Datasheet

Series RF312/RF332
DPDT Non-Latching Electromechanical Relay
Signal Integrity up to 12Gbps
HIGH REPEATABILITY,
DC-8 GHz TO-5 RELAYS
DPDT
SERIES
RELAY TYPE
RF312
Repeatable, RF relay
RF332
Sensitive Repeatable, RF relay
DESCRIPTION
CONSTRUCTION FEATURES
The ultra miniature RF312 is designed to improve upon
the RF300/RF303 relay’s high frequency performance. The
RF312/RF332 offers monotonic insertion loss to 8 GHz.
This improvement in RF insertion loss over the frequency
range, makes these relays highly suitable for use in
attenuator and other RF circuits. The sensitive RF332 relay
has a high resistance coil, thus requiring extremely low
operating power (200 mW typical). The advantages of
reduced heat dissipation and power supply demands are a
plus. The RF312/RF332 features:
The following unique construction features and
manufacturing techniques provide excellent resistance to
environmental extremes and overall high reliability.
• Uni-frame motor design provides high magnetic
efficiency and mechanical rigidity.
• Minimum mass components and welded construction
provide maximum resistance to shock and vibration.
• Advanced cleaning techniques provide maximum
assurance of internal cleanliness.
• Gold-plated precious metal alloy contacts ensure
reliable switching.
• Hermetically sealed.
• Solder-Dipped Leads, (RoHS compliant solder option
available)
• High repeatability.
• Broader bandwidth.
• Metal enclosure for EMI shielding.
• Ground pin option to improve case grounding.
• High isolation between control and signal paths.
• Highly resistant to ESD.
ENVIRONMENTAL AND
PHYSICAL SPECIFICATIONS
Temperature
(Ambient)
Storage
–65°C to +125°C
Operating
–55°C to +85°C
Vibration
(General Note I)
10 g’s to 500 Hz
Shock
(General Note I)
30 g’s,
6ms half sine
Enclosure
Hermetically sealed
Weight
0.09 oz. (2.55g) max.
© 2011 TELEDYNE RELAYS
INTERNAL CONSTRUCTION
UNI-FRAME
UPPER
STATIONARY
CONTACT
ARMATURE
(800) 284-7007 • www.teledynerelays.com
MOVING
CONTACT
LOWER
STATIONARY
CONTACT
RF312/RF332 Page 1
RF312/RF332\092011\Q3
Series RF312/RF332
DPDT Non-Latching Electromechanical Relay
Signal Integrity up to 12Gbps,
SERIES RF312/RF332
TYPICAL RF CHARACTERISTICS (See RF Notes)
Isolation Across Contacts (RF Note 4)
Isolation Pole to Pole (RF Note 5)
0
0
-10
Pole-Pole Isolation (dB)
-10
Isolation (dB)
-20
-30
-40
-30
-40
-50
De-Energized
-60
Normally Open
-50
-20
Energized
Normally CLosed
-70
-60
-80
0
1000
2000
3000
4000
5000
6000
7000
8000
0
1000
2000
3000
Frequency (MHz)
Insertion Loss (RF Note 6)
5000
6000
7000
8000
VSWR (RF Note 6)
0
5
-0.5
4.5
-1
Normally CLosed
4
Normally Open
-1.5
3.5
-2
VSWR
Insertion Loss (dB)
4000
Frequency (MHz)
-2.5
-3
3
2.5
-3.5
2
Normally Closed
-4
Normally Open
1.5
-4.5
1
-5
0
1000
2000
3000
4000
5000
6000
7000
0
8000
1000
2000
3000
4000
5000
6000
7000
8000
Frequency (MHz)
Frequency (MHz)
RF312/RF332 Time Response (RF Note 6)
1.1
0.9
90%
Volt
0.7
37ps reference
0.5
62.3ps propagation delay time
0.3
51.3ps pulse rise time
10%
0.1
-0.1
-100
0
100
200
300
400
500
600
700
800
900
Time (ps)
RF NOTES
a. Fixture: .031" copper clad, reinforced PTFE, RT/duroid® 6002 with SMA connectors.
(RT/duroid® is a registered trademark of Rogers Corporation.)
b. Room ambient temperature.
c. Terminals not tested were terminated with 50-ohm load.
d. Contact signal level: –10 dBm.
e. No. of test samples: 4.
Data presented herein represents typical characteristics and is not intended for use as specification limits.
Data is per pole, except for pole-to-pole data.
Data is the average from readings taken on all open contacts.
Data is the average from readings taken on poles with coil energized and de-energized.
Data is the average from readings taken on all closed contacts.
Test fixture effect de-embedded from frequency and time response data.
1. Test conditions:
2.
3.
4.
5.
6.
7.
RF312/RF332 Page 2
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2011 TELEDYNE RELAYS
RF312/RF332\092011\Q3
Series RF312/RF332
DPDT Non-Latching Electromechanical Relay
Signal Integrity up to 12Gbps
SERIES RF312/RF332
GENERAL ELECTRICAL SPECIFICATIONS (@25°C)
Contact Arrangement
2 Form C (DPDT)
Rated Duty
Continuous
Contact Resistance
0.15 Ω max.
Contact Load Rating
Resistive: 1Amp/28Vdc
Low level: 10 to 50 μA @ 10 to 50 mV
Contact Life Ratings
10,000,000 cycles (typical) at low level
Coil Operating Power
RF312: 450 mW typical at nominal rated voltage
RF332: 200 mW typical at nominal rated voltage
Operate Time
RF312: 4.0 mS max.
RF332: 6.0 mS max.
Release Time
3.0 mS max.
Intercontact Capacitance
0.4 pf typical
Insulation Resistance
1,000 MΩ min. between mutually isolated terminals
Dielectric Strength
350 Vrms (60 Hz) @ atmospheric pressure
DETAILED ELECTRICAL SPECIFICATIONS (@25°C)
BASE PART NUMBERS (RF312)
RF312-5
RF312-12
5.0
12.0
Coil Resistance (Ohms ±20%)
50
390
Pick-up Voltage (Vdc max.)
3.6
9.0
RF332-5
RF332-12
Coil Voltage, Nominal (Vdc)
5.0
12.0
Coil Resistance (Ohms ±20%)
100
850
Pick-up Voltage (Vdc max.)
3.6
9.0
Coil Voltage, Nominal (Vdc)
BASE PART NUMBERS (RF332)
Teledyne Part Numbering System for RF312/RF332
RF312
X
-
5
/
S
R
Relay Series
Q = Solder-Coated Leads1
G = Gold-Plated Leads (RoHS Compliant)
R = RoHS Compliant Solder2
S = 0.187” Leads
No Suffix = 0.75” Leads
Ground Pin Option
(See Appendix A)
Nominal Coil Voltage
General Note: Parts ordered without suffix may be supplied with Solder-Coated or Gold-Plated leads
1
Parts ordered with Solder-Coated leads will have (Sn60/Pb40)
2
Parts ordered with RoHS Solder-Coated leads will have (Sn99.3/Cu0.7)
© 2011 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
RF312/RF332 Page 3
RF312/RF332\092011\Q3
Series RF312/RF332
DPDT Non-Latching Electromechanical Relay
Signal Integrity up to 12Gbps,
SERIES RF312/RF332
OUTLINE DIMENSIONS
.400 MAX
[ 10.16 ]
(RF332)
9
1
8
2
3
7
6
4
SCHEMATIC DIAGRAM
NOTES:
1. DIMENSIONS ARE IN INCHES, METRIC EQUIVALENTS SHOWN IN [ ].
2. POSTITIONS 5 AND 10 ARE FOR UNINSULATED CASE GROUND OPTIONS.
3. NO PROTRUSION BELOW BOTTOM OF HEADER WHEN GROUND PINS ARE INSTALLED
4. TO ORDER THE CASE GROUND OPTION, AFTER THE SERIES DESIGNATOR, ADD “Y” TO THE PART NUMBER FOR POSITION 5 OR “Z” TO THE PART
NUMBER FOR POSITION 10.
GENERAL NOTES
I. Relays will exhibit no contact chatter in excess of 10 μsec or transfer in excess of 1 μsec.
II. For reference only. Coil resistance not directly measureable at relay terminals due to internal series diode.
RF312/RF332 Page 4
SPECIFICATIONS ARE SUBJECT TO CHANGE WITHOUT NOTICE
© 2011 TELEDYNE RELAYS
RF312/RF332\092011\Q3
Series RF312/RF332
DPDT Non-Latching Electromechanical Relay
Signal Integrity up to 12Gbps
SERIES RF312/RF332
TYPICAL SIGNAL INTEGRITY CHARACTERISTICS
Normally Closed (Typ.)
+130 mV
0V
-130 mV
0 ps
40 ps
80 ps
120 ps
160 ps
Eye Height
Eye Width
SNR
JitterP-P
272.2 mV
92.62 ps
20.76
6.22 ps
Normally Open (Typ.)
+130 mV
0V
-130 mV
0 ps
40 ps
80 ps
120 ps
160 ps
Eye Height
Eye Width
SNR
JitterP-P
238.4 mV
92.82 ps
12.85
7.11 ps
PATTERN GENERATOR SETTINGS
•
•
•
•
•
10 Gbps Random Pulse Pattern Generator
231 - 1 PRBS signal
PRBS output of 300 mVP-P (nominal)
RF PCB effect (negligible) not removed from measurement
Data shown is typical of both poles
© 2011 TELEDYNE RELAYS
(800) 284-7007 • www.teledynerelays.com
RF312/RF332 Page 5
RF312/RF332\092011\Q3