RAILWAY CONVERTERS PBSP-96Z Series 9 6 V D C , 3 5 0 0 W AT T S R A I LW AY D C / A C I N V E R T E R Features • • • • Halogen free low smoke Radox cabling. ELCB on output, high gauge earthing system. High temperature operation with derating. 96Vdc input, 240Vac, 50Hz, 3.5KVA output. SPECIFICATIONS INPUT OPERATING Voltage 76-125Vdc Efficiency 90%–95% load dependent. Current 40mA standby, 44A (96Vdc input), 125A max. Isolation Under voltage cut-out 76Vdc. Input – Output: 4250VAC Input – Ground: 1700VAC Output – Ground: 2250VAC Under voltage re-set 92Vdc. Over voltage cut-out 125Vdc. Over voltage re-set 122Vdc. Input protection Via 10kA MCB as per AS3111 OUTPUT Voltage 240Vac ±5% Frequency 50Hz ±5% Total harmonic distortion 3% Surge power 250% max. Output overload and short Shutdown, auto restart after 60 secs. circuit protection Output protection Via 20A MCB / RCD as per AS3111 / AS3190. Output neutral connected to inverter chassis earth on inverter side of MCB / RCD. Over temperature Shutdown, auto restart. protection ENVIRONMENTAL Operating temperature Cooling 0°C to 50°C at full load. Derate to 65°C at reduced duty cycle. Internal thermostatically controlled fan. Shock and vibration Unit has been mechanically strengthened. Relative Humidity 95% non-condensing STANDARDS C-Tick Designed to meet AS/NZS CISPR11: /EN50121-3-2 limits MECHANICAL Dimensions 490x300x235mm Weight 38kgs. Enclosure Powder coated aluminium. Wiring All internal wiring uses Radox 125 halogen free low smoke cable. Mounting Suitable for vertical or horizontal mounting. DC input connector MS3102-E28-22P-F80 Mil grade connector. AC output connector MS3102-R18-10S-F80 Mil grade connector. Please refer to PBSP 740 spec for mechanical drawings. 474 Doc. No. PBC9 Rev.C 28-4-11