EN

40
▪▪ High resolution: 1280x1024 pixel CMOS Sensor
▪▪ up to 1024 gray levels (10bit resolution)
▪▪ up to 500 full frames/sec
▪▪ arbitrary region of interest
▪▪ very high sensitivity
▪▪ 14 µm square pixels
▪▪ electronic “Freeze Frame” shutter
▪▪ low blooming
▪▪ programmable via CameraLink® serial interface
▪▪ asynchronous trigger
▪▪ small, compact housing
▪▪ wide power supply range
8 x 12-M4 depth 6
40
HXC13 – High speed CMOS camera for advanced industrial vision applications
Dimensions
● HXC13 (11008792)
63
Product Specification
33
63
40
Quick Start Guide
HXC13 - Digital High Speed Camera
Installation
Conformity:
Installation using
Camera Link® BASE:
Notice
See user´s Guide for the complete safety instructions!
▪▪ If required, connect a strobe
to the HIROSE connector
Safety Precautions
▪▪ Protect the sensor from dirt and
moisture.
▪▪ Never open the camera housing.
▪▪ Avoid camera contamination by
foreign objects.
Environmental requirements:
Storage temp.
Operating temp.
Housing temp.
Humidity
-10°C ... +70°C
+5°C ... +50°C
max. +50°C
10 % ... 90 %
Non-condensing
Further Information
For further information on our products visit www.baumer.com
For technical issues, please contact our technical support:
[email protected] · Phone +49 (0)3528 4386-0 · Fax +49 (0)3528 4386-86
© Baumer Optronic GmbH · Badstrasse 30 · DE-01454 Radeberg, Germany
Technical data has been fully checked, but accuracy of printed matter not guaranteed.
Subject to change without notice. Printed in Germany 04/12. V1.1
11037740
8 x 12-M4 depth 6
▪▪ Connect the camera to
power supply
Installation sample
1 - Framegrabber board; 2 - Camera Link®
cable; 3 - Cable for strobe; 4 - Power cable
Installation using
Camera Link® MEDIUM /
FULL:
33
63
▪▪ Connect the camera using
two appropriate cables to
the framegrabber board on
your PC (this configuration
requires the BASE and the
FULL Camera Link® line)
▪▪ If required, connect a strobe
to the HIROSE connector
▪▪ Connect the camera to
power supply
40
Note: This equipment has been tested and found to
comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed
to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy and, if
not installed and used in accordance with the instructios,
may cause harmful interference to radio communications.
However, there is no guarantee that interference will not
occure in a particular installation. If this equipment does
cause harmful interference to radio or television reception,
which can be determined by turning the equipment off an
on, the user is encouraged to try to correct the interference
by one or more of the following measures:
▪▪ Reorient or relocate the receiving antenna.
▪▪ Increase the separation between the equipment and the
receiver.
▪▪ Connect the equipment into an outlet on a circuit different
from that to which the receiver is connected.
▪▪ Consult the dealer or an experienced radio/TV technician
for help.
40
FCC – Class B device
▪▪ Connect the camera using
an appropriate cable to the
framegrabber board on your
PC using the lower mdr-26
jack on the camera side
63
CE, FCC Part 15 Class B, RoHS
Dimensions
● HXC13-F (11008791)
40
Safety
Installation sample
1 - Framegrabber board; 2 - Camera Link®
cable; 3 - Cable for strobe; 4 - Power cable
General Description
LED Signaling
1
Dimensions
● HXC13 M42-Mount (11053411)
3
40
2
LED
Nr.
Description
▪▪ Camera is de-energized.
▪▪ If LED is off, despite the camera is powered, data is stored to the
internal EEPROM.
No (other) activity is possible.
yellow
The camera is configuring the internal FPGA.
No other activity is possible.
green
The camera is fully operational.
red
▪▪ The camera's microcontroller detected a configuration error.
▪▪ The camera's FPGA could not be loaded.
The camera is not functional. Try reload configuration data.
4
Nr.
Description
1
(respective) lens mount
4
Camera Link® Base socket
2
Power supply
5
Signaling-LED
3
Camera Link® Full socket
40
off
63
33
red flash ▪▪ The camera's microcontroller or FPGA is loading data.
▪▪ Camera verifies checksum.
No other activity is possible.
40
5
8 x 12-M4 depth 6
Meaning
63
Signal
Documentation and Software
Power Supply Interface
Camera Link® Interfaces
Notice
CL BASE
The camera has two CameraLink sockets. To differentiate between CameraLink Base and CamerLink Full socket, please look
at the label. You can not use the CL Full socket alone!
Base CameraLink®
Full CameraLink®
1
6
Signal
GND
X0X1X2XCLKX3SERTC+
SERTFGCC1CC2+
CC3CC4+
GND
Pin
14
15
16
17
18
19
20
21
22
23
24
25
26
Signal
GND
X0+
X1+
X2+
XCLK+
X3+
SERTCSERTFG+
CC1+
CC2CC3+
CC4GND
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
Signal
GND
Y0Y1Y2YCLKY3100 Ω term.
Z0Z1Z2ZCLKZ3GND
Pin
14
15
16
17
18
19
20
21
22
23
24
25
26
Signal
GND
Y0+
Y1+
Y2+
YCLK+
Y3+
100 Ω term.
Z0+
Z1+
Z2+
ZCLK+
Z3+
GND
5
3
Pin
1 (white)
2 (brown)
Signal
VCC
VCC
Pin
3 (green)
4 (yellow)
4
Signal
STRB
DGND
Pin
5 (grey)
6 (pink)
Power Supply
Power VCC
8 VDC ... 24 VDC
W
5W
Signal
GND
GND
.baumer.co
ww
m
2
Pin
1
2
3
4
5
6
7
8
9
10
11
12
13
Notice
Power Socket
w
CL FULL
Baumer
Type: HXCXXx (xxxxxxx)
R1.0
S/N: 000XXXXX
The product documentation and software as well as accompanying tools and applications notes can be obtained in the
download area:
http://www.baumer.com/de-en/services/member-area
A registration is required.