SCP-1K2 900~1200W Parallel (N+1) With PFC Function series Features : AC input 180~260VAC only PF> 0.98@ 230VAC Protections: Short circuit / Overload / Over voltage / Over temperature Built in remote sense function Built-in remote ON-OFF control Built-in power good signal output Built-in parallel operation function(N+1) Can adjust from 20~100% output voltage by external control 1-5V Forced air cooling by built-in DC fan 3 years warranty SPECIFICATION ORDER NO. OUTPUT SCP-1K2-05 SCP-1K2-09 SCP-1K2-12 SCP-1K2-15 SCP-1K2-18 SCP-1K2-24 SCP-1K2-36 SCP-1K2-48 SCP-1K2-60 SAFETY MODEL NO. 1K2S-P005 1K2S-P009 1K2S-P012 1K2S-P015 1K2S-P018 1K2S-P024 1K2S-P036 1K2S-P048 1K2S-P060 DC VOLTAGE 5V 9V 12V 15V 18V 24V 36V 48V 60V RATED CURRENT 200A 133A 100A 80A 66.6A 50A 33.3A 24A 20A CURRENT RANGE 0 ~ 200A 0 ~ 133A 0 ~ 100A 0 ~ 80A 0 ~ 66.6A 0 ~ 50A 0 ~ 33.3A 0 ~ 24A 0 ~ 20A RATED POWER 1000W 1197W 1200W 1200W 1198W 1200W 1198W 1152W 1200W 100mVp-p 120mVp-p 150mVp-p 180mVp-p 240mVp-p 360mVp-p 480mVp-p 500mVp-p RIPPLE & NOISE (max.) Note.2 100mVp-p VOLTAGE ADJ. RANGE 3.0% Typical adjustment by potentiometer 20%~100% adjustment by 1~5VDC external control VOLTAGE TOLERANCE Note.3 2.0% 1.5% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% 1.0% LINE REGULATION 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% LOAD REGULATION 1.5% 1.0% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% 0.5% SETUP, RISE, HOLD UP TIME 500ms, 200ms, 16ms at full load INPUT VOLTAGE RANGE 180 ~ 260VAC FREQUENCY RANGE 47 ~ 63Hz POWER FACTOR >0.98 / 230VAC 80% AC CURRENT INRUSH CURRENT (max.) 10A / 230VAC 60A / 230VAC LEAKAGE CURRENT (max.) 3.5mA / 240VAC OVER TEMPERATURE WORKING TEMP. WORKING HUMIDITY ENVIRONMENT STORAGE TEMP., HUMIDITY TEMP. COEFFICIENT VIBRATION SAFETY STANDARDS WITHSTAND VOLTAGE (Note. 5) SPECIAL FUNCTION NOTE COOLING 86% 89% 89% 90% 90% 110 ~ 135% Follow to output set up point Protection type : Shut down o/p voltage, re-power on to recover >100 / measure by heat sink, near transformer Protection type : Shut down o/p voltage, recovers automatically after temperature goes down -20 ~ +65 (Refer to output load derating curve) 20 ~ 90% RH non-condensing -20 ~ +85 , 10 ~ 95% RH 0.04% / (0 ~ 50 ) 10 ~ 200Hz, 2G 10min./1cycle, 60min. each along X, Y, Z axes UL60950, TUV EN60950-1 approved I/P-O/P:3KVAC I/P-FG:1.5KVAC O/P-FG:0.5KVAC ISOLATION RESISTANCE I/P-O/P, I/P-FG, OP/FG:100M Ohms / 500VDC / 25 EMI CONDUCTION & RADIATION Compliance to EN55022 (CISPR22) class A Compliance to EN61000-3-2,3 HARMONIC CURRENT EMS IMMUNITY POWER GOOD SIGNAL OTHERS 85% 84% 105 ~ 140% rated output power Note. 4 Protection type : Current limiting, delay shut down o/p voltage, re-power on to recover PROTECTION OVER VOLTAGE EMC 82% EFFICIENCY (Typ.) OVERLOAD SAFETY & 260 ~ 370VDC see the derating curve / 70% RH Compliance to EN61000-4-2,3,4,5,6,8,11, light industry level, criteria A Open collector of NPN transistor DC Voltage Adj., remote sensing, remote control, parallel operation(refer to control terminal instruction manual) MTBF By fan, >20% load or >50 fan on 37.4K hrs min. MIL-HDBK-217F(25 DIMENSION 290*120*132mm (L*W*H) PACKING 5kg; 4pcs /21kg /CARTON ) 1. All parameters NOT specially mentioned are measured at 230VAC input, rated load and 25 of ambient temperature. 2. Ripple & noise are measured at 20MHz of bandwidth by using a 12" twisted pair-wire terminated with a 0.1uf & 47uf parallel capacitor. 3. Tolerance : includes set up tolerance, line regulation and load regulation. 4. Current limiting 3 times(1.5s,3.0s,5.0s)Then intelligent auto recovery before shut down 5. The power supply is considered a component which will be installed into a final equipment. The final equipment must be re-confirmed that it still meets EMC directives. File Name: SCP-1K2-SPEC 2008-05-06 SCP-1K2 900~1200W Parallel (N+1) With PFC Function Mechanical Specification series Unit:mm 290 200 200 120 1 2 3 TB1 #6-32-4 M3(NUT) 3H-4 1 2 3 4 5 6 7 8 Vadj 103 132.5 AC INPUT LED NEG- POS+ LED 30 26.5 251 Air flow direction 89 M3(NUT) 3H-4 Terminal Pin No. Assignment Pin No. 1 2 3 Control terminal Pin No. Assignment (TB1) : Dinkle 51HDBC-O8P or equivalent Assignment AC/L AC/N FG Pin No. 1 2 3 4 Assignment VS+ VSVCI VCO Pin No. 5 6 7 8 Assignment Mating With PG PAR Dinkle 51SDB-O8P or equivalent GND INH Derating Curve Ta=25 1800 OUTPUT POWER (W) 100 LOAD (%) 80 60 40 20 -20 1600 1400 1200 1100 1000 800 600 -10 10 20 30 40 50 AMBIENT TEMPERATURE ( ) 60 70 90 110 130 150 160 180 200 220 240 260 INPUT VOLTAGE (VAC) 60Hz File Name: SCP-1K2-SPEC 2008-05-06 SCP-1K2 900~1200W Parallel (N+1) With PFC Function series Control terminal instruction manual LOAD VS+ VSVCI VCO PG PAR GND INH VS+ VSVCI VCO PG PAR GND INH USING INTERNAL VOLTAGE CONTROL LOAD LOAD LOAD VS+ VSVCI VCO PG PAR GND INH VS+ VSVCI VCO PG PAR GND INH ON/OFF SWITCH ON/OFF CONTROL BY TRANSISTOR ON/OFF CONTROL BY SWITCH REMOTE SENSING H:ON L:OFF Vout GOOD FAIL : LED OFF : LED ON O.V.P. 120% (Typ.) 120 100 VS+ VSVCI VCO PG PAR GND INH 40V / 0.5A MAX. POWER GOOD SIGNAL VS+ VSVCI VCO PG PAR GND INH OUTPUT VOLTAGE (%) LOAD LOAD DC 1-5V 80 Non-Linear 60 40 20 1 OUTPUT VOLTAGE ADJUST WITH DC 1-5V 2 3 4 5 6 EXTERNAL VOLTAGE (DC) LOAD VS+ VSVCI VCO PG PAR GND INH VS+ VSVCI VCO PG PAR GND INH VS+ VSVCI VCO PG PAR GND INH PARALLEL OPERATION WITH REMOTE SENSING V LOAD VS+ VSVCI VCO PG PAR GND INH VS+ VSVCI VCO PG PAR GND INH VS+ VSVCI VCO PG PAR GND INH PARALLEL OPERATION WITHOUT REMOTE SENSING File Name: SCP-1K2-SPEC 2008-05-06