PBSP-96Z Series

RAILWAY CONVERTERS
PBSP-96Z Series
9 6 V D C , 3 5 0 0 W AT T S R A I LW AY D C / A C I N V E R T E R
Features
•
•
•
•
Halogen free low smoke Radox cabling.
ELCB on output, high gauge earthing system.
High temperature operation with derating.
96Vdc input, 240Vac, 50Hz, 3.5KVA output.
SPECIFICATIONS
INPUT
OPERATING
Voltage
76-125Vdc
Efficiency
90%–95% load dependent.
Current
40mA standby, 44A (96Vdc input), 125A max.
Isolation
Under voltage cut-out
76Vdc.
Input – Output: 4250VAC
Input – Ground: 1700VAC
Output – Ground: 2250VAC
Under voltage re-set
92Vdc.
Over voltage cut-out
125Vdc.
Over voltage re-set
122Vdc.
Input protection
Via 10kA MCB as per AS3111
OUTPUT
Voltage
240Vac ±5%
Frequency
50Hz ±5%
Total harmonic distortion
3%
Surge power
250% max.
Output overload and short Shutdown, auto restart after 60 secs.
circuit protection
Output protection
Via 20A MCB / RCD as per AS3111 / AS3190.
Output neutral connected to inverter chassis
earth on inverter side of MCB / RCD.
Over temperature
Shutdown, auto restart.
protection
ENVIRONMENTAL
Operating temperature
Cooling
0°C to 50°C at full load. Derate to 65°C at
reduced duty cycle.
Internal thermostatically controlled fan.
Shock and vibration
Unit has been mechanically strengthened.
Relative Humidity
95% non-condensing
STANDARDS
C-Tick
Designed to meet AS/NZS CISPR11:
/EN50121-3-2 limits
MECHANICAL
Dimensions
490x300x235mm
Weight
38kgs.
Enclosure
Powder coated aluminium.
Wiring
All internal wiring uses Radox 125 halogen
free low smoke cable.
Mounting
Suitable for vertical or horizontal mounting.
DC input connector
MS3102-E28-22P-F80 Mil grade connector.
AC output connector
MS3102-R18-10S-F80 Mil grade connector.
Please refer to PBSP 740 spec for mechanical drawings.
474
Doc. No. PBC9 Rev.C 28-4-11