© Siemens AG 2014 SIMOTICS FD Flexible Duty Motors Motors Catalog D 81.8 Edition 04/2014 Answers for industry. © Siemens AG 2014 Related catalogs SIMOTICS Low-Voltage Motors Type series 1LE1, 1MB1 and 1PC1 Frame sizes 80 to 315 Power range 0.3 to 250 kW D 81.1 www.siemens.com/motors/printmaterial The listed documentation can be ordered here or it is available in commonly used file formats (PDF, ZIP) for downloading. E86060-K5581-A111-A6-7600 Energy saving/Energy-saving program SinaSave SINAMICS Drives SINAMICS G130 Drive Converter Chassis Units SINAMICS G150 Drive Converter Cabinet Units E86060-K5511-A101-A5-7600 D 11 SINAMICS S120 Chassis Format Units and Cabinet Modules SINAMICS S150 Converter Cabinet Units E86060-K5521-A131-A3-7600 D 21.3 FLENDER couplings Standard Couplings Interactive Catalog CA 01 – Selection tool DT Configurator The selection tool DT Configurator is available in conjunction with the electronic catalog CA 01 on DVD. MD 10.1 In addition, the DT Configurator can be used on the Internet without requiring any installation. The DT Configurator can be found in the Siemens Mall under the following address: www.siemens.com/dt-configurator D 87.1 E86060-K5287-A111-A4-7600 Industrial Communication SIMATIC NET IK PI E86060-K6710-A101-B7-7600 AC NEMA & IEC Motors D 81.2 Further details available on the Internet U.S./ at: Canada Only PDF www.sea.siemens.com/motors Products for Automation and Drives Interactive Catalog, DVD E86060-D4001-A510-D3-7600 Industry Mall Information and Ordering Platform in the Internet: www.siemens.com/industrymall Further information on the subject of energy saving and the energysaving program SinaSave is available at the following address: www.siemens.com/energysaving E86060-K5710-A111-A4-7600 MOTOX Geared Motors All information material, such as brochures, catalogs, manuals and operating instructions for standard drive systems are available up-to-date on the Internet at the following address: The DT Configurator for motors, mechanical components, converters, connection systems, control and licenses and system configuration can be found in the CA 01 main menu, under drive systems, selection and engineering tools. • 2D/3D model generator for motors and converters • Data sheet generator • Start-up calculation • Comprehensive product-specific documentation Hardware and software requirements • PC with 1.5 GHz CPU or faster • Operating systems – Windows XP – Windows NT 4.0 (SP6 and higher) – Windows Vista – Windows 7 • At least 1 GB RAM (2 GB recommended) • Screen resolution 1024 × 768, graphics with more than 256 colors, small fonts • DVD drive for offline version (CA 01) • Windows-compatible sound card • Windows-compatible mouse Installation CA 01 The CA 01 Catalog can be directly installed on the hard disk or in the network from the DVD as a partial or full version. © Siemens AG 2014 Motors SIMOTICS FD Flexible Duty Motors Catalog D 81.8 · 04/2014 The products and systems described in this catalog are manufactured/distributed under application of a certified quality management system in accordance with DIN EN ISO 9001 (Certified Registration No. DE-000357 QM). The certificate is recognized by all IQNet countries. Please contact your local Siemens branch Introduction 1 Technical Information 2 System Components 3 Self-ventilated motors – enclosed version 4 Forced-air cooled motors – enclosed version 5 Water-cooled motors with water-jacket cooling 6 Water-cooled motors with air-to-water heat exchanger 7 Self-ventilated motors – open version 8 Forced-air cooled motors – open version 9 © Siemens AG 2014 Printed on paper from sustainably managed forests and controlled sources. www.pefc.org Explosion-proof motors Technical Information 10 Article No. supplements and special versions 11 Application-specific motors 12 Appendix 13 © Siemens AG 2014 2 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Answers for industry. Integrated technologies, vertical market expertise and services for greater productivity, energy efficiency, and flexibility. The Siemens Industry Sector is the world's leading supplier of innovative and environmentally friendly products and solutions for industrial companies. End-to-end automation technology and industrial software, solid market expertise, and technology-based services are the levers we use to increase our customers’ productivity, efficiency and flexibility. With a global workforce of more than 100 000 employees, the Industry Sector comprises the Industry Automation, Drive Technologies, and Customer Services divisions, as well as the Metals Technologies Business Unit. We consistently rely on integrated technologies and, thanks to our bundled portfolio, we can respond more quickly and flexibly to our customers' wishes. With our globally unmatched range of automation technology, industrial control and drive technology as well as industrial software, we equip companies with exactly what they need over their entire value chain – from product design and development to production, sales and service. Our industrial customers benefit from our comprehensive portfolio, which is tailored to their market and their needs. Market launch times can be reduced by up to 50 % due to the combination of powerful automation technology and intelligent industrial software from Siemens Industry. At the same time, the costs for energy or waste water for a manufacturing company can be reduced significantly. In this way, we increase our customers’ competitive strength and make an important contribution to environmental protection with our energy-efficient products and solutions. Siemens D 81.8 · 04/2014 3 © Siemens AG 2014 (53²(QWHUSULVH5HVRXUFH3ODQQLQJ 3/0²3URGXFW/LIHF\FOH0DQDJHPHQW 0DQDJHPHQW/HYHO 3URGXFW'HVLJQ 3URGXFWLRQ3ODQQLQJDQG6LPXODWLRQ 'DWD0DQDJHPHQW 0(6²0DQXIDFWXULQJ([HFXWLRQ6\VWHPV 6,0$7,&,7 2SHUDWLRQV/HYHO 0DLQWHQDQFH $VVHW0DQDJHPHQW 6,0$7,&3&6 2SHUDWRU6\VWHP (QHUJ\ 0DQDJHPHQW (QJLQHHULQJ 6WDWLRQ 7,$3RUWDO &RQWURO/HYHO 6,0$7,&3&6 $XWRPDWLRQ 6\VWHPV 6,180(5,. &RPSXWHU1XPHULF&RQWURO 6,027,21 0RWLRQ&RQWURO 6,0$7,&1(7 ,QGXVWULDO &RPPXQLFDWLRQ 6,0$7,&&RQWUROOHUV 0RGXODU3&EDVHG )LHOG/HYHO 352),%863$ 3URFHVV,QVWUXPHQWDWLRQ 7RWDOO\ ,QWHJUDWHG $XWRPDWLRQ 6,0$7,&'LVWULEXWHG,2 6,0$7,&,GHQW ,QGXVWULDO,GHQWLÀFDWLRQ +$57 ,2/LQN Setting standards in productivity and competitiveness. Totally Integrated Automation. 4 Siemens D 81.8 · 04/2014 © Siemens AG 2014 TIA is characterized by its unique continuity. It provides maximum transparency at all levels with reduced interfacing requirements – covering the field level, production control level, up to the corporate management level. With TIA you also profit throughout the complete life cycle of your plant – starting with the initial planning steps through operation up to modernization, where we offer a high measure of investment security resulting from continuity in the further development of our products and from reducing the number of interfaces to a minimum. 3ODQW(QJLQHHULQJ &2026 (WKHUQHW 6,0$7,&:LQ&& 6&$'$6\VWHP The unique continuity is already a defined characteristic at the development stage of our products and systems. ,QGXVWULDO(WKHUQHW 6,0$7,&+0, +XPDQ0DFKLQH,QWHUIDFH The result: maximum interoperability – covering the controller, HMI, drives, up to the process control system. This reduces the complexity of the automation solution in your plant. You will experience this, for example, in the engineering phase of the automation solution in the form of reduced time requirements and cost, or during operation using the continuous diagnostics facilities of Totally Integrated Automation for increasing the availability of your plant. 6,5,86,QGXVWULDO&RQWUROV 352),1(7 ,QGXVWULDO(WKHUQHW 352),%86 6,1$0,&6'ULYH6\VWHPV 6,7233RZHU6XSSO\ $6,QWHUIDFH .1;*$00$LQVWDEXV /RZ9ROWDJH'LVWULEXWLRQ 7RWDOO\ ,QWHJUDWHG 3RZHU 6,027,&60RWRUV Thanks to Totally Integrated Automation, Siemens provides an integrated basis for the implementation of customized automation solutions – in all industries from inbound to outbound. Siemens D 81.8 · 04/2014 5 © Siemens AG 2014 Totally Integrated Power: Future-proof power supply from one source. 6 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Software tools, products, systems and support for integrated electrical power distribution Energy Management/ Energy Transparency Operation & Monitoring Load management Load curves Forecast Maintenance Substation Distribution Maintenance task Status reporting/ failure management Protocols Power Quality DATE: Cost center EMPLOYEE COST CENTER PAY PERIOD BEGINNING PAY PERIOD ENDING DATE SUN MON TUE WED THUR FRI SUN MON TUE WED THUR FRI SAT SUN TOTAL IN OUT IN OUT OVERTIME TOTAL HOURS DATE SAT SUN TOTAL IN OUT U I cos o P W IN Hall 1 Distribution 3 Process/ industrial automation Products & Systems Infeed II Renewables Medium voltage with protection technology Air conditioning system checkup Replacing circuit breaker contacts Replacing meters OUT OVERTIME TOTAL HOURS central ON OFF local ON OFF tripped Transformer DATE SUN MON TUE WED THUR FRI SAT SUN TOTAL IN OUT IN OUT Building automation OVERTIME TOTAL HOURS Low voltage with protection and measuring technology ≤ 110 kV Planning Software Tools The power supply system acts like a “vital artery”, forming the basis for the reliable and efficient functioning of all electrically operated building installations. Electrical power distribution therefore requires integrated solutions. Our answer: Totally Integrated Power (TIP). This includes software tools and support for planning and configuration and a complete, optimally aligned product and system portfolio for integrated power distribution from medium-voltage switchgear right to socket outlets. Network dimensioning with SIMARIS design Space requirements and budget calculation with SIMARIS project The power distribution products and systems can be interfaced to building or industrial automation systems (Total Building Solutions or Totally Integrated Automation) via communication-capable circuit breakers and components, allowing the full potential for optimization that an integrated solution offers to be exploited throughout the project cycle – from planning right through to installation and operation. Visualization of device characteristics with SIMARIS curves Get more information: www.siemens.com/tip www.siemens.com/simaris www.siemens.com/specifications Siemens D 81.8 · 04/2014 7 © Siemens AG 2014 Integrated Drive Systems Faster on the market and in the black with Integrated Drive Systems SIMOTICS FD is an important element of a Siemens Integrated Drive System, contributing significantly to increased efficiency, productivity, and availability in industrial production processes. Horizontal, vertical, and lifecycle integration ensure that every drive system component fits seamlessly into the whole system, into any automation environment, and even into the entire lifecycle of a plant. Integrated Drive Systems are Siemens’ trendsetting answer to the high degree of complexity that characterizes drive and automation technology today. The world’s only true one-stop solution for entire drive systems is characterized in particular by its threefold integration: The outcome is an optimal workflow – from engineering all the way to service that entails more productivity, increased efficiency, and better availability. That’s how Integrated Drive Systems reduce time to market and time to profit. Horizontal integration Integrated drive portfolio: The core elements of a fully integrated drive portfolio are frequency converters, motors, couplings, and gear units. At Siemens, they‘re all available from a single source. Perfectly integrated, perfectly interacting. For all power and performance classes. As standard solutions or fully customized. No other player in the market can offer a comparable portfolio. Moreover, all Siemens drive components are per fectly matched, so they are optimally interacting. You can boost the availability of your application or plant to up to 99% * *e.g., conveyor application Vertical integration Thanks to vertical integration, the complete drive train is seamlessly integrated in the entire automation environment – an important prerequisite for production with maximum value added. Integrated Drive Systems are part of Totally Integrated Automation (TIA), which means that they are perfectly embedded into the system architecture of the entire industrial production process. This enables optimal processes through maximum communication and control. With TIA Portal you can cut your engineering time by up to 30% Lifecycle integration Lifecycle integration adds the factor of time: Software and service are available for the entire lifecycle of an Integrated Drive System. That way, important optimization potential for maximum productivity, increased efficiency, and highest availability can be leveraged throughout the system’s lifecycle – from planning, design, and engineering to operation, maintenance, and all the way even to modernization. With Integrated Drive Systems, assets become important success factors. They ensure shorter time to market, maximum productivity and efficiency in operation, and shorter time to profit. With Integrated Drive Systems you can reduce your maintenance costs by up to 15% www.siemens.com/ids 8 Siemens D 81.8 · 04/2014 1 © Siemens AG 2014 Introduction 1/2 1/2 1/2 1/3 1/3 1/4 1/4 1/5 1/6 1/6 1/6 Orientation Overview The SIMOTICS family of motors Performance features of the SIMOTICS FD series Overview of product lines Benefits Application Technical specifications Article number code Overview Structure of the article numbers for SIMOTICS FD motors Siemens D 81.8 · 04/2014 © Siemens AG 2014 Introduction Orientation ■ Overview The SIMOTICS family of motors With SIMOTICS, Siemens offers a comprehensive portfolio of electric motors. From energy-efficient, low-voltage motors through servomotors with high dynamic performance up to wellproven DC motors and powerful high-voltage motors. Innovative drive technology for all industries, applications and performance classes. Outstanding performance, quality, efficiency and compactness. SIMOTICS Low-voltage motors for mains-fed and converter-fed operation General Purpose SIMOTICS GP Severe Duty SIMOTICS SD Explosion-proof SIMOTICS XP Definite Purpose SIMOTICS DP Flexible Duty SIMOTICS FD DC Motors High Voltage Motors Direct Current SIMOTICS DC High Voltage SIMOTICS HV Transnorm SIMOTICS TN High Torque SIMOTICS HT Motors for Motion Control SIMOTICS S Servomotors SIMOTICS M Main Motors SIMOTICS L Linear Motors SIMOTICS T Torque Motors G_D081_EN_00428 1 SIMOTICS – Low-voltage motors for mains-fed and converter-fed operation SIMOTICS low-voltage motors for mains-fed and converter-fed operation are subdivided into seven segments depending on the particular application. • General Purpose – SIMOTICS GP Motors for everyday applications in industry under standard environmental conditions. • Severe Duty – SIMOTICS SD Motors with cast-iron housing for applications under harsh environmental conditions. • Explosion Protected – SIMOTICS XP Motors for potentially explosive atmospheres. • Definite Purpose – SIMOTICS DP Special motors, e.g. smoke extraction motors or built-in motors. 1/2 Siemens D 81.8 · 04/2014 • Flexible Duty – SIMOTICS FD Converter-optimized motor series for flexible applications with higher outputs in the range of 200 kW to over 1600 kW, with various cooling methods. Water-cooled motors are also offered for mains-fed operation. • Transnorm – SIMOTICS TN Motors with cast-iron housing with higher outputs in the range of 145 kW to 1250 kW. • High Torque – SIMOTICS HT Permanent magnet synchronous motors for applications that require extremely powerful drives without gear unit, even at low speeds. © Siemens AG 2014 Introduction Orientation 1 ■ Overview (continued) Performance features of the SIMOTICS FD series The SIMOTICS FD series is characterized by the following features: • Series of low-voltage motors optimized for converter-fed operation • Three product lines - Air-cooled, enclosed version - Water-cooled version - Air-cooled, open version • Wide output range from 125 kW to over 895 kW in frame sizes 315 and 355 • Rugged cast-iron housing A wide range of water-cooled motors is also available for mains-fed operation. The SIMOTICS FD motor series covers outputs from 200 kW and higher (at 1500 rpm), and is available in a version optimized for converter-fed operation with various cooling methods and as a water-cooled version for mains-fed operation. This motor series has an extremely long service life, is rugged and ensures the highest availability thanks to various technical details. For instance, KTY 84-130 temperature sensors are integrated as standard in the winding as motor protection. SIMOTICS FD motors are characterized by a very high output with a small frame size. The result of this is an extremely compact design that saves space in a number of industrial applications. SIMOTICS FD motors are not only optimized in terms of their design, but also in terms of their efficiency, so they also contribute towards lower energy consumption. The version optimized for converter-fed operation as part of a drive system is harmonized for operation with SINAMICS lowvoltage frequency converters. Together with SINAMICS, it forms an optimally harmonized drive system for variable-speed applications. Overview of product lines Air-cooled, enclosed version Water-cooled version Air-cooled, open version with self-ventilation with forced-air cooling with with water-jacket cooling heat exchanger with self-ventilation with forced-air cooling Operation VSD VSD DOL & VSD VSD VSD VSD Output 200 ... 590 kW 200 ... 595 kW 200 ... 735 kW 200 ... 840 kW 200 ... 850 kW 200 ... 895 kW Cooling method IC411 IC416 1) IC71W IC86W IC01 IC06 1) Degree of protection 2) IP55 IP55 IP55 IP55 IP23 IP23 Features Basic design Low-noise or increased output High power density, High power density, Basic design potable/fresh water seawater cooling cooling Primary load M ~ n2 characteristic *) T = const T = const M ~ n2 T = const M ~ n2 M ~ n2 T = const Motor type Safe Area 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 Motor type Ex n, Ex t 3) 1MM1 1MQ1 1MH1 1MN1 – – Low-noise or increased output VSD Variable Speed Drives (converter-fed operation) DOL Direct On Line (mains-fed operation) 1) 2) Cooling method IC37 (separately cooled using an external pipe system) on request. 3) Explosion-proof motors, Zones 2 and 22. *) M = Torque Other degrees of protection optionally available. Siemens D 81.8 · 04/2014 1/3 © Siemens AG 2014 Introduction Orientation 1 ■ Benefits The SIMOTICS FD motor series has been specifically developed for operation with SINAMICS converters. To supplement our portfolio in the low-voltage motor range, a water-cooled version for mains-fed operation has been created. 7 The optimized efficiency results in lower operating costs. 7 The high power density and compact design ensure low space requirements combined with low weight. 7 A highly harmonized drive system is created as the motor is optimally matched to the converter. For instance, it has optimized noise levels, the converter does not have to be derated and the temperature rise is low. 7 The cast-iron housing and bearing plates are extremely rigid and rugged and can therefore be subjected to considerable stress. They have excellent vibration damping properties and are resistant to corrosion. 7 The bearings are designed for maximum reliability, which results in good vibration characteristics, a long service life and low maintenance costs. 7 The DURIGNIT IR 2000 insulation system with VPI or current UV impregnation results in high reliability, a long service life and high resistance to stress, for example, during starting or under overload conditions. 7 Due to the low noise emission level, the stringent requirements of occupational safety are fulfilled without the need for any additional measures. Greater output With SIMOTICS FD, we have increased the power density so that we offer higher outputs for the same frame size. Optimized tuning for converter-fed operation The new motor series has been optimized for operation on SINAMICS G120P, G130, G150, S120, S120CM and S150 converters with regard to converter output currents and voltage utilization. Through the use of optimized pulse patterns and the new nonribbed housing, the SIMOTICS FD and frequency converter system is noise optimized. More flexibility As a result of the new motor design, SIMOTICS FD motors fulfill the most exacting customer requirements in terms of variance and mounted options. For instance, the optimized motor design allows terminal boxes, separately driven fans and mounted coolers to be flexibly mounted as required and monitoring devices can be added easily. Improved design The optimized housing in a modern design has an attractive appearance and enhances functionality with the flexible, modular system. For instance, this is ensured by the optimized, easy to access terminal box that has been newly developed, with flexible terminal box position. A wider range of applications The motors are available in country and industry-specific versions, complying with the relevant regulations, standards and directives. ■ Application With their numerous options, the SIMOTICS FD motor series can be used in all areas of industry. Paper, steel, energy, marine, chemical, water/wastewater are some examples here. The available types of construction are IM B3, IM B35 and IM V1 according to EN 60034-7. IP55/IP54 is the standard degree of protection (IP23 for open-circuit ventilation). 1/4 Siemens D 81.8 · 04/2014 The wide field of applications that can be addressed includes, for example, the following: • Pumps • Fans • Compressors • Cranes • Propeller drives, bow thrusters • Paper machines • Winches • Centrifuges • Handling lines • Conveyor belts • Rolling mills • Extruders © Siemens AG 2014 Introduction Orientation 1 ■ Technical specifications General technical specifications Type of motor SIMOTICS FD IEC low-voltage motors Frame sizes 315, 355 Rated output 125 … 895 kW Rated speed 750 ... 3600 rpm Rated torque 610 … 4586 Nm Versions Air-cooled, enclosed version • with self-ventilation • with forced-air cooling Water-cooled version • with water-jacket cooling • with heat exchanger Air-cooled, open version • with self-ventilation • with forced-air cooling Efficiency marking For motors in mains-fed operation only Efficiency class in accordance with IEC 60034-30: IE2, IE3 (4- and 6-pole) Insulation of the stator winding according to EN 60034-1 (IEC 60034-1) Temperature class 180 (H) DURIGNIT IR 2000 insulation system Degree of protection according to EN 60034-5 (IEC 60034-5) As standard IP55/IP54 Air-cooled, enclosed version; water-cooled version IP23 Air-cooled, open version Cooling according to EN 60034-6 (IEC 60034-6) • Self-ventilated 1LM1 motors (IC411) • Forced-air cooled 1LQ1 motors (IC416) • Water-cooled 1LH1 motors (IC71W) • Air-water heat exchanger – 1LN1 motors (IC86W) • Self-ventilated, open-circuit ventilated 1LL1 motors (IC01) • Forced-air cooled, open-circuit ventilated 1LP1 motors (IC06) Admissible coolant temperature and site altitude As standard -20 ... +40 °C, site altitude up to 1000 m above sea level. Standard voltages according to EN 60038 (IEC 60038) VSD: 50 Hz systems: 400 V, 500 V, 690 V 60 Hz systems: 460 V and 575 V DOL: 50 Hz systems: 400 V and 690 V 60 Hz systems: 460 V The voltage to be used can be found in the "Selection and ordering data" for the required motor. Type of construction according to EN 60034-7 (IEC 60034-7) • Without flange: IM B3 • With flange: IM B35, IM V1 Paint finish Suitability of paint finish for climate group according to IEC 60721, Part 2-1 Standard: color RAL 7030 stone gray Vibration quantity level according to EN 60034-14 (IEC 60034-14) Level A (normal) Optionally: level B (with special vibration requirements) Shaft extension according to DIN 748 (IEC 60072) Balance type: half-key balancing as standard Sound pressure level according to EN ISO 1680 (tolerance +3 dB) The sound pressure level is listed in the selection and ordering data for the required motor. Weights The weight is listed in the selection and ordering data for the required motor. Modular mounting concept Prepared for mounting of rotary pulse encoder or brake Options See "Supplements to article numbers and special versions" Siemens D 81.8 · 04/2014 1/5 © Siemens AG 2014 Introduction Article number code 1 ■ Overview Structure of the article numbers for SIMOTICS FD motors The Article No. consists of a combination of digits and letters and is divided into three hyphenated blocks to provide a better overview, e.g.: 1LM1212-3AB31-1AA0 The first block (positions 1 to 7) identifies the motor series, system description and the efficiency; the second block (positions 8 to 12) defines the motor frame size, the number of poles as well as the line voltage and frequency; and the third block (positions 13 to 16) encodes the speed, type of construction, terminal box, separately driven fan and heat exchanger position. Ordering data: • Complete Article No. and order code(s) or plain text • If a quotation has been requested, please specify the quotation number in addition to the Article No. • When ordering a complete motor as a spare part, please specify the works serial No. for the previously supplied motor as well as the Article No. Note: The structure of the Article No. of SIMOTICS FD motors supports the widest possible range of combinations. To check a configured Article No., the selection guide DT Configurator must be used. The DT Configurator only permits technically implementable Article Nos. to be configured. Structure of the Article No.: Position: SIMOTICS FD low-voltage motors Positions 1 to 4: Motors without explosion protection Digit, letter, letter, Motors with explosion protection digit Air-cooled, enclosed version with self-ventilation, IC411 Air-cooled, enclosed version with forced-air cooling, IC416 Water-cooled with water-jacket cooling, IC71W Water-cooled with heat exchanger, IC86W Motors exclusively without explosion protection Air-cooled, open version with self-ventilation, IC01 Air-cooled, open version with forced-air cooling, IC06 Positions 5 to 7: Motor series Low-noise standard version 3 digits Increased output version Non-Siemens converter (standard) Non-Siemens converter (increased output) System description Mains-fed operation (DOL) Operation on SINAMICS converter with regulated infeed Operation on SINAMICS converter with unregulated infeed Operation on non-Siemens converter with regulated infeed Operation on non-Siemens converter with unregulated infeed Efficiency High Efficiency Premium Efficiency Positions 8 and 9: Frame size 315 355 Digit, letter 400 450 Position 10: No. of poles 4-pole 6-pole Letter 8-pole Position 11: Laminated core length Digit Position 12: Digit Line voltage Position 13: Digit Rated speed Encoded with 1 … 9; 9 requires order code N.. (e. g. N1Y) Position 14: Letter Type of construction Encoded with A ... G, J … K Position 15: Letter Terminal box position Encoded with A … F one terminal box, K …P two terminal boxes Position 16: Digit Separately driven fan – heat exchanger position 0: No separately driven fan/heat exchanger, 1 … 4: Separately driven fan position for air-cooled motors, 5: Heat exchanger, top Special order versions: Encoded – additional order code required Not encoded – additional plain text required 1/6 1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16 1 L 1 M M Q H N 1 L L 1 1 L P 1 400 V, 50 Hz 500 V, 50 Hz 690 V, 50 Hz – VSD 690 V, 50 Hz – DOL 460 V, 60 Hz 575 V, 60 Hz Deviating data requires order code M.. (e. g. M1Y) Siemens D 81.8 · 04/2014 1 1 1 1 2 3 4 5 0 1 2 3 4 2 3 3 3 4 4 A B A B B C D 1 … 7 1 2 3 4 5 6 9 1 ... 9 A ... K A ... P 0 ... 5 - Z 2 © Siemens AG 2014 Technical Information 2/2 2/2 2/2 Overview SIMOTICS FD motor series Versions of the SIMOTICS FD motor series 2/4 2/4 Design The basic design of the SIMOTICS FD motor series 2/5 2/5 Technical specifications Applicable standards and specifications Rating plate Motors specially designed for converter-fed operation Rated voltage Insulation Noise Forced-air cooling Reducing bearing currents Thermal torque limits (continuous duty) Maximum overload torques More information Water cooling Mechanical load, grease lifetime Motor protection Motor connection Motors specially designed for mains-fed operation (1LH1) Torque characteristic Calculation of the start-up time for direct-on-line starting Start-up procedure for three-phase motors with squirrel-cage rotor Connection and terminal boxes Terminal box mounting positions Bearings and lubrication Bearing assignment Bearing lifetime (nominal lifetime) Bearing system Insulated bearings for converter-fed operation Regreasing Grease lifetime and regreasing intervals Additional axial load for motors in the basic version Admissible cantilever forces at 50 Hz for motors with reinforced bearings 2/6 2/6 2/6 2/6 2/7 2/7 2/7 2/8 2/8 2/9 2/9 2/9 2/9 2/9 2/9 2/9 2/10 2/11 2/12 2/12 2/13 2/13 2/13 2/13 2/14 2/14 2/14 2/14 2/15 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Technical Information ■ Overview SIMOTICS FD motor series 2 1LL1 motors The motors are squirrel-cage induction motors with compact dimensions in a surface-cooled, open version with self-ventilation. The internal cooling circuit is supplied with cooling air from the outside. This is the reason why the output was able to be increased by approximately 30 % as compared to the 1LM1 motors. They have been specifically designed for converter-fed operation. Note: For frame size 355 and rated speeds of 3000 rpm and above, a shaft-mounted unidirectional fan is used. The 1LL1 motors are designed for indoor use. They must not be subjected to humid, salty or corrosive (e.g. hydrogen sulfide) atmospheres. A wide range of requirements are placed on state-of-the-art, high-output, low-voltage motors. They should be energy efficient, able to be flexibly used, quiet in operation and optimally adapted to the converter, for example. All of these requirements are fulfilled by the SIMOTICS FD series of motors, which have been specifically developed for this purpose. As a result of their flexibility and the wide range of versions available, SIMOTICS FD motors are suitable for all industries. Versions of the SIMOTICS FD motor series 1LM1 motors The motors are squirrel-cage induction motors with compact dimensions in a surface-cooled, enclosed version with self-ventilation. They have been specifically designed for converter-fed operation. Note: For frame size 355 and rated speeds of 3000 rpm and above, a shaft-mounted unidirectional fan is used. 1LM1 for converter-fed operation • Converter-fed operation, optimally harmonized to the SINAMICS drive system • Maximum A-weighted sound pressure level at rated speed is 79 dB(A) under no-load operation • IP54/IP55 degree of protection • Cooling method IC411, self-ventilated • Housing: cast-iron 1LQ1 motors The motors are squirrel-cage induction motors with compact dimensions in a surface-cooled, enclosed version with forcedair cooling. These motors can be operated with constant torque, also significantly below the rated speed, thanks to the forced-air cooling. They have been specifically designed for converter-fed operation. 1LQ1 for converter-fed operation • Converter-fed operation, optimally harmonized to the SINAMICS drive system • Maximum A-weighted sound pressure level at rated speed is 79 dB(A) or 85 dB(A) under no-load operation • IP54/IP55 degree of protection • Cooling method IC416, forced-air cooling • Housing: cast-iron 2/2 Siemens D 81.8 · 04/2014 1LL1 for converter-fed operation • Converter-fed operation, optimally harmonized to the SINAMICS drive system • Maximum A-weighted sound pressure level at rated speed is 79 dB(A) under no-load operation • IP23 degree of protection • Cooling method IC01, self-ventilated • Housing: cast-iron 1LP1 motors The motors are squirrel-cage induction motors with compact dimensions in a surface-cooled, open version with forced-air cooling. The internal cooling circuit is supplied with cooling air from the outside. This is the reason why the output was able to be increased by approximately 35 % as compared to the 1LM1 motors. These motors can be operated with constant torque, also significantly below the rated speed, thanks to the forced-air cooling. They have been specifically designed for converter-fed operation. The 1LP1 motors are designed for indoor use. They must not be subjected to humid, salty or corrosive (e.g. hydrogen sulfide) atmospheres. 1LP1 for converter-fed operation • Converter-fed operation, optimally harmonized to the SINAMICS drive system • Maximum A-weighted sound pressure level at rated speed is 79 dB(A) or 85 dB(A) under no-load operation • IP23 degree of protection • Cooling method IC06, forced-air cooling • Housing: cast-iron 1LH1 motors The motors are squirrel-cage induction motors with compact dimensions in an enclosed, water-cooled version. This is the reason why the output was able to be increased by approximately 30 % as compared to the 1LM1 motors. These motors can be operated with constant torque, significantly below the rated speed, as a result of the water cooling. They have been specifically designed for converter-fed operation, and are also available in a version for mains-fed operation. 1LH1 for converter-fed operation • Converter-fed operation, optimally harmonized to the SINAMICS drive system • Maximum A-weighted sound pressure level at rated speed is 79 dB(A) under no-load operation • IP54/IP55 degree of protection • Cooling method IC71W, water-cooled • Water-jacket cooling with either a copper or stainless steel jacket • Housing: cast-iron © Siemens AG 2014 Technical Information ■ Overview (continued) 1LH1 for mains-fed operation • Maximum A-weighted sound pressure level depending on the number of poles 68 to 72 dB(A) under no-load operation • IP54/IP55 degree of protection • Cooling method IC71W, water-cooled • Water-jacket cooling with either a copper or stainless steel jacket • Housing: cast-iron 1LN1 motors The motors are squirrel-cage induction motors with compact dimensions in a surface-cooled, enclosed version with air-towater heat exchanger. A separately driven fan is used to circulate air through the internal cooling circuit. This is the reason why the output was able to be increased by approximately 30 % as compared to the 1LM1 motors. These motors can be operated with constant torque, significantly below the rated speed, as a result of the forced-air cooling with air-to-water heat exchanger. They have been specifically designed for converter-fed operation. 1LN1 for converter-fed operation • Converter-fed operation, optimally harmonized to the SINAMICS drive system • Maximum A-weighted sound pressure level at rated speed is 79 dB(A) under no-load operation • IP54/IP55 degree of protection • Cooling method IC86W, air-to-water heat exchanger • Housing: cast-iron Siemens D 81.8 · 04/2014 2/3 2 © Siemens AG 2014 Technical Information ■ Design The basic design of the SIMOTICS FD motor series 1LQ1 forced-air cooled motors – enclosed version 1LH1 water-cooled motors with water-jacket cooling 2/4 Siemens D 81.8 · 04/2014 G_D081_XX_00436 1LP1 forced-air cooled motors – open version G_D081_XX_00435 1LL1 self-ventilated motors – open version G_D081_XX_00434 G_D081_XX_00433 1LM1 self-ventilated motors – enclosed version G_D081_XX_00432 G_D081_XX_00431 2 1LN1 water-cooled motors with air-to-water heat exchanger © Siemens AG 2014 Technical Information ■ Technical specifications Applicable standards and specifications 2 The SIMOTICS FD motors comply with the IEC 60034 series of international product standards for rotating electrical machines and, in particular, those parts that are listed in the table below. Title General specifications for rotating electrical machines Specification of the losses and efficiency of rotating electrical machines Starting performance of rotating electrical machines Terminal designations and direction of rotation for electrical machines Designation for types of construction, mounting and terminal box position (IM code) Terminal box cable entries Built-in thermal protection Noise limits of rotating electrical machines IEC standard voltages Methods of cooling of rotating electrical machines (IC code) Vibration severity of rotating electrical machines Vibration limits Degrees of protection for rotating electrical machines (IP code) International efficiency classes for rotating electrical machines (IE code) In addition, the following applies to Ex motors: General provisions Type of protection "n" (non-sparking) Areas containing flammable dust IEC/EN IEC 60034-1, IEC 60085 IEC 60034-2-1 DIN EN DIN EN 60034-1 IEC 60034-12 IEC 60034-8 IEC 60034-7 DIN EN 60034-12 DIN EN 60034-8 DIN EN 60034-7 – IEC 60034-11 IEC 60034-9 IEC 60038 IEC 60034-6 IEC 60034-14 – IEC 60034-5 IEC 60034-30 DIN 42925 DIN EN 60034-11 DIN EN 60034-9 DIN IEC 60038 DIN EN 60034-6 DIN EN 60034-14 DIN ISO 10816 DIN EN 60034-5 DIN EN 60034-30 IEC/EN 60079-0 IEC/EN 60079-15 IEC/EN 60079-31 DIN EN 60079-0 DIN EN 60079-15 DIN EN 60079-31 DIN EN 60034-2-1 Siemens D 81.8 · 04/2014 2/5 © Siemens AG 2014 Technical Information ■ Technical specifications (continued) Rating plate 3~ Mot. 1LM1 222-3AB72-2AC0-Z m: 1.78 t IP 55 SIMOTICS FD IM B3 Ta: -20…+40°C Th.Cl.: 180(H) Util.:155(F) nmax: 2500 1/min IEC/EN 60034-1 U [V] I [A] 480 D 550 P [kW] cosφ n [1/min] f [Hz] 395 0.90 1500 For SINAMICS converters (from firmware Version 4.6 and higher), the SIMOTICS FD motor series can be selected as motor category in the SINAMICS converter using the STARTER commissioning tool software or on the converter operator panel (AOP – Advanced Operation Panel). Eff. 50.50 96.0% Mot. design: FOR INVERTER DUTY ONLY Rated voltage UVW DEW0400 Made in Germany D-90441 Nürnberg G_D081_XX_00437 Line supply: 500V / 50Hz 3~ Mot. 1LH1 203-3AB71-2AB0-Z IP 55 SIMOTICS FD IM B3 Ta: -20…+40°C Th.Cl.: I [A] 480 D 790 NoN- xx9900006050001/2013 P [kW] cosφ n [1/min] f [Hz] Eff. Class 465 0.88 1487 The rated motor voltages are selected so that when operated with a SINAMICS converter, the available voltage is optimally utilized. Note: 180(H) Util.:130(B) When operating at the limits of voltage ranges A and B, the temperatures and overtemperatures exceed the limits specified in the standard. Under certain circumstances, this can affect the service life (continuous duty with undervoltage, on request). nmax: 1800 1/min IEC/EN 60034-1 U [V] The tolerance for the rated voltage is in accordance with DIN EN 60034-1. No rated voltage range is specified. In addition to the line voltage, the type of converter infeed (regulated or unregulated rectifier) defines the motor voltage that is available. A converter with controlled rectifier always provides the motor with a higher voltage than a converter with unregulated rectifier. Example of a rating plate for 1LM1 for converter-fed operation m: 2.0 t When operated with an alternative converter, the catalog data apply (thermal torque limits, maximum overload torques), with the exception of the sound pressure level, under the following boundary conditions: • The converter is operated with a rated pulse frequency of at least 2.5 kHz. • The converter can provide the rated voltage as listed in the catalog. This means that it is known whether the infeed (rectifier) is regulated or unregulated. If the infeed is unknown, an unregulated infeed should be assumed, and the motor output should be reduced (please inquire). NoN- xx9900006060001/2013 50 IE3 Eff. 96.3% Insulation Mot. design: FOR DIRECT ON-LINE OPERATION ONLY Line supply: 400V / 50Hz MAX. WASSERDRUCK / WATER PRESSURE 5 BAR Made in Germany D-90441 Nürnberg DEW0400 KÜHLW./COOL.WATER 40 L/MIN, 35°C G_D081_XX_00438 2 In accordance with EN 60034-1, the approximate total weight is specified on the rating plate. An extra rating plate can be supplied loose for all motors, order code K31. An extra rating plate for identification codes is also possible, order code Y82. As standard, the rating plate is in English. Example of a rating plate for 1LH1 for mains-fed operation All motors that comply with the international standard IEC 60034 30:2008 (Rotating electrical machines – Part 30: Efficiency classes of single-speed, three-phase, cage-induction motors (IE code)) have the efficiency class and the efficiency stamped on the rating plate. These efficiencies are based, according to the above standard, on the losses determined in accordance with standard IEC 60034-2-1:2007. The well-proven DURIGNIT IR 2000 insulation system is used adapted to the motor and converter. The insulation system corresponds to stress category or impulse insulation class (IIC) C (significant stress according to the preliminary standard DIN IES/TS 60034-18-41: 2007-04) for operation on a two-level converter, and is subdivided into two categories. The level of converter DC-link voltage and the rise times of the voltage are important factors in the voltage stress of the winding: • For a converter DC-link voltage of UDC,max < 700 V (line voltage 500 V with unregulated infeed), the insulation system IIC C 500 is used. • For a converter DC-link voltage of over UDC = 700 V up to UDC,max = 1035 V (line voltage 500 V with regulated infeed), the insulation system IIC C 690 is used. • The following applies for the voltage rise time: Ts > 0.5 µs. Motors specially designed for converter-fed operation For converter-fed operation with the outputs specified in the catalog, the motors can be utilized corresponding to thermal class 155 (F) (service factor 1.0). These motors have been specifically designed for converter-fed operation. The catalog data – especially the sound pressure level at the rated speed in no-load operation – are valid for operation with a SINAMICS converter (from firmware Version 4.6 and higher). In the case of a fault when connected to an IT supply system (ground fault), the insulation is excessively stressed. In this case, the process should be terminated as quickly as possible (t < 2 h), and the fault resolved. We do not recommend operation on TN supply systems with transition-point grounding. 2/6 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Technical Information ■ Technical specifications (continued) Noise Reducing bearing currents The motors have been designed, so that at every rated speed a maximum sound pressure level of • LPA=79 dB(A) for self-ventilated, forced-air cooled motors and motors with air-to-water heat exchanger (1LM1, 1LL1, 1LP1, 1LQ1, 1LN1) as well as with forced-air cooling in low-noise version (1LQ1, 1LP1, position 5 of Article No. = 2) • LPA = 85 dB(A) for motors with forced-air cooling in increased output version (1LQ1, 1LP1, position 5 of Article No. = 3) • LPA =78 dB(A) for water-cooled motors (1LH1) To specifically reduce and prevent damage caused by bearing currents, the system must be considered as a whole, which comprises the motor, converter, and driven machine. To prevent damage caused by bearing currents, the SIMOTICS FD converter-fed motors are equipped with insulated bearings at NDE as standard. Important factors which will help to prevent bearing currents include: • Set up a properly meshed grounding system in the system as a whole, with low impedance for high-frequency currents • No potential difference between the motor, converter, and driven machine - Use symmetrical, shielded connecting cables - Connect the cable shield at both ends over the greatest possible surface area (360° contact) - Use equipotential bonding conductors between the motor and the driven machine, the motor and the converter, within the motor as well as between the terminal boxes and the HF grounding position on the motor housing • Attach iron cores above the motor connecting cable at the converter output (selection and dimensioning through your Siemens sales partner) • Insulate a motor bearing • Limit the voltage rate of rise by using an output filter to dampen harmonic components in the output voltage • Implement common-mode filter by employing damping cores to reduce common-mode components • Use converters with a low switching frequency • Use cables with a symmetrical cable cross-section: Forced-air cooling The separately driven fans of motors of the 1LQ1 and 1LP1 series as well as the separately driven fans in the air-to-water heat exchangers for the 1LN1 series are especially quiet. The line voltage and frequency for the forced-air cooled motors are specified, as for the motor itself, in position 12 of the Article No. Technical specifications of the separately driven fan motor (1LQ1, 1LP1) 1) Frame 5th size position of the Article No. Mounting position Prated, Irated, Prated, 50 Hz 400 V, 50 Hz 60 Hz Irated, 460 V, 60 Hz kW A kW A 315 2 radial 1.5 3.2 2.24 3.9 2 axial 1.75 3.2 o.r. o.r. 3 radial 5.5 10.5 5.5 9.1 2 radial 1.5 3.2 2.24 3.9 2 axial 1.5 3.2 2.24 3.9 3 radial 5.5 10.5 5.5 9.1 355 L1 PE L3 L2 Prated, Irated, Prated, 50 Hz 400 V, 50 Hz 60 Hz Irated, 460 V, 60 Hz kW A kW A 315 3 6.1 3.45 5.8 355 5.5 6.3 10.3 9.9 1) L1 PE L3 L2 L3 L2 Technical specifications of the separately driven fan motor (1LN1) 1) Frame size L1 PE Concentric Cu or Al screen PE Steel reinforcement G_D011_EN_00065 when operated with SINAMICS converters (from firmware Version 4.6 and higher) in no-load operation is maintained. The motor data on the rating plate can deviate from this. Siemens D 81.8 · 04/2014 2/7 2 © Siemens AG 2014 Technical Information ■ Technical specifications (continued) G_D081_EN_00442 0.4 0.8 1.2 2 n/nrated2.4 Thermal torque limit characteristic for the 1LP1 and 1LN1 series 0.4 0.8 1.2 1.6 2 n/n rated 2.4 Torque Thermal torque limit characteristic for the 1LM1 series G_D081_EN_00440 1.10 1.00 T/Trated 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 1.10 1.00 T/Trated 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 0 0.4 0.8 1.2 1.6 2 n/nrated 2.4 Speed Thermal torque limit characteristic for the 1LH1 series Maximum overload torques 0.4 0.8 1.2 1.6 2 n/nrated 2.4 Speed Torque 1.10 1.00 T/Trated 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 0 G_D081_EN_00441 Thermal torque limit characteristic for the 1LL1 series The maximum overload torque output from the motor is defined by the overload torque characteristic over the complete speed control range. The reference variable is the breakdown torque at rated speed. The breakdown torque is calculated from the breakdown torque ratio and the rated torque. Operation at the maximum overload torque is only briefly permissible, for instance, when accelerating. The speed control range is limited by the mechanical speed limit, which depends on the motor's mechanical design. 0.4 0.8 1.2 1.6 2 n/nrated 2.4 Speed 1.10 1.00 T/T B 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 G_D081_EN_00444 0 0 0.4 0.8 1.2 SIMOTICS FD overload torque characteristic Siemens D 81.8 · 04/2014 1.6 2 n/n N 2.4 Speed Thermal torque limit characteristic for the 1LQ1 series 2/8 1.6 Speed Speed Torque 1.10 1.00 T/Trated 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 0 G_D081_EN_00443 1.10 1.00 T/Trated 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 0 G_D081_EN_00439 Torque The thermal torque limit characteristics of the SIMOTICS FD motor series define the maximum load torque for continuous duty (S1) over the complete speed control range. The characteristics are different for all of the cooling methods. The speed control range is limited by the mechanical speed limit, which depends on the motor's mechanical design. Torque 2 Torque Thermal torque limits (continuous duty) © Siemens AG 2014 Technical Information ■ Technical specifications (continued) Torque characteristic Water cooling • The catalog data for motors with water cooling (1LH1) or with air-to-water heat exchanger (1LN1) are applicable for the following coolant flow rates: • d[/dt = 40 l/min for the 1LH1 series • d[/dt = 115 l/min for the 1LN1 series • d[/dt = 150 l/min for the 1LN1 series (frame size 355) The torque generated by a three-phase motor at its shaft varies considerably within the speed range n = 0 to n = ns. The characteristic curve of the torque as a function of the speed of a three-phase motor with squirrel-cage rotor is shown in the following diagram. Motor protection A motor protection function can be implemented using the I²t sensing circuit implemented in the converter software. If required, more precise motor protection can be afforded by direct temperature measurement using KTY84 sensors (standard scope of delivery), Pt100 resistance thermometers or PTC thermistors in the motor winding. Some converters from Siemens determine the motor temperature using the resistance of the temperature sensor. They can be set to a required temperature for alarm and tripping. If Pt100 resistance thermometers are ordered for winding temperature monitoring (order code A61) or PTC thermistors (order code A12), the standard KTY84 temperature sensors are omitted. A combination of A25 and A61 or A25 and A12 is possible, additional charge on request. KTY or Pt100 sensors are evaluated as described above, e.g. in the converter. For motors for mains-fed operation, the 3RS10 temperature monitoring device that is part of the protection equipment can be ordered separately. For further details, see Catalog IC 10. Motor protection is implemented using basic insulation. If protective separation is required, this must be implemented when designing the temperature monitoring system. Motor connection When connecting the motors, it is important to consider the restrictions for mains-fed machines as well as the maximum conductor cross-sections permitted for the converter. Motors specially designed for mains-fed operation (1LH1) The 1LH1 series also includes motors specifically for mains-fed operation. Contrary to motors specifically for converter-fed operation, it is possible to switch between star and delta connection. TLR Tp Ta T Trated TL When motors are operated at speeds above the rated speed, the mechanical smooth running operation and the bearings are subjected to greater mechanical stress. This reduces the grease lifetime and the bearing lifetime. More detailed information is available on request. The SIMOTICS FD series optionally has spent grease removal at both bearings. TB Tm Mechanical load, grease lifetime G_D081_EN_00200 More information 0 nrated ns n Trated Tm TL Ta Rated torque Motor torque Load torque Acceleration torque TLR Locked-rotor torque TB Breakdown torque Tp Pull-up torque nrated Rated speed ns Synchronous speed The values for locked-rotor torque and breakdown torque as well as for locked-rotor current for a specific motor can be found in the selection and ordering data. The limit for the mechanical overload capability is the breakdown torque. According to IEC/EN 60034-1, at rated voltage and at rated frequency, induction motors must have an overload capability of up to 160 % of the rated torque for 15 seconds. If not agreed otherwise, for induction motors, the minimum pullup torque at rated voltage must have the value specified in the following rated torques. For three-phase motors without pole changing with a rated output equal to or greater than 100 kW, the following applies: • 0.3 times rated torque and at least 0.5 times the locked-rotor torque According to IEC/EN 60034-1, the following tolerances are admissible: • For locked-rotor torque, from -15 to 25 % of the stated lockedrotor torque • For locked-rotor current, up to 20 % of the stated locked-rotor current without lower limit • For the breakdown torque, up to -10 % of the specified breakdown torque • For pull-up torque, -15 % of the guaranteed value. Taking these tolerances into account, the locked-rotor torque must be sufficiently higher than the breakaway torque of the driven machine; and the motor torque must constantly exceed the load torque during start-up until the operating speed is achieved. In the case of squirrel-cage motors, the locked-rotor torque and breakdown torque are listed in the selection and ordering data as multiples of the rated torque. The normal practice is to start squirrel-cage motors directly on line. The torque class indicates that with direct-on-line starting, even if there is an undervoltage of 5 %, it is possible to start up the motor against a load torque of • 130 % (for CL 13) • 100 % (for CL 10) of the rated torque. Siemens D 81.8 · 04/2014 2/9 2 © Siemens AG 2014 Technical Information ■ Technical specifications (continued) The start-up time from n = 0 to n = nb can be approximately determined from the average acceleration torque. tst = 300 0 20 60 80 % 100 Speed 40 Motors with CL 10 torque class 600 % 500 I 400 300 T 200 I 100 T 0 G_D081_EN_00202 maximum load torque during the starting The total moment of inertia is made up of the motor moment of inertia plus the moment of inertia of the driven machine and the coupling or belt pulleys and is converted to the speed of the motor shaft. Limit values for the start-up curve of three-phase squirrel-cage motors for voltages up to and including 690 V are included in IEC/EN 60034. If problem-free starting is not possible due to a high moment of inertia and/or a high load torque, a larger motor or a three-phase motor with a SINAMICS frequency converter can be used for SIMOTICS FD motors. A mechanical solution for coping with heavy starting is to use a starting coupling, whose application is limited by its capability to absorb heat. T 0 20 40 60 80 %100 Speed G_D081_EN_00206 0 Start-up time in s Total moment of inertia in kgm2 Operating speed in rpm Average acceleration torque in Nm tst J nop Taav T 200 ∑ J nop 9.55 T aav Tm Taav Torque and current I 400 Torque curves for direct starting 100 Torque and current 2 G_D081_EN_00201 Calculation of the start-up time for direct-on-line starting 600 % 500 Motors with CL 13 torque class maximum load torque during starting TL The rated torque can be calculated as follows: Trated= 9.55 Prated 1000 nrated Trated Rated torque in Nm nrated Rated speed in rpm Prated Rated output in kW The rated speed of the motor differs from the synchronous speed by the slip srated. Where: srated= ns – nrated 100 ns srated Slip in % Synchronous speed in rpm nS nrated Rated speed in rpm 2/10 Siemens D 81.8 · 04/2014 Tm TL Taav nop nop n Motor torque Load torque average acceleration torque Operating speed Determination of the average acceleration torque © Siemens AG 2014 Technical Information ■ Technical specifications (continued) 0 20 40 60 % 80 200 300 400 % 500 n/n S Unfavorable star-delta starting 250 % 200 150 100 50 The locked-rotor current without a resistor or reactor is slightly higher in both phases than with direct on-line starting. 0 TL 20 40 60 % 80 100 The electronic SIKOSTART motor starter can be used to better implement starting based on this principle. This device limits the torque and current while starting. 200 I/I rated Any inquiries regarding start-up procedures must include the following information: 1. Required output and rated speed of the driven machine 2. Planned motor speed 3. Load torque of the driven machine, depending on the speed of the driven machine or the motor speed 4. Total external moment of inertia and rated speed of the driven machine or referred to the motor speed 5. Number of starts in a specific time period and duty cycle or 6. Characteristics and number of operating cycles in a certain time (method of braking) TL 100 T/Trated Soft starting for motors with squirrel-cage rotor can also be achieved with short-circuit soft starting or a resistor can be connected in one phase during start-up. The locked-rotor torque can be arbitrarily reduced with the help of this circuit. G_D081_EN_00204 50 The torque curve can be approximately reduced by the square of the voltage and the current curve linearly with the voltage by reducing the voltage at the motor terminals with the help of a starting transformer or starting resistors. Starting at rated current is possible when using a converter (second diagram). 150 2 G_D081_EN_00205 The first diagram shows a case in which star-delta start-up is not appropriate because the excessive load torque causes the premature switchover which in turn causes a high torque and current surge that renders star-delta starting ineffective. 250 % 200 100 I/I rated Three-phase motors with squirrel-cage rotors should, as far as possible, be started directly on-line. • It should be noted that for any specific motor, the torque and current characteristics are given, independent of the load to be started. Star-delta starting for motors with squirrel-cage rotor is to be used if low locked-rotor currents (e.g. specified by the local power utility) or an especially low starting torque (soft starting) is specified. Locked-rotor torque, breakdown torque and all other torque values as well as the locked-rotor current are 25 to 30 % of the values at direct-on-line starting. • The motor torque must be sufficiently higher than the load torque during start-up in the star stage. The change from star to delta must not occur before approximately the operating speed. T/Trated Start-up procedure for three-phase motors with squirrel-cage rotor 300 400 % 500 n/n S Correct star-delta starting Siemens D 81.8 · 04/2014 2/11 © Siemens AG 2014 Technical Information ■ Technical specifications (continued) Connection and terminal boxes Terminal box mounting positions ■ – – – – – ■ Both DE (right and left) Both NDE (right and left) – – – – ✓ – ✓ 9) – ✓ ✓ ■ ■ – – – – ✓ – ✓ 9) – 8) 9) 8) 9) – Bottom Top 4) Right – – – ✓ 7) ✓ 7) ✓ 7) ✓ ■ ■ ✓ ■ ■ – – – – – – – – – – – – – ✓ ✓ – ✓ ✓ – ✓ ✓ – ✓ ✓ – – – ✓ ✓ 7) ✓ 7) ■ 5) ■ ■ ■ ■ ■ – – – – – ■ 8) – – – – ✓ 8) – – – – – ■ 8) ■ 8) – – – – – – – – – – – – – – – – – – – – – – – – – – – – ■ 8) ■ 8) – – – – – – – – – – – – – – – – – ✓ ■ 2) ■ 2) ✓ ■ ■ ■ – – ■ – – ✓ – – ✓ – – – ✓ ✓ – ✓ ✓ – ✓ ✓ – – – – – – ✓ 7) ✓ 7) ✓ 7) ✓ ■ ■ ✓ ■ ■ – – – – – – – – – – – – – ✓ ✓ – ✓ ✓ – ✓ ✓ – ✓ ✓ – – – ✓ ✓ 7) ✓ 7) ■ ■ ■ ■ ■ ■ – – – ■ 2) ■ ■ 8) – – – – ✓ 8) – – – – – ■ 8) ■ 8) ✓ ✓ – – – ✓ – – – – – ✓ 7) – – – ■ ■ – – – – – – – – – – – ■ 8) ■ 8) ✓ ✓ – – – ✓ ✓ – – – – ✓ 7) – – – ■ ■ – ■ ■ – ■ ■ – – – – – – – – – – – – – ✓ ✓ – ✓ 9) ✓ 9) – ✓ ✓ – – – – – – – ✓ 7) ✓ 7) – ■ ■ – ■ ■ – – – – – – – – – – – – – ✓ ✓ – ✓ 9) ✓ 9) – ✓ ✓ – ✓ ✓ – – – – ✓ 7) ✓ 7) – ■ ■ – ■ ■ – – – – – – – ■ – – – – – – – – – – – ■ – – – – – – – – – ■ – – – – – ■ – – – – ■ ✓ 7) ■ – – – – ✓ ✓ ✓ 9) – – ■ ✓ 7) ■ – – – – ✓ ✓ ✓ 9) ✓ 8) 9) 8) 9) Left – ✓ ✓ – – – DE – ✓ ✓ – ✓ ✓ – NDE Bottom NDE – Top 4) ✓ – – ✓ – – Left ■ – – ■ – – 8) 9) – Right DE 8) 9) Both right (NDE and DE) IM V1 ✓ ■ ■ ✓ ■ ■ 1LM1, 1LQ1, 1LL1, 1LP1 motors – with IC411, IC416, IC01, IC06 cooling method Version with one terminal box Standard version (DE top) 3) 1 ■ ✓ – – ✓ ✓ ■ ✓ – – – DE right 3) 10) 2 – – ✓ – ✓ ■ – – ✓ – – DE left 3) 10) – – ✓ – ✓ ■ – – ✓ – – NDE top 6) 3 ■ ✓ – – ✓ ✓ ■ ✓ – – ✓ 7) NDE right 6) 10) – – ✓ – ✓ ■ – – ✓ – ✓ 7) 6) 10) NDE left – – ✓ – ✓ ■ – – ✓ – ✓ 7) Version with two terminal boxes Both top (NDE and DE) 6) 4 ■ 8) ✓ 8) – – – – ■ 8) ✓ 8) – – – Both left (NDE and DE) 6) 10) – – ■ 8) – – – – – ■ 8) – – Both right (NDE and DE) 6) 10) – – ■ 8) – – – – – ■ 8) – – Both DE (right and left) – – – – – – – – – – – Both NDE (right and left) – – – – – – – – – – – 1LH1 motors – with IC71W cooling method Version with one terminal box Standard version (DE top) 2 ■ ✓ – – ✓ 2) ✓ 2) ■ ✓ – – – DE right – – ✓ – ✓ 2) ■ 2) – – ✓ – – DE left – – ✓ – ✓ 2) ■ 2) – – ✓ – – NDE top ■ ✓ – – ✓ ✓ ■ ✓ – – ✓ 7) NDE right – – ✓ – ✓ ■ – – ✓ – ✓ 7) NDE left – – ✓ – ✓ ■ – – ✓ – ✓ 7) Version with two terminal boxes Both top (NDE and DE) ■ 8) ✓ 8) – – – – ■ 8) ✓ 8) – – – Both left (NDE and DE) – – ■ 8) – – – – – ■ 8) – – Both right (NDE and DE) – – ■ 8) – – – – – ■ 8) – – Both DE (right and left) – – ✓ – ✓ 2) ■ 2) – – ✓ – – Both NDE (right and left) – – ✓ – ✓ ■ – – ✓ – ✓ 7) 1LN1 motors – with IC86W cooling method Version with one terminal box DE top – – – – – – – – – – – Standard version (DE right) – – ✓ – ✓ ■ – – ✓ – – DE left – – ✓ – ✓ ■ – – ✓ – – NDE top – – – – – – – – – – – NDE right – – ✓ 9) – ✓ ■ – – ✓ 9) – ✓ 7) 9) 9) NDE left – – ✓ – ✓ ■ – – ✓ – ✓ 7) Version with two terminal boxes Both top (NDE and DE) – – – – – – – – – – – Both left (NDE and DE) – – ■ – – – – – ■ – – NDE IM B5 with support foot DE Bottom Top 4) Left Right IM B35 NDE DE Bottom Top 4) Fig. Type of construction 1) on IM B3 page 2/13 Cable entry Left Terminal box position Right 2 8) 9) 8) 9) – ■ ✓ 7) ■ ■ Standard version ✓ Combination is possible 1) When ordering the optional type of construction IM V15, IM V5 or IM V6, the position of the terminal box must be checked with regard to lifting method, accessibility of feet bolts, etc. 2) Not with terminal box 1XB1631. 3) 4) 5) The radially mounted separately driven fan unit must be mounted on the left or right side. 6) The radially mounted separately driven fan unit cannot be mounted on the same side as the terminal box. If the terminal box and separately driven fan unit are both mounted on the top, or on the same side, NDE cable entry is not possible for any terminal box. 7) Note bending radius, where applicable. 8) The cable entries of the two terminal boxes must be mounted in the same direction. The position and direction "top" corresponds to the housing side opposite to the one with feet mounted to it. For all types of construction, a housing with feet is used, but in the case of IM V1, the feet are not used. 9) Cable entry top, only when the water connection of the cooler is on the other side. 10) Not for 1LL1 and 1LP1 motors. 2/12 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Technical Information ■ Technical specifications (continued) Fig. 1 Fig. 2 2 G_D081_XX_00449 G_D081_XX_00448 Fig. 3 Fig. 4 G_D081_XX_00451 G_D081_XX_00450 Bearings and lubrication Bearing system Bearing assignment For the admissible vibration values measured at the bearing plate, evaluation zones A and B specified in ISO 10816 are applicable in order to achieve the calculated lifetime under continuous duty. If higher vibration speeds will occur under the operating conditions, special arrangements will be necessary (please inquire). The bearing selection tables are only intended for planning purposes. Authoritative information on the actual type of bearings fitted in motors already supplied can be obtained by the factory by quoting the serial number or can be read from the lubrication plate. No. of poles Bearing design Frame size Design DE Bearing type 315 355 IM B3 6218 C3 Speed Bearing lifetime rpm h 4 3000 40000 4 1500 40000 6 1000 40000 8 750 40000 NDE Bearing type 6218 C3 IM B5/IM B35 6218 C3 6218 C3 IM V1 6218 C3 6218 C3 IM B3, K20 NU320E 6218 C3 IM B3 6220 C3 6220 C3 IM B5/IM B35 6220 C3 6220 C3 IM V1 7220 B + 6220 C3 6220 C3 IM B3, K20 NU322E 6220 C3 Bearing lifetime (nominal lifetime) The nominal bearing lifetime is defined according to standardized calculation procedures (DIN ISO 281) and is reached or even exceeded for 90 % of the bearings when the motors are operated in compliance with the data provided in the catalog. Generally, the bearing lifetime is defined by the bearing size, the bearing load, the operating conditions, the speed and the grease lifetime. The bearing lifetime of motors with horizontal mounting is 40 000 hours if there is no additional axial loading at the coupling output and 20 000 hours when utilized according to the maximum admissible load. In the basic bearing system, the floating bearing is situated at the non-drive end (NDE) and the located bearing is situated at the drive end (DE). The bearing system is axially preloaded with a spring element to ensure smooth running of the motor backlash-free. This is not the case in versions with cylindrical roller bearings. The bearings of these motors must always run under adequate radial force (motors must not be operated on a test bed without additional radial loads). For increased cantilever forces (e.g. belt drives), reinforced bearings can be used at the drive end (DE). Order code K20 Shaft seal and degree of protection The standard degree of protection for the 1.M1, 1.Q1, 1.H1 and 1.N1 motor series is IP55. When the following operating speeds are exceeded, the degree of protection falls to IP54: • > 3000 rpm for frame size 315 • > 2670 rpm for frame size 355 (in combination with order code M61 or K20: > 2430 rpm) Siemens D 81.8 · 04/2014 2/13 © Siemens AG 2014 Technical Information ■ Technical specifications (continued) 2 Insulated bearings for converter-fed operation Vertical installation – basic version An insulated bearing is installed at NDE. Speed Regreasing interval up to CT 40 °C/ Grease quantity rpm Frame size Regreasing Regreasing with an M10 × 1 flat greasing nipple according to DIN 3404 is provided. 315 355 Specifications for regreasing intervals, grease type and quantity and any other data can be found on the lubrication plate or rating plate. 750 6000 h/25 g 6000 h/50 g 1000 6000 h/25 g 6000 h/50 g 1500 5000 h/25 g 6000 h/50 g Grease lifetime and regreasing intervals 1800 5000 h/25 g –/– Horizontal installation – basic version 2500 2500 h/25 g –/– Speed Regreasing interval up to CT 40 °C/ Grease quantity Horizontal installation (IM B3 only) for reinforced bearing (K20): rpm Frame size Speed Regreasing interval up to CT 40 °C/ Grease quantity DE/NDE rpm Frame size 315 355 750 6000 h/25 g 6000 h/30 g 1000 6000 h/25 g 6000 h/30 g 1500 1800 3000 3600 6000 h/25 g 6000 h/30 g 6000 h/25 g 6000 h/30 g 3000 h/25 g 2000 h/30 g 2000 h/25 g 2000 h/30 g 315 355 750 4000 h/45 g/20 g 4000 h/50 g/30 g 1000 3000 h/45 g/20 g 3000 h/50 g/30 g 1500 2000 h/45 g/20 g 2000 h/50 g/30 g 1800 1500 h/45 g/20 g 1500 h/50 g/30 g Additional axial load for motors in the basic version Additional axial load for motors in horizontal type of construction – basic version Frame size Type 3000 rpm 1500 rpm 1000 rpm 750 rpm Load direction 315 355 Tensile Thrust Tensile Thrust Tensile Thrust Tensile Thrust N N N N N N N N 1..1…-…1. 3500 1900 4700 3100 5500 3900 6300 4600 1..1…-…3. 3500 1800 4700 3000 5500 3800 6200 4500 1..1…-…5. 3300 1700 4500 2900 5300 3600 6000 4300 1..1…-…7. 3300 1700 4500 2900 5300 3600 6000 4300 1..1…-…5. 4400 2100 6000 3700 6800 4500 7700 5400 1..1…-…7. 4400 2100 6000 3700 6700 4400 7700 5400 Tensile: additional axial load in DE direction Thrust: additional axial load in NDE direction Additional axial load for motors in vertical type of construction – basic version Frame size Type 3000 rpm 1500 rpm 1000 rpm 750 rpm Shaft extension pointing downwards Load 315 355 downwards upwards downwards upwards downwards upwards downwards upwards N N N N N N N N 1..1…-…1. 1100 6100 2400 7400 2700 8900 3500 9700 1..1…-…3. 600 6600 1900 7900 2000 9600 2800 10400 1..1…-…5. 100 7100 1400 8400 1500 10200 2300 11000 1..1…-…7. – 7500 1) 1000 8800 1200 10500 2000 11300 1..1…-…5. 7800 7400 7800 8700 6200 11100 6200 11900 1..1…-…7. 7500 7700 7500 9000 5600 11700 5600 12500 Data for 3000 rpm and 1500 rpm are applicable to 4-pole motors. Data for 1000 rpm and 750 rpm are applicable to 6- or 8-pole motors. 1) Without additional axial load, the bearing lifetime is less than 20 000 h. 2/14 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Technical Information ■ Technical specifications (continued) Motors in the basic version are designed for flexible couplings. The following weight limits are admissible for coupling halves: • Frame size 315 – 40 kg • Frame size 355 – 60 kg 2 60 kN 50 FQ FQ x inadmissible range 40 G_D081_EN_00452 Admissible cantilever forces at 50 Hz for motors, frame size 315, in IM B3 type of construction with reinforced bearings (order code K20) 30 FQ max 20 admissible range 10 9.315 inadmissible range 0 0 20 40 60 Bearings DE: NDE: Bearing lifetime: Torsional torque: Minimum cantilever force: 80 100 120 140 160 mm 180 x NU320-E 6218 20 000 h 5600 Nm rising 9.315 kN FQ 40 kN 35 FQ x inadmissible range 30 FQ Max 25 G_D081_EN_00463 Admissible cantilever forces at 50 Hz for motors, frame size 355, in IM B3 type of construction with reinforced bearings (order code K20) 20 admissible range 15 10.702 10 inadmissible range 5 0 0 50 100 150 200 mm 250 x Bearings DE: NU322-E NDE: 6220 Bearing lifetime: 20 000 h Torsional torque: 7500 Nm rising Minimum cantilever force: 10.702 kN The maximum cantilever force is limited to 40 kN. Siemens D 81.8 · 04/2014 2/15 © Siemens AG 2014 Technical Information Notes 2 2/16 Siemens D 81.8 · 04/2014 3 © Siemens AG 2014 System Components 3/2 3/2 3/2 3/2 3/2 3/2 3/3 3/3 3/3 3/4 3/8 3/10 3/10 3/11 3/11 3/11 3/11 3/12 Configuring Configuring the motor SIMOTICS FD Structure of catalog motor selection tables Ambient conditions and site altitude Duty types Engineering the drive system General information Voltage supply via the converter Engineering the drive system Catalog versions and special versions Noise emission for operation on SINAMICS converter EMC Water cooling (1LH1 and 1LN1 motors) Cooling circuit in the application Cooling water quality Materials used in the motor cooling circuit Inhibitors, anti-freeze, biocides 3/13 3/13 Condition monitoring system SIPLUS CMS condition monitoring systems for the continuous condition monitoring of motors 3/14 3/14 3/14 Couplings Siemens Integrated Drive Systems FLENDER couplings – Part of the drive system Siemens D 81.8 · 04/2014 © Siemens AG 2014 System Components Configuring Configuring the motor ■ Overview SIMOTICS FD 3 Motors of the SIMOTICS FD series are designed for a wide range of different applications. For outdoor use, special applications or specific boundary conditions, an inquiry must be made to establish whether a catalog version is suitable or a special version is recommended. This is particularly the case with: • Applications with increased mechanical stress due to vibration or shocks • Installation on deck (ships) • Frame sizes V15, V5 and V6 • Piston engines, hackers, crushers, shredders, shearing machines • Deviating rated motor voltages, speeds or outputs Structure of catalog motor selection tables The SIMOTICS FD motors have been optimized for operation with converters of the SINAMICS range. The selection tables are therefore structured as follows: 1. Motor type – cooling method (1LM1, 1LL1, 1LH1, …) 2. Line voltage/frequency (400 V, 50 Hz; 460 V, 60 Hz; …) 3. Type of infeed (regulated or unregulated) 4. Rated speed (1500 rpm, 1800 rpm, …) In the selection tables, a SINAMICS converter is also recommended for each motor. The motor data is specified for operation on this converter, or on another converter that is comparable with regard to the output voltage (section "Voltage supply"). Reduction factor kHT for non-standard site altitudes and/or coolant temperatures for 1LH1 and 1LN1 water-cooled motors Site altitude above sea level Coolant temperature (water) m ≤ 25 °C ≤ 30 °C ≤ 35 °C ≤ 40 °C ≤ 45 °C ≤ 1000 1.00 0.95 0.90 0.84 0.79 ≤ 1500 0.97 0.92 0.87 0.81 0.77 ≤ 2000 0.94 0.89 0.85 0.79 0.74 Duty types The operating data specified in the catalog for SIMOTICS FD motors is applicable to duty type S1 (continuous duty according to DIN EN 60034-1). Overloading is possible in the case of duty types S2 (short-time duty), S3 (intermittent periodic duty) and S6 (continuous operation periodic duty). The applicable overload factors can be taken from the tables below for these three duty types. The overload factors are valid on starting when the motor is cold and when the resulting torque is less than or equal to the maximum overload torque (TB). If the motor is prewarmed due to recent operation or it is in a thermal steady-state due to continuous duty (S1), thermal class 155 (F) will be exceeded under overload conditions. Depending on the amount of overload, the maximum winding temperature can be exceeded and the motor can be damaged. Overload factors for short-time duty (S2) Ambient conditions and site altitude Duty type Short-time duty The output data specified in the catalog is applicable to ambient temperatures of -20 to 40 °C and site altitudes of up to 1000 m above sea level. For ambient conditions outside this range, derating is necessary. S2 10 min 1.80 30 min 1.20 60 min 1.05 Reduction factor kHT for non-standard site altitudes and/or coolant temperatures for 1LM1, 1LL1, 1LQ1 and 1LP1 air-cooled motors Intermittent periodic duty (S3) Site altitude above sea level Coolant temperature (air) For motor 1LM1, 1LL1 Duty type m 30 °C … 40 °C ≤ 45 °C ≤ 50 °C ≤ 55 °C ≤ 60 °C ≤ 1000 1.00 0.96 0.92 0.87 0.82 ≤ 1500 0.97 0.93 0.89 0.84 0.80 ≤ 2000 0.94 0.90 0.86 0.82 0.77 For water-cooled motors, the data specified in the catalog is based on a coolant inflow temperature of 25 °C, whereby derating is necessary for a coolant temperature of 25 °C and a site altitude of > 1000 m. Deviating installation conditions can be clarified on request. Factor S3 Intermittent periodic duty 1LQ1, 1LP1, 1LH1, 1LN1 Factor 60 % 1.16 1.22 80 % 1.02 1.07 Continuous operation periodic duty (S6) Duty type Periodic duty S6 25 % Factor 1.70 40 % 1.35 60 % 1.18 With 1LQ1, 1LP1, 1LH1 and 1LN1, it is not permitted for the cooling to be interrupted. 3/2 Siemens D 81.8 · 04/2014 © Siemens AG 2014 System Components Configuring Engineering the drive system ■ Overview The SIMOTICS FD motors have been specially tuned to the converters of the SINAMICS G130, SINAMICS G150, SINAMICS S120, SINAMICS S150 and SINAMICS G120P series. SIMOTICS FD must be selected as the motor type during commissioning of the SINAMICS converter in the STARTER commissioning tool, or in the user interface. The motors can also be operated with other converters under certain boundary conditions. General information For optimum dimensioning of the motors with regard to heating and noise emission for converter-fed operation, the following details are necessary: • Type of infeed • Maximum voltage available to the motor • Converter pulse frequency, if applicable • Required rated speed • Required rated output, cooling method and degree of protection of the motor (selection tables) The insulation system of the motors corresponds to thermal class 180 (H). The motors are utilized in accordance with thermal class 155 (F) as standard. For utilization of the motors in accordance with thermal class 130 (B), the output must be reduced by 14 % (derating factor 0.86). Voltage supply via the converter To select a catalog version of the SIMOTICS FD motor series specifically designed for converter-fed operation, the voltage available to the motor must be known. The line voltage and the configuration of the converter at the line side (infeed, rectifier or line-side converter – referred to below as the infeed) are important here. M Supply system Infeed DC link Inverter G_D081_EN_00453 The SIMOTICS FD motor series offers scope for optimizing the drive system that comprises the frequency converter and the motor with regard to different criteria. This focuses on the following motor characteristics: • Increased efficiency: SIMOTICS FD motors specially designed for converter-fed operation are characterized as standard by a high degree of efficiency – comparable to IE2 motors for mains-fed operation. For selected cooling methods (IC411 –1LM1 self-ventilated, IC416 – 1LQ1 forced-air cooled, IC71W – 1LH1 water-cooled), motors with increased efficiency are also available – comparable to IE3 motors for mains-fed operation. For motors with increased efficiency (position 7 of the Article No. = 3) in frame size 315, depending on the individual case, the thermal utilization for converter-fed operation can also comply with thermal class 130 (B) instead of thermal class 155 (F). The specified efficiencies are applicable for motor voltages in accordance with DIN EN 60034-1 N. • Minimal noise emission for operation on SINAMICS converters: Noise emission is minimized, especially in the range of rated speed, thanks to a perfectly matched drive system comprising a SINAMICS converter and SIMOTICS FD motor. This has been achieved on the one hand with a new electrical and mechanical design of the motor, and on the other hand using a new pulse pattern in the SINAMICS converter series that has been specially optimized for SIMOTICS FD motors. • Optimum voltage utilization: The voltage supplied by the converter is optimally utilized. This reduces the motor current and has a positive effect on the converter either in the form of higher current reserves or lower costs for the Motor Module. Motor Drive system Unregulated infeed If the infeed involves a line-commutated converter (unregulated infeed), i.e. a thyristor or diode rectifier (in some cases also an IGBT module), the maximum available motor voltage is lower than the line voltage. The DC link voltage and, therefore, also the output voltage of the converter is not normally regulated and changes as soon as fluctuations in line voltage occur. The SINAMICS converter series comprises two different variants of unregulated infeed: • Basic Infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 Basic Line Module (BLM, SINAMICS G120P): - Line-commutated converters - Suitable for infeed operation (two-quadrant operation) - Power semiconductors: thyristors/diodes - Line harmonics: total harmonic distortion factor of the line current THD(I) up to 45 % - Low voltage load on motor winding - Low price, compact size • Smart Infeed – SINAMICS S120 Smart Line Modules (SLM): - Line-commutated converters - Suitable for operation in infeed and regenerative feedback mode (four-quadrant operation) - Power semiconductors: IGBT modules - Line harmonics: total harmonic distortion factor of the line current THD(I) up to 45 % - Low voltage load on motor winding - Medium price, medium size The maximum voltage supplied to the motor by the converter in the case of SINAMICS converters (with optimized pulse pattern) is: UMotor max = 0.97 · Uline With converters of the SINAMICS G130 and SINAMICS G150 series, SINAMICS S120 Basic Line Modules, SINAMICS S120 Smart Line Modules and SINAMICS G120P, it is ensured at full line voltage (position 12 of the Article No.) that the rated motor voltages specified in this catalog are available. If an alternative converter is to be used, it must be established in the context of project engineering that the rated motor voltage can be provided by the converter. Otherwise, the motor current rises and there is a risk of excessive motor temperature which reduces the service life. Siemens D 81.8 · 04/2014 3/3 3 © Siemens AG 2014 System Components Configuring Engineering the drive system ■ Overview (continued) 3 Regulated infeed Engineering the drive system If the infeed involves a self-commutated converter (regulated infeed), the maximum available motor voltage is higher than the line voltage. The DC link voltage and, therefore, also the output voltage of the converter is normally regulated so it is independent of any fluctuations in line voltage. A motor should be selected (according to voltage, speed and torque) following engineering of the drive system to ensure that all the potentials that arise from the motor and converter combination can be exploited. The motors of the SIMOTICS FD series are specifically matched to the SINAMICS converter series. This results in additional system advantages, such as reduced noise emission. For converters of the SINAMICS S150 series that are equipped with an Active Line Module as well as SINAMICS S120 with Active Line Modules, the following applies: • Self-commutated converter • Suitable for operation in infeed and regenerative feedback mode (four-quadrant operation) • Power semiconductors: IGBT modules • Line harmonics: total harmonic distortion factor of the line current THD(I) up to 3 % • With reference to the supply network, with factory settings cosϕ = 1 • Higher voltage load on the motor winding than for unregulated infeed The maximum voltage supplied to the motor by the converter in the case of SINAMICS converters (with optimized pulse pattern) is: UMotor max = 1.11 · Uline With converters of the SINAMICS S120 series with Active Line Modules and SINAMICS S150, it is ensured that the rated motor voltages specified in this catalog are available. If an alternative converter is to be used, it must be established in the context of project engineering that the rated motor voltage can be provided by the converter. Otherwise, the motor current rises and there is a risk of excessive motor temperature which reduces the service life. 3/4 Siemens D 81.8 · 04/2014 In contrast to simple selection of a motor, drive system engineering takes into account that the converter also contributes towards loading of the motor winding due to non-sinusoidal voltage and current. In this catalog, SIMOTICS FD motors specially designed for converter-fed operation are offered for the following line voltages: • 400 V, 50 Hz • 500 V, 50 Hz • 690 V, 50 Hz • 460 V, 60 Hz • 575 V, 60 Hz Motors for other line voltages can be supplied on request. Depending on the type of infeed, it is possible to choose between motors whose rated voltages either lie below the line voltage (unregulated infeed) or above the line voltage (regulated infeed). Depending on which information is available for the drive system to be engineered, engineering can be performed in accordance with one of the two subsequent detail levels. © Siemens AG 2014 System Components Configuring Engineering the drive system ■ Overview (continued) Options for engineering the drive system Detail level 1 Detail level 2 Simple motor selection – details of the converter are not known Engineering the drive system – details of the converter are known – certain properties of the drive system can be optimized Engineering goal • Selection of a motor specifically for converter-fed operation • Selection of a motor specifically for converter-fed operation • Optimum voltage utilization (low-cost drive system without derating of converter or motor) • Low noise emissions Preconditions • Line voltage is known • Required rated speed is known • Motor will only be operated on the converter • Type of infeed, or the converter, are unknown • Line voltage is known • Required rated speed is known • Motor will only be operated on the converter • Type of infeed is known • For operation on the SINAMICS converter, the rated pulse frequency is 1.25 kHz or more. • For operation on an alternative converter, the pulse frequency is 2.5 kHz or more. Engineering tasks • Selection of the line voltage or inquiry about other line voltages (position 12 of Article No.) • Selection of a catalog version for the unregulated infeed (position 6 of the Article No.: 2 for SINAMICS converter or 4 for alternative converter) • Rated output of motor is reduced by the factor 0.85 • Selection of the line voltage or inquiry about other line voltages (position 12 of Article No.) • Selection of a catalog version for: - Unregulated infeed (position 6 of Article No.: 2 for SINAMICS converter or 4 for alternative converter) - Regulated infeed (position 6 of Article No.: 1 for SINAMICS converter or 3 for alternative converter) • The catalog data is applicable for operation on SINAMICS converter and under the described preconditions for operation on alternative converters (with the exception of sound pressure levels) Advantages of the drive system • The required rated motor voltage is available. • Irrespective of the pulse frequency, type of infeed and converter type, compliance with the thermal class specified in the catalog is assured. • The required rated motor voltage is available and will be optimally utilized. • For operation on SINAMICS converter: - Low-noise motor (LPA ≤ 79 dB(A)) - Integration in the "STARTER commissioning tool" software and the Advanced Operation Panel (AOP) of the converter - Operation of a motor with a winding system on two parallel converter motor modules is possible as standard - Recommendation of a SINAMICS converter for the respective catalog version - Optimized pulse pattern for SIMOTICS FD Constraints with unknown converter • Rated output of motor is reduced by the factor 0.85 • For operation on an alternative converter, the specified A-weighted sound pressure level is only a guide value due to the • The A-weighted sound pressure level specified cannot be used for engineering because the pulse frequency and the modulation technique unknown modulation technique. of the converter are unknown. • Operation with optimized pulse patterns is normally assumed. If operation with space-vector modulation is planned, constraints may exist with regard to the pulse frequency and operation of a motor with a winding system on a SINAMICS converter with two parallel motor modules. Siemens D 81.8 · 04/2014 3/5 3 © Siemens AG 2014 System Components Configuring Engineering the drive system ■ Overview (continued) A motor can also be selected without precise knowledge of the converter. In this case, the motor is the central focus of the engineering and not the drive system and its optimization. Simple motor selection focuses on the large majority of applications for which an unregulated infeed is sufficient and the functions of a regulated infeed (e.g. four-quadrant operation or low line harmonics) are not required. Applications in which an unregulated infeed is normally sufficient include excavators, conveyor drives, bow thrusters, wood chippers, centrifugal pumps, fans, mills, propellers, pumps or shredders. Even in applications with a quadratic torque characteristic, regulated infeed is not normally required. Engineering at detail level 2 involves, in addition to the motor selection, engineering of an optimized drive system due to knowledge of the converter – especially the infeed – with regard to: • Noise emission (for operation on SINAMICS converter) • Voltage utilization and therefore motor or converter current consumption • Output and torque or frame size M For engineering at detail level 1, the line voltage must be known. U line M Uline ; f line Urated ; Irated Urated ; Irated UDC Infeed f Pulse ; I L G_D081_EN_00455 Engineering the drive system – detail level 2 G_D081_EN_00454 3 Simple motor selection – detail level 1 Prated ; T rated ; n rated ; L PA Drive system – engineering of the drive system at detail level 2 For engineering at detail level 2, the following must be known: • Line voltage and, where applicable, line frequency • Unregulated or regulated infeed • Rated pulse frequency of the converter Prated ; Trated ; n rated Drive system – simple motor selection (detail level 1) When selecting a SIMOTICS FD motor from the catalog, it is important to note: • For all line voltages, the versions for unregulated infeed are required. • The converter must be able to provide the rated voltage of the motor. Otherwise, the motor current rises and there is a risk of excessive motor temperature which reduces the service life of the motor. • Due to the unknown infeed and modulation technique of the converter, the rated output specified in the catalog must be reduced (reduction factor 0.85). • The maximum A-weighted sound pressure levels specified in the catalog cannot be used, because the modulation technique of the converter is unknown. When selecting a SIMOTICS FD motor from the catalog, it is important to note: • For each combination of line voltage and infeed, a SIMOTICS FD motor can be selected that optimally utilizes the available converter output voltage. • For operation on SINAMICS converter (firmware 4.6), operation is already possible from the rated pulse frequency fPulse = 1.25 kHz upwards without derating. • If the converter is not a SINAMICS G130, SINAMICS G150, SINAMICS S120, SINAMICS S150 or SINAMICS G120P, the pulse frequency must be at least 2.5 kHz, otherwise the risk of excessive motor temperature rise and noise emission prevails. • The maximum A-weighted sound pressure levels specified are applicable for operation on SINAMICS G130, SINAMICS G150, SINAMICS S120, SINAMICS S150 or SINAMICS G120P converters. Rated motor voltages according to line voltage and infeed Line voltage Uline 400 V 460 V 500 V 575 V 690 V Line frequency fline 50 Hz 60 Hz 50 Hz 60 Hz 50 Hz Line voltage – position 12 of Article No. 1 5 2 6 3 Infeed Unregulated Regulated Unregulated Regulated Unregulated Regulated Unregulated Regulated Unregulated Regulated System description – position 6 of Article No. 2; 4 1; 3 2; 4 1; 3 2; 4 1; 3 2; 4 1; 3 2; 4 1; 3 Rated motor voltage Urated 380 V 425 V 440 V 480 V 480 V 520 V 550 V 610 V 660 V 730 V Insulation system IIC C 500 When the motor is selected correctly, it operates with optimized pulse patterns from approximately 87 % of the rated speed upwards. 3/6 Siemens D 81.8 · 04/2014 IIC C 690 If operation with space-vector modulation is planned, the converter pulse frequency (also in the case of SINAMICS converters) must be at least 2.5 kHz or the motor output must be reduced (see the following section for derating factors). © Siemens AG 2014 System Components Configuring Engineering the drive system ■ Overview (continued) SIMOTICS FD motor on SINAMICS converter The SIMOTICS FD motors are designed for operation with optimized pulse patterns. The optimized pulse patterns for SIMOTICS FD are only implemented when • the motor type is selected as "SIMOTICS FD" on commissioning (SINAMICS parameter p300), • the motor is operated with optimized pulse patterns (SINAMICS parameter p1802 = 19). With SINAMICS G converters, parameters are assigned automatically when the motor type is selected, and with SINAMICS S converters, they are assigned manually. • Note: with SINAMICS S converters, space-vector modulation is preset and can be changed manually depending on the application to optimized pulse patterns for SIMOTICS FD. For certain applications (e.g. multi-axis drives), it is not admissible for SINAMICS S converters to be operated with optimized pulse patterns. 3 The thermal torque limit characteristic takes into account the transition from space-vector modulation at speeds significantly below the rated speed with optimized pulse patterns at speeds of approx. 87 % of the rated speed upwards (see diagram below). For motors with a rated speed of 3600 rpm and a supply frequency of around 120 Hz, it must be noted that the rated pulse frequency of the converter has to be increased to 2.5 kHz. This can result in derating of the converter. 1.10 1.00 T/Trated 0.80 0.70 0.60 0.50 0.40 0.30 0.20 0.10 0.00 G_D081_EN_00456 Torque If the application requires that the converter is operated with optimized pulse patterns for SIMOTICS FD motors for speeds above approx. 87 % of the rated speed with space-vector modulation, the rated motor output must be reduced as follows in accordance with the rated pulse frequency of the converter: • Space-vector modulation with rated pulse frequency of 1.25 kHz: derating factor 0.85 • Space-vector modulation with rated pulse frequency of 2 kHz: derating factor 0.95 • Space-vector modulation with rated pulse frequency of 2.5 kHz: derating factor 1 Space-vector modulation 0 0.4 Optimized pulse patterns (optimized for SIMOTICS FD) 0.8 1.2 1.6 Selection of SIMOTICS FD in the STARTER commissioning tool SIMOTICS FD motor on alternative converters If a SIMOTICS FD motor is operated on an alternative converter that does not belong to the SINAMICS series G130, G150, S120, S150 or G120P, it is important to note the following: • The selection and ordering data with the exception of the A-weighted sound pressure level for operation on a SINAMICS converter also applies to operation on an alternative converter when the rated motor voltage is available and the rated pulse frequency of the converter is at least 2.5 kHz. • The A-weighted sound pressure levels specified for operation on a SINAMICS converter do not apply for operation on an alternative converter due to the unknown modulation technique. • A distinction is made between the standard version (position 5 of Article No. = 4 for series 1.M1, 1.L1, 1.P1, 1.Q1, 1.H1 and 1.N1) and the increased output version (position 5 of Article No. = 5 for series 1.P1 and 1.Q1). • A distinction is made between regulated infeed (position 6 of Article No. = 3) and unregulated infeed (position 6 of Article No. = 4). 2.0n/nrated 2.4 Speed Modulation techniques and thermal torque limit Siemens D 81.8 · 04/2014 3/7 © Siemens AG 2014 System Components Configuring Engineering the drive system ■ Overview (continued) Catalog versions Rated motor speeds 3 To select a catalog version, in addition to the available voltage (see section "Voltage supply") the required motor speed must also be known. The rated speeds of the catalog versions are assigned to the line supplies listed in this section in accordance with the line frequency. For the line voltages 400 V, 500 V and 690 V, catalog versions are available with the rated speeds • 750 rpm • 1000 rpm • 1500 rpm • 3000 rpm For the line voltages 460 V and 575 V, catalog versions are available with the rated speeds • 900 rpm • 1200 rpm • 1800 rpm • 3600 rpm Due to the converter supply, the rated motor speed does not depend on the line frequency. The rated speeds of 750 rpm to 1200 rpm are covered by the 6-pole version and the rated speeds of 1500 rpm to 3600 rpm are covered by the 4-pole version. If other rated motor speeds are required, it can be clarified on request whether it is necessary for the windings to be modified. Recommended SINAMICS converters In the catalog, a suitable converter of the SINAMICS series is assigned to every motor of the SIMOTICS FD series that is specially designed for converter-fed operation. This assignment is a recommendation. If the complete drive system is to be ordered, engineering of the drive system is required in accordance with detail level 2. Converter assignment is based on the following assumptions: • The rated motor current corresponds to the reduced baseload current IL of the converter for the standard load cycle "Minimal overloading of the converter" (see diagram below). The current IL is slightly less than the rated output current of the converter (by approx. 3 to 6 %). • The line voltage assumed on motor selection is available to the converter. • For converters with unregulated infeed, cabinet units of the SINAMICS G120P or SINAMICS G150 series are recommended. • For converters with unregulated infeed, it is assumed that no special requirements exist (e.g.: line harmonics) and infeed operation will be used exclusively (no regenerative feedback – two-quadrant operation). • For converters with regulated infeed, cabinet units of the SINAMICS S150 series are recommended. • When converters of the SINAMICS series are recommended, chassis units can also be used as an alternative. 3/8 Siemens D 81.8 · 04/2014 For the reduced base-load current IL of the overall converter, the following applies in the case of parallel connection of two power units: • For connection in parallel, the SINAMICS S150 should be replaced with SINAMICS S120 CM. For SINAMICS S120 CM in the version with parallel connection of motor modules, the reduced base-load current IL for the single device is doubled and the total current is reduced by 5 %. Converter current 10 s 1.5 x IL Short-time current 150 % Short-time current 110 % Rated current (continuous) Base load current IL for low overload 1.1 x IL Irated IL G_D213_EN_00035 Catalog versions and special versions 60 s 300 s t Definition of the standard load cycle "Minimal overloading of the converter" Due to the numerous assumptions on which the assignment of converters of the SINAMICS series is based, it must be ensured that the assumptions quoted actually apply for the planned application when the drive system is engineered. This must apply for every point, otherwise the recommendation is invalid, especially: • When the motor is to be operated with short-time or periodic overloading, and currents higher than the rated motor current are necessary. Note: not all rated motor currents fully utilize the reduced base-load current of the converter, which is why the recommended converter may already have current reserves. For evaluating existing current reserves, the rated motor current can be compared to the respective reduced base-load current of the converter (see table below). • When operation with space-vector modulation is planned, the converter is not operated with the optimized pulse patterns for SIMOTICS FD motors. In this case, the pulse frequency of the converter must be at least 2.5 kHz or the output must be reduced. • Furthermore, with unregulated infeed and operation exclusively in space-vector modulation, the motor only has a maximum voltage available to it of UMotor max. = 0.92 · Uline © Siemens AG 2014 System Components Configuring Engineering the drive system ■ Overview (continued) Reduced base-load currents IL of the SINAMICS converters (SINAMICS G120P, SINAMICS G150 and SINAMICS G130 or SINAMICS S150 and SINAMICS S120 technically comparable) – for engineering purposes, IL can be regarded as equal to the motor current Output kW Number IL of motor modules A fP Type kHz Number IL of motor modules A fP Type kHz Number IL of motor modules A fP Type kHz 3 SINAMICS G120P, SINAMICS G150 converters – unregulated infeed Urated,Motor,min/Urated,Motor,max: 380/480 V Urated,Motor,min/Urated,Motor,max: 500/600 V Urated,Motor,min/Urated,Motor,max: 660/690 V 75 – – 1 80 1.25 1SL3710-1GH28-5AA3 90 – – 1 95 1.25 1SL3710-1GH31-0AA3 110 1 200 2 6SL3710-1PE32-1AA0 1 171 1.25 6SL3710-1GF31-8AA3 1 115 1.25 1SL3710-1GH31-2AA3 132 1 240 2 6SL3710-1PE32-5AA0 1 208 1.25 6SL3710-1GF32-2AA3 1 142 1.25 1SL3710-1GH31-5AA3 160 1 290 2 6SL3710-1PE33-0AA0 1 250 1.25 6SL3710-1GF32-6AA3 1 171 1.25 1SL3710-1GH31-8AA3 200 1 360 2 6SL3710-1PE33-7AA0 1 320 1.25 6SL3710-1GF33-3AA3 1 208 1.25 1SL3710-1GH32-2AA3 250 1 450 2 6SL3710-1PE34-6AA0 1 400 1.25 6SL3710-1GF34-1AA3 1 250 1.25 1SL3710-1GH32-6AA3 315 1 570 1.25 6SL3710-1PE35-8AA0 1 452 1.25 6SL3710-1GF34-7AA3 1 320 1.25 1SL3710-1GH33-3AA3 355 – 640 2 6SL3710-1PE36-6AA0 – 400 1 710 1.25 6SL3710-1PE37-4AA0 1 560 1.25 6SL3710-1GF35-8AA3 1 400 1.25 1SL3710-1GH34-1AA3 450 1 820 1.25 6SL3710-1GE38-4AA3 – 1 452 1.25 1SL3710-1GH34-7AA3 560 1.25 1SL3710-1GH35-8AA3 – 500 – 1 710 1.25 6SL3710-1GF37-4AA3 – 560 1 960 1.25 6SL3710-1GE41-0AA3 1 790 1.25 6SL3710-1GF38-1AA3 1 630 2 1092 1.25 6SL3710-2GE41-1AA3 2 836 1.25 6SL3710-2GF38-6AA3 – 710 2 1340 1.25 6SL3710-2GE41-4AA3 2 1036 1.25 6SL3710-2GF41-1AA3 1 710 1.25 1SL3710-1GH37-4AA3 800 – – 1 790 1.25 1SL3710-1GH38-1AA3 900 2 1516 1.25 6SL3710-2GE41-6AA3 – – 1000 – 2 1314 1.25 6SL3710-2GF41-4AA3 2 1120 – – – 1200 – – – 1036 1.25 6SL3710-2GH41-1AA3 SINAMICS G120P, SINAMICS G150 converters – regulated infeed Urated,Motor,min/Urated,Motor,max: 380/480 V Urated,Motor,min/Urated,Motor,max: 500/730 V 75 – 1 80 1.25 6SL3710-7LG28-5AA3 90 – 1 95 1.25 6SL3710-7LG31-0AA3 110 1 205 2 6SL3710-7LE32-1AA3 1 115 1.25 6SL3710-7LG31-2AA3 132 1 250 2 6SL3710-7LE32-6AA3 1 142 1.25 6SL3710-7LG31-5AA3 160 1 302 2 6SL3710-7LE33-1AA3 1 170 1.25 6SL3710-7LG31-8AA3 200 1 370 2 6SL3710-7LE33-8AA3 1 208 1.25 6SL3710-7LG32-2AA3 250 1 477 2 6SL3710-7LE35-0AA3 1 250 1.25 6SL3710-7LG32-6AA3 315 1 590 1.25 6SL3710-7LE36-1AA3 1 320 1.25 6SL3710-7LG33-3AA3 355 – 400 1 725 1.25 6SL3710-7LE37-5AA3 1 400 1.25 6SL3710-7LG34-1AA3 450 1 820 1.25 6SL3710-7LE38-4AA3 1 452 1.25 6SL3710-7LG34-7AA3 500 – 560 1.25 6SL3710-7LG35-8AA3 1.25 6SL3710-7LG37-4AA3 560 – – 960 1.25 6SL3710-7LE41-0AA3 1 630 – – 710 1 1230 1.25 6SL3710-7LE41-2AA3 1 710 800 1 1370 1.25 6SL3710-7LE41-4AA3 1 790 1.25 6SL3710-7LG38-1AA3 900 – 1 880 1.25 6SL3710-7LG38-8AA3 1000 – 1 1000 1.25 6SL3710-7LG41-0AA3 1120 – – 1200 – 1 1230 1.25 6SL3710-7LG41-3AA3 More information about SINAMICS converters can be found in the SINAMICS Engineering Manual. Siemens D 81.8 · 04/2014 3/9 © Siemens AG 2014 System Components Configuring Engineering the drive system ■ Overview (continued) Case 1 can be described with the Article No. without an additional order code. For case 2 and case 3, the appropriate order codes and plain text details are required. • Non-standard line voltage (position 12 of Article No.: 9): Order code M1Y and non-standard line voltage and/or rated motor voltage specified in plain text • Non-standard rated speed (position 13 of Article No.: 9): Order code N1Y and non-standard rated speed specified in plain text L PA, rated Constant flow range Rated range nrated Field-weakening range Speed Non-standard motor and load data possible on request. The variants of the SIMOTICS FD motor series that can be selected in the catalog have been designed such that the maximum A-weighted sound pressure levels listed in the tables below are not exceeded in no-load operation at the rated operating point when connected to a SINAMICS converter. This has been achieved thanks to the following measures: • Optimized electrical design: reduced, electromagnetic noise generation • Optimized mechanical design: improved radiation characteristics • The choice of rated voltages, whereby the maximum converter output voltages supplied are optimally utilized • Operation of the SINAMICS converter with an optimized pulse pattern: reduced electromagnetically generated noise, especially in the range of the rated speed ("rated range" in the diagrams below). • Choice of suitable built-in fan (for 1LM1 and 1LL1): limiting of the aerodynamic noise • Dimensioning of new separately driven fan: limiting of the noise from the separately driven fan Motors of the SIMOTICS FD series can be selected in the "STARTER commissioning tool" software and in the Advanced Operation Panel (AOP) as a motor type. This ensures that operation using the named modulation technique is assured for all SIMOTICS FD motors in the respective range close to the rated speed. A-weighted sound pressure levels under no-load operation on SINAMICS converter at rated speed (tolerance +3 dB SIMOTICS FD series LPA in dB(A) 1LM1, 1LL1, 1LN1 79 1LQ1, 1LP1 (position 5 of Article No. = 2) (position 5 of Article No. = 3) 79 85 1LH1 78 3/10 Siemens D 81.8 · 04/2014 Schematic diagram of sound pressure level (1LM1, 1LL1) L PA, rated Constant flow range Rated range nrated Field-weakening range G_D081_EN_00458 Noise emission for operation on SINAMICS converter Sound pressure level 3 For versions of the SIMOTICS FD series that are not listed in the catalog, individual inquiries regarding winding modification are necessary. A winding modification may be required for: 1. A combination of defined supply and rated speed codes that are not listed in the catalog. 2. Non-standard supply systems for which a code has not been defined. 3. Non-standard rated speeds for which a code has not been defined. G_D081_EN_00457 Modified windings – Special versions for non-standard voltage or speed For engineering a noise-optimized system, it is therefore important to: • Select a motor with a rated voltage that matches the line voltage and the infeed of the SINAMICS converter. • Select a motor with a rated speed that is lower than or equal to the speed(s) to be expected during operation. • Upgrade the hardware and software of the SINAMICS converter if an existing SINAMICS converter (position 16 of the SINAMICS Article No. 0, 1 or 2) is to be used. Sound pressure level Special versions Speed Schematic diagram of sound pressure level (1LP1, 1LQ1, 1LH1, 1LN1) The noise emission was able to be reduced in particular close to the rated speed (rated range). If a constant torque drive (mainly 1LP1, 1LQ1, 1LH1 and 1LN1) is implemented for low noise generation, it must be ensured during engineering that the lower operating speeds remain within the rated range. This can be achieved, for example, through the correct choice of rated speed. In self-ventilated motors (1LM1, 1LL1), the aerodynamic noise generated by the built-in fan dominates with increasing speed above the rated range. For drives of this type, the high operating speeds must be close to the rated speed. EMC The system comprising SIMOTICS FD in combination with SINAMICS has been checked according to the guidelines for electromagnetic compatibility 2004/108/EC and the regulations of the EMC directives. System compatibility is only provided with EMC-compliant grounding and if shielded power cables are used whose shield is conductively bonded over a large area to the metal motor terminal box. © Siemens AG 2014 System Components Configuring Water cooling (1LH1 and 1LN1 motors) ■ Overview Cooling circuit in the application Cooling water quality When water-cooled motors of the SIMOTICS FD series (1LH1, 1LN1) are operated in the application, they become part of the overall cooling circuit. Apart from the cooling unit, this can include other heat sources. The water-cooled versions of the SIMOTICS FD series offer solutions for different qualities of cooling water. The optimum cooling water quality can therefore be selected in accordance with the location and application. The following tables contain the water properties defined for the various motor versions. The construction of the cooling materials demands two completely different cooling concepts for the overall cooling circuit in the application. For the coolant circuit in SIMOTICS FD motors of the 1LH1 and 1LN1 series, the materials listed in the table "Materials used in the motor (cooling circuit)" can be deployed which provides the user with a range of possibilities for constructing the cooling circuit. Definition of water properties Water quality Potable water Fresh water Sea water 6.5 to 8.0 6.0 to 9.5 6.5 to 10 – < 0.9 pH value – Carbon-related hardness mMol/l – Total hardness mMol/l < 2.5 < 1.7 < 1.8 Chloride ions (Cl-) mg/l < 200 < 3000 Sulfate ions (SO42-) mg/l < 50 < 240 < 3000 Sulfide ions (S2-) mg/l – – <1 Please read the following definitions for clarification: Nitrate ions (NO3+) mg/l < 50 < 50 < 50 1. Closed cooling circuit: The pressure compensator is closed (no ingress of oxygen) and fitted with a pressure-relief valve (6 bar for 1LN1 motors, 3 bar for 1LH1 motors); it is always connected on the suction side of the pump. The coolant is only routed through the SIMOTICS FD motors, the components required for cooling and, if necessary, a converter. The materials used in the cooling circuit comply with the recommendations in the table "Admissible materials for the overall cooling circuit". Iron (Fe3+) mg/l – – <1 Ferromanganese ions mg/l (Fe3+Mn2+) – – < 50 Ammoniac (NH3) Ammonium (NH4+) mg/l – – < 15 Alkalinity mg/l < 300 – – Dissolved substances mg/l < 340 < 340 < 340 Electrical conductivity µS/cm < 500 < 2000 < 32000 2. Semi-open cooling circuit: Oxygen can only enter the coolant through the pressure compensator, otherwise the cooling circuit corresponds to a closed cooling circuit. Size of entrained particles (sand) mm < 0.1 < 0.1 < 0.1 Biological growth resistant No No Yes The electrochemical processes that take place in a cooling system must be minimized by choosing the right materials. For this reason, mixed installations, i.e. a combination of different materials, such as copper, brass, iron, zinc, or halogenated plastic (PVC hoses and seals), should not be used or should be limited to the absolutely essential minimum. 3. Open cooling circuit: The coolant is guided through the motors and the cooling components required for heat dissipation as well as through components external to the cooling circuit. The materials used comply with the minimum requirements specified in the table "Admissible materials for the overall cooling circuit". < 50 Assignment of motor versions to cooling water quality Water quality to motor cooling Motor type 1LH1 1LN1 Potable water ✓ ✓ Possible cooling circuits of the SIMOTICS FD motor series Fresh water ✓ 1) ✓ Type Sea water – ✓ Type of cooling circuit Closed Semi-open Open Materials used in the motor cooling circuit 1LH1 ✓ – – 1LN1 ✓ ✓ – Motors of the 1LH1 series are equipped with built-in cooling pipes constructed from copper as standard, or as an option from stainless steel (order code M85). For further information on the construction of a cooling circuit, see the Manual "SINAMICS S120 – Chassis Liquid Cooled Power Units". Motors of the 1LN1 series are equipped with a double-walled air-to-water heat exchanger. The materials used in the 1LH1 and 1LN1 series are listed in the table below. Materials used in the motor (cooling circuit) 1) Motor type Materials 1LH1 (standard) Cu, stainless steel (V2A), CuZn39Pb3 1LN1 (standard) CuNi (90/10) RILSAN® plastic-coated steel With order code M85. Siemens D 81.8 · 04/2014 3/11 3 © Siemens AG 2014 System Components Configuring Water cooling (1LH1 and 1LN1 motors) ■ Overview 3 Admissible materials for the overall cooling circuit Inhibitors, anti-freeze, biocides Material Coolant additives 1LH1 1LH1 with order code M85, 1LN1 Comment Aluminum – ✓ Zinc ✓ ✓ Can be used in closed circuits with inhibitor. Brass ✓ ✓ Can be used in closed circuits with inhibitor. Copper ✓ ✓ Can be used in closed circuits with inhibitor. Common steel (e.g. St 37) ✓ ✓ Permissible in closed circuits with inhibitors or anti-freeze, check for oxide formation, inspection window recommended. Cast steel/ cast-iron ✓ ✓ High-alloy steel, Group 1 (V2A) ✓ ✓ High-alloy steel, Group 1 (V2A) ✓ ✓ PVC – – Hoses ✓ ✓ Reduce use to a minimum. Must not be used as the main pipe for the whole system. Effectiveness regarding the growth of microorganisms. 3/12 Siemens D 81.8 · 04/2014 1LH1 1LH1 with order code M85 1LN1 Inhibitor without anti-freeze effect Required NALCO TRAC100 0.2 % < X ≤ 0.25 % Not required Not required Anti-freeze Antifrogen N 20 % < X ≤ 45 % Antifrogen L 25 % < X ≤ 48 % Varidos FSK 25 % < X ≤ 45 % Antifrogen N 20 % < X ≤ 45 % Antifrogen L 25 % < X ≤ 48 % Varidos FSK 25 % < X ≤ 45 % Biocide 1) Yes Antifrogen N, minimum quantity 20 % Antifrogen L, minimum quantity 30 % Varidos FSK, minimum quantity 30 % Not required Anti-freeze + biocide When Antifrogen N > 20 % or Antifrogen L/ Varidos FSK > 30 % is used, an adequate biocidal effect exists. Closed circuit and use of strainers and flushback filters. ✓ Admissible – Inadmissible 1) Material © Siemens AG 2014 System Components Condition monitoring system SIPLUS CMS condition monitoring systems for the continuous condition monitoring of motors ■ Overview The SIPLUS CMS condition monitoring systems continuously monitor the condition of wear-prone drive components such as motors. Depending on the system, individual motors can be monitored as well as complete drive trains, or even the entire plant. IEPE sensors are used for acquisition of the motor vibrations for analysis, visualization and archiving by SIPLUS CMS. Information is supplied regularly and event-driven – also under remote operation. SIPLUS CMS can also be retrofitted. 3 More information on SIPLUS CMS is available on the Internet at: www.siemens.com/siplus-cms SIPLUS CMS X-Tools for further analysis Remote access e. g. via cRSP/ePS SCADA e. g. via WinCC, PCS7, Maintenance Station SIMATIC IPC SP01_00026 Ethernet SIPLUS CMS2000 Configuration: 1 Basic Unit VIB 1 VIB-MUX 2 temperature modules Binary signals LAN SIMATIC controller Up to 16 IEPE vibration sensors for modular connection Additional monitoring: • Speed • Temperature measurement (Pt100, Pt1000, ...) • e. g. pressure sensors via analog inputs Drive train: Drive Gear Bearing Pump Siemens D 81.8 · 04/2014 3/13 © Siemens AG 2014 System Components Couplings Siemens Integrated Drive Systems ■ Overview Integrated drive portfolio: 3 The core elements of a fully integrated drive system are frequency converters, motors, couplings and gear units. Siemens offers all the required components in top manufacturing quality from a single source, perfectly integrated – operating perfectly together, for all performance classes. As a standard solution or tailored to individual requirements. No other provider on the market is able to offer a comparable portfolio. All Siemens drive components are optimally tuned to each other so that they interact ideally in every application. Because of the environment, the coupling has to meet a large number of additional requirements. Couplings must be as suitable for use in a potentially explosive environment as for use at a high or low ambient temperature. The environment may be defined as chemically aggressive or be subject to laboratory conditions or requirements of food manufacture. Standard construction types of Siemens FLENDER couplings for SIMOTICS FD motors Type Description N-EUPEX Flexible cam coupling • Universally implementable coupling for compensation of shaft misalignment • Suitable for plug-in installation and easy assembly with three-part design Rated torque: 19 … 62000 Nm RUPEX Flexible pin and bush coupling • Fail-safe, universal coupling for medium to very high torques with a good misalignment range • Compact design, low weights and mass moments of inertia • Suitable for plug-in assembly Rated torque: 200 … 1300000 Nm ZAPEX Gear couplings • Double-jointed coupling compensates for angular, parallel and axial misalignment • Long-term lubrication through design measures and the use of special seals • Small dimensions • Can be used for high shock loads Rated torque: 1300 … 7200000 Nm ARPEX All-steel couplings • Zero-backlash, torsionally rigid coupling • For compensating radial, angular, and axial shaft misalignment by means of two flexible lamella packages made of stainless spring steel • Easy assembly thanks to compact lamella packages Rated torque: 92 … 1450000 Nm Siemens Integrated Drive Systems turn simple drive components into real systems. Drive technology based on IDS ensures maximum productivity, energy efficiency and reliability in every automation environment and over the entire product lifecycle. FLENDER couplings – Part of the drive system A drive system comprises individual machines, including the motor and gear unit. Couplings combine these components and frequently also establish the connection to the driven machine. The coupling can perform other tasks in addition to the transmission of rotary motion and torque, such as: • Compensation for shaft misalignment with low restorative forces • Influencing of intrinsic torsional frequency and damping • Overload: interruption or limitation of torque • Electrical insulation, noise insulation • Function in explosive environments Couplings are frequently planned after the machines to be connected have already been selected. Thanks to a large number of different coupling assembly options, specified boundary conditions for installation space and connection geometry can be met from the catalog standard. The coupling also performs secondary functions, such as the provision of the brake disk or brake drum for operational or holding brakes, devices to record speed or the addition of chain wheels or belt pulleys. 3/14 Siemens D 81.8 · 04/2014 © Siemens AG 2014 System Components Couplings Siemens Integrated Drive Systems ■ Overview (continued) Shaft misalignment Shaft misalignment is the result of displacement that occurs during assembly and operation and, where machines constructed with two radial bearings each rigidly coupled, will cause high loads being placed on the bearings. Elastic deformation of base frame, foundation and machine housing will lead to shaft misalignment which cannot be prevented, even by precise alignment. Furthermore, because individual components of the drive train heat up differently during operation, heat expansion of the machine housings causes shaft misalignment. Poorly aligned drives are often the cause of seal, rolling bearing or coupling failure. Alignment should be carried out carefully by specialist personnel in accordance with the Siemens operating instructions. 3 Kr Depending on the direction of the effective shaft misalignment, a distinction is made between: Kw Ka G_MD10_XX_00004 G_MD10_XX_00002 G_MD10_XX_00003 Radial misalignment Angular misalignment • Two-joint couplings – ARPEX and ZAPEX series Two-joint couplings are always designed with an adapter. The two joint levels are able to absorb axial and angular misalignment. Radial misalignment occurs via the gap between the two joint levels and the angular displacement of the joint levels. The permitted angular misalignment per joint level is frequently about 0.5°. The permitted shaft misalignment of the coupling can be adjusted via the length of the adapter. If there are more than two joint levels, it is not possible to define the position of the coupling parts relative to the axis of rotation. (The less frequently used parallel-crank couplings are an exception). Kr G_MD10_XX_00014 The couplings can be subdivided into the following groups: • Single-joint couplings – N-EUPEX and RUPEX series Couplings with flexible elements mainly made of elastomer materials. Shaft misalignment results in deformation of the elastomer elements. The elastomer elements can absorb shaft misalignment as deformations in an axial, radial and angular direction. The degree of permissible misalignment depends on the coupling size, the speed of rotation and the type of elastomer element. Single-joint couplings do not require an adapter and are therefore short versions. Kr Axial misalignment G_MD10_XX_00005 Example: RUPEX coupling Example: ARPEX coupling Siemens D 81.8 · 04/2014 3/15 © Siemens AG 2014 System Components Couplings Siemens Integrated Drive Systems ■ Overview (continued) Overload 3 Overload conditions are operating conditions that go beyond the limit loads of the coupling. Overload conditions may occur under non-standard operating conditions, e.g. drive blockage, short circuit or supply fluctuations, as well as under standard operating conditions, e.g. when starting or braking. Particularly in the case of high mass moments of inertia of the driven machine, torques that are a multiple of the motor starting torque may become effective during direct starting or star-delta starting. Overload conditions may damage not only the coupling but also the entire drive train. Overload conditions can frequently be prevented with special design measures. SIRIUS soft starters or SINAMICS frequency converters are suitable for considerably reducing starting torques of induction motors. If drive blockages or overloads of the driven machine cannot be ruled out, torque limiting SECUREX couplings can prevent damage to the drive train. Coupling behavior under overload conditions Coupling behavior under overload where the torque is considerably above the limits of use of the coupling concerned is determined by the engineering design of the coupling series. The ZAPEX, ARPEX, N-EUPEX and RUPEX coupling series can withstand overloads until the breakage of metal parts. These coupling series are designated as fail-safe. Coupling types which can withstand overload, i.e. fail-safe types, are used e.g. in crane systems. In case of coupling breakage due to overloads, the splintering metal parts may cause injury to persons and property damage! The N-EUPEX DS coupling series throws overload. The elastomer element of these couplings is irreparably damaged without damage to metal parts when subjected to excessive overload. These coupling series are designated as non-fail-safe. The types that fail can be fitted with a fail-safe device. This component enables emergency operation, even after the rubber element of the coupling has been irreparably damaged. Damping On drives which are prone to torsional and bending vibrations, measurements or calculations such as natural frequency calculations, torsional vibration simulation or bending vibration calculations are necessary for verifying safe dimensioning of the drive train and preventing damage. The drive train may, depending on complexity, be regarded as a two-mass vibration-generating system or N-mass vibration-generating system. The vibration-generating masses are defined by the rotating bodies and the couplings by the coupling stiffnesses and shaft stiffnesses. The effect of torsional vibration excitations on the behavior of the system is calculated. Torsional vibration excitations may occur during the starting of an induction motor, during a motor short circuit or in diesel engine drives. Bending vibrations may be critical if the coupling is insufficiently balanced and/or at an operating speed close to the critical speed. The details needed for calculating the torsional vibration are specified in the coupling catalog: • Dynamic torsional stiffness • Damping (specification of the damping coefficient ψ or Lehr's damping D = ψ/4π) • Mass moment of inertia of the coupling halves Electrical insulation A particularly efficient and economical measure for reducing bearing currents is to use an electrically isolating coupling. The range of couplings comprises suitable couplings in leakage-current-isolated versions for the various drive scenarios. Version for potentially explosive atmospheres Wherever a potentially explosive environment cannot be ruled out, the machinery used must meet special conditions in order to prevent the outbreak of fire as far as possible. Within the European Union, Directive 94/9/EC applies to these applications. This directive, also called ATEX 95, harmonizes the individual states' legal requirements for explosion prevention and clearly defines the procedure for testing and circulating machines and parts. Whether or not a machine is used in a potentially explosive environment, the manufacturer is required under EC Machinery Directive 98/37/EC to assess and as far as possible prevent hazards which may arise from his product. The operator has an obligation to ascertain whether an environment is potentially explosive. Details of this are laid down in Directive 1999/92/EC, also known as ATEX 137. The manufacturer is responsible for ensuring that the product is safe as defined in the EC Machinery Directive and conforms to Directive 94/9/EC if the EX requirement is specified by the operator. The drive train mostly comprises individual pieces of equipment which are put together to form a subassembly. If the individual pieces of equipment, such as motor, coupling, gear unit or driven machine, conform to Directive 94/9/EC, the manufacturer of the overall unit can limit the risk assessment to the additional hazards which arise from the combination of different individual pieces of equipment. The hazards which can arise from the individual pieces of equipment are assessed by the relevant suppliers. The coupling series suitable for use in potentially explosive environments are marked EX in Catalog MD 10.1. FLENDER couplings are to be rated as components according to the new EC Machinery Directive 2006/42/EC. Therefore, Siemens does not issue a declaration of incorporation for these products. 3/16 Siemens D 81.8 · 04/2014 © Siemens AG 2014 System Components Couplings Siemens Integrated Drive Systems ■ Overview (continued) Assignment of coupling types to SIMOTICS FD motors Motors Air-cooled – enclosed version Water-cooled Air-cooled – open version Self-ventilation Forced-air cooling Water-jacket cooling Heat exchanger Self-ventilation Forced-air cooling Cooling method IC411 Cooling method IC416 Cooling method IC71W Cooling method IC86W Cooling method IC01 Cooling method IC06 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 Conveyor belts, paper machines, rolling mills Extruders, rolls, winders Propeller drives, bow thrusters Compressors, fans Lifting, holding, closing gear Paper, steel, mining, cement Marine, plastics, textile, paper, steel Marine, steel, plastics Energy, steel Cranes RUPEX ARPEX ZAPEX ARPEX ZAPEX ARPEX ZAPEX RUPEX ARPEX RUPEX 3 Applications Pumps, fans, compressors Industry assignments W&WW, energy, chemicals, O&G Coupling assignments N-EUPEX RUPEX ARPEX For further information on FLENDER couplings, see Catalog MD 10.1. Siemens D 81.8 · 04/2014 3/17 © Siemens AG 2014 System Components Couplings Notes 3 3/18 Siemens D 81.8 · 04/2014 4 © Siemens AG 2014 Self-ventilated motors – enclosed version 4/2 4/2 4/2 4/4 4/6 4/6 4/8 4/10 4/10 4/12 4/14 4/14 4/16 4/18 4/18 4/20 1LM1/1MM1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency Premium Efficiency Line voltage 500 V, 50 Hz High Efficiency Premium Efficiency Line voltage 690 V, 50 Hz High Efficiency Premium Efficiency Line voltage 460 V, 60 Hz High Efficiency Premium Efficiency Line voltage 575 V, 60 Hz High Efficiency Premium Efficiency 4/22 4/22 4/23 4/24 Dimensions 1LM1/1MM1 motors Flanges Terminal boxes Siemens D 81.8 · 04/2014 © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency ■ Selection and ordering data 4 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LM1/1MM1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V 3000 rpm, 4-pole 245 329 315 Δ 100.6 780 95.4 96.0 95.8 0.89 390 6.4 2.2 1■M1212-3AB11-1■■■ 1■M1212-3AB31-1■■■ 300 402 315 Δ 100.6 955 95.8 96.3 96.1 0.90 470 7.1 2.4 335 449 315 Δ 100.6 1066 95.8 96.3 95.9 0.90 530 7.5 2.5 1■M1212-3AB51-1■■■ 385 516 315 Δ 100.5 1226 96.0 96.5 96.1 0.90 600 8.1 2.7 1■M1212-3AB71-1■■■ 1■M1212-3BB51-1■■■ 435 583 355 Δ 100.5 1385 95.8 96.3 95.9 0.89 690 6.8 2.4 455 610 355 Δ 100.6 1449 95.8 96.4 96.1 0.89 720 6.1 2.2 1■M1212-3BB71-1■■■ 1500 rpm, 4-pole 245 329 315 Δ 50.5 1560 94.4 95.3 95.3 0.87 400 7.1 2.6 1■M1212-3AB11-2■■■ 315 422 315 Δ 50.5 2006 95.0 95.7 95.7 0.87 510 8.1 3.0 1■M1212-3AB31-2■■■ 345 463 315 Δ 50.5 2197 95.0 95.8 95.8 0.89 550 8.4 3.0 1■M1212-3AB51-2■■■ 395 530 315 Δ 50.5 2515 95.2 96.0 96.0 0.90 620 8.4 2.9 1■M1212-3AB71-2■■■ 450 603 355 Δ 50.5 2865 95.1 95.9 95.9 0.89 720 7.1 2.7 1■M1212-3BB51-2■■■ 500 671 355 Δ 50.4 3184 95.3 96.1 96.0 0.88 800 7.9 3.0 1■M1212-3BB71-2■■■ 1000 rpm, 6-pole 190 255 315 Δ 50.4 1815 94.7 95.5 95.4 0.79 340 8.4 2.7 1■M1212-3AC11-3■■■ 235 315 315 Δ 50.4 2245 94.9 95.7 95.7 0.81 410 8.5 2.7 1■M1212-3AC31-3■■■ 270 362 315 Δ 50.4 2579 95.1 95.7 95.8 0.83 460 8.4 2.6 1■M1212-3AC51-3■■■ 1■M1212-3AC71-3■■■ 295 396 315 Δ 50.4 2818 95.2 95.7 95.9 0.82 520 8.9 2.6 355 476 355 Δ 50.3 3391 95.0 95.7 95.5 0.85 590 9.7 2.9 1■M1212-3BC51-3■■■ 395 530 355 Δ 50.3 3772 95.2 95.9 95.5 0.83 670 10.9 2.6 1■M1212-3BC71-3■■■ 750 rpm, 6-pole 145 194 315 Δ 37.9 1847 93.9 94.8 94.8 0.77 270 8.2 2.9 1■M1212-3AC11-4■■■ 185 248 315 Δ 37.9 2356 94.2 95.1 95.2 0.80 330 8.2 2.8 1■M1212-3AC31-4■■■ 210 282 315 Δ 37.9 2675 94.3 95.3 95.4 0.83 360 7.9 2.6 1■M1212-3AC51-4■■■ 235 315 315 Δ 37.9 2994 94.4 95.4 95.5 0.83 405 7.8 2.5 1■M1212-3AC71-4■■■ 265 355 355 Δ 37.8 3376 94.3 95.3 95.3 0.86 440 9.0 2.9 1■M1212-3BC51-4■■■ 300 402 355 Δ 37.8 3821 94.5 95.4 95.4 0.86 495 9.2 2.6 1■M1212-3BC71-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G120P, SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V 3000 rpm, 4-pole 235 315 315 Δ 100.6 748 95.4 96.0 95.7 0.88 425 6.5 2.2 1■M1222-3AB11-1■■■ 1■M1222-3AB31-1■■■ 300 402 315 Δ 100.6 955 95.8 96.4 96.1 0.90 530 7.4 2.5 325 436 315 Δ 100.5 1035 95.9 96.3 95.9 0.90 570 8.5 2.8 1■M1222-3AB51-1■■■ 350 469 315 Δ 100.6 1114 95.8 96.3 96.1 0.91 610 7.0 2.3 1■M1222-3AB71-1■■■ 420 563 355 Δ 100.4 1337 95.8 96.2 95.7 0.88 750 8.1 2.9 1■M1222-3BB51-1■■■ 445 597 355 Δ 100.5 1417 95.8 96.4 96.0 0.89 790 7.2 2.6 1■M1222-3BB71-1■■■ 1500 rpm, 4-pole 250 335 315 Δ 50.5 1592 94.6 95.4 95.3 0.85 470 7.6 2.9 1■M1222-3AB11-2■■■ 315 422 315 Δ 50.5 2005 94.9 95.7 95.7 0.88 570 8.0 2.9 1■M1222-3AB31-2■■■ 345 463 315 Δ 50.5 2197 95.1 95.8 95.8 0.88 620 8.5 3.1 1■M1222-3AB51-2■■■ 400 536 315 Δ 50.5 2547 95.2 96.0 96.0 0.89 710 8.6 2.9 1■M1222-3AB71-2■■■ 455 610 355 Δ 50.4 2897 95.1 95.9 95.9 0.88 820 7.3 2.8 1■M1222-3BB51-2■■■ 510 684 355 Δ 50.4 3247 95.4 96.2 96.0 0.87 930 8.3 3.0 1■M1222-3BB71-2■■■ 1000 rpm, 6-pole 190 255 315 Δ 50.4 1815 94.7 95.5 95.4 0.80 380 8.1 2.6 1■M1222-3AC11-3■■■ 235 315 315 Δ 50.4 2245 95.0 95.7 95.7 0.81 460 8.6 2.8 1■M1222-3AC31-3■■■ 270 362 315 Δ 50.4 2579 95.1 95.7 95.8 0.82 520 8.7 2.8 1■M1222-3AC51-3■■■ 1■M1222-3AC71-3■■■ 300 402 315 Δ 50.4 2865 95.2 95.7 96.0 0.84 570 8.4 2.6 355 476 355 Δ 50.3 3391 95.1 95.7 95.5 0.83 680 10.4 2.9 1■M1222-3BC51-3■■■ 390 523 355 Δ 50.3 3725 95.2 95.9 95.6 0.84 740 10.4 2.7 1■M1222-3BC71-3■■■ 750 rpm, 6-pole 150 201 315 Δ 37.9 1910 94.1 95.0 94.9 0.77 310 8.2 2.9 1■M1222-3AC11-4■■■ 180 241 315 Δ 37.9 2292 94.3 95.2 95.1 0.77 375 8.6 3.1 1■M1222-3AC31-4■■■ 210 282 315 Δ 37.9 2675 94.4 95.3 95.3 0.81 415 8.3 2.8 1■M1222-3AC51-4■■■ 230 308 315 Δ 37.9 2930 94.4 95.4 95.5 0.83 440 8.0 2.5 1■M1222-3AC71-4■■■ 270 362 355 Δ 37.9 3439 94.3 95.3 95.3 0.86 500 8.8 2.9 1■M1222-3BC51-4■■■ 300 402 355 Δ 37.8 3821 94.5 95.4 95.4 0.86 560 9.3 2.6 1■M1222-3BC71-4■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC71-4■■■ Prated 4/2 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.M1212-3AB11-1... 1.M1212-3AB31-1... 1.M1212-3AB51-1... 1.M1212-3AB71-1... 1.M1212-3BB51-1... 1.M1212-3BB71-1... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 477 477 590 725 725 725 1.M1212-3AB11-2... 1.M1212-3AB31-2... 1.M1212-3AB51-2... 1.M1212-3AB71-2... 1.M1212-3BB51-2... 1.M1212-3BB71-2... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 477 590 590 725 725 820 1.M1212-3AC11-3... 1.M1212-3AC31-3... 1.M1212-3AC51-3... 1.M1212-3AC71-3... 1.M1212-3BC51-3... 1.M1212-3BC71-3... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-7LE33-8AA3 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 370 477 477 590 590 725 1.M1212-3AC11-4... 1.M1212-3AC31-4... 1.M1212-3AC51-4... 1.M1212-3AC71-4... 1.M1212-3BC51-4... 1.M1212-3BC71-4... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LE33-1AA3 6SL3710-7LE33-8AA3 6SL3710-7LE33-8AA3 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 302 370 370 477 477 590 1.M1222-3AB11-1... 1.M1222-3AB31-1... 1.M1222-3AB51-1... 1.M1222-3AB71-1... 1.M1222-3BB51-1... 1.M1222-3BB71-1... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1PE34-6AA0 6SL3710-1PE35-8AA0 6SL3710-1PE35-8AA0 6SL3710-1PE36-6AA0 6SL3710-1GE38-4AA3 6SL3710-1GE38-4AA3 450 570 570 640 820 820 1.M1222-3AB11-2... 1.M1222-3AB31-2... 1.M1222-3AB51-2... 1.M1222-3AB71-2... 1.M1222-3BB51-2... 1.M1222-3BB71-2... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1PE35-8AA0 6SL3710-1PE35-8AA0 6SL3370-1PE36-6AA0 6SL3710-1PE37-4AA0 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 570 570 640 710 820 960 1.M1222-3AC11-3... 1.M1222-3AC31-3... 1.M1222-3AC51-3... 1.M1222-3AC71-3... 1.M1222-3BC51-3... 1.M1222-3BC71-3... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1PE34-6AA0 6SL3710-1PE35-8AA0 6SL3710-1PE35-8AA0 6SL3710-1PE35-8AA0 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 450 570 570 570 725 820 1.M1222-3AC11-4... 1.M1222-3AC31-4... 1.M1222-3AC51-4... 1.M1222-3AC71-4... 1.M1222-3BC51-4... 1.M1222-3BC71-4... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1PE33-7AA0 6SL3710-1PE34-6AA0 6SL3710-1PE34-6AA0 6SL3710-1PE34-6AA0 6SL3710-1PE35-8AA0 6SL3710-1PE35-8AA0 360 450 450 450 570 570 Siemens D 81.8 · 04/2014 4 4/3 © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 400 V, 50 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LM1/1MM1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V 1500 rpm, 4-pole 4 175 235 315 Δ 50.4 1114 95.2 95.9 95.7 0.83 300 9.5 3.7 1■M1213-3AB11-2■■■ 255 342 315 Δ 50.4 1625 95.5 96.2 96.1 0.85 425 9.7 3.7 1■M1213-3AB31-2■■■ 320 429 315 Δ 50.4 2038 95.2 96.0 95.9 0.88 510 9.1 3.2 1■M1213-3AB51-2■■■ 410 550 315 Δ 50.5 2610 95.2 96.0 96.1 0.90 640 8.2 2.8 1■M1213-3AB71-2■■■ 465 624 355 Δ 50.5 2961 95.2 96.1 96.2 0.89 740 6.9 2.6 1■M1213-3BB51-2■■■ 510 684 355 Δ 50.4 3247 95.5 96.3 96.3 0.88 820 7.7 3.0 1■M1213-3BB71-2■■■ 1000 rpm, 6-pole 185 248 315 Δ 50.4 1767 94.8 95.7 95.6 0.79 330 8.6 2.8 1■M1213-3AC11-3■■■ 240 322 315 Δ 50.4 2293 95.0 95.9 95.9 0.81 420 8.2 2.7 1■M1213-3AC31-3■■■ 275 369 315 Δ 50.4 2627 95.1 96.0 96.0 0.83 470 8.1 2.6 1■M1213-3AC51-3■■■ 305 409 315 Δ 50.4 2913 95.3 96.1 96.1 0.82 530 8.7 2.5 1■M1213-3AC71-3■■■ 380 510 355 Δ 50.4 3630 95.2 96.1 96.1 0.85 630 9.1 2.7 1■M1213-3BC51-3■■■ 420 563 355 Δ 50.3 4011 95.5 96.3 96.1 0.82 720 10.1 2.5 1■M1213-3BC71-3■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G120P, SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V 1500 rpm, 4-pole 185 248 315 Δ 50.4 1179 95.3 95.9 95.7 0.81 360 9.9 3.9 1■M1223-3AB11-2■■■ 255 342 315 Δ 50.4 1623 95.5 96.2 96.1 0.85 475 9.6 3.6 1■M1223-3AB31-2■■■ 335 449 315 Δ 50.5 2133 95.2 96.0 96.0 0.88 600 8.7 3.1 1■M1223-3AB51-2■■■ 405 543 315 Δ 50.5 2579 95.2 96.1 96.1 0.89 720 8.5 2.9 1■M1223-3AB71-2■■■ 470 630 355 Δ 50.5 2993 95.2 96.1 96.2 0.88 840 7.1 2.7 1■M1223-3BB51-2■■■ 530 711 355 Δ 50.4 3375 95.6 96.4 96.4 0.87 960 8.1 2.9 1■M1223-3BB71-2■■■ 1000 rpm, 6-pole 180 241 315 Δ 50.4 1720 94.8 95.7 95.6 0.79 360 8.5 2.8 1■M1223-3AC11-3■■■ 240 322 315 Δ 50.4 2293 95.0 95.9 95.9 0.81 470 8.4 2.7 1■M1223-3AC31-3■■■ 275 369 315 Δ 50.4 2627 95.1 96.0 96.0 0.82 530 8.5 2.7 1■M1223-3AC51-3■■■ 310 416 315 Δ 50.4 2961 95.2 96.1 96.2 0.83 590 8.1 2.5 1■M1223-3AC71-3■■■ 375 503 355 Δ 50.3 3582 95.4 96.2 96.0 0.83 710 9.9 2.8 1■M1223-3BC51-3■■■ 415 557 355 Δ 50.3 3964 95.5 96.3 96.1 0.84 780 9.8 2.5 1■M1223-3BC71-3■■■ For versions, see Article No. supplements and special versions 4/4 Siemens D 81.8 · 04/2014 1■M1223-3AC71-3■■■ © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 400 V, 50 Hz Premium Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.M1213-3AB11-2... 1260 1310 3.5 79 94 3000 1XB7 730 6SL3710-7LE33-1AA3 302 1.M1213-3AB31-2... 1440 1490 4.4 79 94 3000 1XB7 731 6SL3710-7LE35-0AA3 477 1.M1213-3AB51-2... 1620 1670 5.1 79 94 2500 1XB7 731 6SL3710-7LE36-1AA3 590 1.M1213-3AB71-2... 1780 1830 5.9 79 94 2500 1XB7 740 6SL3710-7LE37-5AA3 725 1.M1213-3BB51-2... 2220 2280 8.4 79 95 2200 1XB7 740 6SL3710-7LE38-4AA3 820 1.M1213-3BB71-2... 2350 2410 9 79 95 2200 1XB7 740 6SL3710-7LE38-4AA3 820 1.M1213-3AC11-3... 1290 1340 5.9 79 94 2500 1XB7 730 6SL3710-7LE33-8AA3 370 1.M1213-3AC31-3... 1460 1510 7.3 79 94 2500 1XB7 731 6SL3710-7LE35-0AA3 477 1.M1213-3AC51-3... 1650 1700 8.3 79 94 2500 1XB7 731 6SL3710-7LE35-0AA3 477 1.M1213-3AC71-3... 1750 1800 9.1 79 94 2500 1XB7 731 6SL3710-7LE36-1AA3 590 1.M1213-3BC51-3... 2220 2270 14.6 79 95 2200 1XB7 740 6SL3710-7LE37-5AA3 725 1.M1213-3BC71-3... 2370 2420 16.1 79 95 2200 1XB7 740 6SL3710-7LE37-5AA3 725 1.M1223-3AB11-2... 1260 1310 3.5 79 94 3000 1XB7 731 6SL3710-1PE33-7AA0 360 1.M1223-3AB31-2... 1440 1490 4.4 79 94 3000 1XB7 731 6SL3710-1PE35-8AA0 570 1.M1223-3AB51-2... 1620 1670 5.1 79 94 2500 1XB7 740 6SL3370-1PE36-6AA0 640 1.M1223-3AB71-2... 1780 1830 5.9 79 94 2500 1XB7 740 6SL3710-1GE37-5AA3 725 1.M1223-3BB51-2... 2220 2280 8.4 79 95 2200 1XB7 740 6SL3710-1GE41-0AA3 960 1.M1223-3BB71-2... 2350 2410 9 79 95 2200 1XB7 740 6SL3710-1GE41-0AA3 960 1.M1223-3AC11-3... 1290 1340 5.9 79 94 2500 1XB7 731 6SL3710-1PE33-7AA0 360 1.M1223-3AC31-3... 1460 1510 7.3 79 94 2500 1XB7 731 6SL3710-1PE35-8AA0 570 1.M1223-3AC51-3... 1650 1700 8.3 79 94 2500 1XB7 731 6SL3710-1PE35-8AA0 570 1.M1223-3AC71-3... 1750 1800 9.1 79 94 2500 1XB7 731 6SL3370-1PE36-6AA0 640 1.M1223-3BC51-3... 2220 2270 14.6 79 95 2200 1XB7 740 6SL3710-1PE37-4AA0 710 1.M1223-3BC71-3... 2370 2420 16.1 79 95 2200 1XB7 740 6SL3710-1GE38-4AA3 820 Siemens D 81.8 · 04/2014 4 4/5 © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency ■ Selection and ordering data 4 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LM1/1MM1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V 3000 rpm, 4-pole 225 302 315 Δ 100.6 716 95.4 95.9 95.6 0.88 295 7.2 2.4 1■M1212-3AB12-1■■■ 1■M1212-3AB32-1■■■ 285 382 315 Δ 100.5 907 95.8 96.3 95.9 0.89 370 8.8 3.0 305 409 315 Δ 100.4 971 95.8 96.1 95.7 0.89 395 9.5 3.2 1■M1212-3AB52-1■■■ 335 449 315 Δ 100.5 1067 95.7 96.3 95.9 0.91 425 7.8 2.6 1■M1212-3AB72-1■■■ 1■M1212-3BB52-1■■■ 410 550 355 Δ 100.4 1305 95.7 96.2 95.7 0.89 530 8.0 2.8 435 583 355 Δ 100.5 1385 95.7 96.3 95.9 0.89 560 7.1 2.5 1■M1212-3BB72-1■■■ 1500 rpm, 4-pole 225 302 315 Δ 50.5 1433 94.3 95.2 95.1 0.87 300 7.6 2.8 1■M1212-3AB12-2■■■ 285 382 315 Δ 50.5 1815 94.7 95.5 95.6 0.89 370 8.1 2.9 1■M1212-3AB32-2■■■ 320 429 315 Δ 50.4 2037 95.0 95.8 95.7 0.88 420 9.1 3.3 1■M1212-3AB52-2■■■ 380 510 315 Δ 50.4 2421 95.3 96.0 95.9 0.87 510 10.0 3.1 1■M1212-3AB72-2■■■ 435 583 355 Δ 50.4 2770 95.2 95.9 95.7 0.87 580 8.6 3.3 1■M1212-3BB52-2■■■ 480 644 355 Δ 50.4 3058 95.4 96.0 95.8 0.86 650 9.2 3.2 1■M1212-3BB72-2■■■ 1000 rpm, 6-pole 180 241 315 Δ 50.4 1719 94.7 95.4 95.3 0.79 265 8.8 2.9 1■M1212-3AC12-3■■■ 210 282 315 Δ 50.4 2006 94.9 95.6 95.5 0.80 305 9.3 3.0 1■M1212-3AC32-3■■■ 245 329 315 Δ 50.4 2340 94.9 95.7 95.7 0.83 340 8.8 2.8 1■M1212-3AC52-3■■■ 1■M1212-3AC72-3■■■ 270 362 315 Δ 50.4 2579 95.0 95.7 95.7 0.83 375 9.0 2.8 325 436 355 Δ 50.3 3104 94.9 95.6 95.3 0.84 450 10.6 3.2 1■M1212-3BC52-3■■■ 360 483 355 Δ 50.3 3438 95.1 95.7 95.3 0.83 500 11.3 2.9 1■M1212-3BC72-3■■■ 750 rpm, 6-pole 130 174 315 Δ 37.9 1656 93.9 94.7 94.5 0.75 205 9.0 3.3 1■M1212-3AC12-4■■■ 165 221 315 Δ 37.9 2102 94.1 95.0 94.9 0.78 245 9.1 3.1 1■M1212-3AC32-4■■■ 190 255 315 Δ 37.9 2420 94.1 95.1 95.2 0.83 265 8.4 2.8 1■M1212-3AC52-4■■■ 210 282 315 Δ 37.9 2674 94.3 95.2 95.3 0.82 300 8.7 2.8 1■M1212-3AC72-4■■■ 250 335 355 Δ 37.8 3184 94.4 95.2 95.0 0.83 350 10.4 3.1 1■M1212-3BC52-4■■■ 270 362 355 Δ 37.8 3438 94.4 95.3 95.2 0.85 370 9.7 2.9 1■M1212-3BC72-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V 3000 rpm, 4-pole 250 335 315 Δ 100.6 796 95.5 96.1 95.8 0.88 355 6.6 2.2 1■M1222-3AB12-1■■■ 1■M1222-3AB32-1■■■ 305 409 315 Δ 100.6 971 95.8 96.3 96.1 0.90 425 7.0 2.3 330 443 315 Δ 100.6 1051 95.8 96.3 95.9 0.90 460 7.5 2.5 1■M1222-3AB52-1■■■ 375 503 315 Δ 100.5 1194 95.9 96.4 96.1 0.91 510 7.9 2.6 1■M1222-3AB72-1■■■ 420 563 355 Δ 100.5 1337 95.7 96.3 95.9 0.89 590 6.6 2.4 1■M1222-3BB52-1■■■ 460 617 355 Δ 100.4 1464 95.9 96.4 95.9 0.89 640 7.8 2.8 1■M1222-3BB72-1■■■ 1500 rpm, 4-pole 240 322 315 Δ 50.6 1528 94.4 95.3 95.3 0.87 350 6.9 2.6 1■M1222-3AB12-2■■■ 320 429 315 Δ 50.5 2037 95.0 95.8 95.7 0.87 460 8.4 3.1 1■M1222-3AB32-2■■■ 350 469 315 Δ 50.5 2228 95.1 95.9 95.8 0.88 500 8.5 3.1 1■M1222-3AB52-2■■■ 395 530 315 Δ 50.5 2515 95.2 96.0 96.0 0.90 550 8.5 2.9 1■M1222-3AB72-2■■■ 480 644 355 Δ 50.4 3056 95.3 96.1 95.9 0.87 690 8.5 3.2 1■M1222-3BB52-2■■■ 505 677 355 Δ 50.4 3215 95.3 96.1 96.0 0.89 710 7.7 2.9 1■M1222-3BB72-2■■■ 1000 rpm, 6-pole 185 248 315 Δ 50.5 1768 94.6 95.5 95.4 0.81 290 7.9 2.5 1■M1222-3AC12-3■■■ 230 308 315 Δ 50.4 2197 95.0 95.7 95.6 0.80 360 8.9 2.9 1■M1222-3AC32-3■■■ 270 362 315 Δ 50.4 2579 95.0 95.7 95.8 0.83 410 8.4 2.7 1■M1222-3AC52-3■■■ 1■M1222-3AC72-3■■■ 300 402 315 Δ 50.4 2865 95.2 95.7 95.9 0.82 460 8.7 2.6 360 483 355 Δ 50.3 3439 95.0 95.7 95.5 0.85 530 9.3 2.9 1■M1222-3BC52-3■■■ 400 536 355 Δ 50.3 3821 95.2 95.9 95.6 0.85 590 10.2 2.6 1■M1222-3BC72-3■■■ 750 rpm, 6-pole 145 194 315 Δ 37.9 1847 93.9 94.9 94.9 0.78 235 8.2 2.8 1■M1222-3AC12-4■■■ 185 248 315 Δ 37.9 2356 94.2 95.1 95.2 0.80 290 8.2 2.8 1■M1222-3AC32-4■■■ 210 282 315 Δ 37.9 2675 94.2 95.2 95.4 0.83 320 7.6 2.5 1■M1222-3AC52-4■■■ 230 308 315 Δ 37.9 2930 94.2 95.3 95.5 0.84 345 7.6 2.5 1■M1222-3AC72-4■■■ 270 362 355 Δ 37.8 3439 94.4 95.3 95.3 0.85 400 9.2 2.9 1■M1222-3BC52-4■■■ 300 402 355 Δ 37.8 3821 94.5 95.4 95.4 0.86 440 9.3 2.6 1■M1222-3BC72-4■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC72-4■■■ Prated 4/6 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.M1212-3AB12-1... 1.M1212-3AB32-1... 1.M1212-3AB52-1... 1.M1212-3AB72-1... 1.M1212-3BB52-1... 1.M1212-3BB72-1... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 320 400 400 452 560 560 1.M1212-3AB12-2... 1.M1212-3AB32-2... 1.M1212-3AB52-2... 1.M1212-3AB72-2... 1.M1212-3BB52-2... 1.M1212-3BB72-2... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 320 400 452 560 710 710 1.M1212-3AC12-3... 1.M1212-3AC32-3... 1.M1212-3AC52-3... 1.M1212-3AC72-3... 1.M1212-3BC52-3... 1.M1212-3BC72-3... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 320 320 400 400 452 560 1.M1212-3AC12-4... 1.M1212-3AC32-4... 1.M1212-3AC52-4... 1.M1212-3AC72-4... 1.M1212-3BC52-4... 1.M1212-3BC72-4... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 6SL3710-7LG32-2AA3 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 208 250 320 320 400 400 1.M1222-3AB12-1... 1.M1222-3AB32-1... 1.M1222-3AB52-1... 1.M1222-3AB72-1... 1.M1222-3BB52-1... 1.M1222-3BB72-1... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 370 477 477 590 590 725 1.M1222-3AB12-2... 1.M1222-3AB32-2... 1.M1222-3AB52-2... 1.M1222-3AB72-2... 1.M1222-3BB52-2... 1.M1222-3BB72-2... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 370 477 590 590 725 725 1.M1222-3AC12-3... 1.M1222-3AC32-3... 1.M1222-3AC52-3... 1.M1222-3AC72-3... 1.M1222-3BC52-3... 1.M1222-3BC72-3... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GE33-1AA3 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 302 370 477 477 590 590 1.M1222-3AC12-4... 1.M1222-3AC32-4... 1.M1222-3AC52-4... 1.M1222-3AC72-4... 1.M1222-3BC52-4... 1.M1222-3BC72-4... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-1GE32-6AA3 6SL3710-1GE33-1AA3 6SL3710-1GE33-8AA3 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 250 302 370 370 477 477 Siemens D 81.8 · 04/2014 4 4/7 © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 500 V, 50 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LM1/1MM1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V 1500 rpm, 4-pole 4 160 215 315 Δ 50.3 1020 95.2 95.8 95.6 0.82 225 10.2 4.0 1■M1213-3AB12-2■■■ 230 308 315 Δ 50.4 1464 95.2 96.0 96.0 0.86 310 9.6 3.5 1■M1213-3AB32-2■■■ 295 396 315 Δ 50.4 1878 95.1 96.0 95.8 0.87 390 9.7 3.5 1■M1213-3AB52-2■■■ 390 523 315 Δ 50.4 2483 95.3 96.1 96.0 0.87 520 9.8 3.0 1■M1213-3AB72-2■■■ 460 617 355 Δ 50.4 2928 95.3 96.2 96.1 0.87 610 8.1 3.2 1■M1213-3BB52-2■■■ 505 677 355 Δ 50.4 3218 95.5 96.3 96.2 0.86 680 8.8 3.1 1■M1213-3BB72-2■■■ 1000 rpm, 6-pole 165 221 315 Δ 50.4 1576 94.8 95.6 95.4 0.78 245 9.4 3.1 1■M1213-3AC12-3■■■ 215 288 315 Δ 50.4 2054 95.0 95.8 95.7 0.80 310 9.1 3.0 1■M1213-3AC32-3■■■ 250 335 315 Δ 50.4 2388 94.9 95.8 95.9 0.83 350 8.5 2.7 1■M1213-3AC52-3■■■ 275 369 315 Δ 50.4 2627 95.1 95.9 96.0 0.83 385 8.7 2.8 1■M1213-3AC72-3■■■ 345 463 355 Δ 50.3 3295 95.2 96.0 95.9 0.84 475 10.0 3.0 1■M1213-3BC52-3■■■ 380 510 355 Δ 50.3 3629 95.4 96.1 96.0 0.82 540 10.4 2.7 1■M1213-3BC72-3■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V 1500 rpm, 4-pole 180 241 315 Δ 50.4 1146 95.1 95.9 95.8 0.85 265 9.1 3.4 1■M1223-3AB12-2■■■ 260 349 315 Δ 50.4 1657 95.5 96.2 96.1 0.84 385 10.1 3.8 1■M1223-3AB32-2■■■ 345 463 315 Δ 50.5 2197 95.2 96.0 96.0 0.88 490 8.7 3.1 1■M1223-3AB52-2■■■ 405 543 315 Δ 50.5 2579 95.1 96.0 96.1 0.90 560 8.3 2.9 1■M1223-3AB72-2■■■ 495 664 355 Δ 50.4 3152 95.5 96.3 96.3 0.86 720 8.1 3.1 1■M1223-3BB52-2■■■ 520 697 355 Δ 50.4 3311 95.4 96.3 96.3 0.88 740 7.4 2.8 1■M1223-3BB72-2■■■ 1000 rpm, 6-pole 170 228 315 Δ 50.4 1624 94.8 95.7 95.6 0.80 265 8.6 2.8 1■M1223-3AC12-3■■■ 240 322 315 Δ 50.4 2292 95.0 95.9 95.9 0.80 375 8.5 2.8 1■M1223-3AC32-3■■■ 275 369 315 Δ 50.4 2627 95.1 96.0 96.0 0.83 415 8.2 2.6 1■M1223-3AC52-3■■■ 310 416 315 Δ 50.4 2961 95.2 96.1 96.1 0.82 475 8.4 2.5 1■M1223-3AC72-3■■■ 375 503 355 Δ 50.4 3582 95.2 96.1 96.1 0.85 550 9.0 2.8 1■M1223-3BC52-3■■■ 425 570 355 Δ 50.3 4059 95.4 96.2 96.2 0.84 630 9.5 2.4 1■M1223-3BC72-3■■■ For versions, see Article No. supplements and special versions 4/8 Siemens D 81.8 · 04/2014 1■M1223-3AC72-3■■■ © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 500 V, 50 Hz Premium Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.M1213-3AB12-2... 1260 1310 3.5 79 94 3000 1XB7 730 6SL3710-7LG32-6AA3 250 1.M1213-3AB32-2... 1440 1490 4.4 79 94 3000 1XB7 730 6SL3710-7LG33-3AA3 320 1.M1213-3AB52-2... 1620 1670 5.1 79 94 2500 1XB7 731 6SL3710-7LG34-1AA3 400 1.M1213-3AB72-2... 1780 1830 5.9 79 94 2500 1XB7 731 6SL3710-7LG35-8AA3 560 1.M1213-3BB52-2... 2220 2280 8.4 79 95 2200 1XB7 740 6SL3710-7LG37-4AA3 710 1.M1213-3BB72-2... 2350 2410 9 79 95 2200 1XB7 740 6SL3710-7LG37-4AA3 710 1.M1213-3AC12-3... 1290 1340 5.9 79 94 2500 1XB7 730 6SL3710-7LG32-6AA3 250 1.M1213-3AC32-3... 1460 1510 7.3 79 94 2500 1XB7 730 6SL3710-7LG33-3AA3 320 1.M1213-3AC52-3... 1650 1700 8.3 79 94 2500 1XB7 730 6SL3710-7LG34-1AA3 400 1.M1213-3AC72-3... 1750 1800 9.1 79 94 2500 1XB7 731 6SL3710-7LG34-1AA3 400 1.M1213-3BC52-3... 2220 2270 14.6 79 95 2200 1XB7 731 6SL3710-7LG35-8AA3 560 1.M1213-3BC72-3... 2370 2420 16.1 79 95 2200 1XB7 731 6SL3710-7LG35-8AA3 560 1.M1223-3AB12-2... 1260 1310 3.5 79 94 3000 1XB7 730 6SL3710-1GE33-1AA3 302 1.M1223-3AB32-2... 1440 1490 4.4 79 94 3000 1XB7 731 6SL3710-1GE35-0AA3 477 1.M1223-3AB52-2... 1620 1670 5.1 79 94 2500 1XB7 731 6SL3710-1GE36-1AA3 590 1.M1223-3AB72-2... 1780 1830 5.9 79 94 2500 1XB7 731 6SL3710-1GE36-1AA3 590 1.M1223-3BB52-2... 2220 2280 8.4 79 95 2200 1XB7 740 6SL3710-1GE37-5AA3 725 1.M1223-3BB72-2... 2350 2410 9 79 95 2200 1XB7 740 6SL3710-1GE38-4AA3 820 1.M1223-3AC12-3... 1290 1340 5.9 79 94 2500 1XB7 730 6SL3710-1GE33-1AA3 302 1.M1223-3AC32-3... 1460 1510 7.3 79 94 2500 1XB7 731 6SL3710-1GE35-0AA3 477 1.M1223-3AC52-3... 1650 1700 8.3 79 94 2500 1XB7 731 6SL3710-1GE35-0AA3 477 1.M1223-3AC72-3... 1750 1800 9.1 79 94 2500 1XB7 731 6SL3710-1GE35-0AA3 477 1.M1223-3BC52-3... 2220 2270 14.6 79 95 2200 1XB7 731 6SL3710-1GE36-1AA3 590 1.M1223-3BC72-3... 2370 2420 16.1 79 95 2200 1XB7 740 6SL3710-1GE37-5AA3 725 Siemens D 81.8 · 04/2014 4 4/9 © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency ■ Selection and ordering data 4 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LM1/1MM1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V 3000 rpm, 4-pole 220 295 315 Δ 100.5 701 95.4 95.9 95.5 0.88 205 7.3 2.5 1■M1212-3AB13-1■■■ 1■M1212-3AB33-1■■■ 290 389 315 Δ 100.5 923 95.8 96.2 95.9 0.89 270 8.1 2.7 315 422 315 Δ 100.4 1003 95.8 96.2 95.7 0.89 290 9.6 3.2 1■M1212-3AB53-1■■■ 360 483 315 Δ 100.5 1146 95.9 96.3 95.9 0.90 330 9.1 3.0 1■M1212-3AB73-1■■■ 1■M1212-3BB53-1■■■ 425 570 355 Δ 100.5 1353 95.7 96.2 95.8 0.89 395 7.3 2.6 450 603 355 Δ 100.5 1433 95.7 96.3 96.0 0.89 415 6.5 2.3 1■M1212-3BB73-1■■■ 1500 rpm, 4-pole 210 282 315 Δ 50.4 1337 94.5 95.2 95.1 0.85 205 8.3 3.1 1■M1212-3AB13-2■■■ 290 389 315 Δ 50.4 1846 94.9 95.6 95.5 0.86 280 8.8 3.2 1■M1212-3AB33-2■■■ 325 436 315 Δ 50.4 2069 95.1 95.8 95.7 0.87 310 9.4 3.4 1■M1212-3AB53-2■■■ 370 496 315 Δ 50.4 2356 95.2 95.9 95.8 0.88 345 9.9 3.1 1■M1212-3AB73-2■■■ 420 563 355 Δ 50.4 2674 95.2 95.9 95.7 0.87 400 8.3 3.3 1■M1212-3BB53-2■■■ 470 630 355 Δ 50.4 2992 95.2 96.0 95.9 0.88 440 8.4 3.2 1■M1212-3BB73-2■■■ 1000 rpm, 6-pole 160 215 315 Y 50.4 1528 94.7 95.4 95.1 0.78 170 9.5 3.1 1■M1212-3AC13-3■■■ 200 268 315 Y 50.4 1910 94.9 95.6 95.4 0.80 205 9.7 3.1 1■M1212-3AC33-3■■■ 245 329 315 Y 50.4 2340 95.0 95.7 95.7 0.82 245 8.9 2.8 1■M1212-3AC53-3■■■ 1■M1212-3AC73-3■■■ 275 369 315 Δ 50.4 2626 95.1 95.7 95.8 0.83 275 9.0 2.8 325 436 355 Δ 50.3 3104 94.9 95.6 95.3 0.84 320 10.4 3.2 1■M1212-3BC53-3■■■ 360 483 355 Δ 50.3 3438 95.1 95.7 95.3 0.83 360 11.2 2.9 1■M1212-3BC73-3■■■ 750 rpm, 6-pole 130 174 315 Y 37.9 1656 93.8 94.7 94.5 0.76 142 8.9 3.2 1■M1212-3AC13-4■■■ 170 228 315 Y 37.9 2165 94.2 95.0 95.0 0.79 180 8.6 3.0 1■M1212-3AC33-4■■■ 190 255 315 Δ 37.9 2420 94.2 95.1 95.2 0.82 192 8.5 2.8 1■M1212-3AC53-4■■■ 205 275 315 Δ 37.9 2610 94.4 95.3 95.4 0.82 205 8.7 2.8 1■M1212-3AC73-4■■■ 250 335 355 Y 37.8 3184 94.3 95.2 95.0 0.84 245 10.3 3.1 1■M1212-3BC53-4■■■ 280 375 355 Δ 37.8 3565 94.5 95.3 95.2 0.84 275 10.5 2.8 1■M1212-3BC73-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V 3000 rpm, 4-pole 225 302 315 Δ 100.5 716 95.4 95.9 95.5 0.88 235 7.4 2.5 1■M1222-3AB13-1■■■ 1■M1222-3AB33-1■■■ 280 375 315 Δ 100.5 891 95.7 96.2 95.9 0.89 285 8.1 2.7 300 402 315 Δ 100.4 956 95.8 96.1 95.6 0.89 305 10.0 3.3 1■M1222-3AB53-1■■■ 345 463 315 Δ 100.4 1098 95.9 96.3 95.9 0.90 350 9.6 3.2 1■M1222-3AB73-1■■■ 385 516 355 Δ 100.4 1226 95.7 96.1 95.6 0.88 400 8.1 3.0 1■M1222-3BB53-1■■■ 425 570 355 Δ 100.5 1353 95.7 96.3 95.9 0.89 435 7.0 2.5 1■M1222-3BB73-1■■■ 1500 rpm, 4-pole 230 308 315 Δ 50.5 1465 94.4 95.2 95.2 0.86 245 7.7 2.9 1■M1222-3AB13-2■■■ 290 389 315 Δ 50.5 1846 94.8 95.6 95.6 0.88 300 8.3 3.0 1■M1222-3AB33-2■■■ 310 416 315 Δ 50.4 1974 95.0 95.7 95.6 0.88 320 9.3 3.3 1■M1222-3AB53-2■■■ 375 503 315 Δ 50.4 2388 95.2 95.9 95.9 0.89 385 9.5 3.1 1■M1222-3AB73-2■■■ 420 563 355 Δ 50.3 2676 95.3 95.9 95.7 0.85 450 9.4 3.7 1■M1222-3BB53-2■■■ 460 617 355 Δ 50.4 2929 95.2 96.0 95.9 0.88 475 8.3 3.2 1■M1222-3BB73-2■■■ 1000 rpm, 6-pole 170 228 315 Y 50.4 1624 94.6 95.3 95.2 0.79 198 8.9 2.9 1■M1222-3AC13-3■■■ 210 282 315 Δ 50.4 2006 94.9 95.6 95.5 0.80 240 9.3 3.0 1■M1222-3AC33-3■■■ 250 335 315 Δ 50.4 2388 95.0 95.7 95.7 0.83 275 8.9 2.8 1■M1222-3AC53-3■■■ 1■M1222-3AC73-3■■■ 270 362 315 Δ 50.4 2579 95.1 95.7 95.7 0.81 305 9.5 2.9 325 436 355 Δ 50.3 3104 94.9 95.6 95.3 0.85 350 10.3 3.2 1■M1222-3BC53-3■■■ 350 469 355 Δ 50.3 3343 95.1 95.7 95.3 0.83 385 11.6 3.0 1■M1222-3BC73-3■■■ 750 rpm, 6-pole 130 174 315 Y 37.9 1656 93.8 94.7 94.6 0.78 154 8.5 3.0 1■M1222-3AC13-4■■■ 170 228 315 Δ 37.9 2165 94.3 95.1 94.9 0.77 205 8.9 3.2 1■M1222-3AC33-4■■■ 195 261 315 Δ 37.9 2483 94.2 95.1 95.2 0.81 220 8.5 2.9 1■M1222-3AC53-4■■■ 210 282 315 Δ 37.9 2675 94.2 95.2 95.3 0.83 230 8.4 2.8 1■M1222-3AC73-4■■■ 250 335 355 Δ 37.8 3184 94.4 95.2 95.0 0.83 275 10.3 3.1 1■M1222-3BC53-4■■■ 270 362 355 Δ 37.8 3439 94.4 95.3 95.1 0.85 290 10.3 2.9 1■M1222-3BC73-4■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC73-4■■■ Prated 4/10 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.M1212-3AB13-1... 1.M1212-3AB33-1... 1.M1212-3AB53-1... 1.M1212-3AB73-1... 1.M1212-3BB53-1... 1.M1212-3BB73-1... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-7LG32-2AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 208 320 320 400 400 452 1.M1212-3AB13-2... 1.M1212-3AB33-2... 1.M1212-3AB53-2... 1.M1212-3AB73-2... 1.M1212-3BB53-2... 1.M1212-3BB73-2... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-7LG32-2AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG34-7AA3 208 320 320 400 452 452 1.M1212-3AC13-3... 1.M1212-3AC33-3... 1.M1212-3AC53-3... 1.M1212-3AC73-3... 1.M1212-3BC53-3... 1.M1212-3BC73-3... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 6SL3710-7LG31-8AA3 6SL3710-7LG32-2AA3 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 170 208 250 320 320 400 1.M1212-3AC13-4... 1.M1212-3AC33-4... 1.M1212-3AC53-4... 1.M1212-3AC73-4... 1.M1212-3BC53-4... 1.M1212-3BC73-4... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 6SL3710-7LG31-5AA3 6SL3710-7LG32-2AA3 6SL3710-7LG32-2AA3 6SL3710-7LG32-2AA3 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 142 208 208 208 250 320 1.M1222-3AB13-1... 1.M1222-3AB33-1... 1.M1222-3AB53-1... 1.M1222-3AB73-1... 1.M1222-3BB53-1... 1.M1222-3BB73-1... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-1GH32-6AA3 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 250 320 320 400 400 452 1.M1222-3AB13-2... 1.M1222-3AB33-2... 1.M1222-3AB53-2... 1.M1222-3AB73-2... 1.M1222-3BB53-2... 1.M1222-3BB73-2... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GH32-6AA3 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 250 320 320 400 452 560 1.M1222-3AC13-3... 1.M1222-3AC33-3... 1.M1222-3AC53-3... 1.M1222-3AC73-3... 1.M1222-3BC53-3... 1.M1222-3BC73-3... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 6SL3710-1GH32-2AA3 6SL3710-1GH32-6AA3 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 208 250 320 320 400 400 1.M1222-3AC13-4... 1.M1222-3AC33-4... 1.M1222-3AC53-4... 1.M1222-3AC73-4... 1.M1222-3BC53-4... 1.M1222-3BC73-4... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 6SL3710-1GH31-8AA3 6SL3710-1GH32-2AA3 6SL3710-1GH32-6AA3 6SL3710-1GH32-6AA3 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 171 208 250 250 320 320 Siemens D 81.8 · 04/2014 4 4/11 © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 690 V, 50 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LM1/1MM1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V 1500 rpm, 4-pole 4 155 208 315 Δ 50.3 987 95.2 95.8 95.5 0.80 160 10.7 4.3 1■M1213-3AB13-2■■■ 230 308 315 Δ 50.3 1465 95.4 96.1 95.9 0.83 230 10.7 4.1 1■M1213-3AB33-2■■■ 325 436 315 Δ 50.4 2069 95.1 96.0 95.8 0.87 310 9.2 3.4 1■M1213-3AB53-2■■■ 380 510 315 Δ 50.4 2419 95.3 96.0 96.0 0.88 355 9.6 3.1 1■M1213-3AB73-2■■■ 455 610 355 Δ 50.4 2897 95.3 96.1 96.1 0.87 430 7.7 3.0 1■M1213-3BB53-2■■■ 480 644 355 Δ 50.4 3056 95.4 96.2 96.2 0.88 450 8.2 3.2 1■M1213-3BB73-2■■■ 1000 rpm, 6-pole 155 208 315 Y 50.3 1481 94.8 95.5 95.3 0.77 166 9.7 3.2 1■M1213-3AC13-3■■■ 200 268 315 Y 50.4 1910 95.0 95.8 95.7 0.80 205 9.6 3.1 1■M1213-3AC33-3■■■ 250 335 315 Y 50.4 2388 95.0 95.9 95.9 0.82 250 8.7 2.8 1■M1213-3AC53-3■■■ 285 382 315 Δ 50.4 2722 95.1 96.0 96.0 0.83 285 8.6 2.7 1■M1213-3AC73-3■■■ 345 463 355 Δ 50.3 3295 95.2 96.0 95.9 0.84 340 9.8 3.0 1■M1213-3BC53-3■■■ 385 516 355 Δ 50.3 3677 95.4 96.1 96.0 0.82 385 10.5 2.7 1■M1213-3BC73-3■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V 1500 rpm, 4-pole 145 194 315 Δ 50.3 924 95.3 95.8 95.5 0.79 168 11.1 4.5 1■M1223-3AB13-2■■■ 235 315 315 Δ 50.4 1496 95.3 96.1 96.0 0.85 250 10.0 3.7 1■M1223-3AB33-2■■■ 285 382 315 Δ 50.4 1815 95.2 96.0 95.8 0.87 300 9.9 3.6 1■M1223-3AB53-2■■■ 380 510 315 Δ 50.4 2419 95.2 96.0 96.0 0.89 390 9.3 3.1 1■M1223-3AB73-2■■■ 455 610 355 Δ 50.4 2900 95.5 96.2 96.1 0.85 485 8.7 3.4 1■M1223-3BB53-2■■■ 480 644 355 Δ 50.4 3056 95.4 96.2 96.2 0.88 495 8.0 3.1 1■M1223-3BB73-2■■■ 1000 rpm, 6-pole 155 208 315 Y 50.4 1480 94.8 95.5 95.4 0.77 184 9.5 3.2 1■M1223-3AC13-3■■■ 210 282 315 Δ 50.4 2006 95.0 95.8 95.7 0.80 240 9.2 3.0 1■M1223-3AC33-3■■■ 260 349 315 Δ 50.4 2484 95.0 95.9 95.9 0.83 285 8.5 2.7 1■M1223-3AC53-3■■■ 280 375 315 Δ 50.4 2674 95.2 96.0 95.9 0.81 315 9.1 2.8 1■M1223-3AC73-3■■■ 340 456 355 Δ 50.3 3248 95.2 96.0 95.9 0.84 370 9.7 3.0 1■M1223-3BC53-3■■■ 360 483 355 Δ 50.3 3438 95.4 96.1 95.9 0.82 400 11.1 2.9 1■M1223-3BC73-3■■■ For versions, see Article No. supplements and special versions 4/12 Siemens D 81.8 · 04/2014 1■M1223-3AC73-3■■■ © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 690 V, 50 Hz Premium Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.M1213-3AB13-2... 1260 1310 3.5 79 94 3000 1XB7 730 6SL3710-7LG31-8AA3 170 1.M1213-3AB33-2... 1440 1490 4.4 79 94 3000 1XB7 730 6SL3710-7LG32-6AA3 250 1.M1213-3AB53-2... 1620 1670 5.1 79 94 2500 1XB7 730 6SL3710-7LG33-3AA3 320 1.M1213-3AB73-2... 1780 1830 5.9 79 94 2500 1XB7 731 6SL3710-7LG34-1AA3 400 1.M1213-3BB53-2... 2220 2280 8.4 79 95 2200 1XB7 731 6SL3710-7LG34-7AA3 452 1.M1213-3BB73-2... 2350 2410 9 79 95 2200 1XB7 731 6SL3710-7LG34-7AA3 452 1.M1213-3AC13-3... 1290 1340 5.9 79 94 2500 1XB7 730 6SL3710-7LG31-8AA3 170 1.M1213-3AC33-3... 1460 1510 7.3 79 94 2500 1XB7 730 6SL3710-7LG32-2AA3 208 1.M1213-3AC53-3... 1650 1700 8.3 79 94 2500 1XB7 730 6SL3710-7LG32-6AA3 250 1.M1213-3AC73-3... 1750 1800 9.1 79 94 2500 1XB7 730 6SL3710-7LG33-3AA3 320 1.M1213-3BC53-3... 2220 2270 14.6 79 95 2200 1XB7 730 6SL3710-7LG34-1AA3 400 1.M1213-3BC73-3... 2370 2420 16.1 79 95 2200 1XB7 731 6SL3710-7LG34-1AA3 400 1.M1223-3AB13-2... 1260 1310 3.5 79 94 3000 1XB7 730 6SL3710-1GH31-8AA3 171 1.M1223-3AB33-2... 1440 1490 4.4 79 94 3000 1XB7 730 6SL3710-1GH32-6AA3 250 1.M1223-3AB53-2... 1620 1670 5.1 79 94 2500 1XB7 730 6SL3710-1GH33-3AA3 320 1.M1223-3AB73-2... 1780 1830 5.9 79 94 2500 1XB7 731 6SL3710-1GH34-1AA3 400 1.M1223-3BB53-2... 2220 2280 8.4 79 95 2200 1XB7 731 6SL3710-1GH35-8AA3 560 1.M1223-3BB73-2... 2350 2410 9 79 95 2200 1XB7 731 6SL3710-1GH35-8AA3 560 1.M1223-3AC13-3... 1290 1340 5.9 79 94 2500 1XB7 730 6SL3710-1GH32-2AA3 208 1.M1223-3AC33-3... 1460 1510 7.3 79 94 2500 1XB7 730 6SL3710-1GH32-6AA3 250 1.M1223-3AC53-3... 1650 1700 8.3 79 94 2500 1XB7 730 6SL3710-1GH33-3AA3 320 1.M1223-3AC73-3... 1750 1800 9.1 79 94 2500 1XB7 730 6SL3710-1GH33-3AA3 320 1.M1223-3BC53-3... 2220 2270 14.6 79 95 2200 1XB7 731 6SL3710-1GH34-1AA3 400 1.M1223-3BC73-3... 2370 2420 16.1 79 95 2200 1XB7 731 6SL3710-1GH34-1AA3 400 Siemens D 81.8 · 04/2014 4 4/13 © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency ■ Selection and ordering data 4 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LM1/1MM1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V 3600 rpm, 4-pole 235 315 315 Δ 120.4 623 95.6 95.9 95.2 0.87 340 8.7 3.0 1■M1212-3AB15-5■■■ 275 369 315 Δ 120.4 730 95.8 96.1 95.4 0.87 395 10.7 3.6 1■M1212-3AB35-5■■■ 320 429 315 Δ 120.5 849 95.7 96.1 95.5 0.90 445 8.5 2.8 1■M1212-3AB55-5■■■ 360 483 315 Δ 120.5 955 95.9 96.2 95.7 0.90 500 9.3 3.0 1■M1212-3AB75-5■■■ 3000 rpm, 4-pole 420 563 355 Δ 100.5 1337 95.7 96.3 95.9 0.89 590 6.6 2.4 1■M1212-3BB55-1■■■ 1■M1212-3BB75-1■■■ 465 624 355 Δ 100.4 1480 95.9 96.4 95.9 0.89 650 7.7 2.8 1800 rpm, 4-pole 260 349 315 Δ 60.5 1379 95.1 95.8 95.5 0.85 385 8.4 3.1 1■M1212-3AB15-6■■■ 1■M1212-3AB35-6■■■ 320 429 315 Δ 60.5 1698 95.4 96.0 95.9 0.88 455 8.7 3.1 1■M1212-3AB55-6■■■ 355 476 315 Δ 60.5 1883 95.5 96.1 96.0 0.89 500 8.9 3.1 430 577 315 Δ 60.4 2283 95.9 96.4 96.2 0.86 620 10.9 3.2 1■M1212-3AB75-6■■■ 520 697 355 Δ 60.4 2759 95.6 96.3 96.0 0.87 750 8.6 3.3 1■M1212-3BB55-6■■■ 1■M1212-3BB75-6■■■ 545 731 355 Δ 60.4 2892 95.6 96.3 96.2 0.89 760 7.9 3.0 1200 rpm, 6-pole 215 288 315 Δ 60.5 1712 95.0 95.7 95.6 0.81 335 8.1 2.5 1■M1212-3AC15-7■■■ 260 349 315 Δ 60.4 2070 95.3 95.7 95.9 0.83 390 8.6 2.6 1■M1212-3AC35-7■■■ 310 416 315 Δ 60.4 2468 95.5 95.7 96.0 0.83 475 9.0 2.8 1■M1212-3AC55-7■■■ 1■M1212-3AC75-7■■■ 335 449 315 Δ 60.4 2666 95.5 95.7 96.1 0.84 500 8.9 2.7 395 530 355 Δ 60.3 3144 95.4 95.9 95.5 0.84 590 11.0 3.1 1■M1212-3BC55-7■■■ 1■M1212-3BC75-7■■■ 445 597 355 Δ 60.3 3542 95.4 96.0 95.6 0.85 660 10.5 2.8 900 rpm, 6-pole 175 235 315 Δ 45.4 1858 94.6 95.4 95.3 0.79 280 8.4 2.8 1■M1212-3AC15-8■■■ 1■M1212-3AC35-8■■■ 210 282 315 Δ 45.4 2229 94.9 95.6 95.4 0.76 350 9.2 3.2 245 329 315 Δ 45.4 2601 94.8 95.7 95.7 0.83 370 8.2 2.6 1■M1212-3AC55-8■■■ 1■M1212-3AC75-8■■■ 270 362 315 Δ 45.4 2866 94.9 95.8 95.8 0.83 410 8.3 2.6 310 416 355 Δ 45.3 3291 94.8 95.6 95.5 0.86 455 9.4 3.0 1■M1212-3BC55-8■■■ 345 463 355 Δ 45.3 3661 95.0 95.7 95.5 0.85 510 9.7 2.7 1■M1212-3BC75-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G120P, SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V 3600 rpm, 4-pole 230 308 315 Δ 120.4 610 95.6 95.8 95.1 0.87 360 9.6 3.2 1■M1222-3AB15-5■■■ 285 382 315 Δ 120.5 756 95.9 96.2 95.7 0.89 435 8.8 2.9 1■M1222-3AB35-5■■■ 315 422 315 Δ 120.4 836 95.8 96.0 95.3 0.89 485 9.8 3.2 1■M1222-3AB55-5■■■ 1■M1222-3AB75-5■■■ 340 456 315 Δ 120.4 902 95.8 96.0 95.3 0.88 530 11.6 3.9 3000 rpm, 4-pole 420 563 355 Δ 100.4 1337 95.8 96.3 95.8 0.89 640 7.6 2.7 1■M1222-3BB55-1■■■ 450 603 355 Δ 100.5 1433 95.8 96.4 96.0 0.89 690 6.6 2.4 1■M1222-3BB75-1■■■ 1800 rpm, 4-pole 255 342 315 Δ 60.4 1353 95.1 95.7 95.5 0.85 410 8.6 3.2 1■M1222-3AB15-6■■■ 320 429 315 Δ 60.4 1698 95.4 96.1 95.9 0.87 500 9.0 3.2 1■M1222-3AB35-6■■■ 365 489 315 Δ 60.4 1937 95.5 96.1 96.0 0.88 570 9.1 3.2 1■M1222-3AB55-6■■■ 420 563 315 Δ 60.4 2228 95.7 96.3 96.2 0.89 640 9.5 3.3 1■M1222-3AB75-6■■■ 500 671 355 Δ 60.4 2653 95.5 96.2 96.0 0.88 770 7.6 2.9 1■M1222-3BB55-6■■■ 560 751 355 Δ 60.4 2971 95.7 96.4 96.2 0.88 870 8.7 3.3 1■M1222-3BB75-6■■■ 1200 rpm, 6-pole 220 295 315 Δ 60.4 1751 95.2 95.7 95.6 0.79 380 9.0 2.9 1■M1222-3AC15-7■■■ 265 355 315 Δ 60.4 2109 95.4 95.7 95.9 0.82 440 8.9 2.7 1■M1222-3AC35-7■■■ 305 409 315 Δ 60.4 2428 95.5 95.7 96.0 0.83 500 8.9 2.7 1■M1222-3AC55-7■■■ 340 456 315 Δ 60.4 2706 95.6 95.7 96.2 0.84 550 8.6 2.6 1■M1222-3AC75-7■■■ 395 530 355 Δ 60.3 3144 95.4 95.9 95.5 0.84 640 10.9 3.1 1■M1222-3BC55-7■■■ 1■M1222-3BC75-7■■■ 435 583 355 Δ 60.3 3462 95.5 96.0 95.6 0.85 700 10.8 2.9 900 rpm, 6-pole 170 228 315 Δ 45.4 1804 94.5 95.3 95.1 0.76 310 8.8 3.1 1■M1222-3AC15-8■■■ 215 288 315 Δ 45.4 2282 94.8 95.6 95.5 0.80 370 8.7 2.9 1■M1222-3AC35-8■■■ 245 329 315 Δ 45.4 2600 94.8 95.7 95.7 0.82 410 8.4 2.7 1■M1222-3AC55-8■■■ 270 362 315 Δ 45.4 2866 94.9 95.8 95.8 0.84 440 8.0 2.6 1■M1222-3AC75-8■■■ 310 416 355 Δ 45.3 3290 94.9 95.6 95.4 0.85 500 10.0 3.0 1■M1222-3BC55-8■■■ 345 463 355 Δ 45.3 3661 95.1 95.8 95.5 0.84 560 10.8 2.7 1■M1222-3BC75-8■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC75-8■■■ Prated 4/14 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.M1212-3AB15-5... 1.M1212-3AB35-5... 1.M1212-3AB55-5... 1.M1212-3AB75-5... 1260 1440 1620 1780 1310 1490 1670 1830 3.5 4.4 5.1 5.9 79 79 79 79 94 94 94 94 3600 3600 3600 3600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LE33-8AA3 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 370 477 477 590 1.M1212-3BB55-1... 1.M1212-3BB75-1... 2220 2350 2280 2410 8.4 9 79 79 95 95 3300 3300 1XB7 731 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 590 725 1.M1212-3AB15-6... 1.M1212-3AB35-6... 1.M1212-3AB55-6... 1.M1212-3AB75-6... 1.M1212-3BB55-6... 1.M1212-3BB75-6... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 2750 2750 2750 2750 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE38-4AA3 477 477 590 725 820 820 1.M1212-3AC15-7... 1.M1212-3AC35-7... 1.M1212-3AC55-7... 1.M1212-3AC75-7... 1.M1212-3BC55-7... 1.M1212-3BC75-7... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-7LE33-8AA3 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 370 477 477 590 590 725 1.M1212-3AC15-8... 1.M1212-3AC35-8... 1.M1212-3AC55-8... 1.M1212-3AC75-8... 1.M1212-3BC55-8... 1.M1212-3BC75-8... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LE33-1AA3 6SL3710-7LE33-8AA3 6SL3710-7LE33-8AA3 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 302 370 370 477 477 590 1.M1222-3AB15-5... 1.M1222-3AB35-5... 1.M1222-3AB55-5... 1.M1222-3AB75-5... 1260 1440 1620 1780 1310 1490 1670 1830 3.5 4.4 5.1 5.9 79 79 79 79 94 94 94 94 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1PE33-7AA0 6SL3710-1PE34-6AA0 6SL3710-1PE35-8AA0 6SL3710-1PE35-8AA0 360 450 570 570 1.M1222-3BB55-1... 1.M1222-3BB75-1... 2220 2350 2280 2410 8.4 9 79 79 95 95 3300 3300 1XB7 740 1XB7 740 6SL3370-1PE36-6AA0 6SL3710-1PE37-4AA0 640 710 1.M1222-3AB15-6... 1.M1222-3AB35-6... 1.M1222-3AB55-6... 1.M1222-3AB75-6... 1.M1222-3BB55-6... 1.M1222-3BB75-6... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 2750 2750 2750 2750 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1PE34-6AA0 6SL3710-1PE35-8AA0 6SL3710-1PE35-8AA0 6SL3370-1PE36-6AA0 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 450 570 570 640 820 960 1.M1222-3AC15-7... 1.M1222-3AC35-7... 1.M1222-3AC55-7... 1.M1222-3AC75-7... 1.M1222-3BC55-7... 1.M1222-3BC75-7... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1PE34-6AA0 6SL3710-1PE34-6AA0 6SL3710-1PE35-8AA0 6SL3710-1PE35-8AA0 6SL3370-1PE36-6AA0 6SL3710-1PE37-4AA0 450 450 570 570 640 710 1.M1222-3AC15-8... 1.M1222-3AC35-8... 1.M1222-3AC55-8... 1.M1222-3AC75-8... 1.M1222-3BC55-8... 1.M1222-3BC75-8... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1PE33-7AA0 6SL3710-1PE34-6AA0 6SL3710-1PE34-6AA0 6SL3710-1PE34-6AA0 6SL3710-1PE35-8AA0 6SL3710-1PE35-8AA0 360 450 450 450 570 570 Siemens D 81.8 · 04/2014 4 4/15 © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 460 V, 60 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LM1/1MM1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V 1800 rpm, 4-pole 4 235 315 315 Δ 60.4 1247 95.4 96.2 95.8 0.84 350 9.2 3.5 1■M1213-3AB15-6■■■ 290 389 315 Δ 60.4 1539 95.7 96.3 96.2 0.87 415 9.6 3.4 1■M1213-3AB35-6■■■ 365 489 315 Δ 60.5 1937 95.5 96.2 96.1 0.89 510 8.7 3.0 1■M1213-3AB55-6■■■ 445 597 315 Δ 60.4 2363 95.9 96.5 96.4 0.87 640 10.4 3.1 1■M1213-3AB75-6■■■ 550 738 355 Δ 60.4 2918 95.8 96.5 96.4 0.87 790 8.2 3.1 1■M1213-3BB55-6■■■ 570 764 355 Δ 60.4 3025 95.7 96.5 96.5 0.89 800 7.5 2.8 1■M1213-3BB75-6■■■ 1200 rpm, 6-pole 220 295 315 Δ 60.5 1752 95.0 95.9 95.8 0.81 340 8.0 2.5 1■M1213-3AC15-7■■■ 270 362 315 Δ 60.4 2150 95.3 96.1 96.1 0.83 405 8.2 2.5 1■M1213-3AC35-7■■■ 310 416 315 Δ 60.4 2468 95.6 96.3 96.2 0.82 470 9.1 2.8 1■M1213-3AC55-7■■■ 345 463 315 Δ 60.4 2746 95.6 96.3 96.3 0.83 520 8.5 2.6 1■M1213-3AC75-7■■■ 435 583 355 Δ 60.3 3462 95.7 96.4 96.2 0.84 650 9.9 2.9 1■M1213-3BC55-7■■■ 475 637 355 Δ 60.3 3781 95.7 96.4 96.3 0.85 700 9.9 2.6 1■M1213-3BC75-7■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G120P, SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V 1800 rpm, 4-pole 235 315 315 Δ 60.4 1247 95.4 96.2 95.8 0.84 380 9.3 3.5 1■M1223-3AB15-6■■■ 290 389 315 Δ 60.4 1540 95.7 96.3 96.2 0.86 460 9.8 3.6 1■M1223-3AB35-6■■■ 370 496 315 Δ 60.4 1963 95.6 96.3 96.2 0.88 570 9.1 3.2 1■M1223-3AB55-6■■■ 430 577 315 Δ 60.4 2281 95.7 96.4 96.4 0.89 660 9.2 3.2 1■M1223-3AB75-6■■■ 520 697 355 Δ 60.5 2759 95.6 96.4 96.4 0.88 800 7.3 2.8 1■M1223-3BB55-6■■■ 590 791 355 Δ 60.4 3130 95.9 96.6 96.5 0.88 910 8.4 3.2 1■M1223-3BB75-6■■■ 1200 rpm, 6-pole 225 302 315 Δ 60.4 1791 95.3 96.0 95.9 0.79 390 8.8 2.8 1■M1223-3AC15-7■■■ 270 362 315 Δ 60.4 2149 95.4 96.2 96.1 0.82 450 8.6 2.7 1■M1223-3AC35-7■■■ 315 422 315 Δ 60.4 2507 95.5 96.3 96.2 0.83 520 8.5 2.6 1■M1223-3AC55-7■■■ 350 469 315 Δ 60.4 2786 95.6 96.4 96.3 0.84 570 8.3 2.6 1■M1223-3AC75-7■■■ 430 577 355 Δ 60.3 3423 95.6 96.4 96.1 0.84 700 9.9 2.9 1■M1223-3BC55-7■■■ 470 630 355 Δ 60.3 3741 95.7 96.5 96.3 0.85 750 10.0 2.6 1■M1223-3BC75-7■■■ For versions, see Article No. supplements and special versions 4/16 Siemens D 81.8 · 04/2014 1■M1223-3AC75-7■■■ © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 460 V, 60 Hz Premium Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.M1213-3AB15-6... 1260 1310 3.5 79 94 3000 1XB7 730 6SL3710-7LE33-8AA3 370 1.M1213-3AB35-6... 1440 1490 4.4 79 94 3000 1XB7 731 6SL3710-7LE35-0AA3 477 1.M1213-3AB55-6... 1620 1670 5.1 79 94 2750 1XB7 731 6SL3710-7LE36-1AA3 590 1.M1213-3AB75-6... 1780 1830 5.9 79 94 2750 1XB7 740 6SL3710-7LE37-5AA3 725 1.M1213-3BB55-6... 2220 2280 8.4 79 95 2200 1XB7 740 6SL3710-7LE38-4AA3 820 1.M1213-3BB75-6... 2350 2410 9 79 95 2200 1XB7 740 6SL3710-7LE38-4AA3 820 1.M1213-3AC15-7... 1290 1340 5.9 79 94 2500 1XB7 730 6SL3710-7LE33-8AA3 370 1.M1213-3AC35-7... 1460 1510 7.3 79 94 2500 1XB7 731 6SL3710-7LE35-0AA3 477 1.M1213-3AC55-7... 1650 1700 8.3 79 94 2500 1XB7 731 6SL3710-7LE35-0AA3 477 1.M1213-3AC75-7... 1750 1800 9.1 79 94 2500 1XB7 731 6SL3710-7LE36-1AA3 590 1.M1213-3BC55-7... 2220 2270 14.6 79 95 2200 1XB7 740 6SL3710-7LE37-5AA3 725 1.M1213-3BC75-7... 2370 2420 16.1 79 95 2200 1XB7 740 6SL3710-7LE37-5AA3 725 1.M1223-3AB15-6... 1260 1310 3.5 79 94 3000 1XB7 731 6SL3710-1PE34-6AA0 450 1.M1223-3AB35-6... 1440 1490 4.4 79 94 3000 1XB7 731 6SL3710-1PE35-8AA0 570 1.M1223-3AB55-6... 1620 1670 5.1 79 94 2750 1XB7 731 6SL3710-1PE35-8AA0 570 1.M1223-3AB75-6... 1780 1830 5.9 79 94 2750 1XB7 740 6SL3710-1PE37-4AA0 710 1.M1223-3BB55-6... 2220 2280 8.4 79 95 2200 1XB7 740 6SL3710-1GE38-4AA3 820 1.M1223-3BB75-6... 2350 2410 9 79 95 2200 1XB7 740 6SL3710-1GE41-0AA3 960 1.M1223-3AC15-7... 1290 1340 5.9 79 94 2500 1XB7 731 6SL3710-1PE34-6AA0 450 1.M1223-3AC35-7... 1460 1510 7.3 79 94 2500 1XB7 731 6SL3710-1PE34-6AA0 450 1.M1223-3AC55-7... 1650 1700 8.3 79 94 2500 1XB7 731 6SL3710-1PE35-8AA0 570 1.M1223-3AC75-7... 1750 1800 9.1 79 94 2500 1XB7 731 6SL3710-1PE35-8AA0 570 1.M1223-3BC55-7... 2220 2270 14.6 79 95 2200 1XB7 740 6SL3710-1PE37-4AA0 710 1.M1223-3BC75-7... 2370 2420 16.1 79 95 2200 1XB7 740 6SL3710-1GE38-4AA3 820 Siemens D 81.8 · 04/2014 4 4/17 © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency ■ Selection and ordering data 4 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LM1/1MM1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V 3600 rpm, 4-pole 220 295 315 Δ 120.5 584 95.5 95.8 95.1 0.88 245 8.6 2.8 1■M1212-3AB16-5■■■ 270 362 315 Δ 120.4 717 95.8 96.0 95.3 0.87 305 10.6 3.6 1■M1212-3AB36-5■■■ 300 402 315 Δ 120.4 796 95.6 95.8 95.1 0.88 335 11.1 3.7 1■M1212-3AB56-5■■■ 340 456 315 Δ 120.4 902 95.8 96.0 95.3 0.88 380 11.5 3.8 1■M1212-3AB76-5■■■ 3000 rpm, 4-pole 405 543 355 Δ 100.5 1289 95.6 96.2 95.8 0.89 450 6.6 2.4 1■M1212-3BB56-1■■■ 1■M1212-3BB76-1■■■ 450 603 355 Δ 100.5 1433 95.7 96.3 95.9 0.89 495 7.2 2.6 1800 rpm, 4-pole 235 315 315 Δ 60.4 1247 94.9 95.6 95.3 0.86 270 8.5 3.1 1■M1212-3AB16-6■■■ 1■M1212-3AB36-6■■■ 300 402 315 Δ 60.4 1593 95.4 96.0 95.7 0.85 350 10.2 3.8 1■M1212-3AB56-6■■■ 335 449 315 Δ 60.4 1777 95.5 96.1 95.8 0.87 380 10.0 3.6 395 530 315 Δ 60.4 2097 95.8 96.3 96.0 0.86 450 11.5 3.5 1■M1212-3AB76-6■■■ 480 644 355 Δ 60.4 2547 95.5 96.2 95.9 0.87 540 9.2 3.5 1■M1212-3BB56-6■■■ 1■M1212-3BB76-6■■■ 520 697 355 Δ 60.3 2761 95.7 96.3 95.9 0.86 590 10.1 3.6 1200 rpm, 6-pole 200 268 315 Δ 60.4 1592 95.0 95.7 95.4 0.79 250 9.2 2.9 1■M1212-3AC16-7■■■ 240 322 315 Δ 60.4 1910 95.3 95.7 95.6 0.81 295 9.7 3.0 1■M1212-3AC36-7■■■ 280 375 315 Δ 60.4 2229 95.3 95.7 95.9 0.83 335 8.9 2.8 1■M1212-3AC56-7■■■ 1■M1212-3AC76-7■■■ 305 409 315 Δ 60.4 2428 95.4 95.7 95.9 0.83 360 9.4 2.9 360 483 355 Δ 60.3 2865 95.3 95.7 95.1 0.81 440 12.4 3.5 1■M1212-3BC56-7■■■ 1■M1212-3BC76-7■■■ 395 530 355 Δ 60.3 3144 95.3 95.8 95.3 0.83 470 12.0 3.1 900 rpm, 6-pole 155 208 315 Y 45.4 1645 94.4 95.1 95.0 0.78 198 9.0 3.0 1■M1212-3AC16-8■■■ 1■M1212-3AC36-8■■■ 190 255 315 Δ 45.3 2016 94.9 95.5 95.2 0.75 250 9.8 3.5 230 308 315 Δ 45.4 2441 94.8 95.6 95.5 0.82 280 8.8 2.9 1■M1212-3AC56-8■■■ 1■M1212-3AC76-8■■■ 245 329 315 Δ 45.3 2600 94.9 95.7 95.5 0.80 305 9.6 2.8 290 389 355 Δ 45.3 3077 94.8 95.5 95.2 0.84 340 10.7 3.2 1■M1212-3BC56-8■■■ 320 429 355 Δ 45.3 3395 94.9 95.6 95.3 0.84 375 10.8 2.9 1■M1212-3BC76-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V 3600 rpm, 4-pole 205 275 315 Δ 120.4 544 95.4 95.6 94.8 0.86 260 10.8 3.7 1■M1222-3AB16-5■■■ 235 315 315 Δ 120.3 624 95.6 95.7 94.9 0.86 300 12.3 4.2 1■M1222-3AB36-5■■■ 255 342 315 Δ 120.3 677 95.3 95.4 94.4 0.85 330 13.3 4.6 1■M1222-3AB56-5■■■ 1■M1222-3AB76-5■■■ 330 443 315 Δ 120.4 875 95.8 96.1 95.5 0.90 400 9.7 3.2 3000 rpm, 4-pole 395 530 355 Δ 100.5 1258 95.6 96.2 95.7 0.89 485 7.0 2.5 1■M1222-3BB56-1■■■ 425 570 355 Δ 100.4 1353 95.8 96.2 95.8 0.89 520 8.1 2.9 1■M1222-3BB76-1■■■ 1800 rpm, 4-pole 230 308 315 Δ 60.5 1220 94.9 95.5 95.3 0.87 290 8.2 3.0 1■M1222-3AB16-6■■■ 295 396 315 Δ 60.4 1567 95.4 95.9 95.7 0.86 375 10.1 3.6 1■M1222-3AB36-6■■■ 330 443 315 Δ 60.4 1751 95.5 96.1 95.8 0.87 415 10.0 3.6 1■M1222-3AB56-6■■■ 390 523 315 Δ 60.3 2070 95.8 96.3 96.0 0.85 500 11.8 3.6 1■M1222-3AB76-6■■■ 475 637 355 Δ 60.3 2522 95.6 96.2 95.8 0.86 600 9.5 3.6 1■M1222-3BB56-6■■■ 505 677 355 Δ 60.4 2679 95.5 96.2 96.0 0.88 630 8.4 3.2 1■M1222-3BB76-6■■■ 1200 rpm, 6-pole 185 248 315 Δ 60.4 1473 94.9 95.6 95.4 0.81 250 8.9 2.7 1■M1222-3AC16-7■■■ 235 315 315 Δ 60.4 1870 95.3 95.7 95.6 0.81 320 9.7 3.1 1■M1222-3AC36-7■■■ 275 369 315 Δ 60.4 2189 95.3 95.7 95.8 0.83 360 9.3 2.8 1■M1222-3AC56-7■■■ 300 402 315 Δ 60.4 2388 95.5 95.7 95.9 0.83 400 9.7 3.0 1■M1222-3AC76-7■■■ 350 469 355 Δ 60.3 2786 95.2 95.7 95.2 0.83 465 11.9 3.6 1■M1222-3BC56-7■■■ 1■M1222-3BC76-7■■■ 370 496 355 Δ 60.2 2947 95.3 95.7 95.0 0.79 510 13.4 3.4 900 rpm, 6-pole 150 201 315 Δ 45.3 1592 94.5 95.1 94.8 0.73 225 9.6 3.4 1■M1222-3AC16-8■■■ 185 248 315 Δ 45.3 1963 94.8 95.4 95.0 0.74 275 10.1 3.6 1■M1222-3AC36-8■■■ 220 295 315 Δ 45.4 2335 94.8 95.6 95.4 0.80 300 9.6 3.2 1■M1222-3AC56-8■■■ 245 329 315 Δ 45.4 2600 94.9 95.7 95.5 0.80 335 9.5 2.8 1■M1222-3AC76-8■■■ 280 375 355 Δ 45.3 2971 94.8 95.5 95.2 0.84 365 10.9 3.3 1■M1222-3BC56-8■■■ 300 402 355 Δ 45.3 3184 94.9 95.6 95.2 0.83 395 11.4 3.1 1■M1222-3BC76-8■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC76-8■■■ Prated 4/18 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.M1212-3AB16-5... 1.M1212-3AB36-5... 1.M1212-3AB56-5... 1.M1212-3AB76-5... 1260 1440 1620 1780 1310 1490 1670 1830 3.5 4.4 5.1 5.9 79 79 79 79 94 94 94 94 3600 3600 3600 3600 1XB7 730 1XB7 730 1XB7 730 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 250 320 400 400 1.M1212-3BB56-1... 1.M1212-3BB76-1... 2220 2350 2280 2410 8.4 9 79 79 95 95 3300 3300 1XB7 731 1XB7 731 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 452 560 1.M1212-3AB16-6... 1.M1212-3AB36-6... 1.M1212-3AB56-6... 1.M1212-3AB76-6... 1.M1212-3BB56-6... 1.M1212-3BB76-6... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 2750 2750 2750 2750 2200 2200 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 320 400 400 452 560 710 1.M1212-3AC16-7... 1.M1212-3AC36-7... 1.M1212-3AC56-7... 1.M1212-3AC76-7... 1.M1212-3BC56-7... 1.M1212-3BC76-7... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 250 320 400 400 452 560 1.M1212-3AC16-8... 1.M1212-3AC36-8... 1.M1212-3AC56-8... 1.M1212-3AC76-8... 1.M1212-3BC56-8... 1.M1212-3BC76-8... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 6SL3710-7LG32-2AA3 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 208 250 320 320 400 400 1.M1222-3AB16-5... 1.M1222-3AB36-5... 1.M1222-3AB56-5... 1.M1222-3AB76-5... 1260 1440 1620 1780 1310 1490 1670 1830 3.5 4.4 5.1 5.9 79 79 79 79 94 94 94 94 3600 3600 3600 3600 1XB7 730 1XB7 730 1XB7 730 1XB7 731 6SL3710-1GF33-3AA3 6SL3710-1GF33-3AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-1AA3 320 320 400 400 1.M1222-3BB56-1... 1.M1222-3BB76-1... 2220 2350 2280 2410 8.4 9 79 79 95 95 3300 3300 1XB7 731 1XB7 731 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 560 560 1.M1222-3AB16-6... 1.M1222-3AB36-6... 1.M1222-3AB56-6... 1.M1222-3AB76-6... 1.M1222-3BB56-6... 1.M1222-3BB76-6... 1260 1440 1620 1780 2220 2350 1310 1490 1670 1830 2280 2410 3.5 4.4 5.1 5.9 8.4 9 79 79 79 79 79 79 94 94 94 94 95 95 2750 2750 2750 2750 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GF33-3AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 320 400 452 560 710 710 1.M1222-3AC16-7... 1.M1222-3AC36-7... 1.M1222-3AC56-7... 1.M1222-3AC76-7... 1.M1222-3BC56-7... 1.M1222-3BC76-7... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GF32-6AA3 6SL3710-1GF33-3AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-1AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 250 320 400 400 560 560 1.M1222-3AC16-8... 1.M1222-3AC36-8... 1.M1222-3AC56-8... 1.M1222-3AC76-8... 1.M1222-3BC56-8... 1.M1222-3BC76-8... 1290 1460 1650 1750 2220 2370 1340 1510 1700 1800 2270 2420 5.9 7.3 8.3 9.1 14.6 16.1 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-1GF32-6AA3 6SL3710-1GF33-3AA3 6SL3710-1GF33-3AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-1AA3 250 320 320 400 400 400 Siemens D 81.8 · 04/2014 4 4/19 © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 575 V, 60 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LM1/1MM1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V 1800 rpm, 4-pole 4 125 168 315 Δ 60.2 663 95.3 95.8 94.7 0.74 166 13.8 5.9 1■M1213-3AB16-6■■■ 265 355 315 Δ 60.3 1407 95.7 96.2 95.9 0.83 315 11.2 4.2 1■M1213-3AB36-6■■■ 345 463 315 Δ 60.4 1830 95.5 96.2 96.0 0.87 390 9.7 3.5 1■M1213-3AB56-6■■■ 395 530 315 Δ 60.4 2097 95.8 96.4 96.2 0.86 450 11.4 3.5 1■M1213-3AB76-6■■■ 510 684 355 Δ 60.4 2706 95.7 96.4 96.3 0.87 580 8.5 3.3 1■M1213-3BB56-6■■■ 560 751 355 Δ 60.4 2973 95.9 96.6 96.4 0.86 640 9.3 3.3 1■M1213-3BB76-6■■■ 1200 rpm, 6-pole 210 282 315 Δ 60.4 1672 95.1 95.9 95.7 0.80 260 8.9 2.8 1■M1213-3AC16-7■■■ 250 335 315 Δ 60.4 1990 95.3 96.0 95.9 0.81 305 9.3 2.9 1■M1213-3AC36-7■■■ 285 382 315 Δ 60.4 2268 95.4 96.1 96.1 0.83 340 8.8 2.7 1■M1213-3AC56-7■■■ 315 422 315 Δ 60.4 2507 95.5 96.2 96.1 0.83 375 9.0 2.8 1■M1213-3AC76-7■■■ 395 530 355 Δ 60.3 3144 95.6 96.2 95.9 0.80 485 11.2 3.1 1■M1213-3BC56-7■■■ 435 583 355 Δ 60.3 3462 95.7 96.3 96.1 0.83 520 10.8 2.9 1■M1213-3BC76-7■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V 1800 rpm, 4-pole 125 168 315 Δ 60.3 663 95.3 95.8 95.0 0.78 177 13.3 5.4 1■M1223-3AB16-6■■■ 265 355 315 Δ 60.3 1407 95.6 96.2 96.0 0.84 345 10.9 4.1 1■M1223-3AB36-6■■■ 340 456 315 Δ 60.4 1804 95.5 96.2 96.0 0.88 420 9.8 3.5 1■M1223-3AB56-6■■■ 400 536 315 Δ 60.3 2123 95.8 96.4 96.2 0.85 510 11.5 3.5 1■M1223-3AB76-6■■■ 505 677 355 Δ 60.4 2679 95.8 96.5 96.3 0.86 640 8.9 3.4 1■M1223-3BB56-6■■■ 530 711 355 Δ 60.4 2812 95.7 96.4 96.4 0.88 660 8.0 3.0 1■M1223-3BB76-6■■■ 1200 rpm, 6-pole 175 235 315 Δ 60.4 1393 95.0 95.8 95.6 0.81 235 9.4 2.9 1■M1223-3AC16-7■■■ 250 335 315 Δ 60.4 1990 95.3 96.0 95.9 0.81 335 9.2 2.9 1■M1223-3AC36-7■■■ 285 382 315 Δ 60.4 2269 95.4 96.1 96.1 0.83 375 8.8 2.7 1■M1223-3AC56-7■■■ 315 422 315 Δ 60.4 2507 95.5 96.2 96.1 0.83 415 9.3 2.9 1■M1223-3AC76-7■■■ 385 516 355 Δ 60.3 3064 95.6 96.2 96.0 0.83 510 10.8 3.2 1■M1223-3BC56-7■■■ 405 543 355 Δ 60.3 3226 95.7 96.3 95.9 0.79 560 12.2 3.1 1■M1223-3BC76-7■■■ For versions, see Article No. supplements and special versions 4/20 Siemens D 81.8 · 04/2014 1■M1223-3AC76-7■■■ © Siemens AG 2014 Self-ventilated motors — enclosed version 1LM1/1MM1 motors for converter-fed operation Line voltage 575 V, 60 Hz Premium Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.M1213-3AB16-6... 1260 1310 3.5 79 94 3000 1XB7 730 6SL3710-7LG31-8AA3 170 1.M1213-3AB36-6... 1440 1490 4.4 79 94 3000 1XB7 730 6SL3710-7LG33-3AA3 320 1.M1213-3AB56-6... 1620 1670 5.1 79 94 2750 1XB7 731 6SL3710-7LG34-1AA3 400 1.M1213-3AB76-6... 1780 1830 5.9 79 94 2750 1XB7 731 6SL3710-7LG34-7AA3 452 1.M1213-3BB56-6... 2220 2280 8.4 79 95 2200 1XB7 731 6SL3710-7LG37-4AA3 710 1.M1213-3BB76-6... 2350 2410 9 79 95 2200 1XB7 740 6SL3710-7LG37-4AA3 710 1.M1213-3AC16-7... 1290 1340 5.9 79 94 2500 1XB7 730 6SL3710-7LG33-3AA3 320 1.M1213-3AC36-7... 1460 1510 7.3 79 94 2500 1XB7 730 6SL3710-7LG33-3AA3 320 1.M1213-3AC56-7... 1650 1700 8.3 79 94 2500 1XB7 730 6SL3710-7LG34-1AA3 400 1.M1213-3AC76-7... 1750 1800 9.1 79 94 2500 1XB7 731 6SL3710-7LG34-1AA3 400 1.M1213-3BC56-7... 2220 2270 14.6 79 95 2200 1XB7 731 6SL3710-7LG35-8AA3 560 1.M1213-3BC76-7... 2370 2420 16.1 79 95 2200 1XB7 731 6SL3710-7LG35-8AA3 560 1.M1223-3AB16-6... 1260 1310 3.5 79 94 3000 1XB7 730 6SL3710-1GF32-2AA3 208 1.M1223-3AB36-6... 1440 1490 4.4 79 94 3000 1XB7 730 6SL3710-1GF34-1AA3 400 1.M1223-3AB56-6... 1620 1670 5.1 79 94 2750 1XB7 731 6SL3710-1GF34-7AA3 452 1.M1223-3AB76-6... 1780 1830 5.9 79 94 2750 1XB7 731 6SL3710-1GF35-8AA3 560 1.M1223-3BB56-6... 2220 2280 8.4 79 95 2200 1XB7 740 6SL3710-1GF37-4AA3 710 1.M1223-3BB76-6... 2350 2410 9 79 95 2200 1XB7 740 6SL3710-1GF37-4AA3 710 1.M1223-3AC16-7... 1290 1340 5.9 79 94 2500 1XB7 730 6SL3710-1GF32-6AA3 250 1.M1223-3AC36-7... 1460 1510 7.3 79 94 2500 1XB7 730 6SL3710-1GF34-1AA3 400 1.M1223-3AC56-7... 1650 1700 8.3 79 94 2500 1XB7 731 6SL3710-1GF34-1AA3 400 1.M1223-3AC76-7... 1750 1800 9.1 79 94 2500 1XB7 731 6SL3710-1GF34-7AA3 452 1.M1223-3BC56-7... 2220 2270 14.6 79 95 2200 1XB7 731 6SL3710-1GF35-8AA3 560 1.M1223-3BC76-7... 2370 2420 16.1 79 95 2200 1XB7 731 6SL3710-1GF35-8AA3 560 Siemens D 81.8 · 04/2014 4 4/21 © Siemens AG 2014 Self-ventilated motors — enclosed version Dimensions 1LM1/1MM1 motors ■ Dimensional drawings IM B3 type of construction For terminal box dimensions, see Page 4/24 L LL BE HB' HK HC GA HD AC ØD F HB AG 4 AD BC H HA EB DB BA E G_D081_XX_00416 C ØK B BB Ø K' AA A AB IM B35 and IM V1 types of construction For flange dimensions, see Page 4/23 (Z = the number of retaining holes), For terminal box dimensions, see Page 4/24 L LL HC HB' HK HH BE AG AD LM HB ZxS GA AQ AC ØP ØN ØD F E DB G_D081_XX_00417 BA LA LE C Frame No. of size poles Motor type 315 1.M12..-3A.1.-.... 1.M12..-3A.3.-.... 4, 6 4, 6 1.M12..-3A.5.-.... 1.M12..-3A.7.-.... ØK Ø K' B BB AA AB AC AQ B BA BB C H HA K K' L LM D 560 120 680 630 670 630 180 780 180 315 28 28 35 1470 1615 85 ● 560 120 680 630 670 630 180 780 200 315 28 28 35 1490 1635 95 560 120 680 630 670 835 180 985 180 315 28 28 35 1610 1755 85 DB E EB F GA M20 170 140 22 90 M24 170 140 25 100 M20 170 140 22 90 ● 560 120 680 630 670 835 180 985 200 315 28 28 35 1630 1775 95 M24 170 140 25 100 630 150 780 710 750 800 220 980 200 355 35 35 42 1730 1900 95 M24 170 140 25 100 ● 630 150 780 710 750 800 220 980 224 355 35 35 42 1795 1965 100 M24 210 180 28 106 ● Bearing design for increased cantilever forces, for type of construction IM B3 only. 4/22 AA A AB Dimension designation acc. to IEC A 1.M12..-3A.5.-.... 1.M12..-3A.7.-.... 355 M H HA EB HD T Siemens D 81.8 · 04/2014 © Siemens AG 2014 Self-ventilated motors — enclosed version Dimensions Flanges G_D081_XX_00026 ■ Dimensional drawings (Z = the number of retaining holes) 4 Flange with through holes Motor type Frame size No. of poles Type of construction Flange type Dimension designation acc. to IEC LA 1LM1/1MM1 315 355 4, 6 4, 6 IM B35, IM V1 IM B35, IM V1 LE M N P S T Z Flange 29 170 740 680 800 22 6 8 Flange (optional) 22 170 600 550 660 22 6 8 Flange 29 170 840 780 900 22 6 8 Flange (optional) 22 170 600 550 660 22 6 8 Siemens D 81.8 · 04/2014 4/23 © Siemens AG 2014 Self-ventilated motors — enclosed version Dimensions Terminal boxes ■ Dimensional drawings LL BE HB' HK HC AG1 IM B3 type of construction HD HB AG AD BC 4 G_D081_XX_00426 LL HC HB' HK HH AG1 IM B35 and IM V1 types of construction HD HB AG AD BE G_D081_XX_00427 Motor type Frame size No. of poles Terminal box Dimension designation acc. to IEC AD AG AG1 BC BE HB HB' HH HC HD HK LL 1LM1/ 1MM1 315 4, 6 1XB7 730 710 575 – 115 – 890 310 295 180 1025 255 345 1XB7 731 710 575 – 115 115 890 310 295 180 1025 255 345 1XB7 740 800 615 60 115 150 930 365 295 235 1110 335 425 GT640 655 555 – 115 110 870 225 295 155 970 170 310 1XB1 621 705 585 – 115 150 900 305 295 165 1020 250 330 1XB1 631 775 640 – 115 100 955 400 295 175 1090 320 555 1XB7 730 750 615 – 100 – 970 310 300 180 1105 255 345 1XB7 731 750 615 – 100 115 970 310 300 180 1105 255 345 1XB7 740 840 655 60 100 150 1010 365 300 235 1190 340 425 GT640 695 595 – 100 110 950 225 300 155 1050 170 310 1XB1 621 745 625 – 100 150 980 305 300 165 1100 250 330 1XB1 631 815 680 – 100 100 1035 400 300 175 1170 320 555 355 4/24 4, 6 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors – enclosed version 5/2 5 5/2 5/2 5/4 5/6 5/8 5/8 5/10 5/12 5/14 5/14 5/16 5/18 5/20 5/20 5/22 5/24 5/26 5/26 5/28 5/30 1LQ1/1MQ1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency – low noise High Efficiency – increased output Premium Efficiency Line voltage 500 V, 50 Hz High Efficiency – low noise High Efficiency – increased output Premium Efficiency Line voltage 690 V, 50 Hz High Efficiency – low noise High Efficiency – increased output Premium Efficiency Line voltage 460 V, 60 Hz High Efficiency – low noise High Efficiency – increased output Premium Efficiency Line voltage 575 V, 60 Hz High Efficiency – low noise High Efficiency – increased output Premium Efficiency 5/32 5/32 5/32 5/33 5/34 5/35 Dimensions 1LQ1/1MQ1 motors • Radially mounted equipment unit • Axially mounted equipment unit Flanges Terminal boxes Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency – low noise ■ Selection and ordering data 5 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V 3000 rpm, 4-pole 255 342 315 Δ 100.7 812 94.7 95.2 94.7 0.89 410 6.1 2.1 1■Q1212-3AB11-1■■■ 1■Q1212-3AB31-1■■■ 320 429 315 Δ 100.6 1019 95.2 95.7 95.2 0.90 500 6.7 2.2 360 483 315 Δ 100.6 1146 95.4 95.9 95.5 0.90 570 7.0 2.3 1■Q1212-3AB51-1■■■ 415 557 315 Δ 100.6 1321 95.7 96.1 95.7 0.91 640 7.6 2.5 1■Q1212-3AB71-1■■■ 1■Q1212-3BB51-1■■■ 455 610 355 Δ 100.5 1449 95.7 96.3 95.9 0.89 720 6.5 2.3 475 637 355 Δ 100.6 1513 95.7 96.3 96.0 0.89 750 5.8 2.1 1■Q1212-3BB71-1■■■ 1500 rpm, 4-pole 245 329 315 Δ 50.5 1560 94.7 95.6 95.8 0.87 400 7.1 2.6 1■Q1212-3AB11-2■■■ 320 429 315 Δ 50.5 2037 95.1 95.9 96.1 0.88 510 8.1 2.9 1■Q1212-3AB31-2■■■ 355 476 315 Δ 50.5 2260 95.2 95.9 96.2 0.89 560 8.3 2.9 1■Q1212-3AB51-2■■■ 405 543 315 Δ 50.5 2579 95.3 96.2 96.3 0.90 640 8.2 2.9 1■Q1212-3AB71-2■■■ 430 577 355 Δ 50.4 2738 95.6 96.5 96.6 0.88 690 7.4 2.9 1■Q1212-3BB51-2■■■ 475 637 355 Δ 50.4 3024 95.7 96.6 96.6 0.88 760 8.3 3.2 1■Q1212-3BB71-2■■■ 1000 rpm, 6-pole 215 288 315 Δ 50.5 2054 94.6 95.5 95.7 0.81 380 7.5 2.4 1■Q1212-3AC11-3■■■ 265 355 315 Δ 50.5 2532 94.8 95.7 95.9 0.82 460 7.6 2.4 1■Q1212-3AC31-3■■■ 305 409 315 Δ 50.5 2914 94.9 95.7 96.0 0.84 510 7.5 2.3 1■Q1212-3AC51-3■■■ 1■Q1212-3AC71-3■■■ 340 456 315 Δ 50.4 3248 95.1 95.7 96.0 0.83 580 8.0 2.3 380 510 355 Δ 50.4 3630 95.1 96.0 95.9 0.86 630 9.1 2.7 1■Q1212-3BC51-3■■■ 425 570 355 Δ 50.3 4059 95.3 96.1 95.9 0.84 720 10.1 2.4 1■Q1212-3BC71-3■■■ 750 rpm, 6-pole 165 221 315 Δ 38.0 2102 93.7 94.8 95.0 0.79 300 7.4 2.6 1■Q1212-3AC11-4■■■ 215 288 315 Δ 38.0 2739 93.9 95.0 95.3 0.81 380 7.1 2.4 1■Q1212-3AC31-4■■■ 245 329 315 Δ 38.0 3122 93.9 95.1 95.5 0.84 415 6.8 2.2 1■Q1212-3AC51-4■■■ 275 369 315 Δ 38.0 3503 94.0 95.2 95.5 0.84 465 6.8 2.1 1■Q1212-3AC71-4■■■ 315 422 355 Δ 37.9 4013 94.0 95.1 95.4 0.87 520 7.6 2.5 1■Q1212-3BC51-4■■■ 350 469 355 Δ 37.9 4458 94.2 95.3 95.5 0.87 570 7.9 2.2 1■Q1212-3BC71-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V 3000 rpm, 4-pole 245 329 315 Δ 100.6 780 94.7 95.1 94.6 0.89 440 6.3 2.1 1■Q1222-3AB11-1■■■ 1■Q1222-3AB31-1■■■ 310 416 315 Δ 100.6 987 95.2 95.7 95.2 0.90 550 7.1 2.4 355 476 315 Δ 100.5 1130 95.5 95.9 95.4 0.90 620 7.8 2.6 1■Q1222-3AB51-1■■■ 375 503 315 Δ 100.7 1194 95.4 96.0 95.6 0.91 650 6.6 2.2 1■Q1222-3AB71-1■■■ 445 597 355 Δ 100.4 1417 95.8 96.2 95.7 0.89 790 7.7 2.8 1■Q1222-3BB51-1■■■ 465 624 355 Δ 100.5 1480 95.8 96.3 95.9 0.89 820 6.9 2.5 1■Q1222-3BB71-1■■■ 1500 rpm, 4-pole 250 335 315 Δ 50.5 1592 94.9 95.7 95.8 0.85 465 7.7 2.9 1■Q1222-3AB11-2■■■ 315 422 315 Δ 50.5 2006 95.1 95.9 96.1 0.88 570 8.0 2.9 1■Q1222-3AB31-2■■■ 355 476 315 Δ 50.5 2260 95.3 95.9 96.2 0.89 630 8.3 3.0 1■Q1222-3AB51-2■■■ 405 543 315 Δ 50.5 2579 95.4 96.3 96.4 0.89 720 8.5 2.9 1■Q1222-3AB71-2■■■ 430 577 355 Δ 50.4 2738 95.6 96.5 96.6 0.88 770 7.8 3.0 1■Q1222-3BB51-2■■■ 480 644 355 Δ 50.4 3059 95.9 96.6 96.6 0.87 870 8.9 3.2 1■Q1222-3BB71-2■■■ 1000 rpm, 6-pole 215 288 315 Δ 50.5 2054 94.5 95.5 95.7 0.81 420 7.3 2.3 1■Q1222-3AC11-3■■■ 270 362 315 Δ 50.5 2580 94.8 95.7 95.9 0.82 520 7.6 2.4 1■Q1222-3AC31-3■■■ 305 409 315 Δ 50.5 2914 95.0 95.7 96.0 0.83 580 7.8 2.4 1■Q1222-3AC51-3■■■ 1■Q1222-3AC71-3■■■ 345 463 315 Δ 50.5 3296 95.0 95.7 96.1 0.84 650 7.4 2.2 380 510 355 Δ 50.3 3630 95.2 96.0 95.8 0.84 720 9.8 2.7 1■Q1222-3BC51-3■■■ 415 557 355 Δ 50.3 3964 95.3 96.1 95.9 0.85 770 10.0 2.5 1■Q1222-3BC71-3■■■ 750 rpm, 6-pole 180 241 315 Δ 38.0 2293 93.6 94.8 95.1 0.80 360 7.0 2.4 1■Q1222-3AC11-4■■■ 215 288 315 Δ 38.0 2739 94.0 95.1 95.3 0.80 430 7.5 2.6 1■Q1222-3AC31-4■■■ 245 329 315 Δ 38.0 3121 94.0 95.2 95.4 0.82 475 7.3 2.4 1■Q1222-3AC51-4■■■ 270 362 315 Δ 38.0 3440 94.0 95.2 95.5 0.84 510 6.9 2.2 1■Q1222-3AC71-4■■■ 315 422 355 Δ 37.9 4013 94.0 95.1 95.4 0.87 580 7.6 2.5 1■Q1222-3BC51-4■■■ 350 469 355 Δ 37.9 4458 94.2 95.3 95.5 0.87 640 8.1 2.2 1■Q1222-3BC71-4■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC71-4■■■ Prated 5/2 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency – low noise Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1212-3AB11-1... 1.Q1212-3AB31-1... 1.Q1212-3AB51-1... 1.Q1212-3AB71-1... 1.Q1212-3BB51-1... 1.Q1212-3BB71-1... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 477 590 590 725 725 820 1.Q1212-3AB11-2... 1.Q1212-3AB31-2... 1.Q1212-3AB51-2... 1.Q1212-3AB71-2... 1.Q1212-3BB51-2... 1.Q1212-3BB71-2... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 477 590 590 725 725 820 1.Q1212-3AC11-3... 1.Q1212-3AC31-3... 1.Q1212-3AC51-3... 1.Q1212-3AC71-3... 1.Q1212-3BC51-3... 1.Q1212-3BC71-3... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 477 477 590 590 725 725 1.Q1212-3AC11-4... 1.Q1212-3AC31-4... 1.Q1212-3AC51-4... 1.Q1212-3AC71-4... 1.Q1212-3BC51-4... 1.Q1212-3BC71-4... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LE33-1AA3 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 302 477 477 477 590 590 1.Q1222-3AB11-1... 1.Q1222-3AB31-1... 1.Q1222-3AB51-1... 1.Q1222-3AB71-1... 1.Q1222-3BB51-1... 1.Q1222-3BB71-1... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE38-4AA3 477 590 725 725 820 820 1.Q1222-3AB11-2... 1.Q1222-3AB31-2... 1.Q1222-3AB51-2... 1.Q1222-3AB71-2... 1.Q1222-3BB51-2... 1.Q1222-3BB71-2... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 477 590 725 725 820 960 1.Q1222-3AC11-3... 1.Q1222-3AC31-3... 1.Q1222-3AC51-3... 1.Q1222-3AC71-3... 1.Q1222-3BC51-3... 1.Q1222-3BC71-3... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 477 590 590 725 725 820 1.Q1222-3AC11-4... 1.Q1222-3AC31-4... 1.Q1222-3AC51-4... 1.Q1222-3AC71-4... 1.Q1222-3BC51-4... 1.Q1222-3BC71-4... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 370 477 477 590 590 725 Siemens D 81.8 · 04/2014 5 5/3 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency – increased output ■ Selection and ordering data 5 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V 3000 rpm, 4-pole 280 375 315 Δ 100.7 892 94.6 95.2 94.8 0.89 450 5.6 1.9 1■Q1312-3AB11-1■■■ 1■Q1312-3AB31-1■■■ 355 476 315 Δ 100.7 1130 95.1 95.7 95.4 0.90 560 6.0 2.0 400 536 315 Δ 100.7 1274 95.3 95.9 95.6 0.90 630 6.3 2.1 1■Q1312-3AB51-1■■■ 460 617 315 Δ 100.6 1465 95.6 96.1 95.8 0.91 710 6.8 2.2 1■Q1312-3AB71-1■■■ 1■Q1312-3BB51-1■■■ 495 664 355 Δ 100.6 1576 95.7 96.3 96.0 0.89 780 6.0 2.1 510 684 355 Δ 100.6 1624 95.6 96.3 96.1 0.89 810 5.4 1.9 1■Q1312-3BB71-1■■■ 1500 rpm, 4-pole 265 355 315 Δ 50.6 1688 94.4 95.4 95.7 0.87 435 6.5 2.4 1■Q1312-3AB11-2■■■ 345 463 315 Δ 50.5 2197 94.9 95.8 96.0 0.88 560 7.4 2.7 1■Q1312-3AB31-2■■■ 380 510 315 Δ 50.5 2420 95.0 95.9 96.1 0.89 600 7.7 2.7 1■Q1312-3AB51-2■■■ 435 583 315 Δ 50.5 2770 95.1 96.0 96.3 0.90 680 7.7 2.7 1■Q1312-3AB71-2■■■ 470 630 355 Δ 50.5 2993 95.4 96.4 96.5 0.89 740 6.9 2.6 1■Q1312-3BB51-2■■■ 515 691 355 Δ 50.4 3279 95.6 96.5 96.6 0.88 820 7.7 2.9 1■Q1312-3BB71-2■■■ 1000 rpm, 6-pole 235 315 315 Δ 50.5 2246 94.2 95.3 95.5 0.81 415 6.8 2.2 1■Q1312-3AC11-3■■■ 290 389 315 Δ 50.5 2771 94.5 95.5 95.7 0.83 495 7.0 2.2 1■Q1312-3AC31-3■■■ 335 449 315 Δ 50.6 3201 94.6 95.6 95.9 0.84 570 6.7 2.1 1■Q1312-3AC51-3■■■ 1■Q1312-3AC71-3■■■ 375 503 315 Δ 50.5 3583 94.8 95.7 95.9 0.84 640 7.2 2.1 405 543 355 Δ 50.4 3870 95.0 95.9 95.9 0.86 670 8.6 2.6 1■Q1312-3BC51-3■■■ 455 610 355 Δ 50.3 4346 95.2 96.0 95.9 0.85 760 9.6 2.3 1■Q1312-3BC71-3■■■ 750 rpm, 6-pole 190 255 315 Δ 38.0 2420 93.0 94.3 94.8 0.80 340 6.5 2.2 1■Q1312-3AC11-4■■■ 235 315 315 Δ 38.0 2994 93.4 94.7 95.1 0.82 410 6.6 2.2 1■Q1312-3AC31-4■■■ 270 362 315 Δ 38.1 3441 93.4 94.7 95.2 0.84 460 6.1 2.0 1■Q1312-3AC51-4■■■ 300 402 315 Δ 38.1 3823 93.6 94.9 95.3 0.84 510 6.2 1.9 1■Q1312-3AC71-4■■■ 330 443 355 Δ 37.9 4204 93.8 95.0 95.3 0.87 540 7.3 2.4 1■Q1312-3BC51-4■■■ 370 496 355 Δ 37.9 4713 94.0 95.2 95.4 0.87 610 7.4 2.1 1■Q1312-3BC71-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V 3000 rpm, 4-pole 275 369 315 Δ 100.7 876 94.6 95.1 94.8 0.89 495 5.6 1.9 1■Q1322-3AB11-1■■■ 1■Q1322-3AB31-1■■■ 350 469 315 Δ 100.7 1114 95.2 95.7 95.4 0.90 620 6.3 2.1 395 530 315 Δ 100.6 1258 95.4 95.9 95.6 0.90 700 6.9 2.3 1■Q1322-3AB51-1■■■ 415 557 315 Δ 100.7 1322 95.3 95.9 95.7 0.91 720 6.0 2.0 1■Q1322-3AB71-1■■■ 490 657 355 Δ 100.5 1560 95.8 96.3 95.9 0.89 870 7.0 2.5 1■Q1322-3BB51-1■■■ 510 684 355 Δ 100.5 1624 95.8 96.4 96.1 0.89 900 6.3 2.3 1■Q1322-3BB71-1■■■ 1500 rpm, 4-pole 270 362 315 Δ 50.5 1719 94.6 95.5 95.7 0.86 500 7.1 2.7 1■Q1322-3AB11-2■■■ 340 456 315 Δ 50.5 2165 94.8 95.8 96.0 0.88 610 7.5 2.7 1■Q1322-3AB31-2■■■ 385 516 315 Δ 50.5 2452 95.0 96.0 96.1 0.89 680 7.7 2.7 1■Q1322-3AB51-2■■■ 445 597 315 Δ 50.5 2833 95.1 96.1 96.3 0.90 780 7.9 2.6 1■Q1322-3AB71-2■■■ 475 637 355 Δ 50.5 3025 95.4 96.4 96.5 0.89 840 7.1 2.7 1■Q1322-3BB51-2■■■ 535 717 355 Δ 50.4 3406 95.7 96.6 96.6 0.88 960 8.1 2.9 1■Q1322-3BB71-2■■■ 1000 rpm, 6-pole 235 315 315 Δ 50.6 2246 94.2 95.2 95.5 0.82 455 6.7 2.1 1■Q1322-3AC11-3■■■ 295 396 315 Δ 50.5 2819 94.5 95.5 95.8 0.83 570 6.9 2.2 1■Q1322-3AC31-3■■■ 335 449 315 Δ 50.5 3201 94.6 95.7 95.9 0.83 640 7.0 2.2 1■Q1322-3AC51-3■■■ 1■Q1322-3AC71-3■■■ 380 510 315 Δ 50.6 3631 94.7 95.7 96.0 0.85 710 6.7 2.0 410 550 355 Δ 50.4 3917 95.1 95.9 95.8 0.85 760 9.3 2.5 1■Q1322-3BC51-3■■■ 440 590 355 Δ 50.3 4203 95.2 96.0 95.9 0.85 820 9.4 2.4 1■Q1322-3BC71-3■■■ 750 rpm, 6-pole 195 261 315 Δ 38.1 2486 93.2 94.5 94.9 0.80 390 6.5 2.2 1■Q1322-3AC11-4■■■ 240 322 315 Δ 38.0 3059 93.5 94.7 95.1 0.81 475 6.7 2.3 1■Q1322-3AC31-4■■■ 270 362 315 Δ 38.0 3440 93.6 94.8 95.2 0.83 520 6.6 2.2 1■Q1322-3AC51-4■■■ 295 396 315 Δ 38.1 3759 93.6 94.8 95.3 0.84 560 6.3 2.0 1■Q1322-3AC71-4■■■ 330 443 355 Δ 37.9 4204 93.9 95.0 95.3 0.87 610 7.2 2.4 1■Q1322-3BC51-4■■■ 370 496 355 Δ 37.9 4714 94.1 95.2 95.4 0.87 680 7.7 2.1 1■Q1322-3BC71-4■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC71-4■■■ Prated 5/4 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency – increased output Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1312-3AB11-1... 1.Q1312-3AB31-1... 1.Q1312-3AB51-1... 1.Q1312-3AB71-1... 1.Q1312-3BB51-1... 1.Q1312-3BB71-1... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE38-4AA3 477 590 725 725 820 820 1.Q1312-3AB11-2... 1.Q1312-3AB31-2... 1.Q1312-3AB51-2... 1.Q1312-3AB71-2... 1.Q1312-3BB51-2... 1.Q1312-3BB71-2... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE38-4AA3 477 590 725 725 820 820 1.Q1312-3AC11-3... 1.Q1312-3AC31-3... 1.Q1312-3AC51-3... 1.Q1312-3AC71-3... 1.Q1312-3BC51-3... 1.Q1312-3BC71-3... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 477 590 590 725 725 820 1.Q1312-3AC11-4... 1.Q1312-3AC31-4... 1.Q1312-3AC51-4... 1.Q1312-3AC71-4... 1.Q1312-3BC51-4... 1.Q1312-3BC71-4... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-7LE33-8AA3 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 370 477 477 590 590 725 1.Q1322-3AB11-1... 1.Q1322-3AB31-1... 1.Q1322-3AB51-1... 1.Q1322-3AB71-1... 1.Q1322-3BB51-1... 1.Q1322-3BB71-1... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE41-0AA3 6SL3710-1GE41-0AA3 590 725 725 725 960 960 1.Q1322-3AB11-2... 1.Q1322-3AB31-2... 1.Q1322-3AB51-2... 1.Q1322-3AB71-2... 1.Q1322-3BB51-2... 1.Q1322-3BB71-2... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-1GE41-0AA3 590 725 725 820 960 960 1.Q1322-3AC11-3... 1.Q1322-3AC31-3... 1.Q1322-3AC51-3... 1.Q1322-3AC71-3... 1.Q1322-3BC51-3... 1.Q1322-3BC71-3... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE38-4AA3 477 590 725 725 820 820 1.Q1322-3AC11-4... 1.Q1322-3AC31-4... 1.Q1322-3AC51-4... 1.Q1322-3AC71-4... 1.Q1322-3BC51-4... 1.Q1322-3BC71-4... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 477 477 590 590 725 725 Siemens D 81.8 · 04/2014 5 5/5 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 400 V, 50 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V 1500 rpm, 4-pole 5 210 282 315 Δ 50.5 1337 95.1 96.0 96.0 0.86 345 8.3 3.1 1■Q1213-3AB11-2■■■ 325 436 315 Δ 50.5 2070 95.1 96.0 96.2 0.88 520 7.9 2.9 1■Q1213-3AB31-2■■■ 360 483 315 Δ 50.5 2292 95.2 96.2 96.3 0.89 570 8.1 2.9 1■Q1213-3AB51-2■■■ 415 557 315 Δ 50.5 2643 95.3 96.3 96.5 0.90 650 8.1 2.8 1■Q1213-3AB71-2■■■ 445 597 355 Δ 50.5 2834 95.7 96.6 96.8 0.88 710 7.2 2.8 1■Q1213-3BB51-2■■■ 495 664 355 Δ 50.4 3152 95.9 96.8 96.9 0.88 790 8.0 3.1 1■Q1213-3BB71-2■■■ 1000 rpm, 6-pole 195 261 315 Δ 50.4 1863 94.8 95.8 95.8 0.79 350 8.1 2.6 1■Q1213-3AC11-3■■■ 270 362 315 Δ 50.5 2580 94.8 95.8 96.0 0.82 465 7.4 2.4 1■Q1213-3AC31-3■■■ 310 416 315 Δ 50.5 2962 94.9 95.9 96.1 0.84 520 7.3 2.3 1■Q1213-3AC51-3■■■ 345 463 315 Δ 50.5 3296 95.1 96.1 96.2 0.83 590 7.8 2.2 1■Q1213-3AC71-3■■■ 400 536 355 Δ 50.4 3821 95.3 96.3 96.3 0.85 660 8.7 2.6 1■Q1213-3BC51-3■■■ 445 597 355 Δ 50.3 4250 95.6 96.4 96.4 0.83 760 9.6 2.3 1■Q1213-3BC71-3■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V 1500 rpm, 4-pole 225 302 315 Δ 50.4 1433 95.2 96.0 96.0 0.84 425 8.4 3.2 1■Q1223-3AB11-2■■■ 320 429 315 Δ 50.5 2038 95.1 96.0 96.2 0.88 580 7.9 2.9 1■Q1223-3AB31-2■■■ 365 489 315 Δ 50.5 2324 95.3 96.2 96.4 0.89 650 8.1 2.9 1■Q1223-3AB51-2■■■ 420 563 315 Δ 50.5 2674 95.4 96.3 96.5 0.90 740 8.3 2.8 1■Q1223-3AB71-2■■■ 445 597 355 Δ 50.4 2833 95.7 96.7 96.9 0.88 790 7.6 2.9 1■Q1223-3BB51-2■■■ 505 677 355 Δ 50.4 3215 96.0 96.9 97.0 0.87 910 8.5 3.1 1■Q1223-3BB71-2■■■ 1000 rpm, 6-pole 195 261 315 Δ 50.5 1863 94.8 95.7 95.9 0.80 385 7.9 2.6 1■Q1223-3AC11-3■■■ 275 369 315 Δ 50.5 2627 94.8 95.8 96.0 0.82 530 7.4 2.4 1■Q1223-3AC31-3■■■ 315 422 315 Δ 50.5 3010 94.9 95.9 96.1 0.83 600 7.5 2.4 1■Q1223-3AC51-3■■■ 350 469 315 Δ 50.5 3344 95.0 96.1 96.3 0.84 660 7.2 2.2 1■Q1223-3AC71-3■■■ 400 536 355 Δ 50.3 3821 95.4 96.3 96.3 0.83 760 9.3 2.6 1■Q1223-3BC51-3■■■ 435 583 355 Δ 50.3 4155 95.6 96.4 96.4 0.84 820 9.4 2.4 1■Q1223-3BC71-3■■■ For versions, see Article No. supplements and special versions 5/6 Siemens D 81.8 · 04/2014 1■M1223-3AC71-3■■■ © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 400 V, 50 Hz Premium Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1213-3AB11-2... 1310 1360 3.5 79 94.5 3000 1XB7 730 6SL3710-7LE33-8AA3 370 1.Q1213-3AB31-2... 1490 1540 4.4 79 94.5 3000 1XB7 731 6SL3710-7LE36-1AA3 590 1.Q1213-3AB51-2... 1670 1720 5 79 94.5 3000 1XB7 731 6SL3710-7LE36-1AA3 590 1.Q1213-3AB71-2... 1830 1880 5.8 79 94.5 3000 1XB7 740 6SL3710-7LE37-5AA3 725 1.Q1213-3BB51-2... 2300 2350 8.3 79 95 2600 1XB7 740 6SL3710-7LE37-5AA3 725 1.Q1213-3BB71-2... 2420 2480 8.9 79 95 2600 1XB7 740 6SL3710-7LE38-4AA3 820 1.Q1213-3AC11-3... 1340 1390 5.9 79 94.5 2600 1XB7 730 6SL3710-7LE33-8AA3 370 1.Q1213-3AC31-3... 1520 1570 7.2 79 94.5 2600 1XB7 731 6SL3710-7LE35-0AA3 477 1.Q1213-3AC51-3... 1700 1750 8.3 79 94.5 2600 1XB7 731 6SL3710-7LE36-1AA3 590 1.Q1213-3AC71-3... 1810 1860 9.1 79 94.5 2600 1XB7 731 6SL3710-7LE36-1AA3 590 1.Q1213-3BC51-3... 2290 2350 14.5 79 95 2500 1XB7 740 6SL3710-7LE37-5AA3 725 1.Q1213-3BC71-3... 2440 2490 16 79 95 2500 1XB7 740 6SL3710-7LE38-4AA3 820 1.Q1223-3AB11-2... 1310 1360 3.5 79 94.5 3000 1XB7 731 6SL3710-1GE35-0AA3 477 1.Q1223-3AB31-2... 1490 1540 4.4 79 94.5 3000 1XB7 731 6SL3710-1GE36-1AA3 590 1.Q1223-3AB51-2... 1670 1720 5 79 94.5 3000 1XB7 740 6SL3710-1GE37-5AA3 725 1.Q1223-3AB71-2... 1830 1880 5.8 79 94.5 3000 1XB7 740 6SL3710-1GE38-4AA3 820 1.Q1223-3BB51-2... 2300 2350 8.3 79 95 2600 1XB7 740 6SL3710-1GE38-4AA3 820 1.Q1223-3BB71-2... 2420 2480 8.9 79 95 2600 1XB7 740 6SL3710-1GE41-0AA3 960 1.Q1223-3AC11-3... 1340 1390 5.9 79 94.5 2600 1XB7 731 6SL3710-1GE35-0AA3 477 1.Q1223-3AC31-3... 1520 1570 7.2 79 94.5 2600 1XB7 731 6SL3710-1GE36-1AA3 590 1.Q1223-3AC51-3... 1700 1750 8.3 79 94.5 2600 1XB7 740 6SL3710-1GE37-5AA3 725 1.Q1223-3AC71-3... 1810 1860 9.1 79 94.5 2600 1XB7 740 6SL3710-1GE37-5AA3 725 1.Q1223-3BC51-3... 2290 2350 14.5 79 95 2500 1XB7 740 6SL3710-1GE38-4AA3 820 1.Q1223-3BC71-3... 2440 2490 16 79 95 2500 1XB7 740 6SL3710-1GE38-4AA3 820 Siemens D 81.8 · 04/2014 5 5/7 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency – low noise ■ Selection and ordering data 5 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V 3000 rpm, 4-pole 240 322 315 Δ 100.6 764 94.6 95.0 94.5 0.89 315 6.8 2.3 1■Q1212-3AB12-1■■■ 1■Q1212-3AB32-1■■■ 305 409 315 Δ 100.5 971 95.2 95.6 95.0 0.89 400 8.2 2.8 340 456 315 Δ 100.5 1082 95.4 95.8 95.3 0.90 440 8.5 2.8 1■Q1212-3AB52-1■■■ 365 489 315 Δ 100.6 1162 95.4 95.9 95.5 0.91 465 7.1 2.3 1■Q1212-3AB72-1■■■ 1■Q1212-3BB52-1■■■ 435 583 355 Δ 100.5 1385 95.7 96.1 95.7 0.89 560 7.5 2.7 455 610 355 Δ 100.5 1449 95.7 96.2 95.9 0.89 590 6.7 2.4 1■Q1212-3BB72-1■■■ 1500 rpm, 4-pole 225 302 315 Δ 50.5 1433 94.6 95.5 95.6 0.87 300 7.6 2.8 1■Q1212-3AB12-2■■■ 285 382 315 Δ 50.5 1815 94.9 95.8 96.0 0.88 375 8.0 2.9 1■Q1212-3AB32-2■■■ 330 443 315 Δ 50.4 2101 95.2 95.9 96.1 0.88 435 8.8 3.2 1■Q1212-3AB52-2■■■ 390 523 315 Δ 50.4 2483 95.5 96.3 96.3 0.87 520 9.8 3.0 1■Q1212-3AB72-2■■■ 410 550 355 Δ 50.4 2612 95.7 96.5 96.4 0.86 550 9.0 3.6 1■Q1212-3BB52-2■■■ 445 597 355 Δ 50.3 2835 95.8 96.5 96.4 0.85 600 9.9 3.5 1■Q1212-3BB72-2■■■ 1000 rpm, 6-pole 205 275 315 Δ 50.5 1959 94.6 95.5 95.6 0.81 295 7.9 2.5 1■Q1212-3AC12-3■■■ 245 329 315 Δ 50.4 2341 94.8 95.7 95.7 0.82 345 8.2 2.6 1■Q1212-3AC32-3■■■ 280 375 315 Δ 50.5 2675 94.7 95.7 95.8 0.84 385 7.7 2.4 1■Q1212-3AC52-3■■■ 1■Q1212-3AC72-3■■■ 305 409 315 Δ 50.4 2914 94.9 95.7 95.9 0.84 420 8.0 2.5 350 469 355 Δ 50.3 3343 95.1 95.7 95.7 0.85 475 10.0 3.0 1■Q1212-3BC52-3■■■ 385 516 355 Δ 50.3 3677 95.2 95.9 95.7 0.84 530 10.6 2.7 1■Q1212-3BC72-3■■■ 750 rpm, 6-pole 160 215 315 Δ 37.9 2038 93.5 94.6 94.8 0.78 240 7.6 2.6 1■Q1212-3AC12-4■■■ 195 261 315 Δ 37.9 2484 93.8 94.9 95.1 0.80 285 7.8 2.6 1■Q1212-3AC32-4■■■ 220 295 315 Δ 38.0 2803 93.7 94.9 95.3 0.84 305 7.3 2.4 1■Q1212-3AC52-4■■■ 250 335 315 Δ 38.0 3185 93.9 95.1 95.3 0.83 350 7.5 2.3 1■Q1212-3AC72-4■■■ 290 389 355 Δ 37.8 3694 94.2 95.2 95.2 0.85 400 9.1 2.7 1■Q1212-3BC52-4■■■ 320 429 355 Δ 37.9 4076 94.1 95.1 95.3 0.87 430 8.4 2.4 1■Q1212-3BC72-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V 3000 rpm, 4-pole 255 342 315 Δ 100.6 812 94.8 95.2 94.7 0.89 360 6.5 2.2 1■Q1222-3AB12-1■■■ 1■Q1222-3AB32-1■■■ 320 429 315 Δ 100.6 1019 95.2 95.7 95.2 0.90 445 6.7 2.2 355 476 315 Δ 100.6 1130 95.4 95.9 95.5 0.90 495 6.9 2.3 1■Q1222-3AB52-1■■■ 410 550 315 Δ 100.6 1305 95.6 96.1 95.7 0.91 560 7.2 2.3 1■Q1222-3AB72-1■■■ 445 597 355 Δ 100.6 1417 95.6 96.2 95.9 0.89 630 6.1 2.2 1■Q1222-3BB52-1■■■ 485 650 355 Δ 100.5 1544 95.8 96.3 95.9 0.89 680 7.4 2.6 1■Q1222-3BB72-1■■■ 1500 rpm, 4-pole 245 329 315 Δ 50.6 1560 94.6 95.6 95.8 0.87 355 6.8 2.5 1■Q1222-3AB12-2■■■ 325 436 315 Δ 50.5 2069 95.2 95.9 96.1 0.87 470 8.2 3.0 1■Q1222-3AB32-2■■■ 360 483 315 Δ 50.5 2292 95.3 95.9 96.2 0.89 510 8.3 3.0 1■Q1222-3AB52-2■■■ 405 543 315 Δ 50.5 2579 95.3 96.2 96.3 0.90 560 8.3 2.9 1■Q1222-3AB72-2■■■ 450 603 355 Δ 50.4 2868 95.8 96.6 96.5 0.86 650 9.0 3.5 1■Q1222-3BB52-2■■■ 475 637 355 Δ 50.4 3024 95.7 96.6 96.6 0.88 670 8.1 3.1 1■Q1222-3BB72-2■■■ 1000 rpm, 6-pole 210 282 315 Δ 50.5 2007 94.4 95.5 95.7 0.82 325 7.0 2.2 1■Q1222-3AC12-3■■■ 270 362 315 Δ 50.5 2579 94.9 95.7 95.9 0.82 415 7.7 2.5 1■Q1222-3AC32-3■■■ 305 409 315 Δ 50.5 2914 94.9 95.7 96.0 0.84 460 7.4 2.4 1■Q1222-3AC52-3■■■ 1■Q1222-3AC72-3■■■ 340 456 315 Δ 50.5 3248 95.1 95.7 96.1 0.83 510 7.8 2.3 380 510 355 Δ 50.4 3630 95.1 95.9 95.9 0.86 550 9.0 2.7 1■Q1222-3BC52-3■■■ 425 570 355 Δ 50.3 4060 95.3 96.1 95.9 0.85 630 9.5 2.4 1■Q1222-3BC72-3■■■ 750 rpm, 6-pole 170 228 315 Δ 38.0 2166 93.6 94.8 95.0 0.80 270 7.1 2.4 1■Q1222-3AC12-4■■■ 215 288 315 Δ 38.0 2739 93.9 95.0 95.3 0.81 335 7.1 2.4 1■Q1222-3AC32-4■■■ 240 322 315 Δ 38.0 3058 93.8 95.0 95.4 0.84 360 6.7 2.2 1■Q1222-3AC52-4■■■ 265 355 315 Δ 38.0 3376 93.9 95.1 95.5 0.84 400 6.6 2.2 1■Q1222-3AC72-4■■■ 320 429 355 Δ 37.9 4076 94.1 95.2 95.4 0.86 470 7.8 2.4 1■Q1222-3BC52-4■■■ 350 469 355 Δ 37.9 4458 94.2 95.3 95.5 0.87 510 8.0 2.2 1■Q1222-3BC72-4■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC72-4■■■ Prated 5/8 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency – low noise Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1212-3AB12-1... 1.Q1212-3AB32-1... 1.Q1212-3AB52-1... 1.Q1212-3AB72-1... 1.Q1212-3BB52-1... 1.Q1212-3BB72-1... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 320 400 452 560 560 710 1.Q1212-3AB12-2... 1.Q1212-3AB32-2... 1.Q1212-3AB52-2... 1.Q1212-3AB72-2... 1.Q1212-3BB52-2... 1.Q1212-3BB72-2... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 320 400 452 560 560 710 1.Q1212-3AC12-3... 1.Q1212-3AC32-3... 1.Q1212-3AC52-3... 1.Q1212-3AC72-3... 1.Q1212-3BC52-3... 1.Q1212-3BC72-3... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 320 400 400 452 560 560 1.Q1212-3AC12-4... 1.Q1212-3AC32-4... 1.Q1212-3AC52-4... 1.Q1212-3AC72-4... 1.Q1212-3BC52-4... 1.Q1212-3BC72-4... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 250 320 320 400 400 452 1.Q1222-3AB12-1... 1.Q1222-3AB32-1... 1.Q1222-3AB52-1... 1.Q1222-3AB72-1... 1.Q1222-3BB52-1... 1.Q1222-3BB72-1... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 370 477 590 590 725 725 1.Q1222-3AB12-2... 1.Q1222-3AB32-2... 1.Q1222-3AB52-2... 1.Q1222-3AB72-2... 1.Q1222-3BB52-2... 1.Q1222-3BB72-2... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 370 477 590 590 725 725 1.Q1222-3AC12-3... 1.Q1222-3AC32-3... 1.Q1222-3AC52-3... 1.Q1222-3AC72-3... 1.Q1222-3BC52-3... 1.Q1222-3BC72-3... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 370 477 477 590 590 725 1.Q1222-3AC12-4... 1.Q1222-3AC32-4... 1.Q1222-3AC52-4... 1.Q1222-3AC72-4... 1.Q1222-3BC52-4... 1.Q1222-3BC72-4... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GE33-1AA3 6SL3710-1GE33-8AA3 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 302 370 370 477 477 590 Siemens D 81.8 · 04/2014 5 5/9 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency – increased output ■ Selection and ordering data 5 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V 3000 rpm, 4-pole 265 355 315 Δ 100.7 844 94.5 95.0 94.6 0.89 350 6.1 2.1 1■Q1312-3AB12-1■■■ 1■Q1312-3AB32-1■■■ 345 463 315 Δ 100.6 1098 95.2 95.7 95.2 0.90 445 7.3 2.4 380 510 315 Δ 100.5 1210 95.4 95.8 95.4 0.90 490 7.6 2.5 1■Q1312-3AB52-1■■■ 405 543 315 Δ 100.7 1290 95.2 95.8 95.6 0.91 520 6.4 2.1 1■Q1312-3AB72-1■■■ 1■Q1312-3BB52-1■■■ 475 637 355 Δ 100.5 1512 95.7 96.2 95.8 0.89 620 6.8 2.4 500 671 355 Δ 100.6 1592 95.6 96.3 96.0 0.89 650 6.1 2.2 1■Q1312-3BB72-1■■■ 1500 rpm, 4-pole 245 329 315 Δ 50.5 1560 94.3 95.3 95.5 0.87 330 6.9 2.6 1■Q1312-3AB12-2■■■ 305 409 315 Δ 50.5 1942 94.7 95.6 95.9 0.89 400 7.5 2.7 1■Q1312-3AB32-2■■■ 360 483 315 Δ 50.5 2292 95.0 95.9 96.0 0.89 470 8.1 2.9 1■Q1312-3AB52-2■■■ 425 570 315 Δ 50.4 2706 95.3 96.1 96.2 0.88 560 9.1 2.7 1■Q1312-3AB72-2■■■ 460 617 355 Δ 50.4 2929 95.5 96.4 96.4 0.87 610 8.1 3.2 1■Q1312-3BB52-2■■■ 505 677 355 Δ 50.4 3218 95.7 96.5 96.5 0.87 670 8.9 3.1 1■Q1312-3BB72-2■■■ 1000 rpm, 6-pole 220 295 315 Δ 50.5 2102 94.3 95.3 95.5 0.81 315 7.4 2.3 1■Q1312-3AC12-3■■■ 270 362 315 Δ 50.5 2580 94.4 95.4 95.6 0.82 385 7.4 2.3 1■Q1312-3AC32-3■■■ 305 409 315 Δ 50.5 2915 94.4 95.5 95.7 0.84 420 7.1 2.2 1■Q1312-3AC52-3■■■ 1■Q1312-3AC72-3■■■ 340 456 315 Δ 50.5 3249 94.5 95.6 95.8 0.84 470 7.2 2.2 375 503 355 Δ 50.3 3583 94.9 95.7 95.7 0.85 510 9.3 2.8 1■Q1312-3BC52-3■■■ 410 550 355 Δ 50.3 3916 95.1 95.9 95.7 0.85 560 10.1 2.5 1■Q1312-3BC72-3■■■ 750 rpm, 6-pole 175 235 315 Δ 38.0 2230 93.0 94.3 94.6 0.79 260 7.0 2.4 1■Q1312-3AC12-4■■■ 215 288 315 Δ 38.0 2739 93.3 94.6 94.9 0.81 310 7.1 2.4 1■Q1312-3AC32-4■■■ 240 322 315 Δ 38.0 3058 93.2 94.6 95.0 0.84 335 6.6 2.2 1■Q1312-3AC52-4■■■ 275 369 315 Δ 38.0 3504 93.5 94.7 95.1 0.84 385 6.8 2.1 1■Q1312-3AC72-4■■■ 315 422 355 Δ 37.9 4012 94.0 95.0 95.2 0.85 435 8.3 2.5 1■Q1312-3BC52-4■■■ 335 449 355 Δ 37.9 4268 93.9 95.0 95.3 0.87 450 8.0 2.3 1■Q1312-3BC72-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V 3000 rpm, 4-pole 290 389 315 Δ 100.7 923 94.7 95.2 94.9 0.89 410 5.7 1.9 1■Q1322-3AB12-1■■■ 1■Q1322-3AB32-1■■■ 355 476 315 Δ 100.7 1130 95.1 95.6 95.4 0.90 495 6.0 2.0 395 530 315 Δ 100.7 1258 95.3 95.9 95.6 0.90 550 6.2 2.1 1■Q1322-3AB52-1■■■ 450 603 315 Δ 100.7 1433 95.5 96.1 95.8 0.91 620 6.5 2.1 1■Q1322-3AB72-1■■■ 485 650 355 Δ 100.6 1544 95.6 96.3 96.0 0.89 680 5.7 2.0 1■Q1322-3BB52-1■■■ 535 717 355 Δ 100.5 1703 95.8 96.4 96.1 0.89 750 6.7 2.4 1■Q1322-3BB72-1■■■ 1500 rpm, 4-pole 255 342 315 Δ 50.6 1624 94.4 95.4 95.7 0.88 365 6.6 2.4 1■Q1322-3AB12-2■■■ 350 469 315 Δ 50.5 2228 95.0 95.9 96.0 0.87 500 7.7 2.8 1■Q1322-3AB32-2■■■ 390 523 315 Δ 50.5 2483 95.0 96.0 96.1 0.89 550 7.7 2.8 1■Q1322-3AB52-2■■■ 435 583 315 Δ 50.5 2770 95.1 96.0 96.2 0.90 610 7.7 2.7 1■Q1322-3AB72-2■■■ 505 677 355 Δ 50.4 3215 95.7 96.5 96.5 0.87 720 8.1 3.1 1■Q1322-3BB52-2■■■ 530 711 355 Δ 50.5 3375 95.5 96.5 96.6 0.89 740 7.4 2.8 1■Q1322-3BB72-2■■■ 1000 rpm, 6-pole 230 308 315 Δ 50.6 2198 94.0 95.2 95.5 0.82 355 6.4 2.0 1■Q1322-3AC12-3■■■ 295 396 315 Δ 50.5 2819 94.5 95.6 95.8 0.82 455 7.0 2.2 1■Q1322-3AC32-3■■■ 335 449 315 Δ 50.5 3201 94.5 95.6 95.9 0.84 500 6.8 2.1 1■Q1322-3AC52-3■■■ 1■Q1322-3AC72-3■■■ 375 503 315 Δ 50.5 3583 94.8 95.7 95.9 0.84 560 7.1 2.1 405 543 355 Δ 50.4 3870 95.0 95.9 95.9 0.86 590 8.4 2.6 1■Q1322-3BC52-3■■■ 455 610 355 Δ 50.4 4347 95.2 96.0 95.9 0.86 660 9.1 2.3 1■Q1322-3BC72-3■■■ 750 rpm, 6-pole 190 255 315 Δ 38.1 2420 93.0 94.3 94.8 0.81 300 6.4 2.2 1■Q1322-3AC12-4■■■ 235 315 315 Δ 38.0 2994 93.4 94.7 95.1 0.82 365 6.5 2.2 1■Q1322-3AC32-4■■■ 265 355 315 Δ 38.1 3377 93.3 94.6 95.2 0.84 400 6.0 2.0 1■Q1322-3AC52-4■■■ 290 389 315 Δ 38.1 3695 93.4 94.7 95.3 0.85 435 6.0 2.0 1■Q1322-3AC72-4■■■ 335 449 355 Δ 37.9 4267 94.0 95.1 95.4 0.86 495 7.4 2.3 1■Q1322-3BC52-4■■■ 370 496 355 Δ 37.9 4713 94.1 95.2 95.4 0.87 540 7.6 2.1 1■Q1322-3BC72-4■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC72-4■■■ Prated 5/10 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency – increased output Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1312-3AB12-1... 1.Q1312-3AB32-1... 1.Q1312-3AB52-1... 1.Q1312-3AB72-1... 1.Q1312-3BB52-1... 1.Q1312-3BB72-1... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 400 452 560 560 710 710 1.Q1312-3AB12-2... 1.Q1312-3AB32-2... 1.Q1312-3AB52-2... 1.Q1312-3AB72-2... 1.Q1312-3BB52-2... 1.Q1312-3BB72-2... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 400 400 560 560 710 710 1.Q1312-3AC12-3... 1.Q1312-3AC32-3... 1.Q1312-3AC52-3... 1.Q1312-3AC72-3... 1.Q1312-3BC52-3... 1.Q1312-3BC72-3... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 320 400 452 560 560 560 1.Q1312-3AC12-4... 1.Q1312-3AC32-4... 1.Q1312-3AC52-4... 1.Q1312-3AC72-4... 1.Q1312-3BC52-4... 1.Q1312-3BC72-4... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG34-7AA3 320 320 400 400 452 452 1.Q1322-3AB12-1... 1.Q1322-3AB32-1... 1.Q1322-3AB52-1... 1.Q1322-3AB72-1... 1.Q1322-3BB52-1... 1.Q1322-3BB72-1... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 477 590 590 725 725 820 1.Q1322-3AB12-2... 1.Q1322-3AB32-2... 1.Q1322-3AB52-2... 1.Q1322-3AB72-2... 1.Q1322-3BB52-2... 1.Q1322-3BB72-2... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE33-8AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 370 590 590 725 725 820 1.Q1322-3AC12-3... 1.Q1322-3AC32-3... 1.Q1322-3AC52-3... 1.Q1322-3AC72-3... 1.Q1322-3BC52-3... 1.Q1322-3BC72-3... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 370 477 590 590 590 725 1.Q1322-3AC12-4... 1.Q1322-3AC32-4... 1.Q1322-3AC52-4... 1.Q1322-3AC72-4... 1.Q1322-3BC52-4... 1.Q1322-3BC72-4... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GE33-1AA3 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 302 370 477 477 590 590 Siemens D 81.8 · 04/2014 5 5/11 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 500 V, 50 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V 1500 rpm, 4-pole 5 180 241 315 Δ 50.4 1146 95.2 95.9 95.9 0.84 250 9.2 3.5 1■Q1213-3AB12-2■■■ 260 349 315 Δ 50.4 1655 95.1 96.0 96.1 0.88 340 8.7 3.1 1■Q1213-3AB32-2■■■ 335 449 315 Δ 50.5 2133 95.2 96.1 96.2 0.88 440 8.6 3.1 1■Q1213-3AB52-2■■■ 400 536 315 Δ 50.4 2547 95.5 96.3 96.4 0.87 530 9.6 2.9 1■Q1213-3AB72-2■■■ 420 563 355 Δ 50.4 2674 95.9 96.7 96.8 0.86 560 8.9 3.5 1■Q1213-3BB52-2■■■ 475 637 355 Δ 50.3 3026 96.0 96.8 96.8 0.85 640 9.3 3.3 1■Q1213-3BB72-2■■■ 1000 rpm, 6-pole 180 241 315 Δ 50.4 1719 94.9 95.8 95.8 0.79 265 8.7 2.9 1■Q1213-3AC12-3■■■ 245 329 315 Δ 50.4 2341 94.8 95.8 95.9 0.81 350 8.1 2.6 1■Q1213-3AC32-3■■■ 285 382 315 Δ 50.5 2723 94.7 95.8 96.0 0.84 395 7.5 2.4 1■Q1213-3AC52-3■■■ 315 422 315 Δ 50.5 3009 94.9 95.9 96.1 0.84 435 7.7 2.4 1■Q1213-3AC72-3■■■ 365 489 355 Δ 50.3 3487 95.3 96.2 96.2 0.84 500 9.5 2.8 1■Q1213-3BC52-3■■■ 405 543 355 Δ 50.3 3868 95.5 96.3 96.3 0.83 560 10.0 2.6 1■Q1213-3BC72-3■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V 1500 rpm, 4-pole 205 275 315 Δ 50.5 1305 95.1 96.0 96.0 0.86 300 8.0 3.0 1■Q1223-3AB12-2■■■ 330 443 315 Δ 50.5 2101 95.2 96.1 96.2 0.87 475 8.1 3.0 1■Q1223-3AB32-2■■■ 365 489 315 Δ 50.5 2324 95.3 96.2 96.4 0.88 520 8.2 3.0 1■Q1223-3AB52-2■■■ 415 557 315 Δ 50.5 2642 95.3 96.2 96.5 0.90 580 8.0 2.8 1■Q1223-3AB72-2■■■ 475 637 355 Δ 50.4 3024 96.0 96.8 96.9 0.86 690 8.5 3.3 1■Q1223-3BB52-2■■■ 495 664 355 Δ 50.4 3152 95.8 96.8 96.9 0.88 700 7.8 3.0 1■Q1223-3BB72-2■■■ 1000 rpm, 6-pole 190 255 315 Δ 50.5 1816 94.8 95.8 95.9 0.81 295 7.7 2.5 1■Q1223-3AC12-3■■■ 275 369 315 Δ 50.5 2627 94.8 95.8 96.0 0.82 420 7.6 2.4 1■Q1223-3AC32-3■■■ 310 416 315 Δ 50.5 2962 94.9 95.9 96.1 0.83 470 7.2 2.3 1■Q1223-3AC52-3■■■ 350 469 315 Δ 50.5 3344 95.1 96.0 96.2 0.83 530 7.5 2.2 1■Q1223-3AC72-3■■■ 395 530 355 Δ 50.4 3773 95.3 96.2 96.3 0.85 580 8.5 2.6 1■Q1223-3BC52-3■■■ 445 597 355 Δ 50.4 4251 95.5 96.4 96.4 0.85 650 9.2 2.3 1■Q1223-3BC72-3■■■ For versions, see Article No. supplements and special versions 5/12 Siemens D 81.8 · 04/2014 1■M1223-3AC72-3■■■ © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 500 V, 50 Hz Premium Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1213-3AB12-2... 1310 1360 3.5 79 94.5 3000 1XB7 730 6SL3710-7LG32-6AA3 250 1.Q1213-3AB32-2... 1490 1540 4.4 79 94.5 3000 1XB7 730 6SL3710-7LG34-1AA3 400 1.Q1213-3AB52-2... 1670 1720 5 79 94.5 3000 1XB7 731 6SL3710-7LG34-7AA3 452 1.Q1213-3AB72-2... 1830 1880 5.8 79 94.5 3000 1XB7 731 6SL3710-7LG35-8AA3 560 1.Q1213-3BB52-2... 2300 2350 8.3 79 95 2600 1XB7 731 6SL3710-7LG35-8AA3 560 1.Q1213-3BB72-2... 2420 2480 8.9 79 95 2600 1XB7 740 6SL3710-7LG37-4AA3 710 1.Q1213-3AC12-3... 1340 1390 5.9 79 94.5 2600 1XB7 730 6SL3710-7LG33-3AA3 320 1.Q1213-3AC32-3... 1520 1570 7.2 79 94.5 2600 1XB7 730 6SL3710-7LG34-1AA3 400 1.Q1213-3AC52-3... 1700 1750 8.3 79 94.5 2600 1XB7 731 6SL3710-7LG34-1AA3 400 1.Q1213-3AC72-3... 1810 1860 9.1 79 94.5 2600 1XB7 731 6SL3710-7LG34-7AA3 452 1.Q1213-3BC52-3... 2290 2350 14.5 79 95 2500 1XB7 731 6SL3710-7LG35-8AA3 560 1.Q1213-3BC72-3... 2440 2490 16 79 95 2500 1XB7 731 6SL3710-7LG35-8AA3 560 1.Q1223-3AB12-2... 1310 1360 3.5 79 94.5 3000 1XB7 730 6SL3710-1GE33-1AA3 302 1.Q1223-3AB32-2... 1490 1540 4.4 79 94.5 3000 1XB7 731 6SL3710-1GE35-0AA3 477 1.Q1223-3AB52-2... 1670 1720 5 79 94.5 3000 1XB7 731 6SL3710-1GE36-1AA3 590 1.Q1223-3AB72-2... 1830 1880 5.8 79 94.5 3000 1XB7 731 6SL3710-1GE36-1AA3 590 1.Q1223-3BB52-2... 2300 2350 8.3 79 95 2600 1XB7 740 6SL3710-1GE37-5AA3 725 1.Q1223-3BB72-2... 2420 2480 8.9 79 95 2600 1XB7 740 6SL3710-1GE37-5AA3 725 1.Q1223-3AC12-3... 1340 1390 5.9 79 94.5 2600 1XB7 730 6SL3710-1GE33-1AA3 302 1.Q1223-3AC32-3... 1520 1570 7.2 79 94.5 2600 1XB7 731 6SL3710-1GE35-0AA3 477 1.Q1223-3AC52-3... 1700 1750 8.3 79 94.5 2600 1XB7 731 6SL3710-1GE35-0AA3 477 1.Q1223-3AC72-3... 1810 1860 9.1 79 94.5 2600 1XB7 731 6SL3710-1GE36-1AA3 590 1.Q1223-3BC52-3... 2290 2350 14.5 79 95 2500 1XB7 731 6SL3710-1GE36-1AA3 590 1.Q1223-3BC72-3... 2440 2490 16 79 95 2500 1XB7 740 6SL3710-1GE37-5AA3 725 Siemens D 81.8 · 04/2014 5 5/13 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency – low noise ■ Selection and ordering data 5 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V 3000 rpm, 4-pole 240 322 315 Δ 100.6 764 94.6 95.0 94.5 0.89 225 6.6 2.2 1■Q1212-3AB13-1■■■ 1■Q1212-3AB33-1■■■ 310 416 315 Δ 100.5 987 95.2 95.6 95.1 0.89 290 7.5 2.6 350 469 315 Δ 100.5 1114 95.4 95.8 95.3 0.90 320 8.7 2.9 1■Q1212-3AB53-1■■■ 400 536 315 Δ 100.5 1273 95.6 96.0 95.6 0.90 365 8.2 2.7 1■Q1212-3AB73-1■■■ 1■Q1212-3BB53-1■■■ 450 603 355 Δ 100.5 1433 95.6 96.2 95.8 0.89 415 7.0 2.5 470 630 355 Δ 100.5 1497 95.6 96.2 95.9 0.89 435 6.2 2.2 1■Q1212-3BB73-1■■■ 1500 rpm, 4-pole 215 288 315 Δ 50.5 1369 94.8 95.6 95.6 0.86 205 8.3 3.0 1■Q1212-3AB13-2■■■ 290 389 315 Δ 50.4 1846 95.1 95.9 95.9 0.86 280 8.8 3.2 1■Q1212-3AB33-2■■■ 335 449 315 Δ 50.4 2133 95.3 95.9 96.1 0.88 315 9.2 3.3 1■Q1212-3AB53-2■■■ 385 516 315 Δ 50.4 2451 95.4 96.2 96.2 0.88 360 9.5 3.0 1■Q1212-3AB73-2■■■ 410 550 355 Δ 50.4 2610 95.7 96.5 96.5 0.87 385 8.7 3.4 1■Q1212-3BB53-2■■■ 440 590 355 Δ 50.4 2801 95.7 96.5 96.5 0.87 415 8.9 3.4 1■Q1212-3BB73-2■■■ 1000 rpm, 6-pole 195 261 315 Y 50.4 1863 94.5 95.4 95.5 0.80 200 8.1 2.6 1■Q1212-3AC13-3■■■ 245 329 315 Y 50.4 2341 94.7 95.6 95.7 0.82 245 8.1 2.5 1■Q1212-3AC33-3■■■ 280 375 315 Y 50.5 2675 94.8 95.7 95.9 0.84 280 7.8 2.5 1■Q1212-3AC53-3■■■ 1■Q1212-3AC73-3■■■ 315 422 315 Δ 50.4 3009 95.0 95.7 96.0 0.84 310 8.0 2.5 345 463 355 Δ 50.3 3295 95.0 95.7 95.7 0.85 335 10.0 3.0 1■Q1212-3BC53-3■■■ 385 516 355 Δ 50.3 3677 95.2 95.9 95.7 0.84 380 10.6 2.7 1■Q1212-3BC73-3■■■ 750 rpm, 6-pole 155 208 315 Y 37.9 1975 93.5 94.6 94.8 0.79 164 7.7 2.6 1■Q1212-3AC13-4■■■ 200 268 315 Y 38.0 2548 93.8 94.9 95.2 0.81 205 7.5 2.5 1■Q1212-3AC33-4■■■ 225 302 315 Δ 38.0 2867 93.8 95.0 95.3 0.83 225 7.3 2.4 1■Q1212-3AC53-4■■■ 255 342 315 Δ 38.0 3249 93.9 95.1 95.4 0.84 250 7.1 2.3 1■Q1212-3AC73-4■■■ 295 396 355 Y 37.9 3758 94.1 95.1 95.2 0.85 290 8.7 2.6 1■Q1212-3BC53-4■■■ 330 443 355 Δ 37.8 4204 94.3 95.3 95.3 0.85 320 9.0 2.4 1■Q1212-3BC73-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V 3000 rpm, 4-pole 240 322 315 Δ 100.6 764 94.7 95.0 94.5 0.88 250 6.9 2.4 1■Q1222-3AB13-1■■■ 1■Q1222-3AB33-1■■■ 300 402 315 Δ 100.5 955 95.1 95.5 95.0 0.90 305 7.6 2.5 340 456 315 Δ 100.5 1082 95.4 95.8 95.3 0.90 345 8.8 2.9 1■Q1222-3AB53-1■■■ 390 523 315 Δ 100.5 1242 95.6 96.0 95.6 0.90 395 8.5 2.8 1■Q1222-3AB73-1■■■ 420 563 355 Δ 100.4 1337 95.6 96.1 95.6 0.89 430 7.5 2.7 1■Q1222-3BB53-1■■■ 440 590 355 Δ 100.5 1401 95.6 96.2 95.8 0.89 450 6.7 2.4 1■Q1222-3BB73-1■■■ 1500 rpm, 4-pole 230 308 315 Δ 50.5 1464 94.7 95.6 95.7 0.86 245 7.7 2.9 1■Q1222-3AB13-2■■■ 290 389 315 Δ 50.5 1846 95.0 95.9 96.0 0.88 300 8.3 3.0 1■Q1222-3AB33-2■■■ 325 436 315 Δ 50.4 2069 95.2 95.9 96.1 0.88 335 8.8 3.2 1■Q1222-3AB53-2■■■ 385 516 315 Δ 50.4 2451 95.4 96.2 96.3 0.89 395 9.3 3.0 1■Q1222-3AB73-2■■■ 400 536 355 Δ 50.3 2548 95.8 96.5 96.4 0.84 430 9.9 3.9 1■Q1222-3BB53-2■■■ 430 577 355 Δ 50.4 2738 95.7 96.5 96.5 0.87 450 8.8 3.4 1■Q1222-3BB73-2■■■ 1000 rpm, 6-pole 195 261 315 Y 50.5 1863 94.5 95.4 95.5 0.80 225 7.8 2.5 1■Q1222-3AC13-3■■■ 245 329 315 Δ 50.4 2341 94.7 95.6 95.7 0.82 275 8.1 2.6 1■Q1222-3AC33-3■■■ 285 382 315 Δ 50.5 2723 94.9 95.7 95.9 0.84 310 7.9 2.5 1■Q1222-3AC53-3■■■ 1■Q1222-3AC73-3■■■ 310 416 315 Δ 50.4 2961 95.0 95.7 95.9 0.83 340 8.5 2.5 345 463 355 Δ 50.3 3295 95.0 95.7 95.7 0.85 370 9.7 3.0 1■Q1222-3BC53-3■■■ 365 489 355 Δ 50.3 3486 95.3 95.7 95.6 0.83 400 11.2 2.8 1■Q1222-3BC73-3■■■ 750 rpm, 6-pole 155 208 315 Y 38.0 1975 93.3 94.5 94.8 0.80 180 7.3 2.5 1■Q1222-3AC13-4■■■ 205 275 315 Δ 37.9 2611 93.9 95.0 95.1 0.80 235 7.8 2.6 1■Q1222-3AC33-4■■■ 225 302 315 Δ 38.0 2866 93.9 95.0 95.3 0.83 250 7.5 2.5 1■Q1222-3AC53-4■■■ 245 329 315 Δ 38.0 3121 93.9 95.0 95.4 0.84 270 7.2 2.4 1■Q1222-3AC73-4■■■ 295 396 355 Δ 37.9 3757 94.1 95.2 95.2 0.85 320 8.9 2.6 1■Q1222-3BC53-4■■■ 320 429 355 Δ 37.9 4076 94.2 95.2 95.3 0.86 340 8.8 2.4 1■Q1222-3BC73-4■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC73-4■■■ Prated 5/14 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency – low noise Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1212-3AB13-1... 1.Q1212-3AB33-1... 1.Q1212-3AB53-1... 1.Q1212-3AB73-1... 1.Q1212-3BB53-1... 1.Q1212-3BB73-1... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG34-7AA3 250 320 320 400 452 452 1.Q1212-3AB13-2... 1.Q1212-3AB33-2... 1.Q1212-3AB53-2... 1.Q1212-3AB73-2... 1.Q1212-3BB53-2... 1.Q1212-3BB73-2... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG32-2AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 208 320 320 400 400 452 1.Q1212-3AC13-3... 1.Q1212-3AC33-3... 1.Q1212-3AC53-3... 1.Q1212-3AC73-3... 1.Q1212-3BC53-3... 1.Q1212-3BC73-3... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 6SL3710-7LG32-2AA3 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 208 250 320 320 400 400 1.Q1212-3AC13-4... 1.Q1212-3AC33-4... 1.Q1212-3AC53-4... 1.Q1212-3AC73-4... 1.Q1212-3BC53-4... 1.Q1212-3BC73-4... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 6SL3710-7LG31-8AA3 6SL3710-7LG32-2AA3 6SL3710-7LG32-6AA3 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 170 208 250 250 320 320 1.Q1222-3AB13-1... 1.Q1222-3AB33-1... 1.Q1222-3AB53-1... 1.Q1222-3AB73-1... 1.Q1222-3BB53-1... 1.Q1222-3BB73-1... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GH32-6AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH34-7AA3 250 320 400 400 452 452 1.Q1222-3AB13-2... 1.Q1222-3AB33-2... 1.Q1222-3AB53-2... 1.Q1222-3AB73-2... 1.Q1222-3BB53-2... 1.Q1222-3BB73-2... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GH32-6AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH34-7AA3 250 320 400 400 452 452 1.Q1222-3AC13-3... 1.Q1222-3AC33-3... 1.Q1222-3AC53-3... 1.Q1222-3AC73-3... 1.Q1222-3BC53-3... 1.Q1222-3BC73-3... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-1GH32-6AA3 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 250 320 320 400 400 400 1.Q1222-3AC13-4... 1.Q1222-3AC33-4... 1.Q1222-3AC53-4... 1.Q1222-3AC73-4... 1.Q1222-3BC53-4... 1.Q1222-3BC73-4... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 6SL3710-1GH32-2AA3 6SL3710-1GH32-6AA3 6SL3710-1GH32-6AA3 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 208 250 250 320 320 400 Siemens D 81.8 · 04/2014 5 5/15 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency – increased output ■ Selection and ordering data 5 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V 3000 rpm, 4-pole 265 355 315 Δ 100.7 844 94.5 95.0 94.6 0.89 250 5.9 2.0 1■Q1312-3AB13-1■■■ 1■Q1312-3AB33-1■■■ 345 463 315 Δ 100.6 1098 95.1 95.6 95.2 0.90 315 6.9 2.3 395 530 315 Δ 100.5 1258 95.4 95.9 95.5 0.90 360 7.7 2.6 1■Q1312-3AB53-1■■■ 440 590 315 Δ 100.6 1401 95.5 96.0 95.7 0.91 400 7.5 2.5 1■Q1312-3AB73-1■■■ 1■Q1312-3BB53-1■■■ 485 650 355 Δ 100.5 1544 95.6 96.2 95.9 0.89 450 6.4 2.3 510 684 355 Δ 100.6 1624 95.6 96.2 96.0 0.89 470 5.8 2.1 1■Q1312-3BB73-1■■■ 1500 rpm, 4-pole 245 329 315 Δ 50.5 1560 94.4 95.3 95.5 0.87 235 7.2 2.7 1■Q1312-3AB13-2■■■ 315 422 315 Δ 50.5 2006 94.8 95.7 95.9 0.87 300 8.2 3.0 1■Q1312-3AB33-2■■■ 365 489 315 Δ 50.5 2324 95.1 95.9 96.1 0.88 340 8.5 3.0 1■Q1312-3AB53-2■■■ 415 557 315 Δ 50.5 2642 95.2 96.1 96.2 0.89 385 8.9 2.8 1■Q1312-3AB73-2■■■ 460 617 355 Δ 50.4 2929 95.5 96.4 96.5 0.88 430 7.7 3.0 1■Q1312-3BB53-2■■■ 485 650 355 Δ 50.4 3088 95.6 96.5 96.5 0.88 450 8.2 3.1 1■Q1312-3BB73-2■■■ 1000 rpm, 6-pole 215 288 315 Y 50.5 2055 94.1 95.1 95.3 0.81 220 7.3 2.3 1■Q1312-3AC13-3■■■ 270 362 315 Y 50.5 2580 94.3 95.4 95.6 0.83 270 7.3 2.3 1■Q1312-3AC33-3■■■ 310 416 315 Y 50.5 2962 94.4 95.5 95.7 0.84 305 7.1 2.2 1■Q1312-3AC53-3■■■ 1■Q1312-3AC73-3■■■ 350 469 315 Δ 50.5 3344 94.6 95.6 95.8 0.84 345 7.2 2.2 370 496 355 Δ 50.3 3535 94.9 95.7 95.7 0.85 360 9.3 2.8 1■Q1312-3BC53-3■■■ 410 550 355 Δ 50.3 3916 95.1 95.9 95.7 0.85 400 10.1 2.5 1■Q1312-3BC73-3■■■ 750 rpm, 6-pole 160 215 315 Y 38.0 2039 93.2 94.4 94.6 0.79 170 7.4 2.5 1■Q1312-3AC13-4■■■ 220 295 315 Y 38.0 2803 93.3 94.6 95.0 0.82 225 6.9 2.3 1■Q1312-3AC33-4■■■ 245 329 315 Δ 38.0 3122 93.3 94.6 95.1 0.84 245 6.7 2.2 1■Q1312-3AC53-4■■■ 275 369 315 Δ 38.0 3504 93.5 94.8 95.2 0.85 270 6.6 2.1 1■Q1312-3AC73-4■■■ 315 422 355 Y 37.9 4013 93.9 95.0 95.2 0.86 305 8.3 2.5 1■Q1312-3BC53-4■■■ 350 469 355 Δ 37.9 4458 94.1 95.2 95.3 0.86 340 8.5 2.2 1■Q1312-3BC73-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V 3000 rpm, 4-pole 265 355 315 Δ 100.6 844 94.6 95.1 94.6 0.89 275 6.3 2.1 1■Q1322-3AB13-1■■■ 1■Q1322-3AB33-1■■■ 330 443 315 Δ 100.6 1051 95.1 95.6 95.2 0.90 335 6.9 2.3 380 510 315 Δ 100.5 1210 95.4 95.8 95.4 0.90 385 7.9 2.6 1■Q1322-3AB53-1■■■ 435 583 315 Δ 100.6 1385 95.5 96.0 95.7 0.91 435 7.7 2.5 1■Q1322-3AB73-1■■■ 465 624 355 Δ 100.5 1481 95.6 96.2 95.8 0.89 475 6.8 2.4 1■Q1322-3BB53-1■■■ 485 650 355 Δ 100.6 1544 95.6 96.2 96.0 0.89 495 6.1 2.2 1■Q1322-3BB73-1■■■ 1500 rpm, 4-pole 250 335 315 Δ 50.5 1592 94.4 95.4 95.6 0.87 265 7.1 2.6 1■Q1322-3AB13-2■■■ 310 416 315 Δ 50.5 1974 94.8 95.7 95.9 0.88 320 7.8 2.8 1■Q1322-3AB33-2■■■ 350 469 315 Δ 50.5 2228 94.9 95.9 96.0 0.89 360 8.2 2.9 1■Q1322-3AB53-2■■■ 415 557 315 Δ 50.5 2642 95.2 96.1 96.2 0.89 425 8.6 2.8 1■Q1322-3AB73-2■■■ 455 610 355 Δ 50.4 2897 95.7 96.5 96.4 0.86 480 8.8 3.4 1■Q1322-3BB53-2■■■ 480 644 355 Δ 50.4 3056 95.6 96.5 96.5 0.88 495 8.0 3.1 1■Q1322-3BB73-2■■■ 1000 rpm, 6-pole 215 288 315 Y 50.5 2055 94.1 95.1 95.3 0.81 245 7.2 2.3 1■Q1322-3AC13-3■■■ 270 362 315 Δ 50.5 2580 94.4 95.4 95.6 0.83 300 7.4 2.3 1■Q1322-3AC33-3■■■ 315 422 315 Δ 50.5 3010 94.5 95.5 95.8 0.84 345 7.1 2.2 1■Q1322-3AC53-3■■■ 1■Q1322-3AC73-3■■■ 345 463 315 Δ 50.5 3296 94.7 95.7 95.8 0.83 380 7.6 2.2 370 496 355 Δ 50.4 3535 94.9 95.7 95.7 0.86 395 9.1 2.8 1■Q1322-3BC53-3■■■ 405 543 355 Δ 50.3 3868 95.1 95.9 95.7 0.84 440 10.1 2.6 1■Q1322-3BC73-3■■■ 750 rpm, 6-pole 170 228 315 Y 38.0 2166 92.8 94.1 94.6 0.81 196 6.7 2.3 1■Q1322-3AC13-4■■■ 220 295 315 Δ 38.0 2803 93.5 94.7 95.0 0.81 250 7.3 2.5 1■Q1322-3AC33-4■■■ 250 335 315 Δ 38.0 3185 93.4 94.7 95.1 0.84 275 6.8 2.2 1■Q1322-3AC53-4■■■ 270 362 315 Δ 38.0 3441 93.3 94.7 95.1 0.85 295 6.6 2.1 1■Q1322-3AC73-4■■■ 315 422 355 Δ 37.9 4012 94.0 95.1 95.2 0.86 335 8.5 2.5 1■Q1322-3BC53-4■■■ 340 456 355 Δ 37.9 4331 94.0 95.1 95.3 0.86 365 8.2 2.3 1■Q1322-3BC73-4■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC73-4■■■ Prated 5/16 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency – increased output Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1312-3AB13-1... 1.Q1312-3AB33-1... 1.Q1312-3AB53-1... 1.Q1312-3AB73-1... 1.Q1312-3BB53-1... 1.Q1312-3BB73-1... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 250 320 400 400 452 560 1.Q1312-3AB13-2... 1.Q1312-3AB33-2... 1.Q1312-3AB53-2... 1.Q1312-3AB73-2... 1.Q1312-3BB53-2... 1.Q1312-3BB73-2... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG34-7AA3 250 320 400 400 452 452 1.Q1312-3AC13-3... 1.Q1312-3AC33-3... 1.Q1312-3AC53-3... 1.Q1312-3AC73-3... 1.Q1312-3BC53-3... 1.Q1312-3BC73-3... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 250 320 320 400 400 400 1.Q1312-3AC13-4... 1.Q1312-3AC33-4... 1.Q1312-3AC53-4... 1.Q1312-3AC73-4... 1.Q1312-3BC53-4... 1.Q1312-3BC73-4... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 6SL3710-7LG31-8AA3 6SL3710-7LG32-6AA3 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 170 250 250 320 320 400 1.Q1322-3AB13-1... 1.Q1322-3AB33-1... 1.Q1322-3AB53-1... 1.Q1322-3AB73-1... 1.Q1322-3BB53-1... 1.Q1322-3BB73-1... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH35-8AA3 320 400 400 452 560 560 1.Q1322-3AB13-2... 1.Q1322-3AB33-2... 1.Q1322-3AB53-2... 1.Q1322-3AB73-2... 1.Q1322-3BB53-2... 1.Q1322-3BB73-2... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH35-8AA3 320 320 400 452 560 560 1.Q1322-3AC13-3... 1.Q1322-3AC33-3... 1.Q1322-3AC53-3... 1.Q1322-3AC73-3... 1.Q1322-3BC53-3... 1.Q1322-3BC73-3... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GH32-6AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 250 320 400 400 400 452 1.Q1322-3AC13-4... 1.Q1322-3AC33-4... 1.Q1322-3AC53-4... 1.Q1322-3AC73-4... 1.Q1322-3BC53-4... 1.Q1322-3BC73-4... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 6SL3710-1GH32-2AA3 6SL3710-1GH32-6AA3 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 208 250 320 320 400 400 Siemens D 81.8 · 04/2014 5 5/17 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 690 V, 50 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V 1500 rpm, 4-pole 5 185 248 315 Δ 50.4 1178 95.2 95.9 95.8 0.83 184 9.3 3.6 1■Q1213-3AB13-2■■■ 300 402 315 Δ 50.4 1910 95.1 96.0 96.1 0.87 285 8.6 3.1 1■Q1213-3AB33-2■■■ 340 456 315 Δ 50.4 2165 95.3 96.2 96.3 0.87 320 8.9 3.2 1■Q1213-3AB53-2■■■ 395 530 315 Δ 50.4 2515 95.4 96.3 96.4 0.88 370 9.2 2.9 1■Q1213-3AB73-2■■■ 425 570 355 Δ 50.4 2706 95.8 96.7 96.8 0.87 400 8.3 3.2 1■Q1213-3BB53-2■■■ 465 624 355 Δ 50.4 2961 95.8 96.8 96.9 0.87 435 8.5 3.3 1■Q1213-3BB73-2■■■ 1000 rpm, 6-pole 175 235 315 Y 50.4 1672 94.9 95.7 95.7 0.79 184 8.8 2.9 1■Q1213-3AC13-3■■■ 240 322 315 Y 50.4 2293 94.8 95.8 95.9 0.82 240 8.2 2.6 1■Q1213-3AC33-3■■■ 285 382 315 Y 50.5 2723 94.8 95.8 96.0 0.83 285 7.6 2.4 1■Q1213-3AC53-3■■■ 325 436 315 Δ 50.5 3105 94.9 95.9 96.1 0.84 320 7.7 2.4 1■Q1213-3AC73-3■■■ 365 489 355 Δ 50.3 3487 95.3 96.2 96.2 0.84 355 9.4 2.8 1■Q1213-3BC53-3■■■ 405 543 355 Δ 50.3 3868 95.5 96.3 96.3 0.83 400 10.1 2.6 1■Q1213-3BC73-3■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V 1500 rpm, 4-pole 185 248 315 Δ 50.4 1178 95.2 95.9 95.8 0.84 200 9.3 3.5 1■Q1223-3AB13-2■■■ 285 382 315 Δ 50.5 1815 95.1 96.0 96.1 0.88 295 8.4 3.0 1■Q1223-3AB33-2■■■ 330 443 315 Δ 50.5 2101 95.2 96.1 96.2 0.88 340 8.7 3.1 1■Q1223-3AB53-2■■■ 390 523 315 Δ 50.4 2483 95.4 96.3 96.4 0.89 400 9.0 3.0 1■Q1223-3AB73-2■■■ 420 563 355 Δ 50.3 2676 96.0 96.8 96.8 0.84 450 9.4 3.7 1■Q1223-3BB53-2■■■ 450 603 355 Δ 50.4 2865 95.9 96.8 96.9 0.87 465 8.5 3.3 1■Q1223-3BB73-2■■■ 1000 rpm, 6-pole 175 235 315 Y 50.4 1672 94.9 95.7 95.7 0.79 200 8.8 2.8 1■Q1223-3AC13-3■■■ 240 322 315 Δ 50.4 2293 94.8 95.8 95.9 0.81 270 8.2 2.6 1■Q1223-3AC33-3■■■ 290 389 315 Δ 50.5 2771 94.8 95.9 96.1 0.84 315 7.7 2.4 1■Q1223-3AC53-3■■■ 320 429 315 Δ 50.4 3057 95.0 95.9 96.1 0.83 350 8.2 2.4 1■Q1223-3AC73-3■■■ 360 483 355 Δ 50.3 3439 95.3 96.2 96.2 0.85 385 9.3 2.9 1■Q1223-3BC53-3■■■ 395 530 355 Δ 50.3 3772 95.5 96.3 96.3 0.83 430 10.4 2.6 1■Q1223-3BC73-3■■■ For versions, see Article No. supplements and special versions 5/18 Siemens D 81.8 · 04/2014 1■M1223-3AC73-3■■■ © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 690 V, 50 Hz Premium Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1213-3AB13-2... 1310 1360 3.5 79 94.5 3000 1XB7 730 6SL3710-7LG32-2AA3 208 1.Q1213-3AB33-2... 1490 1540 4.4 79 94.5 3000 1XB7 730 6SL3710-7LG33-3AA3 320 1.Q1213-3AB53-2... 1670 1720 5 79 94.5 3000 1XB7 730 6SL3710-7LG33-3AA3 320 1.Q1213-3AB73-2... 1830 1880 5.8 79 94.5 3000 1XB7 731 6SL3710-7LG34-1AA3 400 1.Q1213-3BB53-2... 2300 2350 8.3 79 95 2600 1XB7 731 6SL3710-7LG34-1AA3 400 1.Q1213-3BB73-2... 2420 2480 8.9 79 95 2600 1XB7 731 6SL3710-7LG34-7AA3 452 1.Q1213-3AC13-3... 1340 1390 5.9 79 94.5 2600 1XB7 730 6SL3710-7LG32-2AA3 208 1.Q1213-3AC33-3... 1520 1570 7.2 79 94.5 2600 1XB7 730 6SL3710-7LG32-6AA3 250 1.Q1213-3AC53-3... 1700 1750 8.3 79 94.5 2600 1XB7 730 6SL3710-7LG33-3AA3 320 1.Q1213-3AC73-3... 1810 1860 9.1 79 94.5 2600 1XB7 730 6SL3710-7LG33-3AA3 320 1.Q1213-3BC53-3... 2290 2350 14.5 79 95 2500 1XB7 731 6SL3710-7LG34-1AA3 400 1.Q1213-3BC73-3... 2440 2490 16 79 95 2500 1XB7 731 6SL3710-7LG34-1AA3 400 1.Q1223-3AB13-2... 1310 1360 3.5 79 94.5 3000 1XB7 730 6SL3710-1GH32-2AA3 208 1.Q1223-3AB33-2... 1490 1540 4.4 79 94.5 3000 1XB7 730 6SL3710-1GH33-3AA3 320 1.Q1223-3AB53-2... 1670 1720 5 79 94.5 3000 1XB7 730 6SL3710-1GH34-1AA3 400 1.Q1223-3AB73-2... 1830 1880 5.8 79 94.5 3000 1XB7 731 6SL3710-1GH34-1AA3 400 1.Q1223-3BB53-2... 2300 2350 8.3 79 95 2600 1XB7 731 6SL3710-1GH34-7AA3 452 1.Q1223-3BB73-2... 2420 2480 8.9 79 95 2600 1XB7 731 6SL3710-1GH35-8AA3 560 1.Q1223-3AC13-3... 1340 1390 5.9 79 94.5 2600 1XB7 730 6SL3710-1GH32-2AA3 208 1.Q1223-3AC33-3... 1520 1570 7.2 79 94.5 2600 1XB7 730 6SL3710-1GH33-3AA3 320 1.Q1223-3AC53-3... 1700 1750 8.3 79 94.5 2600 1XB7 730 6SL3710-1GH33-3AA3 320 1.Q1223-3AC73-3... 1810 1860 9.1 79 94.5 2600 1XB7 730 6SL3710-1GH34-1AA3 400 1.Q1223-3BC53-3... 2290 2350 14.5 79 95 2500 1XB7 731 6SL3710-1GH34-1AA3 400 1.Q1223-3BC73-3... 2440 2490 16 79 95 2500 1XB7 731 6SL3710-1GH34-7AA3 452 Siemens D 81.8 · 04/2014 5 5/19 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency – low noise ■ Selection and ordering data 5 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V 3600 rpm, 4-pole 285 382 315 Δ 120.6 756 94.5 94.7 93.8 0.88 410 7.2 2.4 1■Q1212-3AB15-5■■■ 345 463 315 Δ 120.5 915 95.0 95.2 94.3 0.89 490 8.6 2.9 1■Q1212-3AB35-5■■■ 375 503 315 Δ 120.6 995 95.1 95.4 94.7 0.90 530 7.1 2.4 1■Q1212-3AB55-5■■■ 430 577 315 Δ 120.6 1141 95.4 95.7 95.0 0.91 590 7.8 2.5 1■Q1212-3AB75-5■■■ 3000 rpm, 4-pole 450 603 355 Δ 100.6 1433 95.6 96.2 95.9 0.89 630 6.1 2.2 1■Q1212-3BB55-1■■■ 1■Q1212-3BB75-1■■■ 495 664 355 Δ 100.5 1576 95.8 96.4 96.0 0.89 690 7.2 2.6 1800 rpm, 4-pole 285 382 315 Δ 60.5 1512 95.2 96.0 95.9 0.86 415 7.8 2.8 1■Q1212-3AB15-6■■■ 1■Q1212-3AB35-6■■■ 350 469 315 Δ 60.5 1857 95.5 96.1 96.2 0.88 495 8.0 2.8 1■Q1212-3AB55-6■■■ 390 523 315 Δ 60.5 2069 95.6 96.4 96.4 0.89 550 8.1 2.8 480 644 315 Δ 60.4 2549 96.0 96.7 96.6 0.88 680 9.9 2.9 1■Q1212-3AB75-6■■■ 485 650 355 Δ 60.4 2575 96.1 96.8 96.6 0.86 700 9.3 3.6 1■Q1212-3BB55-6■■■ 1■Q1212-3BB75-6■■■ 510 684 355 Δ 60.4 2706 96.0 96.8 96.7 0.88 720 8.4 3.2 1200 rpm, 6-pole 240 322 315 Δ 60.5 1911 95.0 95.7 95.9 0.82 365 7.5 2.3 1■Q1212-3AC15-7■■■ 295 396 315 Δ 60.5 2349 95.2 95.7 96.1 0.84 445 7.5 2.3 1■Q1212-3AC35-7■■■ 355 476 315 Δ 60.5 2826 95.5 95.7 96.3 0.84 530 8.1 2.5 1■Q1212-3AC55-7■■■ 1■Q1212-3AC75-7■■■ 380 510 315 Δ 60.5 3026 95.5 96.3 96.3 0.84 570 7.8 2.4 400 536 355 Δ 60.3 3184 95.6 96.3 95.9 0.84 590 11.0 3.1 1■Q1212-3BC55-7■■■ 1■Q1212-3BC75-7■■■ 445 597 355 Δ 60.3 3541 95.7 96.3 96.0 0.85 650 10.6 2.8 900 rpm, 6-pole 205 275 315 Δ 45.5 2177 94.3 95.4 95.5 0.80 325 7.2 2.4 1■Q1212-3AC15-8■■■ 1■Q1212-3AC35-8■■■ 250 335 315 Δ 45.4 2653 94.8 95.6 95.7 0.79 400 8.0 2.7 280 375 315 Δ 45.5 2972 94.6 95.6 95.8 0.84 420 7.2 2.3 1■Q1212-3AC55-8■■■ 1■Q1212-3AC75-8■■■ 310 416 315 Δ 45.5 3291 94.7 95.7 95.9 0.84 465 7.4 2.2 355 476 355 Δ 45.4 3768 94.7 95.7 95.7 0.86 520 8.2 2.6 1■Q1212-3BC55-8■■■ 395 530 355 Δ 45.4 4193 94.9 95.8 95.8 0.86 580 8.6 2.4 1■Q1212-3BC75-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V 3600 rpm, 4-pole 285 382 315 Δ 120.5 756 94.6 94.7 93.7 0.88 450 7.6 2.6 1■Q1222-3AB15-5■■■ 345 463 315 Δ 120.6 915 95.0 95.2 94.4 0.90 530 7.2 2.4 1■Q1222-3AB35-5■■■ 380 510 315 Δ 120.5 1008 95.2 95.4 94.7 0.90 580 8.2 2.7 1■Q1222-3AB55-5■■■ 1■Q1222-3AB75-5■■■ 425 570 315 Δ 120.4 1127 95.4 95.6 94.9 0.90 650 9.5 3.1 3000 rpm, 4-pole 445 597 355 Δ 100.5 1417 95.7 96.2 95.8 0.89 680 7.2 2.6 1■Q1222-3BB55-1■■■ 470 630 355 Δ 100.5 1496 95.7 96.3 96.0 0.89 720 6.3 2.3 1■Q1222-3BB75-1■■■ 1800 rpm, 4-pole 280 375 315 Δ 60.5 1486 95.3 96.0 95.9 0.86 445 7.9 2.9 1■Q1222-3AB15-6■■■ 350 469 315 Δ 60.5 1857 95.5 96.1 96.2 0.88 540 8.3 2.9 1■Q1222-3AB35-6■■■ 400 536 315 Δ 60.5 2122 95.7 96.4 96.4 0.89 610 8.5 3.0 1■Q1222-3AB55-6■■■ 460 617 315 Δ 60.5 2441 95.8 96.6 96.6 0.90 690 8.8 3.0 1■Q1222-3AB75-6■■■ 470 630 355 Δ 60.4 2494 95.9 96.7 96.7 0.88 720 8.2 3.1 1■Q1222-3BB55-6■■■ 520 697 355 Δ 60.4 2761 96.1 96.8 96.7 0.87 810 9.4 3.6 1■Q1222-3BB75-6■■■ 1200 rpm, 6-pole 250 335 315 Δ 60.5 1991 95.2 95.7 96.0 0.80 425 8.1 2.5 1■Q1222-3AC15-7■■■ 305 409 315 Δ 60.5 2428 95.3 95.7 96.1 0.83 500 7.8 2.4 1■Q1222-3AC35-7■■■ 345 463 315 Δ 60.5 2747 95.4 95.7 96.2 0.84 560 7.9 2.4 1■Q1222-3AC55-7■■■ 385 516 315 Δ 60.5 3065 95.5 96.3 96.4 0.85 620 7.6 2.3 1■Q1222-3AC75-7■■■ 400 536 355 Δ 60.3 3184 95.6 96.3 95.9 0.84 650 10.7 3.1 1■Q1222-3BC55-7■■■ 1■Q1222-3BC75-7■■■ 440 590 355 Δ 60.3 3502 95.7 96.3 96.0 0.85 710 10.6 2.8 900 rpm, 6-pole 200 268 315 Δ 45.5 2123 94.4 95.3 95.4 0.78 355 7.6 2.6 1■Q1222-3AC15-8■■■ 250 335 315 Δ 45.5 2654 94.6 95.5 95.7 0.81 425 7.5 2.5 1■Q1222-3AC35-8■■■ 280 375 315 Δ 45.5 2973 94.6 95.6 95.8 0.83 465 7.4 2.4 1■Q1222-3AC55-8■■■ 310 416 315 Δ 45.5 3291 94.6 95.7 95.9 0.85 500 7.0 2.2 1■Q1222-3AC75-8■■■ 355 476 355 Δ 45.4 3768 94.8 95.7 95.7 0.86 570 8.7 2.6 1■Q1222-3BC55-8■■■ 395 530 355 Δ 45.3 4193 95.0 95.9 95.8 0.85 640 9.4 2.4 1■Q1222-3BC75-8■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC75-8■■■ Prated 5/20 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency – low noise Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1212-3AB15-5... 1.Q1212-3AB35-5... 1.Q1212-3AB55-5... 1.Q1212-3AB75-5... 1310 1490 1670 1830 1360 1540 1720 1880 3.5 4.4 5 5.8 79 79 79 79 94.5 94.5 94.5 94.5 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 477 590 590 590 1.Q1212-3BB55-1... 1.Q1212-3BB75-1... 2300 2420 2350 2480 8.3 8.9 79 79 95 95 3300 3300 1XB7 740 1XB7 740 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 725 725 1.Q1212-3AB15-6... 1.Q1212-3AB35-6... 1.Q1212-3AB55-6... 1.Q1212-3AB75-6... 1.Q1212-3BB55-6... 1.Q1212-3BB75-6... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 477 590 590 725 725 725 1.Q1212-3AC15-7... 1.Q1212-3AC35-7... 1.Q1212-3AC55-7... 1.Q1212-3AC75-7... 1.Q1212-3BC55-7... 1.Q1212-3BC75-7... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-7LE33-8AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 370 477 590 590 590 725 1.Q1212-3AC15-8... 1.Q1212-3AC35-8... 1.Q1212-3AC55-8... 1.Q1212-3AC75-8... 1.Q1212-3BC55-8... 1.Q1212-3BC75-8... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LE33-8AA3 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 370 477 477 477 590 590 1.Q1222-3AB15-5... 1.Q1222-3AB35-5... 1.Q1222-3AB55-5... 1.Q1222-3AB75-5... 1310 1490 1670 1830 1360 1540 1720 1880 3.5 4.4 5 5.8 79 79 79 79 94.5 94.5 94.5 94.5 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 477 590 590 725 1.Q1222-3BB55-1... 1.Q1222-3BB75-1... 2300 2420 2350 2480 8.3 8.9 79 79 95 95 3300 3300 1XB7 740 1XB7 740 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 725 725 1.Q1222-3AB15-6... 1.Q1222-3AB35-6... 1.Q1222-3AB55-6... 1.Q1222-3AB75-6... 1.Q1222-3BB55-6... 1.Q1222-3BB75-6... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 477 590 725 725 725 820 1.Q1222-3AC15-7... 1.Q1222-3AC35-7... 1.Q1222-3AC55-7... 1.Q1222-3AC75-7... 1.Q1222-3BC55-7... 1.Q1222-3BC75-7... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 477 590 590 725 725 725 1.Q1222-3AC15-8... 1.Q1222-3AC35-8... 1.Q1222-3AC55-8... 1.Q1222-3AC75-8... 1.Q1222-3BC55-8... 1.Q1222-3BC75-8... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 370 477 477 590 590 725 Siemens D 81.8 · 04/2014 5 5/21 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency – increased output ■ Selection and ordering data 5 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V 3600 rpm, 4-pole 310 416 315 Δ 120.6 823 94.6 94.8 94.0 0.88 445 6.6 2.2 1■Q1312-3AB15-5■■■ 385 516 315 Δ 120.5 1021 95.1 95.3 94.6 0.89 550 7.7 2.6 1■Q1312-3AB35-5■■■ 410 550 315 Δ 120.6 1088 95.1 95.5 94.9 0.90 570 6.6 2.2 1■Q1312-3AB55-5■■■ 470 630 315 Δ 120.6 1247 95.4 95.8 95.2 0.91 650 7.1 2.3 1■Q1312-3AB75-5■■■ 3000 rpm, 4-pole 485 650 355 Δ 100.6 1544 95.6 96.3 96.0 0.89 680 5.7 2.0 1■Q1312-3BB55-1■■■ 1■Q1312-3BB75-1■■■ 540 724 355 Δ 100.5 1719 95.8 96.4 96.1 0.89 760 6.6 2.4 1800 rpm, 4-pole 300 402 315 Δ 60.5 1592 95.1 95.9 95.9 0.86 440 7.3 2.7 1■Q1312-3AB15-6■■■ 1■Q1312-3AB35-6■■■ 370 496 315 Δ 60.5 1963 95.3 96.1 96.2 0.89 520 7.6 2.7 1■Q1312-3AB55-6■■■ 415 557 315 Δ 60.5 2202 95.4 96.3 96.3 0.90 580 7.7 2.7 510 684 315 Δ 60.4 2706 95.9 96.6 96.6 0.88 720 9.4 2.7 1■Q1312-3AB75-6■■■ 555 744 355 Δ 60.4 2945 96.0 96.7 96.7 0.87 790 8.2 3.1 1■Q1312-3BB55-6■■■ 1■Q1312-3BB75-6■■■ 580 778 355 Δ 60.5 3078 95.9 96.7 96.8 0.89 810 7.5 2.8 1200 rpm, 6-pole 265 355 315 Δ 60.6 2111 94.7 95.6 95.8 0.82 405 6.7 2.0 1■Q1312-3AC15-7■■■ 315 422 315 Δ 60.5 2509 95.0 95.7 96.0 0.84 470 7.1 2.1 1■Q1312-3AC35-7■■■ 390 523 315 Δ 60.5 3105 95.2 96.1 96.2 0.84 580 7.4 2.2 1■Q1312-3AC55-7■■■ 1■Q1312-3AC75-7■■■ 420 563 315 Δ 60.5 3345 95.2 96.1 96.2 0.84 630 7.0 2.2 440 590 355 Δ 60.3 3502 95.6 96.3 96.0 0.85 650 9.9 2.8 1■Q1312-3BC55-7■■■ 1■Q1312-3BC75-7■■■ 485 650 355 Δ 60.3 3861 95.6 96.3 96.1 0.86 700 9.9 2.6 900 rpm, 6-pole 225 302 315 Δ 45.6 2389 93.9 95.1 95.4 0.81 350 6.7 2.2 1■Q1312-3AC15-8■■■ 1■Q1312-3AC35-8■■■ 280 375 315 Δ 45.5 2972 94.4 95.4 95.5 0.80 440 7.3 2.4 310 416 315 Δ 45.6 3289 94.2 95.3 95.6 0.84 465 6.5 2.1 1■Q1312-3AC55-8■■■ 1■Q1312-3AC75-8■■■ 340 456 315 Δ 45.5 3610 94.3 95.4 95.7 0.84 510 6.7 2.0 375 503 355 Δ 45.4 3981 94.6 95.6 95.7 0.87 540 7.9 2.5 1■Q1312-3BC55-8■■■ 420 563 355 Δ 45.4 4458 94.7 95.7 95.8 0.87 610 8.1 2.2 1■Q1312-3BC75-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V 3600 rpm, 4-pole 315 422 315 Δ 120.6 836 94.6 94.8 94.0 0.88 495 6.9 2.3 1■Q1322-3AB15-5■■■ 375 503 315 Δ 120.6 995 95.0 95.3 94.6 0.90 570 6.7 2.2 1■Q1322-3AB35-5■■■ 420 563 315 Δ 120.6 1114 95.2 95.5 94.9 0.90 640 7.4 2.4 1■Q1322-3AB55-5■■■ 1■Q1322-3AB75-5■■■ 475 637 315 Δ 120.5 1260 95.5 95.8 95.1 0.90 720 8.6 2.8 3000 rpm, 4-pole 490 657 355 Δ 100.5 1560 95.7 96.3 96.0 0.89 750 6.5 2.3 1■Q1322-3BB55-1■■■ 510 684 355 Δ 100.6 1624 95.7 96.4 96.1 0.89 780 5.8 2.1 1■Q1322-3BB75-1■■■ 1800 rpm, 4-pole 300 402 315 Δ 60.5 1592 95.1 95.9 95.9 0.86 475 7.4 2.7 1■Q1322-3AB15-6■■■ 375 503 315 Δ 60.5 1990 95.3 96.1 96.2 0.88 580 7.8 2.7 1■Q1322-3AB35-6■■■ 425 570 315 Δ 60.5 2255 95.5 96.3 96.4 0.89 650 8.0 2.8 1■Q1322-3AB55-6■■■ 490 657 315 Δ 60.5 2600 95.6 96.4 96.5 0.90 740 8.2 2.8 1■Q1322-3AB75-6■■■ 530 711 355 Δ 60.5 2812 95.8 96.7 96.7 0.89 810 7.2 2.7 1■Q1322-3BB55-6■■■ 595 798 355 Δ 60.4 3157 96.0 96.8 96.8 0.88 920 8.3 3.1 1■Q1322-3BB75-6■■■ 1200 rpm, 6-pole 280 375 315 Δ 60.5 2230 94.9 95.7 95.9 0.81 475 7.2 2.2 1■Q1322-3AC15-7■■■ 335 449 315 Δ 60.5 2668 95.0 95.7 96.1 0.83 550 7.1 2.2 1■Q1322-3AC35-7■■■ 380 510 315 Δ 60.5 3026 95.1 96.1 96.2 0.84 620 7.2 2.2 1■Q1322-3AC55-7■■■ 425 570 315 Δ 60.5 3384 95.2 96.1 96.3 0.85 680 7.0 2.1 1■Q1322-3AC75-7■■■ 435 583 355 Δ 60.3 3462 95.6 96.2 96.0 0.85 700 9.9 2.9 1■Q1322-3BC55-7■■■ 1■Q1322-3BC75-7■■■ 480 644 355 Δ 60.3 3821 95.6 96.3 96.1 0.86 760 9.9 2.6 900 rpm, 6-pole 220 295 315 Δ 45.5 2336 93.9 95.0 95.3 0.79 385 7.0 2.3 1■Q1322-3AC15-8■■■ 275 369 315 Δ 45.5 2919 94.2 95.3 95.5 0.82 460 6.9 2.2 1■Q1322-3AC35-8■■■ 310 416 315 Δ 45.5 3292 94.2 95.3 95.6 0.84 510 6.7 2.1 1■Q1322-3AC55-8■■■ 340 456 315 Δ 45.6 3608 94.2 95.4 95.7 0.85 550 6.4 2.0 1■Q1322-3AC75-8■■■ 370 496 355 Δ 45.4 3927 94.7 95.7 95.7 0.86 590 8.4 2.5 1■Q1322-3BC55-8■■■ 425 570 355 Δ 45.4 4511 94.9 95.8 95.8 0.86 680 8.9 2.2 1■Q1322-3BC75-8■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC75-8■■■ Prated 5/22 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency – increased output Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1312-3AB15-5... 1.Q1312-3AB35-5... 1.Q1312-3AB55-5... 1.Q1312-3AB75-5... 1310 1490 1670 1830 1360 1540 1720 1880 3.5 4.4 5 5.8 85 85 85 85 100.5 100.5 100.5 100.5 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 477 590 590 725 1.Q1312-3BB55-1... 1.Q1312-3BB75-1... 2300 2420 2350 2480 8.3 8.9 85 85 101 101 3300 3300 1XB7 740 1XB7 740 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 725 820 1.Q1312-3AB15-6... 1.Q1312-3AB35-6... 1.Q1312-3AB55-6... 1.Q1312-3AB75-6... 1.Q1312-3BB55-6... 1.Q1312-3BB75-6... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE38-4AA3 477 590 590 725 820 820 1.Q1312-3AC15-7... 1.Q1312-3AC35-7... 1.Q1312-3AC55-7... 1.Q1312-3AC75-7... 1.Q1312-3BC55-7... 1.Q1312-3BC75-7... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 477 477 590 725 725 725 1.Q1312-3AC15-8... 1.Q1312-3AC35-8... 1.Q1312-3AC55-8... 1.Q1312-3AC75-8... 1.Q1312-3BC55-8... 1.Q1312-3BC75-8... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-7LE33-8AA3 6SL3710-7LE35-0AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 370 477 477 590 590 725 1.Q1322-3AB15-5... 1.Q1322-3AB35-5... 1.Q1322-3AB55-5... 1.Q1322-3AB75-5... 1310 1490 1670 1830 1360 1540 1720 1880 3.5 4.4 5 5.8 85 85 85 85 100.5 100.5 100.5 100.5 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 590 590 725 725 1.Q1322-3BB55-1... 1.Q1322-3BB75-1... 2300 2420 2350 2480 8.3 8.9 85 85 101 101 3300 3300 1XB7 740 1XB7 740 6SL3710-1GE38-4AA3 6SL3710-1GE38-4AA3 820 820 1.Q1322-3AB15-6... 1.Q1322-3AB35-6... 1.Q1322-3AB55-6... 1.Q1322-3AB75-6... 1.Q1322-3BB55-6... 1.Q1322-3BB75-6... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 477 590 725 820 820 960 1.Q1322-3AC15-7... 1.Q1322-3AC35-7... 1.Q1322-3AC55-7... 1.Q1322-3AC75-7... 1.Q1322-3BC55-7... 1.Q1322-3BC75-7... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 477 590 725 725 725 820 1.Q1322-3AC15-8... 1.Q1322-3AC35-8... 1.Q1322-3AC55-8... 1.Q1322-3AC75-8... 1.Q1322-3BC55-8... 1.Q1322-3BC75-8... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 477 477 590 590 590 725 Siemens D 81.8 · 04/2014 5 5/23 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 460 V, 60 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V 1800 rpm, 4-pole 5 250 335 315 Δ 60.4 1326 95.5 96.2 96.0 0.85 370 8.7 3.2 1■Q1213-3AB15-6■■■ 350 469 315 Δ 60.5 1857 95.5 96.3 96.4 0.88 495 8.0 2.8 1■Q1213-3AB35-6■■■ 390 523 315 Δ 60.5 2069 95.6 96.4 96.5 0.89 550 8.1 2.8 1■Q1213-3AB55-6■■■ 480 644 315 Δ 60.4 2547 96.0 96.7 96.7 0.88 680 9.8 2.9 1■Q1213-3AB75-6■■■ 515 691 355 Δ 60.4 2732 96.2 97.0 97.0 0.86 740 8.7 3.4 1■Q1213-3BB55-6■■■ 540 724 355 Δ 60.4 2865 96.1 97.0 97.1 0.88 760 7.9 3.0 1■Q1213-3BB75-6■■■ 1200 rpm, 6-pole 240 322 315 Δ 60.5 1911 95.0 96.0 96.1 0.82 365 7.4 2.3 1■Q1213-3AC15-7■■■ 305 409 315 Δ 60.5 2429 95.2 96.1 96.3 0.83 460 7.2 2.2 1■Q1213-3AC35-7■■■ 360 483 315 Δ 60.5 2866 95.5 96.4 96.4 0.83 540 7.9 2.4 1■Q1213-3AC55-7■■■ 390 523 315 Δ 60.5 3105 95.4 96.4 96.4 0.84 580 7.6 2.3 1■Q1213-3AC75-7■■■ 435 583 355 Δ 60.3 3462 95.9 96.7 96.6 0.84 640 10.1 2.9 1■Q1213-3BC55-7■■■ 480 644 355 Δ 60.3 3821 96.0 96.7 96.6 0.85 700 9.9 2.6 1■Q1213-3BC75-7■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V 1800 rpm, 4-pole 245 329 315 Δ 60.4 1300 95.5 96.2 96.1 0.84 400 8.8 3.3 1■Q1223-3AB15-6■■■ 350 469 315 Δ 60.5 1857 95.5 96.3 96.4 0.88 540 8.3 2.9 1■Q1223-3AB35-6■■■ 400 536 315 Δ 60.5 2122 95.7 96.5 96.6 0.89 610 8.5 3.0 1■Q1223-3AB55-6■■■ 460 617 315 Δ 60.5 2441 95.8 96.6 96.7 0.90 690 8.8 3.0 1■Q1223-3AB75-6■■■ 490 657 355 Δ 60.4 2600 96.1 96.9 97.0 0.88 750 7.8 2.9 1■Q1223-3BB55-6■■■ 555 744 355 Δ 60.4 2945 96.3 97.1 97.1 0.87 860 8.8 3.4 1■Q1223-3BB75-6■■■ 1200 rpm, 6-pole 260 349 315 Δ 60.5 2070 95.2 96.1 96.1 0.80 445 7.7 2.4 1■Q1223-3AC15-7■■■ 310 416 315 Δ 60.5 2468 95.3 96.2 96.3 0.83 510 7.6 2.3 1■Q1223-3AC35-7■■■ 355 476 315 Δ 60.5 2826 95.4 96.3 96.4 0.84 580 7.6 2.3 1■Q1223-3AC55-7■■■ 395 530 315 Δ 60.5 3145 95.5 96.4 96.5 0.85 630 7.5 2.3 1■Q1223-3AC75-7■■■ 430 577 355 Δ 60.3 3422 95.9 96.7 96.6 0.84 690 10.0 2.9 1■Q1223-3BC55-7■■■ 470 630 355 Δ 60.3 3741 96.0 96.7 96.6 0.85 750 10.0 2.6 1■Q1223-3BC75-7■■■ For versions, see Article No. supplements and special versions 5/24 Siemens D 81.8 · 04/2014 1■M1223-3AC75-7■■■ © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 460 V, 60 Hz Premium Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1213-3AB15-6... 1310 1360 3.5 79 94.5 3000 1XB7 731 6SL3710-7LE33-8AA3 370 1.Q1213-3AB35-6... 1490 1540 4.4 79 94.5 3000 1XB7 731 6SL3710-7LE36-1AA3 590 1.Q1213-3AB55-6... 1670 1720 5 79 94.5 3000 1XB7 731 6SL3710-7LE36-1AA3 590 1.Q1213-3AB75-6... 1830 1880 5.8 79 94.5 3000 1XB7 740 6SL3710-7LE37-5AA3 725 1.Q1213-3BB55-6... 2300 2350 8.3 79 95 2600 1XB7 740 6SL3710-7LE38-4AA3 820 1.Q1213-3BB75-6... 2420 2480 8.9 79 95 2600 1XB7 740 6SL3710-7LE38-4AA3 820 1.Q1213-3AC15-7... 1340 1390 5.9 79 94.5 2600 1XB7 731 6SL3710-7LE33-8AA3 370 1.Q1213-3AC35-7... 1520 1570 7.2 79 94.5 2600 1XB7 731 6SL3710-7LE35-0AA3 477 1.Q1213-3AC55-7... 1700 1750 8.3 79 94.5 2600 1XB7 731 6SL3710-7LE36-1AA3 590 1.Q1213-3AC75-7... 1810 1860 9.1 79 94.5 2600 1XB7 731 6SL3710-7LE36-1AA3 590 1.Q1213-3BC55-7... 2290 2350 14.5 79 95 2500 1XB7 740 6SL3710-7LE37-5AA3 725 1.Q1213-3BC75-7... 2440 2490 16 79 95 2500 1XB7 740 6SL3710-7LE37-5AA3 725 1.Q1223-3AB15-6... 1310 1360 3.5 79 94.5 3000 1XB7 731 6SL3710-1GE35-0AA3 477 1.Q1223-3AB35-6... 1490 1540 4.4 79 94.5 3000 1XB7 731 6SL3710-1GE36-1AA3 590 1.Q1223-3AB55-6... 1670 1720 5 79 94.5 3000 1XB7 740 6SL3710-1GE37-5AA3 725 1.Q1223-3AB75-6... 1830 1880 5.8 79 94.5 3000 1XB7 740 6SL3710-1GE37-5AA3 725 1.Q1223-3BB55-6... 2300 2350 8.3 79 95 2600 1XB7 740 6SL3710-1GE38-4AA3 820 1.Q1223-3BB75-6... 2420 2480 8.9 79 95 2600 1XB7 740 6SL3710-1GE41-0AA3 960 1.Q1223-3AC15-7... 1340 1390 5.9 79 94.5 2600 1XB7 731 6SL3710-1GE35-0AA3 477 1.Q1223-3AC35-7... 1520 1570 7.2 79 94.5 2600 1XB7 731 6SL3710-1GE36-1AA3 590 1.Q1223-3AC55-7... 1700 1750 8.3 79 94.5 2600 1XB7 731 6SL3710-1GE36-1AA3 590 1.Q1223-3AC75-7... 1810 1860 9.1 79 94.5 2600 1XB7 740 6SL3710-1GE37-5AA3 725 1.Q1223-3BC55-7... 2290 2350 14.5 79 95 2500 1XB7 740 6SL3710-1GE37-5AA3 725 1.Q1223-3BC75-7... 2440 2490 16 79 95 2500 1XB7 740 6SL3710-1GE38-4AA3 820 Siemens D 81.8 · 04/2014 5 5/25 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency – low noise ■ Selection and ordering data 5 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V 3600 rpm, 4-pole 270 362 315 Δ 120.6 717 94.3 94.5 93.6 0.88 305 6.9 2.3 1■Q1212-3AB16-5■■■ 1■Q1212-3AB36-5■■■ 335 449 315 Δ 120.5 889 94.9 95.0 94.2 0.89 375 8.6 2.9 370 496 315 Δ 120.5 982 95.1 95.3 94.5 0.89 415 9.0 3.0 1■Q1212-3AB56-5■■■ 425 570 315 Δ 120.5 1127 95.4 95.6 94.8 0.90 470 9.3 3.0 1■Q1212-3AB76-5■■■ 1■Q1212-3BB56-1■■■ 435 583 355 Δ 100.6 1385 95.5 96.1 95.8 0.89 480 6.2 2.2 475 637 355 Δ 100.5 1512 95.7 96.3 95.9 0.89 520 6.8 2.4 1■Q1212-3BB76-1■■■ 1800 rpm, 4-pole 255 342 315 Δ 60.5 1353 95.1 95.8 95.8 0.87 290 7.9 2.8 1■Q1212-3AB16-6■■■ 330 443 315 Δ 60.4 1751 95.6 96.1 96.1 0.86 380 9.4 3.4 1■Q1212-3AB36-6■■■ 370 496 315 Δ 60.4 1963 95.6 96.1 96.3 0.88 415 9.1 3.2 1■Q1212-3AB56-6■■■ 440 590 315 Δ 60.4 2336 95.9 96.6 96.5 0.87 495 10.5 3.2 1■Q1212-3AB76-6■■■ 450 603 355 Δ 60.3 2389 96.0 96.7 96.5 0.86 510 9.7 3.7 1■Q1212-3BB56-6■■■ 480 644 355 Δ 60.3 2548 96.1 96.7 96.5 0.85 550 10.8 3.9 1■Q1212-3BB76-6■■■ 1200 rpm, 6-pole 230 308 315 Δ 60.5 1831 95.0 95.7 95.8 0.81 280 8.2 2.5 1■Q1212-3AC16-7■■■ 280 375 315 Δ 60.4 2229 95.2 95.7 96.0 0.82 335 8.5 2.6 1■Q1212-3AC36-7■■■ 315 422 315 Δ 60.5 2508 95.3 95.7 96.1 0.84 370 8.1 2.5 1■Q1212-3AC56-7■■■ 1■Q1212-3AC76-7■■■ 350 469 315 Δ 60.4 2786 95.4 95.7 96.2 0.84 410 8.3 2.5 365 489 355 Δ 60.3 2905 95.6 95.7 95.6 0.81 445 12.3 3.4 1■Q1212-3BC56-7■■■ 400 536 355 Δ 60.3 3184 95.6 96.2 95.8 0.83 475 11.9 3.1 1■Q1212-3BC76-7■■■ 900 rpm, 6-pole 180 241 315 Y 45.4 1911 94.2 95.2 95.3 0.80 225 7.9 2.6 1■Q1212-3AC16-8■■■ 235 315 315 Δ 45.4 2494 94.7 95.5 95.5 0.79 295 8.3 2.8 1■Q1212-3AC36-8■■■ 265 355 315 Δ 45.4 2813 94.6 95.6 95.7 0.83 315 7.8 2.5 1■Q1212-3AC56-8■■■ 285 382 315 Δ 45.4 3024 94.8 95.7 95.7 0.82 345 8.5 2.4 1■Q1212-3AC76-8■■■ 330 443 355 Δ 45.3 3503 94.8 95.6 95.6 0.85 385 9.5 2.8 1■Q1212-3BC56-8■■■ 365 489 355 Δ 45.3 3874 94.9 95.7 95.6 0.85 425 9.5 2.6 1■Q1212-3BC76-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V 3600 rpm, 4-pole 265 355 315 Δ 120.5 703 94.4 94.4 93.4 0.88 335 8.3 2.8 1■Q1222-3AB16-5■■■ 1■Q1222-3AB36-5■■■ 315 422 315 Δ 120.4 836 94.8 94.9 93.9 0.89 390 9.5 3.1 345 463 315 Δ 120.4 916 95.0 95.1 94.2 0.89 430 10.2 3.4 1■Q1222-3AB56-5■■■ 400 536 315 Δ 120.5 1061 95.2 95.5 94.8 0.91 485 8.0 2.6 1■Q1222-3AB76-5■■■ 1800 rpm, 4-pole 415 557 355 Δ 100.5 1321 95.6 96.1 95.7 0.89 510 6.7 2.4 1■Q1222-3BB56-1■■■ 450 603 355 Δ 100.4 1433 95.7 96.2 95.8 0.89 550 7.6 2.7 1■Q1222-3BB76-1■■■ 3000 rpm, 4-pole 250 335 315 Δ 60.5 1327 95.0 95.8 95.8 0.88 310 7.7 2.7 1■Q1222-3AB16-6■■■ 325 436 315 Δ 60.4 1724 95.5 96.1 96.1 0.87 410 9.2 3.3 1■Q1222-3AB36-6■■■ 365 489 315 Δ 60.4 1937 95.6 96.1 96.3 0.89 450 9.2 3.2 1■Q1222-3AB56-6■■■ 435 583 315 Δ 60.4 2310 95.9 96.6 96.5 0.87 540 11.0 3.2 1■Q1222-3AB76-6■■■ 470 630 355 Δ 60.4 2493 96.0 96.7 96.6 0.88 580 9.1 3.4 1■Q1222-3BB76-6■■■ 1200 rpm, 6-pole 215 288 315 Δ 60.5 1712 94.8 95.7 95.8 0.82 290 7.6 2.4 1■Q1222-3AC16-7■■■ 275 369 315 Δ 60.4 2189 95.2 95.7 96.0 0.82 365 8.5 2.6 1■Q1222-3AC36-7■■■ 315 422 315 Δ 60.5 2508 95.3 95.7 96.1 0.84 410 8.1 2.5 1■Q1222-3AC56-7■■■ 1■Q1222-3AC76-7■■■ 345 463 315 Δ 60.4 2746 95.4 95.7 96.2 0.84 450 8.6 2.6 355 476 355 Δ 60.3 2826 95.5 95.7 95.7 0.83 465 11.9 3.5 1■Q1222-3BC56-7■■■ 375 503 355 Δ 60.2 2986 95.6 95.7 95.5 0.80 510 13.4 3.3 1■Q1222-3BC76-7■■■ 900 rpm, 6-pole 180 241 315 Δ 45.4 1910 94.3 95.2 95.2 0.77 260 8.3 2.8 1■Q1222-3AC16-8■■■ 225 302 315 Δ 45.4 2388 94.6 95.4 95.4 0.77 320 8.7 3.0 1■Q1222-3AC36-8■■■ 260 349 315 Δ 45.4 2759 94.6 95.6 95.6 0.82 350 8.2 2.7 1■Q1222-3AC56-8■■■ 285 382 315 Δ 45.4 3025 94.8 95.7 95.7 0.82 380 8.4 2.4 1■Q1222-3AC76-8■■■ 325 436 355 Δ 45.3 3450 94.8 95.6 95.6 0.85 420 9.4 2.9 1■Q1222-3BC56-8■■■ 350 469 355 Δ 45.3 3715 94.9 95.7 95.6 0.85 450 10.0 2.7 1■Q1222-3BC76-8■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC76-8■■■ Prated 5/26 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency – low noise Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1212-3AB16-5... 1.Q1212-3AB36-5... 1.Q1212-3AB56-5... 1.Q1212-3AB76-5... 1.Q1212-3BB56-1... 1.Q1212-3BB76-1... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 320 400 452 560 560 560 1.Q1212-3AB16-6... 1.Q1212-3AB36-6... 1.Q1212-3AB56-6... 1.Q1212-3AB76-6... 1.Q1212-3BB56-6... 1.Q1212-3BB76-6... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 320 400 452 560 560 560 1.Q1212-3AC16-7... 1.Q1212-3AC36-7... 1.Q1212-3AC56-7... 1.Q1212-3AC76-7... 1.Q1212-3BC56-7... 1.Q1212-3BC76-7... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 320 400 400 452 452 560 1.Q1212-3AC16-8... 1.Q1212-3AC36-8... 1.Q1212-3AC56-8... 1.Q1212-3AC76-8... 1.Q1212-3BC56-8... 1.Q1212-3BC76-8... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 250 320 320 400 400 452 1.Q1222-3AB16-5... 1.Q1222-3AB36-5... 1.Q1222-3AB56-5... 1.Q1222-3AB76-5... 1310 1490 1670 1830 1360 1540 1720 1880 3.5 4.4 5 5.8 79 79 79 79 94.5 94.5 94.5 94.5 3600 3600 3600 3600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GF34-1AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 400 400 452 560 1.Q1222-3BB56-1... 1.Q1222-3BB76-1... 2300 2420 2350 2480 8.3 8.9 79 79 95 95 3300 3300 1XB7 731 1XB7 731 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 560 560 1.Q1222-3AB16-6... 1.Q1222-3AB36-6... 1.Q1222-3AB56-6... 1.Q1222-3AB76-6... 1.Q1222-3BB76-6... 1310 1490 1670 1830 2420 1360 1540 1720 1880 2480 3.5 4.4 5 5.8 8.9 79 79 79 79 79 94.5 94.5 94.5 94.5 95 3000 3000 3000 3000 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GF33-3AA3 6SL3710-1GF34-7AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 320 452 452 560 710 1.Q1222-3AC16-7... 1.Q1222-3AC36-7... 1.Q1222-3AC56-7... 1.Q1222-3AC76-7... 1.Q1222-3BC56-7... 1.Q1222-3BC76-7... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GF33-3AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 320 400 452 452 560 560 1.Q1222-3AC16-8... 1.Q1222-3AC36-8... 1.Q1222-3AC56-8... 1.Q1222-3AC76-8... 1.Q1222-3BC56-8... 1.Q1222-3BC76-8... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GF33-3AA3 6SL3710-1GF33-3AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF34-7AA3 320 320 400 400 452 452 Siemens D 81.8 · 04/2014 5 5/27 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency – increased output ■ Selection and ordering data 5 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V 3600 rpm, 4-pole 295 396 315 Δ 120.6 783 94.3 94.6 93.8 0.88 335 6.3 2.1 1■Q1312-3AB16-5■■■ 375 503 315 Δ 120.5 995 95.0 95.2 94.5 0.89 420 7.7 2.6 1■Q1312-3AB36-5■■■ 410 550 315 Δ 120.5 1088 95.2 95.4 94.7 0.90 450 8.3 2.7 1■Q1312-3AB56-5■■■ 470 630 315 Δ 120.5 1247 95.4 95.7 95.1 0.90 520 8.4 2.7 1■Q1312-3AB76-5■■■ 3000 rpm, 4-pole 470 630 355 Δ 100.6 1497 95.5 96.1 95.9 0.89 520 5.7 2.0 1■Q1312-3BB56-1■■■ 1■Q1312-3BB76-1■■■ 510 684 355 Δ 100.5 1624 95.7 96.3 96.0 0.89 560 6.3 2.3 1800 rpm, 4-pole 270 362 315 Δ 60.5 1433 94.9 95.7 95.7 0.87 305 7.5 2.7 1■Q1312-3AB16-6■■■ 1■Q1312-3AB36-6■■■ 355 476 315 Δ 60.5 1883 95.4 96.1 96.1 0.87 400 8.9 3.2 1■Q1312-3AB56-6■■■ 395 530 315 Δ 60.5 2096 95.4 96.2 96.3 0.89 435 8.7 3.0 475 637 315 Δ 60.4 2520 95.8 96.5 96.5 0.88 530 9.8 2.9 1■Q1312-3AB76-6■■■ 515 691 355 Δ 60.4 2732 95.9 96.6 96.6 0.87 580 8.5 3.3 1■Q1312-3BB56-6■■■ 1■Q1312-3BB76-6■■■ 560 751 355 Δ 60.4 2973 96.0 96.7 96.6 0.86 640 9.3 3.3 1200 rpm, 6-pole 255 342 315 Δ 60.5 2031 94.7 95.6 95.7 0.81 310 7.4 2.3 1■Q1312-3AC16-7■■■ 310 416 315 Δ 60.5 2468 94.9 95.7 95.9 0.83 370 7.7 2.3 1■Q1312-3AC36-7■■■ 350 469 315 Δ 60.5 2787 94.9 95.7 96.0 0.84 410 7.3 2.2 1■Q1312-3AC56-7■■■ 1■Q1312-3AC76-7■■■ 385 516 315 Δ 60.5 3065 95.1 96.0 96.1 0.84 450 7.5 2.3 405 543 355 Δ 60.3 3223 95.5 96.1 95.8 0.82 485 11.2 3.1 1■Q1312-3BC56-7■■■ 1■Q1312-3BC76-7■■■ 445 597 355 Δ 60.3 3542 95.5 96.2 95.9 0.84 520 10.8 2.8 900 rpm, 6-pole 200 268 315 Y 45.5 2124 93.7 94.8 95.1 0.81 245 7.3 2.3 1■Q1312-3AC16-8■■■ 1■Q1312-3AC36-8■■■ 255 342 315 Δ 45.5 2707 94.3 95.3 95.4 0.80 315 7.8 2.6 290 389 315 Δ 45.5 3079 94.2 95.3 95.6 0.84 345 7.2 2.3 1■Q1312-3AC56-8■■■ 1■Q1312-3AC76-8■■■ 320 429 315 Δ 45.5 3397 94.4 95.4 95.6 0.83 385 7.6 2.2 345 463 355 Δ 45.4 3662 94.7 95.6 95.6 0.85 400 9.1 2.7 1■Q1312-3BC56-8■■■ 390 523 355 Δ 45.4 4140 94.7 95.6 95.6 0.86 450 9.0 2.4 1■Q1312-3BC76-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V 3600 rpm, 4-pole 295 396 315 Δ 120.5 783 94.5 94.6 93.8 0.88 370 7.5 2.5 1■Q1322-3AB16-5■■■ 355 476 315 Δ 120.5 942 94.9 95.1 94.3 0.89 440 8.4 2.8 1■Q1322-3AB36-5■■■ 390 523 315 Δ 120.5 1035 95.1 95.3 94.5 0.89 485 9.1 3.0 1■Q1322-3AB56-5■■■ 1■Q1322-3AB76-5■■■ 440 590 315 Δ 120.6 1167 95.2 95.6 95.0 0.91 530 7.3 2.4 3000 rpm, 4-pole 455 610 355 Δ 100.6 1449 95.5 96.2 95.8 0.89 560 6.1 2.2 1■Q1322-3BB56-1■■■ 495 664 355 Δ 100.5 1576 95.7 96.3 95.9 0.89 610 6.9 2.5 1■Q1322-3BB76-1■■■ 1800 rpm, 4-pole 270 362 315 Δ 60.6 1433 94.7 95.6 95.7 0.88 335 7.1 2.5 1■Q1322-3AB16-6■■■ 345 463 315 Δ 60.5 1830 95.3 96.1 96.0 0.87 435 8.7 3.1 1■Q1322-3AB36-6■■■ 390 523 315 Δ 60.5 2069 95.4 96.2 96.3 0.89 480 8.6 3.0 1■Q1322-3AB56-6■■■ 470 630 315 Δ 60.4 2496 95.8 96.5 96.4 0.87 590 10.0 3.0 1■Q1322-3AB76-6■■■ 505 677 355 Δ 60.4 2679 95.9 96.7 96.6 0.87 630 9.0 3.4 1■Q1322-3BB56-6■■■ 535 717 355 Δ 60.4 2839 95.9 96.7 96.7 0.89 650 8.1 3.0 1■Q1322-3BB76-6■■■ 1200 rpm, 6-pole 240 322 315 Δ 60.6 1912 94.4 95.5 95.7 0.83 320 6.9 2.1 1■Q1322-3AC16-7■■■ 300 402 315 Δ 60.5 2389 95.0 95.7 95.9 0.83 395 7.9 2.4 1■Q1322-3AC36-7■■■ 345 463 315 Δ 60.5 2747 95.0 95.7 96.0 0.84 450 7.4 2.2 1■Q1322-3AC56-7■■■ 390 523 315 Δ 60.5 3105 95.1 96.0 96.1 0.84 510 7.6 2.3 1■Q1322-3AC76-7■■■ 395 530 355 Δ 60.3 3144 95.5 96.1 95.8 0.84 510 10.8 3.1 1■Q1322-3BC56-7■■■ 1■Q1322-3BC76-7■■■ 420 563 355 Δ 60.3 3343 95.6 96.1 95.7 0.82 560 12.2 3.0 900 rpm, 6-pole 200 268 315 Δ 45.5 2123 93.9 94.9 95.1 0.78 285 7.6 2.6 1■Q1322-3AC16-8■■■ 250 335 315 Δ 45.4 2654 94.3 95.2 95.3 0.79 350 7.9 2.7 1■Q1322-3AC36-8■■■ 290 389 315 Δ 45.5 3079 94.2 95.3 95.5 0.83 385 7.4 2.4 1■Q1322-3AC56-8■■■ 315 422 315 Δ 45.5 3344 94.4 95.4 95.6 0.83 420 7.6 2.2 1■Q1322-3AC76-8■■■ 345 463 355 Δ 45.4 3662 94.6 95.6 95.6 0.86 440 9.0 2.7 1■Q1322-3BC56-8■■■ 380 510 355 Δ 45.3 4033 94.8 95.7 95.6 0.86 485 9.3 2.5 1■Q1322-3BC76-8■■■ For versions, see Article No. supplements and special versions 1■M1222-3AC76-8■■■ Prated 5/28 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency – increased output Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1312-3AB16-5... 1.Q1312-3AB36-5... 1.Q1312-3AB56-5... 1.Q1312-3AB76-5... 1310 1490 1670 1830 1360 1540 1720 1880 3.5 4.4 5 5.8 85 85 85 85 100.5 100.5 100.5 100.5 3600 3600 3600 3600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 400 452 452 560 1.Q1312-3BB56-1... 1.Q1312-3BB76-1... 2300 2420 2350 2480 8.3 8.9 85 85 101 101 3300 3300 1XB7 731 1XB7 731 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 560 560 1.Q1312-3AB16-6... 1.Q1312-3AB36-6... 1.Q1312-3AB56-6... 1.Q1312-3AB76-6... 1.Q1312-3BB56-6... 1.Q1312-3BB76-6... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 320 400 452 560 710 710 1.Q1312-3AC16-7... 1.Q1312-3AC36-7... 1.Q1312-3AC56-7... 1.Q1312-3AC76-7... 1.Q1312-3BC56-7... 1.Q1312-3BC76-7... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 320 400 452 452 560 560 1.Q1312-3AC16-8... 1.Q1312-3AC36-8... 1.Q1312-3AC56-8... 1.Q1312-3AC76-8... 1.Q1312-3BC56-8... 1.Q1312-3BC76-8... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 250 320 400 400 400 452 1.Q1322-3AB16-5... 1.Q1322-3AB36-5... 1.Q1322-3AB56-5... 1.Q1322-3AB76-5... 1310 1490 1670 1830 1360 1540 1720 1880 3.5 4.4 5 5.8 85 85 85 85 100.5 100.5 100.5 100.5 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 400 452 560 560 1.Q1322-3BB56-1... 1.Q1322-3BB76-1... 2300 2420 2350 2480 8.3 8.9 85 85 101 101 3300 3300 1XB7 731 1XB7 740 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 560 710 1.Q1322-3AB16-6... 1.Q1322-3AB36-6... 1.Q1322-3AB56-6... 1.Q1322-3AB76-6... 1.Q1322-3BB56-6... 1.Q1322-3BB76-6... 1310 1490 1670 1830 2300 2420 1360 1540 1720 1880 2350 2480 3.5 4.4 5 5.8 8.3 8.9 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 400 452 560 710 710 710 1.Q1322-3AC16-7... 1.Q1322-3AC36-7... 1.Q1322-3AC56-7... 1.Q1322-3AC76-7... 1.Q1322-3BC56-7... 1.Q1322-3BC76-7... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GF33-3AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 320 400 452 560 560 560 1.Q1322-3AC16-8... 1.Q1322-3AC36-8... 1.Q1322-3AC56-8... 1.Q1322-3AC76-8... 1.Q1322-3BC56-8... 1.Q1322-3BC76-8... 1340 1520 1700 1810 2290 2440 1390 1570 1750 1860 2350 2490 5.9 7.2 8.3 9.1 14.5 16 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GF33-3AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 320 400 400 452 452 560 Siemens D 81.8 · 04/2014 5 5/29 © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 575 V, 60 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LQ1/1MQ1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V 1800 rpm, 4-pole 5 235 315 315 Δ 60.4 1247 95.2 96.2 95.9 0.86 270 8.5 3.1 1■Q1213-3AB16-6■■■ 330 443 315 Δ 60.4 1751 95.6 96.3 96.2 0.86 375 9.4 3.4 1■Q1213-3AB36-6■■■ 370 496 315 Δ 60.4 1963 95.7 96.4 96.5 0.88 415 9.1 3.2 1■Q1213-3AB56-6■■■ 440 590 315 Δ 60.4 2336 95.9 96.6 96.6 0.87 495 10.3 3.2 1■Q1213-3AB76-6■■■ 480 644 355 Δ 60.4 2549 96.2 97.0 96.9 0.86 540 9.2 3.5 1■Q1213-3BB56-6■■■ 520 697 355 Δ 60.3 2761 96.3 97.0 97.0 0.85 600 9.9 3.6 1■Q1213-3BB76-6■■■ 1200 rpm, 6-pole 240 322 315 Δ 60.5 1911 95.0 95.9 96.0 0.81 290 8.0 2.5 1■Q1213-3AC16-7■■■ 285 382 315 Δ 60.4 2269 95.2 96.1 96.1 0.82 340 8.3 2.6 1■Q1213-3AC36-7■■■ 325 436 315 Δ 60.5 2588 95.2 96.2 96.3 0.84 380 7.8 2.4 1■Q1213-3AC56-7■■■ 355 476 315 Δ 60.4 2826 95.4 96.3 96.3 0.84 415 8.1 2.5 1■Q1213-3AC76-7■■■ 400 536 355 Δ 60.3 3183 95.9 96.6 96.4 0.81 485 11.2 3.1 1■Q1213-3BC56-7■■■ 440 590 355 Δ 60.3 3502 95.9 96.6 96.5 0.83 520 10.8 2.8 1■Q1213-3BC76-7■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V 1800 rpm, 4-pole 220 295 315 Δ 60.5 1167 95.3 96.2 95.9 0.86 280 8.4 3.1 1■Q1223-3AB16-6■■■ 315 422 315 Δ 60.4 1671 95.6 96.3 96.2 0.86 400 9.4 3.4 1■Q1223-3AB36-6■■■ 365 489 315 Δ 60.4 1937 95.7 96.4 96.4 0.88 450 9.2 3.2 1■Q1223-3AB56-6■■■ 435 583 315 Δ 60.4 2310 96.0 96.7 96.6 0.86 550 10.6 3.2 1■Q1223-3AB76-6■■■ 470 630 355 Δ 60.3 2495 96.2 97.0 96.9 0.85 600 9.4 3.7 1■Q1223-3BB56-6■■■ 495 664 355 Δ 60.4 2626 96.1 97.0 97.0 0.88 610 8.7 3.3 1■Q1223-3BB76-6■■■ 1200 rpm, 6-pole 220 295 315 Δ 60.5 1752 94.8 95.8 95.9 0.82 295 7.5 2.3 1■Q1223-3AC16-7■■■ 280 375 315 Δ 60.4 2229 95.2 96.1 96.1 0.82 375 8.2 2.6 1■Q1223-3AC36-7■■■ 320 429 315 Δ 60.5 2548 95.3 96.2 96.3 0.84 415 8.0 2.4 1■Q1223-3AC56-7■■■ 360 483 315 Δ 60.4 2866 95.4 96.3 96.3 0.84 465 8.3 2.5 1■Q1223-3AC76-7■■■ 385 516 355 Δ 60.3 3064 95.9 96.6 96.4 0.82 510 10.8 3.2 1■Q1223-3BC56-7■■■ 415 557 355 Δ 60.3 3303 96.0 96.6 96.4 0.80 560 12.2 3.0 1■Q1223-3BC76-7■■■ For versions, see Article No. supplements and special versions 5/30 Siemens D 81.8 · 04/2014 1■M1223-3AC76-7■■■ © Siemens AG 2014 Forced-air cooled motors — enclosed version 1LQ1/1MQ1 motors for converter-fed operation Line voltage 575 V, 60 Hz Premium Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.Q1213-3AB16-6... 1310 1360 3.5 79 94.5 3000 1XB7 730 6SL3710-7LG33-3AA3 320 1.Q1213-3AB36-6... 1490 1540 4.4 79 94.5 3000 1XB7 731 6SL3710-7LG34-1AA3 400 1.Q1213-3AB56-6... 1670 1720 5 79 94.5 3000 1XB7 731 6SL3710-7LG34-7AA3 452 1.Q1213-3AB76-6... 1830 1880 5.8 79 94.5 3000 1XB7 731 6SL3710-7LG35-8AA3 560 1.Q1213-3BB56-6... 2300 2350 8.3 79 95 2600 1XB7 731 6SL3710-7LG35-8AA3 560 1.Q1213-3BB76-6... 2420 2480 8.9 79 95 2600 1XB7 740 6SL3710-7LG37-4AA3 710 1.Q1213-3AC16-7... 1340 1390 5.9 79 94.5 2600 1XB7 730 6SL3710-7LG33-3AA3 320 1.Q1213-3AC36-7... 1520 1570 7.2 79 94.5 2600 1XB7 730 6SL3710-7LG34-1AA3 400 1.Q1213-3AC56-7... 1700 1750 8.3 79 94.5 2600 1XB7 731 6SL3710-7LG34-1AA3 400 1.Q1213-3AC76-7... 1810 1860 9.1 79 94.5 2600 1XB7 731 6SL3710-7LG34-7AA3 452 1.Q1213-3BC56-7... 2290 2350 14.5 79 95 2500 1XB7 731 6SL3710-7LG35-8AA3 560 1.Q1213-3BC76-7... 2440 2490 16 79 95 2500 1XB7 731 6SL3710-7LG35-8AA3 560 1.Q1223-3AB16-6... 1310 1360 3.5 79 94.5 3000 1XB7 730 6SL3710-1GF33-3AA3 320 1.Q1223-3AB36-6... 1490 1540 4.4 79 94.5 3000 1XB7 731 6SL3710-1GF34-1AA3 400 1.Q1223-3AB56-6... 1670 1720 5 79 94.5 3000 1XB7 731 6SL3710-1GF34-7AA3 452 1.Q1223-3AB76-6... 1830 1880 5.8 79 94.5 3000 1XB7 731 6SL3710-1GF35-8AA3 560 1.Q1223-3BB56-6... 2300 2350 8.3 79 95 2600 1XB7 740 6SL3710-1GF37-4AA3 710 1.Q1223-3BB76-6... 2420 2480 8.9 79 95 2600 1XB7 740 6SL3710-1GF37-4AA3 710 1.Q1223-3AC16-7... 1340 1390 5.9 79 94.5 2600 1XB7 730 6SL3710-1GF33-3AA3 320 1.Q1223-3AC36-7... 1520 1570 7.2 79 94.5 2600 1XB7 731 6SL3710-1GF34-1AA3 400 1.Q1223-3AC56-7... 1700 1750 8.3 79 94.5 2600 1XB7 731 6SL3710-1GF34-7AA3 452 1.Q1223-3AC76-7... 1810 1860 9.1 79 94.5 2600 1XB7 731 6SL3710-1GF35-8AA3 560 1.Q1223-3BC56-7... 2290 2350 14.5 79 95 2500 1XB7 731 6SL3710-1GF35-8AA3 560 1.Q1223-3BC76-7... 2440 2490 16 79 95 2500 1XB7 731 6SL3710-1GF35-8AA3 560 Siemens D 81.8 · 04/2014 5 5/31 © Siemens AG 2014 Forced-air cooled motors — enclosed version Dimensions 1LQ1/1MQ1 motors Radially mounted equipment unit ■ Dimensional drawings IM B3 type of construction For terminal box dimensions, see Page 5/35. HC L HB' HK LL BE HD ØD F HB AC AG AD BC GA EB H HA 5 DB BA E G_D081_XX_00424 C B BB ØK Ø K' AA A AB IM B35 and IM V1 types of construction For flange dimensions, see Page 5/34 (Z = the number of retaining holes), For terminal box dimensions, see Page 5/35 L HC LM HB' LL HK HH T HB ØP ØN ØD F HD AG AC ZxS E GA AD BE M H HA EB DB G_D081_XX_00425 BA LA LE ØK C Ø K' B BB AA A AB Frame No. of size poles Motor type 315 1.Q12..-3A.1.-.... 560 120 680 1155 630 180 780 180 315 28 1.Q12..-3A.3.-.... ● 560 120 680 1155 630 180 780 200 315 28 28 35 1450 1670 85 M20 170 140 22 90 28 35 1470 1690 95 M24 170 140 25 100 1.Q12..-3A.5.-.... 560 120 680 1155 835 180 985 180 315 28 1.Q12..-3A.7.-.... ● 560 120 680 1155 835 180 985 200 315 28 28 35 1590 1810 85 M20 170 140 22 90 28 35 1610 1830 95 M24 170 140 25 100 1.Q13.-3A.1.-…. 1.Q13.-3A.3.-…. 560 120 680 1245 630 180 780 180 315 28 28 35 1450 1765 85 M20 170 140 22 90 ● 560 120 680 1245 630 180 780 200 315 28 28 35 1470 1785 95 M24 170 140 25 100 560 120 680 1245 835 180 985 180 315 28 28 35 1590 1905 85 M20 170 140 22 90 ● 560 120 680 1245 835 180 985 200 315 28 28 35 1610 1925 95 M24 170 140 25 100 630 150 780 1305 800 220 980 200 355 35 35 42 1725 1975 95 M24 170 140 25 100 4, 6 A 1.Q13.-3A.5.-…. 1.Q13.-3A.7.-…. 355 4, 6 Dimension designation acc. to IEC AA AB AC BA BB C H HA K 1.Q12.-3A.5.-…. 1.Q12.-3A.7.-…. ● 630 150 780 1305 800 220 980 224 355 35 1.Q13.-3A.5.-…. 1.Q13.-3A.7.-…. ● 630 150 780 1305 800 220 980 224 355 25 630 150 780 1305 800 220 980 200 355 35 ● Bearing design for increased cantilever forces, for type of construction IM B3 only. 5/32 B Siemens D 81.8 · 04/2014 1) K' L 1) LM1) D DB E EB F GA 35 42 1790 2040 100 M24 210 180 28 106 35 42 1725 2075 95 M24 170 140 25 100 35 42 1790 2140 100 M24 210 180 28 106 With type of construction IM V1, dimensions L or LM may increase due to a protective cover for the fan motor. © Siemens AG 2014 Forced-air cooled motors — enclosed version Dimensions 1LQ1/1MQ1 motors Axially mounted equipment unit ■ Dimensional drawings IM B3 type of construction For terminal box dimensions, see Page 5/35. L LL BE HB' HK HC GA HD AC ØD F HB AG AD BC BA E 5 H HA EB DB G_D081_XX_00418 C ØK B BB Ø K' AA A AB IM B35 and IM V1 types of construction For flange dimensions, see Page 5/34 (Z = the number of retaining holes), For terminal box dimensions, see Page 5/35 L LL HC HB' HK HH BE AG AD LM HB ZxS GA AQ AC ØP ØN ØD F E DB G_D081_XX_00419 BA LA LE C Frame No. of size poles Motor type 315 1.Q12..-3A.1.-.... 1.Q12..-3A.3.-.... 4, 6 4, 6 1.Q12..-3A.5.-…. 1.Q12..-3A.7.-…. ØK Ø K' B BB AA A AB Dimension designation acc. to IEC A 1.Q12..-3A.5.-.... 1.Q12..-3A.7.-.... 355 M H HA EB HD T AA AB AC AQ B BA BB C H HA K K' L LM D 560 120 680 630 670 630 180 780 180 315 28 28 35 1525 1685 85 ● 560 120 680 630 670 630 180 780 200 315 28 28 35 1545 1705 95 560 120 680 630 670 835 180 985 180 315 28 28 35 1665 1825 85 DB E EB F GA M20 170 140 22 90 M24 170 140 25 100 M20 170 140 22 90 ● 560 120 680 630 670 835 180 985 200 315 28 28 35 1685 1845 95 M24 170 140 25 100 630 150 780 710 750 800 220 980 200 355 35 35 42 2115 2300 95 M24 170 140 25 100 ● 630 150 780 710 750 800 220 980 224 355 35 35 42 2180 2365 100 M24 210 180 28 106 ● Bearing design for increased cantilever forces, for type of construction IM B3 only. Siemens D 81.8 · 04/2014 5/33 © Siemens AG 2014 Forced-air cooled motors — enclosed version Dimensions Flanges G_D081_XX_00026 ■ Dimensional drawings (Z = the number of retaining holes) Flange with through holes Motor type 5 Frame size No. of poles Type of construction Flange type Dimension designation acc. to IEC LA 1LQ1/1MQ1 315 355 5/34 4, 6 4, 6 Siemens D 81.8 · 04/2014 IM B35, IM V1 IM B35, IM V1 LE M N P S T Z Flange 29 170 740 680 800 22 6 8 Flange (optional) 22 170 600 550 660 22 6 8 Flange 29 170 840 780 900 22 6 8 Flange (optional) 22 170 600 550 660 22 6 8 © Siemens AG 2014 Forced-air cooled motors — enclosed version Dimensions Terminal boxes ■ Dimensional drawings LL BE HB' HK HC AG1 IM B3 type of construction HD HB AG AD BC 5 G_D081_XX_00426 LL HC HB' HK HH AG1 IM B35 and IM V1 types of construction HD HB AG AD BE G_D081_XX_00427 Motor type Frame size No. of poles Terminal box Dimension designation acc. to IEC AD AG AG1 BC BE HB HB' HH HC HD HK LL 1LQ1/ 1MQ1 315 4, 6 1XB7 730 710 575 – 115 – 890 310 295 180 1025 255 345 1XB7 731 710 575 – 115 115 890 310 295 180 1025 255 345 1XB7 740 800 615 60 115 150 930 365 295 235 1110 340 425 GT640 655 555 – 115 110 870 225 295 155 970 170 310 1XB1 621 705 585 – 115 150 900 305 295 165 1020 250 330 1XB1 631 775 640 – 115 100 955 400 295 175 1090 320 555 1XB7 730 750 615 – 100 – 970 310 300 180 1105 255 345 1XB7 731 750 615 – 100 115 970 310 300 180 1105 255 345 1XB7 740 840 655 60 100 150 1010 365 300 235 1190 340 425 GT640 695 595 – 100 110 950 225 300 155 1050 170 310 1XB1 621 745 625 – 100 150 980 305 300 165 1100 250 330 1XB1 631 815 680 – 100 100 1035 400 300 175 1170 320 555 355 4, 6 Siemens D 81.8 · 04/2014 5/35 © Siemens AG 2014 Forced-air cooled motors — enclosed version Dimensions Notes 5 5/36 Siemens D 81.8 · 04/2014 6 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 6/2 6/2 6/2 6/4 6/6 6/6 6/8 6/10 6/10 6/12 6/14 6/14 6/16 6/18 6/18 6/20 6/22 1LH1/1MH1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency Premium Efficiency Line voltage 500 V, 50 Hz High Efficiency Premium Efficiency Line voltage 690 V, 50 Hz High Efficiency Premium Efficiency Line voltage 460 V, 60 Hz High Efficiency Premium Efficiency Line voltage 575 V, 60 Hz High Efficiency Premium Efficiency 6/22 6/22 6/24 6/26 6/26 6/28 6/30 6/30 6/32 1LH1/1MH1 motors for mains-fed operation Line voltage 400 V, 50 Hz High Efficiency Premium Efficiency Line voltage 690 V, 50 Hz High Efficiency Premium Efficiency Line voltage 460 V, 60 Hz High Efficiency Premium Efficiency 6/34 6/34 6/35 6/36 Dimensions 1LH1/1MH1 motors Flanges Terminal boxes Siemens D 81.8 · 04/2014 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency ■ Selection and ordering data 6 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LH1/1MH1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V 3000 rpm, 4-pole 330 443 315 Δ 100.9 1051 94.5 95.3 95.2 0.88 530 4.7 1.6 1■H1212-3AB11-1■■■ 1■H1212-3AB31-1■■■ 410 550 315 Δ 100.8 1306 95.0 95.7 95.6 0.89 650 5.1 1.7 460 617 315 Δ 100.8 1465 95.2 95.8 95.6 0.90 720 5.5 1.8 1■H1212-3AB51-1■■■ 535 717 315 Δ 100.8 1704 95.4 96.1 95.9 0.91 830 5.8 1.9 1■H1212-3AB71-1■■■ 1■H1212-3BB51-1■■■ 560 751 355 Δ 100.7 1783 95.3 95.9 95.6 0.89 890 5.3 1.9 575 771 355 Δ 100.7 1832 95.2 95.9 95.7 0.89 920 4.7 1.7 1■H1212-3BB71-1■■■ 1500 rpm, 4-pole 310 416 315 Δ 50.7 1974 94.0 95.2 95.7 0.88 500 5.7 2.1 1■H1212-3AB11-2■■■ 405 543 315 Δ 50.6 2579 94.6 95.7 96.0 0.89 650 6.4 2.3 1■H1212-3AB31-2■■■ 445 597 315 Δ 50.6 2834 94.6 95.7 96.0 0.90 700 6.6 2.3 1■H1212-3AB51-2■■■ 510 684 315 Δ 50.6 3248 94.7 95.8 96.1 0.90 800 6.5 2.3 1■H1212-3AB71-2■■■ 560 751 355 Δ 50.6 3566 94.9 96.0 96.4 0.89 890 5.7 2.2 1■H1212-3BB51-2■■■ 630 845 355 Δ 50.5 4012 95.2 96.2 96.5 0.89 1000 6.3 2.4 1■H1212-3BB71-2■■■ 1000 rpm, 6-pole 260 349 315 Δ 50.6 2483 94.1 95.2 95.6 0.81 460 6.2 2.0 1■H1212-3AC11-3■■■ 320 429 315 Δ 50.6 3058 94.3 95.4 95.8 0.83 550 6.3 2.0 1■H1212-3AC31-3■■■ 370 496 315 Δ 50.6 3534 94.4 95.5 95.9 0.84 630 6.1 1.9 1■H1212-3AC51-3■■■ 1■H1212-3AC71-3■■■ 415 557 315 Δ 50.6 3965 94.6 95.7 96.0 0.84 700 6.6 1.9 495 664 355 Δ 50.5 4729 94.5 95.6 95.8 0.86 820 7.0 2.1 1■H1212-3BC51-3■■■ 565 758 355 Δ 50.4 5398 94.8 95.8 95.9 0.86 930 7.8 1.8 1■H1212-3BC71-3■■■ 750 rpm, 6-pole 205 275 315 Δ 38.1 2611 92.9 94.3 94.8 0.81 365 6.1 2.0 1■H1212-3AC11-4■■■ 265 355 315 Δ 38.1 3377 93.1 94.5 95.1 0.83 460 5.9 1.9 1■H1212-3AC31-4■■■ 300 402 315 Δ 38.2 3821 93.1 94.5 95.2 0.84 510 5.5 1.8 1■H1212-3AC51-4■■■ 335 449 315 Δ 38.1 4267 93.2 94.7 95.3 0.85 570 5.5 1.7 1■H1212-3AC71-4■■■ 380 510 355 Δ 38 4839 93.3 94.6 95.1 0.87 630 6.3 2.0 1■H1212-3BC51-4■■■ 425 570 355 Δ 38 5412 93.5 94.8 95.3 0.87 700 6.5 1.8 1■H1212-3BC71-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V 3000 rpm, 4-pole 320 429 315 Δ 100.9 1020 94.5 95.3 95.1 0.88 580 4.7 1.6 1■H1222-3AB11-1■■■ 1■H1222-3AB31-1■■■ 410 550 315 Δ 100.8 1306 95.1 95.8 95.6 0.90 720 5.4 1.8 465 624 315 Δ 100.7 1481 95.3 95.9 95.7 0.90 820 5.9 2.0 1■H1222-3AB51-1■■■ 480 644 315 Δ 100.9 1529 95.1 95.8 95.7 0.90 850 5.0 1.7 1■H1222-3AB71-1■■■ 565 758 355 Δ 100.6 1799 95.5 96.0 95.6 0.89 1000 6.1 2.2 1■H1222-3BB51-1■■■ 585 784 355 Δ 100.6 1863 95.4 96.0 95.7 0.89 1040 5.4 2.0 1■H1222-3BB71-1■■■ 1500 rpm, 4-pole 320 429 315 Δ 50.6 2038 94.3 95.4 95.7 0.87 590 6.0 2.2 1■H1222-3AB11-2■■■ 400 536 315 Δ 50.6 2548 94.5 95.6 96.0 0.89 710 6.4 2.3 1■H1222-3AB31-2■■■ 450 603 315 Δ 50.6 2866 94.6 95.7 96.0 0.90 790 6.6 2.3 1■H1222-3AB51-2■■■ 520 697 315 Δ 50.6 3311 94.8 95.8 96.1 0.90 920 6.6 2.2 1■H1222-3AB71-2■■■ 565 758 355 Δ 50.6 3598 95.0 96.1 96.4 0.89 1000 6.0 2.3 1■H1222-3BB51-2■■■ 650 872 355 Δ 50.5 4139 95.3 96.3 96.5 0.89 1160 6.7 2.4 1■H1222-3BB71-2■■■ 1000 rpm, 6-pole 260 349 315 Δ 50.6 2483 94.0 95.1 95.5 0.82 510 6.0 1.9 1■H1222-3AC11-3■■■ 325 436 315 Δ 50.6 3105 94.3 95.4 95.8 0.83 620 6.3 2.0 1■H1222-3AC31-3■■■ 370 496 315 Δ 50.6 3536 94.5 95.6 95.9 0.84 700 6.4 2.0 1■H1222-3AC51-3■■■ 1■H1222-3AC71-3■■■ 420 563 315 Δ 50.6 4011 94.5 95.6 96.0 0.85 790 6.0 1.8 505 677 355 Δ 50.5 4825 94.7 95.7 95.8 0.86 930 7.6 2.1 1■H1222-3BC51-3■■■ 560 751 355 Δ 50.5 5351 94.8 95.8 95.9 0.87 1020 7.5 1.9 1■H1222-3BC71-3■■■ 750 rpm, 6-pole 220 295 315 Δ 38.2 2803 92.9 94.2 94.9 0.81 440 5.7 1.9 1■H1222-3AC11-4■■■ 270 362 315 Δ 38.1 3442 93.2 94.5 95.1 0.82 530 6.0 2.0 1■H1222-3AC31-4■■■ 305 409 315 Δ 38.1 3884 93.2 94.6 95.2 0.83 590 5.8 1.9 1■H1222-3AC51-4■■■ 330 443 315 Δ 38.1 4203 93.2 94.6 95.3 0.85 620 5.7 1.8 1■H1222-3AC71-4■■■ 380 510 355 Δ 38 4839 93.3 94.7 95.2 0.87 700 6.3 2.0 1■H1222-3BC51-4■■■ 430 577 355 Δ 38 5475 93.6 94.8 95.3 0.87 790 6.6 1.8 1■H1222-3BC71-4■■■ For versions, see Article No. supplements and special versions 1■H1222-3AC71-4■■■ Prated 6/2 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency Motor type mIM B3 mIM V1 J LpfA, LWA, Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 tolerance +3 dB(A) no-load Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.H1212-3AB11-1... 1.H1212-3AB31-1... 1.H1212-3AB51-1... 1.H1212-3AB71-1... 1.H1212-3BB51-1... 1.H1212-3BB71-1... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-0AA3 590 725 725 960 960 960 1.H1212-3AB11-2... 1.H1212-3AB31-2... 1.H1212-3AB51-2... 1.H1212-3AB71-2... 1.H1212-3BB51-2... 1.H1212-3BB71-2... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 590 725 725 820 960 1230 1.H1212-3AC11-3... 1.H1212-3AC31-3... 1.H1212-3AC51-3... 1.H1212-3AC71-3... 1.H1212-3BC51-3... 1.H1212-3BC71-3... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 477 590 725 725 820 960 1.H1212-3AC11-4... 1.H1212-3AC31-4... 1.H1212-3AC51-4... 1.H1212-3AC71-4... 1.H1212-3BC51-4... 1.H1212-3BC71-4... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LE33-8AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 370 477 590 590 725 725 1.H1222-3AB11-1... 1.H1222-3AB31-1... 1.H1222-3AB51-1... 1.H1222-3AB71-1... 1.H1222-3BB51-1... 1.H1222-3BB71-1... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-1AA3 590 725 820 960 1092 1092 1.H1222-3AB11-2... 1.H1222-3AB31-2... 1.H1222-3AB51-2... 1.H1222-3AB71-2... 1.H1222-3BB51-2... 1.H1222-3BB71-2... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-4AA3 590 725 820 960 1092 1340 1.H1222-3AC11-3... 1.H1222-3AC31-3... 1.H1222-3AC51-3... 1.H1222-3AC71-3... 1.H1222-3BC51-3... 1.H1222-3BC71-3... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 590 725 725 820 960 1092 1.H1222-3AC11-4... 1.H1222-3AC31-4... 1.H1222-3AC51-4... 1.H1222-3AC71-4... 1.H1222-3BC51-4... 1.H1222-3BC71-4... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 477 590 590 725 725 820 Siemens D 81.8 · 04/2014 6/3 6 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 400 V, 50 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LH1/1MH1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V 1500 rpm, 4-pole 225 302 315 Δ 50.5 1433 95.1 96.0 96.1 0.86 370 7.7 2.9 1■H1213-3AB11-2■■■ 365 489 315 Δ 50.6 2324 95.0 96.0 96.3 0.88 590 7.0 2.6 1■H1213-3AB31-2■■■ 400 536 315 Δ 50.6 2547 95.0 96.0 96.2 0.89 640 7.2 2.6 1■H1213-3AB51-2■■■ 480 644 315 Δ 50.6 3057 94.9 96.0 96.3 0.90 750 7.0 2.4 1■H1213-3AB71-2■■■ 570 764 355 Δ 50.6 3630 95.0 96.2 96.6 0.89 900 5.6 2.1 1■H1213-3BB51-2■■■ 645 865 355 Δ 50.6 4107 95.3 96.4 96.7 0.89 1020 6.2 2.3 1■H1213-3BB71-2■■■ 1000 rpm, 6-pole 6 210 282 315 Δ 50.5 2006 94.8 95.8 95.9 0.80 370 7.7 2.5 1■H1213-3AC11-3■■■ 290 389 315 Δ 50.5 2771 94.7 95.8 96.0 0.83 495 7.0 2.2 1■H1213-3AC31-3■■■ 335 449 315 Δ 50.5 3201 94.8 95.9 96.2 0.84 560 6.8 2.1 1■H1213-3AC51-3■■■ 410 550 315 Δ 50.6 3918 94.7 95.8 96.1 0.84 690 6.6 1.9 1■H1213-3AC71-3■■■ 510 684 355 Δ 50.5 4871 94.7 95.8 96.1 0.86 840 6.8 2.0 1■H1213-3BC51-3■■■ 580 778 355 Δ 50.5 5541 95.0 96.1 96.3 0.85 960 7.6 1.8 1■H1213-3BC71-3■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V 1500 rpm, 4-pole 245 329 315 Δ 50.5 1560 95.1 96.0 96.1 0.85 455 7.9 3.0 1■H1223-3AB11-2■■■ 360 483 315 Δ 50.6 2293 94.9 96.0 96.3 0.88 650 7.0 2.6 1■H1223-3AB31-2■■■ 405 543 315 Δ 50.6 2579 95.0 96.0 96.3 0.89 720 7.3 2.6 1■H1223-3AB51-2■■■ 495 664 315 Δ 50.6 3152 94.9 96.0 96.3 0.90 870 7.0 2.3 1■H1223-3AB71-2■■■ 580 778 355 Δ 50.6 3694 95.1 96.2 96.6 0.89 1020 5.8 2.2 1■H1223-3BB51-2■■■ 670 898 355 Δ 50.5 4266 95.4 96.5 96.8 0.88 1200 6.4 2.3 1■H1223-3BB71-2■■■ 1000 rpm, 6-pole 205 275 315 Δ 50.5 1959 94.8 95.8 95.9 0.81 400 7.6 2.4 1■H1223-3AC11-3■■■ 295 396 315 Δ 50.5 2819 94.7 95.8 96.0 0.82 570 6.9 2.2 1■H1223-3AC31-3■■■ 345 463 315 Δ 50.5 3296 94.7 95.8 96.1 0.83 660 6.8 2.1 1■H1223-3AC51-3■■■ 405 543 315 Δ 50.6 3870 94.6 95.8 96.1 0.84 760 6.3 1.9 1■H1223-3AC71-3■■■ 515 691 355 Δ 50.5 4921 94.9 95.9 96.2 0.85 960 7.3 2.0 1■H1223-3BC51-3■■■ 575 771 355 Δ 50.5 5494 94.9 96.0 96.3 0.86 1060 7.2 1.8 1■H1223-3BC71-3■■■ For versions, see Article No. supplements and special versions 6/4 Siemens D 81.8 · 04/2014 1■H1223-3AC71-3■■■ © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 400 V, 50 Hz Premium Efficiency Motor type mIM B3 mIM V1 J Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.H1213-3AB11-2... 1240 1290 3.5 78 93 3000 1XB7 731 6SL3710-7LE33-8AA3 370 1.H1213-3AB31-2... 1420 1470 4.4 78 93 3000 1XB7 731 6SL3710-7LE36-1AA3 590 1.H1213-3AB51-2... 1600 1650 5.0 78 93 3000 1XB7 740 6SL3710-7LE37-5AA3 725 1.H1213-3AB71-2... 1770 1820 5.8 78 93 3000 1XB7 740 6SL3710-7LE38-4AA3 820 1.H1213-3BB51-2... 2200 2250 8.3 78 93.5 2600 1XB7 740 6SL3710-7LE41-0AA3 960 1.H1213-3BB71-2... 2320 2380 8.9 78 93.5 2600 1XB7 740 6SL3710-7LE41-2AA3 1230 1.H1213-3AC11-3... 1270 1320 5.9 78 93 2600 1XB7 731 6SL3710-7LE33-8AA3 370 1.H1213-3AC31-3... 1450 1500 7.2 78 93 2600 1XB7 731 6SL3710-7LE36-1AA3 590 1.H1213-3AC51-3... 1630 1680 8.3 78 93 2600 1XB7 731 6SL3710-7LE36-1AA3 590 1.H1213-3AC71-3... 1740 1790 9.1 78 93 2600 1XB7 740 6SL3710-7LE37-5AA3 725 1.H1213-3BC51-3... 2190 2250 14.5 78 93.5 2500 1XB7 740 6SL3710-7LE41-0AA3 960 1.H1213-3BC71-3... 2340 2390 16.0 78 93.5 2500 1XB7 740 6SL3710-7LE41-0AA3 960 1.H1223-3AB11-2... 1240 1290 3.5 78 93 3000 1XB7 731 6SL3710-1GE35-0AA3 477 1.H1223-3AB31-2... 1420 1470 4.4 78 93 3000 1XB7 740 6SL3710-1GE37-5AA3 725 1.H1223-3AB51-2... 1600 1650 5.0 78 93 3000 1XB7 740 6SL3710-1GE37-5AA3 725 1.H1223-3AB71-2... 1770 1820 5.8 78 93 3000 1XB7 740 6SL3710-1GE41-0AA3 960 1.H1223-3BB51-2... 2200 2250 8.3 78 93.5 2600 1XB7 740 6SL3710-2GE41-1AA3 1092 1.H1223-3BB71-2... 2320 2380 8.9 78 93.5 2600 2 x 1XB7 740 6SL3710-2GE41-4AA3 1340 1.H1223-3AC11-3... 1270 1320 5.9 78 93 2600 1XB7 731 6SL3710-1GE35-0AA3 477 1.H1223-3AC31-3... 1450 1500 7.2 78 93 2600 1XB7 731 6SL3710-1GE36-1AA3 590 1.H1223-3AC51-3... 1630 1680 8.3 78 93 2600 1XB7 740 6SL3710-1GE37-5AA3 725 1.H1223-3AC71-3... 1740 1790 9.1 78 93 2600 1XB7 740 6SL3710-1GE38-4AA3 820 1.H1223-3BC51-3... 2190 2250 14.5 78 93.5 2500 1XB7 740 6SL3710-1GE41-0AA3 1.H1223-3BC71-3... 2340 2390 16.0 78 93.5 2500 2 x 1XB7 740 6SL3710-2GE41-1AA3 Siemens D 81.8 · 04/2014 6 960 1092 6/5 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency ■ Selection and ordering data 6 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LH1/1MH1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V 3000 rpm, 4-pole 305 409 315 Δ 100.8 971 94.6 95.2 95.0 0.89 400 5.3 1.8 1■H1212-3AB12-1■■■ 1■H1212-3AB32-1■■■ 405 543 315 Δ 100.7 1290 95.2 95.8 95.6 0.90 520 6.3 2.1 450 603 315 Δ 100.7 1433 95.3 95.8 95.6 0.90 580 6.5 2.1 1■H1212-3AB52-1■■■ 470 630 315 Δ 100.8 1497 95.1 95.8 95.6 0.90 610 5.4 1.8 1■H1212-3AB72-1■■■ 1■H1212-3BB52-1■■■ 545 731 355 Δ 100.6 1736 95.3 95.9 95.5 0.89 710 5.9 2.1 570 764 355 Δ 100.7 1815 95.2 95.9 95.6 0.89 740 5.3 1.9 1■H1212-3BB72-1■■■ 1500 rpm, 4-pole 285 382 315 Δ 50.7 1815 94.0 95.2 95.6 0.88 380 6.0 2.2 1■H1212-3AB12-2■■■ 360 483 315 Δ 50.6 2293 94.3 95.5 95.9 0.89 470 6.4 2.3 1■H1212-3AB32-2■■■ 420 563 315 Δ 50.6 2675 94.6 95.6 95.9 0.90 540 7.1 2.5 1■H1212-3AB52-2■■■ 505 677 315 Δ 50.5 3215 95.0 95.9 96.1 0.89 660 7.7 2.3 1■H1212-3AB72-2■■■ 560 751 355 Δ 50.5 3566 95.1 96.1 96.3 0.88 740 6.7 2.6 1■H1212-3BB52-2■■■ 620 831 355 Δ 50.5 3948 95.3 96.3 96.4 0.88 810 7.3 2.5 1■H1212-3BB72-2■■■ 1000 rpm, 6-pole 250 335 315 Δ 50.6 2389 94.0 95.2 95.5 0.82 355 6.5 2.1 1■H1212-3AC12-3■■■ 300 402 315 Δ 50.6 2867 94.2 95.3 95.6 0.83 420 6.7 2.1 1■H1212-3AC32-3■■■ 335 449 315 Δ 50.6 3202 94.2 95.4 95.7 0.84 465 6.4 2.0 1■H1212-3AC52-3■■■ 1■H1212-3AC72-3■■■ 375 503 315 Δ 50.6 3584 94.4 95.5 95.8 0.85 510 6.6 2.0 460 617 355 Δ 50.4 4396 94.5 95.5 95.7 0.86 620 7.7 2.3 1■H1212-3BC52-3■■■ 515 691 355 Δ 50.4 4920 94.7 95.7 95.7 0.86 690 8.2 2.0 1■H1212-3BC72-3■■■ 750 rpm, 6-pole 200 268 315 Δ 38.1 2547 92.7 94.1 94.6 0.80 295 6.2 2.1 1■H1212-3AC12-4■■■ 245 329 315 Δ 38.1 3120 93.0 94.4 94.9 0.82 350 6.3 2.1 1■H1212-3AC32-4■■■ 270 362 315 Δ 38.1 3440 92.9 94.3 95.0 0.84 380 5.8 1.9 1■H1212-3AC52-4■■■ 310 416 315 Δ 38.1 3949 93.1 94.5 95.1 0.84 435 6.0 1.9 1■H1212-3AC72-4■■■ 365 489 355 Δ 37.9 4650 93.5 94.7 95.1 0.86 500 7.2 2.1 1■H1212-3BC52-4■■■ 390 523 355 Δ 38 4967 93.4 94.7 95.1 0.87 530 6.8 2.0 1■H1212-3BC72-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V 3000 rpm, 4-pole 330 443 315 Δ 100.8 1051 94.7 95.4 95.2 0.88 475 4.9 1.7 1■H1222-3AB12-1■■■ 1■H1222-3AB32-1■■■ 415 557 315 Δ 100.8 1322 95.0 95.7 95.6 0.89 590 5.1 1.7 460 617 315 Δ 100.8 1465 95.1 95.8 95.6 0.90 640 5.4 1.8 1■H1222-3AB52-1■■■ 520 697 315 Δ 100.8 1656 95.3 96.0 95.8 0.91 720 5.6 1.8 1■H1222-3AB72-1■■■ 545 731 355 Δ 100.7 1736 95.2 95.9 95.6 0.89 770 5.0 1.8 1■H1222-3BB52-1■■■ 615 825 355 Δ 100.6 1958 95.5 96.1 95.8 0.89 860 5.8 2.1 1■H1222-3BB72-1■■■ 1500 rpm, 4-pole 305 409 315 Δ 50.7 1942 93.9 95.2 95.6 0.88 440 5.5 2.0 1■H1222-3AB12-2■■■ 415 557 315 Δ 50.6 2643 94.6 95.7 96.0 0.88 590 6.6 2.4 1■H1222-3AB32-2■■■ 455 610 315 Δ 50.6 2897 94.7 95.7 96.0 0.90 640 6.6 2.4 1■H1222-3AB52-2■■■ 510 684 315 Δ 50.6 3248 94.7 95.8 96.1 0.90 710 6.6 2.3 1■H1222-3AB72-2■■■ 615 825 355 Δ 50.5 3916 95.3 96.3 96.4 0.88 870 6.7 2.5 1■H1222-3BB52-2■■■ 630 845 355 Δ 50.6 4012 95.2 96.2 96.5 0.89 890 6.1 2.3 1■H1222-3BB72-2■■■ 1000 rpm, 6-pole 255 342 315 Δ 50.7 2436 93.8 95.1 95.5 0.82 395 5.7 1.8 1■H1222-3AC12-3■■■ 330 443 315 Δ 50.6 3153 94.3 95.4 95.8 0.83 500 6.4 2.0 1■H1222-3AC32-3■■■ 370 496 315 Δ 50.6 3534 94.4 95.5 95.9 0.84 550 6.2 1.9 1■H1222-3AC52-3■■■ 1■H1222-3AC72-3■■■ 415 557 315 Δ 50.6 3965 94.6 95.7 96.0 0.84 620 6.4 1.9 495 664 355 Δ 50.5 4730 94.5 95.5 95.8 0.86 720 6.9 2.1 1■H1222-3BC52-3■■■ 560 751 355 Δ 50.5 5351 94.7 95.7 95.9 0.87 810 7.4 1.9 1■H1222-3BC72-3■■■ 750 rpm, 6-pole 215 288 315 Δ 38.2 2740 92.6 94.1 94.8 0.81 340 5.6 1.9 1■H1222-3AC12-4■■■ 265 355 315 Δ 38.1 3374 93.1 94.4 95.0 0.83 405 5.9 1.9 1■H1222-3AC32-4■■■ 295 396 315 Δ 38.2 3757 92.9 94.4 95.1 0.84 445 5.4 1.8 1■H1222-3AC52-4■■■ 315 422 315 Δ 38.1 4012 93.1 94.6 95.2 0.85 470 5.6 1.8 1■H1222-3AC72-4■■■ 390 523 355 Δ 38 4966 93.4 94.7 95.2 0.87 570 6.4 2.0 1■H1222-3BC52-4■■■ 430 577 355 Δ 38 5476 93.5 94.8 95.3 0.87 630 6.5 1.8 1■H1222-3BC72-4■■■ For versions, see Article No. supplements and special versions 1■H1222-3AC72-4■■■ Prated 6/6 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.H1212-3AB12-1... 1.H1212-3AB32-1... 1.H1212-3AB52-1... 1.H1212-3AB72-1... 1.H1212-3BB52-1... 1.H1212-3BB72-1... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 400 560 710 710 710 790 1.H1212-3AB12-2... 1.H1212-3AB32-2... 1.H1212-3AB52-2... 1.H1212-3AB72-2... 1.H1212-3BB52-2... 1.H1212-3BB72-2... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 6SL3710-7LG38-8AA3 400 560 560 710 790 880 1.H1212-3AC12-3... 1.H1212-3AC32-3... 1.H1212-3AC52-3... 1.H1212-3AC72-3... 1.H1212-3BC52-3... 1.H1212-3BC72-3... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 400 452 560 560 710 710 1.H1212-3AC12-4... 1.H1212-3AC32-4... 1.H1212-3AC52-4... 1.H1212-3AC72-4... 1.H1212-3BC52-4... 1.H1212-3BC72-4... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 320 400 400 452 560 560 1.H1222-3AB12-1... 1.H1222-3AB32-1... 1.H1222-3AB52-1... 1.H1222-3AB72-1... 1.H1222-3BB52-1... 1.H1222-3BB72-1... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 477 590 725 725 820 960 1.H1222-3AB12-2... 1.H1222-3AB32-2... 1.H1222-3AB52-2... 1.H1222-3AB72-2... 1.H1222-3BB52-2... 1.H1222-3BB72-2... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE41-0AA3 6SL3710-1GE41-0AA3 477 590 725 725 960 960 1.H1222-3AC12-3... 1.H1222-3AC32-3... 1.H1222-3AC52-3... 1.H1222-3AC72-3... 1.H1222-3BC52-3... 1.H1222-3BC72-3... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 477 590 590 725 725 820 1.H1222-3AC12-4... 1.H1222-3AC32-4... 1.H1222-3AC52-4... 1.H1222-3AC72-4... 1.H1222-3BC52-4... 1.H1222-3BC72-4... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 370 477 477 477 590 725 Siemens D 81.8 · 04/2014 6 6/7 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 500 V, 50 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LH1/1MH1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V 1500 rpm, 4-pole 210 282 315 Δ 50.5 1337 94.9 96.0 95.9 0.86 280 8.2 3.0 1■H1213-3AB12-2■■■ 290 389 315 Δ 50.5 1846 95.0 96.0 96.2 0.88 380 7.8 2.8 1■H1213-3AB32-2■■■ 365 489 315 Δ 50.5 2324 95.0 96.0 96.2 0.89 475 8.0 2.8 1■H1213-3AB52-2■■■ 505 677 315 Δ 50.5 3215 95.0 96.0 96.2 0.89 660 7.7 2.3 1■H1213-3AB72-2■■■ 575 771 355 Δ 50.5 3662 95.2 96.3 96.6 0.88 750 6.6 2.5 1■H1213-3BB52-2■■■ 640 858 355 Δ 50.5 4075 95.4 96.5 96.7 0.88 840 7.1 2.4 1■H1213-3BB72-2■■■ 1000 rpm, 6-pole 6 195 261 315 Δ 50.4 1863 94.7 95.7 95.8 0.80 285 8.1 2.7 1■H1213-3AC12-3■■■ 260 349 315 Δ 50.5 2484 94.7 95.8 95.9 0.82 365 7.7 2.4 1■H1213-3AC32-3■■■ 300 402 315 Δ 50.5 2867 94.7 95.8 96.0 0.84 415 7.1 2.2 1■H1213-3AC52-3■■■ 340 456 315 Δ 50.5 3248 94.8 95.8 96.1 0.84 470 7.1 2.2 1■H1213-3AC72-3■■■ 470 630 355 Δ 50.5 4491 94.7 95.8 96.1 0.86 630 7.5 2.2 1■H1213-3BC52-3■■■ 530 711 355 Δ 50.4 5064 94.9 95.9 96.1 0.86 710 7.9 2.0 1■H1213-3BC72-3■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V 1500 rpm, 4-pole 220 295 315 Δ 50.5 1401 94.9 96.0 96.0 0.87 315 7.6 2.8 1■H1223-3AB12-2■■■ 370 496 315 Δ 50.5 2356 95.1 96.0 96.3 0.88 530 7.3 2.7 1■H1223-3AB32-2■■■ 410 550 315 Δ 50.6 2611 95.1 96.0 96.3 0.89 580 7.3 2.6 1■H1223-3AB52-2■■■ 470 630 315 Δ 50.6 2993 94.9 96.0 96.3 0.90 650 7.2 2.5 1■H1223-3AB72-2■■■ 630 845 355 Δ 50.5 4012 95.4 96.4 96.7 0.88 890 6.6 2.5 1■H1223-3BB52-2■■■ 645 865 355 Δ 50.6 4108 95.2 96.3 96.7 0.89 910 6.0 2.3 1■H1223-3BB72-2■■■ 1000 rpm, 6-pole 195 261 315 Δ 50.5 1863 94.8 95.8 95.9 0.81 300 7.6 2.4 1■H1223-3AC12-3■■■ 295 396 315 Δ 50.5 2819 94.7 95.8 96.0 0.82 450 7.1 2.2 1■H1223-3AC32-3■■■ 335 449 315 Δ 50.5 3201 94.8 95.9 96.1 0.84 500 6.8 2.1 1■H1223-3AC52-3■■■ 405 543 315 Δ 50.6 3870 94.7 95.8 96.1 0.84 610 6.5 1.9 1■H1223-3AC72-3■■■ 505 677 355 Δ 50.5 4823 94.6 95.8 96.1 0.86 740 6.7 2.1 1■H1223-3BC52-3■■■ 575 771 355 Δ 50.5 5495 94.9 96.0 96.2 0.86 840 7.1 1.8 1■H1223-3BC72-3■■■ For versions, see Article No. supplements and special versions 6/8 Siemens D 81.8 · 04/2014 1■H1223-3AC72-3■■■ © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 500 V, 50 Hz Premium Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.H1213-3AB12-2... 1240 1290 3.5 78 93 3000 1XB7 730 6SL3710-7LG33-3AA3 320 1.H1213-3AB32-2... 1420 1470 4.4 78 93 3000 1XB7 731 6SL3710-7LG34-1AA3 400 1.H1213-3AB52-2... 1600 1650 5.0 78 93 3000 1XB7 731 6SL3710-7LG35-8AA3 560 1.H1213-3AB72-2... 1770 1820 5.8 78 93 3000 1XB7 740 6SL3710-7LG37-4AA3 710 1.H1213-3BB52-2... 2200 2250 8.3 78 93.5 2600 1XB7 740 6SL3710-7LG38-1AA3 790 1.H1213-3BB72-2... 2320 2380 8.9 78 93.5 2600 1XB7 740 6SL3710-7LG38-8AA3 880 1.H1213-3AC12-3... 1270 1320 5.9 78 93 2600 1XB7 730 6SL3710-7LG33-3AA3 320 1.H1213-3AC32-3... 1450 1500 7.2 78 93 2600 1XB7 731 6SL3710-7LG34-1AA3 400 1.H1213-3AC52-3... 1630 1680 8.3 78 93 2600 1XB7 731 6SL3710-7LG34-7AA3 452 1.H1213-3AC72-3... 1740 1790 9.1 78 93 2600 1XB7 731 6SL3710-7LG35-8AA3 560 1.H1213-3BC52-3... 2190 2250 14.5 78 93.5 2500 1XB7 740 6SL3710-7LG37-4AA3 710 1.H1213-3BC72-3... 2340 2390 16.0 78 93.5 2500 1XB7 740 6SL3710-7LG37-4AA3 710 1.H1223-3AB12-2... 1240 1290 3.5 78 93 3000 1XB7 730 6SL3710-1GE33-8AA3 370 1.H1223-3AB32-2... 1420 1470 4.4 78 93 3000 1XB7 731 6SL3710-1GE36-1AA3 590 1.H1223-3AB52-2... 1600 1650 5.0 78 93 3000 1XB7 731 6SL3710-1GE36-1AA3 590 1.H1223-3AB72-2... 1770 1820 5.8 78 93 3000 1XB7 740 6SL3710-1GE37-5AA3 725 1.H1223-3BB52-2... 2200 2250 8.3 78 93.5 2600 1XB7 740 6SL3710-1GE41-0AA3 960 1.H1223-3BB72-2... 2320 2380 8.9 78 93.5 2600 1XB7 740 6SL3710-1GE41-0AA3 960 1.H1223-3AC12-3... 1270 1320 5.9 78 93 2600 1XB7 730 6SL3710-1GE33-1AA3 302 1.H1223-3AC32-3... 1450 1500 7.2 78 93 2600 1XB7 731 6SL3710-1GE35-0AA3 477 1.H1223-3AC52-3... 1630 1680 8.3 78 93 2600 1XB7 731 6SL3710-1GE36-1AA3 590 1.H1223-3AC72-3... 1740 1790 9.1 78 93 2600 1XB7 740 6SL3710-1GE37-5AA3 725 1.H1223-3BC52-3... 2190 2250 14.5 78 93.5 2500 1XB7 740 6SL3710-1GE38-4AA3 820 1.H1223-3BC72-3... 2340 2390 16.0 78 93.5 2500 1XB7 740 6SL3710-1GE41-0AA3 960 Siemens D 81.8 · 04/2014 6 6/9 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency ■ Selection and ordering data 6 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LH1/1MH1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V 3000 rpm, 4-pole 310 416 315 Δ 100.8 987 94.5 95.2 95.0 0.88 295 5.0 1.7 1■H1212-3AB13-1■■■ 1■H1212-3AB33-1■■■ 405 543 315 Δ 100.7 1290 95.1 95.7 95.5 0.90 370 5.9 2.0 465 624 315 Δ 100.7 1480 95.3 95.9 95.6 0.90 425 6.6 2.2 1■H1212-3AB53-1■■■ 520 697 315 Δ 100.7 1656 95.4 96.0 95.8 0.91 470 6.4 2.1 1■H1212-3AB73-1■■■ 1■H1212-3BB53-1■■■ 560 751 355 Δ 100.6 1783 95.3 95.9 95.6 0.89 520 5.6 2.0 580 778 355 Δ 100.7 1847 95.2 95.9 95.6 0.89 540 5.0 1.8 1■H1212-3BB73-1■■■ 1500 rpm, 4-pole 290 389 315 Δ 50.6 1847 94.0 95.2 95.6 0.88 275 6.2 2.2 1■H1212-3AB13-2■■■ 375 503 315 Δ 50.6 2388 94.5 95.6 95.9 0.88 355 6.9 2.5 1■H1212-3AB33-2■■■ 430 577 315 Δ 50.6 2738 94.7 95.7 96.0 0.89 400 7.2 2.6 1■H1212-3AB53-2■■■ 490 657 315 Δ 50.5 3120 94.9 95.8 96.1 0.90 450 7.6 2.4 1■H1212-3AB73-2■■■ 555 744 355 Δ 50.5 3534 95.1 96.1 96.3 0.89 510 6.5 2.5 1■H1212-3BB53-2■■■ 600 805 355 Δ 50.5 3821 95.1 96.2 96.4 0.89 550 6.7 2.5 1■H1212-3BB73-2■■■ 1000 rpm, 6-pole 240 322 315 Y 50.6 2294 93.9 95.1 95.4 0.82 245 6.6 2.1 1■H1212-3AC13-3■■■ 295 396 315 Y 50.6 2819 94.2 95.3 95.6 0.83 295 6.7 2.1 1■H1212-3AC33-3■■■ 340 456 315 Y 50.6 3250 94.3 95.4 95.7 0.84 335 6.5 2.0 1■H1212-3AC53-3■■■ 1■H1212-3AC73-3■■■ 385 516 315 Δ 50.6 3679 94.4 95.6 95.9 0.85 375 6.6 2.0 455 610 355 Δ 50.4 4348 94.5 95.5 95.7 0.86 440 7.6 2.3 1■H1212-3BC53-3■■■ 520 697 355 Δ 50.4 4968 94.7 95.7 95.7 0.86 500 8.1 2.0 1■H1212-3BC73-3■■■ 750 rpm, 6-pole 195 261 315 Y 38.1 2483 92.6 94.0 94.6 0.81 205 6.1 2.1 1■H1212-3AC13-4■■■ 250 335 315 Y 38.1 3186 93.0 94.4 95.0 0.83 250 6.2 2.0 1■H1212-3AC33-4■■■ 275 369 315 Δ 38.1 3505 93.0 94.4 95.0 0.84 275 5.9 1.9 1■H1212-3AC53-4■■■ 310 416 315 Δ 38.1 3948 93.1 94.5 95.2 0.85 305 5.8 1.9 1■H1212-3AC73-4■■■ 360 483 355 Y 37.9 4586 93.5 94.7 95.1 0.86 350 7.2 2.2 1■H1212-3BC53-4■■■ 410 550 355 Δ 37.9 5223 93.6 94.8 95.2 0.87 395 7.3 1.9 1■H1212-3BC73-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V 3000 rpm, 4-pole 310 416 315 Δ 100.8 987 94.6 95.3 95.0 0.89 320 5.4 1.8 1■H1222-3AB13-1■■■ 1■H1222-3AB33-1■■■ 390 523 315 Δ 100.7 1242 95.1 95.7 95.5 0.90 395 5.9 1.9 445 597 315 Δ 100.6 1417 95.3 95.9 95.5 0.90 450 6.8 2.2 1■H1222-3AB53-1■■■ 510 684 315 Δ 100.7 1624 95.4 96.0 95.8 0.91 510 6.6 2.2 1■H1222-3AB73-1■■■ 540 724 355 Δ 100.6 1720 95.3 95.9 95.5 0.89 550 5.9 2.1 1■H1222-3BB53-1■■■ 550 738 355 Δ 100.7 1751 95.2 95.9 95.6 0.89 560 5.4 1.9 1■H1222-3BB73-1■■■ 1500 rpm, 4-pole 295 396 315 Δ 50.7 1879 94.1 95.2 95.6 0.88 310 6.1 2.2 1■H1222-3AB13-2■■■ 370 496 315 Δ 50.6 2356 94.4 95.5 95.9 0.89 380 6.5 2.3 1■H1222-3AB33-2■■■ 410 550 315 Δ 50.6 2611 94.6 95.6 95.9 0.90 415 7.1 2.5 1■H1222-3AB53-2■■■ 490 657 315 Δ 50.6 3120 94.8 95.8 96.1 0.90 495 7.4 2.4 1■H1222-3AB73-2■■■ 565 758 355 Δ 50.5 3598 95.3 96.2 96.4 0.88 580 7.3 2.8 1■H1222-3BB53-2■■■ 585 784 355 Δ 50.5 3725 95.1 96.2 96.4 0.89 600 6.6 2.5 1■H1222-3BB73-2■■■ 1000 rpm, 6-pole 240 322 315 Y 50.6 2294 93.9 95.0 95.4 0.82 270 6.5 2.1 1■H1222-3AC13-3■■■ 290 389 315 Δ 50.5 2771 94.3 95.4 95.6 0.83 320 6.9 2.2 1■H1222-3AC33-3■■■ 345 463 315 Δ 50.6 3297 94.3 95.5 95.8 0.84 375 6.5 2.0 1■H1222-3AC53-3■■■ 1■H1222-3AC73-3■■■ 380 510 315 Δ 50.5 3631 94.5 95.6 95.8 0.84 415 6.9 2.0 450 603 355 Δ 50.4 4301 94.5 95.5 95.7 0.86 480 7.5 2.3 1■H1222-3BC53-3■■■ 510 684 355 Δ 50.4 4873 94.7 95.7 95.7 0.86 540 8.3 2.0 1■H1222-3BC73-3■■■ 750 rpm, 6-pole 180 241 315 Y 38.1 2294 92.8 94.1 94.7 0.81 205 6.4 2.1 1■H1222-3AC13-4■■■ 255 342 315 Δ 38.1 3250 93.1 94.5 95.0 0.82 290 6.3 2.1 1■H1222-3AC33-4■■■ 280 375 315 Δ 38.1 3568 93.1 94.5 95.1 0.84 310 6.0 2.0 1■H1222-3AC53-4■■■ 295 396 315 Δ 38.1 3760 93.1 94.5 95.1 0.85 320 6.0 2.0 1■H1222-3AC73-4■■■ 365 489 355 Δ 37.9 4650 93.5 94.7 95.1 0.86 390 7.3 2.1 1■H1222-3BC53-4■■■ 395 530 355 Δ 38 5031 93.5 94.7 95.1 0.87 420 7.1 2.0 1■H1222-3BC73-4■■■ For versions, see Article No. supplements and special versions 1■H1222-3AC73-4■■■ Prated 6/10 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.H1212-3AB13-1... 1.H1212-3AB33-1... 1.H1212-3AB53-1... 1.H1212-3AB73-1... 1.H1212-3BB53-1... 1.H1212-3BB73-1... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 320 400 452 560 560 560 1.H1212-3AB13-2... 1.H1212-3AB33-2... 1.H1212-3AB53-2... 1.H1212-3AB73-2... 1.H1212-3BB53-2... 1.H1212-3BB73-2... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 320 400 400 452 560 560 1.H1212-3AC13-3... 1.H1212-3AC33-3... 1.H1212-3AC53-3... 1.H1212-3AC73-3... 1.H1212-3BC53-3... 1.H1212-3BC73-3... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 250 320 400 400 452 560 1.H1212-3AC13-4... 1.H1212-3AC33-4... 1.H1212-3AC53-4... 1.H1212-3AC73-4... 1.H1212-3BC53-4... 1.H1212-3BC73-4... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 6SL3710-7LG32-2AA3 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 208 250 320 320 400 400 1.H1222-3AB13-1... 1.H1222-3AB33-1... 1.H1222-3AB53-1... 1.H1222-3AB73-1... 1.H1222-3BB53-1... 1.H1222-3BB73-1... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH35-8AA3 6SL3710-1GH35-8AA3 320 400 452 560 560 560 1.H1222-3AB13-2... 1.H1222-3AB33-2... 1.H1222-3AB53-2... 1.H1222-3AB73-2... 1.H1222-3BB53-2... 1.H1222-3BB73-2... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH37-4AA3 6SL3710-1GH37-4AA3 320 400 452 560 710 710 1.H1222-3AC13-3... 1.H1222-3AC33-3... 1.H1222-3AC53-3... 1.H1222-3AC73-3... 1.H1222-3BC53-3... 1.H1222-3BC73-3... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH35-8AA3 320 320 400 452 560 560 1.H1222-3AC13-4... 1.H1222-3AC33-4... 1.H1222-3AC53-4... 1.H1222-3AC73-4... 1.H1222-3BC53-4... 1.H1222-3BC73-4... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-1GH32-2AA3 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 208 320 320 320 400 452 Siemens D 81.8 · 04/2014 6 6/11 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 690 V, 50 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LH1/1MH1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V 1500 rpm, 4-pole 210 282 315 Δ 50.4 1337 94.9 96.0 95.9 0.85 205 8.3 3.1 1■H1213-3AB13-2■■■ 330 443 315 Δ 50.5 2101 95.0 96.0 96.2 0.87 310 7.9 2.9 1■H1213-3AB33-2■■■ 385 516 315 Δ 50.5 2451 95.0 96.0 96.2 0.88 360 8.0 2.9 1■H1213-3AB53-2■■■ 445 630 315 Δ 50.5 2992 95.0 96.0 96.2 0.89 435 7.8 2.5 1■H1213-3AB73-2■■■ 570 764 355 Δ 50.5 3630 95.1 96.3 96.6 0.88 530 6.3 2.4 1■H1213-3BB53-2■■■ 330 818 355 Δ 50.5 3885 95.3 96.3 96.6 0.89 560 6.6 2.5 1■H1213-3BB73-2■■■ 1000 rpm, 6-pole 6 185 248 315 Y 50.4 1767 94.8 95.7 95.7 0.79 194 8.3 2.7 1■H1213-3AC13-3■■■ 250 335 315 Y 50.5 2389 94.8 95.8 95.9 0.82 250 7.9 2.5 1■H1213-3AC33-3■■■ 310 416 315 Y 50.5 2962 94.7 95.8 96.0 0.84 305 7.1 2.2 1■H1213-3AC53-3■■■ 350 476 315 Δ 50.5 3392 94.7 95.8 96.1 0.84 350 7.0 2.2 1■H1213-3AC73-3■■■ 465 624 355 Δ 50.5 4443 94.6 95.8 96.0 0.86 445 7.5 2.2 1■H1213-3BC53-3■■■ 250 717 355 Δ 50.4 5112 94.9 95.9 96.1 0.86 510 7.9 1.9 1■H1213-3BC73-3■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V 1500 rpm, 4-pole 215 288 315 Δ 50.5 1369 94.9 96.0 95.9 0.85 230 8.1 3.0 1■H1223-3AB13-2■■■ 310 416 315 Δ 50.5 1974 95.0 96.0 96.2 0.88 320 7.8 2.8 1■H1223-3AB33-2■■■ 360 483 315 Δ 50.5 2292 95.0 96.0 96.1 0.89 370 8.0 2.9 1■H1223-3AB53-2■■■ 445 597 315 Δ 50.5 2833 95.0 96.0 96.2 0.90 450 8.0 2.6 1■H1223-3AB73-2■■■ 580 778 355 Δ 50.5 3693 95.4 96.4 96.6 0.87 600 7.1 2.7 1■H1223-3BB53-2■■■ 600 805 355 Δ 50.5 3821 95.2 96.3 96.6 0.89 610 6.5 2.4 1■H1223-3BB73-2■■■ 1000 rpm, 6-pole 175 235 315 Y 50.4 1672 94.9 95.7 95.7 0.79 200 8.8 2.8 1■H1223-3AC13-3■■■ 255 342 315 Δ 50.5 2436 94.8 95.8 95.9 0.82 285 7.8 2.5 1■H1223-3AC33-3■■■ 315 422 315 Δ 50.5 3010 94.7 95.8 96.1 0.84 340 7.2 2.2 1■H1223-3AC53-3■■■ 360 483 315 Δ 50.5 3440 94.7 95.8 96.0 0.84 390 7.3 2.2 1■H1223-3AC73-3■■■ 460 617 355 Δ 50.5 4395 94.6 95.8 96.1 0.86 490 7.3 2.3 1■H1223-3BC53-3■■■ 525 704 355 Δ 50.4 5016 94.9 96.0 96.2 0.86 560 7.9 2.0 1■H1223-3BC73-3■■■ For versions, see Article No. supplements and special versions 6/12 Siemens D 81.8 · 04/2014 1■H1223-3AC73-3■■■ © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 690 V, 50 Hz Premium Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.H1213-3AB13-2... 1240 1290 3.5 78 93 3000 1XB7 730 6SL3710-7LG32-6AA3 208 1.H1213-3AB33-2... 1420 1470 4.4 78 93 3000 1XB7 730 6SL3710-7LG33-3AA3 320 1.H1213-3AB53-2... 1600 1650 5.0 78 93 3000 1XB7 731 6SL3710-7LG34-1AA3 400 1.H1213-3AB73-2... 1770 1820 5.8 78 93 3000 1XB7 731 6SL3710-7LG34-7AA3 452 1.H1213-3BB53-2... 2200 2250 8.3 78 93.5 2600 1XB7 731 6SL3710-7LG32-6AA3 560 1.H1213-3BB73-2... 2320 2380 8.9 78 93.5 2600 1XB7 731 6SL3710-7LG33-3AA3 560 1.H1213-3AC13-3... 1270 1320 5.9 78 93 2600 1XB7 730 6SL3710-7LG32-2AA3 208 1.H1213-3AC33-3... 1450 1500 7.2 78 93 2600 1XB7 730 6SL3710-7LG32-6AA3 250 1.H1213-3AC53-3... 1630 1680 8.3 78 93 2600 1XB7 730 6SL3710-7LG33-3AA3 320 1.H1213-3AC73-3... 1740 1790 9.1 78 93 2600 1XB7 730 6SL3710-7LG34-1AA3 400 1.H1213-3BC53-3... 2190 2250 14.5 78 93.5 2500 1XB7 731 6SL3710-7LG32-2AA3 452 1.H1213-3BC73-3... 2340 2390 16.0 78 93.5 2500 1XB7 731 6SL3710-7LG32-6AA3 560 1.H1223-3AB13-2... 1240 1290 3.5 78 93 3000 1XB7 730 6SL3710-1GH32-6AA3 250 1.H1223-3AB33-2... 1420 1470 4.4 78 93 3000 1XB7 730 6SL3710-1GH33-3AA3 320 1.H1223-3AB53-2... 1600 1650 5.0 78 93 3000 1XB7 731 6SL3710-1GH34-1AA3 400 1.H1223-3AB73-2... 1770 1820 5.8 78 93 3000 1XB7 731 6SL3710-1GH34-7AA3 452 1.H1223-3BB53-2... 2200 2250 8.3 78 93.5 2600 1XB7 740 6SL3710-1GH37-4AA3 710 1.H1223-3BB73-2... 2320 2380 8.9 78 93.5 2600 1XB7 740 6SL3710-1GH37-4AA3 710 1.H1223-3AC13-3... 1270 1320 5.9 78 93 2600 1XB7 730 6SL3710-1GH32-6.A3 208 1.H1223-3AC33-3... 1450 1500 7.2 78 93 2600 1XB7 730 6SL3710-1GH33-3.A3 320 1.H1223-3AC53-3... 1630 1680 8.3 78 93 2600 1XB7 730 6SL3710-1GH34-1.A3 400 1.H1223-3AC73-3... 1740 1790 9.1 78 93 2600 1XB7 731 6SL3710-1GH34-1.A3 400 1.H1223-3BC53-3... 2190 2250 14.5 78 93.5 2500 1XB7 731 6SL3710-1GH32-6.A3 560 1.H1223-3BC73-3... 2340 2390 16.0 78 93.5 2500 1XB7 731 6SL3710-1GH33-3.A3 560 Siemens D 81.8 · 04/2014 6 6/13 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency ■ Selection and ordering data 6 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LH1/1MH1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V 3600 rpm, 4-pole 330 443 315 Δ 120.7 876 94.7 95.0 94.3 0.88 475 6.2 2.1 1■H1212-3AB15-5■■■ 415 557 315 Δ 120.6 1101 95.2 95.5 94.9 0.90 580 7.3 2.4 1■H1212-3AB35-5■■■ 435 583 315 Δ 120.7 1154 95.1 95.4 94.9 0.90 610 6.2 2.0 1■H1212-3AB55-5■■■ 500 671 315 Δ 120.7 1327 95.3 95.7 95.2 0.91 690 6.7 2.2 1■H1212-3AB75-5■■■ 3000 rpm, 4-pole 550 738 355 Δ 100.7 1752 95.2 95.9 95.6 0.89 780 5.0 1.8 1■H1212-3BB55-1■■■ 1■H1212-3BB75-1■■■ 620 831 355 Δ 100.6 1974 95.5 96.1 95.8 0.89 870 5.7 2.1 1800 rpm, 4-pole 365 489 315 Δ 60.7 1937 94.8 95.8 96.0 0.87 530 6.1 2.2 1■H1212-3AB15-6■■■ 1■H1212-3AB35-6■■■ 450 603 315 Δ 60.7 2388 95.0 96.0 96.2 0.89 630 6.3 2.2 1■H1212-3AB55-6■■■ 495 664 315 Δ 60.7 2626 95.0 96.0 96.2 0.90 690 6.4 2.2 630 845 315 Δ 60.6 3343 95.5 96.4 96.5 0.90 870 7.7 2.2 1■H1212-3AB75-6■■■ 665 892 355 Δ 60.5 3529 95.7 96.5 96.6 0.88 940 6.9 2.6 1■H1212-3BB55-6■■■ 1■H1212-3BB75-6■■■ 685 919 355 Δ 60.5 3635 95.5 96.5 96.6 0.89 960 6.3 2.3 1200 rpm, 6-pole 290 389 315 Δ 60.6 2308 94.5 95.6 95.9 0.82 445 6.1 1.9 1■H1212-3AC15-7■■■ 355 476 315 Δ 60.6 2826 94.8 95.7 96.1 0.84 530 6.3 1.9 1■H1212-3AC35-7■■■ 425 570 315 Δ 60.6 3385 95.1 96.1 96.2 0.84 630 6.8 2.0 1■H1212-3AC55-7■■■ 1■H1212-3AC75-7■■■ 455 610 315 Δ 60.6 3624 95.1 96.1 96.3 0.85 670 6.6 2.0 560 751 355 Δ 60.4 4459 95.2 96.1 96.1 0.86 820 7.9 2.2 1■H1212-3BC55-7■■■ 1■H1212-3BC75-7■■■ 610 818 355 Δ 60.4 4857 95.3 96.1 96.1 0.87 880 7.9 2.0 900 rpm, 6-pole 250 335 315 Δ 45.6 2653 93.7 94.9 95.4 0.81 390 6.0 2.0 1■H1212-3AC15-8■■■ 1■H1212-3AC35-8■■■ 315 422 315 Δ 45.6 3345 94.1 95.3 95.6 0.81 490 6.5 2.1 340 456 315 Δ 45.6 3608 94.0 95.2 95.6 0.84 510 5.9 1.9 1■H1212-3AC55-8■■■ 1■H1212-3AC75-8■■■ 380 510 315 Δ 45.6 4033 94.1 95.3 95.7 0.85 560 6.1 1.8 435 583 355 Δ 45.5 4617 94.1 95.3 95.6 0.87 630 6.8 2.1 1■H1212-3BC55-8■■■ 485 650 355 Δ 45.5 5147 94.4 95.5 95.7 0.87 700 7.1 1.9 1■H1212-3BC75-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V 3600 rpm, 4-pole 340 456 315 Δ 120.6 902 94.8 95.0 94.3 0.88 530 6.5 2.2 1■H1222-3AB15-5■■■ 405 543 315 Δ 120.7 1075 95.1 95.4 94.9 0.90 620 6.2 2.0 1■H1222-3AB35-5■■■ 445 597 315 Δ 120.6 1181 95.2 95.5 94.9 0.90 680 7.0 2.3 1■H1222-3AB55-5■■■ 1■H1222-3AB75-5■■■ 510 684 315 Δ 120.5 1353 95.5 95.8 95.1 0.91 770 8.0 2.6 3000 rpm, 4-pole 560 751 355 Δ 100.6 1783 95.4 96.0 95.6 0.89 860 5.6 2.0 1■H1222-3BB55-1■■■ 575 771 355 Δ 100.7 1831 95.3 96.0 95.7 0.89 880 5.2 1.8 1■H1222-3BB75-1■■■ 1800 rpm, 4-pole 365 489 315 Δ 60.7 1937 94.8 95.7 96.0 0.87 580 6.1 2.2 1■H1222-3AB15-6■■■ 455 610 315 Δ 60.6 2415 95.0 96.0 96.2 0.89 700 6.4 2.3 1■H1222-3AB35-6■■■ 510 684 315 Δ 60.6 2706 95.1 96.1 96.3 0.90 770 6.7 2.3 1■H1222-3AB55-6■■■ 590 791 315 Δ 60.6 3131 95.3 96.2 96.4 0.90 890 6.8 2.3 1■H1222-3AB75-6■■■ 625 838 355 Δ 60.6 3317 95.4 96.4 96.6 0.89 960 6.1 2.3 1■H1222-3BB55-6■■■ 710 952 355 Δ 60.5 3767 95.7 96.6 96.7 0.89 1080 7.0 2.6 1■H1222-3BB75-6■■■ 1200 rpm, 6-pole 305 409 315 Δ 60.6 2429 94.8 95.7 96.0 0.81 520 6.6 2.1 1■H1222-3AC15-7■■■ 360 483 315 Δ 60.6 2867 94.9 95.7 96.1 0.83 590 6.6 2.0 1■H1222-3AC35-7■■■ 415 557 315 Δ 60.6 3305 95.0 96.0 96.2 0.84 680 6.5 2.0 1■H1222-3AC55-7■■■ 465 624 315 Δ 60.6 3702 95.1 96.1 96.3 0.85 750 6.3 1.9 1■H1222-3AC75-7■■■ 550 738 355 Δ 60.4 4379 95.2 96.1 96.1 0.86 870 8.0 2.3 1■H1222-3BC55-7■■■ 1■H1222-3BC75-7■■■ 605 811 355 Δ 60.4 4817 95.3 96.2 96.1 0.87 950 7.9 2.1 900 rpm, 6-pole 245 329 315 Δ 45.6 2601 93.8 94.9 95.3 0.80 425 6.4 2.1 1■H1222-3AC15-8■■■ 305 409 315 Δ 45.6 3239 94.0 95.2 95.5 0.82 510 6.3 2.0 1■H1222-3AC35-8■■■ 345 463 315 Δ 45.6 3664 94.0 95.2 95.6 0.84 570 6.0 1.9 1■H1222-3AC55-8■■■ 375 503 315 Δ 45.6 3981 94.0 95.2 95.7 0.85 610 5.7 1.8 1■H1222-3AC75-8■■■ 440 590 355 Δ 45.5 4669 94.3 95.4 95.6 0.86 700 7.1 2.1 1■H1222-3BC55-8■■■ 500 671 355 Δ 45.4 5307 94.5 95.6 95.7 0.86 800 7.5 1.9 1■H1222-3BC75-8■■■ For versions, see Article No. supplements and special versions 1■H1222-3AC75-8■■■ Prated 6/14 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency Motor type mIM B3 mIM V1 J LpfA, LWA, Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 tolerance +3 dB(A) no-load Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.H1212-3AB15-5... 1.H1212-3AB35-5... 1.H1212-3AB55-5... 1.H1212-3AB75-5... 1240 1420 1600 1770 1290 1470 1650 1820 3.5 4.4 5.0 5.8 78 78 78 78 93 93 93 93 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 477 590 725 725 1.H1212-3BB55-1... 1.H1212-3BB75-1... 2200 2320 2250 2380 8.3 8.9 78 78 93.5 93.5 3300 3300 1XB7 740 1XB7 740 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 820 960 1.H1212-3AB15-6... 1.H1212-3AB35-6... 1.H1212-3AB55-6... 1.H1212-3AB75-6... 1.H1212-3BB55-6... 1.H1212-3BB75-6... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-0AA3 590 725 725 960 960 960 1.H1212-3AC15-7... 1.H1212-3AC35-7... 1.H1212-3AC55-7... 1.H1212-3AC75-7... 1.H1212-3BC55-7... 1.H1212-3BC75-7... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 477 590 725 725 820 960 1.H1212-3AC15-8... 1.H1212-3AC35-8... 1.H1212-3AC55-8... 1.H1212-3AC75-8... 1.H1212-3BC55-8... 1.H1212-3BC75-8... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 477 590 590 590 725 725 1.H1222-3AB15-5... 1.H1222-3AB35-5... 1.H1222-3AB55-5... 1.H1222-3AB75-5... 1240 1420 1600 1770 1290 1470 1650 1820 3.5 4.4 5.0 5.8 78 78 78 78 93 93 93 93 3600 3600 3600 3600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 590 725 725 820 1.H1222-3BB55-1... 1.H1222-3BB75-1... 2200 2320 2250 2380 8.3 8.9 78 78 93.5 93.5 3300 3300 1XB7 740 1XB7 740 6SL3710-1GE41-0AA3 6SL3710-1GE41-0AA3 960 960 1.H1222-3AB15-6... 1.H1222-3AB35-6... 1.H1222-3AB55-6... 1.H1222-3AB75-6... 1.H1222-3BB55-6... 1.H1222-3BB75-6... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 590 725 820 960 960 1092 1.H1222-3AC15-7... 1.H1222-3AC35-7... 1.H1222-3AC55-7... 1.H1222-3AC75-7... 1.H1222-3BC55-7... 1.H1222-3BC75-7... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-1GE41-0AA3 590 590 725 820 960 960 1.H1222-3AC15-8... 1.H1222-3AC35-8... 1.H1222-3AC55-8... 1.H1222-3AC75-8... 1.H1222-3BC55-8... 1.H1222-3BC75-8... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 477 590 590 725 725 820 Siemens D 81.8 · 04/2014 6 6/15 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 460 V, 60 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LH1/1MH1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V 1800 rpm, 4-pole 300 402 315 Δ 60.5 1592 95.3 96.2 96.2 0.86 435 7.4 2.7 1■H1213-3AB15-6■■■ 405 543 315 Δ 60.6 2149 95.3 96.2 96.4 0.89 570 7.0 2.5 1■H1213-3AB35-6■■■ 460 617 315 Δ 60.6 2441 95.2 96.2 96.4 0.90 640 6.9 2.4 1■H1213-3AB55-6■■■ 635 852 315 Δ 60.6 3370 95.5 96.4 96.6 0.90 880 7.6 2.2 1■H1213-3AB75-6■■■ 690 925 355 Δ 60.5 3661 95.8 96.7 96.9 0.88 980 6.6 2.5 1■H1213-3BB55-6■■■ 705 945 355 Δ 60.6 3741 95.6 96.6 96.9 0.89 990 6.1 2.3 1■H1213-3BB75-6■■■ 1200 rpm, 6-pole 6 270 362 315 Δ 60.6 2151 94.7 95.8 96.0 0.82 415 6.5 2.0 1■H1213-3AC15-7■■■ 360 483 315 Δ 60.6 2866 94.7 95.8 96.1 0.84 540 6.1 1.9 1■H1213-3AC35-7■■■ 435 583 315 Δ 60.6 3464 95.1 96.1 96.3 0.84 650 6.5 2.0 1■H1213-3AC55-7■■■ 460 617 315 Δ 60.6 3664 95.1 96.1 96.4 0.84 690 6.4 2.0 1■H1213-3AC75-7■■■ 585 784 355 Δ 60.5 4658 95.4 96.4 96.5 0.85 860 7.5 2.1 1■H1213-3BC55-7■■■ 635 852 355 Δ 60.5 5056 95.4 96.4 96.5 0.86 920 7.5 2.0 1■H1213-3BC75-7■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V 1800 rpm, 4-pole 295 396 315 Δ 60.5 1565 95.3 96.2 96.2 0.86 470 7.5 2.8 1■H1223-3AB15-6■■■ 420 563 315 Δ 60.6 2229 95.2 96.2 96.4 0.89 640 7.0 2.4 1■H1223-3AB35-6■■■ 495 664 315 Δ 60.6 2627 95.2 96.2 96.4 0.90 750 6.9 2.4 1■H1223-3AB55-6■■■ 595 798 315 Δ 60.6 3157 95.3 96.2 96.5 0.91 890 6.8 2.3 1■H1223-3AB75-6■■■ 640 858 355 Δ 60.6 3396 95.5 96.6 96.8 0.89 980 6.0 2.2 1■H1223-3BB55-6■■■ 735 986 355 Δ 60.5 3900 95.8 96.8 96.9 0.89 1120 6.8 2.5 1■H1223-3BB75-6■■■ 1200 rpm, 6-pole 310 416 315 Δ 60.6 2468 94.8 95.8 96.1 0.81 520 6.5 2.0 1■H1223-3AC15-7■■■ 365 489 315 Δ 60.6 2907 94.9 95.9 96.2 0.83 600 6.4 2.0 1■H1223-3AC35-7■■■ 420 563 315 Δ 60.6 3345 95.0 96.0 96.3 0.84 680 6.5 2.0 1■H1223-3AC55-7■■■ 470 630 315 Δ 60.6 3742 95.1 96.1 96.4 0.85 750 6.3 1.9 1■H1223-3AC75-7■■■ 575 771 355 Δ 60.5 4579 95.4 96.3 96.5 0.86 910 7.6 2.2 1■H1223-3BC55-7■■■ 635 852 355 Δ 60.5 5056 95.5 96.4 96.6 0.86 1000 7.5 2.0 1■H1223-3BC75-7■■■ For versions, see Article No. supplements and special versions 6/16 Siemens D 81.8 · 04/2014 1■H1223-3AC75-7■■■ © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 460 V, 60 Hz Premium Efficiency Motor type mIM B3 mIM V1 J Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.H1213-3AB15-6... 1240 1290 3.5 78 93 3000 1XB7 731 6SL3710-7LE35-0AA3 477 1.H1213-3AB35-6... 1420 1470 4.4 78 93 3000 1XB7 731 6SL3710-7LE36-1AA3 590 1.H1213-3AB55-6... 1600 1650 5.0 78 93 3000 1XB7 740 6SL3710-7LE37-5AA3 725 1.H1213-3AB75-6... 1770 1820 5.8 78 93 3000 1XB7 740 6SL3710-7LE41-0AA3 960 1.H1213-3BB55-6... 2200 2250 8.3 78 93.5 2600 1XB7 740 6SL3710-7LE41-2AA3 1230 1.H1213-3BB75-6... 2320 2380 8.9 78 93.5 2600 1XB7 740 6SL3710-7LE41-2AA3 1230 1.H1213-3AC15-7... 1270 1320 5.9 78 93 2600 1XB7 731 6SL3710-7LE35-0AA3 477 1.H1213-3AC35-7... 1450 1500 7.2 78 93 2600 1XB7 731 6SL3710-7LE36-1AA3 590 1.H1213-3AC55-7... 1630 1680 8.3 78 93 2600 1XB7 740 6SL3710-7LE37-5AA3 725 1.H1213-3AC75-7... 1740 1790 9.1 78 93 2600 1XB7 740 6SL3710-7LE37-5AA3 725 1.H1213-3BC55-7... 2190 2250 14.5 78 93.5 2500 1XB7 740 6SL3710-7LE41-0AA3 960 1.H1213-3BC75-7... 2340 2390 16.0 78 93.5 2500 1XB7 740 6SL3710-7LE41-0AA3 960 1.H1223-3AB15-6... 1240 1290 3.5 78 93 3000 1XB7 731 6SL3710-1GE35-0AA3 477 1.H1223-3AB35-6... 1420 1470 4.4 78 93 3000 1XB7 740 6SL3710-1GE37-5AA3 725 1.H1223-3AB55-6... 1600 1650 5.0 78 93 3000 1XB7 740 6SL3710-1GE38-4AA3 820 1.H1223-3AB75-6... 1770 1820 5.8 78 93 3000 1XB7 740 6SL3710-1GE41-0AA3 960 1.H1223-3BB55-6... 2200 2250 8.3 78 93.5 2600 1XB7 740 6SL3710-2GE41-1AA3 1092 1.H1223-3BB75-6... 2320 2380 8.9 78 93.5 2600 2 x 1XB7 740 6SL3710-2GE41-4AA3 1340 1.H1223-3AC15-7... 1270 1320 5.9 78 93 2600 1XB7 731 6SL3710-1GE36-1AA3 590 1.H1223-3AC35-7... 1450 1500 7.2 78 93 2600 1XB7 740 6SL3710-1GE37-5AA3 725 1.H1223-3AC55-7... 1630 1680 8.3 78 93 2600 1XB7 740 6SL3710-1GE37-5AA3 725 1.H1223-3AC75-7... 1740 1790 9.1 78 93 2600 1XB7 740 6SL3710-1GE38-4AA3 820 1.H1223-3BC55-7... 2190 2250 14.5 78 93.5 2500 1XB7 740 6SL3710-1GE41-0AA3 960 1.H1223-3BC75-7... 2340 2390 16.0 78 93.5 2500 1XB7 740 6SL3710-2GE41-1AA3 1092 Siemens D 81.8 · 04/2014 6 6/17 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency ■ Selection and ordering data 6 Operating values at rated output Frame Confrated Trated ηrated, ηrated, size nection 5/4 4/4 1LH1/1MH1 cast-iron series specially designed for converter-fed operation 3/4 ted, 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V 3600 rpm, 4-pole 315 422 315 Δ 120.7 836 94.4 94.8 94.1 0.88 355 5.9 2.0 1■H1212-3AB16-5■■■ 400 536 315 Δ 120.6 1061 95.1 95.4 94.7 0.90 440 7.3 2.4 1■H1212-3AB36-5■■■ 440 590 315 Δ 120.6 1167 95.1 95.4 94.7 0.90 485 7.7 2.5 1■H1212-3AB56-5■■■ 505 677 315 Δ 120.5 1340 95.4 95.7 95.1 0.91 550 7.9 2.6 1■H1212-3AB76-5■■■ 3000 rpm, 4-pole 530 711 355 Δ 100.7 1688 95.1 95.8 95.5 0.89 590 5.0 1.8 1■H1212-3BB56-1■■■ 1■H1212-3BB76-1■■■ 585 784 355 Δ 100.6 1863 95.3 95.9 95.7 0.89 650 5.5 2.0 1800 rpm, 4-pole 330 443 315 Δ 60.7 1752 94.5 95.6 95.8 0.88 370 6.2 2.2 1■H1212-3AB16-6■■■ 1■H1212-3AB36-6■■■ 440 590 315 Δ 60.6 2335 95.1 96.0 96.2 0.89 485 7.3 2.6 1■H1212-3AB56-6■■■ 475 637 315 Δ 60.6 2521 95.1 96.0 96.2 0.90 520 7.3 2.5 580 778 315 Δ 60.5 3077 95.5 96.3 96.4 0.90 630 8.2 2.4 1■H1212-3AB76-6■■■ 620 831 355 Δ 60.5 3290 95.6 96.5 96.5 0.88 690 7.2 2.7 1■H1212-3BB56-6■■■ 1■H1212-3BB76-6■■■ 680 912 355 Δ 60.4 3608 95.7 96.6 96.6 0.88 760 7.8 2.7 1200 rpm, 6-pole 275 369 315 Δ 60.6 2191 94.6 95.6 95.8 0.82 330 7.0 2.1 1■H1212-3AC16-7■■■ 335 449 315 Δ 60.5 2668 94.9 95.7 96.0 0.83 400 7.1 2.2 1■H1212-3AC36-7■■■ 380 510 315 Δ 60.6 3026 94.9 95.9 96.1 0.84 445 6.7 2.0 1■H1212-3AC56-7■■■ 1■H1212-3AC76-7■■■ 420 563 315 Δ 60.5 3345 95.0 96.0 96.1 0.85 485 7.0 2.1 525 704 355 Δ 60.4 4180 95.2 96.0 95.9 0.85 610 8.9 2.4 1■H1212-3BC56-7■■■ 1■H1212-3BC76-7■■■ 570 764 355 Δ 60.4 4538 95.2 96.1 96.0 0.86 650 8.7 2.2 900 rpm, 6-pole 225 302 315 Y 45.6 2390 93.5 94.7 95.1 0.81 280 6.3 2.1 1■H1212-3AC16-8■■■ 1■H1212-3AC36-8■■■ 295 396 315 Δ 45.5 3132 94.1 95.2 95.5 0.82 360 6.8 2.2 325 436 315 Δ 45.6 3451 94.0 95.2 95.6 0.84 385 6.4 2.0 1■H1212-3AC56-8■■■ 1■H1212-3AC76-8■■■ 360 483 315 Δ 45.5 3823 94.2 95.3 95.6 0.84 425 6.8 1.9 410 550 355 Δ 45.4 4353 94.3 95.3 95.5 0.86 475 7.7 2.3 1■H1212-3BC56-8■■■ 455 610 355 Δ 45.4 4830 94.4 95.4 95.6 0.87 520 7.8 2.0 1■H1212-3BC76-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V 3600 rpm, 4-pole 315 422 315 Δ 120.6 836 94.6 94.8 94.1 0.89 390 7.2 2.4 1■H1222-3AB16-5■■■ 385 516 315 Δ 120.5 1021 95.1 95.3 94.6 0.89 475 7.8 2.6 1■H1222-3AB36-5■■■ 420 563 315 Δ 120.5 1114 95.1 95.3 94.6 0.90 510 8.6 2.8 1■H1222-3AB56-5■■■ 1■H1222-3AB76-5■■■ 465 624 315 Δ 120.6 1234 95.2 95.5 95.0 0.91 560 6.9 2.2 3000 rpm, 4-pole 520 697 355 Δ 100.7 1656 95.1 95.8 95.5 0.89 640 5.3 1.9 1■H1222-3BB56-1■■■ 575 771 355 Δ 100.6 1831 95.4 96.0 95.6 0.89 710 5.9 2.1 1■H1222-3BB76-1■■■ 1800 rpm, 4-pole 320 429 315 Δ 60.7 1699 94.5 95.5 95.8 0.88 400 5.9 2.1 1■H1222-3AB16-6■■■ 425 570 315 Δ 60.6 2256 95.1 96.0 96.1 0.89 520 7.2 2.5 1■H1222-3AB36-6■■■ 470 630 315 Δ 60.6 2494 95.1 96.0 96.2 0.90 570 7.2 2.5 1■H1222-3AB56-6■■■ 580 778 315 Δ 60.5 3078 95.5 96.3 96.4 0.89 710 8.3 2.4 1■H1222-3AB76-6■■■ 615 825 355 Δ 60.5 3263 95.6 96.5 96.5 0.88 760 7.5 2.8 1■H1222-3BB56-6■■■ 635 852 355 Δ 60.5 3369 95.5 96.5 96.6 0.89 780 6.8 2.5 1■H1222-3BB76-6■■■ 1200 rpm, 6-pole 260 349 315 Δ 60.6 2070 94.3 95.4 95.7 0.83 345 6.4 1.9 1■H1222-3AC16-7■■■ 330 443 315 Δ 60.5 2628 94.9 95.7 96.0 0.83 435 7.1 2.2 1■H1222-3AC36-7■■■ 375 503 315 Δ 60.6 2986 94.9 95.7 96.1 0.85 490 6.8 2.1 1■H1222-3AC56-7■■■ 420 563 315 Δ 60.5 3344 95.1 96.0 96.2 0.84 550 7.0 2.2 1■H1222-3AC76-7■■■ 505 677 355 Δ 60.4 4021 95.1 96.0 95.9 0.86 640 8.6 2.5 1■H1222-3BC56-7■■■ 1■H1222-3BC76-7■■■ 555 744 355 Δ 60.3 4418 95.4 96.1 95.9 0.85 710 9.6 2.2 900 rpm, 6-pole 225 302 315 Δ 45.5 2389 93.7 94.9 95.1 0.80 310 6.9 2.3 1■H1222-3AC16-8■■■ 285 382 315 Δ 45.5 3026 94.0 95.1 95.4 0.80 395 7.0 2.3 1■H1222-3AC36-8■■■ 325 436 315 Δ 45.5 3451 94.0 95.2 95.5 0.83 430 6.7 2.1 1■H1222-3AC56-8■■■ 355 476 315 Δ 45.5 3770 94.2 95.3 95.6 0.84 465 6.8 2.0 1■H1222-3AC76-8■■■ 405 543 355 Δ 45.4 4299 94.3 95.3 95.5 0.86 520 7.6 2.3 1■H1222-3BC56-8■■■ 445 597 355 Δ 45.4 4723 94.4 95.4 95.6 0.87 560 8.0 2.1 1■H1222-3BC76-8■■■ For versions, see Article No. supplements and special versions 1■H1222-3AC76-8■■■ Prated 6/18 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕra- Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.H1212-3AB16-5... 1.H1212-3AB36-5... 1.H1212-3AB56-5... 1.H1212-3AB76-5... 1240 1420 1600 1770 1290 1470 1650 1820 3.5 4.4 5.0 5.8 78 78 78 78 93 93 93 93 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 400 452 560 560 1.H1212-3BB56-1... 1.H1212-3BB76-1... 2200 2320 2250 2380 8.3 8.9 78 78 93.5 93.5 3300 3300 1XB7 731 1XB7 740 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 710 710 1.H1212-3AB16-6... 1.H1212-3AB36-6... 1.H1212-3AB56-6... 1.H1212-3AB76-6... 1.H1212-3BB56-6... 1.H1212-3BB76-6... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 400 560 560 710 710 790 1.H1212-3AC16-7... 1.H1212-3AC36-7... 1.H1212-3AC56-7... 1.H1212-3AC76-7... 1.H1212-3BC56-7... 1.H1212-3BC76-7... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 400 400 452 560 710 710 1.H1212-3AC16-8... 1.H1212-3AC36-8... 1.H1212-3AC56-8... 1.H1212-3AC76-8... 1.H1212-3BC56-8... 1.H1212-3BC76-8... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 320 400 400 452 560 560 1.H1222-3AB16-5... 1.H1222-3AB36-5... 1.H1222-3AB56-5... 1.H1222-3AB76-5... 1240 1420 1600 1770 1290 1470 1650 1820 3.5 4.4 5.0 5.8 78 78 78 78 93 93 93 93 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GF34-1AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 400 560 560 560 1.H1222-3BB56-1... 1.H1222-3BB76-1... 2200 2320 2250 2380 8.3 8.9 78 78 93.5 93.5 3300 3300 1XB7 740 1XB7 740 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 710 710 1.H1222-3AB16-6... 1.H1222-3AB36-6... 1.H1222-3AB56-6... 1.H1222-3AB76-6... 1.H1222-3BB56-6... 1.H1222-3BB76-6... 1240 1420 1600 1770 2200 2320 1290 1470 1650 1820 2250 2380 3.5 4.4 5.0 5.8 8.3 8.9 78 78 78 78 78 78 93 93 93 93 93.5 93.5 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GF34-1AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 6SL3710-1GF38-1AA3 6SL3710-1GF38-1AA3 400 560 710 710 790 790 1.H1222-3AC16-7... 1.H1222-3AC36-7... 1.H1222-3AC56-7... 1.H1222-3AC76-7... 1.H1222-3BC56-7... 1.H1222-3BC76-7... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 400 452 560 560 710 710 1.H1222-3AC16-8... 1.H1222-3AC36-8... 1.H1222-3AC56-8... 1.H1222-3AC76-8... 1.H1222-3BC56-8... 1.H1222-3BC76-8... 1270 1450 1630 1740 2190 2340 1320 1500 1680 1790 2250 2390 5.9 7.2 8.3 9.1 14.5 16.0 78 78 78 78 78 78 93 93 93 93 93.5 93.5 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GF33-3AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 320 400 452 560 560 560 Siemens D 81.8 · 04/2014 6 6/19 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 575 V, 60 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated kW Prated hp Frame Confrated size nection Hz FS Trated Nm ηrated, ηrated, ηrated, cosϕra- Irated 5/4 4/4 3/4 ted, 4/4 % % % ILR/ Irated TB/ Trated A 1LH1/1MH1 cast-iron series specially designed for converter-fed operation Article No. L without explosion protection M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V 1800 rpm, 4-pole 255 342 315 Δ 60.5 1353 95.1 96.2 96.0 0.86 290 7.9 2.8 1■H1213-3AB16-6■■■ 400 536 315 Δ 60.5 2122 95.3 96.2 96.3 0.88 445 7.9 2.8 1■H1213-3AB36-6■■■ 445 597 315 Δ 60.5 2361 95.3 96.2 96.3 0.89 490 7.7 2.7 1■H1213-3AB56-6■■■ 585 784 315 Δ 60.5 3104 95.4 96.3 96.5 0.89 650 7.8 2.4 1■H1213-3AB76-6■■■ 640 858 355 Δ 60.5 3396 95.7 96.6 96.8 0.88 710 7.0 2.6 1■H1213-3BB56-6■■■ 710 952 355 Δ 60.5 3767 95.9 96.8 96.9 0.88 790 7.5 2.6 1■H1213-3BB76-6■■■ 1200 rpm, 6-pole 6 275 369 315 Δ 60.6 2190 94.7 95.8 96.0 0.82 330 7.0 2.1 1■H1213-3AC16-7■■■ 335 449 315 Δ 60.5 2668 94.9 95.9 96.1 0.83 400 7.1 2.2 1■H1213-3AC36-7■■■ 385 516 315 Δ 60.6 3066 94.8 95.9 96.2 0.84 450 6.6 2.0 1■H1213-3AC56-7■■■ 425 570 315 Δ 60.6 3384 95.0 96.0 96.3 0.85 495 6.8 2.1 1■H1213-3AC76-7■■■ 550 738 355 Δ 60.4 4378 95.4 96.3 96.4 0.84 640 8.5 2.3 1■H1213-3BC56-7■■■ 595 798 355 Δ 60.4 4737 95.4 96.4 96.5 0.86 680 8.3 2.1 1■H1213-3BC76-7■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V 1800 rpm, 4-pole 230 308 315 Δ 60.5 1220 95.2 96.2 96.0 0.87 290 8.1 2.9 1■H1223-3AB16-6■■■ 385 516 315 Δ 60.5 2043 95.4 96.2 96.3 0.88 475 7.9 2.8 1■H1223-3AB36-6■■■ 435 583 315 Δ 60.5 2308 95.3 96.2 96.3 0.89 530 7.8 2.7 1■H1223-3AB56-6■■■ 585 784 315 Δ 60.5 3104 95.5 96.3 96.5 0.89 720 8.1 2.4 1■H1223-3AB76-6■■■ 640 858 355 Δ 60.5 3396 95.7 96.7 96.8 0.88 790 7.2 2.7 1■H1223-3BB56-6■■■ 650 872 355 Δ 60.5 3449 95.6 96.6 96.8 0.89 790 6.7 2.5 1■H1223-3BB76-6■■■ 1200 rpm, 6-pole 235 315 315 Δ 60.5 1872 94.7 95.8 96.0 0.82 315 7.0 2.2 1■H1223-3AC16-7■■■ 340 456 315 Δ 60.5 2708 94.8 95.8 96.1 0.83 450 6.8 2.1 1■H1223-3AC36-7■■■ 380 510 315 Δ 60.6 3026 94.9 95.9 96.2 0.84 495 6.7 2.0 1■H1223-3AC56-7■■■ 430 577 315 Δ 60.5 3424 95.0 96.0 96.3 0.84 560 6.9 2.1 1■H1223-3AC76-7■■■ 525 704 355 Δ 60.4 4180 95.3 96.3 96.4 0.85 670 8.2 2.4 1■H1223-3BC56-7■■■ 585 784 355 Δ 60.4 4657 95.6 96.4 96.4 0.84 760 9.0 2.1 1■H1223-3BC76-7■■■ For versions, see Article No. supplements and special versions 6/20 Siemens D 81.8 · 04/2014 1■H1223-3AC76-7■■■ © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for converter-fed operation Line voltage 575 V, 60 Hz Premium Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current also possible IL LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.H1213-3AB16-6... 1240 1290 3.5 78 93 3000 1XB7 730 6SL3710-7LG33-3AA3 320 1.H1213-3AB36-6... 1420 1470 4.4 78 93 3000 1XB7 731 6SL3710-7LG34-7AA3 452 1.H1213-3AB56-6... 1600 1650 5.0 78 93 3000 1XB7 731 6SL3710-7LG35-8AA3 560 1.H1213-3AB76-6... 1770 1820 5.8 78 93 3000 1XB7 740 6SL3710-7LG37-4AA3 710 1.H1213-3BB56-6... 2200 2250 8.3 78 93.5 2600 1XB7 740 6SL3710-7LG37-4AA3 710 1.H1213-3BB76-6... 2320 2380 8.9 78 93.5 2600 1XB7 740 6SL3710-7LG38-1AA3 790 1.H1213-3AC16-7... 1270 1320 5.9 78 93 2600 1XB7 730 6SL3710-7LG34-1AA3 400 1.H1213-3AC36-7... 1450 1500 7.2 78 93 2600 1XB7 731 6SL3710-7LG34-1AA3 400 1.H1213-3AC56-7... 1630 1680 8.3 78 93 2600 1XB7 731 6SL3710-7LG34-7AA3 452 1.H1213-3AC76-7... 1740 1790 9.1 78 93 2600 1XB7 731 6SL3710-7LG35-8AA3 560 1.H1213-3BC56-7... 2190 2250 14.5 78 93.5 2500 1XB7 740 6SL3710-7LG37-4AA3 710 1.H1213-3BC76-7... 2340 2390 16.0 78 93.5 2500 1XB7 740 6SL3710-7LG37-4AA3 710 1.H1223-3AB16-6... 1240 1290 3.5 78 93 3000 1XB7 730 6SL3710-1GF33-3AA3 320 1.H1223-3AB36-6... 1420 1470 4.4 78 93 3000 1XB7 731 6SL3710-1GF35-8AA3 560 1.H1223-3AB56-6... 1600 1650 5.0 78 93 3000 1XB7 731 6SL3710-1GF35-8AA3 560 1.H1223-3AB76-6... 1770 1820 5.8 78 93 3000 1XB7 740 6SL3710-1GF38-1AA3 790 1.H1223-3BB56-6... 2200 2250 8.3 78 93.5 2600 1XB7 740 6SL3710-1GF38-1AA3 790 1.H1223-3BB76-6... 2320 2380 8.9 78 93.5 2600 1XB7 740 6SL3710-1GF38-1AA3 790 1.H1223-3AC16-7... 1270 1320 5.9 78 93 2600 1XB7 730 6SL3710-1GF33-3AA3 320 1.H1223-3AC36-7... 1450 1500 7.2 78 93 2600 1XB7 731 6SL3710-1GF34-7AA3 452 1.H1223-3AC56-7... 1630 1680 8.3 78 93 2600 1XB7 731 6SL3710-1GF35-8AA3 560 1.H1223-3AC76-7... 1740 1790 9.1 78 93 2600 1XB7 731 6SL3710-1GF35-8AA3 560 1.H1223-3BC56-7... 2190 2250 14.5 78 93.5 2500 1XB7 740 6SL3710-1GF37-4AA3 710 1.H1223-3BC76-7... 2340 2390 16.0 78 93.5 2500 1XB7 740 6SL3710-1GF38-1AA3 790 Siemens D 81.8 · 04/2014 6 6/21 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for mains-fed operation Line voltage 400 V, 50 Hz High Efficiency ■ Selection and ordering data Operating values at rated output Prated Prated Frame Con- frated size nection kW hp Hz FS Trated 1LH1/1MH1 cast-iron series specially designed for mains-fed operation Effiηrated, ηrated, ηrated, cosϕra- Irated ciency 5/4 4/4 3/4 ted, 4/4 class Nm % % % ILR/ Irated TLR/ TB/ Trated Trated Article No. L without explosion protection M with explosion protection A • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) approx. 1500 rpm, 4-pole 6 265 355 315 Δ 50 1708 IE2 94.3 95.4 95.8 0.87 460 5.8 1.3 2.0 1■H1202-3AB11-2■■■ 355 476 315 Δ 50 2286 IE2 94.8 95.8 96.1 0.88 610 6.5 1.5 2.2 1■H1202-3AB31-2■■■ 425 570 315 Δ 50 2731 – 95.2 95.9 96.2 0.87 740 7.6 1.8 2.6 1■H1202-3AB51-2■■■ 490 657 315 Δ 50 3149 – 95.3 95.9 96.3 0.88 840 7.8 1.9 2.7 1■H1202-3AB71-2■■■ 510 684 355 Δ 50 3281 – 95.0 96.1 96.5 0.87 880 5.6 1.3 2.0 1■H1202-3BB51-2■■■ 575 771 355 Δ 50 3696 – 95.3 96.3 96.6 0.88 980 6.2 1.5 2.2 1■H1202-3BB71-2■■■ approx. 1000 rpm, 6-pole 230 308 315 Δ 50 2222 IE2 94.2 95.3 95.6 0.82 425 6.7 1.4 2.3 1■H1202-3AC11-3■■■ 285 382 315 Δ 50 2752 IE2 94.5 95.5 95.8 0.84 510 6.9 1.4 2.3 1■H1202-3AC31-3■■■ 325 436 315 Δ 50 3138 IE2 94.6 95.6 95.9 0.85 580 6.7 1.3 2.2 1■H1202-3AC51-3■■■ 395 530 315 Δ 50 3807 – 95.0 95.7 96.0 0.83 720 7.7 1.7 2.6 1■H1202-3AC71-3■■■ 495 664 355 Δ 50 4770 – 94.7 95.8 96.0 0.84 890 7.1 1.6 2.0 1■H1202-3BC51-3■■■ 530 711 355 Δ 50 5106 – 94.9 95.9 96.1 0.85 940 7.2 1.6 2.0 1■H1202-3BC71-3■■■ approx. 750 rpm, 8-pole 160 215 315 Δ 50 2057 – 93.7 94.8 94.8 0.75 325 5.8 1.2 2.0 1■H1202-3AD11-4■■■ 235 315 315 Δ 50 3027 – 93.6 94.8 94.9 0.76 470 5.4 1.1 1.9 1■H1202-3AD31-4■■■ 295 396 315 Δ 50 3804 – 93.4 94.8 95.0 0.77 580 5.2 1.1 1.8 1■H1202-3AD51-4■■■ 325 436 315 Δ 50 4191 – 93.5 94.8 95.1 0.78 630 5.2 1.1 1.8 1■H1202-3AD71-4■■■ 385 516 355 Δ 50 4978 – 93.0 94.2 94.8 0.81 730 4.5 0.9 1.4 1■H1202-3BD51-4■■■ 420 563 355 Δ 50 5430 – 93.1 94.3 94.9 0.81 790 4.5 0.9 1.4 1■H1202-3BD71-4■■■ For versions, see Article No. supplements and special versions 6/22 Siemens D 81.8 · 04/2014 1■H1202-3AD71-4■■■ © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for mains-fed operation Line voltage 400 V, 50 Hz High Efficiency Motor type mIM B3 mIM V1 Blocking time Admissible moment of inertia and start-up times when starting up the motor cold warm 3 × cold tBr tBr Jadm 2 × warm tst Jadm tst J LpfA, LWA, tolerance +3 dB(A) no-load tolerance +3 dB(A) no-load Terminal box kgm2 s kgm2 s kgm2 dB(A) dB(A) Type 12.5 270 30.5 105 11.5 3.5 73 88 GT 640 9.5 340 24.0 130 9.0 4.4 73 88 1XB1 631 17.5 6.0 375 18.0 150 7.0 5.0 73 88 1XB1 631 15.5 5.0 425 17.0 175 7.0 5.8 73 88 1XB1 631 2250 28.5 7.5 620 37.5 260 15.5 8.3 73 88.5 1XB1 631 2320 2380 21.0 5.5 595 28.5 260 12.0 8.9 73 88.5 1XB1 631 1.H1202-3AC11-3... 1270 1320 26.5 9.5 460 23.0 185 9.0 5.9 68 83 GT 640 1.H1202-3AC31-3... 1450 1500 25.0 9.0 540 21.5 215 8.0 7.2 68 83 GT 640 1.H1202-3AC51-3... 1630 1680 26.5 9.5 640 23.0 255 9.0 8.3 68 83 1XB1 621 1.H1202-3AC71-3... 1740 1790 20.5 7.5 755 18.0 305 7.0 9.1 68 83 1XB1 631 1.H1202-3BC51-3... 2190 2250 20.5 7.0 670 18.0 305 8.0 14.5 68 83.5 1XB1 631 1.H1202-3BC71-3... 2340 2390 20.5 7.5 715 17.5 340 8.0 16.0 68 83.5 1XB1 631 1.H1202-3AD11-4... 1270 1320 40.5 23.5 1035 45.0 675 28.0 5.9 72 82 GT 640 1.H1202-3AD31-4... 1450 1500 35.0 16.0 1155 37.0 555 16.5 7.2 72 82 GT 640 1.H1202-3AD51-4... 1630 1680 33.5 12.5 1255 34.0 500 12.5 8.3 72 82 1XB1 621 1.H1202-3AD71-4... 1740 1790 34.0 12.5 1350 33.5 540 12.5 9.1 72 82 1XB1 631 1.H1202-3BD51-4... 2190 2250 37.5 13.5 1030 36.0 460 14.5 14.5 72 87.5 1XB1 631 1.H1202-3BD71-4... 2340 2390 38.0 14.0 1135 36.5 520 15.0 16.0 72 87.5 1XB1 631 kg kg s s 1.H1202-3AB11-2... 1240 1290 36.0 1.H1202-3AB31-2... 1420 1470 26.5 1.H1202-3AB51-2... 1600 1650 1.H1202-3AB71-2... 1770 1820 1.H1202-3BB51-2... 2200 1.H1202-3BB71-2... Siemens D 81.8 · 04/2014 6/23 6 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for mains-fed operation Line voltage 400 V, 50 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated Prated Frame Con- frated size nection kW hp Hz FS Trated 1LH1/1MH1 cast-iron series specially designed for mains-fed operation Effiηrated, ηrated, ηrated, cosϕra- Irated ciency 5/4 4/4 3/4 ted, 4/4 class Nm % % % ILR/ Irated TLR/ TB/ Trated Trated Article No. L without explosion protection M with explosion protection A • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) approx. 1500 rpm, 4-pole 285 382 315 Δ 50 1830 IE3 95.1 96.0 96.1 0.82 520 7.4 1.7 2.7 1■H1203-3AB11-2■■■ 380 510 315 Δ 50 2443 – 95.2 96.1 96.3 0.86 660 7.4 1.7 2.6 1■H1203-3AB31-2■■■ 430 577 315 Δ 50 2764 – 95.2 96.2 96.4 0.87 740 7.6 1.8 2.6 1■H1203-3AB51-2■■■ 495 664 315 Δ 50 3181 – 95.4 96.3 96.5 0.88 840 7.8 1.9 2.6 1■H1203-3AB71-2■■■ 555 744 355 Δ 50 3565 – 95.5 96.6 96.8 0.87 950 6.4 1.5 2.3 1■H1203-3BB71-2■■■ approx. 1000 rpm, 6-pole 6 225 302 315 Δ 50 2167 IE3 94.9 95.8 95.8 0.78 435 7.5 1.7 2.8 1■H1203-3AC11-3■■■ 310 416 315 Δ 50 2987 IE3 94.9 95.9 96.0 0.80 580 7.7 1.7 2.7 1■H1203-3AC31-3■■■ 355 476 315 Δ 50 3420 IE3 95.1 96.0 96.1 0.81 660 7.8 1.7 2.7 1■H1203-3AC51-3■■■ 405 543 315 Δ 50 3905 – 95.1 96.1 96.2 0.83 730 7.6 1.6 2.6 1■H1203-3AC71-3■■■ 475 637 355 Δ 50 4578 – 95.0 96.1 96.3 0.83 860 7.4 1.6 2.1 1■H1203-3BC51-3■■■ 510 684 355 Δ 50 4911 – 95.1 96.2 96.4 0.84 910 7.5 1.6 2.1 1■H1203-3BC71-3■■■ For versions, see Article No. supplements and special versions 6/24 Siemens D 81.8 · 04/2014 1■H1203-3AC71-3■■■ © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for mains-fed operation Line voltage 400 V, 50 Hz Premium Efficiency Motor type mIM B3 mIM V1 Blocking time Admissible moment of inertia and start-up times when starting up the motor cold warm 3 × cold tBr tBr Jadm 2 × warm tst Jadm tst J LpfA, LWA, tolerance +3 dB(A) no-load tolerance +3 dB(A) no-load Terminal box kg kg s s kgm2 s kgm2 s kgm2 dB(A) dB(A) Type 1.H1203-3AB11-2... 1240 1290 22.0 9.5 280 21.0 130 9.5 3.5 73 88 1XB1 621 1.H1203-3AB31-2... 1420 1470 19.0 7.0 310 18.0 130 7.5 4.4 73 88 1XB1 631 1.H1203-3AB51-2... 1600 1650 17.5 6.0 370 18.0 150 7.0 5.0 73 88 1XB1 631 1.H1203-3AB71-2... 1770 1820 15.5 5.5 395 16.0 170 6.5 5.8 73 88 1XB1 631 1.H1203-3BB71-2... 2320 2380 21.0 6.5 600 29.0 325 15.0 8.9 73 88.5 1XB1 631 1.H1203-3AC11-3... 1270 1320 21.5 10.0 495 19.5 255 9.5 5.9 68 83 GT 640 1.H1203-3AC31-3... 1450 1500 20.0 7.0 565 17.0 230 6.5 7.2 68 83 1XB1 621 1.H1203-3AC51-3... 1630 1680 19.0 7.0 605 16.0 255 6.5 8.3 68 83 1XB1 631 1.H1203-3AC71-3... 1740 1790 20.5 7.5 740 18.0 300 7.0 9.1 68 83 1XB1 631 1.H1203-3BC51-3... 2190 2250 20.5 9.0 690 18.5 380 10.0 14.5 68 83.5 1XB1 631 1.H1203-3BC71-3... 2340 2390 20.5 9.0 735 18.0 410 10.0 16.0 68 83.5 1XB1 631 Siemens D 81.8 · 04/2014 6/25 6 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for mains-fed operation Line voltage 690 V, 50 Hz High Efficiency ■ Selection and ordering data Operating values at rated output Prated Prated Frame Con- frated size nection kW hp Hz FS Trated 1LH1/1MH1 cast-iron series specially designed for mains-fed operation Effiηrated, ηrated, ηrated, cosϕra- Irated ciency 5/4 4/4 3/4 ted, 4/4 class Nm % % % ILR/ Irated TLR/ TB/ Trated Trated Article No. L without explosion protection M with explosion protection A • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) approx. 1500 rpm, 4-pole 6 265 355 315 Y 50 1708 IE2 94.2 95.4 95.8 0.87 265 5.8 1.2 2.0 1■H1202-3AB14-2■■■ 355 476 315 Y 50 2286 IE2 94.8 95.8 96.1 0.88 350 6.5 1.5 2.2 1■H1202-3AB34-2■■■ 425 570 315 Y 50 2732 – 95.1 95.9 96.2 0.87 425 7.6 1.8 2.6 1■H1202-3AB54-2■■■ 490 657 315 Y 50 3149 – 95.3 95.9 96.3 0.88 485 7.8 1.9 2.6 1■H1202-3AB74-2■■■ 510 684 355 Y 50 3282 – 95.0 96.1 96.4 0.87 510 5.5 1.3 2.0 1■H1202-3BB54-2■■■ 575 771 355 Y 50 3697 – 95.3 96.3 96.6 0.88 570 6.1 1.5 2.2 1■H1202-3BB74-2■■■ approx. 1000 rpm, 6-pole 230 308 315 Y 50 2222 IE2 94.2 95.3 95.6 0.82 245 6.7 1.4 2.3 1■H1202-3AC14-3■■■ 285 382 315 Y 50 2752 IE2 94.4 95.5 95.8 0.84 295 6.8 1.4 2.3 1■H1202-3AC34-3■■■ 325 436 315 Y 50 3139 IE2 94.5 95.6 95.9 0.85 335 6.6 1.3 2.2 1■H1202-3AC54-3■■■ 395 530 315 Y 50 3807 – 95.0 95.7 96.0 0.83 415 7.7 1.6 2.6 1■H1202-3AC74-3■■■ 490 657 355 Y 50 4722 – 94.7 95.8 96.0 0.84 510 7.1 1.6 2.0 1■H1202-3BC54-3■■■ 530 711 355 Y 50 5107 – 94.8 95.9 96.1 0.85 540 7.2 1.6 2.0 1■H1202-3BC74-3■■■ approx. 750 rpm, 8-pole 160 215 315 Y 50 2058 – 93.7 94.8 94.9 0.75 188 5.8 1.2 2.0 1■H1202-3AD14-4■■■ 235 315 315 Y 50 3027 – 93.5 94.8 94.9 0.76 275 5.3 1.1 1.9 1■H1202-3AD34-4■■■ 295 396 315 Y 50 3805 – 93.4 94.8 95.0 0.77 340 5.1 1.1 1.8 1■H1202-3AD54-4■■■ 325 436 315 Y 50 4192 – 93.5 94.8 95.1 0.78 370 5.1 1.1 1.8 1■H1202-3AD74-4■■■ 385 516 355 Y 50 4979 – 92.9 94.2 94.8 0.81 420 4.4 0.9 1.4 1■H1202-3BD54-4■■■ 420 563 355 Y 50 5431 – 93.1 94.3 94.9 0.81 460 4.4 0.9 1.4 1■H1202-3BD74-4■■■ For versions, see Article No. supplements and special versions 6/26 Siemens D 81.8 · 04/2014 1■H1202-3AD74-4■■■ © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for mains-fed operation Line voltage 690 V, 50 Hz High Efficiency Motor type mIM B3 kg mIM V1 kg Blocking time Admissible moment of inertia and start-up times when starting up the motor cold warm 3 × cold tBr tBr Jadm s s kgm2 2 × warm tst s Jadm kgm2 tst s J kgm2 LpfA, LWA, tolerance +3 dB(A) no-load tolerance +3 dB(A) no-load dB(A) dB(A) Terminal box Type 1.H1202-3AB14-2... 1240 1290 36.5 12.5 265 31.0 105 11.5 3.5 73 88 GT 640 1.H1202-3AB34-2... 1420 1470 27.0 9.5 340 24.5 130 9.0 4.4 73 88 1XB1 621 1.H1202-3AB54-2... 1600 1650 17.5 6.0 375 18.0 145 7.0 5.0 73 88 1XB1 621 1.H1202-3AB74-2... 1770 1820 15.5 5.5 425 17.0 175 7.0 5.8 73 88 1XB1 621 1.H1202-3BB54-2... 2200 2250 29.0 7.5 620 38.5 255 15.5 8.3 73 88.5 1XB1 621 1.H1202-3BB74-2... 2320 2380 21.5 5.5 600 29.0 255 12.0 8.9 73 88.5 1XB1 621 1.H1202-3AC14-3... 1270 1320 27.0 9.5 460 23.5 185 9.0 5.9 68 83 GT 640 1.H1202-3AC34-3... 1450 1500 25.5 9.0 540 22.0 210 8.0 7.2 68 83 GT 640 1.H1202-3AC54-3... 1630 1680 27.0 9.5 640 23.5 250 8.5 8.3 68 83 1XB1 621 1.H1202-3AC74-3... 1740 1790 20.5 7.5 755 18.5 300 7.0 9.1 68 83 1XB1 621 1.H1202-3BC54-3... 2190 2250 20.5 7.5 675 18.0 310 8.0 14.5 68 83.5 1XB1 621 1.H1202-3BC74-3... 2340 2390 20.5 7.5 715 18.0 330 8.0 16.0 68 83.5 1XB1 621 1.H1202-3AD14-4... 1270 1320 41.0 23.5 1030 45.5 675 28.0 5.9 72 82 GT 640 1.H1202-3AD34-4... 1450 1500 35.5 16.0 1150 37.0 550 16.5 7.2 72 82 GT 640 1.H1202-3AD54-4... 1630 1680 34.0 12.5 1250 34.0 495 12.5 8.3 72 82 1XB1 621 1.H1202-3AD74-4... 1740 1790 34.5 12.5 1345 34.0 535 12.5 9.1 72 82 1XB1 621 1.H1202-3BD54-4... 2190 2250 37.5 13.5 1020 36.0 450 14.0 14.5 72 87.5 1XB1 621 1.H1202-3BD74-4... 2340 2390 38.5 14.0 1125 37.0 510 15.0 16.0 72 87.5 1XB1 621 Siemens D 81.8 · 04/2014 6/27 6 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for mains-fed operation Line voltage 690 V, 50 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated Prated Frame Con- frated size nection kW hp Hz FS Trated 1LH1/1MH1 cast-iron series specially designed for mains-fed operation Effiηrated, ηrated, ηrated, cosϕra- Irated ciency 5/4 4/4 3/4 ted, 4/4 class Nm % % % ILR/ Irated TLR/ TB/ Trated Trated Article No. L without explosion protection M with explosion protection A • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) approx. 1500 rpm, 4-pole 285 382 315 Y 50 1831 IE3 95.1 96.0 96.1 0.82 305 7.2 1.7 2.7 1■H1203-3AB14-2■■■ 380 510 315 Y 50 2443 – 95.1 96.1 96.3 0.86 385 7.3 1.7 2.6 1■H1203-3AB34-2■■■ 430 577 315 Y 50 2764 – 95.2 96.2 96.3 0.87 430 7.5 1.8 2.6 1■H1203-3AB54-2■■■ 495 664 315 Y 50 3182 – 95.3 96.3 96.5 0.88 490 7.7 1.9 2.6 1■H1203-3AB74-2■■■ 555 744 355 Y 50 3565 – 95.5 96.6 96.8 0.87 550 6.4 1.5 2.2 1■H1203-3BB74-2■■■ approx. 1000 rpm, 6-pole 6 225 302 315 Y 50 2167 IE3 94.9 95.8 95.8 0.78 250 7.5 1.7 2.8 1■H1203-3AC14-3■■■ 310 416 315 Y 50 2988 IE3 94.9 95.9 96.0 0.80 340 7.6 1.7 2.7 1■H1203-3AC34-3■■■ 355 476 315 Y 50 3421 IE3 95.0 96.0 96.1 0.81 380 7.8 1.7 2.7 1■H1203-3AC54-3■■■ 405 543 315 Y 50 3905 – 95.1 96.1 96.2 0.83 425 7.5 1.6 2.6 1■H1203-3AC74-3■■■ 470 630 355 Y 50 4525 – 95.0 96.1 96.4 0.83 495 7.4 1.6 2.1 1■H1203-3BC54-3■■■ 510 684 355 Y 50 4910 – 95.1 96.2 96.4 0.84 530 7.4 1.6 2.1 1■H1203-3BC74-3■■■ For versions, see Article No. supplements and special versions 6/28 Siemens D 81.8 · 04/2014 1■H1203-3AC74-3■■■ © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for mains-fed operation Line voltage 690 V, 50 Hz Premium Efficiency Motor type mIM B3 mIM V1 Blocking time Admissible moment of inertia and start-up times when starting up the motor cold warm 3 × cold tBr tBr Jadm 2 × warm tst Jadm tst J LpfA, LWA, tolerance +3 dB(A) no-load tolerance +3 dB(A) no-load Terminal box kg kg s s kgm2 s kgm2 s kgm2 dB(A) dB(A) Type 1.H1203-3AB14-2... 1240 1290 22.5 9.5 280 21.5 130 9.5 3.5 73 88 GT 640 1.H1203-3AB34-2... 1420 1470 19.0 7.0 310 18.0 130 7.5 4.4 73 88 1XB1 621 1.H1203-3AB54-2... 1600 1650 17.5 6.0 370 18.0 150 7.0 5.0 73 88 1XB1 621 1.H1203-3AB74-2... 1770 1820 15.5 5.5 395 16.0 170 6.5 5.8 73 88 1XB1 621 1.H1203-3BB74-2... 2320 2380 21.5 6.5 605 29.5 325 15.5 8.9 73 88.5 1XB1 621 1.H1203-3AC14-3... 1270 1320 22.0 10.0 495 19.5 255 9.5 5.9 68 83 GT 640 1.H1203-3AC34-3... 1450 1500 20.0 7.0 565 17.0 230 6.5 7.2 68 83 1XB1 621 1.H1203-3AC54-3... 1630 1680 19.5 7.0 605 16.0 255 6.5 8.3 68 83 1XB1 621 1.H1203-3AC74-3... 1740 1790 21.0 7.5 740 18.5 295 7.0 9.1 68 83 1XB1 621 1.H1203-3BC54-3... 2190 2250 20.5 9.0 690 18.5 395 10.0 14.5 68 83.5 1XB1 621 1.H1203-3BC74-3... 2340 2390 20.5 9.0 735 18.5 405 10.0 16.0 68 83.5 1XB1 621 Siemens D 81.8 · 04/2014 6/29 6 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for mains-fed operation Line voltage 460 V, 60 Hz High Efficiency ■ Selection and ordering data Operating values at rated output Prated Prated Frame Con- frated size nection kW hp Hz FS Trated 1LH1/1MH1 cast-iron series specially designed for mains-fed operation Effiηrated, ηrated, ηrated, cosϕra- Irated ciency 5/4 4/4 3/4 ted, 4/4 class Nm % % % ILR/ Irated TLR/ TB/ Trated Trated Article No. L without explosion protection M with explosion protection A • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) approx. 1800 rpm, 4-pole 6 300 402 315 Δ 60 1608 IE2 94.8 95.8 96.0 0.87 450 5.9 1.2 2.0 1■H1202-3AB15-6■■■ 405 543 315 Δ 60 2169 – 95.2 96.1 96.3 0.88 600 6.5 1.4 2.2 1■H1202-3AB35-6■■■ 485 650 315 Δ 60 2593 – 95.6 95.9 96.4 0.88 720 7.7 1.7 2.6 1■H1202-3AB55-6■■■ 560 751 315 Δ 60 2994 – 95.7 95.9 96.6 0.89 820 7.9 1.8 2.6 1■H1202-3AB75-6■■■ 565 758 355 Δ 60 3024 – 95.4 96.4 96.6 0.88 840 5.7 1.2 2.0 1■H1202-3BB55-6■■■ 640 858 355 Δ 60 3423 – 95.7 96.6 96.7 0.88 940 6.3 1.4 2.2 1■H1202-3BB75-6■■■ approx. 1200 rpm, 6-pole 255 342 315 Δ 60 2049 IE2 94.8 95.7 95.9 0.83 405 6.9 1.3 2.2 1■H1202-3AC15-7■■■ 310 416 315 Δ 60 2488 IE2 95.1 95.7 96.1 0.84 485 7.1 1.3 2.3 1■H1202-3AC35-7■■■ 360 483 315 Δ 60 2890 IE2 95.1 95.7 96.2 0.86 550 6.9 1.2 2.2 1■H1202-3AC55-7■■■ 440 590 315 Δ 60 3528 – 95.5 95.7 96.3 0.84 690 7.9 1.5 2.6 1■H1202-3AC75-7■■■ 545 731 355 Δ 60 4369 – 95.2 96.2 96.3 0.85 840 7.4 1.5 2.0 1■H1202-3BC55-7■■■ 585 784 355 Δ 60 4693 – 95.3 96.3 96.4 0.85 900 7.4 1.5 2.0 1■H1202-3BC75-7■■■ approx. 900 rpm, 8-pole 225 302 315 Δ 60 2418 – 93.4 94.7 95.1 0.77 385 4.7 0.9 1.6 1■H1202-3AD15-8■■■ 285 382 315 Δ 60 3058 – 93.9 95.2 95.4 0.78 480 5.2 1.0 1.7 1■H1202-3AD35-8■■■ 335 449 315 Δ 60 3592 – 94.2 95.3 95.5 0.78 570 5.2 1.0 1.7 1■H1202-3AD55-8■■■ 370 496 315 Δ 60 3968 – 94.2 95.4 95.5 0.79 620 5.1 1.0 1.7 1■H1202-3AD75-8■■■ 425 570 355 Δ 60 4568 – 93.8 94.9 95.3 0.81 690 4.6 0.9 1.4 1■H1202-3BD55-8■■■ 470 630 355 Δ 60 5049 – 93.9 95.0 95.4 0.81 770 4.5 0.9 1.4 1■H1202-3BD75-8■■■ For versions, see Article No. supplements and special versions 6/30 Siemens D 81.8 · 04/2014 1■H1202-3AD75-8■■■ © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for mains-fed operation Line voltage 460 V, 60 Hz High Efficiency Motor type mIM B3 mIM V1 Blocking time Admissible moment of inertia and start-up times when starting up the motor cold warm 3 × cold tBr tBr Jadm 2 × warm tst Jadm tst J LpfA, LWA, tolerance +3 dB(A) no-load tolerance +3 dB(A) no-load Terminal box kg kg s s kgm2 s kgm2 s kgm2 dB(A) dB(A) Type 1.H1202-3AB15-6... 1240 1290 33.0 13.0 200 32.0 80 12.0 3.5 73 88 GT 640 1.H1202-3AB35-6... 1420 1470 22.0 8.5 255 25.0 95 9.0 4.4 73 88 1XB1 621 1.H1202-3AB55-6... 1600 1650 13.5 5.5 280 18.5 110 7.0 5.0 73 88 1XB1 631 1.H1202-3AB75-6... 1770 1820 12.0 4.5 320 17.5 130 7.0 5.8 73 88 1XB1 631 1.H1202-3BB55-6... 2200 2250 24.0 6.5 380 32.0 175 14.0 8.3 73 88.5 1XB1 631 1.H1202-3BB75-6... 2320 2380 17.0 4.5 360 24.0 165 10.5 8.9 73 88.5 1XB1 631 1.H1202-3AC15-7... 1270 1320 28.0 10.0 345 24.5 140 9.0 5.9 68 83 GT 640 1.H1202-3AC35-7... 1450 1500 26.5 10.0 415 23.0 170 9.0 7.2 68 83 GT 640 1.H1202-3AC55-7... 1630 1680 28.0 10.0 485 24.5 190 9.0 8.3 68 83 1XB1 621 1.H1202-3AC75-7... 1740 1790 21.5 7.5 570 19.0 225 7.0 9.1 68 83 1XB1 631 1.H1202-3BC55-7... 2190 2250 21.5 7.5 510 18.5 230 8.0 14.5 68 83.5 1XB1 631 1.H1202-3BC75-7... 2340 2390 21.5 7.5 540 18.5 245 8.0 16.0 68 83.5 1XB1 631 1.H1202-3AD15-8... 1270 1320 43.0 15.0 635 42.5 245 14.5 5.9 72 82 GT 640 1.H1202-3AD35-8... 1450 1500 37.0 13.5 790 36.5 315 13.5 7.2 72 82 GT 640 1.H1202-3AD55-8... 1630 1680 35.5 13.0 915 35.0 360 12.5 8.3 72 82 1XB1 621 1.H1202-3AD75-8... 1740 1790 36.0 12.5 980 34.5 375 12.0 9.1 72 82 1XB1 631 1.H1202-3BD55-8... 2190 2250 39.5 14.5 750 37.5 340 15.0 14.5 72 87.5 1XB1 631 1.H1202-3BD75-8... 2340 2390 40.0 14.5 810 37.5 365 15.0 16.0 72 87.5 1XB1 631 Siemens D 81.8 · 04/2014 6/31 6 © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for mains-fed operation Line voltage 460 V, 60 Hz Premium Efficiency ■ Selection and ordering data Operating values at rated output Prated Prated Frame Con- frated size nection kW hp Hz FS Trated 1LH1/1MH1 cast-iron series specially designed for mains-fed operation Effiηrated, ηrated, ηrated, cosϕra- Irated ciency 5/4 4/4 3/4 ted, 4/4 class Nm % % % ILR/ Irated TLR/ TB/ Trated Trated Article No. L without explosion protection M with explosion protection A • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B) approx. 1800 rpm, 4-pole 345 463 315 Δ 60 1845 IE3 95.3 96.2 96.3 0.84 540 6.9 1.4 2.5 1■H1203-3AB15-6■■■ 435 583 315 Δ 60 2327 – 95.5 96.4 96.5 0.86 660 7.3 1.6 2.5 1■H1203-3AB35-6■■■ 490 657 315 Δ 60 2620 – 95.6 96.5 96.6 0.87 730 7.6 1.7 2.5 1■H1203-3AB55-6■■■ 565 758 315 Δ 60 3021 – 95.8 96.6 96.7 0.88 830 7.8 1.7 2.5 1■H1203-3AB75-6■■■ 615 825 355 Δ 60 3287 – 95.9 96.8 97.0 0.87 920 6.5 1.4 2.2 1■H1203-3BB75-6■■■ approx. 1200 rpm, 6-pole 6 275 369 315 Δ 60 2207 IE3 95.1 96.0 96.1 0.80 450 7.6 1.5 2.5 1■H1203-3AC15-7■■■ 345 463 315 Δ 60 2766 IE3 95.4 96.3 96.3 0.81 560 7.7 1.6 2.7 1■H1203-3AC35-7■■■ 395 530 315 Δ 60 3167 – 95.5 96.4 96.4 0.82 630 7.9 1.6 2.7 1■H1203-3AC55-7■■■ 450 603 315 Δ 60 3610 – 95.6 96.4 96.5 0.84 700 7.7 1.5 2.5 1■H1203-3AC75-7■■■ 530 711 355 Δ 60 4251 – 95.5 96.5 96.6 0.84 820 7.6 1.5 2.0 1■H1203-3BC55-7■■■ 565 758 355 Δ 60 4530 – 95.6 96.6 96.7 0.85 860 7.7 1.5 2.1 1■H1203-3BC75-7■■■ For versions, see Article No. supplements and special versions 6/32 Siemens D 81.8 · 04/2014 1■H1203-3AC75-7■■■ © Siemens AG 2014 Water-cooled motors with water-jacket cooling 1LH1/1MH1 motors for mains-fed operation Line voltage 460 V, 60 Hz Premium Efficiency Motor type mIM B3 mIM V1 Blocking time Admissible moment of inertia and start-up times when starting up the motor cold warm 3 × cold tBr tBr Jadm 2 × warm tst Jadm tst J LpfA, LWA, tolerance +3 dB(A) no-load tolerance +3 dB(A) no-load Terminal box kg kg s s kgm2 s kgm2 s kgm2 dB(A) dB(A) Type 1.H1203-3AB15-6... 1240 1290 18.0 7.0 200 21.5 80 8.0 3.5 73 88 1XB1 621 1.H1203-3AB35-6... 1420 1470 15.0 6.0 235 18.5 95 7.0 4.4 73 88 1XB1 631 1.H1203-3AB55-6... 1600 1650 14.0 5.5 280 18.5 110 7.0 5.0 73 88 1XB1 631 1.H1203-3AB75-6... 1770 1820 12.0 4.5 295 16.5 125 6.5 5.8 73 88 1XB1 631 1.H1203-3BB75-6... 2320 2380 17.0 5.5 360 24.0 205 13.0 8.9 73 88.5 1XB1 631 1.H1203-3AC15-7... 1270 1320 23.0 8.0 350 19.5 140 7.5 5.9 68 83 GT 640 1.H1203-3AC35-7... 1450 1500 21.0 7.5 430 18.0 175 7.0 7.2 68 83 1XB1 621 1.H1203-3AC55-7... 1630 1680 20.0 7.0 455 16.5 190 6.5 8.3 68 83 1XB1 631 1.H1203-3AC75-7... 1740 1790 21.5 7.5 560 19.0 225 7.0 9.1 68 83 1XB1 631 1.H1203-3BC55-7... 2190 2250 21.5 9.0 520 19.0 285 10.0 14.5 68 83.5 1XB1 631 1.H1203-3BC75-7... 2340 2390 21.5 9.0 555 19.0 305 10.0 16.0 68 83.5 1XB1 631 Siemens D 81.8 · 04/2014 6/33 6 © Siemens AG 2014 Water-cooled motors with water-jacket cooling Dimensions 1LH1/1MH1 motors ■ Dimensional drawings IM B3 type of construction For terminal box dimensions, see Page 6/36. L LL BE HB' HK HC GA HD AC ØD F HB AG AD BC H HA EB DB G_D081_XX_00420 BA E 6 C B BB ØK AA Ø K' A AB IM B35 and IM V1 types of construction For flange dimensions, see Page 6/35 (Z = the number of retaining holes), For terminal box dimensions, see Page 6/36 L LL HC HB' HK HH T HD AG AD BE HB ZxS GA AC ØP ØN ØD F E M H HA EB DB G_D081_XX_00421 BA LA LE Frame No. of size poles Motor type 315 1.H12..-3A.1.-.... 1.H12..-3A.3.-.... 4, 6, 8 4, 6, 8 1.H12..-3A.5.-…. 1.H12..-3A.7.-….. Ø K' B BB D DB 560 120 680 630 630 180 780 180 315 28 AA AB AC B BA BB C 28 35 1280 85 M20 170 140 22 90 ● 560 120 680 630 630 180 780 200 315 28 28 35 1300 95 M24 170 140 25 100 H HA K K' L E EB F GA 560 120 680 630 835 180 985 180 315 28 28 35 1420 85 M20 170 140 22 90 ● 560 120 680 630 835 180 985 200 315 28 28 35 1440 95 M24 170 140 25 100 630 150 780 710 800 220 980 200 355 35 35 42 1530 95 M24 170 140 25 100 ● 630 150 780 710 800 220 980 224 355 28 28 35 1595 100 M24 210 180 28 106 ● Bearing design for increased cantilever forces, for type of construction IM B3 only. 6/34 AA A AB Dimension designation acc. to IEC A 1.H12..-3A.5.-.... 1.H12..-3A.7.-.... 355 C ØK Siemens D 81.8 · 04/2014 © Siemens AG 2014 Water-cooled motors with water-jacket cooling Dimensions Flanges G_D081_XX_00026 ■ Dimensional drawings (Z = the number of retaining holes) Flange with through holes Motor type Frame size No. of poles Type of construction Flange type Dimension designation acc. to IEC LA 1LH1/1MH1 315 355 4, 6 4, 6 IM B35, IM V1 IM B35, IM V1 LE M N P S T Z Flange 29 170 740 680 800 22 6 8 Flange (optional) 22 170 600 550 660 22 6 8 Flange 29 170 840 780 900 22 6 8 Flange (optional) 22 170 600 550 660 22 6 8 Siemens D 81.8 · 04/2014 6/35 6 © Siemens AG 2014 Water-cooled motors with water-jacket cooling Dimensions Terminal boxes ■ Dimensional drawings LL BE HB' HK HC AG1 IM B3 type of construction HD HB AG AD BC G_D081_XX_00426 HC HB' AG1 LL HH HK HD AG AD BE HB 6 IM B35 and IM V1 types of construction G_D081_XX_00427 Motor type Frame size No. of poles Terminal box Dimension designation acc. to IEC AD AG AG1 BC BE HB HB' HH HC HD HK LL 1LH1/ 1MH1 315 4, 6 1XB7 730 710 575 – 115 – 890 310 295 180 1025 255 345 1XB7 731 710 575 – 115 115 890 310 295 180 1025 255 345 1XB7 740 800 615 60 115 150 930 365 295 235 1110 340 425 GT640 655 555 – 115 110 870 225 295 155 970 170 310 1XB1 621 705 585 – 115 150 900 305 295 165 1020 250 330 1XB1 631 775 640 – 115 100 955 400 295 175 1090 320 555 1XB7 730 750 615 – 100 – 970 310 300 180 1105 255 345 1XB7 731 750 615 – 100 115 970 310 300 180 1105 255 345 1XB7 740 840 655 60 100 150 1010 365 300 235 1190 340 425 GT640 695 595 – 100 110 950 225 300 155 1050 170 310 1XB1 621 745 625 – 100 150 980 305 300 165 1100 250 330 1XB1 631 815 680 – 100 100 1035 400 300 175 1170 320 555 355 6/36 4, 6 Siemens D 81.8 · 04/2014 7 © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger 7/2 7/2 7/4 7/6 7/8 7/10 7/12 7/12 7/13 7/14 1LN1/1MN1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency Line voltage 500 V, 50 Hz High Efficiency Line voltage 690 V, 50 Hz High Efficiency Line voltage 460 V, 60 Hz High Efficiency Line voltage 575 V, 60 Hz High Efficiency Dimensions 1LN1/1MN1 motors Flanges Terminal boxes Siemens D 81.8 · 04/2014 © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger 1LN1/1MN1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency ■ Selection and ordering data 7 Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion 1LN1/1MN1 cast-iron series specially designed for converter-fed operation 3/4 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V 3000 rpm, 4-pole 350 469 315 Δ 101.0 1114 94.8 95.8 95.9 0.88 560 4.5 1.5 1■N1212-3AB11-1■■■ 1■N1212-3AB31-1■■■ 440 590 315 Δ 100.9 1402 95.2 96.1 96.2 0.89 700 4.8 1.6 490 657 315 Δ 100.8 1561 95.4 96.2 96.2 0.90 770 5.2 1.7 1■N1212-3AB51-1■■■ 570 764 315 Δ 100.8 1816 95.6 96.4 96.4 0.90 890 5.4 1.8 1■N1212-3AB71-1■■■ 1■N1212-3BB51-1■■■ 670 898 355 Δ 100.8 2133 95.5 96.4 96.4 0.88 1080 4.3 1.6 675 905 355 Δ 100.9 2149 95.3 96.4 96.4 0.88 1080 4.0 1.5 1■N1212-3BB71-1■■■ 1500 rpm, 4-pole 315 422 315 Δ 50.7 2006 94.0 95.2 95.7 0.88 510 5.6 2.0 1■N1212-3AB11-2■■■ 415 557 315 Δ 50.7 2643 94.5 95.7 96.1 0.89 660 6.3 2.2 1■N1212-3AB31-2■■■ 455 610 315 Δ 50.6 2898 94.7 95.8 96.1 0.90 720 6.4 2.3 1■N1212-3AB51-2■■■ 525 704 315 Δ 50.7 3343 94.7 95.8 96.2 0.90 830 6.3 2.2 1■N1212-3AB71-2■■■ 630 845 355 Δ 50.7 4012 94.6 95.9 96.3 0.89 1000 5.1 1.9 1■N1212-3BB51-2■■■ 715 959 355 Δ 50.6 4552 94.9 96.1 96.5 0.89 1140 5.5 2.1 1■N1212-3BB71-2■■■ 1000 rpm, 6-pole 285 382 315 Δ 50.7 2722 93.7 95.0 95.5 0.82 495 5.7 1.8 1■N1212-3AC11-3■■■ 345 463 315 Δ 50.7 3295 94.1 95.3 95.7 0.83 590 5.9 1.8 1■N1212-3AC31-3■■■ 395 530 315 Δ 50.7 3773 94.1 95.4 95.8 0.84 670 5.7 1.8 1■N1212-3AC51-3■■■ 1■N1212-3AC71-3■■■ 445 597 315 Δ 50.6 4250 94.4 95.5 95.9 0.84 750 6.1 1.7 540 724 355 Δ 50.5 5158 94.3 95.5 95.8 0.86 890 6.4 1.9 1■N1212-3BC51-3■■■ 615 825 355 Δ 50.5 5876 94.7 95.7 95.9 0.86 1020 7.1 1.7 1■N1212-3BC71-3■■■ 750 rpm, 6-pole 230 308 315 Δ 38.2 2930 92.3 93.8 94.6 0.81 410 5.4 1.8 1■N1212-3AC11-4■■■ 285 382 315 Δ 38.2 3629 92.7 94.2 94.9 0.83 495 5.4 1.8 1■N1212-3AC31-4■■■ 320 429 315 Δ 38.2 4076 92.7 94.3 95.0 0.85 540 5.2 1.7 1■N1212-3AC51-4■■■ 360 483 315 Δ 38.2 4586 92.8 94.4 95.1 0.85 610 5.2 1.6 1■N1212-3AC71-4■■■ 420 563 355 Δ 38.1 5350 92.8 94.3 95.0 0.87 700 5.6 1.8 1■N1212-3BC51-4■■■ 470 630 355 Δ 38.1 5986 93.1 94.6 95.1 0.88 770 5.9 1.7 1■N1212-3BC71-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V 3000 rpm, 4-pole 340 456 315 Δ 100.9 1082 94.9 95.8 95.9 0.88 610 4.5 1.5 1■N1222-3AB11-1■■■ 1■N1222-3AB31-1■■■ 440 590 315 Δ 100.9 1402 95.4 96.2 96.3 0.89 780 5.0 1.7 500 671 315 Δ 100.8 1592 95.6 96.3 96.3 0.90 880 5.5 1.8 1■N1222-3AB51-1■■■ 510 684 315 Δ 100.9 1624 95.3 96.2 96.3 0.90 890 4.8 1.6 1■N1222-3AB71-1■■■ 690 925 355 Δ 100.7 2198 95.7 96.5 96.5 0.89 1220 5.0 1.8 1■N1222-3BB51-1■■■ 700 939 355 Δ 100.8 2230 95.6 96.5 96.5 0.89 1240 4.6 1.6 1■N1222-3BB71-1■■■ 1500 rpm, 4-pole 330 443 315 Δ 50.7 2102 94.2 95.4 95.8 0.87 600 5.9 2.2 1■N1222-3AB11-2■■■ 405 543 315 Δ 50.6 2579 94.5 95.7 96.1 0.89 720 6.3 2.3 1■N1222-3AB31-2■■■ 460 617 315 Δ 50.6 2929 94.7 95.8 96.2 0.90 810 6.5 2.3 1■N1222-3AB51-2■■■ 535 717 315 Δ 50.6 3407 94.8 95.9 96.3 0.90 940 6.5 2.2 1■N1222-3AB71-2■■■ 645 865 355 Δ 50.7 4108 94.7 95.9 96.3 0.89 1140 5.2 2.0 1■N1222-3BB51-2■■■ 750 1006 355 Δ 50.6 4776 95.1 96.2 96.5 0.89 1340 5.7 2.1 1■N1222-3BB71-2■■■ 1000 rpm, 6-pole 280 375 315 Δ 50.7 2675 93.7 95.0 95.5 0.82 550 5.5 1.8 1■N1222-3AC11-3■■■ 345 463 315 Δ 50.6 3295 94.1 95.3 95.7 0.83 660 6.0 1.9 1■N1222-3AC31-3■■■ 400 536 315 Δ 50.6 3821 94.2 95.4 95.8 0.84 760 5.9 1.8 1■N1222-3AC51-3■■■ 1■N1222-3AC71-3■■■ 445 597 315 Δ 50.7 4251 94.3 95.5 95.9 0.85 830 5.8 1.7 550 738 355 Δ 50.5 5255 94.5 95.6 95.8 0.86 1020 6.9 1.9 1■N1222-3BC51-3■■■ 595 798 355 Δ 50.5 5685 94.6 95.7 95.9 0.87 1080 7.1 1.7 1■N1222-3BC71-3■■■ 750 rpm, 6-pole 235 315 315 Δ 38.2 2994 92.5 94.0 94.7 0.81 470 5.3 1.8 1■N1222-3AC11-4■■■ 285 382 315 Δ 38.1 3632 92.9 94.3 95.0 0.82 560 5.7 1.9 1■N1222-3AC31-4■■■ 325 436 315 Δ 38.2 4139 92.9 94.4 95.0 0.84 620 5.5 1.8 1■N1222-3AC51-4■■■ 355 476 315 Δ 38.2 4522 92.8 94.4 95.1 0.85 670 5.2 1.6 1■N1222-3AC71-4■■■ 420 563 355 Δ 38.1 5350 92.8 94.4 95.0 0.87 780 5.6 1.8 1■N1222-3BC51-4■■■ 475 637 355 Δ 38.1 6050 93.1 94.6 95.1 0.88 870 6.0 1.6 1■N1222-3BC71-4■■■ For versions, see Article No. supplements and special versions 1■N1222-3AC76-8■■■ Prated 7/2 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕrated, Irated ILR/ Irated T B/ Trated © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger 1LN1/1MN1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency Motor type mIM B3 mIM V1 J LpfA, LWA, Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 tolerance +3 dB(A) no-load Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.N1212-3AB11-1... 1.N1212-3AB31-1... 1.N1212-3AB51-1... 1.N1212-3AB71-1... 1.N1212-3BB51-1... 1.N1212-3BB71-1... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 6SL3710-7LE41-2AA3 590 725 820 960 1230 1230 1.N1212-3AB11-2... 1.N1212-3AB31-2... 1.N1212-3AB51-2... 1.N1212-3AB71-2... 1.N1212-3BB51-2... 1.N1212-3BB71-2... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 6SL3710-7LE41-2AA3 590 725 725 960 1230 1230 1.N1212-3AC11-3... 1.N1212-3AC31-3... 1.N1212-3AC51-3... 1.N1212-3AC71-3... 1.N1212-3BC51-3... 1.N1212-3BC71-3... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 590 590 725 820 960 1230 1.N1212-3AC11-4... 1.N1212-3AC31-4... 1.N1212-3AC51-4... 1.N1212-3AC71-4... 1.N1212-3BC51-4... 1.N1212-3BC71-4... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 477 590 590 725 725 820 1.N1222-3AB11-1... 1.N1222-3AB31-1... 1.N1222-3AB51-1... 1.N1222-3AB71-1... 1.N1222-3BB51-1... 1.N1222-3BB71-1... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3600 3600 3600 3600 3300 3300 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-4AA3 6SL3710-2GE41-4AA3 725 820 960 960 1340 1340 1.N1222-3AB11-2... 1.N1222-3AB31-2... 1.N1222-3AB51-2... 1.N1222-3AB71-2... 1.N1222-3BB51-2... 1.N1222-3BB71-2... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3000 3000 3000 3000 2600 2600 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-4AA3 6SL3710-2GE41-4AA3 725 725 820 960 1340 1340 1.N1222-3AC11-3... 1.N1222-3AC31-3... 1.N1222-3AC51-3... 1.N1222-3AC71-3... 1.N1222-3BC51-3... 1.N1222-3BC71-3... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-1AA3 590 725 820 960 1092 1092 1.N1222-3AC11-4... 1.N1222-3AC31-4... 1.N1222-3AC51-4... 1.N1222-3AC71-4... 1.N1222-3BC51-4... 1.N1222-3BC71-4... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 477 590 725 725 820 960 Siemens D 81.8 · 04/2014 7/3 7 © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger 1LN1/1MN1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency ■ Selection and ordering data 7 Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion 1LN1/1MN1 cast-iron series specially designed for converter-fed operation 3/4 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V 3000 rpm, 4-pole 330 443 315 Δ 100.8 1051 94.9 95.8 95.8 0.88 435 4.9 1.7 1■N1212-3AB12-1■■■ 1■N1212-3AB32-1■■■ 440 590 315 Δ 100.7 1401 95.5 96.2 96.2 0.90 560 5.8 1.9 485 650 315 Δ 100.7 1544 95.5 96.3 96.2 0.90 620 6.0 2.0 1■N1212-3AB52-1■■■ 500 671 315 Δ 100.9 1593 95.3 96.1 96.2 0.90 640 5.2 1.7 1■N1212-3AB72-1■■■ 1■N1212-3BB52-1■■■ 665 892 355 Δ 100.7 2118 95.5 96.4 96.4 0.89 860 4.9 1.7 680 912 355 Δ 100.8 2165 95.4 96.3 96.4 0.89 880 4.5 1.6 1■N1212-3BB72-1■■■ 1500 rpm, 4-pole 295 396 315 Δ 50.7 1879 93.9 95.1 95.6 0.88 390 5.9 2.1 1■N1212-3AB12-2■■■ 370 496 315 Δ 50.7 2357 94.3 95.5 95.9 0.89 485 6.2 2.2 1■N1212-3AB32-2■■■ 435 583 315 Δ 50.6 2770 94.6 95.7 96.1 0.90 560 6.8 2.4 1■N1212-3AB52-2■■■ 520 697 315 Δ 50.5 3311 95.0 96.0 96.2 0.89 680 7.5 2.2 1■N1212-3AB72-2■■■ 660 885 355 Δ 50.6 4203 94.8 95.9 96.3 0.89 860 5.8 2.2 1■N1212-3BB52-2■■■ 735 986 355 Δ 50.6 4680 95.0 96.1 96.4 0.89 950 6.2 2.1 1■N1212-3BB72-2■■■ 1000 rpm, 6-pole 270 362 315 Δ 50.6 2579 93.8 95.0 95.4 0.82 385 6.0 1.9 1■N1212-3AC12-3■■■ 320 429 315 Δ 50.6 3058 94.0 95.2 95.6 0.83 450 6.3 2.0 1■N1212-3AC32-3■■■ 360 483 315 Δ 50.6 3439 94.0 95.2 95.7 0.84 500 5.9 1.9 1■N1212-3AC52-3■■■ 1■N1212-3AC72-3■■■ 400 536 315 Δ 50.6 3821 94.1 95.3 95.8 0.85 550 6.1 1.9 500 671 355 Δ 50.5 4779 94.3 95.4 95.7 0.86 680 7.0 2.1 1■N1212-3BC52-3■■■ 565 758 355 Δ 50.5 5399 94.5 95.6 95.7 0.87 750 7.5 1.8 1■N1212-3BC72-3■■■ 750 rpm, 6-pole 215 288 315 Δ 38.1 2740 92.3 93.8 94.5 0.81 315 5.8 2.0 1■N1212-3AC12-4■■■ 260 349 315 Δ 38.1 3311 92.7 94.1 94.8 0.82 375 5.9 2.0 1■N1212-3AC32-4■■■ 285 382 315 Δ 38.1 3630 92.6 94.1 94.9 0.84 400 5.5 1.8 1■N1212-3AC52-4■■■ 320 429 315 Δ 38.1 4076 93.0 94.4 95.0 0.84 450 5.8 1.8 1■N1212-3AC72-4■■■ 405 543 355 Δ 38 5158 93.1 94.5 95.0 0.87 550 6.6 1.9 1■N1212-3BC52-4■■■ 420 563 355 Δ 38 5348 93.1 94.5 95.0 0.88 560 6.4 1.9 1■N1212-3BC72-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V 3000 rpm, 4-pole 360 483 315 Δ 100.9 1146 94.9 95.9 95.9 0.88 510 4.6 1.5 1■N1222-3AB12-1■■■ 1■N1222-3AB32-1■■■ 440 590 315 Δ 100.9 1402 95.2 96.1 96.2 0.89 620 4.8 1.6 490 657 315 Δ 100.9 1561 95.3 96.2 96.2 0.90 680 5.0 1.7 1■N1222-3AB52-1■■■ 560 751 315 Δ 100.9 1784 95.5 96.3 96.4 0.90 780 5.1 1.7 1■N1222-3AB72-1■■■ 650 872 355 Δ 100.9 2069 95.4 96.3 96.4 0.88 920 4.2 1.5 1■N1222-3BB52-1■■■ 745 999 355 Δ 100.7 2373 95.7 96.6 96.5 0.89 1040 4.8 1.7 1■N1222-3BB72-1■■■ 1500 rpm, 4-pole 315 422 315 Δ 50.8 2006 93.9 95.2 95.7 0.88 450 5.3 1.9 1■N1222-3AB12-2■■■ 425 570 315 Δ 50.6 2707 94.6 95.7 96.1 0.88 610 6.3 2.3 1■N1222-3AB32-2■■■ 470 630 315 Δ 50.6 2993 94.7 95.8 96.2 0.90 660 6.4 2.3 1■N1222-3AB52-2■■■ 515 691 315 Δ 50.6 3280 94.8 95.9 96.2 0.90 720 6.5 2.3 1■N1222-3AB72-2■■■ 705 945 355 Δ 50.6 4489 95.0 96.1 96.4 0.88 1000 5.8 2.2 1■N1222-3BB52-2■■■ 715 959 355 Δ 50.6 4553 94.9 96.0 96.4 0.89 1000 5.4 2.1 1■N1222-3BB72-2■■■ 1000 rpm, 6-pole 265 355 315 Δ 50.7 2531 93.7 95.0 95.5 0.82 410 5.5 1.8 1■N1222-3AC12-3■■■ 350 469 315 Δ 50.6 3343 94.2 95.3 95.7 0.83 530 6.0 1.9 1■N1222-3AC32-3■■■ 395 530 315 Δ 50.7 3773 94.1 95.4 95.8 0.84 590 5.8 1.8 1■N1222-3AC52-3■■■ 1■N1222-3AC72-3■■■ 445 597 315 Δ 50.6 4251 94.4 95.5 95.9 0.84 670 5.9 1.7 535 717 355 Δ 50.5 5111 94.2 95.4 95.7 0.87 780 6.3 1.9 1■N1222-3BC52-3■■■ 605 811 355 Δ 50.5 5778 94.5 95.6 95.9 0.87 870 6.9 1.7 1■N1222-3BC72-3■■■ 750 rpm, 6-pole 230 308 315 Δ 38.2 2931 92.2 93.8 94.6 0.81 365 5.2 1.8 1■N1222-3AC12-4■■■ 285 382 315 Δ 38.2 3629 92.7 94.2 94.9 0.83 440 5.4 1.8 1■N1222-3AC32-4■■■ 315 422 315 Δ 38.2 4013 92.5 94.1 94.9 0.85 475 5.1 1.7 1■N1222-3AC52-4■■■ 345 463 315 Δ 38.2 4395 92.6 94.2 95.0 0.85 520 5.0 1.7 1■N1222-3AC72-4■■■ 430 577 355 Δ 38.1 5477 93.0 94.4 95.0 0.87 630 5.8 1.8 1■N1222-3BC52-4■■■ 475 637 355 Δ 38.1 6051 93.1 94.6 95.1 0.88 690 5.9 1.6 1■N1222-3BC72-4■■■ For versions, see Article No. supplements and special versions 1■N1222-3AC76-8■■■ Prated 7/4 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕrated, Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger 1LN1/1MN1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.N1212-3AB12-1... 1.N1212-3AB32-1... 1.N1212-3AB52-1... 1.N1212-3AB72-1... 1.N1212-3BB52-1... 1.N1212-3BB72-1... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-8AA3 6SL3710-7LG38-8AA3 452 560 710 710 880 880 1.N1212-3AB12-2... 1.N1212-3AB32-2... 1.N1212-3AB52-2... 1.N1212-3AB72-2... 1.N1212-3BB52-2... 1.N1212-3BB72-2... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-8AA3 6SL3710-7LG41-0AA3 400 560 560 710 880 1000 1.N1212-3AC12-3... 1.N1212-3AC32-3... 1.N1212-3AC52-3... 1.N1212-3AC72-3... 1.N1212-3BC52-3... 1.N1212-3BC72-3... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 400 452 560 560 710 790 1.N1212-3AC12-4... 1.N1212-3AC32-4... 1.N1212-3AC52-4... 1.N1212-3AC72-4... 1.N1212-3BC52-4... 1.N1212-3BC72-4... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 320 400 400 452 560 560 1.N1222-3AB12-1... 1.N1222-3AB32-1... 1.N1222-3AB52-1... 1.N1222-3AB72-1... 1.N1222-3BB52-1... 1.N1222-3BB72-1... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 590 725 725 820 960 1092 1.N1222-3AB12-2... 1.N1222-3AB32-2... 1.N1222-3AB52-2... 1.N1222-3AB72-2... 1.N1222-3BB52-2... 1.N1222-3BB72-2... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-1AA3 477 725 725 725 1092 1092 1.N1222-3AC12-3... 1.N1222-3AC32-3... 1.N1222-3AC52-3... 1.N1222-3AC72-3... 1.N1222-3BC52-3... 1.N1222-3BC72-3... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 477 590 590 725 820 960 1.N1222-3AC12-4... 1.N1222-3AC32-4... 1.N1222-3AC52-4... 1.N1222-3AC72-4... 1.N1222-3BC52-4... 1.N1222-3BC72-4... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 370 477 477 590 725 725 Siemens D 81.8 · 04/2014 7 7/5 © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger 1LN1/1MN1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency ■ Selection and ordering data 7 Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion 1LN1/1MN1 cast-iron series specially designed for converter-fed operation 3/4 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V 3000 rpm, 4-pole 330 443 315 Δ 100.9 1051 94.8 95.7 95.8 0.88 310 4.8 1.6 1■N1212-3AB13-1■■■ 1■N1212-3AB33-1■■■ 435 583 315 Δ 100.8 1385 95.3 96.1 96.2 0.90 400 5.5 1.8 495 664 315 Δ 100.7 1576 95.6 96.3 96.2 0.90 450 6.2 2.0 1■N1212-3AB53-1■■■ 560 751 315 Δ 100.7 1783 95.6 96.4 96.3 0.91 500 6.0 1.9 1■N1212-3AB73-1■■■ 1■N1212-3BB53-1■■■ 675 905 355 Δ 100.8 2151 95.4 96.3 96.4 0.88 630 4.6 1.7 685 919 355 Δ 100.8 2181 95.3 96.3 96.4 0.88 640 4.2 1.5 1■N1212-3BB73-1■■■ 1500 rpm, 4-pole 295 396 315 Δ 50.6 1879 94.0 95.2 95.7 0.88 280 6.1 2.2 1■N1212-3AB13-2■■■ 385 516 315 Δ 50.6 2452 94.5 95.6 96.0 0.88 360 6.8 2.4 1■N1212-3AB33-2■■■ 445 597 315 Δ 50.6 2834 94.7 95.8 96.1 0.89 415 7.0 2.5 1■N1212-3AB53-2■■■ 505 677 315 Δ 50.6 3216 94.9 95.9 96.2 0.90 465 7.3 2.3 1■N1212-3AB73-2■■■ 650 872 355 Δ 50.6 4139 94.7 95.9 96.3 0.89 600 5.5 2.1 1■N1212-3BB53-2■■■ 705 945 355 Δ 50.6 4489 94.8 95.9 96.3 0.89 650 5.6 2.1 1■N1212-3BB73-2■■■ 1000 rpm, 6-pole 245 329 315 Y 50.6 2341 93.9 95.0 95.4 0.82 250 6.4 2.0 1■N1212-3AC13-3■■■ 320 429 315 Y 50.6 3056 93.9 95.1 95.6 0.83 320 6.2 1.9 1■N1212-3AC33-3■■■ 365 489 315 Y 50.6 3487 94.0 95.2 95.7 0.84 360 6.0 1.9 1■N1212-3AC53-3■■■ 1■N1212-3AC73-3■■■ 410 550 315 Δ 50.6 3917 94.2 95.4 95.8 0.85 400 6.2 1.9 500 671 355 Δ 50.5 4778 94.2 95.3 95.6 0.86 480 6.9 2.1 1■N1212-3BC53-3■■■ 570 764 355 Δ 50.5 5447 94.5 95.6 95.7 0.87 540 7.5 1.8 1■N1212-3BC73-3■■■ 750 rpm, 6-pole 210 282 315 Y 38.1 2675 92.2 93.7 94.4 0.81 220 5.7 1.9 1■N1212-3AC13-4■■■ 265 355 315 Y 38.1 3375 92.7 94.2 94.8 0.83 270 5.7 1.9 1■N1212-3AC33-4■■■ 295 396 315 Δ 38.1 3757 92.6 94.1 94.9 0.84 295 5.5 1.8 1■N1212-3AC53-4■■■ 325 436 315 Δ 38.1 4139 92.9 94.3 95.0 0.85 320 5.6 1.8 1■N1212-3AC73-4■■■ 400 536 355 Y 38 5094 93.0 94.4 94.9 0.87 385 6.5 1.9 1■N1212-3BC53-4■■■ 455 610 355 Δ 38 5795 93.2 94.6 95.1 0.87 435 6.6 1.7 1■N1212-3BC73-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V 3000 rpm, 4-pole 335 449 315 Δ 100.8 1067 94.9 95.8 95.8 0.88 350 4.9 1.7 1■N1222-3AB13-1■■■ 1■N1222-3AB33-1■■■ 420 563 315 Δ 100.8 1338 95.3 96.1 96.2 0.90 425 5.4 1.8 485 650 315 Δ 100.7 1544 95.6 96.3 96.2 0.90 490 6.2 2.1 1■N1222-3AB53-1■■■ 550 738 315 Δ 100.7 1751 95.7 96.4 96.3 0.91 550 6.1 2.0 1■N1222-3AB73-1■■■ 655 878 355 Δ 100.7 2087 95.5 96.4 96.4 0.89 670 4.8 1.7 1■N1222-3BB53-1■■■ 670 898 355 Δ 100.8 2133 95.4 96.3 96.4 0.88 690 4.4 1.6 1■N1222-3BB73-1■■■ 1500 rpm, 4-pole 300 402 315 Δ 50.7 1911 94.1 95.3 95.7 0.88 315 6.0 2.2 1■N1222-3AB13-2■■■ 380 510 315 Δ 50.6 2420 94.4 95.5 95.9 0.89 390 6.4 2.3 1■N1222-3AB33-2■■■ 425 570 315 Δ 50.6 2707 94.6 95.7 96.0 0.90 430 6.9 2.4 1■N1222-3AB53-2■■■ 505 677 315 Δ 50.6 3216 94.8 95.9 96.2 0.90 510 7.2 2.3 1■N1222-3AB73-2■■■ 675 905 355 Δ 50.6 4299 94.9 96.0 96.4 0.88 700 6.0 2.3 1■N1222-3BB53-2■■■ 690 925 355 Δ 50.6 4393 94.8 95.9 96.4 0.89 710 5.6 2.1 1■N1222-3BB73-2■■■ 1000 rpm, 6-pole 245 329 315 Y 50.6 2342 93.8 95.0 95.4 0.82 275 6.4 2.0 1■N1222-3AC13-3■■■ 315 422 315 Δ 50.6 3010 94.0 95.2 95.6 0.83 350 6.3 2.0 1■N1222-3AC33-3■■■ 365 489 315 Δ 50.6 3486 94.2 95.3 95.7 0.84 400 6.1 1.9 1■N1222-3AC53-3■■■ 1■N1222-3AC73-3■■■ 410 550 315 Δ 50.6 3918 94.3 95.4 95.8 0.84 450 6.4 1.9 490 657 355 Δ 50.5 4682 94.2 95.4 95.7 0.87 520 6.9 2.1 1■N1222-3BC53-3■■■ 555 744 355 Δ 50.4 5303 94.5 95.6 95.8 0.87 580 7.7 1.9 1■N1222-3BC73-3■■■ 750 rpm, 6-pole 205 275 315 Y 38.2 2610 92.1 93.7 94.4 0.82 235 5.6 1.9 1■N1222-3AC13-4■■■ 270 362 315 Δ 38.1 3440 92.9 94.3 94.9 0.82 305 6.0 2.0 1■N1222-3AC33-4■■■ 300 402 315 Δ 38.1 3821 92.7 94.2 94.9 0.84 330 5.7 1.8 1■N1222-3AC53-4■■■ 320 429 315 Δ 38.1 4076 92.7 94.2 94.9 0.85 350 5.5 1.8 1■N1222-3AC73-4■■■ 405 543 355 Δ 38 5157 93.1 94.5 95.0 0.87 430 6.6 1.9 1■N1222-3BC53-4■■■ 435 583 355 Δ 38 5540 93.1 94.5 95.0 0.87 465 6.4 1.8 1■N1222-3BC73-4■■■ For versions, see Article No. supplements and special versions 1■N1222-3AC76-8■■■ Prated 7/6 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕrated, Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger 1LN1/1MN1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.N1212-3AB13-1... 1.N1212-3AB33-1... 1.N1212-3AB53-1... 1.N1212-3AB73-1... 1.N1212-3BB53-1... 1.N1212-3BB73-1... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 320 400 452 560 710 710 1.N1212-3AB13-2... 1.N1212-3AB33-2... 1.N1212-3AB53-2... 1.N1212-3AB73-2... 1.N1212-3BB53-2... 1.N1212-3BB73-2... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 320 400 452 560 710 710 1.N1212-3AC13-3... 1.N1212-3AC33-3... 1.N1212-3AC53-3... 1.N1212-3AC73-3... 1.N1212-3BC53-3... 1.N1212-3BC73-3... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 250 320 400 400 560 560 1.N1212-3AC13-4... 1.N1212-3AC33-4... 1.N1212-3AC53-4... 1.N1212-3AC73-4... 1.N1212-3BC53-4... 1.N1212-3BC73-4... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 250 320 320 320 400 452 1.N1222-3AB13-1... 1.N1222-3AB33-1... 1.N1222-3AB53-1... 1.N1222-3AB73-1... 1.N1222-3BB53-1... 1.N1222-3BB73-1... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH35-8AA3 6SL3710-1GH37-4AA3 6SL3710-1GH37-4AA3 400 452 560 560 710 710 1.N1222-3AB13-2... 1.N1222-3AB33-2... 1.N1222-3AB53-2... 1.N1222-3AB73-2... 1.N1222-3BB53-2... 1.N1222-3BB73-2... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH37-4AA3 6SL3710-1GH37-4AA3 320 400 452 560 710 710 1.N1222-3AC13-3... 1.N1222-3AC33-3... 1.N1222-3AC53-3... 1.N1222-3AC73-3... 1.N1222-3BC53-3... 1.N1222-3BC73-3... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH37-4AA3 320 400 400 452 560 710 1.N1222-3AC13-4... 1.N1222-3AC33-4... 1.N1222-3AC53-4... 1.N1222-3AC73-4... 1.N1222-3BC53-4... 1.N1222-3BC73-4... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-1GH32-6AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 250 320 400 400 452 560 Siemens D 81.8 · 04/2014 7 7/7 © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger 1LN1/1MN1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency ■ Selection and ordering data 7 Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion 1LN1/1MN1 cast-iron series specially designed for converter-fed operation 3/4 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V 3600 rpm, 4-pole 415 557 315 Δ 120.8 1102 95.3 95.9 95.8 0.88 590 5.0 1.7 1■N1212-3AB15-5■■■ 525 704 315 Δ 120.8 1393 95.7 96.3 96.1 0.89 740 5.7 1.9 1■N1212-3AB35-5■■■ 535 717 315 Δ 120.9 1420 95.4 96.1 96.0 0.89 750 5.0 1.6 1■N1212-3AB55-5■■■ 620 831 315 Δ 120.8 1646 95.7 96.3 96.2 0.90 860 5.4 1.7 1■N1212-3AB75-5■■■ 3000 rpm, 4-pole 655 878 355 Δ 100.9 2085 95.3 96.3 96.4 0.88 930 4.2 1.5 1■N1212-3BB55-1■■■ 1■N1212-3BB75-1■■■ 745 999 355 Δ 100.7 2373 95.7 96.6 96.5 0.89 1040 4.8 1.7 1800 rpm, 4-pole 370 496 315 Δ 60.7 1964 94.9 95.9 96.1 0.87 530 6.1 2.2 1■N1212-3AB15-6■■■ 1■N1212-3AB35-6■■■ 455 610 315 Δ 60.7 2415 95.0 96.0 96.3 0.89 640 6.2 2.2 1■N1212-3AB55-6■■■ 500 671 315 Δ 60.7 2653 95.1 96.2 96.4 0.90 690 6.4 2.2 635 852 315 Δ 60.6 3369 95.6 96.5 96.7 0.90 880 7.7 2.2 1■N1212-3AB75-6■■■ 785 1053 355 Δ 60.6 4166 95.4 96.5 96.7 0.89 1100 5.9 2.2 1■N1212-3BB55-6■■■ 1■N1212-3BB75-6■■■ 800 1073 355 Δ 60.7 4245 95.3 96.4 96.7 0.89 1120 5.4 2.0 1200 rpm, 6-pole 310 416 315 Δ 60.7 2468 94.3 95.5 95.9 0.82 475 5.7 1.7 1■N1212-3AC15-7■■■ 375 503 315 Δ 60.7 2986 94.6 95.7 96.1 0.84 560 5.9 1.8 1■N1212-3AC35-7■■■ 455 610 315 Δ 60.6 3622 95.0 96.0 96.2 0.84 680 6.3 1.9 1■N1212-3AC55-7■■■ 1■N1212-3AC75-7■■■ 485 650 315 Δ 60.6 3861 94.9 96.0 96.2 0.85 710 6.2 1.9 620 831 355 Δ 60.5 4935 95.1 96.0 96.1 0.86 900 7.2 2.0 1■N1212-3BC55-7■■■ 1■N1212-3BC75-7■■■ 670 898 355 Δ 60.5 5333 95.1 96.1 96.2 0.87 960 7.2 1.9 900 rpm, 6-pole 270 362 315 Δ 45.7 2865 93.4 94.7 95.3 0.82 420 5.6 1.8 1■N1212-3AC15-8■■■ 1■N1212-3AC35-8■■■ 340 456 315 Δ 45.6 3609 93.9 95.1 95.5 0.82 520 6.2 2.0 365 489 315 Δ 45.7 3875 93.7 95.0 95.5 0.85 540 5.6 1.8 1■N1212-3AC55-8■■■ 1■N1212-3AC75-8■■■ 400 536 315 Δ 45.6 4246 93.9 95.1 95.6 0.85 600 5.7 1.7 485 650 355 Δ 45.6 5148 93.7 95.1 95.5 0.87 710 6.0 1.9 1■N1212-3BC55-8■■■ 545 731 355 Δ 45.5 5785 94.0 95.2 95.6 0.87 790 6.3 1.7 1■N1212-3BC75-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V 3600 rpm, 4-pole 425 570 315 Δ 120.8 1128 95.4 96.0 95.8 0.88 660 5.2 1.7 1■N1222-3AB15-5■■■ 495 664 315 Δ 120.9 1314 95.5 96.2 96.1 0.89 760 5.0 1.7 1■N1222-3AB35-5■■■ 560 751 315 Δ 120.8 1486 95.6 96.2 96.0 0.90 850 5.6 1.8 1■N1222-3AB55-5■■■ 1■N1222-3AB75-5■■■ 650 872 315 Δ 120.7 1725 95.9 96.5 96.2 0.91 970 6.3 2.0 3000 rpm, 4-pole 680 912 355 Δ 100.8 2166 95.6 96.5 96.5 0.88 1060 4.6 1.7 1■N1222-3BB55-1■■■ 690 925 355 Δ 100.8 2197 95.5 96.4 96.5 0.88 1060 4.3 1.5 1■N1222-3BB75-1■■■ 1800 rpm, 4-pole 365 489 315 Δ 60.7 1937 94.9 95.9 96.1 0.87 570 6.2 2.2 1■N1222-3AB15-6■■■ 455 610 315 Δ 60.6 2415 95.1 96.1 96.3 0.89 700 6.4 2.3 1■N1222-3AB35-6■■■ 515 691 315 Δ 60.6 2733 95.2 96.2 96.5 0.90 780 6.6 2.3 1■N1222-3AB55-6■■■ 595 798 315 Δ 60.6 3157 95.4 96.3 96.6 0.91 890 6.8 2.3 1■N1222-3AB75-6■■■ 710 952 355 Δ 60.6 3768 95.3 96.3 96.6 0.89 1080 5.4 2.0 1■N1222-3BB55-6■■■ 840 1126 355 Δ 60.6 4458 95.5 96.5 96.8 0.89 1280 5.9 2.2 1■N1222-3BB75-6■■■ 1200 rpm, 6-pole 330 443 315 Δ 60.6 2627 94.7 95.7 96.0 0.82 550 6.2 1.9 1■N1222-3AC15-7■■■ 385 516 315 Δ 60.6 3065 94.8 95.8 96.1 0.83 640 6.1 1.9 1■N1222-3AC35-7■■■ 440 590 315 Δ 60.6 3503 94.9 95.9 96.2 0.84 720 6.2 1.9 1■N1222-3AC55-7■■■ 495 664 315 Δ 60.7 3941 94.9 96.0 96.3 0.85 800 5.9 1.8 1■N1222-3AC75-7■■■ 605 811 355 Δ 60.5 4816 95.1 96.0 96.1 0.86 960 7.2 2.1 1■N1222-3BC55-7■■■ 1■N1222-3BC75-7■■■ 670 898 355 Δ 60.5 5332 95.1 96.1 96.2 0.87 1060 7.1 1.9 900 rpm, 6-pole 270 362 315 Δ 45.7 2867 93.4 94.7 95.2 0.81 460 5.9 1.9 1■N1222-3AC15-8■■■ 325 436 315 Δ 45.6 3449 93.7 95.0 95.5 0.82 550 5.8 1.9 1■N1222-3AC35-8■■■ 365 489 315 Δ 45.7 3874 93.7 95.0 95.6 0.84 600 5.7 1.8 1■N1222-3AC55-8■■■ 400 536 315 Δ 45.7 4246 93.7 95.1 95.6 0.85 650 5.4 1.7 1■N1222-3AC75-8■■■ 490 657 355 Δ 45.5 5200 93.9 95.2 95.5 0.87 780 6.4 1.9 1■N1222-3BC55-8■■■ 560 751 355 Δ 45.5 5942 94.2 95.4 95.7 0.87 890 6.7 1.7 1■N1222-3BC75-8■■■ For versions, see Article No. supplements and special versions 1■N1222-3AC76-8■■■ Prated 7/8 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕrated, Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger 1LN1/1MN1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency Motor type mIM B3 mIM V1 J LpfA, LWA, Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 tolerance +3 dB(A) no-load Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.N1212-3AB15-5... 1.N1212-3AB35-5... 1.N1212-3AB55-5... 1.N1212-3AB75-5... 1540 1730 1910 2070 1590 1780 1960 2120 3.3 4.2 4.8 5.7 79 79 79 79 95.5 95.5 95.5 95.5 3600 3600 3600 3600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE38-4AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 590 820 820 960 1.N1212-3BB55-1... 1.N1212-3BB75-1... 2740 2860 2790 2920 8.0 8.7 79 79 96 96 3300 3300 1XB7 740 1XB7 740 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 960 1230 1.N1212-3AB15-6... 1.N1212-3AB35-6... 1.N1212-3AB55-6... 1.N1212-3AB75-6... 1.N1212-3BB55-6... 1.N1212-3BB75-6... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 6SL3710-7LE41-2AA3 590 725 725 960 1230 1230 1.N1212-3AC15-7... 1.N1212-3AC35-7... 1.N1212-3AC55-7... 1.N1212-3AC75-7... 1.N1212-3BC55-7... 1.N1212-3BC75-7... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-0AA3 477 590 725 725 960 960 1.N1212-3AC15-8... 1.N1212-3AC35-8... 1.N1212-3AC55-8... 1.N1212-3AC75-8... 1.N1212-3BC55-8... 1.N1212-3BC75-8... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 477 590 590 725 725 820 1.N1222-3AB15-5... 1.N1222-3AB35-5... 1.N1222-3AB55-5... 1.N1222-3AB75-5... 1540 1730 1910 2070 1590 1780 1960 2120 3.3 4.2 4.8 5.7 79 79 79 79 95.5 95.5 95.5 95.5 3600 3600 3600 3600 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 725 820 960 1092 1.N1222-3BB55-1... 1.N1222-3BB75-1... 2740 2860 2790 2920 8.0 8.7 79 79 96 96 3300 3300 2 x 1XB7 740 6SL3710-2GE41-1AA3 2 x 1XB7 740 6SL3710-2GE41-1AA3 1092 1092 1.N1222-3AB15-6... 1.N1222-3AB35-6... 1.N1222-3AB55-6... 1.N1222-3AB75-6... 1.N1222-3BB55-6... 1.N1222-3BB75-6... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-4AA3 590 725 820 960 1092 1340 1.N1222-3AC15-7... 1.N1222-3AC35-7... 1.N1222-3AC55-7... 1.N1222-3AC75-7... 1.N1222-3BC55-7... 1.N1222-3BC75-7... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 590 725 725 820 960 1092 1.N1222-3AC15-8... 1.N1222-3AC35-8... 1.N1222-3AC55-8... 1.N1222-3AC75-8... 1.N1222-3BC55-8... 1.N1222-3BC75-8... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 477 590 725 725 820 960 Siemens D 81.8 · 04/2014 7 7/9 © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger 1LN1/1MN1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency ■ Selection and ordering data 7 Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion 1LN1/1MN1 cast-iron series specially designed for converter-fed operation 3/4 4/4 Article No. L without explosion protection kW hp FS Hz Nm % % % A M with explosion protection • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V 3600 rpm, 4-pole 385 516 315 Δ 120.9 1022 95.0 95.7 95.6 0.88 435 4.8 1.6 1■N1212-3AB16-5■■■ 505 677 315 Δ 120.7 1340 95.6 96.2 96.0 0.89 560 5.8 1.9 1■N1212-3AB36-5■■■ 555 744 315 Δ 120.7 1473 95.6 96.2 95.9 0.90 610 6.1 2.0 1■N1212-3AB56-5■■■ 635 852 315 Δ 120.7 1685 95.8 96.4 96.1 0.91 690 6.3 2.0 1■N1212-3AB76-5■■■ 3000 rpm, 4-pole 630 845 355 Δ 100.8 2006 95.2 96.2 96.3 0.88 700 4.2 1.5 1■N1212-3BB56-1■■■ 1■N1212-3BB76-1■■■ 705 945 355 Δ 100.8 2246 95.4 96.4 96.4 0.89 780 4.5 1.6 1800 rpm, 4-pole 330 443 315 Δ 60.6 1752 94.6 95.7 96.0 0.88 370 6.2 2.2 1■N1212-3AB16-6■■■ 1■N1212-3AB36-6■■■ 440 590 315 Δ 60.6 2335 95.2 96.1 96.3 0.89 485 7.3 2.6 1■N1212-3AB56-6■■■ 480 644 315 Δ 60.6 2547 95.2 96.2 96.4 0.90 520 7.3 2.5 590 791 315 Δ 60.5 3131 95.6 96.4 96.6 0.90 640 8.1 2.4 1■N1212-3AB76-6■■■ 740 992 355 Δ 60.6 3927 95.3 96.4 96.6 0.89 820 6.0 2.3 1■N1212-3BB56-6■■■ 1■N1212-3BB76-6■■■ 820 1100 355 Δ 60.5 4351 95.5 96.5 96.7 0.89 900 6.6 2.3 1200 rpm, 6-pole 300 402 315 Δ 60.6 2388 94.4 95.5 95.8 0.82 365 6.3 1.9 1■N1212-3AC16-7■■■ 360 483 315 Δ 60.6 2867 94.7 95.7 96.0 0.83 430 6.6 2.0 1■N1212-3AC36-7■■■ 405 543 315 Δ 60.6 3225 94.7 95.8 96.1 0.84 475 6.3 1.9 1■N1212-3AC56-7■■■ 1■N1212-3AC76-7■■■ 445 597 315 Δ 60.6 3544 94.9 95.9 96.1 0.85 520 6.5 2.0 585 784 355 Δ 60.4 4658 95.1 96.0 96.0 0.86 670 8.1 2.1 1■N1212-3BC56-7■■■ 1■N1212-3BC76-7■■■ 630 845 355 Δ 60.4 5017 95.1 96.0 96.1 0.87 710 7.9 2.0 900 rpm, 6-pole 240 322 315 Y 45.6 2549 93.2 94.5 95.0 0.81 295 6.0 1.9 1■N1212-3AC16-8■■■ 1■N1212-3AC36-8■■■ 315 422 315 Δ 45.6 3345 93.9 95.0 95.4 0.82 385 6.4 2.1 345 463 315 Δ 45.6 3664 93.7 95.0 95.5 0.84 410 6.0 1.9 1■N1212-3AC56-8■■■ 1■N1212-3AC76-8■■■ 380 510 315 Δ 45.6 4035 94.0 95.2 95.6 0.84 450 6.5 1.8 465 624 355 Δ 45.5 4935 93.9 95.1 95.4 0.87 530 6.9 2.0 1■N1212-3BC56-8■■■ 515 691 355 Δ 45.5 5466 94.0 95.2 95.5 0.87 590 6.8 1.8 1■N1212-3BC76-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V 3600 rpm, 4-pole 405 543 315 Δ 120.8 1075 95.3 95.9 95.7 0.88 500 5.6 1.8 1■N1222-3AB16-5■■■ 495 664 315 Δ 120.7 1314 95.6 96.2 96.0 0.90 600 6.1 2.0 1■N1222-3AB36-5■■■ 545 731 315 Δ 120.7 1446 95.7 96.2 95.9 0.90 660 6.6 2.2 1■N1222-3AB56-5■■■ 1■N1222-3AB76-5■■■ 580 778 315 Δ 120.8 1540 95.5 96.2 96.0 0.90 700 5.5 1.8 3000 rpm, 4-pole 620 831 355 Δ 100.8 1974 95.3 96.3 96.3 0.88 770 4.4 1.6 1■N1222-3BB56-1■■■ 700 939 355 Δ 100.7 2230 95.6 96.4 96.4 0.89 860 4.9 1.7 1■N1222-3BB76-1■■■ 1800 rpm, 4-pole 320 429 315 Δ 60.7 1699 94.6 95.6 96.0 0.88 400 5.9 2.1 1■N1222-3AB16-6■■■ 430 577 315 Δ 60.6 2282 95.1 96.1 96.3 0.89 530 7.1 2.5 1■N1222-3AB36-6■■■ 475 637 315 Δ 60.6 2521 95.2 96.2 96.4 0.90 580 7.1 2.5 1■N1222-3AB56-6■■■ 585 784 315 Δ 60.5 3104 95.6 96.5 96.6 0.89 720 8.2 2.4 1■N1222-3AB76-6■■■ 740 992 355 Δ 60.6 3927 95.4 96.4 96.6 0.89 910 6.2 2.3 1■N1222-3BB56-6■■■ 755 1012 355 Δ 60.6 4007 95.3 96.3 96.6 0.89 920 5.7 2.1 1■N1222-3BB76-6■■■ 1200 rpm, 6-pole 280 375 315 Δ 60.7 2229 94.1 95.3 95.7 0.83 370 6.0 1.8 1■N1222-3AC16-7■■■ 355 476 315 Δ 60.6 2828 94.7 95.7 96.0 0.83 470 6.6 2.0 1■N1222-3AC36-7■■■ 400 536 315 Δ 60.6 3185 94.7 95.8 96.1 0.84 520 6.4 1.9 1■N1222-3AC56-7■■■ 450 603 315 Δ 60.6 3584 94.9 95.9 96.2 0.85 580 6.7 2.0 1■N1222-3AC76-7■■■ 560 751 355 Δ 60.4 4459 95.0 95.9 96.0 0.86 710 7.8 2.2 1■N1222-3BC56-7■■■ 1■N1222-3BC76-7■■■ 625 838 355 Δ 60.4 4976 95.2 96.1 96.0 0.86 790 8.6 2.0 900 rpm, 6-pole 245 329 315 Δ 45.6 2602 93.4 94.6 95.1 0.80 340 6.3 2.1 1■N1222-3AC16-8■■■ 305 409 315 Δ 45.5 3239 93.8 95.0 95.3 0.81 415 6.7 2.2 1■N1222-3AC36-8■■■ 340 456 315 Δ 45.6 3610 93.8 95.1 95.5 0.83 450 6.4 2.0 1■N1222-3AC56-8■■■ 380 510 315 Δ 45.6 4035 93.9 95.1 95.5 0.84 500 6.3 1.8 1■N1222-3AC76-8■■■ 455 610 355 Δ 45.5 4828 93.9 95.1 95.5 0.87 580 6.8 2.1 1■N1222-3BC56-8■■■ 505 677 355 Δ 45.5 5359 94.0 95.2 95.5 0.87 640 7.0 1.8 1■N1222-3BC76-8■■■ For versions, see Article No. supplements and special versions 1■N1222-3AC76-8■■■ Prated 7/10 Prated Siemens D 81.8 · 04/2014 ηrated, cosϕrated, Irated ILR/ Irated TB/ Trated © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger 1LN1/1MN1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1.N1212-3AB16-5... 1.N1212-3AB36-5... 1.N1212-3AB56-5... 1.N1212-3AB76-5... 1540 1730 1910 2070 1590 1780 1960 2120 3.3 4.2 4.8 5.7 79 79 79 79 95.5 95.5 95.5 95.5 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 452 560 710 710 1.N1212-3BB56-1... 1.N1212-3BB76-1... 2740 2860 2790 2920 8.0 8.7 79 79 96 96 3300 3300 1XB7 740 1XB7 740 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 710 790 1.N1212-3AB16-6... 1.N1212-3AB36-6... 1.N1212-3AB56-6... 1.N1212-3AB76-6... 1.N1212-3BB56-6... 1.N1212-3BB76-6... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-8AA3 6SL3710-7LG41-0AA3 400 560 560 710 880 1000 1.N1212-3AC16-7... 1.N1212-3AC36-7... 1.N1212-3AC56-7... 1.N1212-3AC76-7... 1.N1212-3BC56-7... 1.N1212-3BC76-7... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 400 452 560 560 710 710 1.N1212-3AC16-8... 1.N1212-3AC36-8... 1.N1212-3AC56-8... 1.N1212-3AC76-8... 1.N1212-3BC56-8... 1.N1212-3BC76-8... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 320 400 452 452 560 710 1.N1222-3AB16-5... 1.N1222-3AB36-5... 1.N1222-3AB56-5... 1.N1222-3AB76-5... 1540 1730 1910 2070 1590 1780 1960 2120 3.3 4.2 4.8 5.7 79 79 79 79 95.5 95.5 95.5 95.5 3600 3600 3600 3600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 560 710 710 710 1.N1222-3BB56-1... 1.N1222-3BB76-1... 2740 2860 2790 2920 8.0 8.7 79 79 96 96 3300 3300 1XB7 740 1XB7 740 6SL3710-1GF38-1AA3 6SL3710-2GF41-1AA3 790 1036 1.N1222-3AB16-6... 1.N1222-3AB36-6... 1.N1222-3AB56-6... 1.N1222-3AB76-6... 1.N1222-3BB56-6... 1.N1222-3BB76-6... 1540 1730 1910 2070 2740 2860 1590 1780 1960 2120 2790 2920 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GF34-1AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF38-1AA3 6SL3710-2GF41-1AA3 6SL3710-2GF41-1AA3 400 560 710 790 1036 1036 1.N1222-3AC16-7... 1.N1222-3AC36-7... 1.N1222-3AC56-7... 1.N1222-3AC76-7... 1.N1222-3BC56-7... 1.N1222-3BC76-7... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GF34-1AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 6SL3710-1GF38-1AA3 400 560 560 710 710 790 1.N1222-3AC16-8... 1.N1222-3AC36-8... 1.N1222-3AC56-8... 1.N1222-3AC76-8... 1.N1222-3BC56-8... 1.N1222-3BC76-8... 1570 1750 1940 2050 2730 2880 1620 1800 1990 2100 2790 2930 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 95.5 95.5 95.5 95.5 96 96 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 400 452 452 560 710 710 Siemens D 81.8 · 04/2014 7 7/11 © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger Dimensions 1LN1/1MN1 motors ■ Dimensional drawings IM B3 type of construction For terminal box dimensions, see Page 7/14. L AC AD AG HK HB' BE LL HC ØD F EB BC H HA GA DB G_D081_XX_00422 BA E B BB Ø K' ØK AA A AB IM B35, IM V1 types of construction For flange dimensions, see Page 7/13 (Z = the number of retaining holes), For terminal box dimensions, see Page 7/14 L HH AD AG AC T HC M HB' H HA EB DB G_D081_XX_00423 BA LA LE Motor type 315 1.N12..-3A.1.-.... 1.N12..-3A.3.-.... 1.N12..-3A.5.-…. 1.N12..-3A.7.-…. Ø K' B BB AA AB AC B BA BB C 7/12 D DB 35 1785 85 M20 170 140 22 90 ● 560 120 680 1230 630 180 780 200 315 28 28 35 1805 95 M24 170 140 25 100 560 120 680 1230 835 180 985 180 315 28 28 35 1925 85 M20 170 140 22 90 ● 560 120 680 1230 835 180 985 200 315 28 28 35 1945 95 M24 170 140 25 100 630 150 780 1470 800 220 980 200 355 35 35 42 2080 95 M24 170 140 22 100 ● 630 150 780 1470 800 220 980 224 355 35 35 42 2145 100 M24 210 180 28 106 Siemens D 81.8 · 04/2014 HA K L 1) 28 With IM V1 type of construction, dimension L may increase due to a protective cover for the fan motor H K' 560 120 680 1230 630 180 780 180 315 28 ● Bearing design for increased cantilever forces, for type of construction IM B3 only. 1) AA A AB Dimension designation acc. to IEC A 1.N12..-3A.5.-.... 1.N12..-3A.7.-.... 4, 6 ØK C Frame No. of size poles 4, 6 BE LL ØP ØN ØD GA 355 HK ZxS E F 7 C E EB F GA © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger Dimensions Flanges G_D081_XX_00026 ■ Dimensional drawings (Z = the number of retaining holes) Flange with through holes Motor type Frame size No. of poles Type of construction Flange type Dimension designation acc. to IEC LA 1LN1/1MN1 315 355 4, 6 4, 6 IM B35, IM V1 IM B35, IM V1 LE M N P S T Z 8 Flange 29 170 740 680 800 22 6 Flange (optional) 22 170 600 550 660 22 6 8 Flange 29 170 840 780 900 22 6 8 Flange (optional) 22 170 600 550 660 22 6 8 7 Siemens D 81.8 · 04/2014 7/13 © Siemens AG 2014 Water-cooled motors with air-to-water heat exchanger Dimensions Terminal boxes ■ Dimensional drawings IM B3 type of construction BE LL HK AG1 G_D081_XX_00429 BC HC AG AD HB' IM B35, IM V1 types of construction BE LL HK AG1 7 HC HB' G_D081_XX_00430 AG AD HH Motor type Frame size No. of poles Terminal box Dimension designation acc. to IEC AD AG AG1 BC BE HB' HH HC HK LL 1LN1/ 1MN1 315 4, 6 1XB7 730 705 570 – 115 – 310 295 180 255 345 1XB7 731 705 570 – 115 115 310 295 180 255 345 1XB7 740 785 610 60 115 150 365 295 235 335 425 GT640 620 520 – 115 110 225 295 155 170 310 1XB1 621 700 580 – 115 150 305 295 165 250 330 1XB1 631 770 635 – 115 100 400 295 175 320 555 1XB7 730 750 615 – 100 – 310 300 180 255 345 1XB7 731 750 615 – 100 115 310 300 180 255 345 1XB7 740 830 655 60 100 150 365 300 235 335 425 GT640 665 565 – 100 110 225 300 155 170 310 1XB1 621 745 625 – 100 150 305 300 165 250 330 1XB1 631 815 680 – 100 100 400 300 175 320 555 355 7/14 4, 6 Siemens D 81.8 · 04/2014 8 © Siemens AG 2014 Self-ventilated motors – open version 8/2 8/2 8/4 8/6 8/8 8/10 8/12 8/12 8/13 8/14 1LL1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency Line voltage 500 V, 50 Hz High Efficiency Line voltage 690 V, 50 Hz High Efficiency Line voltage 460 V, 60 Hz High Efficiency Line voltage 575 V, 60 Hz High Efficiency Dimensions 1LL1 motors Flanges Terminal boxes Siemens D 81.8 · 04/2014 © Siemens AG 2014 Self-ventilated motors — open version 1LL1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency ■ Selection and ordering data Prated 8 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated TB/ Trated 1LL1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V 3000 rpm, 4-pole 330 443 315 Δ 100.9 1051 94.9 95.7 95.7 0.88 530 4.7 1.6 1LL1212-3AB11-1■■■ 415 557 315 Δ 100.8 1322 95.3 96.1 96.0 0.89 660 5.1 1.7 1LL1212-3AB31-1■■■ 1LL1212-3AB51-1■■■ 470 630 315 Δ 100.8 1497 95.5 96.3 96.2 0.90 740 5.4 1.8 545 731 315 Δ 100.8 1736 95.7 96.4 96.4 0.91 840 5.8 1.9 1LL1212-3AB71-1■■■ 670 898 355 Δ 100.8 2133 94.6 95.3 95.0 0.88 1080 4.3 1.6 1LL1212-3BB51-1■■■ 1LL1212-3BB71-1■■■ 675 905 355 Δ 100.9 2149 94.5 95.2 95.0 0.88 1100 4.0 1.5 1500 rpm, 4-pole 290 389 315 Δ 50.7 1847 94.0 95.1 95.3 0.88 470 6.0 2.2 1LL1212-3AB11-2■■■ 1LL1212-3AB31-2■■■ 420 563 315 Δ 50.7 2675 94.3 95.3 95.6 0.89 670 6.2 2.2 455 610 315 Δ 50.6 2898 94.4 95.5 95.8 0.90 720 6.4 2.3 1LL1212-3AB51-2■■■ 530 711 315 Δ 50.7 3375 94.5 95.6 95.9 0.90 840 6.2 2.2 1LL1212-3AB71-2■■■ 645 865 355 Δ 50.7 4108 94.3 95.5 95.9 0.89 1040 4.9 1.9 1LL1212-3BB51-2■■■ 735 986 355 Δ 50.6 4680 94.6 95.8 96.1 0.89 1180 5.3 2.0 1LL1212-3BB71-2■■■ 1000 rpm, 6-pole 265 355 315 Δ 50.6 2531 93.9 95.0 95.3 0.82 460 6.2 1.9 1LL1212-3AC11-3■■■ 1LL1212-3AC31-3■■■ 330 443 315 Δ 50.6 3152 94.1 95.2 95.6 0.83 570 6.1 1.9 380 510 315 Δ 50.6 3630 94.2 95.3 95.7 0.84 640 6.0 1.9 1LL1212-3AC51-3■■■ 425 570 315 Δ 50.6 4061 94.5 95.5 95.8 0.84 720 6.4 1.8 1LL1212-3AC71-3■■■ 1LL1212-3BC51-3■■■ 520 697 355 Δ 50.5 4967 94.3 95.4 95.6 0.86 860 6.7 2.0 595 798 355 Δ 50.5 5685 94.6 95.6 95.7 0.86 980 7.4 1.7 1LL1212-3BC71-3■■■ 750 rpm, 6-pole 205 275 315 Δ 38.1 2611 92.8 94.1 94.6 0.81 365 6.1 2.0 1LL1212-3AC11-4■■■ 255 342 315 Δ 38.1 3249 93.2 94.5 95.0 0.82 445 6.1 2.0 1LL1212-3AC31-4■■■ 290 389 315 Δ 38.1 3693 93.2 94.5 95.1 0.84 495 5.7 1.9 1LL1212-3AC51-4■■■ 325 436 315 Δ 38.1 4139 93.3 94.7 95.2 0.85 550 5.7 1.8 1LL1212-3AC71-4■■■ 375 503 355 Δ 38 4776 93.3 94.6 95.0 0.87 620 6.3 2.1 1LL1212-3BC51-4■■■ 425 570 355 Δ 38 5412 93.5 94.7 95.2 0.87 700 6.4 1.8 1LL1212-3BC71-4■■■ • Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G120P, SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V 3000 rpm, 4-pole 320 429 315 Δ 100.9 1020 94.9 95.7 95.6 0.88 580 4.7 1.6 1LL1222-3AB11-1■■■ 1LL1222-3AB31-1■■■ 410 550 315 Δ 100.8 1306 95.4 96.1 96.1 0.90 720 5.4 1.8 475 637 315 Δ 100.7 1513 95.6 96.3 96.3 0.90 830 5.9 1.9 1LL1222-3AB51-1■■■ 490 657 315 Δ 100.9 1561 95.4 96.2 96.3 0.90 860 5.0 1.7 1LL1222-3AB71-1■■■ 1LL1222-3BB51-1■■■ 690 925 355 Δ 100.7 2198 94.9 95.5 95.1 0.89 1240 4.9 1.8 700 939 355 Δ 100.8 2230 94.8 95.4 95.1 0.89 1260 4.5 1.6 1LL1222-3BB71-1■■■ 1500 rpm, 4-pole 320 429 315 Δ 50.7 2038 94.0 95.1 95.3 0.87 590 6.0 2.2 1LL1222-3AB11-2■■■ 415 557 315 Δ 50.7 2643 94.2 95.3 95.6 0.89 740 6.1 2.2 1LL1222-3AB31-2■■■ 465 624 315 Δ 50.7 2961 94.4 95.5 95.8 0.90 820 6.4 2.2 1LL1222-3AB51-2■■■ 540 724 315 Δ 50.7 3439 94.6 95.6 96.0 0.90 950 6.4 2.2 1LL1222-3AB71-2■■■ 655 878 355 Δ 50.7 4171 94.4 95.6 95.9 0.89 1160 5.1 1.9 1LL1222-3BB51-2■■■ 765 1026 355 Δ 50.6 4871 94.8 95.9 96.1 0.89 1360 5.7 2.0 1LL1222-3BB71-2■■■ 1000 rpm, 6-pole 260 349 315 Δ 50.6 2483 93.8 95.0 95.3 0.82 510 6.0 1.9 1LL1222-3AC11-3■■■ 335 449 315 Δ 50.6 3199 94.1 95.2 95.6 0.83 640 6.1 1.9 1LL1222-3AC31-3■■■ 380 510 315 Δ 50.6 3630 94.3 95.4 95.7 0.84 720 6.2 1.9 1LL1222-3AC51-3■■■ 425 570 315 Δ 50.6 4060 94.4 95.5 95.8 0.85 800 6.0 1.8 1LL1222-3AC71-3■■■ 530 711 355 Δ 50.5 5065 94.5 95.5 95.6 0.86 980 7.2 2.0 1LL1222-3BC51-3■■■ 585 784 355 Δ 50.5 5591 94.6 95.6 95.7 0.87 1060 7.2 1.8 1LL1222-3BC71-3■■■ 750 rpm, 6-pole 210 282 315 Δ 38.1 2676 93.0 94.3 94.8 0.81 420 6.0 2.0 1LL1222-3AC11-4■■■ 260 349 315 Δ 38.1 3314 93.2 94.5 95.0 0.82 510 6.3 2.1 1LL1222-3AC31-4■■■ 290 389 315 Δ 38.1 3695 93.4 94.6 95.1 0.83 560 6.1 2.0 1LL1222-3AC51-4■■■ 320 429 315 Δ 38.1 4076 93.3 94.6 95.2 0.85 600 5.9 1.8 1LL1222-3AC71-4■■■ 380 510 355 Δ 38 4839 93.2 94.6 95.0 0.87 700 6.3 2.0 1LL1222-3BC51-4■■■ 430 577 355 Δ 38 5476 93.5 94.7 95.1 0.87 790 6.6 1.8 1LL1222-3BC71-4■■■ For versions, see Article No. supplements and special versions 1LL1222-3AC71-4■■■ 8/2 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Self-ventilated motors — open version 1LL1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency Motor type mIM B3 mIM V1 J LpfA, LWA, Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 tolerance +3 dB(A) no-load Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LL1212-3AB11-1... 1LL1212-3AB31-1... 1LL1212-3AB51-1... 1LL1212-3AB71-1... 1LL1212-3BB51-1... 1LL1212-3BB71-1... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 6SL3710-7LE41-2AA3 590 725 820 960 1230 1230 1LL1212-3AB11-2... 1LL1212-3AB31-2... 1LL1212-3AB51-2... 1LL1212-3AB71-2... 1LL1212-3BB51-2... 1LL1212-3BB71-2... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 6SL3710-7LE41-2AA3 477 725 725 960 1230 1230 1LL1212-3AC11-3... 1LL1212-3AC31-3... 1LL1212-3AC51-3... 1LL1212-3AC71-3... 1LL1212-3BC51-3... 1LL1212-3BC71-3... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 477 590 725 725 960 1230 1LL1212-3AC11-4... 1LL1212-3AC31-4... 1LL1212-3AC51-4... 1LL1212-3AC71-4... 1LL1212-3BC51-4... 1LL1212-3BC71-4... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LE33-8AA3 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 370 477 590 590 725 725 1LL1222-3AB11-1... 1LL1222-3AB31-1... 1LL1222-3AB51-1... 1LL1222-3AB71-1... 1LL1222-3BB51-1... 1LL1222-3BB71-1... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3370-1PE36-6AA0 6SL3710-1GE37-5AA3 6SL3710-1GE41-0AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-4AA3 6SL3710-2GE41-4AA3 640 725 960 960 1340 1340 1LL1222-3AB11-2... 1LL1222-3AB31-2... 1LL1222-3AB51-2... 1LL1222-3AB71-2... 1LL1222-3BB51-2... 1LL1222-3BB71-2... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3370-1PE36-6AA0 6SL3710-1GE38-4AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-4AA3 6SL3710-2GE41-6AA3 640 820 820 960 1340 1516 1LL1222-3AC11-3... 1LL1222-3AC31-3... 1LL1222-3AC51-3... 1LL1222-3AC71-3... 1LL1222-3BC51-3... 1LL1222-3BC71-3... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-1PE35-8AA0 6SL3370-1PE36-6AA0 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-1AA3 570 640 725 820 1092 1092 1LL1222-3AC11-4... 1LL1222-3AC31-4... 1LL1222-3AC51-4... 1LL1222-3AC71-4... 1LL1222-3BC51-4... 1LL1222-3BC71-4... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1PE34-6AA0 6SL3710-1PE35-8AA0 6SL3710-1PE35-8AA0 6SL3370-1PE36-6AA0 6SL3710-1PE37-4AA0 6SL3710-1GE38-4AA3 450 570 570 640 710 820 Siemens D 81.8 · 04/2014 8/3 8 © Siemens AG 2014 Self-ventilated motors — open version 1LL1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency ■ Selection and ordering data Prated 8 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated TB/ Trated 1LL1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V 3000 rpm, 4-pole 305 409 315 Δ 100.8 971 94.9 95.6 95.5 0.89 400 5.3 1.8 1LL1212-3AB12-1■■■ 410 550 315 Δ 100.7 1305 95.5 96.1 96.0 0.90 530 6.1 2.0 1LL1212-3AB32-1■■■ 1LL1212-3AB52-1■■■ 455 610 315 Δ 100.7 1449 95.6 96.3 96.1 0.90 580 6.5 2.1 480 644 315 Δ 100.8 1529 95.4 96.2 96.2 0.90 620 5.3 1.8 1LL1212-3AB72-1■■■ 670 898 355 Δ 100.7 2135 94.6 95.3 94.9 0.89 880 4.8 1.7 1LL1212-3BB52-1■■■ 1LL1212-3BB72-1■■■ 680 912 355 Δ 100.8 2165 94.5 95.3 95.0 0.88 900 4.4 1.6 1500 rpm, 4-pole 275 369 315 Δ 50.6 1752 93.8 95.1 95.1 0.88 365 6.3 2.3 1LL1212-3AB12-2■■■ 1LL1212-3AB32-2■■■ 375 503 315 Δ 50.7 2388 94.0 95.1 95.4 0.89 490 6.1 2.2 440 590 315 Δ 50.6 2802 94.4 95.4 95.7 0.90 570 6.7 2.4 1LL1212-3AB52-2■■■ 530 711 315 Δ 50.6 3375 94.7 95.7 95.9 0.90 680 7.5 2.2 1LL1212-3AB72-2■■■ 655 878 355 Δ 50.6 4172 94.6 95.7 95.9 0.89 850 5.8 2.2 1LL1212-3BB52-2■■■ 730 979 355 Δ 50.5 4649 94.8 95.8 96.1 0.89 950 6.2 2.1 1LL1212-3BB72-2■■■ 1000 rpm, 6-pole 250 335 315 Δ 50.6 2389 93.9 95.0 95.3 0.82 355 6.5 2.1 1LL1212-3AC12-3■■■ 1LL1212-3AC32-3■■■ 305 409 315 Δ 50.6 2914 94.1 95.2 95.4 0.83 430 6.6 2.1 345 463 315 Δ 50.6 3297 94.0 95.2 95.5 0.84 480 6.2 1.9 1LL1212-3AC52-3■■■ 385 516 315 Δ 50.6 3679 94.2 95.3 95.6 0.85 530 6.3 2.0 1LL1212-3AC72-3■■■ 1LL1212-3BC52-3■■■ 485 650 355 Δ 50.5 4635 94.2 95.3 95.4 0.86 660 7.2 2.1 545 731 355 Δ 50.4 5208 94.5 95.5 95.6 0.87 730 7.7 1.9 1LL1212-3BC72-3■■■ 750 rpm, 6-pole 190 255 315 Δ 38 2420 92.8 94.1 94.5 0.80 280 6.5 2.2 1LL1212-3AC12-4■■■ 235 315 315 Δ 38 2993 93.0 94.4 94.8 0.82 335 6.6 2.2 1LL1212-3AC32-4■■■ 260 349 315 Δ 38.1 3314 93.0 94.4 94.9 0.84 365 6.1 2.0 1LL1212-3AC52-4■■■ 295 396 315 Δ 38.1 3759 93.3 94.6 95.1 0.84 410 6.4 2.0 1LL1212-3AC72-4■■■ 365 489 355 Δ 37.9 4650 93.4 94.6 95.0 0.86 500 7.2 2.1 1LL1212-3BC52-4■■■ 390 523 355 Δ 38 4966 93.3 94.6 95.0 0.87 530 6.8 2.0 1LL1212-3BC72-4■■■ • Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V 3000 rpm, 4-pole 330 443 315 Δ 100.8 1051 95.0 95.8 95.7 0.88 470 5.0 1.7 1LL1222-3AB12-1■■■ 1LL1222-3AB32-1■■■ 415 557 315 Δ 100.8 1322 95.3 96.1 96.0 0.89 580 5.1 1.7 465 624 315 Δ 100.8 1481 95.4 96.2 96.2 0.90 650 5.3 1.8 1LL1222-3AB52-1■■■ 535 717 315 Δ 100.8 1704 95.6 96.4 96.4 0.90 740 5.4 1.8 1LL1222-3AB72-1■■■ 1LL1222-3BB52-1■■■ 655 878 355 Δ 100.9 2085 94.4 95.2 94.9 0.88 940 4.1 1.5 745 999 355 Δ 100.8 2373 94.9 95.6 95.2 0.89 1060 4.7 1.7 1LL1222-3BB72-1■■■ 1500 rpm, 4-pole 285 382 315 Δ 50.7 1815 93.9 95.1 95.3 0.88 410 5.9 2.1 1LL1222-3AB12-2■■■ 425 570 315 Δ 50.6 2707 94.4 95.4 95.7 0.88 610 6.3 2.3 1LL1222-3AB32-2■■■ 475 637 315 Δ 50.7 3025 94.5 95.5 95.8 0.90 660 6.4 2.2 1LL1222-3AB52-2■■■ 530 711 315 Δ 50.7 3375 94.5 95.6 95.9 0.90 740 6.3 2.2 1LL1222-3AB72-2■■■ 720 966 355 Δ 50.6 4585 94.7 95.8 96.1 0.88 1020 5.7 2.2 1LL1222-3BB52-2■■■ 735 986 355 Δ 50.7 4681 94.5 95.7 96.1 0.89 1040 5.2 2.0 1LL1222-3BB72-2■■■ 1000 rpm, 6-pole 245 329 315 Δ 50.6 2340 93.8 95.0 95.3 0.82 380 6.0 1.9 1LL1222-3AC12-3■■■ 335 449 315 Δ 50.6 3200 94.2 95.3 95.6 0.83 510 6.2 2.0 1LL1222-3AC32-3■■■ 380 510 315 Δ 50.6 3630 94.2 95.3 95.7 0.84 570 6.0 1.9 1LL1222-3AC52-3■■■ 425 570 315 Δ 50.6 4061 94.4 95.5 95.8 0.84 640 6.2 1.8 1LL1222-3AC72-3■■■ 515 691 355 Δ 50.5 4919 94.2 95.3 95.6 0.86 760 6.5 2.0 1LL1222-3BC52-3■■■ 590 791 355 Δ 50.5 5638 94.5 95.5 95.7 0.87 850 7.0 1.8 1LL1222-3BC72-3■■■ 750 rpm, 6-pole 205 275 315 Δ 38.1 2611 92.7 94.1 94.7 0.81 325 5.9 2.0 1LL1222-3AC12-4■■■ 255 342 315 Δ 38.1 3249 93.2 94.5 95.0 0.82 395 6.0 2.0 1LL1222-3AC32-4■■■ 285 382 315 Δ 38.1 3630 93.0 94.4 95.0 0.84 430 5.6 1.8 1LL1222-3AC52-4■■■ 310 416 315 Δ 38.1 3948 93.2 94.5 95.1 0.85 465 5.6 1.8 1LL1222-3AC72-4■■■ 390 523 355 Δ 38 4966 93.3 94.6 95.1 0.87 570 6.4 2.0 1LL1222-3BC52-4■■■ 425 570 355 Δ 38 5412 93.5 94.8 95.2 0.87 620 6.6 1.8 1LL1222-3BC72-4■■■ For versions, see Article No. supplements and special versions 1LL1222-3AC72-4■■■ 8/4 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Self-ventilated motors — open version 1LL1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency Motor type mIM B3 mIM V1 J LpfA, LWA, Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 tolerance +3 dB(A) no-load Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LL1212-3AB12-1... 1LL1212-3AB32-1... 1LL1212-3AB52-1... 1LL1212-3AB72-1... 1LL1212-3BB52-1... 1LL1212-3BB72-1... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-8AA3 6SL3710-7LG41-0AA3 400 560 710 710 880 1000 1LL1212-3AB12-2... 1LL1212-3AB32-2... 1LL1212-3AB52-2... 1LL1212-3AB72-2... 1LL1212-3BB52-2... 1LL1212-3BB72-2... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-8AA3 6SL3710-7LG41-0AA3 400 560 710 710 880 1000 1LL1212-3AC12-3... 1LL1212-3AC32-3... 1LL1212-3AC52-3... 1LL1212-3AC72-3... 1LL1212-3BC52-3... 1LL1212-3BC72-3... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 400 452 560 560 710 790 1LL1212-3AC12-4... 1LL1212-3AC32-4... 1LL1212-3AC52-4... 1LL1212-3AC72-4... 1LL1212-3BC52-4... 1LL1212-3BC72-4... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 320 400 400 452 560 560 1LL1222-3AB12-1... 1LL1222-3AB32-1... 1LL1222-3AB52-1... 1LL1222-3AB72-1... 1LL1222-3BB52-1... 1LL1222-3BB72-1... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 477 590 725 820 960 1092 1LL1222-3AB12-2... 1LL1222-3AB32-2... 1LL1222-3AB52-2... 1LL1222-3AB72-2... 1LL1222-3BB52-2... 1LL1222-3BB72-2... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-1AA3 477 725 725 820 1092 1092 1LL1222-3AC12-3... 1LL1222-3AC32-3... 1LL1222-3AC52-3... 1LL1222-3AC72-3... 1LL1222-3BC52-3... 1LL1222-3BC72-3... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 477 590 590 725 820 960 1LL1222-3AC12-4... 1LL1222-3AC32-4... 1LL1222-3AC52-4... 1LL1222-3AC72-4... 1LL1222-3BC52-4... 1LL1222-3BC72-4... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 370 477 477 477 590 725 Siemens D 81.8 · 04/2014 8 8/5 © Siemens AG 2014 Self-ventilated motors — open version 1LL1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency ■ Selection and ordering data Prated 8 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated TB/ Trated 1LL1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V 3000 rpm, 4-pole 310 416 315 Δ 100.8 988 94.8 95.6 95.5 0.88 290 5.1 1.7 1LL1212-3AB13-1■■■ 410 550 315 Δ 100.7 1306 95.3 96.1 96.0 0.90 375 5.8 1.9 1LL1212-3AB33-1■■■ 1LL1212-3AB53-1■■■ 475 637 315 Δ 100.7 1512 95.6 96.3 96.2 0.90 435 6.4 2.1 530 711 315 Δ 100.7 1688 95.7 96.4 96.3 0.91 480 6.3 2.0 1LL1212-3AB73-1■■■ 675 905 355 Δ 100.8 2149 94.6 95.2 94.9 0.88 640 4.5 1.6 1LL1212-3BB53-1■■■ 1LL1212-3BB73-1■■■ 690 925 355 Δ 100.9 2197 94.4 95.2 95.0 0.88 650 4.2 1.5 1500 rpm, 4-pole 280 375 315 Δ 50.6 1783 93.8 95.1 95.1 0.87 270 6.3 2.3 1LL1212-3AB13-2■■■ 1LL1212-3AB33-2■■■ 390 523 315 Δ 50.6 2484 94.2 95.3 95.5 0.89 365 6.7 2.4 450 603 315 Δ 50.6 2866 94.5 95.5 95.8 0.89 420 6.9 2.5 1LL1212-3AB53-2■■■ 515 691 315 Δ 50.6 3280 94.6 95.6 95.9 0.90 475 7.2 2.3 1LL1212-3AB73-2■■■ 645 865 355 Δ 50.6 4107 94.5 95.6 95.9 0.89 600 5.5 2.1 1LL1212-3BB53-2■■■ 700 939 355 Δ 50.6 4458 94.6 95.7 96.0 0.89 650 5.6 2.1 1LL1212-3BB73-2■■■ 1000 rpm, 6-pole 230 308 315 Y 50.5 2198 93.9 95.0 95.2 0.81 235 6.9 2.2 1LL1212-3AC13-3■■■ 1LL1212-3AC33-3■■■ 305 409 315 Y 50.6 2915 94.0 95.1 95.4 0.83 305 6.5 2.0 350 469 315 Y 50.6 3345 94.1 95.2 95.6 0.84 345 6.3 2.0 1LL1212-3AC53-3■■■ 395 530 315 Δ 50.6 3774 94.3 95.4 95.7 0.85 385 6.4 2.0 1LL1212-3AC73-3■■■ 1LL1212-3BC53-3■■■ 480 644 355 Δ 50.5 4588 94.2 95.2 95.4 0.86 465 7.2 2.2 550 738 355 Δ 50.4 5255 94.4 95.5 95.6 0.86 530 7.6 1.9 1LL1212-3BC73-3■■■ 750 rpm, 6-pole 185 248 315 Y 38 2356 92.7 94.0 94.5 0.81 192 6.5 2.2 1LL1212-3AC13-4■■■ 240 322 315 Y 38.1 3058 93.1 94.4 94.9 0.83 240 6.4 2.1 1LL1212-3AC33-4■■■ 265 355 315 Δ 38.1 3377 93.1 94.4 95.0 0.84 265 6.1 2.0 1LL1212-3AC53-4■■■ 300 402 315 Δ 38.1 3823 93.2 94.5 95.1 0.85 295 6.0 1.9 1LL1212-3AC73-4■■■ 360 483 355 Y 37.9 4587 93.4 94.6 94.9 0.86 350 7.2 2.2 1LL1212-3BC53-4■■■ 410 550 355 Δ 37.9 5223 93.6 94.7 95.1 0.87 395 7.3 1.9 1LL1212-3BC73-4■■■ • Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V 3000 rpm, 4-pole 310 416 315 Δ 100.8 987 95.0 95.7 95.6 0.89 320 5.4 1.8 1LL1222-3AB13-1■■■ 1LL1222-3AB33-1■■■ 395 530 315 Δ 100.7 1258 95.3 96.0 95.9 0.90 400 5.8 1.9 460 617 315 Δ 100.7 1464 95.6 96.3 96.2 0.90 465 6.5 2.2 1LL1222-3AB53-1■■■ 520 697 315 Δ 100.7 1656 95.7 96.4 96.3 0.91 520 6.5 2.1 1LL1222-3AB73-1■■■ 1LL1222-3BB53-1■■■ 660 885 355 Δ 100.7 2103 94.6 95.2 94.9 0.89 680 4.7 1.7 670 898 355 Δ 100.8 2133 94.5 95.2 94.9 0.88 700 4.3 1.6 1LL1222-3BB73-1■■■ 1500 rpm, 4-pole 280 375 315 Δ 50.6 1783 94.0 95.1 95.2 0.88 295 6.4 2.3 1LL1222-3AB13-2■■■ 380 510 315 Δ 50.6 2420 94.1 95.2 95.5 0.89 390 6.4 2.3 1LL1222-3AB33-2■■■ 430 577 315 Δ 50.6 2739 94.3 95.4 95.7 0.90 440 6.7 2.4 1LL1222-3AB53-2■■■ 510 684 315 Δ 50.6 3248 94.6 95.6 95.9 0.90 520 7.0 2.3 1LL1222-3AB73-2■■■ 670 898 355 Δ 50.6 4267 94.7 95.8 96.0 0.88 700 6.0 2.3 1LL1222-3BB53-2■■■ 685 919 355 Δ 50.6 4362 94.6 95.7 96.0 0.89 700 5.6 2.1 1LL1222-3BB73-2■■■ 1000 rpm, 6-pole 220 295 315 Y 50.5 2103 94.0 95.0 95.2 0.81 250 7.0 2.2 1LL1222-3AC13-3■■■ 305 409 315 Δ 50.6 2915 94.0 95.1 95.4 0.83 340 6.5 2.1 1LL1222-3AC33-3■■■ 355 476 315 Δ 50.6 3392 94.2 95.3 95.6 0.84 390 6.2 2.0 1LL1222-3AC53-3■■■ 395 530 315 Δ 50.6 3774 94.3 95.4 95.7 0.84 430 6.7 2.0 1LL1222-3AC73-3■■■ 475 637 355 Δ 50.5 4540 94.2 95.3 95.4 0.87 500 7.2 2.2 1LL1222-3BC53-3■■■ 540 724 355 Δ 50.4 5159 94.5 95.5 95.6 0.86 580 7.7 1.9 1LL1222-3BC73-3■■■ 750 rpm, 6-pole 180 241 315 Y 38.1 2294 92.7 94.0 94.5 0.81 205 6.4 2.1 1LL1222-3AC13-4■■■ 245 329 315 Δ 38 3123 93.2 94.5 94.9 0.82 275 6.6 2.2 1LL1222-3AC33-4■■■ 270 362 315 Δ 38.1 3440 93.2 94.5 95.0 0.84 300 6.2 2.1 1LL1222-3AC53-4■■■ 290 389 315 Δ 38.1 3696 93.1 94.5 95.0 0.85 315 6.1 2.0 1LL1222-3AC73-4■■■ 365 489 355 Δ 37.9 4650 93.4 94.6 95.0 0.86 390 7.3 2.1 1LL1222-3BC53-4■■■ 395 530 355 Δ 38 5031 93.4 94.6 95.0 0.87 420 7.1 2.0 1LL1222-3BC73-4■■■ For versions, see Article No. supplements and special versions 1LL1222-3AC73-4■■■ 8/6 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Self-ventilated motors — open version 1LL1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LL1212-3AB13-1... 1LL1212-3AB33-1... 1LL1212-3AB53-1... 1LL1212-3AB73-1... 1LL1212-3BB53-1... 1LL1212-3BB73-1... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 320 400 452 560 710 710 1LL1212-3AB13-2... 1LL1212-3AB33-2... 1LL1212-3AB53-2... 1LL1212-3AB73-2... 1LL1212-3BB53-2... 1LL1212-3BB73-2... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 320 400 452 560 710 710 1LL1212-3AC13-3... 1LL1212-3AC33-3... 1LL1212-3AC53-3... 1LL1212-3AC73-3... 1LL1212-3BC53-3... 1LL1212-3BC73-3... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 250 320 400 400 560 560 1LL1212-3AC13-4... 1LL1212-3AC33-4... 1LL1212-3AC53-4... 1LL1212-3AC73-4... 1LL1212-3BC53-4... 1LL1212-3BC73-4... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 6SL3710-7LG32-2AA3 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 208 250 320 320 400 400 1LL1222-3AB13-1... 1LL1222-3AB33-1... 1LL1222-3AB53-1... 1LL1222-3AB73-1... 1LL1222-3BB53-1... 1LL1222-3BB73-1... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH35-8AA3 6SL3710-1GH35-8AA3 6SL3710-1GH37-4AA3 6SL3710-1GH37-4AA3 320 400 560 560 710 710 1LL1222-3AB13-2... 1LL1222-3AB33-2... 1LL1222-3AB53-2... 1LL1222-3AB73-2... 1LL1222-3BB53-2... 1LL1222-3BB73-2... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH37-4AA3 6SL3710-1GH37-4AA3 320 400 452 560 710 710 1LL1222-3AC13-3... 1LL1222-3AC33-3... 1LL1222-3AC53-3... 1LL1222-3AC73-3... 1LL1222-3BC53-3... 1LL1222-3BC73-3... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GH32-6AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH37-4AA3 250 400 400 452 560 710 1LL1222-3AC13-4... 1LL1222-3AC33-4... 1LL1222-3AC53-4... 1LL1222-3AC73-4... 1LL1222-3BC53-4... 1LL1222-3BC73-4... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-1GH32-2AA3 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 208 320 320 320 400 452 Siemens D 81.8 · 04/2014 8 8/7 © Siemens AG 2014 Self-ventilated motors — open version 1LL1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency ■ Selection and ordering data Prated 8 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated TB/ Trated 1LL1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V 3600 rpm, 4-pole 335 449 315 Δ 120.7 889 95.4 95.9 95.5 0.88 475 6.2 2.1 1LL1212-3AB15-5■■■ 415 557 315 Δ 120.6 1101 95.8 96.2 95.8 0.90 580 7.3 2.4 1LL1212-3AB35-5■■■ 1LL1212-3AB55-5■■■ 440 590 315 Δ 120.7 1168 95.8 96.3 96.0 0.90 610 6.2 2.0 505 677 315 Δ 120.7 1340 95.9 96.5 96.2 0.91 690 6.7 2.1 1LL1212-3AB75-5■■■ 3000 rpm, 4-pole 655 878 355 Δ 100.9 2085 94.4 95.2 94.9 0.88 940 4.1 1.5 1LL1212-3BB55-1■■■ 750 1006 355 Δ 100.8 2389 94.9 95.6 95.2 0.89 1060 4.7 1.7 1LL1212-3BB75-1■■■ 1800 rpm, 4-pole 340 456 315 Δ 60.6 1805 94.8 95.7 95.8 0.87 490 6.6 2.4 1LL1212-3AB15-6■■■ 1LL1212-3AB35-6■■■ 420 563 315 Δ 60.6 2229 95.0 95.9 96.1 0.89 590 6.7 2.4 465 624 315 Δ 60.6 2467 95.2 96.1 96.2 0.90 650 6.8 2.4 1LL1212-3AB55-6■■■ 1LL1212-3AB75-6■■■ 590 791 315 Δ 60.5 3130 95.7 96.5 96.5 0.89 830 8.1 2.4 795 1066 355 Δ 60.6 4219 95.2 96.1 96.3 0.89 1120 5.8 2.2 1LL1212-3BB55-6■■■ 1LL1212-3BB75-6■■■ 810 1086 355 Δ 60.7 4298 95.0 96.1 96.3 0.89 1140 5.3 2.0 1200 rpm, 6-pole 305 409 315 Δ 60.7 2428 94.2 95.3 95.6 0.82 470 5.8 1.8 1LL1212-3AC15-7■■■ 1LL1212-3AC35-7■■■ 375 503 315 Δ 60.7 2986 94.5 95.6 95.8 0.84 560 5.9 1.8 455 610 315 Δ 60.6 3622 94.9 95.8 96.0 0.84 680 6.3 1.9 1LL1212-3AC55-7■■■ 1LL1212-3AC75-7■■■ 485 650 315 Δ 60.6 3861 94.8 95.8 96.1 0.85 720 6.1 1.9 625 838 355 Δ 60.5 4975 94.9 95.8 95.8 0.86 910 7.1 2.0 1LL1212-3BC55-7■■■ 665 892 355 Δ 60.5 5294 95.0 95.9 95.9 0.87 960 7.2 1.9 1LL1212-3BC75-7■■■ 900 rpm, 6-pole 250 335 315 Δ 45.6 2654 93.6 94.8 95.2 0.81 390 6.0 2.0 1LL1212-3AC15-8■■■ 1LL1212-3AC35-8■■■ 315 422 315 Δ 45.6 3345 94 95.2 95.4 0.81 490 6.5 2.1 345 463 315 Δ 45.6 3662 93.8 95.1 95.5 0.84 520 5.8 1.9 1LL1212-3AC55-8■■■ 380 510 315 Δ 45.6 4033 94 95.2 95.6 0.85 560 6.1 1.8 1LL1212-3AC75-8■■■ 1LL1212-3BC55-8■■■ 455 610 355 Δ 45.5 4829 93.9 95.1 95.4 0.87 660 6.4 2.0 515 691 355 Δ 45.5 5464 94.1 95.2 95.5 0.87 750 6.6 1.8 1LL1212-3BC75-8■■■ • Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G120P, SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V 3600 rpm, 4-pole 340 456 315 Δ 120.6 902 95.5 95.9 95.5 0.88 530 6.5 2.2 1LL1222-3AB15-5■■■ 1LL1222-3AB35-5■■■ 400 536 315 Δ 120.7 1062 95.7 96.2 95.9 0.90 610 6.3 2.0 450 603 315 Δ 120.6 1194 95.9 96.4 96.0 0.90 680 7.0 2.3 1LL1222-3AB55-5■■■ 510 684 315 Δ 120.5 1353 96.1 96.5 96.1 0.91 760 8.1 2.6 1LL1222-3AB75-5■■■ 3000 rpm, 4-pole 680 912 355 Δ 100.8 2167 94.7 95.4 95.0 0.88 1060 4.6 1.7 1LL1222-3BB55-1■■■ 690 925 355 Δ 100.9 2197 94.6 95.3 95.1 0.88 1080 4.2 1.5 1LL1222-3BB75-1■■■ 1800 rpm, 4-pole 340 456 315 Δ 60.6 1805 94.8 95.7 95.8 0.87 540 6.5 2.4 1LL1222-3AB15-6■■■ 420 563 315 Δ 60.6 2229 95.1 96.0 96.1 0.89 650 6.9 2.4 1LL1222-3AB35-6■■■ 475 637 315 Δ 60.6 2521 95.3 96.2 96.3 0.90 720 7.2 2.5 1LL1222-3AB55-6■■■ 550 738 315 Δ 60.6 2918 95.4 96.3 96.4 0.90 830 7.3 2.5 1LL1222-3AB75-6■■■ 735 986 355 Δ 60.7 3900 94.9 96.0 96.2 0.89 1120 5.2 1.9 1LL1222-3BB55-6■■■ 850 1140 355 Δ 60.6 4511 95.3 96.2 96.4 0.89 1300 5.8 2.2 1LL1222-3BB75-6■■■ 1200 rpm, 6-pole 325 436 315 Δ 60.6 2587 94.5 95.5 95.7 0.82 540 6.3 1.9 1LL1222-3AC15-7■■■ 385 516 315 Δ 60.6 3065 94.6 95.6 95.9 0.83 640 6.1 1.9 1LL1222-3AC35-7■■■ 440 590 315 Δ 60.6 3503 94.8 95.8 96.0 0.84 720 6.2 1.9 1LL1222-3AC55-7■■■ 495 664 315 Δ 60.7 3941 94.8 95.9 96.1 0.85 800 5.9 1.8 1LL1222-3AC75-7■■■ 605 811 355 Δ 60.5 4815 94.9 95.8 95.8 0.86 960 7.2 2.1 1LL1222-3BC55-7■■■ 675 905 355 Δ 60.5 5373 95.0 95.9 95.9 0.87 1060 7.1 1.8 1LL1222-3BC75-7■■■ 900 rpm, 6-pole 245 329 315 Δ 45.6 2601 93.7 94.8 95.1 0.80 425 6.4 2.1 1LL1222-3AC15-8■■■ 1LL1222-3AC35-8■■■ 305 409 315 Δ 45.6 3239 93.9 95.0 95.4 0.82 510 6.3 2.0 345 463 315 Δ 45.6 3664 93.9 95.1 95.5 0.84 570 6.0 1.9 1LL1222-3AC55-8■■■ 375 503 315 Δ 45.6 3981 93.9 95.2 95.6 0.85 610 5.7 1.8 1LL1222-3AC75-8■■■ 465 624 355 Δ 45.5 4935 94.0 95.1 95.4 0.87 740 6.7 2.0 1LL1222-3BC55-8■■■ 520 697 355 Δ 45.5 5518 94.4 95.4 95.6 0.87 820 7.3 1.8 1LL1222-3BC75-8■■■ For versions, see Article No. supplements and special versions 1LL1222-3AC75-8■■■ 8/8 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Self-ventilated motors — open version 1LL1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency Motor type mIM B3 mIM V1 J LpfA, LWA, Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 tolerance +3 dB(A) no-load Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LL1212-3AB15-5... 1LL1212-3AB35-5... 1LL1212-3AB55-5... 1LL1212-3AB75-5... 1230 1410 1590 1750 1280 1460 1640 1800 3.4 4.3 4.9 5.7 79 79 79 79 94 94 94 94 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 477 590 725 725 1LL1212-3BB55-1... 1LL1212-3BB75-1... 2190 2310 2240 2370 8.1 8.8 79 79 95 95 3300 3300 1XB7 740 6SL3710-7LE41-0AA3 2 x 1XB7 740 6SL3710-7LE41-2AA3 960 1230 1LL1212-3AB15-6... 1LL1212-3AB35-6... 1LL1212-3AB55-6... 1LL1212-3AB75-6... 1LL1212-3BB55-6... 1LL1212-3BB75-6... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 3000 3000 3000 3000 2200 2200 1XB7 731 1XB7 731 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 6SL3710-7LE41-2AA3 590 590 725 960 1230 1230 1LL1212-3AC15-7... 1LL1212-3AC35-7... 1LL1212-3AC55-7... 1LL1212-3AC75-7... 1LL1212-3BC55-7... 1LL1212-3BC75-7... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-0AA3 477 590 725 725 960 960 1LL1212-3AC15-8... 1LL1212-3AC35-8... 1LL1212-3AC55-8... 1LL1212-3AC75-8... 1LL1212-3BC55-8... 1LL1212-3BC75-8... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 477 590 590 590 725 820 1LL1222-3AB15-5... 1LL1222-3AB35-5... 1LL1222-3AB55-5... 1LL1222-3AB75-5... 1230 1410 1590 1750 1280 1460 1640 1800 3.4 4.3 4.9 5.7 79 79 79 79 94 94 94 94 3600 3600 3600 3600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1PE35-8AA0 6SL3370-1PE36-6AA0 6SL3710-1PE37-4AA0 6SL3710-1GE38-4AA3 570 640 710 820 1LL1222-3BB55-1... 1LL1222-3BB75-1... 2190 2310 2240 2370 8.1 8.8 79 79 95 95 3300 3300 2 x 1XB7 740 6SL3710-2GE41-1AA3 2 x 1XB7 740 6SL3710-2GE41-1AA3 1092 1092 1LL1222-3AB15-6... 1LL1222-3AB35-6... 1LL1222-3AB55-6... 1LL1222-3AB75-6... 1LL1222-3BB55-6... 1LL1222-3BB75-6... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 3000 3000 3000 3000 2200 2200 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-1PE35-8AA0 6SL3710-1PE37-4AA0 6SL3710-1GE37-5AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-4AA3 6SL3710-2GE41-4AA3 570 710 725 960 1340 1340 1LL1222-3AC15-7... 1LL1222-3AC35-7... 1LL1222-3AC55-7... 1LL1222-3AC75-7... 1LL1222-3BC55-7... 1LL1222-3BC75-7... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-1PE35-8AA0 6SL3370-1PE36-6AA0 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 570 640 725 820 960 1092 1LL1222-3AC15-8... 1LL1222-3AC35-8... 1LL1222-3AC55-8... 1LL1222-3AC75-8... 1LL1222-3BC55-8... 1LL1222-3BC75-8... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1PE34-6AA0 6SL3710-1PE35-8AA0 6SL3710-1PE35-8AA0 6SL3370-1PE36-6AA0 6SL3710-1GE38-4AA3 6SL3710-1GE38-4AA3 450 570 570 640 820 820 Siemens D 81.8 · 04/2014 8 8/9 © Siemens AG 2014 Self-ventilated motors — open version 1LL1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency ■ Selection and ordering data Prated 8 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated TB/ Trated 1LL1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V 3600 rpm, 4-pole 315 422 315 Δ 120.7 836 95.2 95.7 95.3 0.88 355 5.9 2.0 1LL1212-3AB16-5■■■ 400 536 315 Δ 120.6 1061 95.7 96.1 95.7 0.90 440 7.3 2.4 1LL1212-3AB36-5■■■ 1LL1212-3AB56-5■■■ 445 597 315 Δ 120.6 1181 95.8 96.3 95.9 0.90 485 7.7 2.5 505 677 315 Δ 120.5 1340 96.0 96.4 96.1 0.91 540 8.0 2.6 1LL1212-3AB76-5■■■ 3000 rpm, 4-pole 630 845 355 Δ 100.9 2006 94.3 95.0 94.7 0.88 710 4.2 1.5 1LL1212-3BB56-1■■■ 705 945 355 Δ 100.8 2246 94.6 95.3 95.0 0.89 790 4.5 1.6 1LL1212-3BB76-1■■■ 1800 rpm, 4-pole 305 409 315 Δ 60.6 1619 94.6 95.5 95.6 0.88 345 6.6 2.4 1LL1212-3AB16-6■■■ 1LL1212-3AB36-6■■■ 400 536 315 Δ 60.5 2122 95.2 96.0 96.0 0.88 450 7.9 2.8 445 597 315 Δ 60.5 2361 95.2 96.1 96.2 0.89 490 7.7 2.7 1LL1212-3AB56-6■■■ 1LL1212-3AB76-6■■■ 545 731 315 Δ 60.5 2891 95.6 96.4 96.4 0.89 600 8.6 2.6 745 999 355 Δ 60.6 3954 95.1 96.0 96.2 0.89 830 6.0 2.2 1LL1212-3BB56-6■■■ 1LL1212-3BB76-6■■■ 825 1106 355 Δ 60.5 4378 95.3 96.2 96.3 0.89 910 6.5 2.3 1200 rpm, 6-pole 295 396 315 Δ 60.6 2348 94.3 95.3 95.5 0.82 355 6.5 2.0 1LL1212-3AC16-7■■■ 1LL1212-3AC36-7■■■ 360 483 315 Δ 60.6 2868 94.6 95.5 95.7 0.83 430 6.6 2.0 405 543 315 Δ 60.6 3224 94.6 95.6 95.8 0.84 475 6.3 1.9 1LL1212-3AC56-7■■■ 1LL1212-3AC76-7■■■ 450 603 315 Δ 60.6 3584 94.7 95.7 95.9 0.85 520 6.5 1.9 590 791 355 Δ 60.4 4698 94.9 95.7 95.7 0.86 680 8.0 2.1 1LL1212-3BC56-7■■■ 640 858 355 Δ 60.4 5096 94.9 95.8 95.8 0.87 730 7.7 1.9 1LL1212-3BC76-7■■■ 900 rpm, 6-pole 225 302 315 Y 45.6 2389 93.3 94.5 94.9 0.81 280 6.3 2.1 1LL1212-3AC16-8■■■ 1LL1212-3AC36-8■■■ 295 396 315 Δ 45.5 3132 94.0 95.1 95.3 0.82 360 6.8 2.2 325 436 315 Δ 45.6 3451 93.9 95.1 95.4 0.84 385 6.4 2.0 1LL1212-3AC56-8■■■ 360 483 315 Δ 45.5 3823 94.1 95.2 95.5 0.84 425 6.8 1.9 1LL1212-3AC76-8■■■ 1LL1212-3BC56-8■■■ 435 583 355 Δ 45.5 4616 94.0 95.1 95.3 0.86 500 7.3 2.1 485 650 355 Δ 45.5 5147 94.1 95.2 95.4 0.87 550 7.3 1.9 1LL1212-3BC76-8■■■ • Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V 3600 rpm, 4-pole 315 422 315 Δ 120.6 836 95.4 95.8 95.3 0.89 390 7.2 2.4 1LL1222-3AB16-5■■■ 1LL1222-3AB36-5■■■ 385 516 315 Δ 120.5 1021 95.7 96.1 95.6 0.89 475 7.8 2.6 425 570 315 Δ 120.5 1127 95.9 96.2 95.8 0.90 520 8.4 2.8 1LL1222-3AB56-5■■■ 470 630 315 Δ 120.6 1247 95.8 96.4 96.1 0.91 560 6.9 2.2 1LL1222-3AB76-5■■■ 3000 rpm, 4-pole 625 838 355 Δ 100.8 1990 94.4 95.1 94.7 0.88 780 4.3 1.6 1LL1222-3BB56-1■■■ 700 939 355 Δ 100.7 2230 94.7 95.4 95.0 0.89 870 4.8 1.7 1LL1222-3BB76-1■■■ 1800 rpm, 4-pole 300 402 315 Δ 60.6 1592 94.5 95.4 95.6 0.88 375 6.3 2.3 1LL1222-3AB16-6■■■ 395 530 315 Δ 60.5 2096 95.1 95.9 96.0 0.88 490 7.7 2.7 1LL1222-3AB36-6■■■ 440 590 315 Δ 60.5 2335 95.2 96.1 96.2 0.89 540 7.6 2.7 1LL1222-3AB56-6■■■ 540 724 315 Δ 60.5 2865 95.6 96.4 96.4 0.89 660 9.0 2.6 1LL1222-3AB76-6■■■ 740 992 355 Δ 60.6 3927 95.1 96.1 96.2 0.89 910 6.2 2.3 1LL1222-3BB56-6■■■ 760 1019 355 Δ 60.6 4033 95.0 96.0 96.2 0.89 930 5.7 2.1 1LL1222-3BB76-6■■■ 1200 rpm, 6-pole 275 369 315 Δ 60.7 2189 94.0 95.1 95.4 0.83 365 6.0 1.8 1LL1222-3AC16-7■■■ 355 476 315 Δ 60.6 2828 94.5 95.5 95.7 0.83 470 6.6 2.0 1LL1222-3AC36-7■■■ 405 543 315 Δ 60.6 3225 94.6 95.6 95.8 0.84 530 6.3 1.9 1LL1222-3AC56-7■■■ 450 603 315 Δ 60.6 3584 94.8 95.8 96.0 0.85 580 6.7 2.0 1LL1222-3AC76-7■■■ 560 751 355 Δ 60.5 4459 94.8 95.7 95.7 0.86 710 7.8 2.2 1LL1222-3BC56-7■■■ 635 852 355 Δ 60.4 5055 95.0 95.9 95.8 0.86 810 8.4 2.0 1LL1222-3BC76-7■■■ 900 rpm, 6-pole 230 308 315 Δ 45.6 2442 93.5 94.6 94.9 0.80 320 6.7 2.2 1LL1222-3AC16-8■■■ 1LL1222-3AC36-8■■■ 285 382 315 Δ 45.5 3025 93.9 95.0 95.2 0.81 390 7.1 2.3 325 436 315 Δ 45.5 3451 93.9 95.1 95.4 0.83 430 6.7 2.1 1LL1222-3AC56-8■■■ 355 476 315 Δ 45.5 3769 94.1 95.2 95.5 0.84 465 6.8 2.0 1LL1222-3AC76-8■■■ 430 577 355 Δ 45.5 4563 94.0 95.1 95.3 0.86 550 7.2 2.2 1LL1222-3BC56-8■■■ 475 637 355 Δ 45.4 5043 94.1 95.2 95.4 0.87 600 7.5 2.0 1LL1222-3BC76-8■■■ For versions, see Article No. supplements and special versions 1LL1222-3AC76-8■■■ 8/10 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Self-ventilated motors — open version 1LL1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LL1212-3AB16-5... 1LL1212-3AB36-5... 1LL1212-3AB56-5... 1LL1212-3AB76-5... 1230 1410 1590 1750 1280 1460 1640 1800 3.4 4.3 4.9 5.7 79 79 79 79 94 94 94 94 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 400 452 560 560 1LL1212-3BB56-1... 1LL1212-3BB76-1... 2190 2310 2240 2370 8.1 8.8 79 79 95 95 3300 3300 1XB7 740 1XB7 740 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 710 790 1LL1212-3AB16-6... 1LL1212-3AB36-6... 1LL1212-3AB56-6... 1LL1212-3AB76-6... 1LL1212-3BB56-6... 1LL1212-3BB76-6... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 3000 3000 3000 3000 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-8AA3 6SL3710-7LG41-0AA3 400 452 560 710 880 1000 1LL1212-3AC16-7... 1LL1212-3AC36-7... 1LL1212-3AC56-7... 1LL1212-3AC76-7... 1LL1212-3BC56-7... 1LL1212-3BC76-7... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 400 452 560 560 710 790 1LL1212-3AC16-8... 1LL1212-3AC36-8... 1LL1212-3AC56-8... 1LL1212-3AC76-8... 1LL1212-3BC56-8... 1LL1212-3BC76-8... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 320 400 400 452 560 560 1LL1222-3AB16-5... 1LL1222-3AB36-5... 1LL1222-3AB56-5... 1LL1222-3AB76-5... 1230 1410 1590 1750 1280 1460 1640 1800 3.4 4.3 4.9 5.7 79 79 79 79 94 94 94 94 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GF34-1AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 400 560 560 560 1LL1222-3BB56-1... 1LL1222-3BB76-1... 2190 2310 2240 2370 8.1 8.8 79 79 95 95 3300 3300 1XB7 740 1XB7 740 6SL3710-1GF38-1AA3 6SL3710-2GF41-1AA3 790 1036 1LL1222-3AB16-6... 1LL1222-3AB36-6... 1LL1222-3AB56-6... 1LL1222-3AB76-6... 1LL1222-3BB56-6... 1LL1222-3BB76-6... 1230 1410 1590 1750 2190 2310 1280 1460 1640 1800 2240 2370 3.4 4.3 4.9 5.7 8.1 8.8 79 79 79 79 79 79 94 94 94 94 95 95 3000 3000 3000 3000 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GF34-1AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-2GF41-1AA3 6SL3710-2GF41-1AA3 400 560 560 710 1036 1036 1LL1222-3AC16-7... 1LL1222-3AC36-7... 1LL1222-3AC56-7... 1LL1222-3AC76-7... 1LL1222-3BC56-7... 1LL1222-3BC76-7... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GF34-1AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 6SL3710-2GF38-6AA3 400 560 560 710 710 836 1LL1222-3AC16-8... 1LL1222-3AC36-8... 1LL1222-3AC56-8... 1LL1222-3AC76-8... 1LL1222-3BC56-8... 1LL1222-3BC76-8... 1260 1440 1620 1730 2180 2330 1310 1490 1670 1780 2240 2380 5.8 7.1 8.2 9.0 14.3 15.8 79 79 79 79 79 79 94 94 94 94 95 95 2500 2500 2500 2500 2200 2200 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GF33-3AA3 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 320 400 452 560 560 710 Siemens D 81.8 · 04/2014 8 8/11 © Siemens AG 2014 Self-ventilated motors — open version Dimensions 1LL1 motors ■ Dimensional drawings IM B5 type of construction For terminal box dimensions, see Page 8/14. L LL BE HB' HK HC GA HD AC ØD F HB AG AD BC H HA EB DB BA E G_D081_XX_00416 C ØK B BB Ø K' AA A AB IM B35 and IM V1 types of construction For flange dimensions, see Page 8/13 (Z = the number of retaining holes), For terminal box dimensions, see Page 8/14 L 8 LL HC HB' HK HH BE AG AD LM HB ZxS GA AQ AC ØP ØN ØD F E DB G_D081_XX_00417 BA LA LE C Frame No. of size poles Motor type 315 1LL12..-3A.1.-.... 1LL12..-3A.3.-.... 4, 6 4, 6 1LL12..-3A.5.-…. 1LL12..-3A.7.-…. ØK Ø K' B BB AA AB AC AQ B BA BB C H HA K K' L LM D 560 120 680 630 670 630 180 780 180 315 28 28 35 1470 1615 85 ● 560 120 680 630 670 630 180 780 200 315 28 28 35 1490 1635 95 560 120 680 630 670 835 180 985 180 315 28 28 35 1610 1775 85 DB E EB F GA M20 170 140 22 90 M24 170 140 25 100 M20 170 140 22 90 ● 560 120 680 630 670 835 180 985 200 315 28 28 35 1630 1775 95 M24 170 140 25 100 630 150 780 710 750 800 220 980 200 355 35 35 42 1730 1900 95 M24 170 140 25 100 ● 630 150 780 710 750 800 220 980 224 355 35 35 42 1795 1965 100 M24 210 180 28 106 ● Bearing design for increased cantilever forces, for type of construction IM B3 only. 8/12 AA A AB Dimension designation acc. to IEC A 1LL12..-3A.5.-.... 1LL12..-3A.7.-.... 355 M H HA EB HD T Siemens D 81.8 · 04/2014 © Siemens AG 2014 Self-ventilated motors — open version Dimensions Flanges G_D081_XX_00026 ■ Dimensional drawings (Z = the number of retaining holes) Flange with through holes Motor type Frame size No. of poles Type of construction Flange type Dimension designation acc. to IEC LA 1LL1 315 355 4, 6 4, 6 IM B35, IM V1 IM B35, IM V1 LE M N P S T Z 8 Flange 29 170 740 680 800 22 6 Flange (optional) 22 170 600 550 660 22 6 8 Flange 29 170 840 780 900 22 6 8 Flange (optional) 22 170 600 550 660 22 6 8 8 Siemens D 81.8 · 04/2014 8/13 © Siemens AG 2014 Self-ventilated motors — open version Dimensions Terminal boxes ■ Dimensional drawings LL BE HB' HK HC AG1 IM B3 type of construction HD HB AG AD BC G_D081_XX_00426 LL HC HB' HK HH AG1 IM B35 and IM V1 types of construction HB 8 HD AG AD BE G_D081_XX_00427 Motor type Frame size No. of poles Terminal box Dimension designation acc. to IEC AD AG AG1 BC BE HB HB' HH HC HD HK LL 1LL1 315 4, 6 1XB7 730 710 575 – 115 – 890 310 295 180 1025 255 345 1XB7 731 710 575 – 115 115 890 310 295 180 1025 255 345 1XB7 740 800 615 60 115 150 930 365 295 235 1110 340 425 GT640 655 555 – 115 110 870 225 295 155 970 170 310 1XB1 621 705 585 – 115 150 900 305 295 165 1020 250 330 1XB1 631 775 640 – 115 100 955 400 295 175 1090 320 555 1XB7 730 750 615 – 100 – 970 310 300 180 1105 255 345 1XB7 731 750 615 – 100 115 970 310 300 180 1105 255 345 1XB7 740 840 655 60 100 150 1010 365 300 235 1190 340 425 GT640 695 595 – 100 110 950 225 300 155 1050 170 310 1XB1 621 745 625 – 100 150 980 305 300 165 1100 250 330 1XB1 631 815 680 – 100 100 1035 400 300 175 1170 320 555 355 8/14 4, 6 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors – open version 9/2 9 9/2 9/2 9/4 9/6 9/6 9/8 9/10 9/10 9/12 9/14 9/14 9/16 9/18 9/18 9/20 1LP1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency – low noise High Efficiency – increased output Line voltage 500 V, 50 Hz High Efficiency – low noise High Efficiency – increased output Line voltage 690 V, 50 Hz High Efficiency – low noise High Efficiency – increased output Line voltage 460 V, 60 Hz High Efficiency – low noise High Efficiency – increased output Line voltage 575 V, 60 Hz High Efficiency – low noise High Efficiency – increased output 9/22 9/22 9/22 9/23 9/24 9/25 Dimensions 1LP1 motors • Radially mounted equipment unit • Axially mounted equipment unit Flanges Terminal boxes Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency – low noise ■ Selection and ordering data Prated 9 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated T B/ Trated 1LP1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V 3000 rpm, 4-pole 335 449 315 Δ 100.9 1067 94.8 95.7 95.7 0.88 540 4.6 1.6 1LP1212-3AB11-1■■■ 420 563 315 Δ 100.9 1338 95.2 96.1 96.1 0.89 670 5.0 1.7 1LP1212-3AB31-1■■■ 1LP1212-3AB51-1■■■ 470 630 315 Δ 100.8 1497 95.5 96.3 96.2 0.90 740 5.4 1.8 545 731 315 Δ 100.8 1736 95.7 96.4 96.4 0.91 840 5.8 1.9 1LP1212-3AB71-1■■■ 685 919 355 Δ 100.8 2181 95.4 96.4 96.4 0.88 1100 4.2 1.5 1LP1212-3BB51-1■■■ 1LP1212-3BB71-1■■■ 690 925 355 Δ 100.9 2197 95.3 96.3 96.4 0.88 1100 4.0 1.4 1500 rpm, 4-pole 305 409 315 Δ 50.7 1943 94.1 95.3 95.7 0.88 495 5.7 2.1 1LP1212-3AB11-2■■■ 1LP1212-3AB31-2■■■ 405 543 315 Δ 50.6 2579 94.6 95.7 96.1 0.89 650 6.4 2.3 445 597 315 Δ 50.6 2834 94.7 95.8 96.2 0.90 700 6.6 2.3 1LP1212-3AB51-2■■■ 510 684 315 Δ 50.6 3248 94.8 95.9 96.3 0.90 800 6.5 2.3 1LP1212-3AB71-2■■■ 640 858 355 Δ 50.7 4076 94.6 95.8 96.3 0.89 1020 5.0 1.9 1LP1212-3BB51-2■■■ 725 972 355 Δ 50.6 4616 94.9 96.0 96.4 0.89 1160 5.4 2.1 1LP1212-3BB71-2■■■ 1000 rpm, 6-pole 280 375 315 Δ 50.7 2675 93.8 95.0 95.5 0.82 490 5.8 1.8 1LP1212-3AC11-3■■■ 1LP1212-3AC31-3■■■ 345 463 315 Δ 50.7 3295 94.1 95.3 95.7 0.83 590 5.9 1.8 390 523 315 Δ 50.7 3725 94.2 95.4 95.8 0.84 660 5.8 1.8 1LP1212-3AC51-3■■■ 435 583 315 Δ 50.6 4157 94.5 95.6 95.9 0.84 740 6.2 1.8 1LP1212-3AC71-3■■■ 1LP1212-3BC51-3■■■ 545 731 355 Δ 50.5 5206 94.3 95.4 95.8 0.86 900 6.4 1.9 630 845 355 Δ 50.5 6019 94.6 95.6 95.9 0.86 1040 7.0 1.6 1LP1212-3BC71-3■■■ 750 rpm, 6-pole 230 308 315 Δ 38.2 2930 92.3 93.8 94.6 0.81 410 5.4 1.8 1LP1212-3AC11-4■■■ 285 382 315 Δ 38.2 3629 92.7 94.2 94.9 0.83 495 5.4 1.8 1LP1212-3AC31-4■■■ 315 422 315 Δ 38.2 4012 92.8 94.3 95.0 0.85 530 5.3 1.7 1LP1212-3AC51-4■■■ 350 469 315 Δ 38.2 4458 93.0 94.5 95.2 0.85 590 5.3 1.7 1LP1212-3AC71-4■■■ 425 570 355 Δ 38.1 5414 92.7 94.3 94.9 0.87 700 5.6 1.8 1LP1212-3BC51-4■■■ 485 650 355 Δ 38.1 6178 92.9 94.4 95.1 0.88 790 5.7 1.6 1LP1212-3BC71-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V 3000 rpm, 4-pole 325 436 315 Δ 100.9 1035 94.9 95.7 95.7 0.88 590 4.7 1.6 1LP1222-3AB11-1■■■ 1LP1222-3AB31-1■■■ 420 563 315 Δ 100.8 1338 95.4 96.1 96.1 0.89 750 5.2 1.8 475 637 315 Δ 100.7 1513 95.6 96.4 96.3 0.90 830 5.9 1.9 1LP1222-3AB51-1■■■ 490 657 315 Δ 100.9 1561 95.4 96.2 96.3 0.90 860 5.0 1.7 1LP1222-3AB71-1■■■ 1LP1222-3BB51-1■■■ 710 952 355 Δ 100.7 2262 95.7 96.5 96.5 0.89 1260 4.8 1.7 720 966 355 Δ 100.8 2292 95.6 96.5 96.5 0.88 1280 4.4 1.6 1LP1222-3BB71-1■■■ 1500 rpm, 4-pole 320 429 315 Δ 50.6 2038 94.3 95.4 95.8 0.87 590 6.0 2.2 1LP1222-3AB11-2■■■ 400 536 315 Δ 50.6 2548 94.6 95.7 96.0 0.89 710 6.4 2.3 1LP1222-3AB31-2■■■ 450 603 315 Δ 50.6 2866 94.8 95.8 96.2 0.90 790 6.6 2.3 1LP1222-3AB51-2■■■ 520 697 315 Δ 50.6 3311 94.9 95.9 96.3 0.90 920 6.6 2.2 1LP1222-3AB71-2■■■ 650 872 355 Δ 50.7 4139 94.7 95.9 96.3 0.89 1160 5.1 2.0 1LP1222-3BB51-2■■■ 755 1012 355 Δ 50.6 4808 95.0 96.2 96.5 0.89 1340 5.7 2.1 1LP1222-3BB71-2■■■ 1000 rpm, 6-pole 280 375 315 Δ 50.7 2675 93.7 95.0 95.5 0.82 550 5.5 1.8 1LP1222-3AC11-3■■■ 350 469 315 Δ 50.7 3343 94.1 95.3 95.7 0.83 670 5.9 1.8 1LP1222-3AC31-3■■■ 390 523 315 Δ 50.6 3725 94.3 95.5 95.8 0.84 740 6.1 1.9 1LP1222-3AC51-3■■■ 440 590 315 Δ 50.7 4203 94.4 95.5 95.9 0.85 820 5.8 1.8 1LP1222-3AC71-3■■■ 555 744 355 Δ 50.5 5301 94.5 95.5 95.8 0.86 1020 6.9 1.9 1LP1222-3BC51-3■■■ 625 838 355 Δ 50.5 5970 94.5 95.6 95.9 0.87 1140 6.7 1.7 1LP1222-3BC71-3■■■ 750 rpm, 6-pole 235 315 315 Δ 38.2 2993 92.5 94.0 94.7 0.81 470 5.3 1.8 1LP1222-3AC11-4■■■ 290 389 315 Δ 38.2 3696 92.8 94.3 94.9 0.82 570 5.6 1.9 1LP1222-3AC31-4■■■ 320 429 315 Δ 38.1 4076 93.0 94.4 95.1 0.84 610 5.6 1.8 1LP1222-3AC51-4■■■ 350 469 315 Δ 38.2 4458 92.9 94.4 95.1 0.85 660 5.3 1.7 1LP1222-3AC71-4■■■ 425 570 355 Δ 38.1 5414 92.8 94.3 95.0 0.87 790 5.5 1.8 1LP1222-3BC51-4■■■ 485 650 355 Δ 38.1 6178 93.0 94.5 95.1 0.88 890 5.8 1.6 1LP1222-3BC71-4■■■ For versions, see Article No. supplements and special versions 1LP1222-3AC71-4■■■ 9/2 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency – low noise Motor type mIM B3 mIM V1 J LpfA, LWA, Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 tolerance +3 dB(A) no-load Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LP1212-3AB11-1... 1LP1212-3AB31-1... 1LP1212-3AB51-1... 1LP1212-3AB71-1... 1LP1212-3BB51-1... 1LP1212-3BB71-1... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 6SL3710-7LE41-2AA3 590 725 820 960 1230 1230 1LP1212-3AB11-2... 1LP1212-3AB31-2... 1LP1212-3AB51-2... 1LP1212-3AB71-2... 1LP1212-3BB51-2... 1LP1212-3BB71-2... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-2AA3 6SL3710-7LE41-2AA3 590 725 725 820 1230 1230 1LP1212-3AC11-3... 1LP1212-3AC31-3... 1LP1212-3AC51-3... 1LP1212-3AC71-3... 1LP1212-3BC51-3... 1LP1212-3BC71-3... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 590 590 725 820 960 1230 1LP1212-3AC11-4... 1LP1212-3AC31-4... 1LP1212-3AC51-4... 1LP1212-3AC71-4... 1LP1212-3BC51-4... 1LP1212-3BC71-4... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 477 590 590 590 725 820 1LP1222-3AB11-1... 1LP1222-3AB31-1... 1LP1222-3AB51-1... 1LP1222-3AB71-1... 1LP1222-3BB51-1... 1LP1222-3BB71-1... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-4AA3 6SL3710-2GE41-4AA3 590 820 960 960 1340 1340 1LP1222-3AB11-2... 1LP1222-3AB31-2... 1LP1222-3AB51-2... 1LP1222-3AB71-2... 1LP1222-3BB51-2... 1LP1222-3BB71-2... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-4AA3 6SL3710-2GE41-4AA3 590 725 820 960 1340 1340 1LP1222-3AC11-3... 1LP1222-3AC31-3... 1LP1222-3AC51-3... 1LP1222-3AC71-3... 1LP1222-3BC51-3... 1LP1222-3BC71-3... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE38-4AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-4AA3 590 725 820 820 1092 1340 1LP1222-3AC11-4... 1LP1222-3AC31-4... 1LP1222-3AC51-4... 1LP1222-3AC71-4... 1LP1222-3BC51-4... 1LP1222-3BC71-4... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 477 590 725 725 820 960 Siemens D 81.8 · 04/2014 9 9/3 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency – increased output ■ Selection and ordering data Prated 9 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated T B/ Trated 1LP1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V 3000 rpm, 4-pole 370 496 315 Δ 101.0 1178 94.5 95.5 95.7 0.87 600 4.2 1.4 1LP1312-3AB11-1■■■ 465 624 316 Δ 101.0 1480 94.9 95.9 96.0 0.89 740 4.5 1.5 1LP1312-3AB31-1■■■ 530 711 317 Δ 100.9 1689 95.2 96.1 96.2 0.90 830 4.8 1.6 1LP1312-3AB51-1■■■ 615 825 318 Δ 100.9 1959 95.4 96.3 96.4 0.90 960 5.0 1.7 1LP1312-3AB71-1■■■ 725 972 355 Δ 101.0 2309 95.1 96.3 96.4 0.87 1180 3.7 1.4 1LP1312-3BB71-1■■■ 1500 rpm, 4-pole 320 429 315 Δ 50.7 2037 93.8 95.1 95.6 0.88 520 5.5 2.0 1LP1312-3AB11-2■■■ 450 603 316 Δ 50.7 2866 94.1 95.3 95.8 0.89 720 5.7 2.0 1LP1312-3AB31-2■■■ 500 671 317 Δ 50.7 3184 94.2 95.4 95.9 0.90 790 5.8 2.1 1LP1312-3AB51-2■■■ 575 771 318 Δ 50.7 3661 94.3 95.5 96.0 0.91 900 5.8 2.0 1LP1312-3AB71-2■■■ 670 898 355 Δ 50.7 4267 94.4 95.7 96.2 0.89 1060 4.8 1.8 1LP1312-3BB51-2■■■ 760 1019 355 Δ 50.7 4839 94.7 95.9 96.4 0.89 1200 5.2 2.0 1LP1312-3BB71-2■■■ 1000 rpm, 6-pole 270 362 315 Δ 50.6 2579 93.8 95.0 95.4 0.82 470 6.0 1.9 1LP1312-3AC11-3■■■ 370 496 316 Δ 50.7 3535 93.6 95.0 95.5 0.83 640 5.4 1.7 1LP1312-3AC31-3■■■ 425 570 317 Δ 50.7 4061 93.7 95.1 95.6 0.84 720 5.3 1.7 1LP1312-3AC51-3■■■ 480 644 318 Δ 50.7 4586 94.0 95.3 95.7 0.84 810 5.7 1.6 1LP1312-3AC71-3■■■ 565 758 355 Δ 50.6 5397 94.1 95.4 95.7 0.87 920 6.2 1.8 1LP1312-3BC51-3■■■ 650 872 355 Δ 50.5 6208 94.5 95.6 95.8 0.86 1080 6.7 1.6 1LP1312-3BC71-3■■■ 750 rpm, 6-pole 250 335 315 Δ 38.3 3183 91.6 93.3 94.3 0.81 450 4.9 1.7 1LP1312-3AC11-4■■■ 310 416 316 Δ 38.2 3948 92.0 93.8 94.6 0.83 540 5.0 1.6 1LP1312-3AC31-4■■■ 345 463 317 Δ 38.3 4396 92.0 93.8 94.7 0.85 590 4.8 1.6 1LP1312-3AC51-4■■■ 385 516 318 Δ 38.3 4905 92.2 94.0 94.8 0.85 650 4.8 1.5 1LP1312-3AC71-4■■■ 435 583 355 Δ 38.1 5541 92.6 94.2 94.9 0.87 720 5.4 1.8 1LP1312-3BC51-4■■■ 500 671 355 Δ 38.1 6368 92.8 94.3 95.0 0.88 820 5.5 1.6 1LP1312-3BC71-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V 3000 rpm, 4-pole 360 483 315 Δ 101.0 1146 94.5 95.5 95.6 0.88 650 4.2 1.4 1LP1322-3AB11-1■■■ 470 630 316 Δ 100.9 1496 95.0 96.0 96.1 0.89 840 4.7 1.6 1LP1322-3AB31-1■■■ 540 724 317 Δ 100.9 1720 95.4 96.2 96.3 0.90 950 5.1 1.7 1LP1322-3AB51-1■■■ 1LP1322-3AB71-1■■■ 550 738 318 Δ 101.0 1751 95.0 96.0 96.2 0.89 980 4.4 1.5 750 1006 355 Δ 100.8 2389 95.6 96.5 96.5 0.88 1340 4.5 1.6 1LP1322-3BB51-1■■■ 760 1019 355 Δ 100.9 2420 95.4 96.4 96.5 0.88 1360 4.2 1.5 1LP1322-3BB71-1■■■ 1500 rpm, 4-pole 355 476 315 Δ 50.7 2260 93.8 95.1 95.6 0.87 650 5.5 2.0 1LP1322-3AB11-2■■■ 445 597 316 Δ 50.7 2833 94.1 95.3 95.8 0.89 800 5.7 2.0 1LP1322-3AB31-2■■■ 505 677 317 Δ 50.7 3216 94.2 95.5 96.0 0.90 890 5.9 2.1 1LP1322-3AB51-2■■■ 585 784 318 Δ 50.7 3725 94.4 95.6 96.1 0.90 1040 5.9 2.0 1LP1322-3AB71-2■■■ 685 919 355 Δ 50.7 4363 94.5 95.8 96.3 0.89 1220 4.9 1.9 1LP1322-3BB51-2■■■ 795 1066 355 Δ 50.6 5062 94.9 96.1 96.4 0.89 1420 5.4 2.0 1LP1322-3BB71-2■■■ 1000 rpm, 6-pole 265 355 315 Δ 50.7 2531 93.7 95.0 95.4 0.82 520 5.9 1.9 1LP1322-3AC11-3■■■ 375 503 316 Δ 50.7 3582 93.7 95.0 95.5 0.83 720 5.5 1.7 1LP1322-3AC31-3■■■ 430 577 317 Δ 50.7 4107 93.8 95.1 95.6 0.84 820 5.5 1.7 1LP1322-3AC51-3■■■ 480 644 318 Δ 50.7 4586 93.9 95.2 95.7 0.85 900 5.3 1.6 1LP1322-3AC71-3■■■ 575 771 355 Δ 50.5 5492 94.3 95.5 95.8 0.86 1060 6.6 1.8 1LP1322-3BC51-3■■■ 645 865 355 Δ 50.5 6161 94.4 95.5 95.8 0.87 1180 6.5 1.6 1LP1322-3BC71-3■■■ 750 rpm, 6-pole 255 342 315 Δ 38.3 3247 91.8 93.5 94.4 0.82 510 4.9 1.7 1LP1322-3AC11-4■■■ 1LP1322-3AC31-4■■■ 315 422 316 Δ 38.2 4011 92.2 93.8 94.6 0.82 620 5.1 1.7 350 469 317 Δ 38.2 4459 92.3 93.9 94.8 0.84 670 5.1 1.7 1LP1322-3AC51-4■■■ 380 510 318 Δ 38.3 4842 92.2 94.0 94.8 0.85 720 4.9 1.5 1LP1322-3AC71-4■■■ 440 590 355 Δ 38.1 5606 92.6 94.2 94.9 0.87 820 5.3 1.8 1LP1322-3BC51-4■■■ 500 671 355 Δ 38.1 6368 92.9 94.4 95.0 0.88 910 5.7 1.6 1LP1322-3BC71-4■■■ For versions, see Article No. supplements and special versions 1LP1222-3AC71-4■■■ 9/4 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 400 V, 50 Hz High Efficiency – increased output Motor type mIM B3 mIM V1 J LpfA, LWA, Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 tolerance +3 dB(A) no-load Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LP1312-3AB11-1... 1LP1312-3AB31-1... 1LP1312-3AB51-1... 1LP1312-3AB71-1... 1LP1312-3BB71-1... 1280 1470 1640 1800 2380 1330 1520 1690 1850 2440 3.3 4.2 4.8 5.7 8.7 85 85 85 85 85 100.5 100.5 100.5 100.5 101 3600 3600 3600 3600 3300 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 725 820 960 960 1230 1LP1312-3AB11-2... 1LP1312-3AB31-2... 1LP1312-3AB51-2... 1LP1312-3AB71-2... 1LP1312-3BB51-2... 1LP1312-3BB71-2... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 6SL3710-7LE41-2AA3 590 725 820 960 1230 1230 1LP1312-3AC11-3... 1LP1312-3AC31-3... 1LP1312-3AC51-3... 1LP1312-3AC71-3... 1LP1312-3BC51-3... 1LP1312-3BC71-3... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 477 725 725 820 960 1230 1LP1312-3AC11-4... 1LP1312-3AC31-4... 1LP1312-3AC51-4... 1LP1312-3AC71-4... 1LP1312-3BC51-4... 1LP1312-3BC71-4... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 477 590 590 725 725 820 1LP1322-3AB11-1... 1LP1322-3AB31-1... 1LP1322-3AB51-1... 1LP1322-3AB71-1... 1LP1322-3BB51-1... 1LP1322-3BB71-1... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3600 3600 3600 3600 3300 3300 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-1GE37-5AA3 6SL3710-1GE41-0AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-4AA3 6SL3710-2GE41-6AA3 725 960 960 1092 1340 1516 1LP1322-3AB11-2... 1LP1322-3AB31-2... 1LP1322-3AB51-2... 1LP1322-3AB71-2... 1LP1322-3BB51-2... 1LP1322-3BB71-2... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-4AA3 6SL3710-2GE41-6AA3 725 820 960 1092 1340 1516 1LP1322-3AC11-3... 1LP1322-3AC31-3... 1LP1322-3AC51-3... 1LP1322-3AC71-3... 1LP1322-3BC51-3... 1LP1322-3BC71-3... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-4AA3 590 725 820 960 1092 1340 1LP1322-3AC11-4... 1LP1322-3AC31-4... 1LP1322-3AC51-4... 1LP1322-3AC71-4... 1LP1322-3BC51-4... 1LP1322-3BC71-4... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 590 725 725 725 820 960 Siemens D 81.8 · 04/2014 9 9/5 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency – low noise ■ Selection and ordering data Prated 9 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated T B/ Trated 1LP1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V 3000 rpm, 4-pole 315 422 315 Δ 100.8 1003 94.9 95.7 95.6 0.88 415 5.1 1.7 1LP1212-3AB12-1■■■ 415 557 315 Δ 100.7 1321 95.4 96.1 96.0 0.90 530 6.1 2.0 1LP1212-3AB32-1■■■ 1LP1212-3AB52-1■■■ 460 617 315 Δ 100.7 1465 95.6 96.3 96.2 0.90 590 6.3 2.1 480 644 315 Δ 100.8 1529 95.4 96.2 96.2 0.90 620 5.3 1.8 1LP1212-3AB72-1■■■ 680 912 355 Δ 100.7 2166 95.5 96.4 96.4 0.89 880 4.8 1.7 1LP1212-3BB52-1■■■ 1LP1212-3BB72-1■■■ 700 939 355 Δ 100.8 2229 95.3 96.3 96.4 0.88 920 4.3 1.6 1500 rpm, 4-pole 285 382 315 Δ 50.7 1815 94.0 95.2 95.6 0.88 380 6.0 2.2 1LP1212-3AB12-2■■■ 1LP1212-3AB32-2■■■ 360 483 315 Δ 50.6 2293 94.4 95.5 95.9 0.89 470 6.4 2.3 420 563 315 Δ 50.6 2675 94.7 95.8 96.1 0.90 540 7.1 2.5 1LP1212-3AB52-2■■■ 505 677 315 Δ 50.5 3216 95.1 96.0 96.3 0.89 660 7.7 2.3 1LP1212-3AB72-2■■■ 675 905 355 Δ 50.6 4299 94.7 95.9 96.3 0.89 880 5.6 2.1 1LP1212-3BB52-2■■■ 755 1012 355 Δ 50.6 4808 94.9 96.0 96.4 0.89 980 6.1 2.1 1LP1212-3BB72-2■■■ 1000 rpm, 6-pole 270 362 315 Δ 50.6 2579 93.8 95.0 95.4 0.82 385 6.0 1.9 1LP1212-3AC12-3■■■ 1LP1212-3AC32-3■■■ 320 429 315 Δ 50.6 3058 94.0 95.2 95.6 0.83 450 6.3 2.0 355 476 315 Δ 50.6 3391 94.0 95.2 95.7 0.84 495 6.0 1.9 1LP1212-3AC52-3■■■ 395 530 315 Δ 50.6 3774 94.2 95.4 95.8 0.85 540 6.2 1.9 1LP1212-3AC72-3■■■ 1LP1212-3BC52-3■■■ 510 684 355 Δ 50.5 4874 94.2 95.3 95.6 0.86 690 6.9 2.0 580 778 355 Δ 50.5 5542 94.4 95.5 95.7 0.87 780 7.2 1.8 1LP1212-3BC72-3■■■ 750 rpm, 6-pole 215 288 315 Δ 38.1 2740 92.3 93.8 94.5 0.81 315 5.8 1.9 1LP1212-3AC12-4■■■ 265 355 315 Δ 38.1 3375 92.6 94.1 94.7 0.83 375 5.9 1.9 1LP1212-3AC32-4■■■ 285 382 315 Δ 38.1 3630 92.6 94.1 94.9 0.84 400 5.5 1.8 1LP1212-3AC52-4■■■ 320 429 315 Δ 38.1 4076 93.0 94.4 95.0 0.84 450 5.8 1.8 1LP1212-3AC72-4■■■ 415 557 355 Δ 38 5285 93.0 94.4 94.9 0.87 560 6.4 1.9 1LP1212-3BC52-4■■■ 440 590 355 Δ 38 5605 92.9 94.3 94.9 0.88 590 6.1 1.8 1LP1212-3BC72-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V 3000 rpm, 4-pole 330 443 315 Δ 100.8 1051 95.0 95.8 95.7 0.88 470 5.0 1.7 1LP1222-3AB12-1■■■ 1LP1222-3AB32-1■■■ 420 563 315 Δ 100.8 1338 95.2 96.1 96.1 0.89 590 5.1 1.7 470 630 315 Δ 100.8 1497 95.4 96.2 96.2 0.90 650 5.3 1.7 1LP1222-3AB52-1■■■ 535 717 315 Δ 100.8 1704 95.6 96.4 96.4 0.90 740 5.4 1.8 1LP1222-3AB72-1■■■ 1LP1222-3BB52-1■■■ 670 898 355 Δ 100.9 2133 95.3 96.3 96.4 0.88 950 4.1 1.5 765 1026 355 Δ 100.8 2437 95.7 96.5 96.5 0.89 1080 4.6 1.7 1LP1222-3BB72-1■■■ 1500 rpm, 4-pole 305 409 315 Δ 50.7 1942 94.0 95.2 95.7 0.88 440 5.5 2.0 1LP1222-3AB12-2■■■ 415 557 315 Δ 50.6 2643 94.7 95.7 96.1 0.88 590 6.6 2.4 1LP1222-3AB32-2■■■ 455 610 315 Δ 50.6 2898 94.8 95.8 96.2 0.90 630 6.7 2.4 1LP1222-3AB52-2■■■ 510 684 315 Δ 50.6 3248 94.8 95.9 96.3 0.90 710 6.6 2.3 1LP1222-3AB72-2■■■ 715 959 355 Δ 50.6 4553 95.0 96.1 96.4 0.88 1020 5.7 2.2 1LP1222-3BB52-2■■■ 725 972 355 Δ 50.6 4617 94.8 96.0 96.4 0.89 1020 5.3 2.0 1LP1222-3BB72-2■■■ 1000 rpm, 6-pole 265 355 315 Δ 50.7 2531 93.7 95.0 95.5 0.82 410 5.5 1.8 1LP1222-3AC12-3■■■ 355 476 315 Δ 50.6 3391 94.1 95.3 95.7 0.83 540 5.9 1.9 1LP1222-3AC32-3■■■ 390 523 315 Δ 50.6 3726 94.2 95.4 95.8 0.84 590 5.8 1.8 1LP1222-3AC52-3■■■ 435 583 315 Δ 50.6 4155 94.4 95.6 95.9 0.84 650 6.1 1.8 1LP1222-3AC72-3■■■ 540 724 355 Δ 50.6 5158 94.2 95.4 95.7 0.87 780 6.3 1.9 1LP1222-3BC52-3■■■ 620 831 355 Δ 50.5 5922 94.5 95.6 95.9 0.87 900 6.6 1.7 1LP1222-3BC72-3■■■ 750 rpm, 6-pole 230 308 315 Δ 38.2 2931 92.2 93.8 94.6 0.81 365 5.2 1.8 1LP1222-3AC12-4■■■ 285 382 315 Δ 38.2 3629 92.7 94.2 94.9 0.83 440 5.4 1.8 1LP1222-3AC32-4■■■ 310 416 315 Δ 38.2 3949 92.6 94.2 95.0 0.84 470 5.1 1.7 1LP1222-3AC52-4■■■ 340 456 315 Δ 38.2 4331 92.7 94.3 95.0 0.85 510 5.1 1.7 1LP1222-3AC72-4■■■ 435 583 355 Δ 38.1 5540 92.9 94.4 95.0 0.87 640 5.7 1.8 1LP1222-3BC52-4■■■ 485 650 355 Δ 38.1 6177 93.0 94.5 95.1 0.88 700 5.8 1.6 1LP1222-3BC72-4■■■ For versions, see Article No. supplements and special versions 1LP1222-3AC72-4■■■ 9/6 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency – low noise Motor type mIM B3 mIM V1 J LpfA, LWA, Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 tolerance +3 dB(A) no-load Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LP1212-3AB12-1... 1LP1212-3AB32-1... 1LP1212-3AB52-1... 1LP1212-3AB72-1... 1LP1212-3BB52-1... 1LP1212-3BB72-1... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-8AA3 6SL3710-7LG41-0AA3 452 560 710 710 880 1000 1LP1212-3AB12-2... 1LP1212-3AB32-2... 1LP1212-3AB52-2... 1LP1212-3AB72-2... 1LP1212-3BB52-2... 1LP1212-3BB72-2... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-8AA3 6SL3710-7LG41-0AA3 400 560 560 710 880 1000 1LP1212-3AC12-3... 1LP1212-3AC32-3... 1LP1212-3AC52-3... 1LP1212-3AC72-3... 1LP1212-3BC52-3... 1LP1212-3BC72-3... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 400 452 560 560 710 790 1LP1212-3AC12-4... 1LP1212-3AC32-4... 1LP1212-3AC52-4... 1LP1212-3AC72-4... 1LP1212-3BC52-4... 1LP1212-3BC72-4... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 320 400 400 452 560 710 1LP1222-3AB12-1... 1LP1222-3AB32-1... 1LP1222-3AB52-1... 1LP1222-3AB72-1... 1LP1222-3BB52-1... 1LP1222-3BB72-1... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 477 590 725 820 960 1092 1LP1222-3AB12-2... 1LP1222-3AB32-2... 1LP1222-3AB52-2... 1LP1222-3AB72-2... 1LP1222-3BB52-2... 1LP1222-3BB72-2... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-1AA3 477 590 725 725 1092 1092 1LP1222-3AC12-3... 1LP1222-3AC32-3... 1LP1222-3AC52-3... 1LP1222-3AC72-3... 1LP1222-3BC52-3... 1LP1222-3BC72-3... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 477 590 590 725 820 960 1LP1222-3AC12-4... 1LP1222-3AC32-4... 1LP1222-3AC52-4... 1LP1222-3AC72-4... 1LP1222-3BC52-4... 1LP1222-3BC72-4... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GE33-8AA3 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 370 477 477 590 725 725 Siemens D 81.8 · 04/2014 9 9/7 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency – increased output ■ Selection and ordering data Prated 9 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated T B/ Trated 1LP1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V 3000 rpm, 4-pole 355 476 315 Δ 100.9 1130 94.5 95.5 95.6 0.88 470 4.5 1.5 1LP1312-3AB12-1■■■ 470 630 316 Δ 100.8 1497 95.2 96.0 96.0 0.90 600 5.4 1.8 1LP1312-3AB32-1■■■ 1LP1312-3AB52-1■■■ 525 704 317 Δ 100.8 1672 95.3 96.1 96.2 0.90 670 5.6 1.8 540 724 318 Δ 100.9 1719 95.0 96.0 96.1 0.90 690 4.8 1.6 1LP1312-3AB72-1■■■ 725 972 355 Δ 100.8 2310 95.4 96.3 96.4 0.88 950 4.4 1.6 1LP1312-3BB52-1■■■ 1LP1312-3BB72-1■■■ 735 986 355 Δ 100.9 2340 95.2 96.3 96.4 0.88 960 4.1 1.5 1500 rpm, 4-pole 285 382 315 Δ 50.7 1815 93.9 95.1 95.5 0.88 380 6.0 2.2 1LP1312-3AB12-2■■■ 1LP1312-3AB32-2■■■ 405 543 316 Δ 50.7 2579 93.8 95.1 95.7 0.90 530 5.6 2.0 475 637 317 Δ 50.7 3025 94.2 95.4 95.9 0.90 610 6.2 2.2 1LP1312-3AB52-2■■■ 575 771 318 Δ 50.6 3661 94.6 95.7 96.1 0.90 740 6.9 2.0 1LP1312-3AB72-2■■■ 710 952 355 Δ 50.6 4521 94.5 95.8 96.2 0.89 920 5.4 2.0 1LP1312-3BB52-2■■■ 800 1073 355 Δ 50.6 5095 94.7 95.9 96.3 0.89 1040 5.7 1.9 1LP1312-3BB72-2■■■ 1000 rpm, 6-pole 260 349 315 Δ 50.6 2483 93.8 95.0 95.4 0.82 370 6.2 2.0 1LP1312-3AC12-3■■■ 1LP1312-3AC32-3■■■ 335 449 316 Δ 50.6 3200 93.7 95.0 95.4 0.83 470 6.0 1.9 375 503 317 Δ 50.7 3583 93.7 95.0 95.5 0.84 520 5.7 1.8 1LP1312-3AC52-3■■■ 435 583 318 Δ 50.7 4156 93.6 95.0 95.5 0.85 600 5.6 1.7 1LP1312-3AC72-3■■■ 1LP1312-3BC52-3■■■ 525 704 355 Δ 50.5 5015 94.1 95.3 95.6 0.86 710 6.7 2.0 605 811 355 Δ 50.5 5781 94.3 95.4 95.7 0.87 810 6.9 1.7 1LP1312-3BC72-3■■■ 750 rpm, 6-pole 235 315 315 Δ 38.2 2995 91.6 93.2 94.2 0.81 345 5.3 1.8 1LP1312-3AC12-4■■■ 280 375 316 Δ 38.2 3566 92.1 93.7 94.5 0.83 400 5.5 1.8 1LP1312-3AC32-4■■■ 310 416 317 Δ 38.2 3950 91.9 93.6 94.5 0.85 435 5.1 1.7 1LP1312-3AC52-4■■■ 355 476 318 Δ 38.2 4521 92.2 93.8 94.7 0.85 495 5.2 1.6 1LP1312-3AC72-4■■■ 425 570 355 Δ 38.0 5413 92.9 94.3 94.9 0.87 580 6.2 1.8 1LP1312-3BC52-4■■■ 455 610 355 Δ 38.1 5796 92.7 94.2 94.9 0.88 610 5.9 1.7 1LP1312-3BC72-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V 3000 rpm, 4-pole 380 510 315 Δ 101.0 1210 94.6 95.6 95.7 0.88 540 4.3 1.5 1LP1322-3AB12-1■■■ 1LP1322-3AB32-1■■■ 470 630 316 Δ 101.0 1496 94.9 95.9 96.0 0.89 660 4.5 1.5 525 704 317 Δ 100.9 1671 95.1 96.1 96.2 0.89 740 4.6 1.6 1LP1322-3AB52-1■■■ 605 811 318 Δ 100.9 1926 95.3 96.2 96.3 0.90 840 4.8 1.6 1LP1322-3AB72-1■■■ 1LP1322-3BB52-1■■■ 705 945 355 Δ 100.9 2245 95.2 96.2 96.4 0.87 1020 3.8 1.4 810 1086 355 Δ 100.8 2579 95.6 96.5 96.6 0.88 1140 4.4 1.6 1LP1322-3BB72-1■■■ 1500 rpm, 4-pole 305 409 315 Δ 50.7 1942 93.8 95.1 95.6 0.88 440 5.5 2.0 1LP1322-3AB12-2■■■ 460 617 316 Δ 50.7 2930 94.2 95.4 95.9 0.89 650 5.9 2.1 1LP1322-3AB32-2■■■ 515 691 317 Δ 50.7 3279 94.2 95.5 96.0 0.90 720 5.9 2.1 1LP1322-3AB52-2■■■ 575 771 318 Δ 50.7 3662 94.3 95.5 96.0 0.90 800 5.8 2.0 1LP1322-3AB72-2■■■ 750 1006 355 Δ 50.6 4776 94.8 96.0 96.4 0.89 1060 5.5 2.1 1LP1322-3BB52-2■■■ 760 1019 355 Δ 50.7 4839 94.6 95.9 96.4 0.89 1080 5.0 1.9 1LP1322-3BB72-2■■■ 1000 rpm, 6-pole 250 335 315 Δ 50.6 2388 93.7 95.0 95.4 0.82 385 5.9 1.9 1LP1322-3AC12-3■■■ 385 516 316 Δ 50.7 3678 93.6 95.0 95.5 0.83 590 5.4 1.7 1LP1322-3AC32-3■■■ 430 577 317 Δ 50.7 4109 93.6 95.0 95.6 0.84 650 5.2 1.6 1LP1322-3AC52-3■■■ 480 644 318 Δ 50.7 4586 93.9 95.2 95.7 0.84 720 5.5 1.6 1LP1322-3AC72-3■■■ 560 751 355 Δ 50.6 5350 94.1 95.3 95.7 0.87 810 6.1 1.9 1LP1322-3BC52-3■■■ 640 858 355 Δ 50.5 6114 94.4 95.5 95.8 0.87 930 6.4 1.6 1LP1322-3BC72-3■■■ 750 rpm, 6-pole 250 335 315 Δ 38.3 3184 91.5 93.3 94.2 0.82 395 4.8 1.6 1LP1322-3AC12-4■■■ 305 409 316 Δ 38.2 3885 92.1 93.8 94.6 0.83 470 5.0 1.7 1LP1322-3AC32-4■■■ 335 449 317 Δ 38.3 4269 91.9 93.7 94.6 0.85 510 4.7 1.6 1LP1322-3AC52-4■■■ 370 496 318 Δ 38.3 4716 91.9 93.8 94.7 0.85 560 4.7 1.5 1LP1322-3AC72-4■■■ 450 603 355 Δ 38.1 5732 92.7 94.3 94.9 0.87 660 5.5 1.7 1LP1322-3BC52-4■■■ 500 671 355 Δ 38.1 6369 92.8 94.4 95.0 0.88 720 5.7 1.6 1LP1322-3BC72-4■■■ For versions, see Article No. supplements and special versions 1LP1222-3AC72-4■■■ 9/8 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 500 V, 50 Hz High Efficiency – increased output Motor type mIM B3 mIM V1 J LpfA, LWA, Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 tolerance +3 dB(A) no-load Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LP1312-3AB12-1... 1LP1312-3AB32-1... 1LP1312-3AB52-1... 1LP1312-3AB72-1... 1LP1312-3BB52-1... 1LP1312-3BB72-1... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 6SL3710-7LG41-0AA3 6SL3710-7LG41-0AA3 560 710 710 710 1000 1000 1LP1312-3AB12-2... 1LP1312-3AB32-2... 1LP1312-3AB52-2... 1LP1312-3AB72-2... 1LP1312-3BB52-2... 1LP1312-3BB72-2... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 6SL3710-7LG41-0AA3 6SL3710-7LG41-3AA3 400 560 710 790 1000 1230 1LP1312-3AC12-3... 1LP1312-3AC32-3... 1LP1312-3AC52-3... 1LP1312-3AC72-3... 1LP1312-3BC52-3... 1LP1312-3BC72-3... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-8AA3 400 560 560 710 710 880 1LP1312-3AC12-4... 1LP1312-3AC32-4... 1LP1312-3AC52-4... 1LP1312-3AC72-4... 1LP1312-3BC52-4... 1LP1312-3BC72-4... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 400 400 452 560 710 710 1LP1322-3AB12-1... 1LP1322-3AB32-1... 1LP1322-3AB52-1... 1LP1322-3AB72-1... 1LP1322-3BB52-1... 1LP1322-3BB72-1... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-4AA3 590 725 820 960 1092 1340 1LP1322-3AB12-2... 1LP1322-3AB32-2... 1LP1322-3AB52-2... 1LP1322-3AB72-2... 1LP1322-3BB52-2... 1LP1322-3BB72-2... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-1AA3 477 725 725 820 1092 1092 1LP1322-3AC12-3... 1LP1322-3AC32-3... 1LP1322-3AC52-3... 1LP1322-3AC72-3... 1LP1322-3BC52-3... 1LP1322-3BC72-3... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 477 590 725 725 820 960 1LP1322-3AC12-4... 1LP1322-3AC32-4... 1LP1322-3AC52-4... 1LP1322-3AC72-4... 1LP1322-3BC52-4... 1LP1322-3BC72-4... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 477 477 590 590 725 725 Siemens D 81.8 · 04/2014 9 9/9 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency – low noise ■ Selection and ordering data Prated 9 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated T B/ Trated 1LP1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V 3000 rpm, 4-pole 315 422 315 Δ 100.8 1003 94.8 95.6 95.6 0.88 295 5.0 1.7 1LP1212-3AB13-1■■■ 415 557 315 Δ 100.7 1322 95.3 96.1 96.0 0.90 380 5.7 1.9 1LP1212-3AB33-1■■■ 1LP1212-3AB53-1■■■ 475 637 315 Δ 100.7 1512 95.6 96.3 96.2 0.90 435 6.4 2.1 530 711 315 Δ 100.7 1688 95.7 96.4 96.3 0.91 480 6.3 2.0 1LP1212-3AB73-1■■■ 695 932 355 Δ 100.8 2214 95.4 96.3 96.4 0.88 650 4.4 1.6 1LP1212-3BB53-1■■■ 1LP1212-3BB73-1■■■ 705 945 355 Δ 100.9 2245 95.2 96.3 96.4 0.88 660 4.1 1.5 1500 rpm, 4-pole 290 389 315 Δ 50.6 1847 94.1 95.2 95.6 0.88 275 6.2 2.2 1LP1212-3AB13-2■■■ 1LP1212-3AB33-2■■■ 375 503 315 Δ 50.6 2388 94.6 95.6 95.9 0.88 355 6.9 2.5 430 577 315 Δ 50.6 2738 94.8 95.9 96.1 0.89 400 7.2 2.6 1LP1212-3AB53-2■■■ 490 657 315 Δ 50.5 3120 94.9 96.0 96.2 0.90 450 7.6 2.4 1LP1212-3AB73-2■■■ 660 885 355 Δ 50.6 4203 94.6 95.9 96.3 0.89 610 5.4 2.1 1LP1212-3BB53-2■■■ 715 959 355 Δ 50.6 4553 94.7 95.9 96.3 0.89 660 5.6 2.1 1LP1212-3BB73-2■■■ 1000 rpm, 6-pole 245 329 315 Y 50.6 2341 93.9 95.0 95.4 0.82 250 6.4 2.0 1LP1212-3AC13-3■■■ 1LP1212-3AC33-3■■■ 320 429 315 Y 50.6 3056 93.9 95.1 95.6 0.83 320 6.2 1.9 360 483 315 Y 50.6 3439 94.1 95.3 95.7 0.84 355 6.1 1.9 1LP1212-3AC53-3■■■ 405 543 315 Δ 50.6 3870 94.3 95.4 95.8 0.85 395 6.2 1.9 1LP1212-3AC73-3■■■ 1LP1212-3BC53-3■■■ 505 677 355 Δ 50.5 4826 94.2 95.3 95.6 0.86 485 6.9 2.1 585 784 355 Δ 50.5 5590 94.4 95.5 95.7 0.87 560 7.2 1.8 1LP1212-3BC73-3■■■ 750 rpm, 6-pole 210 282 315 Y 38.1 2675 92.2 93.7 94.4 0.81 220 5.7 1.9 1LP1212-3AC13-4■■■ 270 362 315 Y 38.1 3438 92.6 94.1 94.8 0.83 275 5.6 1.9 1LP1212-3AC33-4■■■ 290 389 315 Δ 38.1 3693 92.7 94.2 94.9 0.84 290 5.6 1.8 1LP1212-3AC53-4■■■ 325 436 315 Δ 38.2 4138 92.9 94.3 95.0 0.85 320 5.6 1.8 1LP1212-3AC73-4■■■ 405 543 355 Y 38 5157 93.0 94.4 94.9 0.87 390 6.4 1.9 1LP1212-3BC53-4■■■ 465 624 355 Δ 38 5921 93.1 94.5 95.0 0.87 445 6.4 1.7 1LP1212-3BC73-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V 3000 rpm, 4-pole 320 429 315 Δ 100.8 1019 94.9 95.7 95.6 0.89 330 5.2 1.8 1LP1222-3AB13-1■■■ 1LP1222-3AB33-1■■■ 395 530 315 Δ 100.7 1258 95.3 96.1 96.0 0.90 400 5.8 1.9 460 617 315 Δ 100.7 1464 95.6 96.3 96.2 0.90 465 6.5 2.2 1LP1222-3AB53-1■■■ 525 704 315 Δ 100.7 1672 95.7 96.4 96.3 0.91 520 6.5 2.1 1LP1222-3AB73-1■■■ 1LP1222-3BB53-1■■■ 675 905 355 Δ 100.8 2151 95.5 96.4 96.4 0.89 690 4.7 1.7 690 925 355 Δ 100.8 2197 95.3 96.3 96.4 0.88 710 4.2 1.5 1LP1222-3BB73-1■■■ 1500 rpm, 4-pole 295 396 315 Δ 50.7 1879 94.1 95.3 95.7 0.88 310 6.1 2.2 1LP1222-3AB13-2■■■ 370 496 315 Δ 50.6 2356 94.4 95.6 95.9 0.89 380 6.5 2.3 1LP1222-3AB33-2■■■ 410 550 315 Δ 50.6 2611 94.7 95.8 96.1 0.90 415 7.1 2.5 1LP1222-3AB53-2■■■ 490 657 315 Δ 50.6 3120 94.9 95.9 96.2 0.90 495 7.4 2.4 1LP1222-3AB73-2■■■ 690 925 355 Δ 50.6 4394 94.9 96.0 96.3 0.88 710 6.0 2.3 1LP1222-3BB53-2■■■ 695 932 355 Δ 50.6 4426 94.7 95.9 96.3 0.89 710 5.6 2.1 1LP1222-3BB73-2■■■ 1000 rpm, 6-pole 245 329 315 Y 50.6 2342 93.8 95.0 95.4 0.82 275 6.4 2.0 1LP1222-3AC13-3■■■ 320 429 315 Δ 50.6 3057 94.0 95.2 95.6 0.83 355 6.2 2.0 1LP1222-3AC33-3■■■ 365 489 315 Δ 50.6 3486 94.2 95.3 95.7 0.84 400 6.1 1.9 1LP1222-3AC53-3■■■ 400 536 315 Δ 50.6 3823 94.4 95.5 95.8 0.84 435 6.6 1.9 1LP1222-3AC73-3■■■ 500 671 355 Δ 50.5 4775 94.2 95.3 95.6 0.86 530 6.7 2.1 1LP1222-3BC53-3■■■ 575 771 355 Δ 50.5 5493 94.4 95.5 95.7 0.87 610 7.3 1.8 1LP1222-3BC73-3■■■ 750 rpm, 6-pole 205 275 315 Y 38.2 2610 92.1 93.7 94.4 0.82 235 5.6 1.9 1LP1222-3AC13-4■■■ 275 369 315 Δ 38.1 3505 92.8 94.2 94.8 0.82 310 5.9 1.9 1LP1222-3AC33-4■■■ 290 389 315 Δ 38.1 3693 92.9 94.3 95.0 0.84 320 5.8 1.9 1LP1222-3AC53-4■■■ 315 422 315 Δ 38.1 4011 92.8 94.3 95.0 0.85 345 5.6 1.8 1LP1222-3AC73-4■■■ 410 550 355 Δ 38 5221 93.0 94.4 95.0 0.87 435 6.5 1.9 1LP1222-3BC53-4■■■ 445 597 355 Δ 38 5668 93.0 94.4 95.0 0.88 470 6.3 1.7 1LP1222-3BC73-4■■■ For versions, see Article No. supplements and special versions 1LP1222-3AC73-4■■■ 9/10 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency – low noise Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LP1212-3AB13-1... 1LP1212-3AB33-1... 1LP1212-3AB53-1... 1LP1212-3AB73-1... 1LP1212-3BB53-1... 1LP1212-3BB73-1... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 320 400 452 560 710 710 1LP1212-3AB13-2... 1LP1212-3AB33-2... 1LP1212-3AB53-2... 1LP1212-3AB73-2... 1LP1212-3BB53-2... 1LP1212-3BB73-2... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 320 400 400 452 710 710 1LP1212-3AC13-3... 1LP1212-3AC33-3... 1LP1212-3AC53-3... 1LP1212-3AC73-3... 1LP1212-3BC53-3... 1LP1212-3BC73-3... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 250 320 400 400 560 560 1LP1212-3AC13-4... 1LP1212-3AC33-4... 1LP1212-3AC53-4... 1LP1212-3AC73-4... 1LP1212-3BC53-4... 1LP1212-3BC73-4... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 250 320 320 320 400 452 1LP1222-3AB13-1... 1LP1222-3AB33-1... 1LP1222-3AB53-1... 1LP1222-3AB73-1... 1LP1222-3BB53-1... 1LP1222-3BB73-1... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH35-8AA3 6SL3710-1GH35-8AA3 6SL3710-1GH37-4AA3 6SL3710-1GH37-4AA3 400 400 560 560 710 710 1LP1222-3AB13-2... 1LP1222-3AB33-2... 1LP1222-3AB53-2... 1LP1222-3AB73-2... 1LP1222-3BB53-2... 1LP1222-3BB73-2... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH37-4AA3 6SL3710-1GH37-4AA3 320 400 452 560 710 710 1LP1222-3AC13-3... 1LP1222-3AC33-3... 1LP1222-3AC53-3... 1LP1222-3AC73-3... 1LP1222-3BC53-3... 1LP1222-3BC73-3... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH37-4AA3 320 400 400 452 560 710 1LP1222-3AC13-4... 1LP1222-3AC33-4... 1LP1222-3AC53-4... 1LP1222-3AC73-4... 1LP1222-3BC53-4... 1LP1222-3BC73-4... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-1GH32-6AA3 6SL3710-1GH33-3AA3 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 250 320 320 400 452 560 Siemens D 81.8 · 04/2014 9 9/11 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency – increased output ■ Selection and ordering data Prated 9 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated T B/ Trated 1LP1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V 3000 rpm, 4-pole 350 469 315 Δ 100.9 1114 94.4 95.4 95.5 0.88 330 4.5 1.5 1LP1312-3AB13-1■■■ 465 624 316 Δ 100.8 1481 95.0 95.9 96.0 0.89 430 5.1 1.7 1LP1312-3AB33-1■■■ 1LP1312-3AB53-1■■■ 545 731 317 Δ 100.8 1736 95.3 96.2 96.2 0.90 500 5.6 1.8 605 811 318 Δ 100.8 1927 95.4 96.2 96.3 0.91 550 5.5 1.8 1LP1312-3AB73-1■■■ 735 986 355 Δ 100.9 2340 95.3 96.3 96.4 0.88 690 4.2 1.5 1LP1312-3BB53-1■■■ 1LP1312-3BB73-1■■■ 740 992 355 Δ 100.9 2356 95.1 96.2 96.4 0.88 690 3.9 1.4 1500 rpm, 4-pole 295 396 315 Δ 50.6 1879 93.9 95.1 95.5 0.88 280 6.1 2.2 1LP1312-3AB13-2■■■ 1LP1312-3AB33-2■■■ 420 563 316 Δ 50.7 2675 94.1 95.3 95.7 0.89 390 6.3 2.2 485 650 317 Δ 50.6 3089 94.3 95.5 95.9 0.90 445 6.5 2.3 1LP1312-3AB53-2■■■ 555 744 318 Δ 50.6 3535 94.5 95.6 96.0 0.90 510 6.7 2.1 1LP1312-3AB73-2■■■ 695 932 355 Δ 50.7 4426 94.5 95.7 96.2 0.89 650 5.1 2.0 1LP1312-3BB53-2■■■ 755 1012 355 Δ 50.7 4808 94.5 95.8 96.3 0.89 700 5.2 2.0 1LP1312-3BB73-2■■■ 1000 rpm, 6-pole 235 315 315 Y 50.6 2246 93.8 95.0 95.3 0.82 240 6.7 2.1 1LP1312-3AC13-3■■■ 1LP1312-3AC33-3■■■ 320 429 316 Y 50.6 3056 93.8 95.0 95.5 0.83 320 6.2 1.9 390 523 317 Y 50.7 3726 93.6 95.0 95.5 0.84 385 5.6 1.8 1LP1312-3AC53-3■■■ 445 597 318 Δ 50.7 4252 93.8 95.1 95.6 0.85 435 5.7 1.7 1LP1312-3AC73-3■■■ 1LP1312-3BC53-3■■■ 525 704 355 Δ 50.5 5014 94.0 95.2 95.6 0.86 510 6.5 2.0 605 811 355 Δ 50.5 5781 94.3 95.4 95.7 0.87 580 6.9 1.7 1LP1312-3BC73-3■■■ 750 rpm, 6-pole 225 302 315 Y 38.2 2867 91.6 93.2 94.1 0.81 235 5.3 1.8 1LP1312-3AC13-4■■■ 290 389 316 Y 38.2 3693 92.0 93.7 94.5 0.84 290 5.3 1.7 1LP1312-3AC33-4■■■ 315 422 317 Δ 38.2 4013 92.0 93.7 94.6 0.84 315 5.2 1.7 1LP1312-3AC53-4■■■ 355 476 318 Δ 38.2 4523 92.1 93.9 94.7 0.85 350 5.1 1.6 1LP1312-3AC73-4■■■ 415 557 355 Y 38.0 5285 92.9 94.3 94.9 0.87 400 6.3 1.9 1LP1312-3BC53-4■■■ 470 630 355 Δ 38.0 5986 93.1 94.5 95.0 0.87 450 6.4 1.7 1LP1312-3BC73-4■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V 3000 rpm, 4-pole 360 483 315 Δ 100.9 1146 94.5 95.5 95.6 0.88 375 4.6 1.6 1LP1322-3AB13-1■■■ 1LP1322-3AB33-1■■■ 440 590 316 Δ 100.8 1402 95.0 95.9 96.0 0.89 450 5.1 1.7 530 711 317 Δ 100.8 1688 95.4 96.2 96.2 0.90 540 5.6 1.9 1LP1322-3AB53-1■■■ 600 805 318 Δ 100.8 1911 95.4 96.3 96.3 0.91 600 5.6 1.8 1LP1322-3AB73-1■■■ 1LP1322-3BB53-1■■■ 715 959 355 Δ 100.8 2276 95.3 96.3 96.4 0.88 740 4.4 1.6 725 972 355 Δ 100.9 2309 95.2 96.2 96.4 0.88 750 4.0 1.5 1LP1322-3BB73-1■■■ 1500 rpm, 4-pole 305 409 315 Δ 50.7 1943 93.8 95.1 95.6 0.88 320 5.9 2.1 1LP1322-3AB13-2■■■ 410 550 316 Δ 50.7 2611 93.9 95.2 95.7 0.89 425 5.8 2.1 1LP1322-3AB33-2■■■ 465 624 317 Δ 50.7 2962 94.1 95.4 95.9 0.90 475 6.2 2.2 1LP1322-3AB53-2■■■ 555 744 318 Δ 50.7 3534 94.4 95.6 96.0 0.90 560 6.5 2.1 1LP1322-3AB73-2■■■ 730 979 355 Δ 50.6 4649 94.7 95.9 96.3 0.88 760 5.6 2.1 1LP1322-3BB53-2■■■ 740 992 355 Δ 50.7 4712 94.5 95.8 96.3 0.89 760 5.2 2.0 1LP1322-3BB73-2■■■ 1000 rpm, 6-pole 235 315 315 Y 50.6 2246 93.8 95.0 95.3 0.82 265 6.6 2.1 1LP1322-3AC13-3■■■ 330 443 316 Δ 50.6 3152 93.7 95.0 95.4 0.83 365 6.1 1.9 1LP1322-3AC33-3■■■ 400 536 317 Δ 50.7 3822 93.6 95.0 95.5 0.85 435 5.6 1.7 1LP1322-3AC53-3■■■ 445 597 318 Δ 50.6 4251 93.9 95.1 95.6 0.84 485 5.9 1.7 1LP1322-3AC73-3■■■ 520 697 355 Δ 50.5 4967 94.0 95.2 95.6 0.87 550 6.5 2.0 1LP1322-3BC53-3■■■ 595 798 355 Δ 50.5 5686 94.3 95.5 95.7 0.87 630 7.1 1.7 1LP1322-3BC73-3■■■ 750 rpm, 6-pole 220 295 315 Y 38.2 2802 91.5 93.2 94.1 0.82 250 5.2 1.7 1LP1322-3AC13-4■■■ 300 402 316 Δ 38.2 3820 92.1 93.7 94.5 0.83 335 5.4 1.8 1LP1322-3AC33-4■■■ 320 429 317 Δ 38.2 4076 92.2 93.8 94.6 0.84 355 5.2 1.7 1LP1322-3AC53-4■■■ 345 463 318 Δ 38.2 4394 92.0 93.8 94.7 0.85 380 5.1 1.7 1LP1322-3AC73-4■■■ 420 563 355 Δ 38.0 5349 92.9 94.4 94.9 0.87 445 6.3 1.9 1LP1322-3BC53-4■■■ 460 617 355 Δ 38.0 5857 92.8 94.3 94.9 0.88 485 6.1 1.7 1LP1322-3BC73-4■■■ For versions, see Article No. supplements and special versions 1LP1222-3AC73-4■■■ 9/12 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 690 V, 50 Hz High Efficiency – increased output Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LP1312-3AB13-1... 1LP1312-3AB33-1... 1LP1312-3AB53-1... 1LP1312-3AB73-1... 1LP1312-3BB53-1... 1LP1312-3BB73-1... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3600 3600 3600 3600 3300 3300 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 400 452 560 560 710 710 1LP1312-3AB13-2... 1LP1312-3AB33-2... 1LP1312-3AB53-2... 1LP1312-3AB73-2... 1LP1312-3BB53-2... 1LP1312-3BB73-2... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 320 400 452 560 710 710 1LP1312-3AC13-3... 1LP1312-3AC33-3... 1LP1312-3AC53-3... 1LP1312-3AC73-3... 1LP1312-3BC53-3... 1LP1312-3BC73-3... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 250 320 400 452 560 710 1LP1312-3AC13-4... 1LP1312-3AC33-4... 1LP1312-3AC53-4... 1LP1312-3AC73-4... 1LP1312-3BC53-4... 1LP1312-3BC73-4... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 730 1XB7 730 1XB7 731 1XB7 731 6SL3710-7LG32-6AA3 6SL3710-7LG33-3AA3 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 250 320 320 400 400 452 1LP1322-3AB13-1... 1LP1322-3AB33-1... 1LP1322-3AB53-1... 1LP1322-3AB73-1... 1LP1322-3BB53-1... 1LP1322-3BB73-1... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3600 3600 3600 3600 3300 3300 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH37-4AA3 6SL3710-1GH38-1AA3 6SL3710-1GH38-1AA3 400 452 560 710 790 790 1LP1322-3AB13-2... 1LP1322-3AB33-2... 1LP1322-3AB53-2... 1LP1322-3AB73-2... 1LP1322-3BB53-2... 1LP1322-3BB73-2... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GH33-3AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH35-8AA3 6SL3710-1GH38-1AA3 6SL3710-1GH38-1AA3 320 452 560 560 790 790 1LP1322-3AC13-3... 1LP1322-3AC33-3... 1LP1322-3AC53-3... 1LP1322-3AC73-3... 1LP1322-3BC53-3... 1LP1322-3BC73-3... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GH33-3AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 6SL3710-1GH35-8AA3 6SL3710-1GH37-4AA3 320 400 452 560 560 710 1LP1322-3AC13-4... 1LP1322-3AC33-4... 1LP1322-3AC53-4... 1LP1322-3AC73-4... 1LP1322-3BC53-4... 1LP1322-3BC73-4... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-1GH32-6AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-1AA3 6SL3710-1GH34-7AA3 6SL3710-1GH35-8AA3 250 400 400 400 452 560 Siemens D 81.8 · 04/2014 9 9/13 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency – low noise ■ Selection and ordering data Prated 9 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated T B/ Trated 1LP1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V 3600 rpm, 4-pole 365 489 315 Δ 120.7 969 95.2 95.7 95.3 0.88 520 5.7 1.9 1LP1212-3AB15-5■■■ 455 610 315 Δ 120.6 1207 95.6 96.1 95.7 0.90 630 6.7 2.2 1LP1212-3AB35-5■■■ 1LP1212-3AB55-5■■■ 470 630 315 Δ 120.8 1247 95.6 96.1 95.9 0.90 650 5.8 1.9 540 724 315 Δ 120.7 1433 95.8 96.3 96.1 0.90 750 6.2 2.0 1LP1212-3AB75-5■■■ 3000 rpm, 4-pole 670 898 355 Δ 100.9 2133 95.3 96.3 96.4 0.88 950 4.1 1.5 1LP1212-3BB55-1■■■ 765 1026 355 Δ 100.8 2437 95.7 96.5 96.5 0.89 1080 4.6 1.7 1LP1212-3BB75-1■■■ 1800 rpm, 4-pole 360 483 315 Δ 60.6 1911 94.9 95.9 96.1 0.87 520 6.2 2.2 1LP1212-3AB15-6■■■ 1LP1212-3AB35-6■■■ 440 590 315 Δ 60.6 2335 95.1 96.1 96.3 0.89 620 6.4 2.2 490 657 315 Δ 60.6 2600 95.2 96.2 96.5 0.90 680 6.5 2.3 1LP1212-3AB55-6■■■ 1LP1212-3AB75-6■■■ 620 831 315 Δ 60.5 3290 95.7 96.5 96.7 0.90 860 7.8 2.2 795 1066 355 Δ 60.6 4219 95.4 96.4 96.7 0.89 1120 5.8 2.2 1LP1212-3BB55-6■■■ 1LP1212-3BB75-6■■■ 805 1080 355 Δ 60.7 4272 95.3 96.4 96.7 0.89 1120 5.4 2.0 1200 rpm, 6-pole 310 416 315 Δ 60.7 2468 94.3 95.5 95.9 0.82 475 5.7 1.7 1LP1212-3AC15-7■■■ 1LP1212-3AC35-7■■■ 380 510 315 Δ 60.7 3026 94.6 95.7 96.0 0.84 570 5.8 1.8 450 603 315 Δ 60.6 3582 95.0 96.0 96.2 0.84 670 6.4 1.9 1LP1212-3AC55-7■■■ 1LP1212-3AC75-7■■■ 475 637 315 Δ 60.6 3781 95.0 96.0 96.3 0.84 710 6.2 1.9 625 838 355 Δ 60.5 4975 95.0 96.0 96.1 0.86 910 7.1 2.0 1LP1212-3BC55-7■■■ 685 919 355 Δ 60.5 5453 95.1 96.0 96.2 0.87 990 7.0 1.8 1LP1212-3BC75-7■■■ 900 rpm, 6-pole 270 362 315 Δ 45.7 2865 93.4 94.7 95.3 0.82 420 5.6 1.8 1LP1212-3AC15-8■■■ 1LP1212-3AC35-8■■■ 340 456 315 Δ 45.6 3609 93.9 95.1 95.5 0.82 520 6.2 2.0 360 483 315 Δ 45.7 3821 93.7 95.0 95.5 0.85 540 5.6 1.8 1LP1212-3AC55-8■■■ 395 530 315 Δ 45.6 4193 93.9 95.2 95.6 0.85 590 5.8 1.8 1LP1212-3AC75-8■■■ 1LP1212-3BC55-8■■■ 490 657 355 Δ 45.6 5202 93.7 95.0 95.5 0.87 710 6.0 1.9 560 751 355 Δ 45.6 5944 93.9 95.2 95.6 0.87 810 6.1 1.7 1LP1212-3BC75-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V 3600 rpm, 4-pole 370 496 315 Δ 120.7 982 95.3 95.8 95.3 0.88 580 5.9 2.0 1LP1222-3AB15-5■■■ 1LP1222-3AB35-5■■■ 435 583 315 Δ 120.7 1154 95.5 96.0 95.7 0.89 670 5.7 1.9 485 650 315 Δ 120.7 1287 95.7 96.2 95.9 0.90 740 6.4 2.1 1LP1222-3AB55-5■■■ 560 751 315 Δ 120.6 1486 95.9 96.4 96.1 0.91 840 7.3 2.4 1LP1222-3AB75-5■■■ 3000 rpm, 4-pole 695 932 355 Δ 100.8 2214 95.6 96.5 96.5 0.88 1080 4.5 1.6 1LP1222-3BB55-1■■■ 700 939 355 Δ 100.9 2229 95.4 96.4 96.5 0.88 1080 4.2 1.5 1LP1222-3BB75-1■■■ 1800 rpm, 4-pole 360 483 315 Δ 60.6 1911 94.9 95.9 96.1 0.87 570 6.2 2.2 1LP1222-3AB15-6■■■ 445 597 315 Δ 60.6 2362 95.1 96.1 96.3 0.89 680 6.6 2.3 1LP1222-3AB35-6■■■ 500 671 315 Δ 60.6 2654 95.3 96.3 96.5 0.90 760 6.8 2.4 1LP1222-3AB55-6■■■ 580 778 315 Δ 60.6 3077 95.4 96.4 96.6 0.90 880 6.9 2.4 1LP1222-3AB75-6■■■ 735 986 355 Δ 60.7 3901 95.2 96.3 96.6 0.89 1120 5.2 1.9 1LP1222-3BB55-6■■■ 850 1140 355 Δ 60.6 4510 95.5 96.5 96.8 0.89 1300 5.8 2.2 1LP1222-3BB75-6■■■ 1200 rpm, 6-pole 330 443 315 Δ 60.6 2627 94.7 95.7 96.0 0.82 550 6.2 1.9 1LP1222-3AC15-7■■■ 395 530 315 Δ 60.7 3145 94.7 95.8 96.1 0.83 650 6.0 1.8 1LP1222-3AC35-7■■■ 435 583 315 Δ 60.6 3463 94.9 96.0 96.2 0.84 710 6.3 1.9 1LP1222-3AC55-7■■■ 490 657 315 Δ 60.6 3901 95.0 96.0 96.3 0.85 790 6.0 1.8 1LP1222-3AC75-7■■■ 615 825 355 Δ 60.5 4895 95.0 96.0 96.1 0.86 980 7.1 2.0 1LP1222-3BC55-7■■■ 685 919 355 Δ 60.5 5453 95.1 96.1 96.2 0.87 1080 7.0 1.8 1LP1222-3BC75-7■■■ 900 rpm, 6-pole 265 355 315 Δ 45.6 2814 93.5 94.7 95.2 0.80 460 5.9 1.9 1LP1222-3AC15-8■■■ 1LP1222-3AC35-8■■■ 330 443 315 Δ 45.7 3502 93.7 94.9 95.4 0.83 550 5.8 1.9 360 483 315 Δ 45.6 3821 93.8 95.1 95.6 0.84 590 5.8 1.8 1LP1222-3AC55-8■■■ 395 530 315 Δ 45.7 4193 93.8 95.1 95.6 0.85 640 5.5 1.7 1LP1222-3AC75-8■■■ 500 671 355 Δ 45.5 5307 93.9 95.1 95.5 0.87 790 6.3 1.9 1LP1222-3BC55-8■■■ 575 771 355 Δ 45.5 6102 94.1 95.3 95.6 0.87 910 6.6 1.6 1LP1222-3BC75-8■■■ For versions, see Article No. supplements and special versions 1LP1222-3AC75-8■■■ 9/14 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency – low noise Motor type mIM B3 mIM V1 J LpfA, LWA, Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 tolerance +3 dB(A) no-load Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LP1212-3AB15-5... 1LP1212-3AB35-5... 1LP1212-3AB55-5... 1LP1212-3AB75-5... 1280 1470 1640 1800 1330 1520 1690 1850 3.3 4.2 4.8 5.7 79 79 79 79 94.5 94.5 94.5 94.5 3600 3600 3600 3600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 590 725 725 820 1LP1212-3BB55-1... 1LP1212-3BB75-1... 2260 2380 2310 2440 8.0 8.7 79 79 95 95 3300 3300 1XB7 740 6SL3710-7LE41-0AA3 2 x 1XB7 740 6SL3710-7LE41-2AA3 960 1230 1LP1212-3AB15-6... 1LP1212-3AB35-6... 1LP1212-3AB55-6... 1LP1212-3AB75-6... 1LP1212-3BB55-6... 1LP1212-3BB75-6... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 6SL3710-7LE41-2AA3 590 725 725 960 1230 1230 1LP1212-3AC15-7... 1LP1212-3AC35-7... 1LP1212-3AC55-7... 1LP1212-3AC75-7... 1LP1212-3BC55-7... 1LP1212-3BC75-7... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE37-5AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 477 590 725 725 960 1230 1LP1212-3AC15-8... 1LP1212-3AC35-8... 1LP1212-3AC55-8... 1LP1212-3AC75-8... 1LP1212-3BC55-8... 1LP1212-3BC75-8... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 477 590 590 590 725 820 1LP1222-3AB15-5... 1LP1222-3AB35-5... 1LP1222-3AB55-5... 1LP1222-3AB75-5... 1280 1470 1640 1800 1330 1520 1690 1850 3.3 4.2 4.8 5.7 79 79 79 79 94.5 94.5 94.5 94.5 3600 3600 3600 3600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 590 725 820 960 1LP1222-3BB55-1... 1LP1222-3BB75-1... 2260 2380 2310 2440 8.0 8.7 79 79 95 95 3300 3300 2 x 1XB7 740 6SL3710-2GE41-1AA3 2 x 1XB7 740 6SL3710-2GE41-1AA3 1092 1092 1LP1222-3AB15-6... 1LP1222-3AB35-6... 1LP1222-3AB55-6... 1LP1222-3AB75-6... 1LP1222-3BB55-6... 1LP1222-3BB75-6... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-4AA3 6SL3710-2GE41-4AA3 590 725 820 960 1340 1340 1LP1222-3AC15-7... 1LP1222-3AC35-7... 1LP1222-3AC55-7... 1LP1222-3AC75-7... 1LP1222-3BC55-7... 1LP1222-3BC75-7... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-1AA3 590 725 725 820 1092 1092 1LP1222-3AC15-8... 1LP1222-3AC35-8... 1LP1222-3AC55-8... 1LP1222-3AC75-8... 1LP1222-3BC55-8... 1LP1222-3BC75-8... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE35-0AA3 6SL3710-1GE36-1AA3 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 477 590 590 725 820 960 Siemens D 81.8 · 04/2014 9 9/15 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency – increased output ■ Selection and ordering data Prated 9 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated T B/ Trated 1LP1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V 3600 rpm, 4-pole 415 557 315 Δ 120.8 1102 95.0 95.7 95.5 0.88 590 5.0 1.7 1LP1312-3AB15-5■■■ 525 704 316 Δ 120.8 1393 95.5 96.1 95.9 0.89 740 5.7 1.9 1LP1312-3AB35-5■■■ 1LP1312-3AB55-5■■■ 540 724 317 Δ 120.9 1434 95.4 96.1 96.0 0.89 760 5.0 1.6 620 831 318 Δ 120.8 1646 95.6 96.3 96.2 0.90 860 5.4 1.7 1LP1312-3AB75-5■■■ 3000 rpm, 4-pole 705 945 355 Δ 100.9 2245 95.2 96.2 96.4 0.87 1020 3.8 1.4 1LP1312-3BB55-1■■■ 810 1086 355 Δ 100.8 2579 95.6 96.5 96.6 0.88 1140 4.4 1.6 1LP1312-3BB75-1■■■ 1800 rpm, 4-pole 405 543 315 Δ 60.7 2149 94.4 95.6 95.9 0.88 580 5.5 2.0 1LP1312-3AB15-6■■■ 1LP1312-3AB35-6■■■ 495 664 316 Δ 60.7 2627 94.6 95.7 96.1 0.89 700 5.7 2.0 550 738 317 Δ 60.7 2919 94.8 95.9 96.3 0.90 770 5.8 2.0 1LP1312-3AB55-6■■■ 1LP1312-3AB75-6■■■ 705 945 318 Δ 60.6 3741 95.3 96.3 96.6 0.90 980 6.9 2.0 840 1126 355 Δ 60.6 4457 95.3 96.3 96.6 0.89 1180 5.5 2.0 1LP1312-3BB55-6■■■ 1LP1312-3BB75-6■■■ 850 1140 355 Δ 60.7 4511 95.1 96.3 96.6 0.89 1200 5.0 1.9 1200 rpm, 6-pole 340 456 315 Δ 60.8 2708 93.8 95.2 95.7 0.82 520 5.2 1.6 1LP1312-3AC15-7■■■ 1LP1312-3AC35-7■■■ 415 557 316 Δ 60.7 3305 94.1 95.4 95.9 0.84 620 5.4 1.6 495 664 317 Δ 60.7 3941 94.6 95.8 96.1 0.84 740 5.8 1.8 1LP1312-3AC55-7■■■ 1LP1312-3AC75-7■■■ 525 704 318 Δ 60.7 4180 94.6 95.7 96.1 0.85 780 5.7 1.7 650 872 355 Δ 60.5 5174 94.9 95.9 96.1 0.86 950 6.8 1.9 1LP1312-3BC55-7■■■ 710 952 355 Δ 60.5 5651 95.0 96.0 96.1 0.87 1020 6.8 1.8 1LP1312-3BC75-7■■■ 900 rpm, 6-pole 295 396 315 Δ 45.8 3131 92.8 94.3 95.0 0.82 460 5.1 1.6 1LP1312-3AC15-8■■■ 1LP1312-3AC35-8■■■ 370 496 316 Δ 45.7 3926 93.4 94.8 95.3 0.82 570 5.6 1.8 395 530 317 Δ 45.7 4195 93.1 94.6 95.3 0.85 590 5.1 1.6 1LP1312-3AC55-8■■■ 435 583 318 Δ 45.7 4618 93.3 94.8 95.4 0.85 650 5.2 1.6 1LP1312-3AC75-8■■■ 1LP1312-3BC55-8■■■ 505 677 355 Δ 45.6 5360 93.6 94.9 95.4 0.87 740 5.7 1.8 570 764 355 Δ 45.6 6049 93.8 95.1 95.5 0.88 820 6.0 1.6 1LP1312-3BC75-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V 3600 rpm, 4-pole 425 570 315 Δ 120.8 1128 95.1 95.7 95.5 0.88 660 5.2 1.7 1LP1322-3AB15-5■■■ 1LP1322-3AB35-5■■■ 495 664 316 Δ 120.9 1314 95.3 96.0 95.8 0.89 760 5.0 1.6 560 751 317 Δ 120.8 1486 95.6 96.2 96.0 0.90 850 5.6 1.8 1LP1322-3AB55-5■■■ 650 872 318 Δ 120.7 1725 95.8 96.4 96.2 0.91 970 6.3 2.0 1LP1322-3AB75-5■■■ 3000 rpm, 4-pole 735 986 355 Δ 100.8 2340 95.5 96.4 96.5 0.88 1140 4.2 1.5 1LP1322-3BB55-1■■■ 745 999 355 Δ 100.9 2372 95.3 96.3 96.5 0.88 1160 3.9 1.4 1LP1322-3BB75-1■■■ 1800 rpm, 4-pole 400 536 315 Δ 60.7 2123 94.4 95.6 95.9 0.88 620 5.7 2.0 1LP1322-3AB15-6■■■ 500 671 316 Δ 60.7 2654 94.7 95.8 96.2 0.89 770 5.8 2.0 1LP1322-3AB35-6■■■ 565 758 317 Δ 60.7 2999 94.9 96.0 96.3 0.90 860 6.0 2.1 1LP1322-3AB55-6■■■ 650 872 318 Δ 60.7 3449 95.0 96.1 96.4 0.91 980 6.2 2.1 1LP1322-3AB75-6■■■ 770 1033 355 Δ 60.7 4087 95.0 96.2 96.6 0.89 1180 5.0 1.8 1LP1322-3BB55-6■■■ 895 1200 355 Δ 60.6 4749 95.4 96.4 96.7 0.89 1360 5.6 2.1 1LP1322-3BB75-6■■■ 1200 rpm, 6-pole 360 483 315 Δ 60.7 2866 94.3 95.4 95.8 0.82 600 5.7 1.7 1LP1322-3AC15-7■■■ 425 570 316 Δ 60.7 3385 94.3 95.5 95.9 0.83 700 5.6 1.7 1LP1322-3AC35-7■■■ 480 644 317 Δ 60.7 3822 94.5 95.7 96.0 0.84 780 5.7 1.7 1LP1322-3AC55-7■■■ 535 717 318 Δ 60.7 4261 94.6 95.8 96.1 0.85 860 5.5 1.7 1LP1322-3AC75-7■■■ 635 852 355 Δ 60.5 5054 94.9 96.0 96.1 0.86 1000 6.9 2.0 1LP1322-3BC55-7■■■ 710 952 355 Δ 60.5 5652 95.0 96.0 96.2 0.87 1120 6.7 1.8 1LP1322-3BC75-7■■■ 900 rpm, 6-pole 290 389 315 Δ 45.7 3077 92.9 94.4 95.0 0.81 500 5.4 1.8 1LP1322-3AC15-8■■■ 1LP1322-3AC35-8■■■ 360 483 316 Δ 45.7 3821 93.1 94.6 95.2 0.83 600 5.3 1.7 395 530 317 Δ 45.7 4193 93.2 94.7 95.3 0.84 650 5.3 1.7 1LP1322-3AC55-8■■■ 430 577 318 Δ 45.7 4567 93.2 94.7 95.4 0.85 700 5.0 1.6 1LP1322-3AC75-8■■■ 515 691 355 Δ 45.6 5466 93.7 95.0 95.5 0.87 820 6.0 1.8 1LP1322-3BC55-8■■■ 595 798 355 Δ 45.5 6315 94.0 95.2 95.6 0.87 940 6.4 1.6 1LP1322-3BC75-8■■■ For versions, see Article No. supplements and special versions 1LP1222-3AC75-8■■■ 9/16 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 460 V, 60 Hz High Efficiency – increased output Motor type mIM B3 mIM V1 J LpfA, LWA, Terminal box tolerance +3 dB(A) no-load Mech. speed limit IM B3 tolerance +3 dB(A) no-load Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LP1312-3AB15-5... 1LP1312-3AB35-5... 1LP1312-3AB55-5... 1LP1312-3AB75-5... 1280 1470 1640 1800 1330 1520 1690 1850 3.3 4.2 4.8 5.7 85 85 85 85 100.5 100.5 100.5 100.5 3600 3600 3600 3600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE38-4AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 590 820 820 960 1LP1312-3BB55-1... 1LP1312-3BB75-1... 2260 2380 2310 2440 8.0 8.7 85 85 101 101 3300 3300 1XB7 740 6SL3710-7LE41-2AA3 2 x 1XB7 740 6SL3710-7LE41-2AA3 1230 1230 1LP1312-3AB15-6... 1LP1312-3AB35-6... 1LP1312-3AB55-6... 1LP1312-3AB75-6... 1LP1312-3BB55-6... 1LP1312-3BB75-6... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-2AA3 6SL3710-7LE41-2AA3 6SL3710-7LE41-2AA3 590 725 820 1230 1230 1230 1LP1312-3AC15-7... 1LP1312-3AC35-7... 1LP1312-3AC55-7... 1LP1312-3AC75-7... 1LP1312-3BC55-7... 1LP1312-3BC75-7... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE38-4AA3 6SL3710-7LE41-0AA3 6SL3710-7LE41-2AA3 590 725 820 820 960 1230 1LP1312-3AC15-8... 1LP1312-3AC35-8... 1LP1312-3AC55-8... 1LP1312-3AC75-8... 1LP1312-3BC55-8... 1LP1312-3BC75-8... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LE35-0AA3 6SL3710-7LE36-1AA3 6SL3710-7LE36-1AA3 6SL3710-7LE37-5AA3 6SL3710-7LE38-4AA3 6SL3710-7LE38-4AA3 477 590 590 725 820 820 1LP1322-3AB15-5... 1LP1322-3AB35-5... 1LP1322-3AB55-5... 1LP1322-3AB75-5... 1280 1470 1640 1800 1330 1520 1690 1850 3.3 4.2 4.8 5.7 85 85 85 85 100.5 100.5 100.5 100.5 3600 3600 3600 3600 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 725 820 960 1092 1LP1322-3BB55-1... 1LP1322-3BB75-1... 2260 2380 2310 2440 8.0 8.7 85 85 101 101 3300 3300 2 x 1XB7 740 6SL3710-2GE41-4AA3 2 x 1XB7 740 6SL3710-2GE41-4AA3 1340 1340 1LP1322-3AB15-6... 1LP1322-3AB35-6... 1LP1322-3AB55-6... 1LP1322-3AB75-6... 1LP1322-3BB55-6... 1LP1322-3BB75-6... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 2 x 1XB7 740 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-6AA3 6SL3710-2GE41-6AA3 725 820 960 1092 1340 1516 1LP1322-3AC15-7... 1LP1322-3AC35-7... 1LP1322-3AC55-7... 1LP1322-3AC75-7... 1LP1322-3BC55-7... 1LP1322-3BC75-7... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 2 x 1XB7 740 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 6SL3710-2GE41-1AA3 6SL3710-2GE41-4AA3 725 725 820 960 1092 1340 1LP1322-3AC15-8... 1LP1322-3AC35-8... 1LP1322-3AC55-8... 1LP1322-3AC75-8... 1LP1322-3BC55-8... 1LP1322-3BC75-8... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GE36-1AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE37-5AA3 6SL3710-1GE38-4AA3 6SL3710-1GE41-0AA3 590 725 725 725 820 960 Siemens D 81.8 · 04/2014 9 9/17 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency – low noise ■ Selection and ordering data Prated 9 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated T B/ Trated 1LP1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V 3600 rpm, 4-pole 340 456 315 Δ 120.8 902 95.0 95.5 95.1 0.88 385 5.5 1.8 1LP1212-3AB16-5■■■ 440 590 315 Δ 120.6 1168 95.5 96.0 95.6 0.90 480 6.7 2.2 1LP1212-3AB36-5■■■ 1LP1212-3AB56-5■■■ 480 644 315 Δ 120.6 1274 95.7 96.2 95.8 0.90 520 7.1 2.3 550 738 315 Δ 120.6 1459 95.8 96.3 96.0 0.91 590 7.4 2.3 1LP1212-3AB76-5■■■ 3000 rpm, 4-pole 635 852 355 Δ 100.9 2022 95.2 96.2 96.3 0.88 710 4.2 1.5 1LP1212-3BB56-1■■■ 720 966 355 Δ 100.8 2292 95.4 96.4 96.4 0.89 790 4.5 1.6 1LP1212-3BB76-1■■■ 1800 rpm, 4-pole 325 436 315 Δ 60.6 1725 94.7 95.7 96.0 0.88 365 6.3 2.2 1LP1212-3AB16-6■■■ 1LP1212-3AB36-6■■■ 430 577 315 Δ 60.6 2282 95.2 96.1 96.3 0.88 480 7.4 2.6 465 624 315 Δ 60.6 2468 95.3 96.2 96.4 0.90 510 7.4 2.6 1LP1212-3AB56-6■■■ 1LP1212-3AB76-6■■■ 570 764 315 Δ 60.5 3024 95.6 96.5 96.6 0.89 630 8.2 2.4 760 1019 355 Δ 60.6 4034 95.3 96.3 96.6 0.89 840 5.9 2.2 1LP1212-3BB56-6■■■ 1LP1212-3BB76-6■■■ 845 1133 355 Δ 60.5 4484 95.5 96.5 96.7 0.89 930 6.4 2.2 1200 rpm, 6-pole 295 396 315 Δ 60.6 2348 94.5 95.5 95.8 0.82 355 6.5 2.0 1LP1212-3AC16-7■■■ 1LP1212-3AC36-7■■■ 365 489 315 Δ 60.6 2907 94.7 95.7 96.0 0.83 435 6.5 2.0 395 530 315 Δ 60.6 3147 94.8 95.8 96.1 0.84 465 6.4 2.0 1LP1212-3AC56-7■■■ 1LP1212-3AC76-7■■■ 440 590 315 Δ 60.6 3504 94.9 95.9 96.2 0.85 510 6.6 2.0 590 791 355 Δ 60.4 4697 95.1 96.0 96.0 0.86 680 8.0 2.1 1LP1212-3BC56-7■■■ 650 872 355 Δ 60.5 5176 95.0 96.0 96.1 0.87 740 7.6 1.9 1LP1212-3BC76-7■■■ 900 rpm, 6-pole 240 322 315 Y 45.6 2549 93.2 94.5 95.0 0.81 295 6.0 1.9 1LP1212-3AC16-8■■■ 1LP1212-3AC36-8■■■ 320 429 315 Δ 45.6 3397 93.8 95.0 95.4 0.82 390 6.3 2.0 335 449 315 Δ 45.6 3557 93.8 95.1 95.5 0.84 395 6.2 2.0 1LP1212-3AC56-8■■■ 375 503 315 Δ 45.6 3981 94.0 95.2 95.6 0.84 445 6.5 1.9 1LP1212-3AC76-8■■■ 1LP1212-3BC56-8■■■ 470 630 355 Δ 45.5 4987 93.8 95.1 95.4 0.87 540 6.7 2.0 525 704 355 Δ 45.5 5572 93.9 95.2 95.5 0.87 600 6.7 1.8 1LP1212-3BC76-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V 3600 rpm, 4-pole 345 463 315 Δ 120.6 916 95.2 95.6 95.2 0.89 425 6.6 2.2 1LP1222-3AB16-5■■■ 1LP1222-3AB36-5■■■ 420 563 315 Δ 120.6 1114 95.5 96.0 95.5 0.90 510 7.2 2.4 465 624 315 Δ 120.5 1234 95.7 96.1 95.7 0.90 560 7.8 2.5 1LP1222-3AB56-5■■■ 505 677 315 Δ 120.7 1340 95.7 96.2 95.9 0.91 610 6.4 2.1 1LP1222-3AB76-5■■■ 3000 rpm, 4-pole 640 858 355 Δ 100.8 2038 95.3 96.2 96.3 0.88 790 4.3 1.5 1LP1222-3BB56-1■■■ 720 966 355 Δ 100.8 2293 95.5 96.4 96.4 0.89 880 4.8 1.7 1LP1222-3BB76-1■■■ 1800 rpm, 4-pole 315 422 315 Δ 60.7 1672 94.6 95.6 95.9 0.88 395 6.0 2.1 1LP1222-3AB16-6■■■ 415 557 315 Δ 60.6 2202 95.2 96.1 96.2 0.89 510 7.4 2.6 1LP1222-3AB36-6■■■ 460 617 315 Δ 60.6 2441 95.3 96.2 96.4 0.90 560 7.4 2.5 1LP1222-3AB56-6■■■ 570 764 315 Δ 60.5 3025 95.7 96.5 96.6 0.89 700 8.4 2.4 1LP1222-3AB76-6■■■ 760 1019 355 Δ 60.6 4033 95.3 96.4 96.6 0.89 930 6.1 2.3 1LP1222-3BB56-6■■■ 775 1039 355 Δ 60.6 4113 95.2 96.3 96.6 0.89 950 5.5 2.1 1LP1222-3BB76-6■■■ 1200 rpm, 6-pole 280 375 315 Δ 60.7 2229 94.1 95.3 95.7 0.83 370 6.0 1.8 1LP1222-3AC16-7■■■ 360 483 315 Δ 60.6 2868 94.7 95.7 96.0 0.83 475 6.5 2.0 1LP1222-3AC36-7■■■ 395 530 315 Δ 60.6 3146 94.8 95.8 96.1 0.84 520 6.4 2.0 1LP1222-3AC56-7■■■ 445 597 315 Δ 60.6 3544 94.9 96.0 96.2 0.85 570 6.8 2.0 1LP1222-3AC76-7■■■ 570 764 355 Δ 60.5 4539 95.0 95.9 96.0 0.86 730 7.6 2.2 1LP1222-3BC56-7■■■ 650 872 355 Δ 60.4 5175 95.2 96.0 96.0 0.86 830 8.2 1.9 1LP1222-3BC76-7■■■ 900 rpm, 6-pole 245 329 315 Δ 45.6 2602 93.4 94.6 95.1 0.80 340 6.3 2.1 1LP1222-3AC16-8■■■ 1LP1222-3AC36-8■■■ 310 416 315 Δ 45.6 3293 93.7 95.0 95.3 0.81 425 6.5 2.1 340 456 315 Δ 45.6 3611 93.8 95.1 95.5 0.83 450 6.4 2.0 1LP1222-3AC56-8■■■ 375 503 315 Δ 45.6 3981 94.0 95.2 95.6 0.84 490 6.5 1.9 1LP1222-3AC76-8■■■ 465 624 355 Δ 45.5 4935 93.8 95.1 95.4 0.87 590 6.7 2.0 1LP1222-3BC56-8■■■ 520 697 355 Δ 45.5 5518 93.9 95.1 95.5 0.87 660 6.8 1.8 1LP1222-3BC76-8■■■ For versions, see Article No. supplements and special versions 1LP1222-3AC76-8■■■ 9/18 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency – low noise Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LP1212-3AB16-5... 1LP1212-3AB36-5... 1LP1212-3AB56-5... 1LP1212-3AB76-5... 1280 1470 1640 1800 1330 1520 1690 1850 3.3 4.2 4.8 5.7 79 79 79 79 94.5 94.5 94.5 94.5 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 731 1XB7 731 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 400 560 560 710 1LP1212-3BB56-1... 1LP1212-3BB76-1... 2260 2380 2310 2440 8.0 8.7 79 79 95 95 3300 3300 1XB7 740 1XB7 740 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 710 790 1LP1212-3AB16-6... 1LP1212-3AB36-6... 1LP1212-3AB56-6... 1LP1212-3AB76-6... 1LP1212-3BB56-6... 1LP1212-3BB76-6... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-8AA3 6SL3710-7LG41-0AA3 400 560 560 710 880 1000 1LP1212-3AC16-7... 1LP1212-3AC36-7... 1LP1212-3AC56-7... 1LP1212-3AC76-7... 1LP1212-3BC56-7... 1LP1212-3BC76-7... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 400 452 560 560 710 790 1LP1212-3AC16-8... 1LP1212-3AC36-8... 1LP1212-3AC56-8... 1LP1212-3AC76-8... 1LP1212-3BC56-8... 1LP1212-3BC76-8... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-7LG33-3AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-1AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 320 400 400 452 560 710 1LP1222-3AB16-5... 1LP1222-3AB36-5... 1LP1222-3AB56-5... 1LP1222-3AB76-5... 1280 1470 1640 1800 1330 1520 1690 1850 3.3 4.2 4.8 5.7 79 79 79 79 94.5 94.5 94.5 94.5 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 452 560 560 710 1LP1222-3BB56-1... 1LP1222-3BB76-1... 2260 2380 2310 2440 8.0 8.7 79 79 95 95 3300 3300 1XB7 740 1XB7 740 6SL3710-1GF38-1AA3 6SL3710-2GF41-1AA3 790 1036 1LP1222-3AB16-6... 1LP1222-3AB36-6... 1LP1222-3AB56-6... 1LP1222-3AB76-6... 1LP1222-3BB56-6... 1LP1222-3BB76-6... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GF34-1AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-2GF41-1AA3 6SL3710-2GF41-1AA3 400 560 560 710 1036 1036 1LP1222-3AC16-7... 1LP1222-3AC36-7... 1LP1222-3AC56-7... 1LP1222-3AC76-7... 1LP1222-3BC56-7... 1LP1222-3BC76-7... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GF34-1AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF38-1AA3 6SL3710-2GF38-6AA3 400 560 560 710 790 836 1LP1222-3AC16-8... 1LP1222-3AC36-8... 1LP1222-3AC56-8... 1LP1222-3AC76-8... 1LP1222-3BC56-8... 1LP1222-3BC76-8... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 79 79 79 79 79 79 94.5 94.5 94.5 94.5 95 95 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 400 452 452 560 710 710 Siemens D 81.8 · 04/2014 9 9/19 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency – increased output ■ Selection and ordering data Prated 9 Prated Operating values at rated output Frame Con- frated Trated ηrated, ηrated, size nec5/4 4/4 tion ηrated, cosϕrated, Irated 3/4 4/4 ILR/ Irated T B/ Trated 1LP1 cast-iron series specially designed for converter-fed operation kW hp FS Hz Nm % % % A Article No. • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V 3600 rpm, 4-pole 385 516 315 Δ 120.9 1022 94.7 95.4 95.3 0.88 435 4.8 1.6 1LP1312-3AB16-5■■■ 505 677 316 Δ 120.7 1340 95.4 96.0 95.8 0.89 560 5.8 1.9 1LP1312-3AB36-5■■■ 1LP1312-3AB56-5■■■ 560 751 317 Δ 120.7 1486 95.5 96.1 95.9 0.90 610 6.1 2.0 640 858 318 Δ 120.7 1699 95.7 96.3 96.1 0.91 690 6.3 2.0 1LP1312-3AB76-5■■■ 3000 rpm, 4-pole 680 912 355 Δ 100.9 2165 95.0 96.1 96.3 0.87 770 3.8 1.4 1LP1312-3BB56-1■■■ 760 1019 355 Δ 100.9 2420 95.3 96.3 96.4 0.88 850 4.2 1.5 1LP1312-3BB76-1■■■ 1800 rpm, 4-pole 355 476 315 Δ 60.7 1885 94.2 95.4 95.8 0.88 400 5.7 2.0 1LP1312-3AB16-6■■■ 1LP1312-3AB36-6■■■ 485 650 316 Δ 60.6 2574 94.8 95.9 96.1 0.89 540 6.6 2.3 530 711 317 Δ 60.6 2813 94.9 95.9 96.3 0.90 580 6.5 2.2 1LP1312-3AB56-6■■■ 1LP1312-3AB76-6■■■ 655 878 318 Δ 60.6 3476 95.2 96.2 96.5 0.90 720 7.2 2.1 800 1073 355 Δ 60.6 4245 95.1 96.2 96.5 0.89 880 5.6 2.1 1LP1312-3BB56-6■■■ 1LP1312-3BB76-6■■■ 895 1200 355 Δ 60.6 4750 95.3 96.4 96.6 0.89 990 6.0 2.1 1200 rpm, 6-pole 325 436 315 Δ 60.7 2587 94.0 95.2 95.6 0.82 395 5.8 1.8 1LP1312-3AC16-7■■■ 1LP1312-3AC36-7■■■ 400 536 316 Δ 60.7 3184 94.3 95.4 95.8 0.83 480 5.9 1.8 440 590 317 Δ 60.7 3504 94.3 95.5 95.9 0.84 520 5.7 1.7 1LP1312-3AC56-7■■■ 1LP1312-3AC76-7■■■ 485 650 318 Δ 60.6 3861 94.5 95.6 96.0 0.85 560 6.0 1.8 615 825 355 Δ 60.5 4897 95.0 95.9 96.0 0.86 710 7.7 2.0 1LP1312-3BC56-7■■■ 675 905 355 Δ 60.5 5374 94.9 95.9 96.0 0.87 770 7.3 1.8 1LP1312-3BC76-7■■■ 900 rpm, 6-pole 260 349 315 Y 45.7 2759 92.6 94.1 94.8 0.82 320 5.5 1.8 1LP1312-3AC16-8■■■ 1LP1312-3AC36-8■■■ 350 469 316 Δ 45.7 3714 93.3 94.6 95.2 0.82 425 5.8 1.9 375 503 317 Δ 45.7 3981 93.2 94.6 95.3 0.84 445 5.5 1.8 1LP1312-3AC56-8■■■ 415 557 318 Δ 45.6 4407 93.5 94.8 95.3 0.84 495 5.9 1.7 1LP1312-3AC76-8■■■ 1LP1312-3BC56-8■■■ 485 650 355 Δ 45.5 5148 93.7 95.0 95.4 0.87 560 6.5 1.9 545 731 355 Δ 45.5 5784 93.8 95.1 95.5 0.87 620 6.5 1.7 1LP1312-3BC76-8■■■ • Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F) • Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V 3600 rpm, 4-pole 400 536 315 Δ 120.8 1062 95.1 95.6 95.4 0.88 500 5.6 1.9 1LP1322-3AB16-5■■■ 1LP1322-3AB36-5■■■ 490 657 316 Δ 120.7 1300 95.4 96.0 95.7 0.90 600 6.1 2.0 550 738 317 Δ 120.7 1460 95.6 96.2 95.9 0.90 670 6.5 2.1 1LP1322-3AB56-5■■■ 585 784 318 Δ 120.8 1553 95.5 96.2 96.0 0.90 710 5.5 1.8 1LP1322-3AB76-5■■■ 3000 rpm, 4-pole 670 898 355 Δ 100.9 2133 95.1 96.2 96.3 0.88 830 4.1 1.5 1LP1322-3BB56-1■■■ 765 1026 355 Δ 100.8 2438 95.4 96.4 96.4 0.89 940 4.5 1.6 1LP1322-3BB76-1■■■ 1800 rpm, 4-pole 340 456 315 Δ 60.7 1804 94.2 95.4 95.8 0.88 425 5.6 2.0 1LP1322-3AB16-6■■■ 470 630 316 Δ 60.6 2495 94.7 95.8 96.1 0.89 580 6.5 2.3 1LP1322-3AB36-6■■■ 525 704 317 Δ 60.7 2786 94.8 95.9 96.3 0.90 640 6.4 2.2 1LP1322-3AB56-6■■■ 655 878 318 Δ 60.6 3475 95.3 96.2 96.5 0.90 790 7.5 2.1 1LP1322-3AB76-6■■■ 805 1080 355 Δ 60.6 4272 95.2 96.3 96.6 0.89 990 5.7 2.1 1LP1322-3BB56-6■■■ 820 1100 355 Δ 60.7 4352 95.0 96.2 96.5 0.89 1000 5.3 2.0 1LP1322-3BB76-6■■■ 1200 rpm, 6-pole 300 402 315 Δ 60.7 2389 93.7 95.0 95.5 0.83 400 5.5 1.7 1LP1322-3AC16-7■■■ 395 530 316 Δ 60.7 3145 94.2 95.4 95.8 0.83 520 6.0 1.8 1LP1322-3AC36-7■■■ 435 583 317 Δ 60.7 3464 94.3 95.5 95.9 0.84 570 5.8 1.8 1LP1322-3AC56-7■■■ 490 657 318 Δ 60.6 3901 94.5 95.7 96.0 0.85 630 6.1 1.8 1LP1322-3AC76-7■■■ 590 791 355 Δ 60.5 4698 94.9 95.9 96.0 0.86 750 7.4 2.1 1LP1322-3BC56-7■■■ 675 905 355 Δ 60.4 5374 95.1 96.0 96.0 0.86 860 7.9 1.8 1LP1322-3BC76-7■■■ 900 rpm, 6-pole 270 362 315 Δ 45.7 2865 92.8 94.2 94.8 0.81 370 5.8 1.9 1LP1322-3AC16-8■■■ 1LP1322-3AC36-8■■■ 330 443 316 Δ 45.6 3504 93.4 94.7 95.1 0.82 445 6.2 2.0 375 503 317 Δ 45.6 3980 93.3 94.6 95.2 0.84 495 5.8 1.8 1LP1322-3AC56-8■■■ 410 550 318 Δ 45.6 4353 93.4 94.8 95.3 0.84 540 5.9 1.7 1LP1322-3AC76-8■■■ 480 644 355 Δ 45.5 5094 93.7 95.0 95.4 0.87 610 6.5 1.9 1LP1322-3BC56-8■■■ 540 724 355 Δ 45.5 5731 93.8 95.1 95.4 0.87 690 6.5 1.7 1LP1322-3BC76-8■■■ For versions, see Article No. supplements and special versions 1LP1222-3AC76-8■■■ 9/20 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Forced-air cooled motors — open version 1LP1 motors for converter-fed operation Line voltage 575 V, 60 Hz High Efficiency – increased output Motor type mIM B3 mIM V1 J tolerance +3 dB(A) no-load Mech. speed limit IM B3 Terminal box Preferred SINAMICS converter – Base-load other SINAMICS converters current IL also possible LpfA, LWA, tolerance +3 dB(A) no-load kg kg kgm2 dB(A) dB(A) rpm Type Type A 1LP1312-3AB16-5... 1LP1312-3AB36-5... 1LP1312-3AB56-5... 1LP1312-3AB76-5... 1280 1470 1640 1800 1330 1520 1690 1850 3.3 4.2 4.8 5.7 85 85 85 85 100.5 100.5 100.5 100.5 3600 3600 3600 3600 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG37-4AA3 452 560 710 710 1LP1312-3BB56-1... 1LP1312-3BB76-1... 2260 2380 2310 2440 8.0 8.7 85 85 101 101 3300 3300 1XB7 740 1XB7 740 6SL3710-7LG38-1AA3 6SL3710-7LG38-8AA3 790 880 1LP1312-3AB16-6... 1LP1312-3AB36-6... 1LP1312-3AB56-6... 1LP1312-3AB76-6... 1LP1312-3BB56-6... 1LP1312-3BB76-6... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 6SL3710-7LG38-8AA3 6SL3710-7LG41-0AA3 400 560 710 790 880 1000 1LP1312-3AC16-7... 1LP1312-3AC36-7... 1LP1312-3AC56-7... 1LP1312-3AC76-7... 1LP1312-3BC56-7... 1LP1312-3BC76-7... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-7LG34-1AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 6SL3710-7LG38-1AA3 400 560 560 560 710 790 1LP1312-3AC16-8... 1LP1312-3AC36-8... 1LP1312-3AC56-8... 1LP1312-3AC76-8... 1LP1312-3BC56-8... 1LP1312-3BC76-8... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 730 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 6SL3710-7LG33-3AA3 6SL3710-7LG34-7AA3 6SL3710-7LG34-7AA3 6SL3710-7LG35-8AA3 6SL3710-7LG35-8AA3 6SL3710-7LG37-4AA3 320 452 452 560 560 710 1LP1322-3AB16-5... 1LP1322-3AB36-5... 1LP1322-3AB56-5... 1LP1322-3AB76-5... 1280 1470 1640 1800 1330 1520 1690 1850 3.3 4.2 4.8 5.7 85 85 85 85 100.5 100.5 100.5 100.5 3600 3600 3600 3600 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 560 710 710 710 1LP1322-3BB56-1... 1LP1322-3BB76-1... 2260 2380 2310 2440 8.0 8.7 85 85 101 101 3300 3300 1XB7 740 1XB7 740 6SL3710-2GF38-6AA3 6SL3710-2GF41-1AA3 836 1036 1LP1322-3AB16-6... 1LP1322-3AB36-6... 1LP1322-3AB56-6... 1LP1322-3AB76-6... 1LP1322-3BB56-6... 1LP1322-3BB76-6... 1280 1470 1640 1800 2260 2380 1330 1520 1690 1850 2310 2440 3.3 4.2 4.8 5.7 8.0 8.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 3000 3000 3000 3000 2600 2600 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GF34-7AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 6SL3710-1GF38-1AA3 6SL3710-2GF41-1AA3 6SL3710-2GF41-1AA3 452 710 710 790 1036 1036 1LP1322-3AC16-7... 1LP1322-3AC36-7... 1LP1322-3AC56-7... 1LP1322-3AC76-7... 1LP1322-3BC56-7... 1LP1322-3BC76-7... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 1XB7 740 6SL3710-1GF34-1AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 6SL3710-1GF38-1AA3 6SL3710-2GF41-1AA3 400 560 710 710 790 1036 1LP1322-3AC16-8... 1LP1322-3AC36-8... 1LP1322-3AC56-8... 1LP1322-3AC76-8... 1LP1322-3BC56-8... 1LP1322-3BC76-8... 1310 1490 1670 1780 2250 2400 1360 1540 1720 1830 2310 2450 5.7 7.0 8.1 8.9 14.3 15.7 85 85 85 85 85 85 100.5 100.5 100.5 100.5 101 101 2600 2600 2600 2600 2500 2500 1XB7 731 1XB7 731 1XB7 731 1XB7 731 1XB7 740 1XB7 740 6SL3710-1GF34-1AA3 6SL3710-1GF34-7AA3 6SL3710-1GF35-8AA3 6SL3710-1GF35-8AA3 6SL3710-1GF37-4AA3 6SL3710-1GF37-4AA3 400 452 560 560 710 710 Siemens D 81.8 · 04/2014 9 9/21 © Siemens AG 2014 Forced-air cooled motors — open version Dimensions 1LP1 motors Radially mounted equipment unit ■ Dimensional drawings IM B3 type of construction For terminal box dimensions, see Page 9/25 HC L HB' HK LL BE HD ØD F HB AC AG AD BC GA H HA EB DB BA E G_D081_XX_00424 C B BB ØK Ø K' AA A AB IM B35 and IM V1 types of construction For flange dimensions, see Page 9/24 (Z = the number of retaining holes), for terminal box dimensions, see Page 9/25 L HC LM HB' LL HK HH T HB ØP ØN ØD F HD AC ZxS E GA AD BE AG 9 M H HA EB DB G_D081_XX_00425 BA LA LE C ØK Ø K' B BB AA A AB Frame No. of size poles Motor type 315 1LP12..-3A.1.-.... 560 120 680 1155 630 180 780 180 315 28 1LP12..-3A.3.-.... ● 560 120 680 1155 630 180 780 200 315 28 28 35 1450 1670 85 M20 170 140 22 90 28 35 1470 1690 95 M24 170 140 25 100 1LP12..-3A.5.-.... 560 120 680 1155 835 180 985 180 315 28 1LP12..-3A.7.-.... ● 560 120 680 1155 835 180 985 200 315 28 28 35 1590 1810 85 M20 170 140 22 90 28 35 1610 1830 95 M24 170 140 25 100 1LP13.-3A.1.-…. 560 120 680 1245 630 180 780 180 315 28 1LP13.-3A.3.-…. ● 560 120 680 1245 630 180 780 200 315 28 28 35 1450 1765 85 M20 170 140 22 90 28 35 1470 1785 95 M24 170 140 25 100 1LP13.-3A.5.-…. 560 120 680 1245 835 180 985 180 315 28 1LP13.-3A.7.-…. ● 560 120 680 1245 835 180 985 200 315 28 28 35 1590 1905 85 M20 170 140 22 90 28 35 1610 1925 95 M24 170 140 25 100 1LP12.-3A.5.-…. 630 150 780 1305 800 220 980 200 355 35 1LP12.-3A.7.-…. ● 630 150 780 1305 800 220 980 224 355 35 35 42 1725 1975 95 M24 170 140 25 100 1LP13.-3A.5.-…. 630 150 780 1305 800 220 980 200 355 35 1LP13.-3A.7.-…. ● 630 150 780 1305 800 220 980 224 355 25 35 42 1725 2075 95 355 4, 6 4, 6 Dimension designation acc. to IEC A AA AB AC ● Bearing design for increased cantilever forces, for type of construction IM B3 only. 9/22 Siemens D 81.8 · 04/2014 B BA BB 1) C H HA K K' L 1) LM1) D DB E EB F GA 35 42 1790 2040 100 M24 210 180 28 106 M24 170 140 25 100 35 42 1790 2140 100 M24 210 180 28 106 With type of construction IM V1, dimensions L or LM may increase due to a protective cover for the fan motor. © Siemens AG 2014 Forced-air cooled motors — open version Dimensions 1LP1 motors Axially mounted equipment unit ■ Dimensional drawings IM B3 type of construction For terminal box dimensions, see Page 9/25 L LL BE HB' HK HC GA HD AC ØD F HB AG AD BC H HA EB DB BA E G_D081_XX_00418 C ØK B BB Ø K' AA A AB IM B35 and IM V1 types of construction For flange dimensions, see Page 9/24 (Z = the number of retaining holes), for terminal box dimensions, see Page 9/25 L LL HC HB' HK HH BE AD AG HB ZxS AQ AC ØP ØN ØD F E GA DB G_D081_XX_00419 BA C Frame No. of size poles Motor type 315 1LP12..-3A.1.-.... 1LP12..-3A.3.-.... 4, 6 4, 6 1LP12..-3A.5.-…. 1LP12..-3A.7.-…. ØK Ø K' B BB AA A AB Dimension designation acc. to IEC A 1LP12..-3A.5.-.... 1LP12..-3A.7.-.... 355 M H HA EB LA LE 9 LM HD T AA AB AC AQ B BA BB C H HA K K' L LM D 560 120 680 630 670 630 180 780 180 315 28 28 35 1525 1685 85 ● 560 120 680 630 670 630 180 780 200 315 28 28 35 1545 1705 95 560 120 680 630 670 835 180 985 180 315 28 28 35 1665 1825 85 DB E EB F GA M20 170 140 22 90 M24 170 140 25 100 M20 170 140 22 90 ● 560 120 680 630 670 835 180 985 200 315 28 28 35 1685 1845 95 M24 170 140 25 100 630 150 780 710 750 800 220 980 200 355 35 35 42 2115 2300 95 M24 170 140 25 100 ● 630 150 780 710 750 800 220 980 224 355 35 35 42 2180 2365 100 M24 210 180 28 106 ● Bearing design for increased cantilever forces, for type of construction IM B3 only. Siemens D 81.8 · 04/2014 9/23 © Siemens AG 2014 Forced-air cooled motors — open version Dimensions Flanges G_D081_XX_00026 ■ Dimensional drawings (Z = the number of retaining holes) Flange with through holes Motor type Frame size No. of poles Type of construction Flange type Dimension designation acc. to IEC LA 1LP1 315 355 4, 6 4, 6 9 9/24 Siemens D 81.8 · 04/2014 IM B35, IM V1 IM B35, IM V1 LE M N P S T Z 8 Flange 29 170 740 680 800 22 6 Flange (optional) 22 170 600 550 660 22 6 8 Flange 29 170 840 780 900 22 6 8 Flange (optional) 22 170 600 550 660 22 6 8 © Siemens AG 2014 Forced-air cooled motors — open version Dimensions Terminal boxes ■ Dimensional drawings LL BE HB' HK HC AG1 IM B3 type of construction HD HB AG AD BC G_D081_XX_00426 LL HC HB' HK HH AG1 IM B35 and IM V1 types of construction HD HB AG AD BE 9 G_D081_XX_00427 Motor type Frame size No. of poles Terminal box Dimension designation acc. to IEC AD AG AG1 BC BE HB HB' HH HC HD HK LL 1LP1 315 4, 6 1XB7 730 710 575 – 115 – 890 310 295 180 1025 255 345 1XB7 731 710 575 – 115 115 890 310 295 180 1025 255 345 1XB7 740 800 615 60 115 150 930 365 295 235 1110 340 425 GT640 655 555 – 115 110 870 225 295 155 970 170 310 1XB1 621 705 585 – 115 150 900 305 295 165 1020 250 330 1XB1 631 775 640 – 115 100 955 400 295 175 1090 320 555 1XB7 730 750 615 – 100 – 970 310 300 180 1105 255 345 1XB7 731 750 615 – 100 115 970 310 300 180 1105 255 345 1XB7 740 840 655 60 100 150 1010 365 300 235 1190 340 425 GT640 695 595 – 100 110 950 225 300 155 1050 170 310 1XB1 621 745 625 – 100 150 980 305 300 165 1100 250 330 1XB1 631 815 680 – 100 100 1035 400 300 175 1170 320 555 355 4, 6 Siemens D 81.8 · 04/2014 9/25 © Siemens AG 2014 Forced-air cooled motors — open version Dimensions Notes 9 9/26 Siemens D 81.8 · 04/2014 10 © Siemens AG 2014 Explosion-proof motors 10/2 10/2 10/2 10/2 10/3 10/3 10/4 10/4 10/4 10/4 10/4 10/4 10/5 10/7 10/7 10/7 Technical information Overview Classification of zones Types of protection Certification Overview of SIMOTICS FD 1MM, 1MH, 1MQ, 1MN explosion-proof motors Benefits Application Technical specifications General information Type of protection Ex nA for use in Zone 2 Type of protection Ex tc for use in Zone 22 Converter-fed (1MM1, 1MH1, 1MQ1, 1MN1) or mains-fed operation (1LH1) VIK version Coolant temperature Special technology Siemens D 81.8 · 04/2014 © Siemens AG 2014 Explosion-proof motors Technical information ■ Overview In many industrial and public sectors, explosion protection or explosion hazards are ever-present, e.g. in the chemicals industry, in refineries, on drilling platforms, at petrol stations, in feed manufacturing and in sewage treatment plants. The risk of explosion is always present when gases, fumes, mist or dust are mixed with oxygen in the air in an explosive ratio close to sources of ignition that are able to release the so-called minimum ignition energy. In the chemical and petrochemical industries in particular, when crude oil and natural gas are transported, or in mining, milling (e.g. grain and granular solids), this can result in serious injury to persons and damage to equipment. Classification of zones Areas subject to explosion hazard are divided into zones. Division into zones depends on the chronological and geographical probability of the presence of a hazardous, potentially explosive atmosphere. Information and specifications for classification of the zones are laid down in the following standards: • IEC/EN 60079-10-1 for gas atmospheres • IEC/EN 60079-10-2 for dust atmospheres Further, a distinction is made between various explosion groups as well as temperature classes and these are included in the hazard assessment. To ensure maximum safety in these areas, legislators in most countries have implemented appropriate stipulations in the form of laws and regulations based on national and international standards. Zone classification Gas atmosphere Zone classification Dust atmosphere Zone 22 Explosion-protected equipment is designed such that an explosion can be prevented when it is used properly. Zone 21 Safe Area The explosion-protected equipment can be designed in accordance with various types of protection. Zone 20 The local conditions must be subdivided into specified zones by the user with the assistance of the responsible authorities in accordance with the frequency of occurrence of an explosion hazard. Device (equipment) categories are assigned to these zones. The zones are then subdivided into possible types of protection and therefore into possible equipment (product) types. Zone 0 Zone 1 Safe Area Zone 2 G_D081_EN_00339 Depending on the particular zone and therefore the associated hazard, operating equipment must comply with defined minimum requirements regarding the type of protection. The different types of protection require corresponding measures to prevent ignition that should be implemented at the motor in order to prevent that a surrounding explosive atmosphere is ignited. 10 Zone Zone definition acc. to Gas1) Dust1) IEC/EN 60079-10-1 for gas atmospheres IEC/EN 60079-10-2 for dust atmospheres Assigned types of protection Category acc. to 94/9/EC 2 – An area in which in normal operation it is expected that an explosive gas atmosphere will occur only rarely and then only briefly. Ex nA 3G – 22 An area in which in normal operation it is expected that an explosive gas atmosphere in the form of a cloud of dust in air will occur only rarely and then only briefly. Ex tc2) 3D Types of protection Type of protection "Non-sparking" Ex nA acc. to IEC/EN 60079-15 Explosion-proof motors for converter-fed operation The type of protection Ex nA ensures that a motor in normal operation as well as when operated under deviating conditions as specified in the standard is not in a position to ignite a surrounding explosive gas atmosphere. This type of protection applies for electrical equipment protected using an enclosure and with limited surface temperature for use in areas in which combustible dust can occur in concentration levels that could cause a fire or an explosion. Principally, explosion-proof motors can be fed from converters. Particular attention must be paid to the interaction between the motor and converter system, especially with regard to the following aspects: • The harmonic content of the supply voltage raises the motor temperature, so the motor output must be reduced (see derating) • Less cooling of the motor at speeds below the rated speed • Voltage stress on the motor winding • Bearing currents 1) 2) Type of protection "Dust explosion protection" Ex tc acc. to IEC/EN 60079-31 Motors, which are certified for gas or dust protection, must not be used in hybrid mixtures! Hybrid mixtures: When explosive gas and dust atmospheres occur simultaneously. 10/2 Siemens D 81.8 · 04/2014 Motors are not approved for operation in environments containing conductive dust © Siemens AG 2014 Explosion-proof motors Technical information ■ Overview (continued) Certification IEC motors for use in hazardous zones are certified according to the IEC/EN 60079-0, IEC/EN 60079-15 or IEC/EN 60079-31 standards and EC Directive 94/9/EC (ATEX) and are marked according to the following schematic. Example "explosion-proof enclosure": CE 0158 II 2 G Ex de IIC T4 X CE marking Number of the certifying "notified" body (e.g. 0158 = EXAM) (not Zones 2, 22) Explosion protection marking (symbol) Device group: I = Underground II = All other areas Category Part 1 (zone): 1 (Zone 0/20), 2 (Zone 1/21), 3 (Zone 2/22) Category Part 2 (Ex atmosphere) G = Gas D = Dust Explosion protected equipment Type of protection (e.g. nA or tc) Explosion group and explosion subgroup II = Gas (IIA, IIB or IIC) III = Dust (IIIA, IIIB or IIIC) Temperature class or max. surface temperature T1 = 450 °C T2 = 300 °C T3 = 200 °C T1 = 25 °C Special conditions according to the operating instructions or EC type examination certificate Additional information on the subject of explosion protection, types of protection and zones is provided in the Siemens brochure "Explosion Protection". Overview of SIMOTICS FD 1MM, 1MH, 1MQ, 1MN explosion-proof motors SIMOTICS FD explosion-proof motors (1MM, 1MH, 1MQ, 1MN) correspond to the SIMOTICS FD non-explosion-proof motors (1LM, 1LH, 1LQ, 1LN). All technical specifications can be found in the selection and ordering data for the non-Ex motors 1LM, 1LH, 1LQ, 1LN (sections 4 to 7 of the catalog), whereby the rated output is subjected to derating in accordance with defined factors. For derating factors, see "Technical specifications" section "Derating". Sector Cate- Zone Frequency gory of occurrence of the Ex atmosphere Type of protection Gases and vapors (G) 3G Ex nA IIC T1 – T3 (non-sparking) Dust (D) 3D 2 22 rarely or briefly rarely or briefly Ex tc IIIB (non-conductive dust) To order explosion-proof motors, the letter "L" in position 2 of the Article No. for non-Ex motors must be replaced with the letter "M". The table below contains a complete overview of our explosionproof motors, their types of protection and their assignment to categories. It is important to note that depending on whether the motor is used for converter-fed operation or mains-fed operation, different order codes are required for unique selection of the required motor. TemperaDegree Motor type Operation Order ture class, of pro- (pos. 1-4 code max. tection of Article No.) surface temperature T125 °C IP55 IP55 1MM1 1MH1 1MQ1 1MN1 Mains (1MH1) 1MM1 1MH1 1MQ1 1MN1 Mains (1MH1) M72 Utilization according to thermal class Standard 130 (B) 155 (B) IEC/EN 60079-0 IEC/EN 60079-15 Converter M73 M35 130 (B) 155 (F) IEC/EN 60079-0 IEC/EN 60079-31 Converter M39 Siemens D 81.8 · 04/2014 10/3 10 © Siemens AG 2014 Explosion-proof motors Technical information ■ Benefits The explosion-proof motors from Siemens offer the user numerous advantages: • The motors are designed to IEC/EN 60079-0 and IEC/EN 60079-15 or IEC/EN 60079-31 and EC Directive 94/9/EC (ATEX). As product supplier, Siemens accepts responsibility for compliance with the applicable product standards for the selected equipment. • By using this product, the plant operating company satisfies Directive 1999/92/EC in accordance with Appendix II B. The plant operating company is responsible for correct selection and proper use of the equipment. • Comprehensive series of Ex motors for protection against gas and dust. • Individual versions of motors are possible thanks to the numerous catalog order codes. • Further special versions are possible on request. • The Operating Instructions (Compact) are available in all the official EU languages as well as Russian and Chinese. ■ Application The explosion-proof motors are used in the following sectors to prevent explosion hazards that result in serious injury to persons and severe damage to equipment. • Chemical and petrochemical industry • Production of mineral oil and gas • Gas works • Gas supply companies • • • • • • Petrol stations Coking plants Mills (e.g. grain, solids) Sewage treatment plants Wood processing (e.g. sawdust, tree resin) Other industries subject to explosion hazards ■ Technical specifications General information Ex motors in vertical type of construction with shaft extension pointing down must have a protective cover (position 14 of Article No.: G). Extensive Operating Instructions (Compact) are supplied as standard with explosion-proof motors in English and German. Translations are also available in all the other official EU languages as well as in Russian and Chinese. For all explosion-proof motors, designs according to UL (order code D31) and CSA (order code D40) are not possible. 10 Motor connection For 1MM1, 1MH1, 1MQ1 and 1MN1 motors in the explosionproof design, the cable entry plate is supplied undrilled as standard. This enables you to adapt the number and size of the boreholes to the rated conditions. The cable entry can be rotated by 180°. The certificates for the motors for hazardous areas are stored with the documentation in the selection tool DT Configurator. Certified motor protection switches/tripping units must always be used for motor protection, see Catalog IC 10. When metal armored cables are routed into the auxiliary terminal boxes, the metal shield must only be grounded once: either in the auxiliary terminal box or in the control room of the operator. In the case of SIMOTICS FD motors 1MM1, 1MH1, 1MQ1 and 1MN1, monitoring of the bearing temperature is only mandatory for Zone 22 (order code A72). Type of protection Ex nA for use in Zone 2 • Design for Zone 2 for mains-fed operation (order code M72) • Design for Zone 2 for converter-fed operation (order code M73) 1MM1, 1MH1, 1MQ1 and 1MN1 motors are modified for this purpose in the "Non-sparking" design and are suitable for use in hazardous areas of Zone 2 for temperature classes T1 to T3. The maximum surface temperature that can occur during operation is below the limit temperature of the respective temperature 10/4 Siemens D 81.8 · 04/2014 class. The ventilation system complies with IEC/EN 60079-0/ -15/-31. The motors are equipped with an external grounding terminal. The terminal box is designed for Ex e type of protection. Ambient temperature -0 °C to +60 °C, whereby derating applies from 40 °C upwards. Other temperatures are available on request. The rating plate or the extra rating plate contains the text: II 3G Ex nA IIC T3 Type of protection Ex tc for use in Zone 22 Ex tc in accordance with IEC/EN 60079-31 for Zone 22 with non-conductive dust (IP55) • Design for Zone 22 for mains-fed operation (order code M35) • Design for Zone 22 for converter-fed operation (order code M39) 1MM1, 1MH1, 1MQ1 and 1MN1 motors are modified for this purpose for use in zones subject to dust and explosion hazards. The surface temperature is ≤ 125 °C at rated duty. An external grounding terminal and a metal external fan are fitted to the motors. Certification: • Zone 22: EC Declaration of Conformity, IEC Ex Certificate of Conformity Identification on the rating plate (extra rating plate for SIMOTICS FD motors): • Zone 22: II 3D Ex tc IIIB T125 °C Ambient temperature -0 °C to +60 °C, whereby derating applies from 40 °C upwards. Other temperatures are available on request. This version can be ordered with the note "Operation in Zone 2 or Zone 22". © Siemens AG 2014 Explosion-proof motors Technical information ■ Technical specifications (continued) Converter-fed (1MM1, 1MH1, 1MQ1, 1MN1) or mains-fed operation (1LH1) With converter-fed operation, the torque reduction factors for drives for fans, pumps and compressors must be configured according to the table in the section "Derating". The torque reduction factors for constant torque drives will be configured, on request, on specification of the speed control range and the required torque. For converter-fed operation, Ex motors must always be monitored using PTC thermistors. Certified tripping units are required for this purpose, see Catalog IC 10. Explosion-proof motors 1MM1, 1MH1, 1MQ1 and 1MN1 The motors of the 1MM1, 1MH1, 1MQ1 and 1MN1 series are available in Ex nA (Zone 2) or Ex tc (Zone 22) types of protection. The motors have PTC thermistors for alarm and tripping in accordance with thermal class 155 (F). Ambient temperatures in the range from -20 to +60 °C are possible, whereby additional derating applies from +40 °C upwards. Please inquire in such cases. For 1MM1 motors, order code K35 (metal external fan) must be specified in the order. The 1MM1...-3BB..-1… motors are an exceptional case, however, because they are equipped with a unidirectional external fan. When ordering these motors, order code K37 must be specified for clockwise rotation or order code K38 for anticlockwise rotation. An EC Declaration of Conformity is enclosed with every motor. In the case of motors for converter-fed operation, the following information must be supplied in the order or inquiry in plain text: • For a constant torque drive (order code B61: T = const) or drives for fans, pumps and compressors (order code B60: M ~ n2) *) • Maximum load torque • Speed control range • Utilized thermal class that the motor should or must comply with Note: Motors of the 1L.1 series (non-Ex motors) are utilized in accordance with thermal class 180 (H)/155 (F) (or 155 (H)/130 (B) – order code C10). Derating of motors of the 1M.1 series (Ex motors) results in a corresponding reduction in thermal utilization. These specifications regarding operation are labelled on an extra rating plate on the motor. The rating data on the rating plate is specified for the load torque at maximum speed. Type of protection Ex nA for use in Zone 2 The motors are modified for operation in Zone 2 and designed for compliance with temperature class T3 (maximum surface temperature of 200 °C inside the motor). • Design for Zone 2 for mains-fed operation – order code M72: Standard utilization in accordance with thermal class 130 (B). Utilization in accordance with thermal class 155 (F) with service factor (order code C14) possible on request. • Design for Zone 2 for converter-fed operation – order code M73: Standard utilization in accordance with thermal class 155 (F) in drives for fans, pumps and compressors (order code B60: M ~ n2) *). For utilization in accordance with thermal class 130 (B) the output must be reduced by 14 % from the rated output of a comparable 1L.1 (non-Ex) motor. In constant torque *) drives (order code B61: T = const) the thermal utilization depends on the value of the load torque and the speed control range ( 130 (B) and/or 155 (F)). The maximum possible constant torque is dependent on the speed control range and the cooling method of the motor thermal torque limit characteristic. IEC/EN 60079-15 specifies that the motor and converter must be tested as a unit. As an alternative, however, it is also admissible for the thermal response to be determined by a calculation. The thermal response of the motors for operation on Siemens converters is known, so a system test is not generally required for drives for fans, pumps and compressors. Please inquire as to whether a system test is necessary or not in the case of a constant torque drive constant torque drives on request only. The following identification is included on an extra rating plate on the motor: II 3G Ex nA IIC T3 Gc, IEC/EN 60079 Type of protection Ex tc for use in Zone 22 for non-conductive dust The motors are modified for operation in Zone 22 and designed such that an external motor surface temperature of 125 °C is not exceeded. For the 1MM1, 1MH1, 1MQ1 and 1MN1 motor series, monitoring of the bearing temperature is required for operation in Zone 22. These motors are therefore equipped with bearing temperature sensors as standard. • Design for Zone 22 for mains-fed operation – order code M35: Standard utilization in accordance with thermal class 130 (B). Utilization in accordance with thermal class 155 (F) with service factor (order code C14) possible on request. • Design for Zone 22 for converter-fed operation – order code M39: Standard utilization approximately in accordance with thermal class 155 (F) in drives for fans, pumps and compressors (order code B60: M ~ n2) *). For utilization in accordance with thermal class 130 (B) the output must be reduced by 14 % from the rated output of a comparable 1L.1 (non-Ex) motor. In constant torque drives (order code B61: T = const) the thermal utilization depends on the value of the load torque and the speed control range ( 130 (B) and/or 155 (F)). The maximum possible constant torque is dependent on the speed control range and the cooling method of the motor thermal torque limit characteristic. When configuring these motors, therefore, it is important to note that the maximum admissible torque, as a function of speed, is not exceeded. Please inquire as to whether a system test is necessary or not in the case of a constant torque drive constant torque drives on request only. The following identification is included on an extra rating plate on the motor: II 3D Ex tc IIIB T125 °C Dc, IEC/EN 60079 Operation on non-Siemens converter It is normally necessary to inquire regarding operation of the motors on a non-Siemens converter, regardless of the type of protection and torque characteristic of the driven machine. A test must be performed to ensure that the temperature limits are complied with. This should take place at the customer's premises (not possible in the factory). M = Torque Siemens D 81.8 · 04/2014 10/5 10 © Siemens AG 2014 Explosion-proof motors Technical information ■ Technical specifications (continued) Derating In comparison to non-Ex motors, the rated output of Ex motors is reduced. Derating is performed in accordance with defined factors. The reference output here is the rated output of the non-Ex motor. Derating factors for motors of the 1M.1 series Motor type Zone (order code) Zone 2 (M72) Zone 2 (M73) Zone 22 (M35) Zone 22 (M39) Torque (order code) *) M ~ n2 (B60) M ~ n2 (B60) T = const (B61) M ~ n2 (B60) M ~ n2 (B60) T = const (B61) 1MM1 – 0.9 O. R. – 0.8 O. R. 1MQ1 – 0.9 O. R. – 0.8 O. R. 1MH1 1 0.9 O. R. 1 0.9 O. R. 1MN1 – 0.9 O. R. – 1 O. R. Rating plate labeling for Ex motors of the SIMOTICS FD series Rating plate In contrast to the non-Ex motor, the rating plate specifies that the voltage tolerance is compliant with IEC/EN 60034-1, Zone A. 3~ Mot. 1MM1222-3AB71-2AA0-Z m: 1.8 t IP 55 nmax: 3000 1/min U [V] I [A] 380 D *) 580 SIMOTICS FD IM B3 Ta: -20…+40°C If, in addition to order code M72 or M73, order code D36 (conformity statement) and/or D37 (IEC Ex certificate) is also specified in the order, the corresponding certificate numbers will be stamped on the rating plate (only applicable to order codes M72 and M73). NoN- 9900006060001 / 2014 Th.Cl.: 180(H) Util.:155(F) IEC/EN 60034-1 P [kW] cosφ n [1/min] f [Hz] 320 0.87 1500 50.30 *) Valid for: Order code M72: Zone 2 for mains-fed motors Order code M73: Zone 2 for converter-fed motors Order code M35: Zone 22 for mains-fed motors Order code M39: Zone 22 for converter-fed motors Eff. 96.2% Mot. design: FOR INVERTER DUTY ONLY Line supply: 400V/50Hz 10 DEW0400 Made in Germany D-90441 Nürnberg G_D081_XX_00471 *) VARIATIONS ACC. TO IEC/EN 60034-1, ZONE A Extra rating plate On the extra rating plate, the torque characteristic, speed or frequency control range and the torque are specified as a minimum. If, in addition to order code M72 or M73, order code D36 (conformity statement) and/or D37 (IEC Ex certificate) is also specified in the order, the corresponding certificate numbers will be stamped on the rating plate (only applicable to order codes M72 and M73). torque characteristic: M~n2 Z0400 speed range: 150...1500 rpm max. torque: 2037 Nm G_D081_XX_00472 *) M = Torque 10/6 Siemens D 81.8 · 04/2014 Valid for: Order code M73: Zone 2 for converter-fed motors Order code M39: Zone 22 for converter-fed motors Order code B60: M ~ n2 *) © Siemens AG 2014 Explosion-proof motors Technical information ■ Technical specifications (continued) Ex plate Special technology Zone 2: "Special technology" comprises mounted technology that is compatible with explosion-proof motors. Explosion-proof motors can be implemented in a broader range of applications when explosion-proof rotary pulse encoders or explosion-proof separately driven fans are mounted. I I 3G Z9955 Ex nAe ll T3 Gc IEC / EN 60079 D21377367010001 G_D081_XX_00470 Note: The letter(s) between "Ex nA" and "II T3 Gc" vary according to the additional components of the motor (e.g. temperature sensor, anti-condensation heating, etc.). Valid for: Order code M72: Zone 2 for mains-fed motors Order code M73: Zone 2 for converter-fed motors Zone 22: Z9955 DD1406366010001 For motors of the 1MQ1 series with forced ventilation, only radially mounted separately driven fans are available (position 16 of Article No. = 2, 3, 4). Explosion-proof rotary pulse encoder The rotary pulse encoder can only be mounted on a standard non-drive end (NDE), i.e. a second shaft extension or protective cover cannot be supplied. In the case of a vertical mounting position for motors of the 1MM1 series, therefore, a suitable cover must be implemented by the customer to prevent small parts from falling into the fan cover (see also standard IEC/EN 60079-0). The type of protection of the rotary pulse encoder must be observed. The relevant data are stamped on the rating plate of the rotary pulse encoder. I I 3D Ex tc IIIB T125°C Dc IEC / EN 60079 The use of a separately driven fan is recommended to increase motor utilization at low speeds and to limit noise generation at speeds significantly higher than the synchronous speed. G_D081_XX_00469 Valid for: Order code M35: Zone 22 for mains-fed motors Order code M39: Zone 22 for converter-fed motors VIK version • VIK standard version – Order code K30 "VIK" identification on rating plate. • VIK Ex n version – Order codes K30 + C27 "VIK" and "Ex nA IIC T3" identification on the rating plate according to Directive 94/9/EC (ATEX) "Ex nA IIC T3" identification will only be included on the rating plate on request as recommended by VIK. Note: Order code C27 can only be ordered in combination with order code K30. Both versions include technology for Zone 2 to type of protection Ex nA IIC T3. Motors up to frame size 355 can be supplied in accordance with the technical requirements of the VIK ("Verband der Industriellen Energie- und Kraftwirtschaft e. V.", the Association of the Industrial Energy and Power Industry). Coolant temperature Coolant temperature –40 to +40 °C for explosion-proof motor For all 1MM1, 1MH1, 1MQ1 and 1MN1 motors in explosion protection types Ex nA or Ex tc (Zone 2/22), the operating ambient temperature range can be optionally increased to – 40 °C. Extensive technical measures are necessary in this case (e.g.: metal external fan). Order code D19 When an explosion-proof rotary pulse encoder is mounted, the length of the motor increases by dimension l. For an explanation of the additional dimensions and weights, see "Dimensions and weights of explosion-proof rotary pulse encoders" on the website of the encoder manufacturer. HOG 10 and HOG 11 rotary pulse encoders The HOG 10 and HOG 11 rotary pulse encoders have an extremely rugged design and are therefore ideally suited to difficult operating conditions. The following order codes are available for explosion-proof rotary pulse encoders (ATEX): • H73: HOG 10 D 1024 I • H83: HOG 10 DN 2048 • H88: HOG 11 DN 1024 I (16 mm) special corrosion protection Encoder mounting for use below –20 °C and above +40 °C is available on request. Please consult the manufacturer's website for further information and technical specifications of the encoders. Manufacturers of rotary pulse encoders Types: HOG 10, HOG11: Baumer Hübner GmbH Max-Dohrn-Str. 2+4 10589 Berlin Germany Tel. +49 (0)30-6 90 03-0 Fax +49 (0)30-6 90 03-1 04 www.baumerhuebner.com E-mail: [email protected] Siemens D 81.8 · 04/2014 10/7 10 © Siemens AG 2014 Explosion-proof motors Technical information Notes 10 10/8 Siemens D 81.8 · 04/2014 11 © Siemens AG 2014 Article No. supplements and special versions 11/2 11/3 11/4 11/5 11/6 11/7 11/7 11/20 Voltages Types of construction Terminal box position Separately driven fan position/ Heat exchanger position Mechanical limit speed Options • Motors without explosion protection • Explosion-proof motors Siemens D 81.8 · 04/2014 © Siemens AG 2014 Article No. supplements and special versions Voltages ■ Selection and ordering data Special versions Voltage code 12th position of the Article No. System Catalog section description 4 5 6th position of the Article No. Air-cooled, enclosed version with selfventilation 1LM1 6 7 8 Water-cooled version with forced-air cooling 1LQ1 with waterjacket cooling 1LH1 9 Air-cooled, open version with heat exchanger 1LN1 with selfventilation 1LL1 with forced-air cooling 1LP1 400 V 1 Mains-fed operation Converter-fed operation with IICC C 500 insulation system 500 V 2 Converter-fed operation with IICC C 500 insulation system Converter-fed operation with IICC C 690 insulation system 0 – 1, 2, 4, 6 3 1, 3 4, 6 2 4, 6 – – – – – 690 V without output filter 3 Converter-fed operation with IICC C 690 insulation system 1, 2, 4, 6 3 690 V with output filter 4 Mains-fed operation 0 Converter-fed operation with IICC C 500 insulation system 4, 6, 8 1, 2, 4, 6 3 – – – – – – – – – – Voltage at 60 Hz and 60 Hz output required 11 460 V; 60 Hz output 575 V; 60 Hz output 5 Mains-fed operation 0 11/2 – – – – – Converter-fed operation with IICC C 500 insulation system 1, 2, 4, 6 3 6 Converter-fed operation with IICC C 690 insulation system 1, 2, 4, 6 3 Without additional charge Not possible – 4, 6, 8 Siemens D 81.8 · 04/2014 455 355 – Voltage at 50 Hz and 50 Hz output 400 315 – 455 – 400 355 – 315 – 455 355 400 315 455 400 355 315 – 455 – 400 355 – 315 – 455 355 4, 6, 8 400 No. of poles 315 1L.1 . . . - . . . . ■ - . . . . 1L.1 . . . ■ - . . . . . - . . . . Frame size © Siemens AG 2014 Article No. supplements and special versions Types of construction ■ Selection and ordering data Types of construction Type of Catalog section construction 4 5 code 14th position of Air-cooled, enclosed the version Article No. with selfwith forced-air ventilation cooling 1LM1 6 7 8 Water-cooled version 9 Air-cooled, open version with waterjacket cooling with heat exchanger with selfventilation with forced-air cooling 1LH1 1LN1 1LL1 1LP1 1LQ1 IM V5 C O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. IM V6 D O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. IM V15 E O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. IM B5 with support foot F O. O. R. R. O. O. R. R. O. O. R. R. – – O. O. R. R. O. O. R. R. IM V1 with protective cover G ✓ ✓ ✓ ✓ – – – – ✓ ✓ ✓ ✓ IM V1 without protective cover J ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ – – – – IM B35 K ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 455 355 A 400 315 455 355 400 315 455 355 400 315 455 355 400 315 455 355 400 315 455 355 IM B3 1L.1. . . - . . . . . - . ■ . . 400 315 Frame size Without flange With flange 11 Standard version ✓ With additional charge – Not possible O. R. On request Siemens D 81.8 · 04/2014 11/3 © Siemens AG 2014 Article No. supplements and special versions Terminal box position ■ Selection and ordering data Terminal box position Terminal Catalog section box position 4 5 code 15th position Air-cooled, enclosed of the version Article No. with selfwith forced-air ventilation cooling 1LM1 6 7 8 Water-cooled version 9 Air-cooled, open version with waterjacket cooling with heat exchanger with selfventilation with forced-air cooling 1LH1 1LN1 1LL1 1LP1 1LQ1 Standard version (terminal box on DE top) A – – Version with one terminal box Terminal box on DE right-hand B ✓ ✓ – – – – Terminal box on DE left-hand C ✓ ✓ – – – – Terminal box on NDE top D ✓ ✓ ✓ ✓ ✓ ✓ – – ✓ ✓ ✓ ✓ 1) 1) 1) 1) ✓ ✓ 1) 1) ✓ ✓ 1) 1) Terminal box on NDE right-hand E Terminal box on NDE left-hand F ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ – – – – ✓ ✓ ✓ ✓ – – – – Version with two terminal boxes 11 Terminal boxes both top (NDE and DE) K O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Terminal boxes both left-hand (NDE and DE) L O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Terminal boxes both right-hand (NDE and DE) M O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Terminal boxes both on DE (right-hand and left-hand) N O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Terminal boxes both on NDE (right-hand and left-hand) O O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Standard version Without additional charge ✓ With additional charge – Not possible O. R. On request 1) Possible terminal box positions dependent on separately driven fan position. 11/4 Siemens D 81.8 · 04/2014 455 355 Terminal box position 400 315 455 355 400 315 455 355 400 315 455 355 400 315 455 355 400 315 455 400 355 1L.1. . . - . . . . . - . . ■ . 315 Frame size © Siemens AG 2014 Article No. supplements and special versions Separately driven fan position/Heat exchanger position ■ Selection and ordering data Separately driven fan position/Heat exchanger position Separately Catalog section driven fan/heat 4 5 exchanger position code Air-cooled, enclosed 16th position version of the with selfwith forced-air Article No. ventilation cooling with waterjacket cooling with heat exchanger with selfventilation with forced-air cooling 1LM1 1LH1 1LN1 1LL1 1LP1 6 7 8 Water-cooled version 1LQ1 9 Air-cooled, open version – – – – – – 455 355 400 315 455 355 400 315 455 355 400 315 455 355 400 315 455 355 400 315 455 400 355 1L.1. . . - . . . . . - . . . ■ 315 Frame size Separately driven fan position/Heat exchanger position No separately driven fan, no heat exchanger 0 Separately driven fan for air-cooled motors Separately driven fan unit 1 NDE, axial – – – – – – – – – – – – Separately driven fan unit 2 NDE, top – – – – – – – – Separately driven fan unit 3 NDE, right-hand – – – – – – – – Separately driven fan unit 4 NDE, left-hand – – – – – – – – – – – – – – ✓ ✓ – – – – Heat exchanger for modular motors Heat exchanger, top ✓ – 5 Standard version Without additional charge With additional charge Not possible 11 Siemens D 81.8 · 04/2014 11/5 © Siemens AG 2014 Article No. supplements and special versions Mechanical limit speed ■ Selection and ordering data Mechanical limit speed for non-standard type of construction or bearings Motor type Type of construction 1..1...-3AB..-.... 1..1...-3AC..-.... 1..1...-3BB..-.... 1..1...-3BC..-.... with order code – K20 M61 – K20 M61 – K20 M61 – K20 M61 IM B3 3000 2600 – 2600 2600 – 2600 2400 – 2200 2200 – IM B35 3000 – 3000 2600 – 2600 2600 – 2400 2200 – 2400 IM V1 2500 – 1500 2500 – 1500 2000 – 1000 2000 – 1000 IM V15, V5, V6 O. R. O. R. The mechanical limit speed for IM B3 type of construction is entered in the selection and ordering data in accordance with the cooling method. For types of construction other than IM B3, or order codes such as K20 or M61, the mechanical limit speed reduces in accordance with the table. 11 11/6 Siemens D 81.8 · 04/2014 O. R. O. R. © Siemens AG 2014 Article No. supplements and special versions Options Motors without explosion protection ■ Selection and ordering data Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 8 Water-cooled version 9 Air-cooled, open version with selfventilation with forcedair cooling with waterjacket cooling with heat exchanger with selfventilation with forcedair cooling 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 – – – 6 PTC thermistors for alarm and A12 tripping, without lightning arresters 6) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 2 temperature sensors KTY 84-130 A25 6 temperature sensors KTY 84-130 A27 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 6 Pt100 resistance thermometers 6) A61 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 6 Pt100 resistance thermometers, 3-wire circuit from auxiliary terminal box (option M50 or M88) 6) A64 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ A72 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 2 Pt100 screw-in resistance therA78 mometers in basic circuit for rollingcontact bearings, 3-wire circuit from auxiliary terminal box ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 2 Pt100 double screw-in resistance thermometers in 3-wire circuit for rolling-contact bearings ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ – – – 455 355 – 400 315 – 455 355 – 400 315 – 455 355 – 400 315 – 455 355 – 400 315 455 355 400 315 455 400 355 ✓ ✓ 1L .1. . . - . . . . . - . . . . -Z 315 Frame size Preferred motors Standardline 35) B20 Motor protection – winding monitoring Motor protection – bearing monitoring 2 Pt100 screw-in resistance thermometers in basic circuit for rollingcontact bearings A80 Motor protection – other monitoring functions Leakage water detection H08 – – ✓ ✓ – CMS2000 condition monitoring systems 29) 30) M49 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Subsequently rotatable main terminal box 9) J12 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Two-part plate on terminal box 1) 10) K06 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Larger terminal box 1XB1 631 1) 9) 31) L00 – – – ✓ ✓ – – – Undrilled entry plate L01 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Larger terminal box 1XB1 621 1) 9) M58 – – – ✓ ✓ – – – Larger terminal box 1XB7 731 M70 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Larger terminal box 1XB7 740 9) M71 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ PE connection without cable lug Q00 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ – – – – Motor connection – terminal box – – – – – – 11 – – For legends and footnotes, see Page 11/32. Siemens D 81.8 · 04/2014 11/7 © Siemens AG 2014 Article No. supplements and special versions Options Motors without explosion protection Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 8 Water-cooled version 9 Air-cooled, open version with selfventilation with forcedair cooling with waterjacket cooling with heat exchanger with selfventilation with forcedair cooling 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 Motor connection – terminal box – cable entry Cable entry from right-hand 9) L51 Cable entry from left-hand 9) L52 9) L61 Cable entry from NDE 9) L62 Cable entry from the bottom 9) L63 Cable entry from the top 9) N83 Cable entry from DE Motor connection – auxiliary terminal box DIN 89280 cable gland, maximum configuration 8) K57 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 6 cables protruding, 1.5 m long 1) L48 – – – – O. O. R. R. – – – – – – 6 cables protruding, 3 m long 1) L49 – – – – O. O. R. R. – – – – – – Auxiliary terminal box 1XB3020 L97 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Auxiliary terminal box 1XB9016 (cast-iron) 29) 30) M50 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Auxiliary terminal box 1XB9015 (stainless steel) 29) 30) M51 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Auxiliary terminal box 1XB9014 (aluminum) 29) 30) M88 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Anti-condensation heating for 230 V K45 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ – – – – Anti-condensation heating for 115 V K46 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ – – – – Anti-condensation heating for 400 V L08 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ – – – – Anti-condensation heating for 500 V 2) L09 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ – – – – Anti-condensation heating Winding modification 11 Standard winding; non-standard voltage 3) M1Y O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Non-standard winding 3) M2Y – – – – – – Non-standard rated speed 32) N1Y O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Design with 2 galvanically separated C21 windings for operation with converter O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. – – – – – – 2) Ventilation Filter for self-ventilation G13 ✓ ✓ – – – – – – ✓ ✓ – Filter for forced ventilation 16) G12 – ✓ ✓ – – – – – ✓ ✓ Metal external fan K35 ✓ ✓ – – – – – ✓ ✓ – Separately driven fan with non-standard voltage 3) 16) Y81 – O. O. R. R. – – O. O. R. R. – O. O. R. R. For legends and footnotes, see Page 11/32. 11/8 Siemens D 81.8 · 04/2014 – – – – – – – 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 1L .1. . . - . . . . . - . . . . -Z 315 Frame size © Siemens AG 2014 Article No. supplements and special versions Options Motors without explosion protection Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 8 Water-cooled version 9 Air-cooled, open version with selfventilation with forcedair cooling with waterjacket cooling with heat exchanger with selfventilation with forcedair cooling 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 1L .1. . . - . . . . . - . . . . -Z 315 Frame size Bearings and lubrication Measuring nipple for SPM shock pulse measurement for bearing inspection 15) G50 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Shock pulse measurement, fixed sensor and distributor box H05 O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Shock pulse measurement, complete alarm box H07 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Prepared for mounting of a vibration sensor SIPLUS CMS2000 VIB-SENSOR S01 15) H69 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Bearing design for increased cantilever forces 18) 20) K20 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Spent grease removal K41 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Automatic re-lubricating device EasyMatic 12) N30 O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Automatic re-lubricating device STAR Control TIME M120 12) N31 O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Automatic re-lubricating device STAR Control Impuls L250 12) N32 O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Vibration quantity level B 5) 21) 22) K02 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Full-key balancing L68 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ K16 ✓ ✓ – – ✓ ✓ – – ✓ ✓ – Shaft extension with standard dimensions, without feather keyway K42 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Non-standard cylindrical shaft extension Y55 • and identification code ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Anti-clockwise direction, unidirectional fan 42) K98 – ✓ – – – – – – – ✓ – – Both directions of rotation 42) K99 – O. R. – – – – – – – O. R. – – IP65 degree of protection 20) K50 O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. – – – – IP56 degree of protection (non-heavy-sea) 16) 20) K52 ✓ ✓ – ✓ ✓ ✓ ✓ – – – – Pipe connection without socket on NDE from right-hand 27) K77 – – O. O. R. R. – – – – – – O. O. R. R. Pipe connection without socket on NDE from left-hand 27) K78 – – O. O. R. R. – – – – – – O. O. R. R. Pipe connection without socket on NDE from top 27) K79 – – O. O. R. R. – – – – – – O. O. R. R. Balance and vibration quantity Shaft Second standard shaft extension – 14) 39) 40) 11 Direction of rotation Degrees of protection – Pipe connection For legends and footnotes, see Page 11/32. Siemens D 81.8 · 04/2014 11/9 © Siemens AG 2014 Article No. supplements and special versions Options Motors without explosion protection Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 8 Water-cooled version 9 Air-cooled, open version with selfventilation with forcedair cooling with waterjacket cooling with heat exchanger with selfventilation with forcedair cooling 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 – – – ✓ ✓ – – – – – – Water connection from top K61 – – – – ✓ ✓ – – – – – – Water connection from right-hand (view from DE) K62 – – – – ✓ ✓ – – – – – – Water connection from left-hand (view from DE) K63 – – – – ✓ ✓ – – – – – – Mounting a coupling provided 5) 19) L17 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Motor mounting material for mounting on steel foundation 25) L31 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Rust-resistant screws (externally) 28) M27 O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Flange version A660 instead of standard version 24) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Mechanical options M61 Colors and paint finish Standard finish in RAL 7030 stone gray 11 Unpainted (only cast-iron parts primed) K23 Special finish in RAL 7030 stone gray K26 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Standard finish in other colors Y53 • and standard finish in RAL …. ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Special finish in other colors Y54 • and special finish in RAL …. ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Second rating plate, loose K31 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extra rating plate with identification codes Y82 • and identification code ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Temperature class 180 (H), used acc. to 155 (F) 1) C14 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Temperature class 180 (H), used acc. to 130 (B) 2) C10 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Rating plate and extra rating plates Utilization Coolant temperature and site altitude Coolant temperature –50 to +40 °C D02 O. O. R. R. O. O. R. R. – – – – – – – – Coolant temperature –40 to +40 °C D03 O. O. R. R. O. O. R. R. – – – – – – – – Coolant temperature –30 to +40 °C D04 ✓ ✓ ✓ ✓ – – – – – – – – Site altitude up to 2000 m above sea level D07 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Site altitude up to 3000 m above sea level D09 O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. For legends and footnotes, see Page 11/32. 11/10 Siemens D 81.8 · 04/2014 455 355 – Water connection and material 400 315 455 355 400 315 455 355 400 315 455 400 355 315 455 355 400 315 455 355 Cooling water pipes in stainless steel M85 instead of copper 1L .1. . . - . . . . . - . . . . -Z 400 315 Frame size © Siemens AG 2014 Article No. supplements and special versions Options Motors without explosion protection Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 8 Water-cooled version 9 Air-cooled, open version with selfventilation with forcedair cooling with waterjacket cooling with heat exchanger with selfventilation with forcedair cooling 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 – – – – D12 – – – – Coolant temperature 55 °C D13 – – – – Coolant temperature 60 °C D14 O. O. R. R. O. O. R. R. – – – – O. O. R. R. O. O. R. R. Cooling water temperature 30 °C D15 – – – – ✓ ✓ ✓ ✓ – – – – Cooling water temperature 35 °C D16 – – – – ✓ ✓ ✓ ✓ – – – – Cooling water temperature 40 °C D17 – – – – ✓ ✓ ✓ ✓ – – – – Increased air humidity/temperature with 30 to 60 g water per m3 of air C19 – – – – O. O. R. R. O. O. R. R. – – – – Increased air humidity/temperature with 60 to 100 g water per m3 of air C26 – – – – O. O. R. R. O. O. R. R. – – – – Outdoor use with high salinity or areas with almost continuous condensation (corrosivity grade C5-M/ C5-I) E81 – – – – O. O. R. R. O. O. R. R. – – – – Outdoor use with moderate salinity (corrosivity grade C4) E82 – – – – O. O. R. R. O. O. R. R. – – – – Outdoor use with low salinity (corrosivity grade C3) E83 – – – – O. O. R. R. O. O. R. R. – – – – 455 D11 Coolant temperature 50 °C 400 355 315 455 400 355 315 455 355 400 315 455 355 400 315 455 400 355 315 455 400 355 Coolant temperature 45 °C 1L .1. . . - . . . . . - . . . . -Z 315 Frame size Coolant temperature and site altitude (continued) Special ambient conditions Design in accordance with standards and specifications Electrical according to NEMA MG1-12 D30 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Design according to UL with "Recognition Mark" D31 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Canadian regulations (CSA) D40 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ VIK version K30 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ – – Mounting of LL 861 900 222 with Advanced Diagnostic System 2) 38) H16 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Mounting of LL 861 900 220 2) 38) – – 11 Special technology – encoders H70 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 2) 38) H73 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Mounting of HOG 10 DN 2048 2) 38) H83 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Mounting of HOG 11 DN 2048 2) 38) H84 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Mounting of HOG 11 DN 1024 I (16 mm) with special anti-corrosion protection 2) 38) H88 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Mounting of HOG 10 DN 1024 I with N06 terminal box/protection against dust (zero signal) 2) 38) O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Mounting of HOG 10 D 1024 I with terminal box/protection against humidity 2) 38) N07 O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Mounting of HOG 10 DN 1024 I with N08 terminal box/protection against humidity (zero signal) 2) 38) O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Mounting of HOG 10 D 1024 I Mounting of HOG 10 D 1024 I with N05 terminal box/protection against dust 2) 38) For legends and footnotes, see Page 11/32. Siemens D 81.8 · 04/2014 11/11 © Siemens AG 2014 Article No. supplements and special versions Options Motors without explosion protection Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 8 Water-cooled version 9 Air-cooled, open version with selfventilation with forcedair cooling with waterjacket cooling with heat exchanger with selfventilation with forcedair cooling 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 Special technology – encoders (continued) Mounting of a special type of encoder Y70 • and encoder designation O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Mounting of HOG 10 DN 1024 I + centrifugal switch (speed .... rpm), terminal box protection against humidity Y74 • and required speed .... rpm O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Mounting of HOG 10 DN 1024 I + Y76 • and required centrifugal switch (speed .... rpm), terminal box protection against dust speed .... rpm O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Special technology – prepared for encoder mounting Prepared for mounting of LL 861 900 220 2) 38) H78 O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Prepared for mounting of HOG 10 D 1024 I 2) 38) H80 O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Mounting of brake (incl. the brake from Stromag) 17) H47 O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Mounting of the holding brake SFB 160, 1600 Nm, 230 V, Pintsch-Bubenzer 17) J48 O. – R. O. – R. O. – R. O. – R. O. – R. O. – R. Mounting of the holding brake SFB 160 SH, 2100 Nm, 230 V, Pintsch-Bubenzer 17) J49 O. – R. O. – R. O. – R. O. – R. O. – R. O. – R. Mounting of the holding brake SFB 160 H, 2500 Nm, 230 V, Pintsch-Bubenzer 17) J56 O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. O. O. R. R. Mounting of the holding brake SFB 250 SH, 3300 Nm, 230 V, Pintsch-Bubenzer 17) J57 – O. R. – O. R. – O. R. – O. R. – O. R. – O. R. Mounting of the holding brake SFB 250 H, 4000 Nm, 230 V, Pintsch-Bubenzer 17) J58 – O. R. – O. R. – O. R. – O. R. – O. R. – O. R. Mounting of the holding brake SFB 250 H, 4000 Nm, 400 V, Pintsch-Bubenzer 17) J59 – – – – – – – – – – – – Mounting of the holding brake SFB 400 SH, 5200 Nm, 400 V, Pintsch-Bubenzer 17) J66 – – – – – – – – – – – – Mounting of the holding brake SFB 400 H, 6300 Nm, 400 V, Pintsch-Bubenzer 17) J67 – – – – – – – – – – – – Mounting of the holding brake SFB 630 SH, 8000 Nm, 400 V, Pintsch-Bubenzer 17) J68 – – – – – – – – – – – – Mounting of the holding brake SFB 630 H, 10000 Nm, 400 V, Pintsch-Bubenzer 17) J69 – – – – – – – – – – – – Special technology – brakes 11 For legends and footnotes, see Page 11/32. 11/12 Siemens D 81.8 · 04/2014 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 1L .1. . . - . . . . . - . . . . -Z 315 Frame size © Siemens AG 2014 Article No. supplements and special versions Options Motors without explosion protection Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 8 Water-cooled version 9 Air-cooled, open version with selfventilation with forcedair cooling with waterjacket cooling with heat exchanger with selfventilation with forcedair cooling 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 1L .1. . . - . . . . . - . . . . -Z 315 Frame size Special technology – prepared for brake mounting Prepared for mounting of the holding J06 brake SFB for shaft height 315 17) O. – R. O. – R. O. – R. O. – R. O. – R. O. – R. Prepared for mounting of the holding J07 brake SFB for shaft height 355 17) – – – – – – O. R. O. R. O. R. O. R. O. R. O. R. Documentation Printed German/English Operating Instructions enclosed B23 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Paintwork coat thickness measurement protocol B29 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Electrical data sheet B31 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Order specific dimension drawing B32 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Standard test schedule B34 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Balancing report B35 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Load characteristics B37 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Recommended spare parts B38 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Production schedule: Generated once B43 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Production schedule: Updated every two weeks B44 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Production schedule: Updated monthly B45 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Order-specific test schedule B48 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Starting curve (T = f(n); I = f(n)) 1) B50 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Equivalent circuit diagram B51 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Thermal torque limit curve 2) B52 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Thermally admissible duty cycle 1) B53 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Dynamic foundation load B54 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 11 Documentation languages Documentation Czech D54 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Polish D55 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Russian D56 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Japanese D57 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Danish D62 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Rumanian D71 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Italian D72 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Finnish D73 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Dutch D74 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Turkish D75 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation French D77 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Spanish D78 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Portuguese D79 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ For legends and footnotes, see Page 11/32. Siemens D 81.8 · 04/2014 11/13 © Siemens AG 2014 Article No. supplements and special versions Options Motors without explosion protection Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 8 Water-cooled version 9 Air-cooled, open version with selfventilation with forcedair cooling with waterjacket cooling with heat exchanger with selfventilation with forcedair cooling 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 Documentation languages (continued) Documentation Bulgarian D80 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Norwegian D81 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Hungarian D82 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Swedish D83 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Chinese D84 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Serbian D91 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extension of liability for defects by Q80 12 months up to a total of 24 months from initial shipment ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extension of liability for defects by Q81 18 months up to a total of 30 months from initial shipment ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extension of liability for defects by Q82 24 months up to a total of 36 months from initial shipment ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extension of liability for defects by Q83 30 months up to a total of 42 months from initial shipment ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extension of liability for defects by Q84 36 months up to a total of 48 months from initial shipment ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extension of liability for defects by Q85 48 months up to a total of 60 months from initial shipment ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extension of liability Test certificates 11 Standard test (routine test), with acceptance F01 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Visual acceptance and report handover, with acceptance F03 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Temperature-rise test, without acceptance 33) F04 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Temperature-rise test, with acceptance 33) F05 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Recording of short-circuit character- F16 istic and determination of shortcircuit losses, without acceptance 33) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Recording of short-circuit character- F17 istic and determination of shortcircuit losses, with acceptance 33) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Recording of load characteristic (T-n F18 characteristic), without acceptance 33) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Recording of load characteristic (T-n characteristic), with acceptance 33) F19 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Noise measurement in no-load operation, no noise analysis, without acceptance 33) F28 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Noise measurement in no-load operation, no noise analysis, with acceptance 33) F29 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Recording of current and torque F34 curves with torque metering shaft dur1) 34) ing starting, without acceptance ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ For legends and footnotes, see Page 11/32. 11/14 Siemens D 81.8 · 04/2014 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 1L .1. . . - . . . . . - . . . . -Z 315 Frame size © Siemens AG 2014 Article No. supplements and special versions Options Motors without explosion protection Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 8 Water-cooled version 9 Air-cooled, open version with selfventilation with forcedair cooling with waterjacket cooling with heat exchanger with selfventilation with forcedair cooling 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 1L .1. . . - . . . . . - . . . . -Z 315 Frame size Test certificates (continued) F35 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ F52 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Measurement of locked-rotor F53 torque and current, with acceptance ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Noise measurement in no-load operation, with noise analysis, without acceptance 33) F62 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Noise measurement in no-load operation, with noise analysis, with acceptance 33) F63 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Type test with heat run for horizontal F82 motors, without acceptance 33) 22) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Type test with heat run for horizontal F83 motors, with acceptance 33) 22) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Type test with heat run for vertical motors, without acceptance 33) 23) F92 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Type test with heat run for vertical motors, with acceptance 33) 23) F93 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Commissioning of the classification society by Siemens E88 – – – – ✓ ✓ ✓ ✓ – – – – Commissioning of the classification society by third party E89 – – – – ✓ ✓ ✓ ✓ – – – – Pump drive for sea water desalination plants certified according to Lloyd's Register 16) 36) E90 – – – – ✓ ✓ ✓ ✓ – – – – Recording of current and torque curves with torque metering shaft during starting, with acceptance 1) 34) Measurement of locked-rotor torque and current, without acceptance 1) 34) 1) 34) Pump drives 11 Marine non-essential service – technical design Design according to ABS for non-essential service 16) 7) X00 – – – – ✓ ✓ ✓ ✓ – – – – Design according to BV for non-essential service 16) 7) X01 – – – – ✓ ✓ ✓ ✓ – – – – Design according to CCS for non-essential service 16) 7) X02 – – – – ✓ ✓ ✓ ✓ – – – – Design according to DNV for non-essential service 16) 7) X03 – – – – ✓ ✓ ✓ ✓ – – – – Design according to GL for non-essential service 16) 7) X04 – – – – ✓ ✓ ✓ ✓ – – – – Design according to KR for non-essential service 16) 7) X05 – – – – ✓ ✓ ✓ ✓ – – – – Design according to LR for non-essential service 16) 7) X06 – – – – ✓ ✓ ✓ ✓ – – – – For legends and footnotes, see Page 11/32. Siemens D 81.8 · 04/2014 11/15 © Siemens AG 2014 Article No. supplements and special versions Options Motors without explosion protection Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 8 Water-cooled version 9 Air-cooled, open version with selfventilation with forcedair cooling with waterjacket cooling with heat exchanger with selfventilation with forcedair cooling 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 – – – ✓ ✓ ✓ ✓ – – – – Design according to BV for essential X11 service 16) 7) – – – – ✓ ✓ ✓ ✓ – – – – Design according to CCS for essential service 16) 7) X12 – – – – ✓ ✓ ✓ ✓ – – – – Design according to DNV for essential service 16) 7) X13 – – – – ✓ ✓ ✓ ✓ – – – – Design according to GL for essential X14 service 16) 7) – – – – ✓ ✓ ✓ ✓ – – – – Design according to KR for essential X15 service 16) 7) – – – – ✓ ✓ ✓ ✓ – – – – Design according to LR for essential X16 service 16) 7) – – – – ✓ ✓ ✓ ✓ – – – – Design according to ABS for essential service 16) 7) Marine essential service certification 11 Certification for the first motor ordered according to ABS for essential service 16) J70 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to ABS for essential service 16) J71 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the first motor ordered according to BV for essential service 16) J72 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to BV for essential service 16) J73 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the first motor ordered according to CCS for essential service 16) J74 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to CCS for essential service 16) J75 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the first motor ordered according to DNV for essential service 16) J76 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to DNV for essential service 16) J77 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the first motor ordered according to GL for essential service 16) J78 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to GL for essential service 16) J79 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the first motor ordered according to KR for essential service 16) J80 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to KR for essential service 16) J81 – – – – O. O. R. R. O. O. R. R. – – – – For legends and footnotes, see Page 11/32. 11/16 Siemens D 81.8 · 04/2014 455 355 – Marine essential service – technical design 400 315 455 355 400 315 455 400 355 315 455 400 355 315 455 355 400 315 455 355 X10 1L .1. . . - . . . . . - . . . . -Z 400 315 Frame size © Siemens AG 2014 Article No. supplements and special versions Options Motors without explosion protection Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 8 Water-cooled version 9 Air-cooled, open version with selfventilation with forcedair cooling with waterjacket cooling with heat exchanger with selfventilation with forcedair cooling 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to LR for essential service 16) J83 – – – – O. O. R. R. O. O. R. R. – – – – X30 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional X31 motors ordered according to ABS for essential service 16) – – – – O. O. R. R. O. O. R. R. – – – – Tests for the first motor ordered acX32 cording to BV for essential service 16) – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional motors ordered according to BV for essential service 16) X33 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the first motor ordered according to CCS for essential service 16) X34 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional X35 motors ordered according to CCS for essential service 16) – – – – O. O. R. R. O. O. R. R. – – – – Tests for the first motor ordered according to DNV for essential service 16) X36 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional X37 motors ordered according to DNV for essential service 16) – – – – O. O. R. R. O. O. R. R. – – – – Tests for the first motor ordered acX38 cording to GL for essential service 16) – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional motors ordered according to GL for essential service 16) X39 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the first motor ordered acX40 cording to KR for essential service 16) – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional motors ordered according to KR for essential service 16) X41 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the first motor ordered ac- X42 cording to LR for essential service 16) – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional motors ordered according to LR for essential service 16) – – – – O. O. R. R. O. O. R. R. – – – – 455 355 – 400 315 455 355 400 315 455 400 355 315 455 400 355 315 455 355 400 315 455 355 Certification for the first motor J82 ordered according to LR for essential 16) service 1L .1. . . - . . . . . - . . . . -Z 400 315 Frame size Marine essential service certification (continued) Marine essential service – testing Tests for the first motor ordered according to ABS for essential service 16) X43 11 Marine essential service for propulsion – technical design X20 – – – – ✓ ✓ ✓ ✓ – – – – Design according to BV for essential X21 service, propulsion 16) 7) – – – – ✓ ✓ ✓ ✓ – – – – Design according to CCS for essential service, propulsion 16) 7) X22 – – – – ✓ ✓ ✓ ✓ – – – – Design according to DNV for essential service, propulsion 16) 7) X23 – – – – ✓ ✓ ✓ ✓ – – – – Design according to ABS for essential service, propulsion 16) 7) For legends and footnotes, see Page 11/32. Siemens D 81.8 · 04/2014 11/17 © Siemens AG 2014 Article No. supplements and special versions Options Motors without explosion protection Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 8 Water-cooled version 9 Air-cooled, open version with selfventilation with forcedair cooling with waterjacket cooling with heat exchanger with selfventilation with forcedair cooling 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 – – – ✓ ✓ ✓ ✓ – – – – Design according to KR for essential X25 service, propulsion 16) 7) – – – – ✓ ✓ ✓ ✓ – – – – Design according to LR for essential X26 service, propulsion 16) 7) – – – – ✓ ✓ ✓ ✓ – – – – Marine essential service for propulsion – certification 11 Certification for the first motor ordered according to ABS for essential service, propulsion 16) N40 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to ABS for essential service, propulsion 16) N41 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the first motor ordered according to BV for essential service, propulsion 16) N42 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to BV for essential service, propulsion 16) N43 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the first motor ordered according to CCS for essential service, propulsion 16) N44 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to CCS for essential service, propulsion 16) N45 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the first motor ordered according to DNV for essential service, propulsion 16) N46 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to DNV for essential service, propulsion 16) N47 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the first motor ordered according to GL for essential service, propulsion 16) N48 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to GL for essential service, propulsion 16) N49 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the first motor ordered according to KR for essential service, propulsion 16) N50 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to KR for essential service, propulsion 16) N51 – – – – O. O. R. R. O. O. R. R. – – – – Certification for the first motor N52 ordered according to LR for essential 16) service, propulsion – – – – O. O. R. R. O. O. R. R. – – – – Certification for the second and additional motors ordered according to LR for essential service, propulsion 16) – – – – O. O. R. R. O. O. R. R. – – – – N53 For legends and footnotes, see Page 11/32. 11/18 Siemens D 81.8 · 04/2014 455 355 – Marine essential service for propulsion – technical design (continued) 400 315 455 355 400 315 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 Design according to GL for essential X24 service, propulsion 16) 7) 1L .1. . . - . . . . . - . . . . -Z 315 Frame size © Siemens AG 2014 Article No. supplements and special versions Options Motors without explosion protection Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 8 Water-cooled version 9 Air-cooled, open version with selfventilation with forcedair cooling with waterjacket cooling with heat exchanger with selfventilation with forcedair cooling 1LM1 1LQ1 1LH1 1LN1 1LL1 1LP1 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional motors ordered according to ABS for essential service, propulsion 16) X61 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the first motor ordered according to BV for essential service, propulsion 16) X62 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional motors ordered according to BV for essential service, propulsion 16) X63 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the first motor ordered according to CCS for essential service, propulsion 16) X64 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional motors ordered according to CCS for essential service, propulsion 16) X65 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the first motor ordered according to DNV for essential service, propulsion 16) X66 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional motors ordered according to DNV for essential service, propulsion 16) X67 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the first motor ordered according to GL for essential service, propulsion 16) X68 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional motors ordered according to GL for essential service, propulsion 16) X69 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the first motor ordered according to KR for essential service, propulsion 16) X70 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional motors ordered according to KR for essential service, propulsion 16) X71 – – – – O. O. R. R. O. O. R. R. – – – – Tests for the first motor ordered X72 according to LR for essential service, 16) propulsion – – – – O. O. R. R. O. O. R. R. – – – – Tests for the second and additional motors ordered according to LR for essential service, propulsion 16) – – – – O. O. R. R. O. O. R. R. – – – – O. O. R. R. O. O. R. R. – – – – O. O. R. R. O. O. R. R. O. O. R. R. 455 355 X60 400 315 455 355 400 315 455 400 355 315 455 400 355 315 455 355 400 315 455 355 Tests for the first motor ordered according to ABS for essential service, propulsion 16) 1L .1. . . - . . . . . - . . . . -Z 400 315 Frame size Marine essential service for propulsion – testing X73 11 Marine – Additional options for essential service and essential service for propulsion Motor for ship application, with higher ambient temperature and/ or use of temperature class 180 (H) utilized according to 130 (B) 16) E80 – – Tests in the presence of representatives of the customer (in addition to the inspector of the classification society) X99 O. O. R. R. – – O. O. R. R. O. O. R. R. For legends and footnotes, see Page 11/32. Siemens D 81.8 · 04/2014 11/19 © Siemens AG 2014 Article No. supplements and special versions Options Explosion-proof motors ■ Selection and ordering data Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 Water-cooled version with selfventilation with forced-air cooling with waterjacket cooling with heat exchanger 1MM1 1MQ1 1MH1 1MN1 Motor protection – winding monitoring 6 PTC thermistors for alarm and A12 tripping, without lightning arresters 6) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 2 temperature sensors KTY 84-130 A25 6 temperature sensors KTY 84-130 A27 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 6 Pt100 resistance thermometers 6) A61 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 6 Pt100 resistance thermometers, 3-wire circuit from auxiliary terminal box (option M50 or M88) 6) A64 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Motor protection – bearing monitoring 2 Pt100 screw-in resistance thermometers in basic circuit for rolling-contact bearings A72 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 2 Pt100 screw-in resistance thermometers in basic circuit for rolling-contact bearings, 3-wire circuit from auxiliary terminal box A78 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 2 Pt100 double screw-in resistance thermometers in 3-wire circuit for rolling-contact bearings A80 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ H08 – – – – – – ✓ ✓ Subsequently rotatable main terminal box 9) J12 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Larger terminal box 1XB1 631 L00 – – – – ✓ ✓ – – Undrilled entry plate L01 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Larger terminal box 1XB1 6211) 9) M58 – – – – ✓ ✓ – – PE connection without cable lug Q00 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Motor protection – other monitoring functions Leakage water detection Motor connection – terminal box 1) 9) 31) 11 Motor connection – terminal box – cable entry Cable entry from right-hand 9) L51 Cable entry from left-hand 9) L52 9) L61 Cable entry from NDE 9) L62 Cable entry from the bottom 9) L63 Cable entry from the top 9) N83 Cable entry from DE For legends and footnotes, see Page 11/32. 11/20 Siemens D 81.8 · 04/2014 455 400 355 315 455 400 355 315 455 400 355 315 455 400 1M .1. . . - . . . . . - . . . . -Z 355 315 Frame size © Siemens AG 2014 Article No. supplements and special versions Options Explosion-proof motors Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 Water-cooled version with selfventilation with forced-air cooling with waterjacket cooling with heat exchanger 1MM1 1MQ1 1MH1 1MN1 455 400 355 315 455 400 355 315 455 400 355 315 455 400 1M .1. . . - . . . . . - . . . . -Z 355 315 Frame size Motor connection – auxiliary terminal box DIN 89280 cable gland, maximum configuration 8) K57 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 6 cables protruding, 1.5 m long 1) L48 – – – – O. R. O. R. – – 6 cables protruding, 3 m long 1) L49 – – – – O. R. O. R. – – Auxiliary terminal box 1XB3020 L97 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Auxiliary terminal box 1XB9016 (cast-iron) 29) 30) M50 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Auxiliary terminal box 1XB9015 (stainless steel) 29) 30) M51 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Auxiliary terminal box 1XB9014 (aluminum) 29) 30) M88 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Anti-condensation heating for 230 V K45 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Anti-condensation heating for 115 V K46 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Anti-condensation heating for 400 V L08 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Anti-condensation heating for 500 V L09 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Standard winding; non-standard voltage 3) M1Y O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. Non-standard winding 3) M2Y – – – – – – – – Non-standard rated speed 32) N1Y O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. Design with 2 galvanically separated C21 windings for operation with converter O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. Anti-condensation heating 2) Winding modification 2) Ventilation Metal external fan K35 ✓ ✓ – – – – – – Separately driven fan with non-standard voltage 3) 16) Y81 – – O. R. O. R. – – O. R. O. R. Measuring nipple for SPM shock pulse measurement for bearing inspection 15) G50 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Shock pulse measurement, fixed sensor and distributor box H05 O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. Shock pulse measurement, complete alarm box H07 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Prepared for mounting of a vibration sensor SIPLUS CMS2000 VIB-SENSOR S01 15) H69 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Bearing design for increased cantilever forces 18) 20) K20 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Spent grease removal K41 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 11 Bearings and lubrication For legends and footnotes, see Page 11/32. Siemens D 81.8 · 04/2014 11/21 © Siemens AG 2014 Article No. supplements and special versions Options Explosion-proof motors Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 Water-cooled version with selfventilation with forced-air cooling with waterjacket cooling with heat exchanger 1MM1 1MQ1 1MH1 1MN1 Balance and vibration quantity Vibration quantity level B 5) 21) 22) K02 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Full-key balancing L68 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ K16 ✓ ✓ – – ✓ ✓ – – Shaft extension with standard dimensions, without feather keyway K42 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Non-standard cylindrical shaft extension Y55 • and identification code – – – – – – – – Anti-clockwise direction, unidirectional fan 42) K98 – ✓ – – – – – – Both directions of rotation 42) K99 – O. R. – – – – – – IP65 degree of protection 20) K50 O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. IP56 degree of protection (nonheavy-sea) 16) 20) K52 ✓ ✓ – – ✓ ✓ ✓ ✓ Pipe connection without socket on NDE from right-hand 27) K77 – – O. R. O. R. – – – – Pipe connection without socket on NDE from left-hand 27) K78 – – O. R. O. R. – – – – Pipe connection without socket on NDE from top 27) K79 – – O. R. O. R. – – – – Cooling water pipes in stainless steel M85 instead of copper – – – – ✓ ✓ – – Water connection from top K61 – – – – ✓ ✓ – – Water connection from right-hand (view from DE) K62 – – – – ✓ ✓ – – Water connection from left-hand (view from DE) K63 – – – – ✓ ✓ – – Mounting a coupling provided 5) 19) L17 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Motor mounting material for mounting on steel foundation 25) L31 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Rust-resistant screws (externally) 28) M27 O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. Flange version A660 instead of standard version 24) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Shaft Second standard shaft extension 14) 39) 40) Direction of rotation Degrees of protection Pipe connection Water connection and material 11 Mechanical options M61 For legends and footnotes, see Page 11/32. 11/22 Siemens D 81.8 · 04/2014 455 400 355 315 455 400 355 315 455 400 355 315 455 400 1M .1. . . - . . . . . - . . . . -Z 355 315 Frame size © Siemens AG 2014 Article No. supplements and special versions Options Explosion-proof motors Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 Water-cooled version with selfventilation with forced-air cooling with waterjacket cooling with heat exchanger 1MM1 1MQ1 1MH1 1MN1 455 400 355 315 455 400 355 315 455 400 355 315 455 400 1M .1. . . - . . . . . - . . . . -Z 355 315 Frame size Colors and paint finish Standard finish in RAL 7030 stone gray Unpainted (only cast-iron parts primed) K23 Special finish in RAL 7030 stone gray K26 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Standard finish in other colors Y53 • and standard finish in RAL …. – – – – – – – – Special finish in other colors Y54 • and special finish in RAL …. – – – – – – – – Second rating plate, loose K31 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extra rating plate with identification codes Y82 • and identification code – – – – – – – – C10 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Rating plate and extra rating plates Utilization Temperature class 180 (H), used acc. to 130 (B) 2) Coolant temperature and site altitude Increased air humidity/temperature with 30 to 60 g water per m3 of air C19 – – – – O. R. O. R. O. R. O. R. Increased air humidity/temperature with 60 to 100 g water per m3 of air C26 – – – – O. R. O. R. O. R. O. R. Coolant temperature –50 to +40 °C D02 O. R. O. R. O. R. O. R. – – – – Coolant temperature –40 to +40 °C D03 O. R. O. R. O. R. O. R. – – – – Coolant temperature –30 to +40 °C D04 ✓ ✓ ✓ ✓ – – – – Coolant temperature 45 °C D11 – – – – Coolant temperature 50 °C D12 – – – – Coolant temperature 55 °C D13 – – – – Coolant temperature 60 °C D14 O. R. O. R. O. R. O. R. – – – – Cooling water temperature 30 °C D15 – – – – ✓ ✓ ✓ ✓ Cooling water temperature 35 °C D16 – – – – ✓ ✓ ✓ ✓ Cooling water temperature 40 °C D17 – – – – ✓ ✓ ✓ ✓ Outdoor use with high salinity or areas with almost continuous condensation (corrosivity grade C5-M/ C5-I) E81 – – – – O. R. O. R. O. R. O. R. Outdoor use with moderate salinity (corrosivity grade C4) E82 – – – – O. R. O. R. O. R. O. R. Outdoor use with moderate salinity (corrosivity grade C3) E83 – – – – O. R. O. R. O. R. O. R. 11 For legends and footnotes, see Page 11/32. Siemens D 81.8 · 04/2014 11/23 © Siemens AG 2014 Article No. supplements and special versions Options Explosion-proof motors Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 Water-cooled version with selfventilation with forced-air cooling with waterjacket cooling with heat exchanger 1MM1 1MQ1 1MH1 1MN1 Design in accordance with standards and specifications ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Conformity statement in accordance D36 with 94/9/EG (ATEX) of an independent body for Zone 2 motors (Ex nA)16) 41) O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. IEC Ex certificate – only in combina- D37 tion with order codes M72 and M73 O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. Electrical according to NEMA MG1-12 D30 16) 41) Design according to ATEX, IEC-Ex Square load curve M ~ n2 4) 16) *) B60 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Constant load curve T = const 4) 16) B61 – – O. R. O. R. O. R. O. R. O. R. O. R. Ex nA II on VIK rating plate 11) 26) C27 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ VIK version 37) K30 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Design for Zone 22 for non-conductive dust (IP55) for mains-fed operation 1) M35 – – – – ✓ ✓ – – Design for Zone 22 for non-conductive dust (IP55) for converter-fed operation 2) 13) 16) M39 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Design for Zone 2 for mains-fed operation Ex nA II T3 according to IEC/EN 60079-15 1) M72 – – – – ✓ ✓ – – Design for Zone 2 for converter-fed operation Ex nA II T3 according to IEC/EN 60079-15 2) 13) 16) M73 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Mounting of HOG 10 D 1024 I 2) 38) H73 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Mounting of HOG 10 DN 2048 2) 38) H83 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Mounting of HOG 11 DN 2048 2) 38) H84 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Mounting of HOG 11 DN 1024 I (16 mm) with special anti-corrosion protection 2) 38) H88 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. Mounting of HOG 10 DN 1024 I with N06 terminal box/protection against dust (zero signal) 2) 38) O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. Mounting of HOG 10 D 1024 I with terminal box/protection against humidity 2) 38) N07 O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. Mounting of HOG 10 DN 1024 I with N08 terminal box/protection against dust (zero signal) 2) 38) O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. Mounting of a special type of encoder – – – – – – – – Special technology – encoders 11 Mounting of HOG 10 D 1024 I with N05 terminal box/protection against dust 2) 38) Y70 • and encoder designation For legends and footnotes, see Page 11/32. 11/24 Siemens D 81.8 · 04/2014 455 400 355 315 455 400 355 315 455 400 355 315 455 400 1M .1. . . - . . . . . - . . . . -Z 355 315 Frame size © Siemens AG 2014 Article No. supplements and special versions Options Explosion-proof motors Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 Water-cooled version with selfventilation with forced-air cooling with waterjacket cooling with heat exchanger 1MM1 1MQ1 1MH1 1MN1 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 1M .1. . . - . . . . . - . . . . -Z 315 Frame size Special technology – prepared for encoder mounting Prepared for mounting of LL 861 900 220 2) 38) H78 O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. Prepared for mounting of HOG 10 D 1024 I 2) 38) H80 O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. Printed German/English Operating Instructions enclosed B23 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Paintwork coat thickness measurement protocol B29 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Electrical data sheet B31 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Order specific dimension drawing B32 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Standard test schedule B34 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Balancing report B35 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Load characteristics B37 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Recommended spare parts B38 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Production schedule: Generated once B43 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Production schedule: Updated every two weeks B44 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Production schedule: Updated monthly B45 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Order-specific test schedule B48 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Starting curve (T = f(n); I = f(n)) 1) B50 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Equivalent circuit diagram B51 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Thermal torque limit curve 2) B52 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Thermally admissible duty cycle 1) B53 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Document – Dynamic foundation load B54 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Czech D54 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Polish D55 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Russian D56 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Japanese D57 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Danish D62 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Rumanian D71 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Italian D72 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Finnish D73 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Dutch D74 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Turkish D75 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation French D77 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Spanish D78 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Portuguese D79 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation 11 Documentation languages For legends and footnotes, see Page 11/32. Siemens D 81.8 · 04/2014 11/25 © Siemens AG 2014 Article No. supplements and special versions Options Explosion-proof motors Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 Water-cooled version with selfventilation with forced-air cooling with waterjacket cooling with heat exchanger 1MM1 1MQ1 1MH1 1MN1 Documentation languages (continued) Documentation Bulgarian D80 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Norwegian D81 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Hungarian D82 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Swedish D83 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Chinese D84 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Documentation Serbian D91 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Q80 Extension of liability for defects by 12 months up to a total of 24 months from initial shipment ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extension of liability for defects by Q81 18 months up to a total of 30 months from initial shipment ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extension of liability for defects by Q82 24 months up to a total of 36 months from initial shipment ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extension of liability for defects by Q83 30 months up to a total of 42 months from initial shipment ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extension of liability for defects by Q84 36 months up to a total of 48 months from initial shipment ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extension of liability for defects by Q85 48 months up to a total of 60 months from initial shipment ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Extension of liability Test certificates 11 Standard test (routine test), with acceptance F01 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Visual acceptance and report handover, with acceptance F03 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Temperature-rise test, without acceptance 33) F04 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Temperature-rise test, with acceptance 33) F05 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Recording of short-circuit character- F16 istic and determination of shortcircuit losses, without acceptance 33) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Recording of short-circuit character- F17 istic and determination of shortcircuit losses, with acceptance 33) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Recording of load characteristic (T-n F18 characteristic), without acceptance 33) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Recording of load characteristic (T-n characteristic), with acceptance 33) F19 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Noise measurement in no-load operation, no noise analysis, without acceptance 33) F28 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Noise measurement in no-load operation, no noise analysis, with acceptance 33) F29 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Recording of current and torque curves with torque metering shaft during starting, without acceptance F34 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ 1) 34) For legends and footnotes, see Page 11/32. 11/26 Siemens D 81.8 · 04/2014 455 400 355 315 455 400 355 315 455 400 355 315 455 400 355 1M .1. . . - . . . . . - . . . . -Z 315 Frame size © Siemens AG 2014 Article No. supplements and special versions Options Explosion-proof motors Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 Water-cooled version with selfventilation with forced-air cooling with waterjacket cooling with heat exchanger 1MM1 1MQ1 1MH1 1MN1 455 400 355 315 455 400 355 315 455 400 355 315 455 400 1M .1. . . - . . . . . - . . . . -Z 355 315 Frame size Test certificates (continued) F35 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ F52 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Measurement of locked-rotor torque and current, with acceptance 1) 34) F53 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Noise measurement in no-load operation, with noise analysis, without acceptance 33) F62 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Noise measurement in no-load operation, with noise analysis, with acceptance 33) F63 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Type test with heat run for horizontal F82 motors, without acceptance 33) 22) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Type test with heat run for horizontal F83 motors, with acceptance 33) 22) ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Type test with heat run for vertical motors, without acceptance 33) 23) F92 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Type test with heat run for vertical motors, with acceptance 33) 23) F93 ✓ ✓ ✓ ✓ ✓ ✓ ✓ ✓ Commissioning of the classification society by Siemens E88 – – – – ✓ ✓ ✓ ✓ Commissioning of the classification society by third party E89 – – – – ✓ ✓ ✓ ✓ Pump drive for sea water desalination plants certified according to Lloyd's Register 16) 36) E90 – – – – ✓ ✓ ✓ ✓ Recording of current and torque curves with torque metering shaft during starting, with acceptance 1) 34) Measurement of locked-rotor torque and current, without acceptance 1) 34) Pump drives 11 Marine non-essential service – technical design Design according to ABS for non-essential service 16) 7) X00 – – – – ✓ ✓ ✓ ✓ Design according to BV for non-essential service 16) 7) X01 – – – – ✓ ✓ ✓ ✓ Design according to CCS for non-essential service 16) 7) X02 – – – – ✓ ✓ ✓ ✓ Design according to DNV for non-essential service 16) 7) X03 – – – – ✓ ✓ ✓ ✓ Design according to GL for non-essential service 16) 7) X04 – – – – ✓ ✓ ✓ ✓ Design according to KR for non-essential service 16) 7) X05 – – – – ✓ ✓ ✓ ✓ Design according to LR for non-essential service 16) 7) X06 – – – – ✓ ✓ ✓ ✓ Marine essential service – technical design Design according to ABS for essential service 16) 7) X10 – – – – ✓ ✓ ✓ ✓ Design according to BV for essential service 16) 7) X11 – – – – ✓ ✓ ✓ ✓ Design according to CCS for essential service 16) 7) X12 – – – – ✓ ✓ ✓ ✓ For legends and footnotes, see Page 11/32. Siemens D 81.8 · 04/2014 11/27 © Siemens AG 2014 Article No. supplements and special versions Options Explosion-proof motors Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 Water-cooled version with selfventilation with forced-air cooling with waterjacket cooling with heat exchanger 1MM1 1MQ1 1MH1 1MN1 Marine essential service – technical design (continued) Design according to DNV for essential service 16) 7) X13 – – – – ✓ ✓ ✓ ✓ Design according to GL for essential service 16) 7) X14 – – – – ✓ ✓ ✓ ✓ Design according to KR for essential service 16) 7) X15 – – – – ✓ ✓ ✓ ✓ Design according to LR for essential service 16) 7) X16 – – – – ✓ ✓ ✓ ✓ Marine essential service – certification 11 Certification for the first motor ordered according to ABS for essential service16) J70 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to ABS for essential service 16) J71 – – – – O. R. O. R. O. R. O. R. Certification for the first motor ordered according to BV for essential service16) J72 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to BV for essential service 16) J73 – – – – O. R. O. R. O. R. O. R. Certification for the first motor ordered according to CCS for essential service 16) J74 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to CCS for essential service 16) J75 – – – – O. R. O. R. O. R. O. R. Certification for the first motor ordered according to DNV for essential service 16) J76 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to DNV for essential service 16) J77 – – – – O. R. O. R. O. R. O. R. Certification for the first motor ordered according to GL for essential service16) J78 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to GL for essential service 16) J79 – – – – O. R. O. R. O. R. O. R. Certification for the first motor ordered according to KR for essential service16) J80 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to KR for essential service 16) J81 – – – – O. R. O. R. O. R. O. R. Certification for the first motor ordered according to LR for essential service16) J82 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to LR for essential service 16) J83 – – – – O. R. O. R. O. R. O. R. For legends and footnotes, see Page 11/32. 11/28 Siemens D 81.8 · 04/2014 455 400 355 315 455 400 355 315 455 400 355 315 455 400 1M .1. . . - . . . . . - . . . . -Z 355 315 Frame size © Siemens AG 2014 Article No. supplements and special versions Options Explosion-proof motors Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 Water-cooled version with selfventilation with forced-air cooling with waterjacket cooling with heat exchanger 1MM1 1MQ1 1MH1 1MN1 455 400 355 315 455 400 355 315 455 400 355 315 455 400 1M .1. . . - . . . . . - . . . . -Z 355 315 Frame size Marine essential service – testing Tests for the first motor ordered according to ABS for essential service 16) X30 – – – – O. R. O. R. O. R. O. R. Tests for the second and additional X31 motors ordered according to ABS for essential service 16) – – – – O. R. O. R. O. R. O. R. Tests for the first motor ordered X32 according to BV for essential service – – – – O. R. O. R. O. R. O. R. 16) Tests for the second and additional motors ordered according to BV for essential service 16) X33 – – – – O. R. O. R. O. R. O. R. Tests for the first motor ordered according to CCS for essential service 16) X34 – – – – O. R. O. R. O. R. O. R. Tests for the second and additional motors ordered according to CCS for essential service 16) X35 – – – – O. R. O. R. O. R. O. R. Tests for the first motor ordered according to DNV for essential service 16) X36 – – – – O. R. O. R. O. R. O. R. Tests for the second and additional motors ordered according to DNV for essential service 16) X37 – – – – O. R. O. R. O. R. O. R. Tests for the first motor ordered acX38 cording to GL for essential service 16) – – – – O. R. O. R. O. R. O. R. Tests for the second and additional motors ordered according to GL for essential service 16) X39 – – – – O. R. O. R. O. R. O. R. Tests for the first motor ordered acX40 cording to KR for essential service 16) – – – – O. R. O. R. O. R. O. R. Tests for the second and additional motors ordered according to KR for essential service 16) X41 – – – – O. R. O. R. O. R. O. R. Tests for the first motor ordered X42 according to LR for essential service – – – – O. R. O. R. O. R. O. R. – – – – O. R. O. R. O. R. O. R. 11 16) Tests for the second and additional motors ordered according to LR for essential service 16) X43 Marine essential service for propulsion – technical design Design according to ABS for essential service, propulsion 16) 7) X20 – – – – ✓ ✓ ✓ ✓ Design according to BV for essential service, propulsion 16) 7) X21 – – – – ✓ ✓ ✓ ✓ Design according to CCS for essential service, propulsion 16) 7) X22 – – – – ✓ ✓ ✓ ✓ Design according to DNV for essential service, propulsion 16) 7) X23 – – – – ✓ ✓ ✓ ✓ Design according to GL for essential service, propulsion 16) 7) X24 – – – – ✓ ✓ ✓ ✓ Design according to KR for essential service, propulsion 16) 7) X25 – – – – ✓ ✓ ✓ ✓ Design according to LR for essential X26 service, propulsion 16) 7) – – – – ✓ ✓ ✓ ✓ For legends and footnotes, see Page 11/32. Siemens D 81.8 · 04/2014 11/29 © Siemens AG 2014 Article No. supplements and special versions Options Explosion-proof motors Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 Water-cooled version with selfventilation with forced-air cooling with waterjacket cooling with heat exchanger 1MM1 1MQ1 1MH1 1MN1 Marine essential service for propulsion – certification 11 Certification for the first motor ordered according to ABS for essential service, propulsion 16) N40 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to ABS for essential service, propulsion 16) N41 – – – – O. R. O. R. O. R. O. R. Certification for the first motor ordered according to BV for essential service, propulsion 16) N42 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to BV for essential service, propulsion 16) N43 – – – – O. R. O. R. O. R. O. R. Certification for the first motor ordered according to CCS for essential service, propulsion 16) N44 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to CCS for essential service, propulsion 16) N45 – – – – O. R. O. R. O. R. O. R. Certification for the first motor ordered according to DNV for essential service, propulsion 16) N46 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to DNV for essential service, propulsion 16) N47 – – – – O. R. O. R. O. R. O. R. Certification for the first motor ordered according to GL for essential service, propulsion 16) N48 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to GL for essential service, propulsion 16) N49 – – – – O. R. O. R. O. R. O. R. Certification for the first motor ordered according to KR for essential service, propulsion 16) N50 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to KR for essential service, propulsion 16) N51 – – – – O. R. O. R. O. R. O. R. Certification for the first motor ordered according to LR for essential service, propulsion 16) N52 – – – – O. R. O. R. O. R. O. R. Certification for the second and additional motors ordered according to LR for essential service, propulsion 16) N53 – – – – O. R. O. R. O. R. O. R. Marine essential service for propulsion Tests for the first motor ordered according to ABS for essential service, propulsion 16) X60 – – – – O. R. O. R. O. R. O. R. Tests for the second and additional motors ordered according to ABS for essential service, propulsion 16) X61 – – – – O. R. O. R. O. R. O. R. Tests for the first motor ordered according to BV for essential service, propulsion 16) X62 – – – – O. R. O. R. O. R. O. R. For legends and footnotes, see Page 11/32. 11/30 Siemens D 81.8 · 04/2014 455 400 355 315 455 400 355 315 455 400 355 315 455 400 1M .1. . . - . . . . . - . . . . -Z 355 315 Frame size © Siemens AG 2014 Article No. supplements and special versions Options Explosion-proof motors Special versions Additional identification code -Z with order code and plain text if required Catalog section 4 5 6 Air-cooled, enclosed version 7 Water-cooled version with selfventilation with forced-air cooling with waterjacket cooling with heat exchanger 1MM1 1MQ1 1MH1 1MN1 455 400 355 315 455 400 355 315 455 400 355 315 455 400 1M .1. . . - . . . . . - . . . . -Z 355 315 Frame size Marine essential service for propulsion (continued) Tests for the second and additional motors ordered according to BV for essential service, propulsion 16) X63 – – – – O. R. O. R. O. R. O. R. Tests for the first motor ordered according to CCS for essential service, propulsion 16) X64 – – – – O. R. O. R. O. R. O. R. Tests for the second and additional motors ordered according to CCS for essential service, propulsion 16) X65 – – – – O. R. O. R. O. R. O. R. Tests for the first motor ordered according to DNV for essential service, propulsion 16) X66 – – – – O. R. O. R. O. R. O. R. Tests for the second and additional motors ordered according to DNV for essential service, propulsion 16) X67 – – – – O. R. O. R. O. R. O. R. Tests for the first motor ordered according to GL for essential service, propulsion 16) X68 – – – – O. R. O. R. O. R. O. R. Tests for the second and additional motors ordered according to GL for essential service, propulsion 16) X69 – – – – O. R. O. R. O. R. O. R. Tests for the first motor ordered according to KR for essential service, propulsion 16) X70 – – – – O. R. O. R. O. R. O. R. Tests for the second and additional motors ordered according to KR for essential service, propulsion 16) X71 – – – – O. R. O. R. O. R. O. R. Tests for the first motor ordered X72 according to LR for essential service, 16) propulsion – – – – O. R. O. R. O. R. O. R. Tests for the second and additional motors ordered according to LR for essential service, propulsion 16) X73 – – – – O. R. O. R. O. R. O. R. E80 – – – – O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. O. R. 11 Special operating conditions Motor for ship application, with higher ambient temperature and/or use of temperature class 180 (H) utilized according to 130 (B) 16) Tests in presence of representatives X99 of the customer (in addition to the inspector of the classification society) For legends and footnotes, see Page 11/32. Siemens D 81.8 · 04/2014 11/31 © Siemens AG 2014 Article No. supplements and special versions Options Explosion-proof motors Standard version Without additional charge ✓ With additional charge • This order code only determines the price of the version – additional plain text is required. O. R. On request – Not possible 11 1) For DOL motors only. 2) For VSD motors only. 3) The following information is required in plain text when ordering: Rated output, voltage (for DOL motors: line voltage, for VSD motors: rated motor voltage), frequency and circuit. 4) The following information is required in plain text when ordering: torque and speed/frequency control range. Ordering is only possible in combination with order codes M72, M73, M35 or M39. 5) Not available in combination with order code K16 or K20. 6) The standard temperature sensors (KTY) are omitted. If KTY and PTC thermistors or Pt100 are required in combination, specify this in the order in plain text. A combination of order codes A25 and A12; A25 and A61 or A25 and A64 is available on request at an additional charge. 7) Only in combination with the stainless steel auxiliary terminal box (order code M51). 8) Only available for standard cable entry. Special cable entry incl. cable glands on request. 9) Only available for admissible mounting positions, see Page 2/12. 10) Order code K06 only in combination with order codes L00 and M58. 11) Not available in combination with order code K30. 12) Not available in combination with order code K50. 13) Order code B60 or B61 must be ordered additionally. 14) Only available for IM B3, IM V5, IM V6, IM V15 and IM V1 types of construction (14th position of Article No.: A, C, D, E, J). Not available in combination with encoder mounting. 27) Specify identical mounting position of pipe connection by selecting the order code and Article No. (16th position of Article No.: 2, 3 or 4). 28) For 1.Q1-, 1.N1 and 1LP motors, only available for the main motor. Not available for the separately driven fan motor. 29) For 1.M1-, 1.Q1-, 1LL1- and 1LP1 motors, only available with the terminal box position codes (15th position of Article No.) A to F and the separately driven fan/heat exchanger position code (16th position of Article No.) 0 to 4 with the following exceptions: A2; B3 and C4. The position of the air outlets or the separately driven fan results in constraints. For more information about possible combinations, refer to the DT Configurator selection tool at: www.siemens.com/dtconfigurator. 30) For 1.N1 motors, constraints exist with regard to the terminal box position (15th position of the Article No.) and the separately driven fan/heat exchanger position (16th position of Article No.). For more information about possible combinations, refer to the DT Configurator selection tool at: www.siemens.com/dtconfigurator. 31) Only available with 15th position of Article No.: A to F (terminal box position). 32) The rated speed must be specified in plain text in the order. If the rated motor voltage corresponds to the catalog version, the required rated output must be specified in addition. If the rated motor voltage does not correspond to the catalog version, M1Y or M2Y must be ordered in addition, and the required rated output must be specified there. 33) Testing is performed with sinusoidal infeed. Only available for an electrical rated frequency below 70 Hz. 34) Testing is performed on the supply system. Only available for an electrical rated frequency of 50 Hz. 35) Only available for 1LM1 motors in 4-pole version, type of construction IM B3, terminal box position code (15th position of Article No.) A, B, or C, line voltage 400 V, 50 Hz and 460 V, 60 Hz. Only the following order codes can be ordered in combination with the preferred motors: A12, A61, A72, G50, H70, H73, K45, K46, K57, L00, L97, Y53. 36) Industry solution for pump drive certified according to Lloyds Register LR-T-3601 (Rev. 9 of August 2008 "Electric motors higher than 100 hp") and LR-T-3601 (Rev. 8 of August 2008 "Vertical electric motors higher than 100 hp"). Only combinations of order codes E88 + E90 or E89 + E90 can be ordered. 37) Version of motors for Zone 2 without Ex nA II marking. For Ex nA II marking, order code C27 is required in addition. Ex motors for converter-fed operation are derated as compared to the non-Ex motors and temperature class 155 (F) is no longer fully utilized. For utilization according to temperature class 130 (B), in accordance with VIK recommendation, order code C10 is additionally required. 15) Only available with 16th position of Article No.: 0, 1, 2 or 5 (separately driven fan/heat exchanger position). 16) Not available for separately driven fan unit axial on NDE side (16th position of Article No.: 1). 17) Only for IM B3 and IM B35 type of construction (14th position of Article No.: A, K). 18) Only for IM B3 type of construction (14th position of Article No.: A). 19) Only for IM B3, IM V5 and IM V6 types of construction (14th position of Article No.: A, C, D). 20) Only for rated speeds below 3000 rpm (13th position of Article No.: 1, 2, 3, 4, 6, 7, 8). 21) Not available for rated speed of 3600 rpm (13th position of Article No.: 5). 22) Only for IM B3, IM B5 with support foot and IM B35 types of construction (14th position of Article No.: A, F, K). 38) 23) Only available for IM V5, IM V6, IM V15 and IM V1 types of construction (14th position of Article No.: C, D, G, J). Order code L97 is included in the scope of supply in the case of 1.Q1, 1LP1 and 1.N1. 39) Not available in combination with order code K20. 24) Only available for IM V15, IM V1 and IM B35 types of construction (14th position of Article No.: E, G, J, K). Not available for rated speeds of 1800 rpm, 3000 rpm, 3600 rpm (13th position of Article No.: 1, 5, 6). 40) For motors with the 1.M1 and 1LL1 cooling methods, the maximum torque for the second shaft extension is reduced by 50 %. 41) 25) As a variation from the standard, only terminal boxes 1XB1 621 and 1XB1 631 are available. Only available for IM B3 and IM B35 types of construction (14th position of Article No.: A, K). 42) 26) Only available for frame size 355 in combination with rated speed of 3000 rpm (13th position of Article No.: 1). Ex nA II marking is on a separate plate. *) M = Torque 11/32 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Application-specific motors 12/2 12/2 12/3 12/4 12/4 12/5 12/5 12/5 12/5 12/5 12 12/7 12/7 12/7 12/7 12/7 12/7 12/8 Marine applications Overview • Classification societies Benefits Application Technical specifications • Housing design • Water cooling • Motor connection • Specifications of the individual classification societies with order codes for ordering SIMOTICS FD motors in marine design • Temperature class and coolant temperature • Rating plate and acceptance test certificate • Degree of protection • Winding and motor protection • Paint finish • Recommended special versions More information • Ordering notes • Ordering examples 12/10 12/10 12/10 12/10 12/10 Chemical industry Overview • VIK version Application • Options for special environments 12/11 12/11 12/11 12/11 Water & waste water Overview Application • Product range for the water & waste water option packages • Offer and ordering processes for option package • Technical content of option package • Essential additional options • Additional option recommended by the manufacturer 12/6 12/7 12/11 12/12 12/12 12/12 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Application-specific motors Marine applications ■ Overview SIMOTICS FD (air-cooled and water-cooled) motors in marine design have been developed for operation below deck onboard ships. Motors intended for on deck operation or for offshore applications must be explicitly ordered using an additional order code (Article No. with additional identification code -Z and order code). The reason for this is that in these cases special measures are required. The thermal utilization of the motors is matched to the generally higher ambient temperatures onboard ship. If the application demands compliance with additional regulations, such as explosion protection, the appropriate motor series must be chosen. The motors onboard ships are subdivided into three classes of importance by the marine classification societies in collaboration with customers, depending on the application: • "Essential Service for Propulsion" or also "Primary Essential Service" • "Essential Service" or also "Secondary Essential Service" or "Important Service" • "Non-Essential Service" or also "Non-Important Service" As the assignment of a drive to one of the importance classes has a direct impact on the scope of the marine options, this must be known when ordering the motor. The following services of the motor manufacturer are associated with the classes: Class of importance Essential Service for Propulsion Essential Service Non-Essential Service General breakdown Drives integrated into the propulsion system of the ship. Safety-related drives whose failure must not cause loss of maneuverability of the ship, nor place onboard safety at risk. Drives and systems that are outside the responsibility of the classification societies. Typical applications Propeller drive, dynamic position- Lateral thrust units, anchor ing drives, booster drives and shaft winches, oil and ballast pumps, generators fire-fighting pumps Pumps for service water, winches, dredging pumps, fans Design In accordance with regulations of the classification society In accordance with ambient conditions of the classification society Acceptance test certificate Acceptance test certificate 3.2 according to EN 10204 Individual acceptance by classification society Will be performed. Motor is assigned an individual certificate of the clas- Not required sification society. A declaration of conformity is provided with the motor. Ordering several identical motors Differentiation between the first motor and additional ones must be real- No distinction ized when ordering using an order code. Rating plate data Information about ambient conditions of the classification society Stamp of the classification society Stamp on the shaft 2) and motor housing 12 1) Certificate is not stipulated by every classification society, but is always issued according to the internal quality standards within the scope of a routine test. 2) Provided that it is specified that the classification society supervises construction. 12/2 Siemens D 81.8 · 04/2014 Acceptance test certificate 3.2 according to EN 10204 Acceptance test certificate 3.1 according to EN 10204 1) No stamp © Siemens AG 2014 Application-specific motors Marine applications ■ Overview (continued) Classification societies Society Abbreviation Location American Bureau of Shipping ABS USA Bureau Veritas BV France China Classification Society CCS China Det Norske Veritas DNV Norway Germanischer Lloyd GL Germany Korean Register KR Korea Lloyds Register LR UK Nippon Class NK Japan Russian Maritime Register of Shipping RMRS Russia Other national classifications can be provided on request. Regulations of the individual classification societies for motors: Classification society Coolant temperature CT Admissible temperature rise limit according to the classification society Water cooling Temperature class Air cooling 130 (B) 155 (F), 155 (F), Prated ≥ 5000 kW Prated 5000 kW Rated power limit for individual acceptance test Construction supervision mandatory °C °C K K K kW kW ABS 32 50 70 95 90 ≥ 100 – BV 32 45 75 100 95 ≥ 100 ≥ 500 CCS 32 45 75 100 95 ≥ 50 ≥ 50 DNV 32 45 75 100 100 ≥ 300 – GL 32 45 75 100 100 ≥ 50 All propulsion KR 32 45 75 100 95 ≥ 7.5 – LR 32 45 70 95 90 ≥ 100 ≥ 100 NK 32 45 75 100 95 All power ratings – RMRS 32 45 75 95 95 ≥ 100 – 12 Siemens D 81.8 · 04/2014 12/3 © Siemens AG 2014 Application-specific motors Marine applications ■ Benefits • Increased corrosion protection using specially designed paint finishes is available • Open-circuit ventilated variant to IP23 is suitable for wellventilated and dry rooms • Marine motors can be supplied for use in areas to be protected against explosion of Zone 2 • In depth know-how regarding customer requirements • Worldwide service network with 24 hour service hotline for motors and converters The marine motors offer the user a number of advantages and benefits: • Cast-iron version is suitable for corrosive atmospheres especially for high humidity levels and salty air • Variable-speed drives reduce the energy consumption verifiably • Water cooling supports installation in small rooms and offers a higher output yield than air cooling for the same frame size ■ Application If marine motors are to be used on deck in especially corrosive atmospheres or in offshore applications, then they must be additionally upgraded to meet these more stringent conditions. Our marine motors are designed for use onboard ships (installed below deck or on deck under a protective cover): • Applications onboard ships as main and auxiliary drives below deck, e.g.: • Fans (air conditioning systems, refrigeration plants) • Pumps (for fire-extinguishing or ballast water, fuels, oils) • Compressors • Bow thrusters and Azimuth drives • Main propulsion drives • Booster drives and shaft generators (power take-in/ power take-off mode) • Ex motors for hazardous zones Typical applications are: • Coastal areas, e.g. oil rigs, drilling ships • Winches • Pumps • Compressors • Crane drives Offshore versions must be specifically ordered, as they require special measures. M Main drive Motor 12 Typical applications 12/4 Siemens D 81.8 · 04/2014 Gen. Diesel Pumps, fans Bow thruster Winches M G_D081_EN_00042 M © Siemens AG 2014 Application-specific motors Marine applications ■ Technical specifications Housing design SIMOTICS FD motors are designed with a rugged low-vibration cast-iron housing. Water cooling For optimum utilization of the marine environment, two watercooling concepts are available for SIMOTICS FD motors: • Conventional with air-to-water heat exchanger. In this case, the warm air is routed from within the motor to a heat exchanger. After cooling here, it is drawn back into the machine again. • The cooling water flows through a meander tube that is pressed into the stator core. The coolant is then extremely close to the points where the heat is generated and can therefore cool extremely efficiently. Both concepts support the use of fresh water and are provided with measures that prevent the ingress of water into the motor interior, e.g. use of double-pipe cooler. Cooling with seawater is possible with an air-to-water heat exchanger. There are four categories of classification-specific options: 1 Design options define the marine-compatible technical design in accordance with the definitions of the classification society in association with the international standards and practices of our engineers. 2 Certification options define the scope of the test certificates and cover all the expenses of the classification society and Siemens. 3 Test options define the scope of the individual tests for final acceptance of the motor in the presence of an inspector of the respective classification society. A class-specific type test is performed on the first motor, and a routine test is performed on all subsequent motors. 4 Additional options for variations and special conditions – specify the customer's request to participate in the tests at the factory, or to define requirements that deviate from the standards of the classification society. The options of the categories listed above are combined with each other depending on the class of importance, classification society and other conditions. Motor connection If motors are to be designed according to the specifications of several classification societies, a special inquiry is necessary. An undrilled entry plate is provided as standard, drilled entry plates with or without cable glands are available on request. Motors for Non-Essential Services All marine motors generally have an external grounding terminal. Specifications of the individual classification societies with order codes for ordering SIMOTICS FD motors in marine design SIMOTICS FD in marine design Cooling method Type designation Water-cooled motors with heat exchanger for converter-fed operation, IC86W cooling method 1LN Water-cooled motors with waterjacket cooling for mains-fed and converter-fed operation, IC71W cooling method 1LH Non-Essential Order codes for options in accordance with the classiService fication society (Article No. with additional identification code -Z and order code) ABS Air-cooled motors for converter-fed 1LM operation (self-ventilated), IC411 cooling method Air-cooled motors with mounted 1LQ separately driven fan for converterfed operation, IC416 cooling method Open-circuit ventilated motors for 1LL, 1LP converter-fed operation, IC01 and IC06 cooling method SIMOTICS FD motors for marine applications must be ordered with classification-specific options. This ensures that both the mechanical design of the motor and the tests are performed exactly in accordance with the instructions provided by the respective classification society. 1) The technical design is in accordance with the ambient operating conditions specified by the classification society. One of the marine design options must be ordered by specifying the respective order code X00, X01, X12 1), X03, X04, X05 or X06 (depending on the classification society). Acceptance inspections are not required. There is no distinction between ordering an individual motor or several motors. Technical version X00 BV CCS DNV GL KR LR X01 X12 1) X03 X04 X05 X06 Motors for Essential Services The technical design is in accordance with regulations of the classification society: Options with the order codes X10 to X16. An acceptance test certificate 3.2 according to EN 10204 and a product certificate of the classification society is provided with each motor. The options with order codes J70 to J82 (first motor), or J71 to J83 (additional motors) define the costs for certification of the motor. Depending on the classification society, the test steps are controlled by the options with order codes X30 to X42 for the first motor (even numbers) and X31 to X43 for the additional motors (uneven numbers). Non-Essential Service is handled by CCS in the same manner as Essential Service. Siemens D 81.8 · 04/2014 12/5 12 © Siemens AG 2014 Application-specific motors Marine applications ■ Technical specifications (continued) Order codes for options in accordance with the classification society (Article No. with additional identification code -Z and order code) Essential Service ABS BV CCS DNV GL KR LR X10 X11 X12 X13 X14 X15 X16 • First motor J70 J72 J74 J76 J78 J80 J82 • Additional motors J71 J73 J75 J77 J79 J81 J83 Technical version Certification Acceptance tests with classification • First motor X30 X32 X34 X36 X38 X40 X42 • Additional motors X31 X33 X35 X37 X39 X41 X43 Motors for Essential Services for Propulsion The technical design is in accordance with regulations of the classification society: Options with the order codes X20 to X26. An acceptance test certificate 3.2 according to EN 10204 and a product certificate of the classification society is provided with each motor. The options with order codes N40 to N52 (first motor), or N41 to N53 (additional motors) define the costs for certification of the motor. Depending on the classification society, the test steps are controlled by the options with order codes X60 to X72 for the first motor (even numbers) and X61 to X73 for the additional motors (uneven numbers). Order codes for options in accordance with the classification society (Article No. with additional identification code -Z and order code) BV CCS DNV GL KR LR X20 X21 X22 X23 X24 X25 X26 • First motor N40 N42 N44 N46 N48 N50 N52 • Additional motors N41 N43 N45 N47 N49 N51 N53 Certification Acceptance tests with classification • First motor X60 X62 X64 X66 X68 X70 X72 • Additional motors X61 X63 X65 X67 X69 X71 X73 Tests in the presence of representatives of the customer (in addition to the inspector of the classification society) X99 12/6 All other tests can be ordered separately via the standard options for industrial motors. They will be performed in addition to the specified measurements. You will find the complete range of options for tests in section 10 of the catalog "Article No. supplements and special versions" under "Options". Notice: Scope of design options X00 to X26 The design options include all classification-specific technical measures. These options are bundles of additional modifications and accessories which make a motor marine-compatible as well as classification-compliant and application-compatible. Temperature class and coolant temperature Standard motors and explosion-proof motors Marine motors are normally designed for a coolant temperature of CT 45 °C or a cooling water temperature of 32 °C for utilization according to temperature class 155 (F). Motors according to the ABS classification that specify CT 50 °C are an exception. For reduction factors for cooling air and water temperature, see Page 3/2. More detailed information is available on request. Technical version 12 According to regulations, the acceptance tests are performed in the presence of an inspector of the classification society. If the customer or his representative is required to be present during the tests, order code X99 must be specified. In this case, the ordering party will be informed as to the dates in the form of an invitation. If, for example, a motor according to the ABS classification is required for an ambient temperature of 45 °C, in addition to the order codes for marine options, order code D11 must also be specified. X99 ABS Order code X99: All options that can be ordered with order codes must also be ordered using these order codes. Tests in the presence of representatives of the customer (in addition to the inspector of the classification society) Essential Service for Propulsion Additional options Siemens D 81.8 · 04/2014 © Siemens AG 2014 Application-specific motors Marine applications ■ Technical specifications (continued) Rating plate and acceptance test certificate Paint finish The metal rating plate indicates the relevant classification society and the associated coolant temperature. The housings of all certified motors are stamped with the certificate number and identifier of the society or testing agency, in accordance with regulations. These stamps are in the vicinity of the rating plate. The paint thickness is greater than standard and is included in the option for the technical design. This is suitable for indoor and outdoor use under a roof or cover. The results of the acceptance test are supplied with the motor certificate and the motor. A paint finish according to EN ISO 12944-5 C5-M is used for unprotected installation on deck, especially aggressive atmospheres or offshore applications. This is part of order code E81, which upgrades a standard marine motor for these special ambient conditions. Special paint colors and increased layer thicknesses are available on request. 3~ Mot. 1LN1 222-3AB73-2AC5-Z m: 2.07 t IP 55 SIMOTICS FD IM B3 Ta: -20…+45°C Th.Cl.: NoN- xx9900006090001/2013 180(H) Util.:155(F) nmax: 3000 1/min IEC/EN 60034-1 U [V] I [A] 660 D 510 P [kW] cosφ n [1/min] f [Hz] 505 0.90 1500 50.6 Eff. 95.9% Mot. design: FOR INVERTER DUTY ONLY Line supply: 690V / 50Hz KÜHLW./COOL.WATER 115 L/MIN, 25°C Made in Germany D-90441 Nürnberg DEW0400 MAX. WASSERDRUCK / WATER PRESSURE 6 BAR G_D081_XX_00459 MARINE EQUIPMENT / CLASSIFICATION SOCIETY: DNV Recommended special versions • Rust-resistant screws (externally) – Order code M27 • Shock Pulse Measurement (SPM) nipple for monitoring the bearing vibrations for essential and non-essential motors – Order code G50 • Mounting of 2 Pt100 screw-in resistance thermometers in basic circuit for rolling-contact bearings for essential and non-essential motors – Order code A72 • IP56 degree of protection (non-heavy-sea) for protection against water jets from any direction – Order code K52 • Upgrading a marine motor for unprotected installation on deck, use in especially aggressive atmospheres or offshore applications – on request Degree of protection The degrees of protection as specified in the catalog apply. For IP56 (non-heavy sea, order code K52) the formation of ice must be avoided. Winding and motor protection To monitor the winding and, if specified by the classification society, to monitor the bearings, the motors are equipped with PTC thermistors, temperature sensors or resistance thermometers. All water-cooled motors are equipped with leak sensors as protection against leaks in the cooling circuit. The complete scope of standard accessories depends on the society and importance class. ■ More information 12 Ordering notes The fees of the classification societies for necessary authorizations, individual acceptance inspections and certificates are included in the order code. Siemens D 81.8 · 04/2014 12/7 © Siemens AG 2014 Application-specific motors Marine applications ■ More information (continued) For selection and ordering data, see sections 4 to 10 of the catalog. Ordering examples Selection criteria Requirement Structure of the Article No. 1st ordering example: 5 motors for Non-Essential Service according to GL (Germanischer Lloyd), Germany Motor type SIMOTICS FD self-ventilated, IC411 cooling method, IP55 degree of protection 1LM1■■■– ■■■■■– ■■■■ Motor series Low-noise standard version 1LM1 2 ■■– ■■■■■– ■■■■ System description Operation on SINAMICS converter with unregulated infeed 1LM1 2 2 ■– ■■■■■– ■■■■ Efficiency Premium efficiency 1LM1 2 2 3 – ■■■■■– ■■■■ Frame size 315 1LM1 2 2 3 – 3 A■■■– ■■■■ No. of poles 4-pole 1LM1 2 2 3 – 3 AB■■– ■■■■ Laminated core length average 1LM1 2 2 3 – 3 AB5 ■– ■■■■ Line voltage and frequency 690 V, 50 Hz – VSD 1LM1 2 2 3 – 3 AB5 3 – ■■■■ Rated speed 1500 rpm 1LM1 2 2 3 – 3 AB5 3 – 2 ■■■ Type of construction IM B3 1LM1 2 2 3 – 3 AB5 3 – 2 A■■ Terminal box position Standard version (terminal box on DE top) 1LM1 2 2 3 – 3 AB5 3 – 2 AA■ Separately driven fan position No separately driven fan/heat exchanger 1LM1 2 2 3 – 3 AB5 3 – 2 AA0 Special versions Technical version according to GL, CT (air) = 45 °C, temperature class 1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z 155 (F) used acc. to 155 (F) incl.: Insulated bearing at NDE, coated inter- X04 nal surfaces and special external coating with 240 µm, 3 PTC thermistors for alarm and tripping in the winding Article No. for all 5 motors 1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z X04 2nd ordering example: 5 motors for Essential Service according to BV (Bureau Veritas), France Motor type Motor of example 1 1LM1 2 2 3 – 3 AB5 3 – 2 AA0 Special versions Technical version according to BV, CT (air) = 45 °C, temperature class 1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z 155 (F) used acc. to 155 (F) incl.: Insulated bearing at NDE, coated inter- X11 nal surfaces and special external coating with 240 µm, 3 PTC thermistors for alarm and tripping in the winding 1st motor 4 additional motors 12 12/8 Certification required for first ordered motor acc. to BV 1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z X11+J72 Tests required for first ordered motor acc. to BV 1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z X11+J72+X32 Article No. for 1st motor 1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z X11+J72+X32 Technical version according to BV, CT (air) = 45 °C, temperature class 1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z 155 (F) used acc. to 155 (F) incl.: Insulated bearing at NDE, coated inter- X11 nal surfaces and special external coating with 240 µm, 3 PTC thermistors for alarm and tripping in the winding Certification required for additional ordered motors acc. to BV 1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z X11+J73 Tests required for additional ordered motors acc. to BV 1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z X11+J73+X33 Article No. for the additional 4 motors 1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z X11+J73+X33 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Application-specific motors Marine applications ■ More information (continued) Ordering examples (continued) Selection criteria Requirement Structure of the Article No. 3rd ordering example: 2 motors for Essential Service for Propulsion according to DNV (Det Norske Veritas), Norway Motor type SIMOTICS FD water-cooled, IC71W cooling method, IP55 degree of protection 1LH1 ■■■– ■■■■■– ■■■■ Motor series Low-noise standard version 1LH1 2 ■■– ■■■■■– ■■■■ System description Operation on SINAMICS converter with regulated infeed 1LH1 2 1 ■– ■■■■■– ■■■■ Efficiency Premium efficiency 1LH1 2 1 3 – ■■■■■– ■■■■ Frame size 315 1LH1 2 1 3 – 3 A■■■– ■■■■ No. of poles 4-pole 1LH1 2 1 3 – 3 AB■■– ■■■■ Laminated core length average 1LH1 2 1 3 – 3 AB5 ■– ■■■■ Line voltage and frequency 690 V, 50 Hz – VSD 1LH1 2 1 3 – 3 AB5 3 – ■■■■ Rated speed 1500 rpm 1LH1 2 1 3 – 3 AB5 3 – 2 ■■■ Type of construction IM B3 1LH1 2 1 3 – 3 AB5 3 – 2 A■■ Terminal box position Terminal box on DE right-hand 1LH1 2 1 3 – 3 AB5 3 – 2 AB■ Separately driven fan position No separately driven fan/heat exchanger 1LH1 2 1 3 – 3 AB5 3 – 2 AB0 Special versions 1st motor This option is not mandatory. Additional motor Technical version according to DNV, CT (water) = 32 °C, temperature 1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z class 155 (F) used acc. to 155 (F) incl.: Insulated bearing at NDE, X13 painted internal surfaces and external special coating of 240 µm, 6 x Pt100 in stator winding, Pt100 for monitoring the bearing temperature, cables routed externally in stainless steel hoses, heating, leakage sensor, SPM nipple Certification required for first ordered motor acc. to DNV 1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z X13+J76 Tests required for first ordered motor acc. to DNV 1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z X13+J76+X36 Tests in the presence of representatives of the customer (in addition to the inspector of the classification society) 1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z X13+J76+X36+X99 Article No. for 1st motor 1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z X13+J76+X36+X99 Technical version according to DNV, CT (water) = 32 °C, temperature 1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z class 155 (F) used acc. to 155 (F) incl.: Insulated bearing at NDE, X13 painted internal surfaces and external special coating of 240 µm, 6 x Pt100 in stator winding, Pt100 for monitoring the bearing temperature, cables routed externally in stainless steel hoses, heating, leakage sensor, SPM nipple Certification required for additional ordered motors acc. to DNV 1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z X13+J77 Tests required for additional ordered motors acc. to DNV 1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z X13+J77+X37 Article No. for the second motor 1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z X13+J77+X37 Siemens D 81.8 · 04/2014 12/9 12 © Siemens AG 2014 Application-specific motors Chemical industry ■ Overview In the chemical industry, motors are subjected to external influences in the extreme. Operation in hazardous areas and aggressive atmospheres, in particular, result in a need to protect the motor using special measures. To ensure safe and reliable operation, it is important to verify the following: • Explosion protection • Degree of protection • Ambient conditions To meet the requirements of the chemical industry, SIMOTICS FD motors are available in a large number of industry-specific versions. VIK version The recommendations of the VIK ("Verband der Industriellen Energie- und Kraftwirtschaft e. V.", the Association of the Industrial Energy and Power Industry) describe the requirements for three-phase induction motors as often required by the chemical industry: • VIK standard version: 1L.1 + order code K30 1) – "VIK" identification on rating plate. • VIK Ex n version: 1M.1 + order code K30 1) – "VIK" identification on rating plate; "Ex nA IIC T3 Gc" on an extra rating plate in accordance with Directive 94/9/EC (ATEX) Both motor versions include the technology for Zone 2 in "Non sparking" type of protection. In accordance with the technical requirements of VIK, motors can be supplied in frame sizes 315 and 355. ■ Application Options for special environments Further options for the chemical industry In the chemical industry, a wide range of different environmental conditions occur. Through a series of options, the motors can be adapted to the conditions at the installation site. Additional options are listed below that are typically required for applications in the chemical industry. Order code Characteristics Order code Characteristics M72 K26 Outdoor use: Exposure to the weather admissible, minimal chemical pollution (SO2), direct solar radiation; Special finish in RAL 7030 stone gray (corrosivity category C2) Design for Zone 2 for mains-fed operation Ex nA II T3 according to IEC/EN 60079-15 M73 Design for Zone 2 for converter-fed operation, with derating Ex nA II T3 according to IEC/EN 60079-15 M35 Design for Zone 22 for non-conductive dust (IP55) for mains-fed operation M39 Design for Zone 22 for non-conductive dust (IP55) for converter-fed operation, derating E83 Outdoor use: Municipal and industrial atmospheres, moderate chemical pollution (SO2), minimal salinity, direct exposure to weather; special finish (corrosivity category C3) K56 IP56 degree of protection (non-heavy-sea) E82 Outdoor use: Industrial areas and coastal areas with moderate salinity, direct exposure to weather, frequent condensation, special finish (corrosivity category C4) K50 IP65 degree of protection M27 Rust-resistant screws E81 Outdoor use: Coastal and offshore areas with a high level of pollution and almost continuous condensation or industrial areas with high levels of humidity or corrosive atmospheres; special finish (corrosivity category C5-M/C5-I) K35 Metal external fan M06 Special case: Sulfurous atmosphere; special finish (corrosivity category C3) 12 1) For K30, the metal external fan must be ordered with order code K35. 12/10 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Application-specific motors Water & waste water ■ Overview Siemens motors and converters ensure optimized pumping processes and maximum availability for minimum operating costs. The full benefit is realized when Siemens drive components interact as a system, because the motors and converters are perfectly tuned to each other as early as the development stage and then subjected to tests for ruggedness under real conditions. The drive systems are therefore characterized by a high level of availability and maximum efficiency. For this reason, an option package has been specially designed for the low-voltage motors of the SIMOTICS FD series in combination with a SINAMICS frequency converter for pump drives. This simplifies offer and order processing, in particular, for pump drives used in desalination plants and similar applications with certification in accordance with the Lloyds Register. Furthermore, using variable-speed drive technology, volumetric flow can be controlled much more accurately and faster than using mechanical control components for adaptation to actual demand. The advantages are, for example, noticeably higher safety and quality for drinking water from desalination plants. Variable-speed operation also opens up an enormous potential for savings which frequently results in a SINAMICS frequency converter paying for itself after just a few months of operation. ■ Application Product range for the water & waste water option packages Motor version Cooling method Motor type Frame size Operating mode Air-cooled, enclosed version with self-ventilation IC 411 1LM1 315 ... 450 VSD Air-cooled, enclosed version with forced-air cooling IC 416 1LQ1 315 ... 450 VSD Water-cooled version with water-jacket cooling IC 71W 1LH1 315 ... 450 VSD, DOL Water-cooled version with heat exchanger IC 86W 1LN1 315 ... 450 VSD Air-cooled, open version with self-ventilation IC 01 1LL1 315 ... 450 VSD Air-cooled, open version with forced-air cooling IC 06 1LP1 315 ... 450 VSD The water option package has not been approved for use in hazardous areas. Offer and ordering processes for option package The water option package has the following order code: Additional iden- Description tification code –Z with order code E90 Pump drive for seawater desalination plants certified according to Lloyds Register Commissioning of the classification society must also be specified. It is possible to specify whether Siemens or the contractual partner of Siemens should commission the classification society. The relevant order code must be specified in the order. 12 Additional iden- Description tification code –Z with order code E88 Commissioning of the classification society by Siemens E89 Commissioning of the classification society by third party Siemens D 81.8 · 04/2014 12/11 © Siemens AG 2014 Application-specific motors Water & waste water ■ Application (continued) Technical content of the option package Order code E90 comprises the following technical content: "Balancing report" document The following acceptance tests will be performed by Lloyds Register in the Siemens factory at Nuremberg: Inspection Remarks Material used Certificate of the shaft according to EN 10204-3.1 Certificate for laminated core and copper according to EN 10204-2.1 Weld seams Weld seams according to EN 287-1 Testing Welders – Welding – Part 1: steels, German version EN 287-1:2004 + A2:2006 Housing drawings Site supervision / inspection Air gap measurements No measurement, the theoretically determined value based on stator bore and rotor external diameter can be provided on request for an additional charge Rotor design Site supervision / inspection Winding version Site supervision / inspection Winding insulation Site supervision / inspection Design, balancing Site supervision / inspection Motor dimensions, feet dimensions Site supervision / inspection Axial rotor play No measurement, guaranteed value is stated in the documentation First critical speed No measurement, depending on the motor type the machines are subcritical or supercritical Paints and varnishes Certificate for layer thickness measurement Essential additional options The following options must be ordered separately when the "Water" option package is ordered: Additional iden- Description tification code –Z with order code F29 Noise measurement (in no-load operation), no noise analysis, with acceptance F53 Measurement of locked-rotor torque and current, with acceptance F59 Vibration analysis with acceptance test according to IEC 60034-14 F01 Routine test with customer acceptance test or F83 Type test with heat run for horizontal motors (IMB3), with acceptance or F93 12 Type test with heat run for vertical motors (IMV1), with acceptance Additional option recommended by the manufacturer Based on many years of experience in the field of motors, it is recommended that a special paint finish is applied to them. Additional iden- Description tification code –Z with order code K26 12/12 Special finish Siemens D 81.8 · 04/2014 13 © Siemens AG 2014 Appendix 13/2 Partners at Industry Automation and Drive Technologies 13/3 Online Services Information and Ordering in the Internet and on DVD Siemens Industry Automation and Drive Technologies in the WWW Product Selection using the Interactive Catalog CA 01 of Industry Easy Shopping with the Industry Mall Information and Download Center Social Media, Mobile Media Downloading Catalogs Social Media Mobile Media 13/3 13/3 13/3 13/4 13/4 13/4 13/5 13/5 13/8 13/9 13/9 13/9 Industry Services Your machines and plant can do more – with Industry Services. Industry Services for the entire life cycle Online Support Technical Support Spare Parts Repair Services Field Services Training Technical Consulting & Engineering Support Energy & Environmental Services Modernization & Optimization Services Plant Maintenance & Condition Monitoring Service Contracts 13/10 13/10 13/13 Indexes Subject index Index of article numbers 13/15 Metal surcharges 13/15 13/16 13/16 13/16 13/16 13/16 13/17 Explanation of the raw material/ metal surcharges Surcharge calculation Structure of the metal factor Weight method Percentage method Metal factor examples Explanation of the raw material/metal surcharges for dysprosium and neodym (rare earths) Surcharge calculation Three-month average price Structure of the metal factor Weight method Metal factor examples Values of the metal factor 13/18 13/18 13/18 13/18 Conditions of sale and delivery General Provisions Prices Additional Terms and Conditions 13/18 Export regulations 13/6 13/6 13/6 13/7 13/7 13/7 13/8 13/8 13/15 13/15 13/15 13/15 13/15 13/16 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Appendix Partners at Industry Automation and Drive Technologies At Siemens Industry Automation and Drive Technologies, more than 85 000 people are resolutely pursuing the same goal: longterm improvement of your competitive ability. We are committed to this goal. Thanks to our commitment, we continue to set new standards in automation and drive technology. In all industries – worldwide. At your service locally, around the globe for consulting, sales, training, service, support, spare parts ... on the entire Industry Automation and Drive Technologies range. Your personal contact can be found in our Contacts Database at: www.siemens.com/automation/partner You start by selecting a • Product group, • Country, • City, • Service. 13 13/2 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Appendix Online Services Information and Ordering in the Internet and on DVD ■ Siemens Industry Automation and Drive Technologies in the WWW A detailed knowledge of the range of products and services available is essential when planning and configuring automation systems. It goes without saying that this information must always be fully up-to-date. Siemens Industry Automation and Drive Technologies has therefore built up a comprehensive range of information in the World Wide Web, which offers quick and easy access to all data required. Under the address www.siemens.com/industry you will find everything you need to know about products, systems and services. ■ Product Selection Using the Interactive Catalog CA 01 of Industry Detailed information together with convenient interactive functions: The interactive catalog CA 01 covers more than 80 000 products and thus provides a full summary of the Siemens Industry Automation and Drive Technologies product base. Here you will find everything that you need to solve tasks in the fields of automation, switchgear, installation and drives. All information is linked into a user interface which is easy to work with and intuitive. After selecting the product of your choice you can order at the press of a button, by fax or by online link. Information on the interactive catalog CA 01 can be found in the Internet under www.siemens.com/automation/ca01 or on DVD. ■ Easy Shopping with the Industry Mall The Industry Mall is the electronic ordering platform of Siemens AG on the Internet. Here you have online access to a huge range of products presented in an informative and attractive way. Data transfer via EDIFACT allows the whole procedure from selection through ordering to tracking and tracing of the order to be carried out. Availability checks, customer-specific discounts and preparation of quotes are also possible. Numerous additional functions are available to support you. For example, powerful search functions make it easy to select the required products. Configurators enable you to configure complex product and system components quickly and easily. CAx data types are also provided here. Please visit the Industry Mall on the Internet under: www.siemens.com/industrymall Siemens D 81.8 · 04/2014 13/3 13 © Siemens AG 2014 Appendix Online Services Information and Download Center Social Media, Mobile Media ■ Downloading Catalogs In addition to numerous other useful documents, you can also find the catalogs listed on the back inside cover of this catalog in the Information and Download Center. Without having to register, you can download these catalogs in PDF format or increasingly as digital page-turning e-books. The filter dialog box above the first catalog displayed makes it possible to carry out targeted searches. If you enter “MD 3” for example, you will find both the MD 30.1 and MD 31.1 catalogs. If you enter “ST 70” both the ST 70 catalog and the associated news or add-ons are displayed. Visit us on the web at: www.siemens.com/industry/infocenter ■ Social Media Connect with Siemens through social media: visit our social networking sites for a wealth of useful information, demos on products and services, the opportunity to provide feedback, to exchange information and ideas with customers and other Siemens employees, and much, much more. Stay in the know and follow us on the ever-expanding global network of social media. Connect with Siemens Industry at our central access point: www.siemens.com/industry/socialmedia Or via our product pages at: www.siemens.com/automation or www.siemens.com/drives To find out more about Siemens' current social media activities visit us at: www.siemens.com/socialmedia ■ Mobile Media Discover the world of Siemens. We are also constantly expanding our offering of cross-platform apps for smartphones and tablets. You will find the current Siemens apps at the app store (iOS) or at Google Play (Android). 13 The Siemens app, for example, tells you all about the history, latest developments and future plans of the company – with informative pictures, fascinating reports and the most recent press releases. 13/4 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Appendix Industry Services Your machines and plant can do more – with Industry Services. Whether it is production or process industry – in view of rising cost pressure, growing energy costs, and increasingly stringent environmental regulations, services for industry are a crucial competitive factor in manufacturing as well as in process industries. All over the world Siemens supports its customers with product, system, and application-related services throughout the entire life cycle of a plant. Right from the earliest stages of planning, engineering, and building, all the way to operation and modernization. These services enable customers to benefit from the Siemens experts’ unique technological and product knowledge and industry expertise. Thus downtimes are reduced and the utilization of resources is optimized. The bottom line: increased plant productivity, flexibility, and efficiency, plus reduced overall costs. Discover all advantages of our service portfolio: www.siemens.com/industry-services 7HFKQLFDO&RQVXOWLQJ (QJLQHHULQJ6XSSRUW (QHUJ\ (QYLURQPHQWDO6HUYLFHV 7HFKQLFDO&RQVXOWLQJ (QJLQHHULQJ6XSSRUW (QHUJ\ (QYLURQPHQWDO6HUYLFHV 0RGHUQL]DWLRQ 2SWLPL]DWLRQ6HUYLFHV Modernization Modernization Planning Planning Online Support Technical Support Spare Parts Repair Services Field Services Training Operation Operation 7HFKQLFDO&RQVXOWLQJ (QJLQHHULQJ6XSSRUW Engineer Engineer & & Build Build (QHUJ\ (QYLURQPHQWDO6HUYLFHV 3ODQW0DLQWHQDQFH &RQGLWLRQ0RQLWRULQJ 6HUYLFH&RQWUDFWV (QHUJ\(QYLURQPHQWDO6HUYLFHV 0RGHUQL]DWLRQ2SWLPL]DWLRQ6HUYLFHV G_DA65_EN_00270 Siemens supports its clients with technology based Services across a plants entire life cycle. Siemens D 81.8 · 04/2014 13/5 13 © Siemens AG 2014 Appendix Industry Services Industry Services for the entire life cycle Online Support Online support is a comprehensive information system for all questions relating to products, systems, and solutions that Siemens has developed for industry over time. With more than 300,000 documents, examples and tools, it offers users of automation and drive technology a way to quickly find up-to-date information. The 24-hour service enables direct, central access to detailed product information as well as numerous solution examples for programming, configuration and application. The content, in six languages, is increasingly multimediabased – and now also available as a mobile app. Online support’s “Technical Forum” offers users the opportunity to share information with each other. The “Support Request” option can be used to contact Siemens’ technical support experts. The latest content, software updates, and news via newsletters and Twitter ensure that industry users are always up to date. www.siemens.com/industry/onlinesupport Online Support App Using the Online Support app, you can access over 300,000 documents covering all Siemens industrial products – anywhere, any time. Regardless of whether you need help implementing your project, fault-finding, expanding your system or are planning a new machine. The search function retrieves product information and articles and supports you with a personalized suggestion list. You can find your favorite pages – articles you need frequently – under “mySupport”. You also receive selected news on new functions, important articles or events in the News section. You have access to FAQs, manuals, certificates, characteristics curves, application examples, product notices (e.g. announcements of new products) and information on successor products in the event that a product is discontinued. Just scan the product code printed on the product directly using the camera of your mobile device to immediately see all technical information available on this product at a glance. The graphical CAx information (3D model, circuit diagrams or EPLAN macros) is also displayed. You can forward this information to your workplace using the e-mail function. Scan the QR code for information on our Online Support app. The app is available free of charge from the Apple App Store (iOS) or from Google Play (Android). www.siemens.com/industry/onlinesupportapp Technical Support 13 The ability to quickly analyze system and error messages and take appropriate action are key factors in ensuring that plants run safely and efficiently. Questions can arise at any time and in any industry, whether it’s an individual product or a complete automation solution. Siemens technical support offers individual technical assistance in matters related to functionality, how to operate, applications, and fault clearance in industrial products and systems – at any time and globally, over the phone, by email, or via remote access. Experienced experts from Siemens answer incoming questions promptly. Depending on the requirements, they first consult specialists in the areas of development, on-site services, and sales. Technical support is also available for discontinued products that are no longer available. Using the support request number, any inquiry can be clearly identified and systematically tracked. http://support.automation.siemens.com/WW/view/en/16605032 13/6 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Appendix Industry Services Industry Services for the entire life cycle Spare Parts Drive and automation systems must be available at all times. Even a single missing spare part can bring the entire plant to a standstill – and result in substantial financial losses for the operator. The spare parts services from Siemens protects against such losses – with the aid of quickly available, original spare parts that ensure smooth interaction with all other system components. Spare parts are kept on hand for up to ten years; defective parts can be returned. For many products and solutions, individual spare parts packages ensure a preventive stock of spare parts on-site. The spare parts services is available around the world and around the clock. Optimum supply chain logistics ensure that replacement components reach their destination as quickly as possible. Siemens’ logistics experts take care of planning and management as well as procurement, transportation, customs handling, warehousing, and complete order management for spare parts. http://support.automation.siemens.com/WW/view/en/43502238 Repair Services Reliable electrical and electronic equipment is crucial for operating continuous processes. That is why it is essential that motors and converters always undergo highly specialized repair and maintenance. Siemens offers complete customer and repair services – on site and in repair centers – as well as technical emergency services worldwide. The repair services include all measures necessary to quickly restore the functionality of defective units. In addition, services such as spare parts logistics, spare parts storage and rapid manufacturing are available to plant operators in all verticals. With a global network of certified repair shops operated by Siemens as well as third parties, Siemens handles the maintenance and overhaul of motors, converters, and other devices as an authorized service partner. http://support.automation.siemens.com/WW/view/en/43512848 Field Services It’s a top priority in all industries: the availability of plants and equipment. Siemens offers specialized maintenance services such as inspection and upkeep as well as rapid fault clearance in industrial plants – worldwide, continuously, and even with emergency services as needed. The services include startup as well as maintenance and fault clearance during operation. The startup service includes checking the installation, function tests, parameterization, integration tests for machines and plants, trial operation, final acceptance, and employee training. All services, including remote maintenance of drives, are also available as elements of customized service contracts. 13 http://support.automation.siemens.com/WW/view/en/66012486 Siemens D 81.8 · 04/2014 13/7 © Siemens AG 2014 Appendix Industry Services Industry Services for the entire life cycle Training Increasingly, up-to-date knowledge is becoming a determining factor in success. One of the key resources of any company is well-trained staff that can make the right decision at the right moment and take full advantage of the potential. With SITRAIN – Training for Industry, Siemens offers comprehensive advanced training programs. The technical training courses convey expertise and practical knowledge directly from the manufacturer. SITRAIN covers Siemens’ entire product and system portfolio in the field of automation and drives. Together with the customer, Siemens determines the company’s individual training needs and then develops an advanced training program tailored to the desired requirements. Additional services guarantee that the knowledge of all Siemens partners and their employees is always up-to-date. http://support.automation.siemens.com/WW/view/en/43514324 Technical Consulting & Engineering Support The efficiency of plants and processes leads to sustainable economic success. Individual services from Siemens help save substantial time and money while also guaranteeing maximum safety. Technical consulting covers the selection of products and systems for efficient industrial plants. The services include planning, consulting, and conceptual design as well as product training, application support, and configuration verification – in all phases of a plant’s lifecycle and in all questions related to product safety. Engineering support offers competent assistance throughout the entire project, from developing a precise structure for startup to product-specific preparation for implementation as well as support services in areas such as prototype development, testing and acceptance. Energy & Environmental Services 13 Efficient energy use and resource conservation – these top sustainability concerns pay off – both for the environment and for companies. Siemens offers integrated solutions that unlock all technical and organizational potential for successful environmental management. Customized consulting services are aimed at sustainably lowering the cost of energy and environmental protection and thus increasing plant efficiency and availability. The experts provide support in the conceptual design and implementation of systematic solutions in energy and environmental management, enabling maximum energy efficiency and optimized water consumption throughout the entire company. Improved data transparency makes it possible to identify savings potential, reduce emissions, optimize production processes, and thereby noticeably cut costs. http://support.automation.siemens.com/WW/view/en/42350774 13/8 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Appendix Industry Services Industry Services for the entire life cycle Modernization & Optimization Services High machine availability, expanded functionality and selective energy savings – in all industries, these are decisive factors for increasing productivity and lowering costs. Whether a company wants to modernize individual machines, optimize drive systems, or upgrade entire plants, Siemens’ experts support the projects from planning to commissioning. Expert consulting and project management with solution responsibility lead to security and make it possible to specifically identify savings potential in production. This secures investments over the long term and increases economic efficiency in operation. http://support.automation.siemens.com/WW/view/en/66005532 Plant Maintenance & Condition Monitoring Modern industrial plants are complex and highly automated. They must operate efficiently in order to ensure the company’s competitive strength. In addition, the steadily increasing networking of machines and plants require consistent security concepts. Maintenance and status monitoring as well as the implementation of integrated security concepts by Siemens’ experts support optimum plant use and avoid downtime. The services include maintenance management as well as consulting on maintenance concepts, including the complete handling and execution of the necessary measures. Complete solutions also cover remote services, including analysis, remote diagnosis, and remote monitoring. These are based on the Siemens Remote Services platform with certified IT security. Service Contracts Making maintenance costs calculable, reducing interfaces, speeding up response times, and unburdening the company’s resources – the reduced downtimes that these measures achieve increase the productivity of a plant. Service contracts from Siemens make maintenance and repairs more cost-effective and efficient. The service packages include local and remote maintenance for a system or product group in automation and drive technology. Whether you need extended service periods, defined response times, or special maintenance intervals, the services are compiled individually and according to need. They can be adjusted flexibly at any time and used independently of each other. The expertise of Siemens’ specialists and the capabilities of remote maintenance thus ensure reliable and fast maintenance processes throughout a plant’s entire lifecycle. 13 http://support.automation.siemens.com/WW/view/en/65961857 Siemens D 81.8 · 04/2014 13/9 © Siemens AG 2014 Appendix Indexes Subject index A Additional axial load for motors in basic version .......................................2/14 Additional option recommended by the manufacturer – Water & waste water ................................................................................12/12 Additional Terms and Conditions.............................................................13/18 Admissible cantilever forces at 50 Hz for motors with reinforced bearings....................................................................................2/15 Ambient conditions ......................................................................................3/2 Answers for industry .......................................................................................2 Anti-freeze..................................................................................................3/12 Appendix ...................................................................................................13/1 Applicable standards and specifications ....................................................2/5 Application.............................................................................10/4, 12/4, 12/11 Application of SIMOTICS FD motor series...................................................1/4 Application-specific motors .......................................................................12/1 Article No. supplements and special versions ..........................................11/1 Article number code ....................................................................................1/6 Assignment of coupling types to SIMOTICS FD motors............................3/17 Axial load, additional, for motors in basic version .....................................2/14 B Bearing assignment...................................................................................2/13 Bearing currents, reducing ..........................................................................2/7 Bearing lifetime (nominal lifetime)..............................................................2/13 Bearing system ..........................................................................................2/13 Bearings.....................................................................................................2/13 Benefits .............................................................................................10/4, 12/4 Benefits of SIMOTICS FD motor series........................................................1/4 Biocides .....................................................................................................3/12 13 C Calculation of the start-up time for direct-on-line starting .........................2/10 Cantilever forces, admissible, at 50 Hz for motors with reinforced bearings....................................................................................2/15 Catalog versions ..........................................................................................3/8 Catalog versions and special versions........................................................3/8 Catalogs for Industry Automation, Drive Technologies and Low-Voltage Power Distribution ................................................................... U3 Certification – Explosion-proof motors.......................................................10/3 Chemical industry ....................................................................................12/10 Classification of zones – Explosion-proof motors ......................................10/2 Classification societies – Marine motors....................................................12/3 Condition monitoring system .....................................................................3/13 Conditions of sale and delivery ...............................................................13/18 Configuring ..................................................................................................3/2 Configuring the motor ..................................................................................3/2 Connection and terminal boxes.................................................................2/12 Terminal box mounting positions ...............................................................2/12 Terminal box position .................................................................................11/4 Converter-fed (1MM1, 1MH1, 1MQ1, 1MN1) or mains-fed operation (1LH1) – Explosion-proof motors ...............................................10/5 Coolant temperature – Explosion-proof motors .........................................10/7 Cooling circuit in the application ...............................................................3/11 Cooling water quality .................................................................................3/11 Couplings...................................................................................................3/14 13/10 Siemens D 81.8 · 04/2014 D Definite Purpose – SIMOTICS DP................................................................ 1/2 Design ......................................................................................................... 2/4 Dimensions ................................................... 4/22, 5/32, 6/34, 7/12, 8/12, 9/22 Dimensions Terminal boxes.......................... 4/24, 5/35, 6/36, 7/14, 8/14, 9/25 Dimensions Flanges ..................................... 4/23, 5/34, 6/35, 7/13, 8/13, 9/24 Dimensions Motors 1LH1/1MH1................................................................ 6/34 Dimensions Motors 1LL1 ........................................................................... 8/12 Dimensions Motors 1LM1/1MM1 ............................................................... 4/22 Dimensions Motors 1LN1/1MN1................................................................ 7/12 Dimensions Motors 1LP1........................................................................... 9/22 Dimensions Motors 1LP1 axially mounted equipment unit ....................... 9/23 Dimensions Motors 1LP1 radially mounted equipment unit ...................... 9/22 Dimensions Motors 1LQ1/1MQ1 axially mounted equipment unit ............ 5/33 Dimensions Motors 1LQ1/1MQ1 radially mounted equipment unit........... 5/32 Downloading Catalogs .............................................................................. 13/4 Duty types ................................................................................................... 3/2 E Easy Shopping with the Industry Mall ....................................................... 13/3 EMC ........................................................................................................... 3/10 Energy & Environmental Services ............................................................. 13/8 Engineering the drive system ...................................................................... 3/3 Engineering the drive system – detail level 2 .............................................. 3/6 Essential additional options – Water & waste water ................................ 12/12 Explanation of the raw material/metal surcharges .................................. 13/15 Explanation of the raw material/metal surcharges for dysprosium and neodym (rare earths)........................................................................ 13/16 Explosion Protected – SIMOTICS XP........................................................... 1/2 Explosion-proof motors.............................................................................. 10/1 Explosion-proof motors – Technical Information ....................................... 10/1 Export regulations ................................................................................... 13/18 F Field Services ............................................................................................ 13/7 FLENDER couplings – Part of the drive system ........................................ 3/14 Flexible Duty – SIMOTICS FD...................................................................... 1/2 Forced-air cooled motors – enclosed version ............................................. 5/1 Forced-air cooled motors – open version.................................................... 9/1 Forced-air cooling ....................................................................................... 2/7 G General information – Engineering the drive system .................................. 3/3 General information – Explosion-proof motors .......................................... 10/4 General Provisions................................................................................... 13/18 General Purpose – SIMOTICS GP ............................................................... 1/2 General technical specifications ................................................................. 1/5 Grease lifetime.................................................................................... 2/9, 2/14 H Heat exchanger position ........................................................................... 11/5 High Torque – SIMOTICS HT ....................................................................... 1/2 Horizontal integration ..................................................................................... 8 Housing design – Marine motors .............................................................. 12/5 I Index of article numbers.......................................................................... 13/13 Indexes .................................................................................................... 13/10 Industry Services....................................................................................... 13/5 Industry Services for the entire life cycle .................................................. 13/6 Information and Download Center Social Media, Mobile Media............... 13/4 Information and Ordering in the Internet and on DVD .............................. 13/3 Inhibitors, anti-freeze, biocides ................................................................. 3/12 Insulated bearings for converter-fed operation......................................... 2/14 Insulation ..................................................................................................... 2/6 Integrated Drive Systems ............................................................................... 8 Integration in the automation technology ....................................................... 8 Introduction.................................................................................................. 1/1 © Siemens AG 2014 Appendix Indexes Subject index L Lifecycle integration........................................................................................8 Load, mechanical ........................................................................................2/9 Lubrication .................................................................................................2/13 M Marine applications ...................................................................................12/2 Materials in the motor cooling circuit .........................................................3/11 Materials used in the motor cooling circuit ................................................3/11 Maximum overload torques .........................................................................2/8 Mechanical limit speed..............................................................................11/6 Mechanical load ..........................................................................................2/9 Metal factor examples ..................................................................13/15, 13/16 Metal surcharges .....................................................................................13/15 Mobile Media .............................................................................................13/4 Modernization & Optimization Services.....................................................13/9 Modified windings – Special versions for non-standard voltage or speed.....................................................................................................3/10 More information ..........................................................................................2/9 Motor connection .........................................................................................2/9 Motor connection – Marine motors ............................................................12/5 Motor protection...........................................................................................2/9 Motor protection – Marine motors ..............................................................12/7 Motors 1LH1 ................................................................................................1/2 Motors 1LH1/1MH1 for converter-fed operation ..........................................6/2 • Line voltage 400 V, 50 Hz ........................................................................6/2 - High Efficiency......................................................................................6/2 - Premium Efficiency ...............................................................................6/4 • Line voltage 460 V, 60 Hz ......................................................................6/14 - High Efficiency....................................................................................6/14 - Premium Efficiency .............................................................................6/16 • Line voltage 500 V, 50 Hz ........................................................................6/6 - High Efficiency......................................................................................6/6 - Premium Efficiency ...............................................................................6/8 • Line voltage 575 V, 60 Hz ......................................................................6/18 - High Efficiency....................................................................................6/18 - Premium Efficiency .............................................................................6/20 • Line voltage 690 V, 50 Hz ......................................................................6/10 - High Efficiency....................................................................................6/10 - Premium Efficiency .............................................................................6/12 Motors 1LH1/1MH1 for mains-fed operation .............................................6/22 • Line voltage 400 V, 50 Hz ......................................................................6/22 - High Efficiency....................................................................................6/22 - Premium Efficiency .............................................................................6/24 • Line voltage 460 V, 60 Hz ......................................................................6/30 - High Efficiency....................................................................................6/30 - Premium Efficiency .............................................................................6/32 • Line voltage 690 V, 50 Hz ......................................................................6/26 - High Efficiency....................................................................................6/26 - Premium Efficiency .............................................................................6/28 Motors 1LL1 .................................................................................................1/2 Motors 1LL1 for converter-fed operation .....................................................8/2 • Line Voltage 400 V, 50 Hz, High Efficiency..............................................8/2 • Line Voltage 460 V, 60 Hz, High Efficiency..............................................8/8 • Line Voltage 500 V, 50 Hz, High Efficiency..............................................8/4 • Line Voltage 575 V, 60 Hz, High Efficiency............................................8/10 • Line Voltage 690 V, 50 Hz, High Efficiency..............................................8/6 Motors 1LM1 ................................................................................................1/2 Motors 1LM1/1MM1 for converter-fed operation .........................................4/2 • Line voltage 400 V, 50 Hz ........................................................................4/2 - High Efficiency......................................................................................4/2 - Premium Efficiency ...............................................................................4/4 • Line voltage 460 V, 60 Hz ......................................................................4/14 - High Efficiency....................................................................................4/14 - Premium Efficiency .............................................................................4/16 • Line voltage 500 V, 50 Hz ........................................................................4/6 - High Efficiency......................................................................................4/6 - Premium Efficiency ...............................................................................4/8 • Line voltage 575 V, 60 Hz ......................................................................4/18 - High Efficiency....................................................................................4/18 - Premium Efficiency .............................................................................4/20 • Line voltage 690 V, 50 Hz ......................................................................4/10 - High Efficiency....................................................................................4/10 - Premium Efficiency .............................................................................4/12 Motors 1LN1 ................................................................................................ 1/3 Motors 1LN1/1MN1 for converter-fed operation.......................................... 7/2 • Line Voltage 400 V, 50 Hz, High Efficiency ............................................. 7/2 • Line Voltage 460 V, 60 Hz, High Efficiency ............................................. 7/8 • Line Voltage 500 V, 50 Hz, High Efficiency ............................................. 7/4 • Line Voltage 575 V, 60 Hz, High Efficiency ........................................... 7/10 • Line Voltage 690 V, 50 Hz, High Efficiency ............................................. 7/6 Motors 1LP1 ................................................................................................ 1/2 Motors 1LP1 for converter-fed operation..................................................... 9/2 • Line voltage 400 V, 50 Hz........................................................................ 9/2 - High Efficiency – low noise .................................................................. 9/2 - High Efficiency – increased output ...................................................... 9/4 • Line voltage 460 V, 60 Hz...................................................................... 9/14 - High Efficiency – low noise ................................................................ 9/14 - High Efficiency – increased output .................................................... 9/16 • Line voltage 500 V, 50 Hz........................................................................ 9/6 - High Efficiency – low noise .................................................................. 9/6 - High Efficiency – increased output ...................................................... 9/8 • Line voltage 575 V, 60 Hz...................................................................... 9/18 - High Efficiency – low noise ................................................................ 9/18 - High Efficiency – increased output .................................................... 9/20 • Line voltage 690 V, 50 Hz...................................................................... 9/10 - High Efficiency – low noise ................................................................ 9/10 - High Efficiency – increased output .................................................... 9/12 Motors 1LQ1 ................................................................................................ 1/2 Motors 1LQ1/1MQ1 ................................................................................... 5/32 Motors 1LQ1/1MQ1 for converter-fed operation ......................................... 5/2 • Line voltage 400 V, 50 Hz........................................................................ 5/2 - High Efficiency – low noise .................................................................. 5/2 - High Efficiency – increased output ...................................................... 5/4 - Premium Efficiency............................................................................... 5/6 • Line voltage 460 V, 60 Hz...................................................................... 5/20 - High Efficiency – low noise ................................................................ 5/20 - High Efficiency – increased output .................................................... 5/22 - Premium Efficiency............................................................................. 5/24 • Line voltage 500 V, 50 Hz........................................................................ 5/8 - High Efficiency – low noise .................................................................. 5/8 - High Efficiency – increased output .................................................... 5/10 - Premium Efficiency............................................................................. 5/12 • Line voltage 575 V, 60 Hz...................................................................... 5/26 - High Efficiency – low noise ................................................................ 5/26 - High Efficiency – increased output .................................................... 5/28 - Premium Efficiency............................................................................. 5/30 • Line voltage 690 V, 50 Hz...................................................................... 5/14 - High Efficiency – low noise ................................................................ 5/14 - High Efficiency – increased output .................................................... 5/16 - Premium Efficiency............................................................................. 5/18 Motors specially designed for converter-fed operation .............................. 2/6 Motors specially designed for mains-fed operation (1LH1) ........................ 2/9 N Noise ........................................................................................................... 2/7 Noise emission for operation on SINAMICS converter.............................. 3/10 O Offer and ordering processes for option package – Water & waste water................................................................................ 12/11 Online Services ......................................................................................... 13/3 Online Support .......................................................................................... 13/6 Options ...................................................................................................... 11/7 Options Explosion-proof motors .............................................................. 11/20 Options for special environments – Chemical industry ........................... 12/10 Options Motors without explosion protection ............................................ 11/7 Ordering examples – Marine motors ......................................................... 12/8 Ordering notes – Marine motors................................................................ 12/7 Orientation ................................................................................................... 1/2 Overload torques, maximum ....................................................................... 2/8 Overview – Technical Information................................................................ 2/2 Overview of product lines............................................................................ 1/3 Overview of SIMOTICS FD 1MM, 1MH, 1MQ, 1MN explosion-proof motors........................................................................................................ 10/3 Siemens D 81.8 · 04/2014 13/11 13 © Siemens AG 2014 Appendix Indexes Subject index P Paint finish – Marine motors.......................................................................12/7 Partners at Industry Automation and Drive Technologies .........................13/2 Percentage method .................................................................................13/15 Performance features of the SIMOTICS FD series ......................................1/3 Plant Maintenance & Condition Monitoring ...............................................13/9 Prices .......................................................................................................13/18 Product range for the water & waste water option packages – Water & waste water ................................................................................12/11 Product Selection using the Interactive Catalog CA 01 of Industry ..........13/3 R Rated motor speeds ....................................................................................3/8 Rated motor voltages according to line voltage and infeed........................3/6 Rated speeds ..............................................................................................3/8 Rated voltage...............................................................................................2/6 Rating plate..................................................................................................2/6 Rating plate and acceptance test certificate – Marine motors..................12/7 Recommended SINAMICS converters ........................................................3/8 Recommended special versions – Marine motors ....................................12/7 Reduced base-load currents IL of the SINAMICS converters .....................3/9 Reducing bearing currents ..........................................................................2/7 Regreasing ................................................................................................2/14 Regreasing intervals ..................................................................................2/14 Regulated infeed .........................................................................................3/4 Related catalogs.......................................................................................... U2 Repair Services..........................................................................................13/7 13 S Self-ventilated motors – enclosed version ...................................................4/1 Self-ventilated motors – open version..........................................................8/1 Separately driven fan position ...................................................................11/5 Service Contracts ......................................................................................13/9 Severe Duty – SIMOTICS SD .......................................................................1/2 Shaft seal and degree of protection ..........................................................2/13 Siemens Industry Automation and Drive Technologies in the WWW.........13/3 Siemens Integrated Drive Systems............................................................3/14 SIMOTICS – Low-voltage motors for mains-fed and converter-fed operation......................................................................................................1/2 SIMOTICS FD...............................................................................................3/2 SIMOTICS FD motor on alternative converters............................................3/7 SIMOTICS FD motor on SINAMICS converter .............................................3/7 SIMOTICS FD motor series..........................................................................2/2 Simple motor selection – detail level 1 ........................................................3/6 SINAMICS converters, recommended ........................................................3/8 Single-joint couplings ................................................................................3/15 SIPLUS CMS condition monitoring systems for the continuous condition monitoring of motors ..................................................................3/13 Site altitude ..................................................................................................3/2 Social Media ..............................................................................................13/4 Spare Parts ................................................................................................13/7 Special technology – Explosion-proof motors ...........................................10/7 Special versions................................................................................3/10, 11/1 Specifications ..............................................................................................2/5 Specifications of the individual classification societies with order codes for ordering SIMOTICS FD motors in marine design.............12/5 Standards ....................................................................................................2/5 Start-up procedure for three-phase motors with squirrel-cage rotor .........2/11 Start-up time for direct-on-line starting, calculation...................................2/10 Structure of catalog motor selection tables .................................................3/2 Structure of the article numbers for motors .................................................1/6 Structure of the metal factor .........................................................13/15, 13/16 Subject index ...........................................................................................13/10 Surcharge calculation ...................................................................13/15, 13/16 System Components....................................................................................3/1 13/12 Siemens D 81.8 · 04/2014 T Technical Consulting & Engineering Support............................................ 13/8 Technical content of the option package – Water & waste water............ 12/12 Technical Information .................................................................................. 2/1 Technical Information – Explosion-proof motors ....................................... 10/2 Technical specifications ............................................................ 2/5, 10/4, 12/5 Technical Support...................................................................................... 13/6 Temperature class and coolant temperature – Marine motors.................. 12/6 The basic design of the SIMOTICS FD motor series................................... 2/4 The SIMOTICS family of motors .................................................................. 1/2 Thermal torque limits (continuous duty) ...................................................... 2/8 Three-month average price ..................................................................... 13/16 Torque characteristic ................................................................................... 2/9 Totally Integrated Automation (TIA) ................................................................ 4 Totally Integrated Power (TIP) ........................................................................ 6 Training ...................................................................................................... 13/8 Transnorm – SIMOTICS TN.......................................................................... 1/2 Two-joint couplings.................................................................................... 3/15 Type of protection Ex nA for use in Zone 2 – Explosion-proof motors....... 10/4 Type of protection Ex tc for use in Zone 22 – Explosion-proof motors ...... 10/4 Types of construction ................................................................................ 11/3 Types of protection – Explosion-proof motors ........................................... 10/2 U Unregulated infeed...................................................................................... 3/3 V Values of the metal factor ........................................................................ 13/17 Versions of the SIMOTICS FD motor series ................................................. 2/2 VIK version ..................................................................................... 10/7, 12/10 Voltage supply via the converter ................................................................. 3/3 Voltages ..................................................................................................... 11/2 W Water & waste water................................................................................ 12/11 Water cooling...................................................................................... 2/9, 12/5 Water cooling (1LH1 and 1LN1 motors).................................................... 3/11 Water-cooled motors with air-to-water heat exchanger............................... 7/1 Water-cooled motors with water-jacket cooling........................................... 6/1 Weight method ............................................................................. 13/15, 13/16 Winding and motor protection – Marine motors ........................................ 12/7 © Siemens AG 2014 Appendix Indexes Index of article numbers 1LH1 1LH1202-3A… ........................................................................6/22, 6/26, 6/30 1LH1202-3B… ........................................................................6/22, 6/26, 6/30 1LH1203-3A… ........................................................................6/24, 6/28, 6/32 1LH1203-3B… ........................................................................6/24, 6/28, 6/32 1LH1212-3A… ..........................................................6/2, 6/6, 6/10, 6/14, 6/18 1LH1212-3B... ...........................................................6/2, 6/6, 6/10, 6/14, 6/18 1LH1213-3A… ..........................................................6/4, 6/8, 6/12, 6/16, 6/20 1LH1213-3B… ..........................................................6/4, 6/8, 6/12, 6/16, 6/20 1LH1222-3A… ..........................................................6/2, 6/6, 6/10, 6/14, 6/18 1LH1222-3B… ..........................................................6/2, 6/6, 6/10, 6/14, 6/18 1LH1223-3A… ..........................................................6/4, 6/8, 6/12, 6/16, 6/20 1LH1223-3B… ..........................................................6/4, 6/8, 6/12, 6/16, 6/20 1MH1 1MH1202-3A… 1MH1202-3B… 1MH1203-3A… 1MH1203-3B… 1MH1212-3A… 1MH1212-3B... 1MH1213-3A… 1MH1213-3B… 1MH1222-3A… 1MH1222-3B… 1MH1223-3A… 1MH1223-3B… ....................................................................... 6/22, 6/26, 6/30 ....................................................................... 6/22, 6/26, 6/30 ....................................................................... 6/24, 6/28, 6/32 ....................................................................... 6/24, 6/28, 6/32 ......................................................... 6/2, 6/6, 6/10, 6/14, 6/18 ......................................................... 6/2, 6/6, 6/10, 6/14, 6/18 ......................................................... 6/4, 6/8, 6/12, 6/16, 6/20 ......................................................... 6/4, 6/8, 6/12, 6/16, 6/20 ......................................................... 6/2, 6/6, 6/10, 6/14, 6/18 ......................................................... 6/2, 6/6, 6/10, 6/14, 6/18 ......................................................... 6/4, 6/8, 6/12, 6/16, 6/20 ......................................................... 6/4, 6/8, 6/12, 6/16, 6/20 1LL1 1LL1212-3A… 1LL1212-3B… 1LL1222-3A… 1LL1222-3B… ...............................................................8/2, 8/4, 8/6, 8/8, 8/10 ...............................................................8/2, 8/4, 8/6, 8/8, 8/10 ...............................................................8/2, 8/4, 8/6, 8/8, 8/10 ...............................................................8/2, 8/4, 8/6, 8/8, 8/10 1ML1 1ML1212-3A… 1ML1212-3B… 1ML1222-3A… 1ML1222-3B… ............................................................. 8/2, 8/4, 8/6, 8/8, 8/10 ............................................................. 8/2, 8/4, 8/6, 8/8, 8/10 ............................................................. 8/2, 8/4, 8/6, 8/8, 8/10 ............................................................. 8/2, 8/4, 8/6, 8/8, 8/10 1LM1 1LM1212-3A… 1LM1212-3B… 1LM1213-3A… 1LM1213-3B… 1LM1222-3A… 1LM1222-3B… 1LM1223-3A… 1LM1223-3B… ..........................................................4/2, 4/6, 4/10, 4/14, 4/18 ..........................................................4/2, 4/6, 4/10, 4/14, 4/18 ..........................................................4/4, 4/8, 4/12, 4/16, 4/20 ..........................................................4/4, 4/8, 4/12, 4/16, 4/20 ..........................................................4/2, 4/6, 4/10, 4/14, 4/18 ..........................................................4/2, 4/6, 4/10, 4/14, 4/18 ..........................................................4/4, 4/8, 4/12, 4/16, 4/20 ..........................................................4/4, 4/8, 4/12, 4/16, 4/20 1MM1 1MM1212-3A… 1MM1212-3B… 1MM1213-3A… 1MM1213-3B… 1MM1222-3A… 1MM1222-3B… 1MM1223-3A… 1MM1223-3B… ........................................................ 4/2, 4/6, 4/10, 4/14, 4/18 ........................................................ 4/2, 4/6, 4/10, 4/14, 4/18 ........................................................ 4/4, 4/8, 4/12, 4/16, 4/20 ........................................................ 4/4, 4/8, 4/12, 4/16, 4/20 ........................................................ 4/2, 4/6, 4/10, 4/14, 4/18 ........................................................ 4/2, 4/6, 4/10, 4/14, 4/18 ........................................................ 4/4, 4/8, 4/12, 4/16, 4/20 ........................................................ 4/4, 4/8, 4/12, 4/16, 4/20 1LN1 1LN1212-3A… 1LN1212-3B… 1LN1222-3A… 1LN1222-3B… ..............................................................7/2, 7/4, 7/6, 7/8, 7/10 ..............................................................7/2, 7/4, 7/6, 7/8, 7/10 ..............................................................7/2, 7/4, 7/6, 7/8, 7/10 ..............................................................7/2, 7/4, 7/6, 7/8, 7/10 1LP1 1LP1212-3A… 1LP1212-3B… 1LP1222-3A… 1LP1222-3B… 1LP1312-3A… 1LP1312-3B… 1LP1322-3A… 1LP1322-3B… ...........................................................9/2, 9/6, 9/10, 9/14, 9/18 ...........................................................9/2, 9/6, 9/10, 9/14, 9/18 ...........................................................9/2, 9/6, 9/10, 9/14, 9/18 ...........................................................9/2, 9/6, 9/10, 9/14, 9/18 ...........................................................9/4, 9/8, 9/12, 9/16, 9/20 ...........................................................9/4, 9/8, 9/12, 9/16, 9/20 ...........................................................9/4, 9/8, 9/12, 9/16, 9/20 ...........................................................9/4, 9/8, 9/12, 9/16, 9/20 1MQ1 1MQ1212-3A… 1MQ1212-3B… 1MQ1213-3A… 1MQ1213-3B… 1MQ1222-3A… 1MQ1222-3B… 1MQ1223-3A… 1MQ1223-3B… 1MQ1312-3A… 1MQ1312-3B… 1MQ1322-3A… 1MQ1322-3B… ......................................................... 5/2, 5/8, 5/14, 5/20, 5/26 ......................................................... 5/2, 5/8, 5/14, 5/20, 5/26 ....................................................... 5/6, 5/12, 5/18, 5/24, 5/30 ....................................................... 5/6, 5/12, 5/18, 5/24, 5/30 ......................................................... 5/2, 5/8, 5/14, 5/20, 5/26 ......................................................... 5/2, 5/8, 5/14, 5/20, 5/26 ....................................................... 5/6, 5/12, 5/18, 5/24, 5/30 ....................................................... 5/6, 5/12, 5/18, 5/24, 5/30 ....................................................... 5/4, 5/10, 5/16, 5/22, 5/28 ....................................................... 5/4, 5/10, 5/16, 5/22, 5/28 ....................................................... 5/4, 5/10, 5/16, 5/22, 5/28 ....................................................... 5/4, 5/10, 5/16, 5/22, 5/28 1LQ1 1LQ1212-3A… 1LQ1212-3B… 1LQ1213-3A… 1LQ1213-3B… 1LQ1222-3A… 1LQ1222-3B… 1LQ1223-3A… 1LQ1223-3B… 1LQ1312-3A… 1LQ1312-3B… 1LQ1322-3A… 1LQ1322-3B… ..........................................................5/2, 5/8, 5/14, 5/20, 5/26 ..........................................................5/2, 5/8, 5/14, 5/20, 5/26 ........................................................5/6, 5/12, 5/18, 5/24, 5/30 ........................................................5/6, 5/12, 5/18, 5/24, 5/30 ..........................................................5/2, 5/8, 5/14, 5/20, 5/26 ..........................................................5/2, 5/8, 5/14, 5/20, 5/26 ........................................................5/6, 5/12, 5/18, 5/24, 5/30 ........................................................5/6, 5/12, 5/18, 5/24, 5/30 ........................................................5/4, 5/10, 5/16, 5/22, 5/28 ........................................................5/4, 5/10, 5/16, 5/22, 5/28 ........................................................5/4, 5/10, 5/16, 5/22, 5/28 ........................................................5/4, 5/10, 5/16, 5/22, 5/28 6SL3370-7PE.. 6SL3370-1PE36-6AA0 ......................................................... 4/3, 4/5, 4/15, 8/3 6SL3710-1GE.. 6SL3710-1GE32-6AA3 ............................................................................... 4/7 6SL3710-1GE33-1AA3 ........................................ 4/7, 4/9, 5/9, 5/11, 5/13, 6/9 6SL3710-1GE33-8AA3 ................................ 4/3, 4/5, 4/7, 4/15, 5/3, 5/9, 5/11, ................................................................................ 5/21, 6/7, 6/9, 7/5, 8/5, 9/7 6SL3710-1GE35-0AA3 ......................... 4/3, 4/5, 4/7, 4/9, 4/15, 4/17, 5/3, 5/5, ......................................................... 5/7, 5/9, 5/11, 5/13, 5/21, 5/23, 5/25, 6/3, ............................................................... 6/5, 6/7, 6/9, 6/15, 6/17, 7/3, 7/5, 7/9, ......................................................................... 8/3, 8/5, 8/9, 9/3, 9/7, 9/9, 9/15 6SL3710-1GE36-1AA3 ......................... 4/3, 4/5, 4/7, 4/9, 4/15, 4/17, 5/3, 5/5, ......................................................... 5/7, 5/9, 5/11, 5/13, 5/21, 5/23, 5/25, 6/3, ............................................................... 6/5, 6/7, 6/9, 6/15, 6/17, 7/3, 7/5, 7/9, ......................................................... 8/3, 8/5, 8/9, 9/3, 9/5, 9/7, 9/9, 9/15, 9/17 6SL3710-1GE37-5AA3 ......................... 4/3, 4/5, 4/7, 4/9, 4/15, 4/17, 5/3, 5/5, ......................................................... 5/7, 5/9, 5/11, 5/13, 5/21, 5/23, 5/25, 6/3, ............................................................... 6/5, 6/7, 6/9, 6/15, 6/17, 7/3, 7/5, 7/9, ......................................................... 8/3, 8/5, 8/9, 9/3, 9/5, 9/7, 9/9, 9/15, 9/17 6SL3710-1GE38-4AA3 ......................... 4/3, 4/5, 4/9, 4/15, 4/17, 5/3, 5/5, 5/7, ........................................................... 5/11, 5/21, 5/23, 5/25, 6/3, 6/5, 6/7, 6/9, ............................................................... 6/15, 6/17, 7/3, 7/5, 7/9, 8/3, 8/5, 8/9, .............................................................................. 9/3, 9/5, 9/7, 9/9, 9/15, 9/17 6SL3710-1GE41-0AA3 ....................... 4/3, 4/5, 4/15, 4/17, 5/3, 5/5, 5/7, 5/23, ............................................................. 5/25, 6/3, 6/5, 6/7, 6/9, 6/15, 6/17, 7/3, ................................................................... 7/5, 7/9, 8/3, 8/5, 8/9, 9/3, 9/5, 9/7, ................................................................................................... 9/9, 9/15, 9/17 Siemens D 81.8 · 04/2014 13/13 13 © Siemens AG 2014 Appendix Indexes Index of article numbers 6SL3710-1GF.. 6SL3710-1GF32-2AA3 .......................................................................3/9, 4/21 6SL3710-1GF32-6AA3 .....................................................................4/19, 4/21 6SL3710-1GF33-3AA3 ........................4/19, 5/27, 5/29, 5/31, 6/19, 6/21, 8/11 6SL3710-1GF34-1AA3 ................................4/19, 4/21, 5/27, 5/29, 5/31, 6/19, ........................................................................................7/11, 8/11, 9/19, 9/21 6SL3710-1GF34-7AA3 ................................4/19, 4/21, 5/27, 5/29, 5/31, 6/19, ...............................................................................6/21, 7/11, 8/11, 9/19, 9/21 6SL3710-1GF35-8AA3 ................................4/19, 4/21, 5/27, 5/29, 5/31, 6/19, ...............................................................................6/21, 7/11, 8/11, 9/19, 9/21 6SL3710-1GF37-4AA3 ................................4/19, 4/21, 5/27, 5/29, 5/31, 6/19, ...............................................................................6/21, 7/11, 8/11, 9/19, 9/21 6SL3710-1GF38-1AA3 .................................6/19, 6/21, 7/11, 8/11, 9/19, 9/21 6SL3710-1GH.. 6SL3710-1GH31-8AA3 ....................................................................4/11, 4/13 6SL3710-1GH32-..A3 ................................................................................6/13 6SL3710-1GH32-2AA3 .........................4/11, 4/13, 5/15, 5/17, 5/19, 6/11, 8/7 6SL3710-1GH32-6AA3 .........4/11, 4/13, 5/15, 5/17, 6/13, 7/7, 8/7, 9/11, 9/13 6SL3710-1GH33-..A3 ................................................................................6/13 6SL3710-1GH33-3AA3 ...............................4/11, 4/13, 5/15, 5/17, 5/19, 6/11, ...................................................................................6/13, 7/7, 8/7, 9/11, 9/13 6SL3710-1GH34-..A3 ................................................................................6/13 6SL3710-1GH34-1AA3 ...............................4/11, 4/13, 5/15, 5/17, 5/19, 6/11, ...................................................................................6/13, 7/7, 8/7, 9/11, 9/13 6SL3710-1GH34-7AA3 ........................................4/11, 5/15, 5/17, 5/19, 6/11, ...................................................................................6/13, 7/7, 8/7, 9/11, 9/13 6SL3710-1GH35-8AA3 .........4/11, 4/13, 5/17, 5/19, 6/11, 7/7, 8/7, 9/11, 9/13 6SL3710-1GH37-4AA3 ....................................6/11, 6/13, 7/7, 8/7, 9/11, 9/13 6SL3710-1GH38-1AA3 .............................................................................9/13 6SL3710-1PE33-7AA0 ................................................................4/3, 4/5, 4/15 6SL3710-1PE34-6AA0 .......................................................4/3, 4/15, 4/17, 8/3 6SL3710-1PE35-8AA0 ................................................4/3, 4/5, 4/15, 4/17, 8/3 6SL3710-1PE37-4AA0 ................................................4/3, 4/5, 4/15, 4/17, 8/3 6SL3710-2GE.. 6SL3710-2GE41-1AA3 ..........................6/3, 6/5, 6/15, 6/17, 7/3, 7/5, 7/9, 8/3, ................................................................8/5, 8/9, 9/3, 9/5, 9/7, 9/9, 9/15, 9/17 6SL3710-2GE41-4AA3 ...................................6/3, 6/5, 6/17, 7/3, 7/9, 8/3, 8/9, .....................................................................................9/3, 9/5, 9/9, 9/15, 9/17 6SL3710-2GE41-6AA3 ................................................................8/3, 9/5, 9/17 6SL3710-2GF.. 6SL3710-2GF38-6AA3 ............................................................8/11, 9/19, 9/21 6SL3710-2GF41-1AA3 ...................................................7/11, 8/11, 9/19, 9/21 13 13/14 Siemens D 81.8 · 04/2014 6SL3710-7LE.. 6SL3710-7LE33-1AA3 ................................. 4/3, 4/5, 4/15, 5/3, 4/17, 5/5, 5/7, ............................................................................ 5/21, 5/23, 5/25, 6/3, 6/5, 8/3 6SL3710-7LE35-0AA3 ........................ 4/3, 4/5, 4/15, 4/17, 5/3, 5/5, 5/7, 5/21, ........................................................... 5/23, 5/25, 6/3, 6/15, 6/17, 7/3, 7/9, 8/3, ..................................................................................... 8/9, 9/3, 9/5, 9/15, 9/17 6SL3710-7LE36-1AA3 ........................ 4/3, 4/5, 4/15, 4/17, 5/3, 5/5, 5/7, 5/21, ........................................................... 5/23, 5/25, 6/3, 6/5, 6/15, 6/17, 7/3, 7/9, .............................................................................. 8/3, 8/9, 9/3, 9/5, 9/15, 9/17 6SL3710-7LE37-5AA3 ........................ 4/3, 4/5, 4/15, 4/17, 5/3, 5/5, 5/7, 5/21, ........................................................... 5/23, 5/25, 6/3, 6/5, 6/15, 6/17, 7/3, 7/9, .............................................................................. 8/3, 8/9, 9/3, 9/5, 9/15, 9/17 6SL3710-7LE38-4AA3 ........................ 4/3, 4/5, 4/15, 4/17, 5/3, 5/5, 5/7, 5/23, ............................................................... 5/25, 6/3, 6/5, 6/15, 7/3, 7/9, 8/3, 8/9, ............................................................................................ 9/3, 9/5, 9/15, 9/17 6SL3710-7LE41-0AA3 ................................. 6/3, 6/5, 6/15, 6/17, 7/3, 7/9, 8/3, ..................................................................................... 8/9, 9/3, 9/5, 9/15, 9/17 6SL3710-7LE41-2AA3 .......................................... 6/3, 6/5, 6/17, 7/3, 7/9, 8/3, ..................................................................................... 8/9, 9/3, 9/5, 9/15, 9/17 6SL3710-7LG.. 6SL3710-7LG31-5AA3 ............................................................................. 4/11 6SL3710-7LG31-8AA3 ......................................... 4/11, 4/13, 4/21, 5/15, 5/17 6SL3710-7LG32-2AA3 .......................................... 4/7, 4/11, 4/13, 4/19, 5/15, ................................................................................. 5/19, 6/11, 6/13, 6/13, 8/7 6SL3710-7LG32-6AA3 ............................ 4/7, 4/9, 4/11, 4/13, 4/19, 5/9, 5/13, ..................................................................... 5/15, 5/17, 5/19, 5/29, 6/11, 6/13, ............................................................................................ 7/7, 8/7, 9/11, 9/13 6SL3710-7LG33-3AA3 ................... 4/7, 4/9, 4/11, 4/13, 4/19, 4/21, 5/9, 5/11, ..................................................... 5/13, 5/15, 5/17, 5/19, 5/27, 5/29, 5/31, 6/7, ......................................................... 6/9, 6/11, 6/13, 6/19, 6/21, 7/5, 7/7, 7/11, .......................................................... 8/5, 8/7, 8/11, 9/7, 9/11, 9/13, 9/19, 9/21 6SL3710-7LG34-1AA3 ................... 4/7, 4/9, 4/11, 4/13, 4/19, 4/21, 5/9, 5/11, ..................................................... 5/13, 5/15, 5/17, 5/19, 5/27, 5/29, 5/31, 6/7, ......................................................... 6/9, 6/11, 6/13, 6/19, 6/21, 7/5, 7/7, 7/11, ................................................... 8/5, 8/7, 8/11, 9/7, 9/9, 9/11, 9/13, 9/19, 9/21 6SL3710-7LG34-7AA3 ................. 4/7, 4/11, 4/13, 4/19, 4/21, 5/9, 5/11, 5/13, ....................................................... 5/15, 5/17, 5/19, 5/27, 5/29, 5/31, 6/7, 6/9, ......................................................... 6/11, 6/13, 6/19, 6/21, 7/5, 7/7, 7/11, 8/5, .......................................................... 8/7, 8/11, 9/7, 9/9, 9/11, 9/13, 9/19, 9/21 6SL3710-7LG35-8AA3 ................... 4/7, 4/9, 4/19, 4/21, 5/9, 5/11, 5/13, 5/17, ....................................................... 5/27, 5/29, 5/31, 6/7, 6/9, 6/11, 6/19, 6/21, ............................................................... 7/5, 7/7, 7/11, 8/5, 8/7, 8/11, 9/7, 9/9, ........................................................................................ 9/11, 9/13, 9/19, 9/21 6SL3710-7LG37-4AA3 ................... 4/7, 4/9, 4/19, 4/21, 5/9, 5/11, 5/13, 5/29, .................................................... 5/31, 6/7, 6/9, 6/19, 6/21, 7/5, 7/7, 7/11, 8/5, .......................................................... 8/7, 8/11, 9/7, 9/9, 9/11, 9/13, 9/19, 9/21 6SL3710-7LG38-1AA3 ..................................... 6/7, 6/9, 6/19, 6/21, 7/5, 7/11, ............................................................................ 8/5, 8/11, 9/7, 9/9, 9/19, 9/21 6SL3710-7LG38-8AA3 ........ 6/7, 6/9, 7/5, 7/11, 8/5, 8/11, 9/7, 9/9, 9/19, 9/21 6SL3710-7LG41-0AA3 ...................... 7/5, 7/11, 8/5, 8/11, 9/7, 9/9, 9/19, 9/21 6SL3710-7LG41-3AA3 ............................................................................... 9/9 © Siemens AG 2014 Appendix Metal surcharges ■ Explanation of the raw material/metal surcharges 1) 2) 3) 4) Surcharge calculation To compensate for variations in the price of the raw materials silver, copper, aluminum, lead, gold, dysprosium 2) and/or neodym 2), surcharges are calculated on a daily basis using the so-called metal factor for products containing these raw materials. A surcharge for the respective raw material is calculated as a supplement to the price of a product if the basic official price of the raw material in question is exceeded. The surcharges are calculated in accordance with the following criteria: • Basic official price of the raw material Basic official price from the day prior to receipt of the order or prior to release order (daily price) for 3) - Silver (sales price, processed) - Gold (sales price, processed) Percentage method Use of the percentage method is indicated by the letters A-Z at the respective digit of the metal factor. The surcharge is increased – dependent on the deviation of the daily price compared with the basic official price – using the percentage method in "steps" and consequently offers surcharges that remain constant within the framework of this "step range". A higher percentage rate is charged for each new step. The respective percentage level can be found in the table below. Metal factor examples LEA––––– Basis for % surcharge: List price Silver Basis 150 €, Step 50 €, 0.5 % 4) and for - Copper (lower DEL notation + 1 %) - Aluminum (aluminum in cables) - Lead (lead in cables) • Metal factor of the products Certain products are displayed with a metal factor. The metal factor determines the official price (for those raw materials concerned) as of which the metal surcharges are applied and the calculation method used (weight or percentage method). An exact explanation is given below. Copper Basis 150 €, Step 50 €, 0.1 % No surcharge for aluminum No surcharge for lead No surcharge for gold No surcharge for dysprosium No surcharge for neodym N –A6 –––– Structure of the metal factor Basis for % surcharge: Customer net price The metal factor consists of several digits; the first digit indicates whether the percentage method of calculation refers to the list price or a possible discounted price (customer net price) (L = list price / N = customer net price). No surcharge for silver Copper Basis 150 €, Step 50 €, 0.1 % Aluminum acc. to weight, basic offic. price 225 € The remaining digits indicate the method of calculation used for the respective raw material. If no surcharge is added for a raw material, a "-" is used. No surcharge for lead No surcharge for gold No surcharge for dysprosium 1st digit List or customer net price using the percentage method 2nd digit for silver (AG) 3rd digit for copper (CU) 4th digit for aluminum (AL) No basis necessary 5th digit for lead (PB) No surcharge for silver 6th digit for gold (AU) Copper acc. to weight, basic official price 150 € 7th digit for dysprosium (Dy) 2) No surcharge for aluminum 8th digit for neodym (Nd) 2) No surcharge for lead No surcharge for neodym – –3 – – – – – No surcharge for gold Weight method The weight method uses the basic official price, the daily price and the raw material weight. In order to calculate the surcharge, the basic official price must be subtracted from the daily price. The difference is then multiplied by the raw material weight. No surcharge for dysprosium No surcharge for neodym 13 The basic official price can be found in the table below using the number (1 to 9) of the respective digit of the metal factor. The raw material weight can be found in the respective product descriptions. 1) 2) 3) 4) Refer to the separate explanation on the next page regarding the raw materials dysprosium and neodym (= rare earths). For a different method of calculation, refer to the separate explanation for these raw materials on the next page. Source: Umicore, Hanau (www.metalsmanagement.umicore.com). Source: German Trade Association for Cables and Conductors (www.kabelverband.org). Siemens D 81.8 · 04/2014 13/15 © Siemens AG 2014 Appendix Metal surcharges ■ Explanation of the raw material/metal surcharges for dysprosium and neodym (rare earths)1) 2) Surcharge calculation To compensate for variations in the price of the raw materials silver 1), copper 1), aluminum 1), lead 1), gold 1), dysprosium and/or neodym, surcharges are calculated on a daily basis using the so-called metal factor for products containing these raw materials. The surcharge for dysprosium and neodym is calculated as a supplement to the price of a product if the basic official price of the raw material in question is exceeded. The surcharge is calculated in accordance with the following criteria: • Basic official price of the raw material 2) Three-month basic average price (see below) in the period before the quarter in which the order was received or the release order took place (= average official price) for - dysprosium (Dy metal, 99 % min. FOB China; USD/kg) - neodym (Nd metal, 99 % min. FOB China; USD/kg) • Metal factor of the products Certain products are displayed with a metal factor. The metal factor indicates (for those raw materials concerned) the basic official price as of which the surcharges for dysprosium and neodym are calculated using the weight method. An exact explanation of the metal factor is given below. Three-month average price The prices of rare earths vary according to the foreign currency, and there is no freely accessible stock exchange listing. This makes it more difficult for all parties involved to monitor changes in price. In order to avoid continuous adjustment of the surcharges, but to still ensure fair, transparent pricing, an average price is calculated over a three-month period using the average monthly foreign exchange rate from USD to EUR (source: European Central Bank). Since not all facts are immediately available at the start of each month, a one-month buffer is allowed before the new average price applies. Structure of the metal factor The metal factor consists of several digits; the first digit is not relevant to the calculation of dysprosium and neodym. The remaining digits indicate the method of calculation used for the respective raw material. If no surcharge is added for a raw material, a "-" is used. 1st digit List or customer net price using the percentage method 2nd digit for silver (AG) 1) 3rd digit for copper (CU) 1) 4th digit for aluminum (AL) 1) 5th digit for lead (PB) 1) 6th digit for gold (AU) 1) 7th digit for dysprosium (Dy) 8th digit for neodym (Nd) Weight method The weight method uses the basic official price, the average price and the raw material weight. In order to calculate the surcharge, the basic official price must be subtracted from the average price. The difference is then multiplied by the raw material weight. The basic official price can be found in the table below using the number (1 to 9) of the respective digit of the metal factor. Your Sales contact can inform you of the raw material weight. Metal factor examples ––––––71 No basis necessary Examples of calculation of the average official price: No surcharge for silver Period for calculation of the average price: Period during which the order/release order is effected and the average price applies: No surcharge for copper Sep 2012 – Nov 2012 Q1 in 2013 (Jan – Mar) Dec 2012 – Feb 2013 Q2 in 2013 (Apr – Jun) Mar 2013 – May 2013 Q3 in 2013 (Jul – Sep) Jun 2013 – Aug 2013 Q4 in 2013 (Oct – Dec) No surcharge for aluminum No surcharge for lead No surcharge for gold Dysprosium acc. to weight, basic official price 300 € Neodym acc. to weight, basic official price 50 € 13 1) 2) For a different method of calculation, refer to the separate explanation for these raw materials on the previous page. Source: Asian Metal Ltd (www.asianmetal.com) 13/16 Siemens D 81.8 · 04/2014 © Siemens AG 2014 Appendix Metal surcharges ■ Values of the metal factor Percentage method Basic official Step range price in € in € % surcharge 1st step % surcharge 2nd step % surcharge 3rd step % surcharge 4th step Price in € Price in € Price in € Price in € % surcharge per additional step 150.01 – 200.00 200.01 – 250.00 250.01 – 300.00 300.01 – 350.00 A 150 50 0.1 0.2 0.3 0.4 0.1 B 150 50 0.2 0.4 0.6 0.8 0.2 C 150 50 0.3 0.6 0.9 1.2 0.3 D 150 50 0.4 0.8 1.2 1.6 0.4 E 150 50 0.5 1.0 1.5 2.0 0.5 F 150 50 0.6 1.2 1.8 2.4 0.6 G 150 50 1.0 2.0 3.0 4.0 1.0 H 150 50 1.2 2.4 3.6 4.8 1.2 I 150 50 1.6 3.2 4.8 6.4 1.6 J 150 50 1.8 3.6 5.4 7.2 1.8 175.01 – 225.00 225.01 – 275.00 275.01 – 325.00 325.01 – 375.00 O 175 50 0.1 0.2 0.3 0.4 0.1 P 175 50 0.2 0.4 0.6 0.8 0.2 R 175 50 0.5 1.0 1.5 2.0 0.5 225.01 – 275.00 275.01 – 325.00 325.01 – 375.00 375.01 – 425.00 S 225 50 0.2 0.4 0.6 0.8 0.2 U 225 50 1.0 2.0 3.0 4.0 1.0 V 225 50 1.0 1.5 2.0 3.0 1.0 W 225 50 1.0 Y Z 150 400 25 25 1.2 2.5 3.5 4.5 150.01 – 175.00 175.01 – 200.00 200.01 – 225.00 225.01 – 250.00 0.3 0.6 0.9 1.2 400.01 – 425.00 425.01 – 450.00 450.01 – 475.00 475.01 – 500.00 0.1 0.2 0.3 0.4 0.3 0.1 Price basis (1st digit) L Calculation based on the list price N Calculation based on the customer net price (discounted list price) Weight method Basic official price in € 1 50 2 100 3 150 4 175 5 200 6 225 7 300 8 400 9 555 Calculation based on raw material weight 13 Miscellaneous - No metal surcharge Siemens D 81.8 · 04/2014 13/17 © Siemens AG 2014 Appendix Conditions of sale and delivery ■ 1. General Provisions By using this catalog you can acquire hardware and software products described therein from Siemens AG subject to the following Terms and Conditions of Sale and Delivery (hereinafter referred to as "T&C"). Please note that the scope, the quality and the conditions for supplies and services, including software products, by any Siemens entity having a registered office outside Germany, shall be subject exclusively to the General Terms and Conditions of the respective Siemens entity. The following T&C apply exclusively for orders placed with Siemens Aktiengesellschaft, Germany. 1.1 For customers with a seat or registered office in Germany For customers with a seat or registered office in Germany, the following applies subordinate to the T&C: • the "General Terms of Payment" 1) and, • for software products, the "General License Conditions for Software Products for Automation and Drives for Customers with a Seat or Registered Office in Germany" 1) and, • for other supplies and services, the "General Conditions for the Supply of Products and Services of the Electrical and Electronics Industry" 1). 1.2 For customers with a seat or registered office outside Germany For customers with a seat or registered office outside Germany, the following applies subordinate to the T&C: • the "General Terms of Payment" 1) and, • for software products, the "General License Conditions for Software Products for Automation and Drives for Customers with a Seat or Registered Office outside of Germany" 1) and • for other supplies and/or services, the "General Conditions for Supplies of Siemens Industry for Customers with a Seat or Registered Office outside of Germany" 1). ■ 2. Prices 13 The prices are in € (Euro) ex point of delivery, exclusive of packaging. The sales tax (value added tax) is not included in the prices. It shall be charged separately at the respective rate according to the applicable statutory legal regulations. Prices are subject to change without prior notice. We will charge the prices valid at the time of delivery. To compensate for variations in the price of raw materials (e.g. silver, copper, aluminum, lead, gold, dysprosium and neodym), surcharges are calculated on a daily basis using the so-called metal factor for products containing these raw materials. A surcharge for the respective raw material is calculated as a supplement to the price of a product if the basic official price of the raw material in question is exceeded. The metal factor of a product indicates the basic official price (for those raw materials concerned) as of which the surcharges on the price of the product are applied, and with what method of calculation. You will find a detailed explanation of the metal factor on the page headed "Metal surcharges". To calculate the surcharge (except in the cases of dysprosium and neodym), the official price from the day prior to that on which the order was received or the release order was effected is used. To calculate the surcharge applicable to dysprosium and neodym ("rare earths"), the corresponding three-month basic average price in the quarter prior to that in which the order was received or the release order was effected is used with a onemonth buffer (details on the calculation can be found in the explanation of the metal factor). 13/18 Siemens D 81.8 · 04/2014 ■ 3. Additional Terms and Conditions The dimensions are in mm. In Germany, according to the German law on units in measuring technology, data in inches apply only to devices for export. Illustrations are not binding. Insofar as there are no remarks on the individual pages of this catalog – especially with regard to data, dimensions and weights given – these are subject to change without prior notice. ■ 4. Export regulations We shall not be obligated to fulfill any agreement if such fulfillment is prevented by any impediments arising out of national or international foreign trade or customs requirements or any embargoes and/or other sanctions. Export of goods listed in this catalog may be subject to licensing requirements. We will indicate in the delivery details whether licenses are required under German, European and US export lists. Goods labeled with "AL" not equal to "N" are subject to European or German export authorization when being exported out of the EU. Goods labeled with "ECCN" not equal to "N" are subject to US re-export authorization. The export indications can be viewed in advance in the description of the respective goods on the Industry Mall, our online catalog system. Only the export labels "AL" and "ECCN" indicated on order confirmations, delivery notes and invoices are authoritative. Even without a label, or with label "AL:N" or "ECCN:N", authorization may be required i.a. due to the final disposition and intended use of goods. If you transfer goods (hardware and/or software and/or technology as well as corresponding documentation, regardless of the mode of provision) delivered by us or works and services (including all kinds of technical support) performed by us to a third party worldwide, you must comply with all applicable national and international (re-)export control regulations. If required for the purpose of conducting export control checks, you (upon request by us) shall promptly provide us with all information pertaining to the particular end customer, final disposition and intended use of goods delivered by us respectively works and services provided by us, as well as to any export control restrictions existing in this relation. The products listed in this catalog may be subject to European/German and/or US export regulations. Any export requiring approval is therefore subject to authorization by the relevant authorities. Errors excepted and subject to change without prior notice. 1) The text of the Terms and Conditions of Siemens AGcan be downloaded at www.siemens.com/automation/salesmaterial-as/catalog/en/ terms_of_trade_en.pdf © Siemens AG 2014 Catalogs Industry Automation, Drive Technologies and Low-Voltage Power Distribution Further information can be obtained from our branch offices listed at www.siemens.com/automation/partner System Solutions for Industry Interactive Catalog on DVD Catalog Products for Automation and Drives, Low-Voltage Power CA 01 Distribution and Electrical Installation Technology Building Control GAMMA Building Control Drive Systems SINAMICS G130 Drive Converter Chassis Units SINAMICS G150 Drive Converter Cabinet Units SINAMICS GM150, SINAMICS SM150 Medium-Voltage Converters SINAMICS PERFECT HARMONY GH180 Medium-Voltage Air-Cooled Drives Germany Edition SINAMICS G180 Converters – Compact Units, Cabinet Systems, Cabinet Units Air-Cooled and Liquid-Cooled SINAMICS S120 Chassis Format Units and Cabinet Modules SINAMICS S150 Converter Cabinet Units SINAMICS DCM Converter Units SINAMICS DCM Cabinet SINAMICS and Motors for Single-Axis Drives Three-Phase Induction Motors SIMOTICS HV, SIMOTICS TN • Series H-compact • Series H-compact PLUS Asynchronous Motors Standardline Synchronous Motors with Permanent-Magnet Technology, HT-direct DC Motors SIMOREG DC MASTER 6RA70 Digital Chassis Converters SIMOREG K 6RA22 Analog Chassis Converters Digital: SIMOREG DC MASTER 6RM70 Digital Converter Cabinet Units SIMOVERT PM Modular Converter Systems SIEMOSYN Motors MICROMASTER 420/430/440 Inverters MICROMASTER 411/COMBIMASTER 411 SIMOVERT MASTERDRIVES Vector Control SIMOVERT MASTERDRIVES Motion Control Synchronous and asynchronous servomotors for SIMOVERT MASTERDRIVES SIMODRIVE 611 universal and POSMO ET G1 D 11 D 12 D 15.1 D 18.1 D 21.3 D 23.1 D 23.2 D 31 D 84.1 D 86.1 D 86.2 DA 12 DA 21.1 DA 21.2 DA 22 DA 45 DA 48 DA 51.2 DA 51.3 DA 65.10 DA 65.11 DA 65.3 DA 65.4 Note: Additional catalogs on SIMODRIVE or SINAMICS drive systems and SIMOTICS motors with SINUMERIK and SIMOTION can be found under Motion Control Low-Voltage Three-Phase-Motors SIMOTICS Low-Voltage Motors MOTOX Geared Motors SIMOGEAR Geared Motors SIMOGEAR Gearboxes with adapter D 81.1 D 87.1 MD 50.1 MD 50.11 Mechanical Driving Machines FLENDER Standard Couplings FLENDER High Performance Couplings FLENDER SIG Standard industrial gear unit FLENDER SIP Standard industrial planetary gear units MD 10.1 MD 10.2 MD 30.1 MD 31.1 Process Instrumentation and Analytics Field Instruments for Process Automation Digital: SIPART Controllers and Software Products for Weighing Technology Digital: Process Analytical Instruments Digital: Process Analytics, Components for the System Integration Digital: These catalogs are only available as a PDF and/or as an e-book. FI 01 MP 31 WT 10 PA 01 PA 11 Low-Voltage Power Distribution and Electrical Installation Technology Catalog SENTRON · SIVACON · ALPHA Protection, Switching, Measuring and Monitoring Devices, Switchboards and Distribution Systems Standards-Compliant Components for Photovoltaic Plants 3WT Air Circuit Breakers up to 4000 A Digital: 3VT Molded Case Circuit Breakers up to 1600 A Digital: SIVACON System Cubicles, System Lighting and System Air-Conditioning Digital: ALPHA Distribution Systems ALPHA FIX Terminal Blocks SIVACON S4 Power Distribution Boards Digital: SIVACON 8PS Busbar Trunking Systems Digital: DELTA Switches and Socket Outlets LV 10 Motion Control SINUMERIK & SIMODRIVE Automation Systems for Machine Tools SINUMERIK & SINAMICS Equipment for Machine Tools SINUMERIK 840D sl Type 1B Equipment for Machine Tools SINUMERIK 808 Equipment for Machine Tools SINUMERIK 828 Equipment for Machine Tools SIMOTION, SINAMICS S120 & SIMOTICS Equipment for Production Machines Drive and Control Components for Cranes LV 11 LV 35 LV 36 LV 50 LV 51 LV 52 LV 56 LV 70 ET D1 NC 60 NC 61 NC 62 NC 81.1 NC 82 PM 21 CR 1 Power Supply Power supply SITOP KT 10.1 Safety Integrated Safety Technology for Factory Automation SI 10 SIMATIC HMI/PC-based Automation Human Machine Interface Systems/ PC-based Automation ST 80/ ST PC SIMATIC Ident Industrial Identification Systems ID 10 SIMATIC Industrial Automation Systems Products for Totally Integrated Automation SIMATIC PCS 7 Process Control System System components SIMATIC PCS 7 Process Control System Technology components Add-ons for the SIMATIC PCS 7 Process Control System ST 70 ST PCS 7 ST PCS 7 T ST PCS 7 AO SIMATIC NET Industrial Communication IK PI SIRIUS Industrial Controls SIRIUS Industrial Controls IC 10 Information and Download Center Digital versions of the catalogs are available on the Internet at: www.siemens.com/industry/infocenter There you’ll find additional catalogs in other languages. Please note the section “Downloading catalogs” on page “Online services” in the appendix of this catalog. © Siemens AG 2014 Industrial Security Siemens provides products and solutions with industrial security functions that support the secure operation of plants, solutions, machines, equipment and/or networks. They are important components in a holistic industrial security concept. With this in mind, Siemens’ products and solutions undergo continuous development. Siemens recommends strongly that you regularly check for product updates. For the secure operation of Siemens products and solutions, it is necessary to take suitable preventive action (e.g. cell protection concept) and integrate each component into a holistic, state-of-the-art industrial security concept. Thirdparty products that may be in use should also be considered. For more information about industrial security, visit www.siemens.com/industrialsecurity To stay informed about product updates as they occur, sign up for a product-specific newsletter. For more information, visit http://support.automation.siemens.com Get more information Siemens Motors: www.siemens.com/motors SIMOTICS FD Flexible Duty Motors: www.siemens.com/simotics-fd Local partners worldwide: www.siemens.com/automation/partner Siemens AG Industry Sector Drive Technologies Division Large Drives Postfach 4743 90025 NÜRNBERG GERMANY www.siemens.com/drives Subject to change without prior notice Article No. E86060-K5581-A181-A2-7600 E.9115.35.LDT / Dispo 18400 KG 0514 0.6 HOF/DPG 268 En Printed in Germany © Siemens AG 2014 Please scan the QR code for more information on Siemens Motors. The information provided in this catalog contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. Availability and technical specifications are subject to change without notice. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners. Token fee: 5.00 €