Datasheet

XFPM Data sheet
Pre-amplified/5V Excitation/Gauge
■Features
On-chip amplification and temperature compensations
Pre-calibration of offset voltage and span
Dual-in-line package (DIP)
■Ordering Information
XFPM-025KP G R
Terminal leadsdirection
Model
No Mark:
Rated Pressure
KP:kPa
MP:MPa
Pressure type
R :
G:Gauge(Positive pressure)
GV:Gauge Pressure(Negative pressure)
GW:Gauge Pressure(Positive/Negative pressure)
Weight
(grams)
RoHS compliance
1.2
Measurable pressure
range(kPa)
-100 to 100
0 to -100
0 to 25
0 to 50
0 to 100
0 to 200
0 to 1000
Part number
XFPM-100KPGW
XFPM-100KPGV
XFPM-025KPG
XFPM-050KPG
XFPM-100KPG
XFPM-200KPG
XFPM-001MPG
XFPM-100KPGWR
XFPM-100KPGVR
XFPM-025KPGR
XFPM-050KPGR
XFPM-100KPGR
XFPM-200KPGR
XFPM-001MPGR
■Specifications
100KPGW
Model
Recommended operating conditions
Pressure type
Rated pressure
Measurable pressure range
Temperature range
Pressure media
Supply voltage(constant)
+/-100
-100 to100
100KPGV
-100
0 to -100
025KPG
050KPG
100KPG
200KPG
Gauge pressure
50
100
200
0 to 50
0 to 100
0 to 200
0 to 85
Non-corrosive gases only (No liquid)
5+/-0.25
25
0 to 25
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
8
-40 to 125
-40 to 125
30 to 80 (Non dew condition)
Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25deg.C)
Power consumption
10mA max.
Output impedance
10Ω max.
Source current
0.2mA max.
Sink current
2mA max.
Response time
2 (for the reference)
Output span voltage
4.5
Offset voltage *1
*2
*3
0.2+/-0.1125 (at 0 kPa )
Output voltage at full scale *1
*4
*5
4.7+/-0.1125 (at rated pressure)
Accuracy *1
+/-2.5
Maximum excitation voltage
Operating temperature
Storage temperature
Operating humidity
*1 Excluding input voltage error.
*2 0.2+/-0.1125V(at -100kPa )
*4 4.7+/-0.1125V(at +100kPa)
0-85deg.C
*3 0.2+/-0.1125V(at 0kPa)
*5 4.7+/-0.1125V(at -100kPa)
1
001MPG
1000
0 to 1000
1.5 times
of rating
pressure
Unit
kPa
kPa
deg.C
VDC
VDC
deg.C
deg.C
%RH
mA
Ω
mA
mA
msec.
V
V
V
%FS/0-85deg.C
XFPM Data sheet
Pre-amplified/5V Excitation/Gauge
■Outline dimensions■
2
XFPM Data sheet
Pre-amplified/5V Excitation/Gauge
■Connection diagram■
View from Lavel
Marking
■Transfer Function■
Vout = Vs×( P×α+β) ± (Pressure Error×Temperature Error Multiplier×α×Vs)
Vs=Vcc=5.0V
P=Input pressure(kPa)
Model
XFPM-100KPGW
XFPM-100KPGV
XFPM-025KPG
XFPM-050KPG
XFPM-100KPG
XFPM-200KPG
XFPM-001MPG
XFPM-100KPGWR
XFPM-100KPGVR
XFPM-025KPGR
XFPM-050KPGR
XFPM-100KPGR
XFPM-200KPGR
XFPM-001MPGR
Measurable
pressure
range(kPa)
-100 to 100
0 to -100
0 to 25
0 to 50
0 to 100
0 to 200
0 to 1000
Temperature Error Multiplier
3
α
β
Pressure Error
(kPa)
0.0045
-0.009
0.036
0.018
0.009
0.0045
0.0009
0.49
0.04
0.04
0.04
0.04
0.04
0.04
5
2.5
0.625
1.25
2.5
5
25
XFPM Data sheet
Pre-amplified/5V Excitation/Gauge
■Output characteristics■
↑Output voltage(mV)
XFPM-100KPGV
XFPM-025KPG
XFPM-050KPG
XFPM-100KPG
XFPM-200KPG
XFPM-001MPG
XFPM-100KPGVR
XFPM-025KPGR
XFPM-050KPGR
XFPM-100KPGR
XFPM-200KPGR
XFPM-001MPGR
Output voltage
at full scale
4.7V
Output span
voltage
Offset voltage
0.2V
Rated pressure
0kPa
→Pressure(kPa)
Atomospheric
pressure
XFPM-100KPGW
↑Output voltage(mV)
XFPM-100KPGWR
Output voltage
at full scale
4.7V
Output span
voltage
Offset voltage
0.2V
-100kPa
0kPa
Atomospheric
pressure
Note ;
+100kPa
→Pressure(kPa)
Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
Please keep the sensors sealed using static shielding bags on storage.The pins of the sensor are plated by Ag.
If the sensors expose to an atmosphere, the pins will be black by sulfuration.
Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress
such as mounting, installation and etc. over longtime using.
If you have any questions regarding technical issues or specifications, please contact us.
Fujikura Ltd. Sensor Department
5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072
E-mail : [email protected]
4