data sheet - family

Magnetic sensors
MTRM 16
Hall sensors
29
0
-0,1
+0,15
0
ø 26
3,3
ø 15,9
7,3
5,5
ø 9
60
42
16
3
x5
2
H1
ø 20
7
ø 22 ±0,1
sample drawing
33
10
29
0
-0,1
93
general data
sample picture
version
full metal
sensor type
differential hall sensor
gear width
> 10 mm
gear material
ferromagnetic
gear shape
involute gear (DIN867)
electrical data
switching frequency range
2 ... 20 kHz
voltage supply range +Vs
8 ... 28 VDC
current consumption max. (no load)
20 mA
output A
push-pull
output B
push-pull
output current
< 30 mA
voltage drop Vd
< 5 VDC
short circuit protection
yes
reverse polarity protection
yes, Vs to GND
insulation resistance (at 500 VDC)
> 100 MΩ
leakage current (at 500 Veff AC)
< 0,5 mA
mechanical data
type
cylindrical, with flange
housing material
brass nickel plated
dimension
16 mm
housing length
93 mm
installation aid
pin hole
connection types
cable Radox, 2 m
front of sensor durable against pressure
20 bar
ambient conditions
operating temperature
-40 ... +120 °C
protection class (sensing face)
IP 68
protection class (sensor)
IP 67
1
www.baumer.com
2/6/2015
Magnetic sensors
MTRM 16
Hall sensors
order reference
working distance max.
min. gear size
MTRM 16G2524/M100
1,0 mm (module 1)
module 1
MTRM 16G2524/M150
1,6 mm (module 1,5)
module 1,5
MTRM 16G2524/M200
2 mm (module 2)
module 2
MTRM 16G2524/M250
2,2 mm (module 2,5)
module 2,5
MTRM 16G2524/M300
2,5 mm (module 3)
module 3
2
www.baumer.com
2/6/2015