Space Level Flow HR500S Axial and Surface Mount

2010 Catalog
High-Rel Discrete Semiconductors
Assembly Products
Semtech Space Level Flow
HR500S Axial and Surface Mount Packages
W W W .SE MTE C H .C O M
2010 Catalog
Semtech Space Level Flow
HR500S Axial and Surface Mount Packages
Table of Contents
HR500S (Axial Lead Package)
JANTXV quality level­------------------------------------------- 4
100% Screening ­-------------------------------------------5
Group “A” same as Mil-PRF-19500­------------------------------------------- 8
Group “B” same as Mil-PRF-19500 ­-------------------------------------------9
HR500S (Surface Mount Package)
JANTXV quality level ­------------------------------------------- 12
100% Screening­------------------------------------------- 13
Group “A” same as Mil-PRF-19500 ­------------------------------------------- 14
W W W .SE MTE C H .C OM
-3-
HR500S (Axial Lead Package)
HR500S (Axial Lead Package)
The platform device for this flow would be of JANTXV
quality level
Test
Operation
MIL STD
Reference
Document
1
Fab
Traceability
2
Internal Visual
750/2074
3
Visual &
Mechanical
750/2071
4
Electrical Sort
5
Scope Display
Conditions and/or Description of
Operation
(TA =+ 25C Unless Otherwise
Specified)
Lot form prior to assembly from a
single wafer fabrication lot
The devices shall be examined for:
Workmanship Materials, Design and
Construction
Electrical sort to Semtech internal
specifications
750/4023
BV > xxx, trace to be as specified
W W W .SE MTE C H .C OM
Page 1
-4-
HR500S (Axial Lead Package)
HR500S (Axial Lead Package)
100% SCREENING
Test
1
2
Operation
High
Temperature
Storage
Thermal
Cycling
MIL STD
Reference
Document
Conditions and/or Description of
Operation
(TA =+ 25C Unless Otherwise Specified)
750/1031
TA = 175 ºC, Time = 24 Hours
750/1051
Condition C,
Temp. extremes : TA(low) = -55ºC
TA (high) = 175ºC
Time: Extreme = 15min
Number of cycles = 20
3
Thermal
Impedance
4
Thermal
Normalization
750/3101
Thermal distribution determined and
“flyers” removed
750/4016
5
Electrical
GNG
750/4011
750/4021
6
7
VF1, < xxx Vdc, If1 = y Adc (pulse as
specified)
VF2, < xxx Vdc, If2 = y Adc (pulse as
specified)
VBR ≥xxx V dc, Ibv=yyy μA
Ir distribution determined and “flyers”
removed
Serialize
Maintain Individual Identity through
HTRB and Burn-in.
Maintaining serialization through
packaging is an available option
Pre HTRB
Elect
750/4011
750/4021
9
IR <xμA dc, VR = xxx Vdc
Ir
Normalization
750/4016
8
ZθJX = As determined by Group E
analysis
High
Temperature
Reverse Bias
750/1038
IR < Statistical limit VR = xxx Vdc
VF1, < xxx Vdc, If1 = y Adc (pulse as
specified)
VF2, < xxx Vdc, If2 = yy Adc (pulse as
specified)
VBR ≥xxx V dc, Ibv=yyy μA
Condition A, Operated for 48 Hours
min.
TA = 150ºC, VR = 80% of rated VR
W W W .SE MTE C H .C OM
Page 2
-5-
HR500S (Axial Lead Package)
HR500S (Axial Lead Package)
100% SCREENING, continued
Test
Operation
MIL STD
Reference
Document
750/4016
10
Post HTRB
Elect
750/4011
750/4021
11
Post HTRB
Elect deltas
12
PDA
13
Power
Burn-In
750/4016
750/4011
14
(TA=+ 25C Unless Otherwise Specified)
IR <xμA dc, VR = xxx Vdc
VF1, < xxx Vdc, If1 = y Adc (pulse as
specified)
VF2, < xxx Vdc, If2 = y Adc (pulse as
specified)
VBR ≥xxx V dc, Ibv=yyy μA
Delta IR = ± yyy nAdc or 100% of pre
HTRB reading, whichever is greater.
Delta VF± xxx Vdc of pre HTRB reading
The total number of devices failing < 5%
750/1038
750/4016
Post
Burn-in
Elect
Conditions and/or Description of
Operation
750/4011
Condition B, Operated for 240 hours min.
Ta = 55C max, Vr = RATED Vdc, Io =
RATED
IR <xμA dc, VR = xxx Vdc
VF1, < xxx Vdc, If1 = y Adc (pulse as
specified)
VF2, < xxx Vdc, If2 = y Adc (pulse as
specified)
750/4021
VBR ≥xxx V dc, Ibv=yyy μA
750/4016
Delta IR = ± yyy nAdc or 100% of pre
Burn-In reading, whichever is greater.
Delta VF± xxx Vdc of pre Burn-In reading
15
Post
Burn-in
Elect deltas
16
PDA
The total number of devices failing < 5%
17
Combined
PDA
< 10%
750/4011
Page 3
Semtech Corporation 200 Flynn Road Camarillo, CA 93012
W W W .SE MTE C H .C OM
-6-
HR500S (Axial Lead Package)
HR500S (Axial Lead Package)
100% SCREENING, continued
Test
Operation
MIL STD
Reference
Document
18
Scope Display
750/4023
19
Hot Solder Dip
20
Hermetic Seal
21
Body
coat/band/label
22
Visual &
Mechanical
Electricals
(TA =+ 25C Unless Otherwise Specified)
BV > xxx V, trace to be as specified
Serialization not maintained
750/2068
Use 2068 for opaque glass body
750/1071
Use 2071 for clear glass body
750/2071
The devices shall be examined for;
Workmanship Materials, Design and
Construction.
750/4016
23
Conditions and/or Description of
Operation
750/4011
IR <xμA dc, VR = xxx Vdc
VF1, < xxx Vdc, If1 = y Adc (pulse as
specified)
VF2, < xxx Vdc, If2 = y Adc (pulse as
specified)
750/4021
VBR ≥xxx V dc, Ibv=yyy μA
750/4023
BV > xxx V, trace to be as specified
Optional X-Ray
750/2076
2 Views, Maintain Identity
Optional IR Hot
750/4016
Optional TRR
750/4031
Optional CAP
750/4001
18
Scope Display
24
Pack
W W W .SE MTE C H .C OM
Page 4
-7-
HR500S (Axial Lead Package)
HR500S (Axial Lead Package)
GROUP “A” same as Mil-PRF-19500
Sub
Group
1
(15/0)
2
(116/0)
Operation
Visual &
Mechanical
Electrical (Static)
R&R
MIL STD
Reference
Document
Conditions and/or Description of Operation
(TA =+ 25C Unless Otherwise Specified)
750/2071
The devices shall be examined for:
Workmanship, Materials Design, and Construction
750/4016
IR
750/4011
VF
750/4021
VBR
750/3101
ZθJX
TA= +/- zzzC
3
(116/0)
750/4016
IR
750/4011
VF
750/4021
VBR
750/3101
ZθJX
Scope
750/4023
BV
Trr
750/4031
Trr
Capacitance
750/4001
Capacitance
Forward Recovery
Voltage
750/4026
Vfr
750/4026
tfr
Electrical (Static)
R&R
Electrical
(Dynamic)
R&R
4
(116/0)
Forward Recovery
Time
5
6
(22/0)
N/A
Surge Current
750/4066
Page 5
Semtech Corporation 200 Flynn Road Camarillo, CA 93012
W W W .SE MTE C H .C OM
-8-
HR500S (Axial Lead Package)
HR500S (Axial Lead Package)
GROUP “B” same as Mil-PRF-19500
Sub Group
1
(22/0)
2
(15/0)
Operation
Physical DIM
MIL STD
Reference
Document
750/2066
Conditions and/or Description of Operation
(TA =+ 25C Unless Otherwise Specified)
Per Device Outline
Steam Aging Required, Solder Temp = +245+ 5 C
Flux = Type ”R”, Dwell = 5 Seconds + ½ second.
Visual Magnification = 10X > 95% Coverage
Solderability
750/2026
Resistance to
Solvents
750/1022
All areas of the diode body where marking has
applied shall be brushed. Mark to remained legible
at < 3X magnification
750/1056
Test condition A, 25 cycles, dwell > 2 minutes
0 C, +2 C, -10 C / 100 C + 10 C, -2 C
Alcohol + DI Water / Boiling D.I. Water
Transfer time 10< seconds
Thermal Shock
Temp Cycling
750/1051
Condition C,
Temp. extremes : TA(low) = -55ºC+0, -10ºC
TA (high) = 175ºC
Time: Extreme = 15 minutes (min)
Number of cycles = 100
3
(22/0)
Surge Current
750/4066
Hermetic Seal
750/2068
Use 2068 for opaque glass body
(gross leak)
Electrical
DE-CAP
Internal Visual
(6 Devices)
750/4016
IR
750/4011
VF
750/4021
VBR
750/2075
Design Verification
Page 6
Semtech Corporation 200 Flynn Road Camarillo, CA 93012
W W W .SE MTE C H .C OM
-9-
HR500S
(Axial (Axial
Lead Package)
HR500S
Lead Package)
GROUP “B”, continued
Sub
Group
Operation
Pre Electrical
Intermittent Op
Life
4
(22/0)
Electrical
Deltas
Pre Electrical
Operation Life
5
(22/0)
Electrical
Deltas
MIL STD
Reference
Document
Conditions and/or Description of Operation
(TA =+ 25C Unless Otherwise Specified)
750/4016
IR
750/4011
VF
750/1037
2000 cycles condition D
750/4016
IR
750/4011
VF
750/4021
VBR
750/4016
750/4011
Delta IR = ± yyy nAdc or 100% of pre Burn-In
reading, whichever is greater.
Delta VF± xxx Vdc of pre Burn-In reading
750/4016
IR
750/4011
VF
750/1027
Bias as specified. Tj = 175ºC T=1000hrs min.
Post test per A2
750/4016
IR
750/4011
VF
750/4021
VBR
750/3101
ZθJX
750/4016
Delta IR = ± yyy nAdc or 100% of pre Burn-In
reading, whichever is greater.
Delta VF± xxx Vdc of pre Burn-In reading
750/4011
Page 7
Semtech Corporation 200 Flynn Road Camarillo, CA 93012
Phone: 805-498-2111 Web: www.semtech.com
W W W .SE MTE C H .C OM
- 10 -
HR500S (Axial Lead Package)
HR500S (Axial Lead Package)
GROUP “B”, continued
6
(22/0)
Thermal
Resistance
Pre Electrical
High-temperature
Life
7
(32/0)
Electrical
RθJL
750/4016
IR
750/4011
VF
750/1032
340 hours minimum TA = TSTG(max)
750/4016
IR
750/4011
VF
750/4021
VBR
750/4016
Deltas
750/4011
Delta IR = ± yyy nAdc or 100% of pre Burn-In
reading, whichever is greater.
Delta VF± xxx Vdc of pre Burn-In reading
PRP
750/4065
Prsm
750/4016
IR
750/4011
VF
750/4021
VBR
8
(10/0)
750/4081
Electrical
Page 8
Semtech Corporation 200 Flynn Road Camarillo, CA 93012
W W W .SE MTE C H .C OM
- 11 -
HR500S (Surface Mount Package)
HR500S (Surface Mount Package)
The platform device for this flow would be of JANTXV
quality level
Test
Operation
MIL STD
Reference
Document
1
Fab
Traceability
2
Internal Visual
750/2074
3
Visual &
Mechanical
750/2071
4
Electrical Sort
5
Cathode Band
6
Lead Cut Off
7
End Tab
Assembly
and Reflow
8
Visual &
Mechanical
Lot form prior to assembly from a
single wafer fabrication lot
10
Page 1
Electrical GNG
Scope Display
The devices shall be examined for:
Workmanship Materials, Design and
Construction
Electrical sort to Semtech internal
specifications
750/2071
750/4016
9
Conditions and/or Description of
Operation
(TA =+ 25C Unless Otherwise
Specified)
750/4011
The devices shall be examined for:
Workmanship Materials, Design and
Construction
IR <xμA dc, VR = xxx Vdc
VF1, < xxx Vdc, If1 = y Adc
(pulse as specified)
VF2, < xxx Vdc, If2 = y Adc
pulse as specified)
750/4021
VBR ≥xxx V dc, Ibv=yyy μA
750/4023
BV > xxxV, trace to be as specified
Semtech Corporation 200 Flynn Road Camarillo, CA 93012
W W W .SE MTE C H .C OM
- 12 -
HR500S (Surface Mount Package)
HR500S (Surface Mount Package)
100% SCREENING
Test
Operation
MIL STD
Reference
Document
1
High
Temperature
Storage
750/1031
TA = xxx ºC, Time = 24 Hours
750/1051
Condition C,
Temp. extremes : TA(low) = -55ºC
TA (high) = 175ºC
2
Thermal
Cycling
Conditions and/or Description of
Operation
(TA =+ 25C Unless Otherwise Specified)
Time: Extreme = 15min
Number of cycles = 20
3
Thermal
Impedance
4
Thermal
Normalization
5
Hermetic Seal
6
Electrical
GNG
750/3101
Thermal distribution determined and
“flyers” removed
750/2068
Use 2068 for opaque glass body
750/1071
Use 1071 for clear glass body
750/4016
IR <xμA dc, VR = xxx Vdc
750/4011
750/4021
7
8
ZθJX = As determined by Group E
analysis
VF1, < xxx Vdc, If1 = y Adc
(pulse as specified)
VF2, < xxx Vdc, If2 = y Adc
(pulse as specified)
VBR ≥xxx V dc, Ibv=yyy μA
Ir
Normalization
Ir distribution determined and “flyers”
removed
Serialize
Maintain Individual Identity through
HTRB and Burn-in.
Maintaining serialization through
packaging is an available option
W W W .SE MTE C H .C OM
- 13 -
HR500S (Surface Mount Package)
HR500S (Surface Mount Package)
100% SCREENING, continued
Test
9
Operation
Pre HTRB
Elect
MIL STD
Reference
Document
750/4016
750/4011
750/4021
10
11
High
Temperature
Reverse
Bias
Post HTRB
Elect
Post HTRB
Elect Deltas
13
PDA
(TA =+ 25C Unless Otherwise Specified)
IR < Statistical limit VR = xxx Vdc
VF1, < xxx Vdc, If1 = y Adc
(pulse as specified)
VF2, < xxx Vdc, If2 = yy Adc
(pulse as specified)
VBR ≥xxx V dc, Ibv=yyy μA
750/1038
Condition A, Operated for 48 Hours min.
TA = 150ºC, VR = 80% of rated VR
750/4016
IR <xμA dc, VR = xxx Vdc
750/4011
750/4021
12
Conditions and/or Description of
Operation
750/4016
750/4011
VF1, < xxx Vdc, If1 = y Adc (pulse as
specified)
VF2, < xxx Vdc, If2 = y Adc (pulse as
specified)
VBR ≥xxx V dc, Ibv=yyy μA
Delta IR = ± yyy nAdc or 100% of pre
HTRB reading, whichever is greater.
Delta VF± xxx Vdc of pre HTRB reading
The total number of devices failing < 5%
W W W .SE MTE C H .C OM
- 14 -
HR500S (Surface Mount Package)
HR500S (Surface Mount Package)
100% SCREENING, continued
Test
14
15
MIL STD
Reference
Document
Conditions and/or Description of
Operation
Power
Burn-in
750/1038
Condition B, Operated for 240 hours min.
Post
Burn-in
Elect
750/4016
Operation
Ta = 55C max, Vr = RATED Vdc, Io =
RATED
750/4011
750/4021
16
Post
Burn-in
Elect deltas
(TA =+ 25C Unless Otherwise Specified)
750/4016
750/4011
IR <xμA dc, VR = xxx Vdc
VF1, < xxx Vdc, If1 = y Adc
(pulse as specified)
VF2, < xxx Vdc, If2 = y Adc
(pulse as specified)
VBR ≥xxx V dc, Ibv=yyy μA
Delta IR = ± yyy nAdc or 100% of pre
HTRB reading, whichever is greater.
Delta VF± xxx Vdc of pre HTRB reading
17
PDA
The total number of devices failing < 5%
18
Combined
PDA
< 10%
20
Scope
Display
21
Pack
22
Optional
X-Ray
750/2076
23
Optional IR
Hot
750/4016
24
Optional
TRR
750/4031
25
Optional
CAP
750/4001
750/4023
BV > xxx V, trace to be as specified
Maintain part identity from Burn-in
(Optional)
2 Views, Maintain Identity
IR< yyyμA dc, Vr = xxx Vdc, TA = +zzz C
Trr < xxns, If = yA, Ir = yyA, Irec =yyyA
C< xxpf, Vr = yyV, f=1Mhz
W W W .SE MTE C H .C OM
Page 4
- 15 -
HR500S (Surface Mount Package)
HR500S (Surface Mount Package)
GROUP “A” same as Mil-PRF-19500
Sub
Group
1
(15/0)
2
(116/0)
Operation
Visual &
Mechanical
Electrical (Static)
R&R
MIL STD
Reference
Document
750/2071
The devices shall be examined for; Workmanship,
Materials Design, and Construction
750/4016
IR <xμA dc, VR = xxx Vdc
750/4011
VF1, < xxx Vdc, If1 = y Adc (pulse as specified)
VF2, < xxx Vdc, If2 = y Adc (pulse as specified)
750/4021
VBR ≥xxx V dc, Ibv=yyy μA
750/3101
ZθJX = As determined by Group E analysis
750/4016
3
(116/0)
Electrical (Static)
R&R
Conditions and/or Description of Operation
(TA =+ 25C Unless Otherwise Specified)
750/4011
750/4011
750/4021
Ta = +zzzºC
IR < yyyμ Adc, VR = xxxVdc
VF6, < xxx Vdc, If = yy Adc (pulse as specified)
Ta = -zzzºC
VF, < xxx Vdc, If = 1yy Adc (pulse as specified)
VBR ≥xxx V dc, Ibv=yyy μA
Electrical
(Dynamic)
R&R
4
(116/0)
Scope
750/4023
BV > xxx V, trace to be as specified
Trr
750/4031
Capacitance
750/4001
< xx ns, If = yyA, Ir = yyA, Irec = yyyA dI/Dt=-yyA/μS
min
Forward Rrecovery
Voltage
750/4026
Forward Recovery
Time
5
6
(22/0)
Page 5
750/4026
CAP < xxpf, Vr = xxV, f=1Mhz
Vfr < xxV tr=ynS
tfr
N/A
Surge = yyA, TA = 25ºC, VR = xxxVdc,
Surge Current
750/4066
Io = yA, 10 Surges, 1 min between surges
A2 electrical other than thermal impedance
Semtech Corporation 200 Flynn Road Camarillo, CA 93012
W W W .SE MTE C H .C OM
- 16 -
HR500S (Surface Mount Package)
HR500S (Surface Mount Package)
GROUP “B” same as Mil-PRF-19500
Sub Group
1
(22/0)
2
(15/0)
Operation
Physical DIM
MIL STD
Reference
Document
750/2066
Conditions and/or Description of Operation
(TA =+ 25C Unless Otherwise Specified)
Per Device Outline
Steam Aging Required, Solder Temp = +245+ 5 C
Flux = Type ”R”, Dwell = 5 Seconds + ½ second.
Visual Magnification = 10X > 95% Coverage
Solderability
750/2026
Resistance to
Solvents
750/1022
All areas of the diode body where marking has
applied shall be brushed. Mark to remained legible
at < 3X magnification
750/1056
Test condition A, 25 cycles, dwell > 2 minutes
0 C, +2 C, -10 C / 100 C + 10 C, -2 C
Alcohol + DI Water / Boiling D.I. Water
Transfer time 10< seconds
Thermal Shock
Temp Cycling
750/1051
Condition C,
Temp. extremes : TA(low) = -55ºC+0, -10ºC
TA (high) = 175ºC
Time: Extreme = 15 minutes (min)
Number of cycles = 100
3
(22/0)
Surge Current
750/4066
ISurge = yyA, TA = 25º C, VR = xxx Vdc
Io = RATED, 10 Surges, 1 min between surges
Hermetic Seal
750/2068
Use 2068 for opaque glass body
(gross leak)
750/1071
Use 1071 for clear glass body
750/4016
IR <xμA dc, VR = xxx Vdc
750/4011
VF1, < xxx Vdc, If1 = y Adc (pulse as specified)
Electrical
VF2, < xxx Vdc, If2 = y Adc (pulse as specified)
DE-CAP
Internal Visual
(6 Devices)
Page 6
750/4021
VBR ≥xxx V dc, Ibv=yyy μA
750/2075
Design Verification
Semtech Corporation 200 Flynn Road Camarillo, CA 93012
W W W .SE MTE C H .C OM
- 17 -
HR500S
(Surface
MountMount
Package)
HR500S
(Surface
Package)
GROUP “B”, continued
Sub
Group
Operation
Pre Electrical
Intermittent Op
Life
4
(22/0)
Electrical
MIL STD
Reference
Document
750/4016
IR <xμA dc, VR = xxx Vdc
750/4011
VF1, < xxx Vdc, If1 = y Adc (pulse as specified)
750/1037
2000 cycles condition D.
750/4016
IR <xμA dc, VR = xxx Vdc
750/4011
VF1, < xxx Vdc, If1 = y Adc (pulse as specified)
VF2, < xxx Vdc, If2 = y Adc (pulse as specified)
750/4021
Deltas
Pre Electrical
Operation Life
5
(22/0)
Electrical
VBR ≥xxx V dc, Ibv=yyy μA
750/4011
Delta IR = ± yyy nAdc or 100% of pre HTRB reading,
whichever is greater.
Delta VF± xxx Vdc of pre HTRB reading
750/4016
IR <xμA dc, VR = xxx Vdc
750/4011
VF1, < xxx Vdc, If1 = y Adc (pulse as specified)
750/1027
Bias as specified. Tj = 175ºC T=1000hrs min. Post
test per A2
750/4016
IR <xμA dc, VR = xxx Vdc
750/4011
VF1, < xxx Vdc, If1 = y Adc (pulse as specified)
750/4016
750/4021
750/3101
750/4016
Deltas
Conditions and/or Description of Operation
(TA =+ 25C Unless Otherwise Specified)
750/4011
VF2, < xxx Vdc, If2 = y Adc (pulse as specified)
VBR ≥xxx V dc, Ibv=yyy μA
ZθJX
Delta IR = ± yyy nAdc or 100% of pre HTRB reading,
whichever is greater.
Delta VF± xxx Vdc of pre HTRB reading
Page 7
Semtech Corporation 200 Flynn Road Camarillo, CA 93012
Phone: 805-498-2111 Web: www.semtech.com
W W W .SE MTE C H .C OM
- 18 -
HR500S (Surface Mount Package)
HR500S (Surface Mount Package)
GROUP “B”, continued
6
(22/0)
Thermal
Resistance
Pre Electrical
High-temperature
Life
7
(32/0)
Electrical
750/4081
RθJEC < yyºC/W
750/4016
IR <xμA dc, VR = xxx Vdc
750/4011
VF1, < xxx Vdc, If1 = y Adc (pulse as specified)
750/1032
340 hours minimum TA = TSTG(max)
750/4016
IR <xμA dc, VR = xxx Vdc
750/4011
VF1, < xxx Vdc, If1 = y Adc (pulse as specified)
VF2, < xxx Vdc, If2 = y Adc (pulse as specified)
750/4021
Deltas
750/4011
Delta IR = ± yyy nAdc or 100% of pre HTRB reading,
whichever is greater.
Delta VF± xxx Vdc of pre HTRB reading
PRP
750/4065
Prsm
750/4016
IR <xμA dc, VR = xxx Vdc
750/4011
VF1, < xxx Vdc, If1 = y Adc (pulse as specified)
750/4016
8
(10/0)
Electrical
VF2, < xxx Vdc, If2 = y Adc (pulse as specified)
750/4021
Page 8
VBR ≥xxx V dc, Ibv=yyy μA
VBR ≥xxx V dc, Ibv=yyy μA
Semtech Corporation 200 Flynn Road Camarillo, CA 93012
W W W .SE MTE C H .C OM
- 19 -
Worldwide Locations
Design & Application Center and Sales Office
Sales/Support Offices
North America
Europe
Asia
Corporate Headquarters
Camarillo, California
805 498 2111
Neuchatel, Switzerland
Design Center & Applications
+ 41 32 729 4000
Seoul, Korea
+ 82 2 527 4377
San Diego, California
Design Center & Applications
858 613 3320
St. Gallen, Switzerland
+ 41 71 313 4828
San Jose, California
Design Center & Applications
408 324 3300
Redondo Beach, California
Design Center & Applications
310 698 1000
Irvine, California
Design Center & Applications
949 269 4400
Raleigh, North Carolina
Design Center & Applications
919 465 6430
Southampton, England
Design Center & Applications
+ 44 1794527 600
Courtaboeuf, France
+ 33 169 28 22 00
Hallbergmoos, Germany
+ 49 811 998 728 10
Tokyo, Japan
+ 81 3 6408 0950
Osaka, Japan
+ 81 6 6133 5608
Beijing, China
+ 86 10 6410 6855
Shanghai, China
+ 86 21 6391 0830
Shenzhen, China
Design Center & Applications
+ 86 755 8282 8515
Taipei, Taiwan
+ 886 2 2748 3380
Manila, Philippines
+ 63 2772 1834
Ipoh, Malaysia
+ 60 5312 3333
Semtech and the Semtech logo are registered marks of Semtech Corporation. Semtech reserves the right to make changes to, or discontinue any products described in this document without further notice.
©2010 Semtech Corporation. All rights reserved.
W W W .SE MTE C H .C O M