SAG AND TENSION TABLES FOR LASHED CABLES ON 16M STRAND HEAVY ICE LOADING AREAS 1.0" DIAMETER (0.7 #/FT.) FILLED FOAM-SKIN CABLE SPAN LENGTH STRINGING STRINGING SAG (Feet) TENSION(Lbs.) (Feet) - (Inches) 100 3600 0 4 200 3600 1 6 300 3600 3 4 400 3600 5 11 600 3600 13 5 670 3600 16 8 SAG UNDER EXPECTED TENSION HEAVY LOADING UNDER HEAVY LOAD (Feet) - (Inches) (Lbs.) 0 11 3702 3 8 3805 7 10 3953 13 5 4126 27 7 4497 33 6 4627 UNLOADED SAG AFTER STORM (Feet) - (Inches) 1 1 2 7 4 8 7 5 15 1 18 6 1.2" DIAMETER (0.9 #/FT.) FILLED FOAM-SKIN CABLE SPAN LENGTH STRINGING STRINGING SAG (Feet) TENSION(Lbs.) (Feet) - (Inches) 100 3600 0 5 200 3600 1 9 300 3600 3 12 400 3600 7 1 500 3600 11 0 595 3600 15 SAG UNDER EXPECTED TENSION HEAVY LOADING UNDER HEAVY LOAD (Feet) - (Inches) (Lbs.) 1 0 3710 4 0 3833 8 8 4004 14 9 4199 21 11 4402 7 29 9 UNLOADED SAG AFTER STORM (Feet) - (Inches) 1 2 2 9 5 2 8 4 12 5 4593 17 1 1.4" DIAMETER (1.4 #/FT.) FILLED FOAM-SKIN CABLE SPAN LENGTH STRINGING STRINGING SAG (Feet) TENSION(Lbs.) (Feet) - (Inches) 100 3600 0 7 200 3600 2 6 300 3600 5 6 485 3600 14 6 SAG UNDER EXPECTED TENSION HEAVY LOADING UNDER HEAVY LOAD (Feet) - (Inches) (Lbs.) 1 3 3725 4 9 3880 10 2 4084 24 3 4490 UNLOADED SAG AFTER STORM (Feet) - (Inches) 1 3 3 3 6 5 15 6 NOTES: Heavy ice loading is defined under NESC Rules 250 and 251 as 0.5 inch radial thickness of ice and 4 PSF horizontal wind pressure at 0º Fahrenheit. Stringing tession is at 60º F. 04/02/04 Page 1 of 2 SAG AND TENSION TABLES FOR LASHED CABLES ON 16M STRAND HEAVY ICE LOADING AREAS 1.6" DIAMETER (1.8 #/FT.) FILLED FOAM-SKIN CABLE SPAN LENGTH STRINGING STRINGING SAG (Feet) TENSION(Lbs.) (Feet) - (Inches) 100 3600 0 9 200 3600 3 0 420 3600 13 4 SAG UNDER EXPECTED TENSION HEAVY LOADING UNDER HEAVY LOAD (Feet) - (Inches) (Lbs.) 1 5 3738 5 5 3921 21 0 4434 UNLOADED SAG AFTER STORM (Feet) - (Inches) 0 10 3 1 13 5 1.8" DIAMETER (2.4 #/FT.) FILLED FOAM-SKIN CABLE SPAN LENGTH STRINGING STRINGING SAG (Feet) TENSION(Lbs.) (Feet) - (Inches) 100 3600 0 12 200 3600 3 10 300 350 3600 3600 8 11 SAG UNDER EXPECTED TENSION HEAVY LOADING UNDER HEAVY LOAD (Feet) - (Inches) (Lbs.) 1 8 3756 6 3 3972 8 9 13 17 2 5 UNLOADED SAG AFTER STORM (Feet) - (Inches) 1 5 4 5 4225 4350 9 12 4 5 2.0" DIAMETER (2.7 #/FT.) FILLED FOAM-SKIN CABLE SPAN LENGTH STRINGING STRINGING SAG (Feet) TENSION(Lbs.) (Feet) - (Inches) 100 3600 1 1 200 3600 4 3 300 3600 9 7 320 3600 10 11 SAG UNDER EXPECTED TENSION HEAVY LOADING UNDER HEAVY LOAD (Feet) - (Inches) (Lbs.) 1 9 3769 6 8 4008 14 2 4277 15 11 UNLOADED SAG AFTER STORM (Feet) - (Inches) 1 10 5 3 10 8 4330 NOTES: Heavy ice loading is defined under NESC Rules 250 and 251 as 0.5 inch radial thickness of ice and 4 PSF horizontal wind pressure at 0º Fahrenheit. Stringing tession is at 60º F. 04/02/04 Page 2 of 2 12 0