XFPM,XFHM Data sheet Pre-amplified/5V Excitation/Gauge Features . . . . . Applications . Industrial instrumentation . Pressure switch, Pneumatic device Two accuracy ranks, 1.5 FS and 2.5 FS available Volt level output On-chip amplification and temperature compensations Pre-calibration of offset voltage and span Non-corrosive liquid measurable (XFPMC, XFHMC only) . Medical device Part number for ordering XFPM C - 025KP G R H Accuracy No mark : H : Model XFPM XFHM Rated pressure (Pa) Available pressure media No mark : Non-corrosive gas only Pressure type C : Non-corrosive gas and liquid G : Gauge (Positive pressure) Terminal leads direction (See Outline Diagram) No mark : GV : Gauge (Negative pressure) GW : Gauge (Bipolar pressure) Pressure type 2.5 FS 1.5 FS R : Gauge pressure XFPM XFHM Dual-In-line-Package (DIP) Horizontal pressure port DIP Model Package configuration Measurable pressure range (kPa) 100 100 0 100 0 25 0 50 0 100 0 200 0 1000 XFPM-100KPGW(H) XFPM-100KPGV(H) XFPM-025KPG(H) XFPM-050KPG(H) XFPM-100KPG(H) XFPM-200KPG(H) XFPM-001MPG(H) XFPM-100KPGWR(H) XFPM-100KPGVR(H) XFPM-025KPGR(H) XFPM-050KPGR(H) XFPM-100KPGR(H) XFPM-200KPGR(H) XFPM-001MPGR(H) XFPMC-100KPGW(H) XFPMC-100KPGV(H) XFPMC-025KPG(H) XFPMC-050KPG(H) XFPMC-100KPG(H) XFPMC-200KPG(H) XFPMC-001MPG(H) 100KPGW(H) 100KPGV(H) 025KPG(H) Part number for ordering XFPMC-100KPGWR(H) XFHM-100KPGW(H) XFPMC-100KPGVR(H) XFHM-100KPGV(H) XFPMC-025KPGR(H) XFHM-025KPG(H) XFPMC-050KPGR(H) XFHM-050KPG(H) XFPMC-100KPGR(H) XFHM-100KPG(H) XFPMC-200KPGR(H) XFHM-200KPG(H) XFPMC-001MPGR(H) XFHM-001MPG(H) XFHM-100KPGWR(H) XFHM-100KPGVR(H) XFHM-025KPGR(H) XFHM-050KPGR(H) XFHM-100KPGR(H) XFHM-200KPGR(H) XFHM-001MPGR(H) XFHMC-100KPGW(H) XFHMC-100KPGV(H) XFHMC-025KPG(H) XFHMC-050KPG(H) XFHMC-100KPG(H) XFHMC-200KPG(H) XFHMC-001MPG(H) XFHMC-100KPGWR(H) XFHMC-100KPGVR(H) XFHMC-025KPGR(H) XFHMC-050KPGR(H) XFHMC-100KPGR(H) XFHMC-200KPGR(H) XFHMC-001MPGR(H) 200KPG(H) 001MPG(H) Unit Specifications Model/Rated pressure 050KPG(H) 100KPG(H) Recommended operating conditions Pressure type Gauge pressure 100 100 25 50 100 200 1000 Rated pressure 1.020 1.020 0.255 0.510 1.020 2.040 10.20 Measurable pressure range 100 100 0 100 0 25 0 50 0 100 0 200 0 1000 Pressure media 1 XFPM, XFHM : Non-corrosive gas only, XFPMC, XFHMC : Non-corrosive gas and liquid Excitation voltage 5.0 0.25 Absolute maximum rating 1.5times of rated pressure Maximum load pressure Twice of rated pressure Maximum excitation voltage 8 Operating temperature 40 125 Storage temperature 40 125 Operating humidity 30 80 (No dew condensation) Electric performances/characteristics(Excitation voltage Vcc=5.0V constant, Ambient temperature Ta=25 ) Current consumption less than 10 Output impedance less than 10 Source current less than 0.2 Sink current less than 2 Mechanical response time 2 (For the reference) Full scale span voltage 4.5 Offset voltage 2 0.2 0.1125, 0.2 0.0675(H) Full scale span voltage 2 4.7 0.1125, 4.7 0.0675(H) Accuracy 2 2.5, 1.5(H) Note ; 1) Please consult us available liquid pressure media when you choose the C models. 2) Excluding input voltage error. 1 kPa kg/cm2 kPa VDC VDC RH mA mA mA msec V V V FS/0 85 XFPM,XFHM Data sheet Pre-amplified/5V Excitation/Gauge Outline dimensions unit : mm XFPM 4 5 6 3 2 1 C0.5 3 2 4 3 14 1 4.5 0.6 Vent hole R1.5 15.24(600mil) 5 Pressure port 0.8 max 15 2.2 0.5 6 8 5 0.2 4 12 Terminal leads Labelled faceplate 6.8 2.8 Recommended footprint for PCB 6- 1.8(Diameter of lands) 2.54 2.54 0.5 60 1.2 2.54 2.54 6- 0.9(Diameter of through holes) 15.2 (unit : mm) unit : mm XFPM-R 4 0.2 8 0.8 Pressure port 2.2 0.5 3 14 R1.5 4 5 6 3 2 4.5 1 15.24(600mil) 5 max 15 6 4 5 12 C0.5 1 2 0.6 Vent hole 3 Terminal leads Recommended footprint for PCB 2.54 2.54 6- 0.9(Diameter of through holes) 6- 1.8(Diameter of lands) 2.54 2.54 60 1.2 0.5 Labelled faceplate 2.8 6.8 15.2 2 (unit : mm) XFPM,XFHM Data sheet Pre-amplified/5V Excitation/Gauge Outline dimensions unit : mm 2.54 2.54 1 2 3 6 5 4 5.5 XFHM Pressure port (14) 0.25 1 0.6 3.4 2.6 7.6 3.2 15 6 10.15 1.2 Vent hole 8 Labelled faceplate 6 5 Recommended footprint for PCB 4 6- 1(Diameter of through holes) 2.54 2.54 8 6- 1.8(Diameter of lands) 1 2 3 10 unit : mm 2.54 2.54 XFHM-R 2 3 6 5 4 5.5 1 (unit : mm) Pressure port (14) 1.2 4.7 2.6 3.4 (7.6) 1.55 3.2 1 6 0.6 0.25 Recommended footprint for PCB 8 Labelled faceplate 6 5 4 6- 1(Diameter of through holes) 2.54 2.54 8 6- 1.8(Diameter of lands) 1 15 Vent hole 10.16 1 2 3 10 3 (unit : mm) Pre-amplified/5V Excitation/Gauge XFPM,XFHM Data sheet Connection diagram XFPM, XFHM Vcc(DC5V) Vcc Vout Vout GND C2 C1 GND Remarks : 1) C1 : Connect 680pF capacitor within 2cm distance from leads. 2) C2 : Connect 0.01 F or more capacitor within 2cm distance from leads. 3) 4 and 5 pins must be No Connection. Open them as floating ones completely, and do NOT connect to other line or each other. Note ; Please read instruction “Notes” before using the sensor. Fujikura reserves the right to change specifications without notice. If you have any questions regarding technical issues or specifications, please contact us. Sensor Engineering Department 5-1 Kiba 1-chome, Koto-ku, Tokyo 135-8512, Japan Phone +81-(0)3-5606-1072 Fax. +81-(0)3-5606-1538 4 E-mail : [email protected]