Lashed 10M Light Loading

SAG AND TENSION TABLES FOR LASHED CABLES ON 10M STRAND
LIGHT LOADING AREAS
1.0" DIAMETER (0.7 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
2100
0
6
200
2100
2
1
300
2100
4
9
400
2100
8
6
500
2100
13
3
600
2100
19
1
700
720
2100
2100
25
27
SAG UNDER
EXPECTED TENSION
LIGHT LOADING UNDER LIGHT LOAD
(Feet) - (Inches)
(Lbs.)
0
10
2156
3
4
2218
7
3
2301
12
5
2393
18
8
2485
26
0
2572
11
5
34
36
3
1
2652
2668
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
3
3
1
5
10
9
8
14
6
20
4
27
28
4
10
1.2" DIAMETER (0.9 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
2100
0
8
200
2100
2
7
300
400
500
600
610
2100
2100
2100
2100
2100
5
10
16
23
24
SAG UNDER
EXPECTED TENSION
LIGHT LOADING UNDER LIGHT LOAD
(Feet) - (Inches)
(Lbs.)
0
12
2162
3
10
2236
10
4
2
4
1
8
14
21
29
30
4
2
4
9
8
2332
2432
2526
2612
2620
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
3
3
5
6
11
17
24
25
9
4
3
5
3
1.4" DIAMETER (1.4 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
2100
0
11
200
2100
3
9
300
2100
8
6
400
2100
15
2
450
2100
19
2
SAG UNDER
EXPECTED TENSION
LIGHT LOADING UNDER LIGHT LOAD
(Feet) - (Inches)
(Lbs.)
1
3
2167
4
10
2250
10
6
2344
17
12
2431
22
5
2469
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
5
4
5
9
2
15
10
19
10
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/05/04
Page 1 of 2
SAG AND TENSION TABLES FOR LASHED CABLES ON 10M STRAND
LIGHT LOADING AREAS
1.6" DIAMETER (1.8 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
2100
1
2
200
2100
4
9
300
2100
10
8
370
2100
16
2
SAG UNDER
EXPECTED TENSION
LIGHT LOADING UNDER LIGHT LOAD
(Feet) - (Inches)
(Lbs.)
1
6
2173
5
9
2263
12
4
2354
18
4
2410
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
7
5
3
11
2
16
9
1.8" DIAMETER (2.4 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
2100
1
6
200
295
2100
2100
6
13
SAG UNDER
LIGHT LOADING
(Feet) - (Inches)
1
10
2
5
6
14
12
8
EXPECTED TENSION
UNDER LIGHT LOAD
(Lbs.)
2179
2267
2341
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
1
11
6
13
7
10
2.0" DIAMETER (2.7 #/FT.) FILLED FOAM-SKIN CABLE
SPAN LENGTH
STRINGING
STRINGING SAG
(Feet)
TENSION(Lbs.) (Feet) - (Inches)
100
2100
1
9
200
2100
6
11
265
2100
12
1
SAG UNDER
EXPECTED TENSION
LIGHT LOADING UNDER LIGHT LOAD
(Feet) - (Inches)
(Lbs.)
1
12
2185
7
8
2278
13
2
2330
UNLOADED SAG
AFTER STORM
(Feet) - (Inches)
2
1
7
3
12
5
NOTES: Light loading is defined under NESC Rules 250 and 251 as 9 PSF horizontal wind pressure
at 30º Fahrenheit and no ice. Stringing tensions are at 60º (F).
04/05/04
Page 2 of 2