTED TENSION LIGHT LOADING UNDER LIGHT LOAD (Feet) - (Inches) (Lbs.) 1 3 2167 4 10 2250 10 6 2344 17 12 2431 22 5 2469 UNLOADED SAG AFTER STORM (Feet) - (Inches) 1 5 4 5 9 2 15 10 19 10 NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F). 04/05/04 Page 1 of 2 SAG AND TENSION TABLES FOR LASHED CABLES ON 10M STRAND LIGHT LOADING AREAS 1.6" DIAMETER (1.8 #/FT.) FILLED FOAM-SKIN CABLE SPAN LENGTH STRINGING STRINGING SAG (Feet) TENSION(Lbs.) (Feet) - (Inches) 100 2100 1 2 200 2100 4 9 300 2100 10 8 370 2100 16 2 SAG UNDER EXPECTED TENSION LIGHT LOADING UNDER LIGHT LOAD (Feet) - (Inches) (Lbs.) 1 6 2173 5 9 2263 12 4 2354 18 4 2410 UNLOADED SAG AFTER STORM (Feet) - (Inches) 1 7 5 3 11 2 16 9 1.8" DIAMETER (2.4 #/FT.) FILLED FOAM-SKIN CABLE SPAN LENGTH STRINGING STRINGING SAG (Feet) TENSION(Lbs.) (Feet) - (Inches) 100 2100 1 6 200 295 2100 2100 6 13 SAG UNDER LIGHT LOADING (Feet) - (Inches) 1 10 2 5 6 14 12 8 EXPECTED TENSION UNDER LIGHT LOAD (Lbs.) 2179 2267 2341 UNLOADED SAG AFTER STORM (Feet) - (Inches) 1 11 6 13 7 10 2.0" DIAMETER (2.7 #/FT.) FILLED FOAM-SKIN CABLE SPAN LENGTH STRINGING STRINGING SAG (Feet) TENSION(Lbs.) (Feet) - (Inches) 100 2100 1 9 200 2100 6 11 265 2100 12 1 SAG UNDER EXPECTED TENSION LIGHT LOADING UNDER LIGHT LOAD (Feet) - (Inches) (Lbs.) 1 12 2185 7 8 2278 13 2 2330 UNLOADED SAG AFTER STORM (Feet) - (Inches) 2 1 7 3 12 5 NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F). 04/05/04 Page 2 of 2