LR 200 Catalog Sheet

© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200
■ Overview
■ Configuration
Installation
Min. 300 mm (1 ft) for every
3 m (10 ft) of vessel wall.
Note:
• Beam angle is the width of the
cone where the energy density
is half of the peak energy
density.
• Beam angle for horn antenna
dependent on horn size
• The peak energy density is
directly in front of and in line
with the rod antenna.
• There is a signal transmitted
outside of the beam angle;
therefore false targets may be
detected.
SITRANS LR200 is a 2-wire, 6 GHz pulse radar level transmitter
for continuous monitoring of liquids and slurries in process vessels including high temperature, pressure, agitation, and
turbulence to a range of 20 m (65 ft).
Beam angle
Rod: 28°
4" horn: 29°
6" horn: 20°
8" horn: 17°
4
Mounting unit on vessel
■ Benefits
■ Application
SITRANS LR200’s unique design allows safe and simple programming using the Intrinsically Safe handheld programmer
without having to open the instrument’s lid. It also features a
built-in alphanumeric display in four languages.
Conical
Flat
Parabolic
Mounting unit on stilling well
Mounting on a nozzle
Orient front or
back of device
toward stillpipe
slots.
Min. 10 (0.4)
• Graphical local user interface (LUI) makes operation simple
with plug-and-play setup using the intuitive Quick Start Wizard
• LUI displays echo profiles for diagnostic support
• Communication using HART or PROFIBUS PA
• Process Intelligence signal processing for improved
measurement reliability and Auto False-Echo Suppression of
fixed obstructions
• Programming using infrared Intrinsically Safe handheld
programmer or SIMATIC PDM
The SITRANS LR200 has a standard Uni-Construction polypropylene rod antenna that offers excellent chemical resistance and
is hermetically sealed. The Uni-Construction antenna features
an internal, integrated shield that eliminates vessel nozzle interference.
Startup is easy with as few as two parameters for basic operation. Installation is simplified as the electronics are mounted on
a rotating head that swivels, allowing the instrument to line up
with conduit or wiring connections or simply to adjust the position for easy viewing. SITRANS LR200 features Process Intelligence signal-processing technology for superior reliability.
• Key Applications: liquid process vessels with agitators,
vaporous liquids, high temperatures, asphalt, digesters
SITRANS LR200 installation, dimensions in mm (inch)
Siemens FI 01 · 2016
4/201
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200
■ Technical specifications
Power supply
Mode of operation
Measuring principle
Radar level measurement
Frequency
5.8 GHz (North America 6.3 GHz)
Measuring range
0.3 ... 20 m (1.0 ... 65 ft)
Output
PROFIBUS PA
Nominal 24 V DC (max. 30 V DC)
with max. 550 
Nominal 24 V DC (max. 30 V DC)
with max. 250 
• 10.5 mA
• Per IEC 61158-2
Analog output
4 ... 20 mA
Accuracy
± 0.02 mA
Span
Proportional or inversely proportional
General
CSAUS/C, CE, FM, RCM
Communications
HART
Marine
• Lloyd’s Register of Shipping
• ABS Type Approval
Radio
FCC, Industry Canada, and European
(R&TTE), RCM
Optional: PROFIBUS PA (Profile 3.0,
Class B)
Programmable as high, low or hold
(Loss of Echo)
Fail-safe
4
4 ... 20 mA/HART
• General Purpose, Non-incendive,
Intrinsically Safe
• Flame proof, Increased safety,
Explosion proof
Performance (according to reference conditions IEC60770-1)
From end of antenna to 600 mm
40 mm (1.57 inch)
Remainder of range
10 mm (0.4 inch) or 0.1 % of span
(whichever is greater)
Certificates and approvals
Hazardous
• Intrinsically Safe (Brazil)
• Explosion Proof (Canada/USA)
• Intrinsically Safe (Canada/USA)
Rated operating conditions
• Non-incendive (USA)
Installation conditions
• Location
Indoor/outdoor
Ambient conditions (enclosure)
• Ambient temperature
• Installation category
• Pollution degree
-40 ... +80 °C (-40 ... +176 °F)
I
4
Medium conditions
Dielectric constant r
Vessel temperature and pressure
r > 1.6 (for r < 3, use stillpipe)
Varies with connection type; see
Pressure/Temperature curves for
more information
Design
Enclosure
• Material
• Cable inlet
Aluminum, polyester powder coated
2 x M20 x 1.5 or 2 x ½" NPT
Degree of protection
Type 4X/NEMA 4X, Type 6/ NEMA 6,
IP67, IP68
Weight
< 2.82 kg (6.21 lb) (polypropylene
rod antenna)
Display (local)
Multi-segment alphanumeric liquid
crystal with bar graph (representing
level) available in four languages
Antenna
• Material
• Dimensions
• Optional rods and horn
Process connections
• Process connection
Polypropylene rod, hermetically
sealed construction, optional PTFE
Standard 100 mm (4 inch) shield for
maximum 100 mm (4 inch) nozzle, or
optional 250 mm (10 inch) long shield
Refer to SITRANS LR200 Antennas
for optional rods and horns
1½" NPT [(Taper), ANSI/ASME
B1.20.1]
R 1½" [(BSPT), EN 10226],
or
• Flange connection
4/202
Siemens FI 01 · 2016
G 1½" [(BSPP), EN ISO 228-1]
(polypropylene rod antenna)
Refer to SITRANS LR200 Antennas
for more connections
• Flame Proof/Increased Safety
(China)
• Flame Proof (Europe)
• Increased Safety (Europe)
• Intrinsically Safe (Europe)
• Intrinsically Safe (International)
• Intrinsically Safe
(Russia/Kazakhstan)
INMETRO Ex ia IIC T4 Ga
CSA/FM, Class I, Div. 1, Groups A, B,
C, D; Class II, Div. 1, Groups E, F, G;
Class III, T4
CSA/FM, Class I, Div. 1, Groups A, B,
C, D; Class II, Div. 1, Groups E, F, G;
Class III, T4
FM, Class I, Div. 2, Groups A, B, C, D,
T5
NEPSI Ex d mb ia IIC T4/ Ex e mb ia
IIC T4
ATEX II 1/2 G Ex d mb ia IIC T4 Ga/
Gb
ATEX II 1/2 G Ex e mb ia IIC T4 Ga/
Gb
ATEX II 1G Ex ia IIC T4
IECEx Ex ia IIC T4
EAC Ex ia
Programming
Intrinsically Safe Siemens handheld
Infrared receiver
programmer
• Approvals for handheld programmer IS model:
ATEX II 1GD Ex ia IIC T4 Ga
Ex iaD 20 T135 °C Ta = -20 ... +50 °C
CSA/FM Class I, II, and III, Div. 1,
Groups A, B, C, D, E, F, G, T6
Ta = +50 °C
Handheld communicator
HART communicator 375
PC
• SIMATIC PDM
• AMS
• SITRANS DTM (for connecting to
FDT such as PACTware or Fieldcare)
Display (local)
Multi-segment alphanumeric liquid
crystal with bar graph (representing
level) available in four languages
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LR200, Uni-Construction
polypropylene rod antenna version
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
process vessels including high temperature and
pressure, to a range of 20 m (66 ft).
Max. 3 bar g (43.5 psi g) pressure and
80 °C (176 °F)
7ML5422-
Further designs
7777 0
Please add "-Z" to Article No. and specify Order
code(s).
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Enclosure/Cable inlet
Aluminum, epoxy painted
2 x ½" NPT
2 x M20 x 1.5
Polypropylene antenna type (Max. 3 Bar pressure and 80 °C)
1½" NPT [(Taper), ANSI/ASME B1.20.1],
c/w integral 100 mm shield
R 1½" [(BSPT), EN 10226],
c/w integral 100 mm shield
G 1½" [(BSPP), EN ISO 228-1],
c/w integral 100 mm shield
1½" NPT [(Taper), ANSI/ASME B1.20.1],
c/w integral 250 mm shield
R 1½" [(BSPT), EN 10226],
c/w integral 250 mm shield
G 1½" [(BSPP), EN ISO 228-1],
c/w integral 250 mm shield
Approvals
General Purpose, CE, R&TTE, RCM
General Purpose, CSA, FM, Industry Canada, FCC
Intrinsically Safe, CSA Class I, II, Div. 1, Groups A,
B, C, D, E, F, G, Industry Canada
Intrinsically Safe, FM Class I, II, Div. 1, Groups A,
B, C, D, E, F, G, FCC
Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T4,
INMETRO Ex ia IIC T4, CE, R&TTE, RCM; EAC
Non incendive, FM Class I, Div. 2, Groups A, B, C,
D, FCC1)
Increased Safety, ATEX II 1/2G Ex e mb ia IIC T4
Ga/Gb, CE, R&TTE, RCM; EAC2)3)
Flame Proof, ATEX II 1/2G Ex d mb ia IIC T4 Ga/
Gb, CE, R&TTE, RCM; EAC3)
Explosion Proof, CSA/FM Class I, II, III, Groups A,
B, C, D, E, F, G, Industry Canada, FCC1)3)
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, start-up at < 3.6 mA
1)
Available with enclosure option 2 only
Available with enclosure option 3 only
3)
Available with communication option 3 only
2)
2
3
Order code
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Namur NE43 compliant, device preset to failsafe
< 3.6 mA1)
N07
Operating Instructions for HART/mA device
Article No.
English
A5E32337676
German
A5E34942758
Note: The Operating Instructions should be
ordered as a separate item on the order.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
A
B
C
4
This device is shipped with the Siemens Level and
Weighing manual DVD containing the ATEX Quick
Start and Operating Instructions library.
D
E
Operating Instructions for PROFIBUS PA device
F
English
A5E32337680
German
A5E34942820
Note: The Operating Instructions should be
ordered as a separate item on the order.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
A
B
C
D
This device is shipped with the Siemens Level and
Weighing manual DVD containing the ATEX Quick
Start and Operating Instructions library.
E
F
Accessories
G
Handheld programmer, Intrinsically safe, EEx ia
7ML1930-1BK
H
HART modem/USB
(for use with a PC and SIMATIC PDM)
7MF4997-1DB
J
One metallic cable gland M20 x 1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART2)
7ML1930-1AP
2
3
One metallic cable gland M20 x 1.5,
7ML1930-1AQ
rated -40 ... +80 °C (-40 ... +176 °F), PROFIBUS PA2)
One general purpose polymeric cable gland
M20 x 1.5, rated -20 ... + 80 °C (-40 ... +176 °F)
7ML1930-1AM
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
1)
Available with communication option 3 only
2)
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
Siemens FI 01 · 2016
4/203
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LR200, Flange Adapter/PTFE Rod
Antenna Version
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
process vessels including high temperature and
pressure, to a range of 20 m (66 ft).
7ML5423-
SITRANS LR200, Flange Adapter/PTFE Rod
Antenna Version
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
process vessels including high temperature and
pressure, to a range of 20 m (66 ft).
7ML5423-
7 7 7 77 - 77 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Antenna material (uses antenna adapter)
PTFE, uses antenna adapter and
additional process connection below
4
Enclosure/Cable inlet
Aluminum, Epoxy painted
2 x ½" NPT
2 x M20 x 1.5
1
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, start-up at < 3.6 mA
Process connection (refer to Pressure/
Temperature curves, page 4/211)
Flanges (316L stainless steel)
DN 50 PN 16, Type A, flat faced
DN 80 PN 16, Type A, flat faced
DN 100 PN 16, Type A, flat faced
DN 150 PN 16, Type A, flat faced
AA
BA
CA
DA
2" ASME 150 lb, flat faced
3" ASME 150 lb, flat faced
4" ASME 150 lb, flat faced
6" ASME 150 lb, flat faced
FB
GB
HB
JB
DN 50 PN 40, flat faced
DN 80 PN 40, flat faced
DN 100 PN 40, flat faced
DN 150 PN 40, flat faced
AC
BC
CC
DC
2" ASME 300 lb, flat faced, available with
Pressure rating option 1 only due to flange hole
spacing
3" ASME 300 lb, flat faced
4" ASME 300 lb, flat faced
6" ASME 300 lb, flat faced
FD
JIS DN 50 10K
JIS DN 80 10K
JIS DN 100 10K
JIS DN 150 10K
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5, or EN 1092-1, or JIS B 2220 standard.)
GD
HD
JD
LA
MA
LC
R 2" [(BSPT), EN 10226]
G 1½" [(BSPP), EN ISO 228-1]
G 2" [(BSPP), EN ISO 228-1]
MC
LE
ME
0
1
2
100 mm (4 inch) extension,
316L stainless steel shield1)
150 mm (6 inch) extension,
316L stainless steel shield1)
200 mm (8 inch) extension,
316L stainless steel shield1)
3
250 mm (10 inch) extension,
316L stainless steel shield1)
6
Process seal/gasket
Integral Gasket,
for flat faced flange process connections only,
not for Antenna extension options 3 ... 6
FKM O-ring,
not available for combination of flat faced flanges
with Antenna extension options 0, 1 or 2
4/204
Siemens FI 01 · 2016
4
5
0
1
2
3
B
C
A
B
C
Intrinsically Safe, FM Class I, II, Div. 1, Groups A,
B, C, D, E, F, G, FCC
Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T4,
INMETRO Ex ia IIC T4, CE, R&TTE, RCM; EAC
Non incendive, FM Class I, Div. 2, Groups A, B, C, D,
FCC2)
D
Increased Safety, ATEX II 1/2G Ex e mb ia IIC T4
Ga/Gb, CE, R&TTE, RCM; EAC 3)4)
Flame Proof, ATEX II 1/2G Ex d mb ia IIC T4 Ga/
Gb, CE, R&TTE, RCM; EAC4)
Explosion Proof, CSA/FM Class I, II, III, Groups A,
B, C, D, E, F, G, Industry Canada, FCC2)4)
G
Pressure rating
Rating per Pressure/Temperature curves in manual
0.5 bar g (7.25 psi g) maximum
AE
BE
CE
DE
Threaded connection (316L stainless steel)
1½" NPT [(Taper), ANSI/ASME B1.20.1]
2" NPT [(Taper), ANSI/ASME B1.20.1]
R 1½" [(BSPT), EN 10226]
Antenna extensions or Inactive shield length
No antenna extension
50 mm (2 inch) extension, PTFE
100 mm (4 inch) extension, PTFE
Approvals
General Purpose, CE, R&TTE, RCM
General Purpose, CSA, FM, Industry Canada, FCC
Intrinsically Safe, CSA Class I, II, Div. 1,
Groups A, B, C, D, E, F, G, Industry Canada
7 7 7 77 - 77 7 7
E
F
H
J
0
1
1)
Available with process connection options BA, CA, DA, GB, HB, JB, BC,
CC, DC, GD, HD, JD, BE, CE, DE, MA, MC, ME only
2)
Available with enclosure option 2 only
3)
Available with enclosure option 3 only
4)
Available with communication option C only
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200
Selection and Ordering data
Order code
Further designs
Please add "-Z" to Article No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y15
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
Namur NE43 compliant, device preset to failsafe
< 3.6 mA3)
N07
Operating Instructions for HART/mA device
Article No.
English
A5E32337676
German
A5E34942758
4
Note: The Operating Instructions should be
ordered as a separate item on the order.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
This device is shipped with the Siemens Level and
Weighing manual DVD containing the ATEX Quick
Start and Operating Instructions library.
Operating Instructions for PROFIBUS PA device
English
A5E32337680
German
A5E34942820
Note: The Operating Instructions should be
ordered as a separate item on the order.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
This device is shipped with the Siemens Level and
Weighing manual DVD containing the ATEX Quick
Start and Operating Instructions library.
Accessories
Handheld programmer, Intrinsically safe, EEx ia
7ML1930-1BK
Antenna, rod, PTFE
7ML1830-1HC
Antenna extension, 50 mm (2 inch), PTFE
7ML1830-1CH
Antenna extension, 100 mm (4 inch), PTFE
7ML1830-1CG
HART modem / USB
(for use with PC and SIMATIC PDM)
7MF4997-1DB
Metallic cable gland M20 x 1.5,
rated -40 °C (-40 °F) ... 80 °C (176 °F),
HART (two are required)
7ML1930-1AP
Metallic cable gland M20 x 1.5,
rated -40 °C (-40 °F) ... 80 °C (176 °F),
PROFIBUS PA (two required)
7ML1930-1AQ
One General Purpose polymeric cable gland
M20 x 1.5, rating for -20 °C (-4°F) ...+ 80 °C (176 °F)
7ML1930-1AM
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
Siemens FI 01 · 2016
4/205
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200
Selection and Ordering data
Article No.
Selection and Ordering data
Article No.
SITRANS LR200,
Flange adapter/Horn Antenna version
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
process vessels including high temperature and
pressure, to a range of 20 m (66 ft).
7ML542577 7 77 - 77 77
SITRANS LR200,
Flange adapter/Horn Antenna version
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
process vessels including high temperature and
pressure, to a range of 20 m (66 ft).
7ML54257 7 7 77 - 77 7 7
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
4
Antenna material (uses antenna adapter)
316L stainless steel with PTFE cone emitter
316L stainless steel with PTFE cone emitter and
purge connection with 1/8" NPT inlet1)
Sliding waveguide system with 1 000 mm (40 inch)
waveguide1)2)
Process connection (refer to Pressure/
Temperature curves, page 4/211)
Flanges (316L stainless steel)
DN 50 PN 16 EN 1092-1 Type A flat faced1)
DN 80 PN 16 EN 1092-1 Type A flat faced
DN 100 PN 16 EN 1092-1 Type A flat faced
DN 150 PN 16 EN 1092-1 Type A flat faced
DN 200 PN 16 EN 1092-1 Type A flat faced
DN 80 PN 10/16 DIN EN 1092-1 Type B1 raised face3)
DN 100 PN 10/16 DIN EN 1092-1 Type B1 raised face3)
DN 150 PN 10/16 DIN EN 1092-1 Type B1 raised face3)
DN 200 PN 16 DIN EN 1092-1 Type B1 raised face3)
2" ASME 150 lb, flat faced1)
3" ASME 150 lb, flat faced
4" ASME 150 lb, flat faced
6" ASME 150 lb, flat faced
8" ASME 150 lb, flat faced
DN 50 PN 40, flat faced3)
DN 80 PN 40, flat faced3)
DN 100 PN 40, flat faced3)
DN 80 PN 25/40 DIN EN 1092-1 Type B1 raised face3)
DN 100 PN 25/40 DIN EN 1092-1 Type B1 raised
face3)
DN 150 PN 25/40 DIN EN 1092-1 Type B1 raised
face3)
2" ASME 300 lb, flat faced1)3)
3" ASME 300 lb, flat faced3)
4" ASME 300 lb, flat faced3)
JIS DN 50 10K1)
JIS DN 80 10K
JIS DN 100 10K
JIS DN 150 10K
JIS DN 200 10K
(Note: Flange bolting patterns and facings
dimensionally correspond to the applicable
ASME B16.5, or EN 1092-1, or JIS B 2220 standard.)
Communication/Output
PROFIBUS PA
4 ... 20 mA, HART, start-up at < 3.6 mA
4/206
Siemens FI 01 · 2016
Process seal/gasket
FKM (-40 ... +200 °C)
Nitrile (-40 ... +60 °C),
sliding waveguide systems only
FFKM (-35 ... +200 °C)
Enclosure/Cable inlet
Aluminum, Epoxy painted
2 x ½" NPT
2 x M20 x 1.5
Horn size/Waveguide options
80 mm (3 inch) horn4)
100 mm (4 inch) horn4)
150 mm (6 inch) horn
200 mm (8 inch) horn
100 mm (4 inch) horn with 100 mm (4 inch)
waveguide extension4)
100 mm (4 inch) horn with 150 mm (6 inch)
waveguide extension4)
100 mm (4 inch) horn with 200 mm (8 inch)
wave-guide extension4)
100 mm (4 inch) horn with 250 mm (10 inch)
waveguide extension4)
150 mm (6 inch) horn with 100 mm (4 inch)
waveguide extension
150 mm (6 inch) horn with 150 mm (6 inch)
waveguide extension
150 mm (6 inch) horn with 200 mm (8 inch)
waveguide extension
0
1
2
AA
BA
CA
DA
EA
BF
CF
DF
EF
FB
GB
HB
JB
KB
AC
BC
CC
CG
DG
150 mm (6 inch) horn with 250 mm (10 inch)
waveguide extension
200 mm (8 inch) horn with 100 mm (4 inch)
waveguide extension
200 mm (8 inch) horn with 150 mm (6 inch)
waveguide extension
200 mm (8 inch) horn with 200 mm (8 inch)
waveguide extension
200 mm (8 inch) horn with 250 mm (10 inch)
waveguide extension
EG
FD
GD
HD
AE
BE
CE
DE
EE
1
2
0
1
2
2
3
B
C
D
E
F
G
H
J
K
L
M
N
P
Q
R
S
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS LR200,
Flange adapter/Horn Antenna version
2-wire, 6 GHz pulse radar level transmitter for
continuous monitoring of liquids and slurries in
process vessels including high temperature and
pressure, to a range of 20 m (66 ft).
7ML542577 7 77 - 77 77
Further designs
Approvals
General Purpose, CE, R&TTE, RCM
General Purpose, CSA, FM, Industry Canada, FCC
Intrinsically Safe, CSA Class I, II, Div. 1, Groups A,
B, C, D, E, F, G, Industry Canada
Intrinsically Safe, FM Class I, II, Div. 1, Groups A, B,
C, D, E, F, G, FCC
Intrinsically Safe, IECEx/ATEX II 1G Ex ia IIC T4,
INMETRO Ex ia IIC T4, CE, R&TTE, RCM; EAC
Non incendive, FM Class I, Div. 2, Groups A, B, C, D,
FCC5)
Increased Safety, ATEX II 1/2G Ex e mb ia IIC T4
Ga/Gb, CE, R&TTE, RCM; EAC6)7)
Flame Proof, ATEX II 1/2G Ex d mb ia IIC T4 Ga/Gb,
CE, R&TTE, RCM; EAC7)
Explosion Proof, CSA/FM Class I, II, III, Groups A,
B, C, D, E, F, G, Industry Canada, FCC5)7)
Pressure rating
Rating per Pressure/Temperature curves in manual
0.5 bar g (7.25 psi g) maximum
Order code
Please add "-Z" to Article No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:
Measuring-point number/identification
(max. 27 characters); specify in plain text
Y15
A
B
C
Manufacturer's test certificate: M to DIN 55350,
Part 18 and to ISO 9000
C11
Inspection Certificate Type 3.1 per EN 10204
C12
D
Namur NE43 compliant, device preset to failsafe
< 3.6 mA1)
N07
E
Operating Instructions for HART/mA device
Article No.
F
English
A5E32337676
German
A5E34942758
G
Note: The Operating Instructions should be
ordered as a separate item on the order.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
H
J
0
1
This device is shipped with the Siemens Level and
Weighing manual DVD containing the ATEX Quick
Start and Operating Instructions library.
1)
Available with pressure rating option 1 only
Operating Instructions for PROFIBUS PA device
2)
Maximum Process Temperature 60 °C (140 °F)
English
A5E32337680
3)
Available with Antenna Material options 0 and 1 only
4)
German
A5E34942820
For stillpipe applications only
5)
Available with enclosure option 2 only
6)
Available with enclosure option 3 only
7)
Available with communication option 2 only
Note: The Operating Instructions should be
ordered as a separate item on the order.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
This device is shipped with the Siemens Level and
Weighing manual DVD containing the ATEX Quick
Start and Operating Instructions library.
Accessories
Handheld programmer, Intrinsically safe, EEx ia
7ML1930-1BK
HART modem/USB
(for use with a PC and SIMATIC PDM)
7MF4997-1DB
One metallic cable gland M20 x 1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART2)
7ML1930-1AP
One metallic cable gland M20 x 1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
PROFIBUS PA3)
7ML1930-1AQ
One general purpose polymeric cable gland
M20 x 1.5, rated -40 ... +80 °C (-40 ... +176 °F)
7ML1930-1AM
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For applicable back up point level switch see point level measurement section
1)
Available with communication option 2 only
2)
Product shipped with plastic cable gland, rated to -20 °C.
If -40 °C rating required, then metallic cable gland is recommended.
3)
Available with enclosure option 2 only
Siemens FI 01 · 2016
4/207
4
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200
■ Dimensional drawings
SITRANS LR200 with polypropylene
shielded rod antenna
PTFE rod antenna, threaded
Threaded connection
PTFE rod, external shield
½” NPT cable entry
(or alternatively M20 x 1.5 cable gland)
Nameplate
Nameplate
Threaded cover
187 (7.4)
154
(6)
4
Reference point
AISI 316,
2” NPT,
R 2” (BSPT)
or G 2” (BSPP)
185
(7.3)
Enclosure/
electronics
158
(6.1)
Reference point
AISI 316,
17
2” NPT,
(0.67)
R 2” (BSPT)
or G 2” (BSPP)
Antenna shield
(inactive length)
AISI 316
PTFE
antenna
Locking ring
412
(16.3)
Reference point
Std. 296 (11.7) min.
Option: 446 (17.6) max.
Shield Length (S.L.):
min. 100 (4)
(customer specified)
Overall Length (L):
374 (14.7) plus
shielded length
Shield length (internal):
Standard: 100 (4)
Optional: 250 (10)
Mounting
thread
Polypropylene
rod antenna
Std. 575 (22.6) min.
Option: 725 (28.5) max.
Horn antenna with flat faced flange
Enclosure/electronics
Nameplate
187
(7.4)
Sliding waveguide
Locking ring
Reference point
Flange
Nameplate
Ø80 (3)
Horn
187
(7.4)
Reference point
200 (8)
Sliding flange
1 000
(40.8)
934
(36.8)
111
(4.40)
100 (4)
150 (6)
200 (8)
Fully inserted length =
934 mm + horn height
SITRANS LR200, dimensions in mm (inch)
4/208
Siemens FI 01 · 2016
206
(8.11)
131
(5.16)
100
(4)
150 (6)
40
(1.6)
305
(12.01)
Active antenna
(PTFE)
225.8
(8.89)
325.1
(12.79)
187
(7.4)
18
(0.7)
S.L.
L
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200
■ Schematics
Connect the wires to the
terminals as shown: the
polarity is identified on the
terminal block.
Gland
Hand programmer
Shield for HART and
PROFIBUS PA
intrinsically safe
versions only.
4
Part number:
7ML1930-1BK
Notes:
1.
2.
3.
4.
DC terminal shall be supplied from an SELV source in accordance with IEC 1010-1 Annex H.
All field wiring must have insulation suitable for rated input voltages.
Use shielded twisted pair cable (14 ... 22 AWG) for HART version.
Separate cables and conduit may be required to conform to standard instrumentation wiring practices or electrical codes.
SITRANS LR200 connections
Siemens FI 01 · 2016
4/209
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200 Antennas
■ Integration
Horn with waveguide
extension. Used for high
temperature isolation, long
standpipes, and clearing
tank obstructions.
4
Sliding waveguide antenna,
typically for digester applications
that include an isolation valve
between the instrument and the vessel.
Flat faced flange
connection with
PTFE rod antenna.
Shielded rod antenna
with a stainless steel
shield eliminates
standpipe interference.
Various lengths
available.
SITRANS LR200 with flange
adapter for connection to
optional antennas.
Antenna configurations for SITRANS LR200
■ Technical specifications
Antenna Types
Flat Faced Flange with Rod
Shielded Rod
Horn (4", 6", 8" sizes available)
Connection type
Flat faced flange
nominal pipe sizes 50, 80, 100,
150 mm (2, 3, 4, 6 inch)
Threaded 2" NPT, R 2" (BSPT),
G 2" (BSPP) or flat faced flange
nominal pipe sizes 80, 100 mm
(3, 4 inch)
Flat faced flange
nominal pipe sizes 50, 80, 100,
150 mm (2, 3, 4, 6 inch)
Wetted parts
PTFE
PTFE, 316L stainless steel, FKM O-ring 316L stainless steel
PTFE, FKM O-ring
Extensions
50 or 100 mm (2 or 4 inch) PTFE or
UHMW-PE
100, 150, 200 or 250 mm
(4, 6, 8 or 10 inch)
standard shield length
Use waveguide for extensions to
6 m (20 ft) long
Dielectric constant
>3
>3
>3
Insertion length (max.)
41 cm (16.3 inch)
Variable
Variable with extension
Purging option (liquid or gas)
No
No
Yes
Sliding waveguide option for digest- Yes
ers1)
No
Yes
Weight2)
5.0 kg (11 lb)
7.5 kg (16.5 lb)
6.5 kg (14.3 lb)
1)
Maximum pressure 0.5 bar g at 60 °C (7.25 psi g at 140 °F)
2) Not including extensions, includes SITRANS LR200 and smallest process connection
4/210
Siemens FI 01 · 2016
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200 Antennas
■ Characteristic curves
Ambient temperature (°C)
Maximum flange and process temperatures versus allowable ambient temperature
90
130 °C
80
70
67 °C
60
50
Polypropylene rod
40
PTFE rod/
horn antenna
30
20
4
10
0
0
20
40
60
80
100
120
140
160
180
200
220
Process flange surface temperature (°C)
SITRANS LR200 ambient/process flange surface temperature curve
Siemens FI 01 · 2016
4/211
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200 Antennas
PTFE rod antenna with
integral gasket 150# and PN 16 sizes
flange series 22452, 316 stainless steel, flat face
16.0
Pressure (bar, gauge)
14.0
(A)
(B)
12.0
10.0
(C)
8.0
6.0
4.0
(A) 22452 50 mm/2 inch nom.
2.0
(B) 22452 80 mm/3 inch nom.
0.0
-40 -20
4
(C) 22452 100 mm/4 inch nom.
0
20
40
60 80 100 120 140 160 180 200
Temperature (°C)
Horn antenna and/or wave guide with
PTFE emitter 150# and PN 16 sizes
flange series 22452, 316 stainless steel, flat face
16.0
(E)
Pressure (bar, gauge)
14.0
(D)
12.0
10.0
(F)
8.0
6.0
(D) 22452 80 mm/3 inch nom.
(G)
4.0
(E) 22452 100 mm/4 inch nom.
2.0
(F) 22452 150 mm/6 inch nom.
0.0
-50
(G) 22452 200 mm/8 inch nom.
0
50
100
Temperature (°C)
150
200
Threaded process
1.5" & 2" NPT, BSP, & G
40.0
Pressure (bar, gauge)
35.0
30.0
25.0
(H) 1.5" and 2", thread connection
20.0
15.0
10.0
(H)
5.0
0.0
-50
0
50
100
Temperature (°C)
150
SITRANS LR200 process pressure/temperature derating curves
4/212
Siemens FI 01 · 2016
200
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200 Specials
■ Selection and ordering data
SITRANS LR200 Specials
SITRANS LR200 Specials
Article No.
Article No.
SITRANS LR200 PROFIBUS PA Aluminum
Enclosure Kit with electronics and covers
(7ML5422, 7ML5423, 7ML5424, 7ML5425),
calibrated for use with standard rod antenna
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option E, with PROFIBUS
PA communication, no process connection.
A5E01483420
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option A, with PROFIBUS
PA communication, no process connection.
A5E01483440
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 6.3 GHz, M20
cable inlet, approval option C, with PROFIBUS
PA communication, no process connection.
A5E01483456
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 6.3 GHz, NPT
cable inlet, approval option C, with PROFIBUS
PA communication, no process connection.
A5E01483547
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, NPT
cable inlet, approval option E, with PROFIBUS
PA communication, no process connection.
A5E01483559
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, NPT
cable inlet, approval option A, with HART
communication start-up at < 3.6 mA,
no process connection.
A5E03617085
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 6.3 GHz, NPT
cable inlet, approval option B, with HART
communication start-up at < 3.6 mA,
no process connection.
A5E03617086
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, NPT
cable inlet, approval option C, with HART
communication start-up at < 3.6 mA,
no process connection.
A5E03617087
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 6.3 GHz, NPT
cable inlet, approval option E, with HART
communication start-up at < 3.6 mA,
no process connection.
A5E03617088
4
Sun shield for SITRANS LR200 enclosure,
stainless steel
A5E35497857
SITRANS LR200 Horn Antenna Kits
with mounting screws
(no emitter supplied)
SITRANS LR200 HART aluminum enclosure
kit with electronics and covers (7ML5422,
7ML5423, 7ML5424, 7ML5425), calibrated for
use with standard rod antenna
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option A, with HART
communication start-up at < 3.6 mA,
no process connection.
A5E02956419
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option E, with HART
communication start-up at < 3.6 mA,
no process connection.
A5E02956420
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option G, with HART
communication start-up at < 3.6 mA,
no process connection.
A5E02956421
SITRANS LR200 aluminum enclosure
with board stack, LUI display, 5.8 GHz, M20
cable inlet, approval option H, with HART
communication start-up at < 3.6 mA,
no process connection.
A5E02956422
80 mm (3 inch) horn antenna kit
PBD:25500K02A
100 mm (4 inch) horn antenna kit
PBD:25500K03A
150 mm (6 inch) horn antenna kit
PBD:25500K05A
200 mm (8 inch) horn antenna kit
PBD:25500K07A
SITRANS LR200 Extension Kits for
Horn Antenna with mounting screws
100 mm (4 inch) extension kit for horn antenna
PBD:25501K0100A
150 mm (6 inch) extension kit for horn antenna
PBD:25501K0150A
200 mm (8 inch) extension kit for horn antenna
PBD:25501K0200A
250 mm (10 inch) extension kit for horn antenna
PBD:25501K0250A
500 mm (20 inch) extension kit for horn antenna
PBD:25501K0500A
1 000 mm (40 inch) extension kit for
horn antenna
PBD:25501K1000A
Siemens FI 01 · 2016
4/213
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200 Specials
SITRANS LR200 Specials
SITRANS LR200 Specials
Article No.
SITRANS LR200 Flanged Rod Antenna Kit
with 316L stainless steel flat faced flanges
4
Flanged PTFE rod antenna kit, 2" ASME, 150 lb.
See drawing 51003 on
http://www.siemens.com/radar 1)4)
PBD:
51003K020AAAA
Flanged PTFE rod antenna kit, DN 50 PN 16.
See drawing 51003 on
http://www.siemens.com/radar 1)4)
PBD:
51003K050AJAA
Flanged PTFE rod antenna kit,
JIS 10K DN 50. See drawing 51003 on
http://www.siemens.com/radar 1)4)
PBD:
51003K050AOAA
SITRANS LR200 PTFE Rod Antenna Kit with
316L stainless steel 1½" pipe thread process
connection
PTFE rod antenna kit, 1½" NPT 316L stainless
steel process connection, FKM O-ring;
See drawing 51004 on
http://www.siemens.com/radar 4)
PBD:
51004K1AAA
PTFE rod antenna kit, R 1½" (BSPT),
EN 10226 316L stainless steel process
connection, FKM O-ring; see drawing 51004
on http://www.siemens.com/radar 4)
PBD:
51004K2AAA
PTFE rod antenna kit, 1½" G 316L stainless
steel process connection, FKM O-ring;
see drawing 51004 on
http://www.siemens.com/radar 4)
PBD:
51004K3AAA
SITRANS LR200 PTFE Rod Antenna Kit with
316L stainless steel 2" pipe thread process
connection
PTFE rod antenna kit, 2" NPT 316L stainless
steel process connection, FKM O-ring;
see drawing 51005 on
http://www.siemens.com/radar 4)
PBD:
51005K1AAA
PTFE rod antenna kit, R 2" (BSPT),
EN 10226 316L stainless steel process
connection, FKM O-ring; see drawing 51005 on
http://www.siemens.com/radar 4)
PBD:
51005K2AAA
PTFE rod antenna kit, 2" G 316L stainless steel
process connection, FKM O-ring;
see drawing 51005 on
http://www.siemens.com/radar 4)
PBD:
51005K3AAA
4/214
Siemens FI 01 · 2016
Article No.
SITRANS LR200 PTFE Rod Antenna Kit
(100 mm shield) with 316L stainless steel
2" pipe thread process connection
PTFE rod antenna shielded kit, 2" NPT 316L
stainless steel process connection,
FKM O-ring, 100 mm 316L stainless steel
shield. See drawing 51002 on
http://www.siemens.com/radar 3)4)
PBD:
51002K0100AAA
PTFE rod antenna shielded kit, R 2" (BSPT),
EN 10226 316L stainless steel process
connection, FKM O-ring, 100 mm 316L stainless
steel shield. See drawing 51002 on
http://www.siemens.com/radar 3)4)
PBD:
51002K0100BAA
PTFE rod antenna shielded kit, 2" G 316L
stainless steel process connection,
FKM O-ring, 100 mm 316L stainless steel
shield. See drawing 51002 on
http://www.siemens.com/radar 3)4)
PBD:
51002K0100CAA
SITRANS LR200 Horn Antenna Kit with 316L
stainless steel flat faced flange, with PTFE
emitter (without waveguide)
Horn antenna kit, 2" ASME 316L stainless steel
flange 3 inch horn, PTFE emitter1)4)
PBD:
51006K020AAAA
Horn antenna kit, 2" ASME 316L stainless steel
flange 4 inch horn, PTFE emitter1)2)
PBD:
51006K020AABA
Horn antenna kit, 2" ASME 316L stainless steel
flange 6 inch horn, PTFE emitter1)2)
PBD:
51006K020AACA
Horn antenna kit, 2" ASME 316L stainless steel
flange 8 inch horn, PTFE emitter1)2)
PBD:
51006K020AADA
Horn antenna kit, DN 50 PN 16 316L stainless
steel flange 80 mm horn, PTFE emitter1)2)
PBD:
51006K050AJAA
Horn antenna kit, DN 50 PN 16 316L stainless
steel flange 100 mm horn, PTFE emitter1)2)
PBD:
51006K050AJBA
Horn antenna kit, DN 50 PN 16 316L stainless
steel flange 150 mm horn, PTFE emitter1)2)
PBD:
51006K050AJCA
Horn antenna kit, DN 50 PN 16 316L stainless
steel flange 200 mm horn, PTFE emitter1)2)
PBD:
51006K050AJDA
© Siemens AG 2016
Level Measurement
Continuous level measurement - Radar transmitters
SITRANS LR200 Specials
SITRANS LR200 Specials
Article No.
SITRANS LR200 PTFE flanged rod antenna
kit with 316L stainless steel shield and 316L
stainless steel flat faced flange
PTFE shielded rod antenna kit, flanged,
3" ASME 150 lb 316L stainless steel flange,
100 mm 316L stainless steel shield.1)4)
PBD:
51014K0100AAA
PTFE shielded rod antenna kit, flanged,
DN 80 PN 16 316L stainless steel flange,
100 mm 316L stainless steel shield.1)4)
PBD:
51014K0100EJA
PTFE shielded rod antenna kit, flanged,
3" ASME 150 lb 316L stainless steel flange,
150 mm 316L stainless steel shield.1)4)
PBD:
51014K0150AAA
PTFE shielded rod antenna kit, flanged,
DN 80 PN 16 316L stainless steel flange,
150 mm 316L stainless steel shield.1)4)
PBD:
51014K0150EJA
PTFE shielded rod antenna kit, flanged,
3" ASME 150 lb 316L stainless steel flange,
200 mm 316L stainless steel shield.1)4)
PBD:
51014K0200AAA
PTFE shielded rod antenna kit, flanged,
DN 80 PN 16 316L stainless steel flange,
200 mm 316L stainless steel shield.1)4)
PBD:
51014K0200EJA
PTFE shielded rod antenna kit, flanged,
3" ASME 150 lb 316L stainless steel flange,
250 mm 316L stainless steel shield.1)4)
PBD:
51014K0250AAA
PTFE shielded rod antenna kit, flanged,
DN 80 PN 16 316L stainless steel flange,
250 mm 316L stainless steel shield.1)4)
PBD:
51014K0250EJA
4
PTFE paste
Kit, PTFE paste, tube, 250 ml
PBD:51036065
Cable gland
One polymeric cable gland M20 x 1.5,
rated -20 ... +80 °C (-4 ... +176 °F) for
General Purpose and ATEX EEx e
7ML1930-1AN
One metallic cable gland M20 x 1.5,
rated -40 ... +80 °C (-40 ... +176 °F), HART
7ML1930-1AP
One metallic cable gland M20 x 1.5,
rated -40 ... +80 °C (-40 ... +176 °F),
PROFIBUS PA
7ML1930-1AQ
1)
Available in flange sizes including ASME, DIN and JIS.
Please consult a local sales person for details.
2)
Available with no pressure rating.
Please consult a local sales person for details.
3)
Available in other shield lengths.
Please consult a local sales person for details.
4)
Available with Pressure rating.
Please consult a local sales person for details.
Customers interested in a custom designed device should consult a local
sales person. For more information, please visit
http://www.automation.siemens.com/aspa_app.
Siemens FI 01 · 2016
4/215