40 ▪▪ High resolution: 1280x1024 pixel CMOS Sensor ▪▪ up to 1024 gray levels (10bit resolution) ▪▪ up to 500 full frames/sec ▪▪ arbitrary region of interest ▪▪ very high sensitivity ▪▪ 14 µm square pixels ▪▪ electronic “Freeze Frame” shutter ▪▪ low blooming ▪▪ programmable via CameraLink® serial interface ▪▪ asynchronous trigger ▪▪ small, compact housing ▪▪ wide power supply range 8 x 12-M4 depth 6 40 HXC13 – High speed CMOS camera for advanced industrial vision applications Dimensions ● HXC13 (11008792) 63 Product Specification 33 63 40 Quick Start Guide HXC13 - Digital High Speed Camera Installation Conformity: Installation using Camera Link® BASE: Notice See user´s Guide for the complete safety instructions! ▪▪ If required, connect a strobe to the HIROSE connector Safety Precautions ▪▪ Protect the sensor from dirt and moisture. ▪▪ Never open the camera housing. ▪▪ Avoid camera contamination by foreign objects. Environmental requirements: Storage temp. Operating temp. Housing temp. Humidity -10°C ... +70°C +5°C ... +50°C max. +50°C 10 % ... 90 % Non-condensing Further Information For further information on our products visit www.baumer.com For technical issues, please contact our technical support: [email protected] · Phone +49 (0)3528 4386-0 · Fax +49 (0)3528 4386-86 © Baumer Optronic GmbH · Badstrasse 30 · DE-01454 Radeberg, Germany Technical data has been fully checked, but accuracy of printed matter not guaranteed. Subject to change without notice. Printed in Germany 04/12. V1.1 11037740 8 x 12-M4 depth 6 ▪▪ Connect the camera to power supply Installation sample 1 - Framegrabber board; 2 - Camera Link® cable; 3 - Cable for strobe; 4 - Power cable Installation using Camera Link® MEDIUM / FULL: 33 63 ▪▪ Connect the camera using two appropriate cables to the framegrabber board on your PC (this configuration requires the BASE and the FULL Camera Link® line) ▪▪ If required, connect a strobe to the HIROSE connector ▪▪ Connect the camera to power supply 40 Note: This equipment has been tested and found to comply with the limits for a Class B digital device, pursuant to part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference in a residential environment. This equipment generates, uses, and can radiate radio frequency energy and, if not installed and used in accordance with the instructios, may cause harmful interference to radio communications. However, there is no guarantee that interference will not occure in a particular installation. If this equipment does cause harmful interference to radio or television reception, which can be determined by turning the equipment off an on, the user is encouraged to try to correct the interference by one or more of the following measures: ▪▪ Reorient or relocate the receiving antenna. ▪▪ Increase the separation between the equipment and the receiver. ▪▪ Connect the equipment into an outlet on a circuit different from that to which the receiver is connected. ▪▪ Consult the dealer or an experienced radio/TV technician for help. 40 FCC – Class B device ▪▪ Connect the camera using an appropriate cable to the framegrabber board on your PC using the lower mdr-26 jack on the camera side 63 CE, FCC Part 15 Class B, RoHS Dimensions ● HXC13-F (11008791) 40 Safety Installation sample 1 - Framegrabber board; 2 - Camera Link® cable; 3 - Cable for strobe; 4 - Power cable General Description LED Signaling 1 Dimensions ● HXC13 M42-Mount (11053411) 3 40 2 LED Nr. Description ▪▪ Camera is de-energized. ▪▪ If LED is off, despite the camera is powered, data is stored to the internal EEPROM. No (other) activity is possible. yellow The camera is configuring the internal FPGA. No other activity is possible. green The camera is fully operational. red ▪▪ The camera's microcontroller detected a configuration error. ▪▪ The camera's FPGA could not be loaded. The camera is not functional. Try reload configuration data. 4 Nr. Description 1 (respective) lens mount 4 Camera Link® Base socket 2 Power supply 5 Signaling-LED 3 Camera Link® Full socket 40 off 63 33 red flash ▪▪ The camera's microcontroller or FPGA is loading data. ▪▪ Camera verifies checksum. No other activity is possible. 40 5 8 x 12-M4 depth 6 Meaning 63 Signal Documentation and Software Power Supply Interface Camera Link® Interfaces Notice CL BASE The camera has two CameraLink sockets. To differentiate between CameraLink Base and CamerLink Full socket, please look at the label. You can not use the CL Full socket alone! Base CameraLink® Full CameraLink® 1 6 Signal GND X0X1X2XCLKX3SERTC+ SERTFGCC1CC2+ CC3CC4+ GND Pin 14 15 16 17 18 19 20 21 22 23 24 25 26 Signal GND X0+ X1+ X2+ XCLK+ X3+ SERTCSERTFG+ CC1+ CC2CC3+ CC4GND Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 Signal GND Y0Y1Y2YCLKY3100 Ω term. Z0Z1Z2ZCLKZ3GND Pin 14 15 16 17 18 19 20 21 22 23 24 25 26 Signal GND Y0+ Y1+ Y2+ YCLK+ Y3+ 100 Ω term. Z0+ Z1+ Z2+ ZCLK+ Z3+ GND 5 3 Pin 1 (white) 2 (brown) Signal VCC VCC Pin 3 (green) 4 (yellow) 4 Signal STRB DGND Pin 5 (grey) 6 (pink) Power Supply Power VCC 8 VDC ... 24 VDC W 5W Signal GND GND .baumer.co ww m 2 Pin 1 2 3 4 5 6 7 8 9 10 11 12 13 Notice Power Socket w CL FULL Baumer Type: HXCXXx (xxxxxxx) R1.0 S/N: 000XXXXX The product documentation and software as well as accompanying tools and applications notes can be obtained in the download area: http://www.baumer.com/de-en/services/member-area A registration is required.