SIRIUS Contents IEC Power Control • Revised • 04/20/15 Motor Starter Protectors Pages Section Overview . . . . . . . . . . . . . . . . . . . . . . . . . 1/2 - 1/3 Motor Starter Protectors 3RV20 MSP, Class 10/20 . . . . . . . . . . . . . . . . . . . . 1/4 - 1/5 3RV10 MSP, Class 10/20 . . . . . . . . . . . . . . . . . . . . . . . . 1/5 Circuit Breakers 3RV17 Circuit Breaker UL 489 . . . . . . . . . . . . . . . . . . . . 1/6 3RV27, 3RV28 Circuit Breaker UL 489. . . . . . . . . . . . . . 1/6 Accessories Auxiliary Switches. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/7 Auxiliary Releases. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/7 Busbars. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/8 Mounting Accessories. . . . . . . . . . . . . . . . . . . . . . 1/9 - 1/12 Rotary Operating Mechanisms. . . . . . . . . . . . . . . . . . . 1/13 Enclosures & Front Plates. . . . . . . . . . . . . . . . . . . . . . . 1/13 3RV29 Infeed System. . . . . . . . . . . . . . . . . . . . . 1/14 - 1/17 General Data for Motor Starter Protectors Manual Motor Starter Ratings. . . . . . . . . . . . . . . . . . . . Group Installation Ratings. . . . . . . . . . . . . . . . . . . . . . . Combination Motor Controller Ratings. . . . . . . . . . . . . 3RV27 and 3RV28 Circuit Breaker Ratings. . . . . . . . . . Export Application Ratings . . . . . . . . . . . . . . . . . 1/22 Rules for Mounting . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . 1/25 Overview of MSP Functions & Applications. . . . . . . . . Application as a Combination Motor Controller . . . . . . Application in DC Switching . . . . . . . . . . . . . . . . . . . . . Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Characteristics. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Circuit Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/33 General Data for Accessories Mountable Accessories Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/35 Circuit Diagrams . . . . . . . . . . . . . . . . . . . . . . . 1/37 Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Busbar Accessories Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/40 Operating Mechanisms Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Circuit Diagrams . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/43 Enclosures & Front Plates Overview. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Spring Terminal Infeed System Design. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Technical Data. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Dimensions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . Siemens Industry, Inc. Industrial Controls Catalog 1/18 1/19 1/20 1/21 1/23 1/24 1/28 1/29 1/30 1/31 1/31 1/32 1/32 1/34 1/36 1/35 1/38 1/39 1/41 1/42 1/43 1/44 1/45 1/46 1/47 1/47 1/48 1/1 IEC Power Control • Revised • 04/20/15 Motor Starter Protectors SIRIUS 3RV motor starter protectors up to 100 A Size S00, S0 For motor protection CLASS 10 For motor protection CLASS 20 Selection and ordering data Size S00 S0 S2 S3 Rated Current up to 16 A up to 40 A up to 65 A up to 100 A Selection and ordering data Page 1/4 1/4 1/5 1/5 Ciruit Breakers 3RV17, 3RV27, 3RV28 Selection and ordering data Dimension drawings 1/2 General data for SIRIUS motor starter protectors Size S2 S3 Rated Current up to 65 A up to 100 A Page 1/5 1/5 1/6 1/34 Page 1/18 1/28 1/32 1/32 1/33 3RV MSP auxiliaries and accessories SIRIUS 3RV29 infeed system Page Technical data Overview Characteristics Circuit diagrams Dimension drawings Page Page Selection and ordering data 1/16-1/17 Selection and ordering data 1/7-1/8 Technical data Overview Dimension drawings Technical data Overview Circuit diagrams Dimension drawings 1/47 1/14-1/15 1/48 Product Category: IEC 1/27 1/35 1/37 1/38 Siemens Industry, Inc. Industrial Controls Catalog IEC Power Control Accessories 3RV busbar and accessories Accessories for motor starter protectors with Spring-Type terminals Mounting Accessories Selection and ordering data Overview Technical data Page 1/8 1/39 1/40 Rotary operating mechanisms Page Selection and ordering data Technical data 1/7 1/28 Overview Technical data Page 1/9 -1/12 1/36 1/38 Enclosures and front plates Page Page Selection and ordering data 1/13 Selection and ordering data 1/13 Technical data Overview Circuit diagrams Dimension drawings 1/28 1/42 1/43 1/43 Overview Dimension drawings 1/45 1/46 Siemens Industry, Inc. Industrial Controls Catalog Selection and ordering data Product Category: IEC 1/3 3RV Motor Starter Protectors For Motor Protection SIRIUS 3RV20 Class 10 up to 40A Description Ordering Information The 3RV20x MSP’s are UL approved as Self Protected Combination Motor Controllers which are also called Type E. In this application, all the required functions for a motor branch are provided in one device: disconnect, short circuit protection, motor control and overload protection. A type E terminal adaptor is required. The 3RV20x MSP’s are also approved for use as follows: – Manual Motor Controller: Motor starter, motor disconnect, control and overload— protection. – Group Installation: Motor starter only, motor disconnect, control and overload protection. – Tap conductor Protection in Group Installation acc. NEC: Motor starter only; motor disconnect, control and overload protection. E When the 3RV20x is used with one of the 3 above mentioned approvals, the 3RV20x can be installed downstream of one circuit breaker or fuse set. E For more detailed application information and rules how to apply, size and rate the 3RV20x in control panels in general, in group installations or in accordance to international IEC standards visit our website: www.usa.siemens.com/controlpaneldesign E E E E E E E E E E E ON/OFF rotary handle with lockout and visible trip indication. Adjustment dial for setting to motor FLA. Class 10 overload trip characteristics. Short circuit trip at 13 times the maximum setting of the FLA adjustment dial. Short circuit current rating: Ambient compensated up to 140° F (applies to side by side mounting). Phase loss sensitivity. Test trip function. Terminal versions: screw, spring, ring lug. Auxiliaries and Accessories see pages 1/7–1/17. General Information see pages 1/29–1/32. Technical Data see pages 1/18–1/28. Dimensions see page 1/33. Note: Select MSP by motor Full Load Amperes. Horsepower ratings are for reference only. Illustration FLA Adjustment Range [A] 0.11-0.16 0.14-0.2 0.18-0.25 0.22-0.32 0.28-0.4 0.35-0.5 0.45-0.63 0.55-0.8 0.7-1 0.9-1.25 1.1-1.6 1.4-2 1.8-2.5 2.2-3.2 2.8-4 3.5-5 4.5-6.3 5.5-8 7-10 9-12.5 11-16 14-20 17-22 20-25 23-28 27-32 3) 30-36 3) 34-40 Single-Phase HP Ratings Three-Phase 1) HP Ratings 115V 230V 200V 230V 460V 575V Instantaneous short circuit release [A] — — — — — — — — — — — — — 1⁄10 1⁄8 1⁄6 ¼ 1⁄3 ½ ½ 1 1½ 1½ 2 2 2 3 3 — — — — — — — — — — 1⁄10 1⁄8 1⁄6 ¼ 1⁄3 ½ ½ 1 1½ 2 2 3 3 3 5 5 5 7½ — — — — — — — — — — — — ½ ½ ¾ 1 1 2 2 3 3 5 5 5 7½ 7½ 10 10 — — — — — — — — — — — — ½ ¾ ¾ 1 1½ 2 3 3 5 5 7½ 7½ 10 10 10 10 — — — — — — — — — ½ ¾ ¾ 1 1½ 2 3 3 5 5 7½ 10 10 15 15 20 20 25 30 — — — — — — — — ½ ½ ¾ 1 1½ 2 3 3 5 5 7½ 10 — — — — — — — — 2.1 2.6 3.3 4.2 5.2 6.5 8.2 10 13 16 21 26 33 42 52 65 82 104 130 163 208 260 286 325 364 400 432 480 1) Select motor starter protector by motor full load amps. Horse power ratings for reference only. 1/4 UL shortcircuit breaking capacity @ 480V [kA] 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 50 50 12 12 2) The motor starter protectors rated up to 32 A can be used as manual motor controllers or as Type E combination motor controllers. For use as a Type E combination motor controller, a Type E terminal is required. See accessories page 1/10. Product Category: IEC Size S00 2) 4) Size S0 2) 4) Order Number Order Number — 3RV2011-0AA●● 3RV2011-0BA●● — 3RV2011-0CA●● — 3RV2011-0DA●● — 3RV2011-0EA●● — 3RV2011-0FA●● — 3RV2011-0GA●● 3RV2021-0GA●● 3RV2011-0HA●● 3RV2021-0HA●● 3RV2011-0JA●● 3RV2021-0JA●● 3RV2011-0KA●● 3RV2021-0KA●● 3RV2011-1AA●● 3RV2021-1AA●● 3RV2011-1BA●● 3RV2021-1BA●● 3RV2011-1CA●● 3RV2021-1CA●● 3RV2011-1DA●● 3RV2021-1DA●● 3RV2011-1EA●● 3RV2021-1EA●● 3RV2011-1FA●● 3RV2021-1FA●● 3RV2011-1GA●● 3RV2021-1GA●● 3RV2011-1HA●● 3RV2021-1HA●● 3RV2011-1JA●● 3RV2021-1JA●● 3RV2011-1KA●● 3RV2021-1KA●● 3RV2011-4AA●● 3RV2021-4AA●● — 3RV2021-4BA●● — 3RV2021-4CA●● — 3RV2021-4DA●● — 3RV2021-4NA●● — 3RV2021-4EA●● — 3RV2021-4PA●● — 3RV2021-4FA●● Screw terminals, no auxiliary: ●● = 10 Screw Terminals, with 1NO/1NC Aux:●● = 15 Spring terminals, no auxiliary: ●● = 20 Spring Terminals, with 1NO/1NC Aux: ●● = 25 Ring Lug Terminals, no Auxiliary: ●● = 40 3) These products are NOT certified as Type E combination motor controllers. They can only be used as manual motor controllers. 4) 3RV2 MSP’s can only be used with Innovations contactors and accessories Siemens Industry, Inc. Industrial Controls Catalog 3RV Motor Starter Protectors • Revised • 04/20/15 SIRIUS For Motor Protection 3RV10 Class 10 & 20 up to 100A Description Ordering Information The 3RV203 / 104 MSP’s are UL approved as Self Protected Combination Motor Controllers which are also called Type E. In this application, all the required functions for a motor branch are provided in one device: disconnect, short circuit protection, motor control and overload protection. A type E terminal adaptor is required for all S2 frame 3RV2031 above 45A and all S2 frame 3RV2032 as well as for all S3 frame motor starter protectors. E ON/OFF rotary handle with lockout and visible trip indication. E Adjustment dial for setting to motor FLA. EClass 10 overload trip characteristics. E Short circuit trip at 13 times the maximum setting of the FLA adjustment dial. E Short circuit current rating: E Ambient compensated up to 140° F (applies to side by side mounting). EPhase loss sensitivity. ETest trip function. E Auxiliaries and Accessories see pages 1/7–1/17. E General Information see pages 1/29–1/32. E Technical Data see pages 1/18–1/28. E Dimensions see page 1/33. The 3RV203 / 104 MSP’s are also approved for use as follows: – Manual Motor Controller: Motor starter, motor disconnect, control and overload protection. – Group Installation: Motor starter only, motor disconnect, control and overload protection. – Tap conductor Protection in Group Installation acc. NEC: Motor starter only; motor disconnect, control and overload protection. When the 3RV203 /104 is used with one of the 3 above mentioned approvals, they can be installed downstream of one circuit breaker or fuse set. For more detailed application information and rules how to apply, size and rate these MSP’s in control panels in general, in group installations or in accordance to international IEC standards visit our website: www.usa.siemens.com/controlpaneldesign Note: Select MSP by motor Full Load Amperes. Horsepower ratings are for reference only. Illustration FLA Adjustment Range [A] Single Phase 1) HP rating 3 Phase 1) HP Rating 115V 200V 240V 230V 460V 575V Inst. ShortCircuit Release [A] UL AIC (480V) [kA] 6) Trip Class 10 Trip Class 20 Order Number4) Order Number4) 3RV2031-4SB10 3RV203 Frame Size S2 9.5 - 14 1.5 3 5 5 10 15 208 65 3RV2031-4SA10 12 - 17 1.5 3 5 7.5 15 15 260 65 3RV2031-4TA10 3RV2031-4TB10 14 - 20 1.5 3 7.5 7.5 15 20 260 65 3RV2031-4BA10 3RV2031-4BB10 18 - 25 2 5 10 20 25 325 65 3RV2031-4DA10 3RV2031-4DB10 22 - 32 3 5 10 10 25 30 416 65 3RV2031-4EA10 3RV2031-4EB10 28 - 36 3 7.5 15 15 30 40 520 65 3RV2031-4PA10 3RV2031-4PB10 32 - 40 3 7.5 15 15 30 40 585 65 3RV2031-4UA10 3RV2031-4UB10 35 - 45 3 10 15 15 40 50 650 65 3RV2031-4VA10 3RV2031-4VB10 42 - 52 5 10 15 20 40 50 741 65 3RV2031-4WA10 3RV2031-4WB10 49 - 59 5 15 20 25 50 60 845 30 3RV2031-4XA10 3RV2031-4XB10 54 - 65 5 15 20 25 50 60 845 30 3RV2031-4JA10 3RV2031-4JB10 7.5 3RV104 Frame Size S3 28 - 40 3 15 15 30 40 520A 65 3RV1041-4FA10 3RV1042-4FB10 36 - 50 5 10 15 20 40 50 650A 65 3RV1041-4HA10 3RV1042-4HB10 45 - 63 5 15 20 25 50 60 819A 65 3RV1041-4JA10 3RV1042-4JB10 57 - 75 7.5 15 25 25 60 75 975A 65 3RV1041-4KA10 3RV1042-4KB10 7.5 70 - 90 10 20 30 30 75 100 3) 1170A 65 3RV1041-4LA10 3RV1042-4LB10 80 - 100 10 25 40 40 75 100 3) 1235A 65 3RV1041-4MA10 3RV1042-4MB10 1) Select motor starter protector by motor full load amps. Horse power ratings for reference only. 3) Shaded ratings apply for group installation only. These ratings do not apply as UL listed manual combination starters. 5) 3RV1 MSP’s can only be used with 3RT1 contactors and accessories. 3RV2 MSP’s can only be used with 3RT2 contactors and accessories. 2) Size S2 and S3 are listed as type E combination motor controllers. For required Type E terminals see page 1/10. 4) Pre-assembled motor starter protector and transverse 6) For 100kA SCCR rated MSP’s, change the part number 3RV2031 MSP’s with a current setting limit of 45A or less auxiliary switch with 1NO + 1NC is available. Replace the from 3RV2031 to 3RV2032. (applies to S2 frame only do not require a type E terminal and fulfill the spacing last digit of the order no. with a “5”. through 65A). requirements of UL508. Refer to pages 1/18 to 1/20 when using an MSP in a Manual Motor Starter or a Manual Self-Protected Combination Motor Controller. Siemens Industry, Inc. Industrial Controls Catalog Product Category: IEC 1/5 3RV Circuit Breakers UL 489 SIRIUS 3RV up to 70 A Selection and ordering data Rated Cur1) rent [A] Thermal overload release (non-adjustable) [A] Short Circuit breaking capacity [kA] 480 VAC 480Y/ 277VAC 600Y/ 347VAC For Motor Protection 2) For Transformer Protection 3) Instantaneous Over Current Release [A] Instantaneous Over Current Release [A] Order Number (Screw Terminals) Weight [kg] Order Number (Screw Terminals) Weight [kg] Innovations Frame Size S00 4) 0.16 0.16 — 65 10 2.1 3RV2711-0AD10 0.390 3.3 3RV2811-0AD10 0.390 0.2 0.2 — 65 10 2.6 3RV2711-0BD10 0.390 4.2 3RV2811-0BD10 0.390 0.25 0.25 — 65 10 3.3 3RV2711-0CD10 0.390 5.2 3RV2811-0CD10 0.390 0.32 0.32 — 65 10 4.2 3RV2711-0DD10 0.390 6.5 3RV2811-0DD10 0.390 0.4 0.4 — 65 10 5.2 3RV2711-0ED10 0.390 8.2 3RV2811-0ED10 0.390 0.5 0.5 — 65 10 6.5 3RV2711-0FD10 0.390 10 3RV2811-0FD10 0.390 0.63 0.63 — 65 10 8.2 3RV2711-0GD10 0.390 13 3RV2811-0GD10 0.400 0.8 0.8 — 65 10 10 3RV2711-0HD10 0.390 16 3RV2811-0HD10 0.450 1 1 — 65 10 13 3RV2711-0JD10 0.450 21 3RV2811-0JD10 0.450 1.25 1.25 — 65 10 16 3RV2711-0KD10 0.450 26 3RV2811-0KD10 0.460 1.6 1.6 — 65 10 21 3RV2711-1AD10 0.460 33 3RV2811-1AD10 0.460 2 2 — 65 10 26 3RV2711-1BD10 0.460 42 3RV2811-1BD10 0.460 2.5 2.5 — 65 10 33 3RV2711-1CD10 0.460 52 3RV2811-1CD10 0.460 3.2 3.2 — 65 10 42 3RV2711-1DD10 0.460 65 3RV2811-1DD10 0.460 4 4 — 65 10 52 3RV2711-1ED10 0.450 82 3RV2811-1ED10 0.460 5 5 — 65 10 65 3RV2711-1FD10 0.460 104 3RV2811-1FD10 0.460 6.3 6.3 — 65 10 82 3RV2711-1GD10 0.460 130 3RV2811-1GD10 0.460 8 8 — 65 10 104 3RV2711-1HD10 0.460 163 3RV2811-1HD10 0.460 10 10 — 65 10 130 3RV2711-1JD10 0.460 208 3RV2811-1JD10 0.460 12.5 12.5 — 65 10 163 3RV2711-1KD10 0.460 260 3RV2811-1KD10 0.460 15 15 — 65 — 208 3RV2711-4AD10 0.470 286 3RV2811-4AD10 0.470 Innovations Frame Size S0 4) 20 20 — 50 — 260 3RV2721-4BD10 0.514 325 3RV2821-4BD10 0.516 22 22 — 50 — 286 3RV2721-4CD10 0.516 364 3RV2821-4CD10 0.528 10 10 65 — 20 150 3RV1742-5AD10 0.460 — — — 15 15 65 — 20 225 3RV1742-5BD10 0.460 — — — 20 20 65 — 20 260 3RV1742-5CD10 0.460 — — — 25 25 65 — 20 325 3RV1742-5DD10 0.460 — — — 30 30 65 — 20 390 3RV1742-5ED10 0.460 — — — 35 35 — 65 20 455 3RV1742-5FD10 0.460 — — — 40 40 — 65 20 520 3RV1742-5GD10 0.460 — — — 45 45 — 65 20 585 3RV1742-5HD10 0.460 — — — 50 50 — 65 20 650 3RV1742-5JD10 0.460 — — — 60 60 — 65 20 780 3RV1742-5LD10 0.460 — — — 70 70 — 65 10 910 3RV1742-5QD10 0.460 — — — Classic Frame Size S3 5) 1) 100 % rated value acc. to UL 489 and IEC 60947-2 (100 % rated breaker). 2) Circuit breakers for system protection of motor and non-motor loads. Requires use of separate overload protection for motor applications. 3) Circuit breakers for system and transformer protection according to UL/CSA. Specially designed for transformers with high inrush current. 5) Transverse auxiliary switches must not be mounted. Lateral auxiliary switches can be ordered separately (see “Mountable accessories”). 4) Transverse and lateral auxiliary switches can be ordered separately (see “Mountable accessories”). Refer to page 1/21 when using as upstream protection of a Manual Motor Controller or a Manual Motor Controller Suitable for Tap Conductor Protection in Group Installations. 1/6 Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog 3RV Motor Starter Protectors • Revised • 04/20/15 SIRIUS Accessories Auxiliaries and Accessories Selection and ordering data W i d t h Version Transverse auxiliary switches 1 CO 1 NO + 1 NC 2 NO S3 Solid-state compatible, transverse auxiliary 1 CO Auxiliary switches 3RV2901-1E 3RV1901-1G 3RV2901-1G 3RV1901-1A 3RV2901-1A Fits 3RV1 Frame Size Type 3) 3RV1901-1E Classic Screw Connection Order No. Innovations 3RV1901-1D 3RV1901-1E 3RV1901-1F S00, S0, S2 S3 3RV1901-1G S00, S0, S2 3RV2901-1G S3 3RV1901-0H S00, S0, S2 3RV2901-0H 3RV1901-1A 3RV1901-1B 3RV1901-1C 3RV1901-1J S00, S0, S2 1) 1) 1), 2) 1) 3RV2901-1D 3RV2901-1E 3RV2901-1F switches for use in dusty atmosphere and in electronic circuits with low operating currents Lateral auxiliary switches (side mount) Width = 9 mm 1 NO + 1 NC 2 NO 2 NC 2 NO + 2 NC 9 9 9 18 S3 1 NO + 1 NC each 18 S3 1) 1) 1) Signaling switch Signaling switch (side mount) Individual tripped and short-circuit signaling 3RV1921-1M 1), 2) 1) 1) Classic 4) 3RV2921-1M Fits 3RV2 Frame Size Classic mm Covering caps for transverse auxiliary switch slots (pack of 10) 3RV1921-1M Screw Connection Order No. Innovations 3RV2901-1A 3RV2901-1B 3RV2901-1C 3RV2901-1J Innovations S00, S0, S2 1), 2) 3RV2921-1M Width = 18 mm Classic Auxiliary releases 5) 3RV1902-1AB4 3RV2902-1AB4 Undervoltage releases (side mount) DC 24 V Width = 18 mm AC 50 Hz 24 V 110 V — 230 V 400 V 415 V 500 V AC 60 Hz — 120 V 208 V 240 V 440 V 480 V 600 V 230 V 400 V 415 V 230 V 400 V 415 V 240 V 440 V 480 V 240 V 440 V 480 V AC 50/60 Hz 6) 100% ON 20-24 V 90-110 V 210-240 V 350-415 V 500 V AC 50/60 Hz 7) 5 sec ON 20-70 V 70-190 V 190-330 V 330-500 V 500 V Undervoltage releases with leading auxiliary contacts 2 NO (side mount) Width = 18 mm Shunt releases (side mount) Width = 18 mm 1) This product is also available with spring terminals. The order no. must be changed in the 8th position to a “2”:e.g. 3RV1901-2E or 3RV2901-2E 2) This product is also available with ring lug terminals. The order no. must be changed in the 8th position to a “4”: e.g. 3RV2901-4E Siemens Industry, Inc. Industrial Controls Catalog Innovations S3 3RV1902-1AB4 S00, S0, S2 3RV2902-1AB4 S3 3RV1902-1AB0 3RV1902-1AF0 3RV1902-1AM1 3RV1902-1AP0 3RV1902-1AV0 3RV1902-1AV1 3RV1902-1AS0 S00, S0, S2 3RV2902-1AB0 3RV2902-1AF0 3RV2902-1AM1 3RV2902-1AP0 3RV2902-1AV0 3RV2902-1AV1 3RV2902-1AS0 1), 2) 1), 2) S00, S0, S2 S3 S3 3) Each motor starter protector can be fitted with one transverse and one lateral auxiliary switch. The lateral auxiliary switch 2 NO + 2 NC is used without transverse auxiliary switch. 4) One signaling switch can be mounted at the left of the motor starter protector. This accessory cannot be used on the 3RV27 and 3RV28 circuit breakers. Product Category: IEC 3RV1922-1CP0 3RV1922-1CV0 3RV1922-1CV1 S00, S0, S2 3RV1902-1DB0 3RV1902-1DF0 3RV1902-1DP0 3RV1902-1DV0 3RV1902-1DS0 S00, S0, S2 1) 1) 1), 2) 1) 1) 1), 2) 1), 2) 1), 2) 1) 3RV2922-1CP0 3RV2922-1CV0 3RV2922-1CV1 3RV2922-1CP0 3RV2922-1CV0 3RV2922-1CV1 3RV2902-1DB0 3RV2902-1DF0 3RV2902-1DP0 3RV2902-1DV0 3RV2902-1DS0 5) One auxiliary release can be mounted at the right of each MSP. motor starter protector. 6) The response voltage at the lower limit of the voltage range at 0.85 (Tu=60°C) is valid for 100% (infinite) 7) The response voltage at the lower limit of the voltage range at 0.9 (Tu=60°C) applies for a duty cycle of 5 seconds at AC 50/60 Hz and DC. 1/7 3RV Motor Starter Protectors • Revised • 04/20/15 Accessories SIRIUS Accessories for Busbar Selection and ordering data Modular spacing Number of motor starter protectors that can be connected Without lateral accessories Incl. lateral auxiliary switch With auxiliary trip unit mm Rated current In at 690 V For motor starter protectors Size Order No. Order quantity Weight approx. kg A Three-phase busbar systems for Classic and Innovations 3RV19 15-1AB 3RV19 15-1BB 3RV19 15-1CB 3RV19 15-1DB 1) For feeding several motor starter protectors with screw terminals, mounted side-by-side on standard mounting rails, insulated, with touch protection. 45 2 3 4 5 -- -- 63 S00, S01)2) S00, S01)2) S00, S01)2) S00, S01)2) 3RV19 15-1AB 3RV19 15-1BB 3RV19 15-1CB 3RV19 15-1DB 1 unit 1 unit 1 unit 1 unit 0.044 0.071 0.099 0.124 55 -- 2 3 4 5 -- 63 S00, S01)2) S00, S01)2) S00, S01)2) S00, S01)2) 3RV19 15-2AB 3RV19 15-2BB 3RV19 15-2CB 3RV19 15-2DB 1 unit 1 unit 1 unit 1 unit 0.048 0.079 0.111 0.140 63 -- -- 2 4 63 S00, S01)2) S00, S01)2) 3RV19 15-3AB 3RV19 15-3CB 1 unit 1 unit 0.052 0.120 55 2 3 4 -- -- 108 S23) S23) S23) 3RV19 35-1A 3RV19 35-1B 3RV19 35-1C 1 unit 1 unit 1 unit 0.150 0.214 0.295 75 -- 2 3 4 2 3 4 108 S2 S2 S2 3RV19 35-3A 3RV19 35-3B 3RV19 35-3C 1 unit 1 unit 1 unit 0.161 0.262 0.369 Not suitable for 3RV11 motor starter protectors with overload relay function. The 3RV1915-5DB connecting piece is available for connecting motor starter protectors from size S0 to size S00. Version Modular spacing For motor starter protectors Size 2) Not suitable for 3RV UL 489 circuit breakers. 3) Auxiliary trip units and lateral auxiliary switches cannot be used in combination. Order No. Order quantity kg mm Connecting pieces for three-phase busbars 3RV19 15-5DB For Classic and Innovations For connecting three-phase 45 busbars for motor starter protectors of size S0 (left) to size S00 (right) Conductor cross-section, AWG cables, solid or stranded Weight approx. S00, S0 For 3RV1 MSP For 3RV2 MSP Tightening torque AWG AWG Nm For motor starter protector size 1 unit 3RV19 15-5DB 3RV1 Classic 1) 3RV2 Innovations 2) Order No. Order No. 0.042 Three-phase feeder terminals 3RV29 25-5AB 3RV2915-5B Connection from top — 10…4 3…4 S00 — 3RV2925-5AB — 10…4 3…4 S0 — 3RV2925-5AB Input: 4, S00, S0 — 3RV2915-5B 3RV1935-5A 3RV2935-5A Classic Innovations Connection from below — 10…4 3) Output: 2 ... 2.5 3RV2935-5A Connection from top 14...0 -- 4-6 S2 Three-phase feeder terminals for constructing “Type E Starters” 3RV2935-5E Connection from top — 10…4 3-4 S00 — 3RV2925-5EB — 10…4 3-4 S0 — 3RV2925-5EB 8...0 10...2/0 4.5-6 S2 — 3RV2935-5E 1) Do not mix 3RV1 Classic Accessories with 3RV2 Innovations MSP’s 1/8 2) Do not mix 3RV2 Innovations Accessories with 3RV1 Classic MSP’s Product Category: IEC 3) This terminal is connected in place of a switch, please take the space requirement into account. Siemens Industry, Inc. Industrial Controls Catalog 3RV Motor Starter Protectors • Revised • Motor Starter Protectors/Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 80 A SIRIUS 04/20/15 Accessories Accessories Mounting accessories Mounting accessories Overview Link modules Accessories for "Self-Protected Combination Motor Controllers (Type E)" according to UL 508/UL 60947-4-1 The 3RV20 motor starter protectors with screw terminals are approved according to UL 508/UL 60947-4-1 as "Self-Protected Combination Motor Controllers (Type E)". This requires increased clearance and creepage distances (1 inch and 2 inches respectively) at the input side of the device, which are achieved by mounting a terminal block or a phase barrier. Combination 3RV2 devices motor starter protectors/ circuit breakers Size Size c 3RT2 contac- S00 tors with AC or DC coil S0 S00 SIRIUS 3RV2928-1H terminal block 7 IC0 08 04 0 1_ SIRIUS 3RV2938-1K phase barrier Motor starter protectors/ circuit breakers Size 3RV2928-1H terminal block or 3RV2928-1K phase barrier 3RV2031-4B1., 3RV2031-4D.1., 3RV2031-4E1., 3RV2031-4P.1., 3RV2031-4S.1., 3RV2031-4T.1., 3RV2031-4U.1., 3RV2031-4V.1. S2 -- 3RV2031-4J.1., 3RV2031-4K.1., 3RV2031-4R.1., 3RV2031-4W.1., 3RV2031-4X.1., 3RV2032 S2 -3RA29311AA00 -- 3RT2 contactors with AC coil S0 S0 3RA29211AA00 3RA29212AA00 S00 S0 3RT2 contactors with DC coil S0 S0 S00 S0 3RW30 soft starters S00 S00 S0 S00 S0 S0 S00 S0 S22) S22) 3RA29311AA00 -- S00/S0 S00 3RA29211BA00 -- -3RA29211BA00 3RA29212AA00 -- 3RA29211BA00 3RA29112GA00 -- 3RA29211BA00 3RA29212GA00 -- Hybrid link modules for connecting contactors with spring-type terminals to 3RV2 motor starter protectors/circuit breakers with screw terminals3) 3RT2 contac- S00 tors with AC or DC coil S0 3RV2938-1K phase barrier The 3RV29 infeed system also enables the assembly of “Type E Starters”, see page 1/14 onwards. Note: According to CSA, these terminal blocks and the phase barriers can be omitted when the device is used as a "Self-Protected Combination Motor Controller (Type E)". 3RA29112FA00 -- S0 3RA29212FA00 -- 1) The link modules cannot be used for the 3RV2.21-4PA1., 3RV2.21-4FA1., 3RV2.31-4K.1., 3RV2.31-4R.1., 3RV2.32-4K.1., 3RV2.32-4R.1., 3RV27 and 3RV28 motor starter protectors/circuit breakers. 2) To assemble the feeder between a motor starter protector and a soft starter in size S2, the 3RA2932-1AC00 standard mounting rail adapter must be used. 3) The motor starter protector to contactor hybrid link modules cannot be used for the 3RV2.21-4PA1., 3RV2.21-4FA1., 3RV27 and 3RV28 motor starter protectors/circuit breakers. They are only suitable for constructing direct-on-line starters. Note: • Link modules can be used in - Sizes S00 and S0: up to max. 32 A - Size S2: up to max. 65 A • Hybrid link modules can be used in - Sizes S00 and S0: up to max. 32 A Product Category: IEC Siemens IC 10 · 2015 S00 -- Version not possible Special threephase infeed terminals are required for constructing “Type E Starters” with an insulated threephase busbar system (see page 1/8). 7/38 S00 3RA29112AA00 S2 3RF34 solidstate contactors -- No accessories needed Siemens Industry, Inc. Industrial Controls Catalog 3RA19211DA00 S2 3RW30/ 3RW40 soft starters Essential accessories for "Self-Protected Combination Motor Controllers (Type E)" according to UL 508/UL 60947-4-1 3RV201., 3RV202. S00/S0 3RT2 contactors; Link modules 3RW30, 3RW40 Screw Spring-type soft starters; terminals terminals 3RF34 solid-state contactors Link modules for connecting switching devices to 3RV2 motor starter protectors/circuit breakers1) 379 _01 B0 NS Feeders can be easily assembled from single devices with the help of the link modules. The following table shows the different combination options for devices with screw or spring-type terminals. 1/9 3RV Motor Starter Protectors • Revised • 04/20/15 Accessories SIRIUS Mounting accessories Selection and ordering data For motor starter protector size Version Classic 3RV1/3RT1 Order No. Innovations 3RV2/3RT2 Order No. Order Quantity Terminal blocks and phase barriers for “Self-Protected Combination Motor Controllers (Type E)” according to UL 508 / UL 60947-4-1 3RV29 28-1H Note: UL 508 / UL 60947-4-1 demands 1-inch clearance and 2-inch creepage distance at line side for “Combination Motor Controller Type E”. The following terminal blocks or phase barriers must be used on 3RV motor starter protectors. The terminal blocks or phase barriers cannot be used in combination with the 3RV19 .5 three-phase busbars. For construction with three-phase busbars, see “Accessories for busbar” Terminal blocks type E For extended clearance and creepage distances (1 and 2 inch) S00, S0 — 3RV29 28-1H 1 unit S0 — — 1 unit — 3RV29 35-5E 1 unit — 1 unit S2 3RT19 46-4GA07 S3 3RV29 28-1K 3RT1946-4GA07 Phase barriers For extended clearance and creepage distances (1 and 2 inch) S00, S0 — 3RV29 28-1K 1 unit S2 — 3RV29 38-1K 1 unit Actuating voltage of contactor 3RV motor starter protector Size 3RT contactor Classic 3RV1/3RT1 Order No. Innovations 3RV2/3RT2 Order No. Order Quantity Link modules for motor starter protector to contactor 1) For mechanical and electrical connection between motor starter protector and contactor with screw terminals. Screw Terminals Single-unit packaging 3RA29 21-1AA00 AC/DC S00 S00/S0 — 3RA19 21-1DA00 1 unit AC S0 S00/S0 — 3RA29 21-1AA00 1 unit AC S2 S2 3RA19 31-1AA00 AC S3 S3 3RA19 41-1AA00 3RA29 31-1AA00 — 1 unit 1 unit DC S0 S00/S0 — 3RA29 21-1BA00 1 unit DC S2 S2 3RA19 31-1BA00 3RA29 31-1AA00 1 unit DC S3 S3 3RA19 41-1BA00 — 1 unit Multi-unit packaging AC/DC S00 S00/S0 — 3RA19 21-1D 10 units AC S0 S00/S0 — 3RA29 21-1A 10 units DC S0 S00/S0 — 3RA29 21-1B 10 units AC/DC S2 S2 — 3RA29 31-1A 5 units For mechanical and electrical connection between motor starter protector and contactor with spring-type terminals. Spring-type Terminals Single-unit packaging AC/DC AC 3RA29 11-2AA00 2) DC S00 S00 — 3RA29 11-2AA00 S0 S0 — 3RA29 21-2AA00 1 unit S0 S0 — 3RA29 21-2AA00 1 unit S00 S00 — 3RA29 11-2A S0 S0 — 3RA29 21-2A 10 units S0 S0 — 3RA29 21-2A 10 units 1 unit Multi-unit packaging AC/DC AC 2) DC 10 units Spacers For compensating height on AC contactors Single-unit packaging S0 S0 — 3RA29 11-1CA00 Multi-unit packaging S0 — 3RA29 11-1C S0 1) The link modules for motor starter protector to contactor cannot be used for the 3RV2. 21-4PA1., 3RV2. 21-4FA1., 3RV27 and 3RV28 motor starter protectors 2) A spacer for height compensation on AC contactors size S0 is optionally available 1/10 1 unit 5 units Note Size S0 link modules can be used up to max. 32 A. Size S2 link modules can be used up to 65A max. Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog LV1N_05_04.fm Page 30 Friday, September 27, 2013 2:28 PM 3RV Motor Starter Protectors • Revised • SIRIUS 04/20/15 SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up toAccessories 40 A Accessories Mounting accessories Mounting accessories Selection and ordering data Size 3RW30, 3RW40 soft starters; 3RF34 solid-state contactors Order No. Link modules for motor starter protector to soft starter1) 3) and motor starter protector to solid-state contactor Connection between motor starter protector and soft starter / solid-state contactor with screw terminals Single-unit packaging S00 S0 S2 3) S00 S0 S2 3) 5 1) 0.068 0.068 0.104 S00/S0 S00/S0 S2 3RA29 21-1B 3RA29 21-1B 3RA29 31-1A 1 10 units 1 10 units 1 5 units 0.068 0.068 0.104 Spring-type terminals S00 S0 3RA29 11-2GA00 3RA29 21-2GA00 1 1 1 unit 1 unit 0.038 0.072 S00 S0 3RA29 11-2G 3RA29 21-2G 1 10 units 1 10 units 0.380 0.720 Note: S0 link modules can be used up to max. 32 A. S2 link modules can be used up to max. 65 A. The link modules for motor starter protector to soft starter and for motor starter protector to solid-state contactor cannot be used for the 3RV2. 21-4PA1., 3RV2. 21-4FA1., 3RV27 and 3RV28 motor starter protectors. Actuating voltage of contactor Screw terminals 1 unit 1 unit 1 unit Multi-unit packaging 3RA29 21-2GA00 kg 1 1 1 Single-unit packaging S00 S0 Weight approx. 3RA29 21-1BA00 3RA29 21-1BA00 3RA29 31-1AA00 Connection between motor starter protector and soft starter with spring-type terminals S00 S0 PS* S00/S0 S00/S0 S2 Multi-unit packaging 3RA29 21-1BA00 PU (UNIT, SET, M) 3RV2 motor starter protectors Size Order No. PU (UNIT, SET, M) 3RT2 3RV2 contactors motor starter protectors PS* Weight approx. kg Hybrid link modules for motor starter protector to contactor1) For mechanical and electrical connection between motor starter protector with screw terminals and contactor with spring-type terminals Single-unit packaging S00 S0 S00 S0 3RA29 11-2FA00 3RA29 21-2FA00 1 1 1 unit 1 unit 0.029 0.056 AC/DC AC2)/DC S00 S0 S00 S0 3RA29 11-2F 3RA29 21-2F 1 10 units 1 10 units 0.290 0.560 Single-unit packaging Multi-unit packaging S0 S0 S0 S0 3RA29 11-1CA00 3RA29 11-1C 1 1 0.001 0.001 AC/DC AC2)/DC 3RA29 11-2FA00 Multi-unit packaging Spacers2) for compensating the height on AC contactors 1 unit 5 units 3RA29 21-2FA00 1) The hybrid link modules for motor starter protector to contactor cannot be used for the 3RV2. 21-4PA1., 3RV2. 21-4FA1., 3RV27 and 3RV28 motor starter protectors or reversing starters. 2) A spacer for height compensation on AC contactors size S0 is optionally available. See 3RA2911-1CA00 3) To assemble the starter between a motor starter protector and a soft starter in size S2, the 3RA2932-1AC00 standard mounting rail adapter must be used. Siemens Industry, Inc. Industrial Controls Catalog 5/30 Note: Hybrid link modules can be used up to max. 32 A. Product Category: IEC SIRIUS Innovations Supplement 2012 1/11 * You can order this quantity or a multiple thereof. Illustrations are approximate 3RV Motor Starter Protectors • Revised • 10/25/15 Accessories SIRIUS Mounting accessories Selection and ordering data Type Design Order Quantity Weight approx. (kg) 3RV29 28-1A 1 unit 0.132 3RV29 38-1A 1 unit 0.368 S3 3RT19 46-4F 1 unit 0.10 S2 3RT29 36-4EA2 1 unit 0.014 S3 3RT19 46-4EA2 1 unit 0.019 3RT19 46-4EA1 1 unit 0.03 For SIRIUS MSP size Order No. S00, S0 1) Isolator module 1) 3RV2938-1A without padlock 3RV29 28-1A without padlock Visible isolating distance for isolating individual motor starter protectors from the network, lockable in isolating position. S2 Auxiliary terminal, 3 pole For connection of auxiliary and control cables to the main conductor connections 3RT19 46-4F Covers 3RV1 (size S3) with 3RT19 46-4EA1 3RV29 28-4AA00 3RV29 08-4AA10 3RV29 08-0P Terminal cover Additional touch guard for box terminals to be fitted at the box terminals (2 units can be mounted per MSP) Terminal cover for cable lug and bar connection Terminal cover for devices with ring lug terminal connection Scale cover For maintaining the required voltage clearance and as protection S3 against the equipment being touched if distant box terminals are used (2 units can be mounted per MSP) S00, S0 2) 3RV29 28-4AA00 1 unit 0.01 • For transverse auxiliary switches S00, S0 2) 3RV29 08-4AA10 1 unit 0.01 For covering the current setting scale. Packing unit: Bag with 10 scale covers. S00, S0, S2 • Main current level 3) 3RV29 08-0P 10 units S3 3RV19 08-0P 10 units S00 3RB19 00-0B 10 units S00, S0, S2 3RA29 08-1A 1 unit Fixing Material 3RB1900-0B Push-in lugs For screwing the motor starter protector onto mounting plates. Two units are required for each motor starter protector. 0.10 Tools for opening spring-type terminals by hand 3RA29 08-1A Screwdriver For all SIRIUS devices with spring terminals Length approx. 200 mm, 3.0 mm x 0.5 mm, titanium gray/black partially insulated 1) The isolator module for size S2 can be used only with 3RV2 motor starter protectors/circuit breakers up to max. 65 A. Similarly, it cannot be used with the transverse auxiliary switch or three-phase busbars. 1/12 0.045 2) Compatible with 3RV20 motor starter protectors. 3) Compatible with 3RV20, 3RV21, and 3RV24 motor starter protectors. Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog SIRIUS 3RV Motor Starter Protectors • Revised • 04/20/15 Accessories Rotary operating mechanisms Selection and ordering data Type For SIRIUS MSP size Details Order No. Approx. Wt. (kg) Door-coupling rotary operating mechanisms for Classic and Innovations 3RV29 26-0B The door-coupling rotary operating mechanisms consist of a knob, a coupling driver and a 130/330 mm long extension shaft (6 mm x 6 mm). The door-coupling rotary operating mechanisms are designed to degree of protection IP65. The door locking device prevents accidental opening of the control cabinet door in the ON postion of the motor starter protector. The OFF position can be locked with up to 3 padlocks. Door-coupling rotary operating mechanisms (black) Extension shaft 130 mm S00, S0 3RV29 26-0B S2, S3 3RV29 26-0B 0.1 Extension shaft 330 mm S00, S0 3RV29 26-0K 0.324 EMERGENCY STOP door-coupling rotary operating mechanisms (red/yellow) S2, S3 3RV29 26-0K 0.3 Extension shaft 130 mm S00, S0 3RV29 26-0C 0.110 S2, S3 3RV29 26-0C 0.1 S00, S0 3RV29 26-0L 0.316 S2, S3 3RV29 26-0L 0.3 Extension shaft 330 mm 0.111 Door-coupling rotary operating mechanisms for arduous conditions 3RV29 26-2C The door-coupling rotary operating mechanisms consist of a knob, a coupling driver, an extension shaft of 300 mm length (8 mm x 8 mm), a spacer and two metal brackets, into which the MSP is is inserted. The door-coupling rotary operating mechanisms are designed for degree of protection IP 65. The door locking device reliably prevents accidental opening of the control cabinet door in the ON position of the MSP. The OFF postion can be locked with up to 3 padlocks. Laterally mountable auxiliary releases and two-pole auxiliary switches can be used. The door-coupling rotary operating mechanisms thus meet the requirements for isolating functions according to IEC 60 947-2. Door-coupling rotary operating mechanisms (gray) S00, S0 3RV29 26-2B 1.2 S2 3RV29 36-2B 1.6 S3 3RV29 46-2B 1.7 EMERGNCY STOP door-coupling rotary operating mechanisms (red/yellow) S00, S0 3RV29 26-2C 1.2 S2 3RV29 36-2C 1.5 S3 3RV29 46-2C 1.7 Enclosures and front plates Type For SIRIUS MSP size Details Order No. Approx. Wt. (kg) Front Plates 3RV19 23-4B + 3RV19 23-4G Molded-plastic front plate For actuation of 3RV MSP’s in any with rotary operating mechanism, enclosure, degree of protection IP 55 lockable. For actuation of 3RV motor (front plate) starter protectors in any enclosure S00, S0 S2, S3 3RV19 23-4B 0.08 Molded-plastic front plate with EMERGENCY STOP door-coupling rotary operating mechanisms (red/yellow) EMERGENCY-STOP operation of 3RV MSP’s in any enclosure, degree of protection IP 55 S00, S0 S2, S3 3RV19 23-4E 0.08 Holders for front plates Holder is mounted on front plate, MSP size S00 S00, S0 or S0 with or without accessories is snapped in 3RV19 23-4G 0.19 S00, S0 3RV19 23-1CA00 0.26 S00, S0 3RV19 23-1DA00 0.30 S00, S0 3RV19 23-1DA01 1.02 S00, S0 3RV19 23-1GA01 1.01 Enclosures for wall mounting 2) 3RV19 23-1CA00 Molded-plastic enclosure for wall mounting with rotary operating mechanism, lockable, with metric cable gland Degree of protection IP 55, with N and PE terminals, lockable in 0 position overall width: 54 mm (for switch + lateral auxiliary switch) 72 mm (for switch + lateral auxiliary switch + auxiliary release) 3RV19 23-1DA01 1) Cast aluminum surface-mount enclosure with rotary operating mechanism, lockable, with metric cable gland Degree of protection IP 65, with PE terminals, lockable in 0 position overall width: Cast aluminum surface-mount enclosure with EMERGENCY-OFF rotary operating mechanism, red/yellow, lockable, with metric cable gland Degree of protection IP 65, with PE terminals, lockable in 0 position overall width: 72 mm (for MSP + lateral auxiliary switch + auxiliary release) 72 mm (for MSP + lateral auxiliary switch + auxiliary release) 1) If required, an additional N terminal can be mounted (e.g. 8WA10 11-1BG11). Siemens Industry, Inc. Industrial Controls Catalog 1) 2) For S2 versions, see 3RV1933-1DA00 (black) or 3RV1933-1GA00 (red/yellow) Product Category: IEC 1/13 3RV Motor Starter • Revised SIRIUS 3RV2 Motor Protectors Starter Protectors/Circuit Breakers up• to 40 A Accessories 04/20/15 3RV29 infeed system SIRIUS Accessories 3RV29 infeed system Overview The 3RV29 infeed system is a convenient means of energy supply and distribution for a group of several motor starter protectors or complete motor starters with a screw or springtype connection in sizes S00 and S0 (exception: this system cannot be used for the 3RV21, 3RV27 and 3RV28 motor starter protectors/circuit breakers). The electrical connection between the three-phase busbars and the motor starter protectors is implemented through plug-in connectors. The complete system can be mounted on a TH 35 standard mounting rail to EN 60715 and can be expanded as required up to a maximum current carrying capacity of 63 A. The system is mounted extremely quickly and easily thanks to the simple plug-in technique. Thanks to the lateral infeed, the system also saves space in the control cabinet. The additional overall height required for the infeed unit is only 30 mm. The alternative infeed possibilities on each side offer a high degree of flexibility for configuring the control cabinet: Infeed on lefthand or right-hand side as well as infeed on one side and outfeed on the other side to supply further loads are all possible. A terminal block with spring-type connections in combination with a standard mounting rail enables the integration of not only SIRIUS motor starter protectors but also single-phase, 2-phase and 3-phase components such as 5SY miniature circuit breakers or SIRIUS relay components. The 3RV29 infeed system is approved in accordance with IEC to 500V. It is also UL approved and authorized for “SelfProtected Combination Motor Controller” (Type E starter) as well as for Type F starter (Type E starter + contactor). The system is based on a basic module complete with a lateral incoming unit (three-phase busbar with infeed). This infeed with spring-type terminals is mounted on the right or left depending on the version and can be supplied with a maximum conductor cross-section of 4 AWG (with end sleeve). A basic module has two sockets onto each of which a motor starter protector can be snapped. Expansion modules are available for extending the system (three-phase busbars for system expansion). The individual modules are connected through an expansion plug. 5 5 3b 3a 5 1 2 4 7 3-phase busbar with infeed 3-phase busbar for system expansion 3a Expansion plug 3b Extra-wide expansion plug 1 4 2 5 6 7 End cover Plug-in connector Contactor base Terminal block NSB0_02078 6 3RV29 infeed system 1/14 Product Category: IEC SIRIUS Innovations Supplement 2012 Siemens Industry, Inc. Industrial Controls Catalog 5/23 3RV Motor Breakers Starter Protectors SIRIUS 3RV2 Motor Starter Protectors/Circuit up toAccessories 40 A SIRIUS Accessories 3RV29 infeed system 3RV29 infeed system $ Three-phase busbars with infeed * Contactor base A three-phase busbar with infeed unit is required for connecting the energy supply. This module comprises one infeed module and 2 sockets which each accept one motor starter protector. A choice of two versions with infeed on the left or right is available. The infeed is connected using spring-type terminals. The spring-type terminals permit conductor cross-sections of up to 25 mm2 with end sleeves. An end cover is supplied with each module. Motor starters can be assembled in the system using the contactor base. The contactor bases are suitable for contactors sizes S00 and S0 with spring-type and screw terminals and are simply snapped onto the three-phase busbars. Direct-on-line starters and reversing starters are possible. One contactor base is required for direct-on-line starters and two are required for reversing starters. % Three-phase busbars for system expansion The three-phase busbars for system expansion allow the system to be expanded. There is a choice of modules with 2 or 3 sockets. The system can be expanded as required up to a maximum current carrying capacity of 63 A. An expansion plug is supplied with each module. &a Expansion plug The expansion plug is used for electrical connection of adjacent three-phase busbars. The current carrying capacity of this plug equals 63 A. One expansion plug is supplied with each threephase busbar for system expansion. Additional expansion plugs are therefore only required as spare parts. 5 &b Extra-wide expansion plug The wide expansion plug makes the electrical connection between two three-phase busbars, thus performing the same function as the 3RV29 17-5BA00 expansion plug; the electrical characteristics (e.g. a current carrying capacity of 63 A) are identical. The 3RV29 17-5E expansion plug is 10 mm wider than the 3RV29 17-5BA00 expansion plug, hence in the plugged state there is a distance of 10 mm between the connected threephase busbars. This distance can be used to lay the auxiliary current and control current wiring ("wiring duct"). The motor starter protector and contactor can be wired from underneath, which means that the complete cable duct above the system can be omitted. ( End cover The end cover is used to cover the three-phase busbar at the open end of the system. This cover is therefore only required once for each system. An end cover is supplied with each threephase busbar system with infeed. Further end covers are therefore only required as spare parts. To assemble motor starters for reversing starters, the contactor bases can be arranged alongside each other (90 mm overall width). In this case the mechanical interlocking of the contactors is possible. The contactor bases are also suitable for soft starters size S00 and S0 with screw connection. The infeed system is designed for mounting on a 35 mm standard mounting rail with 7.5 mm overall depth. This standard mounting rail gives the contactor base a stable mounting surface to sit on. If standard mounting rails with a depth of 15 mm are used, the spacer connected to the bottom of the contactor base must be knocked out and plugged into the mating piece that is also on the underside. Then the contactor base also has a stable mounting surface. When standard mounting rails with a depth of 7.5 mm are used, the spacer has no function and can be removed. The link modules are used for direct start motor starters, in which case the use of a contactor base is not absolutely necessary. Motor starter protector and contactor assemblies can then be directly snapped onto the sockets of the three-phase busbars. For starters of size S00 and S0, the corresponding 3RA19 21-1...., 3RA29 11-2...., 3RA29 21-1.... or 3RA29 21-2.... link modules should generally be used. + Terminal block The 3RV29 17-5D terminal block enables the integration of not only SIRIUS motor starter protectors but also single-phase, 2-phase and 3-phase components. Using the terminal block the 3 phases can be fed out of the system; which means that singlephase loads can also be integrated in the system. The terminal block is plugged into the slot of the expansion plug and thus enables outfeeding from the middle or end of the infeed system. The terminal block can be rotated through 180° and be locked to the support modules of the infeed system. The 3RV19 17-7B 45 mm standard mounting rail for screwing onto the support plate is available in addition in order to be able to plug the single-phase, 2-phase and 3-phase components onto the infeed system. ) Plug-in connector The plug-in connector is used for the electrical connection between the three-phase busbar and the 3RV2 motor starter protector. These plug-in connectors are available in versions for screw or spring-type terminals. Siemens Industry, Inc. Industrial Controls Catalog 5/24 Product Category: IEC SIRIUS Innovations Supplement 2012 1/15 3RV Motor Starter • Revised SIRIUS 3RV2 Motor Protectors Starter Protectors/Circuit Breakers up• to 40 A Accessories 10/25/15 3RV29 infeed system SIRIUS Accessories 3RV29 infeed system Selection and ordering data Type Three-phase busbars with infeed 3-phase busbars with infeed incl. end cover 3RV29 17-6A Version For 3RV20, 3RV23, 3RV24 motor starter protectors Order No. Standard Pack Quantity Size Weight approx. kg For 2 motor starter protectors with screw connection or spring-type terminals • With infeed on the S00, S0 left 3RV29 17-1A 1 unit 0.369 • With infeed on the S00, S0 right 3RV29 17-1E 1 unit 0.369 • For 2 motor starter S00, S0 protectors 3RV29 17-4A 1 unit 0.229 • For 3 motor starter S00, S0 protectors 3RV29 17-4B 1 unit 0.328 • For spring-type terminals Spring-type terminals 1 unit 1 unit 0.046 0.059 10 units 10 units 0.046 0.059 1 unit 1 unit 0.029 0.040 3RV29 17-5C 3RV19 27-5A 10 units 10 units 0.029 0.036 Order No. Standard Pack Quantity 3RV29 17-1A Three-phase busbars for system expansion For motor starter protectors with screw connection or spring-type terminals 5 Three-phase busbars incl. 3RV29 175BA00 expansion plug 3RV29 17-4A Plug-in connectors Plug-in connectors to make contact with the motor starter protectors - Single-unit packaging S001) S02) - Multi-unit packaging S001) S02) 3RV29 17-5AA00 3RV29 27-5AA00 3RV29 17-5A 3RV29 27-5A 3RV29 17-5AA00 Screw terminals • For screw terminals - Single-unit packaging S001) S02) - Multi-unit packaging S001) 2) S0 3RV29 17-5CA00 3RV19 27-5AA00 3RV29 17-5CA00 Type Contactor bases Version For contactors Size Contactor bases for mounting direct-on-line or reversing starters Single-unit packaging Weight approx. kg S00 3RV29 17-7AA00 1 unit 0.042 S00, S0 3RV29 27-7AA00 1 unit 0.050 3RV29 27-7AA00 1) I > 14 A, note derating; see the system manual "SIRIUS Innovations", Chapter "Motor Starter Protectors". 2) I > 16 A, note derating; see the system manual "SIRIUS Innovations", Chapter "Motor Starter Protectors". 1/16 * You can order this quantity or a multiple thereof. Illustrations are approximate Product Category: IEC SIRIUS Innovations Supplement 2012 Siemens Industry, Inc. Industrial Controls Catalog 5/25 3RV Motor Breakers Starter Protectors SIRIUS 3RV2 Motor Starter Protectors/Circuit up to 40 A SIRIUS Accessories Accessories 3RV29 infeed system 3RV29 infeed system Type Terminal blocks Version Order No. Standard Pack Quantity Weight approx. kg Single-unit packaging 3RV29 17-5D 1 unit 0.049 Single-unit packaging 3RV19 17-7B 1 unit 0.261 Extra-wide expansion plugs as accessory Single-unit packaging 3RV29 17-5E 1 unit 0.037 Expansion plugs1) as spare part Single-unit packaging 3RV29 17-5BA00 1 unit 0.026 End covers2) as spare part Multi-unit packaging 3RV29 17-6A 10 units 0.005 Terminal blocks For integration of single-phase, two-phase and three-phase components 3RV29 17-5D 45 mm standard mounting rails 45 mm standard mounting rails for mounting onto bus bar adapters 3RV19 17-7B Extra-wide expansion plugs 5 3RV29 17-5E Expansion plugs 3RV29 17-5BA00 End covers 3RV29 17-6A 1) The expansion plug is included in the scope of supply of the 3RV29 17-4 three-phase busbars for system expansion. 2) The end cover is included in the scope of supply of the 3RV29 17-1 threephase busbars with infeed system. Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog 5/26 SIRIUS Innovations Supplement 2012 1/17 * You can order this quantity or a multiple thereof. Illustrations are approximate 3RV Motor Starter Protectors • Revised • 10/25/15 General Data 3RV up to 100 A (Domestic applications) SIRIUS Permissible rated data of devices approved for North America (UL/CSA) Permissible rated data of devices approved for North America (UL/CSA) Motor starter protectors of the 3RV2 series are approved for These motor starter protectors can be used as "Manual Motor Motor starter protectors of the 3RV2 series are approved for These motor starter protectors can be used as "Manual Motor UL/CSA, and according to UL508/UL 60947-4-1 and CSA C22.2 Controllers" for "Group Installations", as "Manual Motor ControlUL/CSA, and according to UL508/UL 60947-4-1 and CSA C22.2 Controllers" for "Group Installations", as "Manual Motor ControlSuitable for Tap Conductor Protection in Group Installations" No. 14/CSA C22.2 No. 60947-4-1 they can be used on their own lers Suitable for Tap Conductor Protection in Group Installations" No. 14/CSA C22.2 No. 60947-4-1 they can be used on their own lers and as "Self-Protected Combination Motor Controllers" (Type E). or as load feeders in combination with a contactor. and as "Self-Protected Combination Motor Controllers" (Type E). or as load feeders in combination with a contactor. 3RV motor starter protectors as "Manual Motor Controllers" 3RV motor starter protectors as "Manual Motor Controllers" If used as a "Manual Motor Controller", the motor starter protector If used as a "Manual Motor Controller", the motor starter protector is always operated in combination with an upstream short-circuit is always operated in combination with an upstream short-circuit protection device. Approved fuses or a circuit breaker accordprotection device. Approved fuses or a circuit breaker according to UL 489/CSA C22.2 No. 5 can be used. These devices ing to UL 489/CSA C22.2 No. 5 can be used. These devices must be dimensioned according to the National Electrical Code must be dimensioned according to the National Electrical Code (UL) or Canadian Electrical Code (CSA). (UL) or Canadian Electrical Code (CSA). Motor starter Motor starter protectors protectors Type Type Size S00 Size S00 V V 1) hp rating1) for FLA2) hp rating for FLA2) max. max. Rated current Rated current I Inn 240 V AC 240 V AC UL/CSA UL/CSA 3) Ibc3) Ibc 480 V AC 480 V AC UL/CSA UL/CSA 3) Ibc3) Ibc 600 V AC 600 V AC UL/CSA UL/CSA 3) Ibc3) Ibc 1-phase 1-phase 3-phase 3-phase A A kA kA kA kA kA kA 2 2 3 3 5 5 10 10 10 10 0.16 ... 2 0.16 ... 2 2.5 2.5 3.2 3.2 4 4 5 5 6.3 6.3 8 8 10 10 12.5 12.5 16 16 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 — — 0.16 ... 12.5 0.16 16 ...... 2512.5 16 28,...3225 28, 36, 32 40 36, 40 65 65 65 65 65 65 65 65 65 65 65 65 50 50 12 12 30 30 4) --/(30)4) --/(30) ----- 3RV2011, 3RV2111, 3RV2311, 3RV2411 3RV2011, 3RV2111, 3RV2311, 3RV2411 FLA2) max. FLA2) max. 16 A,480 V 16 A,480 V 12.5 A, 600 V 12.5 A, 600 V 115 115 200 200 230 230 460 460 575/600 575/600 1 1 2 2 2 2 ----- Size S0 Size S0 3RV2021, 3RV2121, 3RV2321, 3RV2421 3RV2021, 3RV2121, 3RV2321, 3RV2421 2) FLA2) max. FLA max. 40 A, 480 V 40 A, 480 V 115 115 200 200 230 230 460 460 575/600 575/600 3 3 5 5 7 1/2 7 -- 1/2 ---- 5 5 10 10 10 10 30 30 --- Size S2 3RV2031, 3RV2131, 3RV2331, 3RV2032, 3RV2332 FLA 2) MAX. 65A 600V NEMA size 2 Size S3 Size S3 115/120 200/208 230/240 460/480 575/600 5 10 15 — — 10 20 25 50 60 a) with max 225A Class J fuse b) with max 250A Class J fuse 3RV10 41/3RV10 42, 3RV11 42, 3RV13 41/3RV13 42 3RV10 41/3RV10 42, 3RV11 42, 3RV13 41/3RV13 42 2) max. 99 A, FLA2) max. 99 A, FLA 600 V 600 V NEMA size 3 NEMA size 3 1) 1) 2) 2) 3) 3) 4) 4) 115 115 200 200 230 230 460 460 575/600 575/600 Approval of the 3RV as a Manual Motor Controller can be found Approval of the 3RV as a Manual Motor Controller can be found under the following file numbers: under the following file numbers: • UL File No. 47705, CCN: NLRV, • UL File No. 47705, CCN: NLRV, • CSA Master Contract 165071, Product Class: 3211 05. • CSA Master Contract 165071, Product Class: 3211 05. 7 1/2 7 201/2 20 20 20 ----- --30 30 40 40 75 75 100 100 14 17 20 25 32 36 40 45 52 59 65 3RV2031 65 65 65 65 65 65 65 65 65 65 a) 65 b) 16 16 20 20 25 25 32 32 40 40 50 50 63 63 75 75 90 90 100 100 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 3RV2032 100 100 100 100 100 100 100 100 100 100 a) 100 b) 3RV2031 65 65 65 65 65 65 65 65 65 65 a) 65 b) 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 3RV2032 100 100 100 100 100 100 100 100 100 100 a) 100 b) 3RV2031 25 25 25 25 25 25 22 22 22 20 a) 20 b) 3RV2032 25 25 25 25 25 25 22 22 22 25 a) 25 b) 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 30 10 10 10 10 hp rating = Power rating in horse power (maximum motor rating). hp rating = Power rating in horse power (maximum motor rating). FLA = Full Load Amps/Motor full load current. FLA = Full Load Amps/Motor full load current. Corresponds to "short-circuit breaking capacity" according to UL/CSA. Corresponds to "short-circuit breaking capacity" according to UL/CSA. The values in brackets only apply to 3RV2.23 motor starter protectors. The values in brackets only apply to 3RV2.23 motor starter protectors. 1/18 Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog 3RV Motor Starter Protectors • Revised • 10/25/15 SIRIUS General Data 3RV up to 100 A (Domestic applications) 3RV motor starter protectors as "Manual Motor Controllers Suitable for Tap Conductor Protection in Group Installations" The application as "Manual Motor Controllers Suitable for Tap protector according to UL 489 can be used. Conductor Protection in Group Installations" is only available These devices must be dimensioned according to the National from UL. Electrical Code. CSA does not recognize this as approval! motor starter 3RV motor starter protectors "ManualWhen Motorthe Controllers Suitable for Tap Conductor Protection in Group Installations" The 3RV motor starter protectors are approved as "Manual protector is used as a "Manual Motor Controller Suitable for Tap Motor Controllers Suitable for Tap The application as "Manual Motor Controllers itSuitable for Tap protector according to UL 489 canConductor be used. Protection in Conductor Protection in Group Installations", must always be Group Installations" the following file number: Conductor Protection in Group Installations" is only These devices mustunder be dimensioned according to the National combined with upstream short-circuit protection. Asavailable short-cirfrom UL. •Electrical UL File Code. No. 47705, CCN: NLRV. cuit-protection device, approved fuses or a motor starter CSA does not recognize this approval! When the motor starter The 3RV motor starter protectors are approved as "Manual protector is used as a "ManualhpMotor for Tap 1) for FLA2) Suitable Motor starter ratingController Rated 240 V AC Up tofor 480Y/277V AC UpProtection to 600Y/347V Motor Controllers Suitable Tap Conductor in AC Conductor Installations", it must always In current be max. protectors Protection in Group UL UL the following file UL Group Installations" under number: combined with upstream short-circuit protection. As short-cir3) I•bcUL Ibc3) NLRV. Ibc3) File No. 47705, CCN: cuit-protection device, approved fuses or a motor starter Type Motor starter Size S00 protectors 3RV20 11 V FLA2) max.16 A, Type 480 Y / 277 V 115/120 V 200/208 1 1-phase 2 2 3-phase 3 FLA2) max.16 A, 480 Y / 277 V 230/240 460/480 575/600 115/120 200/208 2 --1 2 5 10 10 2 3 230/240 460/480 575/600 2 --- 5 10 10 Size S00 NEMA size 0 3RV20 11 NEMA size 0 Size S0 1-phase 1) 3-phase2) hp rating for FLA max. A Rated current In 0.16 ... 0.8 1 1.25 A 2 2.5 3.2 ... 0.8 0.16 1 4 1.25 5 6.3 2 8 2.5 16 3.2 4 5 0.63 ... 1.6 6.3 2 2) 8 FLA max. 115/120 2 5 2.5 16 200/208 3 7.5 25 A, 480 Y / 277 V 3.2 Size S0 230/240 3 10 4 12.5 A, 600 V 460/480 3 20 5 3RV20 21 0.63 ... 1.6 575/600 — — NEMA size 1 2 6.3 115/120 2 5 2.5 FLA2) max. 8 200/208 3 7.5 10 25 A, 480 Y / 277 V 3.2 12.5 12.5 A, 600 V 230/240 3 10 4 25 460/480 3 20 5 NEMA size 1 575/600 — — 32 6.3 8 Size Size S2 S2 10 3RV10 31 1614 12.5 2017 3RV2031, 3RV2032, 3RV2431 25 115 3 -25 FLA2) max. 3220 50 V 65A 200 15 3225 FLAA,2)600 MAX. 115/120 751/2 10 Size S2 NEMA 230 20 4032 600V size 2 200/208 10 10 20 460 40 4536 3RV10 31 2 16 NEMA size 230/240 --15 25 575/600 -50 50 20 460/480 — 50 40 2) max. 115 3 -25 FLA Size S3 575/600 7— 60 45 50 A, 600 V 200 1/2 15 32 3RV10 4. 1652 NEMA size 2 230 10 20 40 20 59 460 -- 1/2 40 45 115/120 7 -25 FLA2) max. 575/600 -50 5065 200/208 20 30 100 A, 480 V 32 Size S3 V 75 A, 600 230/240 20 40 40 460/480 -75 50 3RV10 4. 16 NEMA size 3 575/600 -75 20 63 115/120 7 1/2 -25 FLA2) max. 75 200/208 20 30 90 100 A, 480 V 32 100 75 A, 600 V 230/240 20 40 40 460/480 -75 50 1) NEMA size 3 575/600 -75 hp rating = Power rating in horse power (maximum motor rating). 63 2) 75 FLA = Full Load Amps/Motor full load current. 90 3) Complies with "short-circuit breaking capacity" according to UL. 100 3RV20 21 1) hp rating = Power rating in horse power (maximum motor rating). 2) FLA = Full Load Amps/Motor full load current. 3) Complies with "short-circuit breaking capacity" according to UL. Siemens Industry, Inc. Industrial Controls Catalog kA 240 V AC kA Up to 480Y/277V AC kA Up to 600Y/347V AC UL 65 3) I65 bc 65 kA 65 65 65 65 65 65 65 65 65 65 UL 65 3) Ibc 65 65 kA 65 65 65 65 65 65 65 65 65 65 UL 30 3) I30 bc 30 kA 30 30 30 30 30 30 30 30 30 — 30 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 50 65 65 3RV2031 65 65 65 65 65 65 65 50 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 50 65 65 3RV2031 65 65 65 65 65 65 65 50 65 65 65 65 65 65 65 65 65 65 65 65 65 65 30 65 65 65 30 65 65 65 65 65 65 65 65 65 65 30 30 30 30 30 30 30 — 30 30 30 30 30 30 30 30 30 — 30 — 30 30 3RV2031 30 25 30 25 — 25 25 — 25 25 25 25 25 25 22 25 22 25 30 22 25 30 -25 30 25 -30 30 30 30 30 30 30 -30 -30 30 3RV2032 100 100 100 100 100 100 100 100 100 100 100 65 65 65 65 Product Category: IEC 65 65 65 65 3RV2032 100 100 100 100 100 100 100 100 100 42 42 3RV2032 25 25 25 25 25 25 22 22 22 --- 30 30 --- 1/19 3RV Motor Starter Protectors • Revised • 10/25/15 General Data 3RV up to 100 A (Domestic applications) SIRIUS 3RV motor starter protectors as "Self-Protected Combination Motor Controllers (Type E)" when the device is used as a “Self-Protected Combination Motor UL 508/UL 60947-4-1 approval demands 1-inch clearance and Controller”. 2-inch creepage distance at line side for “Self-Protected Combination 3RV motor starter protectors as "Self-Protected Combination Motor Controllers (Type E)" Motor Controller Type E”. The 3RV20 motor starter protectors are approved as “Self-Protected Combination Motor Controllers” under the following file numbers: Therefore, 3RV20 motor starter protectors of sizes S00 to S2 are approved according to UL 508/UL 60947-4-1 in combination with the • UL File No. E156943, CCN: NKJH terminal blocks listed below. • CSA Master Contract 165071, Product Class: 3211 08 CSA does not require these extended clearances and creepage distances. According to CSA, these terminal blocks can be omitted Motor starter protectors hp rating1) for FLA2) max. Rated current In Type V Motor starter Size S00 protectors 3RV2011 + 3RV29 28-1H4) 5) Type2) V FLA max. 16 A 115 Size S00 480 V 200 3RV2011 + 3RV29 28-1H4) 5) 230 NEMA size 0 230 FLA2) max. 16 A 115 575/600 480 V 200 1-phase 3-phase hp rating1) for FLA2) max. NEMA size 0 Size S0 230 2304) 5) 3RV2021 + 3RV29 28-1H 575/600 2) FLA max. 115 Size S0 2004) 5) 25 A, 480 V 3RV2021 + 3RV29 28-1H 12.5 A, 600 V 230 460 2) max. FLA 115 NEMA size 1 575/600 200 25 A, 480 V 12.5 A, 600 V 230 460 NEMA size 1 575/600 1-phase 1 2 2 — 1 — 2 2 — — 2 3 3 — 2 — 3 3 — — 3-phase 2 3 5 10 2 10 3 5 10 10 5 7.5 10 20 5 — 7.5 10 20 — Size S2 Size S2 3RV2031/3RV2032 + 3RV2938-1K 4) 3RV2031/3RV2032 + 3RV2938 2) MAX. 65A FLA 2) 115/120 FLA 115 max. Size S2 600V 200/208 50 A, 600 V 200 3RV2031/3RV2032 + 3RV2938 NEMA size 230/240 NEMA size 22 230 460/480 460 2) FLA max. 115 575/600 575/600 50 A, 600 200 Size S3 V NEMA size 2 230 4) 3RV1041 + 3RT1946-4GA07 460 575/600 2) FLA max. 115 Size S3 200 4) 100 A, 480 V 3RV1041 + 3RT1946-4GA07 230 75 A, 600 V 460 FLA2) max. 115 NEMA size 3 575/600 200 100 A, 480 V 230 75 A, 600 V 460 NEMA size 3 575/600 5 3 10 7 1/2 15 10 — -3 -— 7 1/2 10 --10 20 20 -10 -20 20 --- 10 -20 15 25 20 50 40 -50 60 15 20 40 50 -30 40 75 -75 30 40 75 75 A Rated current In 0.16 ... 12.5 A 16 Up to 240 V AC UL/CSA Ibc3) kA Up to 240 V AC UL/CSA Ibc3) 65 kA 65 Up to 480 Y/277 V AC UL/CSA Ibc3) kA Up to 480 Y/277 V AC UL/CSA Ibc3) 65 kA 65 UL/CSA 30 kA — 0.16 ... 12.5 16 65 65 65 65 30 — 0.63 ... 1.6 2 2.5 65 65 65 65 65 65 30 30 30 3.2 0.63 ... 1.6 4 2 5 2.5 6.3 3.2 8 4 10 5 12.5 6.3 16 8 20 10 22 12.5 25 16 32 20 22 25 14 32 17 16 20 20 25 25 32 32 16 36 40 20 40 45 25 50 45 32 52 40 59 16 45 20 65 50 25 32 16 40 20 50 25 63 32 75 40 90 50 100 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 50 65 65 3RV2031 65 65 50 65 65 6565 6565 65 65 65 6565 65 6565 65 6565 6565 65 6565 6565 65 3RV2032 100 100 100 100 100 100 100 100 100 100 100 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 50 65 65 3RV2031 6565 50 65 65 6565 6565 65 65 65 6565 65 6565 65 6565 6565 65 2065 2065 65 65 65 65 65 65 65 65 65 65 65 65 65 65 3RV2032 100 100 100 100 100 100 100 100 100 30 30 Up to 600 Y/347 V AC UL/CSA Ibc3) kA Up to 600 Y/347 V AC 30 30 30 30 30 30 30 30 30 30 30 30 30 30 — 30 — 30 — 30 — — — — 3RV2031 — 25 — 25 25 25 25 25 25 25 25 25 25 25 25 22 25 25 25 22 25 22 25 —30 25 —30 25 30 Ibc3) 3RV2032 25 25 25 25 25 25 22 22 22 — — 30 30 30 30 30 30 30 30 30 30 — 30 — 63 65 65 30 Lateral auxiliary65 switch with Transverse auxiliary Transverse 75 65 30 switch with auxiliary switch with 1 NO + 1 NC, 2 NO, 90 65 2 NC, 65 — 1 changeover contact 1 2 NO + 2 NC and signalling switch 100 65 65 —NO + 1 NC, 2 NO Max. ratedof voltage • to NEMA u AC V 600 250 Ratings the auxiliary switches Lateral auxiliary switch with Transverse auxiliary Transverse AC V 250 and alarm switches • to NEMA s switch with auxiliary switch with 1600 NO + 1 NC, 2 NO, 2 NC, 1 1 NO + 1 NC, 2 NO 210NO + 2 NC and signalling switch Uninterrupted current A 5 changeover contact 2.5 Breaking capacity A600 B600 C300 Max. rated voltage • to NEMA u AC V 600 250 Q300 R300 R300 • to NEMA s AC V 600 250 1) hp rating = Power rating in horse power (maximum motor rating). 3) Corresponds to "short-circuit breaking capacity" according to UL/CSA. U n i n t e r r u p t e d c u r r e n t A 10 5 2.5 2) FLA = Full Load Amps/Motor full load current. 4) Not required for CSA. Breaking capacity A600 B600 C300 5) Alternatively, the 3RV2928-1K phase barrier can also be used. Q300 R300 R300 Ratings of the auxiliary switches and alarm switches 1) 2) hp rating = Power rating in horse power (maximum motor rating). FLA = Full Load Amps/Motor full load current. 3) 4) 5) 1/20 Corresponds to "short-circuit breaking capacity" according to UL/CSA. Not required for CSA. Alternatively, the 3RV2928-1K phase barrier can also be used. Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog SIRIUS 3RV Motor Starter Protectors • Revised • 10/25/15 General Data 3RV17/27 and 3RV18/28 circuit breakers 3RV17/27 and 3RV18/28 circuit breakers These circuit breakers are approved according to UL 489 and CSA C22.2 No. 5-02 for 100 % rated current (100 % rated breaker). They can be used therefore as upstream short-circuit protective devices for "Manual Motor Controllers" and "Manual Motor Controllers Suitable for Tap Conductor Protection in Group Installations". Circuit breakers Rated current In Type The 3RV17/27 and 3RV18/28 circuit breakers are approved under the following file numbers: • UL File No. E235044, CCN: DIVQ, • CSA Master Contract 165071, Product Class: 1432 01. A 240 V AC UL/CSA Ibc1) kA 480 Y/277 V AC UL/CSA Ibc1) kA 480 V AC UL/CSA Ibc1) kA 600 Y/347 V AC UL/CSA Ibc1) kA 0.16 … 1.25 1.6 2 2.5 3.2 4 5 6.3 8 10 12.5 15 20 22 65 65 65 65 65 65 65 65 65 65 65 65 50 50 65 65 65 65 65 65 65 65 65 65 65 65 50 50 65 65 65 65 65 65 65 65 65 65 65 65 50 50 10 10 10 10 10 10 10 10 10 10 10 ---- 10 15 20 25 30 35 40 45 50 60 70 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 65 ------- 20 20 20 20 20 20 20 20 20 20 10 Size S00/S0 3RV27 11 / 3RV28 11 3RV27 21 / 3RV28 21 Size S3 3RV17 42 1) Complies with "short-circuit breaking capacity" according to UL. Siemens Industry, Inc. Industrial Controls Catalog Product Category: IEC 1/21 3RV Motor Starter Protectors • Revised • 10/25/15 General Data 3RV up to 100 A (Export applications) SIRIUS Technical specifications Short-circuit breaking capacity Icu, Ics acc. to IEC 60947-2 This table shows the rated ultimate short-circuit breaking capacity Icu and the rated service short-circuit breaking capacity Ics of the 3RV2 motor starter protectors/circuit breakers with different inception voltages dependent of the rated current In of the motor starter protectors/circuit breakers. Power can be supplied to the motor starter protectors/circuit breakers via the terminals at the top or at the bottom without restricting the rated data. If the short-circuit current at the place of installation exceeds the rated short-circuit breaking capacity of the motor starter protector/circuit breaker as specified in the Motor starter protectors/circuit breakers Rated current Up to 240 V AC1) In table, a back-up fuse is required. It is also possible to install an upstream motor starter protector/circuit breaker with a limiter function. The maximum rated current for the back-up fuse is specified in the tables. The rated ultimate short-circuit breaking capacity then applies as specified on the fuse. Fuseless construction Motor starter protector contactor combinations for short-circuit currents up to 150 kA can be ordered in the form of fuseless load feeders according to Chapter 6. Up to 400 V1)/415 V AC2) Up to 440 V1)/460 V AC2) Up to 500 V1)/525 V AC2) Up to 690 V AC1) (these values do not apply to 3RV17 42 circuit breakers) Icu Ics Max. fuse Icu (gL/gG) Ics Max. fuse Icu (gL/gG)3) Ics Max. fuse Icu (gL/gG)3) Ics Max. fuse Icu (gL/gG)3) Ics Max. fuse (gL/gG)3)4) Type A kA kA A kA kA A kA kA A kA kA A kA kA A 3RV2.11 0.16 ... 1 1.25; 1.6 2; 2.5 100 100 100 100 100 100 ° ° ° 100 100 100 100 100 100 ° ° ° 100 100 100 100 100 100 3.2; 4 5; 6.3 8 100 100 100 100 100 100 ° ° ° 100 100 50 100 ° 100 ° 12.5 ° 50 50 50 10 10 50 ° ° ° ° ° 63 100 100 100 100 100 42 100 100 100 100 100 42 ° ° ° ° ° 63 100 100 10 10; 6 6 6 100 100 10 10; 4 4 4 ° ° 25 32 32 50 10 12 16 100 100 100 100 100 100 ° ° ° 50 50 55 12.5 ° 12.5 ° 30 100 50 50 50 50 50 10 80 80 80 42 42 10 42 42 5 63 80 80 6 4 4 4 4 4 50 63 63 16 20 100 100 100 100 ° ° 55 55 25 25 100 125 50 50 10 10 80 80 10 10 5 5 22 25 28 100 100 100 100 100 100 ° ° ° 55 55 55 25 25 25 125 125 125 50 50 30 10 10 10 100 100 125 10 10 10 5 5 5 80 80 80 80 100 4 4 4 4 4 2 2 2 2 2 63 63 63 63 100 32 36 40 100 100 100 100 100 100 ° ° ° 55 20 20 25 10 10 125 125 125 30 12 12 10 8 8 125 125 125 10 6 6 5 3 3 100 100 100 4 3 3 2 2 2 100 100 100 14; 17 20 25 32; 36 100 100 100 100 100 100 100 100 ° ° ° ° 65 65 65 65 30 30 30 30 100 100 100 125 50 50 50 50 25 25 15 15 100 100 100 125 12 12 12 10 6 6 6 5 63 80 80 100 5 5 5 4 3 3 3 2 63 80 80 100 40; 45 52 59 ... 80 100 100 ° 100 100 ° Values on request 65 65 30 30 160 160 50 50 15 15 125 125 10 10 5 5 100 125 4 4 2 2 100 125 14; 17 20; 25 32 ... 45 52 100 100 100 100 100 100 100 100 50 50 50 50 ° ° ° ° 65 65 65 65 30 30 30 30 100 100 125 125 18 18 15 15 10 10 8 8 63 80 100 125 8 8 6 6 5 5 4 4 63 80 100 125 59 ... 80 Values on request 40 50 63 100 100 100 100 100 100 ° ° ° 50 50 50 25 25 25 125 125 160 50 50 50 20 20 20 125 125 160 12 12 12 6 6 6 100 100 100 6 6 6 3 3 3 63 80 80 75 90; 100 100 100 100 100 ° ° 50 50 25 25 160 160 50 50 20 20 160 160 8 8 4 4 125 125 5 5 3 3 100 125 Size S00 Size S0 3RV2.21 Size S2 3RV2.31 Size S2, with increased switching capacity 3RV2.32 Size S3 3RV1. 41 100 100 100 100 ° ° ° ° Short-circuit resistant up to at least 50 kA ° 1) 2) 3) No back-up fuse required, since short-circuit resistant up to 100 kA 10 % overvoltage. 5 % overvoltage. Back-up fuse only required if the short-circuit current at the place of installation > Icu. 1/22 4) Alternatively, fuseless limiter combinations for 690 V AC can also be used. Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog 3RV Motor Starter Protectors • Revised • 10/25/15 SIRIUS General Data 3RV up to 100 A (Export applications) Short-circuit breaking capacity IcuIT in the IT system (IT network) according to IEC 60947-2 3RV motor starter protectors are suitable for operation in IT systems. Values valid for triple-pole short-circuit are Icu up to Ics. In case of double ground fault on different phases at the input and output side of a motor starter protector, the special short-circuit breaking capacity IcuIT applies. The specifications in the table below apply to 3RV motor starter protectors. In the colored areas, IcuIT is 100 kA, or in some ranges it is 50 kA. Therefore the motor starter protectors are short-circuit resistant in these ranges. If the short-circuit current at the place of installation exceeds the rated short-circuit breaking capacity of the motor starter protector as specified in the table, a back-up fuse is required. The maximum rated current for the back-up fuse is specified in the tables. The rated short-circuit breaking capacity then applies as specified on the fuse. Motor starter protectors Rated current Up to 240 V AC1) In IcuIT Max. fuse (gL/gG)3) Up to 400 V1)/415 V AC2) IcuIT Max. fuse (gL/gG)3)4) IcuIT Max. fuse (gL/gG)3) IcuIT Max. fuse (gL/gG)3) Type A kA A kA A kA A kA A 3RV20, 3RV26 11-0BD10 0.16 ... 0.63 0.8; 1 1.25; 1.6 100 100 100 ° ° ° 100 100 100 ° ° ° On request On request On request On request 2; 2.5 3.2; 4 5; 6.3 100 100 100 ° ° ° 8 8;4 4 25 32 32:50 8; 10 12.5 16 100 100 55 ° ° 80 4 4 4 50 63 63 16 20 22 55 55 55 2 2 2 50 50 50 1.5 1.5 1.5 40 50 50 55 55 55 4 4 4 4 2 2 63 63 63 25 28 32 80 80 80 80 80 80 63 63 63 2 2 2 50 63 63 1.5 1.5 1.5 50 63 63 36 40 20 20 80 80 2 2 63 63 2 2 63 63 1.5 1.5 63 63 14...25 32...45 52 59 ... 80 100 ° 100 ° 100 ° Values on request 8 6 4 100 125 160 6 4 3 80 100 125 4 3 2 63 80 100 14 ... 25 32 ... 45 52 100 100 100 8 6 6 100 125 160 6 6 6 80 100 125 4 4 4 63 80 100 59 ... 80 Values on request 40 50 63 50 50 50 125 125 160 10 8 6 63 80 80 5 3 3 50 63 63 5 3 3 50 63 63 75 90; 100 50 50 160 160 5 5 100 125 2 2 80 100 2 2 80 100 Size S00 Size S0 3RV2.21 Size S2 3RV2.31 Size S2, with increased switching capacity 3RV2.32 Size S3 3RV1. 41 ° ° ° Up to 500 V1)/525 V AC2) Up to 690 V AC1) 5) Short-circuit resistant up to at least 50 kA ° No back-up fuse required, since short-circuit resistant up to 100 kA 1) 10 % overvoltage. 2) 5 % overvoltage. 3) Back-up fuse only required, if short-circuit current at the place of installation > IcuIT. 4) 5) Alternatively, fuseless limiter combinations for 690 V AC can also be used. Over-voltage category II applies for applications on IT systems > 600V Siemens Industry, Inc. Industrial Controls Catalog Product Category: IEC 1/23 3RV Motor Starter Protectors • Revised • 10/25/15 General Data 3RV up to 100 A SIRIUS Technical data Rules for mounting motor starter protectors/circuit breakers When mounting MSP’s, the following clearance must be maintained to grounded or live parts. SIRIUS MSP Clearance to grounded or live parts Type size Y mm X mm 3RV2.1 S00 up to 690 V 30 70 9 3RV2. 2 S0 2) up to 500 V up to 690 V 30 50 1) 90 90 9 30 3RV2. 3 S2 up to 690 V 50 — 10 3RV1. 4 S3 up to 240 V up to 440 V up to 500 V up to 690 V 50 70 110 150 167 167 167 167 10 10 10 30 3RV17 42 S3 up to 240 V up to 400 V 90 90 167 167 10 10 at the side Z mm Minimum clearance between MSP’s and grounded or live parts 1) Up to and including the setting range of 32 A. For the 36/40 A setting range the clearance is 70 mm. 2) In conjunction with the type E terminal block 3RV2928-1H the applicable lateral clearance is 30 mm for all voltages. Standard mounting for S0, S2 and S3 Wiring module Size S0: 3RV19 15-1AB Size S2: 3RV19 35-1A Size S3: 3RA19 43-3D (Caution: The wiring module demands 10 mm spacing between the MSPs) Line side 1/24 Load side Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog © Siemens AG 2015 3RV Motor Starter Protectors • Revised • Motor Starter Protectors/Circuit Breakers SIRIUS 10/25/15 General Data SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 80 A 3RV up to 80 A General data General data 3RV2.1. 3RV2.2. 3RV2.3. 3RV27, 3RV28 Size S00 S0 S2 S00, S0 45 x 97 x 91 45 x 106 x 91 45 x 97 x 91 45 x 119 x 91 55 x 140 x 149 -- 45 x 144 x 92 -- Yes Yes Yes Yes -- Yes Yes -- Yes Yes -- --Yes 40 80 22 W D Dimensions (W x H x D) • Screw terminals • Spring-type terminals H Type mm mm Standards • IEC 60947-1, EN 60947-1 (VDE 0660 Part 100) • IEC 60947-2, EN 60947-2 (VDE 0660 Part 101) • IEC 60947-4-1, EN 60947-4-1 (VDE 0660 Part 102) • UL 508/UL 60947-4-1, CSA C22.2 No. 14/CSA C22.2 No. 60947-4-1 • UL 489, CSA C22.2 No. 5 3 Number of poles A 16 In: 0.16 ... 32 A °C °C In: 36 ... 40 A °C In: 14 ... 80 A °C –50 ... +80 –20 ... +70 -(current reduction above +60 °C) -–20 ... +40 -(the devices must not be mounted side-by-side and they must not be assembled with link modules with contactors. A lateral clearance of 9 mm is required.) -–20 ... +70 -(current reduction above +60 °C) Max. rated current In max (= max. rated operational current Ie) 7 Permissible ambient temperature • Storage/transport • Operation Permissible rated current at inside temperature of control cabinet • +60 °C • +70 °C % % 100 87 Permissible rated current at ambient temperature of enclosure (applies for motor starter protector/circuit breaker inside enclosure ≤ 32 A) • +35 °C % • +60 °C % 100 87 Rated operational voltage Ue • Acc. to IEC • Acc. to UL/CSA V AC V AC 690 (when a molded-plastic enclosure is used only 500 V) 600 Rated frequency Hz 50/60 Rated insulation voltage Ui V 690 Rated impulse withstand voltage Uimp kV 6 Utilization category • IEC 60947-2 (motor starter protector/circuit breaker) • IEC 60947-4-1 (motor starter) On request 100 87 A AC-3 Acc. to IEC 60947-4-1 10 10/20 -- kA kA kA 10 10 10 On request 10 10 10 In: 0.16 ... 0.63 A In: 0.8 ... 6.3 A In: 8 ... 16 A W W W 5 6 7 ---- 5 6 7 In: 16 A W -- 7 10 7 In: 17 ... 25 A In: 28 ... 32 A In: 36 ... 40 A In: 45 ... 52 A In: ... 80 A W W W W W ------ 8 11 14 --- 12 14 15 17 On request 8 ----- Shock resistance Acc. to IEC 60068-2-27 g/ms 25/11 (square and sine pulse) Degree of protection Acc. to IEC 60529 Touch protection Acc. to EN 50274 Temperature compensation Acc. to IEC 60947-4-1 Phase failure sensitivity Acc. to IEC 60947-4-1 Trip class CLASS DC short-circuit breaking capacity (time constant t = 5 ms) • 1 conducting path 150 V DC • 2 conducting paths in series 300 V DC • 3 conducting paths in series 450 V DC Power loss Pv for each motor starter protector/circuit breaker Dependent on the rated current In (upper setting range) P R per conducting path = -------------Ι 2× 3 IP20 Finger-safe for vertical contact from the front °C –20 ... +60 Yes (only for 3RV23 motor starter protectors) Explosion protection – Safe operation of motors with "increased safety" type of protection Yes (only for 3RV20 motor starter protectors) EC type test certificate number according to directive 94/9/EC (ATEX) DMT 02 ATEX F 001 Siemens Industry, Inc. Industrial Controls Catalog 7/16 Product Category: IEC Siemens IC 10 · 2015 II (2) GD On request No No 1/25 © Siemens AG 2015 3RV Motor Starter Protectors General Data • Revised • Motor Starter Protectors/Circuit Breakers SIRIUS 10/25/15 SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 80 A 3RV up to 80 A General data Conductor cross-sections of main circuit Type 3RV2.11 3RV2.21 3RV2.31-4B1., 3RV2.31-4D.1., 3RV2.31-4E.1., 3RV2.31-4P.1., 3RV2.31-4S.1., 3RV2.31-4T.1., 3RV2.31-4U.1., 3RV2.31-4V.1. Size S00 S0 S2 S00, S0 Connection type 3RV2.31-4J.1., 3RV27, 3RV28 3RV2.31-4K.1., 3RV2.31-4R.1., 3RV2.31-4W.1., 3RV2.31-4X.1., 3RV2431-4VA1., 3RV2.32 Screw terminals Terminal screw M3, Pozidriv size 2 M4, Pozidriv size 2 M6, Pozidriv size 2 M4, Pozidriv size 2 Operating devices mm ∅ 5 ... 6 ∅ 5 ... 6 ∅ 5 ... 6 ∅ 5 ... 6 Prescribed tightening torque Nm 0.8 ... 1.2 2 ... 2.5 3.0 ... 4.5 2.5 ... 3 • Solid or stranded mm2 2 x (0.75 ... 2.5)1), 2 x (1 ... 2.5)1), 2x4 2 x (2.5 ... 10)1) 2 x (1 ... 25)1), 1 x (1 ... 35)1) 2 x (1 ... 35)1), 1 x (1 ... 50)1) 2 x (1 ... 10)1), max. 1 x 25 • Finely stranded with end sleeve (DIN 46228-1) mm2 2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1) 2 x (1 ... 2.5)1), 2 x (2.5 ... 6)1), 1 x 10 2 x (1 ... 16)1), 1 x (1 ... 25)1) 2 x (1 ... 25)1), 1 x (1 ... 35)1) 1 x (1 ... 16), max. 6 + 16 • AWG cables, solid or stranded AWG 2 x (20 ... 16)1), 2 x (18 ... 12)1) 2 x (16 ... 12)1), 2 x (14 ... 8)1) 2 x (18 ... 3)1), 1 x (18 ... 2)1) 2 x (18 ... 2)1), 1 x (18 ... 1)1) 2 x (14 ... 10) Conductor cross-sections (min./max.), 1 or 2 conductors can be connected Spring-type terminals Connection type mm 3.0 x 0.5 and 3.5 x 0.5 • Solid or stranded mm2 2 x (0.5 ... 4) 2 x (1 ... 10) -- • Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5) 2 x (1 ... 6) -- • Finely stranded with end sleeve (DIN 46228-11) mm2 2 x (0.5 ... 2.5) 2 x (1 ... 6) -- • AWG cables, solid or stranded AWG 2 x (20 ... 12) 2 x (18 ... 8) -- Max. external diameter of the conductor insulation mm 3.6 3.6 -- Operating devices 7 Conductor cross-sections (min./max.), 1 or 2 conductors can be connected Ring terminal lug connections Connection type Terminal screw M3, Pozidriv size 2 M4, Pozidriv size 2 -- Operating devices mm ∅ 5 ... 6 ∅ 5 ... 6 -- Prescribed tightening torque Nm 0.8 ... 1.2 2 ... 2.5 -- mm d2 = min. 3.2, d3 = max. 7.5 d2 = min. 4.3, d3 = max. 12.2 -- Usable ring terminal lugs • DIN 46234 without insulation sleeve d3 d2 • DIN 46237 with insulation sleeve • JIS C2805 Type R without insulation sleeve I201_12740 • DIN 46225 without insulation sleeve • JIS C2805 Type RAV with insulation sleeve • JIS C2805 Type RAP with insulation sleeve 1) If two different conductor cross-sections are connected to one clamping point, both cross-sections must be in the range specified. 1/26 Siemens Industry, Inc. Industrial Controls Catalog Product Category: IEC Siemens IC 10 · 2015 7/19 © Siemens AG 2015 SIRIUS • Revised • 10/25/15 3RV Motor Starter Protectors Motor Starter Protectors/Circuit Breakers General Data SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 80 A 3RV up to 80 A General data 3RV2.1. 3RV2.2. 3RV2.3. 3RV27, 3RV28 S00 S0 S2 S00, S0 Front transverse auxiliary switches Switching capacity for different voltages Rated operational current Ie 1 CO 1 NO + 1 NC, 2 NO • At AC-15, alternating voltage - 24 V - 230 V A A 4 3 2 0.5 • At AC-12 = Ith, alternating voltage - 24 V - 230 V A A 10 10 2.5 2.5 • At DC-13, direct voltage L/R 200 ms - 24 V - 48 V - 60 V - 110 V - 220 V A A A A A 1 --0.22 0.1 1 0.3 0.15 --- V mA 17 1 Minimum load capacity Front transverse solid-state compatible auxiliary switches Switching capacity for different voltages 1 CO Alternating voltage V 125 Rated operational current Ie/AC-14 at Ue = 125 V A 0.1 Direct voltage L/R 200 ms V 60 Rated operational current Ie/DC-13 at Ue = 60 V A 0.3 V mA 5 1 Rated operational voltage Ue Minimum load capacity 7 Rated operational voltage Ue Lateral auxiliary switches with signaling switch Switching capacity for different voltages: Lateral auxiliary switch with 1 NO + 1 NC, 2 NO, 2 NC, 2 NO + 2 NC Signaling switch Rated operational current Ie • At AC-15, alternating voltage - 24 V - 230 V - 400 V - 690 V A A A A 6 4 3 1 • At AC-12 = Ith, alternating voltage - 24 V - 230 V - 400 V - 690 V A A A A 10 10 10 10 • At DC-13, direct voltage L/R 200 ms - 24 V - 110 V - 220 V - 440 V A A A A 2 0.5 0.25 0.1 V mA 17 1 Minimum load capacity Auxiliary releases Power consumption Undervoltage releases Shunt releases • During pick-up - A C vo lt a g es - DC voltages VA/W W 20.2/13 20 20.2/13 13 ... 80 • During uninterrupted duty - A C vo lt a g es - DC voltages VA/W W 7.2/2.4 2.1 --- • T ripping V 0.35 ... 0.7 x Us 0.7 ... 1.1 x Us • Pick-up V -- Opening time maximum 0.85 ... 1.1 x Us ms 20 A 10 A 6 (prospective short-circuit current < 0.4 kA) Response voltage Short-circuit protection for auxiliary and control circuits Melting fuses operational class gG Miniature circuit breakers C characteristic Siemens Industry, Inc. Industrial Controls Catalog 1/27 Product Category: IEC Siemens IC 10 · 2015 7/17 © Siemens AG 2015 3RV Motor Starter Protectors • Revised • 10/25/15 Motor Starter General DataProtectors/Circuit Breakers SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to 80 A 3RV SIRIUS up to 80 A General data Conductor cross-sections for auxiliary and control circuits Type 3RV2.11 3RV2.21 3RV2.31, 3RV2.32 3RV27, 3RV28 Size S00 S0 S2 Connection type Terminal screw M3, Pozidriv size 2 Operating devices mm ∅ 5 ... 6 Prescribed tightening torque Nm 0.8 ... 1.2 Conductor cross-sections (min./max.), 1 or 2 conductors can be connected • Solid or stranded mm 2 2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1) • Finely stranded with end sleeve (DIN 46228-1) mm2 2 x (0.5 ... 1.5)1), 2 x (0.75 ... 2.5)1) • AWG cables, solid or stranded AWG 2 x (18 ... 14)1), 2 x (20 ... 16)1) Connection type Spring-type terminals Operating devices mm 3.0 x 0.5 and 3.5 x 0.5 Conductor cross-sections (min./max.), 1 or 2 conductors can be connected • Solid or stranded mm 2 2 x (0.5 ... 2.5) • Finely stranded without end sleeve mm2 2 x (0.5 ... 2.5) • Finely stranded with end sleeve (DIN 46228-1) mm2 2 x (0.5 ... 1.5) • AWG cables, solid or stranded AWG 2 x (20 ... 14) Max. external diameter of the conductor insulation mm 3.6 Ring terminal lug connections Connection type M3, Pozidriv size 2 Tightening torque • DIN 46234 without insulation sleeve d3 d2 mm ∅ 5 ... 6 Nm 0.8 ... 1.2 mm d2 = min. 3.2, d3 = max. 7.5 • DIN 46225 without insulation sleeve • DIN 46237 with insulation sleeve • JIS C2805 Type RAV with insulation sleeve • JIS C2805 Type RAP with insulation sleeve 1) I201_12740 • JIS C2805 Type R without insulation sleeve If two different conductor cross-sections are connected to one clamping point, both cross-sections must be in the range specified. Terminals for "Self-Protected Combination Motor Controllers (Type E) according to UL 508/UL 60947-4-1" Type 3RV2928-1H Prescribed tightening torque Nm 2.5 ... 3 • Front clamping point connected - Solid - Finely stranded with end sleeve - Stranded - AWG cables, solid or stranded - Terminal screw mm² mm² m m² AWG 1 ... 10 1 ... 16 2.5 ... 25 14 ... 3 M4 • Rear clamping point connected - Solid - Finely stranded with end sleeve - Stranded - AWG cables, solid or stranded - Terminal screw mm² mm² m m² AWG 1 ... 10 1 ... 16 1.5 ... 25 14 ... 6 M4 - Front clamping point: Solid Finely stranded with end sleeve Stranded AWG cables, solid or stranded Terminal screw mm² mm² mm² AWG 1 ... 10 1 ... 101), 1 ... 61) 2.5 ... 10 14 ... 6 M4 - Rear clamping point: Solid Finely stranded with end sleeve Stranded AWG cables, solid or stranded Terminal screw mm² mm² mm² AWG 1 ... 10 1 ... 101), 1 ... 161) 2.5 ... 10 16 ... 3 M4 NSB0_00480 NSB0_00479 Conductor cross-sections • Both clamping points connected NSB0_00481 7 Terminal screw Operating devices Usable ring terminal lugs S00, S0 Screw terminals 1) The following can be connected when both clamping points are connected: - Front 1 ... 10 mm² and rear 1 ... 10 mm² - Front 1 ... 6 mm² and rear 1 ... 16 mm² 1/28 7/20 Product Category: IEC Siemens IC 10 · 2015 Siemens Industry, Inc. Industrial Controls Catalog SIRIUS 3RV Motor Starter Protectors • Revised • 10/25/15 General Data 3RV up to 100 A Overview S00 MSP with laterally mounted undervoltage release with leading auxiliary switch Functions Releases 3RV motor starter protectors are equipped with bimetallicbased, inverse-time delayed overload releases - electromagnetic short-circuit releases. The overload releases can be set in accordance with the load current. The overcurrent releases are permanently set to a value 13 times the rated current and thus enable trouble-free start-up of motors. The scale cover can be sealed to prevent unauthorized adjustments to the set current. Application Operating conditions 3RV MSP’s are suitable for use in any climate. They are designed for operation in closed rooms under normal conditions (e.g. no dust, corrosive vapours or harmful gases). Suitable enclosures must be provided for installation in dusty or damp rooms. 3RT1 SIRIUS MSP or Circuit Breaker • Size S00 - 3RV201 Maximum rated current is 16 Amps. Suitable for motors up to 10 hp at 600V. Available in both screw terminal and springtype terminal versions. Operating mechanisms S00, S0, S2 and S3 MSP's are actuated via a rotary operating mechanism. If the MSP trips, the rotary operating mechanism switches to the tripped position to indicate this. Before the MSP is reclosed, the rotary operating mechanism must be reset manually to 0 position, in order to prevent the former from closing by mistake before the fault has been cleared. • CLASS 10 A 2 s < tA < 10 s • CLASS 10 4 s < tA < 10 s • CLASS 20 6 s < tA < 20 s • CLASS 30 9 s < tA < 30 s The release must trip within this time! Motor Protection 3RV MSP’s use bimetallic heater elements to provide class 10 or 20 overcurrent protection for both AC and DC motors. The bimetallic heaters sense the motor current directly, so the overloads are insensitive to high frequencies, harmonic waves and sinusoidal currents and voltages. 1 1 Standard 0 = Motor Protection 7 = UL 489 4 = S3 - Each MSP has a fourth bimetallic strip that reacts only to the ambient temperature inside the control panel. This ambient compensation prevents the MSP from nuisance tripping when the panel temperature is higher than the ambient temperature of the motor. SIRIUS Innovations MSP or Circuit Breaker 3RV1 SIRIUS MSP or Circuit Breaker 1 1 Application 0 Frame Size Standard 0 = Motor Protection 1 = S00 7 = UL 489 2 = S0 0 0 1 1 Standard 0 = Motor Protection Frame Size 3 = S2 7 = UL 489 4 = S3 A A In the case of MSP’s with rotary operating mechanisms, an electrical signal can be output via a signalling switch to indicate that the MSP has tripped. All operating mechanisms can be locked in 0 position with a padlock (shackle diameter 3.5 to 4.5 mm). A built-in differential trip bar causes the MSP to trip faster on a phase loss condition, to help reduce motor damage from phase loss. Magnetic trip elements in each MSP take the device off line when it senses currents of 13 times the maximum FLA dial setting. 1 Class Terminal Type Possible choices listed below see page 1/4-1/7 for an entire listing A = 10 1 = Screw - 0 A A 1 Amperage Range Class Terminal Type Possible choices listed below see page 1/4-1/7 for an entire listing A = 10 1 = Screw - B through K 0 A A 2 = Spring Loaded 4 = Ring Lug 1 Amperage Range Class Terminal Type Possible choices listed below see page 1/4-1/7 for an entire listing A = 10 1 = Screw B = 20 2 = Spring Loaded 0, 1, 4 0 Auxiliary Switch 2 = Spring Loaded 4 = Ring Lug B through K 0, 1, 4 Application • Size S3 - 3RV104 Maximum rated current is 100 Amps. Suitable for motors up to 100 hp at 600V. Amperage Range 0, 1, 4 3RV2 • Size S2 - 3RV203 Maximum rated current is 50 Amps. Suitable for motors up to 50 hp at 600V. • Size S0 - 3RV202 Maximum rated current is 40 Amps. Suitable for motors up to 20 hp at 600V. Available in both screw terminal and springtype terminal verisons. Release classes The release classes of thermally delayed releases are based on the tripping time (tA) at 7.2 times the operational current in cold state (excerpt from IEC 60 9474): Frame Size 3 = S2 0 Application Construction The motor starter protectors are available in four sizes: 3RV Motor Starter Protectors (MSP’s) are built for a world of applications while meeting the requirements of control users worldwide. Each MSP features a manual ON/OFF switch, a Class 10 adjustable bimetallic overload relay (Class 20 available in the two largest frame sizes), and magnetic trip elements for short circuit protection. 0 Auxiliary Switch 0 Auxiliary Switch B through K Note: MPS’s and Contactors of the same frame size are made to easily fit together with the use of a link module. Siemens Industry, Inc. Industrial Controls Catalog Product Category: IEC 1/29 3RV Motor Starter Protectors • Revised • 10/25/15 General Data SIRIUS Mounting accessories Applications: The 3RV MSP’s can be used in a variety of applications: As a manual starter All 3RV MSP’s are UL listed as Manual Motor Controllers per UL508. This makes them ideal for applications requiring simple manual starting and stopping of motors. A separate short circuit protective device, such as a circuit breaker or fuses, is still required ahead of the MSP. This up-stream protective device should be sized per NEC code, not to exceed 400% of the maximum FLA adjustment dial setting. As a component in a group installation A group motor installation indicates multiple motor controllers under one short circuit protective device, such as a circuit breaker. 3RV MSP’s have a group installation short-circuit current rating of 65 kA at 480V and up to 30kA at 600V. By using a link module, a 3RT contactor can be directly mounted to the load side of the MSP. 3RV MSP’s have been UL tested with and without 3RT contactors for group installation. As a Self-protected manual combination starter, Type E. As part of a Combination Motor Contoller, Type F Most 3RV MSP’s have also been UL listed as UL508 Type E, Selfprotected Manual Combination Starters. This UL listing allows the MSP to be mounted in a manually operated machine without having to add separate short circuit protection upstream. When a 3RT contactor is connected to the load side of a 3RV device that is rated as a "Manual Self-protected Combination Motor Controller, Type E", the assembly can be applied as a "Combination Motor Controller, Type F". This versions allows for remote starting and stopping of the motor load. These devices have a short circuit current rating of 65 kA @ 240V, 480Y/277V and up to 30kA @ 600Y/347V. As a circuit breaker for export When exporting to many countries outside of the U.S. and North America, the 3RV can be applied as a thermal magnetic circuit breaker for use in motor branch circuits. 3RV29 28-1K 3RV29 38-1K These assemblies have a short circuit current rating of 65 kA @ 240V, 480Y/277V and up to 30 kA @ 600Y/347V. Terminals for "Combination Motor Controller Type E" to UL 508 The 3RV MSP for motor protection is approved according to UL 508 as "Combination Motor Controller Type E". As of July, 2001, UL 508 demands at line-side of the device used for this purpose an increased clearance and creepage distance (1" or 2"). Here, the terminal block 3RV29 28-1H must be used for size S0. The block is simply screwed to the basic unit. Basic units of size S2 are already compliant with new clearance and creepage distance requirements. Terminals for "Combination Motor Controller Type E" to UL 508 3RV29 28-1H The terminal block 3RT19 464GA07 must be used for size S3. The standard box terminal is to be replaced by this terminal block. 3RV29 28-1H According to CSA, these terminal blocks can be omitted when the device is used as "Combination Motor Controller Type E". By using a link module, a 3RT contactor can be directly mounted to the load side of a 3RV MSP. This assembly of a 3RV and a 3RT provides a complete, remotely operated, combination starter, Type F. 3RT19 46-4GA07 3RT19 46-4GA07 73.6 38.9 27.5 44.8 1/30 Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog 3RV Motor Starter Protectors SIRIUS General Data 3RV up to 100 A Switching of direct current 3RV motor starter protectors fo r alternating currents are also suitable for DC switching. The maximum permissible DC voltage per conducting path must, however, be adhered to. Higher voltages require a series connection with 2 or 3 conducting paths. The response values of the overload release remain unchanged; the response values of a short-circuit release increase by approximately 30 % for DC. The example circuits for DC switching can be seen in the table below. Example circuit for size S00 to S3 3RV motor starter protectors Example circuit for size S00 to S3 3RV motor starter protectors L+ L NSB0_00001a 150 V DC Three-pole switching, non-grounded system1) If there is no possibility of a ground fault, or if every ground fault is rectified immediately (ground-fault monitoring), then the maximum permitted DC voltage can be tripled. 300 V DC L L NSB0_00003a Two-pole switching, grounded system The grounded pole is always assigned to the individual conducting path, so that there are always 2 conducting paths in series in the event of a ground fault. M L+ 1) Notes M L+ NSB0_00002a Maximum permitted DC voltage Ue 450 V DC Single-pole switching, grounded system 3 conducting paths in series. The grounded pole is assigned to the unconnected conducting path. M It is assumed that this circuit always provides safe disconnection even in the event of a double ground fault that bridges two contacts. Design Mounting Screw connection The motor starter protectors are secured in position by snapping them onto 35 mm standard mounting rails according to DIN EN 50 022. A mounting rail with a height of 15 mm is required for S3 MSP’s. A 75-mm mounting rail can be used as an alternative here. 3RV MSP’s of sizes S00 and S0 are fitted with terminals with captive screws and clamping pieces, allowing the connection of 2 conductors with different cross-sections. S2 and S3 MSP’s can also be screwed directly onto a baseplate. The push-in lugs 3RV29 28-0B are available for screw mounting of S00 and S0 MSP’s. 3RV2928-0B The box terminals of the S2 and S3 MSP’s also enable 2 conductors with different crosssections to be connected. With the exception of S3 MSP’s which are equipped with 4 mm hexagon socket terminal screws, all terminal screws are tightened with a Pozidriv screwdriver size 2. The box terminals of the S3 MSP’s can be removed in order to connect conductors with cable lugs or connecting bars. A terminal cover is available to help prevent contact with shock protection and to ensure that the required clearances and creepage distances are maintained if the box terminals are removed. MSP with Spring-type terminal connection Spring-type connection 2) As an alternative to screw terminals, S00 and S0 devices are also available with Spring-type terminal connection. This screwless Spring-type terminal technique, as known for modular terminal blocks, offers shock-proof and vibration proof connection of conductors. Devices with Spring-type connection allow independent connection of two conductors per terminal. 1) It is assumed that this circuit always provides safe cut-out, even in the event of a double earth fault that bridges two contacts. 2) For notes on Spring-type terminal connection, see section 19. Siemens Industry, Inc. Industrial Controls Catalog Product Category: IEC 1/31 3RV Motor Starter Protectors General Data SIRIUS 3RV up to 100 A Characteristics The time/current characteristic, the current limiting characteristics and the I²t characteristics were determined in accordance with DIN VDE 0660 or IEC 60 947. The tripping characteristic of the inverse-time delayed overload releases (thermal overload releases or ’a’ releases) for DC and AC with a frequency of 0 to 400 Hz also apply to the time/current characteristic. The characteristics apply to the cold state. At operating temperature, the tripping times of the thermal releases are reduced to approximately 25 %. Under normal operating conditions, all three poles of the device must be loaded. The three main conducting paths must be connected in series in order to protect single-phase or DC loads. (short-circuit releases, ’n’ releases) are based on the rated current In that represents the maximum value of the setting range for MSP’s with adjustable overload releases. If the current is set to a lower value, the tripping current of the ’n’ release is increased by a corresponding factor. Typical time/current characteristic of 3RV The characteristics of the electromagnetic overcurrent releases apply to frequencies of 50/60 Hz. Appropriate correction factors must be used for lower frequencies up to 16 2/3 Hz, for higher frequencies up to 400 Hz and for DC. The printed characteristic curve determined for the MSP relates to a specific setting range. It is, however, also valid as a schematic representation of MSP’s with other current ranges. With 2-pole and 3-pole loading, the maximum deviation in the tripping time for 3 times the setting current and upwards is ± 20 % and thus in accordance with DIN VDE 0165. The tripping characteristics for the instantaneous, electromagnetic overcurrent releases Circuit diagrams Internal connections Motor starter protectors 3RV. 1/32 Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog 3RV Motor Starter Protectors • Revised • 10/25/15 SIRIUS General Data 3RV up to 100 A Dimension drawings 3RV2 MSP, size S00 3RV2 MSP, size S0 3RV20 11 3RV20 21 45 96.9 96.9 97 97 49 49 45 5 5 3RV2 MSP, size S2 149.4 144.4 55 3/ L2 5/ L3 2/ T1 4/ T2 6/ T3 30 4.8 130 5 140 70 1/ L1 12.4 3RV2.31 motor starter protector (<= 45A) 1) 2) 3) 4) 5) 6) 7) 8) 9) 10) 11) Siemens Industry, Inc. Industrial Controls Catalog Product Category: IEC 2-pole lateral auxiliary switch Signalling switch (S0-S3) or lateral auxiliary switch, 4-pole (S00-S3) Auxiliary releases Transverse auxiliary switch Push-in lugs for screw mounting Only for undervoltage release with leading auxiliary switch Drilling template 35 mm standard mounting rail acc. to EN 50 022 Mounting on 35 mm standard mounting rail, 15 mm high, acc. to EN 50 022 or on 75 mm standard mounting rail acc. to EN 50 023 4 mm hexagon socket screw Lockable in 0 position with shackle diameter 3.5 to 4.5 mm 1/33 3RV Motor Starter Protectors • Revised • 10/25/15 General Data 3RV up to 100 A SIRIUS 3RV2.32 MSP, size S2 149.3 144.3 55 3/ L2 5/ L3 2/ T1 4/ T2 6/ T3 30 4.8 130 5 140 70 1/ L1 12.4 3RV27 and 3RV28 circuit breakers, size S00, S0 and S3 3RV27 21, 3RV28 21 1) Mounting according to EN 60715 27 25 27 25 14 1414 14 45 45 106 144 106 144 NSB0_01726b 1) 1) NSB0_01726b 17 17 45 45 112 112 126 126 Ø5 2) Ø5 to standard rail TH 35. 1) Mounting according mounting to EN 60715 2) Drilling pattern. to standard mounting rail TH 35. 2) Drilling pattern. 2) 55 5579 79 92 92 3RV17 circuit breakers, size S3 3RV17 42 22,5 22,5 26 30 155 45 129 155 168 Ø5 1) Mounting according to EN 60715 on TH 35 standard mounting rail, 15 mm deep, or TH 75 standard mounting rail. 2) Drilling pattern. 2) NSB0_01531c 1) 70 1/34 5 7 132 153 157 169 Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog © Siemens AG 2015 SIRIUS 3RVMotor Motor Starter Protectors Starter Protectors/Circuit Breakers • Revised • 10/25/15 SIRIUS 3RV2 Motor Starter Protectors/Circuit Breakers up to Data 80 A General Accessories Mountable accessories Mountable accessories Overview Mounting location and function The 3RV2 motor starter protectors/circuit breakers have three main contact elements. In order to achieve maximum flexibility, auxiliary switches, signaling switches, auxiliary releases and isolator modules can be supplied separately. These components are easily fitted to the switches without the use of any tools according to requirements. Front side An auxiliary switch block can be inserted transversely on the front. The overall width of the motor starter protectors/circuit breakers remains unchanged. Note: • A maximum of four auxiliary contacts with auxiliary switches can be mounted on each motor starter protector/circuit breaker. Left-hand side Notes: • A maximum of four auxiliary contacts with auxiliary switches can be mounted on each motor starter protector/circuit breaker. • Lateral auxiliary switches (two contacts) and signaling switches can be mounted separately or together. • The signaling switch cannot be used for the 3RV27 and 3RV28 circuit breakers. Transverse auxiliary switches, solid-state compatible transverse auxiliary switches Overview graphic, see page 7/7. 1 NO + 1 NC or 2 NO or 1 CO Lateral auxiliary switches (2 contacts) 1 NO + 1 NC or 2 NO or 2 NC One of the three lateral auxiliary switches can be mounted on the left side per motor starter protector/circuit breaker. The contacts of the auxiliary switch close and open together with the main contacts of the motor starter protector/circuit breaker. The width of the lateral auxiliary switch with two contacts is 9 mm. Lateral auxiliary switches (4 contacts) 2 NO + 2 NC One lateral auxiliary switch with four contacts can be mounted on the left side per motor starter protector/circuit breaker. The contacts of the auxiliary switch close and open together with the main contacts of the motor starter protector/circuit breaker. Tripping 1 NO + 1 NC Short circuit 1 NO + 1 NC One signaling switch can be mounted on the left side of each motor starter protector. The signaling switch has two contact systems. One contact system always signals tripping irrespective of whether this was caused by a short circuit, an overload or an auxiliary release. The other contact system only switches in the event of a short circuit. There is no signaling as a result of switching off with the actuator. In order to be able to switch on the motor starter protector again after a short circuit, the signaling switch must be reset manually after the error cause has been eliminated. The overall width of the signaling switch is 18 mm. Right-hand side Auxiliary releases Notes: Shunt releases • One auxiliary release can be mounted per motor starter protector/circuit breaker. • Accessories cannot be mounted at the right-hand side of the 3RV21 motor starter protectors for motor protection with overload relay function. or For remote-controlled tripping of the motor starter protector/circuit breaker. The release coil should only be energized for short periods (see circuit diagrams). Undervoltage releases Trips the motor starter protector/circuit breaker when the voltage is interrupted and prevents the motor from being restarted accidentally when the voltage is restored. Used for remote-controlled tripping of the motor starter protector/circuit breaker. Particularly suitable for EMERGENCY-STOP disconnection by way of corresponding EMERGENCY-STOP pushbuttons according to DIN EN 60204-1. or Undervoltage releases with leading auxiliary contacts 2 NO Function and use as for the undervoltage release without leading auxiliary contacts, but with the following additional function: the auxiliary contacts will open in switch position OFF to deenergize the coil of the undervoltage release, thus interrupting energy consumption. In the "tripped" position, these auxiliary contacts are not guaranteed to open. The leading contacts permit the motor starter protector/circuit breaker to reclose. Isolator modules Isolator modules can be mounted to the upper connection side of the motor starter protectors. The overall width of the auxiliary release is 18 mm. Top Notes: • The isolator module cannot be used for the 3RV27 and 3RV28 circuit breakers. • The isolator module for size S2 - can only be used with 3RV2 motor starter protectors/circuit breakers up to max. 65 A - cannot be used with the transverse auxiliary switch • The isolator module covers the terminal screws of the transverse auxiliary switch. If the isolator module is used, we therefore recommend that either the lateral auxiliary switches be fitted or that the isolator module not be mounted until the auxiliary switch has been wired. Siemens Industry, Inc. Industrial Controls Catalog The supply cable is connected to the motor starter protector through the isolator module. The plug can only be unplugged when the motor starter protector is open and isolates all 3 poles of the motor starter protector from the network. The shock-protected isolation point is clearly visible and secured with a padlock to prevent reinsertion of the plug. For a complete overview of which accessories can be used for. the various motor starter protectors/circuit breakers, see page 7/2 1/35 Product Category: IEC Siemens IC 10 · 2015 7/31 7 The width of the lateral auxiliary switch with four contacts is 18 mm. Signaling switches 3RV Motor Starter Protectors General Data SIRIUS Mountable accessories Overview S00 and S0 motor starter protectors with mountable accessories 8 9 3 2 NSB0_02076 7 4 1 6.1 Motor starter protectors, sizes S2 or S3, with mountable accessories Mountable accessories for all sizes S00 ... S3 1 Transverse auxiliary switch 2 Lateral auxiliary switch with 2 contacts 3 Lateral auxiliary switch with 4 contacts 4 Shunt release 5 Undervoltage release 1/36 Mountable accessories for sizes 6.1 Undervoltage release with S00, S0 leading auxiliary contacts (can not be used with 3RV21 circuit breakers) S2, S3 6.2 Undervoltage release with leading auxiliary contacts Mountable accessories 7 Signaling switch (can not be used with 3RV27 and 3RV28 circuit breakers) 8 Isolator module (can not be used with 3RV27 and 3RV28 circuit breakers) for sizes S00 ... S3 S0 and S2 9 Terminal block E Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog 3RV Motor Starter Protectors SIRIUS General Data Mountable accessories Circuit diagrams Internal connections Shunt release 3RV19 02-1D / 3RV29 02-1D Undervoltage release 3RV19 02-1A / 3RV29 02-1A Transverse auxiliary switch 3RV19 01-1D 3RV29 01-1D 3RV19 01-1G 3RV29 01-1G 3RV19 01-1E 3RV29 01-1E 3RV19 01-2E 3RV29 01-2E 3RV19 01-1F 3RV29 01-1F Undervoltage release with leading auxiliary contacts 3RV19 22-1C / 3RV29 22-1C Lateral auxiliary switch with 2 contacts 3RV19 01-1B 3RV19 01-1A 3RV29 01-1B 3RV29 01-1A 3RV19 01-2B 3RV19 01-2A 3RV29 01-2B 3RV29 01-2A Lateral auxiliary switch with 4 contacts 3RV19 01-1J / 3RV29 01-1J SignalIng switch 3RV19 01-1C 3RV29 01-1C 3RV19 01-2C 3RV29 01-2C 3RV19 21-1M / 3RV29 21-1M S0; S1; S2 Q1 S OFF pushbuttons in system Motor starter protectors Auxiliary switch of MSP Q1 Fuses (gL/gG) max. 10 A Shunt release Undervoltage release External connections Shunt release Undervoltage release F1; F2 F3 F4 Siemens Industry, Inc. Industrial Controls Catalog Product Category: IEC 1/37 3RV Motor Starter Protectors • Revised • 10/25/15 General Data SIRIUS Mountable accessories Circuit diagrams Typical circuits 3RV2 MSP’s with 3RV29 21-1M signalling switch H1: "Short circuit" signal H2: "Overload" or "Tripped by auxiliary release" signal H1; H2 Indicator lights F1 Fuses (gL/gG) max. 10 A Q1 MSP S1 Signalling switch F1; F2 Fuses (gL/gG) max. 10 A Q1 MSP F4 Undervoltage release S1; S2, S3 OFF pushbuttons in system Separate "Tripped" and "Short circuit" signals Motor starter protectors tripped by means of pushbutton or EMERGENCY STOP button in the system The leading auxiliary contacts open in "OFF" position of the MSP to switch off the coil voltage of the undervoltage release, thus avoiding power consumption in switched off state. In the "tripped" position of the MSP, these contacts are not guaranteed to open. Dimension drawings Isolator modules 3RV29 28-1A for MSP’s size S00, S0 3RV29 38-1A for MSP’s size S2 144.7 107.9 56.9 54.8 For dimension drawings of auxiliary switches, signalling switches and auxiliary releases, see page 1/33 and 1/34. 1/38 Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog 3RV Motor Starter Protectors SIRIUS 3RV Motor Starter Protectors up to 100 A Accessories Busbar accessories Overview Busbar adapters The MSP’s are mounted directly with the aid of busbar adapters on fastbus-busbar systems with 40 mm and 60 mm centerline spacing, in order to save space and to reduce wiring times and costs. The MSP’s are snapped onto the adapter and connected on the line side. This prepared unit is then plugged directly onto the busbar system, and is thus connected both mechanically and electrically at the same time. Fastbus-busbar adapters for busbar systems with 40 mm centerline spacing are suitable for copper busbars with a width of 12 mm to 15 mm, while those with 60 mm centerline spacing are suitable for widths of 12 mm to 30 mm. The busbars can be 4 to 5 mm or 10 mm thick. Refer to page 1/10 for busbar adapters for specific MSP’s and accessories. SIRIUS MSP’s and combination starters with fastbus-busbar adapters snapped onto busbars Further busbar adapters for snap-mounting direct-on-line starters and reversing starters, as well as additional accessories such as line terminals and outgoing terminals, busbar copper, etc., can be found in Section 5. Insulated three-phase busbar system 8US busbar adapters for 60 mm systems Three-phase busbar systems provide an easy, time-saving and clearly arranged means of feeding 3RV2 motor starter protectors with screw terminals. They can be used for the different types of motor starter protector up to 32 A. The 3RV19 15 three-phase busbar systems are generally unsuitable for the 3RV21 motor starter protectors for motor protection with overload relay function and for the 3RV27 and 3RV28 circuit breakers according to UL 489 / CSA C22.2 No. 5-02. The motor starter protectors are mounted directly with the aid of busbar adapters on busbar systems with 60 mm center-to-center clearance in order to save space and to reduce infeed times and costs. The busbars are suitable for between 2 and 5 circuit breakers/motor starter protectors. However, any kind of extension is possible by clamping the tags of an additional busbar (rotated by 180°) underneath the terminals of the respective last motor starter protector. A combination of motor starter protectors of different sizes is possible. The motor starter protectors are supplied by appropriate feeder terminals. The busbar adapters for busbar systems with 60 mm center-tocenter clearance are suitable for copper busbars with a width of 12 mm to 30 mm. The busbars can be 5 mm or 10 mm thick. The motor starter protectors are snapped onto the adapter and connected on the line side. This prepared unit is then plugged directly onto the busbar system, and is thus connected both mechanically and electrically at the same time. For further busbar adapters for snap-mounting direct-on-line starters and reversing starters as well as additional accessories such as line terminals and outgoing terminals, flat copper profile, etc., can be found in Section 5. 3RV29 25-5AB 3RV19 15-1CB NSB0_02080 NSB0_02079 3RV29 15-5B 3RV19 15-6AB SIRIUS load feeders with busbar adapters snapped onto busbars SIRIUS three-phase busbar system size S00/S0 The three-phase busbar systems are finger-safe. They are designed for any short-circuit stress which can occur at the output side of connected motor starter protectors. Siemens Industry, Inc. Industrial Controls Catalog The three-phase busbar systems can also be used to construct “Type E Starters” according to UL/CSA. Special feeder terminals must be used for this purpose however (see “Selection and Ordering Data” on page 1/8). Product Category: IEC 1/39 3RV Motor Starter Protectors General Data • Revised • 10/25/15 SIRIUS Busbar accessories Dimension drawings 3RV19 15-1. . 3-phase busbar for S00 and S0 MSP’s, modular spacing 45 mm for 2 MSP’s 3RV19 15-1AB for 3 MSP’s 3RV19 15-1BB for 4 MSP’s 3RV19 15-1CB for 5 MSP’s 3RV19 15-1DB 3RV19 15-2. . 3-phase busbar for S00 and S0 circuit-breakers, modular spacing 55 mm for 2 MSP’s with accessories 3RV19 15-2AB for 3 MSP’s with accessories 3RV19 15-2BB for 4 MSP’s with accessories 3RV19 15-2CB for 5 MSP’s with accessories 3RV19 15-2DB 3RV19 15-3. . 3-phase busbar for S00 and S0 MSP’s, modular spacing 63 mm for 2 MSP’s with accessories 3RV19 15-3A for 3 MSP's with accessories 3RV19 15-3B for 4 MSP’s with accessories 3RV19 15-3C 3RV19 35-1. . 3-phase busbar for S2 MSP, modular spacing 55 mm for 2 MSP’s 3RV19 35-1A for 3 MSP’s 3RV19 35-1B for 4 MSP’s 3RV19 35-1C 98 33 15 110 168 55 1/40 Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog 3RV Motor Starter Protectors • Revised • 10/25/15 SIRIUS General Data Busbar accessories Dimension drawings 3RV19 35-3. . 3-phase busbar for S2 MSP, modular spacing 75 mm for 2 MSP’s with accessories 3RV19 35-3A for 3 MSP’s with accessories 3RV19 35-3B for 4 MSP’s with accessories 3RV19 35-3C 98 33 15 75 168 130 3RV29 25-5AB. 3-phase line-side terminals connection from above, size S00 and S0 3RV29 35-5B connection from above, size S00 and S0 a) 3RV1. 1 19 mm 3RV1. 2 23 mm 3RV29 25-5EB 3-phase line-side terminal connection from above, size S0 3RV19 35-5A 3-phase line-side terminal for MSP size S2 3RV19 15-5DB Connector For connecting a 3-phase busbar for MSP’s of the size S0 (left) to size S00 (right) 112 161 91 34 NSB00061b 55 3RV19 25-5EB to construct “Type E Starters” 3RV29 35-5E Connected from top, for motor starter protector size S0 Connected from top, for motor starter protector size S2 54.5 55,3 33,8 76.5 65.8 127,8 NSB0_02012 78,8 30,8 44 Siemens Industry, Inc. Industrial Controls Catalog Product Category: IEC 1/41 3RV Motor Starter Protectors General Data Motor Starter Protectors SIRIUS 3RV2 Motor Starter Protectors up SIRIUS to 40 A Accessories Rotary operating mechanisms Busbar accessories Overview Door-coupling rotary operating mechanisms NSB0_01079a Motor starter protectors with a rotary operating mechanism can be mounted in a control cabinet and operated externally by means of a door-coupling rotary operating mechanism. When the cabinet door with motor starter protector is closed, the operating mechanism is coupled. When the motor starter protector closes, the coupling is locked which prevents the door from being opened unintentionally. This interlock can be defeated by the maintenance personnel. In the OPEN position, the rotary operating mechanism can be secured against reclosing with up to 3 padlocks. Inadvertent opening of the door is not possible in this case either. 7 NSB0_01078 SIRIUS 3RV29 26-2B door-coupling rotary operating mechanism for arduous conditions SIRIUS 3RV29 26-0K door-coupling rotary operating mechanism Selection and ordering data Version Color of handle Version of exten- For motor sion shaft starter protectors mm DT Order No. Price per PU PU (UNIT, SET, M) PS* PG Size Door-coupling rotary operating mechanisms The door-coupling rotary operating mechanisms consist of a knob, a coupling driver and a 130/330 mm long extension shaft (6 mm x 6 mm). The door-coupling rotary operating mechanisms are designed to degree of protection IP64. The door locking device prevents accidental opening of the control cabinet door in the ON position of the motor starter protector. The OFF position can be locked with up to 3 padlocks. 3RV29 26-0B Door-coupling Black rotary operating mechanisms 130 330 S00, S0 S00, S0 } } 3RV29 26-0B 3RV29 26-0K 1 1 1 unit 1 unit 41E 41E EMERGENCY- Red/yellow 130 STOP 330 door-coupling rotary operating mechanisms S00, S0 S00, S0 } } 3RV29 26-0C 3RV29 26-0L 1 1 1 unit 1 unit 41E 41E Door-coupling rotary operating mechanisms for arduous conditions The door-coupling rotary operating mechanisms consist of a knob, a coupling driver, an extension shaft of 300 mm in length (8 mm x 8 mm), a spacer and two metal brackets, into which the motor starter protector is inserted. The door-coupling rotary operating mechanisms are designed to degree of protection IP65. The door interlocking reliably prevents opening of the control cabinet door in the ON position of the motor starter protector. The OFF position can be locked with up to 3 padlocks. Laterally mountable auxiliary releases and two-pole auxiliary switches can be used. The door-coupling rotary operating mechanisms thus meet the requirements for isolating functions according to IEC 60947-2. 3RV29 26-2B 1/42 Door-coupling Gray rotary operating mechanisms 300 S00, S0 } 3RV29 26-2B 1 1 unit 41E EMERGENCY- Red/yellow 300 STOP doorcoupling rotary operating mechanisms S00, S0 } 3RV29 26-2C 1 1 unit 41E * You can order this quantity or a multiple thereof. Illustrations are approximate Siemens Industry, Inc. Industrial Controls Catalog Product Category: IEC Siemens IC 10 · 2012 7/27 3RV Motor Starter Protectors SIRIUS General Data Rotary operating mechanisms Circuit diagrams Typical circuits 3RV1 MSP with 3RV19 36/3RV19 46 remote-controlled motorized operating mechanism US ~ - ~ + I 1 2 3 4 5 O M L v I T NSB00024a Dimensional drawings Door coupling rotary mechanism 3RV29 26-0B/3RV29 26-0C short shaft 4), for MSP sizes S00, S0, S2 and S3 45 66 25 19 15 1) Lockable in 0 position, with shackle diameter max. 8 mm 2) Mounting with screw cap 3) Supplied with a shaft length of 330 mm; adaptable by shortening of the shaft. 4) Supplied with a shaft length of 130 mm; adaptable by shortening of the shaft. 5) Grounding terminal 35 mm2 and bracket for 330 mm shaft. 1...4 1) 5 2) max 127 min 55 33 17 3 24.3 4) Ø2 NSB01108 2.5 max 130 min 56 3RV29 26-0K/3RV29 26-0L long shaft (with bracket) 3), for MSP sizes S00, S0, S2 and S3 16 45 66 25 15 19 1...4 I ON NSB01090a 0 OFF 1) 5 2) max 327 min 55 5) 33 17 3) Ø2 2.5 NSB01108 24.3 3 Siemens Industry, Inc. Industrial Controls Catalog max 330 min 56 Product Category: IEC 1/43 3RV Motor Starter Protectors General Data SIRIUS Rotary operating mechanisms Dimension drawings 3RV29 . 6-2. Door coupling rotary mechanism for heavy duty 3RV29 26-2., 3RV29 36-2., 3R29 46-2. for sizes S00, S0, S2 and S3 Drilling template, door G NSB01091a Drilling template, base J B A 75 65 6 40 6 D E F max. 341 min. 42 62 14 Type H Size 3RV29 26-2. S00, S0 3RV29 36-2. S2 3RV29 46-2. S3 min. 11 mm without shaft 1/44 C Dimensions A 125 170 194 B 111 144 180 C 50 60 60 D 77 87 100 E 112 162 187 F 50 50 48 G 27 27 25 H 9 10 10 I 42 47 53 max. 330 min. 31 Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog SIRIUS • Revised • 10/25/15 3RV Motor Starter Motor StarterProtectors Protectors Data SIRIUS 3RV1 Motor Starter ProtectorsGeneral up to 100 A Accessories Accessories Enclosures and frontplates plates Enclosures and front Overview Enclosure Front plates For stand-alone installation of motor starter protector size S2 (In max = 65 A), molded-plastic enclosures for surface mounting are available. Motor starter protectors are frequently required to be actuated in any enclosure. Front plates equipped with a rotary operating mechanism for motor starter protector sizes S2 and S3 are available for this purpose. When installed in a molded-plastic enclosures the motor starter protectors have a rated operational voltage Ue of 500 V. NSB0_02193 NSB0_02194 The molded-plastic enclosures are designed to degree of protection IP55. 7 Front plate for size S2 Enclosures for surface mounting All enclosures are equipped with N and PE terminals. There are two knock-out cable entries for cable glands at the top and two at the bottom; also on the rear corresponding cable entries are scored. There is a knockout on the top of the enclosure for indicator lights that are available as accessories. In the enclosure for motor starter protector size S2 there is also room for the laterally mounted auxiliary release. There is no provision for installing a motor starter protector with a signaling switch. The molded-plastic enclosures of the size S2 motor starter protectors are fitted with a rotary operating mechanism. The enclosures can be supplied with either a black rotary operating mechanism or with an EMERGENCY-STOP rotary operating mechanism with a red/yellow knob. The rotary operating mechanisms can be locked in the Open position with up to 3 padlocks. Siemens Industry, Inc. Industrial Controls Catalog 1/45 Product Category: IEC Siemens IC 10 · 2012 7/61 3RV Motor Starter Protectors General Data • Revised • 10/25/15 SIRIUS Mounting accessories Dimension drawings 3RV19 . 3-1. . . . Cast aluminum enclosure for wall mounting for MSP’s of size S2 3RV19 33-1. . . . 1) 2) 3) 4) Knock-outs for M32 (left) and M40 (right). M32 knock-outs for rear-side cable entry. Opening for padlock with shackle diameter max. 8 mm. Indicator light 3RV19 03-5. Molded-plastic front plate 3RV19 23-4. for MSP sizes S0, S2, S3 3RV29 23-4B 3RV29 23-4E 3RV19 23-4G (only for size S0) 1/46 Product Category: IEC Siemens Industry, Inc. Industrial Controls Catalog 3RV Motor Starter Protectors SIRIUS General Data 3RV Spring-type terminal infeed system Design Installation guidelines Distance in Y direction from live, earthed or insulated parts according to IEC 60947-4: 10 mm. In addition, the installation guidelines for motor starter protectors or fuseless load feeders including the clearances must be complied with. Technical specifications 3RV29 .7 Type Rated operational voltage Ue • IEC - 10 % overvoltage - 5 % overvoltage V V 500 525 • UL/CSA V 600 Rated frequency Hz 50/60 Rated current In A 63 • During storage/transport • During operation °C °C -50 ... +80 -20 ... +60 Permissible rated current of the 3RV10 11 motor starter protectors (size S00) at control cabinet internal temperature • +60 °C % 100 • +60 °C % 100 % % 100 87 Permissible ambient temperature Permissible rated current of the 3RV10 21 motor starter protectors (size S0) up to 16 A at control cabinet internal temperature Permissible rated current for 3RV1. 21 motor starter protectors (size S0) from 16 A at control cabinet internal temperature • +40 °C • +60 °C IP201) Degree of protection acc. to IEC 60529 Touch protection acc. to IEC 61140 Conductor cross-sections for main circuit infeed • • • • Solid, stranded: Finely stranded with end sleeve Finely stranded without end sleeve AWG cables, solid or stranded Conductor cross-sections of terminal block • • • • 1) Solid Finely stranded with end sleeve Finely stranded without end sleeve AWG cables, solid or stranded Finger-safe mm2 mm2 mm2 AWG 4 ... 25 4 ... 25 6 ... 25 10 ... 3 mm2 mm2 mm2 AWG 1.5 ... 6 1.5 ... 4 1.5 ... 6 15 ... 10 In infeed terminal compartment without a conductor connected: IP00. Siemens Industry, Inc. Industrial Controls Catalog Product Category: IEC 1/47 3RV Motor Starter Protectors General Data SIRIUS 3RV Cage clamp infeed system Cage Clamp infeed system 3-phase busbars with line-side terminals for 2 circuit-breakers of sizes S00 and S0 3RV29 17-1. 75 a 108 4,5 NSB0_01248 278 45 128 128 80 70 108 15 75 7,5 a S00 S0 104 125 S00 S0 3-phase busbars for system expansion for 2 and 3 circuit-breakers of sizes S00 and S0 3RV29 17-4. 90 75 a 4,5 NSB0_01249 128 278 45 128 128 70 80 135 120 15 75 7,5 a 1/48 Product Category: IEC 104 125 Siemens Industry, Inc. Industrial Controls Catalog