Download PDF (2.9MB) - Updated 1/2015

Fast Bus
Fast Bus Busbar System
Contents
Fast Bus busbar adapter system
60 mm system
Page
Selection and ordering data
• Busbar holders
• Fast Bus adapter shoes
• Incoming supply terminals
• Copper busbar
• Busbar covers
• Other accessories
5/9
5/11
5/6
5/6
5/6
5/6
Overview
Introduction
Technical Data
Dimension drawings 5/2
5/3
5/3
5/10-5/15
FBCB Fast Bus circuit breakers
FBCB Fast Bus main and feeder
circuit breakers
Selection and ordering data
• Fast Bus circuit breakers assemblies and kits
• Fast Bus adapter shoes for VL breakers
Siemens Industry, Inc.
Industrial Controls Catalog
Fast Bus combination starters
Page
5/7
5/8
3RA1 Fast Bus combination starters
3RA2 Fast Bus combinations starters
3RA6 Fast Bus compact starters
Selection and ordering data
• See Section 4
5/1
Fast Bus
Fast Bus Busbar Adapter System
Overview
Busbar adapter systems
Busbar adapter systems
with busbar centerline spacing of 60 mm
60 mm busbar system
for sharp-edged copper busbars
to DIN 46 433,
width 20 mm to 30 mm,
thickness 5 mm and 10 mm
5/2
Page
Busbar holder
End and intermediate holders
for flat copper profiles
5/6
Fast Bus main circuit breakers 5/7
from 50 to 500A
Page
Fast Bus circuit breakers
from 15 to 600A
5/7
Page
Incoming supply terminals
5/6
3RA1 Combination Starters see
section 4
Siemens Industry, Inc.
Industrial Controls Catalog
Fast Bus
Fast Bus Busbar Adapter System
Introduction
General
Features
Benefits
The Fast Bus Multi-Motor Control system
is a 3-phase insulated busbar system
and is ideal for space saving in panel
designs. The system saves considerable
line side wiring and space for multi-motor
panels. It is also ideal for panels where
several feeder breakers are used and will
save significant wiring space and wiring
labor. The system is also ideal for future
expansion planning. when building
control panels. SIRIUS 3RV/3RT starter
combinations and Siemens circuit
breakers are all adaptable to Fast Bus for
convenient mounting and faster replacement times.
• Simple economical installation
• Saves installation time
• Compact design
• Reduces space requirements
• Requires fewer mounting holes
• Minimizes layout time
• Domestic and International approvals
• Allows flexibility for domestic and
export business
• Touch safe
• Protection for maintenance personnel
• Modular design
• Improves equipment mounting density
• Provision for system expansion
• Reduces time and costs associated
with system expansion
• Clip-on shoes provide mechanical
and electrical connections to panel
mounted busbars
• Reduces mounting and wiring time
and provides trouble free connections
• Main and Feeder breakers mount to
busbars
• Allows for quick retrofitting of breakers
Fast Bus is ideal for industrial applications where system availability is
important.
How to Select Fast Bus
1) Determine the required load.
2) Select method to power Fastbus.
—Main lug up to 800A
—Circuit breakers, 15A to 500A
If load exceeds 500A, the CB must be
separately panel mounted and fed to
a main lug infeed module.
3) Select 3RV MSP & 3RT contactor
components and appropriate adapter
shoe or select preassembled 3RA
starters. See section 4.
4) Select appropriate length busbar,
busbar holders, insulation covers
and any other required components.
General Ratings of Fastbus System
IEC
Domestic
Rated operating voltage
690V
600V
Rated insulation voltage, IEC VDE
AC 1000V
N/A
Temperature stability
Up to 105 degrees C
N/A
Busbar support and adapter shoe material
Glass-reinforced polyamide
Same
Color
RAL 7035, light gray
Same
Ampacity
Busbar thickness and width
362A
For technical information
on E and F frame circuit
breakers used as main
and feeder breakers, see
section 17
Thermal busbar currents, E-Cu, bare, at 35 °C ambient temperature in
accordance with DIN 43 6711
5 x 20 mm
3/16” x 3/4”
5 x 25 mm
3/16” x 1”
432A
5 x 30 mm
3/16” x 1 1/8”
500A
Busbar
dimensions
System
10 x 20 mm
3/8” x 3/4”
564A
mm
mm
20 x 5
25 x 5
30 x 5
60
60
60
274
327
379
362
432
500
430
513
595
20 x 10
30 x 10
60
60
427
573
564
756
670
900
10 x 25 mm
3/8” x 1”
660A
10 x 30 mm
3/8” x 1 1/8”
756A
720mm2
---
1400A
Siemens Industry, Inc.
Industrial Controls Catalog
Thermal current at
85 °C
65 °C
Busbar temperature
A
A
105 °C
A
5/3
Fast Bus
Fast Bus Busbar Adapter System
Introduction
Fast Bus set-up
The Fast Bus system is designed
to be easy to use and to save
set up time.
8US Busbar holders
The 8US busbar holders are
designed to accommodate
ampacities up to 1400A. In some
cases, the busbar holder will
accept busbars in either 5mm or
10mm widths. Refer to page 5/6
for selection details.
High quality material
Busbar supports and fuse bases
are manufactured from glassfiber reinforced, thermoplastic
polyester with the
color RAL 7035, light gray. The
material ensures excellent
mechanical, chemical and electrical properties. Furthermore,
the material has an extremely
low flammability and meets the
requirements of UL 94 V0.
8WC Busbar and
busbar systems
The most common size busbar
for applications in the US is the
8WC5053 (20 mm x 5 mm), however there are other styles available depending on your application.
Busbar systems with 60 mm busbar center-to-center clearance
have now become firmly established in the US market.
The permissible busbar temperature is a decisive factor when
dimensioning the busbars. The
busbar temperature is dependent on the current, the current
distribution, the busbar crosssection, the busbar surface, the
position of the busbar, the convection and the ambient temperature. The values stated in the
table on page 5/3 can only be
considered as reference values
because the conditions vary
with each location. The values
are based on constant current
over the whole busbar length.
The trend toward busbars
proves most advantageous
when the incoming supply is
centrally located and the load is
distributed symmetrically on
both sides.
For the assemblies of a busbar
system in the feeder circuit the
UL directives specify components with large clearance in air
and creepage distances (see
the table below). Components of
the 8US1 busbar system which
meet this requirement can be
found in this chapter.
Note:
The design of an 8US1 busbar
system for use in the feeder circuit always presumes the use of
the UL base plate (8US19 222UA01) so that the clearance in
air and creepage distance
requirements are met.
Clearance in air
Creepage distance
25.4 mm (1 inch)
50.8 mm (2 inch)
Between live parts and grounded, 25.4 mm (1 inch)
non-insulated metal parts
25.4 mm (1 inch)
Between live parts
5/4
Feeder/branch circuit
according to UL 508A
The feeder circuit is that part of
a circuit which comes in front of
the last short circuit protection
device (SCPD). The branch circuit is that part of the circuit
which follows after the last short
circuit protection device. When
the 8US1 busbar system is used
in a switchgear which must
comply with UL directives, it is
important to establish whether it
is to be used in the feeder circuit
or the branch circuit. Components used in the feeder circuit
require larger clearance in air
and creepage distances than in
the branch circuit.
Simple Fast Bus system
The two illustrations above show
the very basic items needed
when setting up a Fastbus system.
8US1 Busbar holder (5/6)
8US1 Ground busbar support
(shown attached however can be
mounted separately 5/6)
Short-circuit strength
The short-circuit strength of the
busbar system is dependent on
the spacing of the busbar holders and on the busbar crosssection.
The short-circuit strength of the
whole system is dependent on
the short-circuit strength of the
busbar system and the
components that are mounted
to the system.
Applications
The 8US Fast Bus distribution
system is ideal for control panel
builders with multiple motor
applications. These applications are most common in the
material handling, automotive,
food processing, pharmaceutical and paper processing
industries.
Ground busbar available in
5 x 20 mm to 10 x 30 mm
8WC Busbar (8WC5053
shown) FBB36 Busbar (5/6)
Siemens Industry, Inc.
Industrial Controls Catalog
Fast Bus
Fast Bus Busbar Adapter System
Introduction
Fast Bus combination starters and group installation assemblies
Ratings for Group Installations per
NEC 430-53
Standard Installation, NEC 430-52
Group Installation, NEC 430-53
Group Installation is an approach to building multiple motor control systems in
accordance with Section 430-53 of the
National Electrical Code. In Group installation, multiple motor starters can be
grouped under one short circuit protective
device. The 3RV MSP’s have been UL
listed for use in Group Installations both
with and without 3RT contactors when
mounted on the Fast Bus system. A 3RT
contactor is added when remote operation of the motor is required.
MSP
Type
FLA
Amp
Range
FLA
Amp
Range
3RV201
3RV201
3RV202
3RV202
3RV202
3RV202
3RV103
3RV104
S00
S00
S0
S0
S0
S0
S2
S3
0.11-12.5
0.11-16
3.5-12.5
3.5-25
28-32
36-40
11-50
28-100
The selection of components for
Group Installation is a simple process of the following three steps:
1. Selection of the Branch Circuit Protective Device, fuse or circuit
breaker.
2. Selection of the 3RA Motor Starter
based on the motor Full Load Amps.
Maximum rating of Group Branch
Circuit Protective Device
Short Circuit
Fuse
Circuit Breaker
The main fuse should
be selected based on
the FUSE selection
procedure listed below.
The main CB should be
selected based on the
CIRCUIT BREAKER
selection procedure
listed below.
Circuit Breaker Selection
Select a circuit breaker (CB) between:
Minimum CB size (per NEC430-110):
Sum of all motor FLC (per NEC table
430-150) x115%.
Maximum CB size (per NEC430-53c):
250% x FLC of the largest motor +
FLC of all other motors.
Current Ratings 1) 2)
240V 480V 600V
65kA
65kA
65kA
65kA
65kA
65kA
65kA
65kA
—
65kA
—
65kA
50kA
12kA
65kA
65kA
30kA
—
30kA
—
—
—
25kA
30kA
Fuse Selection
Calculate the maximum fuse size per
NEC430-53c.
Max Fuse Size =175% x FLC of largest motor + FLC of all other motors
(FLC’s from NEC table 430-150).
Short Circuit
Current Ratings (Type E) 1 )
Assembled
Starter
Type
Starter
Frame
Size
FLA
Amp
Range
240V
480Y/277V
600Y/347V
3RA201
3RA201
3RA202
3RA202
3RA202
3RA103
3RA104
3RA104
S00
S00
S0
S0
S0
S2
S3
S3
0.11-12.5
0.11-16
0.45-12.5
0.45-25
28-32
11-50
28-75
28-100
—
65kA
—
65kA
50kA
65kA
—
65kA
—
65kA
—
65kA
50kA
65kA
—
65kA
30kA
—
30kA
—
—
25kA
30kA
—
Branch Circuit Protective Device for 480V-Ratings: The appropriate BCPD need to be determined in accordance with the National Electrical Code, Article 430-53 and the
application. The following devices are permitted:
Fuses: Classes RK1, RK5, J, G, T, CC or Circuit breakers: Listed Siemens type, with a marked short-circuit rating equal or larger than the available short-circuit
current rating. These devices were tested for group installation use at the above levels without any upstream branch circuit device.
2) 3RA2 used as Manual Motor Controller; Branch Circuit Protective Device for 600V-Ratings: Max. Class J 50A
3) Starter sizes S00,S0 and S3 require additional type E line side terminal adaptors on the MSP for type F applications. See section 1 accessories
1)
Siemens Industry, Inc.
Industrial Controls Catalog
5/5
Fast Bus
• Revised •
09/30/14
Fast Bus Busbar Adapter System
60 mm system
Selection and ordering data
Busbar holder
Insulating Base Plate
Busbar 3-phase
End cover
Busbar holder
Insulating Base Plate
End cover
Busbar 3-phase
Busbar Neuteral or PE
Ground busbar holder
Terminals for Round
Conductors
Busbar Neuteral or PE
Terminals for Round
Conductors
Description
8US1922-2UA01
8WC5
8US1948-2AA00
Base plate
3-pole system flat
Copper Busbar with tin plating
20 mm x 5 mm x 914 mm (36”)
20 mm x 5 mm x 1524 mm (60”)
20 mm x 5 mm x 2000 mm (78.74”)
25 mm x 5 mm x 2000 mm (78.74”)
30 mm x 5 mm x 2000 mm (78.74”)
20 mm x 10 mm x 2000 mm (78.74")
30 mm x 10 mm x 2000 mm (78.74")
720 mm2 x 2400 mm (94.49”)
UL Current
rating
230 mm x 1100 mm
for 60 mm systems
for 60 mm systems
for 60 mm systems
for 60 mm systems 4)
for 60 mm systems
for 60 mm systems
for 60 mm systems
Twin T (TT) Busbar
—
362A
362A
362A
432A
500A
564A
756A
1400A
Busbar holder (end and intermediate)
3-pole with inside mounting
for 20 mm and 30 mm x 5 mm or 10 mm —
3-pole with inside mounting
for 25mm x 5mm or x 10mm
—
8US1923-3UA01 3-pole with inside mounting
for Twin T (TT) w/ end cover
—
8US1922-1AC00
8US1923-1AA01
8US1922-2AA00
UL508A
Order No.
Compliance1)
required
8US19 22-2UA01
FBB36
3 pcs
FBB60
3 pcs
8WC5053
8WC5054
8WC5055
8WC5063
8WC5065
8US19 48-2AA00
yes
—
yes
8US19 23-3UA01
8US19 23-3AA00
8US19 43-3AA01
Busbar holder end cover
3-pole end cover
fits 8US19 23-3UA01 and 8US1923-3AA01
required
Ground Busbar holder
1-pole with inside mounting
8US19 22-1AC00
for 20 mm - 30 mm x 5 mm or 10 mm2)
n/a
8US19 23-1AA01
Cover profiles for Busbars
for 5 mm busbars up to 30 mm wide
for 10 mm busbas up to 30 mm
for Twin T (TT) busbar
1000 mm length
1000 mm length
1000 mm length
required
required
required
8US19 22-2AA00
8US19 22-2BA00
8US19 22-2DA00
—
—
—
required
required
required
8US1922-2EA00 4 pcs
8US1922-2EA01 8 pcs
8US1922-2EB00
80A
300A
440A
yes
yes
yes
560A
560A
yes
yes
800A
yes
5SH3538
8US19 21-1BA00
8US19 21-1AA00
FBT600F
8US19 41-2AA03
8US19 41-2AA04
—
yes
8US19 22-1GC00
Reserve Space Cover (for covering round terminals placed on 3-phase
Holder for reserve space cover
32mm height
Holder for reserve space cover
107 mm length
Reserve space cover
195mm height / 700mm length
Feeder Lugs (mounts to all busbar sizes on this page)
3-pole terminal plate with cover
20 mm x 200 mm 16-4 AWG
3-pole terminal plate with cover
54 mm x 200 mm 10-2/0 AWG
3-pole terminal plate with cover
81 mm x 200 mm 2 AWG-250 MCM
3-pole terminal plate with cover
180 mm x 200 mm 250-600 MCM
3-pole terminal plate
154 mm x 184 mm 300-600 MCM
5SH3538
160 mm x 184 mm for flat bars up to
8US1921-1BA00 3-pole terminal plate
32 mm x 20 mm
Cover for 8US19 41-2AA03 and 04
5/6
Pack
Units
yes
yes
yes
yes
yes
yes
yes
yes
—
—
—
busbar)
8US1922-2EB00
FBT600F w/cover
Ground
busbar
holder
180 mm x 200 mm x 90 mm
1) UL 508A labeled panels require the use of components that meet the creepage and air distances of 1” air clearance and 2” creepage
distance. N/A = not applicable for given item.
2) Current rating dependent on size of busbar used. Refer to busbar selection data.
Product Category: IEC
Siemens Industry, Inc.
Industrial Controls Catalog
Fast Bus
Fast Bus Busbar Adapter System
60 mm system
Circuit breaker assemblies and kits
Selection and ordering data
Description
FBCB Fast Bus circuit breakers
Offer a full range of feeder circuit breakers from 15A to 250A. All kits 125A and
under are pre-assembled on 60 mm
Fast Bus adaptor shoes and ready to
place on the busbar. Circuit breakers
150A and higher are pre-packaged kits
for fast user assembly and must be
torqued down to the busbar prior to
assembly. For VL breakers, adaptors
are available for up to 500A breakers
(both main and feeder orientation).
See page 5/8.
Available in 2014 2)
Design
3 pole/600V fully assembled breakers and
adaptors that quickly snap onto the Busbar.
15A
20A
25A
30A
35A
40A
45A
50A
60A
70A
80A
90A
100A
110A
125A
FBCB100
3 pole/600V kitted components for customer
assembly that require the adaptor to be torqued
down to the Busbars prior to assembly.
Design
Breaker Frame (SCCR Rating
UL Current Rating
Feeders Circuit Breakers
150A
175A
200A
225A
250A
ED (25kA)
HHED (65kA)
FBCB015
FBCB020
FBCB025
FBCB030
FBCB035
FBCB040
FBCB045
FBCB050
FBCB060
FBCB070
FBCB080
FBCB090
FBCB100
FBCB110
FBCB125
—
FBCB020H
FBCB025H
FBCB030H
FBCB035H
FBCB040H
FBCB045H
FBCB050H
—
—
—
—
—
—
—
—
—
—
—
—
3 pole/600V kitted components for customer
assembly that require the adaptor to be torqued
down to the Busbars prior to assembly.
100A
125A
150A
175A
200A
225A
250A
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
NGG (25kA)
FBCB015NGG
FBCB020NGG
FBCB025NGG
FBCB030NGG
FBCB035NGG
FBCB040NGG
FBCB045NGG
FBCB050NGG
FBCB060NGG
FBCB070NGG
FBCB080NGG
FBCB090NGG
FBCB100NGG
FBCB110NGG
FBCB125NGG
FBCB150
FBCB175
FBCB200
FBCB225
FBCB250
—
—
—
—
—
HGG (35kA)
FBCB015HGG
FBCB020HGG
FBCB025HGG
FBCB030HGG
FBCB035HGG
FBCB040HGG
FBCB045HGG
FBCB050HGG
FBCB060HGG
FBCB070HGG
FBCB080HGG
FBCB090HGG
FBCB100HGG
FBCB110HGG
FBCB125HGG
LGG (65kA)
FBCB015LGG
FBCB020LGG
FBCB025LGG
FBCB030LGG
FBCB035LGG
FBCB040LGG
FBCB045LGG
FBCB050LGG
FBCB060LGG
FBCB070LGG
FBCB080LGG
FBCB090LGG
FBCB100LGG
FBCB110LGG
FBCB125LGG
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
—
Breaker Frame (SCCR Rating)
UL Current Rating
Main Circuit Breakers
FXD (65kA)
1))
FXD (65kA)
HFXD (65kA)
FBCB100M
FBCB125M
FBCB150M
FBCB175M
FBCB200M
FBCB225M
FBCB250M
FBCB100M-HB
FBCB125M-HB
FBCB150M-HB
FBCB175M-HB
FBCB200M-HB
FBCB225M-HB
FBCB250M-HB
—
—
—
—
—
—
—
—
—
—
—
—
—
—
FBCB250M
1) UL Short Circuit Current ratings are based on 480V. Contact Siemens for 600 V ratings.
2) Check Industry Mall for availability.
Siemens Industry, Inc.
Industrial Controls Catalog
Product Category: IEC
5/7
Fast Bus
Fast Bus Busbar Adapter System
60 mm system
Busbar adapters and device holders
Selection and ordering data
Busbar
device
adapters
Adapter Adapter Rated UL508A1)
Number Rated Conof mount- current necting length width
voltage compliance
ing rails
cables
UL
(35 mm)
A
AWG
mm
mm
V
Order No.
Pack
units
Weight
per PU
approx
.
kg
For SIRIUS
Size S00/S0
8US12 51-5DM07
MSP’s
1
25
12
182
45
600
yes
Contactors
+ Overload relays
1
25
12
182
45
600
yes
8US12 51-5DM07
0.183
0.183
Direct start load
feeders
1
25
12
182
45
600
yes
8US12 51-5DM07
0.183
Busbar adapters
1
25
12
182
45
600
yes
8US12 51-5DM07
0.183
+ Device holders
1
--
--
182
45
600
yes
+ Connecting
plates
--
--
--
--
--
--
yes
8US19 98-1AA00
1
12
14
182
45
600
yes
8US12 51-5CM47
0.190
8US12 61-5FM08
0.263
Reversing feeders
8US21 51-5DM07
Size S00/S0
Cage Clamp
Direct start load
feeders
Size S2
8US21 60-5AM00
8US12 50-5AM00
0.158
100 units
0.100
MSP’s
1
50
8
182
55
600
vyes
Contactors
+ Overload relays
1
50
8
182
55
600
yes
8US12 61-5FM08
0.263
Direct start load
feeders
1
50
8
245
55
600
yes
8US12 61-5FP08
0.292
Busbar adapters
1
50
8
242
55
600
yes
8US12 61-5FP08
0.292
Busbar adapters
1
--
--
242
55
600
yes
+ Device holders
--
--
--
242
55
600
yes
+ Connecting
plates
--
--
--
--
--
--
yes
8US19 98-1AA00
80
4
215
72
600
yes
8US12 11-4TR00
1
100
--
200
72
600
yes
--
100
--
200
72
600
yes
FBS100722
0.610
Reversing feeders
Size S3
8US12 60-5AM00
0.202
8US12 60-5AP00
0.243
100 units
FBS100723R
0.100
0.659
0.590
8US12 11-4TR00
For VL UL circuit breakers 2)
8US12 13-4AQ03
VL150 UL,
DG frame
--
150
Tubular 190
contacts
105
600
yes
8US12 13-4AQ03
1.020
VL250 UL,
FG frame
--
250
Tubular 190
contacts
105
600
yes
8US12 13-4AQ03
1.020
VL400 UL,
JG frame
--
400
Tubular 296
contacts
140
600
yes
8US12 13-4AH00
1.900
--
540 3)
296
140
600
yes
8US12 13-4AH00
1.900
VL400X UL,
LG frame
Tubular
contacts
8US12 13-4AH00
1)
UL 508A labeled panels require the use of components that meet the creepage and air distances of 1” air clearance and 2” creepage distance.
N/A = not applicable for given item.
2)
For use with 10mm x 30mm and twin T (TT) busbars only. Adaptors can be configured for main or feeder breakers applications.
3)
For use with maximum 500A circuit breaker. Circuit breakers greater than 500A must be panel mounted off the busbar system and fed to the busbars
via an infeed module. See page 5/6.
5/8
Product Category: IEC
Siemens Industry, Inc.
Industrial
Controls Catalog
* You can order this quantity or a multiple
thereof.
Fast Bus
• Revised •
09/30/14
Fast Bus Busbar Adapter System
60 mm system
Terminals and accessories
Selection and ordering data
Description
Max
Amps
Width
UL508A
Order No.
Compliance1)
List
Pack
Price $ Units
Terminals for round conductors
Terminals
5 mm busbar thickness 3)
12 mm x 5 mm
15 mm x 5 mm
20 mm x 5 mm
25 mm x 5 mm
30 mm x 5 mm
20 mm x 5 mm, 25 mm x 5 mm
30 mm x 5 mm
10 mm bar thickness
12 mm x 10 mm3)
15 mm x 10 mm3), 20 mm x 10 mm
25 mm x 10 mm, 30 mm x 10 mm
Terminals
20 mm x 10 mm, 25 mm x 10 mm
30 mm x 10 mm
180
270
400
440
180
270
400
440
500
600
16 - 6 AWG
12 - 2 AWG
6 - 2/0 AWG
6 - 250 MCM
16 - 6 AWG
12 - 2 AWG
6 - 2/0 AWG
6 - 250 MCM
3/0 - 350 MCM
300 - 600 MCM
8US19 21-2AA00
8US19 21-2AB00
8US19 21-2AD00
8US19 21-2AC00
8US19 21-2AA01
8US19 21-2AB01
8US19 21-2AD01
8US19 21-2AC01
8US19 41-2AA01
8US19 41-2AA02
100
50
50
50
15
15
15
15
6
3
180
270
400
440
180
270
400
440
500
600
16 - 6 AWG
12 - 2 AWG
6 - 2/0 AWG
6 - 250 MCM
16 - 6 AWG
12 - 2 AWG
6 - 2/0 AWG
6 - 250 MCM
3/0 - 600 MCM
300 - 600 MCM
8US19 21-2BA00
8US19 21-2BB00
8US19 21-2BD00
8US19 21-2BC00
8US19 21-2BA01
8US19 21-2BB01
8US19 21-2BD01
8US19 21-2BC01
8US19 41-2AA01
8US19 41-2AA02
100
50
50
50
15
15
15
15
6
3
8US19 22-1GA00
10
8US19 22-1GA02
1
Terminal covers for circular conductors (mounts to busbars)
For terminals up to 250 MCM
200 mm long, 84 mm wide
For terminals up to 600 MCM
200 mm long, 270 mm wide
8US19 22-1GA00
For terminals up to 600 MCM
200 mm long, 135 mm wide
Accessories for busbar adapters and device holders
Mounting Rail
8US1998-1BA00
FBC20
FBC135
Mounting rail (35 mm) - plastic
complete with mounting screws
45 mm
55 mm
70 mm
90 mm
110 mm
n/a
n/a
n/a
n/a
n/a
8US1998-7CA15
8US1998-7CA16
8US1998-4AA00
8US1998-7CA08
8US1998-7CA10
10
10
10
10
10
Connection holder
(for vertical bubar assembly)
fixes the MSP to the mounting rail 3) (for SIRIUS sizes S00/S0)
-
n/a
8US1998-1DA00
20
Screw holder
for supplementary screw fixing of the feeder
(for SIRIUS sizes S00/S0)
-
n/a
8US1998-1CA00
20
Spacer
fixes the busbar adapter to the device holder
(for SIRIUS sizes S00/S0)
-
n/a
n/a
8US1998-1BA00
8US1998-1BA01
100
1
Connection wedges
for mechanical linking of adapters and switching device holders
(2 units required per combination)
-
n/a
FBC20
20
45 mm
54 mm
n/a
n/a
8US1998-8AM07
8US1998-8AA10
182 mm 10 mm
200 mm 9 mm
n/a
n/a
8US1998-2BM00
8US1998-2BJ10
Outgoing terminal rail for busbar adapters
Load Side
Terminal
Plug-type terminal
(complete with supporting element for attaching to busbar adapter
and switching device holder. Spring loaded terminals.)
3 x 14 AWG (400 V) and 4 x 16AWG (250 V)
7 x 14 AWG (400 V)
Accessories for busbar adapters and device holders
Side module for busbar adapter expansion For adapters w/182 mm
Side module for busbar adapter expansion For adapters w/200 mm
91 mm
91 mm
8US1998-2BM00
1)
UL508A labeled panels require the use of components that meet the creepage and air distances of 1” air clearance and 2” creepage distance.
N/A = not applicable for given item.
Terminals must be manually spaced on the busbar to comply with UL508A distances of 1” air clearance and 2” creepage distance.
3) Cannot be used on Twin T (TT) profile up to 1400 A.
2)
Siemens Industry, Inc.
Industrial Controls Catalog
Product Category: IEC
5/9
Fast Bus
Fast Bus Busbar Adapter System
60 mm system
Dimension drawings
8US19 23-3UA01
31
5
0.187
(5)
36 (914)
FBB60
60 (1524)
NSE0_02058
A
FBB36
40
112
40
01573
40
209
120
75
50
L3
123
51
Support for blanking covers,
8US1922-2EA00
8US19 22-1AC00 with 8US19 23-3UA01
8US19 22-1AC00 with 8US19 23-3AA01
30
32
60
40
10
L2
L3
25
Copper Busbar/TT profile, 8US19 48-2AA00
6
L1
NSE0_02071
2
L
166
0.75
(20)
Dimension
25
L1
185
A
8US19 43-3AA00
31
FBB36/FBB60 Copper Busbar
200
10
6
NSE0_02073
NSE0_02070
9
8US19 22-2BA00
8US19 22-2AA00
30,5
NSE0_00720
30,5
Length 1000 mm
Blanking cover, 8US1922-2EB00
NSE0_00721
10,2
5,2
8US19 23-1AA01
49,4
62,5
Length 1000 mm
40
5/10
60
NSE0_02072
1,5
71
78
NSE0_01607
34
31
200
8US19 22-2DA00
62,5
Siemens Industry, Inc.
Industrial Controls Catalog
Fast Bus
Fast Bus Busbar Adapter System
60 mm system
Dimension drawings
Infeed, 8US19 21-1BA00
Infeed, 8US19 41-2AA03
28
2
32
96
36
NSE0_02074
NSE0_02060
54
156
184
60
200
194
60
94
50
21
154
88
Infeed, 8US19 21-1AA00
72
100
Infeed, 8US19 41-2AA04
5
28,7
81
32
88
28
NSE0_02059
NSE0_02053
60
148
184
194
200
60
94
50
72
100,2
FBT600F Cover
FBT600F (supplied with cover)
Infeed 5SH3538
8,8
160
88
34
166
I2_13999a
60
194
200
60
146
20
28
32
180
Siemens Industry, Inc.
Industrial Controls Catalog
5/11
Fast Bus
Fast Bus Busbar Adapter System
60 mm system
Dimension drawings
Busbar device adapter, 8US12 50-5AM00
Busbar device adapter, 8US12 60-5AP00
60
6
5
20
5
NSE0_02051
60
10
242
182
3,4
23,7
47,4
53,8
Busbar device adapter, 8US12 61-5FM08
51,7
Busbar device adapter, 8US12 11-4TR00
40
60
Ø
2,
23,7
60,2
26,5
54,5
41
60
72
8,5
Busbar device adapter, 8US12 61-5FP08
60
6
20
148
53
242
182
60
182
5
5
5
NSE0_02063
20
5
6
48
170
12
10
Busbar device adapter, 8US12 51-5DM07
,4
60
47,4
54
2,9
,4
Ø3
5
NSE0_02068
60
182
5
214
200
164
60
60
NSE0_02062
20
5
6
68
148
12
5
10
60
Ø3
5/12
2,5
29,5
36
45
23,7
60,2
8,5
NSE0_02061
,5
Ø3
47,4
54
23,7
60,2
8,5
Siemens Industry, Inc.
Industrial Controls Catalog
Fast Bus
Fast Bus Busbar Adapter System
60 mm system
Dimension drawings
Busbar device adapter, 8US12 51-5CM47
114,5
114,5
190
60
23
31,5
38,8
Busbar device adapter, 8US12 13-4AQ01
35
105
NSE0_02066
182
64
3
NSE0_02069
131,5
131,5
190
60
35,5
26,8
23
Busbar device adapter, 8US12 13-4AQ03
8US19 98-2BM00
14
32
42
14
35
105
NSE0_02065
270
296
247,5
60
56
24
Busbar device adapter, 8US12 13-4AH00
45
140
Siemens Industry, Inc.
Industrial Controls Catalog
NSE0_02067
55
5/13
Fast Bus
Fast Bus Busbar Adapter System
60 mm system
Dimension drawings
8US1941-2AA01
a
b
c
d
e
f
8US1921-2AA0.
8US1921-2AB0.
8US1921-2AC0.
8US1921-2AD0.
7.5
10.5
17
14.5
11.5
15.5
23.5
20.5
22.5
29
36
32
25
35
55
42
5
5
5
5
10
10
12
12
4 Nm
6 Nm
15 Nm
10 Nm
10mm 8US1921-2BA0.
8US1921-2BB0.
8US1921-2BC0.
8US1921-2BD0.
7.5
10.5
17
14.5
11.5
15.5
23.5
20.5
22.5
29
36
32
25
35
55
42
10
10
10
10
10
10
12
12
4 Nm
6 Nm
15 Nm
10 Nm
85,5
Max tighening torque
max. 98
Type
5mm
51
43
40
8US1941-2AA02
8US1921-2A / -2B
max. 84
42
max. 86
51
43
8US1922-1GA00
194
200
60
189
60
FBC135
31
38
84
10 32
35
55
8US19 22-1GA02
5/14
Siemens Industry, Inc.
Industrial Controls Catalog
Fast Bus
Fast Bus Busbar Adapter System
60 mm system
Dimension drawings
8US19 98-1DA00
8US19 98-4AA00
8US19 98-7CA08
29
8US19 98-7CA10
8US19 98-7CA15
8US19 98-8AM07
8US19 98-1CA00
Siemens Industry, Inc.
Industrial Controls Catalog
8US19 98-7CA16
7
29
74
90
NSE0_01599
35
27
8US19 98-1CA00
9
14
8US19 98-1BA00
8US19 98-8AA10
8US19 98-1DA00
5/15
Fast Bus
Combination
& Starters
SIRIUS 3RA Fast BusStarters
Combination
Startersfor
andGroup
GroupInstallation
Installation Assemblies
SIRIUS 3RA2 Motor Starters
General data
General data
Order No. scheme
Digit of the Order No.
SIRIUS starters
1st 3rd
4th 5th 6th 7th
@@@
@
3RA
SIRIUS 2nd generation
Type of starter (direct-on-line starter = 1,
reversing starter = 2)
2
@
0
@
8th 9th 10th 11th 12th
–
@
@
@
@
@
@
@
@
@
13th 14th 15th 16th
–
@
@
@
@
@
@
K
6
@
Size (S00 = 1, S0 = 2)
@
Setting range for overload release
Design type and connection method
@
Rated power at 460 V AC
Integrated auxiliary switches of the contactor
@
Operating range / solenoid coil circuit (contactor)
Rated control supply voltage (contactor)
Example
@
3RA
2
1
1
0
–
0
B
A
1
5
–
1
A
Note:
The Order No. scheme is presented here merely for information purposes and for better understanding of the logic behind the order
numbers. For your orders, please use the order numbers quote in the catalog in the Selection and ordering data.
Technical specifications
Direct-on-line starters/
reversing starters
Size
Connection methods Mounting
Control voltage
Width W
Height H
Depth D
mm
mm
mm
Mounting dimensions
S00
3RA21 1.
Screw terminals
Standard mounting rails
AC/DC
45
167
97
Busbar adapters
AC/DC
45
200
155
AC/DC
45
198
97
Busbar adapters
AC/DC
45
260
155
Standard mounting rails
AC
45
193
97
DC
45
193
107
AC
45
260
155
DC
45
260
165
AC/DC
45
243
107
Busbar adapters
AC/DC
45
260
165
Standard mounting rails
AC/DC
90
170
97
Busbar adapters
AC/DC
90
200
155
AC/DC
90
204
97
Busbar adapters
AC/DC
90
260
155
Standard mounting rail
adapters
AC
90
265
120.3
DC
90
265
130
Busbar adapters
AC
90
260
155
DC
90
260
165
AC/DC
90
270
131
AC/DC
90
260
165
Spring-type terminals Standard mounting rails
Busbar adapters
6
W
Screw terminals
D
H
S0
3RA21 2.
Spring-type terminals Standard mounting rails
Reversing starters
3RA22.
S00
3RA22 1.
Screw terminals
Spring-type terminals Standard mounting rails
S0
3RA22 2.
Screw terminals
Spring-type terminals Standard mounting rail
adapters
Busbar adapters
Type
Size
Number of poles
3RA2. 1
S00
3
Mechanics and environment
Permissible ambient temperature
• During operation
• Storage and transport
°C
°C
-20 ... +60
-55 ... +80
Weight
kg
0.6 ... 1.5
Permissible mounting
positions
0.8 ... 2.3
22
9
Shock resistance
(sine-wave pulse)
Acc. to IEC 60086 Part 2-27
Degree of protection
Acc. to IEC 60947-1
5/16
6/10
3RA2. 2
S0
3
SIRIUS Innovations Supplement 2012
g
9
22
3 9
Direct-on-line starters
3RA21.
Important: Acc. to DIN 43602 start command "I" at the right or top
Up to 6
Up to 6
IP20
Siemens Industry, Inc.
Industrial Controls Catalog
Combination Starters & Starters for Group Installation
SIRIUS 3RA Motor Starters
General data
Direct-on-line starting • For 60 mm busbar systems • Sizes S00 and S0
60 mm busbar adapter
for screw terminals
8US12 51-5DS10 for S00
8US12 51-5NT10 for S0
Motor starter protector
Size S00/S0
Screw terminals
Link module
3RA19 21-1DA00 for S00
3RA29 21-1AA00 for S0, AC contactor
3RA29 21-1BA00 for S0, DC contactor
Contactor
Size S00/S0
Screw terminals
Left: 3RA21 motor starter for direct-on-line starting with busbar
adapters with screw connection
60 mm busbar adapter
for spring-type terminals
8US12 51-5DT11 for S00
8US12 51-5NT11 for S0
Motor starter protector
Size S00/S0
Spring-type terminals
Link module
3RA29 11-2AA00 for S00
3RA29 21-2AA00 for S0 1)
Contactor
Size S00/S0
Spring-type terminals
1) Additional
3RA29 11-1CA00
spacer for height compensation
on AC contactors size S0 with
spring-type terminals.
Right: 3RA21 motor starter for direct-on-line starting with busbar
adapters with spring-type connection
3RV104 with 3RT104
3RV103 with 3RT103
Adapter Shoe
8US1261-5FP08
MSP
3RV103
Link Module
for AC: 3RA1931-1A
for DC: 3RA1931-1B
Contactor
3RT103
NSB0_02091a
Adapter Shoe
8US1211-4TR00
MSP
3RV104
Link Module
for AC: 3RA1941-1A
for DC: 3RA1941-1B
Contactor
3RT104
Bracket
FBS0 070B
Siemens Industry, Inc.
Industrial Controls Catalog
5/17
Fast Bus
SIRIUS 3RA Fast Bus Combination Starters and Group Installation Assemblies
Selection
Reversing duty • For 60 mm busbar systems • Sizes S00 and S0
RS assembly kit for reversing duty and
busbar mounting
Screw connection:
3RA29 13-1DB1 for S00
3RA29 23-1DB1 for S0
For spring-type connection:
3RA29 13-1DB2 for S00
3RA29 23-1DB2 for S0 1)
Comprising:
1 wiring kit
1 busbar adapter
1 device holder
2 connecting wedges
1)
60 mm busbar adapter
For screw terminals:
8US12 51-5DS10 for S00
8US12 51-5NT10 for S0
For spring-type terminals:
8US12 51-5DT11 for S00
8US12 51-5NT11 for S0
Also includes 3RA29 11-1CA00 spacer
for height compensation on AC contactors
size S0 with spring-type terminals.
Motor starter protector
Size S00/S0
Screw terminals/
spring-type terminals
2 connecting wedges
8US19 98-1AA00
Link module
For screw terminals:
3RA19 21-1DA00 for S00
3RA29 21-1AA00 for S0, AC contactor
3RA29 21-1BA00 for S0, DC contactor
For spring-type terminals:
3RA29 11-2AA00 for S00
2)
3RA29 21-2AA00 for S0
60 mm device holder
8US12 51-5AS10
1
NSB0_02094b
3
2 contactors
Size S00/S0
Screw terminals/
spring-type terminals
4
2
2)
Additional 3RA29 11-1CA00 spacer
for height compensation on AC contactors
size S0 with spring-type terminals.
Wiring kit
Screw connection:
3RA29 13-2AA1 for S00
3RA29 23-2AA1 for S0
Spring-type connection:
3RA29 13-2AA2 for S00
3RA29 23-2AA2 for S0
1 Upper wiring module
2 Lower wiring module
3 2 connecting clips
4 Mechanical interlock
(can be removed if necessary)
3RA22 motor starter for reversing duty and 60 mm standard mounting rail in size S00/S0
(the version with screw connection is shown in the picture)
5/18
Siemens Industry, Inc.
Industrial Controls Catalog
Fast Bus
SIRIUS 3RA Fast Bus Combination Starters and Group Installation Assemblies
Selection
Required Components for Fast Bus Mounting
3RV103 with Reversing 3RT103
a Link Module
MSP
3RV103
for AC: 3RA1931-1A
for DC: 3RA1931-1B
b Mechanical Interlock
3RA1924-2B
c Fast Clips
FBC20
Contactor Support
8US1260-5AP00
(without DIN rail) and
with 8US1998-2BM00
Adapter Shoe
8US1261-5FP08
2 Contactors
3RT103
3RA1933-2A
Wiring Kit
u
a Upper Wiring Module
u
b Lower Wiring module
3RV104 with Reversing 3RT104
a Link Module
for AC: 3RA1941-1A
for DC: 3RA1941-1B
Adapter Shoe
8US1211-4TR00
b Mechanical Interlock
3RA1924-2B
MSP
3RV104
a
3RA1943-2A
Wiring Kit
u
a Upper Wiring Module
u
b Lower Wiring Module
u
a
b
2 Contactors
3RT104
2 Brackets
FBS0070B
u
b
Siemens Industry, Inc.
Industrial Controls Catalog
5/19
Fast Bus
SIRIUS 3RA Fast Bus Combination Starters and Group Installation Assemblies
Dimensions
Dimensions, 3RV101 with 3RT101
3RA2110
Fast Bus Non-reversing
45
154.9
5
96.9
200
169.9
49
45
3RA2210
Fast Bus Reversing
1) Lockable in OFF position. Padlock diameter 5 mm.
2) When a front auxiliary is installed on the contactor,
add 44 mm to the depth of the contactor.
Dimensions, 3RV102 with 3RT101
3RA2210-0.A1.-2AP0
Alle Bemassungswerte sind in Millimeter (mm) angegeben.
All dimensions are in millimeters (mm)
3RA2120
3RA2110-0.D1.-1AP0
Fast Bus Non-reversing
Format/Size: DIN A4
5
Massstab/Scale:
1:2
97
96.9
193.4
49
45
3RA2220
Fast Bus Reversing
1) Lockable in OFF position. Padlock diameter 5 mm.
2) When a front mount auxiliary is installed on the
contactor, add 44 mm to the depth of the contactor.
All dimensions shown in millimeters. For reference
purposes only. Not to be used for design or construction purposes.
3RA2120-1.A24-0AP0
5/20
Siemens Industry, Inc.
Industrial Controls Catalog
Fast Bus
SIRIUS 3RA Fast Bus Combination Starters and Group Installation Assemblies
Dimensions
3RV103 with 3RT103
3RA1230
Fast Bus Reversing
3RA1130
Fast Bus Non-reversing
1)
2)
SIEMENS
53
14
34
1)
2)
259
309
259
309
SIEMENS
SIEMENS
3)
SIEMENS
NSK-8175
NSK-8174
SIEMENS
7
10
18
17
55
18
28
68
95
142
DC 157
176
10
17.5
120
10
Lateral clearance to grounded components minimum 6 mm.
1) Arcing space
2) Lockable in OFF position with padlock diameter 5 mm.
3) When a front mount auxiliary is installed on the
contactor, add 49 mm to the depth of the contactor.
All dimensions shown in millimeters. For reference
purposes only. Not to be used for design or construction purposes.
Siemens Industry, Inc.
Industrial Controls Catalog
5/21
Fast Bus
SIRIUS 3RA Fast Bus Combination Starters and Group Installation Assemblies
Dimensions
3RV104 with 3RT104
Lateral clearance to grounded components minimum 6 mm.
1) Arcing space
2) Lockable in OFF position with padlock diameter 5 mm.
3) When a front mount auxiliary is installed on the
contactor, add 49 mm to the depth of the contactor.
All dimensions shown in millimeters. For reference
purposes only. Not to be used for design or construction purposes.
5/22
Siemens Industry, Inc.
Industrial Controls Catalog