ICP Test Report Certification Packet Company name : Littelfuse, Inc. Product Series: 3.6 x 10 mm Axial Leaded Fuse Product #: 876xxx Series Issue Date: January 19, 2013 It is hereby certified by Littelfuse, Inc. that there is neither RoHS (EU Directive 2002/95/EC, 2011/65/EU)-restricted substance nor such use, for materials to be used for unit parts, for packing/packaging materials, and for additives and the like in the manufacturing processes. In addition, it is hereby reported to you that the parts and sub-materials, the materials to be used for unit parts, the packing/packaging materials, and the additives and the like in the manufacturing processes, are all composed of the following components. Issued : <Global EHS Engineer> (1) Parts, sub-materials and unit parts This document covers the 3.6 x 10 mm Axial Leaded Fuse, RoHS-Compliant series products manufactured by Littelfuse, Inc. < Raw Materials Used Please see Table 1 (2) The ICP data on all measurable substances Please see appropriate pages as identifed in Table 1 Remarks: Form 585-047 Rev. A 1 2/21/06 Table 1: List of Raw Materials covered by this report Total Parts 1 2 3 4 5 6 Raw Material Part Number 909-444 934-065 425672 497xxx-001 082xxx 692481 Raw Material Description Ceramic Body Cap/ Lead Assay – base and plating Black Ink Sn Plated Wire- Ni42Fe58MCuMSn Ag Plated Cu-Element Solder Wire 2 Page(s) 3-13 14-17 18-26 27-32 33-37 38-43 l\OV'BF.F.q,A TESTREPORT NO.:4002R121008024-2R02 Oate:Oct.1 0,2012 Cuslomer: SuzhouFuHongElectronicIndustriatCo., 16. Addr6s: NO.89 \/ElDU ROAD,WANGTINGTOVIN,XTANGCHENG DISTR|CI SUZHOU.CHINA Repod on the submltted samrl€ said to be sample name: Leadwife coppershell Modol:/ Itefi/Lot Io.: / Matonal:/ Buyen/ Supplier:/, lilanufacturE:/-f . _ - i Samplerecelveddate: Gq 2012 : _08, : t*,tn o"n.o,t.. o".;;,,013 "."r.-,.,,613, 1 ,] i &glirs-Bgsccsgq As specifedby dienl,to determine the L€ad,Cadrium,l,tercury & tiexayabntChrcmium conle in the6ubmitted samptein accodance withDirective 2OO2I95/EC {RoHS). j Testino method: Testingltem Lead(Pb) IEC62321:2008. sectionI cadmium(Cd) IEC62321:2008, s€ction9 (Hg) [,lercury IEC62321r2008, s€ction7 (CrM) Chromium IEC62321:2008,AnnexB Measufing instrument ,MQL rcP-oEs a!gag tcP-oEs rcP-oEs 2 mg/kg 2 mg/kg 0.02mg/kg* lsq j 0.02mg/tg rctursto the MQL olsampleexlractionliquid. Conclu3ion: -\ryhentested as specifiedlhe submiliedsamplecompriedwith th€ requircmentsof commissionD€cisionof 18 Aug 2005 amendingDircctive2002/95/ECnotiliedunderdocum€nt2005/618/EC. ."*FOR FURTHERDETAILS,PLEASEREFERTOT Sign€dior and on behallol ShenzhenAOVTestingTechnology Co., Ltd,Kunshan8ran6h Walbn A?1 ea"arc"a"r, YuanQi, l,lickey LiTingting,Maggie Chemical Test Direclor OrO."*0r44 Technical Di€clor LabManager STIENZIIEN AOVTE$Tl'{GI€CHI!OLOGYCO,.I.TD,KUNSHAN BRANCI] (,10",'ll,,u* l\ov"BF,?sn TESTREPORT NO.:A0O2R12100802+2R02 D a t eO c i . 1 0 , 2 0 1 2 T63l Flow: L ToDetemine/lead, CldmiumContent(Metalsubstrale) lestedbY L7.^otq, Add the digestionsolulionjthe vess€lis heateduntilthesample Coolingthe vessel,fiitei washedand fllledlo the mafKwith distilledwaler. -*".irl,"*J "r,to,"t|, The sampleis digestedin the Addlhe digestion soluUon, close lhemicrowave vessel. micrcwaveoventollowinga specinc progrcm. deoomposilion Coolingthe vessel,frller;washedand filled to the maft wilh dislilled waler. Remove lhe sample, andcool thebeak€rlo roomtemperature, anddo thecolorreaclion -].f---- Testthe samplesolulionand ihe 0.02 mg/kgslandardsolutionby uv-vls. (Plating) nrte,.washedand ______-l l_____*p;-r, f;;-1 "*rn rilledlo$e markwithDlwaler I I ON EANCH ShENZH€N A O VI 6 S T I I { GT ' C N O I O G YC O . . I T D . X U N S H A ' Hotlrne 40a 7008600 /\OV"BF#,HN TESTREPORT NO.iA002R121008024-2R02 O a t e : O c l 1 02 0 1 2 coalingon metals:(Plating) in colorless andcolorcdchromate Hexavalent Chromium Content 5. ToDeiermine r e s t ebd'v : l ) ^, L/A^U,4. ( 5.1Spotlesl lf thelestresultis posiiive, lo ihesampleis considered chromium havehexavalenl Place 1-5 Boiling- water- lf the testreslrlt extracton procedurcshall be us€d to and the 0.02 mg/kg lltherc is intederenceor it is had to decide whetherlhesamplehavethe hexavalent water-enractron 5.2Boilin9Removethe sample,and cool Takethe (50i5)cm2 Heat50 ml ol Dl walerin the samplein the beaker. beak€rto boilinglof 10 min the beakerto rcomtemperalu€, and do the colorrcaolion Sample Doscripilon: Code Sample Desc{iplion Leadwire Plating Unit Code coppershellsubslfate CoppershellPlatng 24 Result RoHSLimit 2-3 N.O Lead{Pb) (Cd) Cadmium mg/l(g 1000 N.D. N.D. N.D. mg/k9 100 N.D. N.D. N.D, N.D. (Hg) Meroury mg/kg 1000 N.D. N.D. N.D, ND. Chromum(Crl'I) mg/K9 1000 Negalive Negalrve Negaliv€ Negative S N € $ Z H E NA O V I : S T I N G T € C N O I O G Y C O ' ' I T D . X U N S I l A NB B A N C I I f l;"')l;** TESTREPORT oare:oct.10,2012 NO.:A0O2R12100802+2R02 -:fh€newRoHSdi€ctive2011/65/EU, Direcliv€ on Jul.21,2011comeinloforce,on Jan.03,2013thsformalimplementation, simultaneously200295/EC ahallbe repeal€d Sp€cimens,whichggqeted to d€temineLead,CadmiumandMercuryconient havebeendissolvedcompletelv. -mg/Kg=ppm ceofC_rl\,I)l if"veiry/y6hetp ttef.li v meresr{.q!.be/rurTr --The iest is bas€don the following maybecannotstandfor the physicaltruth -Photois included ii'iffyiT-'' lhe spot test result is uncertainor *'q:* eachpadis unifom.Theteslrcsult Leadwir€ coppershell "'End of Repod"" SRANCIi CO.,ITDKUNSHAN AOVrlsrr'tc IECNl'lO!OeY sHEI\tZH:ir r.r i35.1J:55i0eo0o Fd.3F1t?55roEr$ hrr ,w.d{.di' Fodrdo 1r.r00 /, Hotlrne I , 400 7008600 Number : TWNC00256916 Test Report Applicant: Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : May 16, 2012 Sample Description: One (1) group of submitted samples said to be : Part Description : Ink Part Number : 425672 Date Sample Received : May 10, 2012 Date Test Started : May 10, 2012 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00256916 Test Conducted (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Polybrominated Biphenyls (PBBs) Monobrominated Biphenyls (MonoBB) Dibrominated Biphenyls (DiBB) Tribrominated Biphenyls (TriBB) Tetrabrominated Biphenyls (TetraBB) Pentabrominated Biphenyls (PentaBB) Hexabrominated Biphenyls (HexaBB) Heptabrominated Biphenyls (HeptaBB) Octabrominated Biphenyls (OctaBB) Nonabrominated Biphenyls (NonaBB) Decabrominated Biphenyl (DecaBB) Polybrominated Diphenyl Ethers (PBDEs) Monobrominated Diphenyl Ethers (MonoBDE) Dibrominated Diphenyl Ethers (DiBDE) Tribrominated Diphenyl Ethers (TriBDE) Tetrabrominated Diphenyl Ethers (TetraBDE) Pentabrominated Diphenyl Ethers (PentaBDE) Hexabrominated Diphenyl Ethers (HexaBDE) Heptabrominated Diphenyl Ethers (HeptaBDE) Octabrominated Diphenyl Ethers (OctaBDE) Nonabrominated Diphenyl Ethers (NonaBDE) Decabrominated Diphenyl Ether (DecaBDE) Halogen Content Fluorine (F) Chlorine (Cl) Bromine (Br) Iodine (I) Result (ppm) Black Paste ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND ND Page 2 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00256916 Test Conducted (Ⅰ) Test Result Summary : Test Item Result (ppm) Black Paste Phthalates Di(2-ethylhexyl) Phthalate (DEHP) Dibutyl Phthalate (DBP) Benzyl Butyl Phthalate (BBP) Others Hexabromocyclododecane (HBCDD) ND ND ND ND Remarks: ppm = Parts per million based on wet weight of tested sample = mg/kg ND = Not detected Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : May 10, 2012 : May 10, 2012 To May 16, 2012 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Polybrominated Biphenyls (PBBs) Polybrominated Diphenyl Ehters (PBDEs) Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 3 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00256916 Test Conducted (Ⅲ) Test Method: Test Item Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Cadmium (Cd) microwave digestion until the tested content samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by Lead (Pb) content microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave Mercury (Hg) digestion until the tested samples are content totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 6+ Chromium VI (Cr ) 1.0:2008 in annex C, by alkaline content digestion and determined by UV-Vis spectrophotometer. With reference to IEC 62321 edition 1.0:2008 in annex A, by solvent Polybrominated extraction and determined by GC-MS and Biphenyls (PBBs) further HPLC-DAD confirmation when necessary. With reference to IEC 62321 edition Polybrominated 1.0:2008 in annex A, by solvent Diphenyl Ethers extraction and determined by GC-MS and (PBDEs) further HPLC-DAD confirmation when necessary. With reference to EN 14582:2007 by Halogen Content calorimetric bomb with oxygen and determined by Ion Chromatograph. With reference to EN 14372: 2004, by Phthalates solvent extraction and determined by GC-MS. With reference to USEPA 3540C, by Hexabromocyclodode solvent extraction and determined by cane (HBCDD) GC-MSD. Reporting Limit 2 ppm 2 ppm 2 ppm 1 ppm 5 ppm 5 ppm 50 ppm 10 ppm 10 ppm Remark: Reporting limit = Quantitation limit of analyte in sample Page 4 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00256916 Test Conducted (Ⅳ) Measurement Flowchart: Test for Cd/Pb/Hg/Chromium (VI)/PBBS/PBDES Contents Reference Standard: IEC 62321 edition 1.0:2008 Sample preparation For non-metal part For metal part Take sample and immerse into Aqua Regia, start to strip plating layer Stop the stripping procedure upon color change completely Take the Aqua solution as plating component and stripped body as substrate component Cd/Pb/Hg Cr Weigh sample and add organic solvent By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water PBBs/PBDEs Polymers / electronics Metal For different material, digest the sample with *1 appropriate acid 6+ Get 50cm2 sample By boiling water extraction *2 Weigh sample and add alkaline solution By Soxhlet extraction or Solvent extraction Definite temp. extraction Cool and filter the extract Analyzed by ICP-OES Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List of Appropriate Acid: Acid Added for Digestion Material Polymers HNO3,HCl,HF,H2O2,H3BO3 Metals HNO3,HCl,HF Electronics HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. Page 5 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00256916 Test Conducted (Ⅳ) Measurement Flowchart: Test for Halogen Content Reference Standard:EN 14582 Sampling/grinding or cutting Add absorbent in a combustion flask & place weighed sample in equipment Fill oxygen into calorimetric bomb Ignite then leave the bomb at room temperature Transfer the absorbent into a volumetric flask Make up with deionized water Analyzed by ion chromatography Page 6 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00256916 Test Conducted (Ⅳ) Measurement Flowchart: Test For Phthalates Contents Reference Method: EN 14372: 2004 Sampling/grinding or cutting Weigh sample and add organic solvent By solvent extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD Page 7 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00256916 Test Conducted (Ⅳ) Measurement Flowchart: Test For Hexabromocyclododecane (HBCDD) Reference Standard:USEPA 3540C Sampling/grinding or cutting Weigh sample and add organic solvent By soxhlet extraction Concentrate the extract and make up with organic solvent Analyzed by GC-MSD End of Report Page 8 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00256916 Test Conducted Photo Page 9 of 9 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Intertek Consumer Goods GmbH · Würzburger Straße 152 · 90766 Fürth · Polyfil AG Gina Gregorio Oberallmendstrasse 20A 6300 Zug / Switzerland Fürth, 2012-12-19 Test report No. FUHL1236938 Testing of a material sample according to the RoHS directive 2011/65/EC Sample description: Ni42Fe58MCuMSn wire; part no. 4500237197; batch 0380.6025 Arrival in lab: 2012-012-04; Period of XRF analysis incl. sample preparation and photo documentation: 2012-12-07 – 2012-12-10 Head of Inorganic Lab: Claudia List Copying this test report is permitted only in agreement with the contracted lab. The test results refer only to the tested item. This report consists of 6 page(s). The test methods signed with * are not listed in the attachment of the accreditation certificate. Conclusion based on tested item Status Test order testing according to the RoHS directive 2011/65/EC ° conform° Please see overview of test results - Test results see next pages - Intertek Consumer Goods GmbH Würzburger Straße 152 90766 Fürth, Germany Tel.: +49 911 74075 0 Fax: +49 911 74075 30 [email protected] Sitz Fürth Amtsgericht Fürth, HRB 5756 USt-IdNr. DE169317871 Geschäftsführer Kay Grönhardt Rainer Mast Durch die DAkkS nach DIN EN ISO/IEC 17025 akkreditiertes Prüflaboratorium Die Akkreditierung gilt für die in der Urkunde aufgeführten Prüfverfahren. Page 2 of 6 page(s) of our test report No. FUHL1236938 dated 2012-12-19 Sample description: Ni42Fe58MCuMSn wire; part no. 4500237197; batch 0380.6025 nM = non Metal M = Metal cM = composite Material List of component parts: Sample No. Part No. 236938 1 Intertek Consumer Goods GmbH Würzburger Straße 152 90766 Fürth, Germany Material Description M Ni42Fe58MCuMSn wire; part no. 4500237197; batch 0380.6025 Tel.: +49 911 74075 0 Fax: +49 911 74075 30 [email protected] Sitz Fürth Amtsgericht Fürth, HRB 5756 Ust-IdNr. DE169317871 Geschäftsführer Kay Grönhardt Rainer Mast Page 3 of 6 page(s) of our test report No. FUHL1236938 dated 2012-12-19 Sample description: Ni42Fe58MCuMSn wire; part no. 4500237197; batch 0380.6025 Comment LOD = Limit of Detection BL OL X σ = = = = Below Limit Over Limit Inconclusive, further test necessary Standard deviation CS = Composite sample Remark: Results were obtained by EDXRF for primary screening. Additional chemical testing using ICP (for Cd, Pb), AAS (for Hg), IC-UC/VIS (for CrVI) and GC/MS (for PBBs/PBDEs) are recommended, if the concentration exceeds the below warning value according to IEC 62321. Element Cd Pb Hg Br Cr Unit mg / kg mg / kg mg / kg mg / kg mg / kg non - metal BL ≤ (70-3σ) < X < (130+3σ) ≤ OL BL ≤ (700-3σ) < X < (1300+3σ) ≤ OL BL ≤ (700-3σ) < X < (1300+3σ) ≤ OL BL ≤ (300-3σ) < X BL ≤ (700-3σ) < X Element Cd Pb Hg Br Cr Unit mg / kg mg / kg mg / kg mg / kg mg / kg composite material LOD < X < (150+3σ) ≤ OL BL ≤ (500-3σ) < X < (1500+3σ) ≤ OL BL ≤ (500-3σ) < X < (1500+3σ) ≤ OL BL ≤ (250-3σ) < X BL ≤ (500-3σ) < X Intertek Consumer Goods GmbH Würzburger Straße 152 90766 Fürth, Germany Tel.: +49 911 74075 0 Fax: +49 911 74075 30 [email protected] metal BL ≤ (70-3σ) < X < (130+3σ) ≤ OL BL ≤ (700-3σ) < X < (1300+3σ) ≤ OL BL ≤ (700-3σ) < X < (1300+3σ) ≤ OL -BL ≤ (700-3σ) < X Sitz Fürth Amtsgericht Fürth, HRB 5756 Ust-IdNr. DE169317871 Geschäftsführer Kay Grönhardt Rainer Mast Page 4 of 6 page(s) of our test report No. FUHL1236938 dated 2012-12-19 Sample description: Ni42Fe58MCuMSn wire; part no. 4500237197; batch 0380.6025 1. XRF screening Method: Sample No. 236938 XRF according to IEC 62321:2008* Part No. 1 Pb Hg Cd Crtotal Br Status BL BL BL BL -- conform Comment: Elements Lead (Pb) Mercury (Hg) Cadmium (Cd) Chromium VI (Cr VI) Polybrominated Biphenyle (PBBs) Polybrominated Diphenyl ether (PBDEs) RoHS-limit value 1000 mg/kg 1000 mg/kg 100 mg/kg 1000 mg/kg 1000 mg/kg 1000 mg/kg - Flow charts see next page(s) - Intertek Consumer Goods GmbH Würzburger Straße 152 90766 Fürth, Germany Tel.: +49 911 74075 0 Fax: +49 911 74075 30 [email protected] Sitz Fürth Amtsgericht Fürth, HRB 5756 Ust-IdNr. DE169317871 Geschäftsführer Kay Grönhardt Rainer Mast Test procedure Page 5 of 6 page(s) YES non-destructive sample preparation sample uniform ? screening procedure by XRF YES NO samples mechanical sample preparation screening by XRF ? metallic materials, pass meets limits ? YES NO YES fail further testing ? NO NO mechanical sample preparation polymer materials, entity based conforming sample chemical test procedure (verification) various methods (please see verification test procedure below) entity based non conforming sample pass YES electronics (PCB / component) entity based conforming sample meets limits ? fail NO Intertek Consumer Goods GmbH Würzburger Straße 152 90766 Fürth, Germany Tel.: +49 911 74075 0 Fax: +49 911 74075 30 [email protected] Sitz Fürth Amtsgericht Fürth, HRB 5756 Ust-IdNr. DE169317871 Geschäftsführer Kay Grönhardt Rainer Mast entity based non conforming sample Verification test procedure Page 6 of 6 page(s) Sample Preparation Sample Measurement Acid digestion with microwave / hotplate Sample solvent extraction Filtration Concentration/ Dilution of extraction solution Solution Cr6+ PBBs/PBDEs Pb/Cd/Hg Residue Filtration Total digestion GC/MS DATA Non-metallic material Alkaline extraction Adding extraction solution Metallic material Positive Negative Boiling water extraction Alkaline extraction Heating to 90~95°C for extraction Adding 1,5diphenylcarbazide for color development Filtration and pH adjustment ICP-OES/AAS A red color indicates the presence of Cr6+ If necessary, confirm with UV-VIS or IC-UV/VIS Adding 1,5diphenylcarbazide for color development DATA DATA UV-VIS or IC-UV/VIS DATA Intertek Consumer Goods GmbH Würzburger Straße 152 90766 Fürth, Germany Tel.: +49 911 74075 0 Fax: +49 911 74075 30 [email protected] Sitz Fürth Amtsgericht Fürth, HRB 5756 Ust-IdNr. DE169317871 Spot test Geschäftsführer Kay Grönhardt Rainer Mast Test Report Applicant: Number : TWNC00249179 Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Mar 28, 2012 Sample Description: One (1) group of submitted samples said to be : Part Description : Silver plated Wire Part Number : DRAGxxx Date Sample Received : Mar 22, 2012 Date Test Started : Mar 22, 2012 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director This report shall not be reproduced except in full, without the written approval of the laboratory. Page 1 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00249179 Test Conducted (Ⅰ) Test Result Summary : Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (mg/kg with 50cm2) Result (ppm) Submitted Samples ND ND ND Negative (< 0.02) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of Test. Responsibility of Chemist : Irene Chiou / Kevin Liu / Cathy Chen Date Sample Received Test Period : Mar 22, 2012 : Mar 22, 2012 To Mar 27, 2012 (Ⅱ) RoHS Requirement: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from 2002/95/EC and amendment 2005/618/EC for homogeneous material. Page 2 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00249179 Test Conducted (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis Spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 0.02 mg/kg with 50cm2 Remark: Reporting limit = Quantitation limit of analyte in sample Page 3 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00249179 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Cr Polymers / Electronics Metal For different material, digest the sample with *1 appropriate acid By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water 6+ *2 Weigh sample and add alkaline solution Get 50cm2 sample Definite temp. extraction Boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS Remarks: *1: List Of Appropriate Acid: Material Polymers Metals Electronics Acid Added For Digestion HNO3,HCl,HF,H2O2,H3BO3 HNO3,HCl,HF HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report Page 4 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Number : TWNC00249179 Test Conducted Photo Page 5 of 5 Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 114, Taiwan, R.O.C. 全國公證檢驗股份有限公司 114 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2400.6602-2401 Test Report Applicant: Number : TWNC00289673 Littelfuse Philippines Inc. LIMA Technology Center, Lipa City, Malvar, Batangas Date : Dec 13, 2012 Sample Description: One (1) group of submitted samples said to be : Part Description : Solder Part Number : 692481 Date Sample Received : Dec 06, 2012 Date Test Started : Dec 07, 2012 Test Conducted : As requested by the applicant, for details please refer to attached pages. Authorized By: On Behalf Of Intertek Testing Services Taiwan Limited K. Y. Liang Director *THJ0289673* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 1 of 6 Number : TWNC00289673 Test Conducted (Ⅰ) Test Result Summary : Result (ppm) Silvery metal Test Item Heavy Metal Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content (mg/kg with 50cm2) ND 260 ND Negative (< 0.02) Remarks: ppm = Parts per million based on weight of tested sample = mg/kg ND = Not detected < = Less than mg/kg with 50cm2 = milligram per kilogram with 50 square centimetre Negative = A negative test result indicated positive observation was not found at the time of Test. Responsibility of Chemist : Irene Chiou / Kevin Liu Date Sample Received Test Period : Dec 06, 2012 : Dec 07, 2012 To Dec 12, 2012 (Ⅱ) RoHS Limits: Restricted Substances Cadmium (Cd) Content Lead (Pb) Content Mercury (Hg) Content Chromium VI (Cr6+) Content Limits 0.01% (100ppm) 0.1% (1000ppm) 0.1% (1000ppm) 0.1% (1000ppm) The above limits were quoted from Annex II of 2011/65/EU for homogeneous material. *THJ0289673* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 2 of 6 Number : TWNC00289673 Test Conducted (Ⅲ) Test Method: Test Item Cadmium (Cd) content Lead (Pb) content Mercury (Hg) content Chromium VI (Cr6+) content Test Method With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 8/9/10, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in clause 7, by microwave digestion until the tested samples are totally dissolved and determined by ICP-OES. With reference to IEC 62321 edition 1.0:2008 in annex B, by boiling water extraction and determined by UV-Vis Spectrophotometer. Reporting Limit 2 ppm 2 ppm 2 ppm 0.02 mg/kg with 50cm2 Remark: Reporting limit = Quantitation limit of analyte in sample *THJ0289673* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 3 of 6 Number : TWNC00289673 Test Conducted (Ⅳ) Measurement Flowchart: Test For Cd/Pb/Hg/Chromium (VI) Reference Standard:IEC 62321 edition 1.0:2008 Sampling/grinding or cutting Cd/Pb/Hg Cr 6+ Polymers / Electronics Metal For different material, digest the sample with *1 appropriate acid By spot test Negative Confirm the tested samples are totally dissolved Make up with deionized water *2 Weigh sample and add alkaline solution Get 50cm2 sample Definite temp. extraction Boiling water extraction Cool and filter the extract Analyzed by ICP-OES Make up with deionized water and add diphenylcarbazide solution Analyzed by UV-VIS *THJ0289673* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 4 of 6 Number : TWNC00289673 Test Conducted Remarks: *1: List of Appropriate Acid: Material Acid Added for Digestion Polymers HNO3,HCl,HF,H2O2,H3BO3 Metals HNO3,HCl,HF Electronics HNO3,HCl,H2O2,HBF4 *2: If the result of spot test is positive, Chromium VI would be determined as detected. End of Report This report is made solely on the basis of your instructions and/or information and materials supplied by you. It is not intended to be a recommendation for any particular course of action. Intertek does not accept a duty of care or any other responsibility to any person other than the Client in respect of this report and only accepts liability to the Client insofar as is expressly contained in the terms and conditions governing Intertek's provision of services to you. Intertek makes no warranties or representations either express or implied with respect to this report save as provided for in those terms and conditions. We have aimed to conduct the Review on a diligent and careful basis and we do not accept any liability to you for any loss arising out of or in connection with this report, in contract, tort, by statute or otherwise, except in the event of our gross negligence or wilful misconduct. *THJ0289673* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 5 of 6 Number : TWNC00289673 Test Conducted Photo *THJ0289673* Intertek Testing Services Taiwan Ltd. 8F., No. 423, Ruiguang Rd., Neihu District, Taipei 11492, Taiwan, R.O.C. 全國公證檢驗股份有限公司 11492 台北市內湖區瑞光路 423 號 8 樓 Tel: (+886-2) 6602-2888.2797-8885 Fax: (+886-2) 6602-2410 Page 6 of 6