Data sheet[PDF336KB]

XFHM Data sheet
Pre-amplified/5V Excitation/Gauge
■Features
On-chip amplification and temperature compensations
Pre-calibration of offset voltage and span
Horizonral pressure port
■Ordering Information
XFHM-025KP G R
Terminal leadsdirection
Model
R
Rated Pressure
KP:kPa
MP:MPa
:
Pressure type
G:Gauge(Positive pressure)
GV:Gauge Pressure(Negative pressure)
GW:Gauge Pressure(Positive/Negative pressure)
Weight
(grams)
RoHS compliance
0.6
Measurable pressure
range(kPa)
-100 to 100
0 to -100
0 to 25
0 to 50
0 to 100
0 to 200
0 to 1000
Part number
XFHM-100KPGWR
XFHM-100KPGVR
XFHM-025KPGR
XFHM-050KPGR
XFHM-100KPGR
XFHM-200KPGR
XFHM-001MPGR
■Specifications
100KPGW
Model
Recommended operating conditions
Pressure type
Rated pressure
Measurable pressure range
Temperature range
Pressure media
Supply voltage(constant)
+/-100
-100 to100
100KPGV
-100
0 to -100
025KPG
050KPG
100KPG
200KPG
Gauge pressure
50
100
200
0 to 50
0 to 100
0 to 200
0 to 85
Non-corrosive gases only (No liquid)
5+/-0.25
25
0 to 25
Absolute maximum rating
Maximum load pressure
Twice of rated pressure
8
-40 to 125
-40 to 125
30 to 80 (Non dew condition)
Electrical characteristics (Excitation voltage Vcc=5.0V constant ,ambient temperature Ta=25deg.C)
Power consumption
10mA max.
Output impedance
10Ω max.
Source current
0.2mA max.
Sink current
2mA max.
Response time
2 (for the reference)
Output span voltage
4.5
Offset voltage *1
*2
*3
0.2+/-0.1125 (at 0 kPa )
Output voltage at full scale *1
*4
*5
4.7+/-0.1125 (at rated pressure)
Accuracy *1
+/-2.5
Maximum excitation voltage
Operating temperature
Storage temperature
Operating humidity
*1 Excluding input voltage error.
*2 0.2+/-0.1125V(at -100kPa )
*4 4.7+/-0.1125V(at +100kPa)
0-85deg.C
*3 0.2+/-0.1125V(at 0kPa)
*5 4.7+/-0.1125V(at -100kPa)
1
001MPG
1000
0 to 1000
1.5 times
of rating
pressure
Unit
kPa
kPa
deg.C
VDC
VDC
deg.C
deg.C
%RH
mA
Ω
mA
mA
msec.
V
V
V
%FS/0-85deg.C
XFHM Data sheet
Pre-amplified/5V Excitation/Gauge
■Outline dimensions■
■Connection diagram■
View from Lavel
Marking
2
XFHM Data sheet
Pre-amplified/5V Excitation/Gauge
■Transfer Function■
Vout = Vs×( P×α+β) ± (Pressure Error×Temperature Error Multiplier×α×Vs)
Vs=Vcc=5.0V
P=Input pressure(kPa)
Model
XFHM-100KPGWR
XFHM-100KPGVR
XFHM-025KPGR
XFHM-050KPGR
XFHM-100KPGR
XFHM-200KPGR
XFHM-001MPGR
Measurable
pressure
range(kPa)
-100 to 100
0 to -100
0 to 25
0 to 50
0 to 100
0 to 200
0 to 1000
Temperature Error Multiplier
3
α
β
Pressure Error
(kPa)
0.0045
-0.009
0.036
0.018
0.009
0.0045
0.0009
0.49
0.04
0.04
0.04
0.04
0.04
0.04
5
2.5
0.625
1.25
2.5
5
25
XFHM Data sheet
Pre-amplified/5V Excitation/Gauge
■Output characteristics■
XFHM-100KPGWR
XFHM-100KPGVR
XFHM-025KPGR
XFHM-050KPGR
XFHM-100KPGR
XFHM-200KPGR
↑Output voltage(mV)
Output voltage
at full scale
4.7V
Output span
voltage
Offset voltage
0.2V
Rated pressure
0kPa
Atomospheric
pressure
XFHM-100KPGWR
→Pressure(kPa)
↑Output voltage(mV)
Output voltage
at full scale
4.7V
Output span
voltage
Offset voltage
0.2V
-100kPa
0kPa
Atomospheric
pressure
Note ;
+100kPa
→Pressure(kPa)
Please read instruction “Notes” before using the sensor.
Fujikura reserves the right to change specifications without notice.
Please keep the sensors sealed using static shielding bags on storage.The pins of the sensor are plated by Ag.
If the sensors expose to an atmosphere, the pins will be black by sulfuration.
Please set Zero-calibration function up your products. The offset voltage may be shifted some mechanical stress
such as mounting, installation and etc. over longtime using.
If you have any questions regarding technical issues or specifications, please contact us.
Fujikura Ltd. Sensor Department
5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan
Phone +81-(0)3-5606-1072
E-mail : [email protected]
4