RF100 RF103

HIGH REPEATABILITY
BROADBAND
CENTIGRID® RELAYS
DPDT
SERIES
DESIGNATION
RF100
RF103
RELAY TYPE
RF100
Repeatable, RF, Centigrid® relay
RF103
Sensitive, repeatable, RF, Centigrid® relay
INTERNAL CONSTRUCTION
PERFORMANCE FEATURES
The ultraminiature RF100 and RF103 relays are designed to provide improved
RF signal repeatability over the frequency range. These relays are highly
UNI-FRAME
UPPER
STATIONARY
CONTACT
ARMATURE
suitable for use in attenuator and other RF circuits, the RF100 and RF103
feature:
MOVING CONTACT
LOWER
STATIONARY
CONTACT
• High repeatability.
• Broader bandwidth.
• Metal enclosure for EMI shielding.
• Ground pin option to improve case grounding.
• High isolation between control and signal paths.
• Highly resistant to ESD.
CONSTRUCTION FEATURES
The following unique construction features and manufacturing techniques
provide excellent resistance to environmental extremes and overall high
reliability.
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
–65°C to +125°C
Temperature Storage
(Ambient)
Operating –55°C to +85°C
Vibration
(General Note 1)
10 g’s to 500 Hz
Shock
(General Note 1)
30 g’s,
6 msec, half-sine
Enclosure
rigidity.
• Minimum mass components and welded construction provide maximum
resistance to shock and vibration.
• Advanced cleaning techniques provide maximum assurance of internal
Hermetically sealed
RF100
0.09 oz. (2.55g) max.
RF103
0.16 oz. (4.5g) max.
Weight
RF100 RF103 Page 19
• Uni-frame motor design provides high magnetic efficiency and mechanical
cleanliness.
• Gold-plated precious metal alloy contacts ensure reliable switching.
• Hermetically sealed.
• Solderable leads.
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
©2003 TELEDYNE RELAYS
RF100 RF103/1203/Q1
RF & MICROWAVE
SERIES
Isolation Pole to Pole (RF Note 5)
-20
-20
-30
-30
Isolation (dB)
Isolation (dB)
Isolation Across Contacts (RF Note 4)
-40
-40
-50
-50
-60
-60
0
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
0
6000
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
6000
Frequency (MHz)
Frequency (MHz)
VSWR (RF Note 6)
Insertion Loss (RF Note 6)
0
3.00
-0.2
2.60
-0.4
-0.6
2.20
-0.8
VSWR
Insertion Loss (dB)
-1
1.80
-1.2
-1.4
1.40
-1.6
-1.8
0
1.00
500
1000
1500
2000
2500
3000
3500
4000
4500
5000
5500
0
6000
500
1000
1500
2000
Frequency (MHz)
2500
3000
3500
4000
4500
5000
5500
6000
Frequency (MHz)
RF100 Time Response (RF Note 6)
1.1
0.9
90%
0.7
Volt
RF & MICROWAVE
SERIES RF100 AND RF103
TYPICAL RF CHARACTERISTICS (See RF Notes)
37ps reference
0.5
81.1ps propagation delay time
0.3
58.1ps pulse rise time
10%
0.1
-0.1
-100
0
100
200
300
400
500
600
700
800
900
Time (ps)
RF NOTES
1. Test conditions:
2.
3.
4.
5.
6.
7.
a. Fixture: .031" copper clad, reinforced PTFE, RT/duroid® 6002 with SMA connectors. (RT/duroid® is a
registered trademark of Rogers Corporation.)
b. Room ambient temperature.
c. Terminals not tested were terminated with 50-ohm load.
d. Contact signal level: –10 dBm.
e. No. of test samples: 2.
Data presented herein represents typical characteristics and is not intended for use as specification limits.
Data is per pole, except for pole-to-pole data.
Data is the average from readings taken on all open contacts.
Data is the average from readings taken on poles with coil energized and de-energized.
Data is the average from readings taken on all closed contacts.
Test fixture effect de-embedded from frequency and time response data.
©2003 TELEDYNE RELAYS
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
RF100 RF103 Page 20
RF100 RF103/1203/Q1
RF & MICROWAVE
TYPICAL RF INSERTION LOSS REPEATABILITY CHARACTERISTICS (NOTES 1 AND 2)
SERIES RF100 AND RF103
REPEATABILITY CHARACTERISTICS RF100 RELAYS
90
80
70
60
50
40
30
20
10
0
0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 0.18 0.20
Normally Open
% Total Number Recorded Test Cycles
% Total Number Recorded Test Cycles
Normally Closed
100
100
90
80
70
60
50
40
30
20
10
0
0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 0.18 0.20
Repeatability (dB)
Repeatability (dB)
REPEATABILITY CHARACTERISTICS RF103 RELAYS
100
90
80
70
60
50
40
30
20
10
0
0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 0.18 0.20
Repeatability (dB)
Normally Open
% Total Number Recorded Test Cycles
% Total Number Recorded Test Cycles
Normally Closed
100
90
80
70
60
50
40
30
20
10
0
0.02 0.04 0.06 0.08 0.10 0.12 0.14 0.16 0.18 0.20
Repeatability (dB)
RF INSERTION LOSS REPEATABILITY NOTES
1. Test conditions:
a. Fixture: .031" copper clad, reinforced PTFE, RT/duroid® 6002 with SMA connectors. (RT/duroid® is a
registered trademark of Rogers Corporation.)
b. Relay header is in contact with, but not soldered to, ground plane or connected to ground via ground pin.
c. Test performed at room ambient temperature.
d. Contact signal level: 20 dBm.
2. Data presented herein represents typical characteristics and is not intended for use as specification limits.
3. Insertion loss repeatability measured over frequency range from .3 MHz to 4 GHz.
RF100 RF103 Page 21
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
©2003 TELEDYNE RELAYS
RF100 RF103/1203/Q1
RF & MICROWAVE
SERIES RF100 AND RF103
GENERAL ELECTRICAL SPECIFICATIONS (@25°C)
Contact arrangement
DPDT
Rated duty
Continuous
Contact resistance
.100 ohm max. initial (measured 1/8" from the header)
Contact load rating
Low level: 10 to 50 µA, 10 to 50 mV
Contact life rating
10,000,000 cycles typical at low level
RF100: 369–500 mW typical @ nominal rated voltage
RF103: 180–250 mW typical @ nominal rated voltage
Coil operating power
Operate time
Release time
RF100
4.0 ms. max.
RF103
6.0 ms. max.
RF100
3.0 ms. max.
RF103
3.0 ms. max.
Intercontact capacitance
0.4 pF typical
Insulation resistance
1,000 MΩ min. (between mutually isolated terminals)
Dielectric strength
350 VRMS / 60 Hz @ atmospheric pressure
DETAILED ELECTRICAL SPECIFICATIONS (@25°C)
RF100-5
RF103-5
RF100-12
RF103-12
5.0
12.0
RF100
50
390
RF103
100
800
3.6
9.0
BASE PART NUMBERS
Coil voltage, nominal, VDC
Coil resistance, ohms ± 20%
Pick-up voltage max, VDC
OUTLINE DIMENSIONS
.031 (.79)
REF.
.375
(9.53)
SQ. MAX.
.335
(8.51)
SQ. MAX.
7
8
.035 (.89)
REF.
2
6
5
1
4
H DIMENSION
MAX.
0.100 0.010
(2.54 0.25)
H
3
TERMINAL NUMBERING
SCHEMATIC
• TERMINAL NUMBERING AND SCHEMATIC ARE AS VIEWED FROM THE TERMINALS.
• DIMENSIONS ARE IN INCHES (MILLIMETERS).
• SCHEMATIC AND EXTERNAL DIMENSIONS SHOWN WITHOUT GROUND PINS.
• TO ORDER THE CASE GROUND OPTION, AFTER THE SERIES DESIGNATOR, ADD “Y” TO
THE PART NUMBER FOR TAB POSITION OR “Z” TO THE PART NUMBER FOR CENTER
POSITION.
EXAMPLE: RF103Y-COIL VOLTAGE
RF100
.290
(7.37)
RF103
.395
(10.03)
.75 (19.05) MIN.
+.002
.017 -.001
+.05
(.43 -.03 )
EXTERNAL DIMENSIONS
GENERAL NOTES
1. Relays will exhibit no contact chatter in excess of 10 µsec or transfer in excess of 1 µsec.
©2003 TELEDYNE RELAYS
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
www.teledynerelays.com
RF100 RF103 Page 22
RF100 RF103/1203/Q1