FCI FBR2545CTL

25 Amp SCHOTTKY
BARRIER RECTIFIERS
FBR2535CTL & 2545CTL
Data Sheet
Mechanical Dimensions
Description
JEDEC
T0-220AB
.10
.14
.39 .42
.100
.50
.225 Min
.25
.620
Features
n HIGH CURRENT CAPABILITY
WITH LOW VF
n HIGH SURGE VOLTAGE AND
TRANSIENT PROTECTION
n HIGH EFFICIENCY w/LOW POWER LOSS
n MEETS UL SPECIFICATION 94V-0
Electrical Characteristics @ 25o C.
FBR2535CTL
35
35
35
Maximum Ratings
Peak Repetitive Reverse Voltage...VRRM
Working Peak Reverse Voltage...VRWM
DC Blocking Voltage...VDC
Pulse Test 0.5 mS, Duty Cycle 1/140
Units
FBR2535CTL & 2545CTL
FBR2545CTL
45
45
45
Volts
Volts
Volts
............................................. 12.5 ...............................................
Amps
............................................. 2 5 ...............................................
Amps
Non-Repetitive Peak Forward Surge Current...IFSM
@ Rated Load Conditions, ½ Sine Wave, Single Phase, 60HZ
............................................. 150 ...............................................
Amps
Repetitive Peak Reverse Surge Current...IRSM
@ 2uS PW, F = 1.0 KHZ
............................................. 1.0 ...............................................
Amps
< ................. 0.55 .................. > < ................. 0.6 .................. >
< ................. 0.47 .................. > < ................. 0.52 .................. >
< ................. 0.41 .................. > < ................. 0.46 .................. >
Volts
Volts
Volts
Average Forward Rectified Current...IF(av)
TC = 110°C (Rated VR)
Repetitive Peak Forward Surge Current...IFM
TC = 95°C (Rated VR, Square Wave, 20KHZ)
Per Leg
Forward Voltage...VF
Per Leg, 300uS, 2% Duty Cycle @ IF = 25 Amps, 25°C
Per Leg, 300uS, 2% Duty Cycle @ IF = 12.5 Amps, 25°C
Per Leg, 300uS, 2% Duty Cycle @ IF = 12.5 Amps, 125°C
DC Reverse Current (@ VR = VRM)...IR
@ Rated DC Blocking Voltage
Thermal Resistance, Junction to Case...RθJC
TC = 25°C
TC = 125°C
TC = 100°C
............................................. 5.0 ............................................... mAmps
< ................. 500 .................. >
mAmps
< ................. 500 .................. > mAmps
............................................. 2.0 ............................................... °C / W
Voltage Rate of Change (Rated VR)
............................................. 1000 ............................................... V / µS
Controlled Avalanche Energy...WAVAL
............................................. 2 0 ...............................................
mJ
Operating Temperature Range...TJ
......................................... -65 to 125 ..........................................
°C
Storage Temperature Range...TSTRG
......................................... -65 to 150 ..........................................
°C
Page 7-34
25 Amp SCHOTTKY
BARRIER RECTIFIERS
Typical Reverse Current
Current Derating, Per Leg
Amps
Reverse Current (mA)
TJ = 125oC
TJ = 100oC
TJ = 75oC
Reverse Voltage (Volts)
Ambient Temperature (oC)
Forward Characteristics
Amps
Forward Current (Amps)
Current Derating
FBR2535CTL & 2545CTL
Data Sheet
Case Temperature (oC)
Forward Voltage (Volts)
Average Forward Power (Watts)
Forward Power Dissipation
Common Cathode,
Suffix "C"
1
3
Average Forward Current (Amps)
NOTES: 1. Measured @ 1 MHZ and applied reverse voltage of 4.0V.
2. Thermal Resistance Junction to Case, Jedec Method.
3. When Mounted to heat sink, from body.
2
Case
Ratings at
25 Deg. C ambient
temperature
unless otherwise
specified.
Single Phase Half
Wave, 60 HZ
Resistive or
Inductive Load.
For Capacitive
Load, Derate
Current by 20%.
Page 7-35