POWERBOX PBSP-740

RAILWAYS
PBSP 740 Series
7 2 V D C , 4 0 0 0 W AT T S R A I LW AY D C / A C I N V E R T E R
Features
• High surge rating of 12kW.
• Halogen free low smoke Radox cabling.
• Earth leakage breaker on output.
• Strengthened against shock & vibration.
• Input spike & burst protection.
Specifications
STANDARDS AND APPROVALS
INPUT
Voltage
60-84Vdc
Current
40mA standby, 60A (74Vdc input), 160A max.
Under voltage cut-out
59Vdc.
Under voltage re-set
71Vdc.
Over voltage cut-out
EMC
EN50121-3-2:2000.
C-Tick
AS/NZS2064:1997 Group 1 Class A
MECHANICAL
Dimensions
490x300x235mm
90Vdc.
Weight
38kgs.
Over voltage re-set
87Vdc.
Enclosure
Powder coated aluminium chassis.
Input protection
100A, AS3111, 10kA MCB.
Wiring
All internal wiring uses Radox 125 halogen free
low smoke cable.
Mounting
Suitable for vertical or horizontal mounting.
DC input connector
MS3102 R28-22P F80 six crimp pin chassis
receptacle.
DC mating connector
MS3108 E28-22SF80 right angle six crimp socket
plug with strain relief. Supplied with unit
OUTPUT
Voltage
240Vac ±5%
Frequency
50Hz ±1%
Total harmonic distortion
3%
Output power
4kW continuous.
Surge power
5kW, 30min; 12kW, 3sec.
Output overload and short
circuit protection
Automatic shutdown, auto restart after 60 secs.
Output protection
Via 20A MCB / RCD as per AS3111 /
AS3190.Output neutral connected to inverter
chassis earth on inverter side of MCB / RCD.
OUTPUT CONNECTOR (PBSP-740-D Variant)
Over temperature protection Shutdown, auto-restart.
OPERATING
AC output connector
MS3102 R1810S F80. Four crimp socket chassis
receptacle.
AC mating connector
MS3106 R1810P F80. Four crimp pin plug with
strain relief supplied with the unit.
OUTPUT CONNECTOR (PBSP-740-G Variant)
Efficiency
90%–95% load dependent.
AC output connector
Three Wilco WIBM110-LE
Isolation
Input – Output: 4250VAC
Input – Ground: 1700VAC
Output – Ground: 2250VAC
Terminations
Single phase 10A 3 flat IP56 insulated socket
outlets.
ENVIRONMENTAL
Operating temperature
0°C to 50°C ambient. Derate to 65°C at reduced
duty cycle.
Cooling
Internal thermostatically controlled fan.
Shock
4G ±20% longitudinally
Vibration
Resonant search:
20-2.2mm double amplitude (1-9Hz)
2.2-0.8mm double amplitude (10-50Hz)
Endurance:
3 hours per axis (X,Y,Z) at 50Hz 0.8mm double
amplitude.
Relative Humidity
95% non-condensing
Your dependable power partner – www.powerbox.com.au
399
RAILWAYS
PBSP 740 Series
7 2 V D C , 4 0 0 0 W AT T S R A I LW AY D C / A C I N V E R T E R S
D - Variant
G - Variant
400