TechnicalInformation 2PS06017E32G28213 PrimeSTACK™ Preliminarydata Keydata 1x325AACat690VAC,forcedair(fannotimplemented) Generalinformation Stacksforvariousinverterapplication.Semiconductors,heatsinks,driversandsensorsincluded. Theseareonlytechnicaldata Pleasereadcarefullythecompletedocumentationandmaintaintheproperdesignenvironment EspeciallynotetheEMCenvironmentandthecontroller'sfunctionality. Topology 1/2 B2I Application / Modulation Inverter / Sine Load type resistive, inductive Cooling forced air (fan not implemented) Market common industrial, drives, power supply Implemented sensors current, temperature Semicond. (Unit 1) none DC Link none Semicond. (Unit 2) IGBT 2x FF300R17KE3 Driver signals IGBT electrical CMOS Standards EN50178, UL94, prepared for UL508C Internal ID 28213 Mechanical drawing number 38000028 Electrical drawing number 2PS-C2-V preparedby:OW dateofpublication:2013-05-03 approvedby:AR revision:2.0 1 TechnicalInformation PrimeSTACK™ 2PS06017E32G28213 Preliminarydata Notes Overvoltage shutdown: It must be realized by the customer. Overvoltage and Overcurrent shutdown reaction time: This parameter refers to the customers controller. Electricaldata DCLink min typ max units 1100 1200 V min typ max units 690 VRMS IUnit2 325 ARMS 231 ARMS IUnit2 354 ARMS IUnit2 DC 162,0 VDC Voltage VUnit2 Continuous current VUnit2 = 690VRMS, VDC = 1100V, Tinlet = 40°C, TJ ≤ 125°C, fUnit2 = 50Hz, fsw2 = 2000Hz, cos(phi) = 0,85 Continuous current overload cap. Tinlet = 40°C, for overload capability 150% for 60s Short time current Tinlet = 40°C, 10s, every 180s, initial load = 283ARMS DC current no rotating field, Tinlet = 40°C Overcurrent shutdown within 15µs Switching frequency Power losses VUnit2 = 690V, VDC = 1100V, Tinlet = 40°C, TJ ≤ 125°C, fUnit2 = 50Hz, fsw2 = 2000Hz, cos(phi) = 0,85, IUnit2 = 325ARMS Power factor Voltage Unit2AC EMC test according to IEC61800-3 at named interfaces Apeak fsw2 20000 Hz Ploss2 3770 W cos(phi)Unit2 -1,00 1,00 min typ max units 40 W Generaldata Power losses (PCB) Aav 930 Ploss aux VBurst 2 kV control VBurst 1 kV aux (24V) VSurge 1 kV power Insulation management is designed for VLine Insulation test voltage according to EN50178, f = 50Hz, t = 60s Visol Auxiliary voltage Vaux Auxiliary power requirement Vaux = 24Vav Paux Driver and interface board see separate technical information Controllerinterfacedata Driver core Digital input level resistor to GND 10,0kΩ, capacitor to GND 1nF, high = on, min 15mA Digital output level open collector, low = ok, max 15mA Analog current outputs Unit 2 load max 1mA; at 325A Analog temperature output Overcurrent shutdown reaction time preparedby:OW dateofpublication:2013-05-03 approvedby:AR revision:2.0 Vin 690 VRMS kVRMS 2,5 min typ max 18 24 30 units Vav 40 DR240 EiceDRIVER 2ED300C17-S 0,0 W 15,0 V Vout 0,0 30,0 V Vana out 3,43 3,50 3,60 V load max 1mA; at TNTC = 77°C correspond to Tj = 125°C VT out 8,90 9,10 9,30 V afterovercurrentmessagebyPrimeSTACK™interface 10 µs 2 TechnicalInformation PrimeSTACK™ 2PS06017E32G28213 Preliminarydata Heatsinkaircooled/Thermaldata Airflow min Air pressure drop TAir = 20°C, Pair = 1013hPa, dry- and dust free, measured on side of heat sink. according to DIN 41882 Cooling air inlet temperature heat sink temperature > -25°C ∆V/∆tAir typ max units 500 ∆pAir m³/h 110 Tinlet -25 Environmentalconditions Pa 40 °C min typ max units Storage temperature Tstor -40 85 °C Ambient temperature Tamb -25 55 °C Operating temperature see chapter Heat sink air cooled / Thermal data Cooling air velocity (PCB) VAir PCB 0,3 m/s Air pressure standard atmosphere Humidity no condensation Installation height Vibration pAir 900 1100 hPa Rel. F 5 85 % 0 1000 m according to IEC60721 5 m/s² Shock according to IEC60721 40 Protection degree Pollution degree Torque at DC Terminals MDC 6,0 Torque at AC Terminals MAC Dimensions width × depth × height Weight with heat sink approximation Weight without heat sink approximation preparedby:OW dateofpublication:2013-05-03 approvedby:AR revision:2.0 3 m/s² IP00 2 10,0 16,0 20,0 Nm 216 200 167 mm 6,3 kg 1,9 kg Nm TechnicalInformation 2PS06017E32G28213 PrimeSTACK™ Preliminarydata fo - derating curve IGBT (motor) cos(phi) = 0,85 Tcool medium = 40°C fsw - derating curve IGBT (motor) cos(phi) = 0,85 Tcool medium = 40°C 130 140 120 130 110 120 100 110 100 90 90 I/Inorm [%] I/Inorm [%] 80 70 60 50 70 60 50 40 40 30 30 20 20 10 10 0 -5 0 5 0 10 15 20 25 30 35 40 45 50 55 f0 [Hz] 0.20 0.18 i: 1 2 3 4 ri[K/W]: 0.03136 0.08562 0.03032 0.02254 τi[s]: 2.869 41.23 145.58 145.58 0.16 0.14 0.12 0.10 0.08 0.06 0.04 0.02 0.00 0.1 1 10 0 1000 2000 3000 4000 fsw [Hz] Transient thermal impedance per switch Tcool medium = 40°C Zth heat sink to ambient [K/W] 80 100 1000 time [s] preparedby:OW dateofpublication:2013-05-03 approvedby:AR revision:2.0 4 5000 6000 7000 TechnicalInformation PrimeSTACK™ 2PS06017E32G28213 Preliminarydata Mechanicaldrawing preparedby:OW dateofpublication:2013-05-03 approvedby:AR revision:2.0 5 TechnicalInformation PrimeSTACK™ 2PS06017E32G28213 Preliminarydata Circuitdiagram + Input VCE(sat) / supply 2 Error Output TOP A BOT - Digital circuit Error messages 15 IGBT TOP EiceDRIVER™ 14 IGBT BOT + B - 3 Temp. error J 22 Voltage error Error messages 13 GND digital 25 GND digital 4 13V÷30V 6 GND 18 GND 5 15V/50mA Out 17 15V/50mA Power supply In 16 13V÷30V e ltag rvo de Un PTC Option DC link capacitors + 20 Current Analog circuit Output 19 Temperature 21 Voltage DC-Link Mana 7 GND analog 8 GND analog 9 GND analog A HB ent urr BB erc H v t O en urr erc Ov - High voltage area in grey e tag ut s utp p. o m e CB ert Ov p. P em ert k Ov -Lin DC ge olta erv v O Option V Voltage measurement safety separation between high voltage area and low voltage area 10 NC Error Table 11 NC Error outputs (open collector) Error Driver Core Overcurrent Overtemperature output stage Overtemperature PCB Overvoltage DC-Link (Option) Undervoltage power supply X= high level with required external 23 NC 24 NC SUB-D-Connector 25pole male 1 True earth/shield 1 female thread UNC4/40 front view preparedby:OW dateofpublication:2013-05-03 approvedby:AR revision:2.0 X X X Temp. Pin 3 Voltage Pin 22 X X X X X pull up resistor. For detailed technical information please refer the PrimeSTACK manual. 6 2PS-C2-V-Rev03 Error Pin 2 12 NC TechnicalInformation PrimeSTACK™ 2PS06017E32G28213 Preliminarydata Terms&Conditionsofusage Thedatacontainedinthisproductdatasheetisexclusivelyintendedfortechnicallytrainedstaff.Youandyourtechnical departmentswillhavetoevaluatethesuitabilityoftheproductfortheintendedapplicationandthecompletenessoftheproduct datawithrespecttosuchapplication. Thisproductdatasheetisdescribingthecharacteristicsofthisproductforwhichawarrantyisgranted.Anysuchwarrantyis grantedexclusivelypursuantthetermsandconditionsofthesupplyagreement.Therewillbenoguaranteeofanykindforthe productanditscharacteristics. Shouldyourequireproductinformationinexcessofthedatagiveninthisproductdatasheetorwhichconcernsthespecific applicationofourproduct,pleasecontactthesalesoffice,whichisresponsibleforyou(seewww.infineon.com,sales&contact). Forthosethatarespecificallyinterestedwemayprovideapplicationnotes. Duetotechnicalrequirementsourproductmaycontaindangeroussubstances.Forinformationonthetypesinquestionplease contactthesalesoffice,whichisresponsibleforyou. ShouldyouintendtousetheProductinaviationapplications,inhealthorliveendangeringorlifesupportapplications,please notify.Pleasenote,thatforanysuchapplicationsweurgentlyrecommend -toperformjointRiskandQualityAssessments; -theconclusionofQualityAgreements; -toestablishjointmeasuresofanongoingproductsurvey, andthatwemaymakedeliverydependedontherealization ofanysuchmeasures. Ifandtotheextentnecessary,pleaseforwardequivalentnoticestoyourcustomers. Changesofthisproductdatasheetarereserved. SafetyInstructions Priortoinstallationandoperation,allsafetynoticesandwarningsandallwarningsignsattachedtotheequipmenthavetobe carefullyread.Makesurethatallwarningsignsremaininalegibleconditionandthatmissingordamagedsignsarereplaced.To installationandoperation,allsafetynoticesandwarningsandallwarningsignsattachedtotheequipmenthavetobecarefully read.Makesurethatallwarningsignsremaininalegibleconditionandthatmissingordamagedsignsarereplaced. preparedby:OW dateofpublication:2013-05-03 approvedby:AR revision:2.0 7