simotics-fd-catalog-d81-8-en 2014

© Siemens AG 2014
SIMOTICS FD
Flexible Duty Motors
Motors
Catalog
D 81.8
Edition
04/2014
Answers for industry.
© Siemens AG 2014
Related catalogs
SIMOTICS Low-Voltage Motors
Type series 1LE1, 1MB1 and 1PC1
Frame sizes 80 to 315
Power range 0.3 to 250 kW
D 81.1
www.siemens.com/motors/printmaterial
The listed documentation can be ordered here or it is available in
commonly used file formats (PDF, ZIP) for downloading.
E86060-K5581-A111-A6-7600
Energy saving/Energy-saving program SinaSave
SINAMICS Drives
SINAMICS G130
Drive Converter Chassis Units
SINAMICS G150
Drive Converter Cabinet Units
E86060-K5511-A101-A5-7600
D 11
SINAMICS S120
Chassis Format Units and
Cabinet Modules
SINAMICS S150
Converter Cabinet Units
E86060-K5521-A131-A3-7600
D 21.3
FLENDER couplings
Standard Couplings
Interactive Catalog CA 01 – Selection tool DT Configurator
The selection tool DT Configurator is available in conjunction with the
electronic catalog CA 01 on DVD.
MD 10.1
In addition, the DT Configurator can be used on the Internet without
requiring any installation.
The DT Configurator can be found in the Siemens Mall under the
following address:
www.siemens.com/dt-configurator
D 87.1
E86060-K5287-A111-A4-7600
Industrial Communication
SIMATIC NET
IK PI
E86060-K6710-A101-B7-7600
AC NEMA & IEC Motors
D 81.2
Further details available on the Internet
U.S./
at:
Canada
Only PDF
www.sea.siemens.com/motors
Products for Automation
and Drives
Interactive Catalog, DVD
E86060-D4001-A510-D3-7600
Industry Mall
Information and Ordering Platform
in the Internet:
www.siemens.com/industrymall
Further information on the subject of energy saving and the energysaving program SinaSave is available at the following address:
www.siemens.com/energysaving
E86060-K5710-A111-A4-7600
MOTOX Geared Motors
All information material, such as brochures, catalogs, manuals and
operating instructions for standard drive systems are available up-to-date
on the Internet at the following address:
The DT Configurator for motors, mechanical components, converters,
connection systems, control and licenses and system configuration can
be found in the CA 01 main menu, under drive systems, selection and
engineering tools.
• 2D/3D model generator for motors and converters
• Data sheet generator
• Start-up calculation
• Comprehensive product-specific documentation
Hardware and software requirements
• PC with 1.5 GHz CPU or faster
• Operating systems
– Windows XP
– Windows NT 4.0 (SP6 and higher)
– Windows Vista
– Windows 7
• At least 1 GB RAM (2 GB recommended)
• Screen resolution 1024 × 768, graphics with more than 256 colors,
small fonts
• DVD drive for offline version (CA 01)
• Windows-compatible sound card
• Windows-compatible mouse
Installation
CA 01
The CA 01 Catalog can be directly installed on the hard disk or in the
network from the DVD as a partial or full version.
© Siemens AG 2014
Motors
SIMOTICS FD
Flexible Duty Motors
Catalog D 81.8 · 04/2014
The products and systems described in this
catalog are manufactured/distributed under
application of a certified
quality management
system in accordance
with DIN EN ISO 9001
(Certified Registration
No. DE-000357 QM).
The certificate is
recognized by all IQNet
countries.
Please contact your local Siemens branch
Introduction
1
Technical Information
2
System Components
3
Self-ventilated motors –
enclosed version
4
Forced-air cooled motors –
enclosed version
5
Water-cooled motors
with water-jacket cooling
6
Water-cooled motors
with air-to-water heat exchanger
7
Self-ventilated motors –
open version
8
Forced-air cooled motors –
open version
9
© Siemens AG 2014
Printed on paper from
sustainably managed
forests and controlled
sources.
www.pefc.org
Explosion-proof motors
Technical Information
10
Article No. supplements and
special versions
11
Application-specific motors
12
Appendix
13
© Siemens AG 2014
2
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Answers for industry.
Integrated technologies, vertical market expertise and services
for greater productivity, energy efficiency, and flexibility.
The Siemens Industry Sector is the
world's leading supplier of innovative
and environmentally friendly products
and solutions for industrial companies.
End-to-end automation technology and
industrial software, solid market expertise, and technology-based services are
the levers we use to increase our customers’ productivity, efficiency and
flexibility. With a global workforce of
more than 100 000 employees,
the Industry Sector comprises the
Industry Automation, Drive Technologies, and Customer Services divisions,
as well as the Metals Technologies
Business Unit.
We consistently rely on integrated technologies and, thanks to our bundled
portfolio, we can respond more quickly
and flexibly to our customers' wishes.
With our globally unmatched range of
automation technology, industrial
control and drive technology as well
as industrial software, we equip companies with exactly what they need over
their entire value chain – from product
design and development to production,
sales and service. Our industrial customers benefit from our comprehensive
portfolio, which is tailored to their
market and their needs.
Market launch times can be reduced by
up to 50 % due to the combination of
powerful automation technology and
intelligent industrial software from
Siemens Industry. At the same time,
the costs for energy or waste water
for a manufacturing company can be
reduced significantly. In this way, we
increase our customers’ competitive
strength and make an important contribution to environmental protection
with our energy-efficient products and
solutions.
Siemens D 81.8 · 04/2014
3
© Siemens AG 2014
(53²(QWHUSULVH5HVRXUFH3ODQQLQJ
3/0²3URGXFW/LIHF\FOH0DQDJHPHQW
0DQDJHPHQW/HYHO
‡3URGXFW'HVLJQ
‡3URGXFWLRQ3ODQQLQJDQG6LPXODWLRQ
‡'DWD0DQDJHPHQW
0(6²0DQXIDFWXULQJ([HFXWLRQ6\VWHPV
6,0$7,&,7
2SHUDWLRQV/HYHO
0DLQWHQDQFH
$VVHW0DQDJHPHQW
6,0$7,&3&6
2SHUDWRU6\VWHP
(QHUJ\
0DQDJHPHQW
(QJLQHHULQJ
6WDWLRQ
7,$3RUWDO
&RQWURO/HYHO
6,0$7,&3&6
$XWRPDWLRQ
6\VWHPV
6,180(5,.
&RPSXWHU1XPHULF&RQWURO
6,027,21
0RWLRQ&RQWURO
6,0$7,&1(7
,QGXVWULDO
&RPPXQLFDWLRQ
6,0$7,&&RQWUROOHUV
0RGXODU3&EDVHG
)LHOG/HYHO
352),%863$
3URFHVV,QVWUXPHQWDWLRQ
7RWDOO\
,QWHJUDWHG
$XWRPDWLRQ
6,0$7,&'LVWULEXWHG,2
6,0$7,&,GHQW
,QGXVWULDO,GHQWLÀFDWLRQ
+$57
,2/LQN
Setting standards in
productivity and competitiveness.
Totally Integrated Automation.
4
Siemens D 81.8 · 04/2014
© Siemens AG 2014
TIA is characterized by its unique continuity.
It provides maximum transparency at all levels
with reduced interfacing requirements – covering
the field level, production control level, up to the
corporate management level. With TIA you also
profit throughout the complete life cycle of your
plant – starting with the initial planning steps
through operation up to modernization, where
we offer a high measure of investment security resulting from continuity in the further development
of our products and from reducing the number of
interfaces to a minimum.
3ODQW(QJLQHHULQJ
&2026
(WKHUQHW
6,0$7,&:LQ&&
6&$'$6\VWHP
The unique continuity is already a defined
characteristic at the development stage of
our products and systems.
,QGXVWULDO(WKHUQHW
6,0$7,&+0,
+XPDQ0DFKLQH,QWHUIDFH
The result: maximum interoperability – covering
the controller, HMI, drives, up to the process
control system. This reduces the complexity of
the automation solution in your plant. You will
experience this, for example, in the engineering
phase of the automation solution in the form of
reduced time requirements and cost, or during
operation using the continuous diagnostics facilities of Totally Integrated Automation for increasing the availability of your plant.
6,5,86,QGXVWULDO&RQWUROV
352),1(7
,QGXVWULDO(WKHUQHW
352),%86
6,1$0,&6'ULYH6\VWHPV
6,7233RZHU6XSSO\
$6,QWHUIDFH
.1;*$00$LQVWDEXV
/RZ9ROWDJH'LVWULEXWLRQ
7RWDOO\
,QWHJUDWHG
3RZHU
6,027,&60RWRUV
Thanks to Totally Integrated Automation, Siemens provides
an integrated basis for the implementation of customized
automation solutions – in all industries from inbound to
outbound.
Siemens D 81.8 · 04/2014
5
© Siemens AG 2014
Totally Integrated Power:
Future-proof power supply
from one source.
6
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Software tools, products, systems and
support for integrated electrical
power distribution
Energy Management/
Energy Transparency
Operation &
Monitoring
Load
management
Load curves
Forecast
Maintenance
Substation
Distribution
Maintenance
task
Status
reporting/
failure
management
Protocols
Power
Quality
DATE:
Cost center
EMPLOYEE
COST CENTER
PAY PERIOD BEGINNING
PAY PERIOD ENDING
DATE
SUN
MON
TUE
WED
THUR
FRI
SUN
MON
TUE
WED
THUR
FRI
SAT
SUN
TOTAL
IN
OUT
IN
OUT
OVERTIME
TOTAL HOURS
DATE
SAT
SUN
TOTAL
IN
OUT
U
I
cos o
P
W
IN
Hall 1
Distribution 3
Process/
industrial automation
Products & Systems
Infeed II
Renewables
Medium voltage with
protection technology
Air conditioning system
checkup
Replacing circuit
breaker contacts
Replacing meters
OUT
OVERTIME
TOTAL HOURS
central ON
OFF
local ON
OFF
tripped
Transformer
DATE
SUN
MON
TUE
WED
THUR
FRI
SAT
SUN
TOTAL
IN
OUT
IN
OUT
Building
automation
OVERTIME
TOTAL HOURS
Low voltage with
protection and measuring technology
≤ 110 kV
Planning Software Tools
The power supply system acts like a
“vital artery”, forming the basis for
the reliable and efficient functioning
of all electrically operated building
installations. Electrical power distribution therefore requires integrated
solutions. Our answer:
Totally Integrated Power (TIP).
This includes software tools and
support for planning and configuration
and a complete, optimally aligned
product and system portfolio for
integrated power distribution from
medium-voltage switchgear right to
socket outlets.
Network dimensioning
with SIMARIS design
Space requirements and budget calculation
with SIMARIS project
The power distribution products and
systems can be interfaced to building
or industrial automation systems
(Total Building Solutions or
Totally Integrated Automation) via
communication-capable circuit breakers
and components, allowing the full potential for optimization that an integrated solution offers to be exploited
throughout the project cycle – from
planning right through to installation
and operation.
Visualization of device characteristics
with SIMARIS curves
Get more information:
www.siemens.com/tip
www.siemens.com/simaris
www.siemens.com/specifications
Siemens D 81.8 · 04/2014
7
© Siemens AG 2014
Integrated Drive Systems
Faster on the market and in the black with Integrated Drive Systems
SIMOTICS FD is an important element of a Siemens Integrated Drive
System, contributing significantly to increased efficiency, productivity,
and availability in industrial production processes.
Horizontal, vertical, and lifecycle integration ensure that every drive
system component fits seamlessly into the whole system, into any
automation environment, and even into the entire lifecycle of a plant.
Integrated Drive Systems are Siemens’ trendsetting answer to the
high degree of complexity that characterizes drive and automation
technology today. The world’s only true one-stop solution for entire
drive systems is characterized in particular by its threefold integration:
The outcome is an optimal workflow – from engineering all the way
to service that entails more productivity, increased efficiency, and better availability. That’s how Integrated Drive Systems reduce time to
market and time to profit.
Horizontal integration
Integrated drive portfolio: The core elements of a fully integrated
drive portfolio are frequency converters, motors, couplings, and gear
units. At Siemens, they‘re all available from a single source. Perfectly
integrated, perfectly interacting. For all power and performance
classes. As standard solutions or fully customized. No other player in
the market can offer a comparable portfolio. Moreover, all Siemens
drive components are per fectly matched, so they are optimally
interacting.
You can boost the availability
of your application or plant
to up to
99%
*
*e.g., conveyor application
Vertical integration
Thanks to vertical integration, the complete drive train is
seamlessly integrated in the entire automation environment – an important prerequisite for production with
maximum value added. Integrated Drive Systems are
part of Totally Integrated Automation (TIA), which
means that they are perfectly embedded into the
system architecture of the entire industrial production process. This enables optimal processes through maximum communication
and control.
With TIA Portal you can
cut your engineering time
by up to
30%
Lifecycle integration
Lifecycle integration adds the factor of time: Software and
service are available for the entire lifecycle of an Integrated
Drive System. That way, important optimization potential for
maximum productivity, increased efficiency, and highest
availability can be leveraged throughout the system’s
lifecycle – from planning, design, and engineering to
operation, maintenance, and all the way
even to modernization.
With Integrated Drive Systems, assets
become important success factors. They
ensure shorter time to market, maximum
productivity and efficiency in operation,
and shorter time to profit.
With Integrated Drive
Systems you can reduce
your maintenance costs
by up to
15%
www.siemens.com/ids
8
Siemens D 81.8 · 04/2014
1
© Siemens AG 2014
Introduction
1/2
1/2
1/2
1/3
1/3
1/4
1/4
1/5
1/6
1/6
1/6
Orientation
Overview
The SIMOTICS family of motors
Performance features of the
SIMOTICS FD series
Overview of product lines
Benefits
Application
Technical specifications
Article number code
Overview
Structure of the article numbers for
SIMOTICS FD motors
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Introduction
Orientation
■ Overview
The SIMOTICS family of motors
With SIMOTICS, Siemens offers a comprehensive portfolio of
electric motors. From energy-efficient, low-voltage motors
through servomotors with high dynamic performance up to wellproven DC motors and powerful high-voltage motors. Innovative
drive technology for all industries, applications and performance
classes. Outstanding performance, quality, efficiency and
compactness.
SIMOTICS
Low-voltage motors for mains-fed and converter-fed operation
General Purpose
SIMOTICS GP
Severe Duty
SIMOTICS SD
Explosion-proof
SIMOTICS XP
Definite Purpose
SIMOTICS DP
Flexible Duty
SIMOTICS FD
DC Motors
High Voltage Motors
Direct Current SIMOTICS DC
High Voltage SIMOTICS HV
Transnorm
SIMOTICS TN
High Torque
SIMOTICS HT
Motors for Motion Control
SIMOTICS S Servomotors
SIMOTICS M Main Motors
SIMOTICS L Linear Motors
SIMOTICS T Torque Motors
G_D081_EN_00428
1
SIMOTICS – Low-voltage motors for mains-fed and
converter-fed operation
SIMOTICS low-voltage motors for mains-fed and converter-fed
operation are subdivided into seven segments depending on
the particular application.
• General Purpose – SIMOTICS GP
Motors for everyday applications in industry under standard
environmental conditions.
• Severe Duty – SIMOTICS SD
Motors with cast-iron housing for applications under harsh
environmental conditions.
• Explosion Protected – SIMOTICS XP
Motors for potentially explosive atmospheres.
• Definite Purpose – SIMOTICS DP
Special motors, e.g. smoke extraction motors or built-in
motors.
1/2
Siemens D 81.8 · 04/2014
• Flexible Duty – SIMOTICS FD
Converter-optimized motor series for flexible applications with
higher outputs in the range of 200 kW to over 1600 kW, with
various cooling methods. Water-cooled motors are also
offered for mains-fed operation.
• Transnorm – SIMOTICS TN
Motors with cast-iron housing with higher outputs in the range
of 145 kW to 1250 kW.
• High Torque – SIMOTICS HT
Permanent magnet synchronous motors for applications that
require extremely powerful drives without gear unit, even at
low speeds.
© Siemens AG 2014
Introduction
Orientation
1
■ Overview (continued)
Performance features of the SIMOTICS FD series
The SIMOTICS FD series is characterized by the following
features:
• Series of low-voltage motors optimized for converter-fed
operation
• Three product lines
- Air-cooled, enclosed version
- Water-cooled version
- Air-cooled, open version
• Wide output range from 125 kW to over 895 kW
in frame sizes 315 and 355
• Rugged cast-iron housing
A wide range of water-cooled motors is also available for
mains-fed operation.
The SIMOTICS FD motor series covers outputs from 200 kW and
higher (at 1500 rpm), and is available in a version optimized for
converter-fed operation with various cooling methods and as a
water-cooled version for mains-fed operation.
This motor series has an extremely long service life, is rugged
and ensures the highest availability thanks to various technical
details. For instance, KTY 84-130 temperature sensors are
integrated as standard in the winding as motor protection.
SIMOTICS FD motors are characterized by a very high output
with a small frame size. The result of this is an extremely compact design that saves space in a number of industrial applications.
SIMOTICS FD motors are not only optimized in terms of their design, but also in terms of their efficiency, so they also contribute
towards lower energy consumption.
The version optimized for converter-fed operation as part of a
drive system is harmonized for operation with SINAMICS lowvoltage frequency converters. Together with SINAMICS, it forms
an optimally harmonized drive system for variable-speed applications.
Overview of product lines
Air-cooled,
enclosed version
Water-cooled
version
Air-cooled,
open version
with
self-ventilation
with
forced-air cooling
with
with
water-jacket cooling heat exchanger
with
self-ventilation
with
forced-air cooling
Operation
VSD
VSD
DOL & VSD
VSD
VSD
VSD
Output
200 ... 590 kW
200 ... 595 kW
200 ... 735 kW
200 ... 840 kW
200 ... 850 kW
200 ... 895 kW
Cooling
method
IC411
IC416 1)
IC71W
IC86W
IC01
IC06 1)
Degree of
protection 2)
IP55
IP55
IP55
IP55
IP23
IP23
Features
Basic design
Low-noise or
increased output
High power density, High power density, Basic design
potable/fresh water seawater cooling
cooling
Primary load
M ~ n2
characteristic *)
T = const
T = const
M ~ n2
T = const
M ~ n2
M ~ n2
T = const
Motor type
Safe Area
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
Motor type
Ex n, Ex t 3)
1MM1
1MQ1
1MH1
1MN1
–
–
Low-noise or
increased output
VSD Variable Speed Drives (converter-fed operation)
DOL Direct On Line (mains-fed operation)
1)
2)
Cooling method IC37 (separately cooled using an external pipe system)
on request.
3)
Explosion-proof motors, Zones 2 and 22.
*)
M = Torque
Other degrees of protection optionally available.
Siemens D 81.8 · 04/2014
1/3
© Siemens AG 2014
Introduction
Orientation
1
■ Benefits
The SIMOTICS FD motor series has been specifically developed
for operation with SINAMICS converters. To supplement our
portfolio in the low-voltage motor range, a water-cooled version
for mains-fed operation has been created.
7 The optimized efficiency results in lower operating costs.
7 The high power density and compact design ensure low
space requirements combined with low weight.
7 A highly harmonized drive system is created as the motor is
optimally matched to the converter. For instance, it has optimized noise levels, the converter does not have to be derated
and the temperature rise is low.
7 The cast-iron housing and bearing plates are extremely rigid
and rugged and can therefore be subjected to considerable
stress. They have excellent vibration damping properties and
are resistant to corrosion.
7 The bearings are designed for maximum reliability, which results in good vibration characteristics, a long service life and
low maintenance costs.
7 The DURIGNIT IR 2000 insulation system with VPI or current
UV impregnation results in high reliability, a long service life
and high resistance to stress, for example, during starting or
under overload conditions.
7 Due to the low noise emission level, the stringent requirements
of occupational safety are fulfilled without the need for any
additional measures.
Greater output
With SIMOTICS FD, we have increased the power density so that
we offer higher outputs for the same frame size.
Optimized tuning for converter-fed operation
The new motor series has been optimized for operation on
SINAMICS G120P, G130, G150, S120, S120CM and S150 converters with regard to converter output currents and voltage
utilization.
Through the use of optimized pulse patterns and the new nonribbed housing, the SIMOTICS FD and frequency converter
system is noise optimized.
More flexibility
As a result of the new motor design, SIMOTICS FD motors fulfill
the most exacting customer requirements in terms of variance
and mounted options. For instance, the optimized motor design
allows terminal boxes, separately driven fans and mounted
coolers to be flexibly mounted as required and monitoring
devices can be added easily.
Improved design
The optimized housing in a modern design has an attractive appearance and enhances functionality with the flexible, modular
system. For instance, this is ensured by the optimized, easy to
access terminal box that has been newly developed, with
flexible terminal box position.
A wider range of applications
The motors are available in country and industry-specific versions, complying with the relevant regulations, standards and
directives.
■ Application
With their numerous options, the SIMOTICS FD motor series can
be used in all areas of industry. Paper, steel, energy, marine,
chemical, water/wastewater are some examples here.
The available types of construction are IM B3, IM B35 and IM V1
according to EN 60034-7. IP55/IP54 is the standard degree of
protection (IP23 for open-circuit ventilation).
1/4
Siemens D 81.8 · 04/2014
The wide field of applications that can be addressed includes,
for example, the following:
• Pumps
• Fans
• Compressors
• Cranes
• Propeller drives, bow thrusters
• Paper machines
• Winches
• Centrifuges
• Handling lines
• Conveyor belts
• Rolling mills
• Extruders
© Siemens AG 2014
Introduction
Orientation
1
■ Technical specifications
General technical specifications
Type of motor
SIMOTICS FD IEC low-voltage motors
Frame sizes
315, 355
Rated output
125 … 895 kW
Rated speed
750 ... 3600 rpm
Rated torque
610 … 4586 Nm
Versions
Air-cooled, enclosed version
• with self-ventilation
• with forced-air cooling
Water-cooled version
• with water-jacket cooling
• with heat exchanger
Air-cooled, open version
• with self-ventilation
• with forced-air cooling
Efficiency marking
For motors in mains-fed operation only
Efficiency class in accordance with IEC 60034-30: IE2, IE3 (4- and 6-pole)
Insulation of the stator winding
according to EN 60034-1
(IEC 60034-1)
Temperature class 180 (H)
DURIGNIT IR 2000 insulation system
Degree of protection
according to EN 60034-5
(IEC 60034-5)
As standard
IP55/IP54 Air-cooled, enclosed version; water-cooled version
IP23
Air-cooled, open version
Cooling
according to EN 60034-6
(IEC 60034-6)
• Self-ventilated 1LM1 motors (IC411)
• Forced-air cooled 1LQ1 motors (IC416)
• Water-cooled 1LH1 motors (IC71W)
• Air-water heat exchanger – 1LN1 motors (IC86W)
• Self-ventilated, open-circuit ventilated 1LL1 motors (IC01)
• Forced-air cooled, open-circuit ventilated 1LP1 motors (IC06)
Admissible coolant temperature
and site altitude
As standard
-20 ... +40 °C, site altitude up to 1000 m above sea level.
Standard voltages
according to EN 60038 (IEC 60038)
VSD: 50 Hz systems: 400 V, 500 V, 690 V 60 Hz systems: 460 V and 575 V
DOL: 50 Hz systems: 400 V and 690 V
60 Hz systems: 460 V
The voltage to be used can be found in the "Selection and ordering data" for the required motor.
Type of construction
according to EN 60034-7
(IEC 60034-7)
• Without flange: IM B3
• With flange: IM B35, IM V1
Paint finish
Suitability of paint finish for climate
group according to IEC 60721,
Part 2-1
Standard: color RAL 7030 stone gray
Vibration quantity level
according to EN 60034-14
(IEC 60034-14)
Level A (normal)
Optionally: level B (with special vibration requirements)
Shaft extension
according to DIN 748 (IEC 60072)
Balance type: half-key balancing as standard
Sound pressure level
according to EN ISO 1680
(tolerance +3 dB)
The sound pressure level is listed in the selection and ordering data for the required motor.
Weights
The weight is listed in the selection and ordering data for the required motor.
Modular mounting concept
Prepared for mounting of rotary pulse encoder or brake
Options
See "Supplements to article numbers and special versions"
Siemens D 81.8 · 04/2014
1/5
© Siemens AG 2014
Introduction
Article number code
1
■ Overview
Structure of the article numbers for SIMOTICS FD motors
The Article No. consists of a combination of digits and letters
and is divided into three hyphenated blocks to provide a better
overview, e.g.:
1LM1212-3AB31-1AA0
The first block (positions 1 to 7) identifies the motor series, system description and the efficiency; the second block (positions
8 to 12) defines the motor frame size, the number of poles as well
as the line voltage and frequency; and the third block (positions
13 to 16) encodes the speed, type of construction, terminal box,
separately driven fan and heat exchanger position.
Ordering data:
• Complete Article No. and order code(s) or plain text
• If a quotation has been requested, please specify the
quotation number in addition to the Article No.
• When ordering a complete motor as a spare part, please
specify the works serial No. for the previously supplied
motor as well as the Article No.
Note:
The structure of the Article No. of SIMOTICS FD motors supports
the widest possible range of combinations. To check a configured Article No., the selection guide DT Configurator must
be used.
The DT Configurator only permits technically implementable
Article Nos. to be configured.
Structure of the Article No.:
Position:
SIMOTICS FD low-voltage motors
Positions 1 to 4:
Motors without explosion protection
Digit, letter, letter, Motors with explosion protection
digit
Air-cooled, enclosed version with self-ventilation, IC411
Air-cooled, enclosed version with forced-air cooling, IC416
Water-cooled with water-jacket cooling, IC71W
Water-cooled with heat exchanger, IC86W
Motors exclusively without explosion protection
Air-cooled, open version with self-ventilation, IC01
Air-cooled, open version with forced-air cooling, IC06
Positions 5 to 7:
Motor series
Low-noise standard version
3 digits
Increased output version
Non-Siemens converter (standard)
Non-Siemens converter (increased output)
System description
Mains-fed operation (DOL)
Operation on SINAMICS converter with regulated infeed
Operation on SINAMICS converter with unregulated infeed
Operation on non-Siemens converter with regulated infeed
Operation on non-Siemens converter with unregulated infeed
Efficiency
High Efficiency
Premium Efficiency
Positions 8 and 9: Frame size
315
355
Digit, letter
400
450
Position 10:
No. of poles
4-pole
6-pole
Letter
8-pole
Position 11:
Laminated core length
Digit
Position 12:
Digit
Line voltage
Position 13:
Digit
Rated speed
Encoded with 1 … 9; 9 requires order code N.. (e. g. N1Y)
Position 14:
Letter
Type of construction
Encoded with A ... G, J … K
Position 15:
Letter
Terminal box position
Encoded with A … F one terminal box, K …P two terminal boxes
Position 16:
Digit
Separately driven fan – heat exchanger position
0:
No separately driven fan/heat exchanger,
1 … 4: Separately driven fan position for air-cooled motors,
5:
Heat exchanger, top
Special order versions:
Encoded – additional order code required
Not encoded – additional plain text required
1/6
1 2 3 4 5 6 7 - 8 9 10 11 12 - 13 14 15 16
1 L
1 M
M
Q
H
N
1 L L 1
1 L P 1
400 V, 50 Hz
500 V, 50 Hz
690 V, 50 Hz – VSD
690 V, 50 Hz – DOL
460 V, 60 Hz
575 V, 60 Hz
Deviating data requires order code M.. (e. g. M1Y)
Siemens D 81.8 · 04/2014
1
1
1
1
2
3
4
5
0
1
2
3
4
2
3
3
3
4
4
A
B
A
B
B
C
D
1
…
7
1
2
3
4
5
6
9
1
...
9
A
...
K
A
...
P
0
...
5
- Z
2
© Siemens AG 2014
Technical Information
2/2
2/2
2/2
Overview
SIMOTICS FD motor series
Versions of the SIMOTICS FD
motor series
2/4
2/4
Design
The basic design of the SIMOTICS FD
motor series
2/5
2/5
Technical specifications
Applicable standards and
specifications
Rating plate
Motors specially designed for
converter-fed operation
Rated voltage
Insulation
Noise
Forced-air cooling
Reducing bearing currents
Thermal torque limits
(continuous duty)
Maximum overload torques
More information
Water cooling
Mechanical load, grease lifetime
Motor protection
Motor connection
Motors specially designed for
mains-fed operation (1LH1)
Torque characteristic
Calculation of the start-up time for
direct-on-line starting
Start-up procedure for three-phase
motors with squirrel-cage rotor
Connection and terminal boxes
Terminal box mounting positions
Bearings and lubrication
Bearing assignment
Bearing lifetime (nominal lifetime)
Bearing system
Insulated bearings for converter-fed
operation
Regreasing
Grease lifetime and
regreasing intervals
Additional axial load for motors
in the basic version
Admissible cantilever forces at 50 Hz
for motors with reinforced bearings
2/6
2/6
2/6
2/6
2/7
2/7
2/7
2/8
2/8
2/9
2/9
2/9
2/9
2/9
2/9
2/9
2/10
2/11
2/12
2/12
2/13
2/13
2/13
2/13
2/14
2/14
2/14
2/14
2/15
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Technical Information
■ Overview
SIMOTICS FD motor series
2
1LL1 motors
The motors are squirrel-cage induction motors with compact
dimensions in a surface-cooled, open version with self-ventilation. The internal cooling circuit is supplied with cooling air from
the outside. This is the reason why the output was able to be
increased by approximately 30 % as compared to the 1LM1
motors. They have been specifically designed for converter-fed
operation.
Note:
For frame size 355 and rated speeds of 3000 rpm and above,
a shaft-mounted unidirectional fan is used.
The 1LL1 motors are designed for indoor use. They must not be
subjected to humid, salty or corrosive (e.g. hydrogen sulfide)
atmospheres.
A wide range of requirements are placed on state-of-the-art,
high-output, low-voltage motors. They should be energy efficient, able to be flexibly used, quiet in operation and optimally
adapted to the converter, for example. All of these requirements
are fulfilled by the SIMOTICS FD series of motors, which have
been specifically developed for this purpose. As a result of their
flexibility and the wide range of versions available, SIMOTICS FD
motors are suitable for all industries.
Versions of the SIMOTICS FD motor series
1LM1 motors
The motors are squirrel-cage induction motors with compact
dimensions in a surface-cooled, enclosed version with self-ventilation. They have been specifically designed for converter-fed
operation.
Note:
For frame size 355 and rated speeds of 3000 rpm and above,
a shaft-mounted unidirectional fan is used.
1LM1 for converter-fed operation
• Converter-fed operation, optimally harmonized to the
SINAMICS drive system
• Maximum A-weighted sound pressure level at rated speed is
79 dB(A) under no-load operation
• IP54/IP55 degree of protection
• Cooling method IC411, self-ventilated
• Housing: cast-iron
1LQ1 motors
The motors are squirrel-cage induction motors with compact
dimensions in a surface-cooled, enclosed version with forcedair cooling. These motors can be operated with constant torque,
also significantly below the rated speed, thanks to the forced-air
cooling. They have been specifically designed for converter-fed
operation.
1LQ1 for converter-fed operation
• Converter-fed operation, optimally harmonized to the
SINAMICS drive system
• Maximum A-weighted sound pressure level at rated speed is
79 dB(A) or 85 dB(A) under no-load operation
• IP54/IP55 degree of protection
• Cooling method IC416, forced-air cooling
• Housing: cast-iron
2/2
Siemens D 81.8 · 04/2014
1LL1 for converter-fed operation
• Converter-fed operation, optimally harmonized to the
SINAMICS drive system
• Maximum A-weighted sound pressure level at rated speed is
79 dB(A) under no-load operation
• IP23 degree of protection
• Cooling method IC01, self-ventilated
• Housing: cast-iron
1LP1 motors
The motors are squirrel-cage induction motors with compact
dimensions in a surface-cooled, open version with forced-air
cooling. The internal cooling circuit is supplied with cooling air
from the outside. This is the reason why the output was able to
be increased by approximately 35 % as compared to the 1LM1
motors. These motors can be operated with constant torque,
also significantly below the rated speed, thanks to the forced-air
cooling. They have been specifically designed for converter-fed
operation.
The 1LP1 motors are designed for indoor use. They must not be
subjected to humid, salty or corrosive (e.g. hydrogen sulfide)
atmospheres.
1LP1 for converter-fed operation
• Converter-fed operation, optimally harmonized to the
SINAMICS drive system
• Maximum A-weighted sound pressure level at rated speed is
79 dB(A) or 85 dB(A) under no-load operation
• IP23 degree of protection
• Cooling method IC06, forced-air cooling
• Housing: cast-iron
1LH1 motors
The motors are squirrel-cage induction motors with compact
dimensions in an enclosed, water-cooled version. This is the reason why the output was able to be increased by approximately
30 % as compared to the 1LM1 motors. These motors can be
operated with constant torque, significantly below the rated
speed, as a result of the water cooling. They have been specifically designed for converter-fed operation, and are also available in a version for mains-fed operation.
1LH1 for converter-fed operation
• Converter-fed operation, optimally harmonized to the
SINAMICS drive system
• Maximum A-weighted sound pressure level at rated speed is
79 dB(A) under no-load operation
• IP54/IP55 degree of protection
• Cooling method IC71W, water-cooled
• Water-jacket cooling with either a copper or stainless steel jacket
• Housing: cast-iron
© Siemens AG 2014
Technical Information
■ Overview (continued)
1LH1 for mains-fed operation
• Maximum A-weighted sound pressure level depending on the
number of poles 68 to 72 dB(A) under no-load operation
• IP54/IP55 degree of protection
• Cooling method IC71W, water-cooled
• Water-jacket cooling with either a copper or stainless steel
jacket
• Housing: cast-iron
1LN1 motors
The motors are squirrel-cage induction motors with compact
dimensions in a surface-cooled, enclosed version with air-towater heat exchanger. A separately driven fan is used to circulate air through the internal cooling circuit. This is the reason why
the output was able to be increased by approximately 30 % as
compared to the 1LM1 motors. These motors can be operated
with constant torque, significantly below the rated speed, as a
result of the forced-air cooling with air-to-water heat exchanger.
They have been specifically designed for converter-fed operation.
1LN1 for converter-fed operation
• Converter-fed operation, optimally harmonized to the
SINAMICS drive system
• Maximum A-weighted sound pressure level at rated speed is
79 dB(A) under no-load operation
• IP54/IP55 degree of protection
• Cooling method IC86W, air-to-water heat exchanger
• Housing: cast-iron
Siemens D 81.8 · 04/2014
2/3
2
© Siemens AG 2014
Technical Information
■ Design
The basic design of the SIMOTICS FD motor series
1LQ1 forced-air cooled motors – enclosed version
1LH1 water-cooled motors with water-jacket cooling
2/4
Siemens D 81.8 · 04/2014
G_D081_XX_00436
1LP1 forced-air cooled motors – open version
G_D081_XX_00435
1LL1 self-ventilated motors – open version
G_D081_XX_00434
G_D081_XX_00433
1LM1 self-ventilated motors – enclosed version
G_D081_XX_00432
G_D081_XX_00431
2
1LN1 water-cooled motors with air-to-water heat exchanger
© Siemens AG 2014
Technical Information
■ Technical specifications
Applicable standards and specifications
2
The SIMOTICS FD motors comply with the IEC 60034 series of
international product standards for rotating electrical machines
and, in particular, those parts that are listed in the table below.
Title
General specifications for rotating electrical machines
Specification of the losses and efficiency of rotating electrical
machines
Starting performance of rotating electrical machines
Terminal designations and direction of rotation for electrical machines
Designation for types of construction, mounting and terminal box
position (IM code)
Terminal box cable entries
Built-in thermal protection
Noise limits of rotating electrical machines
IEC standard voltages
Methods of cooling of rotating electrical machines (IC code)
Vibration severity of rotating electrical machines
Vibration limits
Degrees of protection for rotating electrical machines (IP code)
International efficiency classes for rotating electrical machines
(IE code)
In addition, the following applies to Ex motors:
General provisions
Type of protection "n" (non-sparking)
Areas containing flammable dust
IEC/EN
IEC 60034-1,
IEC 60085
IEC 60034-2-1
DIN EN
DIN EN 60034-1
IEC 60034-12
IEC 60034-8
IEC 60034-7
DIN EN 60034-12
DIN EN 60034-8
DIN EN 60034-7
–
IEC 60034-11
IEC 60034-9
IEC 60038
IEC 60034-6
IEC 60034-14
–
IEC 60034-5
IEC 60034-30
DIN 42925
DIN EN 60034-11
DIN EN 60034-9
DIN IEC 60038
DIN EN 60034-6
DIN EN 60034-14
DIN ISO 10816
DIN EN 60034-5
DIN EN 60034-30
IEC/EN 60079-0
IEC/EN 60079-15
IEC/EN 60079-31
DIN EN 60079-0
DIN EN 60079-15
DIN EN 60079-31
DIN EN 60034-2-1
Siemens D 81.8 · 04/2014
2/5
© Siemens AG 2014
Technical Information
■ Technical specifications (continued)
Rating plate
3~ Mot. 1LM1 222-3AB72-2AC0-Z
m: 1.78 t
IP 55
SIMOTICS FD
IM B3 Ta: -20…+40°C Th.Cl.:
180(H) Util.:155(F)
nmax: 2500 1/min IEC/EN 60034-1
U [V]
I [A]
480 D
550
P [kW] cosφ n [1/min] f [Hz]
395
0.90
1500
For SINAMICS converters (from firmware Version 4.6 and
higher), the SIMOTICS FD motor series can be selected as
motor category in the SINAMICS converter using the STARTER
commissioning tool software or on the converter operator panel
(AOP – Advanced Operation Panel).
Eff.
50.50
96.0%
Mot. design: FOR INVERTER DUTY ONLY
Rated voltage
UVW
DEW0400
Made in Germany D-90441 Nürnberg
G_D081_XX_00437
Line supply: 500V / 50Hz
3~ Mot. 1LH1 203-3AB71-2AB0-Z
IP 55
SIMOTICS FD
IM B3 Ta: -20…+40°C Th.Cl.:
I [A]
480 D
790
NoN- xx9900006050001/2013
P [kW] cosφ n [1/min] f [Hz] Eff. Class
465
0.88
1487
The rated motor voltages are selected so that when operated
with a SINAMICS converter, the available voltage is optimally
utilized.
Note:
180(H) Util.:130(B)
When operating at the limits of voltage ranges A and B, the temperatures and overtemperatures exceed the limits specified in
the standard. Under certain circumstances, this can affect the
service life (continuous duty with undervoltage, on request).
nmax: 1800 1/min IEC/EN 60034-1
U [V]
The tolerance for the rated voltage is in accordance with
DIN EN 60034-1. No rated voltage range is specified.
In addition to the line voltage, the type of converter infeed
(regulated or unregulated rectifier) defines the motor voltage that
is available. A converter with controlled rectifier always provides
the motor with a higher voltage than a converter with unregulated rectifier.
Example of a rating plate for 1LM1 for converter-fed operation
m: 2.0 t
When operated with an alternative converter, the catalog data
apply (thermal torque limits, maximum overload torques), with
the exception of the sound pressure level, under the following
boundary conditions:
• The converter is operated with a rated pulse frequency of at
least 2.5 kHz.
• The converter can provide the rated voltage as listed in the
catalog. This means that it is known whether the infeed
(rectifier) is regulated or unregulated.
If the infeed is unknown, an unregulated infeed should be
assumed, and the motor output should be reduced (please
inquire).
NoN- xx9900006060001/2013
50
IE3
Eff.
96.3%
Insulation
Mot. design: FOR DIRECT ON-LINE OPERATION ONLY
Line supply: 400V / 50Hz
MAX. WASSERDRUCK / WATER PRESSURE 5 BAR
Made in Germany D-90441 Nürnberg
DEW0400
KÜHLW./COOL.WATER 40 L/MIN, 35°C
G_D081_XX_00438
2
In accordance with EN 60034-1, the approximate total weight
is specified on the rating plate. An extra rating plate can be
supplied loose for all motors, order code K31.
An extra rating plate for identification codes is also possible,
order code Y82.
As standard, the rating plate is in English.
Example of a rating plate for 1LH1 for mains-fed operation
All motors that comply with the international standard
IEC 60034 30:2008 (Rotating electrical machines – Part 30:
Efficiency classes of single-speed, three-phase, cage-induction
motors (IE code)) have the efficiency class and the efficiency
stamped on the rating plate. These efficiencies are based,
according to the above standard, on the losses determined
in accordance with standard IEC 60034-2-1:2007.
The well-proven DURIGNIT IR 2000 insulation system is used
adapted to the motor and converter. The insulation system
corresponds to stress category or impulse insulation class (IIC)
C (significant stress according to the preliminary standard
DIN IES/TS 60034-18-41: 2007-04) for operation on a two-level
converter, and is subdivided into two categories. The level of
converter DC-link voltage and the rise times of the voltage are
important factors in the voltage stress of the winding:
• For a converter DC-link voltage of UDC,max < 700 V (line
voltage 500 V with unregulated infeed), the insulation system
IIC C 500 is used.
• For a converter DC-link voltage of over UDC = 700 V up to
UDC,max = 1035 V (line voltage 500 V with regulated infeed),
the insulation system IIC C 690 is used.
• The following applies for the voltage rise time: Ts > 0.5 µs.
Motors specially designed for converter-fed operation
For converter-fed operation with the outputs specified in the
catalog, the motors can be utilized corresponding to thermal
class 155 (F) (service factor 1.0).
These motors have been specifically designed for converter-fed
operation.
The catalog data – especially the sound pressure level at the
rated speed in no-load operation – are valid for operation with a
SINAMICS converter (from firmware Version 4.6 and higher).
In the case of a fault when connected to an IT supply system
(ground fault), the insulation is excessively stressed. In this
case, the process should be terminated as quickly as possible
(t < 2 h), and the fault resolved. We do not recommend operation
on TN supply systems with transition-point grounding.
2/6
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Technical Information
■ Technical specifications (continued)
Noise
Reducing bearing currents
The motors have been designed, so that at every rated speed a
maximum sound pressure level of
• LPA=79 dB(A) for self-ventilated, forced-air cooled motors and
motors with air-to-water heat exchanger (1LM1, 1LL1, 1LP1,
1LQ1, 1LN1) as well as with forced-air cooling in low-noise
version (1LQ1, 1LP1, position 5 of Article No. = 2)
• LPA = 85 dB(A) for motors with forced-air cooling in increased
output version (1LQ1, 1LP1, position 5 of Article No. = 3)
• LPA =78 dB(A) for water-cooled motors (1LH1)
To specifically reduce and prevent damage caused by bearing
currents, the system must be considered as a whole, which comprises the motor, converter, and driven machine. To prevent
damage caused by bearing currents, the SIMOTICS FD converter-fed motors are equipped with insulated bearings at NDE
as standard. Important factors which will help to prevent bearing
currents include:
• Set up a properly meshed grounding system in the system as
a whole, with low impedance for high-frequency currents
• No potential difference between the motor, converter, and
driven machine
- Use symmetrical, shielded connecting cables
- Connect the cable shield at both ends over the greatest
possible surface area (360° contact)
- Use equipotential bonding conductors between the motor
and the driven machine, the motor and the converter, within
the motor as well as between the terminal boxes and the HF
grounding position on the motor housing
• Attach iron cores above the motor connecting cable at the
converter output (selection and dimensioning through your
Siemens sales partner)
• Insulate a motor bearing
• Limit the voltage rate of rise by using an output filter to
dampen harmonic components in the output voltage
• Implement common-mode filter by employing damping cores
to reduce common-mode components
• Use converters with a low switching frequency
• Use cables with a symmetrical cable cross-section:
Forced-air cooling
The separately driven fans of motors of the 1LQ1 and 1LP1
series as well as the separately driven fans in the air-to-water
heat exchangers for the 1LN1 series are especially quiet. The
line voltage and frequency for the forced-air cooled motors are
specified, as for the motor itself, in position 12 of the Article No.
Technical specifications of the separately driven fan motor
(1LQ1, 1LP1) 1)
Frame 5th
size
position
of the
Article
No.
Mounting
position
Prated,
Irated,
Prated,
50 Hz
400 V,
50 Hz
60 Hz
Irated,
460 V,
60 Hz
kW
A
kW
A
315
2
radial
1.5
3.2
2.24
3.9
2
axial
1.75
3.2
o.r.
o.r.
3
radial
5.5
10.5
5.5
9.1
2
radial
1.5
3.2
2.24
3.9
2
axial
1.5
3.2
2.24
3.9
3
radial
5.5
10.5
5.5
9.1
355
L1
PE
L3 L2
Prated,
Irated,
Prated,
50 Hz
400 V,
50 Hz
60 Hz
Irated,
460 V,
60 Hz
kW
A
kW
A
315
3
6.1
3.45
5.8
355
5.5
6.3
10.3
9.9
1)
L1
PE
L3 L2
L3 L2
Technical specifications of the separately driven fan motor
(1LN1) 1)
Frame
size
L1
PE
Concentric
Cu or Al screen
PE
Steel reinforcement
G_D011_EN_00065
when operated with SINAMICS converters (from firmware
Version 4.6 and higher) in no-load operation is maintained.
The motor data on the rating plate can deviate from this.
Siemens D 81.8 · 04/2014
2/7
2
© Siemens AG 2014
Technical Information
■ Technical specifications (continued)
G_D081_EN_00442
0.4
0.8
1.2
2 n/nrated2.4
Thermal torque limit characteristic for the 1LP1 and 1LN1 series
0.4
0.8
1.2
1.6
2 n/n rated 2.4
Torque
Thermal torque limit characteristic for the 1LM1 series
G_D081_EN_00440
1.10
1.00
T/Trated
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
1.10
1.00
T/Trated
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
0
0.4
0.8
1.2
1.6
2 n/nrated 2.4
Speed
Thermal torque limit characteristic for the 1LH1 series
Maximum overload torques
0.4
0.8
1.2
1.6
2 n/nrated 2.4
Speed
Torque
1.10
1.00
T/Trated
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
0
G_D081_EN_00441
Thermal torque limit characteristic for the 1LL1 series
The maximum overload torque output from the motor is defined
by the overload torque characteristic over the complete speed
control range. The reference variable is the breakdown torque at
rated speed. The breakdown torque is calculated from the
breakdown torque ratio and the rated torque. Operation at the
maximum overload torque is only briefly permissible, for instance, when accelerating. The speed control range is limited
by the mechanical speed limit, which depends on the motor's
mechanical design.
0.4
0.8
1.2
1.6
2 n/nrated 2.4
Speed
1.10
1.00
T/T B
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
G_D081_EN_00444
0
0
0.4
0.8
1.2
SIMOTICS FD overload torque characteristic
Siemens D 81.8 · 04/2014
1.6
2 n/n N 2.4
Speed
Thermal torque limit characteristic for the 1LQ1 series
2/8
1.6
Speed
Speed
Torque
1.10
1.00
T/Trated
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
0
G_D081_EN_00443
1.10
1.00
T/Trated
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
0
G_D081_EN_00439
Torque
The thermal torque limit characteristics of the SIMOTICS FD
motor series define the maximum load torque for continuous
duty (S1) over the complete speed control range. The characteristics are different for all of the cooling methods. The speed
control range is limited by the mechanical speed limit, which
depends on the motor's mechanical design.
Torque
2
Torque
Thermal torque limits (continuous duty)
© Siemens AG 2014
Technical Information
■ Technical specifications (continued)
Torque characteristic
Water cooling
• The catalog data for motors with water cooling (1LH1) or with
air-to-water heat exchanger (1LN1) are applicable for the
following coolant flow rates:
• d[/dt = 40 l/min for the 1LH1 series
• d[/dt = 115 l/min for the 1LN1 series
• d[/dt = 150 l/min for the 1LN1 series (frame size 355)
The torque generated by a three-phase motor at its shaft varies
considerably within the speed range n = 0 to n = ns. The characteristic curve of the torque as a function of the speed of a
three-phase motor with squirrel-cage rotor is shown in the following diagram.
Motor protection
A motor protection function can be implemented using the I²t
sensing circuit implemented in the converter software. If required, more precise motor protection can be afforded by direct
temperature measurement using KTY84 sensors (standard
scope of delivery), Pt100 resistance thermometers or PTC
thermistors in the motor winding. Some converters from Siemens
determine the motor temperature using the resistance of the
temperature sensor. They can be set to a required temperature
for alarm and tripping. If Pt100 resistance thermometers are
ordered for winding temperature monitoring (order code A61)
or PTC thermistors (order code A12), the standard KTY84
temperature sensors are omitted. A combination of A25 and A61
or A25 and A12 is possible, additional charge on request.
KTY or Pt100 sensors are evaluated as described above, e.g. in
the converter.
For motors for mains-fed operation, the 3RS10 temperature
monitoring device that is part of the protection equipment can be
ordered separately. For further details, see Catalog IC 10.
Motor protection is implemented using basic insulation. If protective separation is required, this must be implemented when
designing the temperature monitoring system.
Motor connection
When connecting the motors, it is important to consider the
restrictions for mains-fed machines as well as the maximum
conductor cross-sections permitted for the converter.
Motors specially designed for mains-fed operation (1LH1)
The 1LH1 series also includes motors specifically for mains-fed
operation. Contrary to motors specifically for converter-fed
operation, it is possible to switch between star and delta connection.
TLR
Tp
Ta
T
Trated
TL
When motors are operated at speeds above the rated speed,
the mechanical smooth running operation and the bearings are
subjected to greater mechanical stress. This reduces the grease
lifetime and the bearing lifetime. More detailed information is
available on request. The SIMOTICS FD series optionally has
spent grease removal at both bearings.
TB
Tm
Mechanical load, grease lifetime
G_D081_EN_00200
More information
0
nrated ns
n
Trated
Tm
TL
Ta
Rated torque
Motor torque
Load torque
Acceleration torque
TLR Locked-rotor torque
TB Breakdown torque
Tp
Pull-up torque
nrated Rated speed
ns
Synchronous speed
The values for locked-rotor torque and breakdown torque as well
as for locked-rotor current for a specific motor can be found in
the selection and ordering data.
The limit for the mechanical overload capability is the breakdown torque. According to IEC/EN 60034-1, at rated voltage and
at rated frequency, induction motors must have an overload
capability of up to 160 % of the rated torque for 15 seconds.
If not agreed otherwise, for induction motors, the minimum pullup torque at rated voltage must have the value specified in the
following rated torques.
For three-phase motors without pole changing with a rated output equal to or greater than 100 kW, the following applies:
• 0.3 times rated torque and at least 0.5 times the locked-rotor
torque
According to IEC/EN 60034-1, the following tolerances are
admissible:
• For locked-rotor torque, from -15 to 25 % of the stated lockedrotor torque
• For locked-rotor current, up to 20 % of the stated locked-rotor
current without lower limit
• For the breakdown torque, up to -10 % of the specified breakdown torque
• For pull-up torque, -15 % of the guaranteed value.
Taking these tolerances into account, the locked-rotor torque
must be sufficiently higher than the breakaway torque of the
driven machine; and the motor torque must constantly exceed
the load torque during start-up until the operating speed is
achieved.
In the case of squirrel-cage motors, the locked-rotor torque and
breakdown torque are listed in the selection and ordering data
as multiples of the rated torque.
The normal practice is to start squirrel-cage motors directly on
line. The torque class indicates that with direct-on-line starting,
even if there is an undervoltage of 5 %, it is possible to start up
the motor against a load torque of
• 130 % (for CL 13)
• 100 % (for CL 10)
of the rated torque.
Siemens D 81.8 · 04/2014
2/9
2
© Siemens AG 2014
Technical Information
■ Technical specifications (continued)
The start-up time from n = 0 to n = nb can be approximately determined from the average acceleration torque.
tst =
300
0
20
60 80 % 100
Speed
40
Motors with CL 10 torque class
600
%
500
I
400
300
T
200
I
100
T
0
G_D081_EN_00202
maximum load torque during the starting
The total moment of inertia is made up of the motor moment of
inertia plus the moment of inertia of the driven machine and the
coupling or belt pulleys and is converted to the speed of the motor shaft.
Limit values for the start-up curve of three-phase squirrel-cage
motors for voltages up to and including 690 V are included in
IEC/EN 60034.
If problem-free starting is not possible due to a high moment of
inertia and/or a high load torque, a larger motor or a three-phase
motor with a SINAMICS frequency converter can be used for
SIMOTICS FD motors.
A mechanical solution for coping with heavy starting is to use a
starting coupling, whose application is limited by its capability to
absorb heat.
T
0
20
40 60 80 %100
Speed
G_D081_EN_00206
0
Start-up time in s
Total moment of inertia in kgm2
Operating speed in rpm
Average acceleration torque in Nm
tst
J
nop
Taav
T
200
∑ J nop
9.55 T aav
Tm
Taav
Torque and current
I
400
Torque
curves for
direct
starting
100
Torque and current
2
G_D081_EN_00201
Calculation of the start-up time for direct-on-line starting
600
%
500
Motors with CL 13 torque class
maximum load torque during starting
TL
The rated torque can be calculated as follows:
Trated= 9.55 Prated
1000
nrated
Trated Rated torque in Nm
nrated Rated speed in rpm
Prated Rated output in kW
The rated speed of the motor differs from the synchronous
speed by the slip srated.
Where:
srated=
ns – nrated
100
ns
srated Slip in %
Synchronous speed in rpm
nS
nrated Rated speed in rpm
2/10
Siemens D 81.8 · 04/2014
Tm
TL
Taav
nop
nop
n
Motor torque
Load torque
average acceleration torque
Operating speed
Determination of the average acceleration torque
© Siemens AG 2014
Technical Information
■ Technical specifications (continued)
0
20
40
60 % 80
200
300
400
%
500
n/n S
Unfavorable
star-delta starting
250
%
200
150
100
50
The locked-rotor current without a resistor or reactor is slightly
higher in both phases than with direct on-line starting.
0
TL
20
40
60 % 80
100
The electronic SIKOSTART motor starter can be used to better
implement starting based on this principle. This device limits the
torque and current while starting.
200
I/I rated
Any inquiries regarding start-up procedures must include the
following information:
1. Required output and rated speed of the driven machine
2. Planned motor speed
3. Load torque of the driven machine, depending on the speed
of the driven machine or the motor speed
4. Total external moment of inertia and rated speed of the driven
machine or referred to the motor speed
5. Number of starts in a specific time period and duty cycle or
6. Characteristics and number of operating cycles in a certain
time (method of braking)
TL
100
T/Trated
Soft starting for motors with squirrel-cage rotor can also be
achieved with short-circuit soft starting or a resistor can be connected in one phase during start-up. The locked-rotor torque
can be arbitrarily reduced with the help of this circuit.
G_D081_EN_00204
50
The torque curve can be approximately reduced by the square
of the voltage and the current curve linearly with the voltage by
reducing the voltage at the motor terminals with the help of a
starting transformer or starting resistors.
Starting at rated current is possible when using a converter
(second diagram).
150
2
G_D081_EN_00205
The first diagram shows a case in which star-delta start-up is not
appropriate because the excessive load torque causes the
premature switchover which in turn causes a high torque and
current surge that renders star-delta starting ineffective.
250
%
200
100
I/I rated
Three-phase motors with squirrel-cage rotors should, as far as
possible, be started directly on-line.
• It should be noted that for any specific motor, the torque and
current characteristics are given, independent of the load to
be started. Star-delta starting for motors with squirrel-cage rotor is to be used if low locked-rotor currents (e.g. specified by
the local power utility) or an especially low starting torque (soft
starting) is specified. Locked-rotor torque, breakdown torque
and all other torque values as well as the locked-rotor current
are 25 to 30 % of the values at direct-on-line starting.
• The motor torque must be sufficiently higher than the load
torque during start-up in the star stage. The change from star
to delta must not occur before approximately the operating
speed.
T/Trated
Start-up procedure for three-phase motors with squirrel-cage
rotor
300
400
%
500
n/n S
Correct
star-delta starting
Siemens D 81.8 · 04/2014
2/11
© Siemens AG 2014
Technical Information
■ Technical specifications (continued)
Connection and terminal boxes
Terminal box mounting positions
■
–
–
–
–
–
■
Both DE (right and left)
Both NDE (right and left)
–
–
–
–
✓ –
✓ 9) –
✓
✓
■
■
–
–
–
–
✓ –
✓ 9) –
8) 9)
8) 9)
–
Bottom
Top 4)
Right
–
–
–
✓ 7)
✓ 7)
✓ 7)
✓
■
■
✓
■
■
–
–
–
–
–
–
–
–
–
–
–
–
–
✓
✓
–
✓
✓
–
✓
✓
–
✓
✓
–
–
–
✓
✓ 7)
✓ 7)
■ 5)
■
■
■
■
■
–
–
–
–
–
■ 8)
–
–
–
–
✓ 8)
–
–
–
–
–
■ 8)
■ 8)
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
■ 8)
■ 8)
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
–
✓
■ 2)
■ 2)
✓
■
■
■
–
–
■
–
–
✓
–
–
✓
–
–
–
✓
✓
–
✓
✓
–
✓
✓
–
–
–
–
–
–
✓ 7)
✓ 7)
✓ 7)
✓
■
■
✓
■
■
–
–
–
–
–
–
–
–
–
–
–
–
–
✓
✓
–
✓
✓
–
✓
✓
–
✓
✓
–
–
–
✓
✓ 7)
✓ 7)
■
■
■
■
■
■
–
–
–
■ 2)
■
■ 8)
–
–
–
–
✓ 8)
–
–
–
–
–
■ 8)
■ 8)
✓
✓
–
–
–
✓
–
–
–
–
–
✓ 7)
–
–
–
■
■
–
–
–
–
–
–
–
–
–
–
–
■ 8)
■ 8)
✓
✓
–
–
–
✓
✓
–
–
–
–
✓ 7)
–
–
–
■
■
–
■
■
–
■
■
–
–
–
–
–
–
–
–
–
–
–
–
–
✓
✓
–
✓ 9)
✓ 9)
–
✓
✓
–
–
–
–
–
–
–
✓ 7)
✓ 7)
–
■
■
–
■
■
–
–
–
–
–
–
–
–
–
–
–
–
–
✓
✓
–
✓ 9)
✓ 9)
–
✓
✓
–
✓
✓
–
–
–
–
✓ 7)
✓ 7)
–
■
■
–
■
■
–
–
–
–
–
–
–
■
–
–
–
–
–
–
–
–
–
–
–
■
–
–
–
–
–
–
–
–
–
■
–
–
–
–
–
■
–
–
–
–
■
✓ 7) ■
–
–
–
–
✓ ✓
✓ 9) –
–
■
✓ 7) ■
–
–
–
–
✓ ✓
✓ 9) ✓
8) 9)
8) 9)
Left
–
✓
✓
–
–
–
DE
–
✓
✓
–
✓
✓
–
NDE
Bottom
NDE
–
Top 4)
✓
–
–
✓
–
–
Left
■
–
–
■
–
–
8) 9)
–
Right
DE
8) 9)
Both right (NDE and DE)
IM V1
✓
■
■
✓
■
■
1LM1, 1LQ1, 1LL1, 1LP1 motors – with IC411, IC416, IC01, IC06 cooling method
Version with one terminal box
Standard version (DE top) 3) 1
■ ✓ –
–
✓ ✓ ■ ✓ –
–
–
DE right 3) 10)
2
–
–
✓ –
✓ ■ –
–
✓ –
–
DE left 3) 10)
–
–
✓ –
✓ ■ –
–
✓ –
–
NDE top 6)
3
■ ✓ –
–
✓ ✓ ■ ✓ –
–
✓ 7)
NDE right 6) 10)
–
–
✓ –
✓ ■ –
–
✓ –
✓ 7)
6)
10)
NDE left
–
–
✓ –
✓ ■ –
–
✓ –
✓ 7)
Version with two terminal boxes
Both top (NDE and DE) 6)
4
■ 8) ✓ 8) –
–
–
–
■ 8) ✓ 8) –
–
–
Both left (NDE and DE) 6) 10)
–
–
■ 8) –
–
–
–
–
■ 8) –
–
Both right (NDE and DE) 6) 10)
–
–
■ 8) –
–
–
–
–
■ 8) –
–
Both DE (right and left)
–
–
–
–
–
–
–
–
–
–
–
Both NDE (right and left)
–
–
–
–
–
–
–
–
–
–
–
1LH1 motors – with IC71W cooling method
Version with one terminal box
Standard version (DE top)
2
■ ✓ –
–
✓ 2) ✓ 2) ■ ✓ –
–
–
DE right
–
–
✓ –
✓ 2) ■ 2) –
–
✓ –
–
DE left
–
–
✓ –
✓ 2) ■ 2) –
–
✓ –
–
NDE top
■ ✓ –
–
✓ ✓ ■ ✓ –
–
✓ 7)
NDE right
–
–
✓ –
✓ ■ –
–
✓ –
✓ 7)
NDE left
–
–
✓ –
✓ ■ –
–
✓ –
✓ 7)
Version with two terminal boxes
Both top (NDE and DE)
■ 8) ✓ 8) –
–
–
–
■ 8) ✓ 8) –
–
–
Both left (NDE and DE)
–
–
■ 8) –
–
–
–
–
■ 8) –
–
Both right (NDE and DE)
–
–
■ 8) –
–
–
–
–
■ 8) –
–
Both DE (right and left)
–
–
✓ –
✓ 2) ■ 2) –
–
✓ –
–
Both NDE (right and left)
–
–
✓ –
✓ ■ –
–
✓ –
✓ 7)
1LN1 motors – with IC86W cooling method
Version with one terminal box
DE top
–
–
–
–
–
–
–
–
–
–
–
Standard version (DE right)
–
–
✓ –
✓ ■ –
–
✓ –
–
DE left
–
–
✓ –
✓ ■ –
–
✓ –
–
NDE top
–
–
–
–
–
–
–
–
–
–
–
NDE right
–
–
✓ 9) –
✓ ■ –
–
✓ 9) –
✓ 7)
9)
9)
NDE left
–
–
✓ –
✓ ■ –
–
✓ –
✓ 7)
Version with two terminal boxes
Both top (NDE and DE)
–
–
–
–
–
–
–
–
–
–
–
Both left (NDE and DE)
–
–
■ –
–
–
–
–
■ –
–
NDE
IM B5 with support foot
DE
Bottom
Top 4)
Left
Right
IM B35
NDE
DE
Bottom
Top 4)
Fig. Type of construction 1)
on
IM B3
page
2/13 Cable entry
Left
Terminal box position
Right
2
8) 9)
8) 9)
–
■
✓ 7) ■
■ Standard version
✓ Combination is possible
1)
When ordering the optional type of construction IM V15, IM V5 or IM V6,
the position of the terminal box must be checked with regard to lifting
method, accessibility of feet bolts, etc.
2)
Not with terminal box 1XB1631.
3)
4)
5)
The radially mounted separately driven fan unit must be mounted on the
left or right side.
6)
The radially mounted separately driven fan unit cannot be mounted on the
same side as the terminal box.
If the terminal box and separately driven fan unit are both mounted on the
top, or on the same side, NDE cable entry is not possible for any terminal
box.
7)
Note bending radius, where applicable.
8)
The cable entries of the two terminal boxes must be mounted in the same
direction.
The position and direction "top" corresponds to the housing side opposite
to the one with feet mounted to it. For all types of construction, a housing
with feet is used, but in the case of IM V1, the feet are not used.
9)
Cable entry top, only when the water connection of the cooler is on
the other side.
10)
Not for 1LL1 and 1LP1 motors.
2/12
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Technical Information
■ Technical specifications (continued)
Fig. 1
Fig. 2
2
G_D081_XX_00449
G_D081_XX_00448
Fig. 3
Fig. 4
G_D081_XX_00451
G_D081_XX_00450
Bearings and lubrication
Bearing system
Bearing assignment
For the admissible vibration values measured at the bearing
plate, evaluation zones A and B specified in ISO 10816 are
applicable in order to achieve the calculated lifetime under
continuous duty. If higher vibration speeds will occur under the
operating conditions, special arrangements will be necessary
(please inquire).
The bearing selection tables are only intended for planning purposes. Authoritative information on the actual type of bearings
fitted in motors already supplied can be obtained by the factory
by quoting the serial number or can be read from the lubrication
plate.
No. of poles
Bearing design
Frame size
Design
DE
Bearing type
315
355
IM B3
6218 C3
Speed
Bearing lifetime
rpm
h
4
3000
40000
4
1500
40000
6
1000
40000
8
750
40000
NDE
Bearing type
6218 C3
IM B5/IM B35
6218 C3
6218 C3
IM V1
6218 C3
6218 C3
IM B3, K20
NU320E
6218 C3
IM B3
6220 C3
6220 C3
IM B5/IM B35
6220 C3
6220 C3
IM V1
7220 B +
6220 C3
6220 C3
IM B3, K20
NU322E
6220 C3
Bearing lifetime (nominal lifetime)
The nominal bearing lifetime is defined according to standardized calculation procedures (DIN ISO 281) and is reached or
even exceeded for 90 % of the bearings when the motors are
operated in compliance with the data provided in the catalog.
Generally, the bearing lifetime is defined by the bearing size, the
bearing load, the operating conditions, the speed and the
grease lifetime.
The bearing lifetime of motors with horizontal mounting is 40 000
hours if there is no additional axial loading at the coupling output
and 20 000 hours when utilized according to the maximum
admissible load.
In the basic bearing system, the floating bearing is situated at
the non-drive end (NDE) and the located bearing is situated at
the drive end (DE).
The bearing system is axially preloaded with a spring element to
ensure smooth running of the motor backlash-free.
This is not the case in versions with cylindrical roller bearings.
The bearings of these motors must always run under adequate
radial force (motors must not be operated on a test bed without
additional radial loads).
For increased cantilever forces (e.g. belt drives), reinforced
bearings can be used at the drive end (DE). Order code K20
Shaft seal and degree of protection
The standard degree of protection for the 1.M1, 1.Q1, 1.H1 and
1.N1 motor series is IP55. When the following operating speeds
are exceeded, the degree of protection falls to IP54:
• > 3000 rpm for frame size 315
• > 2670 rpm for frame size 355 (in combination with order code
M61 or K20: > 2430 rpm)
Siemens D 81.8 · 04/2014
2/13
© Siemens AG 2014
Technical Information
■ Technical specifications (continued)
2
Insulated bearings for converter-fed operation
Vertical installation – basic version
An insulated bearing is installed at NDE.
Speed
Regreasing interval up to CT 40 °C/
Grease quantity
rpm
Frame size
Regreasing
Regreasing with an M10 × 1 flat greasing nipple according to
DIN 3404 is provided.
315
355
Specifications for regreasing intervals, grease type and quantity
and any other data can be found on the lubrication plate or rating
plate.
750
6000 h/25 g
6000 h/50 g
1000
6000 h/25 g
6000 h/50 g
1500
5000 h/25 g
6000 h/50 g
Grease lifetime and regreasing intervals
1800
5000 h/25 g
–/–
Horizontal installation – basic version
2500
2500 h/25 g
–/–
Speed
Regreasing interval up to CT 40 °C/
Grease quantity
Horizontal installation (IM B3 only) for reinforced bearing (K20):
rpm
Frame size
Speed
Regreasing interval up to CT 40 °C/
Grease quantity DE/NDE
rpm
Frame size
315
355
750
6000 h/25 g
6000 h/30 g
1000
6000 h/25 g
6000 h/30 g
1500
1800
3000
3600
6000 h/25 g
6000 h/30 g
6000 h/25 g
6000 h/30 g
3000 h/25 g
2000 h/30 g
2000 h/25 g
2000 h/30 g
315
355
750
4000 h/45 g/20 g
4000 h/50 g/30 g
1000
3000 h/45 g/20 g
3000 h/50 g/30 g
1500
2000 h/45 g/20 g
2000 h/50 g/30 g
1800
1500 h/45 g/20 g
1500 h/50 g/30 g
Additional axial load for motors in the basic version
Additional axial load for motors in horizontal type of construction – basic version
Frame size Type
3000 rpm
1500 rpm
1000 rpm
750 rpm
Load direction
315
355
Tensile
Thrust
Tensile
Thrust
Tensile
Thrust
Tensile
Thrust
N
N
N
N
N
N
N
N
1..1…-…1.
3500
1900
4700
3100
5500
3900
6300
4600
1..1…-…3.
3500
1800
4700
3000
5500
3800
6200
4500
1..1…-…5.
3300
1700
4500
2900
5300
3600
6000
4300
1..1…-…7.
3300
1700
4500
2900
5300
3600
6000
4300
1..1…-…5.
4400
2100
6000
3700
6800
4500
7700
5400
1..1…-…7.
4400
2100
6000
3700
6700
4400
7700
5400
Tensile: additional axial load in DE direction
Thrust: additional axial load in NDE direction
Additional axial load for motors in vertical type of construction – basic version
Frame size Type
3000 rpm
1500 rpm
1000 rpm
750 rpm
Shaft extension pointing downwards
Load
315
355
downwards
upwards
downwards
upwards
downwards
upwards
downwards
upwards
N
N
N
N
N
N
N
N
1..1…-…1.
1100
6100
2400
7400
2700
8900
3500
9700
1..1…-…3.
600
6600
1900
7900
2000
9600
2800
10400
1..1…-…5.
100
7100
1400
8400
1500
10200
2300
11000
1..1…-…7.
–
7500 1)
1000
8800
1200
10500
2000
11300
1..1…-…5.
7800
7400
7800
8700
6200
11100
6200
11900
1..1…-…7.
7500
7700
7500
9000
5600
11700
5600
12500
Data for 3000 rpm and 1500 rpm are applicable to 4-pole motors.
Data for 1000 rpm and 750 rpm are applicable to 6- or 8-pole motors.
1)
Without additional axial load, the bearing lifetime is less than 20 000 h.
2/14
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Technical Information
■ Technical specifications (continued)
Motors in the basic version are designed for flexible couplings.
The following weight limits are admissible for coupling halves:
• Frame size 315 – 40 kg
• Frame size 355 – 60 kg
2
60
kN
50
FQ
FQ
x
inadmissible range
40
G_D081_EN_00452
Admissible cantilever forces at 50 Hz for motors, frame size 315,
in IM B3 type of construction with reinforced bearings
(order code K20)
30
FQ max
20
admissible range
10
9.315
inadmissible range
0
0
20
40
60
Bearings DE:
NDE:
Bearing lifetime:
Torsional torque:
Minimum cantilever force:
80
100
120
140 160 mm 180
x
NU320-E
6218
20 000 h
5600 Nm rising
9.315 kN
FQ
40
kN
35
FQ
x
inadmissible range
30
FQ Max
25
G_D081_EN_00463
Admissible cantilever forces at 50 Hz for motors, frame size 355,
in IM B3 type of construction with reinforced bearings
(order code K20)
20
admissible range
15
10.702
10
inadmissible range
5
0
0
50
100
150
200 mm 250
x
Bearings DE:
NU322-E
NDE:
6220
Bearing lifetime:
20 000 h
Torsional torque:
7500 Nm rising
Minimum cantilever force: 10.702 kN
The maximum cantilever force is limited to 40 kN.
Siemens D 81.8 · 04/2014
2/15
© Siemens AG 2014
Technical Information
Notes
2
2/16
Siemens D 81.8 · 04/2014
3
© Siemens AG 2014
System Components
3/2
3/2
3/2
3/2
3/2
3/2
3/3
3/3
3/3
3/4
3/8
3/10
3/10
3/11
3/11
3/11
3/11
3/12
Configuring
Configuring the motor
SIMOTICS FD
Structure of catalog motor
selection tables
Ambient conditions and site altitude
Duty types
Engineering the drive system
General information
Voltage supply via the converter
Engineering the drive system
Catalog versions and special versions
Noise emission for operation on
SINAMICS converter
EMC
Water cooling
(1LH1 and 1LN1 motors)
Cooling circuit in the application
Cooling water quality
Materials used in the motor
cooling circuit
Inhibitors, anti-freeze, biocides
3/13
3/13
Condition monitoring system
SIPLUS CMS condition monitoring
systems for the continuous condition
monitoring of motors
3/14
3/14
3/14
Couplings
Siemens Integrated Drive Systems
FLENDER couplings – Part of the
drive system
Siemens D 81.8 · 04/2014
© Siemens AG 2014
System Components
Configuring
Configuring the motor
■ Overview
SIMOTICS FD
3
Motors of the SIMOTICS FD series are designed for a wide range
of different applications. For outdoor use, special applications or
specific boundary conditions, an inquiry must be made to establish whether a catalog version is suitable or a special version is
recommended. This is particularly the case with:
• Applications with increased mechanical stress due to
vibration or shocks
• Installation on deck (ships)
• Frame sizes V15, V5 and V6
• Piston engines, hackers, crushers, shredders, shearing
machines
• Deviating rated motor voltages, speeds or outputs
Structure of catalog motor selection tables
The SIMOTICS FD motors have been optimized for operation
with converters of the SINAMICS range. The selection tables are
therefore structured as follows:
1. Motor type – cooling method (1LM1, 1LL1, 1LH1, …)
2. Line voltage/frequency (400 V, 50 Hz; 460 V, 60 Hz; …)
3. Type of infeed (regulated or unregulated)
4. Rated speed (1500 rpm, 1800 rpm, …)
In the selection tables, a SINAMICS converter is also recommended for each motor. The motor data is specified for operation on this converter, or on another converter that is comparable
with regard to the output voltage (section "Voltage supply").
Reduction factor kHT for non-standard site altitudes and/or
coolant temperatures for 1LH1 and 1LN1 water-cooled motors
Site altitude
above
sea level
Coolant temperature
(water)
m
≤ 25 °C
≤ 30 °C
≤ 35 °C
≤ 40 °C
≤ 45 °C
≤ 1000
1.00
0.95
0.90
0.84
0.79
≤ 1500
0.97
0.92
0.87
0.81
0.77
≤ 2000
0.94
0.89
0.85
0.79
0.74
Duty types
The operating data specified in the catalog for SIMOTICS FD
motors is applicable to duty type S1 (continuous duty according
to DIN EN 60034-1). Overloading is possible in the case of duty
types S2 (short-time duty), S3 (intermittent periodic duty) and S6
(continuous operation periodic duty). The applicable overload
factors can be taken from the tables below for these three duty
types.
The overload factors are valid on starting when the motor is cold
and when the resulting torque is less than or equal to the maximum overload torque (TB). If the motor is prewarmed due to recent operation or it is in a thermal steady-state due to continuous
duty (S1), thermal class 155 (F) will be exceeded under overload
conditions. Depending on the amount of overload, the maximum
winding temperature can be exceeded and the motor can be
damaged.
Overload factors for short-time duty (S2)
Ambient conditions and site altitude
Duty type
Short-time duty
The output data specified in the catalog is applicable to ambient
temperatures of -20 to 40 °C and site altitudes of up to 1000 m
above sea level. For ambient conditions outside this range,
derating is necessary.
S2
10 min
1.80
30 min
1.20
60 min
1.05
Reduction factor kHT for non-standard site altitudes and/or
coolant temperatures for 1LM1, 1LL1, 1LQ1 and 1LP1 air-cooled
motors
Intermittent periodic duty (S3)
Site altitude
above
sea level
Coolant temperature
(air)
For motor
1LM1, 1LL1
Duty type
m
30 °C … 40 °C ≤ 45 °C
≤ 50 °C
≤ 55 °C ≤ 60 °C
≤ 1000
1.00
0.96
0.92
0.87
0.82
≤ 1500
0.97
0.93
0.89
0.84
0.80
≤ 2000
0.94
0.90
0.86
0.82
0.77
For water-cooled motors, the data specified in the catalog is
based on a coolant inflow temperature of 25 °C, whereby
derating is necessary for a coolant temperature of 25 °C and
a site altitude of > 1000 m.
Deviating installation conditions can be clarified on request.
Factor
S3
Intermittent
periodic duty
1LQ1, 1LP1,
1LH1, 1LN1
Factor
60 %
1.16
1.22
80 %
1.02
1.07
Continuous operation periodic duty (S6)
Duty type
Periodic duty
S6
25 %
Factor
1.70
40 %
1.35
60 %
1.18
With 1LQ1, 1LP1, 1LH1 and 1LN1, it is not permitted for the
cooling to be interrupted.
3/2
Siemens D 81.8 · 04/2014
© Siemens AG 2014
System Components
Configuring
Engineering the drive system
■ Overview
The SIMOTICS FD motors have been specially tuned to the
converters of the SINAMICS G130, SINAMICS G150,
SINAMICS S120, SINAMICS S150 and SINAMICS G120P series.
SIMOTICS FD must be selected as the motor type during
commissioning of the SINAMICS converter in the STARTER
commissioning tool, or in the user interface.
The motors can also be operated with other converters under
certain boundary conditions.
General information
For optimum dimensioning of the motors with regard to heating
and noise emission for converter-fed operation, the following
details are necessary:
• Type of infeed
• Maximum voltage available to the motor
• Converter pulse frequency, if applicable
• Required rated speed
• Required rated output, cooling method and degree of
protection of the motor (selection tables)
The insulation system of the motors corresponds to thermal
class 180 (H). The motors are utilized in accordance with
thermal class 155 (F) as standard. For utilization of the motors
in accordance with thermal class 130 (B), the output must be
reduced by 14 % (derating factor 0.86).
Voltage supply via the converter
To select a catalog version of the SIMOTICS FD motor series
specifically designed for converter-fed operation, the voltage
available to the motor must be known. The line voltage and the
configuration of the converter at the line side (infeed, rectifier
or line-side converter – referred to below as the infeed) are
important here.
M
Supply
system
Infeed
DC link
Inverter
G_D081_EN_00453
The SIMOTICS FD motor series offers scope for optimizing the
drive system that comprises the frequency converter and the
motor with regard to different criteria. This focuses on the following motor characteristics:
• Increased efficiency:
SIMOTICS FD motors specially designed for converter-fed
operation are characterized as standard by a high degree of
efficiency – comparable to IE2 motors for mains-fed operation.
For selected cooling methods (IC411 –1LM1 self-ventilated,
IC416 – 1LQ1 forced-air cooled, IC71W – 1LH1 water-cooled),
motors with increased efficiency are also available – comparable to IE3 motors for mains-fed operation. For motors with
increased efficiency (position 7 of the Article No. = 3) in frame
size 315, depending on the individual case, the thermal
utilization for converter-fed operation can also comply with
thermal class 130 (B) instead of thermal class 155 (F). The
specified efficiencies are applicable for motor voltages in
accordance with DIN EN 60034-1 N.
• Minimal noise emission for operation on SINAMICS
converters:
Noise emission is minimized, especially in the range of rated
speed, thanks to a perfectly matched drive system comprising a SINAMICS converter and SIMOTICS FD motor. This has
been achieved on the one hand with a new electrical and mechanical design of the motor, and on the other hand using a
new pulse pattern in the SINAMICS converter series that has
been specially optimized for SIMOTICS FD motors.
• Optimum voltage utilization:
The voltage supplied by the converter is optimally utilized.
This reduces the motor current and has a positive effect on the
converter either in the form of higher current reserves or lower
costs for the Motor Module.
Motor
Drive system
Unregulated infeed
If the infeed involves a line-commutated converter (unregulated
infeed), i.e. a thyristor or diode rectifier (in some cases also an
IGBT module), the maximum available motor voltage is lower
than the line voltage. The DC link voltage and, therefore, also the
output voltage of the converter is not normally regulated and
changes as soon as fluctuations in line voltage occur.
The SINAMICS converter series comprises two different variants
of unregulated infeed:
• Basic Infeed – SINAMICS G130, SINAMICS G150,
SINAMICS S120 Basic Line Module (BLM, SINAMICS G120P):
- Line-commutated converters
- Suitable for infeed operation (two-quadrant operation)
- Power semiconductors: thyristors/diodes
- Line harmonics: total harmonic distortion factor of the line
current THD(I) up to 45 %
- Low voltage load on motor winding
- Low price, compact size
• Smart Infeed – SINAMICS S120 Smart Line Modules (SLM):
- Line-commutated converters
- Suitable for operation in infeed and regenerative feedback
mode (four-quadrant operation)
- Power semiconductors: IGBT modules
- Line harmonics: total harmonic distortion factor of the line
current THD(I) up to 45 %
- Low voltage load on motor winding
- Medium price, medium size
The maximum voltage supplied to the motor by the converter in
the case of SINAMICS converters (with optimized pulse pattern)
is:
UMotor max = 0.97 · Uline
With converters of the SINAMICS G130 and SINAMICS G150
series, SINAMICS S120 Basic Line Modules, SINAMICS S120
Smart Line Modules and SINAMICS G120P, it is ensured at full
line voltage (position 12 of the Article No.) that the rated motor
voltages specified in this catalog are available.
If an alternative converter is to be used, it must be established
in the context of project engineering that the rated motor voltage
can be provided by the converter. Otherwise, the motor current
rises and there is a risk of excessive motor temperature which
reduces the service life.
Siemens D 81.8 · 04/2014
3/3
3
© Siemens AG 2014
System Components
Configuring
Engineering the drive system
■ Overview (continued)
3
Regulated infeed
Engineering the drive system
If the infeed involves a self-commutated converter (regulated infeed), the maximum available motor voltage is higher than the
line voltage. The DC link voltage and, therefore, also the output
voltage of the converter is normally regulated so it is independent of any fluctuations in line voltage.
A motor should be selected (according to voltage, speed and
torque) following engineering of the drive system to ensure that
all the potentials that arise from the motor and converter combination can be exploited. The motors of the SIMOTICS FD series
are specifically matched to the SINAMICS converter series. This
results in additional system advantages, such as reduced noise
emission.
For converters of the SINAMICS S150 series that are equipped
with an Active Line Module as well as SINAMICS S120 with
Active Line Modules, the following applies:
• Self-commutated converter
• Suitable for operation in infeed and regenerative feedback
mode (four-quadrant operation)
• Power semiconductors: IGBT modules
• Line harmonics: total harmonic distortion factor of the line
current THD(I) up to 3 %
• With reference to the supply network, with factory settings
cosϕ = 1
• Higher voltage load on the motor winding than for unregulated
infeed
The maximum voltage supplied to the motor by the converter in
the case of SINAMICS converters (with optimized pulse pattern)
is:
UMotor max = 1.11 · Uline
With converters of the SINAMICS S120 series with Active Line
Modules and SINAMICS S150, it is ensured that the rated motor
voltages specified in this catalog are available.
If an alternative converter is to be used, it must be established
in the context of project engineering that the rated motor voltage
can be provided by the converter. Otherwise, the motor current
rises and there is a risk of excessive motor temperature which
reduces the service life.
3/4
Siemens D 81.8 · 04/2014
In contrast to simple selection of a motor, drive system engineering takes into account that the converter also contributes towards loading of the motor winding due to non-sinusoidal voltage and current.
In this catalog, SIMOTICS FD motors specially designed for converter-fed operation are offered for the following line voltages:
• 400 V, 50 Hz
• 500 V, 50 Hz
• 690 V, 50 Hz
• 460 V, 60 Hz
• 575 V, 60 Hz
Motors for other line voltages can be supplied on request.
Depending on the type of infeed, it is possible to choose between motors whose rated voltages either lie below the line voltage (unregulated infeed) or above the line voltage (regulated infeed). Depending on which information is available for the drive
system to be engineered, engineering can be performed in
accordance with one of the two subsequent detail levels.
© Siemens AG 2014
System Components
Configuring
Engineering the drive system
■ Overview (continued)
Options for engineering the drive system
Detail level 1
Detail level 2
Simple motor selection – details of the converter are not known
Engineering the drive system – details of the converter are
known – certain properties of the drive system can be optimized
Engineering goal
• Selection of a motor specifically for converter-fed operation
• Selection of a motor specifically for converter-fed operation
• Optimum voltage utilization (low-cost drive system without derating of
converter or motor)
• Low noise emissions
Preconditions
• Line voltage is known
• Required rated speed is known
• Motor will only be operated on the converter
• Type of infeed, or the converter, are unknown
• Line voltage is known
• Required rated speed is known
• Motor will only be operated on the converter
• Type of infeed is known
• For operation on the SINAMICS converter, the rated pulse frequency is
1.25 kHz or more.
• For operation on an alternative converter, the pulse frequency is 2.5 kHz
or more.
Engineering tasks
• Selection of the line voltage or inquiry about other line voltages
(position 12 of Article No.)
• Selection of a catalog version for the unregulated infeed
(position 6 of the Article No.:
2 for SINAMICS converter or 4 for alternative converter)
• Rated output of motor is reduced by the factor 0.85
• Selection of the line voltage or inquiry about other line voltages
(position 12 of Article No.)
• Selection of a catalog version for:
- Unregulated infeed (position 6 of Article No.:
2 for SINAMICS converter or 4 for alternative converter)
- Regulated infeed (position 6 of Article No.:
1 for SINAMICS converter or 3 for alternative converter)
• The catalog data is applicable for operation on SINAMICS converter
and under the described preconditions for operation on alternative
converters (with the exception of sound pressure levels)
Advantages of the drive system
• The required rated motor voltage is available.
• Irrespective of the pulse frequency, type of infeed and converter type,
compliance with the thermal class specified in the catalog is assured.
• The required rated motor voltage is available and will be optimally
utilized.
• For operation on SINAMICS converter:
- Low-noise motor (LPA ≤ 79 dB(A))
- Integration in the "STARTER commissioning tool" software and the
Advanced Operation Panel (AOP) of the converter
- Operation of a motor with a winding system on two parallel converter
motor modules is possible as standard
- Recommendation of a SINAMICS converter for the respective
catalog version
- Optimized pulse pattern for SIMOTICS FD
Constraints with unknown converter
• Rated output of motor is reduced by the factor 0.85
• For operation on an alternative converter, the specified
A-weighted sound pressure level is only a guide value due to the
• The A-weighted sound pressure level specified cannot be used for
engineering because the pulse frequency and the modulation technique unknown modulation technique.
of the converter are unknown.
• Operation with optimized pulse patterns is normally assumed. If operation with space-vector modulation is planned, constraints may exist with
regard to the pulse frequency and operation of a motor with a winding
system on a SINAMICS converter with two parallel motor modules.
Siemens D 81.8 · 04/2014
3/5
3
© Siemens AG 2014
System Components
Configuring
Engineering the drive system
■ Overview (continued)
A motor can also be selected without precise knowledge of the
converter. In this case, the motor is the central focus of the engineering and not the drive system and its optimization. Simple
motor selection focuses on the large majority of applications for
which an unregulated infeed is sufficient and the functions of a
regulated infeed (e.g. four-quadrant operation or low line harmonics) are not required. Applications in which an unregulated
infeed is normally sufficient include excavators, conveyor drives,
bow thrusters, wood chippers, centrifugal pumps, fans, mills,
propellers, pumps or shredders. Even in applications with a quadratic torque characteristic, regulated infeed is not normally
required.
Engineering at detail level 2 involves, in addition to the motor
selection, engineering of an optimized drive system due to
knowledge of the converter – especially the infeed – with regard
to:
• Noise emission (for operation on SINAMICS converter)
• Voltage utilization and therefore motor or converter current
consumption
• Output and torque or frame size
M
For engineering at detail level 1, the line voltage must be known.
U line
M
Uline ; f line
Urated ; Irated
Urated ; Irated
UDC
Infeed
f Pulse ; I L
G_D081_EN_00455
Engineering the drive system – detail level 2
G_D081_EN_00454
3
Simple motor selection – detail level 1
Prated ; T rated ; n rated ; L PA
Drive system – engineering of the drive system at detail level 2
For engineering at detail level 2, the following must be known:
• Line voltage and, where applicable, line frequency
• Unregulated or regulated infeed
• Rated pulse frequency of the converter
Prated ; Trated ; n rated
Drive system – simple motor selection (detail level 1)
When selecting a SIMOTICS FD motor from the catalog, it is
important to note:
• For all line voltages, the versions for unregulated infeed are
required.
• The converter must be able to provide the rated voltage of the
motor. Otherwise, the motor current rises and there is a risk of
excessive motor temperature which reduces the service life of
the motor.
• Due to the unknown infeed and modulation technique of the
converter, the rated output specified in the catalog must be
reduced (reduction factor 0.85).
• The maximum A-weighted sound pressure levels specified
in the catalog cannot be used, because the modulation
technique of the converter is unknown.
When selecting a SIMOTICS FD motor from the catalog, it is
important to note:
• For each combination of line voltage and infeed, a
SIMOTICS FD motor can be selected that optimally utilizes the
available converter output voltage.
• For operation on SINAMICS converter (firmware 4.6), operation is already possible from the rated pulse frequency
fPulse = 1.25 kHz upwards without derating.
• If the converter is not a SINAMICS G130, SINAMICS G150,
SINAMICS S120, SINAMICS S150 or SINAMICS G120P, the
pulse frequency must be at least 2.5 kHz, otherwise the risk of
excessive motor temperature rise and noise emission prevails.
• The maximum A-weighted sound pressure levels specified
are applicable for operation on SINAMICS G130,
SINAMICS G150, SINAMICS S120, SINAMICS S150 or
SINAMICS G120P converters.
Rated motor voltages according to line voltage and infeed
Line voltage Uline
400 V
460 V
500 V
575 V
690 V
Line frequency fline
50 Hz
60 Hz
50 Hz
60 Hz
50 Hz
Line voltage –
position 12 of
Article No.
1
5
2
6
3
Infeed
Unregulated
Regulated Unregulated
Regulated Unregulated
Regulated Unregulated
Regulated Unregulated
Regulated
System description –
position 6 of
Article No.
2; 4
1; 3
2; 4
1; 3
2; 4
1; 3
2; 4
1; 3
2; 4
1; 3
Rated motor voltage
Urated
380 V
425 V
440 V
480 V
480 V
520 V
550 V
610 V
660 V
730 V
Insulation system
IIC C 500
When the motor is selected correctly, it operates with optimized
pulse patterns from approximately 87 % of the rated speed
upwards.
3/6
Siemens D 81.8 · 04/2014
IIC C 690
If operation with space-vector modulation is planned, the
converter pulse frequency (also in the case of SINAMICS
converters) must be at least 2.5 kHz or the motor output must
be reduced (see the following section for derating factors).
© Siemens AG 2014
System Components
Configuring
Engineering the drive system
■ Overview (continued)
SIMOTICS FD motor on SINAMICS converter
The SIMOTICS FD motors are designed for operation with
optimized pulse patterns. The optimized pulse patterns for
SIMOTICS FD are only implemented when
• the motor type is selected as "SIMOTICS FD" on commissioning (SINAMICS parameter p300),
• the motor is operated with optimized pulse patterns
(SINAMICS parameter p1802 = 19). With SINAMICS G
converters, parameters are assigned automatically when
the motor type is selected, and with SINAMICS S converters,
they are assigned manually.
• Note: with SINAMICS S converters, space-vector modulation
is preset and can be changed manually depending on the
application to optimized pulse patterns for SIMOTICS FD. For
certain applications (e.g. multi-axis drives), it is not admissible
for SINAMICS S converters to be operated with optimized
pulse patterns.
3
The thermal torque limit characteristic takes into account the
transition from space-vector modulation at speeds significantly
below the rated speed with optimized pulse patterns at speeds
of approx. 87 % of the rated speed upwards (see diagram
below).
For motors with a rated speed of 3600 rpm and a supply
frequency of around 120 Hz, it must be noted that the rated
pulse frequency of the converter has to be increased to 2.5 kHz.
This can result in derating of the converter.
1.10
1.00
T/Trated
0.80
0.70
0.60
0.50
0.40
0.30
0.20
0.10
0.00
G_D081_EN_00456
Torque
If the application requires that the converter is operated with
optimized pulse patterns for SIMOTICS FD motors for speeds
above approx. 87 % of the rated speed with space-vector
modulation, the rated motor output must be reduced as follows
in accordance with the rated pulse frequency of the converter:
• Space-vector modulation with rated pulse frequency of
1.25 kHz: derating factor 0.85
• Space-vector modulation with rated pulse frequency of
2 kHz: derating factor 0.95
• Space-vector modulation with rated pulse frequency of
2.5 kHz: derating factor 1
Space-vector
modulation
0
0.4
Optimized
pulse patterns
(optimized for SIMOTICS FD)
0.8
1.2
1.6
Selection of SIMOTICS FD in the STARTER commissioning tool
SIMOTICS FD motor on alternative converters
If a SIMOTICS FD motor is operated on an alternative converter
that does not belong to the SINAMICS series G130, G150, S120,
S150 or G120P, it is important to note the following:
• The selection and ordering data with the exception of the
A-weighted sound pressure level for operation on a SINAMICS
converter also applies to operation on an alternative converter
when the rated motor voltage is available and the rated pulse
frequency of the converter is at least 2.5 kHz.
• The A-weighted sound pressure levels specified for operation
on a SINAMICS converter do not apply for operation on an
alternative converter due to the unknown modulation technique.
• A distinction is made between the standard version (position 5
of Article No. = 4 for series 1.M1, 1.L1, 1.P1, 1.Q1, 1.H1 and
1.N1) and the increased output version (position 5 of
Article No. = 5 for series 1.P1 and 1.Q1).
• A distinction is made between regulated infeed (position 6
of Article No. = 3) and unregulated infeed (position 6 of
Article No. = 4).
2.0n/nrated 2.4
Speed
Modulation techniques and thermal torque limit
Siemens D 81.8 · 04/2014
3/7
© Siemens AG 2014
System Components
Configuring
Engineering the drive system
■ Overview (continued)
Catalog versions
Rated motor speeds
3
To select a catalog version, in addition to the available voltage
(see section "Voltage supply") the required motor speed must
also be known. The rated speeds of the catalog versions are
assigned to the line supplies listed in this section in accordance
with the line frequency. For the line voltages 400 V, 500 V and
690 V, catalog versions are available with the rated speeds
• 750 rpm
• 1000 rpm
• 1500 rpm
• 3000 rpm
For the line voltages 460 V and 575 V, catalog versions are
available with the rated speeds
• 900 rpm
• 1200 rpm
• 1800 rpm
• 3600 rpm
Due to the converter supply, the rated motor speed does not
depend on the line frequency. The rated speeds of 750 rpm to
1200 rpm are covered by the 6-pole version and the rated
speeds of 1500 rpm to 3600 rpm are covered by the 4-pole
version. If other rated motor speeds are required, it can be
clarified on request whether it is necessary for the windings to be
modified.
Recommended SINAMICS converters
In the catalog, a suitable converter of the SINAMICS series is
assigned to every motor of the SIMOTICS FD series that is
specially designed for converter-fed operation. This assignment
is a recommendation. If the complete drive system is to be
ordered, engineering of the drive system is required in accordance with detail level 2.
Converter assignment is based on the following assumptions:
• The rated motor current corresponds to the reduced baseload current IL of the converter for the standard load cycle
"Minimal overloading of the converter" (see diagram below).
The current IL is slightly less than the rated output current of
the converter (by approx. 3 to 6 %).
• The line voltage assumed on motor selection is available to the
converter.
• For converters with unregulated infeed, cabinet units of the
SINAMICS G120P or SINAMICS G150 series are recommended.
• For converters with unregulated infeed, it is assumed that no
special requirements exist (e.g.: line harmonics) and infeed
operation will be used exclusively (no regenerative feedback
– two-quadrant operation).
• For converters with regulated infeed, cabinet units of the
SINAMICS S150 series are recommended.
• When converters of the SINAMICS series are recommended,
chassis units can also be used as an alternative.
3/8
Siemens D 81.8 · 04/2014
For the reduced base-load current IL of the overall converter, the
following applies in the case of parallel connection of two power
units:
• For connection in parallel, the SINAMICS S150 should be
replaced with SINAMICS S120 CM. For SINAMICS S120 CM in
the version with parallel connection of motor modules, the
reduced base-load current IL for the single device is doubled
and the total current is reduced by 5 %.
Converter current
10 s
1.5 x IL
Short-time current 150 %
Short-time current 110 %
Rated current (continuous)
Base load current IL
for low overload
1.1 x IL
Irated
IL
G_D213_EN_00035
Catalog versions and special versions
60 s
300 s
t
Definition of the standard load cycle "Minimal overloading of the
converter"
Due to the numerous assumptions on which the assignment of
converters of the SINAMICS series is based, it must be ensured
that the assumptions quoted actually apply for the planned
application when the drive system is engineered. This must
apply for every point, otherwise the recommendation is invalid,
especially:
• When the motor is to be operated with short-time or periodic
overloading, and currents higher than the rated motor current
are necessary. Note: not all rated motor currents fully utilize
the reduced base-load current of the converter, which is why
the recommended converter may already have current reserves. For evaluating existing current reserves, the rated
motor current can be compared to the respective reduced
base-load current of the converter (see table below).
• When operation with space-vector modulation is planned, the
converter is not operated with the optimized pulse patterns for
SIMOTICS FD motors. In this case, the pulse frequency of the
converter must be at least 2.5 kHz or the output must be
reduced.
• Furthermore, with unregulated infeed and operation exclusively in space-vector modulation, the motor only has a
maximum voltage available to it of
UMotor max. = 0.92 · Uline
© Siemens AG 2014
System Components
Configuring
Engineering the drive system
■ Overview (continued)
Reduced base-load currents IL of the SINAMICS converters (SINAMICS G120P, SINAMICS G150 and SINAMICS G130 or
SINAMICS S150 and SINAMICS S120 technically comparable) – for engineering purposes, IL can be regarded as equal to the
motor current
Output
kW
Number IL
of
motor
modules A
fP
Type
kHz
Number IL
of
motor
modules A
fP
Type
kHz
Number IL
of
motor
modules A
fP
Type
kHz
3
SINAMICS G120P, SINAMICS G150 converters – unregulated infeed
Urated,Motor,min/Urated,Motor,max: 380/480 V
Urated,Motor,min/Urated,Motor,max: 500/600 V
Urated,Motor,min/Urated,Motor,max: 660/690 V
75
–
–
1
80
1.25 1SL3710-1GH28-5AA3
90
–
–
1
95
1.25 1SL3710-1GH31-0AA3
110
1
200
2
6SL3710-1PE32-1AA0
1
171
1.25 6SL3710-1GF31-8AA3 1
115
1.25 1SL3710-1GH31-2AA3
132
1
240
2
6SL3710-1PE32-5AA0
1
208
1.25 6SL3710-1GF32-2AA3 1
142
1.25 1SL3710-1GH31-5AA3
160
1
290
2
6SL3710-1PE33-0AA0
1
250
1.25 6SL3710-1GF32-6AA3 1
171
1.25 1SL3710-1GH31-8AA3
200
1
360
2
6SL3710-1PE33-7AA0
1
320
1.25 6SL3710-1GF33-3AA3 1
208
1.25 1SL3710-1GH32-2AA3
250
1
450
2
6SL3710-1PE34-6AA0
1
400
1.25 6SL3710-1GF34-1AA3 1
250
1.25 1SL3710-1GH32-6AA3
315
1
570
1.25 6SL3710-1PE35-8AA0
1
452
1.25 6SL3710-1GF34-7AA3 1
320
1.25 1SL3710-1GH33-3AA3
355
–
640
2
6SL3710-1PE36-6AA0
–
400
1
710
1.25 6SL3710-1PE37-4AA0
1
560
1.25 6SL3710-1GF35-8AA3 1
400
1.25 1SL3710-1GH34-1AA3
450
1
820
1.25 6SL3710-1GE38-4AA3 –
1
452
1.25 1SL3710-1GH34-7AA3
560
1.25 1SL3710-1GH35-8AA3
–
500
–
1
710
1.25 6SL3710-1GF37-4AA3 –
560
1
960
1.25 6SL3710-1GE41-0AA3 1
790
1.25 6SL3710-1GF38-1AA3 1
630
2
1092 1.25 6SL3710-2GE41-1AA3 2
836
1.25 6SL3710-2GF38-6AA3 –
710
2
1340 1.25 6SL3710-2GE41-4AA3 2
1036 1.25 6SL3710-2GF41-1AA3 1
710
1.25 1SL3710-1GH37-4AA3
800
–
–
1
790
1.25 1SL3710-1GH38-1AA3
900
2
1516 1.25 6SL3710-2GE41-6AA3 –
–
1000 –
2
1314 1.25 6SL3710-2GF41-4AA3 2
1120 –
–
–
1200 –
–
–
1036 1.25 6SL3710-2GH41-1AA3
SINAMICS G120P, SINAMICS G150 converters – regulated infeed
Urated,Motor,min/Urated,Motor,max: 380/480 V
Urated,Motor,min/Urated,Motor,max: 500/730 V
75
–
1
80
1.25 6SL3710-7LG28-5AA3
90
–
1
95
1.25 6SL3710-7LG31-0AA3
110
1
205
2
6SL3710-7LE32-1AA3
1
115
1.25 6SL3710-7LG31-2AA3
132
1
250
2
6SL3710-7LE32-6AA3
1
142
1.25 6SL3710-7LG31-5AA3
160
1
302
2
6SL3710-7LE33-1AA3
1
170
1.25 6SL3710-7LG31-8AA3
200
1
370
2
6SL3710-7LE33-8AA3
1
208
1.25 6SL3710-7LG32-2AA3
250
1
477
2
6SL3710-7LE35-0AA3
1
250
1.25 6SL3710-7LG32-6AA3
315
1
590
1.25 6SL3710-7LE36-1AA3
1
320
1.25 6SL3710-7LG33-3AA3
355
–
400
1
725
1.25 6SL3710-7LE37-5AA3
1
400
1.25 6SL3710-7LG34-1AA3
450
1
820
1.25 6SL3710-7LE38-4AA3
1
452
1.25 6SL3710-7LG34-7AA3
500
–
560
1.25 6SL3710-7LG35-8AA3
1.25 6SL3710-7LG37-4AA3
560
–
–
960
1.25 6SL3710-7LE41-0AA3
1
630
–
–
710
1
1230 1.25 6SL3710-7LE41-2AA3
1
710
800
1
1370 1.25 6SL3710-7LE41-4AA3
1
790
1.25 6SL3710-7LG38-1AA3
900
–
1
880
1.25 6SL3710-7LG38-8AA3
1000 –
1
1000 1.25 6SL3710-7LG41-0AA3
1120 –
–
1200 –
1
1230 1.25 6SL3710-7LG41-3AA3
More information about SINAMICS converters can be found in the SINAMICS Engineering Manual.
Siemens D 81.8 · 04/2014
3/9
© Siemens AG 2014
System Components
Configuring
Engineering the drive system
■ Overview (continued)
Case 1 can be described with the Article No. without an additional order code. For case 2 and case 3, the appropriate order
codes and plain text details are required.
• Non-standard line voltage (position 12 of Article No.: 9):
Order code M1Y and non-standard line voltage and/or rated
motor voltage specified in plain text
• Non-standard rated speed (position 13 of Article No.: 9):
Order code N1Y and non-standard rated speed specified in
plain text
L PA,
rated
Constant flow
range
Rated range
nrated
Field-weakening
range
Speed
Non-standard motor and load data possible on request.
The variants of the SIMOTICS FD motor series that can be selected in the catalog have been designed such that the maximum A-weighted sound pressure levels listed in the tables below are not exceeded in no-load operation at the rated operating
point when connected to a SINAMICS converter.
This has been achieved thanks to the following measures:
• Optimized electrical design: reduced, electromagnetic noise
generation
• Optimized mechanical design: improved radiation characteristics
• The choice of rated voltages, whereby the maximum converter
output voltages supplied are optimally utilized
• Operation of the SINAMICS converter with an optimized pulse
pattern: reduced electromagnetically generated noise,
especially in the range of the rated speed ("rated range" in
the diagrams below).
• Choice of suitable built-in fan (for 1LM1 and 1LL1):
limiting of the aerodynamic noise
• Dimensioning of new separately driven fan: limiting of the
noise from the separately driven fan
Motors of the SIMOTICS FD series can be selected in the
"STARTER commissioning tool" software and in the Advanced
Operation Panel (AOP) as a motor type. This ensures that
operation using the named modulation technique is assured for
all SIMOTICS FD motors in the respective range close to the
rated speed.
A-weighted sound pressure levels under no-load operation on
SINAMICS converter at rated speed (tolerance +3 dB
SIMOTICS FD series
LPA in dB(A)
1LM1, 1LL1, 1LN1
79
1LQ1, 1LP1 (position 5 of Article No. = 2)
(position 5 of Article No. = 3)
79
85
1LH1
78
3/10
Siemens D 81.8 · 04/2014
Schematic diagram of sound pressure level (1LM1, 1LL1)
L PA,
rated
Constant flow
range
Rated range
nrated
Field-weakening
range
G_D081_EN_00458
Noise emission for operation on SINAMICS converter
Sound pressure level
3
For versions of the SIMOTICS FD series that are not listed in the
catalog, individual inquiries regarding winding modification are
necessary. A winding modification may be required for:
1. A combination of defined supply and rated speed codes that
are not listed in the catalog.
2. Non-standard supply systems for which a code has not been
defined.
3. Non-standard rated speeds for which a code has not been
defined.
G_D081_EN_00457
Modified windings – Special versions for non-standard
voltage or speed
For engineering a noise-optimized system, it is therefore
important to:
• Select a motor with a rated voltage that matches the line
voltage and the infeed of the SINAMICS converter.
• Select a motor with a rated speed that is lower than or equal
to the speed(s) to be expected during operation.
• Upgrade the hardware and software of the SINAMICS converter if an existing SINAMICS converter (position 16 of the
SINAMICS Article No. 0, 1 or 2) is to be used.
Sound pressure level
Special versions
Speed
Schematic diagram of sound pressure level (1LP1, 1LQ1, 1LH1, 1LN1)
The noise emission was able to be reduced in particular close to
the rated speed (rated range). If a constant torque drive (mainly
1LP1, 1LQ1, 1LH1 and 1LN1) is implemented for low noise
generation, it must be ensured during engineering that the lower
operating speeds remain within the rated range. This can be
achieved, for example, through the correct choice of rated
speed. In self-ventilated motors (1LM1, 1LL1), the aerodynamic
noise generated by the built-in fan dominates with increasing
speed above the rated range. For drives of this type, the high
operating speeds must be close to the rated speed.
EMC
The system comprising SIMOTICS FD in combination with
SINAMICS has been checked according to the guidelines for
electromagnetic compatibility 2004/108/EC and the regulations
of the EMC directives. System compatibility is only provided with
EMC-compliant grounding and if shielded power cables are
used whose shield is conductively bonded over a large area to
the metal motor terminal box.
© Siemens AG 2014
System Components
Configuring
Water cooling (1LH1 and 1LN1 motors)
■ Overview
Cooling circuit in the application
Cooling water quality
When water-cooled motors of the SIMOTICS FD series (1LH1,
1LN1) are operated in the application, they become part of the
overall cooling circuit. Apart from the cooling unit, this can
include other heat sources.
The water-cooled versions of the SIMOTICS FD series offer solutions for different qualities of cooling water. The optimum cooling
water quality can therefore be selected in accordance with the
location and application. The following tables contain the water
properties defined for the various motor versions.
The construction of the cooling materials demands two completely different cooling concepts for the overall cooling circuit in
the application.
For the coolant circuit in SIMOTICS FD motors of the 1LH1 and
1LN1 series, the materials listed in the table "Materials used in
the motor (cooling circuit)" can be deployed which provides the
user with a range of possibilities for constructing the cooling
circuit.
Definition of water properties
Water quality
Potable
water
Fresh water Sea water
6.5 to 8.0
6.0 to 9.5
6.5 to 10
–
< 0.9
pH value
–
Carbon-related
hardness
mMol/l –
Total hardness
mMol/l < 2.5
< 1.7
< 1.8
Chloride ions (Cl-)
mg/l
< 200
< 3000
Sulfate ions (SO42-)
mg/l
< 50
< 240
< 3000
Sulfide ions (S2-)
mg/l
–
–
<1
Please read the following definitions for clarification:
Nitrate ions (NO3+)
mg/l
< 50
< 50
< 50
1. Closed cooling circuit:
The pressure compensator is closed (no ingress of oxygen)
and fitted with a pressure-relief valve (6 bar for 1LN1 motors,
3 bar for 1LH1 motors); it is always connected on the suction
side of the pump. The coolant is only routed through the
SIMOTICS FD motors, the components required for cooling
and, if necessary, a converter. The materials used in the
cooling circuit comply with the recommendations in the table
"Admissible materials for the overall cooling circuit".
Iron (Fe3+)
mg/l
–
–
<1
Ferromanganese ions mg/l
(Fe3+Mn2+)
–
–
< 50
Ammoniac (NH3)
Ammonium (NH4+)
mg/l
–
–
< 15
Alkalinity
mg/l
< 300
–
–
Dissolved substances mg/l
< 340
< 340
< 340
Electrical conductivity µS/cm < 500
< 2000
< 32000
2. Semi-open cooling circuit:
Oxygen can only enter the coolant through the pressure
compensator, otherwise the cooling circuit corresponds to a
closed cooling circuit.
Size of entrained
particles (sand)
mm
< 0.1
< 0.1
< 0.1
Biological
growth
resistant
No
No
Yes
The electrochemical processes that take place in a cooling system must be minimized by choosing the right materials. For this
reason, mixed installations, i.e. a combination of different materials, such as copper, brass, iron, zinc, or halogenated plastic
(PVC hoses and seals), should not be used or should be limited
to the absolutely essential minimum.
3. Open cooling circuit:
The coolant is guided through the motors and the cooling
components required for heat dissipation as well as through
components external to the cooling circuit. The materials
used comply with the minimum requirements specified in the
table "Admissible materials for the overall cooling circuit".
< 50
Assignment of motor versions to cooling water quality
Water quality
to motor cooling
Motor type
1LH1
1LN1
Potable water
✓
✓
Possible cooling circuits of the SIMOTICS FD motor series
Fresh water
✓ 1)
✓
Type
Sea water
–
✓
Type of cooling circuit
Closed
Semi-open
Open
Materials used in the motor cooling circuit
1LH1
✓
–
–
1LN1
✓
✓
–
Motors of the 1LH1 series are equipped with built-in cooling
pipes constructed from copper as standard, or as an option from
stainless steel (order code M85).
For further information on the construction of a cooling circuit,
see the Manual "SINAMICS S120 – Chassis Liquid Cooled Power
Units".
Motors of the 1LN1 series are equipped with a double-walled
air-to-water heat exchanger. The materials used in the 1LH1 and
1LN1 series are listed in the table below.
Materials used in the motor (cooling circuit)
1)
Motor type
Materials
1LH1 (standard)
Cu, stainless steel (V2A), CuZn39Pb3
1LN1 (standard)
CuNi (90/10) RILSAN® plastic-coated
steel
With order code M85.
Siemens D 81.8 · 04/2014
3/11
3
© Siemens AG 2014
System Components
Configuring
Water cooling (1LH1 and 1LN1 motors)
■ Overview
3
Admissible materials for the overall cooling circuit
Inhibitors, anti-freeze, biocides
Material
Coolant additives
1LH1
1LH1
with
order
code
M85,
1LN1
Comment
Aluminum
–
✓
Zinc
✓
✓
Can be used in closed circuits
with inhibitor.
Brass
✓
✓
Can be used in closed circuits
with inhibitor.
Copper
✓
✓
Can be used in closed circuits
with inhibitor.
Common steel
(e.g. St 37)
✓
✓
Permissible in closed circuits
with inhibitors or anti-freeze,
check for oxide formation,
inspection window recommended.
Cast steel/
cast-iron
✓
✓
High-alloy steel,
Group 1 (V2A)
✓
✓
High-alloy steel,
Group 1 (V2A)
✓
✓
PVC
–
–
Hoses
✓
✓
Reduce use to a minimum.
Must not be used as the main
pipe for the whole system.
Effectiveness regarding the growth of microorganisms.
3/12
Siemens D 81.8 · 04/2014
1LH1
1LH1
with
order code
M85
1LN1
Inhibitor without
anti-freeze effect
Required
NALCO
TRAC100
0.2 % < X ≤
0.25 %
Not
required
Not
required
Anti-freeze
Antifrogen N
20 % < X ≤ 45 %
Antifrogen L
25 % < X ≤ 48 %
Varidos FSK
25 % < X ≤ 45 %
Antifrogen N
20 % < X ≤ 45 %
Antifrogen L
25 % < X ≤ 48 %
Varidos FSK
25 % < X ≤ 45 %
Biocide 1)
Yes
Antifrogen N,
minimum quantity 20 %
Antifrogen L,
minimum quantity 30 %
Varidos FSK,
minimum quantity 30 %
Not required
Anti-freeze +
biocide
When Antifrogen N
> 20 % or Antifrogen L/
Varidos FSK > 30 % is used, an
adequate biocidal effect exists.
Closed circuit and use of
strainers and flushback filters.
✓ Admissible
– Inadmissible
1)
Material
© Siemens AG 2014
System Components
Condition monitoring system
SIPLUS CMS condition monitoring systems for
the continuous condition monitoring of motors
■ Overview
The SIPLUS CMS condition monitoring systems continuously
monitor the condition of wear-prone drive components such as
motors. Depending on the system, individual motors can be
monitored as well as complete drive trains, or even the entire
plant. IEPE sensors are used for acquisition of the motor vibrations for analysis, visualization and archiving by SIPLUS CMS.
Information is supplied regularly and event-driven – also under
remote operation. SIPLUS CMS can also be retrofitted.
3
More information on SIPLUS CMS is available on the Internet at:
www.siemens.com/siplus-cms
SIPLUS CMS X-Tools for further
analysis
Remote access
e. g. via cRSP/ePS
SCADA
e. g. via WinCC, PCS7,
Maintenance Station
SIMATIC IPC
SP01_00026
Ethernet
SIPLUS CMS2000
Configuration:
1 Basic Unit VIB
1 VIB-MUX
2 temperature modules
Binary signals
LAN
SIMATIC controller
Up to 16 IEPE vibration sensors
for modular connection
Additional monitoring:
• Speed
• Temperature measurement (Pt100, Pt1000, ...)
• e. g. pressure sensors via analog inputs
Drive train:
Drive
Gear
Bearing
Pump
Siemens D 81.8 · 04/2014
3/13
© Siemens AG 2014
System Components
Couplings
Siemens Integrated Drive Systems
■ Overview
Integrated drive portfolio:
3
The core elements of a fully integrated drive system are frequency converters, motors, couplings and gear units. Siemens
offers all the required components in top manufacturing quality
from a single source, perfectly integrated – operating perfectly
together, for all performance classes.
As a standard solution or tailored to individual requirements. No
other provider on the market is able to offer a comparable portfolio. All Siemens drive components are optimally tuned to each
other so that they interact ideally in every application.
Because of the environment, the coupling has to meet a large
number of additional requirements. Couplings must be as suitable for use in a potentially explosive environment as for use at
a high or low ambient temperature. The environment may be
defined as chemically aggressive or be subject to laboratory
conditions or requirements of food manufacture.
Standard construction types of Siemens FLENDER couplings for
SIMOTICS FD motors
Type
Description
N-EUPEX
Flexible cam coupling
• Universally implementable coupling for compensation
of shaft misalignment
• Suitable for plug-in installation and easy assembly with
three-part design
Rated torque: 19 … 62000 Nm
RUPEX
Flexible pin and bush coupling
• Fail-safe, universal coupling for medium to very high
torques with a good misalignment range
• Compact design, low weights and mass moments of
inertia
• Suitable for plug-in assembly
Rated torque: 200 … 1300000 Nm
ZAPEX
Gear couplings
• Double-jointed coupling compensates for angular,
parallel and axial misalignment
• Long-term lubrication through design measures and
the use of special seals
• Small dimensions
• Can be used for high shock loads
Rated torque: 1300 … 7200000 Nm
ARPEX
All-steel couplings
• Zero-backlash, torsionally rigid coupling
• For compensating radial, angular, and axial shaft
misalignment by means of two flexible lamella
packages made of stainless spring steel
• Easy assembly thanks to compact lamella packages
Rated torque: 92 … 1450000 Nm
Siemens Integrated Drive Systems turn simple drive components into real systems. Drive technology based on IDS ensures
maximum productivity, energy efficiency and reliability in every
automation environment and over the entire product lifecycle.
FLENDER couplings – Part of the drive system
A drive system comprises individual machines, including the
motor and gear unit. Couplings combine these components and
frequently also establish the connection to the driven machine.
The coupling can perform other tasks in addition to the transmission of rotary motion and torque, such as:
• Compensation for shaft misalignment with low restorative
forces
• Influencing of intrinsic torsional frequency and damping
• Overload: interruption or limitation of torque
• Electrical insulation, noise insulation
• Function in explosive environments
Couplings are frequently planned after the machines to be connected have already been selected. Thanks to a large number
of different coupling assembly options, specified boundary
conditions for installation space and connection geometry can
be met from the catalog standard. The coupling also performs
secondary functions, such as the provision of the brake disk or
brake drum for operational or holding brakes, devices to record
speed or the addition of chain wheels or belt pulleys.
3/14
Siemens D 81.8 · 04/2014
© Siemens AG 2014
System Components
Couplings
Siemens Integrated Drive Systems
■ Overview (continued)
Shaft misalignment
Shaft misalignment is the result of displacement that occurs
during assembly and operation and, where machines constructed with two radial bearings each rigidly coupled, will cause
high loads being placed on the bearings. Elastic deformation of
base frame, foundation and machine housing will lead to shaft
misalignment which cannot be prevented, even by precise
alignment. Furthermore, because individual components of the
drive train heat up differently during operation, heat expansion
of the machine housings causes shaft misalignment.
Poorly aligned drives are often the cause of seal, rolling bearing
or coupling failure.
Alignment should be carried out carefully by specialist personnel in accordance with the Siemens operating instructions.
3
Kr
Depending on the direction of the effective shaft misalignment, a distinction is made between:
Kw
Ka
G_MD10_XX_00004
G_MD10_XX_00002
G_MD10_XX_00003
Radial misalignment
Angular misalignment
• Two-joint couplings – ARPEX and ZAPEX series
Two-joint couplings are always designed with an adapter. The
two joint levels are able to absorb axial and angular misalignment. Radial misalignment occurs via the gap between the
two joint levels and the angular displacement of the joint
levels. The permitted angular misalignment per joint level is
frequently about 0.5°. The permitted shaft misalignment of the
coupling can be adjusted via the length of the adapter. If there
are more than two joint levels, it is not possible to define the
position of the coupling parts relative to the axis of rotation.
(The less frequently used parallel-crank couplings are an
exception).
Kr
G_MD10_XX_00014
The couplings can be subdivided into the following groups:
• Single-joint couplings – N-EUPEX and RUPEX series
Couplings with flexible elements mainly made of elastomer
materials. Shaft misalignment results in deformation of the
elastomer elements. The elastomer elements can absorb shaft
misalignment as deformations in an axial, radial and angular
direction. The degree of permissible misalignment depends
on the coupling size, the speed of rotation and the type of
elastomer element.
Single-joint couplings do not require an adapter and are
therefore short versions.
Kr
Axial misalignment
G_MD10_XX_00005
Example: RUPEX coupling
Example: ARPEX coupling
Siemens D 81.8 · 04/2014
3/15
© Siemens AG 2014
System Components
Couplings
Siemens Integrated Drive Systems
■ Overview (continued)
Overload
3
Overload conditions are operating conditions that go beyond the
limit loads of the coupling. Overload conditions may occur under
non-standard operating conditions, e.g. drive blockage, short
circuit or supply fluctuations, as well as under standard operating conditions, e.g. when starting or braking. Particularly in the
case of high mass moments of inertia of the driven machine,
torques that are a multiple of the motor starting torque may
become effective during direct starting or star-delta starting.
Overload conditions may damage not only the coupling but also
the entire drive train. Overload conditions can frequently be prevented with special design measures. SIRIUS soft starters or
SINAMICS frequency converters are suitable for considerably
reducing starting torques of induction motors. If drive blockages
or overloads of the driven machine cannot be ruled out, torque
limiting SECUREX couplings can prevent damage to the drive
train.
Coupling behavior under overload conditions
Coupling behavior under overload where the torque is considerably above the limits of use of the coupling concerned is determined by the engineering design of the coupling series.
The ZAPEX, ARPEX, N-EUPEX and RUPEX coupling series can
withstand overloads until the breakage of metal parts.
These coupling series are designated as fail-safe. Coupling
types which can withstand overload, i.e. fail-safe types, are used
e.g. in crane systems. In case of coupling breakage due to overloads, the splintering metal parts may cause injury to persons
and property damage!
The N-EUPEX DS coupling series throws overload. The elastomer element of these couplings is irreparably damaged without
damage to metal parts when subjected to excessive overload.
These coupling series are designated as non-fail-safe. The
types that fail can be fitted with a fail-safe device. This component enables emergency operation, even after the rubber element of the coupling has been irreparably damaged.
Damping
On drives which are prone to torsional and bending vibrations,
measurements or calculations such as natural frequency calculations, torsional vibration simulation or bending vibration calculations are necessary for verifying safe dimensioning of the drive
train and preventing damage.
The drive train may, depending on complexity, be regarded as a
two-mass vibration-generating system or N-mass vibration-generating system. The vibration-generating masses are defined by
the rotating bodies and the couplings by the coupling stiffnesses
and shaft stiffnesses. The effect of torsional vibration excitations
on the behavior of the system is calculated.
Torsional vibration excitations may occur during the starting of
an induction motor, during a motor short circuit or in diesel engine drives. Bending vibrations may be critical if the coupling is
insufficiently balanced and/or at an operating speed close to the
critical speed.
The details needed for calculating the torsional vibration are
specified in the coupling catalog:
• Dynamic torsional stiffness
• Damping (specification of the damping coefficient ψ or Lehr's
damping D = ψ/4π)
• Mass moment of inertia of the coupling halves
Electrical insulation
A particularly efficient and economical measure for reducing
bearing currents is to use an electrically isolating coupling.
The range of couplings comprises suitable couplings in leakage-current-isolated versions for the various drive scenarios.
Version for potentially explosive atmospheres
Wherever a potentially explosive environment cannot be ruled
out, the machinery used must meet special conditions in order
to prevent the outbreak of fire as far as possible. Within the
European Union, Directive 94/9/EC applies to these applications. This directive, also called ATEX 95, harmonizes the individual states' legal requirements for explosion prevention and
clearly defines the procedure for testing and circulating
machines and parts.
Whether or not a machine is used in a potentially explosive
environment, the manufacturer is required under EC Machinery
Directive 98/37/EC to assess and as far as possible prevent
hazards which may arise from his product.
The operator has an obligation to ascertain whether an environment is potentially explosive. Details of this are laid down in
Directive 1999/92/EC, also known as ATEX 137. The manufacturer is responsible for ensuring that the product is safe as defined in the EC Machinery Directive and conforms to Directive
94/9/EC if the EX requirement is specified by the operator.
The drive train mostly comprises individual pieces of equipment
which are put together to form a subassembly. If the individual
pieces of equipment, such as motor, coupling, gear unit or
driven machine, conform to Directive 94/9/EC, the manufacturer
of the overall unit can limit the risk assessment to the additional
hazards which arise from the combination of different individual
pieces of equipment. The hazards which can arise from the
individual pieces of equipment are assessed by the relevant
suppliers.
The coupling series suitable for use in potentially explosive
environments are marked EX in Catalog MD 10.1.
FLENDER couplings are to be rated as components
according to the new EC Machinery Directive 2006/42/EC.
Therefore, Siemens does not issue a declaration of
incorporation for these products.
3/16
Siemens D 81.8 · 04/2014
© Siemens AG 2014
System Components
Couplings
Siemens Integrated Drive Systems
■ Overview (continued)
Assignment of coupling types to SIMOTICS FD motors
Motors
Air-cooled – enclosed version
Water-cooled
Air-cooled – open version
Self-ventilation
Forced-air cooling
Water-jacket cooling
Heat exchanger
Self-ventilation
Forced-air cooling
Cooling method IC411 Cooling method IC416 Cooling method IC71W Cooling method IC86W Cooling method IC01
Cooling method IC06
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
Conveyor belts,
paper machines,
rolling mills
Extruders, rolls,
winders
Propeller drives,
bow thrusters
Compressors,
fans
Lifting, holding,
closing gear
Paper, steel,
mining, cement
Marine, plastics,
textile, paper, steel
Marine, steel,
plastics
Energy,
steel
Cranes
RUPEX
ARPEX
ZAPEX
ARPEX
ZAPEX
ARPEX
ZAPEX
RUPEX
ARPEX
RUPEX
3
Applications
Pumps, fans,
compressors
Industry assignments
W&WW, energy,
chemicals, O&G
Coupling assignments
N-EUPEX
RUPEX
ARPEX
For further information on FLENDER couplings, see Catalog MD 10.1.
Siemens D 81.8 · 04/2014
3/17
© Siemens AG 2014
System Components
Couplings
Notes
3
3/18
Siemens D 81.8 · 04/2014
4
© Siemens AG 2014
Self-ventilated motors –
enclosed version
4/2
4/2
4/2
4/4
4/6
4/6
4/8
4/10
4/10
4/12
4/14
4/14
4/16
4/18
4/18
4/20
1LM1/1MM1 motors for
converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
Premium Efficiency
Line voltage 500 V, 50 Hz
High Efficiency
Premium Efficiency
Line voltage 690 V, 50 Hz
High Efficiency
Premium Efficiency
Line voltage 460 V, 60 Hz
High Efficiency
Premium Efficiency
Line voltage 575 V, 60 Hz
High Efficiency
Premium Efficiency
4/22
4/22
4/23
4/24
Dimensions
1LM1/1MM1 motors
Flanges
Terminal boxes
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
■ Selection and ordering data
4
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LM1/1MM1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V
3000 rpm, 4-pole
245
329
315
Δ
100.6 780
95.4
96.0
95.8
0.89
390
6.4
2.2
1■M1212-3AB11-1■■■
1■M1212-3AB31-1■■■
300
402
315
Δ
100.6 955
95.8
96.3
96.1
0.90
470
7.1
2.4
335
449
315
Δ
100.6 1066
95.8
96.3
95.9
0.90
530
7.5
2.5
1■M1212-3AB51-1■■■
385
516
315
Δ
100.5 1226
96.0
96.5
96.1
0.90
600
8.1
2.7
1■M1212-3AB71-1■■■
1■M1212-3BB51-1■■■
435
583
355
Δ
100.5 1385
95.8
96.3
95.9
0.89
690
6.8
2.4
455
610
355
Δ
100.6 1449
95.8
96.4
96.1
0.89
720
6.1
2.2
1■M1212-3BB71-1■■■
1500 rpm, 4-pole
245
329
315
Δ
50.5
1560
94.4
95.3
95.3
0.87
400
7.1
2.6
1■M1212-3AB11-2■■■
315
422
315
Δ
50.5
2006
95.0
95.7
95.7
0.87
510
8.1
3.0
1■M1212-3AB31-2■■■
345
463
315
Δ
50.5
2197
95.0
95.8
95.8
0.89
550
8.4
3.0
1■M1212-3AB51-2■■■
395
530
315
Δ
50.5
2515
95.2
96.0
96.0
0.90
620
8.4
2.9
1■M1212-3AB71-2■■■
450
603
355
Δ
50.5
2865
95.1
95.9
95.9
0.89
720
7.1
2.7
1■M1212-3BB51-2■■■
500
671
355
Δ
50.4
3184
95.3
96.1
96.0
0.88
800
7.9
3.0
1■M1212-3BB71-2■■■
1000 rpm, 6-pole
190
255
315
Δ
50.4
1815
94.7
95.5
95.4
0.79
340
8.4
2.7
1■M1212-3AC11-3■■■
235
315
315
Δ
50.4
2245
94.9
95.7
95.7
0.81
410
8.5
2.7
1■M1212-3AC31-3■■■
270
362
315
Δ
50.4
2579
95.1
95.7
95.8
0.83
460
8.4
2.6
1■M1212-3AC51-3■■■
1■M1212-3AC71-3■■■
295
396
315
Δ
50.4
2818
95.2
95.7
95.9
0.82
520
8.9
2.6
355
476
355
Δ
50.3
3391
95.0
95.7
95.5
0.85
590
9.7
2.9
1■M1212-3BC51-3■■■
395
530
355
Δ
50.3
3772
95.2
95.9
95.5
0.83
670
10.9
2.6
1■M1212-3BC71-3■■■
750 rpm, 6-pole
145
194
315
Δ
37.9
1847
93.9
94.8
94.8
0.77
270
8.2
2.9
1■M1212-3AC11-4■■■
185
248
315
Δ
37.9
2356
94.2
95.1
95.2
0.80
330
8.2
2.8
1■M1212-3AC31-4■■■
210
282
315
Δ
37.9
2675
94.3
95.3
95.4
0.83
360
7.9
2.6
1■M1212-3AC51-4■■■
235
315
315
Δ
37.9
2994
94.4
95.4
95.5
0.83
405
7.8
2.5
1■M1212-3AC71-4■■■
265
355
355
Δ
37.8
3376
94.3
95.3
95.3
0.86
440
9.0
2.9
1■M1212-3BC51-4■■■
300
402
355
Δ
37.8
3821
94.5
95.4
95.4
0.86
495
9.2
2.6
1■M1212-3BC71-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G120P, SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V
3000 rpm, 4-pole
235
315
315
Δ
100.6 748
95.4
96.0
95.7
0.88
425
6.5
2.2
1■M1222-3AB11-1■■■
1■M1222-3AB31-1■■■
300
402
315
Δ
100.6 955
95.8
96.4
96.1
0.90
530
7.4
2.5
325
436
315
Δ
100.5 1035
95.9
96.3
95.9
0.90
570
8.5
2.8
1■M1222-3AB51-1■■■
350
469
315
Δ
100.6 1114
95.8
96.3
96.1
0.91
610
7.0
2.3
1■M1222-3AB71-1■■■
420
563
355
Δ
100.4 1337
95.8
96.2
95.7
0.88
750
8.1
2.9
1■M1222-3BB51-1■■■
445
597
355
Δ
100.5 1417
95.8
96.4
96.0
0.89
790
7.2
2.6
1■M1222-3BB71-1■■■
1500 rpm, 4-pole
250
335
315
Δ
50.5
1592
94.6
95.4
95.3
0.85
470
7.6
2.9
1■M1222-3AB11-2■■■
315
422
315
Δ
50.5
2005
94.9
95.7
95.7
0.88
570
8.0
2.9
1■M1222-3AB31-2■■■
345
463
315
Δ
50.5
2197
95.1
95.8
95.8
0.88
620
8.5
3.1
1■M1222-3AB51-2■■■
400
536
315
Δ
50.5
2547
95.2
96.0
96.0
0.89
710
8.6
2.9
1■M1222-3AB71-2■■■
455
610
355
Δ
50.4
2897
95.1
95.9
95.9
0.88
820
7.3
2.8
1■M1222-3BB51-2■■■
510
684
355
Δ
50.4
3247
95.4
96.2
96.0
0.87
930
8.3
3.0
1■M1222-3BB71-2■■■
1000 rpm, 6-pole
190
255
315
Δ
50.4
1815
94.7
95.5
95.4
0.80
380
8.1
2.6
1■M1222-3AC11-3■■■
235
315
315
Δ
50.4
2245
95.0
95.7
95.7
0.81
460
8.6
2.8
1■M1222-3AC31-3■■■
270
362
315
Δ
50.4
2579
95.1
95.7
95.8
0.82
520
8.7
2.8
1■M1222-3AC51-3■■■
1■M1222-3AC71-3■■■
300
402
315
Δ
50.4
2865
95.2
95.7
96.0
0.84
570
8.4
2.6
355
476
355
Δ
50.3
3391
95.1
95.7
95.5
0.83
680
10.4
2.9
1■M1222-3BC51-3■■■
390
523
355
Δ
50.3
3725
95.2
95.9
95.6
0.84
740
10.4
2.7
1■M1222-3BC71-3■■■
750 rpm, 6-pole
150
201
315
Δ
37.9
1910
94.1
95.0
94.9
0.77
310
8.2
2.9
1■M1222-3AC11-4■■■
180
241
315
Δ
37.9
2292
94.3
95.2
95.1
0.77
375
8.6
3.1
1■M1222-3AC31-4■■■
210
282
315
Δ
37.9
2675
94.4
95.3
95.3
0.81
415
8.3
2.8
1■M1222-3AC51-4■■■
230
308
315
Δ
37.9
2930
94.4
95.4
95.5
0.83
440
8.0
2.5
1■M1222-3AC71-4■■■
270
362
355
Δ
37.9
3439
94.3
95.3
95.3
0.86
500
8.8
2.9
1■M1222-3BC51-4■■■
300
402
355
Δ
37.8
3821
94.5
95.4
95.4
0.86
560
9.3
2.6
1■M1222-3BC71-4■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC71-4■■■
Prated
4/2
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.M1212-3AB11-1...
1.M1212-3AB31-1...
1.M1212-3AB51-1...
1.M1212-3AB71-1...
1.M1212-3BB51-1...
1.M1212-3BB71-1...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
477
477
590
725
725
725
1.M1212-3AB11-2...
1.M1212-3AB31-2...
1.M1212-3AB51-2...
1.M1212-3AB71-2...
1.M1212-3BB51-2...
1.M1212-3BB71-2...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
477
590
590
725
725
820
1.M1212-3AC11-3...
1.M1212-3AC31-3...
1.M1212-3AC51-3...
1.M1212-3AC71-3...
1.M1212-3BC51-3...
1.M1212-3BC71-3...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-7LE33-8AA3
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
370
477
477
590
590
725
1.M1212-3AC11-4...
1.M1212-3AC31-4...
1.M1212-3AC51-4...
1.M1212-3AC71-4...
1.M1212-3BC51-4...
1.M1212-3BC71-4...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LE33-1AA3
6SL3710-7LE33-8AA3
6SL3710-7LE33-8AA3
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
302
370
370
477
477
590
1.M1222-3AB11-1...
1.M1222-3AB31-1...
1.M1222-3AB51-1...
1.M1222-3AB71-1...
1.M1222-3BB51-1...
1.M1222-3BB71-1...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1PE34-6AA0
6SL3710-1PE35-8AA0
6SL3710-1PE35-8AA0
6SL3710-1PE36-6AA0
6SL3710-1GE38-4AA3
6SL3710-1GE38-4AA3
450
570
570
640
820
820
1.M1222-3AB11-2...
1.M1222-3AB31-2...
1.M1222-3AB51-2...
1.M1222-3AB71-2...
1.M1222-3BB51-2...
1.M1222-3BB71-2...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1PE35-8AA0
6SL3710-1PE35-8AA0
6SL3370-1PE36-6AA0
6SL3710-1PE37-4AA0
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
570
570
640
710
820
960
1.M1222-3AC11-3...
1.M1222-3AC31-3...
1.M1222-3AC51-3...
1.M1222-3AC71-3...
1.M1222-3BC51-3...
1.M1222-3BC71-3...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1PE34-6AA0
6SL3710-1PE35-8AA0
6SL3710-1PE35-8AA0
6SL3710-1PE35-8AA0
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
450
570
570
570
725
820
1.M1222-3AC11-4...
1.M1222-3AC31-4...
1.M1222-3AC51-4...
1.M1222-3AC71-4...
1.M1222-3BC51-4...
1.M1222-3BC71-4...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1PE33-7AA0
6SL3710-1PE34-6AA0
6SL3710-1PE34-6AA0
6SL3710-1PE34-6AA0
6SL3710-1PE35-8AA0
6SL3710-1PE35-8AA0
360
450
450
450
570
570
Siemens D 81.8 · 04/2014
4
4/3
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LM1/1MM1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V
1500 rpm, 4-pole
4
175
235
315
Δ
50.4
1114
95.2
95.9
95.7
0.83
300
9.5
3.7
1■M1213-3AB11-2■■■
255
342
315
Δ
50.4
1625
95.5
96.2
96.1
0.85
425
9.7
3.7
1■M1213-3AB31-2■■■
320
429
315
Δ
50.4
2038
95.2
96.0
95.9
0.88
510
9.1
3.2
1■M1213-3AB51-2■■■
410
550
315
Δ
50.5
2610
95.2
96.0
96.1
0.90
640
8.2
2.8
1■M1213-3AB71-2■■■
465
624
355
Δ
50.5
2961
95.2
96.1
96.2
0.89
740
6.9
2.6
1■M1213-3BB51-2■■■
510
684
355
Δ
50.4
3247
95.5
96.3
96.3
0.88
820
7.7
3.0
1■M1213-3BB71-2■■■
1000 rpm, 6-pole
185
248
315
Δ
50.4
1767
94.8
95.7
95.6
0.79
330
8.6
2.8
1■M1213-3AC11-3■■■
240
322
315
Δ
50.4
2293
95.0
95.9
95.9
0.81
420
8.2
2.7
1■M1213-3AC31-3■■■
275
369
315
Δ
50.4
2627
95.1
96.0
96.0
0.83
470
8.1
2.6
1■M1213-3AC51-3■■■
305
409
315
Δ
50.4
2913
95.3
96.1
96.1
0.82
530
8.7
2.5
1■M1213-3AC71-3■■■
380
510
355
Δ
50.4
3630
95.2
96.1
96.1
0.85
630
9.1
2.7
1■M1213-3BC51-3■■■
420
563
355
Δ
50.3
4011
95.5
96.3
96.1
0.82
720
10.1
2.5
1■M1213-3BC71-3■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G120P, SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V
1500 rpm, 4-pole
185
248
315
Δ
50.4
1179
95.3
95.9
95.7
0.81
360
9.9
3.9
1■M1223-3AB11-2■■■
255
342
315
Δ
50.4
1623
95.5
96.2
96.1
0.85
475
9.6
3.6
1■M1223-3AB31-2■■■
335
449
315
Δ
50.5
2133
95.2
96.0
96.0
0.88
600
8.7
3.1
1■M1223-3AB51-2■■■
405
543
315
Δ
50.5
2579
95.2
96.1
96.1
0.89
720
8.5
2.9
1■M1223-3AB71-2■■■
470
630
355
Δ
50.5
2993
95.2
96.1
96.2
0.88
840
7.1
2.7
1■M1223-3BB51-2■■■
530
711
355
Δ
50.4
3375
95.6
96.4
96.4
0.87
960
8.1
2.9
1■M1223-3BB71-2■■■
1000 rpm, 6-pole
180
241
315
Δ
50.4
1720
94.8
95.7
95.6
0.79
360
8.5
2.8
1■M1223-3AC11-3■■■
240
322
315
Δ
50.4
2293
95.0
95.9
95.9
0.81
470
8.4
2.7
1■M1223-3AC31-3■■■
275
369
315
Δ
50.4
2627
95.1
96.0
96.0
0.82
530
8.5
2.7
1■M1223-3AC51-3■■■
310
416
315
Δ
50.4
2961
95.2
96.1
96.2
0.83
590
8.1
2.5
1■M1223-3AC71-3■■■
375
503
355
Δ
50.3
3582
95.4
96.2
96.0
0.83
710
9.9
2.8
1■M1223-3BC51-3■■■
415
557
355
Δ
50.3
3964
95.5
96.3
96.1
0.84
780
9.8
2.5
1■M1223-3BC71-3■■■
For versions, see Article No. supplements and special versions
4/4
Siemens D 81.8 · 04/2014
1■M1223-3AC71-3■■■
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.M1213-3AB11-2...
1260
1310
3.5
79
94
3000
1XB7 730
6SL3710-7LE33-1AA3
302
1.M1213-3AB31-2...
1440
1490
4.4
79
94
3000
1XB7 731
6SL3710-7LE35-0AA3
477
1.M1213-3AB51-2...
1620
1670
5.1
79
94
2500
1XB7 731
6SL3710-7LE36-1AA3
590
1.M1213-3AB71-2...
1780
1830
5.9
79
94
2500
1XB7 740
6SL3710-7LE37-5AA3
725
1.M1213-3BB51-2...
2220
2280
8.4
79
95
2200
1XB7 740
6SL3710-7LE38-4AA3
820
1.M1213-3BB71-2...
2350
2410
9
79
95
2200
1XB7 740
6SL3710-7LE38-4AA3
820
1.M1213-3AC11-3...
1290
1340
5.9
79
94
2500
1XB7 730
6SL3710-7LE33-8AA3
370
1.M1213-3AC31-3...
1460
1510
7.3
79
94
2500
1XB7 731
6SL3710-7LE35-0AA3
477
1.M1213-3AC51-3...
1650
1700
8.3
79
94
2500
1XB7 731
6SL3710-7LE35-0AA3
477
1.M1213-3AC71-3...
1750
1800
9.1
79
94
2500
1XB7 731
6SL3710-7LE36-1AA3
590
1.M1213-3BC51-3...
2220
2270
14.6
79
95
2200
1XB7 740
6SL3710-7LE37-5AA3
725
1.M1213-3BC71-3...
2370
2420
16.1
79
95
2200
1XB7 740
6SL3710-7LE37-5AA3
725
1.M1223-3AB11-2...
1260
1310
3.5
79
94
3000
1XB7 731
6SL3710-1PE33-7AA0
360
1.M1223-3AB31-2...
1440
1490
4.4
79
94
3000
1XB7 731
6SL3710-1PE35-8AA0
570
1.M1223-3AB51-2...
1620
1670
5.1
79
94
2500
1XB7 740
6SL3370-1PE36-6AA0
640
1.M1223-3AB71-2...
1780
1830
5.9
79
94
2500
1XB7 740
6SL3710-1GE37-5AA3
725
1.M1223-3BB51-2...
2220
2280
8.4
79
95
2200
1XB7 740
6SL3710-1GE41-0AA3
960
1.M1223-3BB71-2...
2350
2410
9
79
95
2200
1XB7 740
6SL3710-1GE41-0AA3
960
1.M1223-3AC11-3...
1290
1340
5.9
79
94
2500
1XB7 731
6SL3710-1PE33-7AA0
360
1.M1223-3AC31-3...
1460
1510
7.3
79
94
2500
1XB7 731
6SL3710-1PE35-8AA0
570
1.M1223-3AC51-3...
1650
1700
8.3
79
94
2500
1XB7 731
6SL3710-1PE35-8AA0
570
1.M1223-3AC71-3...
1750
1800
9.1
79
94
2500
1XB7 731
6SL3370-1PE36-6AA0
640
1.M1223-3BC51-3...
2220
2270
14.6
79
95
2200
1XB7 740
6SL3710-1PE37-4AA0
710
1.M1223-3BC71-3...
2370
2420
16.1
79
95
2200
1XB7 740
6SL3710-1GE38-4AA3
820
Siemens D 81.8 · 04/2014
4
4/5
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency
■ Selection and ordering data
4
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LM1/1MM1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V
3000 rpm, 4-pole
225
302
315
Δ
100.6 716
95.4
95.9
95.6
0.88
295
7.2
2.4
1■M1212-3AB12-1■■■
1■M1212-3AB32-1■■■
285
382
315
Δ
100.5 907
95.8
96.3
95.9
0.89
370
8.8
3.0
305
409
315
Δ
100.4 971
95.8
96.1
95.7
0.89
395
9.5
3.2
1■M1212-3AB52-1■■■
335
449
315
Δ
100.5 1067
95.7
96.3
95.9
0.91
425
7.8
2.6
1■M1212-3AB72-1■■■
1■M1212-3BB52-1■■■
410
550
355
Δ
100.4 1305
95.7
96.2
95.7
0.89
530
8.0
2.8
435
583
355
Δ
100.5 1385
95.7
96.3
95.9
0.89
560
7.1
2.5
1■M1212-3BB72-1■■■
1500 rpm, 4-pole
225
302
315
Δ
50.5
1433
94.3
95.2
95.1
0.87
300
7.6
2.8
1■M1212-3AB12-2■■■
285
382
315
Δ
50.5
1815
94.7
95.5
95.6
0.89
370
8.1
2.9
1■M1212-3AB32-2■■■
320
429
315
Δ
50.4
2037
95.0
95.8
95.7
0.88
420
9.1
3.3
1■M1212-3AB52-2■■■
380
510
315
Δ
50.4
2421
95.3
96.0
95.9
0.87
510
10.0
3.1
1■M1212-3AB72-2■■■
435
583
355
Δ
50.4
2770
95.2
95.9
95.7
0.87
580
8.6
3.3
1■M1212-3BB52-2■■■
480
644
355
Δ
50.4
3058
95.4
96.0
95.8
0.86
650
9.2
3.2
1■M1212-3BB72-2■■■
1000 rpm, 6-pole
180
241
315
Δ
50.4
1719
94.7
95.4
95.3
0.79
265
8.8
2.9
1■M1212-3AC12-3■■■
210
282
315
Δ
50.4
2006
94.9
95.6
95.5
0.80
305
9.3
3.0
1■M1212-3AC32-3■■■
245
329
315
Δ
50.4
2340
94.9
95.7
95.7
0.83
340
8.8
2.8
1■M1212-3AC52-3■■■
1■M1212-3AC72-3■■■
270
362
315
Δ
50.4
2579
95.0
95.7
95.7
0.83
375
9.0
2.8
325
436
355
Δ
50.3
3104
94.9
95.6
95.3
0.84
450
10.6
3.2
1■M1212-3BC52-3■■■
360
483
355
Δ
50.3
3438
95.1
95.7
95.3
0.83
500
11.3
2.9
1■M1212-3BC72-3■■■
750 rpm, 6-pole
130
174
315
Δ
37.9
1656
93.9
94.7
94.5
0.75
205
9.0
3.3
1■M1212-3AC12-4■■■
165
221
315
Δ
37.9
2102
94.1
95.0
94.9
0.78
245
9.1
3.1
1■M1212-3AC32-4■■■
190
255
315
Δ
37.9
2420
94.1
95.1
95.2
0.83
265
8.4
2.8
1■M1212-3AC52-4■■■
210
282
315
Δ
37.9
2674
94.3
95.2
95.3
0.82
300
8.7
2.8
1■M1212-3AC72-4■■■
250
335
355
Δ
37.8
3184
94.4
95.2
95.0
0.83
350
10.4
3.1
1■M1212-3BC52-4■■■
270
362
355
Δ
37.8
3438
94.4
95.3
95.2
0.85
370
9.7
2.9
1■M1212-3BC72-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V
3000 rpm, 4-pole
250
335
315
Δ
100.6 796
95.5
96.1
95.8
0.88
355
6.6
2.2
1■M1222-3AB12-1■■■
1■M1222-3AB32-1■■■
305
409
315
Δ
100.6 971
95.8
96.3
96.1
0.90
425
7.0
2.3
330
443
315
Δ
100.6 1051
95.8
96.3
95.9
0.90
460
7.5
2.5
1■M1222-3AB52-1■■■
375
503
315
Δ
100.5 1194
95.9
96.4
96.1
0.91
510
7.9
2.6
1■M1222-3AB72-1■■■
420
563
355
Δ
100.5 1337
95.7
96.3
95.9
0.89
590
6.6
2.4
1■M1222-3BB52-1■■■
460
617
355
Δ
100.4 1464
95.9
96.4
95.9
0.89
640
7.8
2.8
1■M1222-3BB72-1■■■
1500 rpm, 4-pole
240
322
315
Δ
50.6
1528
94.4
95.3
95.3
0.87
350
6.9
2.6
1■M1222-3AB12-2■■■
320
429
315
Δ
50.5
2037
95.0
95.8
95.7
0.87
460
8.4
3.1
1■M1222-3AB32-2■■■
350
469
315
Δ
50.5
2228
95.1
95.9
95.8
0.88
500
8.5
3.1
1■M1222-3AB52-2■■■
395
530
315
Δ
50.5
2515
95.2
96.0
96.0
0.90
550
8.5
2.9
1■M1222-3AB72-2■■■
480
644
355
Δ
50.4
3056
95.3
96.1
95.9
0.87
690
8.5
3.2
1■M1222-3BB52-2■■■
505
677
355
Δ
50.4
3215
95.3
96.1
96.0
0.89
710
7.7
2.9
1■M1222-3BB72-2■■■
1000 rpm, 6-pole
185
248
315
Δ
50.5
1768
94.6
95.5
95.4
0.81
290
7.9
2.5
1■M1222-3AC12-3■■■
230
308
315
Δ
50.4
2197
95.0
95.7
95.6
0.80
360
8.9
2.9
1■M1222-3AC32-3■■■
270
362
315
Δ
50.4
2579
95.0
95.7
95.8
0.83
410
8.4
2.7
1■M1222-3AC52-3■■■
1■M1222-3AC72-3■■■
300
402
315
Δ
50.4
2865
95.2
95.7
95.9
0.82
460
8.7
2.6
360
483
355
Δ
50.3
3439
95.0
95.7
95.5
0.85
530
9.3
2.9
1■M1222-3BC52-3■■■
400
536
355
Δ
50.3
3821
95.2
95.9
95.6
0.85
590
10.2
2.6
1■M1222-3BC72-3■■■
750 rpm, 6-pole
145
194
315
Δ
37.9
1847
93.9
94.9
94.9
0.78
235
8.2
2.8
1■M1222-3AC12-4■■■
185
248
315
Δ
37.9
2356
94.2
95.1
95.2
0.80
290
8.2
2.8
1■M1222-3AC32-4■■■
210
282
315
Δ
37.9
2675
94.2
95.2
95.4
0.83
320
7.6
2.5
1■M1222-3AC52-4■■■
230
308
315
Δ
37.9
2930
94.2
95.3
95.5
0.84
345
7.6
2.5
1■M1222-3AC72-4■■■
270
362
355
Δ
37.8
3439
94.4
95.3
95.3
0.85
400
9.2
2.9
1■M1222-3BC52-4■■■
300
402
355
Δ
37.8
3821
94.5
95.4
95.4
0.86
440
9.3
2.6
1■M1222-3BC72-4■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC72-4■■■
Prated
4/6
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.M1212-3AB12-1...
1.M1212-3AB32-1...
1.M1212-3AB52-1...
1.M1212-3AB72-1...
1.M1212-3BB52-1...
1.M1212-3BB72-1...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
320
400
400
452
560
560
1.M1212-3AB12-2...
1.M1212-3AB32-2...
1.M1212-3AB52-2...
1.M1212-3AB72-2...
1.M1212-3BB52-2...
1.M1212-3BB72-2...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
320
400
452
560
710
710
1.M1212-3AC12-3...
1.M1212-3AC32-3...
1.M1212-3AC52-3...
1.M1212-3AC72-3...
1.M1212-3BC52-3...
1.M1212-3BC72-3...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
320
320
400
400
452
560
1.M1212-3AC12-4...
1.M1212-3AC32-4...
1.M1212-3AC52-4...
1.M1212-3AC72-4...
1.M1212-3BC52-4...
1.M1212-3BC72-4...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
6SL3710-7LG32-2AA3
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
208
250
320
320
400
400
1.M1222-3AB12-1...
1.M1222-3AB32-1...
1.M1222-3AB52-1...
1.M1222-3AB72-1...
1.M1222-3BB52-1...
1.M1222-3BB72-1...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
370
477
477
590
590
725
1.M1222-3AB12-2...
1.M1222-3AB32-2...
1.M1222-3AB52-2...
1.M1222-3AB72-2...
1.M1222-3BB52-2...
1.M1222-3BB72-2...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
370
477
590
590
725
725
1.M1222-3AC12-3...
1.M1222-3AC32-3...
1.M1222-3AC52-3...
1.M1222-3AC72-3...
1.M1222-3BC52-3...
1.M1222-3BC72-3...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GE33-1AA3
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
302
370
477
477
590
590
1.M1222-3AC12-4...
1.M1222-3AC32-4...
1.M1222-3AC52-4...
1.M1222-3AC72-4...
1.M1222-3BC52-4...
1.M1222-3BC72-4...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-1GE32-6AA3
6SL3710-1GE33-1AA3
6SL3710-1GE33-8AA3
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
250
302
370
370
477
477
Siemens D 81.8 · 04/2014
4
4/7
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LM1/1MM1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V
1500 rpm, 4-pole
4
160
215
315
Δ
50.3
1020
95.2
95.8
95.6
0.82
225
10.2
4.0
1■M1213-3AB12-2■■■
230
308
315
Δ
50.4
1464
95.2
96.0
96.0
0.86
310
9.6
3.5
1■M1213-3AB32-2■■■
295
396
315
Δ
50.4
1878
95.1
96.0
95.8
0.87
390
9.7
3.5
1■M1213-3AB52-2■■■
390
523
315
Δ
50.4
2483
95.3
96.1
96.0
0.87
520
9.8
3.0
1■M1213-3AB72-2■■■
460
617
355
Δ
50.4
2928
95.3
96.2
96.1
0.87
610
8.1
3.2
1■M1213-3BB52-2■■■
505
677
355
Δ
50.4
3218
95.5
96.3
96.2
0.86
680
8.8
3.1
1■M1213-3BB72-2■■■
1000 rpm, 6-pole
165
221
315
Δ
50.4
1576
94.8
95.6
95.4
0.78
245
9.4
3.1
1■M1213-3AC12-3■■■
215
288
315
Δ
50.4
2054
95.0
95.8
95.7
0.80
310
9.1
3.0
1■M1213-3AC32-3■■■
250
335
315
Δ
50.4
2388
94.9
95.8
95.9
0.83
350
8.5
2.7
1■M1213-3AC52-3■■■
275
369
315
Δ
50.4
2627
95.1
95.9
96.0
0.83
385
8.7
2.8
1■M1213-3AC72-3■■■
345
463
355
Δ
50.3
3295
95.2
96.0
95.9
0.84
475
10.0
3.0
1■M1213-3BC52-3■■■
380
510
355
Δ
50.3
3629
95.4
96.1
96.0
0.82
540
10.4
2.7
1■M1213-3BC72-3■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V
1500 rpm, 4-pole
180
241
315
Δ
50.4
1146
95.1
95.9
95.8
0.85
265
9.1
3.4
1■M1223-3AB12-2■■■
260
349
315
Δ
50.4
1657
95.5
96.2
96.1
0.84
385
10.1
3.8
1■M1223-3AB32-2■■■
345
463
315
Δ
50.5
2197
95.2
96.0
96.0
0.88
490
8.7
3.1
1■M1223-3AB52-2■■■
405
543
315
Δ
50.5
2579
95.1
96.0
96.1
0.90
560
8.3
2.9
1■M1223-3AB72-2■■■
495
664
355
Δ
50.4
3152
95.5
96.3
96.3
0.86
720
8.1
3.1
1■M1223-3BB52-2■■■
520
697
355
Δ
50.4
3311
95.4
96.3
96.3
0.88
740
7.4
2.8
1■M1223-3BB72-2■■■
1000 rpm, 6-pole
170
228
315
Δ
50.4
1624
94.8
95.7
95.6
0.80
265
8.6
2.8
1■M1223-3AC12-3■■■
240
322
315
Δ
50.4
2292
95.0
95.9
95.9
0.80
375
8.5
2.8
1■M1223-3AC32-3■■■
275
369
315
Δ
50.4
2627
95.1
96.0
96.0
0.83
415
8.2
2.6
1■M1223-3AC52-3■■■
310
416
315
Δ
50.4
2961
95.2
96.1
96.1
0.82
475
8.4
2.5
1■M1223-3AC72-3■■■
375
503
355
Δ
50.4
3582
95.2
96.1
96.1
0.85
550
9.0
2.8
1■M1223-3BC52-3■■■
425
570
355
Δ
50.3
4059
95.4
96.2
96.2
0.84
630
9.5
2.4
1■M1223-3BC72-3■■■
For versions, see Article No. supplements and special versions
4/8
Siemens D 81.8 · 04/2014
1■M1223-3AC72-3■■■
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.M1213-3AB12-2...
1260
1310
3.5
79
94
3000
1XB7 730
6SL3710-7LG32-6AA3
250
1.M1213-3AB32-2...
1440
1490
4.4
79
94
3000
1XB7 730
6SL3710-7LG33-3AA3
320
1.M1213-3AB52-2...
1620
1670
5.1
79
94
2500
1XB7 731
6SL3710-7LG34-1AA3
400
1.M1213-3AB72-2...
1780
1830
5.9
79
94
2500
1XB7 731
6SL3710-7LG35-8AA3
560
1.M1213-3BB52-2...
2220
2280
8.4
79
95
2200
1XB7 740
6SL3710-7LG37-4AA3
710
1.M1213-3BB72-2...
2350
2410
9
79
95
2200
1XB7 740
6SL3710-7LG37-4AA3
710
1.M1213-3AC12-3...
1290
1340
5.9
79
94
2500
1XB7 730
6SL3710-7LG32-6AA3
250
1.M1213-3AC32-3...
1460
1510
7.3
79
94
2500
1XB7 730
6SL3710-7LG33-3AA3
320
1.M1213-3AC52-3...
1650
1700
8.3
79
94
2500
1XB7 730
6SL3710-7LG34-1AA3
400
1.M1213-3AC72-3...
1750
1800
9.1
79
94
2500
1XB7 731
6SL3710-7LG34-1AA3
400
1.M1213-3BC52-3...
2220
2270
14.6
79
95
2200
1XB7 731
6SL3710-7LG35-8AA3
560
1.M1213-3BC72-3...
2370
2420
16.1
79
95
2200
1XB7 731
6SL3710-7LG35-8AA3
560
1.M1223-3AB12-2...
1260
1310
3.5
79
94
3000
1XB7 730
6SL3710-1GE33-1AA3
302
1.M1223-3AB32-2...
1440
1490
4.4
79
94
3000
1XB7 731
6SL3710-1GE35-0AA3
477
1.M1223-3AB52-2...
1620
1670
5.1
79
94
2500
1XB7 731
6SL3710-1GE36-1AA3
590
1.M1223-3AB72-2...
1780
1830
5.9
79
94
2500
1XB7 731
6SL3710-1GE36-1AA3
590
1.M1223-3BB52-2...
2220
2280
8.4
79
95
2200
1XB7 740
6SL3710-1GE37-5AA3
725
1.M1223-3BB72-2...
2350
2410
9
79
95
2200
1XB7 740
6SL3710-1GE38-4AA3
820
1.M1223-3AC12-3...
1290
1340
5.9
79
94
2500
1XB7 730
6SL3710-1GE33-1AA3
302
1.M1223-3AC32-3...
1460
1510
7.3
79
94
2500
1XB7 731
6SL3710-1GE35-0AA3
477
1.M1223-3AC52-3...
1650
1700
8.3
79
94
2500
1XB7 731
6SL3710-1GE35-0AA3
477
1.M1223-3AC72-3...
1750
1800
9.1
79
94
2500
1XB7 731
6SL3710-1GE35-0AA3
477
1.M1223-3BC52-3...
2220
2270
14.6
79
95
2200
1XB7 731
6SL3710-1GE36-1AA3
590
1.M1223-3BC72-3...
2370
2420
16.1
79
95
2200
1XB7 740
6SL3710-1GE37-5AA3
725
Siemens D 81.8 · 04/2014
4
4/9
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency
■ Selection and ordering data
4
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LM1/1MM1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V
3000 rpm, 4-pole
220
295
315
Δ
100.5 701
95.4
95.9
95.5
0.88
205
7.3
2.5
1■M1212-3AB13-1■■■
1■M1212-3AB33-1■■■
290
389
315
Δ
100.5 923
95.8
96.2
95.9
0.89
270
8.1
2.7
315
422
315
Δ
100.4 1003
95.8
96.2
95.7
0.89
290
9.6
3.2
1■M1212-3AB53-1■■■
360
483
315
Δ
100.5 1146
95.9
96.3
95.9
0.90
330
9.1
3.0
1■M1212-3AB73-1■■■
1■M1212-3BB53-1■■■
425
570
355
Δ
100.5 1353
95.7
96.2
95.8
0.89
395
7.3
2.6
450
603
355
Δ
100.5 1433
95.7
96.3
96.0
0.89
415
6.5
2.3
1■M1212-3BB73-1■■■
1500 rpm, 4-pole
210
282
315
Δ
50.4
1337
94.5
95.2
95.1
0.85
205
8.3
3.1
1■M1212-3AB13-2■■■
290
389
315
Δ
50.4
1846
94.9
95.6
95.5
0.86
280
8.8
3.2
1■M1212-3AB33-2■■■
325
436
315
Δ
50.4
2069
95.1
95.8
95.7
0.87
310
9.4
3.4
1■M1212-3AB53-2■■■
370
496
315
Δ
50.4
2356
95.2
95.9
95.8
0.88
345
9.9
3.1
1■M1212-3AB73-2■■■
420
563
355
Δ
50.4
2674
95.2
95.9
95.7
0.87
400
8.3
3.3
1■M1212-3BB53-2■■■
470
630
355
Δ
50.4
2992
95.2
96.0
95.9
0.88
440
8.4
3.2
1■M1212-3BB73-2■■■
1000 rpm, 6-pole
160
215
315
Y
50.4
1528
94.7
95.4
95.1
0.78
170
9.5
3.1
1■M1212-3AC13-3■■■
200
268
315
Y
50.4
1910
94.9
95.6
95.4
0.80
205
9.7
3.1
1■M1212-3AC33-3■■■
245
329
315
Y
50.4
2340
95.0
95.7
95.7
0.82
245
8.9
2.8
1■M1212-3AC53-3■■■
1■M1212-3AC73-3■■■
275
369
315
Δ
50.4
2626
95.1
95.7
95.8
0.83
275
9.0
2.8
325
436
355
Δ
50.3
3104
94.9
95.6
95.3
0.84
320
10.4
3.2
1■M1212-3BC53-3■■■
360
483
355
Δ
50.3
3438
95.1
95.7
95.3
0.83
360
11.2
2.9
1■M1212-3BC73-3■■■
750 rpm, 6-pole
130
174
315
Y
37.9
1656
93.8
94.7
94.5
0.76
142
8.9
3.2
1■M1212-3AC13-4■■■
170
228
315
Y
37.9
2165
94.2
95.0
95.0
0.79
180
8.6
3.0
1■M1212-3AC33-4■■■
190
255
315
Δ
37.9
2420
94.2
95.1
95.2
0.82
192
8.5
2.8
1■M1212-3AC53-4■■■
205
275
315
Δ
37.9
2610
94.4
95.3
95.4
0.82
205
8.7
2.8
1■M1212-3AC73-4■■■
250
335
355
Y
37.8
3184
94.3
95.2
95.0
0.84
245
10.3
3.1
1■M1212-3BC53-4■■■
280
375
355
Δ
37.8
3565
94.5
95.3
95.2
0.84
275
10.5
2.8
1■M1212-3BC73-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V
3000 rpm, 4-pole
225
302
315
Δ
100.5 716
95.4
95.9
95.5
0.88
235
7.4
2.5
1■M1222-3AB13-1■■■
1■M1222-3AB33-1■■■
280
375
315
Δ
100.5 891
95.7
96.2
95.9
0.89
285
8.1
2.7
300
402
315
Δ
100.4 956
95.8
96.1
95.6
0.89
305
10.0
3.3
1■M1222-3AB53-1■■■
345
463
315
Δ
100.4 1098
95.9
96.3
95.9
0.90
350
9.6
3.2
1■M1222-3AB73-1■■■
385
516
355
Δ
100.4 1226
95.7
96.1
95.6
0.88
400
8.1
3.0
1■M1222-3BB53-1■■■
425
570
355
Δ
100.5 1353
95.7
96.3
95.9
0.89
435
7.0
2.5
1■M1222-3BB73-1■■■
1500 rpm, 4-pole
230
308
315
Δ
50.5
1465
94.4
95.2
95.2
0.86
245
7.7
2.9
1■M1222-3AB13-2■■■
290
389
315
Δ
50.5
1846
94.8
95.6
95.6
0.88
300
8.3
3.0
1■M1222-3AB33-2■■■
310
416
315
Δ
50.4
1974
95.0
95.7
95.6
0.88
320
9.3
3.3
1■M1222-3AB53-2■■■
375
503
315
Δ
50.4
2388
95.2
95.9
95.9
0.89
385
9.5
3.1
1■M1222-3AB73-2■■■
420
563
355
Δ
50.3
2676
95.3
95.9
95.7
0.85
450
9.4
3.7
1■M1222-3BB53-2■■■
460
617
355
Δ
50.4
2929
95.2
96.0
95.9
0.88
475
8.3
3.2
1■M1222-3BB73-2■■■
1000 rpm, 6-pole
170
228
315
Y
50.4
1624
94.6
95.3
95.2
0.79
198
8.9
2.9
1■M1222-3AC13-3■■■
210
282
315
Δ
50.4
2006
94.9
95.6
95.5
0.80
240
9.3
3.0
1■M1222-3AC33-3■■■
250
335
315
Δ
50.4
2388
95.0
95.7
95.7
0.83
275
8.9
2.8
1■M1222-3AC53-3■■■
1■M1222-3AC73-3■■■
270
362
315
Δ
50.4
2579
95.1
95.7
95.7
0.81
305
9.5
2.9
325
436
355
Δ
50.3
3104
94.9
95.6
95.3
0.85
350
10.3
3.2
1■M1222-3BC53-3■■■
350
469
355
Δ
50.3
3343
95.1
95.7
95.3
0.83
385
11.6
3.0
1■M1222-3BC73-3■■■
750 rpm, 6-pole
130
174
315
Y
37.9
1656
93.8
94.7
94.6
0.78
154
8.5
3.0
1■M1222-3AC13-4■■■
170
228
315
Δ
37.9
2165
94.3
95.1
94.9
0.77
205
8.9
3.2
1■M1222-3AC33-4■■■
195
261
315
Δ
37.9
2483
94.2
95.1
95.2
0.81
220
8.5
2.9
1■M1222-3AC53-4■■■
210
282
315
Δ
37.9
2675
94.2
95.2
95.3
0.83
230
8.4
2.8
1■M1222-3AC73-4■■■
250
335
355
Δ
37.8
3184
94.4
95.2
95.0
0.83
275
10.3
3.1
1■M1222-3BC53-4■■■
270
362
355
Δ
37.8
3439
94.4
95.3
95.1
0.85
290
10.3
2.9
1■M1222-3BC73-4■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC73-4■■■
Prated
4/10
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.M1212-3AB13-1...
1.M1212-3AB33-1...
1.M1212-3AB53-1...
1.M1212-3AB73-1...
1.M1212-3BB53-1...
1.M1212-3BB73-1...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-7LG32-2AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
208
320
320
400
400
452
1.M1212-3AB13-2...
1.M1212-3AB33-2...
1.M1212-3AB53-2...
1.M1212-3AB73-2...
1.M1212-3BB53-2...
1.M1212-3BB73-2...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-7LG32-2AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG34-7AA3
208
320
320
400
452
452
1.M1212-3AC13-3...
1.M1212-3AC33-3...
1.M1212-3AC53-3...
1.M1212-3AC73-3...
1.M1212-3BC53-3...
1.M1212-3BC73-3...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
6SL3710-7LG31-8AA3
6SL3710-7LG32-2AA3
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
170
208
250
320
320
400
1.M1212-3AC13-4...
1.M1212-3AC33-4...
1.M1212-3AC53-4...
1.M1212-3AC73-4...
1.M1212-3BC53-4...
1.M1212-3BC73-4...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
6SL3710-7LG31-5AA3
6SL3710-7LG32-2AA3
6SL3710-7LG32-2AA3
6SL3710-7LG32-2AA3
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
142
208
208
208
250
320
1.M1222-3AB13-1...
1.M1222-3AB33-1...
1.M1222-3AB53-1...
1.M1222-3AB73-1...
1.M1222-3BB53-1...
1.M1222-3BB73-1...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-1GH32-6AA3
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
250
320
320
400
400
452
1.M1222-3AB13-2...
1.M1222-3AB33-2...
1.M1222-3AB53-2...
1.M1222-3AB73-2...
1.M1222-3BB53-2...
1.M1222-3BB73-2...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GH32-6AA3
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
250
320
320
400
452
560
1.M1222-3AC13-3...
1.M1222-3AC33-3...
1.M1222-3AC53-3...
1.M1222-3AC73-3...
1.M1222-3BC53-3...
1.M1222-3BC73-3...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
6SL3710-1GH32-2AA3
6SL3710-1GH32-6AA3
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
208
250
320
320
400
400
1.M1222-3AC13-4...
1.M1222-3AC33-4...
1.M1222-3AC53-4...
1.M1222-3AC73-4...
1.M1222-3BC53-4...
1.M1222-3BC73-4...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
6SL3710-1GH31-8AA3
6SL3710-1GH32-2AA3
6SL3710-1GH32-6AA3
6SL3710-1GH32-6AA3
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
171
208
250
250
320
320
Siemens D 81.8 · 04/2014
4
4/11
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LM1/1MM1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V
1500 rpm, 4-pole
4
155
208
315
Δ
50.3
987
95.2
95.8
95.5
0.80
160
10.7
4.3
1■M1213-3AB13-2■■■
230
308
315
Δ
50.3
1465
95.4
96.1
95.9
0.83
230
10.7
4.1
1■M1213-3AB33-2■■■
325
436
315
Δ
50.4
2069
95.1
96.0
95.8
0.87
310
9.2
3.4
1■M1213-3AB53-2■■■
380
510
315
Δ
50.4
2419
95.3
96.0
96.0
0.88
355
9.6
3.1
1■M1213-3AB73-2■■■
455
610
355
Δ
50.4
2897
95.3
96.1
96.1
0.87
430
7.7
3.0
1■M1213-3BB53-2■■■
480
644
355
Δ
50.4
3056
95.4
96.2
96.2
0.88
450
8.2
3.2
1■M1213-3BB73-2■■■
1000 rpm, 6-pole
155
208
315
Y
50.3
1481
94.8
95.5
95.3
0.77
166
9.7
3.2
1■M1213-3AC13-3■■■
200
268
315
Y
50.4
1910
95.0
95.8
95.7
0.80
205
9.6
3.1
1■M1213-3AC33-3■■■
250
335
315
Y
50.4
2388
95.0
95.9
95.9
0.82
250
8.7
2.8
1■M1213-3AC53-3■■■
285
382
315
Δ
50.4
2722
95.1
96.0
96.0
0.83
285
8.6
2.7
1■M1213-3AC73-3■■■
345
463
355
Δ
50.3
3295
95.2
96.0
95.9
0.84
340
9.8
3.0
1■M1213-3BC53-3■■■
385
516
355
Δ
50.3
3677
95.4
96.1
96.0
0.82
385
10.5
2.7
1■M1213-3BC73-3■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V
1500 rpm, 4-pole
145
194
315
Δ
50.3
924
95.3
95.8
95.5
0.79
168
11.1
4.5
1■M1223-3AB13-2■■■
235
315
315
Δ
50.4
1496
95.3
96.1
96.0
0.85
250
10.0
3.7
1■M1223-3AB33-2■■■
285
382
315
Δ
50.4
1815
95.2
96.0
95.8
0.87
300
9.9
3.6
1■M1223-3AB53-2■■■
380
510
315
Δ
50.4
2419
95.2
96.0
96.0
0.89
390
9.3
3.1
1■M1223-3AB73-2■■■
455
610
355
Δ
50.4
2900
95.5
96.2
96.1
0.85
485
8.7
3.4
1■M1223-3BB53-2■■■
480
644
355
Δ
50.4
3056
95.4
96.2
96.2
0.88
495
8.0
3.1
1■M1223-3BB73-2■■■
1000 rpm, 6-pole
155
208
315
Y
50.4
1480
94.8
95.5
95.4
0.77
184
9.5
3.2
1■M1223-3AC13-3■■■
210
282
315
Δ
50.4
2006
95.0
95.8
95.7
0.80
240
9.2
3.0
1■M1223-3AC33-3■■■
260
349
315
Δ
50.4
2484
95.0
95.9
95.9
0.83
285
8.5
2.7
1■M1223-3AC53-3■■■
280
375
315
Δ
50.4
2674
95.2
96.0
95.9
0.81
315
9.1
2.8
1■M1223-3AC73-3■■■
340
456
355
Δ
50.3
3248
95.2
96.0
95.9
0.84
370
9.7
3.0
1■M1223-3BC53-3■■■
360
483
355
Δ
50.3
3438
95.4
96.1
95.9
0.82
400
11.1
2.9
1■M1223-3BC73-3■■■
For versions, see Article No. supplements and special versions
4/12
Siemens D 81.8 · 04/2014
1■M1223-3AC73-3■■■
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.M1213-3AB13-2...
1260
1310
3.5
79
94
3000
1XB7 730
6SL3710-7LG31-8AA3
170
1.M1213-3AB33-2...
1440
1490
4.4
79
94
3000
1XB7 730
6SL3710-7LG32-6AA3
250
1.M1213-3AB53-2...
1620
1670
5.1
79
94
2500
1XB7 730
6SL3710-7LG33-3AA3
320
1.M1213-3AB73-2...
1780
1830
5.9
79
94
2500
1XB7 731
6SL3710-7LG34-1AA3
400
1.M1213-3BB53-2...
2220
2280
8.4
79
95
2200
1XB7 731
6SL3710-7LG34-7AA3
452
1.M1213-3BB73-2...
2350
2410
9
79
95
2200
1XB7 731
6SL3710-7LG34-7AA3
452
1.M1213-3AC13-3...
1290
1340
5.9
79
94
2500
1XB7 730
6SL3710-7LG31-8AA3
170
1.M1213-3AC33-3...
1460
1510
7.3
79
94
2500
1XB7 730
6SL3710-7LG32-2AA3
208
1.M1213-3AC53-3...
1650
1700
8.3
79
94
2500
1XB7 730
6SL3710-7LG32-6AA3
250
1.M1213-3AC73-3...
1750
1800
9.1
79
94
2500
1XB7 730
6SL3710-7LG33-3AA3
320
1.M1213-3BC53-3...
2220
2270
14.6
79
95
2200
1XB7 730
6SL3710-7LG34-1AA3
400
1.M1213-3BC73-3...
2370
2420
16.1
79
95
2200
1XB7 731
6SL3710-7LG34-1AA3
400
1.M1223-3AB13-2...
1260
1310
3.5
79
94
3000
1XB7 730
6SL3710-1GH31-8AA3
171
1.M1223-3AB33-2...
1440
1490
4.4
79
94
3000
1XB7 730
6SL3710-1GH32-6AA3
250
1.M1223-3AB53-2...
1620
1670
5.1
79
94
2500
1XB7 730
6SL3710-1GH33-3AA3
320
1.M1223-3AB73-2...
1780
1830
5.9
79
94
2500
1XB7 731
6SL3710-1GH34-1AA3
400
1.M1223-3BB53-2...
2220
2280
8.4
79
95
2200
1XB7 731
6SL3710-1GH35-8AA3
560
1.M1223-3BB73-2...
2350
2410
9
79
95
2200
1XB7 731
6SL3710-1GH35-8AA3
560
1.M1223-3AC13-3...
1290
1340
5.9
79
94
2500
1XB7 730
6SL3710-1GH32-2AA3
208
1.M1223-3AC33-3...
1460
1510
7.3
79
94
2500
1XB7 730
6SL3710-1GH32-6AA3
250
1.M1223-3AC53-3...
1650
1700
8.3
79
94
2500
1XB7 730
6SL3710-1GH33-3AA3
320
1.M1223-3AC73-3...
1750
1800
9.1
79
94
2500
1XB7 730
6SL3710-1GH33-3AA3
320
1.M1223-3BC53-3...
2220
2270
14.6
79
95
2200
1XB7 731
6SL3710-1GH34-1AA3
400
1.M1223-3BC73-3...
2370
2420
16.1
79
95
2200
1XB7 731
6SL3710-1GH34-1AA3
400
Siemens D 81.8 · 04/2014
4
4/13
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency
■ Selection and ordering data
4
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LM1/1MM1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V
3600 rpm, 4-pole
235
315
315
Δ
120.4 623
95.6
95.9
95.2
0.87
340
8.7
3.0
1■M1212-3AB15-5■■■
275
369
315
Δ
120.4 730
95.8
96.1
95.4
0.87
395
10.7
3.6
1■M1212-3AB35-5■■■
320
429
315
Δ
120.5 849
95.7
96.1
95.5
0.90
445
8.5
2.8
1■M1212-3AB55-5■■■
360
483
315
Δ
120.5 955
95.9
96.2
95.7
0.90
500
9.3
3.0
1■M1212-3AB75-5■■■
3000 rpm, 4-pole
420
563
355
Δ
100.5 1337
95.7
96.3
95.9
0.89
590
6.6
2.4
1■M1212-3BB55-1■■■
1■M1212-3BB75-1■■■
465
624
355
Δ
100.4 1480
95.9
96.4
95.9
0.89
650
7.7
2.8
1800 rpm, 4-pole
260
349
315
Δ
60.5
1379
95.1
95.8
95.5
0.85
385
8.4
3.1
1■M1212-3AB15-6■■■
1■M1212-3AB35-6■■■
320
429
315
Δ
60.5
1698
95.4
96.0
95.9
0.88
455
8.7
3.1
1■M1212-3AB55-6■■■
355
476
315
Δ
60.5
1883
95.5
96.1
96.0
0.89
500
8.9
3.1
430
577
315
Δ
60.4
2283
95.9
96.4
96.2
0.86
620
10.9
3.2
1■M1212-3AB75-6■■■
520
697
355
Δ
60.4
2759
95.6
96.3
96.0
0.87
750
8.6
3.3
1■M1212-3BB55-6■■■
1■M1212-3BB75-6■■■
545
731
355
Δ
60.4
2892
95.6
96.3
96.2
0.89
760
7.9
3.0
1200 rpm, 6-pole
215
288
315
Δ
60.5
1712
95.0
95.7
95.6
0.81
335
8.1
2.5
1■M1212-3AC15-7■■■
260
349
315
Δ
60.4
2070
95.3
95.7
95.9
0.83
390
8.6
2.6
1■M1212-3AC35-7■■■
310
416
315
Δ
60.4
2468
95.5
95.7
96.0
0.83
475
9.0
2.8
1■M1212-3AC55-7■■■
1■M1212-3AC75-7■■■
335
449
315
Δ
60.4
2666
95.5
95.7
96.1
0.84
500
8.9
2.7
395
530
355
Δ
60.3
3144
95.4
95.9
95.5
0.84
590
11.0
3.1
1■M1212-3BC55-7■■■
1■M1212-3BC75-7■■■
445
597
355
Δ
60.3
3542
95.4
96.0
95.6
0.85
660
10.5
2.8
900 rpm, 6-pole
175
235
315
Δ
45.4
1858
94.6
95.4
95.3
0.79
280
8.4
2.8
1■M1212-3AC15-8■■■
1■M1212-3AC35-8■■■
210
282
315
Δ
45.4
2229
94.9
95.6
95.4
0.76
350
9.2
3.2
245
329
315
Δ
45.4
2601
94.8
95.7
95.7
0.83
370
8.2
2.6
1■M1212-3AC55-8■■■
1■M1212-3AC75-8■■■
270
362
315
Δ
45.4
2866
94.9
95.8
95.8
0.83
410
8.3
2.6
310
416
355
Δ
45.3
3291
94.8
95.6
95.5
0.86
455
9.4
3.0
1■M1212-3BC55-8■■■
345
463
355
Δ
45.3
3661
95.0
95.7
95.5
0.85
510
9.7
2.7
1■M1212-3BC75-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G120P, SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V
3600 rpm, 4-pole
230
308
315
Δ
120.4 610
95.6
95.8
95.1
0.87
360
9.6
3.2
1■M1222-3AB15-5■■■
285
382
315
Δ
120.5 756
95.9
96.2
95.7
0.89
435
8.8
2.9
1■M1222-3AB35-5■■■
315
422
315
Δ
120.4 836
95.8
96.0
95.3
0.89
485
9.8
3.2
1■M1222-3AB55-5■■■
1■M1222-3AB75-5■■■
340
456
315
Δ
120.4 902
95.8
96.0
95.3
0.88
530
11.6
3.9
3000 rpm, 4-pole
420
563
355
Δ
100.4 1337
95.8
96.3
95.8
0.89
640
7.6
2.7
1■M1222-3BB55-1■■■
450
603
355
Δ
100.5 1433
95.8
96.4
96.0
0.89
690
6.6
2.4
1■M1222-3BB75-1■■■
1800 rpm, 4-pole
255
342
315
Δ
60.4
1353
95.1
95.7
95.5
0.85
410
8.6
3.2
1■M1222-3AB15-6■■■
320
429
315
Δ
60.4
1698
95.4
96.1
95.9
0.87
500
9.0
3.2
1■M1222-3AB35-6■■■
365
489
315
Δ
60.4
1937
95.5
96.1
96.0
0.88
570
9.1
3.2
1■M1222-3AB55-6■■■
420
563
315
Δ
60.4
2228
95.7
96.3
96.2
0.89
640
9.5
3.3
1■M1222-3AB75-6■■■
500
671
355
Δ
60.4
2653
95.5
96.2
96.0
0.88
770
7.6
2.9
1■M1222-3BB55-6■■■
560
751
355
Δ
60.4
2971
95.7
96.4
96.2
0.88
870
8.7
3.3
1■M1222-3BB75-6■■■
1200 rpm, 6-pole
220
295
315
Δ
60.4
1751
95.2
95.7
95.6
0.79
380
9.0
2.9
1■M1222-3AC15-7■■■
265
355
315
Δ
60.4
2109
95.4
95.7
95.9
0.82
440
8.9
2.7
1■M1222-3AC35-7■■■
305
409
315
Δ
60.4
2428
95.5
95.7
96.0
0.83
500
8.9
2.7
1■M1222-3AC55-7■■■
340
456
315
Δ
60.4
2706
95.6
95.7
96.2
0.84
550
8.6
2.6
1■M1222-3AC75-7■■■
395
530
355
Δ
60.3
3144
95.4
95.9
95.5
0.84
640
10.9
3.1
1■M1222-3BC55-7■■■
1■M1222-3BC75-7■■■
435
583
355
Δ
60.3
3462
95.5
96.0
95.6
0.85
700
10.8
2.9
900 rpm, 6-pole
170
228
315
Δ
45.4
1804
94.5
95.3
95.1
0.76
310
8.8
3.1
1■M1222-3AC15-8■■■
215
288
315
Δ
45.4
2282
94.8
95.6
95.5
0.80
370
8.7
2.9
1■M1222-3AC35-8■■■
245
329
315
Δ
45.4
2600
94.8
95.7
95.7
0.82
410
8.4
2.7
1■M1222-3AC55-8■■■
270
362
315
Δ
45.4
2866
94.9
95.8
95.8
0.84
440
8.0
2.6
1■M1222-3AC75-8■■■
310
416
355
Δ
45.3
3290
94.9
95.6
95.4
0.85
500
10.0
3.0
1■M1222-3BC55-8■■■
345
463
355
Δ
45.3
3661
95.1
95.8
95.5
0.84
560
10.8
2.7
1■M1222-3BC75-8■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC75-8■■■
Prated
4/14
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.M1212-3AB15-5...
1.M1212-3AB35-5...
1.M1212-3AB55-5...
1.M1212-3AB75-5...
1260
1440
1620
1780
1310
1490
1670
1830
3.5
4.4
5.1
5.9
79
79
79
79
94
94
94
94
3600
3600
3600
3600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LE33-8AA3
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
370
477
477
590
1.M1212-3BB55-1...
1.M1212-3BB75-1...
2220
2350
2280
2410
8.4
9
79
79
95
95
3300
3300
1XB7 731
1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
590
725
1.M1212-3AB15-6...
1.M1212-3AB35-6...
1.M1212-3AB55-6...
1.M1212-3AB75-6...
1.M1212-3BB55-6...
1.M1212-3BB75-6...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
2750
2750
2750
2750
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE38-4AA3
477
477
590
725
820
820
1.M1212-3AC15-7...
1.M1212-3AC35-7...
1.M1212-3AC55-7...
1.M1212-3AC75-7...
1.M1212-3BC55-7...
1.M1212-3BC75-7...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-7LE33-8AA3
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
370
477
477
590
590
725
1.M1212-3AC15-8...
1.M1212-3AC35-8...
1.M1212-3AC55-8...
1.M1212-3AC75-8...
1.M1212-3BC55-8...
1.M1212-3BC75-8...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LE33-1AA3
6SL3710-7LE33-8AA3
6SL3710-7LE33-8AA3
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
302
370
370
477
477
590
1.M1222-3AB15-5...
1.M1222-3AB35-5...
1.M1222-3AB55-5...
1.M1222-3AB75-5...
1260
1440
1620
1780
1310
1490
1670
1830
3.5
4.4
5.1
5.9
79
79
79
79
94
94
94
94
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1PE33-7AA0
6SL3710-1PE34-6AA0
6SL3710-1PE35-8AA0
6SL3710-1PE35-8AA0
360
450
570
570
1.M1222-3BB55-1...
1.M1222-3BB75-1...
2220
2350
2280
2410
8.4
9
79
79
95
95
3300
3300
1XB7 740
1XB7 740
6SL3370-1PE36-6AA0
6SL3710-1PE37-4AA0
640
710
1.M1222-3AB15-6...
1.M1222-3AB35-6...
1.M1222-3AB55-6...
1.M1222-3AB75-6...
1.M1222-3BB55-6...
1.M1222-3BB75-6...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
2750
2750
2750
2750
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1PE34-6AA0
6SL3710-1PE35-8AA0
6SL3710-1PE35-8AA0
6SL3370-1PE36-6AA0
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
450
570
570
640
820
960
1.M1222-3AC15-7...
1.M1222-3AC35-7...
1.M1222-3AC55-7...
1.M1222-3AC75-7...
1.M1222-3BC55-7...
1.M1222-3BC75-7...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1PE34-6AA0
6SL3710-1PE34-6AA0
6SL3710-1PE35-8AA0
6SL3710-1PE35-8AA0
6SL3370-1PE36-6AA0
6SL3710-1PE37-4AA0
450
450
570
570
640
710
1.M1222-3AC15-8...
1.M1222-3AC35-8...
1.M1222-3AC55-8...
1.M1222-3AC75-8...
1.M1222-3BC55-8...
1.M1222-3BC75-8...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1PE33-7AA0
6SL3710-1PE34-6AA0
6SL3710-1PE34-6AA0
6SL3710-1PE34-6AA0
6SL3710-1PE35-8AA0
6SL3710-1PE35-8AA0
360
450
450
450
570
570
Siemens D 81.8 · 04/2014
4
4/15
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LM1/1MM1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V
1800 rpm, 4-pole
4
235
315
315
Δ
60.4
1247
95.4
96.2
95.8
0.84
350
9.2
3.5
1■M1213-3AB15-6■■■
290
389
315
Δ
60.4
1539
95.7
96.3
96.2
0.87
415
9.6
3.4
1■M1213-3AB35-6■■■
365
489
315
Δ
60.5
1937
95.5
96.2
96.1
0.89
510
8.7
3.0
1■M1213-3AB55-6■■■
445
597
315
Δ
60.4
2363
95.9
96.5
96.4
0.87
640
10.4
3.1
1■M1213-3AB75-6■■■
550
738
355
Δ
60.4
2918
95.8
96.5
96.4
0.87
790
8.2
3.1
1■M1213-3BB55-6■■■
570
764
355
Δ
60.4
3025
95.7
96.5
96.5
0.89
800
7.5
2.8
1■M1213-3BB75-6■■■
1200 rpm, 6-pole
220
295
315
Δ
60.5
1752
95.0
95.9
95.8
0.81
340
8.0
2.5
1■M1213-3AC15-7■■■
270
362
315
Δ
60.4
2150
95.3
96.1
96.1
0.83
405
8.2
2.5
1■M1213-3AC35-7■■■
310
416
315
Δ
60.4
2468
95.6
96.3
96.2
0.82
470
9.1
2.8
1■M1213-3AC55-7■■■
345
463
315
Δ
60.4
2746
95.6
96.3
96.3
0.83
520
8.5
2.6
1■M1213-3AC75-7■■■
435
583
355
Δ
60.3
3462
95.7
96.4
96.2
0.84
650
9.9
2.9
1■M1213-3BC55-7■■■
475
637
355
Δ
60.3
3781
95.7
96.4
96.3
0.85
700
9.9
2.6
1■M1213-3BC75-7■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G120P, SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V
1800 rpm, 4-pole
235
315
315
Δ
60.4
1247
95.4
96.2
95.8
0.84
380
9.3
3.5
1■M1223-3AB15-6■■■
290
389
315
Δ
60.4
1540
95.7
96.3
96.2
0.86
460
9.8
3.6
1■M1223-3AB35-6■■■
370
496
315
Δ
60.4
1963
95.6
96.3
96.2
0.88
570
9.1
3.2
1■M1223-3AB55-6■■■
430
577
315
Δ
60.4
2281
95.7
96.4
96.4
0.89
660
9.2
3.2
1■M1223-3AB75-6■■■
520
697
355
Δ
60.5
2759
95.6
96.4
96.4
0.88
800
7.3
2.8
1■M1223-3BB55-6■■■
590
791
355
Δ
60.4
3130
95.9
96.6
96.5
0.88
910
8.4
3.2
1■M1223-3BB75-6■■■
1200 rpm, 6-pole
225
302
315
Δ
60.4
1791
95.3
96.0
95.9
0.79
390
8.8
2.8
1■M1223-3AC15-7■■■
270
362
315
Δ
60.4
2149
95.4
96.2
96.1
0.82
450
8.6
2.7
1■M1223-3AC35-7■■■
315
422
315
Δ
60.4
2507
95.5
96.3
96.2
0.83
520
8.5
2.6
1■M1223-3AC55-7■■■
350
469
315
Δ
60.4
2786
95.6
96.4
96.3
0.84
570
8.3
2.6
1■M1223-3AC75-7■■■
430
577
355
Δ
60.3
3423
95.6
96.4
96.1
0.84
700
9.9
2.9
1■M1223-3BC55-7■■■
470
630
355
Δ
60.3
3741
95.7
96.5
96.3
0.85
750
10.0
2.6
1■M1223-3BC75-7■■■
For versions, see Article No. supplements and special versions
4/16
Siemens D 81.8 · 04/2014
1■M1223-3AC75-7■■■
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.M1213-3AB15-6...
1260
1310
3.5
79
94
3000
1XB7 730
6SL3710-7LE33-8AA3
370
1.M1213-3AB35-6...
1440
1490
4.4
79
94
3000
1XB7 731
6SL3710-7LE35-0AA3
477
1.M1213-3AB55-6...
1620
1670
5.1
79
94
2750
1XB7 731
6SL3710-7LE36-1AA3
590
1.M1213-3AB75-6...
1780
1830
5.9
79
94
2750
1XB7 740
6SL3710-7LE37-5AA3
725
1.M1213-3BB55-6...
2220
2280
8.4
79
95
2200
1XB7 740
6SL3710-7LE38-4AA3
820
1.M1213-3BB75-6...
2350
2410
9
79
95
2200
1XB7 740
6SL3710-7LE38-4AA3
820
1.M1213-3AC15-7...
1290
1340
5.9
79
94
2500
1XB7 730
6SL3710-7LE33-8AA3
370
1.M1213-3AC35-7...
1460
1510
7.3
79
94
2500
1XB7 731
6SL3710-7LE35-0AA3
477
1.M1213-3AC55-7...
1650
1700
8.3
79
94
2500
1XB7 731
6SL3710-7LE35-0AA3
477
1.M1213-3AC75-7...
1750
1800
9.1
79
94
2500
1XB7 731
6SL3710-7LE36-1AA3
590
1.M1213-3BC55-7...
2220
2270
14.6
79
95
2200
1XB7 740
6SL3710-7LE37-5AA3
725
1.M1213-3BC75-7...
2370
2420
16.1
79
95
2200
1XB7 740
6SL3710-7LE37-5AA3
725
1.M1223-3AB15-6...
1260
1310
3.5
79
94
3000
1XB7 731
6SL3710-1PE34-6AA0
450
1.M1223-3AB35-6...
1440
1490
4.4
79
94
3000
1XB7 731
6SL3710-1PE35-8AA0
570
1.M1223-3AB55-6...
1620
1670
5.1
79
94
2750
1XB7 731
6SL3710-1PE35-8AA0
570
1.M1223-3AB75-6...
1780
1830
5.9
79
94
2750
1XB7 740
6SL3710-1PE37-4AA0
710
1.M1223-3BB55-6...
2220
2280
8.4
79
95
2200
1XB7 740
6SL3710-1GE38-4AA3
820
1.M1223-3BB75-6...
2350
2410
9
79
95
2200
1XB7 740
6SL3710-1GE41-0AA3
960
1.M1223-3AC15-7...
1290
1340
5.9
79
94
2500
1XB7 731
6SL3710-1PE34-6AA0
450
1.M1223-3AC35-7...
1460
1510
7.3
79
94
2500
1XB7 731
6SL3710-1PE34-6AA0
450
1.M1223-3AC55-7...
1650
1700
8.3
79
94
2500
1XB7 731
6SL3710-1PE35-8AA0
570
1.M1223-3AC75-7...
1750
1800
9.1
79
94
2500
1XB7 731
6SL3710-1PE35-8AA0
570
1.M1223-3BC55-7...
2220
2270
14.6
79
95
2200
1XB7 740
6SL3710-1PE37-4AA0
710
1.M1223-3BC75-7...
2370
2420
16.1
79
95
2200
1XB7 740
6SL3710-1GE38-4AA3
820
Siemens D 81.8 · 04/2014
4
4/17
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency
■ Selection and ordering data
4
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LM1/1MM1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V
3600 rpm, 4-pole
220
295
315
Δ
120.5 584
95.5
95.8
95.1
0.88
245
8.6
2.8
1■M1212-3AB16-5■■■
270
362
315
Δ
120.4 717
95.8
96.0
95.3
0.87
305
10.6
3.6
1■M1212-3AB36-5■■■
300
402
315
Δ
120.4 796
95.6
95.8
95.1
0.88
335
11.1
3.7
1■M1212-3AB56-5■■■
340
456
315
Δ
120.4 902
95.8
96.0
95.3
0.88
380
11.5
3.8
1■M1212-3AB76-5■■■
3000 rpm, 4-pole
405
543
355
Δ
100.5 1289
95.6
96.2
95.8
0.89
450
6.6
2.4
1■M1212-3BB56-1■■■
1■M1212-3BB76-1■■■
450
603
355
Δ
100.5 1433
95.7
96.3
95.9
0.89
495
7.2
2.6
1800 rpm, 4-pole
235
315
315
Δ
60.4
1247
94.9
95.6
95.3
0.86
270
8.5
3.1
1■M1212-3AB16-6■■■
1■M1212-3AB36-6■■■
300
402
315
Δ
60.4
1593
95.4
96.0
95.7
0.85
350
10.2
3.8
1■M1212-3AB56-6■■■
335
449
315
Δ
60.4
1777
95.5
96.1
95.8
0.87
380
10.0
3.6
395
530
315
Δ
60.4
2097
95.8
96.3
96.0
0.86
450
11.5
3.5
1■M1212-3AB76-6■■■
480
644
355
Δ
60.4
2547
95.5
96.2
95.9
0.87
540
9.2
3.5
1■M1212-3BB56-6■■■
1■M1212-3BB76-6■■■
520
697
355
Δ
60.3
2761
95.7
96.3
95.9
0.86
590
10.1
3.6
1200 rpm, 6-pole
200
268
315
Δ
60.4
1592
95.0
95.7
95.4
0.79
250
9.2
2.9
1■M1212-3AC16-7■■■
240
322
315
Δ
60.4
1910
95.3
95.7
95.6
0.81
295
9.7
3.0
1■M1212-3AC36-7■■■
280
375
315
Δ
60.4
2229
95.3
95.7
95.9
0.83
335
8.9
2.8
1■M1212-3AC56-7■■■
1■M1212-3AC76-7■■■
305
409
315
Δ
60.4
2428
95.4
95.7
95.9
0.83
360
9.4
2.9
360
483
355
Δ
60.3
2865
95.3
95.7
95.1
0.81
440
12.4
3.5
1■M1212-3BC56-7■■■
1■M1212-3BC76-7■■■
395
530
355
Δ
60.3
3144
95.3
95.8
95.3
0.83
470
12.0
3.1
900 rpm, 6-pole
155
208
315
Y
45.4
1645
94.4
95.1
95.0
0.78
198
9.0
3.0
1■M1212-3AC16-8■■■
1■M1212-3AC36-8■■■
190
255
315
Δ
45.3
2016
94.9
95.5
95.2
0.75
250
9.8
3.5
230
308
315
Δ
45.4
2441
94.8
95.6
95.5
0.82
280
8.8
2.9
1■M1212-3AC56-8■■■
1■M1212-3AC76-8■■■
245
329
315
Δ
45.3
2600
94.9
95.7
95.5
0.80
305
9.6
2.8
290
389
355
Δ
45.3
3077
94.8
95.5
95.2
0.84
340
10.7
3.2
1■M1212-3BC56-8■■■
320
429
355
Δ
45.3
3395
94.9
95.6
95.3
0.84
375
10.8
2.9
1■M1212-3BC76-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V
3600 rpm, 4-pole
205
275
315
Δ
120.4 544
95.4
95.6
94.8
0.86
260
10.8
3.7
1■M1222-3AB16-5■■■
235
315
315
Δ
120.3 624
95.6
95.7
94.9
0.86
300
12.3
4.2
1■M1222-3AB36-5■■■
255
342
315
Δ
120.3 677
95.3
95.4
94.4
0.85
330
13.3
4.6
1■M1222-3AB56-5■■■
1■M1222-3AB76-5■■■
330
443
315
Δ
120.4 875
95.8
96.1
95.5
0.90
400
9.7
3.2
3000 rpm, 4-pole
395
530
355
Δ
100.5 1258
95.6
96.2
95.7
0.89
485
7.0
2.5
1■M1222-3BB56-1■■■
425
570
355
Δ
100.4 1353
95.8
96.2
95.8
0.89
520
8.1
2.9
1■M1222-3BB76-1■■■
1800 rpm, 4-pole
230
308
315
Δ
60.5
1220
94.9
95.5
95.3
0.87
290
8.2
3.0
1■M1222-3AB16-6■■■
295
396
315
Δ
60.4
1567
95.4
95.9
95.7
0.86
375
10.1
3.6
1■M1222-3AB36-6■■■
330
443
315
Δ
60.4
1751
95.5
96.1
95.8
0.87
415
10.0
3.6
1■M1222-3AB56-6■■■
390
523
315
Δ
60.3
2070
95.8
96.3
96.0
0.85
500
11.8
3.6
1■M1222-3AB76-6■■■
475
637
355
Δ
60.3
2522
95.6
96.2
95.8
0.86
600
9.5
3.6
1■M1222-3BB56-6■■■
505
677
355
Δ
60.4
2679
95.5
96.2
96.0
0.88
630
8.4
3.2
1■M1222-3BB76-6■■■
1200 rpm, 6-pole
185
248
315
Δ
60.4
1473
94.9
95.6
95.4
0.81
250
8.9
2.7
1■M1222-3AC16-7■■■
235
315
315
Δ
60.4
1870
95.3
95.7
95.6
0.81
320
9.7
3.1
1■M1222-3AC36-7■■■
275
369
315
Δ
60.4
2189
95.3
95.7
95.8
0.83
360
9.3
2.8
1■M1222-3AC56-7■■■
300
402
315
Δ
60.4
2388
95.5
95.7
95.9
0.83
400
9.7
3.0
1■M1222-3AC76-7■■■
350
469
355
Δ
60.3
2786
95.2
95.7
95.2
0.83
465
11.9
3.6
1■M1222-3BC56-7■■■
1■M1222-3BC76-7■■■
370
496
355
Δ
60.2
2947
95.3
95.7
95.0
0.79
510
13.4
3.4
900 rpm, 6-pole
150
201
315
Δ
45.3
1592
94.5
95.1
94.8
0.73
225
9.6
3.4
1■M1222-3AC16-8■■■
185
248
315
Δ
45.3
1963
94.8
95.4
95.0
0.74
275
10.1
3.6
1■M1222-3AC36-8■■■
220
295
315
Δ
45.4
2335
94.8
95.6
95.4
0.80
300
9.6
3.2
1■M1222-3AC56-8■■■
245
329
315
Δ
45.4
2600
94.9
95.7
95.5
0.80
335
9.5
2.8
1■M1222-3AC76-8■■■
280
375
355
Δ
45.3
2971
94.8
95.5
95.2
0.84
365
10.9
3.3
1■M1222-3BC56-8■■■
300
402
355
Δ
45.3
3184
94.9
95.6
95.2
0.83
395
11.4
3.1
1■M1222-3BC76-8■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC76-8■■■
Prated
4/18
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.M1212-3AB16-5...
1.M1212-3AB36-5...
1.M1212-3AB56-5...
1.M1212-3AB76-5...
1260
1440
1620
1780
1310
1490
1670
1830
3.5
4.4
5.1
5.9
79
79
79
79
94
94
94
94
3600
3600
3600
3600
1XB7 730
1XB7 730
1XB7 730
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
250
320
400
400
1.M1212-3BB56-1...
1.M1212-3BB76-1...
2220
2350
2280
2410
8.4
9
79
79
95
95
3300
3300
1XB7 731
1XB7 731
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
452
560
1.M1212-3AB16-6...
1.M1212-3AB36-6...
1.M1212-3AB56-6...
1.M1212-3AB76-6...
1.M1212-3BB56-6...
1.M1212-3BB76-6...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
2750
2750
2750
2750
2200
2200
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
320
400
400
452
560
710
1.M1212-3AC16-7...
1.M1212-3AC36-7...
1.M1212-3AC56-7...
1.M1212-3AC76-7...
1.M1212-3BC56-7...
1.M1212-3BC76-7...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
250
320
400
400
452
560
1.M1212-3AC16-8...
1.M1212-3AC36-8...
1.M1212-3AC56-8...
1.M1212-3AC76-8...
1.M1212-3BC56-8...
1.M1212-3BC76-8...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
6SL3710-7LG32-2AA3
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
208
250
320
320
400
400
1.M1222-3AB16-5...
1.M1222-3AB36-5...
1.M1222-3AB56-5...
1.M1222-3AB76-5...
1260
1440
1620
1780
1310
1490
1670
1830
3.5
4.4
5.1
5.9
79
79
79
79
94
94
94
94
3600
3600
3600
3600
1XB7 730
1XB7 730
1XB7 730
1XB7 731
6SL3710-1GF33-3AA3
6SL3710-1GF33-3AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-1AA3
320
320
400
400
1.M1222-3BB56-1...
1.M1222-3BB76-1...
2220
2350
2280
2410
8.4
9
79
79
95
95
3300
3300
1XB7 731
1XB7 731
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
560
560
1.M1222-3AB16-6...
1.M1222-3AB36-6...
1.M1222-3AB56-6...
1.M1222-3AB76-6...
1.M1222-3BB56-6...
1.M1222-3BB76-6...
1260
1440
1620
1780
2220
2350
1310
1490
1670
1830
2280
2410
3.5
4.4
5.1
5.9
8.4
9
79
79
79
79
79
79
94
94
94
94
95
95
2750
2750
2750
2750
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GF33-3AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
320
400
452
560
710
710
1.M1222-3AC16-7...
1.M1222-3AC36-7...
1.M1222-3AC56-7...
1.M1222-3AC76-7...
1.M1222-3BC56-7...
1.M1222-3BC76-7...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GF32-6AA3
6SL3710-1GF33-3AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-1AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
250
320
400
400
560
560
1.M1222-3AC16-8...
1.M1222-3AC36-8...
1.M1222-3AC56-8...
1.M1222-3AC76-8...
1.M1222-3BC56-8...
1.M1222-3BC76-8...
1290
1460
1650
1750
2220
2370
1340
1510
1700
1800
2270
2420
5.9
7.3
8.3
9.1
14.6
16.1
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-1GF32-6AA3
6SL3710-1GF33-3AA3
6SL3710-1GF33-3AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-1AA3
250
320
320
400
400
400
Siemens D 81.8 · 04/2014
4
4/19
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LM1/1MM1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V
1800 rpm, 4-pole
4
125
168
315
Δ
60.2
663
95.3
95.8
94.7
0.74
166
13.8
5.9
1■M1213-3AB16-6■■■
265
355
315
Δ
60.3
1407
95.7
96.2
95.9
0.83
315
11.2
4.2
1■M1213-3AB36-6■■■
345
463
315
Δ
60.4
1830
95.5
96.2
96.0
0.87
390
9.7
3.5
1■M1213-3AB56-6■■■
395
530
315
Δ
60.4
2097
95.8
96.4
96.2
0.86
450
11.4
3.5
1■M1213-3AB76-6■■■
510
684
355
Δ
60.4
2706
95.7
96.4
96.3
0.87
580
8.5
3.3
1■M1213-3BB56-6■■■
560
751
355
Δ
60.4
2973
95.9
96.6
96.4
0.86
640
9.3
3.3
1■M1213-3BB76-6■■■
1200 rpm, 6-pole
210
282
315
Δ
60.4
1672
95.1
95.9
95.7
0.80
260
8.9
2.8
1■M1213-3AC16-7■■■
250
335
315
Δ
60.4
1990
95.3
96.0
95.9
0.81
305
9.3
2.9
1■M1213-3AC36-7■■■
285
382
315
Δ
60.4
2268
95.4
96.1
96.1
0.83
340
8.8
2.7
1■M1213-3AC56-7■■■
315
422
315
Δ
60.4
2507
95.5
96.2
96.1
0.83
375
9.0
2.8
1■M1213-3AC76-7■■■
395
530
355
Δ
60.3
3144
95.6
96.2
95.9
0.80
485
11.2
3.1
1■M1213-3BC56-7■■■
435
583
355
Δ
60.3
3462
95.7
96.3
96.1
0.83
520
10.8
2.9
1■M1213-3BC76-7■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V
1800 rpm, 4-pole
125
168
315
Δ
60.3
663
95.3
95.8
95.0
0.78
177
13.3
5.4
1■M1223-3AB16-6■■■
265
355
315
Δ
60.3
1407
95.6
96.2
96.0
0.84
345
10.9
4.1
1■M1223-3AB36-6■■■
340
456
315
Δ
60.4
1804
95.5
96.2
96.0
0.88
420
9.8
3.5
1■M1223-3AB56-6■■■
400
536
315
Δ
60.3
2123
95.8
96.4
96.2
0.85
510
11.5
3.5
1■M1223-3AB76-6■■■
505
677
355
Δ
60.4
2679
95.8
96.5
96.3
0.86
640
8.9
3.4
1■M1223-3BB56-6■■■
530
711
355
Δ
60.4
2812
95.7
96.4
96.4
0.88
660
8.0
3.0
1■M1223-3BB76-6■■■
1200 rpm, 6-pole
175
235
315
Δ
60.4
1393
95.0
95.8
95.6
0.81
235
9.4
2.9
1■M1223-3AC16-7■■■
250
335
315
Δ
60.4
1990
95.3
96.0
95.9
0.81
335
9.2
2.9
1■M1223-3AC36-7■■■
285
382
315
Δ
60.4
2269
95.4
96.1
96.1
0.83
375
8.8
2.7
1■M1223-3AC56-7■■■
315
422
315
Δ
60.4
2507
95.5
96.2
96.1
0.83
415
9.3
2.9
1■M1223-3AC76-7■■■
385
516
355
Δ
60.3
3064
95.6
96.2
96.0
0.83
510
10.8
3.2
1■M1223-3BC56-7■■■
405
543
355
Δ
60.3
3226
95.7
96.3
95.9
0.79
560
12.2
3.1
1■M1223-3BC76-7■■■
For versions, see Article No. supplements and special versions
4/20
Siemens D 81.8 · 04/2014
1■M1223-3AC76-7■■■
© Siemens AG 2014
Self-ventilated motors — enclosed version
1LM1/1MM1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.M1213-3AB16-6...
1260
1310
3.5
79
94
3000
1XB7 730
6SL3710-7LG31-8AA3
170
1.M1213-3AB36-6...
1440
1490
4.4
79
94
3000
1XB7 730
6SL3710-7LG33-3AA3
320
1.M1213-3AB56-6...
1620
1670
5.1
79
94
2750
1XB7 731
6SL3710-7LG34-1AA3
400
1.M1213-3AB76-6...
1780
1830
5.9
79
94
2750
1XB7 731
6SL3710-7LG34-7AA3
452
1.M1213-3BB56-6...
2220
2280
8.4
79
95
2200
1XB7 731
6SL3710-7LG37-4AA3
710
1.M1213-3BB76-6...
2350
2410
9
79
95
2200
1XB7 740
6SL3710-7LG37-4AA3
710
1.M1213-3AC16-7...
1290
1340
5.9
79
94
2500
1XB7 730
6SL3710-7LG33-3AA3
320
1.M1213-3AC36-7...
1460
1510
7.3
79
94
2500
1XB7 730
6SL3710-7LG33-3AA3
320
1.M1213-3AC56-7...
1650
1700
8.3
79
94
2500
1XB7 730
6SL3710-7LG34-1AA3
400
1.M1213-3AC76-7...
1750
1800
9.1
79
94
2500
1XB7 731
6SL3710-7LG34-1AA3
400
1.M1213-3BC56-7...
2220
2270
14.6
79
95
2200
1XB7 731
6SL3710-7LG35-8AA3
560
1.M1213-3BC76-7...
2370
2420
16.1
79
95
2200
1XB7 731
6SL3710-7LG35-8AA3
560
1.M1223-3AB16-6...
1260
1310
3.5
79
94
3000
1XB7 730
6SL3710-1GF32-2AA3
208
1.M1223-3AB36-6...
1440
1490
4.4
79
94
3000
1XB7 730
6SL3710-1GF34-1AA3
400
1.M1223-3AB56-6...
1620
1670
5.1
79
94
2750
1XB7 731
6SL3710-1GF34-7AA3
452
1.M1223-3AB76-6...
1780
1830
5.9
79
94
2750
1XB7 731
6SL3710-1GF35-8AA3
560
1.M1223-3BB56-6...
2220
2280
8.4
79
95
2200
1XB7 740
6SL3710-1GF37-4AA3
710
1.M1223-3BB76-6...
2350
2410
9
79
95
2200
1XB7 740
6SL3710-1GF37-4AA3
710
1.M1223-3AC16-7...
1290
1340
5.9
79
94
2500
1XB7 730
6SL3710-1GF32-6AA3
250
1.M1223-3AC36-7...
1460
1510
7.3
79
94
2500
1XB7 730
6SL3710-1GF34-1AA3
400
1.M1223-3AC56-7...
1650
1700
8.3
79
94
2500
1XB7 731
6SL3710-1GF34-1AA3
400
1.M1223-3AC76-7...
1750
1800
9.1
79
94
2500
1XB7 731
6SL3710-1GF34-7AA3
452
1.M1223-3BC56-7...
2220
2270
14.6
79
95
2200
1XB7 731
6SL3710-1GF35-8AA3
560
1.M1223-3BC76-7...
2370
2420
16.1
79
95
2200
1XB7 731
6SL3710-1GF35-8AA3
560
Siemens D 81.8 · 04/2014
4
4/21
© Siemens AG 2014
Self-ventilated motors — enclosed version
Dimensions
1LM1/1MM1 motors
■ Dimensional drawings
IM B3 type of construction
For terminal box dimensions, see Page 4/24
L
LL
BE
HB'
HK
HC
GA
HD
AC
ØD
F
HB
AG
4
AD
BC
H
HA
EB
DB
BA
E
G_D081_XX_00416
C
ØK
B
BB
Ø K'
AA
A
AB
IM B35 and IM V1 types of construction
For flange dimensions, see Page 4/23 (Z = the number of retaining holes),
For terminal box dimensions, see Page 4/24
L
LL
HC
HB'
HK
HH
BE
AG
AD
LM
HB
ZxS
GA
AQ
AC
ØP
ØN
ØD
F
E
DB
G_D081_XX_00417
BA
LA
LE
C
Frame No. of
size
poles
Motor type
315
1.M12..-3A.1.-....
1.M12..-3A.3.-....
4, 6
4, 6
1.M12..-3A.5.-....
1.M12..-3A.7.-....
ØK
Ø K'
B
BB
AA
AB
AC AQ B
BA
BB
C
H
HA K
K'
L
LM
D
560 120 680 630 670 630 180 780 180 315 28 28 35 1470 1615 85
● 560 120 680 630 670 630 180 780 200 315 28 28 35 1490 1635 95
560 120 680 630 670 835 180 985 180 315 28 28 35 1610 1755 85
DB
E
EB
F
GA
M20 170 140 22 90
M24 170 140 25 100
M20 170 140 22 90
● 560 120 680 630 670 835 180 985 200 315 28 28 35 1630 1775 95
M24 170 140 25 100
630 150 780 710 750 800 220 980 200 355 35 35 42 1730 1900 95
M24 170 140 25 100
● 630 150 780 710 750 800 220 980 224 355 35 35 42 1795 1965 100 M24 210 180 28 106
● Bearing design for increased cantilever forces, for type of construction IM B3 only.
4/22
AA
A
AB
Dimension designation acc. to IEC
A
1.M12..-3A.5.-....
1.M12..-3A.7.-....
355
M
H
HA
EB
HD
T
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Self-ventilated motors — enclosed version
Dimensions
Flanges
G_D081_XX_00026
■ Dimensional drawings
(Z = the number of retaining holes)
4
Flange with through holes
Motor type
Frame size
No. of poles
Type of construction
Flange type
Dimension designation acc. to IEC
LA
1LM1/1MM1
315
355
4, 6
4, 6
IM B35, IM V1
IM B35, IM V1
LE
M
N
P
S
T
Z
Flange
29
170
740
680
800
22
6
8
Flange (optional)
22
170
600
550
660
22
6
8
Flange
29
170
840
780
900
22
6
8
Flange (optional)
22
170
600
550
660
22
6
8
Siemens D 81.8 · 04/2014
4/23
© Siemens AG 2014
Self-ventilated motors — enclosed version
Dimensions
Terminal boxes
■ Dimensional drawings
LL
BE
HB'
HK
HC
AG1
IM B3 type of construction
HD
HB
AG
AD
BC
4
G_D081_XX_00426
LL
HC
HB'
HK
HH
AG1
IM B35 and IM V1 types of construction
HD
HB
AG
AD
BE
G_D081_XX_00427
Motor
type
Frame
size
No. of
poles
Terminal
box
Dimension designation acc. to IEC
AD
AG
AG1
BC
BE
HB
HB'
HH
HC
HD
HK
LL
1LM1/
1MM1
315
4, 6
1XB7 730
710
575
–
115
–
890
310
295
180
1025
255
345
1XB7 731
710
575
–
115
115
890
310
295
180
1025
255
345
1XB7 740
800
615
60
115
150
930
365
295
235
1110
335
425
GT640
655
555
–
115
110
870
225
295
155
970
170
310
1XB1 621
705
585
–
115
150
900
305
295
165
1020
250
330
1XB1 631
775
640
–
115
100
955
400
295
175
1090
320
555
1XB7 730
750
615
–
100
–
970
310
300
180
1105
255
345
1XB7 731
750
615
–
100
115
970
310
300
180
1105
255
345
1XB7 740
840
655
60
100
150
1010
365
300
235
1190
340
425
GT640
695
595
–
100
110
950
225
300
155
1050
170
310
1XB1 621
745
625
–
100
150
980
305
300
165
1100
250
330
1XB1 631
815
680
–
100
100
1035
400
300
175
1170
320
555
355
4/24
4, 6
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors –
enclosed version
5/2
5
5/2
5/2
5/4
5/6
5/8
5/8
5/10
5/12
5/14
5/14
5/16
5/18
5/20
5/20
5/22
5/24
5/26
5/26
5/28
5/30
1LQ1/1MQ1 motors for
converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency – low noise
High Efficiency – increased output
Premium Efficiency
Line voltage 500 V, 50 Hz
High Efficiency – low noise
High Efficiency – increased output
Premium Efficiency
Line voltage 690 V, 50 Hz
High Efficiency – low noise
High Efficiency – increased output
Premium Efficiency
Line voltage 460 V, 60 Hz
High Efficiency – low noise
High Efficiency – increased output
Premium Efficiency
Line voltage 575 V, 60 Hz
High Efficiency – low noise
High Efficiency – increased output
Premium Efficiency
5/32
5/32
5/32
5/33
5/34
5/35
Dimensions
1LQ1/1MQ1 motors
• Radially mounted equipment unit
• Axially mounted equipment unit
Flanges
Terminal boxes
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency – low noise
■ Selection and ordering data
5
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V
3000 rpm, 4-pole
255
342
315
Δ
100.7 812
94.7
95.2
94.7
0.89
410
6.1
2.1
1■Q1212-3AB11-1■■■
1■Q1212-3AB31-1■■■
320
429
315
Δ
100.6 1019
95.2
95.7
95.2
0.90
500
6.7
2.2
360
483
315
Δ
100.6 1146
95.4
95.9
95.5
0.90
570
7.0
2.3
1■Q1212-3AB51-1■■■
415
557
315
Δ
100.6 1321
95.7
96.1
95.7
0.91
640
7.6
2.5
1■Q1212-3AB71-1■■■
1■Q1212-3BB51-1■■■
455
610
355
Δ
100.5 1449
95.7
96.3
95.9
0.89
720
6.5
2.3
475
637
355
Δ
100.6 1513
95.7
96.3
96.0
0.89
750
5.8
2.1
1■Q1212-3BB71-1■■■
1500 rpm, 4-pole
245
329
315
Δ
50.5
1560
94.7
95.6
95.8
0.87
400
7.1
2.6
1■Q1212-3AB11-2■■■
320
429
315
Δ
50.5
2037
95.1
95.9
96.1
0.88
510
8.1
2.9
1■Q1212-3AB31-2■■■
355
476
315
Δ
50.5
2260
95.2
95.9
96.2
0.89
560
8.3
2.9
1■Q1212-3AB51-2■■■
405
543
315
Δ
50.5
2579
95.3
96.2
96.3
0.90
640
8.2
2.9
1■Q1212-3AB71-2■■■
430
577
355
Δ
50.4
2738
95.6
96.5
96.6
0.88
690
7.4
2.9
1■Q1212-3BB51-2■■■
475
637
355
Δ
50.4
3024
95.7
96.6
96.6
0.88
760
8.3
3.2
1■Q1212-3BB71-2■■■
1000 rpm, 6-pole
215
288
315
Δ
50.5
2054
94.6
95.5
95.7
0.81
380
7.5
2.4
1■Q1212-3AC11-3■■■
265
355
315
Δ
50.5
2532
94.8
95.7
95.9
0.82
460
7.6
2.4
1■Q1212-3AC31-3■■■
305
409
315
Δ
50.5
2914
94.9
95.7
96.0
0.84
510
7.5
2.3
1■Q1212-3AC51-3■■■
1■Q1212-3AC71-3■■■
340
456
315
Δ
50.4
3248
95.1
95.7
96.0
0.83
580
8.0
2.3
380
510
355
Δ
50.4
3630
95.1
96.0
95.9
0.86
630
9.1
2.7
1■Q1212-3BC51-3■■■
425
570
355
Δ
50.3
4059
95.3
96.1
95.9
0.84
720
10.1
2.4
1■Q1212-3BC71-3■■■
750 rpm, 6-pole
165
221
315
Δ
38.0
2102
93.7
94.8
95.0
0.79
300
7.4
2.6
1■Q1212-3AC11-4■■■
215
288
315
Δ
38.0
2739
93.9
95.0
95.3
0.81
380
7.1
2.4
1■Q1212-3AC31-4■■■
245
329
315
Δ
38.0
3122
93.9
95.1
95.5
0.84
415
6.8
2.2
1■Q1212-3AC51-4■■■
275
369
315
Δ
38.0
3503
94.0
95.2
95.5
0.84
465
6.8
2.1
1■Q1212-3AC71-4■■■
315
422
355
Δ
37.9
4013
94.0
95.1
95.4
0.87
520
7.6
2.5
1■Q1212-3BC51-4■■■
350
469
355
Δ
37.9
4458
94.2
95.3
95.5
0.87
570
7.9
2.2
1■Q1212-3BC71-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V
3000 rpm, 4-pole
245
329
315
Δ
100.6 780
94.7
95.1
94.6
0.89
440
6.3
2.1
1■Q1222-3AB11-1■■■
1■Q1222-3AB31-1■■■
310
416
315
Δ
100.6 987
95.2
95.7
95.2
0.90
550
7.1
2.4
355
476
315
Δ
100.5 1130
95.5
95.9
95.4
0.90
620
7.8
2.6
1■Q1222-3AB51-1■■■
375
503
315
Δ
100.7 1194
95.4
96.0
95.6
0.91
650
6.6
2.2
1■Q1222-3AB71-1■■■
445
597
355
Δ
100.4 1417
95.8
96.2
95.7
0.89
790
7.7
2.8
1■Q1222-3BB51-1■■■
465
624
355
Δ
100.5 1480
95.8
96.3
95.9
0.89
820
6.9
2.5
1■Q1222-3BB71-1■■■
1500 rpm, 4-pole
250
335
315
Δ
50.5
1592
94.9
95.7
95.8
0.85
465
7.7
2.9
1■Q1222-3AB11-2■■■
315
422
315
Δ
50.5
2006
95.1
95.9
96.1
0.88
570
8.0
2.9
1■Q1222-3AB31-2■■■
355
476
315
Δ
50.5
2260
95.3
95.9
96.2
0.89
630
8.3
3.0
1■Q1222-3AB51-2■■■
405
543
315
Δ
50.5
2579
95.4
96.3
96.4
0.89
720
8.5
2.9
1■Q1222-3AB71-2■■■
430
577
355
Δ
50.4
2738
95.6
96.5
96.6
0.88
770
7.8
3.0
1■Q1222-3BB51-2■■■
480
644
355
Δ
50.4
3059
95.9
96.6
96.6
0.87
870
8.9
3.2
1■Q1222-3BB71-2■■■
1000 rpm, 6-pole
215
288
315
Δ
50.5
2054
94.5
95.5
95.7
0.81
420
7.3
2.3
1■Q1222-3AC11-3■■■
270
362
315
Δ
50.5
2580
94.8
95.7
95.9
0.82
520
7.6
2.4
1■Q1222-3AC31-3■■■
305
409
315
Δ
50.5
2914
95.0
95.7
96.0
0.83
580
7.8
2.4
1■Q1222-3AC51-3■■■
1■Q1222-3AC71-3■■■
345
463
315
Δ
50.5
3296
95.0
95.7
96.1
0.84
650
7.4
2.2
380
510
355
Δ
50.3
3630
95.2
96.0
95.8
0.84
720
9.8
2.7
1■Q1222-3BC51-3■■■
415
557
355
Δ
50.3
3964
95.3
96.1
95.9
0.85
770
10.0
2.5
1■Q1222-3BC71-3■■■
750 rpm, 6-pole
180
241
315
Δ
38.0
2293
93.6
94.8
95.1
0.80
360
7.0
2.4
1■Q1222-3AC11-4■■■
215
288
315
Δ
38.0
2739
94.0
95.1
95.3
0.80
430
7.5
2.6
1■Q1222-3AC31-4■■■
245
329
315
Δ
38.0
3121
94.0
95.2
95.4
0.82
475
7.3
2.4
1■Q1222-3AC51-4■■■
270
362
315
Δ
38.0
3440
94.0
95.2
95.5
0.84
510
6.9
2.2
1■Q1222-3AC71-4■■■
315
422
355
Δ
37.9
4013
94.0
95.1
95.4
0.87
580
7.6
2.5
1■Q1222-3BC51-4■■■
350
469
355
Δ
37.9
4458
94.2
95.3
95.5
0.87
640
8.1
2.2
1■Q1222-3BC71-4■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC71-4■■■
Prated
5/2
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency – low noise
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1212-3AB11-1...
1.Q1212-3AB31-1...
1.Q1212-3AB51-1...
1.Q1212-3AB71-1...
1.Q1212-3BB51-1...
1.Q1212-3BB71-1...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
477
590
590
725
725
820
1.Q1212-3AB11-2...
1.Q1212-3AB31-2...
1.Q1212-3AB51-2...
1.Q1212-3AB71-2...
1.Q1212-3BB51-2...
1.Q1212-3BB71-2...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
477
590
590
725
725
820
1.Q1212-3AC11-3...
1.Q1212-3AC31-3...
1.Q1212-3AC51-3...
1.Q1212-3AC71-3...
1.Q1212-3BC51-3...
1.Q1212-3BC71-3...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
477
477
590
590
725
725
1.Q1212-3AC11-4...
1.Q1212-3AC31-4...
1.Q1212-3AC51-4...
1.Q1212-3AC71-4...
1.Q1212-3BC51-4...
1.Q1212-3BC71-4...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LE33-1AA3
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
302
477
477
477
590
590
1.Q1222-3AB11-1...
1.Q1222-3AB31-1...
1.Q1222-3AB51-1...
1.Q1222-3AB71-1...
1.Q1222-3BB51-1...
1.Q1222-3BB71-1...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE38-4AA3
477
590
725
725
820
820
1.Q1222-3AB11-2...
1.Q1222-3AB31-2...
1.Q1222-3AB51-2...
1.Q1222-3AB71-2...
1.Q1222-3BB51-2...
1.Q1222-3BB71-2...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
477
590
725
725
820
960
1.Q1222-3AC11-3...
1.Q1222-3AC31-3...
1.Q1222-3AC51-3...
1.Q1222-3AC71-3...
1.Q1222-3BC51-3...
1.Q1222-3BC71-3...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
477
590
590
725
725
820
1.Q1222-3AC11-4...
1.Q1222-3AC31-4...
1.Q1222-3AC51-4...
1.Q1222-3AC71-4...
1.Q1222-3BC51-4...
1.Q1222-3BC71-4...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
370
477
477
590
590
725
Siemens D 81.8 · 04/2014
5
5/3
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency – increased output
■ Selection and ordering data
5
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V
3000 rpm, 4-pole
280
375
315
Δ
100.7 892
94.6
95.2
94.8
0.89
450
5.6
1.9
1■Q1312-3AB11-1■■■
1■Q1312-3AB31-1■■■
355
476
315
Δ
100.7 1130
95.1
95.7
95.4
0.90
560
6.0
2.0
400
536
315
Δ
100.7 1274
95.3
95.9
95.6
0.90
630
6.3
2.1
1■Q1312-3AB51-1■■■
460
617
315
Δ
100.6 1465
95.6
96.1
95.8
0.91
710
6.8
2.2
1■Q1312-3AB71-1■■■
1■Q1312-3BB51-1■■■
495
664
355
Δ
100.6 1576
95.7
96.3
96.0
0.89
780
6.0
2.1
510
684
355
Δ
100.6 1624
95.6
96.3
96.1
0.89
810
5.4
1.9
1■Q1312-3BB71-1■■■
1500 rpm, 4-pole
265
355
315
Δ
50.6
1688
94.4
95.4
95.7
0.87
435
6.5
2.4
1■Q1312-3AB11-2■■■
345
463
315
Δ
50.5
2197
94.9
95.8
96.0
0.88
560
7.4
2.7
1■Q1312-3AB31-2■■■
380
510
315
Δ
50.5
2420
95.0
95.9
96.1
0.89
600
7.7
2.7
1■Q1312-3AB51-2■■■
435
583
315
Δ
50.5
2770
95.1
96.0
96.3
0.90
680
7.7
2.7
1■Q1312-3AB71-2■■■
470
630
355
Δ
50.5
2993
95.4
96.4
96.5
0.89
740
6.9
2.6
1■Q1312-3BB51-2■■■
515
691
355
Δ
50.4
3279
95.6
96.5
96.6
0.88
820
7.7
2.9
1■Q1312-3BB71-2■■■
1000 rpm, 6-pole
235
315
315
Δ
50.5
2246
94.2
95.3
95.5
0.81
415
6.8
2.2
1■Q1312-3AC11-3■■■
290
389
315
Δ
50.5
2771
94.5
95.5
95.7
0.83
495
7.0
2.2
1■Q1312-3AC31-3■■■
335
449
315
Δ
50.6
3201
94.6
95.6
95.9
0.84
570
6.7
2.1
1■Q1312-3AC51-3■■■
1■Q1312-3AC71-3■■■
375
503
315
Δ
50.5
3583
94.8
95.7
95.9
0.84
640
7.2
2.1
405
543
355
Δ
50.4
3870
95.0
95.9
95.9
0.86
670
8.6
2.6
1■Q1312-3BC51-3■■■
455
610
355
Δ
50.3
4346
95.2
96.0
95.9
0.85
760
9.6
2.3
1■Q1312-3BC71-3■■■
750 rpm, 6-pole
190
255
315
Δ
38.0
2420
93.0
94.3
94.8
0.80
340
6.5
2.2
1■Q1312-3AC11-4■■■
235
315
315
Δ
38.0
2994
93.4
94.7
95.1
0.82
410
6.6
2.2
1■Q1312-3AC31-4■■■
270
362
315
Δ
38.1
3441
93.4
94.7
95.2
0.84
460
6.1
2.0
1■Q1312-3AC51-4■■■
300
402
315
Δ
38.1
3823
93.6
94.9
95.3
0.84
510
6.2
1.9
1■Q1312-3AC71-4■■■
330
443
355
Δ
37.9
4204
93.8
95.0
95.3
0.87
540
7.3
2.4
1■Q1312-3BC51-4■■■
370
496
355
Δ
37.9
4713
94.0
95.2
95.4
0.87
610
7.4
2.1
1■Q1312-3BC71-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V
3000 rpm, 4-pole
275
369
315
Δ
100.7 876
94.6
95.1
94.8
0.89
495
5.6
1.9
1■Q1322-3AB11-1■■■
1■Q1322-3AB31-1■■■
350
469
315
Δ
100.7 1114
95.2
95.7
95.4
0.90
620
6.3
2.1
395
530
315
Δ
100.6 1258
95.4
95.9
95.6
0.90
700
6.9
2.3
1■Q1322-3AB51-1■■■
415
557
315
Δ
100.7 1322
95.3
95.9
95.7
0.91
720
6.0
2.0
1■Q1322-3AB71-1■■■
490
657
355
Δ
100.5 1560
95.8
96.3
95.9
0.89
870
7.0
2.5
1■Q1322-3BB51-1■■■
510
684
355
Δ
100.5 1624
95.8
96.4
96.1
0.89
900
6.3
2.3
1■Q1322-3BB71-1■■■
1500 rpm, 4-pole
270
362
315
Δ
50.5
1719
94.6
95.5
95.7
0.86
500
7.1
2.7
1■Q1322-3AB11-2■■■
340
456
315
Δ
50.5
2165
94.8
95.8
96.0
0.88
610
7.5
2.7
1■Q1322-3AB31-2■■■
385
516
315
Δ
50.5
2452
95.0
96.0
96.1
0.89
680
7.7
2.7
1■Q1322-3AB51-2■■■
445
597
315
Δ
50.5
2833
95.1
96.1
96.3
0.90
780
7.9
2.6
1■Q1322-3AB71-2■■■
475
637
355
Δ
50.5
3025
95.4
96.4
96.5
0.89
840
7.1
2.7
1■Q1322-3BB51-2■■■
535
717
355
Δ
50.4
3406
95.7
96.6
96.6
0.88
960
8.1
2.9
1■Q1322-3BB71-2■■■
1000 rpm, 6-pole
235
315
315
Δ
50.6
2246
94.2
95.2
95.5
0.82
455
6.7
2.1
1■Q1322-3AC11-3■■■
295
396
315
Δ
50.5
2819
94.5
95.5
95.8
0.83
570
6.9
2.2
1■Q1322-3AC31-3■■■
335
449
315
Δ
50.5
3201
94.6
95.7
95.9
0.83
640
7.0
2.2
1■Q1322-3AC51-3■■■
1■Q1322-3AC71-3■■■
380
510
315
Δ
50.6
3631
94.7
95.7
96.0
0.85
710
6.7
2.0
410
550
355
Δ
50.4
3917
95.1
95.9
95.8
0.85
760
9.3
2.5
1■Q1322-3BC51-3■■■
440
590
355
Δ
50.3
4203
95.2
96.0
95.9
0.85
820
9.4
2.4
1■Q1322-3BC71-3■■■
750 rpm, 6-pole
195
261
315
Δ
38.1
2486
93.2
94.5
94.9
0.80
390
6.5
2.2
1■Q1322-3AC11-4■■■
240
322
315
Δ
38.0
3059
93.5
94.7
95.1
0.81
475
6.7
2.3
1■Q1322-3AC31-4■■■
270
362
315
Δ
38.0
3440
93.6
94.8
95.2
0.83
520
6.6
2.2
1■Q1322-3AC51-4■■■
295
396
315
Δ
38.1
3759
93.6
94.8
95.3
0.84
560
6.3
2.0
1■Q1322-3AC71-4■■■
330
443
355
Δ
37.9
4204
93.9
95.0
95.3
0.87
610
7.2
2.4
1■Q1322-3BC51-4■■■
370
496
355
Δ
37.9
4714
94.1
95.2
95.4
0.87
680
7.7
2.1
1■Q1322-3BC71-4■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC71-4■■■
Prated
5/4
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency – increased output
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1312-3AB11-1...
1.Q1312-3AB31-1...
1.Q1312-3AB51-1...
1.Q1312-3AB71-1...
1.Q1312-3BB51-1...
1.Q1312-3BB71-1...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE38-4AA3
477
590
725
725
820
820
1.Q1312-3AB11-2...
1.Q1312-3AB31-2...
1.Q1312-3AB51-2...
1.Q1312-3AB71-2...
1.Q1312-3BB51-2...
1.Q1312-3BB71-2...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE38-4AA3
477
590
725
725
820
820
1.Q1312-3AC11-3...
1.Q1312-3AC31-3...
1.Q1312-3AC51-3...
1.Q1312-3AC71-3...
1.Q1312-3BC51-3...
1.Q1312-3BC71-3...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
477
590
590
725
725
820
1.Q1312-3AC11-4...
1.Q1312-3AC31-4...
1.Q1312-3AC51-4...
1.Q1312-3AC71-4...
1.Q1312-3BC51-4...
1.Q1312-3BC71-4...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-7LE33-8AA3
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
370
477
477
590
590
725
1.Q1322-3AB11-1...
1.Q1322-3AB31-1...
1.Q1322-3AB51-1...
1.Q1322-3AB71-1...
1.Q1322-3BB51-1...
1.Q1322-3BB71-1...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE41-0AA3
6SL3710-1GE41-0AA3
590
725
725
725
960
960
1.Q1322-3AB11-2...
1.Q1322-3AB31-2...
1.Q1322-3AB51-2...
1.Q1322-3AB71-2...
1.Q1322-3BB51-2...
1.Q1322-3BB71-2...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-1GE41-0AA3
590
725
725
820
960
960
1.Q1322-3AC11-3...
1.Q1322-3AC31-3...
1.Q1322-3AC51-3...
1.Q1322-3AC71-3...
1.Q1322-3BC51-3...
1.Q1322-3BC71-3...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE38-4AA3
477
590
725
725
820
820
1.Q1322-3AC11-4...
1.Q1322-3AC31-4...
1.Q1322-3AC51-4...
1.Q1322-3AC71-4...
1.Q1322-3BC51-4...
1.Q1322-3BC71-4...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
477
477
590
590
725
725
Siemens D 81.8 · 04/2014
5
5/5
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V
1500 rpm, 4-pole
5
210
282
315
Δ
50.5
1337
95.1
96.0
96.0
0.86
345
8.3
3.1
1■Q1213-3AB11-2■■■
325
436
315
Δ
50.5
2070
95.1
96.0
96.2
0.88
520
7.9
2.9
1■Q1213-3AB31-2■■■
360
483
315
Δ
50.5
2292
95.2
96.2
96.3
0.89
570
8.1
2.9
1■Q1213-3AB51-2■■■
415
557
315
Δ
50.5
2643
95.3
96.3
96.5
0.90
650
8.1
2.8
1■Q1213-3AB71-2■■■
445
597
355
Δ
50.5
2834
95.7
96.6
96.8
0.88
710
7.2
2.8
1■Q1213-3BB51-2■■■
495
664
355
Δ
50.4
3152
95.9
96.8
96.9
0.88
790
8.0
3.1
1■Q1213-3BB71-2■■■
1000 rpm, 6-pole
195
261
315
Δ
50.4
1863
94.8
95.8
95.8
0.79
350
8.1
2.6
1■Q1213-3AC11-3■■■
270
362
315
Δ
50.5
2580
94.8
95.8
96.0
0.82
465
7.4
2.4
1■Q1213-3AC31-3■■■
310
416
315
Δ
50.5
2962
94.9
95.9
96.1
0.84
520
7.3
2.3
1■Q1213-3AC51-3■■■
345
463
315
Δ
50.5
3296
95.1
96.1
96.2
0.83
590
7.8
2.2
1■Q1213-3AC71-3■■■
400
536
355
Δ
50.4
3821
95.3
96.3
96.3
0.85
660
8.7
2.6
1■Q1213-3BC51-3■■■
445
597
355
Δ
50.3
4250
95.6
96.4
96.4
0.83
760
9.6
2.3
1■Q1213-3BC71-3■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V
1500 rpm, 4-pole
225
302
315
Δ
50.4
1433
95.2
96.0
96.0
0.84
425
8.4
3.2
1■Q1223-3AB11-2■■■
320
429
315
Δ
50.5
2038
95.1
96.0
96.2
0.88
580
7.9
2.9
1■Q1223-3AB31-2■■■
365
489
315
Δ
50.5
2324
95.3
96.2
96.4
0.89
650
8.1
2.9
1■Q1223-3AB51-2■■■
420
563
315
Δ
50.5
2674
95.4
96.3
96.5
0.90
740
8.3
2.8
1■Q1223-3AB71-2■■■
445
597
355
Δ
50.4
2833
95.7
96.7
96.9
0.88
790
7.6
2.9
1■Q1223-3BB51-2■■■
505
677
355
Δ
50.4
3215
96.0
96.9
97.0
0.87
910
8.5
3.1
1■Q1223-3BB71-2■■■
1000 rpm, 6-pole
195
261
315
Δ
50.5
1863
94.8
95.7
95.9
0.80
385
7.9
2.6
1■Q1223-3AC11-3■■■
275
369
315
Δ
50.5
2627
94.8
95.8
96.0
0.82
530
7.4
2.4
1■Q1223-3AC31-3■■■
315
422
315
Δ
50.5
3010
94.9
95.9
96.1
0.83
600
7.5
2.4
1■Q1223-3AC51-3■■■
350
469
315
Δ
50.5
3344
95.0
96.1
96.3
0.84
660
7.2
2.2
1■Q1223-3AC71-3■■■
400
536
355
Δ
50.3
3821
95.4
96.3
96.3
0.83
760
9.3
2.6
1■Q1223-3BC51-3■■■
435
583
355
Δ
50.3
4155
95.6
96.4
96.4
0.84
820
9.4
2.4
1■Q1223-3BC71-3■■■
For versions, see Article No. supplements and special versions
5/6
Siemens D 81.8 · 04/2014
1■M1223-3AC71-3■■■
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1213-3AB11-2...
1310
1360
3.5
79
94.5
3000
1XB7 730
6SL3710-7LE33-8AA3
370
1.Q1213-3AB31-2...
1490
1540
4.4
79
94.5
3000
1XB7 731
6SL3710-7LE36-1AA3
590
1.Q1213-3AB51-2...
1670
1720
5
79
94.5
3000
1XB7 731
6SL3710-7LE36-1AA3
590
1.Q1213-3AB71-2...
1830
1880
5.8
79
94.5
3000
1XB7 740
6SL3710-7LE37-5AA3
725
1.Q1213-3BB51-2...
2300
2350
8.3
79
95
2600
1XB7 740
6SL3710-7LE37-5AA3
725
1.Q1213-3BB71-2...
2420
2480
8.9
79
95
2600
1XB7 740
6SL3710-7LE38-4AA3
820
1.Q1213-3AC11-3...
1340
1390
5.9
79
94.5
2600
1XB7 730
6SL3710-7LE33-8AA3
370
1.Q1213-3AC31-3...
1520
1570
7.2
79
94.5
2600
1XB7 731
6SL3710-7LE35-0AA3
477
1.Q1213-3AC51-3...
1700
1750
8.3
79
94.5
2600
1XB7 731
6SL3710-7LE36-1AA3
590
1.Q1213-3AC71-3...
1810
1860
9.1
79
94.5
2600
1XB7 731
6SL3710-7LE36-1AA3
590
1.Q1213-3BC51-3...
2290
2350
14.5
79
95
2500
1XB7 740
6SL3710-7LE37-5AA3
725
1.Q1213-3BC71-3...
2440
2490
16
79
95
2500
1XB7 740
6SL3710-7LE38-4AA3
820
1.Q1223-3AB11-2...
1310
1360
3.5
79
94.5
3000
1XB7 731
6SL3710-1GE35-0AA3
477
1.Q1223-3AB31-2...
1490
1540
4.4
79
94.5
3000
1XB7 731
6SL3710-1GE36-1AA3
590
1.Q1223-3AB51-2...
1670
1720
5
79
94.5
3000
1XB7 740
6SL3710-1GE37-5AA3
725
1.Q1223-3AB71-2...
1830
1880
5.8
79
94.5
3000
1XB7 740
6SL3710-1GE38-4AA3
820
1.Q1223-3BB51-2...
2300
2350
8.3
79
95
2600
1XB7 740
6SL3710-1GE38-4AA3
820
1.Q1223-3BB71-2...
2420
2480
8.9
79
95
2600
1XB7 740
6SL3710-1GE41-0AA3
960
1.Q1223-3AC11-3...
1340
1390
5.9
79
94.5
2600
1XB7 731
6SL3710-1GE35-0AA3
477
1.Q1223-3AC31-3...
1520
1570
7.2
79
94.5
2600
1XB7 731
6SL3710-1GE36-1AA3
590
1.Q1223-3AC51-3...
1700
1750
8.3
79
94.5
2600
1XB7 740
6SL3710-1GE37-5AA3
725
1.Q1223-3AC71-3...
1810
1860
9.1
79
94.5
2600
1XB7 740
6SL3710-1GE37-5AA3
725
1.Q1223-3BC51-3...
2290
2350
14.5
79
95
2500
1XB7 740
6SL3710-1GE38-4AA3
820
1.Q1223-3BC71-3...
2440
2490
16
79
95
2500
1XB7 740
6SL3710-1GE38-4AA3
820
Siemens D 81.8 · 04/2014
5
5/7
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency – low noise
■ Selection and ordering data
5
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V
3000 rpm, 4-pole
240
322
315
Δ
100.6 764
94.6
95.0
94.5
0.89
315
6.8
2.3
1■Q1212-3AB12-1■■■
1■Q1212-3AB32-1■■■
305
409
315
Δ
100.5 971
95.2
95.6
95.0
0.89
400
8.2
2.8
340
456
315
Δ
100.5 1082
95.4
95.8
95.3
0.90
440
8.5
2.8
1■Q1212-3AB52-1■■■
365
489
315
Δ
100.6 1162
95.4
95.9
95.5
0.91
465
7.1
2.3
1■Q1212-3AB72-1■■■
1■Q1212-3BB52-1■■■
435
583
355
Δ
100.5 1385
95.7
96.1
95.7
0.89
560
7.5
2.7
455
610
355
Δ
100.5 1449
95.7
96.2
95.9
0.89
590
6.7
2.4
1■Q1212-3BB72-1■■■
1500 rpm, 4-pole
225
302
315
Δ
50.5
1433
94.6
95.5
95.6
0.87
300
7.6
2.8
1■Q1212-3AB12-2■■■
285
382
315
Δ
50.5
1815
94.9
95.8
96.0
0.88
375
8.0
2.9
1■Q1212-3AB32-2■■■
330
443
315
Δ
50.4
2101
95.2
95.9
96.1
0.88
435
8.8
3.2
1■Q1212-3AB52-2■■■
390
523
315
Δ
50.4
2483
95.5
96.3
96.3
0.87
520
9.8
3.0
1■Q1212-3AB72-2■■■
410
550
355
Δ
50.4
2612
95.7
96.5
96.4
0.86
550
9.0
3.6
1■Q1212-3BB52-2■■■
445
597
355
Δ
50.3
2835
95.8
96.5
96.4
0.85
600
9.9
3.5
1■Q1212-3BB72-2■■■
1000 rpm, 6-pole
205
275
315
Δ
50.5
1959
94.6
95.5
95.6
0.81
295
7.9
2.5
1■Q1212-3AC12-3■■■
245
329
315
Δ
50.4
2341
94.8
95.7
95.7
0.82
345
8.2
2.6
1■Q1212-3AC32-3■■■
280
375
315
Δ
50.5
2675
94.7
95.7
95.8
0.84
385
7.7
2.4
1■Q1212-3AC52-3■■■
1■Q1212-3AC72-3■■■
305
409
315
Δ
50.4
2914
94.9
95.7
95.9
0.84
420
8.0
2.5
350
469
355
Δ
50.3
3343
95.1
95.7
95.7
0.85
475
10.0
3.0
1■Q1212-3BC52-3■■■
385
516
355
Δ
50.3
3677
95.2
95.9
95.7
0.84
530
10.6
2.7
1■Q1212-3BC72-3■■■
750 rpm, 6-pole
160
215
315
Δ
37.9
2038
93.5
94.6
94.8
0.78
240
7.6
2.6
1■Q1212-3AC12-4■■■
195
261
315
Δ
37.9
2484
93.8
94.9
95.1
0.80
285
7.8
2.6
1■Q1212-3AC32-4■■■
220
295
315
Δ
38.0
2803
93.7
94.9
95.3
0.84
305
7.3
2.4
1■Q1212-3AC52-4■■■
250
335
315
Δ
38.0
3185
93.9
95.1
95.3
0.83
350
7.5
2.3
1■Q1212-3AC72-4■■■
290
389
355
Δ
37.8
3694
94.2
95.2
95.2
0.85
400
9.1
2.7
1■Q1212-3BC52-4■■■
320
429
355
Δ
37.9
4076
94.1
95.1
95.3
0.87
430
8.4
2.4
1■Q1212-3BC72-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V
3000 rpm, 4-pole
255
342
315
Δ
100.6 812
94.8
95.2
94.7
0.89
360
6.5
2.2
1■Q1222-3AB12-1■■■
1■Q1222-3AB32-1■■■
320
429
315
Δ
100.6 1019
95.2
95.7
95.2
0.90
445
6.7
2.2
355
476
315
Δ
100.6 1130
95.4
95.9
95.5
0.90
495
6.9
2.3
1■Q1222-3AB52-1■■■
410
550
315
Δ
100.6 1305
95.6
96.1
95.7
0.91
560
7.2
2.3
1■Q1222-3AB72-1■■■
445
597
355
Δ
100.6 1417
95.6
96.2
95.9
0.89
630
6.1
2.2
1■Q1222-3BB52-1■■■
485
650
355
Δ
100.5 1544
95.8
96.3
95.9
0.89
680
7.4
2.6
1■Q1222-3BB72-1■■■
1500 rpm, 4-pole
245
329
315
Δ
50.6
1560
94.6
95.6
95.8
0.87
355
6.8
2.5
1■Q1222-3AB12-2■■■
325
436
315
Δ
50.5
2069
95.2
95.9
96.1
0.87
470
8.2
3.0
1■Q1222-3AB32-2■■■
360
483
315
Δ
50.5
2292
95.3
95.9
96.2
0.89
510
8.3
3.0
1■Q1222-3AB52-2■■■
405
543
315
Δ
50.5
2579
95.3
96.2
96.3
0.90
560
8.3
2.9
1■Q1222-3AB72-2■■■
450
603
355
Δ
50.4
2868
95.8
96.6
96.5
0.86
650
9.0
3.5
1■Q1222-3BB52-2■■■
475
637
355
Δ
50.4
3024
95.7
96.6
96.6
0.88
670
8.1
3.1
1■Q1222-3BB72-2■■■
1000 rpm, 6-pole
210
282
315
Δ
50.5
2007
94.4
95.5
95.7
0.82
325
7.0
2.2
1■Q1222-3AC12-3■■■
270
362
315
Δ
50.5
2579
94.9
95.7
95.9
0.82
415
7.7
2.5
1■Q1222-3AC32-3■■■
305
409
315
Δ
50.5
2914
94.9
95.7
96.0
0.84
460
7.4
2.4
1■Q1222-3AC52-3■■■
1■Q1222-3AC72-3■■■
340
456
315
Δ
50.5
3248
95.1
95.7
96.1
0.83
510
7.8
2.3
380
510
355
Δ
50.4
3630
95.1
95.9
95.9
0.86
550
9.0
2.7
1■Q1222-3BC52-3■■■
425
570
355
Δ
50.3
4060
95.3
96.1
95.9
0.85
630
9.5
2.4
1■Q1222-3BC72-3■■■
750 rpm, 6-pole
170
228
315
Δ
38.0
2166
93.6
94.8
95.0
0.80
270
7.1
2.4
1■Q1222-3AC12-4■■■
215
288
315
Δ
38.0
2739
93.9
95.0
95.3
0.81
335
7.1
2.4
1■Q1222-3AC32-4■■■
240
322
315
Δ
38.0
3058
93.8
95.0
95.4
0.84
360
6.7
2.2
1■Q1222-3AC52-4■■■
265
355
315
Δ
38.0
3376
93.9
95.1
95.5
0.84
400
6.6
2.2
1■Q1222-3AC72-4■■■
320
429
355
Δ
37.9
4076
94.1
95.2
95.4
0.86
470
7.8
2.4
1■Q1222-3BC52-4■■■
350
469
355
Δ
37.9
4458
94.2
95.3
95.5
0.87
510
8.0
2.2
1■Q1222-3BC72-4■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC72-4■■■
Prated
5/8
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency – low noise
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1212-3AB12-1...
1.Q1212-3AB32-1...
1.Q1212-3AB52-1...
1.Q1212-3AB72-1...
1.Q1212-3BB52-1...
1.Q1212-3BB72-1...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
320
400
452
560
560
710
1.Q1212-3AB12-2...
1.Q1212-3AB32-2...
1.Q1212-3AB52-2...
1.Q1212-3AB72-2...
1.Q1212-3BB52-2...
1.Q1212-3BB72-2...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
320
400
452
560
560
710
1.Q1212-3AC12-3...
1.Q1212-3AC32-3...
1.Q1212-3AC52-3...
1.Q1212-3AC72-3...
1.Q1212-3BC52-3...
1.Q1212-3BC72-3...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
320
400
400
452
560
560
1.Q1212-3AC12-4...
1.Q1212-3AC32-4...
1.Q1212-3AC52-4...
1.Q1212-3AC72-4...
1.Q1212-3BC52-4...
1.Q1212-3BC72-4...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
250
320
320
400
400
452
1.Q1222-3AB12-1...
1.Q1222-3AB32-1...
1.Q1222-3AB52-1...
1.Q1222-3AB72-1...
1.Q1222-3BB52-1...
1.Q1222-3BB72-1...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
370
477
590
590
725
725
1.Q1222-3AB12-2...
1.Q1222-3AB32-2...
1.Q1222-3AB52-2...
1.Q1222-3AB72-2...
1.Q1222-3BB52-2...
1.Q1222-3BB72-2...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
370
477
590
590
725
725
1.Q1222-3AC12-3...
1.Q1222-3AC32-3...
1.Q1222-3AC52-3...
1.Q1222-3AC72-3...
1.Q1222-3BC52-3...
1.Q1222-3BC72-3...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
370
477
477
590
590
725
1.Q1222-3AC12-4...
1.Q1222-3AC32-4...
1.Q1222-3AC52-4...
1.Q1222-3AC72-4...
1.Q1222-3BC52-4...
1.Q1222-3BC72-4...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GE33-1AA3
6SL3710-1GE33-8AA3
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
302
370
370
477
477
590
Siemens D 81.8 · 04/2014
5
5/9
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency – increased output
■ Selection and ordering data
5
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V
3000 rpm, 4-pole
265
355
315
Δ
100.7 844
94.5
95.0
94.6
0.89
350
6.1
2.1
1■Q1312-3AB12-1■■■
1■Q1312-3AB32-1■■■
345
463
315
Δ
100.6 1098
95.2
95.7
95.2
0.90
445
7.3
2.4
380
510
315
Δ
100.5 1210
95.4
95.8
95.4
0.90
490
7.6
2.5
1■Q1312-3AB52-1■■■
405
543
315
Δ
100.7 1290
95.2
95.8
95.6
0.91
520
6.4
2.1
1■Q1312-3AB72-1■■■
1■Q1312-3BB52-1■■■
475
637
355
Δ
100.5 1512
95.7
96.2
95.8
0.89
620
6.8
2.4
500
671
355
Δ
100.6 1592
95.6
96.3
96.0
0.89
650
6.1
2.2
1■Q1312-3BB72-1■■■
1500 rpm, 4-pole
245
329
315
Δ
50.5
1560
94.3
95.3
95.5
0.87
330
6.9
2.6
1■Q1312-3AB12-2■■■
305
409
315
Δ
50.5
1942
94.7
95.6
95.9
0.89
400
7.5
2.7
1■Q1312-3AB32-2■■■
360
483
315
Δ
50.5
2292
95.0
95.9
96.0
0.89
470
8.1
2.9
1■Q1312-3AB52-2■■■
425
570
315
Δ
50.4
2706
95.3
96.1
96.2
0.88
560
9.1
2.7
1■Q1312-3AB72-2■■■
460
617
355
Δ
50.4
2929
95.5
96.4
96.4
0.87
610
8.1
3.2
1■Q1312-3BB52-2■■■
505
677
355
Δ
50.4
3218
95.7
96.5
96.5
0.87
670
8.9
3.1
1■Q1312-3BB72-2■■■
1000 rpm, 6-pole
220
295
315
Δ
50.5
2102
94.3
95.3
95.5
0.81
315
7.4
2.3
1■Q1312-3AC12-3■■■
270
362
315
Δ
50.5
2580
94.4
95.4
95.6
0.82
385
7.4
2.3
1■Q1312-3AC32-3■■■
305
409
315
Δ
50.5
2915
94.4
95.5
95.7
0.84
420
7.1
2.2
1■Q1312-3AC52-3■■■
1■Q1312-3AC72-3■■■
340
456
315
Δ
50.5
3249
94.5
95.6
95.8
0.84
470
7.2
2.2
375
503
355
Δ
50.3
3583
94.9
95.7
95.7
0.85
510
9.3
2.8
1■Q1312-3BC52-3■■■
410
550
355
Δ
50.3
3916
95.1
95.9
95.7
0.85
560
10.1
2.5
1■Q1312-3BC72-3■■■
750 rpm, 6-pole
175
235
315
Δ
38.0
2230
93.0
94.3
94.6
0.79
260
7.0
2.4
1■Q1312-3AC12-4■■■
215
288
315
Δ
38.0
2739
93.3
94.6
94.9
0.81
310
7.1
2.4
1■Q1312-3AC32-4■■■
240
322
315
Δ
38.0
3058
93.2
94.6
95.0
0.84
335
6.6
2.2
1■Q1312-3AC52-4■■■
275
369
315
Δ
38.0
3504
93.5
94.7
95.1
0.84
385
6.8
2.1
1■Q1312-3AC72-4■■■
315
422
355
Δ
37.9
4012
94.0
95.0
95.2
0.85
435
8.3
2.5
1■Q1312-3BC52-4■■■
335
449
355
Δ
37.9
4268
93.9
95.0
95.3
0.87
450
8.0
2.3
1■Q1312-3BC72-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V
3000 rpm, 4-pole
290
389
315
Δ
100.7 923
94.7
95.2
94.9
0.89
410
5.7
1.9
1■Q1322-3AB12-1■■■
1■Q1322-3AB32-1■■■
355
476
315
Δ
100.7 1130
95.1
95.6
95.4
0.90
495
6.0
2.0
395
530
315
Δ
100.7 1258
95.3
95.9
95.6
0.90
550
6.2
2.1
1■Q1322-3AB52-1■■■
450
603
315
Δ
100.7 1433
95.5
96.1
95.8
0.91
620
6.5
2.1
1■Q1322-3AB72-1■■■
485
650
355
Δ
100.6 1544
95.6
96.3
96.0
0.89
680
5.7
2.0
1■Q1322-3BB52-1■■■
535
717
355
Δ
100.5 1703
95.8
96.4
96.1
0.89
750
6.7
2.4
1■Q1322-3BB72-1■■■
1500 rpm, 4-pole
255
342
315
Δ
50.6
1624
94.4
95.4
95.7
0.88
365
6.6
2.4
1■Q1322-3AB12-2■■■
350
469
315
Δ
50.5
2228
95.0
95.9
96.0
0.87
500
7.7
2.8
1■Q1322-3AB32-2■■■
390
523
315
Δ
50.5
2483
95.0
96.0
96.1
0.89
550
7.7
2.8
1■Q1322-3AB52-2■■■
435
583
315
Δ
50.5
2770
95.1
96.0
96.2
0.90
610
7.7
2.7
1■Q1322-3AB72-2■■■
505
677
355
Δ
50.4
3215
95.7
96.5
96.5
0.87
720
8.1
3.1
1■Q1322-3BB52-2■■■
530
711
355
Δ
50.5
3375
95.5
96.5
96.6
0.89
740
7.4
2.8
1■Q1322-3BB72-2■■■
1000 rpm, 6-pole
230
308
315
Δ
50.6
2198
94.0
95.2
95.5
0.82
355
6.4
2.0
1■Q1322-3AC12-3■■■
295
396
315
Δ
50.5
2819
94.5
95.6
95.8
0.82
455
7.0
2.2
1■Q1322-3AC32-3■■■
335
449
315
Δ
50.5
3201
94.5
95.6
95.9
0.84
500
6.8
2.1
1■Q1322-3AC52-3■■■
1■Q1322-3AC72-3■■■
375
503
315
Δ
50.5
3583
94.8
95.7
95.9
0.84
560
7.1
2.1
405
543
355
Δ
50.4
3870
95.0
95.9
95.9
0.86
590
8.4
2.6
1■Q1322-3BC52-3■■■
455
610
355
Δ
50.4
4347
95.2
96.0
95.9
0.86
660
9.1
2.3
1■Q1322-3BC72-3■■■
750 rpm, 6-pole
190
255
315
Δ
38.1
2420
93.0
94.3
94.8
0.81
300
6.4
2.2
1■Q1322-3AC12-4■■■
235
315
315
Δ
38.0
2994
93.4
94.7
95.1
0.82
365
6.5
2.2
1■Q1322-3AC32-4■■■
265
355
315
Δ
38.1
3377
93.3
94.6
95.2
0.84
400
6.0
2.0
1■Q1322-3AC52-4■■■
290
389
315
Δ
38.1
3695
93.4
94.7
95.3
0.85
435
6.0
2.0
1■Q1322-3AC72-4■■■
335
449
355
Δ
37.9
4267
94.0
95.1
95.4
0.86
495
7.4
2.3
1■Q1322-3BC52-4■■■
370
496
355
Δ
37.9
4713
94.1
95.2
95.4
0.87
540
7.6
2.1
1■Q1322-3BC72-4■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC72-4■■■
Prated
5/10
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency – increased output
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1312-3AB12-1...
1.Q1312-3AB32-1...
1.Q1312-3AB52-1...
1.Q1312-3AB72-1...
1.Q1312-3BB52-1...
1.Q1312-3BB72-1...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
400
452
560
560
710
710
1.Q1312-3AB12-2...
1.Q1312-3AB32-2...
1.Q1312-3AB52-2...
1.Q1312-3AB72-2...
1.Q1312-3BB52-2...
1.Q1312-3BB72-2...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
400
400
560
560
710
710
1.Q1312-3AC12-3...
1.Q1312-3AC32-3...
1.Q1312-3AC52-3...
1.Q1312-3AC72-3...
1.Q1312-3BC52-3...
1.Q1312-3BC72-3...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
320
400
452
560
560
560
1.Q1312-3AC12-4...
1.Q1312-3AC32-4...
1.Q1312-3AC52-4...
1.Q1312-3AC72-4...
1.Q1312-3BC52-4...
1.Q1312-3BC72-4...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG34-7AA3
320
320
400
400
452
452
1.Q1322-3AB12-1...
1.Q1322-3AB32-1...
1.Q1322-3AB52-1...
1.Q1322-3AB72-1...
1.Q1322-3BB52-1...
1.Q1322-3BB72-1...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
477
590
590
725
725
820
1.Q1322-3AB12-2...
1.Q1322-3AB32-2...
1.Q1322-3AB52-2...
1.Q1322-3AB72-2...
1.Q1322-3BB52-2...
1.Q1322-3BB72-2...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE33-8AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
370
590
590
725
725
820
1.Q1322-3AC12-3...
1.Q1322-3AC32-3...
1.Q1322-3AC52-3...
1.Q1322-3AC72-3...
1.Q1322-3BC52-3...
1.Q1322-3BC72-3...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
370
477
590
590
590
725
1.Q1322-3AC12-4...
1.Q1322-3AC32-4...
1.Q1322-3AC52-4...
1.Q1322-3AC72-4...
1.Q1322-3BC52-4...
1.Q1322-3BC72-4...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GE33-1AA3
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
302
370
477
477
590
590
Siemens D 81.8 · 04/2014
5
5/11
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V
1500 rpm, 4-pole
5
180
241
315
Δ
50.4
1146
95.2
95.9
95.9
0.84
250
9.2
3.5
1■Q1213-3AB12-2■■■
260
349
315
Δ
50.4
1655
95.1
96.0
96.1
0.88
340
8.7
3.1
1■Q1213-3AB32-2■■■
335
449
315
Δ
50.5
2133
95.2
96.1
96.2
0.88
440
8.6
3.1
1■Q1213-3AB52-2■■■
400
536
315
Δ
50.4
2547
95.5
96.3
96.4
0.87
530
9.6
2.9
1■Q1213-3AB72-2■■■
420
563
355
Δ
50.4
2674
95.9
96.7
96.8
0.86
560
8.9
3.5
1■Q1213-3BB52-2■■■
475
637
355
Δ
50.3
3026
96.0
96.8
96.8
0.85
640
9.3
3.3
1■Q1213-3BB72-2■■■
1000 rpm, 6-pole
180
241
315
Δ
50.4
1719
94.9
95.8
95.8
0.79
265
8.7
2.9
1■Q1213-3AC12-3■■■
245
329
315
Δ
50.4
2341
94.8
95.8
95.9
0.81
350
8.1
2.6
1■Q1213-3AC32-3■■■
285
382
315
Δ
50.5
2723
94.7
95.8
96.0
0.84
395
7.5
2.4
1■Q1213-3AC52-3■■■
315
422
315
Δ
50.5
3009
94.9
95.9
96.1
0.84
435
7.7
2.4
1■Q1213-3AC72-3■■■
365
489
355
Δ
50.3
3487
95.3
96.2
96.2
0.84
500
9.5
2.8
1■Q1213-3BC52-3■■■
405
543
355
Δ
50.3
3868
95.5
96.3
96.3
0.83
560
10.0
2.6
1■Q1213-3BC72-3■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V
1500 rpm, 4-pole
205
275
315
Δ
50.5
1305
95.1
96.0
96.0
0.86
300
8.0
3.0
1■Q1223-3AB12-2■■■
330
443
315
Δ
50.5
2101
95.2
96.1
96.2
0.87
475
8.1
3.0
1■Q1223-3AB32-2■■■
365
489
315
Δ
50.5
2324
95.3
96.2
96.4
0.88
520
8.2
3.0
1■Q1223-3AB52-2■■■
415
557
315
Δ
50.5
2642
95.3
96.2
96.5
0.90
580
8.0
2.8
1■Q1223-3AB72-2■■■
475
637
355
Δ
50.4
3024
96.0
96.8
96.9
0.86
690
8.5
3.3
1■Q1223-3BB52-2■■■
495
664
355
Δ
50.4
3152
95.8
96.8
96.9
0.88
700
7.8
3.0
1■Q1223-3BB72-2■■■
1000 rpm, 6-pole
190
255
315
Δ
50.5
1816
94.8
95.8
95.9
0.81
295
7.7
2.5
1■Q1223-3AC12-3■■■
275
369
315
Δ
50.5
2627
94.8
95.8
96.0
0.82
420
7.6
2.4
1■Q1223-3AC32-3■■■
310
416
315
Δ
50.5
2962
94.9
95.9
96.1
0.83
470
7.2
2.3
1■Q1223-3AC52-3■■■
350
469
315
Δ
50.5
3344
95.1
96.0
96.2
0.83
530
7.5
2.2
1■Q1223-3AC72-3■■■
395
530
355
Δ
50.4
3773
95.3
96.2
96.3
0.85
580
8.5
2.6
1■Q1223-3BC52-3■■■
445
597
355
Δ
50.4
4251
95.5
96.4
96.4
0.85
650
9.2
2.3
1■Q1223-3BC72-3■■■
For versions, see Article No. supplements and special versions
5/12
Siemens D 81.8 · 04/2014
1■M1223-3AC72-3■■■
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1213-3AB12-2...
1310
1360
3.5
79
94.5
3000
1XB7 730
6SL3710-7LG32-6AA3
250
1.Q1213-3AB32-2...
1490
1540
4.4
79
94.5
3000
1XB7 730
6SL3710-7LG34-1AA3
400
1.Q1213-3AB52-2...
1670
1720
5
79
94.5
3000
1XB7 731
6SL3710-7LG34-7AA3
452
1.Q1213-3AB72-2...
1830
1880
5.8
79
94.5
3000
1XB7 731
6SL3710-7LG35-8AA3
560
1.Q1213-3BB52-2...
2300
2350
8.3
79
95
2600
1XB7 731
6SL3710-7LG35-8AA3
560
1.Q1213-3BB72-2...
2420
2480
8.9
79
95
2600
1XB7 740
6SL3710-7LG37-4AA3
710
1.Q1213-3AC12-3...
1340
1390
5.9
79
94.5
2600
1XB7 730
6SL3710-7LG33-3AA3
320
1.Q1213-3AC32-3...
1520
1570
7.2
79
94.5
2600
1XB7 730
6SL3710-7LG34-1AA3
400
1.Q1213-3AC52-3...
1700
1750
8.3
79
94.5
2600
1XB7 731
6SL3710-7LG34-1AA3
400
1.Q1213-3AC72-3...
1810
1860
9.1
79
94.5
2600
1XB7 731
6SL3710-7LG34-7AA3
452
1.Q1213-3BC52-3...
2290
2350
14.5
79
95
2500
1XB7 731
6SL3710-7LG35-8AA3
560
1.Q1213-3BC72-3...
2440
2490
16
79
95
2500
1XB7 731
6SL3710-7LG35-8AA3
560
1.Q1223-3AB12-2...
1310
1360
3.5
79
94.5
3000
1XB7 730
6SL3710-1GE33-1AA3
302
1.Q1223-3AB32-2...
1490
1540
4.4
79
94.5
3000
1XB7 731
6SL3710-1GE35-0AA3
477
1.Q1223-3AB52-2...
1670
1720
5
79
94.5
3000
1XB7 731
6SL3710-1GE36-1AA3
590
1.Q1223-3AB72-2...
1830
1880
5.8
79
94.5
3000
1XB7 731
6SL3710-1GE36-1AA3
590
1.Q1223-3BB52-2...
2300
2350
8.3
79
95
2600
1XB7 740
6SL3710-1GE37-5AA3
725
1.Q1223-3BB72-2...
2420
2480
8.9
79
95
2600
1XB7 740
6SL3710-1GE37-5AA3
725
1.Q1223-3AC12-3...
1340
1390
5.9
79
94.5
2600
1XB7 730
6SL3710-1GE33-1AA3
302
1.Q1223-3AC32-3...
1520
1570
7.2
79
94.5
2600
1XB7 731
6SL3710-1GE35-0AA3
477
1.Q1223-3AC52-3...
1700
1750
8.3
79
94.5
2600
1XB7 731
6SL3710-1GE35-0AA3
477
1.Q1223-3AC72-3...
1810
1860
9.1
79
94.5
2600
1XB7 731
6SL3710-1GE36-1AA3
590
1.Q1223-3BC52-3...
2290
2350
14.5
79
95
2500
1XB7 731
6SL3710-1GE36-1AA3
590
1.Q1223-3BC72-3...
2440
2490
16
79
95
2500
1XB7 740
6SL3710-1GE37-5AA3
725
Siemens D 81.8 · 04/2014
5
5/13
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency – low noise
■ Selection and ordering data
5
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V
3000 rpm, 4-pole
240
322
315
Δ
100.6 764
94.6
95.0
94.5
0.89
225
6.6
2.2
1■Q1212-3AB13-1■■■
1■Q1212-3AB33-1■■■
310
416
315
Δ
100.5 987
95.2
95.6
95.1
0.89
290
7.5
2.6
350
469
315
Δ
100.5 1114
95.4
95.8
95.3
0.90
320
8.7
2.9
1■Q1212-3AB53-1■■■
400
536
315
Δ
100.5 1273
95.6
96.0
95.6
0.90
365
8.2
2.7
1■Q1212-3AB73-1■■■
1■Q1212-3BB53-1■■■
450
603
355
Δ
100.5 1433
95.6
96.2
95.8
0.89
415
7.0
2.5
470
630
355
Δ
100.5 1497
95.6
96.2
95.9
0.89
435
6.2
2.2
1■Q1212-3BB73-1■■■
1500 rpm, 4-pole
215
288
315
Δ
50.5
1369
94.8
95.6
95.6
0.86
205
8.3
3.0
1■Q1212-3AB13-2■■■
290
389
315
Δ
50.4
1846
95.1
95.9
95.9
0.86
280
8.8
3.2
1■Q1212-3AB33-2■■■
335
449
315
Δ
50.4
2133
95.3
95.9
96.1
0.88
315
9.2
3.3
1■Q1212-3AB53-2■■■
385
516
315
Δ
50.4
2451
95.4
96.2
96.2
0.88
360
9.5
3.0
1■Q1212-3AB73-2■■■
410
550
355
Δ
50.4
2610
95.7
96.5
96.5
0.87
385
8.7
3.4
1■Q1212-3BB53-2■■■
440
590
355
Δ
50.4
2801
95.7
96.5
96.5
0.87
415
8.9
3.4
1■Q1212-3BB73-2■■■
1000 rpm, 6-pole
195
261
315
Y
50.4
1863
94.5
95.4
95.5
0.80
200
8.1
2.6
1■Q1212-3AC13-3■■■
245
329
315
Y
50.4
2341
94.7
95.6
95.7
0.82
245
8.1
2.5
1■Q1212-3AC33-3■■■
280
375
315
Y
50.5
2675
94.8
95.7
95.9
0.84
280
7.8
2.5
1■Q1212-3AC53-3■■■
1■Q1212-3AC73-3■■■
315
422
315
Δ
50.4
3009
95.0
95.7
96.0
0.84
310
8.0
2.5
345
463
355
Δ
50.3
3295
95.0
95.7
95.7
0.85
335
10.0
3.0
1■Q1212-3BC53-3■■■
385
516
355
Δ
50.3
3677
95.2
95.9
95.7
0.84
380
10.6
2.7
1■Q1212-3BC73-3■■■
750 rpm, 6-pole
155
208
315
Y
37.9
1975
93.5
94.6
94.8
0.79
164
7.7
2.6
1■Q1212-3AC13-4■■■
200
268
315
Y
38.0
2548
93.8
94.9
95.2
0.81
205
7.5
2.5
1■Q1212-3AC33-4■■■
225
302
315
Δ
38.0
2867
93.8
95.0
95.3
0.83
225
7.3
2.4
1■Q1212-3AC53-4■■■
255
342
315
Δ
38.0
3249
93.9
95.1
95.4
0.84
250
7.1
2.3
1■Q1212-3AC73-4■■■
295
396
355
Y
37.9
3758
94.1
95.1
95.2
0.85
290
8.7
2.6
1■Q1212-3BC53-4■■■
330
443
355
Δ
37.8
4204
94.3
95.3
95.3
0.85
320
9.0
2.4
1■Q1212-3BC73-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V
3000 rpm, 4-pole
240
322
315
Δ
100.6 764
94.7
95.0
94.5
0.88
250
6.9
2.4
1■Q1222-3AB13-1■■■
1■Q1222-3AB33-1■■■
300
402
315
Δ
100.5 955
95.1
95.5
95.0
0.90
305
7.6
2.5
340
456
315
Δ
100.5 1082
95.4
95.8
95.3
0.90
345
8.8
2.9
1■Q1222-3AB53-1■■■
390
523
315
Δ
100.5 1242
95.6
96.0
95.6
0.90
395
8.5
2.8
1■Q1222-3AB73-1■■■
420
563
355
Δ
100.4 1337
95.6
96.1
95.6
0.89
430
7.5
2.7
1■Q1222-3BB53-1■■■
440
590
355
Δ
100.5 1401
95.6
96.2
95.8
0.89
450
6.7
2.4
1■Q1222-3BB73-1■■■
1500 rpm, 4-pole
230
308
315
Δ
50.5
1464
94.7
95.6
95.7
0.86
245
7.7
2.9
1■Q1222-3AB13-2■■■
290
389
315
Δ
50.5
1846
95.0
95.9
96.0
0.88
300
8.3
3.0
1■Q1222-3AB33-2■■■
325
436
315
Δ
50.4
2069
95.2
95.9
96.1
0.88
335
8.8
3.2
1■Q1222-3AB53-2■■■
385
516
315
Δ
50.4
2451
95.4
96.2
96.3
0.89
395
9.3
3.0
1■Q1222-3AB73-2■■■
400
536
355
Δ
50.3
2548
95.8
96.5
96.4
0.84
430
9.9
3.9
1■Q1222-3BB53-2■■■
430
577
355
Δ
50.4
2738
95.7
96.5
96.5
0.87
450
8.8
3.4
1■Q1222-3BB73-2■■■
1000 rpm, 6-pole
195
261
315
Y
50.5
1863
94.5
95.4
95.5
0.80
225
7.8
2.5
1■Q1222-3AC13-3■■■
245
329
315
Δ
50.4
2341
94.7
95.6
95.7
0.82
275
8.1
2.6
1■Q1222-3AC33-3■■■
285
382
315
Δ
50.5
2723
94.9
95.7
95.9
0.84
310
7.9
2.5
1■Q1222-3AC53-3■■■
1■Q1222-3AC73-3■■■
310
416
315
Δ
50.4
2961
95.0
95.7
95.9
0.83
340
8.5
2.5
345
463
355
Δ
50.3
3295
95.0
95.7
95.7
0.85
370
9.7
3.0
1■Q1222-3BC53-3■■■
365
489
355
Δ
50.3
3486
95.3
95.7
95.6
0.83
400
11.2
2.8
1■Q1222-3BC73-3■■■
750 rpm, 6-pole
155
208
315
Y
38.0
1975
93.3
94.5
94.8
0.80
180
7.3
2.5
1■Q1222-3AC13-4■■■
205
275
315
Δ
37.9
2611
93.9
95.0
95.1
0.80
235
7.8
2.6
1■Q1222-3AC33-4■■■
225
302
315
Δ
38.0
2866
93.9
95.0
95.3
0.83
250
7.5
2.5
1■Q1222-3AC53-4■■■
245
329
315
Δ
38.0
3121
93.9
95.0
95.4
0.84
270
7.2
2.4
1■Q1222-3AC73-4■■■
295
396
355
Δ
37.9
3757
94.1
95.2
95.2
0.85
320
8.9
2.6
1■Q1222-3BC53-4■■■
320
429
355
Δ
37.9
4076
94.2
95.2
95.3
0.86
340
8.8
2.4
1■Q1222-3BC73-4■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC73-4■■■
Prated
5/14
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency – low noise
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1212-3AB13-1...
1.Q1212-3AB33-1...
1.Q1212-3AB53-1...
1.Q1212-3AB73-1...
1.Q1212-3BB53-1...
1.Q1212-3BB73-1...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG34-7AA3
250
320
320
400
452
452
1.Q1212-3AB13-2...
1.Q1212-3AB33-2...
1.Q1212-3AB53-2...
1.Q1212-3AB73-2...
1.Q1212-3BB53-2...
1.Q1212-3BB73-2...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG32-2AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
208
320
320
400
400
452
1.Q1212-3AC13-3...
1.Q1212-3AC33-3...
1.Q1212-3AC53-3...
1.Q1212-3AC73-3...
1.Q1212-3BC53-3...
1.Q1212-3BC73-3...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
6SL3710-7LG32-2AA3
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
208
250
320
320
400
400
1.Q1212-3AC13-4...
1.Q1212-3AC33-4...
1.Q1212-3AC53-4...
1.Q1212-3AC73-4...
1.Q1212-3BC53-4...
1.Q1212-3BC73-4...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
6SL3710-7LG31-8AA3
6SL3710-7LG32-2AA3
6SL3710-7LG32-6AA3
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
170
208
250
250
320
320
1.Q1222-3AB13-1...
1.Q1222-3AB33-1...
1.Q1222-3AB53-1...
1.Q1222-3AB73-1...
1.Q1222-3BB53-1...
1.Q1222-3BB73-1...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GH32-6AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH34-7AA3
250
320
400
400
452
452
1.Q1222-3AB13-2...
1.Q1222-3AB33-2...
1.Q1222-3AB53-2...
1.Q1222-3AB73-2...
1.Q1222-3BB53-2...
1.Q1222-3BB73-2...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GH32-6AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH34-7AA3
250
320
400
400
452
452
1.Q1222-3AC13-3...
1.Q1222-3AC33-3...
1.Q1222-3AC53-3...
1.Q1222-3AC73-3...
1.Q1222-3BC53-3...
1.Q1222-3BC73-3...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-1GH32-6AA3
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
250
320
320
400
400
400
1.Q1222-3AC13-4...
1.Q1222-3AC33-4...
1.Q1222-3AC53-4...
1.Q1222-3AC73-4...
1.Q1222-3BC53-4...
1.Q1222-3BC73-4...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
6SL3710-1GH32-2AA3
6SL3710-1GH32-6AA3
6SL3710-1GH32-6AA3
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
208
250
250
320
320
400
Siemens D 81.8 · 04/2014
5
5/15
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency – increased output
■ Selection and ordering data
5
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V
3000 rpm, 4-pole
265
355
315
Δ
100.7 844
94.5
95.0
94.6
0.89
250
5.9
2.0
1■Q1312-3AB13-1■■■
1■Q1312-3AB33-1■■■
345
463
315
Δ
100.6 1098
95.1
95.6
95.2
0.90
315
6.9
2.3
395
530
315
Δ
100.5 1258
95.4
95.9
95.5
0.90
360
7.7
2.6
1■Q1312-3AB53-1■■■
440
590
315
Δ
100.6 1401
95.5
96.0
95.7
0.91
400
7.5
2.5
1■Q1312-3AB73-1■■■
1■Q1312-3BB53-1■■■
485
650
355
Δ
100.5 1544
95.6
96.2
95.9
0.89
450
6.4
2.3
510
684
355
Δ
100.6 1624
95.6
96.2
96.0
0.89
470
5.8
2.1
1■Q1312-3BB73-1■■■
1500 rpm, 4-pole
245
329
315
Δ
50.5
1560
94.4
95.3
95.5
0.87
235
7.2
2.7
1■Q1312-3AB13-2■■■
315
422
315
Δ
50.5
2006
94.8
95.7
95.9
0.87
300
8.2
3.0
1■Q1312-3AB33-2■■■
365
489
315
Δ
50.5
2324
95.1
95.9
96.1
0.88
340
8.5
3.0
1■Q1312-3AB53-2■■■
415
557
315
Δ
50.5
2642
95.2
96.1
96.2
0.89
385
8.9
2.8
1■Q1312-3AB73-2■■■
460
617
355
Δ
50.4
2929
95.5
96.4
96.5
0.88
430
7.7
3.0
1■Q1312-3BB53-2■■■
485
650
355
Δ
50.4
3088
95.6
96.5
96.5
0.88
450
8.2
3.1
1■Q1312-3BB73-2■■■
1000 rpm, 6-pole
215
288
315
Y
50.5
2055
94.1
95.1
95.3
0.81
220
7.3
2.3
1■Q1312-3AC13-3■■■
270
362
315
Y
50.5
2580
94.3
95.4
95.6
0.83
270
7.3
2.3
1■Q1312-3AC33-3■■■
310
416
315
Y
50.5
2962
94.4
95.5
95.7
0.84
305
7.1
2.2
1■Q1312-3AC53-3■■■
1■Q1312-3AC73-3■■■
350
469
315
Δ
50.5
3344
94.6
95.6
95.8
0.84
345
7.2
2.2
370
496
355
Δ
50.3
3535
94.9
95.7
95.7
0.85
360
9.3
2.8
1■Q1312-3BC53-3■■■
410
550
355
Δ
50.3
3916
95.1
95.9
95.7
0.85
400
10.1
2.5
1■Q1312-3BC73-3■■■
750 rpm, 6-pole
160
215
315
Y
38.0
2039
93.2
94.4
94.6
0.79
170
7.4
2.5
1■Q1312-3AC13-4■■■
220
295
315
Y
38.0
2803
93.3
94.6
95.0
0.82
225
6.9
2.3
1■Q1312-3AC33-4■■■
245
329
315
Δ
38.0
3122
93.3
94.6
95.1
0.84
245
6.7
2.2
1■Q1312-3AC53-4■■■
275
369
315
Δ
38.0
3504
93.5
94.8
95.2
0.85
270
6.6
2.1
1■Q1312-3AC73-4■■■
315
422
355
Y
37.9
4013
93.9
95.0
95.2
0.86
305
8.3
2.5
1■Q1312-3BC53-4■■■
350
469
355
Δ
37.9
4458
94.1
95.2
95.3
0.86
340
8.5
2.2
1■Q1312-3BC73-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V
3000 rpm, 4-pole
265
355
315
Δ
100.6 844
94.6
95.1
94.6
0.89
275
6.3
2.1
1■Q1322-3AB13-1■■■
1■Q1322-3AB33-1■■■
330
443
315
Δ
100.6 1051
95.1
95.6
95.2
0.90
335
6.9
2.3
380
510
315
Δ
100.5 1210
95.4
95.8
95.4
0.90
385
7.9
2.6
1■Q1322-3AB53-1■■■
435
583
315
Δ
100.6 1385
95.5
96.0
95.7
0.91
435
7.7
2.5
1■Q1322-3AB73-1■■■
465
624
355
Δ
100.5 1481
95.6
96.2
95.8
0.89
475
6.8
2.4
1■Q1322-3BB53-1■■■
485
650
355
Δ
100.6 1544
95.6
96.2
96.0
0.89
495
6.1
2.2
1■Q1322-3BB73-1■■■
1500 rpm, 4-pole
250
335
315
Δ
50.5
1592
94.4
95.4
95.6
0.87
265
7.1
2.6
1■Q1322-3AB13-2■■■
310
416
315
Δ
50.5
1974
94.8
95.7
95.9
0.88
320
7.8
2.8
1■Q1322-3AB33-2■■■
350
469
315
Δ
50.5
2228
94.9
95.9
96.0
0.89
360
8.2
2.9
1■Q1322-3AB53-2■■■
415
557
315
Δ
50.5
2642
95.2
96.1
96.2
0.89
425
8.6
2.8
1■Q1322-3AB73-2■■■
455
610
355
Δ
50.4
2897
95.7
96.5
96.4
0.86
480
8.8
3.4
1■Q1322-3BB53-2■■■
480
644
355
Δ
50.4
3056
95.6
96.5
96.5
0.88
495
8.0
3.1
1■Q1322-3BB73-2■■■
1000 rpm, 6-pole
215
288
315
Y
50.5
2055
94.1
95.1
95.3
0.81
245
7.2
2.3
1■Q1322-3AC13-3■■■
270
362
315
Δ
50.5
2580
94.4
95.4
95.6
0.83
300
7.4
2.3
1■Q1322-3AC33-3■■■
315
422
315
Δ
50.5
3010
94.5
95.5
95.8
0.84
345
7.1
2.2
1■Q1322-3AC53-3■■■
1■Q1322-3AC73-3■■■
345
463
315
Δ
50.5
3296
94.7
95.7
95.8
0.83
380
7.6
2.2
370
496
355
Δ
50.4
3535
94.9
95.7
95.7
0.86
395
9.1
2.8
1■Q1322-3BC53-3■■■
405
543
355
Δ
50.3
3868
95.1
95.9
95.7
0.84
440
10.1
2.6
1■Q1322-3BC73-3■■■
750 rpm, 6-pole
170
228
315
Y
38.0
2166
92.8
94.1
94.6
0.81
196
6.7
2.3
1■Q1322-3AC13-4■■■
220
295
315
Δ
38.0
2803
93.5
94.7
95.0
0.81
250
7.3
2.5
1■Q1322-3AC33-4■■■
250
335
315
Δ
38.0
3185
93.4
94.7
95.1
0.84
275
6.8
2.2
1■Q1322-3AC53-4■■■
270
362
315
Δ
38.0
3441
93.3
94.7
95.1
0.85
295
6.6
2.1
1■Q1322-3AC73-4■■■
315
422
355
Δ
37.9
4012
94.0
95.1
95.2
0.86
335
8.5
2.5
1■Q1322-3BC53-4■■■
340
456
355
Δ
37.9
4331
94.0
95.1
95.3
0.86
365
8.2
2.3
1■Q1322-3BC73-4■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC73-4■■■
Prated
5/16
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency – increased output
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1312-3AB13-1...
1.Q1312-3AB33-1...
1.Q1312-3AB53-1...
1.Q1312-3AB73-1...
1.Q1312-3BB53-1...
1.Q1312-3BB73-1...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
250
320
400
400
452
560
1.Q1312-3AB13-2...
1.Q1312-3AB33-2...
1.Q1312-3AB53-2...
1.Q1312-3AB73-2...
1.Q1312-3BB53-2...
1.Q1312-3BB73-2...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG34-7AA3
250
320
400
400
452
452
1.Q1312-3AC13-3...
1.Q1312-3AC33-3...
1.Q1312-3AC53-3...
1.Q1312-3AC73-3...
1.Q1312-3BC53-3...
1.Q1312-3BC73-3...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
250
320
320
400
400
400
1.Q1312-3AC13-4...
1.Q1312-3AC33-4...
1.Q1312-3AC53-4...
1.Q1312-3AC73-4...
1.Q1312-3BC53-4...
1.Q1312-3BC73-4...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
6SL3710-7LG31-8AA3
6SL3710-7LG32-6AA3
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
170
250
250
320
320
400
1.Q1322-3AB13-1...
1.Q1322-3AB33-1...
1.Q1322-3AB53-1...
1.Q1322-3AB73-1...
1.Q1322-3BB53-1...
1.Q1322-3BB73-1...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH35-8AA3
320
400
400
452
560
560
1.Q1322-3AB13-2...
1.Q1322-3AB33-2...
1.Q1322-3AB53-2...
1.Q1322-3AB73-2...
1.Q1322-3BB53-2...
1.Q1322-3BB73-2...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH35-8AA3
320
320
400
452
560
560
1.Q1322-3AC13-3...
1.Q1322-3AC33-3...
1.Q1322-3AC53-3...
1.Q1322-3AC73-3...
1.Q1322-3BC53-3...
1.Q1322-3BC73-3...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GH32-6AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
250
320
400
400
400
452
1.Q1322-3AC13-4...
1.Q1322-3AC33-4...
1.Q1322-3AC53-4...
1.Q1322-3AC73-4...
1.Q1322-3BC53-4...
1.Q1322-3BC73-4...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
6SL3710-1GH32-2AA3
6SL3710-1GH32-6AA3
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
208
250
320
320
400
400
Siemens D 81.8 · 04/2014
5
5/17
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V
1500 rpm, 4-pole
5
185
248
315
Δ
50.4
1178
95.2
95.9
95.8
0.83
184
9.3
3.6
1■Q1213-3AB13-2■■■
300
402
315
Δ
50.4
1910
95.1
96.0
96.1
0.87
285
8.6
3.1
1■Q1213-3AB33-2■■■
340
456
315
Δ
50.4
2165
95.3
96.2
96.3
0.87
320
8.9
3.2
1■Q1213-3AB53-2■■■
395
530
315
Δ
50.4
2515
95.4
96.3
96.4
0.88
370
9.2
2.9
1■Q1213-3AB73-2■■■
425
570
355
Δ
50.4
2706
95.8
96.7
96.8
0.87
400
8.3
3.2
1■Q1213-3BB53-2■■■
465
624
355
Δ
50.4
2961
95.8
96.8
96.9
0.87
435
8.5
3.3
1■Q1213-3BB73-2■■■
1000 rpm, 6-pole
175
235
315
Y
50.4
1672
94.9
95.7
95.7
0.79
184
8.8
2.9
1■Q1213-3AC13-3■■■
240
322
315
Y
50.4
2293
94.8
95.8
95.9
0.82
240
8.2
2.6
1■Q1213-3AC33-3■■■
285
382
315
Y
50.5
2723
94.8
95.8
96.0
0.83
285
7.6
2.4
1■Q1213-3AC53-3■■■
325
436
315
Δ
50.5
3105
94.9
95.9
96.1
0.84
320
7.7
2.4
1■Q1213-3AC73-3■■■
365
489
355
Δ
50.3
3487
95.3
96.2
96.2
0.84
355
9.4
2.8
1■Q1213-3BC53-3■■■
405
543
355
Δ
50.3
3868
95.5
96.3
96.3
0.83
400
10.1
2.6
1■Q1213-3BC73-3■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V
1500 rpm, 4-pole
185
248
315
Δ
50.4
1178
95.2
95.9
95.8
0.84
200
9.3
3.5
1■Q1223-3AB13-2■■■
285
382
315
Δ
50.5
1815
95.1
96.0
96.1
0.88
295
8.4
3.0
1■Q1223-3AB33-2■■■
330
443
315
Δ
50.5
2101
95.2
96.1
96.2
0.88
340
8.7
3.1
1■Q1223-3AB53-2■■■
390
523
315
Δ
50.4
2483
95.4
96.3
96.4
0.89
400
9.0
3.0
1■Q1223-3AB73-2■■■
420
563
355
Δ
50.3
2676
96.0
96.8
96.8
0.84
450
9.4
3.7
1■Q1223-3BB53-2■■■
450
603
355
Δ
50.4
2865
95.9
96.8
96.9
0.87
465
8.5
3.3
1■Q1223-3BB73-2■■■
1000 rpm, 6-pole
175
235
315
Y
50.4
1672
94.9
95.7
95.7
0.79
200
8.8
2.8
1■Q1223-3AC13-3■■■
240
322
315
Δ
50.4
2293
94.8
95.8
95.9
0.81
270
8.2
2.6
1■Q1223-3AC33-3■■■
290
389
315
Δ
50.5
2771
94.8
95.9
96.1
0.84
315
7.7
2.4
1■Q1223-3AC53-3■■■
320
429
315
Δ
50.4
3057
95.0
95.9
96.1
0.83
350
8.2
2.4
1■Q1223-3AC73-3■■■
360
483
355
Δ
50.3
3439
95.3
96.2
96.2
0.85
385
9.3
2.9
1■Q1223-3BC53-3■■■
395
530
355
Δ
50.3
3772
95.5
96.3
96.3
0.83
430
10.4
2.6
1■Q1223-3BC73-3■■■
For versions, see Article No. supplements and special versions
5/18
Siemens D 81.8 · 04/2014
1■M1223-3AC73-3■■■
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1213-3AB13-2...
1310
1360
3.5
79
94.5
3000
1XB7 730
6SL3710-7LG32-2AA3
208
1.Q1213-3AB33-2...
1490
1540
4.4
79
94.5
3000
1XB7 730
6SL3710-7LG33-3AA3
320
1.Q1213-3AB53-2...
1670
1720
5
79
94.5
3000
1XB7 730
6SL3710-7LG33-3AA3
320
1.Q1213-3AB73-2...
1830
1880
5.8
79
94.5
3000
1XB7 731
6SL3710-7LG34-1AA3
400
1.Q1213-3BB53-2...
2300
2350
8.3
79
95
2600
1XB7 731
6SL3710-7LG34-1AA3
400
1.Q1213-3BB73-2...
2420
2480
8.9
79
95
2600
1XB7 731
6SL3710-7LG34-7AA3
452
1.Q1213-3AC13-3...
1340
1390
5.9
79
94.5
2600
1XB7 730
6SL3710-7LG32-2AA3
208
1.Q1213-3AC33-3...
1520
1570
7.2
79
94.5
2600
1XB7 730
6SL3710-7LG32-6AA3
250
1.Q1213-3AC53-3...
1700
1750
8.3
79
94.5
2600
1XB7 730
6SL3710-7LG33-3AA3
320
1.Q1213-3AC73-3...
1810
1860
9.1
79
94.5
2600
1XB7 730
6SL3710-7LG33-3AA3
320
1.Q1213-3BC53-3...
2290
2350
14.5
79
95
2500
1XB7 731
6SL3710-7LG34-1AA3
400
1.Q1213-3BC73-3...
2440
2490
16
79
95
2500
1XB7 731
6SL3710-7LG34-1AA3
400
1.Q1223-3AB13-2...
1310
1360
3.5
79
94.5
3000
1XB7 730
6SL3710-1GH32-2AA3
208
1.Q1223-3AB33-2...
1490
1540
4.4
79
94.5
3000
1XB7 730
6SL3710-1GH33-3AA3
320
1.Q1223-3AB53-2...
1670
1720
5
79
94.5
3000
1XB7 730
6SL3710-1GH34-1AA3
400
1.Q1223-3AB73-2...
1830
1880
5.8
79
94.5
3000
1XB7 731
6SL3710-1GH34-1AA3
400
1.Q1223-3BB53-2...
2300
2350
8.3
79
95
2600
1XB7 731
6SL3710-1GH34-7AA3
452
1.Q1223-3BB73-2...
2420
2480
8.9
79
95
2600
1XB7 731
6SL3710-1GH35-8AA3
560
1.Q1223-3AC13-3...
1340
1390
5.9
79
94.5
2600
1XB7 730
6SL3710-1GH32-2AA3
208
1.Q1223-3AC33-3...
1520
1570
7.2
79
94.5
2600
1XB7 730
6SL3710-1GH33-3AA3
320
1.Q1223-3AC53-3...
1700
1750
8.3
79
94.5
2600
1XB7 730
6SL3710-1GH33-3AA3
320
1.Q1223-3AC73-3...
1810
1860
9.1
79
94.5
2600
1XB7 730
6SL3710-1GH34-1AA3
400
1.Q1223-3BC53-3...
2290
2350
14.5
79
95
2500
1XB7 731
6SL3710-1GH34-1AA3
400
1.Q1223-3BC73-3...
2440
2490
16
79
95
2500
1XB7 731
6SL3710-1GH34-7AA3
452
Siemens D 81.8 · 04/2014
5
5/19
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency – low noise
■ Selection and ordering data
5
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V
3600 rpm, 4-pole
285
382
315
Δ
120.6 756
94.5
94.7
93.8
0.88
410
7.2
2.4
1■Q1212-3AB15-5■■■
345
463
315
Δ
120.5 915
95.0
95.2
94.3
0.89
490
8.6
2.9
1■Q1212-3AB35-5■■■
375
503
315
Δ
120.6 995
95.1
95.4
94.7
0.90
530
7.1
2.4
1■Q1212-3AB55-5■■■
430
577
315
Δ
120.6 1141
95.4
95.7
95.0
0.91
590
7.8
2.5
1■Q1212-3AB75-5■■■
3000 rpm, 4-pole
450
603
355
Δ
100.6 1433
95.6
96.2
95.9
0.89
630
6.1
2.2
1■Q1212-3BB55-1■■■
1■Q1212-3BB75-1■■■
495
664
355
Δ
100.5 1576
95.8
96.4
96.0
0.89
690
7.2
2.6
1800 rpm, 4-pole
285
382
315
Δ
60.5
1512
95.2
96.0
95.9
0.86
415
7.8
2.8
1■Q1212-3AB15-6■■■
1■Q1212-3AB35-6■■■
350
469
315
Δ
60.5
1857
95.5
96.1
96.2
0.88
495
8.0
2.8
1■Q1212-3AB55-6■■■
390
523
315
Δ
60.5
2069
95.6
96.4
96.4
0.89
550
8.1
2.8
480
644
315
Δ
60.4
2549
96.0
96.7
96.6
0.88
680
9.9
2.9
1■Q1212-3AB75-6■■■
485
650
355
Δ
60.4
2575
96.1
96.8
96.6
0.86
700
9.3
3.6
1■Q1212-3BB55-6■■■
1■Q1212-3BB75-6■■■
510
684
355
Δ
60.4
2706
96.0
96.8
96.7
0.88
720
8.4
3.2
1200 rpm, 6-pole
240
322
315
Δ
60.5
1911
95.0
95.7
95.9
0.82
365
7.5
2.3
1■Q1212-3AC15-7■■■
295
396
315
Δ
60.5
2349
95.2
95.7
96.1
0.84
445
7.5
2.3
1■Q1212-3AC35-7■■■
355
476
315
Δ
60.5
2826
95.5
95.7
96.3
0.84
530
8.1
2.5
1■Q1212-3AC55-7■■■
1■Q1212-3AC75-7■■■
380
510
315
Δ
60.5
3026
95.5
96.3
96.3
0.84
570
7.8
2.4
400
536
355
Δ
60.3
3184
95.6
96.3
95.9
0.84
590
11.0
3.1
1■Q1212-3BC55-7■■■
1■Q1212-3BC75-7■■■
445
597
355
Δ
60.3
3541
95.7
96.3
96.0
0.85
650
10.6
2.8
900 rpm, 6-pole
205
275
315
Δ
45.5
2177
94.3
95.4
95.5
0.80
325
7.2
2.4
1■Q1212-3AC15-8■■■
1■Q1212-3AC35-8■■■
250
335
315
Δ
45.4
2653
94.8
95.6
95.7
0.79
400
8.0
2.7
280
375
315
Δ
45.5
2972
94.6
95.6
95.8
0.84
420
7.2
2.3
1■Q1212-3AC55-8■■■
1■Q1212-3AC75-8■■■
310
416
315
Δ
45.5
3291
94.7
95.7
95.9
0.84
465
7.4
2.2
355
476
355
Δ
45.4
3768
94.7
95.7
95.7
0.86
520
8.2
2.6
1■Q1212-3BC55-8■■■
395
530
355
Δ
45.4
4193
94.9
95.8
95.8
0.86
580
8.6
2.4
1■Q1212-3BC75-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V
3600 rpm, 4-pole
285
382
315
Δ
120.5 756
94.6
94.7
93.7
0.88
450
7.6
2.6
1■Q1222-3AB15-5■■■
345
463
315
Δ
120.6 915
95.0
95.2
94.4
0.90
530
7.2
2.4
1■Q1222-3AB35-5■■■
380
510
315
Δ
120.5 1008
95.2
95.4
94.7
0.90
580
8.2
2.7
1■Q1222-3AB55-5■■■
1■Q1222-3AB75-5■■■
425
570
315
Δ
120.4 1127
95.4
95.6
94.9
0.90
650
9.5
3.1
3000 rpm, 4-pole
445
597
355
Δ
100.5 1417
95.7
96.2
95.8
0.89
680
7.2
2.6
1■Q1222-3BB55-1■■■
470
630
355
Δ
100.5 1496
95.7
96.3
96.0
0.89
720
6.3
2.3
1■Q1222-3BB75-1■■■
1800 rpm, 4-pole
280
375
315
Δ
60.5
1486
95.3
96.0
95.9
0.86
445
7.9
2.9
1■Q1222-3AB15-6■■■
350
469
315
Δ
60.5
1857
95.5
96.1
96.2
0.88
540
8.3
2.9
1■Q1222-3AB35-6■■■
400
536
315
Δ
60.5
2122
95.7
96.4
96.4
0.89
610
8.5
3.0
1■Q1222-3AB55-6■■■
460
617
315
Δ
60.5
2441
95.8
96.6
96.6
0.90
690
8.8
3.0
1■Q1222-3AB75-6■■■
470
630
355
Δ
60.4
2494
95.9
96.7
96.7
0.88
720
8.2
3.1
1■Q1222-3BB55-6■■■
520
697
355
Δ
60.4
2761
96.1
96.8
96.7
0.87
810
9.4
3.6
1■Q1222-3BB75-6■■■
1200 rpm, 6-pole
250
335
315
Δ
60.5
1991
95.2
95.7
96.0
0.80
425
8.1
2.5
1■Q1222-3AC15-7■■■
305
409
315
Δ
60.5
2428
95.3
95.7
96.1
0.83
500
7.8
2.4
1■Q1222-3AC35-7■■■
345
463
315
Δ
60.5
2747
95.4
95.7
96.2
0.84
560
7.9
2.4
1■Q1222-3AC55-7■■■
385
516
315
Δ
60.5
3065
95.5
96.3
96.4
0.85
620
7.6
2.3
1■Q1222-3AC75-7■■■
400
536
355
Δ
60.3
3184
95.6
96.3
95.9
0.84
650
10.7
3.1
1■Q1222-3BC55-7■■■
1■Q1222-3BC75-7■■■
440
590
355
Δ
60.3
3502
95.7
96.3
96.0
0.85
710
10.6
2.8
900 rpm, 6-pole
200
268
315
Δ
45.5
2123
94.4
95.3
95.4
0.78
355
7.6
2.6
1■Q1222-3AC15-8■■■
250
335
315
Δ
45.5
2654
94.6
95.5
95.7
0.81
425
7.5
2.5
1■Q1222-3AC35-8■■■
280
375
315
Δ
45.5
2973
94.6
95.6
95.8
0.83
465
7.4
2.4
1■Q1222-3AC55-8■■■
310
416
315
Δ
45.5
3291
94.6
95.7
95.9
0.85
500
7.0
2.2
1■Q1222-3AC75-8■■■
355
476
355
Δ
45.4
3768
94.8
95.7
95.7
0.86
570
8.7
2.6
1■Q1222-3BC55-8■■■
395
530
355
Δ
45.3
4193
95.0
95.9
95.8
0.85
640
9.4
2.4
1■Q1222-3BC75-8■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC75-8■■■
Prated
5/20
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency – low noise
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1212-3AB15-5...
1.Q1212-3AB35-5...
1.Q1212-3AB55-5...
1.Q1212-3AB75-5...
1310
1490
1670
1830
1360
1540
1720
1880
3.5
4.4
5
5.8
79
79
79
79
94.5
94.5
94.5
94.5
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
477
590
590
590
1.Q1212-3BB55-1...
1.Q1212-3BB75-1...
2300
2420
2350
2480
8.3
8.9
79
79
95
95
3300
3300
1XB7 740
1XB7 740
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
725
725
1.Q1212-3AB15-6...
1.Q1212-3AB35-6...
1.Q1212-3AB55-6...
1.Q1212-3AB75-6...
1.Q1212-3BB55-6...
1.Q1212-3BB75-6...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
477
590
590
725
725
725
1.Q1212-3AC15-7...
1.Q1212-3AC35-7...
1.Q1212-3AC55-7...
1.Q1212-3AC75-7...
1.Q1212-3BC55-7...
1.Q1212-3BC75-7...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-7LE33-8AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
370
477
590
590
590
725
1.Q1212-3AC15-8...
1.Q1212-3AC35-8...
1.Q1212-3AC55-8...
1.Q1212-3AC75-8...
1.Q1212-3BC55-8...
1.Q1212-3BC75-8...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LE33-8AA3
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
370
477
477
477
590
590
1.Q1222-3AB15-5...
1.Q1222-3AB35-5...
1.Q1222-3AB55-5...
1.Q1222-3AB75-5...
1310
1490
1670
1830
1360
1540
1720
1880
3.5
4.4
5
5.8
79
79
79
79
94.5
94.5
94.5
94.5
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
477
590
590
725
1.Q1222-3BB55-1...
1.Q1222-3BB75-1...
2300
2420
2350
2480
8.3
8.9
79
79
95
95
3300
3300
1XB7 740
1XB7 740
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
725
725
1.Q1222-3AB15-6...
1.Q1222-3AB35-6...
1.Q1222-3AB55-6...
1.Q1222-3AB75-6...
1.Q1222-3BB55-6...
1.Q1222-3BB75-6...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
477
590
725
725
725
820
1.Q1222-3AC15-7...
1.Q1222-3AC35-7...
1.Q1222-3AC55-7...
1.Q1222-3AC75-7...
1.Q1222-3BC55-7...
1.Q1222-3BC75-7...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
477
590
590
725
725
725
1.Q1222-3AC15-8...
1.Q1222-3AC35-8...
1.Q1222-3AC55-8...
1.Q1222-3AC75-8...
1.Q1222-3BC55-8...
1.Q1222-3BC75-8...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
370
477
477
590
590
725
Siemens D 81.8 · 04/2014
5
5/21
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency – increased output
■ Selection and ordering data
5
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V
3600 rpm, 4-pole
310
416
315
Δ
120.6 823
94.6
94.8
94.0
0.88
445
6.6
2.2
1■Q1312-3AB15-5■■■
385
516
315
Δ
120.5 1021
95.1
95.3
94.6
0.89
550
7.7
2.6
1■Q1312-3AB35-5■■■
410
550
315
Δ
120.6 1088
95.1
95.5
94.9
0.90
570
6.6
2.2
1■Q1312-3AB55-5■■■
470
630
315
Δ
120.6 1247
95.4
95.8
95.2
0.91
650
7.1
2.3
1■Q1312-3AB75-5■■■
3000 rpm, 4-pole
485
650
355
Δ
100.6 1544
95.6
96.3
96.0
0.89
680
5.7
2.0
1■Q1312-3BB55-1■■■
1■Q1312-3BB75-1■■■
540
724
355
Δ
100.5 1719
95.8
96.4
96.1
0.89
760
6.6
2.4
1800 rpm, 4-pole
300
402
315
Δ
60.5
1592
95.1
95.9
95.9
0.86
440
7.3
2.7
1■Q1312-3AB15-6■■■
1■Q1312-3AB35-6■■■
370
496
315
Δ
60.5
1963
95.3
96.1
96.2
0.89
520
7.6
2.7
1■Q1312-3AB55-6■■■
415
557
315
Δ
60.5
2202
95.4
96.3
96.3
0.90
580
7.7
2.7
510
684
315
Δ
60.4
2706
95.9
96.6
96.6
0.88
720
9.4
2.7
1■Q1312-3AB75-6■■■
555
744
355
Δ
60.4
2945
96.0
96.7
96.7
0.87
790
8.2
3.1
1■Q1312-3BB55-6■■■
1■Q1312-3BB75-6■■■
580
778
355
Δ
60.5
3078
95.9
96.7
96.8
0.89
810
7.5
2.8
1200 rpm, 6-pole
265
355
315
Δ
60.6
2111
94.7
95.6
95.8
0.82
405
6.7
2.0
1■Q1312-3AC15-7■■■
315
422
315
Δ
60.5
2509
95.0
95.7
96.0
0.84
470
7.1
2.1
1■Q1312-3AC35-7■■■
390
523
315
Δ
60.5
3105
95.2
96.1
96.2
0.84
580
7.4
2.2
1■Q1312-3AC55-7■■■
1■Q1312-3AC75-7■■■
420
563
315
Δ
60.5
3345
95.2
96.1
96.2
0.84
630
7.0
2.2
440
590
355
Δ
60.3
3502
95.6
96.3
96.0
0.85
650
9.9
2.8
1■Q1312-3BC55-7■■■
1■Q1312-3BC75-7■■■
485
650
355
Δ
60.3
3861
95.6
96.3
96.1
0.86
700
9.9
2.6
900 rpm, 6-pole
225
302
315
Δ
45.6
2389
93.9
95.1
95.4
0.81
350
6.7
2.2
1■Q1312-3AC15-8■■■
1■Q1312-3AC35-8■■■
280
375
315
Δ
45.5
2972
94.4
95.4
95.5
0.80
440
7.3
2.4
310
416
315
Δ
45.6
3289
94.2
95.3
95.6
0.84
465
6.5
2.1
1■Q1312-3AC55-8■■■
1■Q1312-3AC75-8■■■
340
456
315
Δ
45.5
3610
94.3
95.4
95.7
0.84
510
6.7
2.0
375
503
355
Δ
45.4
3981
94.6
95.6
95.7
0.87
540
7.9
2.5
1■Q1312-3BC55-8■■■
420
563
355
Δ
45.4
4458
94.7
95.7
95.8
0.87
610
8.1
2.2
1■Q1312-3BC75-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V
3600 rpm, 4-pole
315
422
315
Δ
120.6 836
94.6
94.8
94.0
0.88
495
6.9
2.3
1■Q1322-3AB15-5■■■
375
503
315
Δ
120.6 995
95.0
95.3
94.6
0.90
570
6.7
2.2
1■Q1322-3AB35-5■■■
420
563
315
Δ
120.6 1114
95.2
95.5
94.9
0.90
640
7.4
2.4
1■Q1322-3AB55-5■■■
1■Q1322-3AB75-5■■■
475
637
315
Δ
120.5 1260
95.5
95.8
95.1
0.90
720
8.6
2.8
3000 rpm, 4-pole
490
657
355
Δ
100.5 1560
95.7
96.3
96.0
0.89
750
6.5
2.3
1■Q1322-3BB55-1■■■
510
684
355
Δ
100.6 1624
95.7
96.4
96.1
0.89
780
5.8
2.1
1■Q1322-3BB75-1■■■
1800 rpm, 4-pole
300
402
315
Δ
60.5
1592
95.1
95.9
95.9
0.86
475
7.4
2.7
1■Q1322-3AB15-6■■■
375
503
315
Δ
60.5
1990
95.3
96.1
96.2
0.88
580
7.8
2.7
1■Q1322-3AB35-6■■■
425
570
315
Δ
60.5
2255
95.5
96.3
96.4
0.89
650
8.0
2.8
1■Q1322-3AB55-6■■■
490
657
315
Δ
60.5
2600
95.6
96.4
96.5
0.90
740
8.2
2.8
1■Q1322-3AB75-6■■■
530
711
355
Δ
60.5
2812
95.8
96.7
96.7
0.89
810
7.2
2.7
1■Q1322-3BB55-6■■■
595
798
355
Δ
60.4
3157
96.0
96.8
96.8
0.88
920
8.3
3.1
1■Q1322-3BB75-6■■■
1200 rpm, 6-pole
280
375
315
Δ
60.5
2230
94.9
95.7
95.9
0.81
475
7.2
2.2
1■Q1322-3AC15-7■■■
335
449
315
Δ
60.5
2668
95.0
95.7
96.1
0.83
550
7.1
2.2
1■Q1322-3AC35-7■■■
380
510
315
Δ
60.5
3026
95.1
96.1
96.2
0.84
620
7.2
2.2
1■Q1322-3AC55-7■■■
425
570
315
Δ
60.5
3384
95.2
96.1
96.3
0.85
680
7.0
2.1
1■Q1322-3AC75-7■■■
435
583
355
Δ
60.3
3462
95.6
96.2
96.0
0.85
700
9.9
2.9
1■Q1322-3BC55-7■■■
1■Q1322-3BC75-7■■■
480
644
355
Δ
60.3
3821
95.6
96.3
96.1
0.86
760
9.9
2.6
900 rpm, 6-pole
220
295
315
Δ
45.5
2336
93.9
95.0
95.3
0.79
385
7.0
2.3
1■Q1322-3AC15-8■■■
275
369
315
Δ
45.5
2919
94.2
95.3
95.5
0.82
460
6.9
2.2
1■Q1322-3AC35-8■■■
310
416
315
Δ
45.5
3292
94.2
95.3
95.6
0.84
510
6.7
2.1
1■Q1322-3AC55-8■■■
340
456
315
Δ
45.6
3608
94.2
95.4
95.7
0.85
550
6.4
2.0
1■Q1322-3AC75-8■■■
370
496
355
Δ
45.4
3927
94.7
95.7
95.7
0.86
590
8.4
2.5
1■Q1322-3BC55-8■■■
425
570
355
Δ
45.4
4511
94.9
95.8
95.8
0.86
680
8.9
2.2
1■Q1322-3BC75-8■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC75-8■■■
Prated
5/22
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency – increased output
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1312-3AB15-5...
1.Q1312-3AB35-5...
1.Q1312-3AB55-5...
1.Q1312-3AB75-5...
1310
1490
1670
1830
1360
1540
1720
1880
3.5
4.4
5
5.8
85
85
85
85
100.5
100.5
100.5
100.5
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
477
590
590
725
1.Q1312-3BB55-1...
1.Q1312-3BB75-1...
2300
2420
2350
2480
8.3
8.9
85
85
101
101
3300
3300
1XB7 740
1XB7 740
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
725
820
1.Q1312-3AB15-6...
1.Q1312-3AB35-6...
1.Q1312-3AB55-6...
1.Q1312-3AB75-6...
1.Q1312-3BB55-6...
1.Q1312-3BB75-6...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE38-4AA3
477
590
590
725
820
820
1.Q1312-3AC15-7...
1.Q1312-3AC35-7...
1.Q1312-3AC55-7...
1.Q1312-3AC75-7...
1.Q1312-3BC55-7...
1.Q1312-3BC75-7...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
477
477
590
725
725
725
1.Q1312-3AC15-8...
1.Q1312-3AC35-8...
1.Q1312-3AC55-8...
1.Q1312-3AC75-8...
1.Q1312-3BC55-8...
1.Q1312-3BC75-8...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-7LE33-8AA3
6SL3710-7LE35-0AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
370
477
477
590
590
725
1.Q1322-3AB15-5...
1.Q1322-3AB35-5...
1.Q1322-3AB55-5...
1.Q1322-3AB75-5...
1310
1490
1670
1830
1360
1540
1720
1880
3.5
4.4
5
5.8
85
85
85
85
100.5
100.5
100.5
100.5
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
590
590
725
725
1.Q1322-3BB55-1...
1.Q1322-3BB75-1...
2300
2420
2350
2480
8.3
8.9
85
85
101
101
3300
3300
1XB7 740
1XB7 740
6SL3710-1GE38-4AA3
6SL3710-1GE38-4AA3
820
820
1.Q1322-3AB15-6...
1.Q1322-3AB35-6...
1.Q1322-3AB55-6...
1.Q1322-3AB75-6...
1.Q1322-3BB55-6...
1.Q1322-3BB75-6...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
477
590
725
820
820
960
1.Q1322-3AC15-7...
1.Q1322-3AC35-7...
1.Q1322-3AC55-7...
1.Q1322-3AC75-7...
1.Q1322-3BC55-7...
1.Q1322-3BC75-7...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
477
590
725
725
725
820
1.Q1322-3AC15-8...
1.Q1322-3AC35-8...
1.Q1322-3AC55-8...
1.Q1322-3AC75-8...
1.Q1322-3BC55-8...
1.Q1322-3BC75-8...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
477
477
590
590
590
725
Siemens D 81.8 · 04/2014
5
5/23
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V
1800 rpm, 4-pole
5
250
335
315
Δ
60.4
1326
95.5
96.2
96.0
0.85
370
8.7
3.2
1■Q1213-3AB15-6■■■
350
469
315
Δ
60.5
1857
95.5
96.3
96.4
0.88
495
8.0
2.8
1■Q1213-3AB35-6■■■
390
523
315
Δ
60.5
2069
95.6
96.4
96.5
0.89
550
8.1
2.8
1■Q1213-3AB55-6■■■
480
644
315
Δ
60.4
2547
96.0
96.7
96.7
0.88
680
9.8
2.9
1■Q1213-3AB75-6■■■
515
691
355
Δ
60.4
2732
96.2
97.0
97.0
0.86
740
8.7
3.4
1■Q1213-3BB55-6■■■
540
724
355
Δ
60.4
2865
96.1
97.0
97.1
0.88
760
7.9
3.0
1■Q1213-3BB75-6■■■
1200 rpm, 6-pole
240
322
315
Δ
60.5
1911
95.0
96.0
96.1
0.82
365
7.4
2.3
1■Q1213-3AC15-7■■■
305
409
315
Δ
60.5
2429
95.2
96.1
96.3
0.83
460
7.2
2.2
1■Q1213-3AC35-7■■■
360
483
315
Δ
60.5
2866
95.5
96.4
96.4
0.83
540
7.9
2.4
1■Q1213-3AC55-7■■■
390
523
315
Δ
60.5
3105
95.4
96.4
96.4
0.84
580
7.6
2.3
1■Q1213-3AC75-7■■■
435
583
355
Δ
60.3
3462
95.9
96.7
96.6
0.84
640
10.1
2.9
1■Q1213-3BC55-7■■■
480
644
355
Δ
60.3
3821
96.0
96.7
96.6
0.85
700
9.9
2.6
1■Q1213-3BC75-7■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V
1800 rpm, 4-pole
245
329
315
Δ
60.4
1300
95.5
96.2
96.1
0.84
400
8.8
3.3
1■Q1223-3AB15-6■■■
350
469
315
Δ
60.5
1857
95.5
96.3
96.4
0.88
540
8.3
2.9
1■Q1223-3AB35-6■■■
400
536
315
Δ
60.5
2122
95.7
96.5
96.6
0.89
610
8.5
3.0
1■Q1223-3AB55-6■■■
460
617
315
Δ
60.5
2441
95.8
96.6
96.7
0.90
690
8.8
3.0
1■Q1223-3AB75-6■■■
490
657
355
Δ
60.4
2600
96.1
96.9
97.0
0.88
750
7.8
2.9
1■Q1223-3BB55-6■■■
555
744
355
Δ
60.4
2945
96.3
97.1
97.1
0.87
860
8.8
3.4
1■Q1223-3BB75-6■■■
1200 rpm, 6-pole
260
349
315
Δ
60.5
2070
95.2
96.1
96.1
0.80
445
7.7
2.4
1■Q1223-3AC15-7■■■
310
416
315
Δ
60.5
2468
95.3
96.2
96.3
0.83
510
7.6
2.3
1■Q1223-3AC35-7■■■
355
476
315
Δ
60.5
2826
95.4
96.3
96.4
0.84
580
7.6
2.3
1■Q1223-3AC55-7■■■
395
530
315
Δ
60.5
3145
95.5
96.4
96.5
0.85
630
7.5
2.3
1■Q1223-3AC75-7■■■
430
577
355
Δ
60.3
3422
95.9
96.7
96.6
0.84
690
10.0
2.9
1■Q1223-3BC55-7■■■
470
630
355
Δ
60.3
3741
96.0
96.7
96.6
0.85
750
10.0
2.6
1■Q1223-3BC75-7■■■
For versions, see Article No. supplements and special versions
5/24
Siemens D 81.8 · 04/2014
1■M1223-3AC75-7■■■
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1213-3AB15-6...
1310
1360
3.5
79
94.5
3000
1XB7 731
6SL3710-7LE33-8AA3
370
1.Q1213-3AB35-6...
1490
1540
4.4
79
94.5
3000
1XB7 731
6SL3710-7LE36-1AA3
590
1.Q1213-3AB55-6...
1670
1720
5
79
94.5
3000
1XB7 731
6SL3710-7LE36-1AA3
590
1.Q1213-3AB75-6...
1830
1880
5.8
79
94.5
3000
1XB7 740
6SL3710-7LE37-5AA3
725
1.Q1213-3BB55-6...
2300
2350
8.3
79
95
2600
1XB7 740
6SL3710-7LE38-4AA3
820
1.Q1213-3BB75-6...
2420
2480
8.9
79
95
2600
1XB7 740
6SL3710-7LE38-4AA3
820
1.Q1213-3AC15-7...
1340
1390
5.9
79
94.5
2600
1XB7 731
6SL3710-7LE33-8AA3
370
1.Q1213-3AC35-7...
1520
1570
7.2
79
94.5
2600
1XB7 731
6SL3710-7LE35-0AA3
477
1.Q1213-3AC55-7...
1700
1750
8.3
79
94.5
2600
1XB7 731
6SL3710-7LE36-1AA3
590
1.Q1213-3AC75-7...
1810
1860
9.1
79
94.5
2600
1XB7 731
6SL3710-7LE36-1AA3
590
1.Q1213-3BC55-7...
2290
2350
14.5
79
95
2500
1XB7 740
6SL3710-7LE37-5AA3
725
1.Q1213-3BC75-7...
2440
2490
16
79
95
2500
1XB7 740
6SL3710-7LE37-5AA3
725
1.Q1223-3AB15-6...
1310
1360
3.5
79
94.5
3000
1XB7 731
6SL3710-1GE35-0AA3
477
1.Q1223-3AB35-6...
1490
1540
4.4
79
94.5
3000
1XB7 731
6SL3710-1GE36-1AA3
590
1.Q1223-3AB55-6...
1670
1720
5
79
94.5
3000
1XB7 740
6SL3710-1GE37-5AA3
725
1.Q1223-3AB75-6...
1830
1880
5.8
79
94.5
3000
1XB7 740
6SL3710-1GE37-5AA3
725
1.Q1223-3BB55-6...
2300
2350
8.3
79
95
2600
1XB7 740
6SL3710-1GE38-4AA3
820
1.Q1223-3BB75-6...
2420
2480
8.9
79
95
2600
1XB7 740
6SL3710-1GE41-0AA3
960
1.Q1223-3AC15-7...
1340
1390
5.9
79
94.5
2600
1XB7 731
6SL3710-1GE35-0AA3
477
1.Q1223-3AC35-7...
1520
1570
7.2
79
94.5
2600
1XB7 731
6SL3710-1GE36-1AA3
590
1.Q1223-3AC55-7...
1700
1750
8.3
79
94.5
2600
1XB7 731
6SL3710-1GE36-1AA3
590
1.Q1223-3AC75-7...
1810
1860
9.1
79
94.5
2600
1XB7 740
6SL3710-1GE37-5AA3
725
1.Q1223-3BC55-7...
2290
2350
14.5
79
95
2500
1XB7 740
6SL3710-1GE37-5AA3
725
1.Q1223-3BC75-7...
2440
2490
16
79
95
2500
1XB7 740
6SL3710-1GE38-4AA3
820
Siemens D 81.8 · 04/2014
5
5/25
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency – low noise
■ Selection and ordering data
5
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V
3600 rpm, 4-pole
270
362
315
Δ
120.6 717
94.3
94.5
93.6
0.88
305
6.9
2.3
1■Q1212-3AB16-5■■■
1■Q1212-3AB36-5■■■
335
449
315
Δ
120.5 889
94.9
95.0
94.2
0.89
375
8.6
2.9
370
496
315
Δ
120.5 982
95.1
95.3
94.5
0.89
415
9.0
3.0
1■Q1212-3AB56-5■■■
425
570
315
Δ
120.5 1127
95.4
95.6
94.8
0.90
470
9.3
3.0
1■Q1212-3AB76-5■■■
1■Q1212-3BB56-1■■■
435
583
355
Δ
100.6 1385
95.5
96.1
95.8
0.89
480
6.2
2.2
475
637
355
Δ
100.5 1512
95.7
96.3
95.9
0.89
520
6.8
2.4
1■Q1212-3BB76-1■■■
1800 rpm, 4-pole
255
342
315
Δ
60.5
1353
95.1
95.8
95.8
0.87
290
7.9
2.8
1■Q1212-3AB16-6■■■
330
443
315
Δ
60.4
1751
95.6
96.1
96.1
0.86
380
9.4
3.4
1■Q1212-3AB36-6■■■
370
496
315
Δ
60.4
1963
95.6
96.1
96.3
0.88
415
9.1
3.2
1■Q1212-3AB56-6■■■
440
590
315
Δ
60.4
2336
95.9
96.6
96.5
0.87
495
10.5
3.2
1■Q1212-3AB76-6■■■
450
603
355
Δ
60.3
2389
96.0
96.7
96.5
0.86
510
9.7
3.7
1■Q1212-3BB56-6■■■
480
644
355
Δ
60.3
2548
96.1
96.7
96.5
0.85
550
10.8
3.9
1■Q1212-3BB76-6■■■
1200 rpm, 6-pole
230
308
315
Δ
60.5
1831
95.0
95.7
95.8
0.81
280
8.2
2.5
1■Q1212-3AC16-7■■■
280
375
315
Δ
60.4
2229
95.2
95.7
96.0
0.82
335
8.5
2.6
1■Q1212-3AC36-7■■■
315
422
315
Δ
60.5
2508
95.3
95.7
96.1
0.84
370
8.1
2.5
1■Q1212-3AC56-7■■■
1■Q1212-3AC76-7■■■
350
469
315
Δ
60.4
2786
95.4
95.7
96.2
0.84
410
8.3
2.5
365
489
355
Δ
60.3
2905
95.6
95.7
95.6
0.81
445
12.3
3.4
1■Q1212-3BC56-7■■■
400
536
355
Δ
60.3
3184
95.6
96.2
95.8
0.83
475
11.9
3.1
1■Q1212-3BC76-7■■■
900 rpm, 6-pole
180
241
315
Y
45.4
1911
94.2
95.2
95.3
0.80
225
7.9
2.6
1■Q1212-3AC16-8■■■
235
315
315
Δ
45.4
2494
94.7
95.5
95.5
0.79
295
8.3
2.8
1■Q1212-3AC36-8■■■
265
355
315
Δ
45.4
2813
94.6
95.6
95.7
0.83
315
7.8
2.5
1■Q1212-3AC56-8■■■
285
382
315
Δ
45.4
3024
94.8
95.7
95.7
0.82
345
8.5
2.4
1■Q1212-3AC76-8■■■
330
443
355
Δ
45.3
3503
94.8
95.6
95.6
0.85
385
9.5
2.8
1■Q1212-3BC56-8■■■
365
489
355
Δ
45.3
3874
94.9
95.7
95.6
0.85
425
9.5
2.6
1■Q1212-3BC76-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V
3600 rpm, 4-pole
265
355
315
Δ
120.5 703
94.4
94.4
93.4
0.88
335
8.3
2.8
1■Q1222-3AB16-5■■■
1■Q1222-3AB36-5■■■
315
422
315
Δ
120.4 836
94.8
94.9
93.9
0.89
390
9.5
3.1
345
463
315
Δ
120.4 916
95.0
95.1
94.2
0.89
430
10.2
3.4
1■Q1222-3AB56-5■■■
400
536
315
Δ
120.5 1061
95.2
95.5
94.8
0.91
485
8.0
2.6
1■Q1222-3AB76-5■■■
1800 rpm, 4-pole
415
557
355
Δ
100.5 1321
95.6
96.1
95.7
0.89
510
6.7
2.4
1■Q1222-3BB56-1■■■
450
603
355
Δ
100.4 1433
95.7
96.2
95.8
0.89
550
7.6
2.7
1■Q1222-3BB76-1■■■
3000 rpm, 4-pole
250
335
315
Δ
60.5
1327
95.0
95.8
95.8
0.88
310
7.7
2.7
1■Q1222-3AB16-6■■■
325
436
315
Δ
60.4
1724
95.5
96.1
96.1
0.87
410
9.2
3.3
1■Q1222-3AB36-6■■■
365
489
315
Δ
60.4
1937
95.6
96.1
96.3
0.89
450
9.2
3.2
1■Q1222-3AB56-6■■■
435
583
315
Δ
60.4
2310
95.9
96.6
96.5
0.87
540
11.0
3.2
1■Q1222-3AB76-6■■■
470
630
355
Δ
60.4
2493
96.0
96.7
96.6
0.88
580
9.1
3.4
1■Q1222-3BB76-6■■■
1200 rpm, 6-pole
215
288
315
Δ
60.5
1712
94.8
95.7
95.8
0.82
290
7.6
2.4
1■Q1222-3AC16-7■■■
275
369
315
Δ
60.4
2189
95.2
95.7
96.0
0.82
365
8.5
2.6
1■Q1222-3AC36-7■■■
315
422
315
Δ
60.5
2508
95.3
95.7
96.1
0.84
410
8.1
2.5
1■Q1222-3AC56-7■■■
1■Q1222-3AC76-7■■■
345
463
315
Δ
60.4
2746
95.4
95.7
96.2
0.84
450
8.6
2.6
355
476
355
Δ
60.3
2826
95.5
95.7
95.7
0.83
465
11.9
3.5
1■Q1222-3BC56-7■■■
375
503
355
Δ
60.2
2986
95.6
95.7
95.5
0.80
510
13.4
3.3
1■Q1222-3BC76-7■■■
900 rpm, 6-pole
180
241
315
Δ
45.4
1910
94.3
95.2
95.2
0.77
260
8.3
2.8
1■Q1222-3AC16-8■■■
225
302
315
Δ
45.4
2388
94.6
95.4
95.4
0.77
320
8.7
3.0
1■Q1222-3AC36-8■■■
260
349
315
Δ
45.4
2759
94.6
95.6
95.6
0.82
350
8.2
2.7
1■Q1222-3AC56-8■■■
285
382
315
Δ
45.4
3025
94.8
95.7
95.7
0.82
380
8.4
2.4
1■Q1222-3AC76-8■■■
325
436
355
Δ
45.3
3450
94.8
95.6
95.6
0.85
420
9.4
2.9
1■Q1222-3BC56-8■■■
350
469
355
Δ
45.3
3715
94.9
95.7
95.6
0.85
450
10.0
2.7
1■Q1222-3BC76-8■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC76-8■■■
Prated
5/26
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency – low noise
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1212-3AB16-5...
1.Q1212-3AB36-5...
1.Q1212-3AB56-5...
1.Q1212-3AB76-5...
1.Q1212-3BB56-1...
1.Q1212-3BB76-1...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
320
400
452
560
560
560
1.Q1212-3AB16-6...
1.Q1212-3AB36-6...
1.Q1212-3AB56-6...
1.Q1212-3AB76-6...
1.Q1212-3BB56-6...
1.Q1212-3BB76-6...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
320
400
452
560
560
560
1.Q1212-3AC16-7...
1.Q1212-3AC36-7...
1.Q1212-3AC56-7...
1.Q1212-3AC76-7...
1.Q1212-3BC56-7...
1.Q1212-3BC76-7...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
320
400
400
452
452
560
1.Q1212-3AC16-8...
1.Q1212-3AC36-8...
1.Q1212-3AC56-8...
1.Q1212-3AC76-8...
1.Q1212-3BC56-8...
1.Q1212-3BC76-8...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
250
320
320
400
400
452
1.Q1222-3AB16-5...
1.Q1222-3AB36-5...
1.Q1222-3AB56-5...
1.Q1222-3AB76-5...
1310
1490
1670
1830
1360
1540
1720
1880
3.5
4.4
5
5.8
79
79
79
79
94.5
94.5
94.5
94.5
3600
3600
3600
3600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GF34-1AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
400
400
452
560
1.Q1222-3BB56-1...
1.Q1222-3BB76-1...
2300
2420
2350
2480
8.3
8.9
79
79
95
95
3300
3300
1XB7 731
1XB7 731
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
560
560
1.Q1222-3AB16-6...
1.Q1222-3AB36-6...
1.Q1222-3AB56-6...
1.Q1222-3AB76-6...
1.Q1222-3BB76-6...
1310
1490
1670
1830
2420
1360
1540
1720
1880
2480
3.5
4.4
5
5.8
8.9
79
79
79
79
79
94.5
94.5
94.5
94.5
95
3000
3000
3000
3000
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GF33-3AA3
6SL3710-1GF34-7AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
320
452
452
560
710
1.Q1222-3AC16-7...
1.Q1222-3AC36-7...
1.Q1222-3AC56-7...
1.Q1222-3AC76-7...
1.Q1222-3BC56-7...
1.Q1222-3BC76-7...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GF33-3AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
320
400
452
452
560
560
1.Q1222-3AC16-8...
1.Q1222-3AC36-8...
1.Q1222-3AC56-8...
1.Q1222-3AC76-8...
1.Q1222-3BC56-8...
1.Q1222-3BC76-8...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GF33-3AA3
6SL3710-1GF33-3AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF34-7AA3
320
320
400
400
452
452
Siemens D 81.8 · 04/2014
5
5/27
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency – increased output
■ Selection and ordering data
5
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V
3600 rpm, 4-pole
295
396
315
Δ
120.6 783
94.3
94.6
93.8
0.88
335
6.3
2.1
1■Q1312-3AB16-5■■■
375
503
315
Δ
120.5 995
95.0
95.2
94.5
0.89
420
7.7
2.6
1■Q1312-3AB36-5■■■
410
550
315
Δ
120.5 1088
95.2
95.4
94.7
0.90
450
8.3
2.7
1■Q1312-3AB56-5■■■
470
630
315
Δ
120.5 1247
95.4
95.7
95.1
0.90
520
8.4
2.7
1■Q1312-3AB76-5■■■
3000 rpm, 4-pole
470
630
355
Δ
100.6 1497
95.5
96.1
95.9
0.89
520
5.7
2.0
1■Q1312-3BB56-1■■■
1■Q1312-3BB76-1■■■
510
684
355
Δ
100.5 1624
95.7
96.3
96.0
0.89
560
6.3
2.3
1800 rpm, 4-pole
270
362
315
Δ
60.5
1433
94.9
95.7
95.7
0.87
305
7.5
2.7
1■Q1312-3AB16-6■■■
1■Q1312-3AB36-6■■■
355
476
315
Δ
60.5
1883
95.4
96.1
96.1
0.87
400
8.9
3.2
1■Q1312-3AB56-6■■■
395
530
315
Δ
60.5
2096
95.4
96.2
96.3
0.89
435
8.7
3.0
475
637
315
Δ
60.4
2520
95.8
96.5
96.5
0.88
530
9.8
2.9
1■Q1312-3AB76-6■■■
515
691
355
Δ
60.4
2732
95.9
96.6
96.6
0.87
580
8.5
3.3
1■Q1312-3BB56-6■■■
1■Q1312-3BB76-6■■■
560
751
355
Δ
60.4
2973
96.0
96.7
96.6
0.86
640
9.3
3.3
1200 rpm, 6-pole
255
342
315
Δ
60.5
2031
94.7
95.6
95.7
0.81
310
7.4
2.3
1■Q1312-3AC16-7■■■
310
416
315
Δ
60.5
2468
94.9
95.7
95.9
0.83
370
7.7
2.3
1■Q1312-3AC36-7■■■
350
469
315
Δ
60.5
2787
94.9
95.7
96.0
0.84
410
7.3
2.2
1■Q1312-3AC56-7■■■
1■Q1312-3AC76-7■■■
385
516
315
Δ
60.5
3065
95.1
96.0
96.1
0.84
450
7.5
2.3
405
543
355
Δ
60.3
3223
95.5
96.1
95.8
0.82
485
11.2
3.1
1■Q1312-3BC56-7■■■
1■Q1312-3BC76-7■■■
445
597
355
Δ
60.3
3542
95.5
96.2
95.9
0.84
520
10.8
2.8
900 rpm, 6-pole
200
268
315
Y
45.5
2124
93.7
94.8
95.1
0.81
245
7.3
2.3
1■Q1312-3AC16-8■■■
1■Q1312-3AC36-8■■■
255
342
315
Δ
45.5
2707
94.3
95.3
95.4
0.80
315
7.8
2.6
290
389
315
Δ
45.5
3079
94.2
95.3
95.6
0.84
345
7.2
2.3
1■Q1312-3AC56-8■■■
1■Q1312-3AC76-8■■■
320
429
315
Δ
45.5
3397
94.4
95.4
95.6
0.83
385
7.6
2.2
345
463
355
Δ
45.4
3662
94.7
95.6
95.6
0.85
400
9.1
2.7
1■Q1312-3BC56-8■■■
390
523
355
Δ
45.4
4140
94.7
95.6
95.6
0.86
450
9.0
2.4
1■Q1312-3BC76-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V
3600 rpm, 4-pole
295
396
315
Δ
120.5 783
94.5
94.6
93.8
0.88
370
7.5
2.5
1■Q1322-3AB16-5■■■
355
476
315
Δ
120.5 942
94.9
95.1
94.3
0.89
440
8.4
2.8
1■Q1322-3AB36-5■■■
390
523
315
Δ
120.5 1035
95.1
95.3
94.5
0.89
485
9.1
3.0
1■Q1322-3AB56-5■■■
1■Q1322-3AB76-5■■■
440
590
315
Δ
120.6 1167
95.2
95.6
95.0
0.91
530
7.3
2.4
3000 rpm, 4-pole
455
610
355
Δ
100.6 1449
95.5
96.2
95.8
0.89
560
6.1
2.2
1■Q1322-3BB56-1■■■
495
664
355
Δ
100.5 1576
95.7
96.3
95.9
0.89
610
6.9
2.5
1■Q1322-3BB76-1■■■
1800 rpm, 4-pole
270
362
315
Δ
60.6
1433
94.7
95.6
95.7
0.88
335
7.1
2.5
1■Q1322-3AB16-6■■■
345
463
315
Δ
60.5
1830
95.3
96.1
96.0
0.87
435
8.7
3.1
1■Q1322-3AB36-6■■■
390
523
315
Δ
60.5
2069
95.4
96.2
96.3
0.89
480
8.6
3.0
1■Q1322-3AB56-6■■■
470
630
315
Δ
60.4
2496
95.8
96.5
96.4
0.87
590
10.0
3.0
1■Q1322-3AB76-6■■■
505
677
355
Δ
60.4
2679
95.9
96.7
96.6
0.87
630
9.0
3.4
1■Q1322-3BB56-6■■■
535
717
355
Δ
60.4
2839
95.9
96.7
96.7
0.89
650
8.1
3.0
1■Q1322-3BB76-6■■■
1200 rpm, 6-pole
240
322
315
Δ
60.6
1912
94.4
95.5
95.7
0.83
320
6.9
2.1
1■Q1322-3AC16-7■■■
300
402
315
Δ
60.5
2389
95.0
95.7
95.9
0.83
395
7.9
2.4
1■Q1322-3AC36-7■■■
345
463
315
Δ
60.5
2747
95.0
95.7
96.0
0.84
450
7.4
2.2
1■Q1322-3AC56-7■■■
390
523
315
Δ
60.5
3105
95.1
96.0
96.1
0.84
510
7.6
2.3
1■Q1322-3AC76-7■■■
395
530
355
Δ
60.3
3144
95.5
96.1
95.8
0.84
510
10.8
3.1
1■Q1322-3BC56-7■■■
1■Q1322-3BC76-7■■■
420
563
355
Δ
60.3
3343
95.6
96.1
95.7
0.82
560
12.2
3.0
900 rpm, 6-pole
200
268
315
Δ
45.5
2123
93.9
94.9
95.1
0.78
285
7.6
2.6
1■Q1322-3AC16-8■■■
250
335
315
Δ
45.4
2654
94.3
95.2
95.3
0.79
350
7.9
2.7
1■Q1322-3AC36-8■■■
290
389
315
Δ
45.5
3079
94.2
95.3
95.5
0.83
385
7.4
2.4
1■Q1322-3AC56-8■■■
315
422
315
Δ
45.5
3344
94.4
95.4
95.6
0.83
420
7.6
2.2
1■Q1322-3AC76-8■■■
345
463
355
Δ
45.4
3662
94.6
95.6
95.6
0.86
440
9.0
2.7
1■Q1322-3BC56-8■■■
380
510
355
Δ
45.3
4033
94.8
95.7
95.6
0.86
485
9.3
2.5
1■Q1322-3BC76-8■■■
For versions, see Article No. supplements and special versions
1■M1222-3AC76-8■■■
Prated
5/28
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency – increased output
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1312-3AB16-5...
1.Q1312-3AB36-5...
1.Q1312-3AB56-5...
1.Q1312-3AB76-5...
1310
1490
1670
1830
1360
1540
1720
1880
3.5
4.4
5
5.8
85
85
85
85
100.5
100.5
100.5
100.5
3600
3600
3600
3600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
400
452
452
560
1.Q1312-3BB56-1...
1.Q1312-3BB76-1...
2300
2420
2350
2480
8.3
8.9
85
85
101
101
3300
3300
1XB7 731
1XB7 731
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
560
560
1.Q1312-3AB16-6...
1.Q1312-3AB36-6...
1.Q1312-3AB56-6...
1.Q1312-3AB76-6...
1.Q1312-3BB56-6...
1.Q1312-3BB76-6...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
320
400
452
560
710
710
1.Q1312-3AC16-7...
1.Q1312-3AC36-7...
1.Q1312-3AC56-7...
1.Q1312-3AC76-7...
1.Q1312-3BC56-7...
1.Q1312-3BC76-7...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
320
400
452
452
560
560
1.Q1312-3AC16-8...
1.Q1312-3AC36-8...
1.Q1312-3AC56-8...
1.Q1312-3AC76-8...
1.Q1312-3BC56-8...
1.Q1312-3BC76-8...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
250
320
400
400
400
452
1.Q1322-3AB16-5...
1.Q1322-3AB36-5...
1.Q1322-3AB56-5...
1.Q1322-3AB76-5...
1310
1490
1670
1830
1360
1540
1720
1880
3.5
4.4
5
5.8
85
85
85
85
100.5
100.5
100.5
100.5
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
400
452
560
560
1.Q1322-3BB56-1...
1.Q1322-3BB76-1...
2300
2420
2350
2480
8.3
8.9
85
85
101
101
3300
3300
1XB7 731
1XB7 740
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
560
710
1.Q1322-3AB16-6...
1.Q1322-3AB36-6...
1.Q1322-3AB56-6...
1.Q1322-3AB76-6...
1.Q1322-3BB56-6...
1.Q1322-3BB76-6...
1310
1490
1670
1830
2300
2420
1360
1540
1720
1880
2350
2480
3.5
4.4
5
5.8
8.3
8.9
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
400
452
560
710
710
710
1.Q1322-3AC16-7...
1.Q1322-3AC36-7...
1.Q1322-3AC56-7...
1.Q1322-3AC76-7...
1.Q1322-3BC56-7...
1.Q1322-3BC76-7...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GF33-3AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
320
400
452
560
560
560
1.Q1322-3AC16-8...
1.Q1322-3AC36-8...
1.Q1322-3AC56-8...
1.Q1322-3AC76-8...
1.Q1322-3BC56-8...
1.Q1322-3BC76-8...
1340
1520
1700
1810
2290
2440
1390
1570
1750
1860
2350
2490
5.9
7.2
8.3
9.1
14.5
16
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GF33-3AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
320
400
400
452
452
560
Siemens D 81.8 · 04/2014
5
5/29
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LQ1/1MQ1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V
1800 rpm, 4-pole
5
235
315
315
Δ
60.4
1247
95.2
96.2
95.9
0.86
270
8.5
3.1
1■Q1213-3AB16-6■■■
330
443
315
Δ
60.4
1751
95.6
96.3
96.2
0.86
375
9.4
3.4
1■Q1213-3AB36-6■■■
370
496
315
Δ
60.4
1963
95.7
96.4
96.5
0.88
415
9.1
3.2
1■Q1213-3AB56-6■■■
440
590
315
Δ
60.4
2336
95.9
96.6
96.6
0.87
495
10.3
3.2
1■Q1213-3AB76-6■■■
480
644
355
Δ
60.4
2549
96.2
97.0
96.9
0.86
540
9.2
3.5
1■Q1213-3BB56-6■■■
520
697
355
Δ
60.3
2761
96.3
97.0
97.0
0.85
600
9.9
3.6
1■Q1213-3BB76-6■■■
1200 rpm, 6-pole
240
322
315
Δ
60.5
1911
95.0
95.9
96.0
0.81
290
8.0
2.5
1■Q1213-3AC16-7■■■
285
382
315
Δ
60.4
2269
95.2
96.1
96.1
0.82
340
8.3
2.6
1■Q1213-3AC36-7■■■
325
436
315
Δ
60.5
2588
95.2
96.2
96.3
0.84
380
7.8
2.4
1■Q1213-3AC56-7■■■
355
476
315
Δ
60.4
2826
95.4
96.3
96.3
0.84
415
8.1
2.5
1■Q1213-3AC76-7■■■
400
536
355
Δ
60.3
3183
95.9
96.6
96.4
0.81
485
11.2
3.1
1■Q1213-3BC56-7■■■
440
590
355
Δ
60.3
3502
95.9
96.6
96.5
0.83
520
10.8
2.8
1■Q1213-3BC76-7■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V
1800 rpm, 4-pole
220
295
315
Δ
60.5
1167
95.3
96.2
95.9
0.86
280
8.4
3.1
1■Q1223-3AB16-6■■■
315
422
315
Δ
60.4
1671
95.6
96.3
96.2
0.86
400
9.4
3.4
1■Q1223-3AB36-6■■■
365
489
315
Δ
60.4
1937
95.7
96.4
96.4
0.88
450
9.2
3.2
1■Q1223-3AB56-6■■■
435
583
315
Δ
60.4
2310
96.0
96.7
96.6
0.86
550
10.6
3.2
1■Q1223-3AB76-6■■■
470
630
355
Δ
60.3
2495
96.2
97.0
96.9
0.85
600
9.4
3.7
1■Q1223-3BB56-6■■■
495
664
355
Δ
60.4
2626
96.1
97.0
97.0
0.88
610
8.7
3.3
1■Q1223-3BB76-6■■■
1200 rpm, 6-pole
220
295
315
Δ
60.5
1752
94.8
95.8
95.9
0.82
295
7.5
2.3
1■Q1223-3AC16-7■■■
280
375
315
Δ
60.4
2229
95.2
96.1
96.1
0.82
375
8.2
2.6
1■Q1223-3AC36-7■■■
320
429
315
Δ
60.5
2548
95.3
96.2
96.3
0.84
415
8.0
2.4
1■Q1223-3AC56-7■■■
360
483
315
Δ
60.4
2866
95.4
96.3
96.3
0.84
465
8.3
2.5
1■Q1223-3AC76-7■■■
385
516
355
Δ
60.3
3064
95.9
96.6
96.4
0.82
510
10.8
3.2
1■Q1223-3BC56-7■■■
415
557
355
Δ
60.3
3303
96.0
96.6
96.4
0.80
560
12.2
3.0
1■Q1223-3BC76-7■■■
For versions, see Article No. supplements and special versions
5/30
Siemens D 81.8 · 04/2014
1■M1223-3AC76-7■■■
© Siemens AG 2014
Forced-air cooled motors — enclosed version
1LQ1/1MQ1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.Q1213-3AB16-6...
1310
1360
3.5
79
94.5
3000
1XB7 730
6SL3710-7LG33-3AA3
320
1.Q1213-3AB36-6...
1490
1540
4.4
79
94.5
3000
1XB7 731
6SL3710-7LG34-1AA3
400
1.Q1213-3AB56-6...
1670
1720
5
79
94.5
3000
1XB7 731
6SL3710-7LG34-7AA3
452
1.Q1213-3AB76-6...
1830
1880
5.8
79
94.5
3000
1XB7 731
6SL3710-7LG35-8AA3
560
1.Q1213-3BB56-6...
2300
2350
8.3
79
95
2600
1XB7 731
6SL3710-7LG35-8AA3
560
1.Q1213-3BB76-6...
2420
2480
8.9
79
95
2600
1XB7 740
6SL3710-7LG37-4AA3
710
1.Q1213-3AC16-7...
1340
1390
5.9
79
94.5
2600
1XB7 730
6SL3710-7LG33-3AA3
320
1.Q1213-3AC36-7...
1520
1570
7.2
79
94.5
2600
1XB7 730
6SL3710-7LG34-1AA3
400
1.Q1213-3AC56-7...
1700
1750
8.3
79
94.5
2600
1XB7 731
6SL3710-7LG34-1AA3
400
1.Q1213-3AC76-7...
1810
1860
9.1
79
94.5
2600
1XB7 731
6SL3710-7LG34-7AA3
452
1.Q1213-3BC56-7...
2290
2350
14.5
79
95
2500
1XB7 731
6SL3710-7LG35-8AA3
560
1.Q1213-3BC76-7...
2440
2490
16
79
95
2500
1XB7 731
6SL3710-7LG35-8AA3
560
1.Q1223-3AB16-6...
1310
1360
3.5
79
94.5
3000
1XB7 730
6SL3710-1GF33-3AA3
320
1.Q1223-3AB36-6...
1490
1540
4.4
79
94.5
3000
1XB7 731
6SL3710-1GF34-1AA3
400
1.Q1223-3AB56-6...
1670
1720
5
79
94.5
3000
1XB7 731
6SL3710-1GF34-7AA3
452
1.Q1223-3AB76-6...
1830
1880
5.8
79
94.5
3000
1XB7 731
6SL3710-1GF35-8AA3
560
1.Q1223-3BB56-6...
2300
2350
8.3
79
95
2600
1XB7 740
6SL3710-1GF37-4AA3
710
1.Q1223-3BB76-6...
2420
2480
8.9
79
95
2600
1XB7 740
6SL3710-1GF37-4AA3
710
1.Q1223-3AC16-7...
1340
1390
5.9
79
94.5
2600
1XB7 730
6SL3710-1GF33-3AA3
320
1.Q1223-3AC36-7...
1520
1570
7.2
79
94.5
2600
1XB7 731
6SL3710-1GF34-1AA3
400
1.Q1223-3AC56-7...
1700
1750
8.3
79
94.5
2600
1XB7 731
6SL3710-1GF34-7AA3
452
1.Q1223-3AC76-7...
1810
1860
9.1
79
94.5
2600
1XB7 731
6SL3710-1GF35-8AA3
560
1.Q1223-3BC56-7...
2290
2350
14.5
79
95
2500
1XB7 731
6SL3710-1GF35-8AA3
560
1.Q1223-3BC76-7...
2440
2490
16
79
95
2500
1XB7 731
6SL3710-1GF35-8AA3
560
Siemens D 81.8 · 04/2014
5
5/31
© Siemens AG 2014
Forced-air cooled motors — enclosed version
Dimensions
1LQ1/1MQ1 motors
Radially mounted equipment unit
■ Dimensional drawings
IM B3 type of construction
For terminal box dimensions, see Page 5/35.
HC
L
HB'
HK
LL
BE
HD
ØD
F
HB
AC
AG
AD
BC
GA
EB
H
HA
5
DB
BA
E
G_D081_XX_00424
C
B
BB
ØK
Ø K'
AA
A
AB
IM B35 and IM V1 types of construction
For flange dimensions, see Page 5/34 (Z = the number of retaining holes),
For terminal box dimensions, see Page 5/35
L
HC
LM
HB'
LL
HK
HH
T
HB
ØP
ØN
ØD
F
HD
AG
AC
ZxS
E
GA
AD
BE
M
H
HA
EB
DB
G_D081_XX_00425
BA
LA
LE
ØK
C
Ø K'
B
BB
AA
A
AB
Frame No. of
size
poles
Motor type
315
1.Q12..-3A.1.-....
560 120 680 1155 630 180 780 180 315 28
1.Q12..-3A.3.-.... ● 560 120 680 1155 630 180 780 200 315 28
28 35 1450 1670 85
M20 170 140 22 90
28 35 1470 1690 95
M24 170 140 25 100
1.Q12..-3A.5.-....
560 120 680 1155 835 180 985 180 315 28
1.Q12..-3A.7.-.... ● 560 120 680 1155 835 180 985 200 315 28
28 35 1590 1810 85
M20 170 140 22 90
28 35 1610 1830 95
M24 170 140 25 100
1.Q13.-3A.1.-….
1.Q13.-3A.3.-….
560 120 680 1245 630 180 780 180 315 28
28 35 1450 1765 85
M20 170 140 22 90
● 560 120 680 1245 630 180 780 200 315 28
28 35 1470 1785 95
M24 170 140 25 100
560 120 680 1245 835 180 985 180 315 28
28 35 1590 1905 85
M20 170 140 22 90
● 560 120 680 1245 835 180 985 200 315 28
28 35 1610 1925 95
M24 170 140 25 100
630 150 780 1305 800 220 980 200 355 35
35 42 1725 1975 95
M24 170 140 25 100
4, 6
A
1.Q13.-3A.5.-….
1.Q13.-3A.7.-….
355
4, 6
Dimension designation acc. to IEC
AA
AB
AC
BA
BB
C
H
HA K
1.Q12.-3A.5.-….
1.Q12.-3A.7.-….
● 630 150 780 1305 800 220 980 224 355 35
1.Q13.-3A.5.-….
1.Q13.-3A.7.-….
● 630 150 780 1305 800 220 980 224 355 25
630 150 780 1305 800 220 980 200 355 35
● Bearing design for increased cantilever forces, for type of
construction IM B3 only.
5/32
B
Siemens D 81.8 · 04/2014
1)
K'
L 1)
LM1)
D
DB
E
EB
F
GA
35 42 1790 2040 100 M24 210 180 28 106
35 42 1725 2075 95
M24 170 140 25 100
35 42 1790 2140 100 M24 210 180 28 106
With type of construction IM V1, dimensions L or LM
may increase due to a protective cover for the fan motor.
© Siemens AG 2014
Forced-air cooled motors — enclosed version
Dimensions
1LQ1/1MQ1 motors
Axially mounted equipment unit
■ Dimensional drawings
IM B3 type of construction
For terminal box dimensions, see Page 5/35.
L
LL
BE
HB'
HK
HC
GA
HD
AC
ØD
F
HB
AG
AD
BC
BA
E
5
H
HA
EB
DB
G_D081_XX_00418
C
ØK
B
BB
Ø K'
AA
A
AB
IM B35 and IM V1 types of construction
For flange dimensions, see Page 5/34 (Z = the number of retaining holes),
For terminal box dimensions, see Page 5/35
L
LL
HC
HB'
HK
HH
BE
AG
AD
LM
HB
ZxS
GA
AQ
AC
ØP
ØN
ØD
F
E
DB
G_D081_XX_00419
BA
LA
LE
C
Frame No. of
size
poles
Motor type
315
1.Q12..-3A.1.-....
1.Q12..-3A.3.-....
4, 6
4, 6
1.Q12..-3A.5.-….
1.Q12..-3A.7.-….
ØK
Ø K'
B
BB
AA
A
AB
Dimension designation acc. to IEC
A
1.Q12..-3A.5.-....
1.Q12..-3A.7.-....
355
M
H
HA
EB
HD
T
AA AB
AC AQ B
BA
BB
C
H
HA K
K' L
LM
D
560 120 680 630 670 630 180 780 180 315 28 28 35 1525 1685 85
● 560 120 680 630 670 630 180 780 200 315 28 28 35 1545 1705 95
560 120 680 630 670 835 180 985 180 315 28 28 35 1665 1825 85
DB
E
EB
F
GA
M20 170 140 22 90
M24 170 140 25 100
M20 170 140 22 90
● 560 120 680 630 670 835 180 985 200 315 28 28 35 1685 1845 95
M24 170 140 25 100
630 150 780 710 750 800 220 980 200 355 35 35 42 2115 2300 95
M24 170 140 25 100
● 630 150 780 710 750 800 220 980 224 355 35 35 42 2180 2365 100 M24 210 180 28 106
● Bearing design for increased cantilever forces, for type of construction IM B3 only.
Siemens D 81.8 · 04/2014
5/33
© Siemens AG 2014
Forced-air cooled motors — enclosed version
Dimensions
Flanges
G_D081_XX_00026
■ Dimensional drawings
(Z = the number of retaining holes)
Flange with through holes
Motor type
5
Frame size
No. of poles Type of construction Flange type
Dimension designation acc. to IEC
LA
1LQ1/1MQ1
315
355
5/34
4, 6
4, 6
Siemens D 81.8 · 04/2014
IM B35, IM V1
IM B35, IM V1
LE
M
N
P
S
T
Z
Flange
29
170
740
680
800
22
6
8
Flange (optional)
22
170
600
550
660
22
6
8
Flange
29
170
840
780
900
22
6
8
Flange (optional)
22
170
600
550
660
22
6
8
© Siemens AG 2014
Forced-air cooled motors — enclosed version
Dimensions
Terminal boxes
■ Dimensional drawings
LL
BE
HB'
HK
HC
AG1
IM B3 type of construction
HD
HB
AG
AD
BC
5
G_D081_XX_00426
LL
HC
HB'
HK
HH
AG1
IM B35 and IM V1 types of construction
HD
HB
AG
AD
BE
G_D081_XX_00427
Motor
type
Frame
size
No. of
poles
Terminal box
Dimension designation acc. to IEC
AD
AG
AG1
BC
BE
HB
HB'
HH
HC
HD
HK
LL
1LQ1/
1MQ1
315
4, 6
1XB7 730
710
575
–
115
–
890
310
295
180
1025
255
345
1XB7 731
710
575
–
115
115
890
310
295
180
1025
255
345
1XB7 740
800
615
60
115
150
930
365
295
235
1110
340
425
GT640
655
555
–
115
110
870
225
295
155
970
170
310
1XB1 621
705
585
–
115
150
900
305
295
165
1020
250
330
1XB1 631
775
640
–
115
100
955
400
295
175
1090
320
555
1XB7 730
750
615
–
100
–
970
310
300
180
1105
255
345
1XB7 731
750
615
–
100
115
970
310
300
180
1105
255
345
1XB7 740
840
655
60
100
150
1010
365
300
235
1190
340
425
GT640
695
595
–
100
110
950
225
300
155
1050
170
310
1XB1 621
745
625
–
100
150
980
305
300
165
1100
250
330
1XB1 631
815
680
–
100
100
1035
400
300
175
1170
320
555
355
4, 6
Siemens D 81.8 · 04/2014
5/35
© Siemens AG 2014
Forced-air cooled motors — enclosed version
Dimensions
Notes
5
5/36
Siemens D 81.8 · 04/2014
6
© Siemens AG 2014
Water-cooled motors
with water-jacket cooling
6/2
6/2
6/2
6/4
6/6
6/6
6/8
6/10
6/10
6/12
6/14
6/14
6/16
6/18
6/18
6/20
6/22
1LH1/1MH1 motors for
converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
Premium Efficiency
Line voltage 500 V, 50 Hz
High Efficiency
Premium Efficiency
Line voltage 690 V, 50 Hz
High Efficiency
Premium Efficiency
Line voltage 460 V, 60 Hz
High Efficiency
Premium Efficiency
Line voltage 575 V, 60 Hz
High Efficiency
Premium Efficiency
6/22
6/22
6/24
6/26
6/26
6/28
6/30
6/30
6/32
1LH1/1MH1 motors for
mains-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
Premium Efficiency
Line voltage 690 V, 50 Hz
High Efficiency
Premium Efficiency
Line voltage 460 V, 60 Hz
High Efficiency
Premium Efficiency
6/34
6/34
6/35
6/36
Dimensions
1LH1/1MH1 motors
Flanges
Terminal boxes
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
■ Selection and ordering data
6
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LH1/1MH1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V
3000 rpm, 4-pole
330
443
315
Δ
100.9 1051
94.5
95.3
95.2
0.88
530
4.7
1.6
1■H1212-3AB11-1■■■
1■H1212-3AB31-1■■■
410
550
315
Δ
100.8 1306
95.0
95.7
95.6
0.89
650
5.1
1.7
460
617
315
Δ
100.8 1465
95.2
95.8
95.6
0.90
720
5.5
1.8
1■H1212-3AB51-1■■■
535
717
315
Δ
100.8 1704
95.4
96.1
95.9
0.91
830
5.8
1.9
1■H1212-3AB71-1■■■
1■H1212-3BB51-1■■■
560
751
355
Δ
100.7 1783
95.3
95.9
95.6
0.89
890
5.3
1.9
575
771
355
Δ
100.7 1832
95.2
95.9
95.7
0.89
920
4.7
1.7
1■H1212-3BB71-1■■■
1500 rpm, 4-pole
310
416
315
Δ
50.7
1974
94.0
95.2
95.7
0.88
500
5.7
2.1
1■H1212-3AB11-2■■■
405
543
315
Δ
50.6
2579
94.6
95.7
96.0
0.89
650
6.4
2.3
1■H1212-3AB31-2■■■
445
597
315
Δ
50.6
2834
94.6
95.7
96.0
0.90
700
6.6
2.3
1■H1212-3AB51-2■■■
510
684
315
Δ
50.6
3248
94.7
95.8
96.1
0.90
800
6.5
2.3
1■H1212-3AB71-2■■■
560
751
355
Δ
50.6
3566
94.9
96.0
96.4
0.89
890
5.7
2.2
1■H1212-3BB51-2■■■
630
845
355
Δ
50.5
4012
95.2
96.2
96.5
0.89
1000
6.3
2.4
1■H1212-3BB71-2■■■
1000 rpm, 6-pole
260
349
315
Δ
50.6
2483
94.1
95.2
95.6
0.81
460
6.2
2.0
1■H1212-3AC11-3■■■
320
429
315
Δ
50.6
3058
94.3
95.4
95.8
0.83
550
6.3
2.0
1■H1212-3AC31-3■■■
370
496
315
Δ
50.6
3534
94.4
95.5
95.9
0.84
630
6.1
1.9
1■H1212-3AC51-3■■■
1■H1212-3AC71-3■■■
415
557
315
Δ
50.6
3965
94.6
95.7
96.0
0.84
700
6.6
1.9
495
664
355
Δ
50.5
4729
94.5
95.6
95.8
0.86
820
7.0
2.1
1■H1212-3BC51-3■■■
565
758
355
Δ
50.4
5398
94.8
95.8
95.9
0.86
930
7.8
1.8
1■H1212-3BC71-3■■■
750 rpm, 6-pole
205
275
315
Δ
38.1
2611
92.9
94.3
94.8
0.81
365
6.1
2.0
1■H1212-3AC11-4■■■
265
355
315
Δ
38.1
3377
93.1
94.5
95.1
0.83
460
5.9
1.9
1■H1212-3AC31-4■■■
300
402
315
Δ
38.2
3821
93.1
94.5
95.2
0.84
510
5.5
1.8
1■H1212-3AC51-4■■■
335
449
315
Δ
38.1
4267
93.2
94.7
95.3
0.85
570
5.5
1.7
1■H1212-3AC71-4■■■
380
510
355
Δ
38
4839
93.3
94.6
95.1
0.87
630
6.3
2.0
1■H1212-3BC51-4■■■
425
570
355
Δ
38
5412
93.5
94.8
95.3
0.87
700
6.5
1.8
1■H1212-3BC71-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V
3000 rpm, 4-pole
320
429
315
Δ
100.9 1020
94.5
95.3
95.1
0.88
580
4.7
1.6
1■H1222-3AB11-1■■■
1■H1222-3AB31-1■■■
410
550
315
Δ
100.8 1306
95.1
95.8
95.6
0.90
720
5.4
1.8
465
624
315
Δ
100.7 1481
95.3
95.9
95.7
0.90
820
5.9
2.0
1■H1222-3AB51-1■■■
480
644
315
Δ
100.9 1529
95.1
95.8
95.7
0.90
850
5.0
1.7
1■H1222-3AB71-1■■■
565
758
355
Δ
100.6 1799
95.5
96.0
95.6
0.89
1000
6.1
2.2
1■H1222-3BB51-1■■■
585
784
355
Δ
100.6 1863
95.4
96.0
95.7
0.89
1040
5.4
2.0
1■H1222-3BB71-1■■■
1500 rpm, 4-pole
320
429
315
Δ
50.6
2038
94.3
95.4
95.7
0.87
590
6.0
2.2
1■H1222-3AB11-2■■■
400
536
315
Δ
50.6
2548
94.5
95.6
96.0
0.89
710
6.4
2.3
1■H1222-3AB31-2■■■
450
603
315
Δ
50.6
2866
94.6
95.7
96.0
0.90
790
6.6
2.3
1■H1222-3AB51-2■■■
520
697
315
Δ
50.6
3311
94.8
95.8
96.1
0.90
920
6.6
2.2
1■H1222-3AB71-2■■■
565
758
355
Δ
50.6
3598
95.0
96.1
96.4
0.89
1000
6.0
2.3
1■H1222-3BB51-2■■■
650
872
355
Δ
50.5
4139
95.3
96.3
96.5
0.89
1160
6.7
2.4
1■H1222-3BB71-2■■■
1000 rpm, 6-pole
260
349
315
Δ
50.6
2483
94.0
95.1
95.5
0.82
510
6.0
1.9
1■H1222-3AC11-3■■■
325
436
315
Δ
50.6
3105
94.3
95.4
95.8
0.83
620
6.3
2.0
1■H1222-3AC31-3■■■
370
496
315
Δ
50.6
3536
94.5
95.6
95.9
0.84
700
6.4
2.0
1■H1222-3AC51-3■■■
1■H1222-3AC71-3■■■
420
563
315
Δ
50.6
4011
94.5
95.6
96.0
0.85
790
6.0
1.8
505
677
355
Δ
50.5
4825
94.7
95.7
95.8
0.86
930
7.6
2.1
1■H1222-3BC51-3■■■
560
751
355
Δ
50.5
5351
94.8
95.8
95.9
0.87
1020
7.5
1.9
1■H1222-3BC71-3■■■
750 rpm, 6-pole
220
295
315
Δ
38.2
2803
92.9
94.2
94.9
0.81
440
5.7
1.9
1■H1222-3AC11-4■■■
270
362
315
Δ
38.1
3442
93.2
94.5
95.1
0.82
530
6.0
2.0
1■H1222-3AC31-4■■■
305
409
315
Δ
38.1
3884
93.2
94.6
95.2
0.83
590
5.8
1.9
1■H1222-3AC51-4■■■
330
443
315
Δ
38.1
4203
93.2
94.6
95.3
0.85
620
5.7
1.8
1■H1222-3AC71-4■■■
380
510
355
Δ
38
4839
93.3
94.7
95.2
0.87
700
6.3
2.0
1■H1222-3BC51-4■■■
430
577
355
Δ
38
5475
93.6
94.8
95.3
0.87
790
6.6
1.8
1■H1222-3BC71-4■■■
For versions, see Article No. supplements and special versions
1■H1222-3AC71-4■■■
Prated
6/2
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
LpfA,
LWA,
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
tolerance
+3 dB(A)
no-load
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.H1212-3AB11-1...
1.H1212-3AB31-1...
1.H1212-3AB51-1...
1.H1212-3AB71-1...
1.H1212-3BB51-1...
1.H1212-3BB71-1...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-0AA3
590
725
725
960
960
960
1.H1212-3AB11-2...
1.H1212-3AB31-2...
1.H1212-3AB51-2...
1.H1212-3AB71-2...
1.H1212-3BB51-2...
1.H1212-3BB71-2...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
590
725
725
820
960
1230
1.H1212-3AC11-3...
1.H1212-3AC31-3...
1.H1212-3AC51-3...
1.H1212-3AC71-3...
1.H1212-3BC51-3...
1.H1212-3BC71-3...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
477
590
725
725
820
960
1.H1212-3AC11-4...
1.H1212-3AC31-4...
1.H1212-3AC51-4...
1.H1212-3AC71-4...
1.H1212-3BC51-4...
1.H1212-3BC71-4...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LE33-8AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
370
477
590
590
725
725
1.H1222-3AB11-1...
1.H1222-3AB31-1...
1.H1222-3AB51-1...
1.H1222-3AB71-1...
1.H1222-3BB51-1...
1.H1222-3BB71-1...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-1AA3
590
725
820
960
1092
1092
1.H1222-3AB11-2...
1.H1222-3AB31-2...
1.H1222-3AB51-2...
1.H1222-3AB71-2...
1.H1222-3BB51-2...
1.H1222-3BB71-2...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-4AA3
590
725
820
960
1092
1340
1.H1222-3AC11-3...
1.H1222-3AC31-3...
1.H1222-3AC51-3...
1.H1222-3AC71-3...
1.H1222-3BC51-3...
1.H1222-3BC71-3...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
590
725
725
820
960
1092
1.H1222-3AC11-4...
1.H1222-3AC31-4...
1.H1222-3AC51-4...
1.H1222-3AC71-4...
1.H1222-3BC51-4...
1.H1222-3BC71-4...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
477
590
590
725
725
820
Siemens D 81.8 · 04/2014
6/3
6
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LH1/1MH1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V
1500 rpm, 4-pole
225
302
315
Δ
50.5
1433
95.1
96.0
96.1
0.86
370
7.7
2.9
1■H1213-3AB11-2■■■
365
489
315
Δ
50.6
2324
95.0
96.0
96.3
0.88
590
7.0
2.6
1■H1213-3AB31-2■■■
400
536
315
Δ
50.6
2547
95.0
96.0
96.2
0.89
640
7.2
2.6
1■H1213-3AB51-2■■■
480
644
315
Δ
50.6
3057
94.9
96.0
96.3
0.90
750
7.0
2.4
1■H1213-3AB71-2■■■
570
764
355
Δ
50.6
3630
95.0
96.2
96.6
0.89
900
5.6
2.1
1■H1213-3BB51-2■■■
645
865
355
Δ
50.6
4107
95.3
96.4
96.7
0.89
1020
6.2
2.3
1■H1213-3BB71-2■■■
1000 rpm, 6-pole
6
210
282
315
Δ
50.5
2006
94.8
95.8
95.9
0.80
370
7.7
2.5
1■H1213-3AC11-3■■■
290
389
315
Δ
50.5
2771
94.7
95.8
96.0
0.83
495
7.0
2.2
1■H1213-3AC31-3■■■
335
449
315
Δ
50.5
3201
94.8
95.9
96.2
0.84
560
6.8
2.1
1■H1213-3AC51-3■■■
410
550
315
Δ
50.6
3918
94.7
95.8
96.1
0.84
690
6.6
1.9
1■H1213-3AC71-3■■■
510
684
355
Δ
50.5
4871
94.7
95.8
96.1
0.86
840
6.8
2.0
1■H1213-3BC51-3■■■
580
778
355
Δ
50.5
5541
95.0
96.1
96.3
0.85
960
7.6
1.8
1■H1213-3BC71-3■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V
1500 rpm, 4-pole
245
329
315
Δ
50.5
1560
95.1
96.0
96.1
0.85
455
7.9
3.0
1■H1223-3AB11-2■■■
360
483
315
Δ
50.6
2293
94.9
96.0
96.3
0.88
650
7.0
2.6
1■H1223-3AB31-2■■■
405
543
315
Δ
50.6
2579
95.0
96.0
96.3
0.89
720
7.3
2.6
1■H1223-3AB51-2■■■
495
664
315
Δ
50.6
3152
94.9
96.0
96.3
0.90
870
7.0
2.3
1■H1223-3AB71-2■■■
580
778
355
Δ
50.6
3694
95.1
96.2
96.6
0.89
1020
5.8
2.2
1■H1223-3BB51-2■■■
670
898
355
Δ
50.5
4266
95.4
96.5
96.8
0.88
1200
6.4
2.3
1■H1223-3BB71-2■■■
1000 rpm, 6-pole
205
275
315
Δ
50.5
1959
94.8
95.8
95.9
0.81
400
7.6
2.4
1■H1223-3AC11-3■■■
295
396
315
Δ
50.5
2819
94.7
95.8
96.0
0.82
570
6.9
2.2
1■H1223-3AC31-3■■■
345
463
315
Δ
50.5
3296
94.7
95.8
96.1
0.83
660
6.8
2.1
1■H1223-3AC51-3■■■
405
543
315
Δ
50.6
3870
94.6
95.8
96.1
0.84
760
6.3
1.9
1■H1223-3AC71-3■■■
515
691
355
Δ
50.5
4921
94.9
95.9
96.2
0.85
960
7.3
2.0
1■H1223-3BC51-3■■■
575
771
355
Δ
50.5
5494
94.9
96.0
96.3
0.86
1060
7.2
1.8
1■H1223-3BC71-3■■■
For versions, see Article No. supplements and special versions
6/4
Siemens D 81.8 · 04/2014
1■H1223-3AC71-3■■■
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.H1213-3AB11-2...
1240
1290
3.5
78
93
3000
1XB7 731
6SL3710-7LE33-8AA3
370
1.H1213-3AB31-2...
1420
1470
4.4
78
93
3000
1XB7 731
6SL3710-7LE36-1AA3
590
1.H1213-3AB51-2...
1600
1650
5.0
78
93
3000
1XB7 740
6SL3710-7LE37-5AA3
725
1.H1213-3AB71-2...
1770
1820
5.8
78
93
3000
1XB7 740
6SL3710-7LE38-4AA3
820
1.H1213-3BB51-2...
2200
2250
8.3
78
93.5
2600
1XB7 740
6SL3710-7LE41-0AA3
960
1.H1213-3BB71-2...
2320
2380
8.9
78
93.5
2600
1XB7 740
6SL3710-7LE41-2AA3
1230
1.H1213-3AC11-3...
1270
1320
5.9
78
93
2600
1XB7 731
6SL3710-7LE33-8AA3
370
1.H1213-3AC31-3...
1450
1500
7.2
78
93
2600
1XB7 731
6SL3710-7LE36-1AA3
590
1.H1213-3AC51-3...
1630
1680
8.3
78
93
2600
1XB7 731
6SL3710-7LE36-1AA3
590
1.H1213-3AC71-3...
1740
1790
9.1
78
93
2600
1XB7 740
6SL3710-7LE37-5AA3
725
1.H1213-3BC51-3...
2190
2250
14.5
78
93.5
2500
1XB7 740
6SL3710-7LE41-0AA3
960
1.H1213-3BC71-3...
2340
2390
16.0
78
93.5
2500
1XB7 740
6SL3710-7LE41-0AA3
960
1.H1223-3AB11-2...
1240
1290
3.5
78
93
3000
1XB7 731
6SL3710-1GE35-0AA3
477
1.H1223-3AB31-2...
1420
1470
4.4
78
93
3000
1XB7 740
6SL3710-1GE37-5AA3
725
1.H1223-3AB51-2...
1600
1650
5.0
78
93
3000
1XB7 740
6SL3710-1GE37-5AA3
725
1.H1223-3AB71-2...
1770
1820
5.8
78
93
3000
1XB7 740
6SL3710-1GE41-0AA3
960
1.H1223-3BB51-2...
2200
2250
8.3
78
93.5
2600
1XB7 740
6SL3710-2GE41-1AA3
1092
1.H1223-3BB71-2...
2320
2380
8.9
78
93.5
2600
2 x 1XB7 740 6SL3710-2GE41-4AA3
1340
1.H1223-3AC11-3...
1270
1320
5.9
78
93
2600
1XB7 731
6SL3710-1GE35-0AA3
477
1.H1223-3AC31-3...
1450
1500
7.2
78
93
2600
1XB7 731
6SL3710-1GE36-1AA3
590
1.H1223-3AC51-3...
1630
1680
8.3
78
93
2600
1XB7 740
6SL3710-1GE37-5AA3
725
1.H1223-3AC71-3...
1740
1790
9.1
78
93
2600
1XB7 740
6SL3710-1GE38-4AA3
820
1.H1223-3BC51-3...
2190
2250
14.5
78
93.5
2500
1XB7 740
6SL3710-1GE41-0AA3
1.H1223-3BC71-3...
2340
2390
16.0
78
93.5
2500
2 x 1XB7 740 6SL3710-2GE41-1AA3
Siemens D 81.8 · 04/2014
6
960
1092
6/5
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency
■ Selection and ordering data
6
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LH1/1MH1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V
3000 rpm, 4-pole
305
409
315
Δ
100.8 971
94.6
95.2
95.0
0.89
400
5.3
1.8
1■H1212-3AB12-1■■■
1■H1212-3AB32-1■■■
405
543
315
Δ
100.7 1290
95.2
95.8
95.6
0.90
520
6.3
2.1
450
603
315
Δ
100.7 1433
95.3
95.8
95.6
0.90
580
6.5
2.1
1■H1212-3AB52-1■■■
470
630
315
Δ
100.8 1497
95.1
95.8
95.6
0.90
610
5.4
1.8
1■H1212-3AB72-1■■■
1■H1212-3BB52-1■■■
545
731
355
Δ
100.6 1736
95.3
95.9
95.5
0.89
710
5.9
2.1
570
764
355
Δ
100.7 1815
95.2
95.9
95.6
0.89
740
5.3
1.9
1■H1212-3BB72-1■■■
1500 rpm, 4-pole
285
382
315
Δ
50.7
1815
94.0
95.2
95.6
0.88
380
6.0
2.2
1■H1212-3AB12-2■■■
360
483
315
Δ
50.6
2293
94.3
95.5
95.9
0.89
470
6.4
2.3
1■H1212-3AB32-2■■■
420
563
315
Δ
50.6
2675
94.6
95.6
95.9
0.90
540
7.1
2.5
1■H1212-3AB52-2■■■
505
677
315
Δ
50.5
3215
95.0
95.9
96.1
0.89
660
7.7
2.3
1■H1212-3AB72-2■■■
560
751
355
Δ
50.5
3566
95.1
96.1
96.3
0.88
740
6.7
2.6
1■H1212-3BB52-2■■■
620
831
355
Δ
50.5
3948
95.3
96.3
96.4
0.88
810
7.3
2.5
1■H1212-3BB72-2■■■
1000 rpm, 6-pole
250
335
315
Δ
50.6
2389
94.0
95.2
95.5
0.82
355
6.5
2.1
1■H1212-3AC12-3■■■
300
402
315
Δ
50.6
2867
94.2
95.3
95.6
0.83
420
6.7
2.1
1■H1212-3AC32-3■■■
335
449
315
Δ
50.6
3202
94.2
95.4
95.7
0.84
465
6.4
2.0
1■H1212-3AC52-3■■■
1■H1212-3AC72-3■■■
375
503
315
Δ
50.6
3584
94.4
95.5
95.8
0.85
510
6.6
2.0
460
617
355
Δ
50.4
4396
94.5
95.5
95.7
0.86
620
7.7
2.3
1■H1212-3BC52-3■■■
515
691
355
Δ
50.4
4920
94.7
95.7
95.7
0.86
690
8.2
2.0
1■H1212-3BC72-3■■■
750 rpm, 6-pole
200
268
315
Δ
38.1
2547
92.7
94.1
94.6
0.80
295
6.2
2.1
1■H1212-3AC12-4■■■
245
329
315
Δ
38.1
3120
93.0
94.4
94.9
0.82
350
6.3
2.1
1■H1212-3AC32-4■■■
270
362
315
Δ
38.1
3440
92.9
94.3
95.0
0.84
380
5.8
1.9
1■H1212-3AC52-4■■■
310
416
315
Δ
38.1
3949
93.1
94.5
95.1
0.84
435
6.0
1.9
1■H1212-3AC72-4■■■
365
489
355
Δ
37.9
4650
93.5
94.7
95.1
0.86
500
7.2
2.1
1■H1212-3BC52-4■■■
390
523
355
Δ
38
4967
93.4
94.7
95.1
0.87
530
6.8
2.0
1■H1212-3BC72-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V
3000 rpm, 4-pole
330
443
315
Δ
100.8 1051
94.7
95.4
95.2
0.88
475
4.9
1.7
1■H1222-3AB12-1■■■
1■H1222-3AB32-1■■■
415
557
315
Δ
100.8 1322
95.0
95.7
95.6
0.89
590
5.1
1.7
460
617
315
Δ
100.8 1465
95.1
95.8
95.6
0.90
640
5.4
1.8
1■H1222-3AB52-1■■■
520
697
315
Δ
100.8 1656
95.3
96.0
95.8
0.91
720
5.6
1.8
1■H1222-3AB72-1■■■
545
731
355
Δ
100.7 1736
95.2
95.9
95.6
0.89
770
5.0
1.8
1■H1222-3BB52-1■■■
615
825
355
Δ
100.6 1958
95.5
96.1
95.8
0.89
860
5.8
2.1
1■H1222-3BB72-1■■■
1500 rpm, 4-pole
305
409
315
Δ
50.7
1942
93.9
95.2
95.6
0.88
440
5.5
2.0
1■H1222-3AB12-2■■■
415
557
315
Δ
50.6
2643
94.6
95.7
96.0
0.88
590
6.6
2.4
1■H1222-3AB32-2■■■
455
610
315
Δ
50.6
2897
94.7
95.7
96.0
0.90
640
6.6
2.4
1■H1222-3AB52-2■■■
510
684
315
Δ
50.6
3248
94.7
95.8
96.1
0.90
710
6.6
2.3
1■H1222-3AB72-2■■■
615
825
355
Δ
50.5
3916
95.3
96.3
96.4
0.88
870
6.7
2.5
1■H1222-3BB52-2■■■
630
845
355
Δ
50.6
4012
95.2
96.2
96.5
0.89
890
6.1
2.3
1■H1222-3BB72-2■■■
1000 rpm, 6-pole
255
342
315
Δ
50.7
2436
93.8
95.1
95.5
0.82
395
5.7
1.8
1■H1222-3AC12-3■■■
330
443
315
Δ
50.6
3153
94.3
95.4
95.8
0.83
500
6.4
2.0
1■H1222-3AC32-3■■■
370
496
315
Δ
50.6
3534
94.4
95.5
95.9
0.84
550
6.2
1.9
1■H1222-3AC52-3■■■
1■H1222-3AC72-3■■■
415
557
315
Δ
50.6
3965
94.6
95.7
96.0
0.84
620
6.4
1.9
495
664
355
Δ
50.5
4730
94.5
95.5
95.8
0.86
720
6.9
2.1
1■H1222-3BC52-3■■■
560
751
355
Δ
50.5
5351
94.7
95.7
95.9
0.87
810
7.4
1.9
1■H1222-3BC72-3■■■
750 rpm, 6-pole
215
288
315
Δ
38.2
2740
92.6
94.1
94.8
0.81
340
5.6
1.9
1■H1222-3AC12-4■■■
265
355
315
Δ
38.1
3374
93.1
94.4
95.0
0.83
405
5.9
1.9
1■H1222-3AC32-4■■■
295
396
315
Δ
38.2
3757
92.9
94.4
95.1
0.84
445
5.4
1.8
1■H1222-3AC52-4■■■
315
422
315
Δ
38.1
4012
93.1
94.6
95.2
0.85
470
5.6
1.8
1■H1222-3AC72-4■■■
390
523
355
Δ
38
4966
93.4
94.7
95.2
0.87
570
6.4
2.0
1■H1222-3BC52-4■■■
430
577
355
Δ
38
5476
93.5
94.8
95.3
0.87
630
6.5
1.8
1■H1222-3BC72-4■■■
For versions, see Article No. supplements and special versions
1■H1222-3AC72-4■■■
Prated
6/6
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.H1212-3AB12-1...
1.H1212-3AB32-1...
1.H1212-3AB52-1...
1.H1212-3AB72-1...
1.H1212-3BB52-1...
1.H1212-3BB72-1...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
400
560
710
710
710
790
1.H1212-3AB12-2...
1.H1212-3AB32-2...
1.H1212-3AB52-2...
1.H1212-3AB72-2...
1.H1212-3BB52-2...
1.H1212-3BB72-2...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
6SL3710-7LG38-8AA3
400
560
560
710
790
880
1.H1212-3AC12-3...
1.H1212-3AC32-3...
1.H1212-3AC52-3...
1.H1212-3AC72-3...
1.H1212-3BC52-3...
1.H1212-3BC72-3...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
400
452
560
560
710
710
1.H1212-3AC12-4...
1.H1212-3AC32-4...
1.H1212-3AC52-4...
1.H1212-3AC72-4...
1.H1212-3BC52-4...
1.H1212-3BC72-4...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
320
400
400
452
560
560
1.H1222-3AB12-1...
1.H1222-3AB32-1...
1.H1222-3AB52-1...
1.H1222-3AB72-1...
1.H1222-3BB52-1...
1.H1222-3BB72-1...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
477
590
725
725
820
960
1.H1222-3AB12-2...
1.H1222-3AB32-2...
1.H1222-3AB52-2...
1.H1222-3AB72-2...
1.H1222-3BB52-2...
1.H1222-3BB72-2...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE41-0AA3
6SL3710-1GE41-0AA3
477
590
725
725
960
960
1.H1222-3AC12-3...
1.H1222-3AC32-3...
1.H1222-3AC52-3...
1.H1222-3AC72-3...
1.H1222-3BC52-3...
1.H1222-3BC72-3...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
477
590
590
725
725
820
1.H1222-3AC12-4...
1.H1222-3AC32-4...
1.H1222-3AC52-4...
1.H1222-3AC72-4...
1.H1222-3BC52-4...
1.H1222-3BC72-4...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
370
477
477
477
590
725
Siemens D 81.8 · 04/2014
6
6/7
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LH1/1MH1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V
1500 rpm, 4-pole
210
282
315
Δ
50.5
1337
94.9
96.0
95.9
0.86
280
8.2
3.0
1■H1213-3AB12-2■■■
290
389
315
Δ
50.5
1846
95.0
96.0
96.2
0.88
380
7.8
2.8
1■H1213-3AB32-2■■■
365
489
315
Δ
50.5
2324
95.0
96.0
96.2
0.89
475
8.0
2.8
1■H1213-3AB52-2■■■
505
677
315
Δ
50.5
3215
95.0
96.0
96.2
0.89
660
7.7
2.3
1■H1213-3AB72-2■■■
575
771
355
Δ
50.5
3662
95.2
96.3
96.6
0.88
750
6.6
2.5
1■H1213-3BB52-2■■■
640
858
355
Δ
50.5
4075
95.4
96.5
96.7
0.88
840
7.1
2.4
1■H1213-3BB72-2■■■
1000 rpm, 6-pole
6
195
261
315
Δ
50.4
1863
94.7
95.7
95.8
0.80
285
8.1
2.7
1■H1213-3AC12-3■■■
260
349
315
Δ
50.5
2484
94.7
95.8
95.9
0.82
365
7.7
2.4
1■H1213-3AC32-3■■■
300
402
315
Δ
50.5
2867
94.7
95.8
96.0
0.84
415
7.1
2.2
1■H1213-3AC52-3■■■
340
456
315
Δ
50.5
3248
94.8
95.8
96.1
0.84
470
7.1
2.2
1■H1213-3AC72-3■■■
470
630
355
Δ
50.5
4491
94.7
95.8
96.1
0.86
630
7.5
2.2
1■H1213-3BC52-3■■■
530
711
355
Δ
50.4
5064
94.9
95.9
96.1
0.86
710
7.9
2.0
1■H1213-3BC72-3■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V
1500 rpm, 4-pole
220
295
315
Δ
50.5
1401
94.9
96.0
96.0
0.87
315
7.6
2.8
1■H1223-3AB12-2■■■
370
496
315
Δ
50.5
2356
95.1
96.0
96.3
0.88
530
7.3
2.7
1■H1223-3AB32-2■■■
410
550
315
Δ
50.6
2611
95.1
96.0
96.3
0.89
580
7.3
2.6
1■H1223-3AB52-2■■■
470
630
315
Δ
50.6
2993
94.9
96.0
96.3
0.90
650
7.2
2.5
1■H1223-3AB72-2■■■
630
845
355
Δ
50.5
4012
95.4
96.4
96.7
0.88
890
6.6
2.5
1■H1223-3BB52-2■■■
645
865
355
Δ
50.6
4108
95.2
96.3
96.7
0.89
910
6.0
2.3
1■H1223-3BB72-2■■■
1000 rpm, 6-pole
195
261
315
Δ
50.5
1863
94.8
95.8
95.9
0.81
300
7.6
2.4
1■H1223-3AC12-3■■■
295
396
315
Δ
50.5
2819
94.7
95.8
96.0
0.82
450
7.1
2.2
1■H1223-3AC32-3■■■
335
449
315
Δ
50.5
3201
94.8
95.9
96.1
0.84
500
6.8
2.1
1■H1223-3AC52-3■■■
405
543
315
Δ
50.6
3870
94.7
95.8
96.1
0.84
610
6.5
1.9
1■H1223-3AC72-3■■■
505
677
355
Δ
50.5
4823
94.6
95.8
96.1
0.86
740
6.7
2.1
1■H1223-3BC52-3■■■
575
771
355
Δ
50.5
5495
94.9
96.0
96.2
0.86
840
7.1
1.8
1■H1223-3BC72-3■■■
For versions, see Article No. supplements and special versions
6/8
Siemens D 81.8 · 04/2014
1■H1223-3AC72-3■■■
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.H1213-3AB12-2...
1240
1290
3.5
78
93
3000
1XB7 730
6SL3710-7LG33-3AA3
320
1.H1213-3AB32-2...
1420
1470
4.4
78
93
3000
1XB7 731
6SL3710-7LG34-1AA3
400
1.H1213-3AB52-2...
1600
1650
5.0
78
93
3000
1XB7 731
6SL3710-7LG35-8AA3
560
1.H1213-3AB72-2...
1770
1820
5.8
78
93
3000
1XB7 740
6SL3710-7LG37-4AA3
710
1.H1213-3BB52-2...
2200
2250
8.3
78
93.5
2600
1XB7 740
6SL3710-7LG38-1AA3
790
1.H1213-3BB72-2...
2320
2380
8.9
78
93.5
2600
1XB7 740
6SL3710-7LG38-8AA3
880
1.H1213-3AC12-3...
1270
1320
5.9
78
93
2600
1XB7 730
6SL3710-7LG33-3AA3
320
1.H1213-3AC32-3...
1450
1500
7.2
78
93
2600
1XB7 731
6SL3710-7LG34-1AA3
400
1.H1213-3AC52-3...
1630
1680
8.3
78
93
2600
1XB7 731
6SL3710-7LG34-7AA3
452
1.H1213-3AC72-3...
1740
1790
9.1
78
93
2600
1XB7 731
6SL3710-7LG35-8AA3
560
1.H1213-3BC52-3...
2190
2250
14.5
78
93.5
2500
1XB7 740
6SL3710-7LG37-4AA3
710
1.H1213-3BC72-3...
2340
2390
16.0
78
93.5
2500
1XB7 740
6SL3710-7LG37-4AA3
710
1.H1223-3AB12-2...
1240
1290
3.5
78
93
3000
1XB7 730
6SL3710-1GE33-8AA3
370
1.H1223-3AB32-2...
1420
1470
4.4
78
93
3000
1XB7 731
6SL3710-1GE36-1AA3
590
1.H1223-3AB52-2...
1600
1650
5.0
78
93
3000
1XB7 731
6SL3710-1GE36-1AA3
590
1.H1223-3AB72-2...
1770
1820
5.8
78
93
3000
1XB7 740
6SL3710-1GE37-5AA3
725
1.H1223-3BB52-2...
2200
2250
8.3
78
93.5
2600
1XB7 740
6SL3710-1GE41-0AA3
960
1.H1223-3BB72-2...
2320
2380
8.9
78
93.5
2600
1XB7 740
6SL3710-1GE41-0AA3
960
1.H1223-3AC12-3...
1270
1320
5.9
78
93
2600
1XB7 730
6SL3710-1GE33-1AA3
302
1.H1223-3AC32-3...
1450
1500
7.2
78
93
2600
1XB7 731
6SL3710-1GE35-0AA3
477
1.H1223-3AC52-3...
1630
1680
8.3
78
93
2600
1XB7 731
6SL3710-1GE36-1AA3
590
1.H1223-3AC72-3...
1740
1790
9.1
78
93
2600
1XB7 740
6SL3710-1GE37-5AA3
725
1.H1223-3BC52-3...
2190
2250
14.5
78
93.5
2500
1XB7 740
6SL3710-1GE38-4AA3
820
1.H1223-3BC72-3...
2340
2390
16.0
78
93.5
2500
1XB7 740
6SL3710-1GE41-0AA3
960
Siemens D 81.8 · 04/2014
6
6/9
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency
■ Selection and ordering data
6
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LH1/1MH1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V
3000 rpm, 4-pole
310
416
315
Δ
100.8 987
94.5
95.2
95.0
0.88
295
5.0
1.7
1■H1212-3AB13-1■■■
1■H1212-3AB33-1■■■
405
543
315
Δ
100.7 1290
95.1
95.7
95.5
0.90
370
5.9
2.0
465
624
315
Δ
100.7 1480
95.3
95.9
95.6
0.90
425
6.6
2.2
1■H1212-3AB53-1■■■
520
697
315
Δ
100.7 1656
95.4
96.0
95.8
0.91
470
6.4
2.1
1■H1212-3AB73-1■■■
1■H1212-3BB53-1■■■
560
751
355
Δ
100.6 1783
95.3
95.9
95.6
0.89
520
5.6
2.0
580
778
355
Δ
100.7 1847
95.2
95.9
95.6
0.89
540
5.0
1.8
1■H1212-3BB73-1■■■
1500 rpm, 4-pole
290
389
315
Δ
50.6
1847
94.0
95.2
95.6
0.88
275
6.2
2.2
1■H1212-3AB13-2■■■
375
503
315
Δ
50.6
2388
94.5
95.6
95.9
0.88
355
6.9
2.5
1■H1212-3AB33-2■■■
430
577
315
Δ
50.6
2738
94.7
95.7
96.0
0.89
400
7.2
2.6
1■H1212-3AB53-2■■■
490
657
315
Δ
50.5
3120
94.9
95.8
96.1
0.90
450
7.6
2.4
1■H1212-3AB73-2■■■
555
744
355
Δ
50.5
3534
95.1
96.1
96.3
0.89
510
6.5
2.5
1■H1212-3BB53-2■■■
600
805
355
Δ
50.5
3821
95.1
96.2
96.4
0.89
550
6.7
2.5
1■H1212-3BB73-2■■■
1000 rpm, 6-pole
240
322
315
Y
50.6
2294
93.9
95.1
95.4
0.82
245
6.6
2.1
1■H1212-3AC13-3■■■
295
396
315
Y
50.6
2819
94.2
95.3
95.6
0.83
295
6.7
2.1
1■H1212-3AC33-3■■■
340
456
315
Y
50.6
3250
94.3
95.4
95.7
0.84
335
6.5
2.0
1■H1212-3AC53-3■■■
1■H1212-3AC73-3■■■
385
516
315
Δ
50.6
3679
94.4
95.6
95.9
0.85
375
6.6
2.0
455
610
355
Δ
50.4
4348
94.5
95.5
95.7
0.86
440
7.6
2.3
1■H1212-3BC53-3■■■
520
697
355
Δ
50.4
4968
94.7
95.7
95.7
0.86
500
8.1
2.0
1■H1212-3BC73-3■■■
750 rpm, 6-pole
195
261
315
Y
38.1
2483
92.6
94.0
94.6
0.81
205
6.1
2.1
1■H1212-3AC13-4■■■
250
335
315
Y
38.1
3186
93.0
94.4
95.0
0.83
250
6.2
2.0
1■H1212-3AC33-4■■■
275
369
315
Δ
38.1
3505
93.0
94.4
95.0
0.84
275
5.9
1.9
1■H1212-3AC53-4■■■
310
416
315
Δ
38.1
3948
93.1
94.5
95.2
0.85
305
5.8
1.9
1■H1212-3AC73-4■■■
360
483
355
Y
37.9
4586
93.5
94.7
95.1
0.86
350
7.2
2.2
1■H1212-3BC53-4■■■
410
550
355
Δ
37.9
5223
93.6
94.8
95.2
0.87
395
7.3
1.9
1■H1212-3BC73-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V
3000 rpm, 4-pole
310
416
315
Δ
100.8 987
94.6
95.3
95.0
0.89
320
5.4
1.8
1■H1222-3AB13-1■■■
1■H1222-3AB33-1■■■
390
523
315
Δ
100.7 1242
95.1
95.7
95.5
0.90
395
5.9
1.9
445
597
315
Δ
100.6 1417
95.3
95.9
95.5
0.90
450
6.8
2.2
1■H1222-3AB53-1■■■
510
684
315
Δ
100.7 1624
95.4
96.0
95.8
0.91
510
6.6
2.2
1■H1222-3AB73-1■■■
540
724
355
Δ
100.6 1720
95.3
95.9
95.5
0.89
550
5.9
2.1
1■H1222-3BB53-1■■■
550
738
355
Δ
100.7 1751
95.2
95.9
95.6
0.89
560
5.4
1.9
1■H1222-3BB73-1■■■
1500 rpm, 4-pole
295
396
315
Δ
50.7
1879
94.1
95.2
95.6
0.88
310
6.1
2.2
1■H1222-3AB13-2■■■
370
496
315
Δ
50.6
2356
94.4
95.5
95.9
0.89
380
6.5
2.3
1■H1222-3AB33-2■■■
410
550
315
Δ
50.6
2611
94.6
95.6
95.9
0.90
415
7.1
2.5
1■H1222-3AB53-2■■■
490
657
315
Δ
50.6
3120
94.8
95.8
96.1
0.90
495
7.4
2.4
1■H1222-3AB73-2■■■
565
758
355
Δ
50.5
3598
95.3
96.2
96.4
0.88
580
7.3
2.8
1■H1222-3BB53-2■■■
585
784
355
Δ
50.5
3725
95.1
96.2
96.4
0.89
600
6.6
2.5
1■H1222-3BB73-2■■■
1000 rpm, 6-pole
240
322
315
Y
50.6
2294
93.9
95.0
95.4
0.82
270
6.5
2.1
1■H1222-3AC13-3■■■
290
389
315
Δ
50.5
2771
94.3
95.4
95.6
0.83
320
6.9
2.2
1■H1222-3AC33-3■■■
345
463
315
Δ
50.6
3297
94.3
95.5
95.8
0.84
375
6.5
2.0
1■H1222-3AC53-3■■■
1■H1222-3AC73-3■■■
380
510
315
Δ
50.5
3631
94.5
95.6
95.8
0.84
415
6.9
2.0
450
603
355
Δ
50.4
4301
94.5
95.5
95.7
0.86
480
7.5
2.3
1■H1222-3BC53-3■■■
510
684
355
Δ
50.4
4873
94.7
95.7
95.7
0.86
540
8.3
2.0
1■H1222-3BC73-3■■■
750 rpm, 6-pole
180
241
315
Y
38.1
2294
92.8
94.1
94.7
0.81
205
6.4
2.1
1■H1222-3AC13-4■■■
255
342
315
Δ
38.1
3250
93.1
94.5
95.0
0.82
290
6.3
2.1
1■H1222-3AC33-4■■■
280
375
315
Δ
38.1
3568
93.1
94.5
95.1
0.84
310
6.0
2.0
1■H1222-3AC53-4■■■
295
396
315
Δ
38.1
3760
93.1
94.5
95.1
0.85
320
6.0
2.0
1■H1222-3AC73-4■■■
365
489
355
Δ
37.9
4650
93.5
94.7
95.1
0.86
390
7.3
2.1
1■H1222-3BC53-4■■■
395
530
355
Δ
38
5031
93.5
94.7
95.1
0.87
420
7.1
2.0
1■H1222-3BC73-4■■■
For versions, see Article No. supplements and special versions
1■H1222-3AC73-4■■■
Prated
6/10
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.H1212-3AB13-1...
1.H1212-3AB33-1...
1.H1212-3AB53-1...
1.H1212-3AB73-1...
1.H1212-3BB53-1...
1.H1212-3BB73-1...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
320
400
452
560
560
560
1.H1212-3AB13-2...
1.H1212-3AB33-2...
1.H1212-3AB53-2...
1.H1212-3AB73-2...
1.H1212-3BB53-2...
1.H1212-3BB73-2...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
320
400
400
452
560
560
1.H1212-3AC13-3...
1.H1212-3AC33-3...
1.H1212-3AC53-3...
1.H1212-3AC73-3...
1.H1212-3BC53-3...
1.H1212-3BC73-3...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
250
320
400
400
452
560
1.H1212-3AC13-4...
1.H1212-3AC33-4...
1.H1212-3AC53-4...
1.H1212-3AC73-4...
1.H1212-3BC53-4...
1.H1212-3BC73-4...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
6SL3710-7LG32-2AA3
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
208
250
320
320
400
400
1.H1222-3AB13-1...
1.H1222-3AB33-1...
1.H1222-3AB53-1...
1.H1222-3AB73-1...
1.H1222-3BB53-1...
1.H1222-3BB73-1...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH35-8AA3
6SL3710-1GH35-8AA3
320
400
452
560
560
560
1.H1222-3AB13-2...
1.H1222-3AB33-2...
1.H1222-3AB53-2...
1.H1222-3AB73-2...
1.H1222-3BB53-2...
1.H1222-3BB73-2...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH37-4AA3
6SL3710-1GH37-4AA3
320
400
452
560
710
710
1.H1222-3AC13-3...
1.H1222-3AC33-3...
1.H1222-3AC53-3...
1.H1222-3AC73-3...
1.H1222-3BC53-3...
1.H1222-3BC73-3...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH35-8AA3
320
320
400
452
560
560
1.H1222-3AC13-4...
1.H1222-3AC33-4...
1.H1222-3AC53-4...
1.H1222-3AC73-4...
1.H1222-3BC53-4...
1.H1222-3BC73-4...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-1GH32-2AA3
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
208
320
320
320
400
452
Siemens D 81.8 · 04/2014
6
6/11
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LH1/1MH1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V
1500 rpm, 4-pole
210
282
315
Δ
50.4
1337
94.9
96.0
95.9
0.85
205
8.3
3.1
1■H1213-3AB13-2■■■
330
443
315
Δ
50.5
2101
95.0
96.0
96.2
0.87
310
7.9
2.9
1■H1213-3AB33-2■■■
385
516
315
Δ
50.5
2451
95.0
96.0
96.2
0.88
360
8.0
2.9
1■H1213-3AB53-2■■■
445
630
315
Δ
50.5
2992
95.0
96.0
96.2
0.89
435
7.8
2.5
1■H1213-3AB73-2■■■
570
764
355
Δ
50.5
3630
95.1
96.3
96.6
0.88
530
6.3
2.4
1■H1213-3BB53-2■■■
330
818
355
Δ
50.5
3885
95.3
96.3
96.6
0.89
560
6.6
2.5
1■H1213-3BB73-2■■■
1000 rpm, 6-pole
6
185
248
315
Y
50.4
1767
94.8
95.7
95.7
0.79
194
8.3
2.7
1■H1213-3AC13-3■■■
250
335
315
Y
50.5
2389
94.8
95.8
95.9
0.82
250
7.9
2.5
1■H1213-3AC33-3■■■
310
416
315
Y
50.5
2962
94.7
95.8
96.0
0.84
305
7.1
2.2
1■H1213-3AC53-3■■■
350
476
315
Δ
50.5
3392
94.7
95.8
96.1
0.84
350
7.0
2.2
1■H1213-3AC73-3■■■
465
624
355
Δ
50.5
4443
94.6
95.8
96.0
0.86
445
7.5
2.2
1■H1213-3BC53-3■■■
250
717
355
Δ
50.4
5112
94.9
95.9
96.1
0.86
510
7.9
1.9
1■H1213-3BC73-3■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V
1500 rpm, 4-pole
215
288
315
Δ
50.5
1369
94.9
96.0
95.9
0.85
230
8.1
3.0
1■H1223-3AB13-2■■■
310
416
315
Δ
50.5
1974
95.0
96.0
96.2
0.88
320
7.8
2.8
1■H1223-3AB33-2■■■
360
483
315
Δ
50.5
2292
95.0
96.0
96.1
0.89
370
8.0
2.9
1■H1223-3AB53-2■■■
445
597
315
Δ
50.5
2833
95.0
96.0
96.2
0.90
450
8.0
2.6
1■H1223-3AB73-2■■■
580
778
355
Δ
50.5
3693
95.4
96.4
96.6
0.87
600
7.1
2.7
1■H1223-3BB53-2■■■
600
805
355
Δ
50.5
3821
95.2
96.3
96.6
0.89
610
6.5
2.4
1■H1223-3BB73-2■■■
1000 rpm, 6-pole
175
235
315
Y
50.4
1672
94.9
95.7
95.7
0.79
200
8.8
2.8
1■H1223-3AC13-3■■■
255
342
315
Δ
50.5
2436
94.8
95.8
95.9
0.82
285
7.8
2.5
1■H1223-3AC33-3■■■
315
422
315
Δ
50.5
3010
94.7
95.8
96.1
0.84
340
7.2
2.2
1■H1223-3AC53-3■■■
360
483
315
Δ
50.5
3440
94.7
95.8
96.0
0.84
390
7.3
2.2
1■H1223-3AC73-3■■■
460
617
355
Δ
50.5
4395
94.6
95.8
96.1
0.86
490
7.3
2.3
1■H1223-3BC53-3■■■
525
704
355
Δ
50.4
5016
94.9
96.0
96.2
0.86
560
7.9
2.0
1■H1223-3BC73-3■■■
For versions, see Article No. supplements and special versions
6/12
Siemens D 81.8 · 04/2014
1■H1223-3AC73-3■■■
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.H1213-3AB13-2...
1240
1290
3.5
78
93
3000
1XB7 730
6SL3710-7LG32-6AA3
208
1.H1213-3AB33-2...
1420
1470
4.4
78
93
3000
1XB7 730
6SL3710-7LG33-3AA3
320
1.H1213-3AB53-2...
1600
1650
5.0
78
93
3000
1XB7 731
6SL3710-7LG34-1AA3
400
1.H1213-3AB73-2...
1770
1820
5.8
78
93
3000
1XB7 731
6SL3710-7LG34-7AA3
452
1.H1213-3BB53-2...
2200
2250
8.3
78
93.5
2600
1XB7 731
6SL3710-7LG32-6AA3
560
1.H1213-3BB73-2...
2320
2380
8.9
78
93.5
2600
1XB7 731
6SL3710-7LG33-3AA3
560
1.H1213-3AC13-3...
1270
1320
5.9
78
93
2600
1XB7 730
6SL3710-7LG32-2AA3
208
1.H1213-3AC33-3...
1450
1500
7.2
78
93
2600
1XB7 730
6SL3710-7LG32-6AA3
250
1.H1213-3AC53-3...
1630
1680
8.3
78
93
2600
1XB7 730
6SL3710-7LG33-3AA3
320
1.H1213-3AC73-3...
1740
1790
9.1
78
93
2600
1XB7 730
6SL3710-7LG34-1AA3
400
1.H1213-3BC53-3...
2190
2250
14.5
78
93.5
2500
1XB7 731
6SL3710-7LG32-2AA3
452
1.H1213-3BC73-3...
2340
2390
16.0
78
93.5
2500
1XB7 731
6SL3710-7LG32-6AA3
560
1.H1223-3AB13-2...
1240
1290
3.5
78
93
3000
1XB7 730
6SL3710-1GH32-6AA3
250
1.H1223-3AB33-2...
1420
1470
4.4
78
93
3000
1XB7 730
6SL3710-1GH33-3AA3
320
1.H1223-3AB53-2...
1600
1650
5.0
78
93
3000
1XB7 731
6SL3710-1GH34-1AA3
400
1.H1223-3AB73-2...
1770
1820
5.8
78
93
3000
1XB7 731
6SL3710-1GH34-7AA3
452
1.H1223-3BB53-2...
2200
2250
8.3
78
93.5
2600
1XB7 740
6SL3710-1GH37-4AA3
710
1.H1223-3BB73-2...
2320
2380
8.9
78
93.5
2600
1XB7 740
6SL3710-1GH37-4AA3
710
1.H1223-3AC13-3...
1270
1320
5.9
78
93
2600
1XB7 730
6SL3710-1GH32-6.A3
208
1.H1223-3AC33-3...
1450
1500
7.2
78
93
2600
1XB7 730
6SL3710-1GH33-3.A3
320
1.H1223-3AC53-3...
1630
1680
8.3
78
93
2600
1XB7 730
6SL3710-1GH34-1.A3
400
1.H1223-3AC73-3...
1740
1790
9.1
78
93
2600
1XB7 731
6SL3710-1GH34-1.A3
400
1.H1223-3BC53-3...
2190
2250
14.5
78
93.5
2500
1XB7 731
6SL3710-1GH32-6.A3
560
1.H1223-3BC73-3...
2340
2390
16.0
78
93.5
2500
1XB7 731
6SL3710-1GH33-3.A3
560
Siemens D 81.8 · 04/2014
6
6/13
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency
■ Selection and ordering data
6
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LH1/1MH1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V
3600 rpm, 4-pole
330
443
315
Δ
120.7 876
94.7
95.0
94.3
0.88
475
6.2
2.1
1■H1212-3AB15-5■■■
415
557
315
Δ
120.6 1101
95.2
95.5
94.9
0.90
580
7.3
2.4
1■H1212-3AB35-5■■■
435
583
315
Δ
120.7 1154
95.1
95.4
94.9
0.90
610
6.2
2.0
1■H1212-3AB55-5■■■
500
671
315
Δ
120.7 1327
95.3
95.7
95.2
0.91
690
6.7
2.2
1■H1212-3AB75-5■■■
3000 rpm, 4-pole
550
738
355
Δ
100.7 1752
95.2
95.9
95.6
0.89
780
5.0
1.8
1■H1212-3BB55-1■■■
1■H1212-3BB75-1■■■
620
831
355
Δ
100.6 1974
95.5
96.1
95.8
0.89
870
5.7
2.1
1800 rpm, 4-pole
365
489
315
Δ
60.7
1937
94.8
95.8
96.0
0.87
530
6.1
2.2
1■H1212-3AB15-6■■■
1■H1212-3AB35-6■■■
450
603
315
Δ
60.7
2388
95.0
96.0
96.2
0.89
630
6.3
2.2
1■H1212-3AB55-6■■■
495
664
315
Δ
60.7
2626
95.0
96.0
96.2
0.90
690
6.4
2.2
630
845
315
Δ
60.6
3343
95.5
96.4
96.5
0.90
870
7.7
2.2
1■H1212-3AB75-6■■■
665
892
355
Δ
60.5
3529
95.7
96.5
96.6
0.88
940
6.9
2.6
1■H1212-3BB55-6■■■
1■H1212-3BB75-6■■■
685
919
355
Δ
60.5
3635
95.5
96.5
96.6
0.89
960
6.3
2.3
1200 rpm, 6-pole
290
389
315
Δ
60.6
2308
94.5
95.6
95.9
0.82
445
6.1
1.9
1■H1212-3AC15-7■■■
355
476
315
Δ
60.6
2826
94.8
95.7
96.1
0.84
530
6.3
1.9
1■H1212-3AC35-7■■■
425
570
315
Δ
60.6
3385
95.1
96.1
96.2
0.84
630
6.8
2.0
1■H1212-3AC55-7■■■
1■H1212-3AC75-7■■■
455
610
315
Δ
60.6
3624
95.1
96.1
96.3
0.85
670
6.6
2.0
560
751
355
Δ
60.4
4459
95.2
96.1
96.1
0.86
820
7.9
2.2
1■H1212-3BC55-7■■■
1■H1212-3BC75-7■■■
610
818
355
Δ
60.4
4857
95.3
96.1
96.1
0.87
880
7.9
2.0
900 rpm, 6-pole
250
335
315
Δ
45.6
2653
93.7
94.9
95.4
0.81
390
6.0
2.0
1■H1212-3AC15-8■■■
1■H1212-3AC35-8■■■
315
422
315
Δ
45.6
3345
94.1
95.3
95.6
0.81
490
6.5
2.1
340
456
315
Δ
45.6
3608
94.0
95.2
95.6
0.84
510
5.9
1.9
1■H1212-3AC55-8■■■
1■H1212-3AC75-8■■■
380
510
315
Δ
45.6
4033
94.1
95.3
95.7
0.85
560
6.1
1.8
435
583
355
Δ
45.5
4617
94.1
95.3
95.6
0.87
630
6.8
2.1
1■H1212-3BC55-8■■■
485
650
355
Δ
45.5
5147
94.4
95.5
95.7
0.87
700
7.1
1.9
1■H1212-3BC75-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V
3600 rpm, 4-pole
340
456
315
Δ
120.6 902
94.8
95.0
94.3
0.88
530
6.5
2.2
1■H1222-3AB15-5■■■
405
543
315
Δ
120.7 1075
95.1
95.4
94.9
0.90
620
6.2
2.0
1■H1222-3AB35-5■■■
445
597
315
Δ
120.6 1181
95.2
95.5
94.9
0.90
680
7.0
2.3
1■H1222-3AB55-5■■■
1■H1222-3AB75-5■■■
510
684
315
Δ
120.5 1353
95.5
95.8
95.1
0.91
770
8.0
2.6
3000 rpm, 4-pole
560
751
355
Δ
100.6 1783
95.4
96.0
95.6
0.89
860
5.6
2.0
1■H1222-3BB55-1■■■
575
771
355
Δ
100.7 1831
95.3
96.0
95.7
0.89
880
5.2
1.8
1■H1222-3BB75-1■■■
1800 rpm, 4-pole
365
489
315
Δ
60.7
1937
94.8
95.7
96.0
0.87
580
6.1
2.2
1■H1222-3AB15-6■■■
455
610
315
Δ
60.6
2415
95.0
96.0
96.2
0.89
700
6.4
2.3
1■H1222-3AB35-6■■■
510
684
315
Δ
60.6
2706
95.1
96.1
96.3
0.90
770
6.7
2.3
1■H1222-3AB55-6■■■
590
791
315
Δ
60.6
3131
95.3
96.2
96.4
0.90
890
6.8
2.3
1■H1222-3AB75-6■■■
625
838
355
Δ
60.6
3317
95.4
96.4
96.6
0.89
960
6.1
2.3
1■H1222-3BB55-6■■■
710
952
355
Δ
60.5
3767
95.7
96.6
96.7
0.89
1080
7.0
2.6
1■H1222-3BB75-6■■■
1200 rpm, 6-pole
305
409
315
Δ
60.6
2429
94.8
95.7
96.0
0.81
520
6.6
2.1
1■H1222-3AC15-7■■■
360
483
315
Δ
60.6
2867
94.9
95.7
96.1
0.83
590
6.6
2.0
1■H1222-3AC35-7■■■
415
557
315
Δ
60.6
3305
95.0
96.0
96.2
0.84
680
6.5
2.0
1■H1222-3AC55-7■■■
465
624
315
Δ
60.6
3702
95.1
96.1
96.3
0.85
750
6.3
1.9
1■H1222-3AC75-7■■■
550
738
355
Δ
60.4
4379
95.2
96.1
96.1
0.86
870
8.0
2.3
1■H1222-3BC55-7■■■
1■H1222-3BC75-7■■■
605
811
355
Δ
60.4
4817
95.3
96.2
96.1
0.87
950
7.9
2.1
900 rpm, 6-pole
245
329
315
Δ
45.6
2601
93.8
94.9
95.3
0.80
425
6.4
2.1
1■H1222-3AC15-8■■■
305
409
315
Δ
45.6
3239
94.0
95.2
95.5
0.82
510
6.3
2.0
1■H1222-3AC35-8■■■
345
463
315
Δ
45.6
3664
94.0
95.2
95.6
0.84
570
6.0
1.9
1■H1222-3AC55-8■■■
375
503
315
Δ
45.6
3981
94.0
95.2
95.7
0.85
610
5.7
1.8
1■H1222-3AC75-8■■■
440
590
355
Δ
45.5
4669
94.3
95.4
95.6
0.86
700
7.1
2.1
1■H1222-3BC55-8■■■
500
671
355
Δ
45.4
5307
94.5
95.6
95.7
0.86
800
7.5
1.9
1■H1222-3BC75-8■■■
For versions, see Article No. supplements and special versions
1■H1222-3AC75-8■■■
Prated
6/14
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
LpfA,
LWA,
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
tolerance
+3 dB(A)
no-load
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.H1212-3AB15-5...
1.H1212-3AB35-5...
1.H1212-3AB55-5...
1.H1212-3AB75-5...
1240
1420
1600
1770
1290
1470
1650
1820
3.5
4.4
5.0
5.8
78
78
78
78
93
93
93
93
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
477
590
725
725
1.H1212-3BB55-1...
1.H1212-3BB75-1...
2200
2320
2250
2380
8.3
8.9
78
78
93.5
93.5
3300
3300
1XB7 740
1XB7 740
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
820
960
1.H1212-3AB15-6...
1.H1212-3AB35-6...
1.H1212-3AB55-6...
1.H1212-3AB75-6...
1.H1212-3BB55-6...
1.H1212-3BB75-6...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-0AA3
590
725
725
960
960
960
1.H1212-3AC15-7...
1.H1212-3AC35-7...
1.H1212-3AC55-7...
1.H1212-3AC75-7...
1.H1212-3BC55-7...
1.H1212-3BC75-7...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
477
590
725
725
820
960
1.H1212-3AC15-8...
1.H1212-3AC35-8...
1.H1212-3AC55-8...
1.H1212-3AC75-8...
1.H1212-3BC55-8...
1.H1212-3BC75-8...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
477
590
590
590
725
725
1.H1222-3AB15-5...
1.H1222-3AB35-5...
1.H1222-3AB55-5...
1.H1222-3AB75-5...
1240
1420
1600
1770
1290
1470
1650
1820
3.5
4.4
5.0
5.8
78
78
78
78
93
93
93
93
3600
3600
3600
3600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
590
725
725
820
1.H1222-3BB55-1...
1.H1222-3BB75-1...
2200
2320
2250
2380
8.3
8.9
78
78
93.5
93.5
3300
3300
1XB7 740
1XB7 740
6SL3710-1GE41-0AA3
6SL3710-1GE41-0AA3
960
960
1.H1222-3AB15-6...
1.H1222-3AB35-6...
1.H1222-3AB55-6...
1.H1222-3AB75-6...
1.H1222-3BB55-6...
1.H1222-3BB75-6...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
590
725
820
960
960
1092
1.H1222-3AC15-7...
1.H1222-3AC35-7...
1.H1222-3AC55-7...
1.H1222-3AC75-7...
1.H1222-3BC55-7...
1.H1222-3BC75-7...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-1GE41-0AA3
590
590
725
820
960
960
1.H1222-3AC15-8...
1.H1222-3AC35-8...
1.H1222-3AC55-8...
1.H1222-3AC75-8...
1.H1222-3BC55-8...
1.H1222-3BC75-8...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
477
590
590
725
725
820
Siemens D 81.8 · 04/2014
6
6/15
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LH1/1MH1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V
1800 rpm, 4-pole
300
402
315
Δ
60.5
1592
95.3
96.2
96.2
0.86
435
7.4
2.7
1■H1213-3AB15-6■■■
405
543
315
Δ
60.6
2149
95.3
96.2
96.4
0.89
570
7.0
2.5
1■H1213-3AB35-6■■■
460
617
315
Δ
60.6
2441
95.2
96.2
96.4
0.90
640
6.9
2.4
1■H1213-3AB55-6■■■
635
852
315
Δ
60.6
3370
95.5
96.4
96.6
0.90
880
7.6
2.2
1■H1213-3AB75-6■■■
690
925
355
Δ
60.5
3661
95.8
96.7
96.9
0.88
980
6.6
2.5
1■H1213-3BB55-6■■■
705
945
355
Δ
60.6
3741
95.6
96.6
96.9
0.89
990
6.1
2.3
1■H1213-3BB75-6■■■
1200 rpm, 6-pole
6
270
362
315
Δ
60.6
2151
94.7
95.8
96.0
0.82
415
6.5
2.0
1■H1213-3AC15-7■■■
360
483
315
Δ
60.6
2866
94.7
95.8
96.1
0.84
540
6.1
1.9
1■H1213-3AC35-7■■■
435
583
315
Δ
60.6
3464
95.1
96.1
96.3
0.84
650
6.5
2.0
1■H1213-3AC55-7■■■
460
617
315
Δ
60.6
3664
95.1
96.1
96.4
0.84
690
6.4
2.0
1■H1213-3AC75-7■■■
585
784
355
Δ
60.5
4658
95.4
96.4
96.5
0.85
860
7.5
2.1
1■H1213-3BC55-7■■■
635
852
355
Δ
60.5
5056
95.4
96.4
96.5
0.86
920
7.5
2.0
1■H1213-3BC75-7■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V
1800 rpm, 4-pole
295
396
315
Δ
60.5
1565
95.3
96.2
96.2
0.86
470
7.5
2.8
1■H1223-3AB15-6■■■
420
563
315
Δ
60.6
2229
95.2
96.2
96.4
0.89
640
7.0
2.4
1■H1223-3AB35-6■■■
495
664
315
Δ
60.6
2627
95.2
96.2
96.4
0.90
750
6.9
2.4
1■H1223-3AB55-6■■■
595
798
315
Δ
60.6
3157
95.3
96.2
96.5
0.91
890
6.8
2.3
1■H1223-3AB75-6■■■
640
858
355
Δ
60.6
3396
95.5
96.6
96.8
0.89
980
6.0
2.2
1■H1223-3BB55-6■■■
735
986
355
Δ
60.5
3900
95.8
96.8
96.9
0.89
1120
6.8
2.5
1■H1223-3BB75-6■■■
1200 rpm, 6-pole
310
416
315
Δ
60.6
2468
94.8
95.8
96.1
0.81
520
6.5
2.0
1■H1223-3AC15-7■■■
365
489
315
Δ
60.6
2907
94.9
95.9
96.2
0.83
600
6.4
2.0
1■H1223-3AC35-7■■■
420
563
315
Δ
60.6
3345
95.0
96.0
96.3
0.84
680
6.5
2.0
1■H1223-3AC55-7■■■
470
630
315
Δ
60.6
3742
95.1
96.1
96.4
0.85
750
6.3
1.9
1■H1223-3AC75-7■■■
575
771
355
Δ
60.5
4579
95.4
96.3
96.5
0.86
910
7.6
2.2
1■H1223-3BC55-7■■■
635
852
355
Δ
60.5
5056
95.5
96.4
96.6
0.86
1000
7.5
2.0
1■H1223-3BC75-7■■■
For versions, see Article No. supplements and special versions
6/16
Siemens D 81.8 · 04/2014
1■H1223-3AC75-7■■■
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.H1213-3AB15-6...
1240
1290
3.5
78
93
3000
1XB7 731
6SL3710-7LE35-0AA3
477
1.H1213-3AB35-6...
1420
1470
4.4
78
93
3000
1XB7 731
6SL3710-7LE36-1AA3
590
1.H1213-3AB55-6...
1600
1650
5.0
78
93
3000
1XB7 740
6SL3710-7LE37-5AA3
725
1.H1213-3AB75-6...
1770
1820
5.8
78
93
3000
1XB7 740
6SL3710-7LE41-0AA3
960
1.H1213-3BB55-6...
2200
2250
8.3
78
93.5
2600
1XB7 740
6SL3710-7LE41-2AA3
1230
1.H1213-3BB75-6...
2320
2380
8.9
78
93.5
2600
1XB7 740
6SL3710-7LE41-2AA3
1230
1.H1213-3AC15-7...
1270
1320
5.9
78
93
2600
1XB7 731
6SL3710-7LE35-0AA3
477
1.H1213-3AC35-7...
1450
1500
7.2
78
93
2600
1XB7 731
6SL3710-7LE36-1AA3
590
1.H1213-3AC55-7...
1630
1680
8.3
78
93
2600
1XB7 740
6SL3710-7LE37-5AA3
725
1.H1213-3AC75-7...
1740
1790
9.1
78
93
2600
1XB7 740
6SL3710-7LE37-5AA3
725
1.H1213-3BC55-7...
2190
2250
14.5
78
93.5
2500
1XB7 740
6SL3710-7LE41-0AA3
960
1.H1213-3BC75-7...
2340
2390
16.0
78
93.5
2500
1XB7 740
6SL3710-7LE41-0AA3
960
1.H1223-3AB15-6...
1240
1290
3.5
78
93
3000
1XB7 731
6SL3710-1GE35-0AA3
477
1.H1223-3AB35-6...
1420
1470
4.4
78
93
3000
1XB7 740
6SL3710-1GE37-5AA3
725
1.H1223-3AB55-6...
1600
1650
5.0
78
93
3000
1XB7 740
6SL3710-1GE38-4AA3
820
1.H1223-3AB75-6...
1770
1820
5.8
78
93
3000
1XB7 740
6SL3710-1GE41-0AA3
960
1.H1223-3BB55-6...
2200
2250
8.3
78
93.5
2600
1XB7 740
6SL3710-2GE41-1AA3
1092
1.H1223-3BB75-6...
2320
2380
8.9
78
93.5
2600
2 x 1XB7 740 6SL3710-2GE41-4AA3
1340
1.H1223-3AC15-7...
1270
1320
5.9
78
93
2600
1XB7 731
6SL3710-1GE36-1AA3
590
1.H1223-3AC35-7...
1450
1500
7.2
78
93
2600
1XB7 740
6SL3710-1GE37-5AA3
725
1.H1223-3AC55-7...
1630
1680
8.3
78
93
2600
1XB7 740
6SL3710-1GE37-5AA3
725
1.H1223-3AC75-7...
1740
1790
9.1
78
93
2600
1XB7 740
6SL3710-1GE38-4AA3
820
1.H1223-3BC55-7...
2190
2250
14.5
78
93.5
2500
1XB7 740
6SL3710-1GE41-0AA3
960
1.H1223-3BC75-7...
2340
2390
16.0
78
93.5
2500
1XB7 740
6SL3710-2GE41-1AA3
1092
Siemens D 81.8 · 04/2014
6
6/17
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency
■ Selection and ordering data
6
Operating values at rated output
Frame Confrated
Trated
ηrated, ηrated,
size
nection
5/4
4/4
1LH1/1MH1 cast-iron series
specially designed for
converter-fed operation
3/4
ted, 4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V
3600 rpm, 4-pole
315
422
315
Δ
120.7 836
94.4
94.8
94.1
0.88
355
5.9
2.0
1■H1212-3AB16-5■■■
400
536
315
Δ
120.6 1061
95.1
95.4
94.7
0.90
440
7.3
2.4
1■H1212-3AB36-5■■■
440
590
315
Δ
120.6 1167
95.1
95.4
94.7
0.90
485
7.7
2.5
1■H1212-3AB56-5■■■
505
677
315
Δ
120.5 1340
95.4
95.7
95.1
0.91
550
7.9
2.6
1■H1212-3AB76-5■■■
3000 rpm, 4-pole
530
711
355
Δ
100.7 1688
95.1
95.8
95.5
0.89
590
5.0
1.8
1■H1212-3BB56-1■■■
1■H1212-3BB76-1■■■
585
784
355
Δ
100.6 1863
95.3
95.9
95.7
0.89
650
5.5
2.0
1800 rpm, 4-pole
330
443
315
Δ
60.7
1752
94.5
95.6
95.8
0.88
370
6.2
2.2
1■H1212-3AB16-6■■■
1■H1212-3AB36-6■■■
440
590
315
Δ
60.6
2335
95.1
96.0
96.2
0.89
485
7.3
2.6
1■H1212-3AB56-6■■■
475
637
315
Δ
60.6
2521
95.1
96.0
96.2
0.90
520
7.3
2.5
580
778
315
Δ
60.5
3077
95.5
96.3
96.4
0.90
630
8.2
2.4
1■H1212-3AB76-6■■■
620
831
355
Δ
60.5
3290
95.6
96.5
96.5
0.88
690
7.2
2.7
1■H1212-3BB56-6■■■
1■H1212-3BB76-6■■■
680
912
355
Δ
60.4
3608
95.7
96.6
96.6
0.88
760
7.8
2.7
1200 rpm, 6-pole
275
369
315
Δ
60.6
2191
94.6
95.6
95.8
0.82
330
7.0
2.1
1■H1212-3AC16-7■■■
335
449
315
Δ
60.5
2668
94.9
95.7
96.0
0.83
400
7.1
2.2
1■H1212-3AC36-7■■■
380
510
315
Δ
60.6
3026
94.9
95.9
96.1
0.84
445
6.7
2.0
1■H1212-3AC56-7■■■
1■H1212-3AC76-7■■■
420
563
315
Δ
60.5
3345
95.0
96.0
96.1
0.85
485
7.0
2.1
525
704
355
Δ
60.4
4180
95.2
96.0
95.9
0.85
610
8.9
2.4
1■H1212-3BC56-7■■■
1■H1212-3BC76-7■■■
570
764
355
Δ
60.4
4538
95.2
96.1
96.0
0.86
650
8.7
2.2
900 rpm, 6-pole
225
302
315
Y
45.6
2390
93.5
94.7
95.1
0.81
280
6.3
2.1
1■H1212-3AC16-8■■■
1■H1212-3AC36-8■■■
295
396
315
Δ
45.5
3132
94.1
95.2
95.5
0.82
360
6.8
2.2
325
436
315
Δ
45.6
3451
94.0
95.2
95.6
0.84
385
6.4
2.0
1■H1212-3AC56-8■■■
1■H1212-3AC76-8■■■
360
483
315
Δ
45.5
3823
94.2
95.3
95.6
0.84
425
6.8
1.9
410
550
355
Δ
45.4
4353
94.3
95.3
95.5
0.86
475
7.7
2.3
1■H1212-3BC56-8■■■
455
610
355
Δ
45.4
4830
94.4
95.4
95.6
0.87
520
7.8
2.0
1■H1212-3BC76-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V
3600 rpm, 4-pole
315
422
315
Δ
120.6 836
94.6
94.8
94.1
0.89
390
7.2
2.4
1■H1222-3AB16-5■■■
385
516
315
Δ
120.5 1021
95.1
95.3
94.6
0.89
475
7.8
2.6
1■H1222-3AB36-5■■■
420
563
315
Δ
120.5 1114
95.1
95.3
94.6
0.90
510
8.6
2.8
1■H1222-3AB56-5■■■
1■H1222-3AB76-5■■■
465
624
315
Δ
120.6 1234
95.2
95.5
95.0
0.91
560
6.9
2.2
3000 rpm, 4-pole
520
697
355
Δ
100.7 1656
95.1
95.8
95.5
0.89
640
5.3
1.9
1■H1222-3BB56-1■■■
575
771
355
Δ
100.6 1831
95.4
96.0
95.6
0.89
710
5.9
2.1
1■H1222-3BB76-1■■■
1800 rpm, 4-pole
320
429
315
Δ
60.7
1699
94.5
95.5
95.8
0.88
400
5.9
2.1
1■H1222-3AB16-6■■■
425
570
315
Δ
60.6
2256
95.1
96.0
96.1
0.89
520
7.2
2.5
1■H1222-3AB36-6■■■
470
630
315
Δ
60.6
2494
95.1
96.0
96.2
0.90
570
7.2
2.5
1■H1222-3AB56-6■■■
580
778
315
Δ
60.5
3078
95.5
96.3
96.4
0.89
710
8.3
2.4
1■H1222-3AB76-6■■■
615
825
355
Δ
60.5
3263
95.6
96.5
96.5
0.88
760
7.5
2.8
1■H1222-3BB56-6■■■
635
852
355
Δ
60.5
3369
95.5
96.5
96.6
0.89
780
6.8
2.5
1■H1222-3BB76-6■■■
1200 rpm, 6-pole
260
349
315
Δ
60.6
2070
94.3
95.4
95.7
0.83
345
6.4
1.9
1■H1222-3AC16-7■■■
330
443
315
Δ
60.5
2628
94.9
95.7
96.0
0.83
435
7.1
2.2
1■H1222-3AC36-7■■■
375
503
315
Δ
60.6
2986
94.9
95.7
96.1
0.85
490
6.8
2.1
1■H1222-3AC56-7■■■
420
563
315
Δ
60.5
3344
95.1
96.0
96.2
0.84
550
7.0
2.2
1■H1222-3AC76-7■■■
505
677
355
Δ
60.4
4021
95.1
96.0
95.9
0.86
640
8.6
2.5
1■H1222-3BC56-7■■■
1■H1222-3BC76-7■■■
555
744
355
Δ
60.3
4418
95.4
96.1
95.9
0.85
710
9.6
2.2
900 rpm, 6-pole
225
302
315
Δ
45.5
2389
93.7
94.9
95.1
0.80
310
6.9
2.3
1■H1222-3AC16-8■■■
285
382
315
Δ
45.5
3026
94.0
95.1
95.4
0.80
395
7.0
2.3
1■H1222-3AC36-8■■■
325
436
315
Δ
45.5
3451
94.0
95.2
95.5
0.83
430
6.7
2.1
1■H1222-3AC56-8■■■
355
476
315
Δ
45.5
3770
94.2
95.3
95.6
0.84
465
6.8
2.0
1■H1222-3AC76-8■■■
405
543
355
Δ
45.4
4299
94.3
95.3
95.5
0.86
520
7.6
2.3
1■H1222-3BC56-8■■■
445
597
355
Δ
45.4
4723
94.4
95.4
95.6
0.87
560
8.0
2.1
1■H1222-3BC76-8■■■
For versions, see Article No. supplements and special versions
1■H1222-3AC76-8■■■
Prated
6/18
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕra- Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.H1212-3AB16-5...
1.H1212-3AB36-5...
1.H1212-3AB56-5...
1.H1212-3AB76-5...
1240
1420
1600
1770
1290
1470
1650
1820
3.5
4.4
5.0
5.8
78
78
78
78
93
93
93
93
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
400
452
560
560
1.H1212-3BB56-1...
1.H1212-3BB76-1...
2200
2320
2250
2380
8.3
8.9
78
78
93.5
93.5
3300
3300
1XB7 731
1XB7 740
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
710
710
1.H1212-3AB16-6...
1.H1212-3AB36-6...
1.H1212-3AB56-6...
1.H1212-3AB76-6...
1.H1212-3BB56-6...
1.H1212-3BB76-6...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
400
560
560
710
710
790
1.H1212-3AC16-7...
1.H1212-3AC36-7...
1.H1212-3AC56-7...
1.H1212-3AC76-7...
1.H1212-3BC56-7...
1.H1212-3BC76-7...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
400
400
452
560
710
710
1.H1212-3AC16-8...
1.H1212-3AC36-8...
1.H1212-3AC56-8...
1.H1212-3AC76-8...
1.H1212-3BC56-8...
1.H1212-3BC76-8...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
320
400
400
452
560
560
1.H1222-3AB16-5...
1.H1222-3AB36-5...
1.H1222-3AB56-5...
1.H1222-3AB76-5...
1240
1420
1600
1770
1290
1470
1650
1820
3.5
4.4
5.0
5.8
78
78
78
78
93
93
93
93
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GF34-1AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
400
560
560
560
1.H1222-3BB56-1...
1.H1222-3BB76-1...
2200
2320
2250
2380
8.3
8.9
78
78
93.5
93.5
3300
3300
1XB7 740
1XB7 740
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
710
710
1.H1222-3AB16-6...
1.H1222-3AB36-6...
1.H1222-3AB56-6...
1.H1222-3AB76-6...
1.H1222-3BB56-6...
1.H1222-3BB76-6...
1240
1420
1600
1770
2200
2320
1290
1470
1650
1820
2250
2380
3.5
4.4
5.0
5.8
8.3
8.9
78
78
78
78
78
78
93
93
93
93
93.5
93.5
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GF34-1AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
6SL3710-1GF38-1AA3
6SL3710-1GF38-1AA3
400
560
710
710
790
790
1.H1222-3AC16-7...
1.H1222-3AC36-7...
1.H1222-3AC56-7...
1.H1222-3AC76-7...
1.H1222-3BC56-7...
1.H1222-3BC76-7...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
400
452
560
560
710
710
1.H1222-3AC16-8...
1.H1222-3AC36-8...
1.H1222-3AC56-8...
1.H1222-3AC76-8...
1.H1222-3BC56-8...
1.H1222-3BC76-8...
1270
1450
1630
1740
2190
2340
1320
1500
1680
1790
2250
2390
5.9
7.2
8.3
9.1
14.5
16.0
78
78
78
78
78
78
93
93
93
93
93.5
93.5
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GF33-3AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
320
400
452
560
560
560
Siemens D 81.8 · 04/2014
6
6/19
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated
kW
Prated
hp
Frame Confrated
size
nection
Hz
FS
Trated
Nm
ηrated,
ηrated,
ηrated,
cosϕra- Irated
5/4
4/4
3/4
ted, 4/4
%
%
%
ILR/
Irated
TB/
Trated
A
1LH1/1MH1 cast-iron series
specially designed for
converter-fed operation
Article No.
L without explosion protection
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V
1800 rpm, 4-pole
255
342
315
Δ
60.5
1353
95.1
96.2
96.0
0.86
290
7.9
2.8
1■H1213-3AB16-6■■■
400
536
315
Δ
60.5
2122
95.3
96.2
96.3
0.88
445
7.9
2.8
1■H1213-3AB36-6■■■
445
597
315
Δ
60.5
2361
95.3
96.2
96.3
0.89
490
7.7
2.7
1■H1213-3AB56-6■■■
585
784
315
Δ
60.5
3104
95.4
96.3
96.5
0.89
650
7.8
2.4
1■H1213-3AB76-6■■■
640
858
355
Δ
60.5
3396
95.7
96.6
96.8
0.88
710
7.0
2.6
1■H1213-3BB56-6■■■
710
952
355
Δ
60.5
3767
95.9
96.8
96.9
0.88
790
7.5
2.6
1■H1213-3BB76-6■■■
1200 rpm, 6-pole
6
275
369
315
Δ
60.6
2190
94.7
95.8
96.0
0.82
330
7.0
2.1
1■H1213-3AC16-7■■■
335
449
315
Δ
60.5
2668
94.9
95.9
96.1
0.83
400
7.1
2.2
1■H1213-3AC36-7■■■
385
516
315
Δ
60.6
3066
94.8
95.9
96.2
0.84
450
6.6
2.0
1■H1213-3AC56-7■■■
425
570
315
Δ
60.6
3384
95.0
96.0
96.3
0.85
495
6.8
2.1
1■H1213-3AC76-7■■■
550
738
355
Δ
60.4
4378
95.4
96.3
96.4
0.84
640
8.5
2.3
1■H1213-3BC56-7■■■
595
798
355
Δ
60.4
4737
95.4
96.4
96.5
0.86
680
8.3
2.1
1■H1213-3BC76-7■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V
1800 rpm, 4-pole
230
308
315
Δ
60.5
1220
95.2
96.2
96.0
0.87
290
8.1
2.9
1■H1223-3AB16-6■■■
385
516
315
Δ
60.5
2043
95.4
96.2
96.3
0.88
475
7.9
2.8
1■H1223-3AB36-6■■■
435
583
315
Δ
60.5
2308
95.3
96.2
96.3
0.89
530
7.8
2.7
1■H1223-3AB56-6■■■
585
784
315
Δ
60.5
3104
95.5
96.3
96.5
0.89
720
8.1
2.4
1■H1223-3AB76-6■■■
640
858
355
Δ
60.5
3396
95.7
96.7
96.8
0.88
790
7.2
2.7
1■H1223-3BB56-6■■■
650
872
355
Δ
60.5
3449
95.6
96.6
96.8
0.89
790
6.7
2.5
1■H1223-3BB76-6■■■
1200 rpm, 6-pole
235
315
315
Δ
60.5
1872
94.7
95.8
96.0
0.82
315
7.0
2.2
1■H1223-3AC16-7■■■
340
456
315
Δ
60.5
2708
94.8
95.8
96.1
0.83
450
6.8
2.1
1■H1223-3AC36-7■■■
380
510
315
Δ
60.6
3026
94.9
95.9
96.2
0.84
495
6.7
2.0
1■H1223-3AC56-7■■■
430
577
315
Δ
60.5
3424
95.0
96.0
96.3
0.84
560
6.9
2.1
1■H1223-3AC76-7■■■
525
704
355
Δ
60.4
4180
95.3
96.3
96.4
0.85
670
8.2
2.4
1■H1223-3BC56-7■■■
585
784
355
Δ
60.4
4657
95.6
96.4
96.4
0.84
760
9.0
2.1
1■H1223-3BC76-7■■■
For versions, see Article No. supplements and special versions
6/20
Siemens D 81.8 · 04/2014
1■H1223-3AC76-7■■■
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
also possible
IL
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.H1213-3AB16-6...
1240
1290
3.5
78
93
3000
1XB7 730
6SL3710-7LG33-3AA3
320
1.H1213-3AB36-6...
1420
1470
4.4
78
93
3000
1XB7 731
6SL3710-7LG34-7AA3
452
1.H1213-3AB56-6...
1600
1650
5.0
78
93
3000
1XB7 731
6SL3710-7LG35-8AA3
560
1.H1213-3AB76-6...
1770
1820
5.8
78
93
3000
1XB7 740
6SL3710-7LG37-4AA3
710
1.H1213-3BB56-6...
2200
2250
8.3
78
93.5
2600
1XB7 740
6SL3710-7LG37-4AA3
710
1.H1213-3BB76-6...
2320
2380
8.9
78
93.5
2600
1XB7 740
6SL3710-7LG38-1AA3
790
1.H1213-3AC16-7...
1270
1320
5.9
78
93
2600
1XB7 730
6SL3710-7LG34-1AA3
400
1.H1213-3AC36-7...
1450
1500
7.2
78
93
2600
1XB7 731
6SL3710-7LG34-1AA3
400
1.H1213-3AC56-7...
1630
1680
8.3
78
93
2600
1XB7 731
6SL3710-7LG34-7AA3
452
1.H1213-3AC76-7...
1740
1790
9.1
78
93
2600
1XB7 731
6SL3710-7LG35-8AA3
560
1.H1213-3BC56-7...
2190
2250
14.5
78
93.5
2500
1XB7 740
6SL3710-7LG37-4AA3
710
1.H1213-3BC76-7...
2340
2390
16.0
78
93.5
2500
1XB7 740
6SL3710-7LG37-4AA3
710
1.H1223-3AB16-6...
1240
1290
3.5
78
93
3000
1XB7 730
6SL3710-1GF33-3AA3
320
1.H1223-3AB36-6...
1420
1470
4.4
78
93
3000
1XB7 731
6SL3710-1GF35-8AA3
560
1.H1223-3AB56-6...
1600
1650
5.0
78
93
3000
1XB7 731
6SL3710-1GF35-8AA3
560
1.H1223-3AB76-6...
1770
1820
5.8
78
93
3000
1XB7 740
6SL3710-1GF38-1AA3
790
1.H1223-3BB56-6...
2200
2250
8.3
78
93.5
2600
1XB7 740
6SL3710-1GF38-1AA3
790
1.H1223-3BB76-6...
2320
2380
8.9
78
93.5
2600
1XB7 740
6SL3710-1GF38-1AA3
790
1.H1223-3AC16-7...
1270
1320
5.9
78
93
2600
1XB7 730
6SL3710-1GF33-3AA3
320
1.H1223-3AC36-7...
1450
1500
7.2
78
93
2600
1XB7 731
6SL3710-1GF34-7AA3
452
1.H1223-3AC56-7...
1630
1680
8.3
78
93
2600
1XB7 731
6SL3710-1GF35-8AA3
560
1.H1223-3AC76-7...
1740
1790
9.1
78
93
2600
1XB7 731
6SL3710-1GF35-8AA3
560
1.H1223-3BC56-7...
2190
2250
14.5
78
93.5
2500
1XB7 740
6SL3710-1GF37-4AA3
710
1.H1223-3BC76-7...
2340
2390
16.0
78
93.5
2500
1XB7 740
6SL3710-1GF38-1AA3
790
Siemens D 81.8 · 04/2014
6
6/21
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for mains-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
■ Selection and ordering data
Operating values at rated output
Prated Prated Frame Con- frated
size
nection
kW
hp
Hz
FS
Trated
1LH1/1MH1 cast-iron series
specially designed for
mains-fed operation
Effiηrated, ηrated, ηrated, cosϕra- Irated
ciency 5/4
4/4
3/4
ted, 4/4
class
Nm
%
%
%
ILR/
Irated
TLR/ TB/
Trated Trated
Article No.
L without explosion protection
M with explosion protection
A
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
approx. 1500 rpm, 4-pole
6
265
355
315
Δ
50
1708
IE2
94.3
95.4
95.8
0.87
460
5.8
1.3
2.0
1■H1202-3AB11-2■■■
355
476
315
Δ
50
2286
IE2
94.8
95.8
96.1
0.88
610
6.5
1.5
2.2
1■H1202-3AB31-2■■■
425
570
315
Δ
50
2731
–
95.2
95.9
96.2
0.87
740
7.6
1.8
2.6
1■H1202-3AB51-2■■■
490
657
315
Δ
50
3149
–
95.3
95.9
96.3
0.88
840
7.8
1.9
2.7
1■H1202-3AB71-2■■■
510
684
355
Δ
50
3281
–
95.0
96.1
96.5
0.87
880
5.6
1.3
2.0
1■H1202-3BB51-2■■■
575
771
355
Δ
50
3696
–
95.3
96.3
96.6
0.88
980
6.2
1.5
2.2
1■H1202-3BB71-2■■■
approx. 1000 rpm, 6-pole
230
308
315
Δ
50
2222
IE2
94.2
95.3
95.6
0.82
425
6.7
1.4
2.3
1■H1202-3AC11-3■■■
285
382
315
Δ
50
2752
IE2
94.5
95.5
95.8
0.84
510
6.9
1.4
2.3
1■H1202-3AC31-3■■■
325
436
315
Δ
50
3138
IE2
94.6
95.6
95.9
0.85
580
6.7
1.3
2.2
1■H1202-3AC51-3■■■
395
530
315
Δ
50
3807
–
95.0
95.7
96.0
0.83
720
7.7
1.7
2.6
1■H1202-3AC71-3■■■
495
664
355
Δ
50
4770
–
94.7
95.8
96.0
0.84
890
7.1
1.6
2.0
1■H1202-3BC51-3■■■
530
711
355
Δ
50
5106
–
94.9
95.9
96.1
0.85
940
7.2
1.6
2.0
1■H1202-3BC71-3■■■
approx. 750 rpm, 8-pole
160
215
315
Δ
50
2057
–
93.7
94.8
94.8
0.75
325
5.8
1.2
2.0
1■H1202-3AD11-4■■■
235
315
315
Δ
50
3027
–
93.6
94.8
94.9
0.76
470
5.4
1.1
1.9
1■H1202-3AD31-4■■■
295
396
315
Δ
50
3804
–
93.4
94.8
95.0
0.77
580
5.2
1.1
1.8
1■H1202-3AD51-4■■■
325
436
315
Δ
50
4191
–
93.5
94.8
95.1
0.78
630
5.2
1.1
1.8
1■H1202-3AD71-4■■■
385
516
355
Δ
50
4978
–
93.0
94.2
94.8
0.81
730
4.5
0.9
1.4
1■H1202-3BD51-4■■■
420
563
355
Δ
50
5430
–
93.1
94.3
94.9
0.81
790
4.5
0.9
1.4
1■H1202-3BD71-4■■■
For versions, see Article No. supplements and special versions
6/22
Siemens D 81.8 · 04/2014
1■H1202-3AD71-4■■■
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for mains-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
Motor type
mIM B3
mIM V1
Blocking time
Admissible moment of inertia and
start-up times when starting up the
motor
cold
warm
3 × cold
tBr
tBr
Jadm
2 × warm
tst
Jadm
tst
J
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
tolerance
+3 dB(A)
no-load
Terminal
box
kgm2
s
kgm2
s
kgm2
dB(A)
dB(A)
Type
12.5
270
30.5
105
11.5
3.5
73
88
GT 640
9.5
340
24.0
130
9.0
4.4
73
88
1XB1 631
17.5
6.0
375
18.0
150
7.0
5.0
73
88
1XB1 631
15.5
5.0
425
17.0
175
7.0
5.8
73
88
1XB1 631
2250
28.5
7.5
620
37.5
260
15.5
8.3
73
88.5
1XB1 631
2320
2380
21.0
5.5
595
28.5
260
12.0
8.9
73
88.5
1XB1 631
1.H1202-3AC11-3...
1270
1320
26.5
9.5
460
23.0
185
9.0
5.9
68
83
GT 640
1.H1202-3AC31-3...
1450
1500
25.0
9.0
540
21.5
215
8.0
7.2
68
83
GT 640
1.H1202-3AC51-3...
1630
1680
26.5
9.5
640
23.0
255
9.0
8.3
68
83
1XB1 621
1.H1202-3AC71-3...
1740
1790
20.5
7.5
755
18.0
305
7.0
9.1
68
83
1XB1 631
1.H1202-3BC51-3...
2190
2250
20.5
7.0
670
18.0
305
8.0
14.5
68
83.5
1XB1 631
1.H1202-3BC71-3...
2340
2390
20.5
7.5
715
17.5
340
8.0
16.0
68
83.5
1XB1 631
1.H1202-3AD11-4...
1270
1320
40.5
23.5
1035
45.0
675
28.0
5.9
72
82
GT 640
1.H1202-3AD31-4...
1450
1500
35.0
16.0
1155
37.0
555
16.5
7.2
72
82
GT 640
1.H1202-3AD51-4...
1630
1680
33.5
12.5
1255
34.0
500
12.5
8.3
72
82
1XB1 621
1.H1202-3AD71-4...
1740
1790
34.0
12.5
1350
33.5
540
12.5
9.1
72
82
1XB1 631
1.H1202-3BD51-4...
2190
2250
37.5
13.5
1030
36.0
460
14.5
14.5
72
87.5
1XB1 631
1.H1202-3BD71-4...
2340
2390
38.0
14.0
1135
36.5
520
15.0
16.0
72
87.5
1XB1 631
kg
kg
s
s
1.H1202-3AB11-2...
1240
1290
36.0
1.H1202-3AB31-2...
1420
1470
26.5
1.H1202-3AB51-2...
1600
1650
1.H1202-3AB71-2...
1770
1820
1.H1202-3BB51-2...
2200
1.H1202-3BB71-2...
Siemens D 81.8 · 04/2014
6/23
6
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for mains-fed operation
Line voltage 400 V, 50 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated Prated Frame Con- frated
size
nection
kW
hp
Hz
FS
Trated
1LH1/1MH1 cast-iron series
specially designed for
mains-fed operation
Effiηrated, ηrated, ηrated, cosϕra- Irated
ciency 5/4
4/4
3/4
ted, 4/4
class
Nm
%
%
%
ILR/
Irated
TLR/ TB/
Trated Trated
Article No.
L without explosion protection
M with explosion protection
A
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
approx. 1500 rpm, 4-pole
285
382
315
Δ
50
1830
IE3
95.1
96.0
96.1
0.82
520
7.4
1.7
2.7
1■H1203-3AB11-2■■■
380
510
315
Δ
50
2443
–
95.2
96.1
96.3
0.86
660
7.4
1.7
2.6
1■H1203-3AB31-2■■■
430
577
315
Δ
50
2764
–
95.2
96.2
96.4
0.87
740
7.6
1.8
2.6
1■H1203-3AB51-2■■■
495
664
315
Δ
50
3181
–
95.4
96.3
96.5
0.88
840
7.8
1.9
2.6
1■H1203-3AB71-2■■■
555
744
355
Δ
50
3565
–
95.5
96.6
96.8
0.87
950
6.4
1.5
2.3
1■H1203-3BB71-2■■■
approx. 1000 rpm, 6-pole
6
225
302
315
Δ
50
2167
IE3
94.9
95.8
95.8
0.78
435
7.5
1.7
2.8
1■H1203-3AC11-3■■■
310
416
315
Δ
50
2987
IE3
94.9
95.9
96.0
0.80
580
7.7
1.7
2.7
1■H1203-3AC31-3■■■
355
476
315
Δ
50
3420
IE3
95.1
96.0
96.1
0.81
660
7.8
1.7
2.7
1■H1203-3AC51-3■■■
405
543
315
Δ
50
3905
–
95.1
96.1
96.2
0.83
730
7.6
1.6
2.6
1■H1203-3AC71-3■■■
475
637
355
Δ
50
4578
–
95.0
96.1
96.3
0.83
860
7.4
1.6
2.1
1■H1203-3BC51-3■■■
510
684
355
Δ
50
4911
–
95.1
96.2
96.4
0.84
910
7.5
1.6
2.1
1■H1203-3BC71-3■■■
For versions, see Article No. supplements and special versions
6/24
Siemens D 81.8 · 04/2014
1■H1203-3AC71-3■■■
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for mains-fed operation
Line voltage 400 V, 50 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
Blocking time
Admissible moment of inertia and
start-up times when starting up the
motor
cold
warm
3 × cold
tBr
tBr
Jadm
2 × warm
tst
Jadm
tst
J
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
tolerance
+3 dB(A)
no-load
Terminal
box
kg
kg
s
s
kgm2
s
kgm2
s
kgm2
dB(A)
dB(A)
Type
1.H1203-3AB11-2...
1240
1290
22.0
9.5
280
21.0
130
9.5
3.5
73
88
1XB1 621
1.H1203-3AB31-2...
1420
1470
19.0
7.0
310
18.0
130
7.5
4.4
73
88
1XB1 631
1.H1203-3AB51-2...
1600
1650
17.5
6.0
370
18.0
150
7.0
5.0
73
88
1XB1 631
1.H1203-3AB71-2...
1770
1820
15.5
5.5
395
16.0
170
6.5
5.8
73
88
1XB1 631
1.H1203-3BB71-2...
2320
2380
21.0
6.5
600
29.0
325
15.0
8.9
73
88.5
1XB1 631
1.H1203-3AC11-3...
1270
1320
21.5
10.0
495
19.5
255
9.5
5.9
68
83
GT 640
1.H1203-3AC31-3...
1450
1500
20.0
7.0
565
17.0
230
6.5
7.2
68
83
1XB1 621
1.H1203-3AC51-3...
1630
1680
19.0
7.0
605
16.0
255
6.5
8.3
68
83
1XB1 631
1.H1203-3AC71-3...
1740
1790
20.5
7.5
740
18.0
300
7.0
9.1
68
83
1XB1 631
1.H1203-3BC51-3...
2190
2250
20.5
9.0
690
18.5
380
10.0
14.5
68
83.5
1XB1 631
1.H1203-3BC71-3...
2340
2390
20.5
9.0
735
18.0
410
10.0
16.0
68
83.5
1XB1 631
Siemens D 81.8 · 04/2014
6/25
6
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for mains-fed operation
Line voltage 690 V, 50 Hz
High Efficiency
■ Selection and ordering data
Operating values at rated output
Prated Prated Frame Con- frated
size
nection
kW
hp
Hz
FS
Trated
1LH1/1MH1 cast-iron series
specially designed for
mains-fed operation
Effiηrated, ηrated, ηrated, cosϕra- Irated
ciency 5/4
4/4
3/4
ted, 4/4
class
Nm
%
%
%
ILR/
Irated
TLR/ TB/
Trated Trated
Article No.
L without explosion protection
M with explosion protection
A
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
approx. 1500 rpm, 4-pole
6
265
355
315
Y
50
1708
IE2
94.2
95.4
95.8
0.87
265
5.8
1.2
2.0
1■H1202-3AB14-2■■■
355
476
315
Y
50
2286
IE2
94.8
95.8
96.1
0.88
350
6.5
1.5
2.2
1■H1202-3AB34-2■■■
425
570
315
Y
50
2732
–
95.1
95.9
96.2
0.87
425
7.6
1.8
2.6
1■H1202-3AB54-2■■■
490
657
315
Y
50
3149
–
95.3
95.9
96.3
0.88
485
7.8
1.9
2.6
1■H1202-3AB74-2■■■
510
684
355
Y
50
3282
–
95.0
96.1
96.4
0.87
510
5.5
1.3
2.0
1■H1202-3BB54-2■■■
575
771
355
Y
50
3697
–
95.3
96.3
96.6
0.88
570
6.1
1.5
2.2
1■H1202-3BB74-2■■■
approx. 1000 rpm, 6-pole
230
308
315
Y
50
2222
IE2
94.2
95.3
95.6
0.82
245
6.7
1.4
2.3
1■H1202-3AC14-3■■■
285
382
315
Y
50
2752
IE2
94.4
95.5
95.8
0.84
295
6.8
1.4
2.3
1■H1202-3AC34-3■■■
325
436
315
Y
50
3139
IE2
94.5
95.6
95.9
0.85
335
6.6
1.3
2.2
1■H1202-3AC54-3■■■
395
530
315
Y
50
3807
–
95.0
95.7
96.0
0.83
415
7.7
1.6
2.6
1■H1202-3AC74-3■■■
490
657
355
Y
50
4722
–
94.7
95.8
96.0
0.84
510
7.1
1.6
2.0
1■H1202-3BC54-3■■■
530
711
355
Y
50
5107
–
94.8
95.9
96.1
0.85
540
7.2
1.6
2.0
1■H1202-3BC74-3■■■
approx. 750 rpm, 8-pole
160
215
315
Y
50
2058
–
93.7
94.8
94.9
0.75
188
5.8
1.2
2.0
1■H1202-3AD14-4■■■
235
315
315
Y
50
3027
–
93.5
94.8
94.9
0.76
275
5.3
1.1
1.9
1■H1202-3AD34-4■■■
295
396
315
Y
50
3805
–
93.4
94.8
95.0
0.77
340
5.1
1.1
1.8
1■H1202-3AD54-4■■■
325
436
315
Y
50
4192
–
93.5
94.8
95.1
0.78
370
5.1
1.1
1.8
1■H1202-3AD74-4■■■
385
516
355
Y
50
4979
–
92.9
94.2
94.8
0.81
420
4.4
0.9
1.4
1■H1202-3BD54-4■■■
420
563
355
Y
50
5431
–
93.1
94.3
94.9
0.81
460
4.4
0.9
1.4
1■H1202-3BD74-4■■■
For versions, see Article No. supplements and special versions
6/26
Siemens D 81.8 · 04/2014
1■H1202-3AD74-4■■■
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for mains-fed operation
Line voltage 690 V, 50 Hz
High Efficiency
Motor type
mIM B3
kg
mIM V1
kg
Blocking time
Admissible moment of inertia and
start-up times when starting up the
motor
cold
warm
3 × cold
tBr
tBr
Jadm
s
s
kgm2
2 × warm
tst
s
Jadm
kgm2
tst
s
J
kgm2
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
tolerance
+3 dB(A)
no-load
dB(A)
dB(A)
Terminal
box
Type
1.H1202-3AB14-2...
1240
1290
36.5
12.5
265
31.0
105
11.5
3.5
73
88
GT 640
1.H1202-3AB34-2...
1420
1470
27.0
9.5
340
24.5
130
9.0
4.4
73
88
1XB1 621
1.H1202-3AB54-2...
1600
1650
17.5
6.0
375
18.0
145
7.0
5.0
73
88
1XB1 621
1.H1202-3AB74-2...
1770
1820
15.5
5.5
425
17.0
175
7.0
5.8
73
88
1XB1 621
1.H1202-3BB54-2...
2200
2250
29.0
7.5
620
38.5
255
15.5
8.3
73
88.5
1XB1 621
1.H1202-3BB74-2...
2320
2380
21.5
5.5
600
29.0
255
12.0
8.9
73
88.5
1XB1 621
1.H1202-3AC14-3...
1270
1320
27.0
9.5
460
23.5
185
9.0
5.9
68
83
GT 640
1.H1202-3AC34-3...
1450
1500
25.5
9.0
540
22.0
210
8.0
7.2
68
83
GT 640
1.H1202-3AC54-3...
1630
1680
27.0
9.5
640
23.5
250
8.5
8.3
68
83
1XB1 621
1.H1202-3AC74-3...
1740
1790
20.5
7.5
755
18.5
300
7.0
9.1
68
83
1XB1 621
1.H1202-3BC54-3...
2190
2250
20.5
7.5
675
18.0
310
8.0
14.5
68
83.5
1XB1 621
1.H1202-3BC74-3...
2340
2390
20.5
7.5
715
18.0
330
8.0
16.0
68
83.5
1XB1 621
1.H1202-3AD14-4...
1270
1320
41.0
23.5
1030
45.5
675
28.0
5.9
72
82
GT 640
1.H1202-3AD34-4...
1450
1500
35.5
16.0
1150
37.0
550
16.5
7.2
72
82
GT 640
1.H1202-3AD54-4...
1630
1680
34.0
12.5
1250
34.0
495
12.5
8.3
72
82
1XB1 621
1.H1202-3AD74-4...
1740
1790
34.5
12.5
1345
34.0
535
12.5
9.1
72
82
1XB1 621
1.H1202-3BD54-4...
2190
2250
37.5
13.5
1020
36.0
450
14.0
14.5
72
87.5
1XB1 621
1.H1202-3BD74-4...
2340
2390
38.5
14.0
1125
37.0
510
15.0
16.0
72
87.5
1XB1 621
Siemens D 81.8 · 04/2014
6/27
6
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for mains-fed operation
Line voltage 690 V, 50 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated Prated Frame Con- frated
size
nection
kW
hp
Hz
FS
Trated
1LH1/1MH1 cast-iron series
specially designed for
mains-fed operation
Effiηrated, ηrated, ηrated, cosϕra- Irated
ciency 5/4
4/4
3/4
ted, 4/4
class
Nm
%
%
%
ILR/
Irated
TLR/ TB/
Trated Trated
Article No.
L without explosion protection
M with explosion protection
A
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
approx. 1500 rpm, 4-pole
285
382
315
Y
50
1831
IE3
95.1
96.0
96.1
0.82
305
7.2
1.7
2.7
1■H1203-3AB14-2■■■
380
510
315
Y
50
2443
–
95.1
96.1
96.3
0.86
385
7.3
1.7
2.6
1■H1203-3AB34-2■■■
430
577
315
Y
50
2764
–
95.2
96.2
96.3
0.87
430
7.5
1.8
2.6
1■H1203-3AB54-2■■■
495
664
315
Y
50
3182
–
95.3
96.3
96.5
0.88
490
7.7
1.9
2.6
1■H1203-3AB74-2■■■
555
744
355
Y
50
3565
–
95.5
96.6
96.8
0.87
550
6.4
1.5
2.2
1■H1203-3BB74-2■■■
approx. 1000 rpm, 6-pole
6
225
302
315
Y
50
2167
IE3
94.9
95.8
95.8
0.78
250
7.5
1.7
2.8
1■H1203-3AC14-3■■■
310
416
315
Y
50
2988
IE3
94.9
95.9
96.0
0.80
340
7.6
1.7
2.7
1■H1203-3AC34-3■■■
355
476
315
Y
50
3421
IE3
95.0
96.0
96.1
0.81
380
7.8
1.7
2.7
1■H1203-3AC54-3■■■
405
543
315
Y
50
3905
–
95.1
96.1
96.2
0.83
425
7.5
1.6
2.6
1■H1203-3AC74-3■■■
470
630
355
Y
50
4525
–
95.0
96.1
96.4
0.83
495
7.4
1.6
2.1
1■H1203-3BC54-3■■■
510
684
355
Y
50
4910
–
95.1
96.2
96.4
0.84
530
7.4
1.6
2.1
1■H1203-3BC74-3■■■
For versions, see Article No. supplements and special versions
6/28
Siemens D 81.8 · 04/2014
1■H1203-3AC74-3■■■
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for mains-fed operation
Line voltage 690 V, 50 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
Blocking time
Admissible moment of inertia and
start-up times when starting up the
motor
cold
warm
3 × cold
tBr
tBr
Jadm
2 × warm
tst
Jadm
tst
J
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
tolerance
+3 dB(A)
no-load
Terminal
box
kg
kg
s
s
kgm2
s
kgm2
s
kgm2
dB(A)
dB(A)
Type
1.H1203-3AB14-2...
1240
1290
22.5
9.5
280
21.5
130
9.5
3.5
73
88
GT 640
1.H1203-3AB34-2...
1420
1470
19.0
7.0
310
18.0
130
7.5
4.4
73
88
1XB1 621
1.H1203-3AB54-2...
1600
1650
17.5
6.0
370
18.0
150
7.0
5.0
73
88
1XB1 621
1.H1203-3AB74-2...
1770
1820
15.5
5.5
395
16.0
170
6.5
5.8
73
88
1XB1 621
1.H1203-3BB74-2...
2320
2380
21.5
6.5
605
29.5
325
15.5
8.9
73
88.5
1XB1 621
1.H1203-3AC14-3...
1270
1320
22.0
10.0
495
19.5
255
9.5
5.9
68
83
GT 640
1.H1203-3AC34-3...
1450
1500
20.0
7.0
565
17.0
230
6.5
7.2
68
83
1XB1 621
1.H1203-3AC54-3...
1630
1680
19.5
7.0
605
16.0
255
6.5
8.3
68
83
1XB1 621
1.H1203-3AC74-3...
1740
1790
21.0
7.5
740
18.5
295
7.0
9.1
68
83
1XB1 621
1.H1203-3BC54-3...
2190
2250
20.5
9.0
690
18.5
395
10.0
14.5
68
83.5
1XB1 621
1.H1203-3BC74-3...
2340
2390
20.5
9.0
735
18.5
405
10.0
16.0
68
83.5
1XB1 621
Siemens D 81.8 · 04/2014
6/29
6
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for mains-fed operation
Line voltage 460 V, 60 Hz
High Efficiency
■ Selection and ordering data
Operating values at rated output
Prated Prated Frame Con- frated
size
nection
kW
hp
Hz
FS
Trated
1LH1/1MH1 cast-iron series
specially designed for
mains-fed operation
Effiηrated, ηrated, ηrated, cosϕra- Irated
ciency 5/4
4/4
3/4
ted, 4/4
class
Nm
%
%
%
ILR/
Irated
TLR/ TB/
Trated Trated
Article No.
L without explosion protection
M with explosion protection
A
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
approx. 1800 rpm, 4-pole
6
300
402
315
Δ
60
1608
IE2
94.8
95.8
96.0
0.87
450
5.9
1.2
2.0
1■H1202-3AB15-6■■■
405
543
315
Δ
60
2169
–
95.2
96.1
96.3
0.88
600
6.5
1.4
2.2
1■H1202-3AB35-6■■■
485
650
315
Δ
60
2593
–
95.6
95.9
96.4
0.88
720
7.7
1.7
2.6
1■H1202-3AB55-6■■■
560
751
315
Δ
60
2994
–
95.7
95.9
96.6
0.89
820
7.9
1.8
2.6
1■H1202-3AB75-6■■■
565
758
355
Δ
60
3024
–
95.4
96.4
96.6
0.88
840
5.7
1.2
2.0
1■H1202-3BB55-6■■■
640
858
355
Δ
60
3423
–
95.7
96.6
96.7
0.88
940
6.3
1.4
2.2
1■H1202-3BB75-6■■■
approx. 1200 rpm, 6-pole
255
342
315
Δ
60
2049
IE2
94.8
95.7
95.9
0.83
405
6.9
1.3
2.2
1■H1202-3AC15-7■■■
310
416
315
Δ
60
2488
IE2
95.1
95.7
96.1
0.84
485
7.1
1.3
2.3
1■H1202-3AC35-7■■■
360
483
315
Δ
60
2890
IE2
95.1
95.7
96.2
0.86
550
6.9
1.2
2.2
1■H1202-3AC55-7■■■
440
590
315
Δ
60
3528
–
95.5
95.7
96.3
0.84
690
7.9
1.5
2.6
1■H1202-3AC75-7■■■
545
731
355
Δ
60
4369
–
95.2
96.2
96.3
0.85
840
7.4
1.5
2.0
1■H1202-3BC55-7■■■
585
784
355
Δ
60
4693
–
95.3
96.3
96.4
0.85
900
7.4
1.5
2.0
1■H1202-3BC75-7■■■
approx. 900 rpm, 8-pole
225
302
315
Δ
60
2418
–
93.4
94.7
95.1
0.77
385
4.7
0.9
1.6
1■H1202-3AD15-8■■■
285
382
315
Δ
60
3058
–
93.9
95.2
95.4
0.78
480
5.2
1.0
1.7
1■H1202-3AD35-8■■■
335
449
315
Δ
60
3592
–
94.2
95.3
95.5
0.78
570
5.2
1.0
1.7
1■H1202-3AD55-8■■■
370
496
315
Δ
60
3968
–
94.2
95.4
95.5
0.79
620
5.1
1.0
1.7
1■H1202-3AD75-8■■■
425
570
355
Δ
60
4568
–
93.8
94.9
95.3
0.81
690
4.6
0.9
1.4
1■H1202-3BD55-8■■■
470
630
355
Δ
60
5049
–
93.9
95.0
95.4
0.81
770
4.5
0.9
1.4
1■H1202-3BD75-8■■■
For versions, see Article No. supplements and special versions
6/30
Siemens D 81.8 · 04/2014
1■H1202-3AD75-8■■■
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for mains-fed operation
Line voltage 460 V, 60 Hz
High Efficiency
Motor type
mIM B3
mIM V1
Blocking time
Admissible moment of inertia and
start-up times when starting up the
motor
cold
warm
3 × cold
tBr
tBr
Jadm
2 × warm
tst
Jadm
tst
J
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
tolerance
+3 dB(A)
no-load
Terminal
box
kg
kg
s
s
kgm2
s
kgm2
s
kgm2
dB(A)
dB(A)
Type
1.H1202-3AB15-6...
1240
1290
33.0
13.0
200
32.0
80
12.0
3.5
73
88
GT 640
1.H1202-3AB35-6...
1420
1470
22.0
8.5
255
25.0
95
9.0
4.4
73
88
1XB1 621
1.H1202-3AB55-6...
1600
1650
13.5
5.5
280
18.5
110
7.0
5.0
73
88
1XB1 631
1.H1202-3AB75-6...
1770
1820
12.0
4.5
320
17.5
130
7.0
5.8
73
88
1XB1 631
1.H1202-3BB55-6...
2200
2250
24.0
6.5
380
32.0
175
14.0
8.3
73
88.5
1XB1 631
1.H1202-3BB75-6...
2320
2380
17.0
4.5
360
24.0
165
10.5
8.9
73
88.5
1XB1 631
1.H1202-3AC15-7...
1270
1320
28.0
10.0
345
24.5
140
9.0
5.9
68
83
GT 640
1.H1202-3AC35-7...
1450
1500
26.5
10.0
415
23.0
170
9.0
7.2
68
83
GT 640
1.H1202-3AC55-7...
1630
1680
28.0
10.0
485
24.5
190
9.0
8.3
68
83
1XB1 621
1.H1202-3AC75-7...
1740
1790
21.5
7.5
570
19.0
225
7.0
9.1
68
83
1XB1 631
1.H1202-3BC55-7...
2190
2250
21.5
7.5
510
18.5
230
8.0
14.5
68
83.5
1XB1 631
1.H1202-3BC75-7...
2340
2390
21.5
7.5
540
18.5
245
8.0
16.0
68
83.5
1XB1 631
1.H1202-3AD15-8...
1270
1320
43.0
15.0
635
42.5
245
14.5
5.9
72
82
GT 640
1.H1202-3AD35-8...
1450
1500
37.0
13.5
790
36.5
315
13.5
7.2
72
82
GT 640
1.H1202-3AD55-8...
1630
1680
35.5
13.0
915
35.0
360
12.5
8.3
72
82
1XB1 621
1.H1202-3AD75-8...
1740
1790
36.0
12.5
980
34.5
375
12.0
9.1
72
82
1XB1 631
1.H1202-3BD55-8...
2190
2250
39.5
14.5
750
37.5
340
15.0
14.5
72
87.5
1XB1 631
1.H1202-3BD75-8...
2340
2390
40.0
14.5
810
37.5
365
15.0
16.0
72
87.5
1XB1 631
Siemens D 81.8 · 04/2014
6/31
6
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for mains-fed operation
Line voltage 460 V, 60 Hz
Premium Efficiency
■ Selection and ordering data
Operating values at rated output
Prated Prated Frame Con- frated
size
nection
kW
hp
Hz
FS
Trated
1LH1/1MH1 cast-iron series
specially designed for
mains-fed operation
Effiηrated, ηrated, ηrated, cosϕra- Irated
ciency 5/4
4/4
3/4
ted, 4/4
class
Nm
%
%
%
ILR/
Irated
TLR/ TB/
Trated Trated
Article No.
L without explosion protection
M with explosion protection
A
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 130 (temperature class B)
approx. 1800 rpm, 4-pole
345
463
315
Δ
60
1845
IE3
95.3
96.2
96.3
0.84
540
6.9
1.4
2.5
1■H1203-3AB15-6■■■
435
583
315
Δ
60
2327
–
95.5
96.4
96.5
0.86
660
7.3
1.6
2.5
1■H1203-3AB35-6■■■
490
657
315
Δ
60
2620
–
95.6
96.5
96.6
0.87
730
7.6
1.7
2.5
1■H1203-3AB55-6■■■
565
758
315
Δ
60
3021
–
95.8
96.6
96.7
0.88
830
7.8
1.7
2.5
1■H1203-3AB75-6■■■
615
825
355
Δ
60
3287
–
95.9
96.8
97.0
0.87
920
6.5
1.4
2.2
1■H1203-3BB75-6■■■
approx. 1200 rpm, 6-pole
6
275
369
315
Δ
60
2207
IE3
95.1
96.0
96.1
0.80
450
7.6
1.5
2.5
1■H1203-3AC15-7■■■
345
463
315
Δ
60
2766
IE3
95.4
96.3
96.3
0.81
560
7.7
1.6
2.7
1■H1203-3AC35-7■■■
395
530
315
Δ
60
3167
–
95.5
96.4
96.4
0.82
630
7.9
1.6
2.7
1■H1203-3AC55-7■■■
450
603
315
Δ
60
3610
–
95.6
96.4
96.5
0.84
700
7.7
1.5
2.5
1■H1203-3AC75-7■■■
530
711
355
Δ
60
4251
–
95.5
96.5
96.6
0.84
820
7.6
1.5
2.0
1■H1203-3BC55-7■■■
565
758
355
Δ
60
4530
–
95.6
96.6
96.7
0.85
860
7.7
1.5
2.1
1■H1203-3BC75-7■■■
For versions, see Article No. supplements and special versions
6/32
Siemens D 81.8 · 04/2014
1■H1203-3AC75-7■■■
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
1LH1/1MH1 motors for mains-fed operation
Line voltage 460 V, 60 Hz
Premium Efficiency
Motor type
mIM B3
mIM V1
Blocking time
Admissible moment of inertia and
start-up times when starting up the
motor
cold
warm
3 × cold
tBr
tBr
Jadm
2 × warm
tst
Jadm
tst
J
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
tolerance
+3 dB(A)
no-load
Terminal
box
kg
kg
s
s
kgm2
s
kgm2
s
kgm2
dB(A)
dB(A)
Type
1.H1203-3AB15-6...
1240
1290
18.0
7.0
200
21.5
80
8.0
3.5
73
88
1XB1 621
1.H1203-3AB35-6...
1420
1470
15.0
6.0
235
18.5
95
7.0
4.4
73
88
1XB1 631
1.H1203-3AB55-6...
1600
1650
14.0
5.5
280
18.5
110
7.0
5.0
73
88
1XB1 631
1.H1203-3AB75-6...
1770
1820
12.0
4.5
295
16.5
125
6.5
5.8
73
88
1XB1 631
1.H1203-3BB75-6...
2320
2380
17.0
5.5
360
24.0
205
13.0
8.9
73
88.5
1XB1 631
1.H1203-3AC15-7...
1270
1320
23.0
8.0
350
19.5
140
7.5
5.9
68
83
GT 640
1.H1203-3AC35-7...
1450
1500
21.0
7.5
430
18.0
175
7.0
7.2
68
83
1XB1 621
1.H1203-3AC55-7...
1630
1680
20.0
7.0
455
16.5
190
6.5
8.3
68
83
1XB1 631
1.H1203-3AC75-7...
1740
1790
21.5
7.5
560
19.0
225
7.0
9.1
68
83
1XB1 631
1.H1203-3BC55-7...
2190
2250
21.5
9.0
520
19.0
285
10.0
14.5
68
83.5
1XB1 631
1.H1203-3BC75-7...
2340
2390
21.5
9.0
555
19.0
305
10.0
16.0
68
83.5
1XB1 631
Siemens D 81.8 · 04/2014
6/33
6
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
Dimensions
1LH1/1MH1 motors
■ Dimensional drawings
IM B3 type of construction
For terminal box dimensions, see Page 6/36.
L
LL
BE
HB'
HK
HC
GA
HD
AC
ØD
F
HB
AG
AD
BC
H
HA
EB
DB
G_D081_XX_00420
BA
E
6
C
B
BB
ØK
AA
Ø K'
A
AB
IM B35 and IM V1 types of construction
For flange dimensions, see Page 6/35 (Z = the number of retaining holes),
For terminal box dimensions, see Page 6/36
L
LL
HC
HB'
HK
HH
T
HD
AG
AD
BE
HB
ZxS
GA
AC
ØP
ØN
ØD
F
E
M
H
HA
EB
DB
G_D081_XX_00421
BA
LA
LE
Frame No. of
size
poles
Motor type
315
1.H12..-3A.1.-....
1.H12..-3A.3.-....
4, 6, 8
4, 6, 8
1.H12..-3A.5.-….
1.H12..-3A.7.-…..
Ø K'
B
BB
D
DB
560 120 680 630 630 180 780 180 315 28
AA
AB
AC
B
BA
BB
C
28 35 1280
85
M20 170 140 22 90
● 560 120 680 630 630 180 780 200 315 28
28 35 1300
95
M24 170 140 25 100
H
HA K
K'
L
E
EB
F
GA
560 120 680 630 835 180 985 180 315 28
28 35 1420
85
M20 170 140 22 90
● 560 120 680 630 835 180 985 200 315 28
28 35 1440
95
M24 170 140 25 100
630 150 780 710 800 220 980 200 355 35
35 42 1530
95
M24 170 140 25 100
● 630 150 780 710 800 220 980 224 355 28
28 35 1595
100 M24 210 180 28 106
● Bearing design for increased cantilever forces, for type of construction IM B3 only.
6/34
AA
A
AB
Dimension designation acc. to IEC
A
1.H12..-3A.5.-....
1.H12..-3A.7.-....
355
C
ØK
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
Dimensions
Flanges
G_D081_XX_00026
■ Dimensional drawings
(Z = the number of retaining holes)
Flange with through holes
Motor type
Frame size
No. of poles
Type of construction
Flange type
Dimension designation acc. to IEC
LA
1LH1/1MH1
315
355
4, 6
4, 6
IM B35, IM V1
IM B35, IM V1
LE
M
N
P
S
T
Z
Flange
29
170
740
680
800
22
6
8
Flange (optional)
22
170
600
550
660
22
6
8
Flange
29
170
840
780
900
22
6
8
Flange (optional)
22
170
600
550
660
22
6
8
Siemens D 81.8 · 04/2014
6/35
6
© Siemens AG 2014
Water-cooled motors with water-jacket cooling
Dimensions
Terminal boxes
■ Dimensional drawings
LL
BE
HB'
HK
HC
AG1
IM B3 type of construction
HD
HB
AG
AD
BC
G_D081_XX_00426
HC
HB'
AG1
LL
HH
HK
HD
AG
AD
BE
HB
6
IM B35 and IM V1 types of construction
G_D081_XX_00427
Motor
type
Frame
size
No. of
poles
Terminal box
Dimension designation acc. to IEC
AD
AG
AG1
BC
BE
HB
HB'
HH
HC
HD
HK
LL
1LH1/
1MH1
315
4, 6
1XB7 730
710
575
–
115
–
890
310
295
180
1025
255
345
1XB7 731
710
575
–
115
115
890
310
295
180
1025
255
345
1XB7 740
800
615
60
115
150
930
365
295
235
1110
340
425
GT640
655
555
–
115
110
870
225
295
155
970
170
310
1XB1 621
705
585
–
115
150
900
305
295
165
1020
250
330
1XB1 631
775
640
–
115
100
955
400
295
175
1090
320
555
1XB7 730
750
615
–
100
–
970
310
300
180
1105
255
345
1XB7 731
750
615
–
100
115
970
310
300
180
1105
255
345
1XB7 740
840
655
60
100
150
1010
365
300
235
1190
340
425
GT640
695
595
–
100
110
950
225
300
155
1050
170
310
1XB1 621
745
625
–
100
150
980
305
300
165
1100
250
330
1XB1 631
815
680
–
100
100
1035
400
300
175
1170
320
555
355
6/36
4, 6
Siemens D 81.8 · 04/2014
7
© Siemens AG 2014
Water-cooled motors with
air-to-water heat exchanger
7/2
7/2
7/4
7/6
7/8
7/10
7/12
7/12
7/13
7/14
1LN1/1MN1 motors for
converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
Line voltage 500 V, 50 Hz
High Efficiency
Line voltage 690 V, 50 Hz
High Efficiency
Line voltage 460 V, 60 Hz
High Efficiency
Line voltage 575 V, 60 Hz
High Efficiency
Dimensions
1LN1/1MN1 motors
Flanges
Terminal boxes
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Water-cooled motors with air-to-water heat exchanger
1LN1/1MN1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
■ Selection and ordering data
7
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
1LN1/1MN1 cast-iron series
specially designed for
converter-fed operation
3/4
4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V
3000 rpm, 4-pole
350
469
315
Δ
101.0
1114
94.8
95.8
95.9
0.88
560
4.5
1.5
1■N1212-3AB11-1■■■
1■N1212-3AB31-1■■■
440
590
315
Δ
100.9
1402
95.2
96.1
96.2
0.89
700
4.8
1.6
490
657
315
Δ
100.8
1561
95.4
96.2
96.2
0.90
770
5.2
1.7
1■N1212-3AB51-1■■■
570
764
315
Δ
100.8
1816
95.6
96.4
96.4
0.90
890
5.4
1.8
1■N1212-3AB71-1■■■
1■N1212-3BB51-1■■■
670
898
355
Δ
100.8
2133
95.5
96.4
96.4
0.88
1080
4.3
1.6
675
905
355
Δ
100.9
2149
95.3
96.4
96.4
0.88
1080
4.0
1.5
1■N1212-3BB71-1■■■
1500 rpm, 4-pole
315
422
315
Δ
50.7
2006
94.0
95.2
95.7
0.88
510
5.6
2.0
1■N1212-3AB11-2■■■
415
557
315
Δ
50.7
2643
94.5
95.7
96.1
0.89
660
6.3
2.2
1■N1212-3AB31-2■■■
455
610
315
Δ
50.6
2898
94.7
95.8
96.1
0.90
720
6.4
2.3
1■N1212-3AB51-2■■■
525
704
315
Δ
50.7
3343
94.7
95.8
96.2
0.90
830
6.3
2.2
1■N1212-3AB71-2■■■
630
845
355
Δ
50.7
4012
94.6
95.9
96.3
0.89
1000
5.1
1.9
1■N1212-3BB51-2■■■
715
959
355
Δ
50.6
4552
94.9
96.1
96.5
0.89
1140
5.5
2.1
1■N1212-3BB71-2■■■
1000 rpm, 6-pole
285
382
315
Δ
50.7
2722
93.7
95.0
95.5
0.82
495
5.7
1.8
1■N1212-3AC11-3■■■
345
463
315
Δ
50.7
3295
94.1
95.3
95.7
0.83
590
5.9
1.8
1■N1212-3AC31-3■■■
395
530
315
Δ
50.7
3773
94.1
95.4
95.8
0.84
670
5.7
1.8
1■N1212-3AC51-3■■■
1■N1212-3AC71-3■■■
445
597
315
Δ
50.6
4250
94.4
95.5
95.9
0.84
750
6.1
1.7
540
724
355
Δ
50.5
5158
94.3
95.5
95.8
0.86
890
6.4
1.9
1■N1212-3BC51-3■■■
615
825
355
Δ
50.5
5876
94.7
95.7
95.9
0.86
1020
7.1
1.7
1■N1212-3BC71-3■■■
750 rpm, 6-pole
230
308
315
Δ
38.2
2930
92.3
93.8
94.6
0.81
410
5.4
1.8
1■N1212-3AC11-4■■■
285
382
315
Δ
38.2
3629
92.7
94.2
94.9
0.83
495
5.4
1.8
1■N1212-3AC31-4■■■
320
429
315
Δ
38.2
4076
92.7
94.3
95.0
0.85
540
5.2
1.7
1■N1212-3AC51-4■■■
360
483
315
Δ
38.2
4586
92.8
94.4
95.1
0.85
610
5.2
1.6
1■N1212-3AC71-4■■■
420
563
355
Δ
38.1
5350
92.8
94.3
95.0
0.87
700
5.6
1.8
1■N1212-3BC51-4■■■
470
630
355
Δ
38.1
5986
93.1
94.6
95.1
0.88
770
5.9
1.7
1■N1212-3BC71-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V
3000 rpm, 4-pole
340
456
315
Δ
100.9
1082
94.9
95.8
95.9
0.88
610
4.5
1.5
1■N1222-3AB11-1■■■
1■N1222-3AB31-1■■■
440
590
315
Δ
100.9
1402
95.4
96.2
96.3
0.89
780
5.0
1.7
500
671
315
Δ
100.8
1592
95.6
96.3
96.3
0.90
880
5.5
1.8
1■N1222-3AB51-1■■■
510
684
315
Δ
100.9
1624
95.3
96.2
96.3
0.90
890
4.8
1.6
1■N1222-3AB71-1■■■
690
925
355
Δ
100.7
2198
95.7
96.5
96.5
0.89
1220
5.0
1.8
1■N1222-3BB51-1■■■
700
939
355
Δ
100.8
2230
95.6
96.5
96.5
0.89
1240
4.6
1.6
1■N1222-3BB71-1■■■
1500 rpm, 4-pole
330
443
315
Δ
50.7
2102
94.2
95.4
95.8
0.87
600
5.9
2.2
1■N1222-3AB11-2■■■
405
543
315
Δ
50.6
2579
94.5
95.7
96.1
0.89
720
6.3
2.3
1■N1222-3AB31-2■■■
460
617
315
Δ
50.6
2929
94.7
95.8
96.2
0.90
810
6.5
2.3
1■N1222-3AB51-2■■■
535
717
315
Δ
50.6
3407
94.8
95.9
96.3
0.90
940
6.5
2.2
1■N1222-3AB71-2■■■
645
865
355
Δ
50.7
4108
94.7
95.9
96.3
0.89
1140
5.2
2.0
1■N1222-3BB51-2■■■
750
1006
355
Δ
50.6
4776
95.1
96.2
96.5
0.89
1340
5.7
2.1
1■N1222-3BB71-2■■■
1000 rpm, 6-pole
280
375
315
Δ
50.7
2675
93.7
95.0
95.5
0.82
550
5.5
1.8
1■N1222-3AC11-3■■■
345
463
315
Δ
50.6
3295
94.1
95.3
95.7
0.83
660
6.0
1.9
1■N1222-3AC31-3■■■
400
536
315
Δ
50.6
3821
94.2
95.4
95.8
0.84
760
5.9
1.8
1■N1222-3AC51-3■■■
1■N1222-3AC71-3■■■
445
597
315
Δ
50.7
4251
94.3
95.5
95.9
0.85
830
5.8
1.7
550
738
355
Δ
50.5
5255
94.5
95.6
95.8
0.86
1020
6.9
1.9
1■N1222-3BC51-3■■■
595
798
355
Δ
50.5
5685
94.6
95.7
95.9
0.87
1080
7.1
1.7
1■N1222-3BC71-3■■■
750 rpm, 6-pole
235
315
315
Δ
38.2
2994
92.5
94.0
94.7
0.81
470
5.3
1.8
1■N1222-3AC11-4■■■
285
382
315
Δ
38.1
3632
92.9
94.3
95.0
0.82
560
5.7
1.9
1■N1222-3AC31-4■■■
325
436
315
Δ
38.2
4139
92.9
94.4
95.0
0.84
620
5.5
1.8
1■N1222-3AC51-4■■■
355
476
315
Δ
38.2
4522
92.8
94.4
95.1
0.85
670
5.2
1.6
1■N1222-3AC71-4■■■
420
563
355
Δ
38.1
5350
92.8
94.4
95.0
0.87
780
5.6
1.8
1■N1222-3BC51-4■■■
475
637
355
Δ
38.1
6050
93.1
94.6
95.1
0.88
870
6.0
1.6
1■N1222-3BC71-4■■■
For versions, see Article No. supplements and special versions
1■N1222-3AC76-8■■■
Prated
7/2
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕrated, Irated
ILR/
Irated
T B/
Trated
© Siemens AG 2014
Water-cooled motors with air-to-water heat exchanger
1LN1/1MN1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
LpfA,
LWA,
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
tolerance
+3 dB(A)
no-load
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.N1212-3AB11-1...
1.N1212-3AB31-1...
1.N1212-3AB51-1...
1.N1212-3AB71-1...
1.N1212-3BB51-1...
1.N1212-3BB71-1...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
6SL3710-7LE41-2AA3
590
725
820
960
1230
1230
1.N1212-3AB11-2...
1.N1212-3AB31-2...
1.N1212-3AB51-2...
1.N1212-3AB71-2...
1.N1212-3BB51-2...
1.N1212-3BB71-2...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
6SL3710-7LE41-2AA3
590
725
725
960
1230
1230
1.N1212-3AC11-3...
1.N1212-3AC31-3...
1.N1212-3AC51-3...
1.N1212-3AC71-3...
1.N1212-3BC51-3...
1.N1212-3BC71-3...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
590
590
725
820
960
1230
1.N1212-3AC11-4...
1.N1212-3AC31-4...
1.N1212-3AC51-4...
1.N1212-3AC71-4...
1.N1212-3BC51-4...
1.N1212-3BC71-4...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
477
590
590
725
725
820
1.N1222-3AB11-1...
1.N1222-3AB31-1...
1.N1222-3AB51-1...
1.N1222-3AB71-1...
1.N1222-3BB51-1...
1.N1222-3BB71-1...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3600
3600
3600
3600
3300
3300
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-4AA3
6SL3710-2GE41-4AA3
725
820
960
960
1340
1340
1.N1222-3AB11-2...
1.N1222-3AB31-2...
1.N1222-3AB51-2...
1.N1222-3AB71-2...
1.N1222-3BB51-2...
1.N1222-3BB71-2...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3000
3000
3000
3000
2600
2600
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-4AA3
6SL3710-2GE41-4AA3
725
725
820
960
1340
1340
1.N1222-3AC11-3...
1.N1222-3AC31-3...
1.N1222-3AC51-3...
1.N1222-3AC71-3...
1.N1222-3BC51-3...
1.N1222-3BC71-3...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-1AA3
590
725
820
960
1092
1092
1.N1222-3AC11-4...
1.N1222-3AC31-4...
1.N1222-3AC51-4...
1.N1222-3AC71-4...
1.N1222-3BC51-4...
1.N1222-3BC71-4...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
477
590
725
725
820
960
Siemens D 81.8 · 04/2014
7/3
7
© Siemens AG 2014
Water-cooled motors with air-to-water heat exchanger
1LN1/1MN1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency
■ Selection and ordering data
7
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
1LN1/1MN1 cast-iron series
specially designed for
converter-fed operation
3/4
4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V
3000 rpm, 4-pole
330
443
315
Δ
100.8
1051
94.9
95.8
95.8
0.88
435
4.9
1.7
1■N1212-3AB12-1■■■
1■N1212-3AB32-1■■■
440
590
315
Δ
100.7
1401
95.5
96.2
96.2
0.90
560
5.8
1.9
485
650
315
Δ
100.7
1544
95.5
96.3
96.2
0.90
620
6.0
2.0
1■N1212-3AB52-1■■■
500
671
315
Δ
100.9
1593
95.3
96.1
96.2
0.90
640
5.2
1.7
1■N1212-3AB72-1■■■
1■N1212-3BB52-1■■■
665
892
355
Δ
100.7
2118
95.5
96.4
96.4
0.89
860
4.9
1.7
680
912
355
Δ
100.8
2165
95.4
96.3
96.4
0.89
880
4.5
1.6
1■N1212-3BB72-1■■■
1500 rpm, 4-pole
295
396
315
Δ
50.7
1879
93.9
95.1
95.6
0.88
390
5.9
2.1
1■N1212-3AB12-2■■■
370
496
315
Δ
50.7
2357
94.3
95.5
95.9
0.89
485
6.2
2.2
1■N1212-3AB32-2■■■
435
583
315
Δ
50.6
2770
94.6
95.7
96.1
0.90
560
6.8
2.4
1■N1212-3AB52-2■■■
520
697
315
Δ
50.5
3311
95.0
96.0
96.2
0.89
680
7.5
2.2
1■N1212-3AB72-2■■■
660
885
355
Δ
50.6
4203
94.8
95.9
96.3
0.89
860
5.8
2.2
1■N1212-3BB52-2■■■
735
986
355
Δ
50.6
4680
95.0
96.1
96.4
0.89
950
6.2
2.1
1■N1212-3BB72-2■■■
1000 rpm, 6-pole
270
362
315
Δ
50.6
2579
93.8
95.0
95.4
0.82
385
6.0
1.9
1■N1212-3AC12-3■■■
320
429
315
Δ
50.6
3058
94.0
95.2
95.6
0.83
450
6.3
2.0
1■N1212-3AC32-3■■■
360
483
315
Δ
50.6
3439
94.0
95.2
95.7
0.84
500
5.9
1.9
1■N1212-3AC52-3■■■
1■N1212-3AC72-3■■■
400
536
315
Δ
50.6
3821
94.1
95.3
95.8
0.85
550
6.1
1.9
500
671
355
Δ
50.5
4779
94.3
95.4
95.7
0.86
680
7.0
2.1
1■N1212-3BC52-3■■■
565
758
355
Δ
50.5
5399
94.5
95.6
95.7
0.87
750
7.5
1.8
1■N1212-3BC72-3■■■
750 rpm, 6-pole
215
288
315
Δ
38.1
2740
92.3
93.8
94.5
0.81
315
5.8
2.0
1■N1212-3AC12-4■■■
260
349
315
Δ
38.1
3311
92.7
94.1
94.8
0.82
375
5.9
2.0
1■N1212-3AC32-4■■■
285
382
315
Δ
38.1
3630
92.6
94.1
94.9
0.84
400
5.5
1.8
1■N1212-3AC52-4■■■
320
429
315
Δ
38.1
4076
93.0
94.4
95.0
0.84
450
5.8
1.8
1■N1212-3AC72-4■■■
405
543
355
Δ
38
5158
93.1
94.5
95.0
0.87
550
6.6
1.9
1■N1212-3BC52-4■■■
420
563
355
Δ
38
5348
93.1
94.5
95.0
0.88
560
6.4
1.9
1■N1212-3BC72-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V
3000 rpm, 4-pole
360
483
315
Δ
100.9
1146
94.9
95.9
95.9
0.88
510
4.6
1.5
1■N1222-3AB12-1■■■
1■N1222-3AB32-1■■■
440
590
315
Δ
100.9
1402
95.2
96.1
96.2
0.89
620
4.8
1.6
490
657
315
Δ
100.9
1561
95.3
96.2
96.2
0.90
680
5.0
1.7
1■N1222-3AB52-1■■■
560
751
315
Δ
100.9
1784
95.5
96.3
96.4
0.90
780
5.1
1.7
1■N1222-3AB72-1■■■
650
872
355
Δ
100.9
2069
95.4
96.3
96.4
0.88
920
4.2
1.5
1■N1222-3BB52-1■■■
745
999
355
Δ
100.7
2373
95.7
96.6
96.5
0.89
1040
4.8
1.7
1■N1222-3BB72-1■■■
1500 rpm, 4-pole
315
422
315
Δ
50.8
2006
93.9
95.2
95.7
0.88
450
5.3
1.9
1■N1222-3AB12-2■■■
425
570
315
Δ
50.6
2707
94.6
95.7
96.1
0.88
610
6.3
2.3
1■N1222-3AB32-2■■■
470
630
315
Δ
50.6
2993
94.7
95.8
96.2
0.90
660
6.4
2.3
1■N1222-3AB52-2■■■
515
691
315
Δ
50.6
3280
94.8
95.9
96.2
0.90
720
6.5
2.3
1■N1222-3AB72-2■■■
705
945
355
Δ
50.6
4489
95.0
96.1
96.4
0.88
1000
5.8
2.2
1■N1222-3BB52-2■■■
715
959
355
Δ
50.6
4553
94.9
96.0
96.4
0.89
1000
5.4
2.1
1■N1222-3BB72-2■■■
1000 rpm, 6-pole
265
355
315
Δ
50.7
2531
93.7
95.0
95.5
0.82
410
5.5
1.8
1■N1222-3AC12-3■■■
350
469
315
Δ
50.6
3343
94.2
95.3
95.7
0.83
530
6.0
1.9
1■N1222-3AC32-3■■■
395
530
315
Δ
50.7
3773
94.1
95.4
95.8
0.84
590
5.8
1.8
1■N1222-3AC52-3■■■
1■N1222-3AC72-3■■■
445
597
315
Δ
50.6
4251
94.4
95.5
95.9
0.84
670
5.9
1.7
535
717
355
Δ
50.5
5111
94.2
95.4
95.7
0.87
780
6.3
1.9
1■N1222-3BC52-3■■■
605
811
355
Δ
50.5
5778
94.5
95.6
95.9
0.87
870
6.9
1.7
1■N1222-3BC72-3■■■
750 rpm, 6-pole
230
308
315
Δ
38.2
2931
92.2
93.8
94.6
0.81
365
5.2
1.8
1■N1222-3AC12-4■■■
285
382
315
Δ
38.2
3629
92.7
94.2
94.9
0.83
440
5.4
1.8
1■N1222-3AC32-4■■■
315
422
315
Δ
38.2
4013
92.5
94.1
94.9
0.85
475
5.1
1.7
1■N1222-3AC52-4■■■
345
463
315
Δ
38.2
4395
92.6
94.2
95.0
0.85
520
5.0
1.7
1■N1222-3AC72-4■■■
430
577
355
Δ
38.1
5477
93.0
94.4
95.0
0.87
630
5.8
1.8
1■N1222-3BC52-4■■■
475
637
355
Δ
38.1
6051
93.1
94.6
95.1
0.88
690
5.9
1.6
1■N1222-3BC72-4■■■
For versions, see Article No. supplements and special versions
1■N1222-3AC76-8■■■
Prated
7/4
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕrated, Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Water-cooled motors with air-to-water heat exchanger
1LN1/1MN1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.N1212-3AB12-1...
1.N1212-3AB32-1...
1.N1212-3AB52-1...
1.N1212-3AB72-1...
1.N1212-3BB52-1...
1.N1212-3BB72-1...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-8AA3
6SL3710-7LG38-8AA3
452
560
710
710
880
880
1.N1212-3AB12-2...
1.N1212-3AB32-2...
1.N1212-3AB52-2...
1.N1212-3AB72-2...
1.N1212-3BB52-2...
1.N1212-3BB72-2...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-8AA3
6SL3710-7LG41-0AA3
400
560
560
710
880
1000
1.N1212-3AC12-3...
1.N1212-3AC32-3...
1.N1212-3AC52-3...
1.N1212-3AC72-3...
1.N1212-3BC52-3...
1.N1212-3BC72-3...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
400
452
560
560
710
790
1.N1212-3AC12-4...
1.N1212-3AC32-4...
1.N1212-3AC52-4...
1.N1212-3AC72-4...
1.N1212-3BC52-4...
1.N1212-3BC72-4...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
320
400
400
452
560
560
1.N1222-3AB12-1...
1.N1222-3AB32-1...
1.N1222-3AB52-1...
1.N1222-3AB72-1...
1.N1222-3BB52-1...
1.N1222-3BB72-1...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
590
725
725
820
960
1092
1.N1222-3AB12-2...
1.N1222-3AB32-2...
1.N1222-3AB52-2...
1.N1222-3AB72-2...
1.N1222-3BB52-2...
1.N1222-3BB72-2...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-1AA3
477
725
725
725
1092
1092
1.N1222-3AC12-3...
1.N1222-3AC32-3...
1.N1222-3AC52-3...
1.N1222-3AC72-3...
1.N1222-3BC52-3...
1.N1222-3BC72-3...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
477
590
590
725
820
960
1.N1222-3AC12-4...
1.N1222-3AC32-4...
1.N1222-3AC52-4...
1.N1222-3AC72-4...
1.N1222-3BC52-4...
1.N1222-3BC72-4...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
370
477
477
590
725
725
Siemens D 81.8 · 04/2014
7
7/5
© Siemens AG 2014
Water-cooled motors with air-to-water heat exchanger
1LN1/1MN1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency
■ Selection and ordering data
7
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
1LN1/1MN1 cast-iron series
specially designed for
converter-fed operation
3/4
4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V
3000 rpm, 4-pole
330
443
315
Δ
100.9
1051
94.8
95.7
95.8
0.88
310
4.8
1.6
1■N1212-3AB13-1■■■
1■N1212-3AB33-1■■■
435
583
315
Δ
100.8
1385
95.3
96.1
96.2
0.90
400
5.5
1.8
495
664
315
Δ
100.7
1576
95.6
96.3
96.2
0.90
450
6.2
2.0
1■N1212-3AB53-1■■■
560
751
315
Δ
100.7
1783
95.6
96.4
96.3
0.91
500
6.0
1.9
1■N1212-3AB73-1■■■
1■N1212-3BB53-1■■■
675
905
355
Δ
100.8
2151
95.4
96.3
96.4
0.88
630
4.6
1.7
685
919
355
Δ
100.8
2181
95.3
96.3
96.4
0.88
640
4.2
1.5
1■N1212-3BB73-1■■■
1500 rpm, 4-pole
295
396
315
Δ
50.6
1879
94.0
95.2
95.7
0.88
280
6.1
2.2
1■N1212-3AB13-2■■■
385
516
315
Δ
50.6
2452
94.5
95.6
96.0
0.88
360
6.8
2.4
1■N1212-3AB33-2■■■
445
597
315
Δ
50.6
2834
94.7
95.8
96.1
0.89
415
7.0
2.5
1■N1212-3AB53-2■■■
505
677
315
Δ
50.6
3216
94.9
95.9
96.2
0.90
465
7.3
2.3
1■N1212-3AB73-2■■■
650
872
355
Δ
50.6
4139
94.7
95.9
96.3
0.89
600
5.5
2.1
1■N1212-3BB53-2■■■
705
945
355
Δ
50.6
4489
94.8
95.9
96.3
0.89
650
5.6
2.1
1■N1212-3BB73-2■■■
1000 rpm, 6-pole
245
329
315
Y
50.6
2341
93.9
95.0
95.4
0.82
250
6.4
2.0
1■N1212-3AC13-3■■■
320
429
315
Y
50.6
3056
93.9
95.1
95.6
0.83
320
6.2
1.9
1■N1212-3AC33-3■■■
365
489
315
Y
50.6
3487
94.0
95.2
95.7
0.84
360
6.0
1.9
1■N1212-3AC53-3■■■
1■N1212-3AC73-3■■■
410
550
315
Δ
50.6
3917
94.2
95.4
95.8
0.85
400
6.2
1.9
500
671
355
Δ
50.5
4778
94.2
95.3
95.6
0.86
480
6.9
2.1
1■N1212-3BC53-3■■■
570
764
355
Δ
50.5
5447
94.5
95.6
95.7
0.87
540
7.5
1.8
1■N1212-3BC73-3■■■
750 rpm, 6-pole
210
282
315
Y
38.1
2675
92.2
93.7
94.4
0.81
220
5.7
1.9
1■N1212-3AC13-4■■■
265
355
315
Y
38.1
3375
92.7
94.2
94.8
0.83
270
5.7
1.9
1■N1212-3AC33-4■■■
295
396
315
Δ
38.1
3757
92.6
94.1
94.9
0.84
295
5.5
1.8
1■N1212-3AC53-4■■■
325
436
315
Δ
38.1
4139
92.9
94.3
95.0
0.85
320
5.6
1.8
1■N1212-3AC73-4■■■
400
536
355
Y
38
5094
93.0
94.4
94.9
0.87
385
6.5
1.9
1■N1212-3BC53-4■■■
455
610
355
Δ
38
5795
93.2
94.6
95.1
0.87
435
6.6
1.7
1■N1212-3BC73-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V
3000 rpm, 4-pole
335
449
315
Δ
100.8
1067
94.9
95.8
95.8
0.88
350
4.9
1.7
1■N1222-3AB13-1■■■
1■N1222-3AB33-1■■■
420
563
315
Δ
100.8
1338
95.3
96.1
96.2
0.90
425
5.4
1.8
485
650
315
Δ
100.7
1544
95.6
96.3
96.2
0.90
490
6.2
2.1
1■N1222-3AB53-1■■■
550
738
315
Δ
100.7
1751
95.7
96.4
96.3
0.91
550
6.1
2.0
1■N1222-3AB73-1■■■
655
878
355
Δ
100.7
2087
95.5
96.4
96.4
0.89
670
4.8
1.7
1■N1222-3BB53-1■■■
670
898
355
Δ
100.8
2133
95.4
96.3
96.4
0.88
690
4.4
1.6
1■N1222-3BB73-1■■■
1500 rpm, 4-pole
300
402
315
Δ
50.7
1911
94.1
95.3
95.7
0.88
315
6.0
2.2
1■N1222-3AB13-2■■■
380
510
315
Δ
50.6
2420
94.4
95.5
95.9
0.89
390
6.4
2.3
1■N1222-3AB33-2■■■
425
570
315
Δ
50.6
2707
94.6
95.7
96.0
0.90
430
6.9
2.4
1■N1222-3AB53-2■■■
505
677
315
Δ
50.6
3216
94.8
95.9
96.2
0.90
510
7.2
2.3
1■N1222-3AB73-2■■■
675
905
355
Δ
50.6
4299
94.9
96.0
96.4
0.88
700
6.0
2.3
1■N1222-3BB53-2■■■
690
925
355
Δ
50.6
4393
94.8
95.9
96.4
0.89
710
5.6
2.1
1■N1222-3BB73-2■■■
1000 rpm, 6-pole
245
329
315
Y
50.6
2342
93.8
95.0
95.4
0.82
275
6.4
2.0
1■N1222-3AC13-3■■■
315
422
315
Δ
50.6
3010
94.0
95.2
95.6
0.83
350
6.3
2.0
1■N1222-3AC33-3■■■
365
489
315
Δ
50.6
3486
94.2
95.3
95.7
0.84
400
6.1
1.9
1■N1222-3AC53-3■■■
1■N1222-3AC73-3■■■
410
550
315
Δ
50.6
3918
94.3
95.4
95.8
0.84
450
6.4
1.9
490
657
355
Δ
50.5
4682
94.2
95.4
95.7
0.87
520
6.9
2.1
1■N1222-3BC53-3■■■
555
744
355
Δ
50.4
5303
94.5
95.6
95.8
0.87
580
7.7
1.9
1■N1222-3BC73-3■■■
750 rpm, 6-pole
205
275
315
Y
38.2
2610
92.1
93.7
94.4
0.82
235
5.6
1.9
1■N1222-3AC13-4■■■
270
362
315
Δ
38.1
3440
92.9
94.3
94.9
0.82
305
6.0
2.0
1■N1222-3AC33-4■■■
300
402
315
Δ
38.1
3821
92.7
94.2
94.9
0.84
330
5.7
1.8
1■N1222-3AC53-4■■■
320
429
315
Δ
38.1
4076
92.7
94.2
94.9
0.85
350
5.5
1.8
1■N1222-3AC73-4■■■
405
543
355
Δ
38
5157
93.1
94.5
95.0
0.87
430
6.6
1.9
1■N1222-3BC53-4■■■
435
583
355
Δ
38
5540
93.1
94.5
95.0
0.87
465
6.4
1.8
1■N1222-3BC73-4■■■
For versions, see Article No. supplements and special versions
1■N1222-3AC76-8■■■
Prated
7/6
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕrated, Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Water-cooled motors with air-to-water heat exchanger
1LN1/1MN1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.N1212-3AB13-1...
1.N1212-3AB33-1...
1.N1212-3AB53-1...
1.N1212-3AB73-1...
1.N1212-3BB53-1...
1.N1212-3BB73-1...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
320
400
452
560
710
710
1.N1212-3AB13-2...
1.N1212-3AB33-2...
1.N1212-3AB53-2...
1.N1212-3AB73-2...
1.N1212-3BB53-2...
1.N1212-3BB73-2...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
320
400
452
560
710
710
1.N1212-3AC13-3...
1.N1212-3AC33-3...
1.N1212-3AC53-3...
1.N1212-3AC73-3...
1.N1212-3BC53-3...
1.N1212-3BC73-3...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
250
320
400
400
560
560
1.N1212-3AC13-4...
1.N1212-3AC33-4...
1.N1212-3AC53-4...
1.N1212-3AC73-4...
1.N1212-3BC53-4...
1.N1212-3BC73-4...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
250
320
320
320
400
452
1.N1222-3AB13-1...
1.N1222-3AB33-1...
1.N1222-3AB53-1...
1.N1222-3AB73-1...
1.N1222-3BB53-1...
1.N1222-3BB73-1...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH35-8AA3
6SL3710-1GH37-4AA3
6SL3710-1GH37-4AA3
400
452
560
560
710
710
1.N1222-3AB13-2...
1.N1222-3AB33-2...
1.N1222-3AB53-2...
1.N1222-3AB73-2...
1.N1222-3BB53-2...
1.N1222-3BB73-2...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH37-4AA3
6SL3710-1GH37-4AA3
320
400
452
560
710
710
1.N1222-3AC13-3...
1.N1222-3AC33-3...
1.N1222-3AC53-3...
1.N1222-3AC73-3...
1.N1222-3BC53-3...
1.N1222-3BC73-3...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH37-4AA3
320
400
400
452
560
710
1.N1222-3AC13-4...
1.N1222-3AC33-4...
1.N1222-3AC53-4...
1.N1222-3AC73-4...
1.N1222-3BC53-4...
1.N1222-3BC73-4...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-1GH32-6AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
250
320
400
400
452
560
Siemens D 81.8 · 04/2014
7
7/7
© Siemens AG 2014
Water-cooled motors with air-to-water heat exchanger
1LN1/1MN1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency
■ Selection and ordering data
7
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
1LN1/1MN1 cast-iron series
specially designed for
converter-fed operation
3/4
4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V
3600 rpm, 4-pole
415
557
315
Δ
120.8
1102
95.3
95.9
95.8
0.88
590
5.0
1.7
1■N1212-3AB15-5■■■
525
704
315
Δ
120.8
1393
95.7
96.3
96.1
0.89
740
5.7
1.9
1■N1212-3AB35-5■■■
535
717
315
Δ
120.9
1420
95.4
96.1
96.0
0.89
750
5.0
1.6
1■N1212-3AB55-5■■■
620
831
315
Δ
120.8
1646
95.7
96.3
96.2
0.90
860
5.4
1.7
1■N1212-3AB75-5■■■
3000 rpm, 4-pole
655
878
355
Δ
100.9
2085
95.3
96.3
96.4
0.88
930
4.2
1.5
1■N1212-3BB55-1■■■
1■N1212-3BB75-1■■■
745
999
355
Δ
100.7
2373
95.7
96.6
96.5
0.89
1040
4.8
1.7
1800 rpm, 4-pole
370
496
315
Δ
60.7
1964
94.9
95.9
96.1
0.87
530
6.1
2.2
1■N1212-3AB15-6■■■
1■N1212-3AB35-6■■■
455
610
315
Δ
60.7
2415
95.0
96.0
96.3
0.89
640
6.2
2.2
1■N1212-3AB55-6■■■
500
671
315
Δ
60.7
2653
95.1
96.2
96.4
0.90
690
6.4
2.2
635
852
315
Δ
60.6
3369
95.6
96.5
96.7
0.90
880
7.7
2.2
1■N1212-3AB75-6■■■
785
1053
355
Δ
60.6
4166
95.4
96.5
96.7
0.89
1100
5.9
2.2
1■N1212-3BB55-6■■■
1■N1212-3BB75-6■■■
800
1073
355
Δ
60.7
4245
95.3
96.4
96.7
0.89
1120
5.4
2.0
1200 rpm, 6-pole
310
416
315
Δ
60.7
2468
94.3
95.5
95.9
0.82
475
5.7
1.7
1■N1212-3AC15-7■■■
375
503
315
Δ
60.7
2986
94.6
95.7
96.1
0.84
560
5.9
1.8
1■N1212-3AC35-7■■■
455
610
315
Δ
60.6
3622
95.0
96.0
96.2
0.84
680
6.3
1.9
1■N1212-3AC55-7■■■
1■N1212-3AC75-7■■■
485
650
315
Δ
60.6
3861
94.9
96.0
96.2
0.85
710
6.2
1.9
620
831
355
Δ
60.5
4935
95.1
96.0
96.1
0.86
900
7.2
2.0
1■N1212-3BC55-7■■■
1■N1212-3BC75-7■■■
670
898
355
Δ
60.5
5333
95.1
96.1
96.2
0.87
960
7.2
1.9
900 rpm, 6-pole
270
362
315
Δ
45.7
2865
93.4
94.7
95.3
0.82
420
5.6
1.8
1■N1212-3AC15-8■■■
1■N1212-3AC35-8■■■
340
456
315
Δ
45.6
3609
93.9
95.1
95.5
0.82
520
6.2
2.0
365
489
315
Δ
45.7
3875
93.7
95.0
95.5
0.85
540
5.6
1.8
1■N1212-3AC55-8■■■
1■N1212-3AC75-8■■■
400
536
315
Δ
45.6
4246
93.9
95.1
95.6
0.85
600
5.7
1.7
485
650
355
Δ
45.6
5148
93.7
95.1
95.5
0.87
710
6.0
1.9
1■N1212-3BC55-8■■■
545
731
355
Δ
45.5
5785
94.0
95.2
95.6
0.87
790
6.3
1.7
1■N1212-3BC75-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V
3600 rpm, 4-pole
425
570
315
Δ
120.8
1128
95.4
96.0
95.8
0.88
660
5.2
1.7
1■N1222-3AB15-5■■■
495
664
315
Δ
120.9
1314
95.5
96.2
96.1
0.89
760
5.0
1.7
1■N1222-3AB35-5■■■
560
751
315
Δ
120.8
1486
95.6
96.2
96.0
0.90
850
5.6
1.8
1■N1222-3AB55-5■■■
1■N1222-3AB75-5■■■
650
872
315
Δ
120.7
1725
95.9
96.5
96.2
0.91
970
6.3
2.0
3000 rpm, 4-pole
680
912
355
Δ
100.8
2166
95.6
96.5
96.5
0.88
1060
4.6
1.7
1■N1222-3BB55-1■■■
690
925
355
Δ
100.8
2197
95.5
96.4
96.5
0.88
1060
4.3
1.5
1■N1222-3BB75-1■■■
1800 rpm, 4-pole
365
489
315
Δ
60.7
1937
94.9
95.9
96.1
0.87
570
6.2
2.2
1■N1222-3AB15-6■■■
455
610
315
Δ
60.6
2415
95.1
96.1
96.3
0.89
700
6.4
2.3
1■N1222-3AB35-6■■■
515
691
315
Δ
60.6
2733
95.2
96.2
96.5
0.90
780
6.6
2.3
1■N1222-3AB55-6■■■
595
798
315
Δ
60.6
3157
95.4
96.3
96.6
0.91
890
6.8
2.3
1■N1222-3AB75-6■■■
710
952
355
Δ
60.6
3768
95.3
96.3
96.6
0.89
1080
5.4
2.0
1■N1222-3BB55-6■■■
840
1126
355
Δ
60.6
4458
95.5
96.5
96.8
0.89
1280
5.9
2.2
1■N1222-3BB75-6■■■
1200 rpm, 6-pole
330
443
315
Δ
60.6
2627
94.7
95.7
96.0
0.82
550
6.2
1.9
1■N1222-3AC15-7■■■
385
516
315
Δ
60.6
3065
94.8
95.8
96.1
0.83
640
6.1
1.9
1■N1222-3AC35-7■■■
440
590
315
Δ
60.6
3503
94.9
95.9
96.2
0.84
720
6.2
1.9
1■N1222-3AC55-7■■■
495
664
315
Δ
60.7
3941
94.9
96.0
96.3
0.85
800
5.9
1.8
1■N1222-3AC75-7■■■
605
811
355
Δ
60.5
4816
95.1
96.0
96.1
0.86
960
7.2
2.1
1■N1222-3BC55-7■■■
1■N1222-3BC75-7■■■
670
898
355
Δ
60.5
5332
95.1
96.1
96.2
0.87
1060
7.1
1.9
900 rpm, 6-pole
270
362
315
Δ
45.7
2867
93.4
94.7
95.2
0.81
460
5.9
1.9
1■N1222-3AC15-8■■■
325
436
315
Δ
45.6
3449
93.7
95.0
95.5
0.82
550
5.8
1.9
1■N1222-3AC35-8■■■
365
489
315
Δ
45.7
3874
93.7
95.0
95.6
0.84
600
5.7
1.8
1■N1222-3AC55-8■■■
400
536
315
Δ
45.7
4246
93.7
95.1
95.6
0.85
650
5.4
1.7
1■N1222-3AC75-8■■■
490
657
355
Δ
45.5
5200
93.9
95.2
95.5
0.87
780
6.4
1.9
1■N1222-3BC55-8■■■
560
751
355
Δ
45.5
5942
94.2
95.4
95.7
0.87
890
6.7
1.7
1■N1222-3BC75-8■■■
For versions, see Article No. supplements and special versions
1■N1222-3AC76-8■■■
Prated
7/8
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕrated, Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Water-cooled motors with air-to-water heat exchanger
1LN1/1MN1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
LpfA,
LWA,
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
tolerance
+3 dB(A)
no-load
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.N1212-3AB15-5...
1.N1212-3AB35-5...
1.N1212-3AB55-5...
1.N1212-3AB75-5...
1540
1730
1910
2070
1590
1780
1960
2120
3.3
4.2
4.8
5.7
79
79
79
79
95.5
95.5
95.5
95.5
3600
3600
3600
3600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE38-4AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
590
820
820
960
1.N1212-3BB55-1...
1.N1212-3BB75-1...
2740
2860
2790
2920
8.0
8.7
79
79
96
96
3300
3300
1XB7 740
1XB7 740
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
960
1230
1.N1212-3AB15-6...
1.N1212-3AB35-6...
1.N1212-3AB55-6...
1.N1212-3AB75-6...
1.N1212-3BB55-6...
1.N1212-3BB75-6...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
6SL3710-7LE41-2AA3
590
725
725
960
1230
1230
1.N1212-3AC15-7...
1.N1212-3AC35-7...
1.N1212-3AC55-7...
1.N1212-3AC75-7...
1.N1212-3BC55-7...
1.N1212-3BC75-7...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-0AA3
477
590
725
725
960
960
1.N1212-3AC15-8...
1.N1212-3AC35-8...
1.N1212-3AC55-8...
1.N1212-3AC75-8...
1.N1212-3BC55-8...
1.N1212-3BC75-8...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
477
590
590
725
725
820
1.N1222-3AB15-5...
1.N1222-3AB35-5...
1.N1222-3AB55-5...
1.N1222-3AB75-5...
1540
1730
1910
2070
1590
1780
1960
2120
3.3
4.2
4.8
5.7
79
79
79
79
95.5
95.5
95.5
95.5
3600
3600
3600
3600
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
725
820
960
1092
1.N1222-3BB55-1...
1.N1222-3BB75-1...
2740
2860
2790
2920
8.0
8.7
79
79
96
96
3300
3300
2 x 1XB7 740 6SL3710-2GE41-1AA3
2 x 1XB7 740 6SL3710-2GE41-1AA3
1092
1092
1.N1222-3AB15-6...
1.N1222-3AB35-6...
1.N1222-3AB55-6...
1.N1222-3AB75-6...
1.N1222-3BB55-6...
1.N1222-3BB75-6...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-4AA3
590
725
820
960
1092
1340
1.N1222-3AC15-7...
1.N1222-3AC35-7...
1.N1222-3AC55-7...
1.N1222-3AC75-7...
1.N1222-3BC55-7...
1.N1222-3BC75-7...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
590
725
725
820
960
1092
1.N1222-3AC15-8...
1.N1222-3AC35-8...
1.N1222-3AC55-8...
1.N1222-3AC75-8...
1.N1222-3BC55-8...
1.N1222-3BC75-8...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
477
590
725
725
820
960
Siemens D 81.8 · 04/2014
7
7/9
© Siemens AG 2014
Water-cooled motors with air-to-water heat exchanger
1LN1/1MN1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency
■ Selection and ordering data
7
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
1LN1/1MN1 cast-iron series
specially designed for
converter-fed operation
3/4
4/4
Article No.
L without explosion protection
kW
hp
FS
Hz
Nm
%
%
%
A
M with explosion protection
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V
3600 rpm, 4-pole
385
516
315
Δ
120.9
1022
95.0
95.7
95.6
0.88
435
4.8
1.6
1■N1212-3AB16-5■■■
505
677
315
Δ
120.7
1340
95.6
96.2
96.0
0.89
560
5.8
1.9
1■N1212-3AB36-5■■■
555
744
315
Δ
120.7
1473
95.6
96.2
95.9
0.90
610
6.1
2.0
1■N1212-3AB56-5■■■
635
852
315
Δ
120.7
1685
95.8
96.4
96.1
0.91
690
6.3
2.0
1■N1212-3AB76-5■■■
3000 rpm, 4-pole
630
845
355
Δ
100.8
2006
95.2
96.2
96.3
0.88
700
4.2
1.5
1■N1212-3BB56-1■■■
1■N1212-3BB76-1■■■
705
945
355
Δ
100.8
2246
95.4
96.4
96.4
0.89
780
4.5
1.6
1800 rpm, 4-pole
330
443
315
Δ
60.6
1752
94.6
95.7
96.0
0.88
370
6.2
2.2
1■N1212-3AB16-6■■■
1■N1212-3AB36-6■■■
440
590
315
Δ
60.6
2335
95.2
96.1
96.3
0.89
485
7.3
2.6
1■N1212-3AB56-6■■■
480
644
315
Δ
60.6
2547
95.2
96.2
96.4
0.90
520
7.3
2.5
590
791
315
Δ
60.5
3131
95.6
96.4
96.6
0.90
640
8.1
2.4
1■N1212-3AB76-6■■■
740
992
355
Δ
60.6
3927
95.3
96.4
96.6
0.89
820
6.0
2.3
1■N1212-3BB56-6■■■
1■N1212-3BB76-6■■■
820
1100
355
Δ
60.5
4351
95.5
96.5
96.7
0.89
900
6.6
2.3
1200 rpm, 6-pole
300
402
315
Δ
60.6
2388
94.4
95.5
95.8
0.82
365
6.3
1.9
1■N1212-3AC16-7■■■
360
483
315
Δ
60.6
2867
94.7
95.7
96.0
0.83
430
6.6
2.0
1■N1212-3AC36-7■■■
405
543
315
Δ
60.6
3225
94.7
95.8
96.1
0.84
475
6.3
1.9
1■N1212-3AC56-7■■■
1■N1212-3AC76-7■■■
445
597
315
Δ
60.6
3544
94.9
95.9
96.1
0.85
520
6.5
2.0
585
784
355
Δ
60.4
4658
95.1
96.0
96.0
0.86
670
8.1
2.1
1■N1212-3BC56-7■■■
1■N1212-3BC76-7■■■
630
845
355
Δ
60.4
5017
95.1
96.0
96.1
0.87
710
7.9
2.0
900 rpm, 6-pole
240
322
315
Y
45.6
2549
93.2
94.5
95.0
0.81
295
6.0
1.9
1■N1212-3AC16-8■■■
1■N1212-3AC36-8■■■
315
422
315
Δ
45.6
3345
93.9
95.0
95.4
0.82
385
6.4
2.1
345
463
315
Δ
45.6
3664
93.7
95.0
95.5
0.84
410
6.0
1.9
1■N1212-3AC56-8■■■
1■N1212-3AC76-8■■■
380
510
315
Δ
45.6
4035
94.0
95.2
95.6
0.84
450
6.5
1.8
465
624
355
Δ
45.5
4935
93.9
95.1
95.4
0.87
530
6.9
2.0
1■N1212-3BC56-8■■■
515
691
355
Δ
45.5
5466
94.0
95.2
95.5
0.87
590
6.8
1.8
1■N1212-3BC76-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V
3600 rpm, 4-pole
405
543
315
Δ
120.8
1075
95.3
95.9
95.7
0.88
500
5.6
1.8
1■N1222-3AB16-5■■■
495
664
315
Δ
120.7
1314
95.6
96.2
96.0
0.90
600
6.1
2.0
1■N1222-3AB36-5■■■
545
731
315
Δ
120.7
1446
95.7
96.2
95.9
0.90
660
6.6
2.2
1■N1222-3AB56-5■■■
1■N1222-3AB76-5■■■
580
778
315
Δ
120.8
1540
95.5
96.2
96.0
0.90
700
5.5
1.8
3000 rpm, 4-pole
620
831
355
Δ
100.8
1974
95.3
96.3
96.3
0.88
770
4.4
1.6
1■N1222-3BB56-1■■■
700
939
355
Δ
100.7
2230
95.6
96.4
96.4
0.89
860
4.9
1.7
1■N1222-3BB76-1■■■
1800 rpm, 4-pole
320
429
315
Δ
60.7
1699
94.6
95.6
96.0
0.88
400
5.9
2.1
1■N1222-3AB16-6■■■
430
577
315
Δ
60.6
2282
95.1
96.1
96.3
0.89
530
7.1
2.5
1■N1222-3AB36-6■■■
475
637
315
Δ
60.6
2521
95.2
96.2
96.4
0.90
580
7.1
2.5
1■N1222-3AB56-6■■■
585
784
315
Δ
60.5
3104
95.6
96.5
96.6
0.89
720
8.2
2.4
1■N1222-3AB76-6■■■
740
992
355
Δ
60.6
3927
95.4
96.4
96.6
0.89
910
6.2
2.3
1■N1222-3BB56-6■■■
755
1012
355
Δ
60.6
4007
95.3
96.3
96.6
0.89
920
5.7
2.1
1■N1222-3BB76-6■■■
1200 rpm, 6-pole
280
375
315
Δ
60.7
2229
94.1
95.3
95.7
0.83
370
6.0
1.8
1■N1222-3AC16-7■■■
355
476
315
Δ
60.6
2828
94.7
95.7
96.0
0.83
470
6.6
2.0
1■N1222-3AC36-7■■■
400
536
315
Δ
60.6
3185
94.7
95.8
96.1
0.84
520
6.4
1.9
1■N1222-3AC56-7■■■
450
603
315
Δ
60.6
3584
94.9
95.9
96.2
0.85
580
6.7
2.0
1■N1222-3AC76-7■■■
560
751
355
Δ
60.4
4459
95.0
95.9
96.0
0.86
710
7.8
2.2
1■N1222-3BC56-7■■■
1■N1222-3BC76-7■■■
625
838
355
Δ
60.4
4976
95.2
96.1
96.0
0.86
790
8.6
2.0
900 rpm, 6-pole
245
329
315
Δ
45.6
2602
93.4
94.6
95.1
0.80
340
6.3
2.1
1■N1222-3AC16-8■■■
305
409
315
Δ
45.5
3239
93.8
95.0
95.3
0.81
415
6.7
2.2
1■N1222-3AC36-8■■■
340
456
315
Δ
45.6
3610
93.8
95.1
95.5
0.83
450
6.4
2.0
1■N1222-3AC56-8■■■
380
510
315
Δ
45.6
4035
93.9
95.1
95.5
0.84
500
6.3
1.8
1■N1222-3AC76-8■■■
455
610
355
Δ
45.5
4828
93.9
95.1
95.5
0.87
580
6.8
2.1
1■N1222-3BC56-8■■■
505
677
355
Δ
45.5
5359
94.0
95.2
95.5
0.87
640
7.0
1.8
1■N1222-3BC76-8■■■
For versions, see Article No. supplements and special versions
1■N1222-3AC76-8■■■
Prated
7/10
Prated
Siemens D 81.8 · 04/2014
ηrated,
cosϕrated, Irated
ILR/
Irated
TB/
Trated
© Siemens AG 2014
Water-cooled motors with air-to-water heat exchanger
1LN1/1MN1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1.N1212-3AB16-5...
1.N1212-3AB36-5...
1.N1212-3AB56-5...
1.N1212-3AB76-5...
1540
1730
1910
2070
1590
1780
1960
2120
3.3
4.2
4.8
5.7
79
79
79
79
95.5
95.5
95.5
95.5
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
452
560
710
710
1.N1212-3BB56-1...
1.N1212-3BB76-1...
2740
2860
2790
2920
8.0
8.7
79
79
96
96
3300
3300
1XB7 740
1XB7 740
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
710
790
1.N1212-3AB16-6...
1.N1212-3AB36-6...
1.N1212-3AB56-6...
1.N1212-3AB76-6...
1.N1212-3BB56-6...
1.N1212-3BB76-6...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-8AA3
6SL3710-7LG41-0AA3
400
560
560
710
880
1000
1.N1212-3AC16-7...
1.N1212-3AC36-7...
1.N1212-3AC56-7...
1.N1212-3AC76-7...
1.N1212-3BC56-7...
1.N1212-3BC76-7...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
400
452
560
560
710
710
1.N1212-3AC16-8...
1.N1212-3AC36-8...
1.N1212-3AC56-8...
1.N1212-3AC76-8...
1.N1212-3BC56-8...
1.N1212-3BC76-8...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
320
400
452
452
560
710
1.N1222-3AB16-5...
1.N1222-3AB36-5...
1.N1222-3AB56-5...
1.N1222-3AB76-5...
1540
1730
1910
2070
1590
1780
1960
2120
3.3
4.2
4.8
5.7
79
79
79
79
95.5
95.5
95.5
95.5
3600
3600
3600
3600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
560
710
710
710
1.N1222-3BB56-1...
1.N1222-3BB76-1...
2740
2860
2790
2920
8.0
8.7
79
79
96
96
3300
3300
1XB7 740
1XB7 740
6SL3710-1GF38-1AA3
6SL3710-2GF41-1AA3
790
1036
1.N1222-3AB16-6...
1.N1222-3AB36-6...
1.N1222-3AB56-6...
1.N1222-3AB76-6...
1.N1222-3BB56-6...
1.N1222-3BB76-6...
1540
1730
1910
2070
2740
2860
1590
1780
1960
2120
2790
2920
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GF34-1AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF38-1AA3
6SL3710-2GF41-1AA3
6SL3710-2GF41-1AA3
400
560
710
790
1036
1036
1.N1222-3AC16-7...
1.N1222-3AC36-7...
1.N1222-3AC56-7...
1.N1222-3AC76-7...
1.N1222-3BC56-7...
1.N1222-3BC76-7...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GF34-1AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
6SL3710-1GF38-1AA3
400
560
560
710
710
790
1.N1222-3AC16-8...
1.N1222-3AC36-8...
1.N1222-3AC56-8...
1.N1222-3AC76-8...
1.N1222-3BC56-8...
1.N1222-3BC76-8...
1570
1750
1940
2050
2730
2880
1620
1800
1990
2100
2790
2930
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
95.5
95.5
95.5
95.5
96
96
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
400
452
452
560
710
710
Siemens D 81.8 · 04/2014
7
7/11
© Siemens AG 2014
Water-cooled motors with air-to-water heat exchanger
Dimensions
1LN1/1MN1 motors
■ Dimensional drawings
IM B3 type of construction
For terminal box dimensions, see Page 7/14.
L
AC
AD
AG
HK
HB'
BE
LL
HC
ØD
F
EB
BC
H
HA
GA
DB
G_D081_XX_00422
BA
E
B
BB
Ø K'
ØK
AA
A
AB
IM B35, IM V1 types of construction
For flange dimensions, see Page 7/13 (Z = the number of retaining holes),
For terminal box dimensions, see Page 7/14
L
HH
AD
AG
AC
T
HC
M
HB'
H
HA
EB
DB
G_D081_XX_00423
BA
LA
LE
Motor type
315
1.N12..-3A.1.-....
1.N12..-3A.3.-....
1.N12..-3A.5.-….
1.N12..-3A.7.-….
Ø K'
B
BB
AA
AB
AC
B
BA
BB
C
7/12
D
DB
35
1785
85
M20 170 140 22
90
● 560 120 680 1230 630 180 780 200 315 28
28
35
1805
95
M24 170 140 25
100
560 120 680 1230 835 180 985 180 315 28
28
35
1925
85
M20 170 140 22
90
● 560 120 680 1230 835 180 985 200 315 28
28
35
1945
95
M24 170 140 25
100
630 150 780 1470 800 220 980 200 355 35
35
42
2080
95
M24 170 140 22
100
● 630 150 780 1470 800 220 980 224 355 35
35
42
2145
100 M24 210 180 28
106
Siemens D 81.8 · 04/2014
HA K
L 1)
28
With IM V1 type of construction, dimension L may increase due to a
protective cover for the fan motor
H
K'
560 120 680 1230 630 180 780 180 315 28
● Bearing design for increased cantilever forces, for type of construction IM B3 only.
1)
AA
A
AB
Dimension designation acc. to IEC
A
1.N12..-3A.5.-....
1.N12..-3A.7.-....
4, 6
ØK
C
Frame No. of
size
poles
4, 6
BE
LL
ØP
ØN
ØD
GA
355
HK
ZxS
E
F
7
C
E
EB
F
GA
© Siemens AG 2014
Water-cooled motors with air-to-water heat exchanger
Dimensions
Flanges
G_D081_XX_00026
■ Dimensional drawings
(Z = the number of retaining holes)
Flange with through holes
Motor type
Frame size
No. of poles
Type of construction
Flange type
Dimension designation acc. to IEC
LA
1LN1/1MN1
315
355
4, 6
4, 6
IM B35, IM V1
IM B35, IM V1
LE
M
N
P
S
T
Z
8
Flange
29
170
740
680
800
22
6
Flange (optional)
22
170
600
550
660
22
6
8
Flange
29
170
840
780
900
22
6
8
Flange (optional)
22
170
600
550
660
22
6
8
7
Siemens D 81.8 · 04/2014
7/13
© Siemens AG 2014
Water-cooled motors with air-to-water heat exchanger
Dimensions
Terminal boxes
■ Dimensional drawings
IM B3 type of construction
BE
LL
HK
AG1
G_D081_XX_00429
BC
HC
AG
AD
HB'
IM B35, IM V1 types of construction
BE
LL
HK
AG1
7
HC
HB'
G_D081_XX_00430
AG
AD
HH
Motor
type
Frame
size
No. of
poles
Terminal box
Dimension designation acc. to IEC
AD
AG
AG1
BC
BE
HB'
HH
HC
HK
LL
1LN1/
1MN1
315
4, 6
1XB7 730
705
570
–
115
–
310
295
180
255
345
1XB7 731
705
570
–
115
115
310
295
180
255
345
1XB7 740
785
610
60
115
150
365
295
235
335
425
GT640
620
520
–
115
110
225
295
155
170
310
1XB1 621
700
580
–
115
150
305
295
165
250
330
1XB1 631
770
635
–
115
100
400
295
175
320
555
1XB7 730
750
615
–
100
–
310
300
180
255
345
1XB7 731
750
615
–
100
115
310
300
180
255
345
1XB7 740
830
655
60
100
150
365
300
235
335
425
GT640
665
565
–
100
110
225
300
155
170
310
1XB1 621
745
625
–
100
150
305
300
165
250
330
1XB1 631
815
680
–
100
100
400
300
175
320
555
355
7/14
4, 6
Siemens D 81.8 · 04/2014
8
© Siemens AG 2014
Self-ventilated motors –
open version
8/2
8/2
8/4
8/6
8/8
8/10
8/12
8/12
8/13
8/14
1LL1 motors for converter-fed
operation
Line voltage 400 V, 50 Hz
High Efficiency
Line voltage 500 V, 50 Hz
High Efficiency
Line voltage 690 V, 50 Hz
High Efficiency
Line voltage 460 V, 60 Hz
High Efficiency
Line voltage 575 V, 60 Hz
High Efficiency
Dimensions
1LL1 motors
Flanges
Terminal boxes
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Self-ventilated motors — open version
1LL1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
■ Selection and ordering data
Prated
8
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
TB/
Trated
1LL1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V
3000 rpm, 4-pole
330
443
315
Δ
100.9
1051
94.9
95.7
95.7
0.88
530
4.7
1.6
1LL1212-3AB11-1■■■
415
557
315
Δ
100.8
1322
95.3
96.1
96.0
0.89
660
5.1
1.7
1LL1212-3AB31-1■■■
1LL1212-3AB51-1■■■
470
630
315
Δ
100.8
1497
95.5
96.3
96.2
0.90
740
5.4
1.8
545
731
315
Δ
100.8
1736
95.7
96.4
96.4
0.91
840
5.8
1.9
1LL1212-3AB71-1■■■
670
898
355
Δ
100.8
2133
94.6
95.3
95.0
0.88
1080
4.3
1.6
1LL1212-3BB51-1■■■
1LL1212-3BB71-1■■■
675
905
355
Δ
100.9
2149
94.5
95.2
95.0
0.88
1100
4.0
1.5
1500 rpm, 4-pole
290
389
315
Δ
50.7
1847
94.0
95.1
95.3
0.88
470
6.0
2.2
1LL1212-3AB11-2■■■
1LL1212-3AB31-2■■■
420
563
315
Δ
50.7
2675
94.3
95.3
95.6
0.89
670
6.2
2.2
455
610
315
Δ
50.6
2898
94.4
95.5
95.8
0.90
720
6.4
2.3
1LL1212-3AB51-2■■■
530
711
315
Δ
50.7
3375
94.5
95.6
95.9
0.90
840
6.2
2.2
1LL1212-3AB71-2■■■
645
865
355
Δ
50.7
4108
94.3
95.5
95.9
0.89
1040
4.9
1.9
1LL1212-3BB51-2■■■
735
986
355
Δ
50.6
4680
94.6
95.8
96.1
0.89
1180
5.3
2.0
1LL1212-3BB71-2■■■
1000 rpm, 6-pole
265
355
315
Δ
50.6
2531
93.9
95.0
95.3
0.82
460
6.2
1.9
1LL1212-3AC11-3■■■
1LL1212-3AC31-3■■■
330
443
315
Δ
50.6
3152
94.1
95.2
95.6
0.83
570
6.1
1.9
380
510
315
Δ
50.6
3630
94.2
95.3
95.7
0.84
640
6.0
1.9
1LL1212-3AC51-3■■■
425
570
315
Δ
50.6
4061
94.5
95.5
95.8
0.84
720
6.4
1.8
1LL1212-3AC71-3■■■
1LL1212-3BC51-3■■■
520
697
355
Δ
50.5
4967
94.3
95.4
95.6
0.86
860
6.7
2.0
595
798
355
Δ
50.5
5685
94.6
95.6
95.7
0.86
980
7.4
1.7
1LL1212-3BC71-3■■■
750 rpm, 6-pole
205
275
315
Δ
38.1
2611
92.8
94.1
94.6
0.81
365
6.1
2.0
1LL1212-3AC11-4■■■
255
342
315
Δ
38.1
3249
93.2
94.5
95.0
0.82
445
6.1
2.0
1LL1212-3AC31-4■■■
290
389
315
Δ
38.1
3693
93.2
94.5
95.1
0.84
495
5.7
1.9
1LL1212-3AC51-4■■■
325
436
315
Δ
38.1
4139
93.3
94.7
95.2
0.85
550
5.7
1.8
1LL1212-3AC71-4■■■
375
503
355
Δ
38
4776
93.3
94.6
95.0
0.87
620
6.3
2.1
1LL1212-3BC51-4■■■
425
570
355
Δ
38
5412
93.5
94.7
95.2
0.87
700
6.4
1.8
1LL1212-3BC71-4■■■
• Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G120P, SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V
3000 rpm, 4-pole
320
429
315
Δ
100.9
1020
94.9
95.7
95.6
0.88
580
4.7
1.6
1LL1222-3AB11-1■■■
1LL1222-3AB31-1■■■
410
550
315
Δ
100.8
1306
95.4
96.1
96.1
0.90
720
5.4
1.8
475
637
315
Δ
100.7
1513
95.6
96.3
96.3
0.90
830
5.9
1.9
1LL1222-3AB51-1■■■
490
657
315
Δ
100.9
1561
95.4
96.2
96.3
0.90
860
5.0
1.7
1LL1222-3AB71-1■■■
1LL1222-3BB51-1■■■
690
925
355
Δ
100.7
2198
94.9
95.5
95.1
0.89
1240
4.9
1.8
700
939
355
Δ
100.8
2230
94.8
95.4
95.1
0.89
1260
4.5
1.6
1LL1222-3BB71-1■■■
1500 rpm, 4-pole
320
429
315
Δ
50.7
2038
94.0
95.1
95.3
0.87
590
6.0
2.2
1LL1222-3AB11-2■■■
415
557
315
Δ
50.7
2643
94.2
95.3
95.6
0.89
740
6.1
2.2
1LL1222-3AB31-2■■■
465
624
315
Δ
50.7
2961
94.4
95.5
95.8
0.90
820
6.4
2.2
1LL1222-3AB51-2■■■
540
724
315
Δ
50.7
3439
94.6
95.6
96.0
0.90
950
6.4
2.2
1LL1222-3AB71-2■■■
655
878
355
Δ
50.7
4171
94.4
95.6
95.9
0.89
1160
5.1
1.9
1LL1222-3BB51-2■■■
765
1026
355
Δ
50.6
4871
94.8
95.9
96.1
0.89
1360
5.7
2.0
1LL1222-3BB71-2■■■
1000 rpm, 6-pole
260
349
315
Δ
50.6
2483
93.8
95.0
95.3
0.82
510
6.0
1.9
1LL1222-3AC11-3■■■
335
449
315
Δ
50.6
3199
94.1
95.2
95.6
0.83
640
6.1
1.9
1LL1222-3AC31-3■■■
380
510
315
Δ
50.6
3630
94.3
95.4
95.7
0.84
720
6.2
1.9
1LL1222-3AC51-3■■■
425
570
315
Δ
50.6
4060
94.4
95.5
95.8
0.85
800
6.0
1.8
1LL1222-3AC71-3■■■
530
711
355
Δ
50.5
5065
94.5
95.5
95.6
0.86
980
7.2
2.0
1LL1222-3BC51-3■■■
585
784
355
Δ
50.5
5591
94.6
95.6
95.7
0.87
1060
7.2
1.8
1LL1222-3BC71-3■■■
750 rpm, 6-pole
210
282
315
Δ
38.1
2676
93.0
94.3
94.8
0.81
420
6.0
2.0
1LL1222-3AC11-4■■■
260
349
315
Δ
38.1
3314
93.2
94.5
95.0
0.82
510
6.3
2.1
1LL1222-3AC31-4■■■
290
389
315
Δ
38.1
3695
93.4
94.6
95.1
0.83
560
6.1
2.0
1LL1222-3AC51-4■■■
320
429
315
Δ
38.1
4076
93.3
94.6
95.2
0.85
600
5.9
1.8
1LL1222-3AC71-4■■■
380
510
355
Δ
38
4839
93.2
94.6
95.0
0.87
700
6.3
2.0
1LL1222-3BC51-4■■■
430
577
355
Δ
38
5476
93.5
94.7
95.1
0.87
790
6.6
1.8
1LL1222-3BC71-4■■■
For versions, see Article No. supplements and special versions
1LL1222-3AC71-4■■■
8/2
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Self-ventilated motors — open version
1LL1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
LpfA,
LWA,
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
tolerance
+3 dB(A)
no-load
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LL1212-3AB11-1...
1LL1212-3AB31-1...
1LL1212-3AB51-1...
1LL1212-3AB71-1...
1LL1212-3BB51-1...
1LL1212-3BB71-1...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
6SL3710-7LE41-2AA3
590
725
820
960
1230
1230
1LL1212-3AB11-2...
1LL1212-3AB31-2...
1LL1212-3AB51-2...
1LL1212-3AB71-2...
1LL1212-3BB51-2...
1LL1212-3BB71-2...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
6SL3710-7LE41-2AA3
477
725
725
960
1230
1230
1LL1212-3AC11-3...
1LL1212-3AC31-3...
1LL1212-3AC51-3...
1LL1212-3AC71-3...
1LL1212-3BC51-3...
1LL1212-3BC71-3...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
477
590
725
725
960
1230
1LL1212-3AC11-4...
1LL1212-3AC31-4...
1LL1212-3AC51-4...
1LL1212-3AC71-4...
1LL1212-3BC51-4...
1LL1212-3BC71-4...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LE33-8AA3
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
370
477
590
590
725
725
1LL1222-3AB11-1...
1LL1222-3AB31-1...
1LL1222-3AB51-1...
1LL1222-3AB71-1...
1LL1222-3BB51-1...
1LL1222-3BB71-1...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3370-1PE36-6AA0
6SL3710-1GE37-5AA3
6SL3710-1GE41-0AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-4AA3
6SL3710-2GE41-4AA3
640
725
960
960
1340
1340
1LL1222-3AB11-2...
1LL1222-3AB31-2...
1LL1222-3AB51-2...
1LL1222-3AB71-2...
1LL1222-3BB51-2...
1LL1222-3BB71-2...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3370-1PE36-6AA0
6SL3710-1GE38-4AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-4AA3
6SL3710-2GE41-6AA3
640
820
820
960
1340
1516
1LL1222-3AC11-3...
1LL1222-3AC31-3...
1LL1222-3AC51-3...
1LL1222-3AC71-3...
1LL1222-3BC51-3...
1LL1222-3BC71-3...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-1PE35-8AA0
6SL3370-1PE36-6AA0
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-1AA3
570
640
725
820
1092
1092
1LL1222-3AC11-4...
1LL1222-3AC31-4...
1LL1222-3AC51-4...
1LL1222-3AC71-4...
1LL1222-3BC51-4...
1LL1222-3BC71-4...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1PE34-6AA0
6SL3710-1PE35-8AA0
6SL3710-1PE35-8AA0
6SL3370-1PE36-6AA0
6SL3710-1PE37-4AA0
6SL3710-1GE38-4AA3
450
570
570
640
710
820
Siemens D 81.8 · 04/2014
8/3
8
© Siemens AG 2014
Self-ventilated motors — open version
1LL1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency
■ Selection and ordering data
Prated
8
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
TB/
Trated
1LL1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V
3000 rpm, 4-pole
305
409
315
Δ
100.8
971
94.9
95.6
95.5
0.89
400
5.3
1.8
1LL1212-3AB12-1■■■
410
550
315
Δ
100.7
1305
95.5
96.1
96.0
0.90
530
6.1
2.0
1LL1212-3AB32-1■■■
1LL1212-3AB52-1■■■
455
610
315
Δ
100.7
1449
95.6
96.3
96.1
0.90
580
6.5
2.1
480
644
315
Δ
100.8
1529
95.4
96.2
96.2
0.90
620
5.3
1.8
1LL1212-3AB72-1■■■
670
898
355
Δ
100.7
2135
94.6
95.3
94.9
0.89
880
4.8
1.7
1LL1212-3BB52-1■■■
1LL1212-3BB72-1■■■
680
912
355
Δ
100.8
2165
94.5
95.3
95.0
0.88
900
4.4
1.6
1500 rpm, 4-pole
275
369
315
Δ
50.6
1752
93.8
95.1
95.1
0.88
365
6.3
2.3
1LL1212-3AB12-2■■■
1LL1212-3AB32-2■■■
375
503
315
Δ
50.7
2388
94.0
95.1
95.4
0.89
490
6.1
2.2
440
590
315
Δ
50.6
2802
94.4
95.4
95.7
0.90
570
6.7
2.4
1LL1212-3AB52-2■■■
530
711
315
Δ
50.6
3375
94.7
95.7
95.9
0.90
680
7.5
2.2
1LL1212-3AB72-2■■■
655
878
355
Δ
50.6
4172
94.6
95.7
95.9
0.89
850
5.8
2.2
1LL1212-3BB52-2■■■
730
979
355
Δ
50.5
4649
94.8
95.8
96.1
0.89
950
6.2
2.1
1LL1212-3BB72-2■■■
1000 rpm, 6-pole
250
335
315
Δ
50.6
2389
93.9
95.0
95.3
0.82
355
6.5
2.1
1LL1212-3AC12-3■■■
1LL1212-3AC32-3■■■
305
409
315
Δ
50.6
2914
94.1
95.2
95.4
0.83
430
6.6
2.1
345
463
315
Δ
50.6
3297
94.0
95.2
95.5
0.84
480
6.2
1.9
1LL1212-3AC52-3■■■
385
516
315
Δ
50.6
3679
94.2
95.3
95.6
0.85
530
6.3
2.0
1LL1212-3AC72-3■■■
1LL1212-3BC52-3■■■
485
650
355
Δ
50.5
4635
94.2
95.3
95.4
0.86
660
7.2
2.1
545
731
355
Δ
50.4
5208
94.5
95.5
95.6
0.87
730
7.7
1.9
1LL1212-3BC72-3■■■
750 rpm, 6-pole
190
255
315
Δ
38
2420
92.8
94.1
94.5
0.80
280
6.5
2.2
1LL1212-3AC12-4■■■
235
315
315
Δ
38
2993
93.0
94.4
94.8
0.82
335
6.6
2.2
1LL1212-3AC32-4■■■
260
349
315
Δ
38.1
3314
93.0
94.4
94.9
0.84
365
6.1
2.0
1LL1212-3AC52-4■■■
295
396
315
Δ
38.1
3759
93.3
94.6
95.1
0.84
410
6.4
2.0
1LL1212-3AC72-4■■■
365
489
355
Δ
37.9
4650
93.4
94.6
95.0
0.86
500
7.2
2.1
1LL1212-3BC52-4■■■
390
523
355
Δ
38
4966
93.3
94.6
95.0
0.87
530
6.8
2.0
1LL1212-3BC72-4■■■
• Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V
3000 rpm, 4-pole
330
443
315
Δ
100.8
1051
95.0
95.8
95.7
0.88
470
5.0
1.7
1LL1222-3AB12-1■■■
1LL1222-3AB32-1■■■
415
557
315
Δ
100.8
1322
95.3
96.1
96.0
0.89
580
5.1
1.7
465
624
315
Δ
100.8
1481
95.4
96.2
96.2
0.90
650
5.3
1.8
1LL1222-3AB52-1■■■
535
717
315
Δ
100.8
1704
95.6
96.4
96.4
0.90
740
5.4
1.8
1LL1222-3AB72-1■■■
1LL1222-3BB52-1■■■
655
878
355
Δ
100.9
2085
94.4
95.2
94.9
0.88
940
4.1
1.5
745
999
355
Δ
100.8
2373
94.9
95.6
95.2
0.89
1060
4.7
1.7
1LL1222-3BB72-1■■■
1500 rpm, 4-pole
285
382
315
Δ
50.7
1815
93.9
95.1
95.3
0.88
410
5.9
2.1
1LL1222-3AB12-2■■■
425
570
315
Δ
50.6
2707
94.4
95.4
95.7
0.88
610
6.3
2.3
1LL1222-3AB32-2■■■
475
637
315
Δ
50.7
3025
94.5
95.5
95.8
0.90
660
6.4
2.2
1LL1222-3AB52-2■■■
530
711
315
Δ
50.7
3375
94.5
95.6
95.9
0.90
740
6.3
2.2
1LL1222-3AB72-2■■■
720
966
355
Δ
50.6
4585
94.7
95.8
96.1
0.88
1020
5.7
2.2
1LL1222-3BB52-2■■■
735
986
355
Δ
50.7
4681
94.5
95.7
96.1
0.89
1040
5.2
2.0
1LL1222-3BB72-2■■■
1000 rpm, 6-pole
245
329
315
Δ
50.6
2340
93.8
95.0
95.3
0.82
380
6.0
1.9
1LL1222-3AC12-3■■■
335
449
315
Δ
50.6
3200
94.2
95.3
95.6
0.83
510
6.2
2.0
1LL1222-3AC32-3■■■
380
510
315
Δ
50.6
3630
94.2
95.3
95.7
0.84
570
6.0
1.9
1LL1222-3AC52-3■■■
425
570
315
Δ
50.6
4061
94.4
95.5
95.8
0.84
640
6.2
1.8
1LL1222-3AC72-3■■■
515
691
355
Δ
50.5
4919
94.2
95.3
95.6
0.86
760
6.5
2.0
1LL1222-3BC52-3■■■
590
791
355
Δ
50.5
5638
94.5
95.5
95.7
0.87
850
7.0
1.8
1LL1222-3BC72-3■■■
750 rpm, 6-pole
205
275
315
Δ
38.1
2611
92.7
94.1
94.7
0.81
325
5.9
2.0
1LL1222-3AC12-4■■■
255
342
315
Δ
38.1
3249
93.2
94.5
95.0
0.82
395
6.0
2.0
1LL1222-3AC32-4■■■
285
382
315
Δ
38.1
3630
93.0
94.4
95.0
0.84
430
5.6
1.8
1LL1222-3AC52-4■■■
310
416
315
Δ
38.1
3948
93.2
94.5
95.1
0.85
465
5.6
1.8
1LL1222-3AC72-4■■■
390
523
355
Δ
38
4966
93.3
94.6
95.1
0.87
570
6.4
2.0
1LL1222-3BC52-4■■■
425
570
355
Δ
38
5412
93.5
94.8
95.2
0.87
620
6.6
1.8
1LL1222-3BC72-4■■■
For versions, see Article No. supplements and special versions
1LL1222-3AC72-4■■■
8/4
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Self-ventilated motors — open version
1LL1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
LpfA,
LWA,
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
tolerance
+3 dB(A)
no-load
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LL1212-3AB12-1...
1LL1212-3AB32-1...
1LL1212-3AB52-1...
1LL1212-3AB72-1...
1LL1212-3BB52-1...
1LL1212-3BB72-1...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-8AA3
6SL3710-7LG41-0AA3
400
560
710
710
880
1000
1LL1212-3AB12-2...
1LL1212-3AB32-2...
1LL1212-3AB52-2...
1LL1212-3AB72-2...
1LL1212-3BB52-2...
1LL1212-3BB72-2...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-8AA3
6SL3710-7LG41-0AA3
400
560
710
710
880
1000
1LL1212-3AC12-3...
1LL1212-3AC32-3...
1LL1212-3AC52-3...
1LL1212-3AC72-3...
1LL1212-3BC52-3...
1LL1212-3BC72-3...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
400
452
560
560
710
790
1LL1212-3AC12-4...
1LL1212-3AC32-4...
1LL1212-3AC52-4...
1LL1212-3AC72-4...
1LL1212-3BC52-4...
1LL1212-3BC72-4...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
320
400
400
452
560
560
1LL1222-3AB12-1...
1LL1222-3AB32-1...
1LL1222-3AB52-1...
1LL1222-3AB72-1...
1LL1222-3BB52-1...
1LL1222-3BB72-1...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
477
590
725
820
960
1092
1LL1222-3AB12-2...
1LL1222-3AB32-2...
1LL1222-3AB52-2...
1LL1222-3AB72-2...
1LL1222-3BB52-2...
1LL1222-3BB72-2...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-1AA3
477
725
725
820
1092
1092
1LL1222-3AC12-3...
1LL1222-3AC32-3...
1LL1222-3AC52-3...
1LL1222-3AC72-3...
1LL1222-3BC52-3...
1LL1222-3BC72-3...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
477
590
590
725
820
960
1LL1222-3AC12-4...
1LL1222-3AC32-4...
1LL1222-3AC52-4...
1LL1222-3AC72-4...
1LL1222-3BC52-4...
1LL1222-3BC72-4...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
370
477
477
477
590
725
Siemens D 81.8 · 04/2014
8
8/5
© Siemens AG 2014
Self-ventilated motors — open version
1LL1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency
■ Selection and ordering data
Prated
8
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
TB/
Trated
1LL1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V
3000 rpm, 4-pole
310
416
315
Δ
100.8
988
94.8
95.6
95.5
0.88
290
5.1
1.7
1LL1212-3AB13-1■■■
410
550
315
Δ
100.7
1306
95.3
96.1
96.0
0.90
375
5.8
1.9
1LL1212-3AB33-1■■■
1LL1212-3AB53-1■■■
475
637
315
Δ
100.7
1512
95.6
96.3
96.2
0.90
435
6.4
2.1
530
711
315
Δ
100.7
1688
95.7
96.4
96.3
0.91
480
6.3
2.0
1LL1212-3AB73-1■■■
675
905
355
Δ
100.8
2149
94.6
95.2
94.9
0.88
640
4.5
1.6
1LL1212-3BB53-1■■■
1LL1212-3BB73-1■■■
690
925
355
Δ
100.9
2197
94.4
95.2
95.0
0.88
650
4.2
1.5
1500 rpm, 4-pole
280
375
315
Δ
50.6
1783
93.8
95.1
95.1
0.87
270
6.3
2.3
1LL1212-3AB13-2■■■
1LL1212-3AB33-2■■■
390
523
315
Δ
50.6
2484
94.2
95.3
95.5
0.89
365
6.7
2.4
450
603
315
Δ
50.6
2866
94.5
95.5
95.8
0.89
420
6.9
2.5
1LL1212-3AB53-2■■■
515
691
315
Δ
50.6
3280
94.6
95.6
95.9
0.90
475
7.2
2.3
1LL1212-3AB73-2■■■
645
865
355
Δ
50.6
4107
94.5
95.6
95.9
0.89
600
5.5
2.1
1LL1212-3BB53-2■■■
700
939
355
Δ
50.6
4458
94.6
95.7
96.0
0.89
650
5.6
2.1
1LL1212-3BB73-2■■■
1000 rpm, 6-pole
230
308
315
Y
50.5
2198
93.9
95.0
95.2
0.81
235
6.9
2.2
1LL1212-3AC13-3■■■
1LL1212-3AC33-3■■■
305
409
315
Y
50.6
2915
94.0
95.1
95.4
0.83
305
6.5
2.0
350
469
315
Y
50.6
3345
94.1
95.2
95.6
0.84
345
6.3
2.0
1LL1212-3AC53-3■■■
395
530
315
Δ
50.6
3774
94.3
95.4
95.7
0.85
385
6.4
2.0
1LL1212-3AC73-3■■■
1LL1212-3BC53-3■■■
480
644
355
Δ
50.5
4588
94.2
95.2
95.4
0.86
465
7.2
2.2
550
738
355
Δ
50.4
5255
94.4
95.5
95.6
0.86
530
7.6
1.9
1LL1212-3BC73-3■■■
750 rpm, 6-pole
185
248
315
Y
38
2356
92.7
94.0
94.5
0.81
192
6.5
2.2
1LL1212-3AC13-4■■■
240
322
315
Y
38.1
3058
93.1
94.4
94.9
0.83
240
6.4
2.1
1LL1212-3AC33-4■■■
265
355
315
Δ
38.1
3377
93.1
94.4
95.0
0.84
265
6.1
2.0
1LL1212-3AC53-4■■■
300
402
315
Δ
38.1
3823
93.2
94.5
95.1
0.85
295
6.0
1.9
1LL1212-3AC73-4■■■
360
483
355
Y
37.9
4587
93.4
94.6
94.9
0.86
350
7.2
2.2
1LL1212-3BC53-4■■■
410
550
355
Δ
37.9
5223
93.6
94.7
95.1
0.87
395
7.3
1.9
1LL1212-3BC73-4■■■
• Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V
3000 rpm, 4-pole
310
416
315
Δ
100.8
987
95.0
95.7
95.6
0.89
320
5.4
1.8
1LL1222-3AB13-1■■■
1LL1222-3AB33-1■■■
395
530
315
Δ
100.7
1258
95.3
96.0
95.9
0.90
400
5.8
1.9
460
617
315
Δ
100.7
1464
95.6
96.3
96.2
0.90
465
6.5
2.2
1LL1222-3AB53-1■■■
520
697
315
Δ
100.7
1656
95.7
96.4
96.3
0.91
520
6.5
2.1
1LL1222-3AB73-1■■■
1LL1222-3BB53-1■■■
660
885
355
Δ
100.7
2103
94.6
95.2
94.9
0.89
680
4.7
1.7
670
898
355
Δ
100.8
2133
94.5
95.2
94.9
0.88
700
4.3
1.6
1LL1222-3BB73-1■■■
1500 rpm, 4-pole
280
375
315
Δ
50.6
1783
94.0
95.1
95.2
0.88
295
6.4
2.3
1LL1222-3AB13-2■■■
380
510
315
Δ
50.6
2420
94.1
95.2
95.5
0.89
390
6.4
2.3
1LL1222-3AB33-2■■■
430
577
315
Δ
50.6
2739
94.3
95.4
95.7
0.90
440
6.7
2.4
1LL1222-3AB53-2■■■
510
684
315
Δ
50.6
3248
94.6
95.6
95.9
0.90
520
7.0
2.3
1LL1222-3AB73-2■■■
670
898
355
Δ
50.6
4267
94.7
95.8
96.0
0.88
700
6.0
2.3
1LL1222-3BB53-2■■■
685
919
355
Δ
50.6
4362
94.6
95.7
96.0
0.89
700
5.6
2.1
1LL1222-3BB73-2■■■
1000 rpm, 6-pole
220
295
315
Y
50.5
2103
94.0
95.0
95.2
0.81
250
7.0
2.2
1LL1222-3AC13-3■■■
305
409
315
Δ
50.6
2915
94.0
95.1
95.4
0.83
340
6.5
2.1
1LL1222-3AC33-3■■■
355
476
315
Δ
50.6
3392
94.2
95.3
95.6
0.84
390
6.2
2.0
1LL1222-3AC53-3■■■
395
530
315
Δ
50.6
3774
94.3
95.4
95.7
0.84
430
6.7
2.0
1LL1222-3AC73-3■■■
475
637
355
Δ
50.5
4540
94.2
95.3
95.4
0.87
500
7.2
2.2
1LL1222-3BC53-3■■■
540
724
355
Δ
50.4
5159
94.5
95.5
95.6
0.86
580
7.7
1.9
1LL1222-3BC73-3■■■
750 rpm, 6-pole
180
241
315
Y
38.1
2294
92.7
94.0
94.5
0.81
205
6.4
2.1
1LL1222-3AC13-4■■■
245
329
315
Δ
38
3123
93.2
94.5
94.9
0.82
275
6.6
2.2
1LL1222-3AC33-4■■■
270
362
315
Δ
38.1
3440
93.2
94.5
95.0
0.84
300
6.2
2.1
1LL1222-3AC53-4■■■
290
389
315
Δ
38.1
3696
93.1
94.5
95.0
0.85
315
6.1
2.0
1LL1222-3AC73-4■■■
365
489
355
Δ
37.9
4650
93.4
94.6
95.0
0.86
390
7.3
2.1
1LL1222-3BC53-4■■■
395
530
355
Δ
38
5031
93.4
94.6
95.0
0.87
420
7.1
2.0
1LL1222-3BC73-4■■■
For versions, see Article No. supplements and special versions
1LL1222-3AC73-4■■■
8/6
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Self-ventilated motors — open version
1LL1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LL1212-3AB13-1...
1LL1212-3AB33-1...
1LL1212-3AB53-1...
1LL1212-3AB73-1...
1LL1212-3BB53-1...
1LL1212-3BB73-1...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
320
400
452
560
710
710
1LL1212-3AB13-2...
1LL1212-3AB33-2...
1LL1212-3AB53-2...
1LL1212-3AB73-2...
1LL1212-3BB53-2...
1LL1212-3BB73-2...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
320
400
452
560
710
710
1LL1212-3AC13-3...
1LL1212-3AC33-3...
1LL1212-3AC53-3...
1LL1212-3AC73-3...
1LL1212-3BC53-3...
1LL1212-3BC73-3...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
250
320
400
400
560
560
1LL1212-3AC13-4...
1LL1212-3AC33-4...
1LL1212-3AC53-4...
1LL1212-3AC73-4...
1LL1212-3BC53-4...
1LL1212-3BC73-4...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
6SL3710-7LG32-2AA3
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
208
250
320
320
400
400
1LL1222-3AB13-1...
1LL1222-3AB33-1...
1LL1222-3AB53-1...
1LL1222-3AB73-1...
1LL1222-3BB53-1...
1LL1222-3BB73-1...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH35-8AA3
6SL3710-1GH35-8AA3
6SL3710-1GH37-4AA3
6SL3710-1GH37-4AA3
320
400
560
560
710
710
1LL1222-3AB13-2...
1LL1222-3AB33-2...
1LL1222-3AB53-2...
1LL1222-3AB73-2...
1LL1222-3BB53-2...
1LL1222-3BB73-2...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH37-4AA3
6SL3710-1GH37-4AA3
320
400
452
560
710
710
1LL1222-3AC13-3...
1LL1222-3AC33-3...
1LL1222-3AC53-3...
1LL1222-3AC73-3...
1LL1222-3BC53-3...
1LL1222-3BC73-3...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GH32-6AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH37-4AA3
250
400
400
452
560
710
1LL1222-3AC13-4...
1LL1222-3AC33-4...
1LL1222-3AC53-4...
1LL1222-3AC73-4...
1LL1222-3BC53-4...
1LL1222-3BC73-4...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-1GH32-2AA3
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
208
320
320
320
400
452
Siemens D 81.8 · 04/2014
8
8/7
© Siemens AG 2014
Self-ventilated motors — open version
1LL1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency
■ Selection and ordering data
Prated
8
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
TB/
Trated
1LL1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V
3600 rpm, 4-pole
335
449
315
Δ
120.7
889
95.4
95.9
95.5
0.88
475
6.2
2.1
1LL1212-3AB15-5■■■
415
557
315
Δ
120.6
1101
95.8
96.2
95.8
0.90
580
7.3
2.4
1LL1212-3AB35-5■■■
1LL1212-3AB55-5■■■
440
590
315
Δ
120.7
1168
95.8
96.3
96.0
0.90
610
6.2
2.0
505
677
315
Δ
120.7
1340
95.9
96.5
96.2
0.91
690
6.7
2.1
1LL1212-3AB75-5■■■
3000 rpm, 4-pole
655
878
355
Δ
100.9
2085
94.4
95.2
94.9
0.88
940
4.1
1.5
1LL1212-3BB55-1■■■
750
1006
355
Δ
100.8
2389
94.9
95.6
95.2
0.89
1060
4.7
1.7
1LL1212-3BB75-1■■■
1800 rpm, 4-pole
340
456
315
Δ
60.6
1805
94.8
95.7
95.8
0.87
490
6.6
2.4
1LL1212-3AB15-6■■■
1LL1212-3AB35-6■■■
420
563
315
Δ
60.6
2229
95.0
95.9
96.1
0.89
590
6.7
2.4
465
624
315
Δ
60.6
2467
95.2
96.1
96.2
0.90
650
6.8
2.4
1LL1212-3AB55-6■■■
1LL1212-3AB75-6■■■
590
791
315
Δ
60.5
3130
95.7
96.5
96.5
0.89
830
8.1
2.4
795
1066
355
Δ
60.6
4219
95.2
96.1
96.3
0.89
1120
5.8
2.2
1LL1212-3BB55-6■■■
1LL1212-3BB75-6■■■
810
1086
355
Δ
60.7
4298
95.0
96.1
96.3
0.89
1140
5.3
2.0
1200 rpm, 6-pole
305
409
315
Δ
60.7
2428
94.2
95.3
95.6
0.82
470
5.8
1.8
1LL1212-3AC15-7■■■
1LL1212-3AC35-7■■■
375
503
315
Δ
60.7
2986
94.5
95.6
95.8
0.84
560
5.9
1.8
455
610
315
Δ
60.6
3622
94.9
95.8
96.0
0.84
680
6.3
1.9
1LL1212-3AC55-7■■■
1LL1212-3AC75-7■■■
485
650
315
Δ
60.6
3861
94.8
95.8
96.1
0.85
720
6.1
1.9
625
838
355
Δ
60.5
4975
94.9
95.8
95.8
0.86
910
7.1
2.0
1LL1212-3BC55-7■■■
665
892
355
Δ
60.5
5294
95.0
95.9
95.9
0.87
960
7.2
1.9
1LL1212-3BC75-7■■■
900 rpm, 6-pole
250
335
315
Δ
45.6
2654
93.6
94.8
95.2
0.81
390
6.0
2.0
1LL1212-3AC15-8■■■
1LL1212-3AC35-8■■■
315
422
315
Δ
45.6
3345
94
95.2
95.4
0.81
490
6.5
2.1
345
463
315
Δ
45.6
3662
93.8
95.1
95.5
0.84
520
5.8
1.9
1LL1212-3AC55-8■■■
380
510
315
Δ
45.6
4033
94
95.2
95.6
0.85
560
6.1
1.8
1LL1212-3AC75-8■■■
1LL1212-3BC55-8■■■
455
610
355
Δ
45.5
4829
93.9
95.1
95.4
0.87
660
6.4
2.0
515
691
355
Δ
45.5
5464
94.1
95.2
95.5
0.87
750
6.6
1.8
1LL1212-3BC75-8■■■
• Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G120P, SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V
3600 rpm, 4-pole
340
456
315
Δ
120.6
902
95.5
95.9
95.5
0.88
530
6.5
2.2
1LL1222-3AB15-5■■■
1LL1222-3AB35-5■■■
400
536
315
Δ
120.7
1062
95.7
96.2
95.9
0.90
610
6.3
2.0
450
603
315
Δ
120.6
1194
95.9
96.4
96.0
0.90
680
7.0
2.3
1LL1222-3AB55-5■■■
510
684
315
Δ
120.5
1353
96.1
96.5
96.1
0.91
760
8.1
2.6
1LL1222-3AB75-5■■■
3000 rpm, 4-pole
680
912
355
Δ
100.8
2167
94.7
95.4
95.0
0.88
1060
4.6
1.7
1LL1222-3BB55-1■■■
690
925
355
Δ
100.9
2197
94.6
95.3
95.1
0.88
1080
4.2
1.5
1LL1222-3BB75-1■■■
1800 rpm, 4-pole
340
456
315
Δ
60.6
1805
94.8
95.7
95.8
0.87
540
6.5
2.4
1LL1222-3AB15-6■■■
420
563
315
Δ
60.6
2229
95.1
96.0
96.1
0.89
650
6.9
2.4
1LL1222-3AB35-6■■■
475
637
315
Δ
60.6
2521
95.3
96.2
96.3
0.90
720
7.2
2.5
1LL1222-3AB55-6■■■
550
738
315
Δ
60.6
2918
95.4
96.3
96.4
0.90
830
7.3
2.5
1LL1222-3AB75-6■■■
735
986
355
Δ
60.7
3900
94.9
96.0
96.2
0.89
1120
5.2
1.9
1LL1222-3BB55-6■■■
850
1140
355
Δ
60.6
4511
95.3
96.2
96.4
0.89
1300
5.8
2.2
1LL1222-3BB75-6■■■
1200 rpm, 6-pole
325
436
315
Δ
60.6
2587
94.5
95.5
95.7
0.82
540
6.3
1.9
1LL1222-3AC15-7■■■
385
516
315
Δ
60.6
3065
94.6
95.6
95.9
0.83
640
6.1
1.9
1LL1222-3AC35-7■■■
440
590
315
Δ
60.6
3503
94.8
95.8
96.0
0.84
720
6.2
1.9
1LL1222-3AC55-7■■■
495
664
315
Δ
60.7
3941
94.8
95.9
96.1
0.85
800
5.9
1.8
1LL1222-3AC75-7■■■
605
811
355
Δ
60.5
4815
94.9
95.8
95.8
0.86
960
7.2
2.1
1LL1222-3BC55-7■■■
675
905
355
Δ
60.5
5373
95.0
95.9
95.9
0.87
1060
7.1
1.8
1LL1222-3BC75-7■■■
900 rpm, 6-pole
245
329
315
Δ
45.6
2601
93.7
94.8
95.1
0.80
425
6.4
2.1
1LL1222-3AC15-8■■■
1LL1222-3AC35-8■■■
305
409
315
Δ
45.6
3239
93.9
95.0
95.4
0.82
510
6.3
2.0
345
463
315
Δ
45.6
3664
93.9
95.1
95.5
0.84
570
6.0
1.9
1LL1222-3AC55-8■■■
375
503
315
Δ
45.6
3981
93.9
95.2
95.6
0.85
610
5.7
1.8
1LL1222-3AC75-8■■■
465
624
355
Δ
45.5
4935
94.0
95.1
95.4
0.87
740
6.7
2.0
1LL1222-3BC55-8■■■
520
697
355
Δ
45.5
5518
94.4
95.4
95.6
0.87
820
7.3
1.8
1LL1222-3BC75-8■■■
For versions, see Article No. supplements and special versions
1LL1222-3AC75-8■■■
8/8
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Self-ventilated motors — open version
1LL1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
LpfA,
LWA,
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
tolerance
+3 dB(A)
no-load
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LL1212-3AB15-5...
1LL1212-3AB35-5...
1LL1212-3AB55-5...
1LL1212-3AB75-5...
1230
1410
1590
1750
1280
1460
1640
1800
3.4
4.3
4.9
5.7
79
79
79
79
94
94
94
94
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
477
590
725
725
1LL1212-3BB55-1...
1LL1212-3BB75-1...
2190
2310
2240
2370
8.1
8.8
79
79
95
95
3300
3300
1XB7 740
6SL3710-7LE41-0AA3
2 x 1XB7 740 6SL3710-7LE41-2AA3
960
1230
1LL1212-3AB15-6...
1LL1212-3AB35-6...
1LL1212-3AB55-6...
1LL1212-3AB75-6...
1LL1212-3BB55-6...
1LL1212-3BB75-6...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
3000
3000
3000
3000
2200
2200
1XB7 731
1XB7 731
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
6SL3710-7LE41-2AA3
590
590
725
960
1230
1230
1LL1212-3AC15-7...
1LL1212-3AC35-7...
1LL1212-3AC55-7...
1LL1212-3AC75-7...
1LL1212-3BC55-7...
1LL1212-3BC75-7...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-0AA3
477
590
725
725
960
960
1LL1212-3AC15-8...
1LL1212-3AC35-8...
1LL1212-3AC55-8...
1LL1212-3AC75-8...
1LL1212-3BC55-8...
1LL1212-3BC75-8...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
477
590
590
590
725
820
1LL1222-3AB15-5...
1LL1222-3AB35-5...
1LL1222-3AB55-5...
1LL1222-3AB75-5...
1230
1410
1590
1750
1280
1460
1640
1800
3.4
4.3
4.9
5.7
79
79
79
79
94
94
94
94
3600
3600
3600
3600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1PE35-8AA0
6SL3370-1PE36-6AA0
6SL3710-1PE37-4AA0
6SL3710-1GE38-4AA3
570
640
710
820
1LL1222-3BB55-1...
1LL1222-3BB75-1...
2190
2310
2240
2370
8.1
8.8
79
79
95
95
3300
3300
2 x 1XB7 740 6SL3710-2GE41-1AA3
2 x 1XB7 740 6SL3710-2GE41-1AA3
1092
1092
1LL1222-3AB15-6...
1LL1222-3AB35-6...
1LL1222-3AB55-6...
1LL1222-3AB75-6...
1LL1222-3BB55-6...
1LL1222-3BB75-6...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
3000
3000
3000
3000
2200
2200
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-1PE35-8AA0
6SL3710-1PE37-4AA0
6SL3710-1GE37-5AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-4AA3
6SL3710-2GE41-4AA3
570
710
725
960
1340
1340
1LL1222-3AC15-7...
1LL1222-3AC35-7...
1LL1222-3AC55-7...
1LL1222-3AC75-7...
1LL1222-3BC55-7...
1LL1222-3BC75-7...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-1PE35-8AA0
6SL3370-1PE36-6AA0
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
570
640
725
820
960
1092
1LL1222-3AC15-8...
1LL1222-3AC35-8...
1LL1222-3AC55-8...
1LL1222-3AC75-8...
1LL1222-3BC55-8...
1LL1222-3BC75-8...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1PE34-6AA0
6SL3710-1PE35-8AA0
6SL3710-1PE35-8AA0
6SL3370-1PE36-6AA0
6SL3710-1GE38-4AA3
6SL3710-1GE38-4AA3
450
570
570
640
820
820
Siemens D 81.8 · 04/2014
8
8/9
© Siemens AG 2014
Self-ventilated motors — open version
1LL1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency
■ Selection and ordering data
Prated
8
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
TB/
Trated
1LL1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V
3600 rpm, 4-pole
315
422
315
Δ
120.7
836
95.2
95.7
95.3
0.88
355
5.9
2.0
1LL1212-3AB16-5■■■
400
536
315
Δ
120.6
1061
95.7
96.1
95.7
0.90
440
7.3
2.4
1LL1212-3AB36-5■■■
1LL1212-3AB56-5■■■
445
597
315
Δ
120.6
1181
95.8
96.3
95.9
0.90
485
7.7
2.5
505
677
315
Δ
120.5
1340
96.0
96.4
96.1
0.91
540
8.0
2.6
1LL1212-3AB76-5■■■
3000 rpm, 4-pole
630
845
355
Δ
100.9
2006
94.3
95.0
94.7
0.88
710
4.2
1.5
1LL1212-3BB56-1■■■
705
945
355
Δ
100.8
2246
94.6
95.3
95.0
0.89
790
4.5
1.6
1LL1212-3BB76-1■■■
1800 rpm, 4-pole
305
409
315
Δ
60.6
1619
94.6
95.5
95.6
0.88
345
6.6
2.4
1LL1212-3AB16-6■■■
1LL1212-3AB36-6■■■
400
536
315
Δ
60.5
2122
95.2
96.0
96.0
0.88
450
7.9
2.8
445
597
315
Δ
60.5
2361
95.2
96.1
96.2
0.89
490
7.7
2.7
1LL1212-3AB56-6■■■
1LL1212-3AB76-6■■■
545
731
315
Δ
60.5
2891
95.6
96.4
96.4
0.89
600
8.6
2.6
745
999
355
Δ
60.6
3954
95.1
96.0
96.2
0.89
830
6.0
2.2
1LL1212-3BB56-6■■■
1LL1212-3BB76-6■■■
825
1106
355
Δ
60.5
4378
95.3
96.2
96.3
0.89
910
6.5
2.3
1200 rpm, 6-pole
295
396
315
Δ
60.6
2348
94.3
95.3
95.5
0.82
355
6.5
2.0
1LL1212-3AC16-7■■■
1LL1212-3AC36-7■■■
360
483
315
Δ
60.6
2868
94.6
95.5
95.7
0.83
430
6.6
2.0
405
543
315
Δ
60.6
3224
94.6
95.6
95.8
0.84
475
6.3
1.9
1LL1212-3AC56-7■■■
1LL1212-3AC76-7■■■
450
603
315
Δ
60.6
3584
94.7
95.7
95.9
0.85
520
6.5
1.9
590
791
355
Δ
60.4
4698
94.9
95.7
95.7
0.86
680
8.0
2.1
1LL1212-3BC56-7■■■
640
858
355
Δ
60.4
5096
94.9
95.8
95.8
0.87
730
7.7
1.9
1LL1212-3BC76-7■■■
900 rpm, 6-pole
225
302
315
Y
45.6
2389
93.3
94.5
94.9
0.81
280
6.3
2.1
1LL1212-3AC16-8■■■
1LL1212-3AC36-8■■■
295
396
315
Δ
45.5
3132
94.0
95.1
95.3
0.82
360
6.8
2.2
325
436
315
Δ
45.6
3451
93.9
95.1
95.4
0.84
385
6.4
2.0
1LL1212-3AC56-8■■■
360
483
315
Δ
45.5
3823
94.1
95.2
95.5
0.84
425
6.8
1.9
1LL1212-3AC76-8■■■
1LL1212-3BC56-8■■■
435
583
355
Δ
45.5
4616
94.0
95.1
95.3
0.86
500
7.3
2.1
485
650
355
Δ
45.5
5147
94.1
95.2
95.4
0.87
550
7.3
1.9
1LL1212-3BC76-8■■■
• Insulation: Thermal class 180 (temperature class H), IP23 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V
3600 rpm, 4-pole
315
422
315
Δ
120.6
836
95.4
95.8
95.3
0.89
390
7.2
2.4
1LL1222-3AB16-5■■■
1LL1222-3AB36-5■■■
385
516
315
Δ
120.5
1021
95.7
96.1
95.6
0.89
475
7.8
2.6
425
570
315
Δ
120.5
1127
95.9
96.2
95.8
0.90
520
8.4
2.8
1LL1222-3AB56-5■■■
470
630
315
Δ
120.6
1247
95.8
96.4
96.1
0.91
560
6.9
2.2
1LL1222-3AB76-5■■■
3000 rpm, 4-pole
625
838
355
Δ
100.8
1990
94.4
95.1
94.7
0.88
780
4.3
1.6
1LL1222-3BB56-1■■■
700
939
355
Δ
100.7
2230
94.7
95.4
95.0
0.89
870
4.8
1.7
1LL1222-3BB76-1■■■
1800 rpm, 4-pole
300
402
315
Δ
60.6
1592
94.5
95.4
95.6
0.88
375
6.3
2.3
1LL1222-3AB16-6■■■
395
530
315
Δ
60.5
2096
95.1
95.9
96.0
0.88
490
7.7
2.7
1LL1222-3AB36-6■■■
440
590
315
Δ
60.5
2335
95.2
96.1
96.2
0.89
540
7.6
2.7
1LL1222-3AB56-6■■■
540
724
315
Δ
60.5
2865
95.6
96.4
96.4
0.89
660
9.0
2.6
1LL1222-3AB76-6■■■
740
992
355
Δ
60.6
3927
95.1
96.1
96.2
0.89
910
6.2
2.3
1LL1222-3BB56-6■■■
760
1019
355
Δ
60.6
4033
95.0
96.0
96.2
0.89
930
5.7
2.1
1LL1222-3BB76-6■■■
1200 rpm, 6-pole
275
369
315
Δ
60.7
2189
94.0
95.1
95.4
0.83
365
6.0
1.8
1LL1222-3AC16-7■■■
355
476
315
Δ
60.6
2828
94.5
95.5
95.7
0.83
470
6.6
2.0
1LL1222-3AC36-7■■■
405
543
315
Δ
60.6
3225
94.6
95.6
95.8
0.84
530
6.3
1.9
1LL1222-3AC56-7■■■
450
603
315
Δ
60.6
3584
94.8
95.8
96.0
0.85
580
6.7
2.0
1LL1222-3AC76-7■■■
560
751
355
Δ
60.5
4459
94.8
95.7
95.7
0.86
710
7.8
2.2
1LL1222-3BC56-7■■■
635
852
355
Δ
60.4
5055
95.0
95.9
95.8
0.86
810
8.4
2.0
1LL1222-3BC76-7■■■
900 rpm, 6-pole
230
308
315
Δ
45.6
2442
93.5
94.6
94.9
0.80
320
6.7
2.2
1LL1222-3AC16-8■■■
1LL1222-3AC36-8■■■
285
382
315
Δ
45.5
3025
93.9
95.0
95.2
0.81
390
7.1
2.3
325
436
315
Δ
45.5
3451
93.9
95.1
95.4
0.83
430
6.7
2.1
1LL1222-3AC56-8■■■
355
476
315
Δ
45.5
3769
94.1
95.2
95.5
0.84
465
6.8
2.0
1LL1222-3AC76-8■■■
430
577
355
Δ
45.5
4563
94.0
95.1
95.3
0.86
550
7.2
2.2
1LL1222-3BC56-8■■■
475
637
355
Δ
45.4
5043
94.1
95.2
95.4
0.87
600
7.5
2.0
1LL1222-3BC76-8■■■
For versions, see Article No. supplements and special versions
1LL1222-3AC76-8■■■
8/10
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Self-ventilated motors — open version
1LL1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LL1212-3AB16-5...
1LL1212-3AB36-5...
1LL1212-3AB56-5...
1LL1212-3AB76-5...
1230
1410
1590
1750
1280
1460
1640
1800
3.4
4.3
4.9
5.7
79
79
79
79
94
94
94
94
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
400
452
560
560
1LL1212-3BB56-1...
1LL1212-3BB76-1...
2190
2310
2240
2370
8.1
8.8
79
79
95
95
3300
3300
1XB7 740
1XB7 740
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
710
790
1LL1212-3AB16-6...
1LL1212-3AB36-6...
1LL1212-3AB56-6...
1LL1212-3AB76-6...
1LL1212-3BB56-6...
1LL1212-3BB76-6...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
3000
3000
3000
3000
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-8AA3
6SL3710-7LG41-0AA3
400
452
560
710
880
1000
1LL1212-3AC16-7...
1LL1212-3AC36-7...
1LL1212-3AC56-7...
1LL1212-3AC76-7...
1LL1212-3BC56-7...
1LL1212-3BC76-7...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
400
452
560
560
710
790
1LL1212-3AC16-8...
1LL1212-3AC36-8...
1LL1212-3AC56-8...
1LL1212-3AC76-8...
1LL1212-3BC56-8...
1LL1212-3BC76-8...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
320
400
400
452
560
560
1LL1222-3AB16-5...
1LL1222-3AB36-5...
1LL1222-3AB56-5...
1LL1222-3AB76-5...
1230
1410
1590
1750
1280
1460
1640
1800
3.4
4.3
4.9
5.7
79
79
79
79
94
94
94
94
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GF34-1AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
400
560
560
560
1LL1222-3BB56-1...
1LL1222-3BB76-1...
2190
2310
2240
2370
8.1
8.8
79
79
95
95
3300
3300
1XB7 740
1XB7 740
6SL3710-1GF38-1AA3
6SL3710-2GF41-1AA3
790
1036
1LL1222-3AB16-6...
1LL1222-3AB36-6...
1LL1222-3AB56-6...
1LL1222-3AB76-6...
1LL1222-3BB56-6...
1LL1222-3BB76-6...
1230
1410
1590
1750
2190
2310
1280
1460
1640
1800
2240
2370
3.4
4.3
4.9
5.7
8.1
8.8
79
79
79
79
79
79
94
94
94
94
95
95
3000
3000
3000
3000
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GF34-1AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-2GF41-1AA3
6SL3710-2GF41-1AA3
400
560
560
710
1036
1036
1LL1222-3AC16-7...
1LL1222-3AC36-7...
1LL1222-3AC56-7...
1LL1222-3AC76-7...
1LL1222-3BC56-7...
1LL1222-3BC76-7...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GF34-1AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
6SL3710-2GF38-6AA3
400
560
560
710
710
836
1LL1222-3AC16-8...
1LL1222-3AC36-8...
1LL1222-3AC56-8...
1LL1222-3AC76-8...
1LL1222-3BC56-8...
1LL1222-3BC76-8...
1260
1440
1620
1730
2180
2330
1310
1490
1670
1780
2240
2380
5.8
7.1
8.2
9.0
14.3
15.8
79
79
79
79
79
79
94
94
94
94
95
95
2500
2500
2500
2500
2200
2200
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GF33-3AA3
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
320
400
452
560
560
710
Siemens D 81.8 · 04/2014
8
8/11
© Siemens AG 2014
Self-ventilated motors — open version
Dimensions
1LL1 motors
■ Dimensional drawings
IM B5 type of construction
For terminal box dimensions, see Page 8/14.
L
LL
BE
HB'
HK
HC
GA
HD
AC
ØD
F
HB
AG
AD
BC
H
HA
EB
DB
BA
E
G_D081_XX_00416
C
ØK
B
BB
Ø K'
AA
A
AB
IM B35 and IM V1 types of construction
For flange dimensions, see Page 8/13 (Z = the number of retaining holes),
For terminal box dimensions, see Page 8/14
L
8
LL
HC
HB'
HK
HH
BE
AG
AD
LM
HB
ZxS
GA
AQ
AC
ØP
ØN
ØD
F
E
DB
G_D081_XX_00417
BA
LA
LE
C
Frame No. of
size
poles
Motor type
315
1LL12..-3A.1.-....
1LL12..-3A.3.-....
4, 6
4, 6
1LL12..-3A.5.-….
1LL12..-3A.7.-….
ØK
Ø K'
B
BB
AA
AB
AC AQ B
BA
BB
C
H
HA K
K' L
LM
D
560 120 680 630 670 630 180 780 180 315 28 28 35 1470 1615 85
● 560 120 680 630 670 630 180 780 200 315 28 28 35 1490 1635 95
560 120 680 630 670 835 180 985 180 315 28 28 35 1610 1775 85
DB
E
EB
F
GA
M20 170 140 22 90
M24 170 140 25 100
M20 170 140 22 90
● 560 120 680 630 670 835 180 985 200 315 28 28 35 1630 1775 95
M24 170 140 25 100
630 150 780 710 750 800 220 980 200 355 35 35 42 1730 1900 95
M24 170 140 25 100
● 630 150 780 710 750 800 220 980 224 355 35 35 42 1795 1965 100 M24 210 180 28 106
● Bearing design for increased cantilever forces, for type of construction IM B3 only.
8/12
AA
A
AB
Dimension designation acc. to IEC
A
1LL12..-3A.5.-....
1LL12..-3A.7.-....
355
M
H
HA
EB
HD
T
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Self-ventilated motors — open version
Dimensions
Flanges
G_D081_XX_00026
■ Dimensional drawings
(Z = the number of retaining holes)
Flange with through holes
Motor type
Frame size
No. of poles
Type of construction
Flange type
Dimension designation acc. to IEC
LA
1LL1
315
355
4, 6
4, 6
IM B35, IM V1
IM B35, IM V1
LE
M
N
P
S
T
Z
8
Flange
29
170
740
680
800
22
6
Flange (optional)
22
170
600
550
660
22
6
8
Flange
29
170
840
780
900
22
6
8
Flange (optional)
22
170
600
550
660
22
6
8
8
Siemens D 81.8 · 04/2014
8/13
© Siemens AG 2014
Self-ventilated motors — open version
Dimensions
Terminal boxes
■ Dimensional drawings
LL
BE
HB'
HK
HC
AG1
IM B3 type of construction
HD
HB
AG
AD
BC
G_D081_XX_00426
LL
HC
HB'
HK
HH
AG1
IM B35 and IM V1 types of construction
HB
8
HD
AG
AD
BE
G_D081_XX_00427
Motor
type
Frame
size
No. of
poles
Terminal box
Dimension designation acc. to IEC
AD
AG
AG1
BC
BE
HB
HB'
HH
HC
HD
HK
LL
1LL1
315
4, 6
1XB7 730
710
575
–
115
–
890
310
295
180
1025
255
345
1XB7 731
710
575
–
115
115
890
310
295
180
1025
255
345
1XB7 740
800
615
60
115
150
930
365
295
235
1110
340
425
GT640
655
555
–
115
110
870
225
295
155
970
170
310
1XB1 621
705
585
–
115
150
900
305
295
165
1020
250
330
1XB1 631
775
640
–
115
100
955
400
295
175
1090
320
555
1XB7 730
750
615
–
100
–
970
310
300
180
1105
255
345
1XB7 731
750
615
–
100
115
970
310
300
180
1105
255
345
1XB7 740
840
655
60
100
150
1010
365
300
235
1190
340
425
GT640
695
595
–
100
110
950
225
300
155
1050
170
310
1XB1 621
745
625
–
100
150
980
305
300
165
1100
250
330
1XB1 631
815
680
–
100
100
1035
400
300
175
1170
320
555
355
8/14
4, 6
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors –
open version
9/2
9
9/2
9/2
9/4
9/6
9/6
9/8
9/10
9/10
9/12
9/14
9/14
9/16
9/18
9/18
9/20
1LP1 motors for converter-fed
operation
Line voltage 400 V, 50 Hz
High Efficiency – low noise
High Efficiency – increased output
Line voltage 500 V, 50 Hz
High Efficiency – low noise
High Efficiency – increased output
Line voltage 690 V, 50 Hz
High Efficiency – low noise
High Efficiency – increased output
Line voltage 460 V, 60 Hz
High Efficiency – low noise
High Efficiency – increased output
Line voltage 575 V, 60 Hz
High Efficiency – low noise
High Efficiency – increased output
9/22
9/22
9/22
9/23
9/24
9/25
Dimensions
1LP1 motors
• Radially mounted equipment unit
• Axially mounted equipment unit
Flanges
Terminal boxes
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency – low noise
■ Selection and ordering data
Prated
9
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
T B/
Trated
1LP1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V
3000 rpm, 4-pole
335
449
315
Δ
100.9
1067
94.8
95.7
95.7
0.88
540
4.6
1.6
1LP1212-3AB11-1■■■
420
563
315
Δ
100.9
1338
95.2
96.1
96.1
0.89
670
5.0
1.7
1LP1212-3AB31-1■■■
1LP1212-3AB51-1■■■
470
630
315
Δ
100.8
1497
95.5
96.3
96.2
0.90
740
5.4
1.8
545
731
315
Δ
100.8
1736
95.7
96.4
96.4
0.91
840
5.8
1.9
1LP1212-3AB71-1■■■
685
919
355
Δ
100.8
2181
95.4
96.4
96.4
0.88
1100
4.2
1.5
1LP1212-3BB51-1■■■
1LP1212-3BB71-1■■■
690
925
355
Δ
100.9
2197
95.3
96.3
96.4
0.88
1100
4.0
1.4
1500 rpm, 4-pole
305
409
315
Δ
50.7
1943
94.1
95.3
95.7
0.88
495
5.7
2.1
1LP1212-3AB11-2■■■
1LP1212-3AB31-2■■■
405
543
315
Δ
50.6
2579
94.6
95.7
96.1
0.89
650
6.4
2.3
445
597
315
Δ
50.6
2834
94.7
95.8
96.2
0.90
700
6.6
2.3
1LP1212-3AB51-2■■■
510
684
315
Δ
50.6
3248
94.8
95.9
96.3
0.90
800
6.5
2.3
1LP1212-3AB71-2■■■
640
858
355
Δ
50.7
4076
94.6
95.8
96.3
0.89
1020
5.0
1.9
1LP1212-3BB51-2■■■
725
972
355
Δ
50.6
4616
94.9
96.0
96.4
0.89
1160
5.4
2.1
1LP1212-3BB71-2■■■
1000 rpm, 6-pole
280
375
315
Δ
50.7
2675
93.8
95.0
95.5
0.82
490
5.8
1.8
1LP1212-3AC11-3■■■
1LP1212-3AC31-3■■■
345
463
315
Δ
50.7
3295
94.1
95.3
95.7
0.83
590
5.9
1.8
390
523
315
Δ
50.7
3725
94.2
95.4
95.8
0.84
660
5.8
1.8
1LP1212-3AC51-3■■■
435
583
315
Δ
50.6
4157
94.5
95.6
95.9
0.84
740
6.2
1.8
1LP1212-3AC71-3■■■
1LP1212-3BC51-3■■■
545
731
355
Δ
50.5
5206
94.3
95.4
95.8
0.86
900
6.4
1.9
630
845
355
Δ
50.5
6019
94.6
95.6
95.9
0.86
1040
7.0
1.6
1LP1212-3BC71-3■■■
750 rpm, 6-pole
230
308
315
Δ
38.2
2930
92.3
93.8
94.6
0.81
410
5.4
1.8
1LP1212-3AC11-4■■■
285
382
315
Δ
38.2
3629
92.7
94.2
94.9
0.83
495
5.4
1.8
1LP1212-3AC31-4■■■
315
422
315
Δ
38.2
4012
92.8
94.3
95.0
0.85
530
5.3
1.7
1LP1212-3AC51-4■■■
350
469
315
Δ
38.2
4458
93.0
94.5
95.2
0.85
590
5.3
1.7
1LP1212-3AC71-4■■■
425
570
355
Δ
38.1
5414
92.7
94.3
94.9
0.87
700
5.6
1.8
1LP1212-3BC51-4■■■
485
650
355
Δ
38.1
6178
92.9
94.4
95.1
0.88
790
5.7
1.6
1LP1212-3BC71-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V
3000 rpm, 4-pole
325
436
315
Δ
100.9
1035
94.9
95.7
95.7
0.88
590
4.7
1.6
1LP1222-3AB11-1■■■
1LP1222-3AB31-1■■■
420
563
315
Δ
100.8
1338
95.4
96.1
96.1
0.89
750
5.2
1.8
475
637
315
Δ
100.7
1513
95.6
96.4
96.3
0.90
830
5.9
1.9
1LP1222-3AB51-1■■■
490
657
315
Δ
100.9
1561
95.4
96.2
96.3
0.90
860
5.0
1.7
1LP1222-3AB71-1■■■
1LP1222-3BB51-1■■■
710
952
355
Δ
100.7
2262
95.7
96.5
96.5
0.89
1260
4.8
1.7
720
966
355
Δ
100.8
2292
95.6
96.5
96.5
0.88
1280
4.4
1.6
1LP1222-3BB71-1■■■
1500 rpm, 4-pole
320
429
315
Δ
50.6
2038
94.3
95.4
95.8
0.87
590
6.0
2.2
1LP1222-3AB11-2■■■
400
536
315
Δ
50.6
2548
94.6
95.7
96.0
0.89
710
6.4
2.3
1LP1222-3AB31-2■■■
450
603
315
Δ
50.6
2866
94.8
95.8
96.2
0.90
790
6.6
2.3
1LP1222-3AB51-2■■■
520
697
315
Δ
50.6
3311
94.9
95.9
96.3
0.90
920
6.6
2.2
1LP1222-3AB71-2■■■
650
872
355
Δ
50.7
4139
94.7
95.9
96.3
0.89
1160
5.1
2.0
1LP1222-3BB51-2■■■
755
1012
355
Δ
50.6
4808
95.0
96.2
96.5
0.89
1340
5.7
2.1
1LP1222-3BB71-2■■■
1000 rpm, 6-pole
280
375
315
Δ
50.7
2675
93.7
95.0
95.5
0.82
550
5.5
1.8
1LP1222-3AC11-3■■■
350
469
315
Δ
50.7
3343
94.1
95.3
95.7
0.83
670
5.9
1.8
1LP1222-3AC31-3■■■
390
523
315
Δ
50.6
3725
94.3
95.5
95.8
0.84
740
6.1
1.9
1LP1222-3AC51-3■■■
440
590
315
Δ
50.7
4203
94.4
95.5
95.9
0.85
820
5.8
1.8
1LP1222-3AC71-3■■■
555
744
355
Δ
50.5
5301
94.5
95.5
95.8
0.86
1020
6.9
1.9
1LP1222-3BC51-3■■■
625
838
355
Δ
50.5
5970
94.5
95.6
95.9
0.87
1140
6.7
1.7
1LP1222-3BC71-3■■■
750 rpm, 6-pole
235
315
315
Δ
38.2
2993
92.5
94.0
94.7
0.81
470
5.3
1.8
1LP1222-3AC11-4■■■
290
389
315
Δ
38.2
3696
92.8
94.3
94.9
0.82
570
5.6
1.9
1LP1222-3AC31-4■■■
320
429
315
Δ
38.1
4076
93.0
94.4
95.1
0.84
610
5.6
1.8
1LP1222-3AC51-4■■■
350
469
315
Δ
38.2
4458
92.9
94.4
95.1
0.85
660
5.3
1.7
1LP1222-3AC71-4■■■
425
570
355
Δ
38.1
5414
92.8
94.3
95.0
0.87
790
5.5
1.8
1LP1222-3BC51-4■■■
485
650
355
Δ
38.1
6178
93.0
94.5
95.1
0.88
890
5.8
1.6
1LP1222-3BC71-4■■■
For versions, see Article No. supplements and special versions
1LP1222-3AC71-4■■■
9/2
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency – low noise
Motor type
mIM B3
mIM V1
J
LpfA,
LWA,
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
tolerance
+3 dB(A)
no-load
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LP1212-3AB11-1...
1LP1212-3AB31-1...
1LP1212-3AB51-1...
1LP1212-3AB71-1...
1LP1212-3BB51-1...
1LP1212-3BB71-1...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
6SL3710-7LE41-2AA3
590
725
820
960
1230
1230
1LP1212-3AB11-2...
1LP1212-3AB31-2...
1LP1212-3AB51-2...
1LP1212-3AB71-2...
1LP1212-3BB51-2...
1LP1212-3BB71-2...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-2AA3
6SL3710-7LE41-2AA3
590
725
725
820
1230
1230
1LP1212-3AC11-3...
1LP1212-3AC31-3...
1LP1212-3AC51-3...
1LP1212-3AC71-3...
1LP1212-3BC51-3...
1LP1212-3BC71-3...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
590
590
725
820
960
1230
1LP1212-3AC11-4...
1LP1212-3AC31-4...
1LP1212-3AC51-4...
1LP1212-3AC71-4...
1LP1212-3BC51-4...
1LP1212-3BC71-4...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
477
590
590
590
725
820
1LP1222-3AB11-1...
1LP1222-3AB31-1...
1LP1222-3AB51-1...
1LP1222-3AB71-1...
1LP1222-3BB51-1...
1LP1222-3BB71-1...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-4AA3
6SL3710-2GE41-4AA3
590
820
960
960
1340
1340
1LP1222-3AB11-2...
1LP1222-3AB31-2...
1LP1222-3AB51-2...
1LP1222-3AB71-2...
1LP1222-3BB51-2...
1LP1222-3BB71-2...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-4AA3
6SL3710-2GE41-4AA3
590
725
820
960
1340
1340
1LP1222-3AC11-3...
1LP1222-3AC31-3...
1LP1222-3AC51-3...
1LP1222-3AC71-3...
1LP1222-3BC51-3...
1LP1222-3BC71-3...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE38-4AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-4AA3
590
725
820
820
1092
1340
1LP1222-3AC11-4...
1LP1222-3AC31-4...
1LP1222-3AC51-4...
1LP1222-3AC71-4...
1LP1222-3BC51-4...
1LP1222-3BC71-4...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
477
590
725
725
820
960
Siemens D 81.8 · 04/2014
9
9/3
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency – increased output
■ Selection and ordering data
Prated
9
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
T B/
Trated
1LP1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 425 V
3000 rpm, 4-pole
370
496
315
Δ
101.0
1178
94.5
95.5
95.7
0.87
600
4.2
1.4
1LP1312-3AB11-1■■■
465
624
316
Δ
101.0
1480
94.9
95.9
96.0
0.89
740
4.5
1.5
1LP1312-3AB31-1■■■
530
711
317
Δ
100.9
1689
95.2
96.1
96.2
0.90
830
4.8
1.6
1LP1312-3AB51-1■■■
615
825
318
Δ
100.9
1959
95.4
96.3
96.4
0.90
960
5.0
1.7
1LP1312-3AB71-1■■■
725
972
355
Δ
101.0
2309
95.1
96.3
96.4
0.87
1180
3.7
1.4
1LP1312-3BB71-1■■■
1500 rpm, 4-pole
320
429
315
Δ
50.7
2037
93.8
95.1
95.6
0.88
520
5.5
2.0
1LP1312-3AB11-2■■■
450
603
316
Δ
50.7
2866
94.1
95.3
95.8
0.89
720
5.7
2.0
1LP1312-3AB31-2■■■
500
671
317
Δ
50.7
3184
94.2
95.4
95.9
0.90
790
5.8
2.1
1LP1312-3AB51-2■■■
575
771
318
Δ
50.7
3661
94.3
95.5
96.0
0.91
900
5.8
2.0
1LP1312-3AB71-2■■■
670
898
355
Δ
50.7
4267
94.4
95.7
96.2
0.89
1060
4.8
1.8
1LP1312-3BB51-2■■■
760
1019
355
Δ
50.7
4839
94.7
95.9
96.4
0.89
1200
5.2
2.0
1LP1312-3BB71-2■■■
1000 rpm, 6-pole
270
362
315
Δ
50.6
2579
93.8
95.0
95.4
0.82
470
6.0
1.9
1LP1312-3AC11-3■■■
370
496
316
Δ
50.7
3535
93.6
95.0
95.5
0.83
640
5.4
1.7
1LP1312-3AC31-3■■■
425
570
317
Δ
50.7
4061
93.7
95.1
95.6
0.84
720
5.3
1.7
1LP1312-3AC51-3■■■
480
644
318
Δ
50.7
4586
94.0
95.3
95.7
0.84
810
5.7
1.6
1LP1312-3AC71-3■■■
565
758
355
Δ
50.6
5397
94.1
95.4
95.7
0.87
920
6.2
1.8
1LP1312-3BC51-3■■■
650
872
355
Δ
50.5
6208
94.5
95.6
95.8
0.86
1080
6.7
1.6
1LP1312-3BC71-3■■■
750 rpm, 6-pole
250
335
315
Δ
38.3
3183
91.6
93.3
94.3
0.81
450
4.9
1.7
1LP1312-3AC11-4■■■
310
416
316
Δ
38.2
3948
92.0
93.8
94.6
0.83
540
5.0
1.6
1LP1312-3AC31-4■■■
345
463
317
Δ
38.3
4396
92.0
93.8
94.7
0.85
590
4.8
1.6
1LP1312-3AC51-4■■■
385
516
318
Δ
38.3
4905
92.2
94.0
94.8
0.85
650
4.8
1.5
1LP1312-3AC71-4■■■
435
583
355
Δ
38.1
5541
92.6
94.2
94.9
0.87
720
5.4
1.8
1LP1312-3BC51-4■■■
500
671
355
Δ
38.1
6368
92.8
94.3
95.0
0.88
820
5.5
1.6
1LP1312-3BC71-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 380 V
3000 rpm, 4-pole
360
483
315
Δ
101.0
1146
94.5
95.5
95.6
0.88
650
4.2
1.4
1LP1322-3AB11-1■■■
470
630
316
Δ
100.9
1496
95.0
96.0
96.1
0.89
840
4.7
1.6
1LP1322-3AB31-1■■■
540
724
317
Δ
100.9
1720
95.4
96.2
96.3
0.90
950
5.1
1.7
1LP1322-3AB51-1■■■
1LP1322-3AB71-1■■■
550
738
318
Δ
101.0
1751
95.0
96.0
96.2
0.89
980
4.4
1.5
750
1006
355
Δ
100.8
2389
95.6
96.5
96.5
0.88
1340
4.5
1.6
1LP1322-3BB51-1■■■
760
1019
355
Δ
100.9
2420
95.4
96.4
96.5
0.88
1360
4.2
1.5
1LP1322-3BB71-1■■■
1500 rpm, 4-pole
355
476
315
Δ
50.7
2260
93.8
95.1
95.6
0.87
650
5.5
2.0
1LP1322-3AB11-2■■■
445
597
316
Δ
50.7
2833
94.1
95.3
95.8
0.89
800
5.7
2.0
1LP1322-3AB31-2■■■
505
677
317
Δ
50.7
3216
94.2
95.5
96.0
0.90
890
5.9
2.1
1LP1322-3AB51-2■■■
585
784
318
Δ
50.7
3725
94.4
95.6
96.1
0.90
1040
5.9
2.0
1LP1322-3AB71-2■■■
685
919
355
Δ
50.7
4363
94.5
95.8
96.3
0.89
1220
4.9
1.9
1LP1322-3BB51-2■■■
795
1066
355
Δ
50.6
5062
94.9
96.1
96.4
0.89
1420
5.4
2.0
1LP1322-3BB71-2■■■
1000 rpm, 6-pole
265
355
315
Δ
50.7
2531
93.7
95.0
95.4
0.82
520
5.9
1.9
1LP1322-3AC11-3■■■
375
503
316
Δ
50.7
3582
93.7
95.0
95.5
0.83
720
5.5
1.7
1LP1322-3AC31-3■■■
430
577
317
Δ
50.7
4107
93.8
95.1
95.6
0.84
820
5.5
1.7
1LP1322-3AC51-3■■■
480
644
318
Δ
50.7
4586
93.9
95.2
95.7
0.85
900
5.3
1.6
1LP1322-3AC71-3■■■
575
771
355
Δ
50.5
5492
94.3
95.5
95.8
0.86
1060
6.6
1.8
1LP1322-3BC51-3■■■
645
865
355
Δ
50.5
6161
94.4
95.5
95.8
0.87
1180
6.5
1.6
1LP1322-3BC71-3■■■
750 rpm, 6-pole
255
342
315
Δ
38.3
3247
91.8
93.5
94.4
0.82
510
4.9
1.7
1LP1322-3AC11-4■■■
1LP1322-3AC31-4■■■
315
422
316
Δ
38.2
4011
92.2
93.8
94.6
0.82
620
5.1
1.7
350
469
317
Δ
38.2
4459
92.3
93.9
94.8
0.84
670
5.1
1.7
1LP1322-3AC51-4■■■
380
510
318
Δ
38.3
4842
92.2
94.0
94.8
0.85
720
4.9
1.5
1LP1322-3AC71-4■■■
440
590
355
Δ
38.1
5606
92.6
94.2
94.9
0.87
820
5.3
1.8
1LP1322-3BC51-4■■■
500
671
355
Δ
38.1
6368
92.9
94.4
95.0
0.88
910
5.7
1.6
1LP1322-3BC71-4■■■
For versions, see Article No. supplements and special versions
1LP1222-3AC71-4■■■
9/4
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 400 V, 50 Hz
High Efficiency – increased output
Motor type
mIM B3
mIM V1
J
LpfA,
LWA,
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
tolerance
+3 dB(A)
no-load
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LP1312-3AB11-1...
1LP1312-3AB31-1...
1LP1312-3AB51-1...
1LP1312-3AB71-1...
1LP1312-3BB71-1...
1280
1470
1640
1800
2380
1330
1520
1690
1850
2440
3.3
4.2
4.8
5.7
8.7
85
85
85
85
85
100.5
100.5
100.5
100.5
101
3600
3600
3600
3600
3300
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
725
820
960
960
1230
1LP1312-3AB11-2...
1LP1312-3AB31-2...
1LP1312-3AB51-2...
1LP1312-3AB71-2...
1LP1312-3BB51-2...
1LP1312-3BB71-2...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
6SL3710-7LE41-2AA3
590
725
820
960
1230
1230
1LP1312-3AC11-3...
1LP1312-3AC31-3...
1LP1312-3AC51-3...
1LP1312-3AC71-3...
1LP1312-3BC51-3...
1LP1312-3BC71-3...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
477
725
725
820
960
1230
1LP1312-3AC11-4...
1LP1312-3AC31-4...
1LP1312-3AC51-4...
1LP1312-3AC71-4...
1LP1312-3BC51-4...
1LP1312-3BC71-4...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
477
590
590
725
725
820
1LP1322-3AB11-1...
1LP1322-3AB31-1...
1LP1322-3AB51-1...
1LP1322-3AB71-1...
1LP1322-3BB51-1...
1LP1322-3BB71-1...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3600
3600
3600
3600
3300
3300
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-1GE37-5AA3
6SL3710-1GE41-0AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-4AA3
6SL3710-2GE41-6AA3
725
960
960
1092
1340
1516
1LP1322-3AB11-2...
1LP1322-3AB31-2...
1LP1322-3AB51-2...
1LP1322-3AB71-2...
1LP1322-3BB51-2...
1LP1322-3BB71-2...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-4AA3
6SL3710-2GE41-6AA3
725
820
960
1092
1340
1516
1LP1322-3AC11-3...
1LP1322-3AC31-3...
1LP1322-3AC51-3...
1LP1322-3AC71-3...
1LP1322-3BC51-3...
1LP1322-3BC71-3...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-4AA3
590
725
820
960
1092
1340
1LP1322-3AC11-4...
1LP1322-3AC31-4...
1LP1322-3AC51-4...
1LP1322-3AC71-4...
1LP1322-3BC51-4...
1LP1322-3BC71-4...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
590
725
725
725
820
960
Siemens D 81.8 · 04/2014
9
9/5
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency – low noise
■ Selection and ordering data
Prated
9
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
T B/
Trated
1LP1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V
3000 rpm, 4-pole
315
422
315
Δ
100.8
1003
94.9
95.7
95.6
0.88
415
5.1
1.7
1LP1212-3AB12-1■■■
415
557
315
Δ
100.7
1321
95.4
96.1
96.0
0.90
530
6.1
2.0
1LP1212-3AB32-1■■■
1LP1212-3AB52-1■■■
460
617
315
Δ
100.7
1465
95.6
96.3
96.2
0.90
590
6.3
2.1
480
644
315
Δ
100.8
1529
95.4
96.2
96.2
0.90
620
5.3
1.8
1LP1212-3AB72-1■■■
680
912
355
Δ
100.7
2166
95.5
96.4
96.4
0.89
880
4.8
1.7
1LP1212-3BB52-1■■■
1LP1212-3BB72-1■■■
700
939
355
Δ
100.8
2229
95.3
96.3
96.4
0.88
920
4.3
1.6
1500 rpm, 4-pole
285
382
315
Δ
50.7
1815
94.0
95.2
95.6
0.88
380
6.0
2.2
1LP1212-3AB12-2■■■
1LP1212-3AB32-2■■■
360
483
315
Δ
50.6
2293
94.4
95.5
95.9
0.89
470
6.4
2.3
420
563
315
Δ
50.6
2675
94.7
95.8
96.1
0.90
540
7.1
2.5
1LP1212-3AB52-2■■■
505
677
315
Δ
50.5
3216
95.1
96.0
96.3
0.89
660
7.7
2.3
1LP1212-3AB72-2■■■
675
905
355
Δ
50.6
4299
94.7
95.9
96.3
0.89
880
5.6
2.1
1LP1212-3BB52-2■■■
755
1012
355
Δ
50.6
4808
94.9
96.0
96.4
0.89
980
6.1
2.1
1LP1212-3BB72-2■■■
1000 rpm, 6-pole
270
362
315
Δ
50.6
2579
93.8
95.0
95.4
0.82
385
6.0
1.9
1LP1212-3AC12-3■■■
1LP1212-3AC32-3■■■
320
429
315
Δ
50.6
3058
94.0
95.2
95.6
0.83
450
6.3
2.0
355
476
315
Δ
50.6
3391
94.0
95.2
95.7
0.84
495
6.0
1.9
1LP1212-3AC52-3■■■
395
530
315
Δ
50.6
3774
94.2
95.4
95.8
0.85
540
6.2
1.9
1LP1212-3AC72-3■■■
1LP1212-3BC52-3■■■
510
684
355
Δ
50.5
4874
94.2
95.3
95.6
0.86
690
6.9
2.0
580
778
355
Δ
50.5
5542
94.4
95.5
95.7
0.87
780
7.2
1.8
1LP1212-3BC72-3■■■
750 rpm, 6-pole
215
288
315
Δ
38.1
2740
92.3
93.8
94.5
0.81
315
5.8
1.9
1LP1212-3AC12-4■■■
265
355
315
Δ
38.1
3375
92.6
94.1
94.7
0.83
375
5.9
1.9
1LP1212-3AC32-4■■■
285
382
315
Δ
38.1
3630
92.6
94.1
94.9
0.84
400
5.5
1.8
1LP1212-3AC52-4■■■
320
429
315
Δ
38.1
4076
93.0
94.4
95.0
0.84
450
5.8
1.8
1LP1212-3AC72-4■■■
415
557
355
Δ
38
5285
93.0
94.4
94.9
0.87
560
6.4
1.9
1LP1212-3BC52-4■■■
440
590
355
Δ
38
5605
92.9
94.3
94.9
0.88
590
6.1
1.8
1LP1212-3BC72-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V
3000 rpm, 4-pole
330
443
315
Δ
100.8
1051
95.0
95.8
95.7
0.88
470
5.0
1.7
1LP1222-3AB12-1■■■
1LP1222-3AB32-1■■■
420
563
315
Δ
100.8
1338
95.2
96.1
96.1
0.89
590
5.1
1.7
470
630
315
Δ
100.8
1497
95.4
96.2
96.2
0.90
650
5.3
1.7
1LP1222-3AB52-1■■■
535
717
315
Δ
100.8
1704
95.6
96.4
96.4
0.90
740
5.4
1.8
1LP1222-3AB72-1■■■
1LP1222-3BB52-1■■■
670
898
355
Δ
100.9
2133
95.3
96.3
96.4
0.88
950
4.1
1.5
765
1026
355
Δ
100.8
2437
95.7
96.5
96.5
0.89
1080
4.6
1.7
1LP1222-3BB72-1■■■
1500 rpm, 4-pole
305
409
315
Δ
50.7
1942
94.0
95.2
95.7
0.88
440
5.5
2.0
1LP1222-3AB12-2■■■
415
557
315
Δ
50.6
2643
94.7
95.7
96.1
0.88
590
6.6
2.4
1LP1222-3AB32-2■■■
455
610
315
Δ
50.6
2898
94.8
95.8
96.2
0.90
630
6.7
2.4
1LP1222-3AB52-2■■■
510
684
315
Δ
50.6
3248
94.8
95.9
96.3
0.90
710
6.6
2.3
1LP1222-3AB72-2■■■
715
959
355
Δ
50.6
4553
95.0
96.1
96.4
0.88
1020
5.7
2.2
1LP1222-3BB52-2■■■
725
972
355
Δ
50.6
4617
94.8
96.0
96.4
0.89
1020
5.3
2.0
1LP1222-3BB72-2■■■
1000 rpm, 6-pole
265
355
315
Δ
50.7
2531
93.7
95.0
95.5
0.82
410
5.5
1.8
1LP1222-3AC12-3■■■
355
476
315
Δ
50.6
3391
94.1
95.3
95.7
0.83
540
5.9
1.9
1LP1222-3AC32-3■■■
390
523
315
Δ
50.6
3726
94.2
95.4
95.8
0.84
590
5.8
1.8
1LP1222-3AC52-3■■■
435
583
315
Δ
50.6
4155
94.4
95.6
95.9
0.84
650
6.1
1.8
1LP1222-3AC72-3■■■
540
724
355
Δ
50.6
5158
94.2
95.4
95.7
0.87
780
6.3
1.9
1LP1222-3BC52-3■■■
620
831
355
Δ
50.5
5922
94.5
95.6
95.9
0.87
900
6.6
1.7
1LP1222-3BC72-3■■■
750 rpm, 6-pole
230
308
315
Δ
38.2
2931
92.2
93.8
94.6
0.81
365
5.2
1.8
1LP1222-3AC12-4■■■
285
382
315
Δ
38.2
3629
92.7
94.2
94.9
0.83
440
5.4
1.8
1LP1222-3AC32-4■■■
310
416
315
Δ
38.2
3949
92.6
94.2
95.0
0.84
470
5.1
1.7
1LP1222-3AC52-4■■■
340
456
315
Δ
38.2
4331
92.7
94.3
95.0
0.85
510
5.1
1.7
1LP1222-3AC72-4■■■
435
583
355
Δ
38.1
5540
92.9
94.4
95.0
0.87
640
5.7
1.8
1LP1222-3BC52-4■■■
485
650
355
Δ
38.1
6177
93.0
94.5
95.1
0.88
700
5.8
1.6
1LP1222-3BC72-4■■■
For versions, see Article No. supplements and special versions
1LP1222-3AC72-4■■■
9/6
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency – low noise
Motor type
mIM B3
mIM V1
J
LpfA,
LWA,
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
tolerance
+3 dB(A)
no-load
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LP1212-3AB12-1...
1LP1212-3AB32-1...
1LP1212-3AB52-1...
1LP1212-3AB72-1...
1LP1212-3BB52-1...
1LP1212-3BB72-1...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-8AA3
6SL3710-7LG41-0AA3
452
560
710
710
880
1000
1LP1212-3AB12-2...
1LP1212-3AB32-2...
1LP1212-3AB52-2...
1LP1212-3AB72-2...
1LP1212-3BB52-2...
1LP1212-3BB72-2...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-8AA3
6SL3710-7LG41-0AA3
400
560
560
710
880
1000
1LP1212-3AC12-3...
1LP1212-3AC32-3...
1LP1212-3AC52-3...
1LP1212-3AC72-3...
1LP1212-3BC52-3...
1LP1212-3BC72-3...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
400
452
560
560
710
790
1LP1212-3AC12-4...
1LP1212-3AC32-4...
1LP1212-3AC52-4...
1LP1212-3AC72-4...
1LP1212-3BC52-4...
1LP1212-3BC72-4...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
320
400
400
452
560
710
1LP1222-3AB12-1...
1LP1222-3AB32-1...
1LP1222-3AB52-1...
1LP1222-3AB72-1...
1LP1222-3BB52-1...
1LP1222-3BB72-1...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
477
590
725
820
960
1092
1LP1222-3AB12-2...
1LP1222-3AB32-2...
1LP1222-3AB52-2...
1LP1222-3AB72-2...
1LP1222-3BB52-2...
1LP1222-3BB72-2...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-1AA3
477
590
725
725
1092
1092
1LP1222-3AC12-3...
1LP1222-3AC32-3...
1LP1222-3AC52-3...
1LP1222-3AC72-3...
1LP1222-3BC52-3...
1LP1222-3BC72-3...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
477
590
590
725
820
960
1LP1222-3AC12-4...
1LP1222-3AC32-4...
1LP1222-3AC52-4...
1LP1222-3AC72-4...
1LP1222-3BC52-4...
1LP1222-3BC72-4...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GE33-8AA3
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
370
477
477
590
725
725
Siemens D 81.8 · 04/2014
9
9/7
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency – increased output
■ Selection and ordering data
Prated
9
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
T B/
Trated
1LP1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 520 V
3000 rpm, 4-pole
355
476
315
Δ
100.9
1130
94.5
95.5
95.6
0.88
470
4.5
1.5
1LP1312-3AB12-1■■■
470
630
316
Δ
100.8
1497
95.2
96.0
96.0
0.90
600
5.4
1.8
1LP1312-3AB32-1■■■
1LP1312-3AB52-1■■■
525
704
317
Δ
100.8
1672
95.3
96.1
96.2
0.90
670
5.6
1.8
540
724
318
Δ
100.9
1719
95.0
96.0
96.1
0.90
690
4.8
1.6
1LP1312-3AB72-1■■■
725
972
355
Δ
100.8
2310
95.4
96.3
96.4
0.88
950
4.4
1.6
1LP1312-3BB52-1■■■
1LP1312-3BB72-1■■■
735
986
355
Δ
100.9
2340
95.2
96.3
96.4
0.88
960
4.1
1.5
1500 rpm, 4-pole
285
382
315
Δ
50.7
1815
93.9
95.1
95.5
0.88
380
6.0
2.2
1LP1312-3AB12-2■■■
1LP1312-3AB32-2■■■
405
543
316
Δ
50.7
2579
93.8
95.1
95.7
0.90
530
5.6
2.0
475
637
317
Δ
50.7
3025
94.2
95.4
95.9
0.90
610
6.2
2.2
1LP1312-3AB52-2■■■
575
771
318
Δ
50.6
3661
94.6
95.7
96.1
0.90
740
6.9
2.0
1LP1312-3AB72-2■■■
710
952
355
Δ
50.6
4521
94.5
95.8
96.2
0.89
920
5.4
2.0
1LP1312-3BB52-2■■■
800
1073
355
Δ
50.6
5095
94.7
95.9
96.3
0.89
1040
5.7
1.9
1LP1312-3BB72-2■■■
1000 rpm, 6-pole
260
349
315
Δ
50.6
2483
93.8
95.0
95.4
0.82
370
6.2
2.0
1LP1312-3AC12-3■■■
1LP1312-3AC32-3■■■
335
449
316
Δ
50.6
3200
93.7
95.0
95.4
0.83
470
6.0
1.9
375
503
317
Δ
50.7
3583
93.7
95.0
95.5
0.84
520
5.7
1.8
1LP1312-3AC52-3■■■
435
583
318
Δ
50.7
4156
93.6
95.0
95.5
0.85
600
5.6
1.7
1LP1312-3AC72-3■■■
1LP1312-3BC52-3■■■
525
704
355
Δ
50.5
5015
94.1
95.3
95.6
0.86
710
6.7
2.0
605
811
355
Δ
50.5
5781
94.3
95.4
95.7
0.87
810
6.9
1.7
1LP1312-3BC72-3■■■
750 rpm, 6-pole
235
315
315
Δ
38.2
2995
91.6
93.2
94.2
0.81
345
5.3
1.8
1LP1312-3AC12-4■■■
280
375
316
Δ
38.2
3566
92.1
93.7
94.5
0.83
400
5.5
1.8
1LP1312-3AC32-4■■■
310
416
317
Δ
38.2
3950
91.9
93.6
94.5
0.85
435
5.1
1.7
1LP1312-3AC52-4■■■
355
476
318
Δ
38.2
4521
92.2
93.8
94.7
0.85
495
5.2
1.6
1LP1312-3AC72-4■■■
425
570
355
Δ
38.0
5413
92.9
94.3
94.9
0.87
580
6.2
1.8
1LP1312-3BC52-4■■■
455
610
355
Δ
38.1
5796
92.7
94.2
94.9
0.88
610
5.9
1.7
1LP1312-3BC72-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 480 V
3000 rpm, 4-pole
380
510
315
Δ
101.0
1210
94.6
95.6
95.7
0.88
540
4.3
1.5
1LP1322-3AB12-1■■■
1LP1322-3AB32-1■■■
470
630
316
Δ
101.0
1496
94.9
95.9
96.0
0.89
660
4.5
1.5
525
704
317
Δ
100.9
1671
95.1
96.1
96.2
0.89
740
4.6
1.6
1LP1322-3AB52-1■■■
605
811
318
Δ
100.9
1926
95.3
96.2
96.3
0.90
840
4.8
1.6
1LP1322-3AB72-1■■■
1LP1322-3BB52-1■■■
705
945
355
Δ
100.9
2245
95.2
96.2
96.4
0.87
1020
3.8
1.4
810
1086
355
Δ
100.8
2579
95.6
96.5
96.6
0.88
1140
4.4
1.6
1LP1322-3BB72-1■■■
1500 rpm, 4-pole
305
409
315
Δ
50.7
1942
93.8
95.1
95.6
0.88
440
5.5
2.0
1LP1322-3AB12-2■■■
460
617
316
Δ
50.7
2930
94.2
95.4
95.9
0.89
650
5.9
2.1
1LP1322-3AB32-2■■■
515
691
317
Δ
50.7
3279
94.2
95.5
96.0
0.90
720
5.9
2.1
1LP1322-3AB52-2■■■
575
771
318
Δ
50.7
3662
94.3
95.5
96.0
0.90
800
5.8
2.0
1LP1322-3AB72-2■■■
750
1006
355
Δ
50.6
4776
94.8
96.0
96.4
0.89
1060
5.5
2.1
1LP1322-3BB52-2■■■
760
1019
355
Δ
50.7
4839
94.6
95.9
96.4
0.89
1080
5.0
1.9
1LP1322-3BB72-2■■■
1000 rpm, 6-pole
250
335
315
Δ
50.6
2388
93.7
95.0
95.4
0.82
385
5.9
1.9
1LP1322-3AC12-3■■■
385
516
316
Δ
50.7
3678
93.6
95.0
95.5
0.83
590
5.4
1.7
1LP1322-3AC32-3■■■
430
577
317
Δ
50.7
4109
93.6
95.0
95.6
0.84
650
5.2
1.6
1LP1322-3AC52-3■■■
480
644
318
Δ
50.7
4586
93.9
95.2
95.7
0.84
720
5.5
1.6
1LP1322-3AC72-3■■■
560
751
355
Δ
50.6
5350
94.1
95.3
95.7
0.87
810
6.1
1.9
1LP1322-3BC52-3■■■
640
858
355
Δ
50.5
6114
94.4
95.5
95.8
0.87
930
6.4
1.6
1LP1322-3BC72-3■■■
750 rpm, 6-pole
250
335
315
Δ
38.3
3184
91.5
93.3
94.2
0.82
395
4.8
1.6
1LP1322-3AC12-4■■■
305
409
316
Δ
38.2
3885
92.1
93.8
94.6
0.83
470
5.0
1.7
1LP1322-3AC32-4■■■
335
449
317
Δ
38.3
4269
91.9
93.7
94.6
0.85
510
4.7
1.6
1LP1322-3AC52-4■■■
370
496
318
Δ
38.3
4716
91.9
93.8
94.7
0.85
560
4.7
1.5
1LP1322-3AC72-4■■■
450
603
355
Δ
38.1
5732
92.7
94.3
94.9
0.87
660
5.5
1.7
1LP1322-3BC52-4■■■
500
671
355
Δ
38.1
6369
92.8
94.4
95.0
0.88
720
5.7
1.6
1LP1322-3BC72-4■■■
For versions, see Article No. supplements and special versions
1LP1222-3AC72-4■■■
9/8
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 500 V, 50 Hz
High Efficiency – increased output
Motor type
mIM B3
mIM V1
J
LpfA,
LWA,
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
tolerance
+3 dB(A)
no-load
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LP1312-3AB12-1...
1LP1312-3AB32-1...
1LP1312-3AB52-1...
1LP1312-3AB72-1...
1LP1312-3BB52-1...
1LP1312-3BB72-1...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
6SL3710-7LG41-0AA3
6SL3710-7LG41-0AA3
560
710
710
710
1000
1000
1LP1312-3AB12-2...
1LP1312-3AB32-2...
1LP1312-3AB52-2...
1LP1312-3AB72-2...
1LP1312-3BB52-2...
1LP1312-3BB72-2...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
6SL3710-7LG41-0AA3
6SL3710-7LG41-3AA3
400
560
710
790
1000
1230
1LP1312-3AC12-3...
1LP1312-3AC32-3...
1LP1312-3AC52-3...
1LP1312-3AC72-3...
1LP1312-3BC52-3...
1LP1312-3BC72-3...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-8AA3
400
560
560
710
710
880
1LP1312-3AC12-4...
1LP1312-3AC32-4...
1LP1312-3AC52-4...
1LP1312-3AC72-4...
1LP1312-3BC52-4...
1LP1312-3BC72-4...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
400
400
452
560
710
710
1LP1322-3AB12-1...
1LP1322-3AB32-1...
1LP1322-3AB52-1...
1LP1322-3AB72-1...
1LP1322-3BB52-1...
1LP1322-3BB72-1...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-4AA3
590
725
820
960
1092
1340
1LP1322-3AB12-2...
1LP1322-3AB32-2...
1LP1322-3AB52-2...
1LP1322-3AB72-2...
1LP1322-3BB52-2...
1LP1322-3BB72-2...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-1AA3
477
725
725
820
1092
1092
1LP1322-3AC12-3...
1LP1322-3AC32-3...
1LP1322-3AC52-3...
1LP1322-3AC72-3...
1LP1322-3BC52-3...
1LP1322-3BC72-3...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
477
590
725
725
820
960
1LP1322-3AC12-4...
1LP1322-3AC32-4...
1LP1322-3AC52-4...
1LP1322-3AC72-4...
1LP1322-3BC52-4...
1LP1322-3BC72-4...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
477
477
590
590
725
725
Siemens D 81.8 · 04/2014
9
9/9
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency – low noise
■ Selection and ordering data
Prated
9
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
T B/
Trated
1LP1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V
3000 rpm, 4-pole
315
422
315
Δ
100.8
1003
94.8
95.6
95.6
0.88
295
5.0
1.7
1LP1212-3AB13-1■■■
415
557
315
Δ
100.7
1322
95.3
96.1
96.0
0.90
380
5.7
1.9
1LP1212-3AB33-1■■■
1LP1212-3AB53-1■■■
475
637
315
Δ
100.7
1512
95.6
96.3
96.2
0.90
435
6.4
2.1
530
711
315
Δ
100.7
1688
95.7
96.4
96.3
0.91
480
6.3
2.0
1LP1212-3AB73-1■■■
695
932
355
Δ
100.8
2214
95.4
96.3
96.4
0.88
650
4.4
1.6
1LP1212-3BB53-1■■■
1LP1212-3BB73-1■■■
705
945
355
Δ
100.9
2245
95.2
96.3
96.4
0.88
660
4.1
1.5
1500 rpm, 4-pole
290
389
315
Δ
50.6
1847
94.1
95.2
95.6
0.88
275
6.2
2.2
1LP1212-3AB13-2■■■
1LP1212-3AB33-2■■■
375
503
315
Δ
50.6
2388
94.6
95.6
95.9
0.88
355
6.9
2.5
430
577
315
Δ
50.6
2738
94.8
95.9
96.1
0.89
400
7.2
2.6
1LP1212-3AB53-2■■■
490
657
315
Δ
50.5
3120
94.9
96.0
96.2
0.90
450
7.6
2.4
1LP1212-3AB73-2■■■
660
885
355
Δ
50.6
4203
94.6
95.9
96.3
0.89
610
5.4
2.1
1LP1212-3BB53-2■■■
715
959
355
Δ
50.6
4553
94.7
95.9
96.3
0.89
660
5.6
2.1
1LP1212-3BB73-2■■■
1000 rpm, 6-pole
245
329
315
Y
50.6
2341
93.9
95.0
95.4
0.82
250
6.4
2.0
1LP1212-3AC13-3■■■
1LP1212-3AC33-3■■■
320
429
315
Y
50.6
3056
93.9
95.1
95.6
0.83
320
6.2
1.9
360
483
315
Y
50.6
3439
94.1
95.3
95.7
0.84
355
6.1
1.9
1LP1212-3AC53-3■■■
405
543
315
Δ
50.6
3870
94.3
95.4
95.8
0.85
395
6.2
1.9
1LP1212-3AC73-3■■■
1LP1212-3BC53-3■■■
505
677
355
Δ
50.5
4826
94.2
95.3
95.6
0.86
485
6.9
2.1
585
784
355
Δ
50.5
5590
94.4
95.5
95.7
0.87
560
7.2
1.8
1LP1212-3BC73-3■■■
750 rpm, 6-pole
210
282
315
Y
38.1
2675
92.2
93.7
94.4
0.81
220
5.7
1.9
1LP1212-3AC13-4■■■
270
362
315
Y
38.1
3438
92.6
94.1
94.8
0.83
275
5.6
1.9
1LP1212-3AC33-4■■■
290
389
315
Δ
38.1
3693
92.7
94.2
94.9
0.84
290
5.6
1.8
1LP1212-3AC53-4■■■
325
436
315
Δ
38.2
4138
92.9
94.3
95.0
0.85
320
5.6
1.8
1LP1212-3AC73-4■■■
405
543
355
Y
38
5157
93.0
94.4
94.9
0.87
390
6.4
1.9
1LP1212-3BC53-4■■■
465
624
355
Δ
38
5921
93.1
94.5
95.0
0.87
445
6.4
1.7
1LP1212-3BC73-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V
3000 rpm, 4-pole
320
429
315
Δ
100.8
1019
94.9
95.7
95.6
0.89
330
5.2
1.8
1LP1222-3AB13-1■■■
1LP1222-3AB33-1■■■
395
530
315
Δ
100.7
1258
95.3
96.1
96.0
0.90
400
5.8
1.9
460
617
315
Δ
100.7
1464
95.6
96.3
96.2
0.90
465
6.5
2.2
1LP1222-3AB53-1■■■
525
704
315
Δ
100.7
1672
95.7
96.4
96.3
0.91
520
6.5
2.1
1LP1222-3AB73-1■■■
1LP1222-3BB53-1■■■
675
905
355
Δ
100.8
2151
95.5
96.4
96.4
0.89
690
4.7
1.7
690
925
355
Δ
100.8
2197
95.3
96.3
96.4
0.88
710
4.2
1.5
1LP1222-3BB73-1■■■
1500 rpm, 4-pole
295
396
315
Δ
50.7
1879
94.1
95.3
95.7
0.88
310
6.1
2.2
1LP1222-3AB13-2■■■
370
496
315
Δ
50.6
2356
94.4
95.6
95.9
0.89
380
6.5
2.3
1LP1222-3AB33-2■■■
410
550
315
Δ
50.6
2611
94.7
95.8
96.1
0.90
415
7.1
2.5
1LP1222-3AB53-2■■■
490
657
315
Δ
50.6
3120
94.9
95.9
96.2
0.90
495
7.4
2.4
1LP1222-3AB73-2■■■
690
925
355
Δ
50.6
4394
94.9
96.0
96.3
0.88
710
6.0
2.3
1LP1222-3BB53-2■■■
695
932
355
Δ
50.6
4426
94.7
95.9
96.3
0.89
710
5.6
2.1
1LP1222-3BB73-2■■■
1000 rpm, 6-pole
245
329
315
Y
50.6
2342
93.8
95.0
95.4
0.82
275
6.4
2.0
1LP1222-3AC13-3■■■
320
429
315
Δ
50.6
3057
94.0
95.2
95.6
0.83
355
6.2
2.0
1LP1222-3AC33-3■■■
365
489
315
Δ
50.6
3486
94.2
95.3
95.7
0.84
400
6.1
1.9
1LP1222-3AC53-3■■■
400
536
315
Δ
50.6
3823
94.4
95.5
95.8
0.84
435
6.6
1.9
1LP1222-3AC73-3■■■
500
671
355
Δ
50.5
4775
94.2
95.3
95.6
0.86
530
6.7
2.1
1LP1222-3BC53-3■■■
575
771
355
Δ
50.5
5493
94.4
95.5
95.7
0.87
610
7.3
1.8
1LP1222-3BC73-3■■■
750 rpm, 6-pole
205
275
315
Y
38.2
2610
92.1
93.7
94.4
0.82
235
5.6
1.9
1LP1222-3AC13-4■■■
275
369
315
Δ
38.1
3505
92.8
94.2
94.8
0.82
310
5.9
1.9
1LP1222-3AC33-4■■■
290
389
315
Δ
38.1
3693
92.9
94.3
95.0
0.84
320
5.8
1.9
1LP1222-3AC53-4■■■
315
422
315
Δ
38.1
4011
92.8
94.3
95.0
0.85
345
5.6
1.8
1LP1222-3AC73-4■■■
410
550
355
Δ
38
5221
93.0
94.4
95.0
0.87
435
6.5
1.9
1LP1222-3BC53-4■■■
445
597
355
Δ
38
5668
93.0
94.4
95.0
0.88
470
6.3
1.7
1LP1222-3BC73-4■■■
For versions, see Article No. supplements and special versions
1LP1222-3AC73-4■■■
9/10
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency – low noise
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LP1212-3AB13-1...
1LP1212-3AB33-1...
1LP1212-3AB53-1...
1LP1212-3AB73-1...
1LP1212-3BB53-1...
1LP1212-3BB73-1...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
320
400
452
560
710
710
1LP1212-3AB13-2...
1LP1212-3AB33-2...
1LP1212-3AB53-2...
1LP1212-3AB73-2...
1LP1212-3BB53-2...
1LP1212-3BB73-2...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
320
400
400
452
710
710
1LP1212-3AC13-3...
1LP1212-3AC33-3...
1LP1212-3AC53-3...
1LP1212-3AC73-3...
1LP1212-3BC53-3...
1LP1212-3BC73-3...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
250
320
400
400
560
560
1LP1212-3AC13-4...
1LP1212-3AC33-4...
1LP1212-3AC53-4...
1LP1212-3AC73-4...
1LP1212-3BC53-4...
1LP1212-3BC73-4...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
250
320
320
320
400
452
1LP1222-3AB13-1...
1LP1222-3AB33-1...
1LP1222-3AB53-1...
1LP1222-3AB73-1...
1LP1222-3BB53-1...
1LP1222-3BB73-1...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH35-8AA3
6SL3710-1GH35-8AA3
6SL3710-1GH37-4AA3
6SL3710-1GH37-4AA3
400
400
560
560
710
710
1LP1222-3AB13-2...
1LP1222-3AB33-2...
1LP1222-3AB53-2...
1LP1222-3AB73-2...
1LP1222-3BB53-2...
1LP1222-3BB73-2...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH37-4AA3
6SL3710-1GH37-4AA3
320
400
452
560
710
710
1LP1222-3AC13-3...
1LP1222-3AC33-3...
1LP1222-3AC53-3...
1LP1222-3AC73-3...
1LP1222-3BC53-3...
1LP1222-3BC73-3...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH37-4AA3
320
400
400
452
560
710
1LP1222-3AC13-4...
1LP1222-3AC33-4...
1LP1222-3AC53-4...
1LP1222-3AC73-4...
1LP1222-3BC53-4...
1LP1222-3BC73-4...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-1GH32-6AA3
6SL3710-1GH33-3AA3
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
250
320
320
400
452
560
Siemens D 81.8 · 04/2014
9
9/11
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency – increased output
■ Selection and ordering data
Prated
9
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
T B/
Trated
1LP1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 730 V
3000 rpm, 4-pole
350
469
315
Δ
100.9
1114
94.4
95.4
95.5
0.88
330
4.5
1.5
1LP1312-3AB13-1■■■
465
624
316
Δ
100.8
1481
95.0
95.9
96.0
0.89
430
5.1
1.7
1LP1312-3AB33-1■■■
1LP1312-3AB53-1■■■
545
731
317
Δ
100.8
1736
95.3
96.2
96.2
0.90
500
5.6
1.8
605
811
318
Δ
100.8
1927
95.4
96.2
96.3
0.91
550
5.5
1.8
1LP1312-3AB73-1■■■
735
986
355
Δ
100.9
2340
95.3
96.3
96.4
0.88
690
4.2
1.5
1LP1312-3BB53-1■■■
1LP1312-3BB73-1■■■
740
992
355
Δ
100.9
2356
95.1
96.2
96.4
0.88
690
3.9
1.4
1500 rpm, 4-pole
295
396
315
Δ
50.6
1879
93.9
95.1
95.5
0.88
280
6.1
2.2
1LP1312-3AB13-2■■■
1LP1312-3AB33-2■■■
420
563
316
Δ
50.7
2675
94.1
95.3
95.7
0.89
390
6.3
2.2
485
650
317
Δ
50.6
3089
94.3
95.5
95.9
0.90
445
6.5
2.3
1LP1312-3AB53-2■■■
555
744
318
Δ
50.6
3535
94.5
95.6
96.0
0.90
510
6.7
2.1
1LP1312-3AB73-2■■■
695
932
355
Δ
50.7
4426
94.5
95.7
96.2
0.89
650
5.1
2.0
1LP1312-3BB53-2■■■
755
1012
355
Δ
50.7
4808
94.5
95.8
96.3
0.89
700
5.2
2.0
1LP1312-3BB73-2■■■
1000 rpm, 6-pole
235
315
315
Y
50.6
2246
93.8
95.0
95.3
0.82
240
6.7
2.1
1LP1312-3AC13-3■■■
1LP1312-3AC33-3■■■
320
429
316
Y
50.6
3056
93.8
95.0
95.5
0.83
320
6.2
1.9
390
523
317
Y
50.7
3726
93.6
95.0
95.5
0.84
385
5.6
1.8
1LP1312-3AC53-3■■■
445
597
318
Δ
50.7
4252
93.8
95.1
95.6
0.85
435
5.7
1.7
1LP1312-3AC73-3■■■
1LP1312-3BC53-3■■■
525
704
355
Δ
50.5
5014
94.0
95.2
95.6
0.86
510
6.5
2.0
605
811
355
Δ
50.5
5781
94.3
95.4
95.7
0.87
580
6.9
1.7
1LP1312-3BC73-3■■■
750 rpm, 6-pole
225
302
315
Y
38.2
2867
91.6
93.2
94.1
0.81
235
5.3
1.8
1LP1312-3AC13-4■■■
290
389
316
Y
38.2
3693
92.0
93.7
94.5
0.84
290
5.3
1.7
1LP1312-3AC33-4■■■
315
422
317
Δ
38.2
4013
92.0
93.7
94.6
0.84
315
5.2
1.7
1LP1312-3AC53-4■■■
355
476
318
Δ
38.2
4523
92.1
93.9
94.7
0.85
350
5.1
1.6
1LP1312-3AC73-4■■■
415
557
355
Y
38.0
5285
92.9
94.3
94.9
0.87
400
6.3
1.9
1LP1312-3BC53-4■■■
470
630
355
Δ
38.0
5986
93.1
94.5
95.0
0.87
450
6.4
1.7
1LP1312-3BC73-4■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 660 V
3000 rpm, 4-pole
360
483
315
Δ
100.9
1146
94.5
95.5
95.6
0.88
375
4.6
1.6
1LP1322-3AB13-1■■■
1LP1322-3AB33-1■■■
440
590
316
Δ
100.8
1402
95.0
95.9
96.0
0.89
450
5.1
1.7
530
711
317
Δ
100.8
1688
95.4
96.2
96.2
0.90
540
5.6
1.9
1LP1322-3AB53-1■■■
600
805
318
Δ
100.8
1911
95.4
96.3
96.3
0.91
600
5.6
1.8
1LP1322-3AB73-1■■■
1LP1322-3BB53-1■■■
715
959
355
Δ
100.8
2276
95.3
96.3
96.4
0.88
740
4.4
1.6
725
972
355
Δ
100.9
2309
95.2
96.2
96.4
0.88
750
4.0
1.5
1LP1322-3BB73-1■■■
1500 rpm, 4-pole
305
409
315
Δ
50.7
1943
93.8
95.1
95.6
0.88
320
5.9
2.1
1LP1322-3AB13-2■■■
410
550
316
Δ
50.7
2611
93.9
95.2
95.7
0.89
425
5.8
2.1
1LP1322-3AB33-2■■■
465
624
317
Δ
50.7
2962
94.1
95.4
95.9
0.90
475
6.2
2.2
1LP1322-3AB53-2■■■
555
744
318
Δ
50.7
3534
94.4
95.6
96.0
0.90
560
6.5
2.1
1LP1322-3AB73-2■■■
730
979
355
Δ
50.6
4649
94.7
95.9
96.3
0.88
760
5.6
2.1
1LP1322-3BB53-2■■■
740
992
355
Δ
50.7
4712
94.5
95.8
96.3
0.89
760
5.2
2.0
1LP1322-3BB73-2■■■
1000 rpm, 6-pole
235
315
315
Y
50.6
2246
93.8
95.0
95.3
0.82
265
6.6
2.1
1LP1322-3AC13-3■■■
330
443
316
Δ
50.6
3152
93.7
95.0
95.4
0.83
365
6.1
1.9
1LP1322-3AC33-3■■■
400
536
317
Δ
50.7
3822
93.6
95.0
95.5
0.85
435
5.6
1.7
1LP1322-3AC53-3■■■
445
597
318
Δ
50.6
4251
93.9
95.1
95.6
0.84
485
5.9
1.7
1LP1322-3AC73-3■■■
520
697
355
Δ
50.5
4967
94.0
95.2
95.6
0.87
550
6.5
2.0
1LP1322-3BC53-3■■■
595
798
355
Δ
50.5
5686
94.3
95.5
95.7
0.87
630
7.1
1.7
1LP1322-3BC73-3■■■
750 rpm, 6-pole
220
295
315
Y
38.2
2802
91.5
93.2
94.1
0.82
250
5.2
1.7
1LP1322-3AC13-4■■■
300
402
316
Δ
38.2
3820
92.1
93.7
94.5
0.83
335
5.4
1.8
1LP1322-3AC33-4■■■
320
429
317
Δ
38.2
4076
92.2
93.8
94.6
0.84
355
5.2
1.7
1LP1322-3AC53-4■■■
345
463
318
Δ
38.2
4394
92.0
93.8
94.7
0.85
380
5.1
1.7
1LP1322-3AC73-4■■■
420
563
355
Δ
38.0
5349
92.9
94.4
94.9
0.87
445
6.3
1.9
1LP1322-3BC53-4■■■
460
617
355
Δ
38.0
5857
92.8
94.3
94.9
0.88
485
6.1
1.7
1LP1322-3BC73-4■■■
For versions, see Article No. supplements and special versions
1LP1222-3AC73-4■■■
9/12
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 690 V, 50 Hz
High Efficiency – increased output
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LP1312-3AB13-1...
1LP1312-3AB33-1...
1LP1312-3AB53-1...
1LP1312-3AB73-1...
1LP1312-3BB53-1...
1LP1312-3BB73-1...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3600
3600
3600
3600
3300
3300
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
400
452
560
560
710
710
1LP1312-3AB13-2...
1LP1312-3AB33-2...
1LP1312-3AB53-2...
1LP1312-3AB73-2...
1LP1312-3BB53-2...
1LP1312-3BB73-2...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
320
400
452
560
710
710
1LP1312-3AC13-3...
1LP1312-3AC33-3...
1LP1312-3AC53-3...
1LP1312-3AC73-3...
1LP1312-3BC53-3...
1LP1312-3BC73-3...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
250
320
400
452
560
710
1LP1312-3AC13-4...
1LP1312-3AC33-4...
1LP1312-3AC53-4...
1LP1312-3AC73-4...
1LP1312-3BC53-4...
1LP1312-3BC73-4...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 730
1XB7 730
1XB7 731
1XB7 731
6SL3710-7LG32-6AA3
6SL3710-7LG33-3AA3
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
250
320
320
400
400
452
1LP1322-3AB13-1...
1LP1322-3AB33-1...
1LP1322-3AB53-1...
1LP1322-3AB73-1...
1LP1322-3BB53-1...
1LP1322-3BB73-1...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3600
3600
3600
3600
3300
3300
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH37-4AA3
6SL3710-1GH38-1AA3
6SL3710-1GH38-1AA3
400
452
560
710
790
790
1LP1322-3AB13-2...
1LP1322-3AB33-2...
1LP1322-3AB53-2...
1LP1322-3AB73-2...
1LP1322-3BB53-2...
1LP1322-3BB73-2...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GH33-3AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH35-8AA3
6SL3710-1GH38-1AA3
6SL3710-1GH38-1AA3
320
452
560
560
790
790
1LP1322-3AC13-3...
1LP1322-3AC33-3...
1LP1322-3AC53-3...
1LP1322-3AC73-3...
1LP1322-3BC53-3...
1LP1322-3BC73-3...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GH33-3AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
6SL3710-1GH35-8AA3
6SL3710-1GH37-4AA3
320
400
452
560
560
710
1LP1322-3AC13-4...
1LP1322-3AC33-4...
1LP1322-3AC53-4...
1LP1322-3AC73-4...
1LP1322-3BC53-4...
1LP1322-3BC73-4...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-1GH32-6AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-1AA3
6SL3710-1GH34-7AA3
6SL3710-1GH35-8AA3
250
400
400
400
452
560
Siemens D 81.8 · 04/2014
9
9/13
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency – low noise
■ Selection and ordering data
Prated
9
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
T B/
Trated
1LP1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V
3600 rpm, 4-pole
365
489
315
Δ
120.7
969
95.2
95.7
95.3
0.88
520
5.7
1.9
1LP1212-3AB15-5■■■
455
610
315
Δ
120.6
1207
95.6
96.1
95.7
0.90
630
6.7
2.2
1LP1212-3AB35-5■■■
1LP1212-3AB55-5■■■
470
630
315
Δ
120.8
1247
95.6
96.1
95.9
0.90
650
5.8
1.9
540
724
315
Δ
120.7
1433
95.8
96.3
96.1
0.90
750
6.2
2.0
1LP1212-3AB75-5■■■
3000 rpm, 4-pole
670
898
355
Δ
100.9
2133
95.3
96.3
96.4
0.88
950
4.1
1.5
1LP1212-3BB55-1■■■
765
1026
355
Δ
100.8
2437
95.7
96.5
96.5
0.89
1080
4.6
1.7
1LP1212-3BB75-1■■■
1800 rpm, 4-pole
360
483
315
Δ
60.6
1911
94.9
95.9
96.1
0.87
520
6.2
2.2
1LP1212-3AB15-6■■■
1LP1212-3AB35-6■■■
440
590
315
Δ
60.6
2335
95.1
96.1
96.3
0.89
620
6.4
2.2
490
657
315
Δ
60.6
2600
95.2
96.2
96.5
0.90
680
6.5
2.3
1LP1212-3AB55-6■■■
1LP1212-3AB75-6■■■
620
831
315
Δ
60.5
3290
95.7
96.5
96.7
0.90
860
7.8
2.2
795
1066
355
Δ
60.6
4219
95.4
96.4
96.7
0.89
1120
5.8
2.2
1LP1212-3BB55-6■■■
1LP1212-3BB75-6■■■
805
1080
355
Δ
60.7
4272
95.3
96.4
96.7
0.89
1120
5.4
2.0
1200 rpm, 6-pole
310
416
315
Δ
60.7
2468
94.3
95.5
95.9
0.82
475
5.7
1.7
1LP1212-3AC15-7■■■
1LP1212-3AC35-7■■■
380
510
315
Δ
60.7
3026
94.6
95.7
96.0
0.84
570
5.8
1.8
450
603
315
Δ
60.6
3582
95.0
96.0
96.2
0.84
670
6.4
1.9
1LP1212-3AC55-7■■■
1LP1212-3AC75-7■■■
475
637
315
Δ
60.6
3781
95.0
96.0
96.3
0.84
710
6.2
1.9
625
838
355
Δ
60.5
4975
95.0
96.0
96.1
0.86
910
7.1
2.0
1LP1212-3BC55-7■■■
685
919
355
Δ
60.5
5453
95.1
96.0
96.2
0.87
990
7.0
1.8
1LP1212-3BC75-7■■■
900 rpm, 6-pole
270
362
315
Δ
45.7
2865
93.4
94.7
95.3
0.82
420
5.6
1.8
1LP1212-3AC15-8■■■
1LP1212-3AC35-8■■■
340
456
315
Δ
45.6
3609
93.9
95.1
95.5
0.82
520
6.2
2.0
360
483
315
Δ
45.7
3821
93.7
95.0
95.5
0.85
540
5.6
1.8
1LP1212-3AC55-8■■■
395
530
315
Δ
45.6
4193
93.9
95.2
95.6
0.85
590
5.8
1.8
1LP1212-3AC75-8■■■
1LP1212-3BC55-8■■■
490
657
355
Δ
45.6
5202
93.7
95.0
95.5
0.87
710
6.0
1.9
560
751
355
Δ
45.6
5944
93.9
95.2
95.6
0.87
810
6.1
1.7
1LP1212-3BC75-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V
3600 rpm, 4-pole
370
496
315
Δ
120.7
982
95.3
95.8
95.3
0.88
580
5.9
2.0
1LP1222-3AB15-5■■■
1LP1222-3AB35-5■■■
435
583
315
Δ
120.7
1154
95.5
96.0
95.7
0.89
670
5.7
1.9
485
650
315
Δ
120.7
1287
95.7
96.2
95.9
0.90
740
6.4
2.1
1LP1222-3AB55-5■■■
560
751
315
Δ
120.6
1486
95.9
96.4
96.1
0.91
840
7.3
2.4
1LP1222-3AB75-5■■■
3000 rpm, 4-pole
695
932
355
Δ
100.8
2214
95.6
96.5
96.5
0.88
1080
4.5
1.6
1LP1222-3BB55-1■■■
700
939
355
Δ
100.9
2229
95.4
96.4
96.5
0.88
1080
4.2
1.5
1LP1222-3BB75-1■■■
1800 rpm, 4-pole
360
483
315
Δ
60.6
1911
94.9
95.9
96.1
0.87
570
6.2
2.2
1LP1222-3AB15-6■■■
445
597
315
Δ
60.6
2362
95.1
96.1
96.3
0.89
680
6.6
2.3
1LP1222-3AB35-6■■■
500
671
315
Δ
60.6
2654
95.3
96.3
96.5
0.90
760
6.8
2.4
1LP1222-3AB55-6■■■
580
778
315
Δ
60.6
3077
95.4
96.4
96.6
0.90
880
6.9
2.4
1LP1222-3AB75-6■■■
735
986
355
Δ
60.7
3901
95.2
96.3
96.6
0.89
1120
5.2
1.9
1LP1222-3BB55-6■■■
850
1140
355
Δ
60.6
4510
95.5
96.5
96.8
0.89
1300
5.8
2.2
1LP1222-3BB75-6■■■
1200 rpm, 6-pole
330
443
315
Δ
60.6
2627
94.7
95.7
96.0
0.82
550
6.2
1.9
1LP1222-3AC15-7■■■
395
530
315
Δ
60.7
3145
94.7
95.8
96.1
0.83
650
6.0
1.8
1LP1222-3AC35-7■■■
435
583
315
Δ
60.6
3463
94.9
96.0
96.2
0.84
710
6.3
1.9
1LP1222-3AC55-7■■■
490
657
315
Δ
60.6
3901
95.0
96.0
96.3
0.85
790
6.0
1.8
1LP1222-3AC75-7■■■
615
825
355
Δ
60.5
4895
95.0
96.0
96.1
0.86
980
7.1
2.0
1LP1222-3BC55-7■■■
685
919
355
Δ
60.5
5453
95.1
96.1
96.2
0.87
1080
7.0
1.8
1LP1222-3BC75-7■■■
900 rpm, 6-pole
265
355
315
Δ
45.6
2814
93.5
94.7
95.2
0.80
460
5.9
1.9
1LP1222-3AC15-8■■■
1LP1222-3AC35-8■■■
330
443
315
Δ
45.7
3502
93.7
94.9
95.4
0.83
550
5.8
1.9
360
483
315
Δ
45.6
3821
93.8
95.1
95.6
0.84
590
5.8
1.8
1LP1222-3AC55-8■■■
395
530
315
Δ
45.7
4193
93.8
95.1
95.6
0.85
640
5.5
1.7
1LP1222-3AC75-8■■■
500
671
355
Δ
45.5
5307
93.9
95.1
95.5
0.87
790
6.3
1.9
1LP1222-3BC55-8■■■
575
771
355
Δ
45.5
6102
94.1
95.3
95.6
0.87
910
6.6
1.6
1LP1222-3BC75-8■■■
For versions, see Article No. supplements and special versions
1LP1222-3AC75-8■■■
9/14
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency – low noise
Motor type
mIM B3
mIM V1
J
LpfA,
LWA,
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
tolerance
+3 dB(A)
no-load
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LP1212-3AB15-5...
1LP1212-3AB35-5...
1LP1212-3AB55-5...
1LP1212-3AB75-5...
1280
1470
1640
1800
1330
1520
1690
1850
3.3
4.2
4.8
5.7
79
79
79
79
94.5
94.5
94.5
94.5
3600
3600
3600
3600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
590
725
725
820
1LP1212-3BB55-1...
1LP1212-3BB75-1...
2260
2380
2310
2440
8.0
8.7
79
79
95
95
3300
3300
1XB7 740
6SL3710-7LE41-0AA3
2 x 1XB7 740 6SL3710-7LE41-2AA3
960
1230
1LP1212-3AB15-6...
1LP1212-3AB35-6...
1LP1212-3AB55-6...
1LP1212-3AB75-6...
1LP1212-3BB55-6...
1LP1212-3BB75-6...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
6SL3710-7LE41-2AA3
590
725
725
960
1230
1230
1LP1212-3AC15-7...
1LP1212-3AC35-7...
1LP1212-3AC55-7...
1LP1212-3AC75-7...
1LP1212-3BC55-7...
1LP1212-3BC75-7...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE37-5AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
477
590
725
725
960
1230
1LP1212-3AC15-8...
1LP1212-3AC35-8...
1LP1212-3AC55-8...
1LP1212-3AC75-8...
1LP1212-3BC55-8...
1LP1212-3BC75-8...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
477
590
590
590
725
820
1LP1222-3AB15-5...
1LP1222-3AB35-5...
1LP1222-3AB55-5...
1LP1222-3AB75-5...
1280
1470
1640
1800
1330
1520
1690
1850
3.3
4.2
4.8
5.7
79
79
79
79
94.5
94.5
94.5
94.5
3600
3600
3600
3600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
590
725
820
960
1LP1222-3BB55-1...
1LP1222-3BB75-1...
2260
2380
2310
2440
8.0
8.7
79
79
95
95
3300
3300
2 x 1XB7 740 6SL3710-2GE41-1AA3
2 x 1XB7 740 6SL3710-2GE41-1AA3
1092
1092
1LP1222-3AB15-6...
1LP1222-3AB35-6...
1LP1222-3AB55-6...
1LP1222-3AB75-6...
1LP1222-3BB55-6...
1LP1222-3BB75-6...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-4AA3
6SL3710-2GE41-4AA3
590
725
820
960
1340
1340
1LP1222-3AC15-7...
1LP1222-3AC35-7...
1LP1222-3AC55-7...
1LP1222-3AC75-7...
1LP1222-3BC55-7...
1LP1222-3BC75-7...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-1AA3
590
725
725
820
1092
1092
1LP1222-3AC15-8...
1LP1222-3AC35-8...
1LP1222-3AC55-8...
1LP1222-3AC75-8...
1LP1222-3BC55-8...
1LP1222-3BC75-8...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE35-0AA3
6SL3710-1GE36-1AA3
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
477
590
590
725
820
960
Siemens D 81.8 · 04/2014
9
9/15
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency – increased output
■ Selection and ordering data
Prated
9
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
T B/
Trated
1LP1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 480 V
3600 rpm, 4-pole
415
557
315
Δ
120.8
1102
95.0
95.7
95.5
0.88
590
5.0
1.7
1LP1312-3AB15-5■■■
525
704
316
Δ
120.8
1393
95.5
96.1
95.9
0.89
740
5.7
1.9
1LP1312-3AB35-5■■■
1LP1312-3AB55-5■■■
540
724
317
Δ
120.9
1434
95.4
96.1
96.0
0.89
760
5.0
1.6
620
831
318
Δ
120.8
1646
95.6
96.3
96.2
0.90
860
5.4
1.7
1LP1312-3AB75-5■■■
3000 rpm, 4-pole
705
945
355
Δ
100.9
2245
95.2
96.2
96.4
0.87
1020
3.8
1.4
1LP1312-3BB55-1■■■
810
1086
355
Δ
100.8
2579
95.6
96.5
96.6
0.88
1140
4.4
1.6
1LP1312-3BB75-1■■■
1800 rpm, 4-pole
405
543
315
Δ
60.7
2149
94.4
95.6
95.9
0.88
580
5.5
2.0
1LP1312-3AB15-6■■■
1LP1312-3AB35-6■■■
495
664
316
Δ
60.7
2627
94.6
95.7
96.1
0.89
700
5.7
2.0
550
738
317
Δ
60.7
2919
94.8
95.9
96.3
0.90
770
5.8
2.0
1LP1312-3AB55-6■■■
1LP1312-3AB75-6■■■
705
945
318
Δ
60.6
3741
95.3
96.3
96.6
0.90
980
6.9
2.0
840
1126
355
Δ
60.6
4457
95.3
96.3
96.6
0.89
1180
5.5
2.0
1LP1312-3BB55-6■■■
1LP1312-3BB75-6■■■
850
1140
355
Δ
60.7
4511
95.1
96.3
96.6
0.89
1200
5.0
1.9
1200 rpm, 6-pole
340
456
315
Δ
60.8
2708
93.8
95.2
95.7
0.82
520
5.2
1.6
1LP1312-3AC15-7■■■
1LP1312-3AC35-7■■■
415
557
316
Δ
60.7
3305
94.1
95.4
95.9
0.84
620
5.4
1.6
495
664
317
Δ
60.7
3941
94.6
95.8
96.1
0.84
740
5.8
1.8
1LP1312-3AC55-7■■■
1LP1312-3AC75-7■■■
525
704
318
Δ
60.7
4180
94.6
95.7
96.1
0.85
780
5.7
1.7
650
872
355
Δ
60.5
5174
94.9
95.9
96.1
0.86
950
6.8
1.9
1LP1312-3BC55-7■■■
710
952
355
Δ
60.5
5651
95.0
96.0
96.1
0.87
1020
6.8
1.8
1LP1312-3BC75-7■■■
900 rpm, 6-pole
295
396
315
Δ
45.8
3131
92.8
94.3
95.0
0.82
460
5.1
1.6
1LP1312-3AC15-8■■■
1LP1312-3AC35-8■■■
370
496
316
Δ
45.7
3926
93.4
94.8
95.3
0.82
570
5.6
1.8
395
530
317
Δ
45.7
4195
93.1
94.6
95.3
0.85
590
5.1
1.6
1LP1312-3AC55-8■■■
435
583
318
Δ
45.7
4618
93.3
94.8
95.4
0.85
650
5.2
1.6
1LP1312-3AC75-8■■■
1LP1312-3BC55-8■■■
505
677
355
Δ
45.6
5360
93.6
94.9
95.4
0.87
740
5.7
1.8
570
764
355
Δ
45.6
6049
93.8
95.1
95.5
0.88
820
6.0
1.6
1LP1312-3BC75-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 440 V
3600 rpm, 4-pole
425
570
315
Δ
120.8
1128
95.1
95.7
95.5
0.88
660
5.2
1.7
1LP1322-3AB15-5■■■
1LP1322-3AB35-5■■■
495
664
316
Δ
120.9
1314
95.3
96.0
95.8
0.89
760
5.0
1.6
560
751
317
Δ
120.8
1486
95.6
96.2
96.0
0.90
850
5.6
1.8
1LP1322-3AB55-5■■■
650
872
318
Δ
120.7
1725
95.8
96.4
96.2
0.91
970
6.3
2.0
1LP1322-3AB75-5■■■
3000 rpm, 4-pole
735
986
355
Δ
100.8
2340
95.5
96.4
96.5
0.88
1140
4.2
1.5
1LP1322-3BB55-1■■■
745
999
355
Δ
100.9
2372
95.3
96.3
96.5
0.88
1160
3.9
1.4
1LP1322-3BB75-1■■■
1800 rpm, 4-pole
400
536
315
Δ
60.7
2123
94.4
95.6
95.9
0.88
620
5.7
2.0
1LP1322-3AB15-6■■■
500
671
316
Δ
60.7
2654
94.7
95.8
96.2
0.89
770
5.8
2.0
1LP1322-3AB35-6■■■
565
758
317
Δ
60.7
2999
94.9
96.0
96.3
0.90
860
6.0
2.1
1LP1322-3AB55-6■■■
650
872
318
Δ
60.7
3449
95.0
96.1
96.4
0.91
980
6.2
2.1
1LP1322-3AB75-6■■■
770
1033
355
Δ
60.7
4087
95.0
96.2
96.6
0.89
1180
5.0
1.8
1LP1322-3BB55-6■■■
895
1200
355
Δ
60.6
4749
95.4
96.4
96.7
0.89
1360
5.6
2.1
1LP1322-3BB75-6■■■
1200 rpm, 6-pole
360
483
315
Δ
60.7
2866
94.3
95.4
95.8
0.82
600
5.7
1.7
1LP1322-3AC15-7■■■
425
570
316
Δ
60.7
3385
94.3
95.5
95.9
0.83
700
5.6
1.7
1LP1322-3AC35-7■■■
480
644
317
Δ
60.7
3822
94.5
95.7
96.0
0.84
780
5.7
1.7
1LP1322-3AC55-7■■■
535
717
318
Δ
60.7
4261
94.6
95.8
96.1
0.85
860
5.5
1.7
1LP1322-3AC75-7■■■
635
852
355
Δ
60.5
5054
94.9
96.0
96.1
0.86
1000
6.9
2.0
1LP1322-3BC55-7■■■
710
952
355
Δ
60.5
5652
95.0
96.0
96.2
0.87
1120
6.7
1.8
1LP1322-3BC75-7■■■
900 rpm, 6-pole
290
389
315
Δ
45.7
3077
92.9
94.4
95.0
0.81
500
5.4
1.8
1LP1322-3AC15-8■■■
1LP1322-3AC35-8■■■
360
483
316
Δ
45.7
3821
93.1
94.6
95.2
0.83
600
5.3
1.7
395
530
317
Δ
45.7
4193
93.2
94.7
95.3
0.84
650
5.3
1.7
1LP1322-3AC55-8■■■
430
577
318
Δ
45.7
4567
93.2
94.7
95.4
0.85
700
5.0
1.6
1LP1322-3AC75-8■■■
515
691
355
Δ
45.6
5466
93.7
95.0
95.5
0.87
820
6.0
1.8
1LP1322-3BC55-8■■■
595
798
355
Δ
45.5
6315
94.0
95.2
95.6
0.87
940
6.4
1.6
1LP1322-3BC75-8■■■
For versions, see Article No. supplements and special versions
1LP1222-3AC75-8■■■
9/16
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 460 V, 60 Hz
High Efficiency – increased output
Motor type
mIM B3
mIM V1
J
LpfA,
LWA,
Terminal box
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
tolerance
+3 dB(A)
no-load
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LP1312-3AB15-5...
1LP1312-3AB35-5...
1LP1312-3AB55-5...
1LP1312-3AB75-5...
1280
1470
1640
1800
1330
1520
1690
1850
3.3
4.2
4.8
5.7
85
85
85
85
100.5
100.5
100.5
100.5
3600
3600
3600
3600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE38-4AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
590
820
820
960
1LP1312-3BB55-1...
1LP1312-3BB75-1...
2260
2380
2310
2440
8.0
8.7
85
85
101
101
3300
3300
1XB7 740
6SL3710-7LE41-2AA3
2 x 1XB7 740 6SL3710-7LE41-2AA3
1230
1230
1LP1312-3AB15-6...
1LP1312-3AB35-6...
1LP1312-3AB55-6...
1LP1312-3AB75-6...
1LP1312-3BB55-6...
1LP1312-3BB75-6...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-2AA3
6SL3710-7LE41-2AA3
6SL3710-7LE41-2AA3
590
725
820
1230
1230
1230
1LP1312-3AC15-7...
1LP1312-3AC35-7...
1LP1312-3AC55-7...
1LP1312-3AC75-7...
1LP1312-3BC55-7...
1LP1312-3BC75-7...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE38-4AA3
6SL3710-7LE41-0AA3
6SL3710-7LE41-2AA3
590
725
820
820
960
1230
1LP1312-3AC15-8...
1LP1312-3AC35-8...
1LP1312-3AC55-8...
1LP1312-3AC75-8...
1LP1312-3BC55-8...
1LP1312-3BC75-8...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LE35-0AA3
6SL3710-7LE36-1AA3
6SL3710-7LE36-1AA3
6SL3710-7LE37-5AA3
6SL3710-7LE38-4AA3
6SL3710-7LE38-4AA3
477
590
590
725
820
820
1LP1322-3AB15-5...
1LP1322-3AB35-5...
1LP1322-3AB55-5...
1LP1322-3AB75-5...
1280
1470
1640
1800
1330
1520
1690
1850
3.3
4.2
4.8
5.7
85
85
85
85
100.5
100.5
100.5
100.5
3600
3600
3600
3600
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
725
820
960
1092
1LP1322-3BB55-1...
1LP1322-3BB75-1...
2260
2380
2310
2440
8.0
8.7
85
85
101
101
3300
3300
2 x 1XB7 740 6SL3710-2GE41-4AA3
2 x 1XB7 740 6SL3710-2GE41-4AA3
1340
1340
1LP1322-3AB15-6...
1LP1322-3AB35-6...
1LP1322-3AB55-6...
1LP1322-3AB75-6...
1LP1322-3BB55-6...
1LP1322-3BB75-6...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
2 x 1XB7 740
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-6AA3
6SL3710-2GE41-6AA3
725
820
960
1092
1340
1516
1LP1322-3AC15-7...
1LP1322-3AC35-7...
1LP1322-3AC55-7...
1LP1322-3AC75-7...
1LP1322-3BC55-7...
1LP1322-3BC75-7...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
2 x 1XB7 740
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
6SL3710-2GE41-1AA3
6SL3710-2GE41-4AA3
725
725
820
960
1092
1340
1LP1322-3AC15-8...
1LP1322-3AC35-8...
1LP1322-3AC55-8...
1LP1322-3AC75-8...
1LP1322-3BC55-8...
1LP1322-3BC75-8...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GE36-1AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE37-5AA3
6SL3710-1GE38-4AA3
6SL3710-1GE41-0AA3
590
725
725
725
820
960
Siemens D 81.8 · 04/2014
9
9/17
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency – low noise
■ Selection and ordering data
Prated
9
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
T B/
Trated
1LP1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V
3600 rpm, 4-pole
340
456
315
Δ
120.8
902
95.0
95.5
95.1
0.88
385
5.5
1.8
1LP1212-3AB16-5■■■
440
590
315
Δ
120.6
1168
95.5
96.0
95.6
0.90
480
6.7
2.2
1LP1212-3AB36-5■■■
1LP1212-3AB56-5■■■
480
644
315
Δ
120.6
1274
95.7
96.2
95.8
0.90
520
7.1
2.3
550
738
315
Δ
120.6
1459
95.8
96.3
96.0
0.91
590
7.4
2.3
1LP1212-3AB76-5■■■
3000 rpm, 4-pole
635
852
355
Δ
100.9
2022
95.2
96.2
96.3
0.88
710
4.2
1.5
1LP1212-3BB56-1■■■
720
966
355
Δ
100.8
2292
95.4
96.4
96.4
0.89
790
4.5
1.6
1LP1212-3BB76-1■■■
1800 rpm, 4-pole
325
436
315
Δ
60.6
1725
94.7
95.7
96.0
0.88
365
6.3
2.2
1LP1212-3AB16-6■■■
1LP1212-3AB36-6■■■
430
577
315
Δ
60.6
2282
95.2
96.1
96.3
0.88
480
7.4
2.6
465
624
315
Δ
60.6
2468
95.3
96.2
96.4
0.90
510
7.4
2.6
1LP1212-3AB56-6■■■
1LP1212-3AB76-6■■■
570
764
315
Δ
60.5
3024
95.6
96.5
96.6
0.89
630
8.2
2.4
760
1019
355
Δ
60.6
4034
95.3
96.3
96.6
0.89
840
5.9
2.2
1LP1212-3BB56-6■■■
1LP1212-3BB76-6■■■
845
1133
355
Δ
60.5
4484
95.5
96.5
96.7
0.89
930
6.4
2.2
1200 rpm, 6-pole
295
396
315
Δ
60.6
2348
94.5
95.5
95.8
0.82
355
6.5
2.0
1LP1212-3AC16-7■■■
1LP1212-3AC36-7■■■
365
489
315
Δ
60.6
2907
94.7
95.7
96.0
0.83
435
6.5
2.0
395
530
315
Δ
60.6
3147
94.8
95.8
96.1
0.84
465
6.4
2.0
1LP1212-3AC56-7■■■
1LP1212-3AC76-7■■■
440
590
315
Δ
60.6
3504
94.9
95.9
96.2
0.85
510
6.6
2.0
590
791
355
Δ
60.4
4697
95.1
96.0
96.0
0.86
680
8.0
2.1
1LP1212-3BC56-7■■■
650
872
355
Δ
60.5
5176
95.0
96.0
96.1
0.87
740
7.6
1.9
1LP1212-3BC76-7■■■
900 rpm, 6-pole
240
322
315
Y
45.6
2549
93.2
94.5
95.0
0.81
295
6.0
1.9
1LP1212-3AC16-8■■■
1LP1212-3AC36-8■■■
320
429
315
Δ
45.6
3397
93.8
95.0
95.4
0.82
390
6.3
2.0
335
449
315
Δ
45.6
3557
93.8
95.1
95.5
0.84
395
6.2
2.0
1LP1212-3AC56-8■■■
375
503
315
Δ
45.6
3981
94.0
95.2
95.6
0.84
445
6.5
1.9
1LP1212-3AC76-8■■■
1LP1212-3BC56-8■■■
470
630
355
Δ
45.5
4987
93.8
95.1
95.4
0.87
540
6.7
2.0
525
704
355
Δ
45.5
5572
93.9
95.2
95.5
0.87
600
6.7
1.8
1LP1212-3BC76-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V
3600 rpm, 4-pole
345
463
315
Δ
120.6
916
95.2
95.6
95.2
0.89
425
6.6
2.2
1LP1222-3AB16-5■■■
1LP1222-3AB36-5■■■
420
563
315
Δ
120.6
1114
95.5
96.0
95.5
0.90
510
7.2
2.4
465
624
315
Δ
120.5
1234
95.7
96.1
95.7
0.90
560
7.8
2.5
1LP1222-3AB56-5■■■
505
677
315
Δ
120.7
1340
95.7
96.2
95.9
0.91
610
6.4
2.1
1LP1222-3AB76-5■■■
3000 rpm, 4-pole
640
858
355
Δ
100.8
2038
95.3
96.2
96.3
0.88
790
4.3
1.5
1LP1222-3BB56-1■■■
720
966
355
Δ
100.8
2293
95.5
96.4
96.4
0.89
880
4.8
1.7
1LP1222-3BB76-1■■■
1800 rpm, 4-pole
315
422
315
Δ
60.7
1672
94.6
95.6
95.9
0.88
395
6.0
2.1
1LP1222-3AB16-6■■■
415
557
315
Δ
60.6
2202
95.2
96.1
96.2
0.89
510
7.4
2.6
1LP1222-3AB36-6■■■
460
617
315
Δ
60.6
2441
95.3
96.2
96.4
0.90
560
7.4
2.5
1LP1222-3AB56-6■■■
570
764
315
Δ
60.5
3025
95.7
96.5
96.6
0.89
700
8.4
2.4
1LP1222-3AB76-6■■■
760
1019
355
Δ
60.6
4033
95.3
96.4
96.6
0.89
930
6.1
2.3
1LP1222-3BB56-6■■■
775
1039
355
Δ
60.6
4113
95.2
96.3
96.6
0.89
950
5.5
2.1
1LP1222-3BB76-6■■■
1200 rpm, 6-pole
280
375
315
Δ
60.7
2229
94.1
95.3
95.7
0.83
370
6.0
1.8
1LP1222-3AC16-7■■■
360
483
315
Δ
60.6
2868
94.7
95.7
96.0
0.83
475
6.5
2.0
1LP1222-3AC36-7■■■
395
530
315
Δ
60.6
3146
94.8
95.8
96.1
0.84
520
6.4
2.0
1LP1222-3AC56-7■■■
445
597
315
Δ
60.6
3544
94.9
96.0
96.2
0.85
570
6.8
2.0
1LP1222-3AC76-7■■■
570
764
355
Δ
60.5
4539
95.0
95.9
96.0
0.86
730
7.6
2.2
1LP1222-3BC56-7■■■
650
872
355
Δ
60.4
5175
95.2
96.0
96.0
0.86
830
8.2
1.9
1LP1222-3BC76-7■■■
900 rpm, 6-pole
245
329
315
Δ
45.6
2602
93.4
94.6
95.1
0.80
340
6.3
2.1
1LP1222-3AC16-8■■■
1LP1222-3AC36-8■■■
310
416
315
Δ
45.6
3293
93.7
95.0
95.3
0.81
425
6.5
2.1
340
456
315
Δ
45.6
3611
93.8
95.1
95.5
0.83
450
6.4
2.0
1LP1222-3AC56-8■■■
375
503
315
Δ
45.6
3981
94.0
95.2
95.6
0.84
490
6.5
1.9
1LP1222-3AC76-8■■■
465
624
355
Δ
45.5
4935
93.8
95.1
95.4
0.87
590
6.7
2.0
1LP1222-3BC56-8■■■
520
697
355
Δ
45.5
5518
93.9
95.1
95.5
0.87
660
6.8
1.8
1LP1222-3BC76-8■■■
For versions, see Article No. supplements and special versions
1LP1222-3AC76-8■■■
9/18
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency – low noise
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LP1212-3AB16-5...
1LP1212-3AB36-5...
1LP1212-3AB56-5...
1LP1212-3AB76-5...
1280
1470
1640
1800
1330
1520
1690
1850
3.3
4.2
4.8
5.7
79
79
79
79
94.5
94.5
94.5
94.5
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 731
1XB7 731
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
400
560
560
710
1LP1212-3BB56-1...
1LP1212-3BB76-1...
2260
2380
2310
2440
8.0
8.7
79
79
95
95
3300
3300
1XB7 740
1XB7 740
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
710
790
1LP1212-3AB16-6...
1LP1212-3AB36-6...
1LP1212-3AB56-6...
1LP1212-3AB76-6...
1LP1212-3BB56-6...
1LP1212-3BB76-6...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-8AA3
6SL3710-7LG41-0AA3
400
560
560
710
880
1000
1LP1212-3AC16-7...
1LP1212-3AC36-7...
1LP1212-3AC56-7...
1LP1212-3AC76-7...
1LP1212-3BC56-7...
1LP1212-3BC76-7...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
400
452
560
560
710
790
1LP1212-3AC16-8...
1LP1212-3AC36-8...
1LP1212-3AC56-8...
1LP1212-3AC76-8...
1LP1212-3BC56-8...
1LP1212-3BC76-8...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-7LG33-3AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-1AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
320
400
400
452
560
710
1LP1222-3AB16-5...
1LP1222-3AB36-5...
1LP1222-3AB56-5...
1LP1222-3AB76-5...
1280
1470
1640
1800
1330
1520
1690
1850
3.3
4.2
4.8
5.7
79
79
79
79
94.5
94.5
94.5
94.5
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
452
560
560
710
1LP1222-3BB56-1...
1LP1222-3BB76-1...
2260
2380
2310
2440
8.0
8.7
79
79
95
95
3300
3300
1XB7 740
1XB7 740
6SL3710-1GF38-1AA3
6SL3710-2GF41-1AA3
790
1036
1LP1222-3AB16-6...
1LP1222-3AB36-6...
1LP1222-3AB56-6...
1LP1222-3AB76-6...
1LP1222-3BB56-6...
1LP1222-3BB76-6...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GF34-1AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-2GF41-1AA3
6SL3710-2GF41-1AA3
400
560
560
710
1036
1036
1LP1222-3AC16-7...
1LP1222-3AC36-7...
1LP1222-3AC56-7...
1LP1222-3AC76-7...
1LP1222-3BC56-7...
1LP1222-3BC76-7...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GF34-1AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF38-1AA3
6SL3710-2GF38-6AA3
400
560
560
710
790
836
1LP1222-3AC16-8...
1LP1222-3AC36-8...
1LP1222-3AC56-8...
1LP1222-3AC76-8...
1LP1222-3BC56-8...
1LP1222-3BC76-8...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
79
79
79
79
79
79
94.5
94.5
94.5
94.5
95
95
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
400
452
452
560
710
710
Siemens D 81.8 · 04/2014
9
9/19
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency – increased output
■ Selection and ordering data
Prated
9
Prated
Operating values at rated output
Frame Con- frated
Trated
ηrated, ηrated,
size
nec5/4
4/4
tion
ηrated,
cosϕrated, Irated
3/4
4/4
ILR/
Irated
T B/
Trated
1LP1 cast-iron series
specially designed for
converter-fed operation
kW
hp
FS
Hz
Nm
%
%
%
A
Article No.
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with regulated infeed – SINAMICS S120 (ALM), SINAMICS S150; rated voltage 610 V
3600 rpm, 4-pole
385
516
315
Δ
120.9
1022
94.7
95.4
95.3
0.88
435
4.8
1.6
1LP1312-3AB16-5■■■
505
677
316
Δ
120.7
1340
95.4
96.0
95.8
0.89
560
5.8
1.9
1LP1312-3AB36-5■■■
1LP1312-3AB56-5■■■
560
751
317
Δ
120.7
1486
95.5
96.1
95.9
0.90
610
6.1
2.0
640
858
318
Δ
120.7
1699
95.7
96.3
96.1
0.91
690
6.3
2.0
1LP1312-3AB76-5■■■
3000 rpm, 4-pole
680
912
355
Δ
100.9
2165
95.0
96.1
96.3
0.87
770
3.8
1.4
1LP1312-3BB56-1■■■
760
1019
355
Δ
100.9
2420
95.3
96.3
96.4
0.88
850
4.2
1.5
1LP1312-3BB76-1■■■
1800 rpm, 4-pole
355
476
315
Δ
60.7
1885
94.2
95.4
95.8
0.88
400
5.7
2.0
1LP1312-3AB16-6■■■
1LP1312-3AB36-6■■■
485
650
316
Δ
60.6
2574
94.8
95.9
96.1
0.89
540
6.6
2.3
530
711
317
Δ
60.6
2813
94.9
95.9
96.3
0.90
580
6.5
2.2
1LP1312-3AB56-6■■■
1LP1312-3AB76-6■■■
655
878
318
Δ
60.6
3476
95.2
96.2
96.5
0.90
720
7.2
2.1
800
1073
355
Δ
60.6
4245
95.1
96.2
96.5
0.89
880
5.6
2.1
1LP1312-3BB56-6■■■
1LP1312-3BB76-6■■■
895
1200
355
Δ
60.6
4750
95.3
96.4
96.6
0.89
990
6.0
2.1
1200 rpm, 6-pole
325
436
315
Δ
60.7
2587
94.0
95.2
95.6
0.82
395
5.8
1.8
1LP1312-3AC16-7■■■
1LP1312-3AC36-7■■■
400
536
316
Δ
60.7
3184
94.3
95.4
95.8
0.83
480
5.9
1.8
440
590
317
Δ
60.7
3504
94.3
95.5
95.9
0.84
520
5.7
1.7
1LP1312-3AC56-7■■■
1LP1312-3AC76-7■■■
485
650
318
Δ
60.6
3861
94.5
95.6
96.0
0.85
560
6.0
1.8
615
825
355
Δ
60.5
4897
95.0
95.9
96.0
0.86
710
7.7
2.0
1LP1312-3BC56-7■■■
675
905
355
Δ
60.5
5374
94.9
95.9
96.0
0.87
770
7.3
1.8
1LP1312-3BC76-7■■■
900 rpm, 6-pole
260
349
315
Y
45.7
2759
92.6
94.1
94.8
0.82
320
5.5
1.8
1LP1312-3AC16-8■■■
1LP1312-3AC36-8■■■
350
469
316
Δ
45.7
3714
93.3
94.6
95.2
0.82
425
5.8
1.9
375
503
317
Δ
45.7
3981
93.2
94.6
95.3
0.84
445
5.5
1.8
1LP1312-3AC56-8■■■
415
557
318
Δ
45.6
4407
93.5
94.8
95.3
0.84
495
5.9
1.7
1LP1312-3AC76-8■■■
1LP1312-3BC56-8■■■
485
650
355
Δ
45.5
5148
93.7
95.0
95.4
0.87
560
6.5
1.9
545
731
355
Δ
45.5
5784
93.8
95.1
95.5
0.87
620
6.5
1.7
1LP1312-3BC76-8■■■
• Insulation: thermal class 180 (temperature class H), IP54/IP55 degree of protection, utilization in accordance with thermal class 155 (temperature class F)
• Converter-fed operation with unregulated infeed – SINAMICS G130, SINAMICS G150, SINAMICS S120 (BLM, SLM); rated voltage 550 V
3600 rpm, 4-pole
400
536
315
Δ
120.8
1062
95.1
95.6
95.4
0.88
500
5.6
1.9
1LP1322-3AB16-5■■■
1LP1322-3AB36-5■■■
490
657
316
Δ
120.7
1300
95.4
96.0
95.7
0.90
600
6.1
2.0
550
738
317
Δ
120.7
1460
95.6
96.2
95.9
0.90
670
6.5
2.1
1LP1322-3AB56-5■■■
585
784
318
Δ
120.8
1553
95.5
96.2
96.0
0.90
710
5.5
1.8
1LP1322-3AB76-5■■■
3000 rpm, 4-pole
670
898
355
Δ
100.9
2133
95.1
96.2
96.3
0.88
830
4.1
1.5
1LP1322-3BB56-1■■■
765
1026
355
Δ
100.8
2438
95.4
96.4
96.4
0.89
940
4.5
1.6
1LP1322-3BB76-1■■■
1800 rpm, 4-pole
340
456
315
Δ
60.7
1804
94.2
95.4
95.8
0.88
425
5.6
2.0
1LP1322-3AB16-6■■■
470
630
316
Δ
60.6
2495
94.7
95.8
96.1
0.89
580
6.5
2.3
1LP1322-3AB36-6■■■
525
704
317
Δ
60.7
2786
94.8
95.9
96.3
0.90
640
6.4
2.2
1LP1322-3AB56-6■■■
655
878
318
Δ
60.6
3475
95.3
96.2
96.5
0.90
790
7.5
2.1
1LP1322-3AB76-6■■■
805
1080
355
Δ
60.6
4272
95.2
96.3
96.6
0.89
990
5.7
2.1
1LP1322-3BB56-6■■■
820
1100
355
Δ
60.7
4352
95.0
96.2
96.5
0.89
1000
5.3
2.0
1LP1322-3BB76-6■■■
1200 rpm, 6-pole
300
402
315
Δ
60.7
2389
93.7
95.0
95.5
0.83
400
5.5
1.7
1LP1322-3AC16-7■■■
395
530
316
Δ
60.7
3145
94.2
95.4
95.8
0.83
520
6.0
1.8
1LP1322-3AC36-7■■■
435
583
317
Δ
60.7
3464
94.3
95.5
95.9
0.84
570
5.8
1.8
1LP1322-3AC56-7■■■
490
657
318
Δ
60.6
3901
94.5
95.7
96.0
0.85
630
6.1
1.8
1LP1322-3AC76-7■■■
590
791
355
Δ
60.5
4698
94.9
95.9
96.0
0.86
750
7.4
2.1
1LP1322-3BC56-7■■■
675
905
355
Δ
60.4
5374
95.1
96.0
96.0
0.86
860
7.9
1.8
1LP1322-3BC76-7■■■
900 rpm, 6-pole
270
362
315
Δ
45.7
2865
92.8
94.2
94.8
0.81
370
5.8
1.9
1LP1322-3AC16-8■■■
1LP1322-3AC36-8■■■
330
443
316
Δ
45.6
3504
93.4
94.7
95.1
0.82
445
6.2
2.0
375
503
317
Δ
45.6
3980
93.3
94.6
95.2
0.84
495
5.8
1.8
1LP1322-3AC56-8■■■
410
550
318
Δ
45.6
4353
93.4
94.8
95.3
0.84
540
5.9
1.7
1LP1322-3AC76-8■■■
480
644
355
Δ
45.5
5094
93.7
95.0
95.4
0.87
610
6.5
1.9
1LP1322-3BC56-8■■■
540
724
355
Δ
45.5
5731
93.8
95.1
95.4
0.87
690
6.5
1.7
1LP1322-3BC76-8■■■
For versions, see Article No. supplements and special versions
1LP1222-3AC76-8■■■
9/20
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Forced-air cooled motors — open version
1LP1 motors for converter-fed operation
Line voltage 575 V, 60 Hz
High Efficiency – increased output
Motor type
mIM B3
mIM V1
J
tolerance
+3 dB(A)
no-load
Mech.
speed
limit
IM B3
Terminal
box
Preferred SINAMICS
converter –
Base-load
other SINAMICS converters current
IL
also possible
LpfA,
LWA,
tolerance
+3 dB(A)
no-load
kg
kg
kgm2
dB(A)
dB(A)
rpm
Type
Type
A
1LP1312-3AB16-5...
1LP1312-3AB36-5...
1LP1312-3AB56-5...
1LP1312-3AB76-5...
1280
1470
1640
1800
1330
1520
1690
1850
3.3
4.2
4.8
5.7
85
85
85
85
100.5
100.5
100.5
100.5
3600
3600
3600
3600
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG37-4AA3
452
560
710
710
1LP1312-3BB56-1...
1LP1312-3BB76-1...
2260
2380
2310
2440
8.0
8.7
85
85
101
101
3300
3300
1XB7 740
1XB7 740
6SL3710-7LG38-1AA3
6SL3710-7LG38-8AA3
790
880
1LP1312-3AB16-6...
1LP1312-3AB36-6...
1LP1312-3AB56-6...
1LP1312-3AB76-6...
1LP1312-3BB56-6...
1LP1312-3BB76-6...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
6SL3710-7LG38-8AA3
6SL3710-7LG41-0AA3
400
560
710
790
880
1000
1LP1312-3AC16-7...
1LP1312-3AC36-7...
1LP1312-3AC56-7...
1LP1312-3AC76-7...
1LP1312-3BC56-7...
1LP1312-3BC76-7...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-7LG34-1AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
6SL3710-7LG38-1AA3
400
560
560
560
710
790
1LP1312-3AC16-8...
1LP1312-3AC36-8...
1LP1312-3AC56-8...
1LP1312-3AC76-8...
1LP1312-3BC56-8...
1LP1312-3BC76-8...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 730
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
6SL3710-7LG33-3AA3
6SL3710-7LG34-7AA3
6SL3710-7LG34-7AA3
6SL3710-7LG35-8AA3
6SL3710-7LG35-8AA3
6SL3710-7LG37-4AA3
320
452
452
560
560
710
1LP1322-3AB16-5...
1LP1322-3AB36-5...
1LP1322-3AB56-5...
1LP1322-3AB76-5...
1280
1470
1640
1800
1330
1520
1690
1850
3.3
4.2
4.8
5.7
85
85
85
85
100.5
100.5
100.5
100.5
3600
3600
3600
3600
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
560
710
710
710
1LP1322-3BB56-1...
1LP1322-3BB76-1...
2260
2380
2310
2440
8.0
8.7
85
85
101
101
3300
3300
1XB7 740
1XB7 740
6SL3710-2GF38-6AA3
6SL3710-2GF41-1AA3
836
1036
1LP1322-3AB16-6...
1LP1322-3AB36-6...
1LP1322-3AB56-6...
1LP1322-3AB76-6...
1LP1322-3BB56-6...
1LP1322-3BB76-6...
1280
1470
1640
1800
2260
2380
1330
1520
1690
1850
2310
2440
3.3
4.2
4.8
5.7
8.0
8.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
3000
3000
3000
3000
2600
2600
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GF34-7AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
6SL3710-1GF38-1AA3
6SL3710-2GF41-1AA3
6SL3710-2GF41-1AA3
452
710
710
790
1036
1036
1LP1322-3AC16-7...
1LP1322-3AC36-7...
1LP1322-3AC56-7...
1LP1322-3AC76-7...
1LP1322-3BC56-7...
1LP1322-3BC76-7...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
1XB7 740
6SL3710-1GF34-1AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
6SL3710-1GF38-1AA3
6SL3710-2GF41-1AA3
400
560
710
710
790
1036
1LP1322-3AC16-8...
1LP1322-3AC36-8...
1LP1322-3AC56-8...
1LP1322-3AC76-8...
1LP1322-3BC56-8...
1LP1322-3BC76-8...
1310
1490
1670
1780
2250
2400
1360
1540
1720
1830
2310
2450
5.7
7.0
8.1
8.9
14.3
15.7
85
85
85
85
85
85
100.5
100.5
100.5
100.5
101
101
2600
2600
2600
2600
2500
2500
1XB7 731
1XB7 731
1XB7 731
1XB7 731
1XB7 740
1XB7 740
6SL3710-1GF34-1AA3
6SL3710-1GF34-7AA3
6SL3710-1GF35-8AA3
6SL3710-1GF35-8AA3
6SL3710-1GF37-4AA3
6SL3710-1GF37-4AA3
400
452
560
560
710
710
Siemens D 81.8 · 04/2014
9
9/21
© Siemens AG 2014
Forced-air cooled motors — open version
Dimensions
1LP1 motors
Radially mounted equipment unit
■ Dimensional drawings
IM B3 type of construction
For terminal box dimensions, see Page 9/25
HC
L
HB'
HK
LL
BE
HD
ØD
F
HB
AC
AG
AD
BC
GA
H
HA
EB
DB
BA
E
G_D081_XX_00424
C
B
BB
ØK
Ø K'
AA
A
AB
IM B35 and IM V1 types of construction
For flange dimensions, see Page 9/24 (Z = the number of retaining holes),
for terminal box dimensions, see Page 9/25
L
HC
LM
HB'
LL
HK
HH
T
HB
ØP
ØN
ØD
F
HD
AC
ZxS
E
GA
AD
BE
AG
9
M
H
HA
EB
DB
G_D081_XX_00425
BA
LA
LE
C
ØK
Ø K'
B
BB
AA
A
AB
Frame No. of
size
poles
Motor type
315
1LP12..-3A.1.-....
560 120 680 1155 630 180 780 180 315 28
1LP12..-3A.3.-.... ● 560 120 680 1155 630 180 780 200 315 28
28 35 1450 1670 85
M20 170 140 22 90
28 35 1470 1690 95
M24 170 140 25 100
1LP12..-3A.5.-....
560 120 680 1155 835 180 985 180 315 28
1LP12..-3A.7.-.... ● 560 120 680 1155 835 180 985 200 315 28
28 35 1590 1810 85
M20 170 140 22 90
28 35 1610 1830 95
M24 170 140 25 100
1LP13.-3A.1.-….
560 120 680 1245 630 180 780 180 315 28
1LP13.-3A.3.-…. ● 560 120 680 1245 630 180 780 200 315 28
28 35 1450 1765 85
M20 170 140 22 90
28 35 1470 1785 95
M24 170 140 25 100
1LP13.-3A.5.-….
560 120 680 1245 835 180 985 180 315 28
1LP13.-3A.7.-…. ● 560 120 680 1245 835 180 985 200 315 28
28 35 1590 1905 85
M20 170 140 22 90
28 35 1610 1925 95
M24 170 140 25 100
1LP12.-3A.5.-….
630 150 780 1305 800 220 980 200 355 35
1LP12.-3A.7.-…. ● 630 150 780 1305 800 220 980 224 355 35
35 42 1725 1975 95
M24 170 140 25 100
1LP13.-3A.5.-….
630 150 780 1305 800 220 980 200 355 35
1LP13.-3A.7.-…. ● 630 150 780 1305 800 220 980 224 355 25
35 42 1725 2075 95
355
4, 6
4, 6
Dimension designation acc. to IEC
A
AA
AB
AC
● Bearing design for increased cantilever forces, for type of
construction IM B3 only.
9/22
Siemens D 81.8 · 04/2014
B
BA
BB
1)
C
H
HA K
K'
L 1)
LM1)
D
DB
E
EB
F
GA
35 42 1790 2040 100 M24 210 180 28 106
M24 170 140 25 100
35 42 1790 2140 100 M24 210 180 28 106
With type of construction IM V1, dimensions L or LM
may increase due to a protective cover for the fan motor.
© Siemens AG 2014
Forced-air cooled motors — open version
Dimensions
1LP1 motors
Axially mounted equipment unit
■ Dimensional drawings
IM B3 type of construction
For terminal box dimensions, see Page 9/25
L
LL
BE
HB'
HK
HC
GA
HD
AC
ØD
F
HB
AG
AD
BC
H
HA
EB
DB
BA
E
G_D081_XX_00418
C
ØK
B
BB
Ø K'
AA
A
AB
IM B35 and IM V1 types of construction
For flange dimensions, see Page 9/24 (Z = the number of retaining holes),
for terminal box dimensions, see Page 9/25
L
LL
HC
HB'
HK
HH
BE
AD
AG
HB
ZxS
AQ
AC
ØP
ØN
ØD
F
E
GA
DB
G_D081_XX_00419
BA
C
Frame No. of
size
poles
Motor type
315
1LP12..-3A.1.-....
1LP12..-3A.3.-....
4, 6
4, 6
1LP12..-3A.5.-….
1LP12..-3A.7.-….
ØK
Ø K'
B
BB
AA
A
AB
Dimension designation acc. to IEC
A
1LP12..-3A.5.-....
1LP12..-3A.7.-....
355
M
H
HA
EB
LA
LE
9
LM
HD
T
AA
AB
AC AQ B
BA
BB
C
H
HA K
K' L
LM
D
560 120 680 630 670 630 180 780 180 315 28 28 35 1525 1685 85
● 560 120 680 630 670 630 180 780 200 315 28 28 35 1545 1705 95
560 120 680 630 670 835 180 985 180 315 28 28 35 1665 1825 85
DB
E
EB
F
GA
M20 170 140 22 90
M24 170 140 25 100
M20 170 140 22 90
● 560 120 680 630 670 835 180 985 200 315 28 28 35 1685 1845 95
M24 170 140 25 100
630 150 780 710 750 800 220 980 200 355 35 35 42 2115 2300 95
M24 170 140 25 100
● 630 150 780 710 750 800 220 980 224 355 35 35 42 2180 2365 100 M24 210 180 28 106
● Bearing design for increased cantilever forces, for type of construction IM B3 only.
Siemens D 81.8 · 04/2014
9/23
© Siemens AG 2014
Forced-air cooled motors — open version
Dimensions
Flanges
G_D081_XX_00026
■ Dimensional drawings
(Z = the number of retaining holes)
Flange with through holes
Motor type
Frame size
No. of poles
Type of construction
Flange type
Dimension designation acc. to IEC
LA
1LP1
315
355
4, 6
4, 6
9
9/24
Siemens D 81.8 · 04/2014
IM B35, IM V1
IM B35, IM V1
LE
M
N
P
S
T
Z
8
Flange
29
170
740
680
800
22
6
Flange (optional)
22
170
600
550
660
22
6
8
Flange
29
170
840
780
900
22
6
8
Flange (optional)
22
170
600
550
660
22
6
8
© Siemens AG 2014
Forced-air cooled motors — open version
Dimensions
Terminal boxes
■ Dimensional drawings
LL
BE
HB'
HK
HC
AG1
IM B3 type of construction
HD
HB
AG
AD
BC
G_D081_XX_00426
LL
HC
HB'
HK
HH
AG1
IM B35 and IM V1 types of construction
HD
HB
AG
AD
BE
9
G_D081_XX_00427
Motor
type
Frame
size
No. of
poles
Terminal box
Dimension designation acc. to IEC
AD
AG
AG1
BC
BE
HB
HB'
HH
HC
HD
HK
LL
1LP1
315
4, 6
1XB7 730
710
575
–
115
–
890
310
295
180
1025
255
345
1XB7 731
710
575
–
115
115
890
310
295
180
1025
255
345
1XB7 740
800
615
60
115
150
930
365
295
235
1110
340
425
GT640
655
555
–
115
110
870
225
295
155
970
170
310
1XB1 621
705
585
–
115
150
900
305
295
165
1020
250
330
1XB1 631
775
640
–
115
100
955
400
295
175
1090
320
555
1XB7 730
750
615
–
100
–
970
310
300
180
1105
255
345
1XB7 731
750
615
–
100
115
970
310
300
180
1105
255
345
1XB7 740
840
655
60
100
150
1010
365
300
235
1190
340
425
GT640
695
595
–
100
110
950
225
300
155
1050
170
310
1XB1 621
745
625
–
100
150
980
305
300
165
1100
250
330
1XB1 631
815
680
–
100
100
1035
400
300
175
1170
320
555
355
4, 6
Siemens D 81.8 · 04/2014
9/25
© Siemens AG 2014
Forced-air cooled motors — open version
Dimensions
Notes
9
9/26
Siemens D 81.8 · 04/2014
10
© Siemens AG 2014
Explosion-proof motors
10/2
10/2
10/2
10/2
10/3
10/3
10/4
10/4
10/4
10/4
10/4
10/4
10/5
10/7
10/7
10/7
Technical information
Overview
Classification of zones
Types of protection
Certification
Overview of SIMOTICS FD
1MM, 1MH, 1MQ, 1MN
explosion-proof motors
Benefits
Application
Technical specifications
General information
Type of protection Ex nA
for use in Zone 2
Type of protection Ex tc
for use in Zone 22
Converter-fed (1MM1, 1MH1, 1MQ1,
1MN1) or mains-fed operation (1LH1)
VIK version
Coolant temperature
Special technology
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Explosion-proof motors
Technical information
■ Overview
In many industrial and public sectors, explosion protection or
explosion hazards are ever-present, e.g. in the chemicals industry, in refineries, on drilling platforms, at petrol stations, in feed
manufacturing and in sewage treatment plants.
The risk of explosion is always present when gases, fumes, mist
or dust are mixed with oxygen in the air in an explosive ratio
close to sources of ignition that are able to release the so-called
minimum ignition energy.
In the chemical and petrochemical industries in particular, when
crude oil and natural gas are transported, or in mining, milling
(e.g. grain and granular solids), this can result in serious injury
to persons and damage to equipment.
Classification of zones
Areas subject to explosion hazard are divided into zones. Division into zones depends on the chronological and geographical
probability of the presence of a hazardous, potentially explosive
atmosphere. Information and specifications for classification of
the zones are laid down in the following standards:
• IEC/EN 60079-10-1 for gas atmospheres
• IEC/EN 60079-10-2 for dust atmospheres
Further, a distinction is made between various explosion groups
as well as temperature classes and these are included in the
hazard assessment.
To ensure maximum safety in these areas, legislators in most
countries have implemented appropriate stipulations in the form
of laws and regulations based on national and international
standards.
Zone classification
Gas atmosphere
Zone classification
Dust atmosphere
Zone 22
Explosion-protected equipment is designed such that an explosion can be prevented when it is used properly.
Zone 21
Safe Area
The explosion-protected equipment can be designed in accordance with various types of protection.
Zone 20
The local conditions must be subdivided into specified zones by
the user with the assistance of the responsible authorities in
accordance with the frequency of occurrence of an explosion
hazard. Device (equipment) categories are assigned to these
zones. The zones are then subdivided into possible types of protection and therefore into possible equipment (product) types.
Zone 0
Zone 1
Safe Area
Zone 2
G_D081_EN_00339
Depending on the particular zone and therefore the associated
hazard, operating equipment must comply with defined minimum
requirements regarding the type of protection. The different types
of protection require corresponding measures to prevent ignition
that should be implemented at the motor in order to prevent that a
surrounding explosive atmosphere is ignited.
10
Zone
Zone definition acc. to
Gas1)
Dust1)
IEC/EN 60079-10-1 for gas atmospheres
IEC/EN 60079-10-2 for dust atmospheres
Assigned types
of protection
Category acc.
to 94/9/EC
2
–
An area in which in normal operation it is expected that an explosive gas atmosphere
will occur only rarely and then only briefly.
Ex nA
3G
–
22
An area in which in normal operation it is expected that an explosive gas atmosphere
in the form of a cloud of dust in air will occur only rarely and then only briefly.
Ex tc2)
3D
Types of protection
Type of protection "Non-sparking" Ex nA acc. to IEC/EN 60079-15
Explosion-proof motors for converter-fed operation
The type of protection Ex nA ensures that a motor in normal operation as well as when operated under deviating conditions as
specified in the standard is not in a position to ignite a surrounding explosive gas atmosphere.
This type of protection applies for electrical equipment protected using an enclosure and with limited surface temperature
for use in areas in which combustible dust can occur in concentration levels that could cause a fire or an explosion.
Principally, explosion-proof motors can be fed from converters.
Particular attention must be paid to the interaction between the
motor and converter system, especially with regard to the
following aspects:
• The harmonic content of the supply voltage raises the motor
temperature, so the motor output must be reduced (see
derating)
• Less cooling of the motor at speeds below the rated speed
• Voltage stress on the motor winding
• Bearing currents
1)
2)
Type of protection "Dust explosion protection" Ex tc acc. to
IEC/EN 60079-31
Motors, which are certified for gas or dust protection, must not be used
in hybrid mixtures! Hybrid mixtures: When explosive gas and dust
atmospheres occur simultaneously.
10/2
Siemens D 81.8 · 04/2014
Motors are not approved for operation in environments containing
conductive dust
© Siemens AG 2014
Explosion-proof motors
Technical information
■ Overview (continued)
Certification
IEC motors for use in hazardous zones are certified according
to the IEC/EN 60079-0, IEC/EN 60079-15 or IEC/EN 60079-31
standards and EC Directive 94/9/EC (ATEX) and are marked
according to the following schematic.
Example "explosion-proof enclosure":
CE
0158
II
2
G
Ex
de
IIC
T4
X
CE marking
Number of the certifying "notified" body (e.g. 0158 = EXAM)
(not Zones 2, 22)
Explosion protection marking (symbol)
Device group:
I = Underground
II = All other areas
Category Part 1 (zone):
1 (Zone 0/20),
2 (Zone 1/21),
3 (Zone 2/22)
Category Part 2 (Ex atmosphere)
G = Gas
D = Dust
Explosion protected equipment
Type of protection (e.g. nA or tc)
Explosion group and explosion subgroup
II = Gas (IIA, IIB or IIC)
III = Dust (IIIA, IIIB or IIIC)
Temperature class or max. surface temperature
T1 = 450 °C
T2 = 300 °C
T3 = 200 °C
T1 = 25 °C
Special conditions according to the operating instructions or EC type examination certificate
Additional information on the subject of explosion protection,
types of protection and zones is provided in the Siemens
brochure "Explosion Protection".
Overview of SIMOTICS FD 1MM, 1MH, 1MQ, 1MN explosion-proof motors
SIMOTICS FD explosion-proof motors (1MM, 1MH, 1MQ, 1MN)
correspond to the SIMOTICS FD non-explosion-proof motors
(1LM, 1LH, 1LQ, 1LN). All technical specifications can be found
in the selection and ordering data for the non-Ex motors 1LM,
1LH, 1LQ, 1LN (sections 4 to 7 of the catalog), whereby the rated
output is subjected to derating in accordance with defined
factors. For derating factors, see "Technical specifications"
section "Derating".
Sector
Cate- Zone Frequency
gory
of occurrence
of the Ex
atmosphere
Type of
protection
Gases and
vapors (G)
3G
Ex nA IIC
T1 – T3
(non-sparking)
Dust (D)
3D
2
22
rarely or
briefly
rarely or
briefly
Ex tc IIIB
(non-conductive dust)
To order explosion-proof motors, the letter "L" in position 2 of the
Article No. for non-Ex motors must be replaced with the letter
"M".
The table below contains a complete overview of our explosionproof motors, their types of protection and their assignment to
categories. It is important to note that depending on whether the
motor is used for converter-fed operation or mains-fed operation, different order codes are required for unique selection of
the required motor.
TemperaDegree Motor type
Operation Order
ture class,
of pro- (pos. 1-4
code
max.
tection of Article No.)
surface
temperature
T125 °C
IP55
IP55
1MM1
1MH1
1MQ1
1MN1
Mains
(1MH1)
1MM1
1MH1
1MQ1
1MN1
Mains
(1MH1)
M72
Utilization
according
to thermal
class
Standard
130 (B)
155 (B)
IEC/EN 60079-0
IEC/EN 60079-15
Converter M73
M35
130 (B)
155 (F)
IEC/EN 60079-0
IEC/EN 60079-31
Converter M39
Siemens D 81.8 · 04/2014
10/3
10
© Siemens AG 2014
Explosion-proof motors
Technical information
■ Benefits
The explosion-proof motors from Siemens offer the user
numerous advantages:
• The motors are designed to IEC/EN 60079-0 and
IEC/EN 60079-15 or IEC/EN 60079-31 and EC Directive
94/9/EC (ATEX). As product supplier, Siemens accepts
responsibility for compliance with the applicable product
standards for the selected equipment.
• By using this product, the plant operating company satisfies
Directive 1999/92/EC in accordance with Appendix II B. The
plant operating company is responsible for correct selection
and proper use of the equipment.
• Comprehensive series of Ex motors for protection against gas
and dust.
• Individual versions of motors are possible thanks to the
numerous catalog order codes.
• Further special versions are possible on request.
• The Operating Instructions (Compact) are available in all the
official EU languages as well as Russian and Chinese.
■ Application
The explosion-proof motors are used in the following sectors to
prevent explosion hazards that result in serious injury to
persons and severe damage to equipment.
• Chemical and petrochemical industry
• Production of mineral oil and gas
• Gas works
• Gas supply companies
•
•
•
•
•
•
Petrol stations
Coking plants
Mills (e.g. grain, solids)
Sewage treatment plants
Wood processing (e.g. sawdust, tree resin)
Other industries subject to explosion hazards
■ Technical specifications
General information
Ex motors in vertical type of construction with shaft extension
pointing down must have a protective cover (position 14 of
Article No.: G).
Extensive Operating Instructions (Compact) are supplied as
standard with explosion-proof motors in English and German.
Translations are also available in all the other official EU
languages as well as in Russian and Chinese.
For all explosion-proof motors, designs according to UL (order
code D31) and CSA (order code D40) are not possible.
10
Motor connection
For 1MM1, 1MH1, 1MQ1 and 1MN1 motors in the explosionproof design, the cable entry plate is supplied undrilled as standard. This enables you to adapt the number and size of the boreholes to the rated conditions. The cable entry can be rotated by
180°.
The certificates for the motors for hazardous areas are stored
with the documentation in the selection tool DT Configurator.
Certified motor protection switches/tripping units must always
be used for motor protection, see Catalog IC 10.
When metal armored cables are routed into the auxiliary terminal
boxes, the metal shield must only be grounded once: either in
the auxiliary terminal box or in the control room of the operator.
In the case of SIMOTICS FD motors 1MM1, 1MH1, 1MQ1 and
1MN1, monitoring of the bearing temperature is only mandatory
for Zone 22 (order code A72).
Type of protection Ex nA for use in Zone 2
• Design for Zone 2 for mains-fed operation
(order code M72)
• Design for Zone 2 for converter-fed operation
(order code M73)
1MM1, 1MH1, 1MQ1 and 1MN1 motors are modified for this
purpose in the "Non-sparking" design and are suitable for use
in hazardous areas of Zone 2 for temperature classes T1 to T3.
The maximum surface temperature that can occur during operation is below the limit temperature of the respective temperature
10/4
Siemens D 81.8 · 04/2014
class. The ventilation system complies with IEC/EN 60079-0/
-15/-31. The motors are equipped with an external grounding
terminal. The terminal box is designed for Ex e type of
protection.
Ambient temperature -0 °C to +60 °C, whereby derating applies
from 40 °C upwards. Other temperatures are available on
request.
The rating plate or the extra rating plate contains the text:
II 3G
Ex nA IIC T3
Type of protection Ex tc for use in Zone 22
Ex tc in accordance with IEC/EN 60079-31 for Zone 22 with
non-conductive dust (IP55)
• Design for Zone 22 for mains-fed operation
(order code M35)
• Design for Zone 22 for converter-fed operation
(order code M39)
1MM1, 1MH1, 1MQ1 and 1MN1 motors are modified for this
purpose for use in zones subject to dust and explosion hazards.
The surface temperature is ≤ 125 °C at rated duty.
An external grounding terminal and a metal external fan are
fitted to the motors.
Certification:
• Zone 22: EC Declaration of Conformity,
IEC Ex Certificate of Conformity
Identification on the rating plate (extra rating plate for
SIMOTICS FD motors):
• Zone 22:
II 3D Ex tc IIIB T125 °C
Ambient temperature -0 °C to +60 °C, whereby derating applies
from 40 °C upwards. Other temperatures are available on
request.
This version can be ordered with the note "Operation in Zone 2
or Zone 22".
© Siemens AG 2014
Explosion-proof motors
Technical information
■ Technical specifications (continued)
Converter-fed (1MM1, 1MH1, 1MQ1, 1MN1) or
mains-fed operation (1LH1)
With converter-fed operation, the torque reduction factors for
drives for fans, pumps and compressors must be configured
according to the table in the section "Derating". The torque
reduction factors for constant torque drives will be configured,
on request, on specification of the speed control range and the
required torque.
For converter-fed operation, Ex motors must always be monitored using PTC thermistors. Certified tripping units are required
for this purpose, see Catalog IC 10.
Explosion-proof motors 1MM1, 1MH1, 1MQ1 and 1MN1
The motors of the 1MM1, 1MH1, 1MQ1 and 1MN1 series are
available in Ex nA (Zone 2) or Ex tc (Zone 22) types of protection.
The motors have PTC thermistors for alarm and tripping in accordance with thermal class 155 (F).
Ambient temperatures in the range from -20 to +60 °C are possible, whereby additional derating applies from +40 °C upwards.
Please inquire in such cases.
For 1MM1 motors, order code K35 (metal external fan) must be
specified in the order. The 1MM1...-3BB..-1… motors are an
exceptional case, however, because they are equipped with a
unidirectional external fan. When ordering these motors, order
code K37 must be specified for clockwise rotation or order code
K38 for anticlockwise rotation.
An EC Declaration of Conformity is enclosed with every motor.
In the case of motors for converter-fed operation, the following
information must be supplied in the order or inquiry in plain text:
• For a constant torque drive (order code B61: T = const) or
drives for fans, pumps and compressors (order code B60:
M ~ n2) *)
• Maximum load torque
• Speed control range
• Utilized thermal class that the motor should
or must comply with
Note:
Motors of the 1L.1 series (non-Ex motors) are utilized in accordance with thermal class 180 (H)/155 (F) (or 155 (H)/130 (B) –
order code C10). Derating of motors of the 1M.1 series (Ex motors) results in a corresponding reduction in thermal utilization.
These specifications regarding operation are labelled on an
extra rating plate on the motor. The rating data on the rating plate
is specified for the load torque at maximum speed.
Type of protection Ex nA for use in Zone 2
The motors are modified for operation in Zone 2 and designed
for compliance with temperature class T3 (maximum surface
temperature of 200 °C inside the motor).
• Design for Zone 2 for mains-fed operation –
order code M72:
Standard utilization in accordance with thermal class 130 (B).
Utilization in accordance with thermal class 155 (F) with
service factor (order code C14) possible on request.
• Design for Zone 2 for converter-fed operation –
order code M73:
Standard utilization in accordance with thermal class 155 (F)
in drives for fans, pumps and compressors (order code B60:
M ~ n2) *). For utilization in accordance with thermal class 130
(B) the output must be reduced by 14 % from the rated output
of a comparable 1L.1 (non-Ex) motor. In constant torque
*)
drives (order code B61: T = const) the thermal utilization
depends on the value of the load torque and the speed control
range ( 130 (B) and/or 155 (F)). The maximum possible
constant torque is dependent on the speed control range and
the cooling method of the motor  thermal torque limit
characteristic.
IEC/EN 60079-15 specifies that the motor and converter must
be tested as a unit. As an alternative, however, it is also admissible for the thermal response to be determined by a calculation. The thermal response of the motors for operation on
Siemens converters is known, so a system test is not generally
required for drives for fans, pumps and compressors. Please
inquire as to whether a system test is necessary or not in the
case of a constant torque drive  constant torque drives on
request only.
The following identification is included on an extra rating plate on
the motor:
II 3G Ex nA IIC T3 Gc, IEC/EN 60079
Type of protection Ex tc for use in Zone 22 for non-conductive
dust
The motors are modified for operation in Zone 22 and designed
such that an external motor surface temperature of 125 °C is not
exceeded. For the 1MM1, 1MH1, 1MQ1 and 1MN1 motor series,
monitoring of the bearing temperature is required for operation
in Zone 22. These motors are therefore equipped with bearing
temperature sensors as standard.
• Design for Zone 22 for mains-fed operation –
order code M35:
Standard utilization in accordance with thermal class 130 (B).
Utilization in accordance with thermal class 155 (F) with
service factor (order code C14) possible on request.
• Design for Zone 22 for converter-fed operation –
order code M39:
Standard utilization approximately in accordance with thermal
class 155 (F) in drives for fans, pumps and compressors
(order code B60: M ~ n2) *). For utilization in accordance with
thermal class 130 (B) the output must be reduced by 14 %
from the rated output of a comparable 1L.1 (non-Ex) motor.
In constant torque drives (order code B61: T = const) the
thermal utilization depends on the value of the load torque and
the speed control range ( 130 (B) and/or 155 (F)). The
maximum possible constant torque is dependent on the
speed control range and the cooling method of the motor
 thermal torque limit characteristic. When configuring these
motors, therefore, it is important to note that the maximum
admissible torque, as a function of speed, is not exceeded.
Please inquire as to whether a system test is necessary or not
in the case of a constant torque drive  constant torque
drives on request only.
The following identification is included on an extra rating plate on
the motor:
II 3D Ex tc IIIB T125 °C Dc, IEC/EN 60079
Operation on non-Siemens converter
It is normally necessary to inquire regarding operation of the
motors on a non-Siemens converter, regardless of the type of
protection and torque characteristic of the driven machine.
A test must be performed to ensure that the temperature limits
are complied with. This should take place at the customer's
premises (not possible in the factory).
M = Torque
Siemens D 81.8 · 04/2014
10/5
10
© Siemens AG 2014
Explosion-proof motors
Technical information
■ Technical specifications (continued)
Derating
In comparison to non-Ex motors, the rated output of Ex motors
is reduced. Derating is performed in accordance with defined
factors. The reference output here is the rated output of the
non-Ex motor.
Derating factors for motors of the 1M.1 series
Motor type
Zone (order code)
Zone 2 (M72)
Zone 2 (M73)
Zone 22 (M35)
Zone 22 (M39)
Torque (order code) *)
M ~ n2 (B60)
M ~ n2 (B60)
T = const (B61)
M ~ n2 (B60)
M ~ n2 (B60)
T = const (B61)
1MM1
–
0.9
O. R.
–
0.8
O. R.
1MQ1
–
0.9
O. R.
–
0.8
O. R.
1MH1
1
0.9
O. R.
1
0.9
O. R.
1MN1
–
0.9
O. R.
–
1
O. R.
Rating plate labeling for Ex motors of the SIMOTICS FD series
Rating plate
In contrast to the non-Ex motor, the rating plate specifies that the
voltage tolerance is compliant with IEC/EN 60034-1, Zone A.
3~ Mot. 1MM1222-3AB71-2AA0-Z
m: 1.8 t
IP 55
nmax: 3000 1/min
U [V]
I [A]
380 D
*)
580
SIMOTICS FD
IM B3 Ta: -20…+40°C
If, in addition to order code M72 or M73, order code D36
(conformity statement) and/or D37 (IEC Ex certificate) is also
specified in the order, the corresponding certificate numbers will
be stamped on the rating plate (only applicable to order codes
M72 and M73).
NoN- 9900006060001 / 2014
Th.Cl.: 180(H) Util.:155(F)
IEC/EN 60034-1
P [kW] cosφ n [1/min] f [Hz]
320
0.87
1500
50.30
*)
Valid for:
Order code M72: Zone 2 for mains-fed motors
Order code M73: Zone 2 for converter-fed motors
Order code M35: Zone 22 for mains-fed motors
Order code M39: Zone 22 for converter-fed motors
Eff.
96.2%
Mot. design: FOR INVERTER DUTY ONLY
Line supply: 400V/50Hz
10
DEW0400
Made in Germany D-90441 Nürnberg
G_D081_XX_00471
*) VARIATIONS ACC. TO IEC/EN 60034-1, ZONE A
Extra rating plate
On the extra rating plate, the torque characteristic, speed or
frequency control range and the torque are specified as a
minimum.
If, in addition to order code M72 or M73, order code D36
(conformity statement) and/or D37 (IEC Ex certificate) is also
specified in the order, the corresponding certificate numbers will
be stamped on the rating plate (only applicable to order codes
M72 and M73).
torque characteristic: M~n2
Z0400
speed range: 150...1500 rpm
max. torque: 2037 Nm
G_D081_XX_00472
*)
M = Torque
10/6
Siemens D 81.8 · 04/2014
Valid for:
Order code M73: Zone 2 for converter-fed motors
Order code M39: Zone 22 for converter-fed motors
Order code B60: M ~ n2 *)
© Siemens AG 2014
Explosion-proof motors
Technical information
■ Technical specifications (continued)
Ex plate
Special technology
Zone 2:
"Special technology" comprises mounted technology that is
compatible with explosion-proof motors.
Explosion-proof motors can be implemented in a broader range
of applications when explosion-proof rotary pulse encoders or
explosion-proof separately driven fans are mounted.
I I 3G
Z9955
Ex nAe ll T3 Gc
IEC / EN 60079
D21377367010001
G_D081_XX_00470
Note:
The letter(s) between "Ex nA" and "II T3 Gc" vary according to the
additional components of the motor (e.g. temperature sensor,
anti-condensation heating, etc.).
Valid for:
Order code M72: Zone 2 for mains-fed motors
Order code M73: Zone 2 for converter-fed motors
Zone 22:
Z9955
DD1406366010001
For motors of the 1MQ1 series with forced ventilation, only radially mounted separately driven fans are available (position 16 of
Article No. = 2, 3, 4).
Explosion-proof rotary pulse encoder
The rotary pulse encoder can only be mounted on a standard
non-drive end (NDE), i.e. a second shaft extension or protective
cover cannot be supplied. In the case of a vertical mounting
position for motors of the 1MM1 series, therefore, a suitable
cover must be implemented by the customer to prevent small
parts from falling into the fan cover (see also standard
IEC/EN 60079-0).
The type of protection of the rotary pulse encoder must be
observed. The relevant data are stamped on the rating plate of
the rotary pulse encoder.
I I 3D
Ex tc IIIB T125°C Dc
IEC / EN 60079
The use of a separately driven fan is recommended to increase
motor utilization at low speeds and to limit noise generation at
speeds significantly higher than the synchronous speed.
G_D081_XX_00469
Valid for:
Order code M35: Zone 22 for mains-fed motors
Order code M39: Zone 22 for converter-fed motors
VIK version
• VIK standard version – Order code K30
"VIK" identification on rating plate.
• VIK Ex n version – Order codes K30 + C27
"VIK" and "Ex nA IIC T3" identification on the rating plate
according to Directive 94/9/EC (ATEX)
"Ex nA IIC T3" identification will only be included on the rating
plate on request as recommended by VIK.
Note: Order code C27 can only be ordered in combination
with order code K30.
Both versions include technology for Zone 2 to type of protection
Ex nA IIC T3.
Motors up to frame size 355 can be supplied in accordance with
the technical requirements of the VIK ("Verband der Industriellen
Energie- und Kraftwirtschaft e. V.", the Association of the
Industrial Energy and Power Industry).
Coolant temperature
Coolant temperature –40 to +40 °C for explosion-proof motor
For all 1MM1, 1MH1, 1MQ1 and 1MN1 motors in explosion
protection types Ex nA or Ex tc (Zone 2/22), the operating
ambient temperature range can be optionally increased to
– 40 °C. Extensive technical measures are necessary in this
case (e.g.: metal external fan).
Order code D19
When an explosion-proof rotary pulse encoder is mounted, the
length of the motor increases by dimension l. For an explanation
of the additional dimensions and weights, see "Dimensions and
weights of explosion-proof rotary pulse encoders" on the website
of the encoder manufacturer.
HOG 10 and HOG 11 rotary pulse encoders
The HOG 10 and HOG 11 rotary pulse encoders have an extremely rugged design and are therefore ideally suited to difficult
operating conditions.
The following order codes are available for explosion-proof
rotary pulse encoders (ATEX):
• H73: HOG 10 D 1024 I
• H83: HOG 10 DN 2048
• H88: HOG 11 DN 1024 I (16 mm) special corrosion protection
Encoder mounting for use below –20 °C and above +40 °C is
available on request.
Please consult the manufacturer's website for further information
and technical specifications of the encoders.
Manufacturers of rotary pulse encoders
Types: HOG 10, HOG11:
Baumer Hübner GmbH
Max-Dohrn-Str. 2+4
10589 Berlin
Germany
Tel. +49 (0)30-6 90 03-0
Fax +49 (0)30-6 90 03-1 04
www.baumerhuebner.com
E-mail: [email protected]
Siemens D 81.8 · 04/2014
10/7
10
© Siemens AG 2014
Explosion-proof motors
Technical information
Notes
10
10/8
Siemens D 81.8 · 04/2014
11
© Siemens AG 2014
Article No. supplements
and special versions
11/2
11/3
11/4
11/5
11/6
11/7
11/7
11/20
Voltages
Types of construction
Terminal box position
Separately driven fan position/
Heat exchanger position
Mechanical limit speed
Options
• Motors without explosion protection
• Explosion-proof motors
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Article No. supplements and special versions
Voltages
■ Selection and ordering data
Special
versions
Voltage code
12th position of
the Article No.
System
Catalog section
description
4
5
6th position of
the Article No.
Air-cooled, enclosed
version
with selfventilation
1LM1
6
7
8
Water-cooled version
with forced-air
cooling
1LQ1
with waterjacket cooling
1LH1
9
Air-cooled, open version
with heat
exchanger
1LN1
with selfventilation
1LL1
with forced-air
cooling
1LP1
400 V
1 Mains-fed
operation
Converter-fed
operation with
IICC C 500
insulation
system
500 V
2 Converter-fed
operation with
IICC C 500
insulation
system
Converter-fed
operation with
IICC C 690
insulation
system
0
–
1, 2, 4, 6
3
 
 
 
 
 
 
1, 3
4, 6
 
 
 
 
 
 
2
4, 6
 
 
 
 
 
 
 
 
 
 
 
 
–
–
 
–
–
–
690 V
without
output filter
3 Converter-fed
operation with
IICC C 690
insulation
system
1, 2, 4, 6
3
690 V
with
output filter
4 Mains-fed
operation
0
Converter-fed
operation with
IICC C 500
insulation
system
4, 6, 8
1, 2, 4, 6
3
–
–
–
–
–
 
 
 
 
 
 
–
–
 
–
–
–
Voltage at 60 Hz and 60 Hz output required
11
460 V; 60 Hz
output
575 V; 60 Hz
output
5 Mains-fed
operation
0
11/2
–
–
–
–
–
Converter-fed
operation with
IICC C 500
insulation
system
1, 2, 4, 6
3
 
 
 
 
 
 
6 Converter-fed
operation with
IICC C 690
insulation
system
1, 2, 4, 6
3
 
 
 
 
 
 
Without additional charge
Not possible

–
4, 6, 8
Siemens D 81.8 · 04/2014
455
355
–
Voltage at 50 Hz and 50 Hz output
400
315
–
455
–
400
355
–
315
–
455
355
 
400
315
455
400
355
315
–
455
–
400
355
–
315
–
455
355
4, 6, 8
400
No. of
poles
315
1L.1 . . . - . . . . ■ - . . . . 1L.1 . . . ■ - . . . . . - . . . . Frame size
© Siemens AG 2014
Article No. supplements and special versions
Types of construction
■ Selection and ordering data
Types of construction
Type of
Catalog section
construction
4
5
code 14th
position of
Air-cooled, enclosed
the
version
Article No.
with selfwith forced-air
ventilation
cooling
1LM1
6
7
8
Water-cooled version
9
Air-cooled, open version
with waterjacket cooling
with heat
exchanger
with selfventilation
with forced-air
cooling
1LH1
1LN1
1LL1
1LP1
1LQ1




IM V5
C
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
IM V6
D
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
IM V15
E
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
IM B5
with
support
foot
F
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
–
–
O. O.
R. R.
O. O.
R. R.
IM V1
with
protective
cover
G
✓
✓
✓
✓
–
–
–
–
✓
✓
✓
✓
IM V1
without
protective
cover
J
✓
✓
✓
✓
✓
✓
✓
✓
–
–
–
–
IM B35
K
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
✓
455
355
A
400
315

455
355

400
315

455
355

400
315

455
355

400
315

455
355

400
315
455
355
IM B3
1L.1. . . - . . . . . - . ■ . .
400
315
Frame size
Without flange
With flange
11

Standard version
✓
With additional charge
–
Not possible
O. R. On request
Siemens D 81.8 · 04/2014
11/3
© Siemens AG 2014
Article No. supplements and special versions
Terminal box position
■ Selection and ordering data
Terminal box position
Terminal
Catalog section
box position
4
5
code 15th
position
Air-cooled, enclosed
of the
version
Article No.
with selfwith forced-air
ventilation
cooling
1LM1
6
7
8
Water-cooled version
9
Air-cooled, open version
with waterjacket cooling
with heat
exchanger
with selfventilation
with forced-air
cooling
1LH1
1LN1
1LL1
1LP1
1LQ1
Standard version
(terminal box on DE top)
A





–
–




Version with one terminal box
Terminal box on DE
right-hand
B


✓
✓




–
–
–
–
Terminal box on DE
left-hand
C


✓
✓




–
–
–
–
Terminal box on NDE top
D
✓
✓
✓
✓
✓
✓
–
–
✓
✓
✓
✓
1)
1)
1)
1)
✓
✓
1)
1)
✓
✓
1)
1)
Terminal box on NDE
right-hand
E
Terminal box on NDE
left-hand
F
✓
✓
✓
✓
✓
✓
✓
✓
–
–
–
–
✓
✓
✓
✓
–
–
–
–
Version with two terminal boxes
11
Terminal boxes both top
(NDE and DE)
K
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Terminal boxes both
left-hand
(NDE and DE)
L
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Terminal boxes both
right-hand (NDE and DE)
M
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Terminal boxes both
on DE (right-hand and
left-hand)
N
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Terminal boxes both
on NDE (right-hand and
left-hand)
O
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Standard version
Without additional charge
✓
With additional charge
–
Not possible
O. R. On request


1)
Possible terminal box positions dependent on separately driven fan
position.
11/4
Siemens D 81.8 · 04/2014
455
355

Terminal box position
400
315
455
355
400
315
455
355
400
315
455
355
400
315
455
355
400
315
455
400
355
1L.1. . . - . . . . . - . . ■ .
315
Frame size
© Siemens AG 2014
Article No. supplements and special versions
Separately driven fan position/Heat exchanger position
■ Selection and ordering data
Separately driven fan
position/Heat exchanger
position
Separately
Catalog section
driven fan/heat
4
5
exchanger
position code
Air-cooled, enclosed
16th position
version
of the
with selfwith forced-air
Article No.
ventilation
cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forced-air
cooling
1LM1
1LH1
1LN1
1LL1
1LP1
6
7
8
Water-cooled version
1LQ1
9
Air-cooled, open version
–
–


–
–


–
–
455
355

400
315
455
355
400
315
455
355
400
315
455
355
400
315
455
355
400
315
455
400
355
1L.1. . . - . . . . . - . . . ■
315
Frame size
Separately driven fan position/Heat exchanger position
No separately driven fan,
no heat exchanger
0

Separately driven fan for air-cooled motors
Separately driven fan unit 1
NDE, axial
–
–
–
–
–
–
–
–
–
–
–
–
Separately driven fan unit 2
NDE, top
–
–


–
–
–
–
–
–


Separately driven fan unit 3
NDE, right-hand
–
–


–
–
–
–
–
–


Separately driven fan unit 4
NDE, left-hand
–
–


–
–
–
–
–
–


–
–
–
–
–
–
✓
✓
–
–
–
–
Heat exchanger for modular motors
Heat exchanger, top


✓
–
5
Standard version
Without additional charge
With additional charge
Not possible
11
Siemens D 81.8 · 04/2014
11/5
© Siemens AG 2014
Article No. supplements and special versions
Mechanical limit speed
■ Selection and ordering data
Mechanical limit speed for non-standard type of construction or bearings
Motor type
Type of
construction
1..1...-3AB..-....
1..1...-3AC..-....
1..1...-3BB..-....
1..1...-3BC..-....
with order code
–
K20
M61
–
K20
M61
–
K20
M61
–
K20
M61
IM B3
3000
2600
–
2600
2600
–
2600
2400
–
2200
2200
–
IM B35
3000
–
3000
2600
–
2600
2600
–
2400
2200
–
2400
IM V1
2500
–
1500
2500
–
1500
2000
–
1000
2000
–
1000
IM V15, V5, V6
O. R.
O. R.
The mechanical limit speed for IM B3 type of construction is
entered in the selection and ordering data in accordance with
the cooling method. For types of construction other than IM B3,
or order codes such as K20 or M61, the mechanical limit speed
reduces in accordance with the table.
11
11/6
Siemens D 81.8 · 04/2014
O. R.
O. R.
© Siemens AG 2014
Article No. supplements and special versions
Options
Motors without explosion protection
■ Selection and ordering data
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled,
enclosed version
7
8
Water-cooled
version
9
Air-cooled,
open version
with selfventilation
with forcedair cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forcedair cooling
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
–
–
–
6 PTC thermistors for alarm and
A12
tripping, without lightning arresters 6)
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
2 temperature sensors KTY 84-130
A25
 
 
 
 
 
 
6 temperature sensors KTY 84-130
A27
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
6 Pt100 resistance thermometers 6)
A61
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
6 Pt100 resistance thermometers,
3-wire circuit from auxiliary terminal
box (option M50 or M88) 6)
A64
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
A72
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
2 Pt100 screw-in resistance therA78
mometers in basic circuit for rollingcontact bearings, 3-wire circuit from
auxiliary terminal box
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
2 Pt100 double screw-in resistance
thermometers in 3-wire circuit for
rolling-contact bearings
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
–
–
–
455
355
–
400
315
–
455
355
–
400
315
–
455
355
–
400
315
–
455
355
–
400
315
455
355
400
315
455
400
355
✓ ✓
1L .1. . . - . . . . . - . . . . -Z
315
Frame size
Preferred motors
Standardline 35)
B20
Motor protection – winding monitoring
Motor protection – bearing monitoring
2 Pt100 screw-in resistance thermometers in basic circuit for rollingcontact bearings
A80
Motor protection – other monitoring functions
Leakage water detection
H08
–
–
✓ ✓
–
CMS2000 condition monitoring
systems 29) 30)
M49
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Subsequently rotatable main
terminal box 9)
J12
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Two-part plate on terminal box 1) 10)
K06
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Larger terminal box 1XB1 631 1) 9) 31) L00
–
–
–
✓ ✓
–
–
–
Undrilled entry plate
L01
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Larger terminal box 1XB1 621 1) 9)
M58
–
–
–
✓ ✓
–
–
–
Larger terminal box 1XB7 731
M70
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Larger terminal box 1XB7 740 9)
M71
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
PE connection without cable lug
Q00
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
–
–
–
–
Motor connection – terminal box
–
–
–
–
–
–
11
–
–
For legends and footnotes, see Page 11/32.
Siemens D 81.8 · 04/2014
11/7
© Siemens AG 2014
Article No. supplements and special versions
Options
Motors without explosion protection
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled,
enclosed version
7
8
Water-cooled
version
9
Air-cooled,
open version
with selfventilation
with forcedair cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forcedair cooling
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
Motor connection – terminal box – cable entry
Cable entry from right-hand 9)
L51
 
 
 
 
 
 
Cable entry from left-hand 9)
L52
 
 
 
 
 
 
9)
L61
 
 
 
 
 
 
Cable entry from NDE 9)
L62
 
 
 
 
 
 
Cable entry from the bottom 9)
L63
 
 
 
 
 
 
Cable entry from the top 9)
N83
 
 
 
 
 
 
Cable entry from DE
Motor connection – auxiliary terminal box
DIN 89280 cable gland, maximum
configuration 8)
K57
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
6 cables protruding, 1.5 m long 1)
L48
–
–
–
–
O. O.
R. R.
–
–
–
–
–
–
6 cables protruding, 3 m long 1)
L49
–
–
–
–
O. O.
R. R.
–
–
–
–
–
–
Auxiliary terminal box 1XB3020
L97
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Auxiliary terminal box 1XB9016
(cast-iron) 29) 30)
M50
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Auxiliary terminal box 1XB9015
(stainless steel) 29) 30)
M51
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Auxiliary terminal box 1XB9014
(aluminum) 29) 30)
M88
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Anti-condensation heating for 230 V
K45
✓ ✓
✓ ✓
✓ ✓
✓ ✓
–
–
–
–
Anti-condensation heating for 115 V
K46
✓ ✓
✓ ✓
✓ ✓
✓ ✓
–
–
–
–
Anti-condensation heating for 400 V
L08
✓ ✓
✓ ✓
✓ ✓
✓ ✓
–
–
–
–
Anti-condensation heating for 500 V 2) L09
✓ ✓
✓ ✓
✓ ✓
✓ ✓
–
–
–
–
Anti-condensation heating
Winding modification
11
Standard winding; non-standard
voltage 3)
M1Y
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Non-standard winding 3)
M2Y
–
–
–
–
–
–
Non-standard rated
speed 32)
N1Y
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Design with 2 galvanically separated C21
windings for operation with converter
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
–
–
–
–
–
–
2)
Ventilation
Filter for self-ventilation
G13
✓ ✓
–
–
–
–
–
–
✓ ✓
–
Filter for forced ventilation 16)
G12
–
✓ ✓
–
–
–
–
–
✓ ✓
Metal external fan
K35
✓ ✓
–
–
–
–
–
✓ ✓
–
Separately driven fan with
non-standard voltage 3) 16)
Y81
–
O. O.
R. R.
–
–
O. O.
R. R.
–
O. O.
R. R.
For legends and footnotes, see Page 11/32.
11/8
Siemens D 81.8 · 04/2014
–
–
–
–
–
–
–
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
1L .1. . . - . . . . . - . . . . -Z
315
Frame size
© Siemens AG 2014
Article No. supplements and special versions
Options
Motors without explosion protection
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled,
enclosed version
7
8
Water-cooled
version
9
Air-cooled,
open version
with selfventilation
with forcedair cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forcedair cooling
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
1L .1. . . - . . . . . - . . . . -Z
315
Frame size
Bearings and lubrication
Measuring nipple for SPM shock
pulse measurement for bearing
inspection 15)
G50
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Shock pulse measurement, fixed
sensor and distributor box
H05
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Shock pulse measurement,
complete alarm box
H07
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Prepared for mounting of a
vibration sensor SIPLUS
CMS2000 VIB-SENSOR S01 15)
H69
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Bearing design for increased
cantilever forces 18) 20)
K20
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Spent grease removal
K41
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Automatic re-lubricating device
EasyMatic 12)
N30
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Automatic re-lubricating device
STAR Control TIME M120 12)
N31
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Automatic re-lubricating device
STAR Control Impuls L250 12)
N32
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Vibration quantity level B 5) 21) 22)
K02
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Full-key balancing
L68
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
K16
✓ ✓
–
–
✓ ✓
–
–
✓ ✓
–
Shaft extension with standard
dimensions, without feather keyway
K42
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Non-standard cylindrical shaft
extension
Y55 • and
identification code
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Anti-clockwise direction,
unidirectional fan 42)
K98
–
✓
–
–
–
–
–
–
–
✓
–
–
Both directions of rotation 42)
K99
–
O.
R.
–
–
–
–
–
–
–
O.
R.
–
–
IP65 degree of protection 20)
K50
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
–
–
–
–
IP56 degree of protection
(non-heavy-sea) 16) 20)
K52
✓ ✓
–
✓ ✓
✓ ✓
–
–
–
–
Pipe connection without socket on
NDE from right-hand 27)
K77
–
–
O. O.
R. R.
–
–
–
–
–
–
O. O.
R. R.
Pipe connection without socket on
NDE from left-hand 27)
K78
–
–
O. O.
R. R.
–
–
–
–
–
–
O. O.
R. R.
Pipe connection without socket on
NDE from top 27)
K79
–
–
O. O.
R. R.
–
–
–
–
–
–
O. O.
R. R.
Balance and vibration quantity
Shaft
Second standard shaft extension
–
14) 39) 40)
11
Direction of rotation
Degrees of protection
–
Pipe connection
For legends and footnotes, see Page 11/32.
Siemens D 81.8 · 04/2014
11/9
© Siemens AG 2014
Article No. supplements and special versions
Options
Motors without explosion protection
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled,
enclosed version
7
8
Water-cooled
version
9
Air-cooled,
open version
with selfventilation
with forcedair cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forcedair cooling
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
–
–
–
✓ ✓
–
–
–
–
–
–
Water connection from top
K61
–
–
–
–
✓ ✓
–
–
–
–
–
–
Water connection from right-hand
(view from DE)
K62
–
–
–
–
✓ ✓
–
–
–
–
–
–
Water connection from left-hand
(view from DE)
K63
–
–
–
–
✓ ✓
–
–
–
–
–
–
Mounting a coupling provided 5) 19)
L17
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Motor mounting material for mounting on steel foundation 25)
L31
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Rust-resistant screws (externally) 28) M27
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Flange version A660 instead of
standard version 24)
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
 
 
 
 
 
 
Mechanical options
M61
Colors and paint finish
Standard finish in RAL 7030
stone gray
11
Unpainted (only cast-iron parts
primed)
K23
 
 
 
 
 
 
Special finish in RAL 7030
stone gray
K26
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Standard finish in other colors
Y53 • and
standard
finish in
RAL ….
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Special finish in other colors
Y54 • and
special
finish in
RAL ….
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Second rating plate, loose
K31
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Extra rating plate with identification
codes
Y82 • and
identification code
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Temperature class 180 (H), used
acc. to 155 (F) 1)
C14
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Temperature class 180 (H), used
acc. to 130 (B) 2)
C10
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Rating plate and extra rating plates
Utilization
Coolant temperature and site altitude
Coolant temperature
–50 to +40 °C
D02
O. O.
R. R.
O. O.
R. R.
–
–
–
–
–
–
–
–
Coolant temperature
–40 to +40 °C
D03
O. O.
R. R.
O. O.
R. R.
–
–
–
–
–
–
–
–
Coolant temperature
–30 to +40 °C
D04
✓ ✓
✓ ✓
–
–
–
–
–
–
–
–
Site altitude up to 2000 m above
sea level
D07
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Site altitude up to 3000 m above
sea level
D09
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
For legends and footnotes, see Page 11/32.
11/10
Siemens D 81.8 · 04/2014
455
355
–
Water connection and material
400
315
455
355
400
315
455
355
400
315
455
400
355
315
455
355
400
315
455
355
Cooling water pipes in stainless steel M85
instead of copper
1L .1. . . - . . . . . - . . . . -Z
400
315
Frame size
© Siemens AG 2014
Article No. supplements and special versions
Options
Motors without explosion protection
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled,
enclosed version
7
8
Water-cooled
version
9
Air-cooled,
open version
with selfventilation
with forcedair cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forcedair cooling
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
 
 
–
–
–
–
 
 
D12
 
 
–
–
–
–
 
 
Coolant temperature 55 °C
D13
 
 
–
–
–
–
 
 
Coolant temperature 60 °C
D14
O. O.
R. R.
O. O.
R. R.
–
–
–
–
O. O.
R. R.
O. O.
R. R.
Cooling water temperature 30 °C
D15
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Cooling water temperature 35 °C
D16
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Cooling water temperature 40 °C
D17
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Increased air humidity/temperature
with 30 to 60 g water per m3 of air
C19
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Increased air humidity/temperature
with 60 to 100 g water per m3 of air
C26
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Outdoor use with high salinity or
areas with almost continuous
condensation (corrosivity grade
C5-M/ C5-I)
E81
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Outdoor use with moderate salinity
(corrosivity grade C4)
E82
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Outdoor use with low salinity
(corrosivity grade C3)
E83
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
455
D11
Coolant temperature 50 °C
400
355
315
455
400
355
315
455
355
400
315
455
355
400
315
455
400
355
315
455
400
355
Coolant temperature 45 °C
1L .1. . . - . . . . . - . . . . -Z
315
Frame size
Coolant temperature and site altitude (continued)
Special ambient conditions
Design in accordance with standards and specifications
Electrical according to
NEMA MG1-12
D30
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Design according to UL
with "Recognition Mark"
D31
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Canadian regulations (CSA)
D40
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
VIK version
K30
✓ ✓
✓ ✓
✓ ✓
✓ ✓
–
–
Mounting of LL 861 900 222 with
Advanced Diagnostic System 2) 38)
H16
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Mounting of LL 861 900 220 2) 38)
–
–
11
Special technology – encoders
H70
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
2) 38)
H73
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Mounting of HOG 10 DN 2048 2) 38)
H83
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Mounting of HOG 11 DN 2048 2) 38)
H84
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Mounting of HOG 11 DN 1024 I
(16 mm) with special anti-corrosion
protection 2) 38)
H88
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Mounting of HOG 10 DN 1024 I with N06
terminal box/protection against dust
(zero signal) 2) 38)
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Mounting of HOG 10 D 1024 I with
terminal box/protection against
humidity 2) 38)
N07
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Mounting of HOG 10 DN 1024 I with N08
terminal box/protection against
humidity (zero signal) 2) 38)
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Mounting of HOG 10 D 1024 I
Mounting of HOG 10 D 1024 I with
N05
terminal box/protection against dust
2) 38)
For legends and footnotes, see Page 11/32.
Siemens D 81.8 · 04/2014
11/11
© Siemens AG 2014
Article No. supplements and special versions
Options
Motors without explosion protection
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled,
enclosed version
7
8
Water-cooled
version
9
Air-cooled,
open version
with selfventilation
with forcedair cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forcedair cooling
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
Special technology – encoders (continued)
Mounting of a special type of
encoder
Y70 • and
encoder
designation
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Mounting of HOG 10 DN 1024 I +
centrifugal switch (speed .... rpm),
terminal box protection against
humidity
Y74 • and
required
speed
.... rpm
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Mounting of HOG 10 DN 1024 I +
Y76 • and
required
centrifugal switch (speed .... rpm),
terminal box protection against dust speed
.... rpm
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Special technology – prepared for encoder mounting
Prepared for mounting of
LL 861 900 220 2) 38)
H78
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Prepared for mounting of
HOG 10 D 1024 I 2) 38)
H80
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Mounting of brake
(incl. the brake from Stromag) 17)
H47
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Mounting of the holding brake
SFB 160, 1600 Nm, 230 V,
Pintsch-Bubenzer 17)
J48
O. –
R.
O. –
R.
O. –
R.
O. –
R.
O. –
R.
O. –
R.
Mounting of the holding brake
SFB 160 SH, 2100 Nm, 230 V,
Pintsch-Bubenzer 17)
J49
O. –
R.
O. –
R.
O. –
R.
O. –
R.
O. –
R.
O. –
R.
Mounting of the holding brake
SFB 160 H, 2500 Nm, 230 V,
Pintsch-Bubenzer 17)
J56
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
Mounting of the holding brake
SFB 250 SH, 3300 Nm, 230 V,
Pintsch-Bubenzer 17)
J57
–
O.
R.
–
O.
R.
–
O.
R.
–
O.
R.
–
O.
R.
–
O.
R.
Mounting of the holding brake
SFB 250 H, 4000 Nm, 230 V,
Pintsch-Bubenzer 17)
J58
–
O.
R.
–
O.
R.
–
O.
R.
–
O.
R.
–
O.
R.
–
O.
R.
Mounting of the holding brake
SFB 250 H, 4000 Nm, 400 V,
Pintsch-Bubenzer 17)
J59
–
–
–
–
–
–
–
–
–
–
–
–
Mounting of the holding brake
SFB 400 SH, 5200 Nm, 400 V,
Pintsch-Bubenzer 17)
J66
–
–
–
–
–
–
–
–
–
–
–
–
Mounting of the holding brake
SFB 400 H, 6300 Nm, 400 V,
Pintsch-Bubenzer 17)
J67
–
–
–
–
–
–
–
–
–
–
–
–
Mounting of the holding brake
SFB 630 SH, 8000 Nm, 400 V,
Pintsch-Bubenzer 17)
J68
–
–
–
–
–
–
–
–
–
–
–
–
Mounting of the holding brake
SFB 630 H, 10000 Nm, 400 V,
Pintsch-Bubenzer 17)
J69
–
–
–
–
–
–
–
–
–
–
–
–
Special technology – brakes
11
For legends and footnotes, see Page 11/32.
11/12
Siemens D 81.8 · 04/2014
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
1L .1. . . - . . . . . - . . . . -Z
315
Frame size
© Siemens AG 2014
Article No. supplements and special versions
Options
Motors without explosion protection
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled,
enclosed version
7
8
Water-cooled
version
9
Air-cooled,
open version
with selfventilation
with forcedair cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forcedair cooling
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
1L .1. . . - . . . . . - . . . . -Z
315
Frame size
Special technology – prepared for brake mounting
Prepared for mounting of the holding J06
brake SFB for shaft height 315 17)
O. –
R.
O. –
R.
O. –
R.
O. –
R.
O. –
R.
O. –
R.
Prepared for mounting of the holding J07
brake SFB for shaft height 355 17)
–
–
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Documentation
Printed German/English Operating
Instructions enclosed
B23
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Paintwork coat
thickness measurement protocol
B29
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Electrical data sheet
B31
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Order specific
dimension drawing
B32
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Standard test schedule B34
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Balancing report
B35
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Load characteristics
B37
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Recommended spare
parts
B38
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Production schedule:
Generated once
B43
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Production schedule:
Updated every two weeks
B44
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Production schedule:
Updated monthly
B45
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Order-specific test
schedule
B48
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Starting curve
(T = f(n); I = f(n)) 1)
B50
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Equivalent circuit diagram
B51
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Thermal torque limit
curve 2)
B52
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Thermally admissible
duty cycle 1)
B53
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Document – Dynamic foundation load B54
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
11
Documentation languages
Documentation Czech
D54
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Polish
D55
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Russian
D56
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Japanese
D57
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Danish
D62
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Rumanian
D71
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Italian
D72
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Finnish
D73
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Dutch
D74
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Turkish
D75
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation French
D77
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Spanish
D78
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Portuguese
D79
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
For legends and footnotes, see Page 11/32.
Siemens D 81.8 · 04/2014
11/13
© Siemens AG 2014
Article No. supplements and special versions
Options
Motors without explosion protection
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled,
enclosed version
7
8
Water-cooled
version
9
Air-cooled,
open version
with selfventilation
with forcedair cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forcedair cooling
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
Documentation languages (continued)
Documentation Bulgarian
D80
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Norwegian
D81
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Hungarian
D82
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Swedish
D83
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Chinese
D84
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Documentation Serbian
D91
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Extension of liability for defects by
Q80
12 months up to a total of 24 months
from initial shipment
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Extension of liability for defects by
Q81
18 months up to a total of 30 months
from initial shipment
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Extension of liability for defects by
Q82
24 months up to a total of 36 months
from initial shipment
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Extension of liability for defects by
Q83
30 months up to a total of 42 months
from initial shipment
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Extension of liability for defects by
Q84
36 months up to a total of 48 months
from initial shipment
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Extension of liability for defects by
Q85
48 months up to a total of 60 months
from initial shipment
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Extension of liability
Test certificates
11
Standard test (routine test),
with acceptance
F01
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Visual acceptance and report
handover, with acceptance
F03
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Temperature-rise test, without
acceptance 33)
F04
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Temperature-rise test, with
acceptance 33)
F05
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Recording of short-circuit character- F16
istic and determination of shortcircuit losses, without acceptance 33)
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Recording of short-circuit character- F17
istic and determination of shortcircuit losses, with acceptance 33)
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Recording of load characteristic (T-n F18
characteristic), without acceptance 33)
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Recording of load characteristic (T-n
characteristic), with acceptance 33)
F19
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Noise measurement in no-load
operation, no noise analysis,
without acceptance 33)
F28
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Noise measurement in no-load
operation, no noise analysis,
with acceptance 33)
F29
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Recording of current and torque
F34
curves with torque metering shaft dur1)
34)
ing starting, without acceptance
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
For legends and footnotes, see Page 11/32.
11/14
Siemens D 81.8 · 04/2014
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
1L .1. . . - . . . . . - . . . . -Z
315
Frame size
© Siemens AG 2014
Article No. supplements and special versions
Options
Motors without explosion protection
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled,
enclosed version
7
8
Water-cooled
version
9
Air-cooled,
open version
with selfventilation
with forcedair cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forcedair cooling
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
1L .1. . . - . . . . . - . . . . -Z
315
Frame size
Test certificates (continued)
F35
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
F52
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Measurement of locked-rotor
F53
torque and current, with acceptance
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Noise measurement in no-load
operation, with noise analysis,
without acceptance 33)
F62
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Noise measurement in no-load
operation, with noise analysis,
with acceptance 33)
F63
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Type test with heat run for horizontal F82
motors, without acceptance 33) 22)
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Type test with heat run for horizontal F83
motors, with acceptance 33) 22)
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Type test with heat run for vertical
motors, without acceptance 33) 23)
F92
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Type test with heat run for vertical
motors, with acceptance 33) 23)
F93
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
✓ ✓
Commissioning of the classification
society by Siemens
E88
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Commissioning of the classification
society by third party
E89
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Pump drive for sea water desalination plants certified according to
Lloyd's Register 16) 36)
E90
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Recording of current and torque
curves with torque metering shaft
during starting, with acceptance
1) 34)
Measurement of locked-rotor
torque and current, without
acceptance 1) 34)
1) 34)
Pump drives
11
Marine non-essential service – technical design
Design according to ABS for
non-essential service 16) 7)
X00
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to BV for
non-essential service 16) 7)
X01
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to CCS for
non-essential service 16) 7)
X02
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to DNV for
non-essential service 16) 7)
X03
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to GL for
non-essential service 16) 7)
X04
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to KR for
non-essential service 16) 7)
X05
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to LR for
non-essential service 16) 7)
X06
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
For legends and footnotes, see Page 11/32.
Siemens D 81.8 · 04/2014
11/15
© Siemens AG 2014
Article No. supplements and special versions
Options
Motors without explosion protection
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled,
enclosed version
7
8
Water-cooled
version
9
Air-cooled,
open version
with selfventilation
with forcedair cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forcedair cooling
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to BV for essential X11
service 16) 7)
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to CCS for
essential service 16) 7)
X12
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to DNV for
essential service 16) 7)
X13
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to GL for essential X14
service 16) 7)
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to KR for essential X15
service 16) 7)
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to LR for essential X16
service 16) 7)
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to ABS for
essential service 16) 7)
Marine essential service certification
11
Certification for the first motor
ordered according to ABS for
essential service 16)
J70
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to ABS for essential service 16)
J71
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the first motor
ordered according to BV for
essential service 16)
J72
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to BV for essential service 16)
J73
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the first motor
ordered according to CCS for
essential service 16)
J74
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to CCS for essential service 16)
J75
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the first motor
ordered according to DNV for
essential service 16)
J76
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to DNV for essential service 16)
J77
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the first motor
ordered according to GL for
essential service 16)
J78
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to GL for essential service 16)
J79
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the first motor
ordered according to KR for
essential service 16)
J80
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to KR for essential service 16)
J81
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
For legends and footnotes, see Page 11/32.
11/16
Siemens D 81.8 · 04/2014
455
355
–
Marine essential service – technical design
400
315
455
355
400
315
455
400
355
315
455
400
355
315
455
355
400
315
455
355
X10
1L .1. . . - . . . . . - . . . . -Z
400
315
Frame size
© Siemens AG 2014
Article No. supplements and special versions
Options
Motors without explosion protection
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled,
enclosed version
7
8
Water-cooled
version
9
Air-cooled,
open version
with selfventilation
with forcedair cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forcedair cooling
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to LR for essential service 16)
J83
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
X30
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional X31
motors ordered according to ABS for
essential service 16)
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the first motor ordered acX32
cording to BV for essential service 16)
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional
motors ordered according to BV for
essential service 16)
X33
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the first motor ordered
according to CCS for essential
service 16)
X34
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional X35
motors ordered according to CCS for
essential service 16)
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the first motor ordered
according to DNV for essential
service 16)
X36
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional X37
motors ordered according to DNV for
essential service 16)
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the first motor ordered acX38
cording to GL for essential service 16)
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional
motors ordered according to GL for
essential service 16)
X39
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the first motor ordered acX40
cording to KR for essential service 16)
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional
motors ordered according to KR for
essential service 16)
X41
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the first motor ordered ac- X42
cording to LR for essential service 16)
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional
motors ordered according to LR for
essential service 16)
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
455
355
–
400
315
455
355
400
315
455
400
355
315
455
400
355
315
455
355
400
315
455
355
Certification for the first motor
J82
ordered according to LR for essential
16)
service
1L .1. . . - . . . . . - . . . . -Z
400
315
Frame size
Marine essential service certification (continued)
Marine essential service – testing
Tests for the first motor ordered
according to ABS for essential
service 16)
X43
11
Marine essential service for propulsion – technical design
X20
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to BV for essential X21
service, propulsion 16) 7)
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to CCS for
essential service, propulsion 16) 7)
X22
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to DNV for
essential service, propulsion 16) 7)
X23
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to ABS for
essential service, propulsion 16) 7)
For legends and footnotes, see Page 11/32.
Siemens D 81.8 · 04/2014
11/17
© Siemens AG 2014
Article No. supplements and special versions
Options
Motors without explosion protection
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled,
enclosed version
7
8
Water-cooled
version
9
Air-cooled,
open version
with selfventilation
with forcedair cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forcedair cooling
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to KR for essential X25
service, propulsion 16) 7)
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Design according to LR for essential X26
service, propulsion 16) 7)
–
–
–
–
✓ ✓
✓ ✓
–
–
–
–
Marine essential service for propulsion – certification
11
Certification for the first motor
ordered according to ABS for
essential service, propulsion 16)
N40
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to ABS for essential service,
propulsion 16)
N41
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the first motor
ordered according to BV for
essential service, propulsion 16)
N42
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to BV for essential service,
propulsion 16)
N43
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the first motor
ordered according to CCS for
essential service, propulsion 16)
N44
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to CCS for essential service,
propulsion 16)
N45
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the first motor
ordered according to DNV for
essential service, propulsion 16)
N46
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to DNV for essential service,
propulsion 16)
N47
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the first motor
ordered according to GL for essential service, propulsion 16)
N48
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to GL for essential service,
propulsion 16)
N49
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the first motor
ordered according to KR for
essential service, propulsion 16)
N50
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to KR for essential service,
propulsion 16)
N51
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the first motor
N52
ordered according to LR for essential
16)
service, propulsion
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Certification for the second and
additional motors ordered according to LR for essential service,
propulsion 16)
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
N53
For legends and footnotes, see Page 11/32.
11/18
Siemens D 81.8 · 04/2014
455
355
–
Marine essential service for propulsion – technical design (continued)
400
315
455
355
400
315
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
Design according to GL for essential X24
service, propulsion 16) 7)
1L .1. . . - . . . . . - . . . . -Z
315
Frame size
© Siemens AG 2014
Article No. supplements and special versions
Options
Motors without explosion protection
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled,
enclosed version
7
8
Water-cooled
version
9
Air-cooled,
open version
with selfventilation
with forcedair cooling
with waterjacket cooling
with heat
exchanger
with selfventilation
with forcedair cooling
1LM1
1LQ1
1LH1
1LN1
1LL1
1LP1
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional
motors ordered according to ABS
for essential service, propulsion 16)
X61
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the first motor ordered
according to BV for essential
service, propulsion 16)
X62
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional
motors ordered according to BV
for essential service, propulsion 16)
X63
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the first motor ordered
according to CCS for essential
service, propulsion 16)
X64
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional
motors ordered according to CCS
for essential service, propulsion 16)
X65
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the first motor ordered
according to DNV for essential
service, propulsion 16)
X66
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional
motors ordered according to DNV
for essential service, propulsion 16)
X67
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the first motor ordered
according to GL for essential
service, propulsion 16)
X68
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional
motors ordered according to GL
for essential service, propulsion 16)
X69
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the first motor ordered
according to KR for essential
service, propulsion 16)
X70
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional
motors ordered according to KR
for essential service, propulsion 16)
X71
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the first motor ordered
X72
according to LR for essential service,
16)
propulsion
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
Tests for the second and additional
motors ordered according to LR
for essential service, propulsion 16)
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
O. O.
R. R.
O. O.
R. R.
–
–
–
–
O. O.
R. R.
O. O.
R. R.
O. O.
R. R.
455
355
X60
400
315
455
355
400
315
455
400
355
315
455
400
355
315
455
355
400
315
455
355
Tests for the first motor ordered
according to ABS for essential
service, propulsion 16)
1L .1. . . - . . . . . - . . . . -Z
400
315
Frame size
Marine essential service for propulsion – testing
X73
11
Marine – Additional options for essential service and essential service for propulsion
Motor for ship application, with
higher ambient temperature and/
or use of temperature class 180 (H)
utilized according to 130 (B) 16)
E80
–
–
Tests in the presence of representatives of the customer (in addition to
the inspector of the classification
society)
X99
O. O.
R. R.
–
–
O. O.
R. R.
O. O.
R. R.
For legends and footnotes, see Page 11/32.
Siemens D 81.8 · 04/2014
11/19
© Siemens AG 2014
Article No. supplements and special versions
Options
Explosion-proof motors
■ Selection and ordering data
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled, enclosed version
7
Water-cooled version
with selfventilation
with forced-air
cooling
with waterjacket cooling
with heat exchanger
1MM1
1MQ1
1MH1
1MN1
Motor protection – winding monitoring
6 PTC thermistors for alarm and
A12
tripping, without lightning arresters 6)
✓
✓
✓
✓
✓
✓
✓
✓
2 temperature sensors KTY 84-130
A25








6 temperature sensors KTY 84-130
A27
✓
✓
✓
✓
✓
✓
✓
✓
6 Pt100 resistance thermometers 6)
A61
✓
✓
✓
✓
✓
✓
✓
✓
6 Pt100 resistance thermometers,
3-wire circuit from auxiliary terminal
box (option M50 or M88) 6)
A64
✓
✓
✓
✓
✓
✓
✓
✓
Motor protection – bearing monitoring
2 Pt100 screw-in resistance
thermometers in basic circuit for
rolling-contact bearings
A72
✓
✓
✓
✓
✓
✓
✓
✓
2 Pt100 screw-in resistance
thermometers in basic circuit for
rolling-contact bearings, 3-wire
circuit from auxiliary terminal box
A78
✓
✓
✓
✓
✓
✓
✓
✓
2 Pt100 double screw-in resistance
thermometers in 3-wire circuit for
rolling-contact bearings
A80
✓
✓
✓
✓
✓
✓
✓
✓
H08
–
–
–
–
–
–
✓
✓
Subsequently rotatable main
terminal box 9)
J12
✓
✓
✓
✓
✓
✓
✓
✓
Larger terminal box 1XB1 631
L00
–
–
–
–
✓
✓
–
–
Undrilled entry plate
L01
✓
✓
✓
✓
✓
✓
✓
✓
Larger terminal box 1XB1 6211) 9)
M58
–
–
–
–
✓
✓
–
–
PE connection without cable lug
Q00
✓
✓
✓
✓
✓
✓
✓
✓
Motor protection – other monitoring functions
Leakage water detection
Motor connection – terminal box
1) 9) 31)
11
Motor connection – terminal box – cable entry
Cable entry from right-hand 9)
L51








Cable entry from left-hand 9)
L52








9)
L61








Cable entry from NDE 9)
L62








Cable entry from the bottom 9)
L63








Cable entry from the top 9)
N83








Cable entry from DE
For legends and footnotes, see Page 11/32.
11/20
Siemens D 81.8 · 04/2014
455
400
355
315
455
400
355
315
455
400
355
315
455
400
1M .1. . . - . . . . . - . . . . -Z
355
315
Frame size
© Siemens AG 2014
Article No. supplements and special versions
Options
Explosion-proof motors
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled, enclosed version
7
Water-cooled version
with selfventilation
with forced-air
cooling
with waterjacket cooling
with heat exchanger
1MM1
1MQ1
1MH1
1MN1
455
400
355
315
455
400
355
315
455
400
355
315
455
400
1M .1. . . - . . . . . - . . . . -Z
355
315
Frame size
Motor connection – auxiliary terminal box
DIN 89280 cable gland, maximum
configuration 8)
K57
✓
✓
✓
✓
✓
✓
✓
✓
6 cables protruding, 1.5 m long 1)
L48
–
–
–
–
O.
R.
O.
R.
–
–
6 cables protruding, 3 m long 1)
L49
–
–
–
–
O.
R.
O.
R.
–
–
Auxiliary terminal box 1XB3020
L97
✓
✓
✓
✓
✓
✓
✓
✓
Auxiliary terminal box 1XB9016
(cast-iron) 29) 30)
M50
✓
✓
✓
✓
✓
✓
✓
✓
Auxiliary terminal box 1XB9015
(stainless steel) 29) 30)
M51
✓
✓
✓
✓
✓
✓
✓
✓
Auxiliary terminal box 1XB9014
(aluminum) 29) 30)
M88
✓
✓
✓
✓
✓
✓
✓
✓
Anti-condensation heating for 230 V
K45
✓
✓
✓
✓
✓
✓
✓
✓
Anti-condensation heating for 115 V
K46
✓
✓
✓
✓
✓
✓
✓
✓
Anti-condensation heating for 400 V
L08
✓
✓
✓
✓
✓
✓
✓
✓
Anti-condensation heating for 500 V
L09
✓
✓
✓
✓
✓
✓
✓
✓
Standard winding; non-standard
voltage 3)
M1Y
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Non-standard winding 3)
M2Y
–
–
–
–
–
–
–
–
Non-standard rated speed 32)
N1Y
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Design with 2 galvanically separated C21
windings for operation with converter
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Anti-condensation heating
2)
Winding modification
2)
Ventilation
Metal external fan
K35
✓
✓
–
–
–
–
–
–
Separately driven fan with
non-standard voltage 3) 16)
Y81
–
–
O.
R.
O.
R.
–
–
O.
R.
O.
R.
Measuring nipple for SPM shock
pulse measurement for bearing
inspection 15)
G50
✓
✓
✓
✓
✓
✓
✓
✓
Shock pulse measurement, fixed
sensor and distributor box
H05
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Shock pulse measurement,
complete alarm box
H07
✓
✓
✓
✓
✓
✓
✓
✓
Prepared for mounting of a
vibration sensor SIPLUS
CMS2000 VIB-SENSOR S01 15)
H69
✓
✓
✓
✓
✓
✓
✓
✓
Bearing design for increased
cantilever forces 18) 20)
K20
✓
✓
✓
✓
✓
✓
✓
✓
Spent grease removal
K41
✓
✓
✓
✓
✓
✓
✓
✓
11
Bearings and lubrication
For legends and footnotes, see Page 11/32.
Siemens D 81.8 · 04/2014
11/21
© Siemens AG 2014
Article No. supplements and special versions
Options
Explosion-proof motors
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled, enclosed version
7
Water-cooled version
with selfventilation
with forced-air
cooling
with waterjacket cooling
with heat exchanger
1MM1
1MQ1
1MH1
1MN1
Balance and vibration quantity
Vibration quantity level B 5) 21) 22)
K02
✓
✓
✓
✓
✓
✓
✓
✓
Full-key balancing
L68
✓
✓
✓
✓
✓
✓
✓
✓
K16
✓
✓
–
–
✓
✓
–
–
Shaft extension with standard
dimensions, without feather keyway
K42
✓
✓
✓
✓
✓
✓
✓
✓
Non-standard cylindrical shaft
extension
Y55 • and
identification code
–
–
–
–
–
–
–
–
Anti-clockwise direction, unidirectional fan 42)
K98
–
✓
–
–
–
–
–
–
Both directions of rotation 42)
K99
–
O.
R.
–
–
–
–
–
–
IP65 degree of protection 20)
K50
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
IP56 degree of protection (nonheavy-sea) 16) 20)
K52
✓
✓
–
–
✓
✓
✓
✓
Pipe connection without socket on
NDE from right-hand 27)
K77
–
–
O.
R.
O.
R.
–
–
–
–
Pipe connection without socket on
NDE from left-hand 27)
K78
–
–
O.
R.
O.
R.
–
–
–
–
Pipe connection without socket on
NDE from top 27)
K79
–
–
O.
R.
O.
R.
–
–
–
–
Cooling water pipes in stainless steel M85
instead of copper
–
–
–
–
✓
✓
–
–
Water connection from top
K61
–
–
–
–
✓
✓
–
–
Water connection from right-hand
(view from DE)
K62
–
–
–
–
✓
✓
–
–
Water connection from left-hand
(view from DE)
K63
–
–
–
–
✓
✓
–
–
Mounting a coupling provided 5) 19)
L17
✓
✓
✓
✓
✓
✓
✓
✓
Motor mounting material for mounting on steel foundation 25)
L31
✓
✓
✓
✓
✓
✓
✓
✓
Rust-resistant screws (externally) 28) M27
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Flange version A660 instead of
standard version 24)
✓
✓
✓
✓
✓
✓
✓
✓
Shaft
Second standard shaft extension
14) 39) 40)
Direction of rotation
Degrees of protection
Pipe connection
Water connection and material
11
Mechanical options
M61
For legends and footnotes, see Page 11/32.
11/22
Siemens D 81.8 · 04/2014
455
400
355
315
455
400
355
315
455
400
355
315
455
400
1M .1. . . - . . . . . - . . . . -Z
355
315
Frame size
© Siemens AG 2014
Article No. supplements and special versions
Options
Explosion-proof motors
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled, enclosed version
7
Water-cooled version
with selfventilation
with forced-air
cooling
with waterjacket cooling
with heat exchanger
1MM1
1MQ1
1MH1
1MN1
455
400
355
315
455
400
355
315
455
400
355
315
455
400
1M .1. . . - . . . . . - . . . . -Z
355
315
Frame size
Colors and paint finish
Standard finish in RAL 7030
stone gray








Unpainted (only cast-iron parts
primed)
K23








Special finish in RAL 7030
stone gray
K26
✓
✓
✓
✓
✓
✓
✓
✓
Standard finish in other colors
Y53 • and
standard
finish in
RAL ….
–
–
–
–
–
–
–
–
Special finish in other colors
Y54 • and
special
finish in
RAL ….
–
–
–
–
–
–
–
–
Second rating plate, loose
K31
✓
✓
✓
✓
✓
✓
✓
✓
Extra rating plate with identification
codes
Y82 • and
identification code
–
–
–
–
–
–
–
–
C10
✓
✓
✓
✓
✓
✓
✓
✓
Rating plate and extra rating plates
Utilization
Temperature class 180 (H), used
acc. to 130 (B) 2)
Coolant temperature and site altitude
Increased air humidity/temperature
with 30 to 60 g water per m3 of air
C19
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Increased air humidity/temperature
with 60 to 100 g water per m3 of air
C26
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Coolant temperature
–50 to +40 °C
D02
O.
R.
O.
R.
O.
R.
O.
R.
–
–
–
–
Coolant temperature
–40 to +40 °C
D03
O.
R.
O.
R.
O.
R.
O.
R.
–
–
–
–
Coolant temperature
–30 to +40 °C
D04
✓
✓
✓
✓
–
–
–
–
Coolant temperature 45 °C
D11




–
–
–
–
Coolant temperature 50 °C
D12




–
–
–
–
Coolant temperature 55 °C
D13




–
–
–
–
Coolant temperature 60 °C
D14
O.
R.
O.
R.
O.
R.
O.
R.
–
–
–
–
Cooling water temperature 30 °C
D15
–
–
–
–
✓
✓
✓
✓
Cooling water temperature 35 °C
D16
–
–
–
–
✓
✓
✓
✓
Cooling water temperature 40 °C
D17
–
–
–
–
✓
✓
✓
✓
Outdoor use with high salinity or
areas with almost continuous
condensation (corrosivity grade
C5-M/ C5-I)
E81
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Outdoor use with moderate salinity
(corrosivity grade C4)
E82
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Outdoor use with moderate salinity
(corrosivity grade C3)
E83
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
11
For legends and footnotes, see Page 11/32.
Siemens D 81.8 · 04/2014
11/23
© Siemens AG 2014
Article No. supplements and special versions
Options
Explosion-proof motors
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled, enclosed version
7
Water-cooled version
with selfventilation
with forced-air
cooling
with waterjacket cooling
with heat exchanger
1MM1
1MQ1
1MH1
1MN1
Design in accordance with standards and specifications
✓
✓
✓
✓
✓
✓
✓
✓
Conformity statement in accordance D36
with 94/9/EG (ATEX) of an independent body for Zone 2 motors
(Ex nA)16) 41)
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
IEC Ex certificate – only in combina- D37
tion with order codes M72 and M73
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Electrical according to
NEMA MG1-12
D30
16) 41)
Design according to ATEX, IEC-Ex
Square load curve M ~ n2 4) 16) *)
B60
✓
✓
✓
✓
✓
✓
✓
✓
Constant load curve T = const 4) 16)
B61
–
–
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Ex nA II on VIK rating plate 11) 26)
C27
✓
✓
✓
✓
✓
✓
✓
✓
VIK version 37)
K30
✓
✓
✓
✓
✓
✓
✓
✓
Design for Zone 22 for non-conductive dust (IP55) for mains-fed
operation 1)
M35
–
–
–
–
✓
✓
–
–
Design for Zone 22 for non-conductive dust (IP55) for converter-fed
operation 2) 13) 16)
M39
✓
✓
✓
✓
✓
✓
✓
✓
Design for Zone 2 for mains-fed
operation Ex nA II T3 according to
IEC/EN 60079-15 1)
M72
–
–
–
–
✓
✓
–
–
Design for Zone 2 for converter-fed
operation Ex nA II T3 according to
IEC/EN 60079-15 2) 13) 16)
M73
✓
✓
✓
✓
✓
✓
✓
✓
Mounting of HOG 10 D 1024 I 2) 38)
H73
✓
✓
✓
✓
✓
✓
✓
✓
Mounting of HOG 10 DN 2048 2) 38)
H83
✓
✓
✓
✓
✓
✓
✓
✓
Mounting of HOG 11 DN 2048 2) 38)
H84
✓
✓
✓
✓
✓
✓
✓
✓
Mounting of HOG 11 DN 1024 I
(16 mm) with special anti-corrosion
protection 2) 38)
H88
✓
✓
✓
✓
✓
✓
✓
✓
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Mounting of HOG 10 DN 1024 I with N06
terminal box/protection against dust
(zero signal) 2) 38)
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Mounting of HOG 10 D 1024 I with
terminal box/protection against
humidity 2) 38)
N07
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Mounting of HOG 10 DN 1024 I with N08
terminal box/protection against dust
(zero signal) 2) 38)
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Mounting of a special type of
encoder
–
–
–
–
–
–
–
–
Special technology – encoders
11
Mounting of HOG 10 D 1024 I with
N05
terminal box/protection against dust
2) 38)
Y70 • and
encoder
designation
For legends and footnotes, see Page 11/32.
11/24
Siemens D 81.8 · 04/2014
455
400
355
315
455
400
355
315
455
400
355
315
455
400
1M .1. . . - . . . . . - . . . . -Z
355
315
Frame size
© Siemens AG 2014
Article No. supplements and special versions
Options
Explosion-proof motors
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled, enclosed version
7
Water-cooled version
with selfventilation
with forced-air
cooling
with waterjacket cooling
with heat exchanger
1MM1
1MQ1
1MH1
1MN1
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
1M .1. . . - . . . . . - . . . . -Z
315
Frame size
Special technology – prepared for encoder mounting
Prepared for mounting of
LL 861 900 220 2) 38)
H78
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Prepared for mounting of
HOG 10 D 1024 I 2) 38)
H80
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
Printed German/English Operating
Instructions enclosed
B23
✓
✓
✓
✓
✓
✓
✓
✓
Document – Paintwork coat
thickness measurement protocol
B29
✓
✓
✓
✓
✓
✓
✓
✓
Document – Electrical data sheet
B31
✓
✓
✓
✓
✓
✓
✓
✓
Document – Order specific
dimension drawing
B32
✓
✓
✓
✓
✓
✓
✓
✓
Document – Standard test schedule B34
✓
✓
✓
✓
✓
✓
✓
✓
Document – Balancing report
B35
✓
✓
✓
✓
✓
✓
✓
✓
Document – Load characteristics
B37
✓
✓
✓
✓
✓
✓
✓
✓
Document – Recommended spare
parts
B38
✓
✓
✓
✓
✓
✓
✓
✓
Document – Production schedule:
Generated once
B43
✓
✓
✓
✓
✓
✓
✓
✓
Document – Production schedule:
Updated every two weeks
B44
✓
✓
✓
✓
✓
✓
✓
✓
Document – Production schedule:
Updated monthly
B45
✓
✓
✓
✓
✓
✓
✓
✓
Document – Order-specific test
schedule
B48
✓
✓
✓
✓
✓
✓
✓
✓
Document – Starting curve
(T = f(n); I = f(n)) 1)
B50
✓
✓
✓
✓
✓
✓
✓
✓
Document – Equivalent circuit
diagram
B51
✓
✓
✓
✓
✓
✓
✓
✓
Document – Thermal torque limit
curve 2)
B52
✓
✓
✓
✓
✓
✓
✓
✓
Document – Thermally admissible
duty cycle 1)
B53
✓
✓
✓
✓
✓
✓
✓
✓
Document – Dynamic foundation
load
B54
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Czech
D54
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Polish
D55
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Russian
D56
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Japanese
D57
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Danish
D62
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Rumanian
D71
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Italian
D72
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Finnish
D73
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Dutch
D74
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Turkish
D75
✓
✓
✓
✓
✓
✓
✓
✓
Documentation French
D77
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Spanish
D78
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Portuguese
D79
✓
✓
✓
✓
✓
✓
✓
✓
Documentation
11
Documentation languages
For legends and footnotes, see Page 11/32.
Siemens D 81.8 · 04/2014
11/25
© Siemens AG 2014
Article No. supplements and special versions
Options
Explosion-proof motors
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled, enclosed version
7
Water-cooled version
with selfventilation
with forced-air
cooling
with waterjacket cooling
with heat exchanger
1MM1
1MQ1
1MH1
1MN1
Documentation languages (continued)
Documentation Bulgarian
D80
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Norwegian
D81
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Hungarian
D82
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Swedish
D83
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Chinese
D84
✓
✓
✓
✓
✓
✓
✓
✓
Documentation Serbian
D91
✓
✓
✓
✓
✓
✓
✓
✓
Q80
Extension of liability for defects by
12 months up to a total of 24 months
from initial shipment
✓
✓
✓
✓
✓
✓
✓
✓
Extension of liability for defects by
Q81
18 months up to a total of 30 months
from initial shipment
✓
✓
✓
✓
✓
✓
✓
✓
Extension of liability for defects by
Q82
24 months up to a total of 36 months
from initial shipment
✓
✓
✓
✓
✓
✓
✓
✓
Extension of liability for defects by
Q83
30 months up to a total of 42 months
from initial shipment
✓
✓
✓
✓
✓
✓
✓
✓
Extension of liability for defects by
Q84
36 months up to a total of 48 months
from initial shipment
✓
✓
✓
✓
✓
✓
✓
✓
Extension of liability for defects by
Q85
48 months up to a total of 60 months
from initial shipment
✓
✓
✓
✓
✓
✓
✓
✓
Extension of liability
Test certificates
11
Standard test (routine test), with
acceptance
F01
✓
✓
✓
✓
✓
✓
✓
✓
Visual acceptance and report
handover, with acceptance
F03
✓
✓
✓
✓
✓
✓
✓
✓
Temperature-rise test, without
acceptance 33)
F04
✓
✓
✓
✓
✓
✓
✓
✓
Temperature-rise test, with
acceptance 33)
F05
✓
✓
✓
✓
✓
✓
✓
✓
Recording of short-circuit character- F16
istic and determination of shortcircuit losses, without acceptance 33)
✓
✓
✓
✓
✓
✓
✓
✓
Recording of short-circuit character- F17
istic and determination of shortcircuit losses, with acceptance 33)
✓
✓
✓
✓
✓
✓
✓
✓
Recording of load characteristic (T-n F18
characteristic), without acceptance 33)
✓
✓
✓
✓
✓
✓
✓
✓
Recording of load characteristic (T-n
characteristic), with acceptance 33)
F19
✓
✓
✓
✓
✓
✓
✓
✓
Noise measurement in no-load
operation, no noise analysis,
without acceptance 33)
F28
✓
✓
✓
✓
✓
✓
✓
✓
Noise measurement in no-load
operation, no noise analysis,
with acceptance 33)
F29
✓
✓
✓
✓
✓
✓
✓
✓
Recording of current and torque
curves with torque metering shaft
during starting, without acceptance
F34
✓
✓
✓
✓
✓
✓
✓
✓
1) 34)
For legends and footnotes, see Page 11/32.
11/26
Siemens D 81.8 · 04/2014
455
400
355
315
455
400
355
315
455
400
355
315
455
400
355
1M .1. . . - . . . . . - . . . . -Z
315
Frame size
© Siemens AG 2014
Article No. supplements and special versions
Options
Explosion-proof motors
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled, enclosed version
7
Water-cooled version
with selfventilation
with forced-air
cooling
with waterjacket cooling
with heat exchanger
1MM1
1MQ1
1MH1
1MN1
455
400
355
315
455
400
355
315
455
400
355
315
455
400
1M .1. . . - . . . . . - . . . . -Z
355
315
Frame size
Test certificates (continued)
F35
✓
✓
✓
✓
✓
✓
✓
✓
F52
✓
✓
✓
✓
✓
✓
✓
✓
Measurement of locked-rotor torque
and current, with acceptance 1) 34)
F53
✓
✓
✓
✓
✓
✓
✓
✓
Noise measurement in no-load
operation, with noise analysis,
without acceptance 33)
F62
✓
✓
✓
✓
✓
✓
✓
✓
Noise measurement in no-load
operation, with noise analysis,
with acceptance 33)
F63
✓
✓
✓
✓
✓
✓
✓
✓
Type test with heat run for horizontal F82
motors, without acceptance 33) 22)
✓
✓
✓
✓
✓
✓
✓
✓
Type test with heat run for horizontal F83
motors, with acceptance 33) 22)
✓
✓
✓
✓
✓
✓
✓
✓
Type test with heat run for vertical
motors, without acceptance 33) 23)
F92
✓
✓
✓
✓
✓
✓
✓
✓
Type test with heat run for vertical
motors, with acceptance 33) 23)
F93
✓
✓
✓
✓
✓
✓
✓
✓
Commissioning of the classification
society by Siemens
E88
–
–
–
–
✓
✓
✓
✓
Commissioning of the classification
society by third party
E89
–
–
–
–
✓
✓
✓
✓
Pump drive for sea water desalination plants certified according to
Lloyd's Register 16) 36)
E90
–
–
–
–
✓
✓
✓
✓
Recording of current and torque
curves with torque metering shaft
during starting, with acceptance
1) 34)
Measurement of locked-rotor torque
and current, without acceptance
1) 34)
Pump drives
11
Marine non-essential service – technical design
Design according to ABS for
non-essential service 16) 7)
X00
–
–
–
–
✓
✓
✓
✓
Design according to BV for
non-essential service 16) 7)
X01
–
–
–
–
✓
✓
✓
✓
Design according to CCS for
non-essential service 16) 7)
X02
–
–
–
–
✓
✓
✓
✓
Design according to DNV for
non-essential service 16) 7)
X03
–
–
–
–
✓
✓
✓
✓
Design according to GL for
non-essential service 16) 7)
X04
–
–
–
–
✓
✓
✓
✓
Design according to KR for
non-essential service 16) 7)
X05
–
–
–
–
✓
✓
✓
✓
Design according to LR for
non-essential service 16) 7)
X06
–
–
–
–
✓
✓
✓
✓
Marine essential service – technical design
Design according to ABS for
essential service 16) 7)
X10
–
–
–
–
✓
✓
✓
✓
Design according to BV for
essential service 16) 7)
X11
–
–
–
–
✓
✓
✓
✓
Design according to CCS for
essential service 16) 7)
X12
–
–
–
–
✓
✓
✓
✓
For legends and footnotes, see Page 11/32.
Siemens D 81.8 · 04/2014
11/27
© Siemens AG 2014
Article No. supplements and special versions
Options
Explosion-proof motors
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled, enclosed version
7
Water-cooled version
with selfventilation
with forced-air
cooling
with waterjacket cooling
with heat exchanger
1MM1
1MQ1
1MH1
1MN1
Marine essential service – technical design (continued)
Design according to DNV for
essential service 16) 7)
X13
–
–
–
–
✓
✓
✓
✓
Design according to GL for
essential service 16) 7)
X14
–
–
–
–
✓
✓
✓
✓
Design according to KR for
essential service 16) 7)
X15
–
–
–
–
✓
✓
✓
✓
Design according to LR for
essential service 16) 7)
X16
–
–
–
–
✓
✓
✓
✓
Marine essential service – certification
11
Certification for the first motor
ordered according to ABS for
essential service16)
J70
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to ABS for essential service 16)
J71
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the first motor
ordered according to BV for
essential service16)
J72
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to BV for essential service 16)
J73
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the first motor
ordered according to CCS for
essential service 16)
J74
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to CCS for essential service 16)
J75
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the first motor
ordered according to DNV for
essential service 16)
J76
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to DNV for essential service 16)
J77
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the first motor
ordered according to GL for
essential service16)
J78
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to GL for essential service 16)
J79
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the first motor
ordered according to KR for
essential service16)
J80
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to KR for essential service 16)
J81
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the first motor
ordered according to LR for
essential service16)
J82
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to LR for essential service 16)
J83
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
For legends and footnotes, see Page 11/32.
11/28
Siemens D 81.8 · 04/2014
455
400
355
315
455
400
355
315
455
400
355
315
455
400
1M .1. . . - . . . . . - . . . . -Z
355
315
Frame size
© Siemens AG 2014
Article No. supplements and special versions
Options
Explosion-proof motors
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled, enclosed version
7
Water-cooled version
with selfventilation
with forced-air
cooling
with waterjacket cooling
with heat exchanger
1MM1
1MQ1
1MH1
1MN1
455
400
355
315
455
400
355
315
455
400
355
315
455
400
1M .1. . . - . . . . . - . . . . -Z
355
315
Frame size
Marine essential service – testing
Tests for the first motor ordered
according to ABS for essential
service 16)
X30
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the second and additional X31
motors ordered according to ABS for
essential service 16)
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the first motor ordered
X32
according to BV for essential service
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
16)
Tests for the second and additional
motors ordered according to BV for
essential service 16)
X33
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the first motor ordered
according to CCS for essential
service 16)
X34
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the second and additional
motors ordered according to CCS
for essential service 16)
X35
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the first motor ordered
according to DNV for essential
service 16)
X36
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the second and additional
motors ordered according to DNV
for essential service 16)
X37
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the first motor ordered acX38
cording to GL for essential service 16)
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the second and additional
motors ordered according to GL
for essential service 16)
X39
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the first motor ordered acX40
cording to KR for essential service 16)
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the second and additional
motors ordered according to KR for
essential service 16)
X41
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the first motor ordered
X42
according to LR for essential service
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
11
16)
Tests for the second and additional
motors ordered according to LR for
essential service 16)
X43
Marine essential service for propulsion – technical design
Design according to ABS for
essential service, propulsion 16) 7)
X20
–
–
–
–
✓
✓
✓
✓
Design according to BV for
essential service, propulsion 16) 7)
X21
–
–
–
–
✓
✓
✓
✓
Design according to CCS for
essential service, propulsion 16) 7)
X22
–
–
–
–
✓
✓
✓
✓
Design according to DNV for
essential service, propulsion 16) 7)
X23
–
–
–
–
✓
✓
✓
✓
Design according to GL for
essential service, propulsion 16) 7)
X24
–
–
–
–
✓
✓
✓
✓
Design according to KR for
essential service, propulsion 16) 7)
X25
–
–
–
–
✓
✓
✓
✓
Design according to LR for essential X26
service, propulsion 16) 7)
–
–
–
–
✓
✓
✓
✓
For legends and footnotes, see Page 11/32.
Siemens D 81.8 · 04/2014
11/29
© Siemens AG 2014
Article No. supplements and special versions
Options
Explosion-proof motors
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled, enclosed version
7
Water-cooled version
with selfventilation
with forced-air
cooling
with waterjacket cooling
with heat exchanger
1MM1
1MQ1
1MH1
1MN1
Marine essential service for propulsion – certification
11
Certification for the first motor
ordered according to ABS for
essential service, propulsion 16)
N40
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to ABS for essential service,
propulsion 16)
N41
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the first motor
ordered according to BV for
essential service, propulsion 16)
N42
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to BV for essential service,
propulsion 16)
N43
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the first motor
ordered according to CCS for
essential service, propulsion 16)
N44
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to CCS for essential service,
propulsion 16)
N45
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the first motor
ordered according to DNV for
essential service, propulsion 16)
N46
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to DNV for essential service,
propulsion 16)
N47
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the first motor
ordered according to GL for
essential service, propulsion 16)
N48
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to GL for essential service,
propulsion 16)
N49
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the first motor
ordered according to KR for
essential service, propulsion 16)
N50
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to KR for essential service,
propulsion 16)
N51
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the first motor
ordered according to LR for
essential service, propulsion 16)
N52
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Certification for the second and
additional motors ordered according to LR for essential service,
propulsion 16)
N53
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Marine essential service for propulsion
Tests for the first motor ordered
according to ABS for essential
service, propulsion 16)
X60
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the second and additional
motors ordered according to ABS
for essential service, propulsion 16)
X61
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the first motor ordered
according to BV for essential
service, propulsion 16)
X62
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
For legends and footnotes, see Page 11/32.
11/30
Siemens D 81.8 · 04/2014
455
400
355
315
455
400
355
315
455
400
355
315
455
400
1M .1. . . - . . . . . - . . . . -Z
355
315
Frame size
© Siemens AG 2014
Article No. supplements and special versions
Options
Explosion-proof motors
Special versions
Additional
identification
code -Z with
order code
and plain text
if required
Catalog section
4
5
6
Air-cooled, enclosed version
7
Water-cooled version
with selfventilation
with forced-air
cooling
with waterjacket cooling
with heat exchanger
1MM1
1MQ1
1MH1
1MN1
455
400
355
315
455
400
355
315
455
400
355
315
455
400
1M .1. . . - . . . . . - . . . . -Z
355
315
Frame size
Marine essential service for propulsion (continued)
Tests for the second and additional
motors ordered according to BV
for essential service, propulsion 16)
X63
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the first motor ordered
according to CCS for essential
service, propulsion 16)
X64
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the second and additional
motors ordered according to CCS
for essential service, propulsion 16)
X65
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the first motor ordered
according to DNV for essential
service, propulsion 16)
X66
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the second and additional
motors ordered according to DNV
for essential service, propulsion 16)
X67
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the first motor ordered
according to GL for essential
service, propulsion 16)
X68
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the second and additional
motors ordered according to GL
for essential service, propulsion 16)
X69
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the first motor ordered
according to KR for essential service, propulsion 16)
X70
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the second and additional
motors ordered according to KR
for essential service, propulsion 16)
X71
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the first motor ordered
X72
according to LR for essential service,
16)
propulsion
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
Tests for the second and additional
motors ordered according to LR
for essential service, propulsion 16)
X73
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
E80
–
–
–
–
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
O.
R.
11
Special operating conditions
Motor for ship application, with
higher ambient temperature and/or
use of temperature class 180 (H)
utilized according to 130 (B) 16)
Tests in presence of representatives X99
of the customer (in addition to the
inspector of the classification
society)
For legends and footnotes, see Page 11/32.
Siemens D 81.8 · 04/2014
11/31
© Siemens AG 2014
Article No. supplements and special versions
Options
Explosion-proof motors
Standard version
Without additional charge
✓
With additional charge
•
This order code only determines the price of the version –
additional plain text is required.
O. R. On request
–
Not possible


11
1)
For DOL motors only.
2)
For VSD motors only.
3)
The following information is required in plain text when ordering: Rated
output, voltage (for DOL motors: line voltage, for VSD motors: rated motor
voltage), frequency and circuit.
4)
The following information is required in plain text when ordering: torque and
speed/frequency control range. Ordering is only possible in combination
with order codes M72, M73, M35 or M39.
5)
Not available in combination with order code K16 or K20.
6)
The standard temperature sensors (KTY) are omitted. If KTY and PTC
thermistors or Pt100 are required in combination, specify this in the order in
plain text. A combination of order codes A25 and A12; A25 and A61 or
A25 and A64 is available on request at an additional charge.
7)
Only in combination with the stainless steel auxiliary terminal box
(order code M51).
8)
Only available for standard cable entry. Special cable entry incl. cable
glands on request.
9)
Only available for admissible mounting positions, see Page 2/12.
10)
Order code K06 only in combination with order codes L00 and M58.
11)
Not available in combination with order code K30.
12)
Not available in combination with order code K50.
13)
Order code B60 or B61 must be ordered additionally.
14)
Only available for IM B3, IM V5, IM V6, IM V15 and IM V1 types of construction (14th position of Article No.: A, C, D, E, J). Not available in combination
with encoder mounting.
27) Specify
identical mounting position of pipe connection by selecting the
order code and Article No. (16th position of Article No.: 2, 3 or 4).
28) For
1.Q1-, 1.N1 and 1LP motors, only available for the main motor.
Not available for the separately driven fan motor.
29)
For 1.M1-, 1.Q1-, 1LL1- and 1LP1 motors, only available with the terminal
box position codes (15th position of Article No.) A to F and the separately
driven fan/heat exchanger position code (16th position of Article No.) 0 to 4
with the following exceptions: A2; B3 and C4. The position of the air outlets
or the separately driven fan results in constraints. For more information
about possible combinations, refer to the DT Configurator selection tool at:
www.siemens.com/dtconfigurator.
30)
For 1.N1 motors, constraints exist with regard to the terminal box position
(15th position of the Article No.) and the separately driven fan/heat
exchanger position (16th position of Article No.). For more information
about possible combinations, refer to the DT Configurator selection tool at:
www.siemens.com/dtconfigurator.
31)
Only available with 15th position of Article No.: A to F (terminal box
position).
32)
The rated speed must be specified in plain text in the order. If the rated
motor voltage corresponds to the catalog version, the required rated
output must be specified in addition. If the rated motor voltage does not
correspond to the catalog version, M1Y or M2Y must be ordered in
addition, and the required rated output must be specified there.
33)
Testing is performed with sinusoidal infeed. Only available for an electrical
rated frequency below 70 Hz.
34)
Testing is performed on the supply system. Only available for an electrical
rated frequency of 50 Hz.
35)
Only available for 1LM1 motors in 4-pole version, type of construction
IM B3, terminal box position code (15th position of Article No.) A, B, or C,
line voltage 400 V, 50 Hz and 460 V, 60 Hz. Only the following order codes
can be ordered in combination with the preferred motors:
A12, A61, A72, G50, H70, H73, K45, K46, K57, L00, L97, Y53.
36)
Industry solution for pump drive certified according to Lloyds Register
LR-T-3601 (Rev. 9 of August 2008 "Electric motors higher than 100 hp") and
LR-T-3601 (Rev. 8 of August 2008 "Vertical electric motors higher than
100 hp"). Only combinations of order codes E88 + E90 or
E89 + E90 can be ordered.
37)
Version of motors for Zone 2 without Ex nA II marking. For Ex nA II marking,
order code C27 is required in addition. Ex motors for converter-fed
operation are derated as compared to the non-Ex motors and temperature
class 155 (F) is no longer fully utilized. For utilization according to temperature class 130 (B), in accordance with VIK recommendation, order code
C10 is additionally required.
15)
Only available with 16th position of Article No.: 0, 1, 2 or 5
(separately driven fan/heat exchanger position).
16)
Not available for separately driven fan unit axial on NDE side
(16th position of Article No.: 1).
17)
Only for IM B3 and IM B35 type of construction
(14th position of Article No.: A, K).
18)
Only for IM B3 type of construction (14th position of Article No.: A).
19)
Only for IM B3, IM V5 and IM V6 types of construction
(14th position of Article No.: A, C, D).
20)
Only for rated speeds below 3000 rpm
(13th position of Article No.: 1, 2, 3, 4, 6, 7, 8).
21)
Not available for rated speed of 3600 rpm
(13th position of Article No.: 5).
22)
Only for IM B3, IM B5 with support foot and IM B35 types of construction
(14th position of Article No.: A, F, K).
38)
23)
Only available for IM V5, IM V6, IM V15 and IM V1 types of construction
(14th position of Article No.: C, D, G, J).
Order code L97 is included in the scope of supply in the case of 1.Q1,
1LP1 and 1.N1.
39)
Not available in combination with order code K20.
24)
Only available for IM V15, IM V1 and IM B35 types of construction
(14th position of Article No.: E, G, J, K).
Not available for rated speeds of 1800 rpm, 3000 rpm, 3600 rpm
(13th position of Article No.: 1, 5, 6).
40)
For motors with the 1.M1 and 1LL1 cooling methods, the maximum torque
for the second shaft extension is reduced by 50 %.
41)
25)
As a variation from the standard, only terminal boxes 1XB1 621 and 1XB1
631 are available.
Only available for IM B3 and IM B35 types of construction
(14th position of Article No.: A, K).
42)
26)
Only available for frame size 355 in combination with rated speed of
3000 rpm (13th position of Article No.: 1).
Ex nA II marking is on a separate plate.
*)
M = Torque
11/32
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Application-specific motors
12/2
12/2
12/3
12/4
12/4
12/5
12/5
12/5
12/5
12/5
12
12/7
12/7
12/7
12/7
12/7
12/7
12/8
Marine applications
Overview
• Classification societies
Benefits
Application
Technical specifications
• Housing design
• Water cooling
• Motor connection
• Specifications of the individual
classification societies with order
codes for ordering SIMOTICS FD
motors in marine design
• Temperature class and coolant
temperature
• Rating plate and acceptance
test certificate
• Degree of protection
• Winding and motor protection
• Paint finish
• Recommended special versions
More information
• Ordering notes
• Ordering examples
12/10
12/10
12/10
12/10
12/10
Chemical industry
Overview
• VIK version
Application
• Options for special environments
12/11
12/11
12/11
12/11
Water & waste water
Overview
Application
• Product range for the water & waste
water option packages
• Offer and ordering processes for
option package
• Technical content of option package
• Essential additional options
• Additional option recommended by
the manufacturer
12/6
12/7
12/11
12/12
12/12
12/12
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Application-specific motors
Marine applications
■ Overview
SIMOTICS FD (air-cooled and water-cooled) motors in marine
design have been developed for operation below deck onboard
ships. Motors intended for on deck operation or for offshore applications must be explicitly ordered using an additional order
code (Article No. with additional identification code -Z and order
code). The reason for this is that in these cases special measures are required. The thermal utilization of the motors is
matched to the generally higher ambient temperatures onboard
ship. If the application demands compliance with additional regulations, such as explosion protection, the appropriate motor series must be chosen.
The motors onboard ships are subdivided into three classes of
importance by the marine classification societies in collaboration with customers, depending on the application:
• "Essential Service for Propulsion" or also "Primary Essential
Service"
• "Essential Service" or also "Secondary Essential Service" or
"Important Service"
• "Non-Essential Service" or also "Non-Important Service"
As the assignment of a drive to one of the importance classes
has a direct impact on the scope of the marine options, this must
be known when ordering the motor.
The following services of the motor manufacturer are associated with the classes:
Class of importance
Essential Service for Propulsion
Essential Service
Non-Essential Service
General breakdown
Drives integrated into the propulsion system of the ship.
Safety-related drives whose failure
must not cause loss of maneuverability of the ship, nor place
onboard safety at risk.
Drives and systems that are outside
the responsibility of the classification societies.
Typical applications
Propeller drive, dynamic position- Lateral thrust units, anchor
ing drives, booster drives and shaft winches, oil and ballast pumps,
generators
fire-fighting pumps
Pumps for service water, winches,
dredging pumps, fans
Design
In accordance with regulations of
the classification society
In accordance with ambient conditions of the classification society
Acceptance test certificate
Acceptance test certificate 3.2 according to EN 10204
Individual acceptance by
classification society
Will be performed. Motor is assigned an individual certificate of the clas- Not required
sification society.
A declaration of conformity is
provided with the motor.
Ordering several identical motors
Differentiation between the first motor and additional ones must be real- No distinction
ized when ordering using an order code.
Rating plate data
Information about ambient conditions of the classification society
Stamp of the classification society
Stamp on the shaft 2) and motor housing
12
1)
Certificate is not stipulated by every classification society, but is always
issued according to the internal quality standards within the scope of a
routine test.
2)
Provided that it is specified that the classification society supervises
construction.
12/2
Siemens D 81.8 · 04/2014
Acceptance test certificate 3.2
according to EN 10204
Acceptance test certificate 3.1
according to EN 10204 1)
No stamp
© Siemens AG 2014
Application-specific motors
Marine applications
■ Overview (continued)
Classification societies
Society
Abbreviation
Location
American Bureau of Shipping
ABS
USA
Bureau Veritas
BV
France
China Classification Society
CCS
China
Det Norske Veritas
DNV
Norway
Germanischer Lloyd
GL
Germany
Korean Register
KR
Korea
Lloyds Register
LR
UK
Nippon Class
NK
Japan
Russian Maritime Register of
Shipping
RMRS
Russia
Other national classifications can be provided on request.
Regulations of the individual classification societies for motors:
Classification
society
Coolant temperature CT
Admissible temperature rise limit according to the
classification society
Water cooling
Temperature class
Air cooling
130 (B)
155 (F),
155 (F),
Prated ≥ 5000 kW Prated 5000 kW
Rated power
limit for individual acceptance
test
Construction
supervision
mandatory
°C
°C
K
K
K
kW
kW
ABS
32
50
70
95
90
≥ 100
–
BV
32
45
75
100
95
≥ 100
≥ 500
CCS
32
45
75
100
95
≥ 50
≥ 50
DNV
32
45
75
100
100
≥ 300
–
GL
32
45
75
100
100
≥ 50
All propulsion
KR
32
45
75
100
95
≥ 7.5
–
LR
32
45
70
95
90
≥ 100
≥ 100
NK
32
45
75
100
95
All power ratings –
RMRS
32
45
75
95
95
≥ 100
–
12
Siemens D 81.8 · 04/2014
12/3
© Siemens AG 2014
Application-specific motors
Marine applications
■ Benefits
• Increased corrosion protection using specially designed paint
finishes is available
• Open-circuit ventilated variant to IP23 is suitable for wellventilated and dry rooms
• Marine motors can be supplied for use in areas to be protected against explosion of Zone 2
• In depth know-how regarding customer requirements
• Worldwide service network with 24 hour service hotline for
motors and converters
The marine motors offer the user a number of advantages
and benefits:
• Cast-iron version is suitable for corrosive atmospheres
especially for high humidity levels and salty air
• Variable-speed drives reduce the energy consumption
verifiably
• Water cooling supports installation in small rooms and offers a
higher output yield than air cooling for the same frame size
■ Application
If marine motors are to be used on deck in especially corrosive
atmospheres or in offshore applications, then they must be additionally upgraded to meet these more stringent conditions.
Our marine motors are designed for use onboard ships (installed
below deck or on deck under a protective cover):
• Applications onboard ships as main and auxiliary drives
below deck, e.g.:
• Fans (air conditioning systems, refrigeration plants)
• Pumps (for fire-extinguishing or ballast water, fuels, oils)
• Compressors
• Bow thrusters and Azimuth drives
• Main propulsion drives
• Booster drives and shaft generators (power take-in/
power take-off mode)
• Ex motors for hazardous zones
Typical applications are:
• Coastal areas, e.g. oil rigs, drilling ships
• Winches
• Pumps
• Compressors
• Crane drives
Offshore versions must be specifically ordered, as they require
special measures.
M
Main drive
Motor
12
Typical applications
12/4
Siemens D 81.8 · 04/2014
Gen.
Diesel
Pumps,
fans
Bow thruster
Winches
M
G_D081_EN_00042
M
© Siemens AG 2014
Application-specific motors
Marine applications
■ Technical specifications
Housing design
SIMOTICS FD motors are designed with a rugged low-vibration
cast-iron housing.
Water cooling
For optimum utilization of the marine environment, two watercooling concepts are available for SIMOTICS FD motors:
• Conventional with air-to-water heat exchanger. In this case,
the warm air is routed from within the motor to a heat exchanger. After cooling here, it is drawn back into the machine
again.
• The cooling water flows through a meander tube that is
pressed into the stator core. The coolant is then extremely
close to the points where the heat is generated and can therefore cool extremely efficiently.
Both concepts support the use of fresh water and are provided
with measures that prevent the ingress of water into the motor
interior, e.g. use of double-pipe cooler.
Cooling with seawater is possible with an air-to-water heat
exchanger.
There are four categories of classification-specific options:
1 Design options define the marine-compatible technical design in accordance with the definitions of the classification
society in association with the international standards and
practices of our engineers.
2 Certification options define the scope of the test certificates
and cover all the expenses of the classification society and
Siemens.
3 Test options define the scope of the individual tests for final
acceptance of the motor in the presence of an inspector of the
respective classification society. A class-specific type test is
performed on the first motor, and a routine test is performed
on all subsequent motors.
4 Additional options for variations and special conditions –
specify the customer's request to participate in the tests at the
factory, or to define requirements that deviate from the standards of the classification society.
The options of the categories listed above are combined with
each other depending on the class of importance, classification
society and other conditions.
Motor connection
If motors are to be designed according to the specifications of
several classification societies, a special inquiry is necessary.
An undrilled entry plate is provided as standard, drilled entry
plates with or without cable glands are available on request.
Motors for Non-Essential Services
All marine motors generally have an external grounding terminal.
Specifications of the individual classification societies with
order codes for ordering SIMOTICS FD motors in marine
design
SIMOTICS FD in marine design
Cooling method
Type designation
Water-cooled motors with heat
exchanger for converter-fed
operation, IC86W cooling method
1LN
Water-cooled motors with waterjacket cooling for mains-fed and
converter-fed operation, IC71W
cooling method
1LH
Non-Essential Order codes for options in accordance with the classiService
fication society (Article No. with additional identification code -Z and order code)
ABS
Air-cooled motors for converter-fed 1LM
operation (self-ventilated), IC411
cooling method
Air-cooled motors with mounted
1LQ
separately driven fan for converterfed operation, IC416 cooling
method
Open-circuit ventilated motors for 1LL, 1LP
converter-fed operation, IC01 and
IC06 cooling method
SIMOTICS FD motors for marine applications must be ordered
with classification-specific options. This ensures that both the
mechanical design of the motor and the tests are performed
exactly in accordance with the instructions provided by the
respective classification society.
1)
The technical design is in accordance with the ambient operating conditions specified by the classification society. One of the
marine design options must be ordered by specifying the respective order code X00, X01, X12 1), X03, X04, X05 or X06 (depending on the classification society). Acceptance inspections
are not required. There is no distinction between ordering an individual motor or several motors.
Technical
version
X00
BV
CCS
DNV
GL
KR
LR
X01
X12 1)
X03
X04
X05
X06
Motors for Essential Services
The technical design is in accordance with regulations of the
classification society: Options with the order codes X10 to X16.
An acceptance test certificate 3.2 according to EN 10204 and a
product certificate of the classification society is provided with
each motor. The options with order codes J70 to J82 (first motor), or J71 to J83 (additional motors) define the costs for certification of the motor.
Depending on the classification society, the test steps are controlled by the options with order codes X30 to X42 for the first
motor (even numbers) and X31 to X43 for the additional motors
(uneven numbers).
Non-Essential Service is handled by CCS in the same manner as Essential
Service.
Siemens D 81.8 · 04/2014
12/5
12
© Siemens AG 2014
Application-specific motors
Marine applications
■ Technical specifications (continued)
Order codes for options in accordance with the classification society (Article No. with additional identification code -Z and order code)
Essential
Service
ABS
BV
CCS
DNV
GL
KR
LR
X10
X11
X12
X13
X14
X15
X16
• First motor
J70
J72
J74
J76
J78
J80
J82
• Additional
motors
J71
J73
J75
J77
J79
J81
J83
Technical version
Certification
Acceptance tests with classification
• First motor
X30
X32
X34
X36
X38
X40
X42
• Additional
motors
X31
X33
X35
X37
X39
X41
X43
Motors for Essential Services for Propulsion
The technical design is in accordance with regulations of the
classification society: Options with the order codes X20 to X26.
An acceptance test certificate 3.2 according to EN 10204 and a
product certificate of the classification society is provided with
each motor. The options with order codes N40 to N52 (first motor), or N41 to N53 (additional motors) define the costs for certification of the motor.
Depending on the classification society, the test steps are controlled by the options with order codes X60 to X72 for the first
motor (even numbers) and X61 to X73 for the additional motors
(uneven numbers).
Order codes for options in accordance with the classification society (Article No. with additional identification code -Z and order code)
BV
CCS
DNV
GL
KR
LR
X20
X21
X22
X23
X24
X25
X26
• First motor
N40
N42
N44
N46
N48
N50
N52
• Additional
motors
N41
N43
N45
N47
N49
N51
N53
Certification
Acceptance tests with classification
• First motor
X60
X62
X64
X66
X68
X70
X72
• Additional
motors
X61
X63
X65
X67
X69
X71
X73
Tests in the presence of representatives of the customer
(in addition to the inspector of the classification society)
X99
12/6
All other tests can be ordered separately via the standard options for industrial motors. They will be performed in addition to
the specified measurements. You will find the complete range of
options for tests in section 10 of the catalog "Article No. supplements and special versions" under "Options".
Notice:
Scope of design options X00 to X26
The design options include all classification-specific technical
measures. These options are bundles of additional modifications
and accessories which make a motor marine-compatible as well
as classification-compliant and application-compatible.
Temperature class and coolant temperature
Standard motors and explosion-proof motors
Marine motors are normally designed for a coolant temperature
of CT 45 °C or a cooling water temperature of 32 °C for utilization
according to temperature class 155 (F). Motors according to the
ABS classification that specify CT 50 °C are an exception. For
reduction factors for cooling air and water temperature, see
Page 3/2.
More detailed information is available on request.
Technical version
12
According to regulations, the acceptance tests are performed in
the presence of an inspector of the classification society. If the
customer or his representative is required to be present during
the tests, order code X99 must be specified. In this case, the
ordering party will be informed as to the dates in the form of an
invitation.
If, for example, a motor according to the ABS classification is
required for an ambient temperature of 45 °C, in addition to the
order codes for marine options, order code D11 must also be
specified.
X99
ABS
Order code X99:
All options that can be ordered with order codes must also be ordered using these order codes.
Tests in the presence of representatives of the customer
(in addition to the inspector of the classification society)
Essential
Service for
Propulsion
Additional options
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Application-specific motors
Marine applications
■ Technical specifications (continued)
Rating plate and acceptance test certificate
Paint finish
The metal rating plate indicates the relevant classification society and the associated coolant temperature. The housings of all
certified motors are stamped with the certificate number and
identifier of the society or testing agency, in accordance with
regulations. These stamps are in the vicinity of the rating plate.
The paint thickness is greater than standard and is included in
the option for the technical design. This is suitable for indoor and
outdoor use under a roof or cover.
The results of the acceptance test are supplied with the motor
certificate and the motor.
A paint finish according to EN ISO 12944-5 C5-M is used for
unprotected installation on deck, especially aggressive atmospheres or offshore applications. This is part of order code E81,
which upgrades a standard marine motor for these special ambient conditions.
Special paint colors and increased layer thicknesses are available on request.
3~ Mot. 1LN1 222-3AB73-2AC5-Z
m: 2.07 t
IP 55
SIMOTICS FD
IM B3 Ta: -20…+45°C Th.Cl.:
NoN- xx9900006090001/2013
180(H) Util.:155(F)
nmax: 3000 1/min IEC/EN 60034-1
U [V]
I [A]
660 D
510
P [kW] cosφ n [1/min] f [Hz]
505
0.90
1500
50.6
Eff.
95.9%
Mot. design: FOR INVERTER DUTY ONLY
Line supply: 690V / 50Hz
KÜHLW./COOL.WATER 115 L/MIN, 25°C
Made in Germany D-90441 Nürnberg
DEW0400
MAX. WASSERDRUCK / WATER PRESSURE 6 BAR
G_D081_XX_00459
MARINE EQUIPMENT / CLASSIFICATION SOCIETY: DNV
Recommended special versions
• Rust-resistant screws (externally) – Order code M27
• Shock Pulse Measurement (SPM) nipple for monitoring the
bearing vibrations for essential and non-essential motors –
Order code G50
• Mounting of 2 Pt100 screw-in resistance thermometers
in basic circuit for rolling-contact bearings for essential and
non-essential motors – Order code A72
• IP56 degree of protection (non-heavy-sea) for protection
against water jets from any direction – Order code K52
• Upgrading a marine motor for unprotected installation on
deck, use in especially aggressive atmospheres or offshore
applications – on request
Degree of protection
The degrees of protection as specified in the catalog apply.
For IP56 (non-heavy sea, order code K52) the formation of ice
must be avoided.
Winding and motor protection
To monitor the winding and, if specified by the classification society, to monitor the bearings, the motors are equipped with PTC
thermistors, temperature sensors or resistance thermometers.
All water-cooled motors are equipped with leak sensors as protection against leaks in the cooling circuit. The complete scope
of standard accessories depends on the society and importance
class.
■ More information
12
Ordering notes
The fees of the classification societies for necessary authorizations, individual acceptance inspections and certificates are
included in the order code.
Siemens D 81.8 · 04/2014
12/7
© Siemens AG 2014
Application-specific motors
Marine applications
■ More information (continued)
For selection and ordering data, see sections 4 to 10 of the catalog.
Ordering examples
Selection criteria
Requirement
Structure of the Article No.
1st ordering example: 5 motors for Non-Essential Service according to GL (Germanischer Lloyd), Germany
Motor type
SIMOTICS FD self-ventilated, IC411 cooling method, IP55 degree of
protection
1LM1■■■– ■■■■■– ■■■■
Motor series
Low-noise standard version
1LM1 2 ■■– ■■■■■– ■■■■
System description
Operation on SINAMICS converter with unregulated infeed
1LM1 2 2 ■– ■■■■■– ■■■■
Efficiency
Premium efficiency
1LM1 2 2 3 – ■■■■■– ■■■■
Frame size
315
1LM1 2 2 3 – 3 A■■■– ■■■■
No. of poles
4-pole
1LM1 2 2 3 – 3 AB■■– ■■■■
Laminated core length
average
1LM1 2 2 3 – 3 AB5 ■– ■■■■
Line voltage and frequency
690 V, 50 Hz – VSD
1LM1 2 2 3 – 3 AB5 3 – ■■■■
Rated speed
1500 rpm
1LM1 2 2 3 – 3 AB5 3 – 2 ■■■
Type of construction
IM B3
1LM1 2 2 3 – 3 AB5 3 – 2 A■■
Terminal box position
Standard version (terminal box on DE top)
1LM1 2 2 3 – 3 AB5 3 – 2 AA■
Separately driven fan position
No separately driven fan/heat exchanger
1LM1 2 2 3 – 3 AB5 3 – 2 AA0
Special versions
Technical version according to GL, CT (air) = 45 °C, temperature class
1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z
155 (F) used acc. to 155 (F) incl.: Insulated bearing at NDE, coated inter- X04
nal surfaces and special external coating with 240 µm, 3 PTC thermistors
for alarm and tripping in the winding
Article No. for all 5 motors
1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z
X04
2nd ordering example: 5 motors for Essential Service according to BV (Bureau Veritas), France
Motor type
Motor of example 1
1LM1 2 2 3 – 3 AB5 3 – 2 AA0
Special versions
Technical version according to BV, CT (air) = 45 °C, temperature class
1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z
155 (F) used acc. to 155 (F) incl.: Insulated bearing at NDE, coated inter- X11
nal surfaces and special external coating with 240 µm, 3 PTC thermistors
for alarm and tripping in the winding
1st motor
4 additional motors
12
12/8
Certification required for first ordered motor acc. to BV
1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z
X11+J72
Tests required for first ordered motor acc. to BV
1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z
X11+J72+X32
Article No. for 1st motor
1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z
X11+J72+X32
Technical version according to BV, CT (air) = 45 °C, temperature class
1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z
155 (F) used acc. to 155 (F) incl.: Insulated bearing at NDE, coated inter- X11
nal surfaces and special external coating with 240 µm, 3 PTC thermistors
for alarm and tripping in the winding
Certification required for additional ordered motors acc. to BV
1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z
X11+J73
Tests required for additional ordered motors acc. to BV
1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z
X11+J73+X33
Article No. for the additional 4 motors
1LM1 2 2 3 – 3 AB5 3 – 2 AA0 -Z
X11+J73+X33
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Application-specific motors
Marine applications
■ More information (continued)
Ordering examples (continued)
Selection criteria
Requirement
Structure of the Article No.
3rd ordering example: 2 motors for Essential Service for Propulsion according to DNV (Det Norske Veritas), Norway
Motor type
SIMOTICS FD water-cooled, IC71W cooling method, IP55 degree of
protection
1LH1 ■■■– ■■■■■– ■■■■
Motor series
Low-noise standard version
1LH1 2 ■■– ■■■■■– ■■■■
System description
Operation on SINAMICS converter with regulated infeed
1LH1 2 1 ■– ■■■■■– ■■■■
Efficiency
Premium efficiency
1LH1 2 1 3 – ■■■■■– ■■■■
Frame size
315
1LH1 2 1 3 – 3 A■■■– ■■■■
No. of poles
4-pole
1LH1 2 1 3 – 3 AB■■– ■■■■
Laminated core length
average
1LH1 2 1 3 – 3 AB5 ■– ■■■■
Line voltage and frequency
690 V, 50 Hz – VSD
1LH1 2 1 3 – 3 AB5 3 – ■■■■
Rated speed
1500 rpm
1LH1 2 1 3 – 3 AB5 3 – 2 ■■■
Type of construction
IM B3
1LH1 2 1 3 – 3 AB5 3 – 2 A■■
Terminal box position
Terminal box on DE right-hand
1LH1 2 1 3 – 3 AB5 3 – 2 AB■
Separately driven fan position
No separately driven fan/heat exchanger
1LH1 2 1 3 – 3 AB5 3 – 2 AB0
Special versions
1st motor
This option is not mandatory.
Additional motor
Technical version according to DNV, CT (water) = 32 °C, temperature
1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z
class 155 (F) used acc. to 155 (F) incl.: Insulated bearing at NDE,
X13
painted internal surfaces and external special coating of 240 µm, 6 x
Pt100 in stator winding, Pt100 for monitoring the bearing temperature,
cables routed externally in stainless steel hoses, heating, leakage sensor,
SPM nipple
Certification required for first ordered motor acc. to DNV
1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z
X13+J76
Tests required for first ordered motor acc. to DNV
1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z
X13+J76+X36
Tests in the presence of representatives of the customer (in addition to
the inspector of the classification society)
1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z
X13+J76+X36+X99
Article No. for 1st motor
1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z
X13+J76+X36+X99
Technical version according to DNV, CT (water) = 32 °C, temperature
1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z
class 155 (F) used acc. to 155 (F) incl.: Insulated bearing at NDE,
X13
painted internal surfaces and external special coating of 240 µm, 6 x
Pt100 in stator winding, Pt100 for monitoring the bearing temperature,
cables routed externally in stainless steel hoses, heating, leakage sensor,
SPM nipple
Certification required for additional ordered motors acc. to DNV
1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z
X13+J77
Tests required for additional ordered motors acc. to DNV
1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z
X13+J77+X37
Article No. for the second motor
1LH1 2 1 3 – 3 AB5 3 – 2 AB0 -Z
X13+J77+X37
Siemens D 81.8 · 04/2014
12/9
12
© Siemens AG 2014
Application-specific motors
Chemical industry
■ Overview
In the chemical industry, motors are subjected to external influences in the extreme. Operation in hazardous areas and aggressive atmospheres, in particular, result in a need to protect the
motor using special measures.
To ensure safe and reliable operation, it is important to verify the
following:
• Explosion protection
• Degree of protection
• Ambient conditions
To meet the requirements of the chemical industry, SIMOTICS FD
motors are available in a large number of industry-specific versions.
VIK version
The recommendations of the VIK ("Verband der Industriellen
Energie- und Kraftwirtschaft e. V.", the Association of the
Industrial Energy and Power Industry) describe the requirements for three-phase induction motors as often required by
the chemical industry:
• VIK standard version:
1L.1 + order code K30 1) – "VIK" identification on rating plate.
• VIK Ex n version:
1M.1 + order code K30 1) – "VIK" identification on rating plate;
"Ex nA IIC T3 Gc" on an extra rating plate in accordance with
Directive 94/9/EC (ATEX)
Both motor versions include the technology for Zone 2 in "Non
sparking" type of protection. In accordance with the technical requirements of VIK, motors can be supplied in frame sizes 315
and 355.
■ Application
Options for special environments
Further options for the chemical industry
In the chemical industry, a wide range of different environmental
conditions occur. Through a series of options, the motors can be
adapted to the conditions at the installation site.
Additional options are listed below that are typically required for
applications in the chemical industry.
Order code
Characteristics
Order code
Characteristics
M72
K26
Outdoor use: Exposure to the weather admissible,
minimal chemical pollution (SO2), direct solar radiation;
Special finish in RAL 7030 stone gray (corrosivity
category C2)
Design for Zone 2 for mains-fed operation Ex nA II T3
according to IEC/EN 60079-15
M73
Design for Zone 2 for converter-fed operation, with
derating Ex nA II T3 according to IEC/EN 60079-15
M35
Design for Zone 22 for non-conductive dust (IP55) for
mains-fed operation
M39
Design for Zone 22 for non-conductive dust (IP55) for
converter-fed operation, derating
E83
Outdoor use: Municipal and industrial atmospheres,
moderate chemical pollution (SO2), minimal salinity,
direct exposure to weather; special finish (corrosivity
category C3)
K56
IP56 degree of protection (non-heavy-sea)
E82
Outdoor use: Industrial areas and coastal areas with
moderate salinity, direct exposure to weather, frequent
condensation, special finish (corrosivity category C4)
K50
IP65 degree of protection
M27
Rust-resistant screws
E81
Outdoor use: Coastal and offshore areas with a high
level of pollution and almost continuous condensation
or industrial areas with high levels of humidity or corrosive atmospheres; special finish (corrosivity category C5-M/C5-I)
K35
Metal external fan
M06
Special case: Sulfurous atmosphere; special finish
(corrosivity category C3)
12
1)
For K30, the metal external fan must be ordered with order code K35.
12/10
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Application-specific motors
Water & waste water
■ Overview
Siemens motors and converters ensure optimized pumping processes and maximum availability for minimum operating costs.
The full benefit is realized when Siemens drive components
interact as a system, because the motors and converters are
perfectly tuned to each other as early as the development stage
and then subjected to tests for ruggedness under real conditions. The drive systems are therefore characterized by a high
level of availability and maximum efficiency.
For this reason, an option package has been specially designed
for the low-voltage motors of the SIMOTICS FD series in combination with a SINAMICS frequency converter for pump drives.
This simplifies offer and order processing, in particular, for pump
drives used in desalination plants and similar applications with
certification in accordance with the Lloyds Register.
Furthermore, using variable-speed drive technology, volumetric
flow can be controlled much more accurately and faster than
using mechanical control components for adaptation to actual
demand. The advantages are, for example, noticeably higher
safety and quality for drinking water from desalination plants.
Variable-speed operation also opens up an enormous potential
for savings which frequently results in a SINAMICS frequency
converter paying for itself after just a few months of operation.
■ Application
Product range for the water & waste water option packages
Motor version
Cooling method
Motor type
Frame size
Operating mode
Air-cooled, enclosed version with
self-ventilation
IC 411
1LM1
315 ... 450
VSD
Air-cooled, enclosed version with
forced-air cooling
IC 416
1LQ1
315 ... 450
VSD
Water-cooled version with
water-jacket cooling
IC 71W
1LH1
315 ... 450
VSD, DOL
Water-cooled version with
heat exchanger
IC 86W
1LN1
315 ... 450
VSD
Air-cooled, open version with
self-ventilation
IC 01
1LL1
315 ... 450
VSD
Air-cooled, open version with
forced-air cooling
IC 06
1LP1
315 ... 450
VSD
The water option package has not been approved for use in hazardous areas.
Offer and ordering processes for option package
The water option package has the following order code:
Additional iden- Description
tification code
–Z with order
code
E90
Pump drive for seawater desalination plants certified
according to Lloyds Register
Commissioning of the classification society must also be specified. It is possible to specify whether Siemens or the contractual
partner of Siemens should commission the classification society.
The relevant order code must be specified in the order.
12
Additional iden- Description
tification code
–Z with order
code
E88
Commissioning of the classification society
by Siemens
E89
Commissioning of the classification society
by third party
Siemens D 81.8 · 04/2014
12/11
© Siemens AG 2014
Application-specific motors
Water & waste water
■ Application (continued)
Technical content of the option package
Order code E90 comprises the following technical content:
"Balancing report" document
The following acceptance tests will be performed by Lloyds Register in the Siemens factory at Nuremberg:
Inspection
Remarks
Material used
Certificate of the shaft according to EN 10204-3.1
Certificate for laminated core and copper according to EN 10204-2.1
Weld seams
Weld seams according to EN 287-1
Testing Welders – Welding – Part 1: steels,
German version EN 287-1:2004 + A2:2006
Housing drawings
Site supervision / inspection
Air gap measurements
No measurement, the theoretically determined value based on stator bore and rotor external
diameter can be provided on request for an additional charge
Rotor design
Site supervision / inspection
Winding version
Site supervision / inspection
Winding insulation
Site supervision / inspection
Design, balancing
Site supervision / inspection
Motor dimensions, feet dimensions
Site supervision / inspection
Axial rotor play
No measurement, guaranteed value is stated in the documentation
First critical speed
No measurement, depending on the motor type the machines are subcritical or supercritical
Paints and varnishes
Certificate for layer thickness measurement
Essential additional options
The following options must be ordered separately when the "Water" option package is ordered:
Additional iden- Description
tification code
–Z with order
code
F29
Noise measurement (in no-load operation), no noise analysis, with acceptance
F53
Measurement of locked-rotor torque and current, with acceptance
F59
Vibration analysis with acceptance test according to IEC 60034-14
F01
Routine test with customer acceptance test
or
F83
Type test with heat run for horizontal motors (IMB3), with acceptance
or
F93
12
Type test with heat run for vertical motors (IMV1), with acceptance
Additional option recommended by the manufacturer
Based on many years of experience in the field of motors, it is recommended that a special paint finish is applied to them.
Additional iden- Description
tification code
–Z with order
code
K26
12/12
Special finish
Siemens D 81.8 · 04/2014
13
© Siemens AG 2014
Appendix
13/2
Partners at Industry Automation and
Drive Technologies
13/3
Online Services
Information and Ordering in the
Internet and on DVD
Siemens Industry Automation and
Drive Technologies in the WWW
Product Selection using the
Interactive Catalog CA 01 of Industry
Easy Shopping with the Industry Mall
Information and Download Center
Social Media, Mobile Media
Downloading Catalogs
Social Media
Mobile Media
13/3
13/3
13/3
13/4
13/4
13/4
13/5
13/5
13/8
13/9
13/9
13/9
Industry Services
Your machines and plant can do more
– with Industry Services.
Industry Services for the entire life cycle
Online Support
Technical Support
Spare Parts
Repair Services
Field Services
Training
Technical Consulting & Engineering
Support
Energy & Environmental Services
Modernization & Optimization Services
Plant Maintenance & Condition Monitoring
Service Contracts
13/10
13/10
13/13
Indexes
Subject index
Index of article numbers
13/15
Metal surcharges
13/15
13/16
13/16
13/16
13/16
13/16
13/17
Explanation of the raw material/
metal surcharges
Surcharge calculation
Structure of the metal factor
Weight method
Percentage method
Metal factor examples
Explanation of the raw material/metal
surcharges for dysprosium and neodym
(rare earths)
Surcharge calculation
Three-month average price
Structure of the metal factor
Weight method
Metal factor examples
Values of the metal factor
13/18
13/18
13/18
13/18
Conditions of sale and delivery
General Provisions
Prices
Additional Terms and Conditions
13/18
Export regulations
13/6
13/6
13/6
13/7
13/7
13/7
13/8
13/8
13/15
13/15
13/15
13/15
13/15
13/16
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Appendix
Partners at Industry Automation and Drive Technologies
At Siemens Industry Automation and Drive Technologies, more
than 85 000 people are resolutely pursuing the same goal: longterm improvement of your competitive ability. We are committed
to this goal. Thanks to our commitment, we continue to set new
standards in automation and drive technology. In all industries –
worldwide.
At your service locally, around the globe for consulting, sales,
training, service, support, spare parts ... on the entire Industry
Automation and Drive Technologies range.
Your personal contact can be found in our Contacts Database at:
www.siemens.com/automation/partner
You start by selecting a
• Product group,
• Country,
• City,
• Service.
13
13/2
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Appendix
Online Services
Information and Ordering
in the Internet and on DVD
■ Siemens Industry Automation and Drive Technologies in the WWW
A detailed knowledge of the range of products and services
available is essential when planning and configuring automation
systems. It goes without saying that this information must always
be fully up-to-date.
Siemens Industry Automation and Drive Technologies has
therefore built up a comprehensive range of information in the
World Wide Web, which offers quick and easy access to all data
required.
Under the address
www.siemens.com/industry
you will find everything you need to know about products,
systems and services.
■ Product Selection Using the Interactive Catalog CA 01 of Industry
Detailed information together with convenient interactive
functions:
The interactive catalog CA 01 covers more than 80 000 products
and thus provides a full summary of the Siemens Industry
Automation and Drive Technologies product base.
Here you will find everything that you need to solve tasks in the
fields of automation, switchgear, installation and drives.
All information is linked into a user interface which is easy to
work with and intuitive.
After selecting the product of your choice you can order at the
press of a button, by fax or by online link.
Information on the interactive catalog CA 01 can be found in the
Internet under
www.siemens.com/automation/ca01
or on DVD.
■ Easy Shopping with the Industry Mall
The Industry Mall is the electronic ordering platform of
Siemens AG on the Internet. Here you have online access
to a huge range of products presented in an informative and
attractive way.
Data transfer via EDIFACT allows the whole procedure from
selection through ordering to tracking and tracing of the order to
be carried out. Availability checks, customer-specific discounts
and preparation of quotes are also possible.
Numerous additional functions are available to support you.
For example, powerful search functions make it easy to select
the required products. Configurators enable you to configure
complex product and system components quickly and easily.
CAx data types are also provided here.
Please visit the Industry Mall on the Internet under:
www.siemens.com/industrymall
Siemens D 81.8 · 04/2014
13/3
13
© Siemens AG 2014
Appendix
Online Services
Information and Download Center
Social Media, Mobile Media
■ Downloading Catalogs
In addition to numerous other useful documents, you can also
find the catalogs listed on the back inside cover of this catalog
in the Information and Download Center. Without having to
register, you can download these catalogs in PDF format or
increasingly as digital page-turning e-books.
The filter dialog box above the first catalog displayed makes it
possible to carry out targeted searches. If you enter “MD 3” for
example, you will find both the MD 30.1 and MD 31.1 catalogs.
If you enter “ST 70” both the ST 70 catalog and the associated
news or add-ons are displayed.
Visit us on the web at:
www.siemens.com/industry/infocenter
■ Social Media
Connect with Siemens through social media: visit our social
networking sites for a wealth of useful information, demos on
products and services, the opportunity to provide feedback,
to exchange information and ideas with customers and other
Siemens employees, and much, much more. Stay in the know
and follow us on the ever-expanding global network of social
media.
Connect with Siemens Industry at our central access point:
www.siemens.com/industry/socialmedia
Or via our product pages at:
www.siemens.com/automation
or
www.siemens.com/drives
To find out more about Siemens' current social media activities
visit us at:
www.siemens.com/socialmedia
■ Mobile Media
Discover the world of Siemens.
We are also constantly expanding our offering of cross-platform
apps for smartphones and tablets. You will find the current
Siemens apps at the app store (iOS) or at Google Play (Android).
13
The Siemens app, for example, tells you all about the history,
latest developments and future plans of the company – with
informative pictures, fascinating reports and the most recent
press releases.
13/4
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Appendix
Industry Services
Your machines and plant can do more
– with Industry Services.
Whether it is production or process industry – in view of rising
cost pressure, growing energy costs, and increasingly stringent
environmental regulations, services for industry are a crucial
competitive factor in manufacturing as well as in process industries.
All over the world Siemens supports its customers with product,
system, and application-related services throughout the entire
life cycle of a plant. Right from the earliest stages of planning,
engineering, and building, all the way to operation and modernization. These services enable customers to benefit from the
Siemens experts’ unique technological and product knowledge
and industry expertise.
Thus downtimes are reduced and the utilization of resources is
optimized. The bottom line: increased plant productivity, flexibility, and efficiency, plus reduced overall costs.
Discover all advantages of our service portfolio:
www.siemens.com/industry-services
7HFKQLFDO&RQVXOWLQJ
(QJLQHHULQJ6XSSRUW
(QHUJ\
(QYLURQPHQWDO6HUYLFHV
7HFKQLFDO&RQVXOWLQJ
(QJLQHHULQJ6XSSRUW
(QHUJ\
(QYLURQPHQWDO6HUYLFHV
0RGHUQL]DWLRQ
2SWLPL]DWLRQ6HUYLFHV
Modernization
Modernization
Planning
Planning
Online Support
Technical Support
Spare Parts
Repair Services
Field Services
Training
Operation
Operation
7HFKQLFDO&RQVXOWLQJ
(QJLQHHULQJ6XSSRUW
Engineer
Engineer
&
& Build
Build
(QHUJ\
(QYLURQPHQWDO6HUYLFHV
3ODQW0DLQWHQDQFH
&RQGLWLRQ0RQLWRULQJ
6HUYLFH&RQWUDFWV
(QHUJ\(QYLURQPHQWDO6HUYLFHV
0RGHUQL]DWLRQ2SWLPL]DWLRQ6HUYLFHV
G_DA65_EN_00270
Siemens supports its clients with technology based Services across a plants entire life cycle.
Siemens D 81.8 · 04/2014
13/5
13
© Siemens AG 2014
Appendix
Industry Services
Industry Services
for the entire life cycle
Online Support
Online support is a comprehensive information system for all
questions relating to products, systems, and solutions that
Siemens has developed for industry over time. With more than
300,000 documents, examples and tools, it offers users of automation and drive technology a way to quickly find up-to-date information. The 24-hour service enables direct, central access to
detailed product information as well as numerous solution examples for programming, configuration and application.
The content, in six languages, is increasingly multimediabased
– and now also available as a mobile app. Online support’s
“Technical Forum” offers users the opportunity to share information with each other. The “Support Request” option can be used
to contact Siemens’ technical support experts. The latest content, software updates, and news via newsletters and Twitter ensure that industry users are always up to date.
www.siemens.com/industry/onlinesupport
Online Support App
Using the Online Support app, you can access over 300,000
documents covering all Siemens industrial products – anywhere,
any time. Regardless of whether you need help implementing
your project, fault-finding, expanding your system or are planning a new machine.
The search function retrieves product information and articles
and supports you with a personalized suggestion list. You can
find your favorite pages – articles you need frequently – under
“mySupport”. You also receive selected news on new functions,
important articles or events in the News section.
You have access to FAQs, manuals, certificates, characteristics
curves, application examples, product notices (e.g. announcements of new products) and information on successor products
in the event that a product is discontinued.
Just scan the product code printed on the product directly using
the camera of your mobile device to immediately see all technical information available on this product at a glance. The graphical CAx information (3D model, circuit diagrams or EPLAN
macros) is also displayed. You can forward this information to
your workplace using the e-mail function.
Scan the QR code
for information on
our Online Support
app.
The app is available free of charge from the Apple App Store
(iOS) or from Google Play (Android).
www.siemens.com/industry/onlinesupportapp
Technical Support
13
The ability to quickly analyze system and error messages and
take appropriate action are key factors in ensuring that plants
run safely and efficiently. Questions can arise at any time and in
any industry, whether it’s an individual product or a complete
automation solution. Siemens technical support offers individual
technical assistance in matters related to functionality, how to
operate, applications, and fault clearance in industrial products
and systems – at any time and globally, over the phone, by email, or via remote access. Experienced experts from Siemens
answer incoming questions promptly. Depending on the requirements, they first consult specialists in the areas of development,
on-site services, and sales. Technical support is also available
for discontinued products that are no longer available. Using the
support request number, any inquiry can be clearly identified
and systematically tracked.
http://support.automation.siemens.com/WW/view/en/16605032
13/6
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Appendix
Industry Services
Industry Services
for the entire life cycle
Spare Parts
Drive and automation systems must be available at all times.
Even a single missing spare part can bring the entire plant to a
standstill – and result in substantial financial losses for the operator. The spare parts services from Siemens protects against
such losses – with the aid of quickly available, original spare
parts that ensure smooth interaction with all other system components. Spare parts are kept on hand for up to ten years; defective parts can be returned. For many products and solutions,
individual spare parts packages ensure a preventive stock of
spare parts on-site. The spare parts services is available around
the world and around the clock. Optimum supply chain logistics
ensure that replacement components reach their destination as
quickly as possible. Siemens’ logistics experts take care of planning and management as well as procurement, transportation,
customs handling, warehousing, and complete order management for spare parts.
http://support.automation.siemens.com/WW/view/en/43502238
Repair Services
Reliable electrical and electronic equipment is crucial for operating continuous processes. That is why it is essential that motors and converters always undergo highly specialized repair
and maintenance. Siemens offers complete customer and repair
services – on site and in repair centers – as well as technical
emergency services worldwide. The repair services include all
measures necessary to quickly restore the functionality of defective units. In addition, services such as spare parts logistics,
spare parts storage and rapid manufacturing are available to
plant operators in all verticals. With a global network of certified
repair shops operated by Siemens as well as third parties,
Siemens handles the maintenance and overhaul of motors,
converters, and other devices as an authorized service partner.
http://support.automation.siemens.com/WW/view/en/43512848
Field Services
It’s a top priority in all industries: the availability of plants and
equipment. Siemens offers specialized maintenance services
such as inspection and upkeep as well as rapid fault clearance
in industrial plants – worldwide, continuously, and even with
emergency services as needed. The services include startup as
well as maintenance and fault clearance during operation. The
startup service includes checking the installation, function tests,
parameterization, integration tests for machines and plants, trial
operation, final acceptance, and employee training. All services,
including remote maintenance of drives, are also available as
elements of customized service contracts.
13
http://support.automation.siemens.com/WW/view/en/66012486
Siemens D 81.8 · 04/2014
13/7
© Siemens AG 2014
Appendix
Industry Services
Industry Services
for the entire life cycle
Training
Increasingly, up-to-date knowledge is becoming a determining
factor in success. One of the key resources of any company is
well-trained staff that can make the right decision at the right
moment and take full advantage of the potential. With SITRAIN –
Training for Industry, Siemens offers comprehensive advanced
training programs. The technical training courses convey expertise and practical knowledge directly from the manufacturer.
SITRAIN covers Siemens’ entire product and system portfolio in
the field of automation and drives. Together with the customer,
Siemens determines the company’s individual training needs
and then develops an advanced training program tailored to the
desired requirements. Additional services guarantee that the
knowledge of all Siemens partners and their employees is
always up-to-date.
http://support.automation.siemens.com/WW/view/en/43514324
Technical Consulting & Engineering Support
The efficiency of plants and processes leads to sustainable
economic success. Individual services from Siemens help save
substantial time and money while also guaranteeing maximum
safety. Technical consulting covers the selection of products and
systems for efficient industrial plants. The services include
planning, consulting, and conceptual design as well as product
training, application support, and configuration verification – in
all phases of a plant’s lifecycle and in all questions related to
product safety. Engineering support offers competent assistance throughout the entire project, from developing a precise
structure for startup to product-specific preparation for implementation as well as support services in areas such as prototype
development, testing and acceptance.
Energy & Environmental Services
13
Efficient energy use and resource conservation – these top
sustainability concerns pay off – both for the environment and for
companies. Siemens offers integrated solutions that unlock all
technical and organizational potential for successful environmental management. Customized consulting services are aimed
at sustainably lowering the cost of energy and environmental
protection and thus increasing plant efficiency and availability.
The experts provide support in the conceptual design and implementation of systematic solutions in energy and environmental management, enabling maximum energy efficiency and
optimized water consumption throughout the entire company.
Improved data transparency makes it possible to identify
savings potential, reduce emissions, optimize production
processes, and thereby noticeably cut costs.
http://support.automation.siemens.com/WW/view/en/42350774
13/8
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Appendix
Industry Services
Industry Services
for the entire life cycle
Modernization & Optimization Services
High machine availability, expanded functionality and selective
energy savings – in all industries, these are decisive factors for
increasing productivity and lowering costs. Whether a company
wants to modernize individual machines, optimize drive systems, or upgrade entire plants, Siemens’ experts support the
projects from planning to commissioning.
Expert consulting and project management with solution responsibility lead to security and make it possible to specifically identify savings potential in production. This secures investments
over the long term and increases economic efficiency in operation.
http://support.automation.siemens.com/WW/view/en/66005532
Plant Maintenance & Condition Monitoring
Modern industrial plants are complex and highly automated.
They must operate efficiently in order to ensure the company’s
competitive strength. In addition, the steadily increasing networking of machines and plants require consistent security concepts. Maintenance and status monitoring as well as the implementation of integrated security concepts by Siemens’ experts
support optimum plant use and avoid downtime. The services
include maintenance management as well as consulting on
maintenance concepts, including the complete handling and
execution of the necessary measures. Complete solutions also
cover remote services, including analysis, remote diagnosis,
and remote monitoring. These are based on the Siemens
Remote Services platform with certified IT security.
Service Contracts
Making maintenance costs calculable, reducing interfaces,
speeding up response times, and unburdening the company’s
resources – the reduced downtimes that these measures
achieve increase the productivity of a plant. Service contracts
from Siemens make maintenance and repairs more cost-effective and efficient. The service packages include local and remote maintenance for a system or product group in automation
and drive technology. Whether you need extended service periods, defined response times, or special maintenance intervals,
the services are compiled individually and according to need.
They can be adjusted flexibly at any time and used independently of each other. The expertise of Siemens’ specialists and
the capabilities of remote maintenance thus ensure reliable and
fast maintenance processes throughout a plant’s entire lifecycle.
13
http://support.automation.siemens.com/WW/view/en/65961857
Siemens D 81.8 · 04/2014
13/9
© Siemens AG 2014
Appendix
Indexes
Subject index
A
Additional axial load for motors in basic version .......................................2/14
Additional option recommended by the manufacturer –
Water & waste water ................................................................................12/12
Additional Terms and Conditions.............................................................13/18
Admissible cantilever forces at 50 Hz for motors with
reinforced bearings....................................................................................2/15
Ambient conditions ......................................................................................3/2
Answers for industry .......................................................................................2
Anti-freeze..................................................................................................3/12
Appendix ...................................................................................................13/1
Applicable standards and specifications ....................................................2/5
Application.............................................................................10/4, 12/4, 12/11
Application of SIMOTICS FD motor series...................................................1/4
Application-specific motors .......................................................................12/1
Article No. supplements and special versions ..........................................11/1
Article number code ....................................................................................1/6
Assignment of coupling types to SIMOTICS FD motors............................3/17
Axial load, additional, for motors in basic version .....................................2/14
B
Bearing assignment...................................................................................2/13
Bearing currents, reducing ..........................................................................2/7
Bearing lifetime (nominal lifetime)..............................................................2/13
Bearing system ..........................................................................................2/13
Bearings.....................................................................................................2/13
Benefits .............................................................................................10/4, 12/4
Benefits of SIMOTICS FD motor series........................................................1/4
Biocides .....................................................................................................3/12
13
C
Calculation of the start-up time for direct-on-line starting .........................2/10
Cantilever forces, admissible, at 50 Hz for motors with
reinforced bearings....................................................................................2/15
Catalog versions ..........................................................................................3/8
Catalog versions and special versions........................................................3/8
Catalogs for Industry Automation, Drive Technologies and
Low-Voltage Power Distribution ................................................................... U3
Certification – Explosion-proof motors.......................................................10/3
Chemical industry ....................................................................................12/10
Classification of zones – Explosion-proof motors ......................................10/2
Classification societies – Marine motors....................................................12/3
Condition monitoring system .....................................................................3/13
Conditions of sale and delivery ...............................................................13/18
Configuring ..................................................................................................3/2
Configuring the motor ..................................................................................3/2
Connection and terminal boxes.................................................................2/12
Terminal box mounting positions ...............................................................2/12
Terminal box position .................................................................................11/4
Converter-fed (1MM1, 1MH1, 1MQ1, 1MN1) or mains-fed
operation (1LH1) – Explosion-proof motors ...............................................10/5
Coolant temperature – Explosion-proof motors .........................................10/7
Cooling circuit in the application ...............................................................3/11
Cooling water quality .................................................................................3/11
Couplings...................................................................................................3/14
13/10
Siemens D 81.8 · 04/2014
D
Definite Purpose – SIMOTICS DP................................................................ 1/2
Design ......................................................................................................... 2/4
Dimensions ................................................... 4/22, 5/32, 6/34, 7/12, 8/12, 9/22
Dimensions Terminal boxes.......................... 4/24, 5/35, 6/36, 7/14, 8/14, 9/25
Dimensions Flanges ..................................... 4/23, 5/34, 6/35, 7/13, 8/13, 9/24
Dimensions Motors 1LH1/1MH1................................................................ 6/34
Dimensions Motors 1LL1 ........................................................................... 8/12
Dimensions Motors 1LM1/1MM1 ............................................................... 4/22
Dimensions Motors 1LN1/1MN1................................................................ 7/12
Dimensions Motors 1LP1........................................................................... 9/22
Dimensions Motors 1LP1 axially mounted equipment unit ....................... 9/23
Dimensions Motors 1LP1 radially mounted equipment unit ...................... 9/22
Dimensions Motors 1LQ1/1MQ1 axially mounted equipment unit ............ 5/33
Dimensions Motors 1LQ1/1MQ1 radially mounted equipment unit........... 5/32
Downloading Catalogs .............................................................................. 13/4
Duty types ................................................................................................... 3/2
E
Easy Shopping with the Industry Mall ....................................................... 13/3
EMC ........................................................................................................... 3/10
Energy & Environmental Services ............................................................. 13/8
Engineering the drive system ...................................................................... 3/3
Engineering the drive system – detail level 2 .............................................. 3/6
Essential additional options – Water & waste water ................................ 12/12
Explanation of the raw material/metal surcharges .................................. 13/15
Explanation of the raw material/metal surcharges for dysprosium
and neodym (rare earths)........................................................................ 13/16
Explosion Protected – SIMOTICS XP........................................................... 1/2
Explosion-proof motors.............................................................................. 10/1
Explosion-proof motors – Technical Information ....................................... 10/1
Export regulations ................................................................................... 13/18
F
Field Services ............................................................................................ 13/7
FLENDER couplings – Part of the drive system ........................................ 3/14
Flexible Duty – SIMOTICS FD...................................................................... 1/2
Forced-air cooled motors – enclosed version ............................................. 5/1
Forced-air cooled motors – open version.................................................... 9/1
Forced-air cooling ....................................................................................... 2/7
G
General information – Engineering the drive system .................................. 3/3
General information – Explosion-proof motors .......................................... 10/4
General Provisions................................................................................... 13/18
General Purpose – SIMOTICS GP ............................................................... 1/2
General technical specifications ................................................................. 1/5
Grease lifetime.................................................................................... 2/9, 2/14
H
Heat exchanger position ........................................................................... 11/5
High Torque – SIMOTICS HT ....................................................................... 1/2
Horizontal integration ..................................................................................... 8
Housing design – Marine motors .............................................................. 12/5
I
Index of article numbers.......................................................................... 13/13
Indexes .................................................................................................... 13/10
Industry Services....................................................................................... 13/5
Industry Services for the entire life cycle .................................................. 13/6
Information and Download Center Social Media, Mobile Media............... 13/4
Information and Ordering in the Internet and on DVD .............................. 13/3
Inhibitors, anti-freeze, biocides ................................................................. 3/12
Insulated bearings for converter-fed operation......................................... 2/14
Insulation ..................................................................................................... 2/6
Integrated Drive Systems ............................................................................... 8
Integration in the automation technology ....................................................... 8
Introduction.................................................................................................. 1/1
© Siemens AG 2014
Appendix
Indexes
Subject index
L
Lifecycle integration........................................................................................8
Load, mechanical ........................................................................................2/9
Lubrication .................................................................................................2/13
M
Marine applications ...................................................................................12/2
Materials in the motor cooling circuit .........................................................3/11
Materials used in the motor cooling circuit ................................................3/11
Maximum overload torques .........................................................................2/8
Mechanical limit speed..............................................................................11/6
Mechanical load ..........................................................................................2/9
Metal factor examples ..................................................................13/15, 13/16
Metal surcharges .....................................................................................13/15
Mobile Media .............................................................................................13/4
Modernization & Optimization Services.....................................................13/9
Modified windings – Special versions for non-standard voltage
or speed.....................................................................................................3/10
More information ..........................................................................................2/9
Motor connection .........................................................................................2/9
Motor connection – Marine motors ............................................................12/5
Motor protection...........................................................................................2/9
Motor protection – Marine motors ..............................................................12/7
Motors 1LH1 ................................................................................................1/2
Motors 1LH1/1MH1 for converter-fed operation ..........................................6/2
• Line voltage 400 V, 50 Hz ........................................................................6/2
- High Efficiency......................................................................................6/2
- Premium Efficiency ...............................................................................6/4
• Line voltage 460 V, 60 Hz ......................................................................6/14
- High Efficiency....................................................................................6/14
- Premium Efficiency .............................................................................6/16
• Line voltage 500 V, 50 Hz ........................................................................6/6
- High Efficiency......................................................................................6/6
- Premium Efficiency ...............................................................................6/8
• Line voltage 575 V, 60 Hz ......................................................................6/18
- High Efficiency....................................................................................6/18
- Premium Efficiency .............................................................................6/20
• Line voltage 690 V, 50 Hz ......................................................................6/10
- High Efficiency....................................................................................6/10
- Premium Efficiency .............................................................................6/12
Motors 1LH1/1MH1 for mains-fed operation .............................................6/22
• Line voltage 400 V, 50 Hz ......................................................................6/22
- High Efficiency....................................................................................6/22
- Premium Efficiency .............................................................................6/24
• Line voltage 460 V, 60 Hz ......................................................................6/30
- High Efficiency....................................................................................6/30
- Premium Efficiency .............................................................................6/32
• Line voltage 690 V, 50 Hz ......................................................................6/26
- High Efficiency....................................................................................6/26
- Premium Efficiency .............................................................................6/28
Motors 1LL1 .................................................................................................1/2
Motors 1LL1 for converter-fed operation .....................................................8/2
• Line Voltage 400 V, 50 Hz, High Efficiency..............................................8/2
• Line Voltage 460 V, 60 Hz, High Efficiency..............................................8/8
• Line Voltage 500 V, 50 Hz, High Efficiency..............................................8/4
• Line Voltage 575 V, 60 Hz, High Efficiency............................................8/10
• Line Voltage 690 V, 50 Hz, High Efficiency..............................................8/6
Motors 1LM1 ................................................................................................1/2
Motors 1LM1/1MM1 for converter-fed operation .........................................4/2
• Line voltage 400 V, 50 Hz ........................................................................4/2
- High Efficiency......................................................................................4/2
- Premium Efficiency ...............................................................................4/4
• Line voltage 460 V, 60 Hz ......................................................................4/14
- High Efficiency....................................................................................4/14
- Premium Efficiency .............................................................................4/16
• Line voltage 500 V, 50 Hz ........................................................................4/6
- High Efficiency......................................................................................4/6
- Premium Efficiency ...............................................................................4/8
• Line voltage 575 V, 60 Hz ......................................................................4/18
- High Efficiency....................................................................................4/18
- Premium Efficiency .............................................................................4/20
• Line voltage 690 V, 50 Hz ......................................................................4/10
- High Efficiency....................................................................................4/10
- Premium Efficiency .............................................................................4/12
Motors 1LN1 ................................................................................................ 1/3
Motors 1LN1/1MN1 for converter-fed operation.......................................... 7/2
• Line Voltage 400 V, 50 Hz, High Efficiency ............................................. 7/2
• Line Voltage 460 V, 60 Hz, High Efficiency ............................................. 7/8
• Line Voltage 500 V, 50 Hz, High Efficiency ............................................. 7/4
• Line Voltage 575 V, 60 Hz, High Efficiency ........................................... 7/10
• Line Voltage 690 V, 50 Hz, High Efficiency ............................................. 7/6
Motors 1LP1 ................................................................................................ 1/2
Motors 1LP1 for converter-fed operation..................................................... 9/2
• Line voltage 400 V, 50 Hz........................................................................ 9/2
- High Efficiency – low noise .................................................................. 9/2
- High Efficiency – increased output ...................................................... 9/4
• Line voltage 460 V, 60 Hz...................................................................... 9/14
- High Efficiency – low noise ................................................................ 9/14
- High Efficiency – increased output .................................................... 9/16
• Line voltage 500 V, 50 Hz........................................................................ 9/6
- High Efficiency – low noise .................................................................. 9/6
- High Efficiency – increased output ...................................................... 9/8
• Line voltage 575 V, 60 Hz...................................................................... 9/18
- High Efficiency – low noise ................................................................ 9/18
- High Efficiency – increased output .................................................... 9/20
• Line voltage 690 V, 50 Hz...................................................................... 9/10
- High Efficiency – low noise ................................................................ 9/10
- High Efficiency – increased output .................................................... 9/12
Motors 1LQ1 ................................................................................................ 1/2
Motors 1LQ1/1MQ1 ................................................................................... 5/32
Motors 1LQ1/1MQ1 for converter-fed operation ......................................... 5/2
• Line voltage 400 V, 50 Hz........................................................................ 5/2
- High Efficiency – low noise .................................................................. 5/2
- High Efficiency – increased output ...................................................... 5/4
- Premium Efficiency............................................................................... 5/6
• Line voltage 460 V, 60 Hz...................................................................... 5/20
- High Efficiency – low noise ................................................................ 5/20
- High Efficiency – increased output .................................................... 5/22
- Premium Efficiency............................................................................. 5/24
• Line voltage 500 V, 50 Hz........................................................................ 5/8
- High Efficiency – low noise .................................................................. 5/8
- High Efficiency – increased output .................................................... 5/10
- Premium Efficiency............................................................................. 5/12
• Line voltage 575 V, 60 Hz...................................................................... 5/26
- High Efficiency – low noise ................................................................ 5/26
- High Efficiency – increased output .................................................... 5/28
- Premium Efficiency............................................................................. 5/30
• Line voltage 690 V, 50 Hz...................................................................... 5/14
- High Efficiency – low noise ................................................................ 5/14
- High Efficiency – increased output .................................................... 5/16
- Premium Efficiency............................................................................. 5/18
Motors specially designed for converter-fed operation .............................. 2/6
Motors specially designed for mains-fed operation (1LH1) ........................ 2/9
N
Noise ........................................................................................................... 2/7
Noise emission for operation on SINAMICS converter.............................. 3/10
O
Offer and ordering processes for option package –
Water & waste water................................................................................ 12/11
Online Services ......................................................................................... 13/3
Online Support .......................................................................................... 13/6
Options ...................................................................................................... 11/7
Options Explosion-proof motors .............................................................. 11/20
Options for special environments – Chemical industry ........................... 12/10
Options Motors without explosion protection ............................................ 11/7
Ordering examples – Marine motors ......................................................... 12/8
Ordering notes – Marine motors................................................................ 12/7
Orientation ................................................................................................... 1/2
Overload torques, maximum ....................................................................... 2/8
Overview – Technical Information................................................................ 2/2
Overview of product lines............................................................................ 1/3
Overview of SIMOTICS FD 1MM, 1MH, 1MQ, 1MN explosion-proof
motors........................................................................................................ 10/3
Siemens D 81.8 · 04/2014
13/11
13
© Siemens AG 2014
Appendix
Indexes
Subject index
P
Paint finish – Marine motors.......................................................................12/7
Partners at Industry Automation and Drive Technologies .........................13/2
Percentage method .................................................................................13/15
Performance features of the SIMOTICS FD series ......................................1/3
Plant Maintenance & Condition Monitoring ...............................................13/9
Prices .......................................................................................................13/18
Product range for the water & waste water option packages –
Water & waste water ................................................................................12/11
Product Selection using the Interactive Catalog CA 01 of Industry ..........13/3
R
Rated motor speeds ....................................................................................3/8
Rated motor voltages according to line voltage and infeed........................3/6
Rated speeds ..............................................................................................3/8
Rated voltage...............................................................................................2/6
Rating plate..................................................................................................2/6
Rating plate and acceptance test certificate – Marine motors..................12/7
Recommended SINAMICS converters ........................................................3/8
Recommended special versions – Marine motors ....................................12/7
Reduced base-load currents IL of the SINAMICS converters .....................3/9
Reducing bearing currents ..........................................................................2/7
Regreasing ................................................................................................2/14
Regreasing intervals ..................................................................................2/14
Regulated infeed .........................................................................................3/4
Related catalogs.......................................................................................... U2
Repair Services..........................................................................................13/7
13
S
Self-ventilated motors – enclosed version ...................................................4/1
Self-ventilated motors – open version..........................................................8/1
Separately driven fan position ...................................................................11/5
Service Contracts ......................................................................................13/9
Severe Duty – SIMOTICS SD .......................................................................1/2
Shaft seal and degree of protection ..........................................................2/13
Siemens Industry Automation and Drive Technologies in the WWW.........13/3
Siemens Integrated Drive Systems............................................................3/14
SIMOTICS – Low-voltage motors for mains-fed and converter-fed
operation......................................................................................................1/2
SIMOTICS FD...............................................................................................3/2
SIMOTICS FD motor on alternative converters............................................3/7
SIMOTICS FD motor on SINAMICS converter .............................................3/7
SIMOTICS FD motor series..........................................................................2/2
Simple motor selection – detail level 1 ........................................................3/6
SINAMICS converters, recommended ........................................................3/8
Single-joint couplings ................................................................................3/15
SIPLUS CMS condition monitoring systems for the continuous
condition monitoring of motors ..................................................................3/13
Site altitude ..................................................................................................3/2
Social Media ..............................................................................................13/4
Spare Parts ................................................................................................13/7
Special technology – Explosion-proof motors ...........................................10/7
Special versions................................................................................3/10, 11/1
Specifications ..............................................................................................2/5
Specifications of the individual classification societies with
order codes for ordering SIMOTICS FD motors in marine design.............12/5
Standards ....................................................................................................2/5
Start-up procedure for three-phase motors with squirrel-cage rotor .........2/11
Start-up time for direct-on-line starting, calculation...................................2/10
Structure of catalog motor selection tables .................................................3/2
Structure of the article numbers for motors .................................................1/6
Structure of the metal factor .........................................................13/15, 13/16
Subject index ...........................................................................................13/10
Surcharge calculation ...................................................................13/15, 13/16
System Components....................................................................................3/1
13/12
Siemens D 81.8 · 04/2014
T
Technical Consulting & Engineering Support............................................ 13/8
Technical content of the option package – Water & waste water............ 12/12
Technical Information .................................................................................. 2/1
Technical Information – Explosion-proof motors ....................................... 10/2
Technical specifications ............................................................ 2/5, 10/4, 12/5
Technical Support...................................................................................... 13/6
Temperature class and coolant temperature – Marine motors.................. 12/6
The basic design of the SIMOTICS FD motor series................................... 2/4
The SIMOTICS family of motors .................................................................. 1/2
Thermal torque limits (continuous duty) ...................................................... 2/8
Three-month average price ..................................................................... 13/16
Torque characteristic ................................................................................... 2/9
Totally Integrated Automation (TIA) ................................................................ 4
Totally Integrated Power (TIP) ........................................................................ 6
Training ...................................................................................................... 13/8
Transnorm – SIMOTICS TN.......................................................................... 1/2
Two-joint couplings.................................................................................... 3/15
Type of protection Ex nA for use in Zone 2 – Explosion-proof motors....... 10/4
Type of protection Ex tc for use in Zone 22 – Explosion-proof motors ...... 10/4
Types of construction ................................................................................ 11/3
Types of protection – Explosion-proof motors ........................................... 10/2
U
Unregulated infeed...................................................................................... 3/3
V
Values of the metal factor ........................................................................ 13/17
Versions of the SIMOTICS FD motor series ................................................. 2/2
VIK version ..................................................................................... 10/7, 12/10
Voltage supply via the converter ................................................................. 3/3
Voltages ..................................................................................................... 11/2
W
Water & waste water................................................................................ 12/11
Water cooling...................................................................................... 2/9, 12/5
Water cooling (1LH1 and 1LN1 motors).................................................... 3/11
Water-cooled motors with air-to-water heat exchanger............................... 7/1
Water-cooled motors with water-jacket cooling........................................... 6/1
Weight method ............................................................................. 13/15, 13/16
Winding and motor protection – Marine motors ........................................ 12/7
© Siemens AG 2014
Appendix
Indexes
Index of article numbers
1LH1
1LH1202-3A… ........................................................................6/22, 6/26, 6/30
1LH1202-3B… ........................................................................6/22, 6/26, 6/30
1LH1203-3A… ........................................................................6/24, 6/28, 6/32
1LH1203-3B… ........................................................................6/24, 6/28, 6/32
1LH1212-3A… ..........................................................6/2, 6/6, 6/10, 6/14, 6/18
1LH1212-3B... ...........................................................6/2, 6/6, 6/10, 6/14, 6/18
1LH1213-3A… ..........................................................6/4, 6/8, 6/12, 6/16, 6/20
1LH1213-3B… ..........................................................6/4, 6/8, 6/12, 6/16, 6/20
1LH1222-3A… ..........................................................6/2, 6/6, 6/10, 6/14, 6/18
1LH1222-3B… ..........................................................6/2, 6/6, 6/10, 6/14, 6/18
1LH1223-3A… ..........................................................6/4, 6/8, 6/12, 6/16, 6/20
1LH1223-3B… ..........................................................6/4, 6/8, 6/12, 6/16, 6/20
1MH1
1MH1202-3A…
1MH1202-3B…
1MH1203-3A…
1MH1203-3B…
1MH1212-3A…
1MH1212-3B...
1MH1213-3A…
1MH1213-3B…
1MH1222-3A…
1MH1222-3B…
1MH1223-3A…
1MH1223-3B…
....................................................................... 6/22, 6/26, 6/30
....................................................................... 6/22, 6/26, 6/30
....................................................................... 6/24, 6/28, 6/32
....................................................................... 6/24, 6/28, 6/32
......................................................... 6/2, 6/6, 6/10, 6/14, 6/18
......................................................... 6/2, 6/6, 6/10, 6/14, 6/18
......................................................... 6/4, 6/8, 6/12, 6/16, 6/20
......................................................... 6/4, 6/8, 6/12, 6/16, 6/20
......................................................... 6/2, 6/6, 6/10, 6/14, 6/18
......................................................... 6/2, 6/6, 6/10, 6/14, 6/18
......................................................... 6/4, 6/8, 6/12, 6/16, 6/20
......................................................... 6/4, 6/8, 6/12, 6/16, 6/20
1LL1
1LL1212-3A…
1LL1212-3B…
1LL1222-3A…
1LL1222-3B…
...............................................................8/2, 8/4, 8/6, 8/8, 8/10
...............................................................8/2, 8/4, 8/6, 8/8, 8/10
...............................................................8/2, 8/4, 8/6, 8/8, 8/10
...............................................................8/2, 8/4, 8/6, 8/8, 8/10
1ML1
1ML1212-3A…
1ML1212-3B…
1ML1222-3A…
1ML1222-3B…
............................................................. 8/2, 8/4, 8/6, 8/8, 8/10
............................................................. 8/2, 8/4, 8/6, 8/8, 8/10
............................................................. 8/2, 8/4, 8/6, 8/8, 8/10
............................................................. 8/2, 8/4, 8/6, 8/8, 8/10
1LM1
1LM1212-3A…
1LM1212-3B…
1LM1213-3A…
1LM1213-3B…
1LM1222-3A…
1LM1222-3B…
1LM1223-3A…
1LM1223-3B…
..........................................................4/2, 4/6, 4/10, 4/14, 4/18
..........................................................4/2, 4/6, 4/10, 4/14, 4/18
..........................................................4/4, 4/8, 4/12, 4/16, 4/20
..........................................................4/4, 4/8, 4/12, 4/16, 4/20
..........................................................4/2, 4/6, 4/10, 4/14, 4/18
..........................................................4/2, 4/6, 4/10, 4/14, 4/18
..........................................................4/4, 4/8, 4/12, 4/16, 4/20
..........................................................4/4, 4/8, 4/12, 4/16, 4/20
1MM1
1MM1212-3A…
1MM1212-3B…
1MM1213-3A…
1MM1213-3B…
1MM1222-3A…
1MM1222-3B…
1MM1223-3A…
1MM1223-3B…
........................................................ 4/2, 4/6, 4/10, 4/14, 4/18
........................................................ 4/2, 4/6, 4/10, 4/14, 4/18
........................................................ 4/4, 4/8, 4/12, 4/16, 4/20
........................................................ 4/4, 4/8, 4/12, 4/16, 4/20
........................................................ 4/2, 4/6, 4/10, 4/14, 4/18
........................................................ 4/2, 4/6, 4/10, 4/14, 4/18
........................................................ 4/4, 4/8, 4/12, 4/16, 4/20
........................................................ 4/4, 4/8, 4/12, 4/16, 4/20
1LN1
1LN1212-3A…
1LN1212-3B…
1LN1222-3A…
1LN1222-3B…
..............................................................7/2, 7/4, 7/6, 7/8, 7/10
..............................................................7/2, 7/4, 7/6, 7/8, 7/10
..............................................................7/2, 7/4, 7/6, 7/8, 7/10
..............................................................7/2, 7/4, 7/6, 7/8, 7/10
1LP1
1LP1212-3A…
1LP1212-3B…
1LP1222-3A…
1LP1222-3B…
1LP1312-3A…
1LP1312-3B…
1LP1322-3A…
1LP1322-3B…
...........................................................9/2, 9/6, 9/10, 9/14, 9/18
...........................................................9/2, 9/6, 9/10, 9/14, 9/18
...........................................................9/2, 9/6, 9/10, 9/14, 9/18
...........................................................9/2, 9/6, 9/10, 9/14, 9/18
...........................................................9/4, 9/8, 9/12, 9/16, 9/20
...........................................................9/4, 9/8, 9/12, 9/16, 9/20
...........................................................9/4, 9/8, 9/12, 9/16, 9/20
...........................................................9/4, 9/8, 9/12, 9/16, 9/20
1MQ1
1MQ1212-3A…
1MQ1212-3B…
1MQ1213-3A…
1MQ1213-3B…
1MQ1222-3A…
1MQ1222-3B…
1MQ1223-3A…
1MQ1223-3B…
1MQ1312-3A…
1MQ1312-3B…
1MQ1322-3A…
1MQ1322-3B…
......................................................... 5/2, 5/8, 5/14, 5/20, 5/26
......................................................... 5/2, 5/8, 5/14, 5/20, 5/26
....................................................... 5/6, 5/12, 5/18, 5/24, 5/30
....................................................... 5/6, 5/12, 5/18, 5/24, 5/30
......................................................... 5/2, 5/8, 5/14, 5/20, 5/26
......................................................... 5/2, 5/8, 5/14, 5/20, 5/26
....................................................... 5/6, 5/12, 5/18, 5/24, 5/30
....................................................... 5/6, 5/12, 5/18, 5/24, 5/30
....................................................... 5/4, 5/10, 5/16, 5/22, 5/28
....................................................... 5/4, 5/10, 5/16, 5/22, 5/28
....................................................... 5/4, 5/10, 5/16, 5/22, 5/28
....................................................... 5/4, 5/10, 5/16, 5/22, 5/28
1LQ1
1LQ1212-3A…
1LQ1212-3B…
1LQ1213-3A…
1LQ1213-3B…
1LQ1222-3A…
1LQ1222-3B…
1LQ1223-3A…
1LQ1223-3B…
1LQ1312-3A…
1LQ1312-3B…
1LQ1322-3A…
1LQ1322-3B…
..........................................................5/2, 5/8, 5/14, 5/20, 5/26
..........................................................5/2, 5/8, 5/14, 5/20, 5/26
........................................................5/6, 5/12, 5/18, 5/24, 5/30
........................................................5/6, 5/12, 5/18, 5/24, 5/30
..........................................................5/2, 5/8, 5/14, 5/20, 5/26
..........................................................5/2, 5/8, 5/14, 5/20, 5/26
........................................................5/6, 5/12, 5/18, 5/24, 5/30
........................................................5/6, 5/12, 5/18, 5/24, 5/30
........................................................5/4, 5/10, 5/16, 5/22, 5/28
........................................................5/4, 5/10, 5/16, 5/22, 5/28
........................................................5/4, 5/10, 5/16, 5/22, 5/28
........................................................5/4, 5/10, 5/16, 5/22, 5/28
6SL3370-7PE..
6SL3370-1PE36-6AA0 ......................................................... 4/3, 4/5, 4/15, 8/3
6SL3710-1GE..
6SL3710-1GE32-6AA3 ............................................................................... 4/7
6SL3710-1GE33-1AA3 ........................................ 4/7, 4/9, 5/9, 5/11, 5/13, 6/9
6SL3710-1GE33-8AA3 ................................ 4/3, 4/5, 4/7, 4/15, 5/3, 5/9, 5/11,
................................................................................ 5/21, 6/7, 6/9, 7/5, 8/5, 9/7
6SL3710-1GE35-0AA3 ......................... 4/3, 4/5, 4/7, 4/9, 4/15, 4/17, 5/3, 5/5,
......................................................... 5/7, 5/9, 5/11, 5/13, 5/21, 5/23, 5/25, 6/3,
............................................................... 6/5, 6/7, 6/9, 6/15, 6/17, 7/3, 7/5, 7/9,
......................................................................... 8/3, 8/5, 8/9, 9/3, 9/7, 9/9, 9/15
6SL3710-1GE36-1AA3 ......................... 4/3, 4/5, 4/7, 4/9, 4/15, 4/17, 5/3, 5/5,
......................................................... 5/7, 5/9, 5/11, 5/13, 5/21, 5/23, 5/25, 6/3,
............................................................... 6/5, 6/7, 6/9, 6/15, 6/17, 7/3, 7/5, 7/9,
......................................................... 8/3, 8/5, 8/9, 9/3, 9/5, 9/7, 9/9, 9/15, 9/17
6SL3710-1GE37-5AA3 ......................... 4/3, 4/5, 4/7, 4/9, 4/15, 4/17, 5/3, 5/5,
......................................................... 5/7, 5/9, 5/11, 5/13, 5/21, 5/23, 5/25, 6/3,
............................................................... 6/5, 6/7, 6/9, 6/15, 6/17, 7/3, 7/5, 7/9,
......................................................... 8/3, 8/5, 8/9, 9/3, 9/5, 9/7, 9/9, 9/15, 9/17
6SL3710-1GE38-4AA3 ......................... 4/3, 4/5, 4/9, 4/15, 4/17, 5/3, 5/5, 5/7,
........................................................... 5/11, 5/21, 5/23, 5/25, 6/3, 6/5, 6/7, 6/9,
............................................................... 6/15, 6/17, 7/3, 7/5, 7/9, 8/3, 8/5, 8/9,
.............................................................................. 9/3, 9/5, 9/7, 9/9, 9/15, 9/17
6SL3710-1GE41-0AA3 ....................... 4/3, 4/5, 4/15, 4/17, 5/3, 5/5, 5/7, 5/23,
............................................................. 5/25, 6/3, 6/5, 6/7, 6/9, 6/15, 6/17, 7/3,
................................................................... 7/5, 7/9, 8/3, 8/5, 8/9, 9/3, 9/5, 9/7,
................................................................................................... 9/9, 9/15, 9/17
Siemens D 81.8 · 04/2014
13/13
13
© Siemens AG 2014
Appendix
Indexes
Index of article numbers
6SL3710-1GF..
6SL3710-1GF32-2AA3 .......................................................................3/9, 4/21
6SL3710-1GF32-6AA3 .....................................................................4/19, 4/21
6SL3710-1GF33-3AA3 ........................4/19, 5/27, 5/29, 5/31, 6/19, 6/21, 8/11
6SL3710-1GF34-1AA3 ................................4/19, 4/21, 5/27, 5/29, 5/31, 6/19,
........................................................................................7/11, 8/11, 9/19, 9/21
6SL3710-1GF34-7AA3 ................................4/19, 4/21, 5/27, 5/29, 5/31, 6/19,
...............................................................................6/21, 7/11, 8/11, 9/19, 9/21
6SL3710-1GF35-8AA3 ................................4/19, 4/21, 5/27, 5/29, 5/31, 6/19,
...............................................................................6/21, 7/11, 8/11, 9/19, 9/21
6SL3710-1GF37-4AA3 ................................4/19, 4/21, 5/27, 5/29, 5/31, 6/19,
...............................................................................6/21, 7/11, 8/11, 9/19, 9/21
6SL3710-1GF38-1AA3 .................................6/19, 6/21, 7/11, 8/11, 9/19, 9/21
6SL3710-1GH..
6SL3710-1GH31-8AA3 ....................................................................4/11, 4/13
6SL3710-1GH32-..A3 ................................................................................6/13
6SL3710-1GH32-2AA3 .........................4/11, 4/13, 5/15, 5/17, 5/19, 6/11, 8/7
6SL3710-1GH32-6AA3 .........4/11, 4/13, 5/15, 5/17, 6/13, 7/7, 8/7, 9/11, 9/13
6SL3710-1GH33-..A3 ................................................................................6/13
6SL3710-1GH33-3AA3 ...............................4/11, 4/13, 5/15, 5/17, 5/19, 6/11,
...................................................................................6/13, 7/7, 8/7, 9/11, 9/13
6SL3710-1GH34-..A3 ................................................................................6/13
6SL3710-1GH34-1AA3 ...............................4/11, 4/13, 5/15, 5/17, 5/19, 6/11,
...................................................................................6/13, 7/7, 8/7, 9/11, 9/13
6SL3710-1GH34-7AA3 ........................................4/11, 5/15, 5/17, 5/19, 6/11,
...................................................................................6/13, 7/7, 8/7, 9/11, 9/13
6SL3710-1GH35-8AA3 .........4/11, 4/13, 5/17, 5/19, 6/11, 7/7, 8/7, 9/11, 9/13
6SL3710-1GH37-4AA3 ....................................6/11, 6/13, 7/7, 8/7, 9/11, 9/13
6SL3710-1GH38-1AA3 .............................................................................9/13
6SL3710-1PE33-7AA0 ................................................................4/3, 4/5, 4/15
6SL3710-1PE34-6AA0 .......................................................4/3, 4/15, 4/17, 8/3
6SL3710-1PE35-8AA0 ................................................4/3, 4/5, 4/15, 4/17, 8/3
6SL3710-1PE37-4AA0 ................................................4/3, 4/5, 4/15, 4/17, 8/3
6SL3710-2GE..
6SL3710-2GE41-1AA3 ..........................6/3, 6/5, 6/15, 6/17, 7/3, 7/5, 7/9, 8/3,
................................................................8/5, 8/9, 9/3, 9/5, 9/7, 9/9, 9/15, 9/17
6SL3710-2GE41-4AA3 ...................................6/3, 6/5, 6/17, 7/3, 7/9, 8/3, 8/9,
.....................................................................................9/3, 9/5, 9/9, 9/15, 9/17
6SL3710-2GE41-6AA3 ................................................................8/3, 9/5, 9/17
6SL3710-2GF..
6SL3710-2GF38-6AA3 ............................................................8/11, 9/19, 9/21
6SL3710-2GF41-1AA3 ...................................................7/11, 8/11, 9/19, 9/21
13
13/14
Siemens D 81.8 · 04/2014
6SL3710-7LE..
6SL3710-7LE33-1AA3 ................................. 4/3, 4/5, 4/15, 5/3, 4/17, 5/5, 5/7,
............................................................................ 5/21, 5/23, 5/25, 6/3, 6/5, 8/3
6SL3710-7LE35-0AA3 ........................ 4/3, 4/5, 4/15, 4/17, 5/3, 5/5, 5/7, 5/21,
........................................................... 5/23, 5/25, 6/3, 6/15, 6/17, 7/3, 7/9, 8/3,
..................................................................................... 8/9, 9/3, 9/5, 9/15, 9/17
6SL3710-7LE36-1AA3 ........................ 4/3, 4/5, 4/15, 4/17, 5/3, 5/5, 5/7, 5/21,
........................................................... 5/23, 5/25, 6/3, 6/5, 6/15, 6/17, 7/3, 7/9,
.............................................................................. 8/3, 8/9, 9/3, 9/5, 9/15, 9/17
6SL3710-7LE37-5AA3 ........................ 4/3, 4/5, 4/15, 4/17, 5/3, 5/5, 5/7, 5/21,
........................................................... 5/23, 5/25, 6/3, 6/5, 6/15, 6/17, 7/3, 7/9,
.............................................................................. 8/3, 8/9, 9/3, 9/5, 9/15, 9/17
6SL3710-7LE38-4AA3 ........................ 4/3, 4/5, 4/15, 4/17, 5/3, 5/5, 5/7, 5/23,
............................................................... 5/25, 6/3, 6/5, 6/15, 7/3, 7/9, 8/3, 8/9,
............................................................................................ 9/3, 9/5, 9/15, 9/17
6SL3710-7LE41-0AA3 ................................. 6/3, 6/5, 6/15, 6/17, 7/3, 7/9, 8/3,
..................................................................................... 8/9, 9/3, 9/5, 9/15, 9/17
6SL3710-7LE41-2AA3 .......................................... 6/3, 6/5, 6/17, 7/3, 7/9, 8/3,
..................................................................................... 8/9, 9/3, 9/5, 9/15, 9/17
6SL3710-7LG..
6SL3710-7LG31-5AA3 ............................................................................. 4/11
6SL3710-7LG31-8AA3 ......................................... 4/11, 4/13, 4/21, 5/15, 5/17
6SL3710-7LG32-2AA3 .......................................... 4/7, 4/11, 4/13, 4/19, 5/15,
................................................................................. 5/19, 6/11, 6/13, 6/13, 8/7
6SL3710-7LG32-6AA3 ............................ 4/7, 4/9, 4/11, 4/13, 4/19, 5/9, 5/13,
..................................................................... 5/15, 5/17, 5/19, 5/29, 6/11, 6/13,
............................................................................................ 7/7, 8/7, 9/11, 9/13
6SL3710-7LG33-3AA3 ................... 4/7, 4/9, 4/11, 4/13, 4/19, 4/21, 5/9, 5/11,
..................................................... 5/13, 5/15, 5/17, 5/19, 5/27, 5/29, 5/31, 6/7,
......................................................... 6/9, 6/11, 6/13, 6/19, 6/21, 7/5, 7/7, 7/11,
.......................................................... 8/5, 8/7, 8/11, 9/7, 9/11, 9/13, 9/19, 9/21
6SL3710-7LG34-1AA3 ................... 4/7, 4/9, 4/11, 4/13, 4/19, 4/21, 5/9, 5/11,
..................................................... 5/13, 5/15, 5/17, 5/19, 5/27, 5/29, 5/31, 6/7,
......................................................... 6/9, 6/11, 6/13, 6/19, 6/21, 7/5, 7/7, 7/11,
................................................... 8/5, 8/7, 8/11, 9/7, 9/9, 9/11, 9/13, 9/19, 9/21
6SL3710-7LG34-7AA3 ................. 4/7, 4/11, 4/13, 4/19, 4/21, 5/9, 5/11, 5/13,
....................................................... 5/15, 5/17, 5/19, 5/27, 5/29, 5/31, 6/7, 6/9,
......................................................... 6/11, 6/13, 6/19, 6/21, 7/5, 7/7, 7/11, 8/5,
.......................................................... 8/7, 8/11, 9/7, 9/9, 9/11, 9/13, 9/19, 9/21
6SL3710-7LG35-8AA3 ................... 4/7, 4/9, 4/19, 4/21, 5/9, 5/11, 5/13, 5/17,
....................................................... 5/27, 5/29, 5/31, 6/7, 6/9, 6/11, 6/19, 6/21,
............................................................... 7/5, 7/7, 7/11, 8/5, 8/7, 8/11, 9/7, 9/9,
........................................................................................ 9/11, 9/13, 9/19, 9/21
6SL3710-7LG37-4AA3 ................... 4/7, 4/9, 4/19, 4/21, 5/9, 5/11, 5/13, 5/29,
.................................................... 5/31, 6/7, 6/9, 6/19, 6/21, 7/5, 7/7, 7/11, 8/5,
.......................................................... 8/7, 8/11, 9/7, 9/9, 9/11, 9/13, 9/19, 9/21
6SL3710-7LG38-1AA3 ..................................... 6/7, 6/9, 6/19, 6/21, 7/5, 7/11,
............................................................................ 8/5, 8/11, 9/7, 9/9, 9/19, 9/21
6SL3710-7LG38-8AA3 ........ 6/7, 6/9, 7/5, 7/11, 8/5, 8/11, 9/7, 9/9, 9/19, 9/21
6SL3710-7LG41-0AA3 ...................... 7/5, 7/11, 8/5, 8/11, 9/7, 9/9, 9/19, 9/21
6SL3710-7LG41-3AA3 ............................................................................... 9/9
© Siemens AG 2014
Appendix
Metal surcharges
■ Explanation of the raw material/metal surcharges 1) 2) 3) 4)
Surcharge calculation
To compensate for variations in the price of the raw materials
silver, copper, aluminum, lead, gold, dysprosium 2) and/or
neodym 2), surcharges are calculated on a daily basis using the
so-called metal factor for products containing these raw
materials. A surcharge for the respective raw material is calculated as a supplement to the price of a product if the basic
official price of the raw material in question is exceeded.
The surcharges are calculated in accordance with the following
criteria:
• Basic official price of the raw material
Basic official price from the day prior to receipt of the order or
prior to release order (daily price) for 3)
- Silver (sales price, processed)
- Gold (sales price, processed)
Percentage method
Use of the percentage method is indicated by the letters A-Z at
the respective digit of the metal factor.
The surcharge is increased – dependent on the deviation of the
daily price compared with the basic official price – using the percentage method in "steps" and consequently offers surcharges
that remain constant within the framework of this "step range". A
higher percentage rate is charged for each new step. The respective percentage level can be found in the table below.
Metal factor examples
LEA–––––
Basis for % surcharge: List price
Silver Basis 150 €, Step 50 €, 0.5 %
4)
and for
- Copper (lower DEL notation + 1 %)
- Aluminum (aluminum in cables)
- Lead (lead in cables)
• Metal factor of the products
Certain products are displayed with a metal factor. The metal
factor determines the official price (for those raw materials
concerned) as of which the metal surcharges are applied and
the calculation method used (weight or percentage method).
An exact explanation is given below.
Copper Basis 150 €, Step 50 €, 0.1 %
No surcharge for aluminum
No surcharge for lead
No surcharge for gold
No surcharge for dysprosium
No surcharge for neodym
N –A6 ––––
Structure of the metal factor
Basis for % surcharge: Customer net price
The metal factor consists of several digits; the first digit indicates
whether the percentage method of calculation refers to the list
price or a possible discounted price (customer net price) (L = list
price / N = customer net price).
No surcharge for silver
Copper Basis 150 €, Step 50 €, 0.1 %
Aluminum acc. to weight, basic offic. price 225 €
The remaining digits indicate the method of calculation used for
the respective raw material. If no surcharge is added for a raw
material, a "-" is used.
No surcharge for lead
No surcharge for gold
No surcharge for dysprosium
1st digit
List or customer net price using the percentage method
2nd digit
for silver (AG)
3rd digit
for copper (CU)
4th digit
for aluminum (AL)
No basis necessary
5th digit
for lead (PB)
No surcharge for silver
6th digit
for gold (AU)
Copper acc. to weight, basic official price 150 €
7th digit
for dysprosium (Dy) 2)
No surcharge for aluminum
8th digit
for neodym (Nd) 2)
No surcharge for lead
No surcharge for neodym
– –3 – – – – –
No surcharge for gold
Weight method
The weight method uses the basic official price, the daily price
and the raw material weight. In order to calculate the surcharge,
the basic official price must be subtracted from the daily price.
The difference is then multiplied by the raw material weight.
No surcharge for dysprosium
No surcharge for neodym
13
The basic official price can be found in the table below using the
number (1 to 9) of the respective digit of the metal factor. The raw
material weight can be found in the respective product descriptions.
1)
2)
3)
4)
Refer to the separate explanation on the next page regarding the raw materials dysprosium and neodym (= rare earths).
For a different method of calculation, refer to the separate explanation for these raw materials on the next page.
Source: Umicore, Hanau (www.metalsmanagement.umicore.com).
Source: German Trade Association for Cables and Conductors (www.kabelverband.org).
Siemens D 81.8 · 04/2014
13/15
© Siemens AG 2014
Appendix
Metal surcharges
■ Explanation of the raw material/metal surcharges for dysprosium and neodym (rare earths)1) 2)
Surcharge calculation
To compensate for variations in the price of the raw materials
silver 1), copper 1), aluminum 1), lead 1), gold 1), dysprosium
and/or neodym, surcharges are calculated on a daily basis
using the so-called metal factor for products containing these
raw materials. The surcharge for dysprosium and neodym is
calculated as a supplement to the price of a product if the basic
official price of the raw material in question is exceeded.
The surcharge is calculated in accordance with the following
criteria:
• Basic official price of the raw material 2)
Three-month basic average price (see below) in the period
before the quarter in which the order was received or the
release order took place (= average official price) for
- dysprosium (Dy metal, 99 % min. FOB China; USD/kg)
- neodym (Nd metal, 99 % min. FOB China; USD/kg)
• Metal factor of the products
Certain products are displayed with a metal factor. The metal
factor indicates (for those raw materials concerned) the basic
official price as of which the surcharges for dysprosium and
neodym are calculated using the weight method. An exact
explanation of the metal factor is given below.
Three-month average price
The prices of rare earths vary according to the foreign currency,
and there is no freely accessible stock exchange listing. This
makes it more difficult for all parties involved to monitor changes
in price. In order to avoid continuous adjustment of the surcharges, but to still ensure fair, transparent pricing, an average
price is calculated over a three-month period using the average
monthly foreign exchange rate from USD to EUR (source: European Central Bank). Since not all facts are immediately available
at the start of each month, a one-month buffer is allowed before
the new average price applies.
Structure of the metal factor
The metal factor consists of several digits; the first digit is not
relevant to the calculation of dysprosium and neodym.
The remaining digits indicate the method of calculation used for
the respective raw material. If no surcharge is added for a raw
material, a "-" is used.
1st digit
List or customer net price using the percentage method
2nd digit
for silver (AG) 1)
3rd digit
for copper (CU) 1)
4th digit
for aluminum (AL) 1)
5th digit
for lead (PB) 1)
6th digit
for gold (AU) 1)
7th digit
for dysprosium (Dy)
8th digit
for neodym (Nd)
Weight method
The weight method uses the basic official price, the average
price and the raw material weight. In order to calculate the
surcharge, the basic official price must be subtracted from the
average price. The difference is then multiplied by the raw
material weight.
The basic official price can be found in the table below using the
number (1 to 9) of the respective digit of the metal factor. Your
Sales contact can inform you of the raw material weight.
Metal factor examples
––––––71
No basis necessary
Examples of calculation of the average official price:
No surcharge for silver
Period for calculation of
the average price:
Period during which the order/release order is
effected and the average price applies:
No surcharge for copper
Sep 2012 – Nov 2012
Q1 in 2013 (Jan – Mar)
Dec 2012 – Feb 2013
Q2 in 2013 (Apr – Jun)
Mar 2013 – May 2013
Q3 in 2013 (Jul – Sep)
Jun 2013 – Aug 2013
Q4 in 2013 (Oct – Dec)
No surcharge for aluminum
No surcharge for lead
No surcharge for gold
Dysprosium acc. to weight, basic official price
300 €
Neodym acc. to weight, basic official price 50 €
13
1)
2)
For a different method of calculation, refer to the separate explanation for these raw materials on the previous page.
Source: Asian Metal Ltd (www.asianmetal.com)
13/16
Siemens D 81.8 · 04/2014
© Siemens AG 2014
Appendix
Metal surcharges
■ Values of the metal factor
Percentage
method
Basic official Step range
price
in €
in €
% surcharge
1st step
% surcharge
2nd step
% surcharge
3rd step
% surcharge
4th step
Price in €
Price in €
Price in €
Price in €
% surcharge
per additional step
150.01 – 200.00
200.01 – 250.00
250.01 – 300.00
300.01 – 350.00
A
150
50
0.1
0.2
0.3
0.4
0.1
B
150
50
0.2
0.4
0.6
0.8
0.2
C
150
50
0.3
0.6
0.9
1.2
0.3
D
150
50
0.4
0.8
1.2
1.6
0.4
E
150
50
0.5
1.0
1.5
2.0
0.5
F
150
50
0.6
1.2
1.8
2.4
0.6
G
150
50
1.0
2.0
3.0
4.0
1.0
H
150
50
1.2
2.4
3.6
4.8
1.2
I
150
50
1.6
3.2
4.8
6.4
1.6
J
150
50
1.8
3.6
5.4
7.2
1.8
175.01 – 225.00
225.01 – 275.00
275.01 – 325.00
325.01 – 375.00
O
175
50
0.1
0.2
0.3
0.4
0.1
P
175
50
0.2
0.4
0.6
0.8
0.2
R
175
50
0.5
1.0
1.5
2.0
0.5
225.01 – 275.00
275.01 – 325.00
325.01 – 375.00
375.01 – 425.00
S
225
50
0.2
0.4
0.6
0.8
0.2
U
225
50
1.0
2.0
3.0
4.0
1.0
V
225
50
1.0
1.5
2.0
3.0
1.0
W
225
50
1.0
Y
Z
150
400
25
25
1.2
2.5
3.5
4.5
150.01 – 175.00
175.01 – 200.00
200.01 – 225.00
225.01 – 250.00
0.3
0.6
0.9
1.2
400.01 – 425.00
425.01 – 450.00
450.01 – 475.00
475.01 – 500.00
0.1
0.2
0.3
0.4
0.3
0.1
Price basis (1st digit)
L
Calculation based on the list price
N
Calculation based on the customer net price (discounted list price)
Weight
method
Basic official price in €
1
50
2
100
3
150
4
175
5
200
6
225
7
300
8
400
9
555
Calculation based on raw material weight
13
Miscellaneous
-
No metal surcharge
Siemens D 81.8 · 04/2014
13/17
© Siemens AG 2014
Appendix
Conditions of sale and delivery
■ 1. General Provisions
By using this catalog you can acquire hardware and software
products described therein from Siemens AG subject to the
following Terms and Conditions of Sale and Delivery (hereinafter
referred to as "T&C"). Please note that the scope, the quality and
the conditions for supplies and services, including software
products, by any Siemens entity having a registered office
outside Germany, shall be subject exclusively to the General
Terms and Conditions of the respective Siemens entity. The
following T&C apply exclusively for orders placed with Siemens
Aktiengesellschaft, Germany.
1.1 For customers with a seat or registered office in
Germany
For customers with a seat or registered office in Germany, the
following applies subordinate to the T&C:
• the "General Terms of Payment" 1) and,
• for software products, the "General License Conditions for
Software Products for Automation and Drives for Customers
with a Seat or Registered Office in Germany" 1) and,
• for other supplies and services, the "General Conditions for
the Supply of Products and Services of the Electrical and
Electronics Industry" 1).
1.2 For customers with a seat or registered office outside
Germany
For customers with a seat or registered office outside Germany,
the following applies subordinate to the T&C:
• the "General Terms of Payment" 1) and,
• for software products, the "General License Conditions for
Software Products for Automation and Drives for Customers
with a Seat or Registered Office outside of Germany" 1) and
• for other supplies and/or services, the "General Conditions for
Supplies of Siemens Industry for Customers with a Seat or
Registered Office outside of Germany" 1).
■ 2. Prices
13
The prices are in € (Euro) ex point of delivery, exclusive of
packaging.
The sales tax (value added tax) is not included in the prices. It
shall be charged separately at the respective rate according to
the applicable statutory legal regulations.
Prices are subject to change without prior notice. We will charge
the prices valid at the time of delivery.
To compensate for variations in the price of raw materials (e.g.
silver, copper, aluminum, lead, gold, dysprosium and neodym),
surcharges are calculated on a daily basis using the so-called
metal factor for products containing these raw materials. A
surcharge for the respective raw material is calculated as a
supplement to the price of a product if the basic official price of
the raw material in question is exceeded.
The metal factor of a product indicates the basic official price
(for those raw materials concerned) as of which the surcharges
on the price of the product are applied, and with what method of
calculation.
You will find a detailed explanation of the metal factor on the
page headed "Metal surcharges".
To calculate the surcharge (except in the cases of dysprosium
and neodym), the official price from the day prior to that on which
the order was received or the release order was effected is used.
To calculate the surcharge applicable to dysprosium and
neodym ("rare earths"), the corresponding three-month basic
average price in the quarter prior to that in which the order was
received or the release order was effected is used with a onemonth buffer (details on the calculation can be found in the
explanation of the metal factor).
13/18
Siemens D 81.8 · 04/2014
■ 3. Additional Terms and Conditions
The dimensions are in mm. In Germany, according to the
German law on units in measuring technology, data in inches
apply only to devices for export.
Illustrations are not binding.
Insofar as there are no remarks on the individual pages of this
catalog – especially with regard to data, dimensions and weights
given – these are subject to change without prior notice.
■ 4. Export regulations
We shall not be obligated to fulfill any agreement if such
fulfillment is prevented by any impediments arising out of
national or international foreign trade or customs requirements
or any embargoes and/or other sanctions.
Export of goods listed in this catalog may be subject to licensing
requirements. We will indicate in the delivery details whether
licenses are required under German, European and US export
lists. Goods labeled with "AL" not equal to "N" are subject to
European or German export authorization when being exported
out of the EU. Goods labeled with "ECCN" not equal to "N" are
subject to US re-export authorization.
The export indications can be viewed in advance in the
description of the respective goods on the Industry Mall, our
online catalog system. Only the export labels "AL" and "ECCN"
indicated on order confirmations, delivery notes and invoices
are authoritative.
Even without a label, or with label "AL:N" or "ECCN:N", authorization may be required i.a. due to the final disposition and
intended use of goods.
If you transfer goods (hardware and/or software and/or
technology as well as corresponding documentation, regardless
of the mode of provision) delivered by us or works and services
(including all kinds of technical support) performed by us to a
third party worldwide, you must comply with all applicable
national and international (re-)export control regulations.
If required for the purpose of conducting export control checks,
you (upon request by us) shall promptly provide us with all information pertaining to the particular end customer, final disposition and intended use of goods delivered by us respectively
works and services provided by us, as well as to any export
control restrictions existing in this relation.
The products listed in this catalog may be subject to
European/German and/or US export regulations. Any export
requiring approval is therefore subject to authorization by the
relevant authorities.
Errors excepted and subject to change without prior notice.
1)
The text of the Terms and Conditions of Siemens AGcan be
downloaded at
www.siemens.com/automation/salesmaterial-as/catalog/en/
terms_of_trade_en.pdf
© Siemens AG 2014
Catalogs
Industry Automation, Drive Technologies and Low-Voltage Power Distribution
Further information can be obtained from our branch offices
listed at www.siemens.com/automation/partner
System Solutions for Industry
Interactive Catalog on DVD
Catalog
Products for Automation and Drives, Low-Voltage Power CA 01
Distribution and Electrical Installation Technology
Building Control
GAMMA Building Control
Drive Systems
SINAMICS G130 Drive Converter Chassis Units
SINAMICS G150 Drive Converter Cabinet Units
SINAMICS GM150, SINAMICS SM150
Medium-Voltage Converters
SINAMICS PERFECT HARMONY GH180
Medium-Voltage Air-Cooled Drives
Germany Edition
SINAMICS G180
Converters – Compact Units, Cabinet Systems,
Cabinet Units Air-Cooled and Liquid-Cooled
SINAMICS S120 Chassis Format Units and
Cabinet Modules
SINAMICS S150 Converter Cabinet Units
SINAMICS DCM Converter Units
SINAMICS DCM Cabinet
SINAMICS and Motors for Single-Axis Drives
Three-Phase Induction Motors SIMOTICS HV,
SIMOTICS TN
• Series H-compact
• Series H-compact PLUS
Asynchronous Motors Standardline
Synchronous Motors with Permanent-Magnet
Technology, HT-direct
DC Motors
SIMOREG DC MASTER 6RA70 Digital Chassis
Converters
SIMOREG K 6RA22 Analog Chassis Converters
Digital: SIMOREG DC MASTER 6RM70 Digital
Converter Cabinet Units
SIMOVERT PM Modular Converter Systems
SIEMOSYN Motors
MICROMASTER 420/430/440 Inverters
MICROMASTER 411/COMBIMASTER 411
SIMOVERT MASTERDRIVES Vector Control
SIMOVERT MASTERDRIVES Motion Control
Synchronous and asynchronous servomotors for
SIMOVERT MASTERDRIVES
SIMODRIVE 611 universal and POSMO
ET G1
D 11
D 12
D 15.1
D 18.1
D 21.3
D 23.1
D 23.2
D 31
D 84.1
D 86.1
D 86.2
DA 12
DA 21.1
DA 21.2
DA 22
DA 45
DA 48
DA 51.2
DA 51.3
DA 65.10
DA 65.11
DA 65.3
DA 65.4
Note: Additional catalogs on SIMODRIVE or SINAMICS
drive systems and SIMOTICS motors with SINUMERIK
and SIMOTION can be found under Motion Control
Low-Voltage Three-Phase-Motors
SIMOTICS Low-Voltage Motors
MOTOX Geared Motors
SIMOGEAR Geared Motors
SIMOGEAR Gearboxes with adapter
D 81.1
D 87.1
MD 50.1
MD 50.11
Mechanical Driving Machines
FLENDER Standard Couplings
FLENDER High Performance Couplings
FLENDER SIG Standard industrial gear unit
FLENDER SIP Standard industrial planetary gear units
MD 10.1
MD 10.2
MD 30.1
MD 31.1
Process Instrumentation and Analytics
Field Instruments for Process Automation
Digital: SIPART Controllers and Software
Products for Weighing Technology
Digital: Process Analytical Instruments
Digital: Process Analytics,
Components for the System Integration
Digital: These catalogs are only available as a PDF
and/or as an e-book.
FI 01
MP 31
WT 10
PA 01
PA 11
Low-Voltage Power Distribution and
Electrical Installation Technology
Catalog
SENTRON · SIVACON · ALPHA
Protection, Switching, Measuring and Monitoring
Devices, Switchboards and Distribution Systems
Standards-Compliant Components for
Photovoltaic Plants
3WT Air Circuit Breakers up to 4000 A
Digital: 3VT Molded Case Circuit Breakers up to 1600 A
Digital: SIVACON System Cubicles, System Lighting
and System Air-Conditioning
Digital: ALPHA Distribution Systems
ALPHA FIX Terminal Blocks
SIVACON S4 Power Distribution Boards
Digital: SIVACON 8PS Busbar Trunking Systems
Digital: DELTA Switches and Socket Outlets
LV 10
Motion Control
SINUMERIK & SIMODRIVE
Automation Systems for Machine Tools
SINUMERIK & SINAMICS
Equipment for Machine Tools
SINUMERIK 840D sl Type 1B
Equipment for Machine Tools
SINUMERIK 808
Equipment for Machine Tools
SINUMERIK 828
Equipment for Machine Tools
SIMOTION, SINAMICS S120 & SIMOTICS
Equipment for Production Machines
Drive and Control Components for Cranes
LV 11
LV 35
LV 36
LV 50
LV 51
LV 52
LV 56
LV 70
ET D1
NC 60
NC 61
NC 62
NC 81.1
NC 82
PM 21
CR 1
Power Supply
Power supply SITOP
KT 10.1
Safety Integrated
Safety Technology for Factory Automation
SI 10
SIMATIC HMI/PC-based Automation
Human Machine Interface Systems/
PC-based Automation
ST 80/
ST PC
SIMATIC Ident
Industrial Identification Systems
ID 10
SIMATIC Industrial Automation Systems
Products for Totally Integrated Automation
SIMATIC PCS 7 Process Control System
System components
SIMATIC PCS 7 Process Control System
Technology components
Add-ons for the SIMATIC PCS 7
Process Control System
ST 70
ST PCS 7
ST PCS 7 T
ST PCS 7 AO
SIMATIC NET
Industrial Communication
IK PI
SIRIUS Industrial Controls
SIRIUS Industrial Controls
IC 10
Information and Download Center
Digital versions of the catalogs are available on the Internet at:
www.siemens.com/industry/infocenter
There you’ll find additional catalogs in other languages.
Please note the section “Downloading catalogs” on page
“Online services” in the appendix of this catalog.
© Siemens AG 2014
Industrial Security
Siemens provides products and solutions with
industrial security functions that support the
secure operation of plants, solutions, machines,
equipment and/or networks. They are important
components in a holistic industrial security
concept. With this in mind, Siemens’ products
and solutions undergo continuous development.
Siemens recommends strongly that you regularly
check for product updates.
For the secure operation of Siemens products
and solutions, it is necessary to take suitable
preventive action (e.g. cell protection concept)
and integrate each component into a holistic,
state-of-the-art industrial security concept. Thirdparty products that may be in use should also be
considered. For more information about industrial
security, visit
www.siemens.com/industrialsecurity
To stay informed about product updates as they
occur, sign up for a product-specific newsletter.
For more information, visit
http://support.automation.siemens.com
Get more information
Siemens Motors:
www.siemens.com/motors
SIMOTICS FD Flexible Duty Motors:
www.siemens.com/simotics-fd
Local partners worldwide:
www.siemens.com/automation/partner
Siemens AG
Industry Sector
Drive Technologies Division
Large Drives
Postfach 4743
90025 NÜRNBERG
GERMANY
www.siemens.com/drives
Subject to change without prior notice
Article No. E86060-K5581-A181-A2-7600
E.9115.35.LDT / Dispo 18400
KG 0514 0.6 HOF/DPG 268 En
Printed in Germany
© Siemens AG 2014
Please scan the
QR code for more
information on
Siemens Motors.
The information provided in this catalog contains merely general
descriptions or characteristics of performance which in case of actual
use do not always apply as described or which may change as a result
of further development of the products. An obligation to provide the
respective characteristics shall only exist if expressly agreed in the
terms of contract. Availability and technical specifications are subject
to change without notice.
All product designations may be trademarks or product names of
Siemens AG or supplier companies whose use by third parties for their
own purposes could violate the rights of the owners.
Token fee: 5.00 €