SINAMICS Drives SINAMICS G150 NEMA Type C enclosed chassis 150 – 800 HP Introduction This specification sheet provides a short overview of the most important characteristics of the NEMA version of SINAMICS G150 type C. For more comprehensive information about the drive and options, as well as more detailed technical data, refer to the SINAMICS G150 NEMA catalog D11.7. The SINAMICS G150 type C enclosed chassis is a standalone variable speed enclosed drive ideal for all applications that involve moving, conveying, pumping or compressing solids, liquids or gases. In particular, this includes variable torque applications such as pumps, fans, blowers, and compressors, as well as constant torque applications such as mixers, extruders and mills that do not require regeneration. This compact and quiet drive uses IGBT power semi-conductors and an innovative cooling concept. The control can be operated in either Volts/Hertz, sensorless vector or closed loop vector (with speed feedback encoder) control modes. Standard features The G150 type C enclosed chassis is a drive in a very compact enclosure, for use with external disconnect and circuit protection (for example in an existing MCC). It is offered with a limited range of standard options, such as enclosure type, input line reactor or speed encoder feedback module. SINAMICS G150 type C is delivered with the following standard features: • Basic NEMA 1 enclosure • Controller CU320-2 DP with integral PROFIBUS DP communications port and Ethernet programming port • Input/output module TM31, with digital and analog I/O • Advanced Operator Panel AOP30 for easy start-up and operation • Windows-based start-up STARTER software – common to all models of the SINAMICS drives family • CE mark June 2014 www.usa.siemens.com/drives Product Specifications Light Overload High Overload Output (at 460V (at 400V or 575V, or 500V, 60 Hz 50Hz) HP kWA Base load current IH 1 A Rated Rated Output input current current 2 IN 1 A Order No. 125 90 150110 200132 250160 350200 400250 500315 600400 700450 178 233 277 340 438 460 570 700 860 210 229 260 284 310 338 380 395 490 509 605 629 745 775 840 873 9851024 6SL3710-1GE32-1CU3 6SL3710-1GE32-6CU3 6SL3710-1GE33-1CU3 6SL3710-1GE33-8CU3 6SL3710-1GE35-0CU3 6SL3710-1GE36-1CU3 6SL3710-1GE37-5CU3 6SL3710-1GE38-4CU3 6SL3710-1GE41-0CU3 150 90 200 110 250132 300 160 350200 450250 500315 600450 700500 157 192 233 280 367 416 514 657 724 175 215 260 330 410 465 575 735 810 6SL3710-1GF31-8CU3 6SL3710-1GF32-2CU3 6SL3710-1GF32-6CU3 6SL3710-1GF33-3CU3 6SL3710-1GF34-1CU3 6SL3710-1GF34-7CU3 6SL3710-1GF35-8CU3 6SL3710-1GF37-4CU3 6SL3710-1GF38-1CU3 Output Base 460V, (at 400V load or 575V, or 500V current 60 Hz) 50Hz) I L 1 HP kW A Supply voltage 380 V to 480 V 3 ph. AC 150 200 250 300 400 500 600 700 800 110 132 160 200 250 315 400 450 560 205 250 302 370 477 590 725 820 960 SINAMICS G150 NEMA Type C Enclosed Chassis Supply voltage 500 V to 600 V 3 ph. AC 150 200 250 300 400 450 600 700 800 110 132 160 200 250 315 400 500 560 171 208 250 320 400 452 560 710 790 191 224 270 343 426 483 598 764 842 For a NEMA 12 (ventilated) enclosure (option M54), current values must be reduced to 95% of the values in this table. The input current is based on the rated output current. Note: HP ratings are based on rated current, and provided as a guide only, for standard 2, 4 or 6 pole motors. Select drive based on motor FLA and overloads. 1 2 Options Option Code Description Enclosure Options Option Code Description M06 M07 M23 M43 M54 M90 Y09 L55 U90 U91 Base (plinth) 4” (100mm) Base (plinth) 8” (200mm) Enclosure NEMA 1 filtered Enclosure IP43 Enclosure NEMA 12 (ventilated) [Requires current derate to 95%] Lifting beam/eye bolts [Recommended: Required to lift the drive off pallet] Special enclosure paint color (specify color) Power Options L23 Input line reactor Control Options G20 G33 G51 K01* K50 K95 CBC10 communication board CANopen CBE20 for SINAMICS link or PROFINET or EtherNet/IP TM150 Terminal Module for RTD monitoring Safety license (for 1 axis) SMC30 sensor module for speed feedback Control unit CU320-2 PN (PROFINET) Miscellaneous Options Enclosure space heater UL listing per UL508A cUL listing per UL508A [Requires M23, M43 or M54] [Requires M23, M43 or M54 & T58] Documentation and Languages D02 D04 D14 D58 T58 Customer drawings in dxf format Customer documentation in paper format, one set Advance copy of customer documentation (pdf) Documentation English/French Nameplate English/French For additional languages, please consult factory Testing F03 F71 F75 F77 F97 Visual inspection by customer Witnessed function test without motor Witnessed function test with test-bay motor, no load Witnessed test incl. high-voltage and isulation test Witnessed customer specific test (on request) * Integrated Safety functionality on SINAMICS G150 type C: • Basic and extended safety functions can be controlled only using PROFISAFE on PROFIBUS or PROFINET bus communications (fail safe inputs or outputs are not available) • Only encoderless implementation of safety functions is possible, with associated restrictions (only with induction motors, no optimized pulse patterns, no sweep frequency generation, no fine adjustment of pulse frequency, and only for applications with low dynamic requirements i.e. acceleration or deceleration ramp time >1 second) Design Data Spacing to ceiling if rear is mo un ted against wall 10 ” / 250 mm AIR OUT SINAMICS 79” / 2000 mm 94.5” / 2400 mm Tophat AIR IN 4” / 100 mm Option M06 Option M07 8” / 200 mm 23.6” / 600 mm WN SIDE VIEW FRONT VIEW G150 type C with transport eye bolts (tophat removed) Note: •The drawing shows the SINAMICS G150 type C enclosed chassis with louvers (option M23, M43 or M54). • For transport reasons, the tophat is delivered separately and must be fitted on site. • To assure proper air circulation through the drive, please allow a minimum space of 10” (250mm) between drive tophat and ceiling when mounted against a wall. • All dimensions are nominal for sheet steel enclosure, tolerance 0.5” (12 mm), excluding protruding components. Please refer to order drawings for exact details. SINAMICS G150 NEMA Type C Enclosed chassis Output Noise Cooling Heat Weight approx. Nominal Width (Light level LpA air flow loss (standard enclosure) Drive Enclosure Overload) (1m) at demand w/o options) WN (at 460V, or 50/60 Hz 575, 60 Hz) HP dB(A) cfm kW lb kg inch inch Model No. Supply voltage 380 V to 480 V 3 ph. AC 6SL3710-1GE32-1CU3 150 6SL3710-1GE32-6CU3 200 6SL3710-1GE33-1CU3 250 6SL3710-1GE33-8CU3 300 6SL3710-1GE35-0CU3 400 6SL3710-1GE36-1CU3 500 6SL3710-1GE37-5CU3 600 6SL3710-1GE38-4CU3 700 6SL3710-1GE41-0CU3 800 Supply voltage 500 V to 600 V 3 ph. AC 6SL3710-1GF31-8CU3 150 6SL3710-1GF32-2CU3 200 6SL3710-1GF32-6CU3 250 6SL3710-1GF33-3CU3 300 6SL3710-1GF34-1CU3 400 6SL3710-1GF34-7CU3 450 6SL3710-1GF35-8CU3 600 6SL3710-1GF37-4CU3 700 6SL3710-1GF38-1CU3 800 67 / 68 360 2.9 480 220 69 / 73 487 3.8 480 220 69 / 73 763 4.4 640 290 69 / 73 763 5.3 640 290 69 / 73 763 6.4 640 290 70 / 731653 8.2 1400 640 70 / 731653 9.6 1400 640 70 / 73 1653 10.1 1400 640 72 / 75 3136 14.4 22501020 15.8 400 15.8 400 15.8 400 15.8 400 15.8 400 23.6 600 23.6 600 23.6 600 39.41000 69 / 73 763 3.8 640 290 69 / 73 763 4.2 640 290 69 / 73 763 5.0 640 290 69 / 73 763 6.1 640 290 72 / 751653 8.11400 640 72 / 751653 7.81400 640 72 / 751653 8.71400 640 72 / 75 3136 12.72150 980 72 / 75 3136 14.122501020 15.8 400 15.8 400 15.8 400 15.8 400 23.6 600 23.6 600 23.6 600 39.4 1000 39.4 1000 Technical Data Electrical data Supply voltages and output ranges Supply systems Line frequency Output frequency Power factor fundamental / total Converter efficiency Short circuit current rating Control method Fixed speeds Skipped frequency ranges Mechanical data Type of enclosure Type of cooling Noise level LpA (1 m) Environmental protection Compliance with standards UL listing Ambient conditions Ambient temperature Relative humidity (non-condensing) Installation altitude 380 V to 480 V 3 ph AC, ±10% (-15% < 1 min) 150 to 800 HP 500 V to 600 V 3 ph AC, ±10% (-15% < 1 min) 150 to 800 HP Grounded (TN/TT) supplies or ungrounded (IT) supplies 47 Hz to 63 Hz 0 Hz to 300 Hz > 0.98 / 0.93 to 0.96 > 98% SCCR per UL508A at 480V 65kA, at 600V 35kA, when used with recognized AC input line fuses as specified in the user manual and listed circuit breakers Vector control (sensorless and closed loop) or V/Hz control 15 fixed speeds plus 1 minimum speed, programmable (in the default setting 3 fixed setpoints plus 1 minimum speed can be selected via digital inputs/ PROFIBUS) 4, programmable NEMA1 (optionally NEMA 1 filtered or NEMA12 ventilated) Color RAL 7035 light grey Forced air ventilation < 75 dB at 60 Hz line frequency Nickel plated busbars, varnish coated electronic boards Optional listing per UL508A Operation Storage Transport 32°F to 104°F (0 °C to +40 °C) -13°F (-25 °C) to 131°F (+55 °C) -13°F (-25 °C) to 158°F (+70 °C) Up to +122°F/+50°C with derating Above -40°F (-40 °C) for 24 hours 5% to 95% 5% to 95% 5% to 95% at 40 °C corresponds to 3K3 to IEC 60721-3-3 corresponds to 1K4 to IEC 60721-3-1 corresponds to 2K3 to IEC 60721-3-2 Up to 6,600 ft (2000 m) above sea level without reduction in performance, > 6,600 ft see derating data Engineering Information Overload ratings The SINAMICS G150 drive may be operated with both variable torque and constant torque loads at either light or high overload duties. The criterion for overload is that the drive is operated with its base load current before and after the overload occurs. Light overload duty is based on 110% base load current for 60 sec or 150% for 10 sec, repeated every 300 sec. Motor and drive sizing Service Factor must be considered for motors operating at Service Factors beyond 1.0. Please consult factory for assistance sizing the drive. For motors with ratings larger than the drive, please consult factory as nuisance tripping may occur if drive is not properly sized. In sensorless vector control, the rated motor current (FLA) must be at least Z⁄v of the rated drive output current. With lower motor currents, operation is possible in Volts/Hz control mode only. Advanced operator panel (AOP30) Light overload High overload duty is based on 150% base load current for 60 sec or 160% for 10 sec, repeated every 300 sec. Siemens Industry, Inc. Drive Technologies 3333 Old Milton Parkway Alpharetta, GA 30005 1-800-241-4453 [email protected] www.usa.siemens.com/drives Subject to change without prior notice. Order No. DRBR-G150C-0614 Printed in USA ©2014 Siemens Industry, Inc. The easy-to-use advanced operator panel is common to all SINAMICS enclosed drives. The AOP30 is mounted in the enclosure door of the G150 drive, and is used for start-up/commissioning or operation and troubleshooting of the drive. During the first start-up of the drive, the user will automatically be guided through the initial start-up procedure that allows a very simple and quick commissioning process. Parameters are arranged according to function groups which makes it easy to find and select them. The AOP30 features a graphical LCD with backlighting for plain text and bar graph display of process variables: • LEDs for display of operational status • Numeric keypad and drive specific hard and soft function keys • Access control to inhibit changing of parameters • Help functions with description of causes and remedies for faults and alarms • Alarm and fault status in plain text • Configurable operating display allows up to 3 variables displayed in bar graph format, with associated numerical values The information provided in this brochure contains merely general descriptions or characteristics of performance which in case of actual use do not always apply as described or which may change as a result of further development of the products. An obligation to provide the respective characteristics shall only exist if expressly agreed in the terms of contract. All product designations may be trademarks or product names of Siemens AG or supplier companies whose use by third parties for their own purposes could violate the rights of the owners.