© Siemens AG 2016 Level Measurement Continuous level measurement - Ultrasonic controllers HydroRanger 200 ■ Overview ■ Application For water authorities, municipal water, and wastewater plants, HydroRanger 200 is an economical, low-maintenance solution delivering control efficiency and productivity needed to meet today’s exacting standards. It offers single point monitoring with all models, and optional dual-point monitoring with 6 relay model. As well, it has digital communications with built-in Modbus RTU via RS 485. The standard 6 relay HydroRanger 200 will monitor open channel flow and features more advanced relay alarming and pump control functions as well as volume conversion. It is compatible with SIMATIC PDM, allowing for PC configuration and setup. Sonic Intelligence advanced echo-processing software provides increased reading reliability. The optional 1 or 3 relay models provide accurate level measurement functions only; these two models do not provide open channel flow, differential level measurement or volume conversion functions. HydroRanger 200 is an ultrasonic level controller for up to six pumps and provides control, differential control, and open channel flow monitoring. ■ Benefits • Monitors wet wells, weirs and flumes • Digital communications with built-in Modbus RTU via RS 485 • Compatible with SmartLinx system and SIMATIC PDM configuration software • Single or dual point level monitoring • 6 relay (standard), 1 or 3 relay (optional) • Auto False-Echo Suppression for fixed obstruction avoidance • Anti-grease ring/tide mark buildup • Differential amplifier transceiver for common mode noise rejection and improved signal-to-noise ratio • Wall and panel mounting options HydroRanger 200 uses proven continuous ultrasonic echo ranging technology to monitor water and wastewater of any consistency up to 15 m (50 ft) in depth. Achievable resolution is 0.1 % with accuracy to 0.25 % of range. Unlike contacting devices, HydroRanger 200 is immune to problems caused by suspended solids, harsh corrosives, grease or silt in the effluent, reducing downtime. • Key Applications: wet wells, flumes/weirs, bar screen control Siemens FI 01 · 2016 4/169 4 © Siemens AG 2016 Level Measurement Continuous level measurement - Ultrasonic controllers HydroRanger 200 ■ Technical specifications Design Mode of Operation Measuring principle Ultrasonic level measurement Measuring range 0.3 ... 15 m (1 ... 50 ft), transducer dependent Weight • Wall mount • Panel mount 1.37 kg (3.02 lb) 1.50 kg (3.31 lb) Measuring points 1 or 2 Material (enclosure) Polycarbonate Degree of protection (enclosure) • Wall mount • Panel mount IP65/Type 4X/NEMA 4X IP54/Type 3/NEMA 3 Input Analog 0 ... 20 mA or 4 ... 20 mA, from alternate device, scalable (6 relay model) Discrete 10 ... 50 V DC switching level Logical 0 0.5 V DC Logical 1 = 10 ... 50 V DC Max. 3 mA Cable Transducer and mA output signal 2-core copper conductor, twisted, shielded, 300 Vrms, 0.82 mm² (18 AWG), Belden 8 760 or equivalent is acceptable Max. separation between transducer and transceiver 365 m (1 200 ft) Displays and controls 100 x 40 mm (4 x 1.5 inch) multiblock LCD with backlighting Programming Programming using handheld programmer or via PC with SIMATIC PDM software Output 4 EchoMax transducer 44 kHz Ultrasonic transducer Compatible transducers: ST-H and EchoMax series XPS-10, XPS 15/15F, and XRS-5 Relays1) • Model with 1 relay2) • Model with 3 relays2) • Model with 6 relays Rating 5 A at 250 V AC, non-inductive 1 SPST Form A 2 SPST Form A/1 SPDT Form C 4 SPST Form A/2 SPDT Form C mA output • Max. load • Resolution 0 ... 20 mA or 4 ... 20 mA 750 , isolated 0.1 % of range Accuracy Error in measurement 0.25 % of range or 6 mm (0.24 inch), whichever is greater Resolution 0.1 % of measuring range or 2 mm (0.08 inch), whichever is greater3) Temperature compensation • -50 ... +150 °C (-58 ... +302 °F) • Integral temperature sensor in transducer • External TS-3 temperature sensor (optional) • Programmable fixed temperature values Power supply4) AC version 100 ... 230 V AC ± 15 %, 50/60 Hz, 36 VA (17 W) DC version 12 ... 30 V DC (20 W) Certificates and approvals • • • • • Communication • RS 232 with Modbus RTU or ASCII via RJ-11 connector • RS 485 with Modbus RTU or ASCII via terminal blocks • Optional: SmartLinx cards for - PROFIBUS DP - DeviceNet Rated operating conditions Installation conditions Location 1) Indoor / outdoor Installation category II Pollution degree 4 Ambient conditions Ambient temperature (enclosure) 4/170 Siemens FI 01 · 2016 -20 ... +50 °C (-4 ... +122 °F) CE, RCM5) Lloyd's Register of Shipping ABS Type Approval FM, CSAUS/C, UL listed CSAUS/C Class I, Div. 2, Groups A, B, C, and D, Class II, Div. 2, Groups F and G, Class III (wall mount only) • MCERTS Class 3 approved for Open Channel Flow All relays certified for use with equipment that fails in a state at or under the rated maximums of the relays This model is level control only; no open channel flow, differential level or volume conversion functions 3) Program range is defined as the empty distance to the face of the transducer plus any range extension 4) Maximum power consumption is listed 5) EMC performance available upon request 2) © Siemens AG 2016 Level Measurement Continuous level measurement - Ultrasonic controllers HydroRanger 200 Selection and Ordering data Article No. Selection and Ordering data Siemens HydroRanger 200 Ultrasonic level controller for up to six pumps that provides control, differential control and open channel flow monitoring. The HydroRanger 200 is also available as a level measurement controller only. Select option from number of measurement points options below. 7ML5034- Further designs Please add "-Z" to Article No. and specify Order code(s). 777 77 Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Mounting Wall mount, standard enclosure Wall mount, 4 entries, 4 M20 cable glands included Panel mount1) Power supply 100 ... 230 V AC 12 ... 30 V DC Number of measurement points Single point model, 6 relays Dual point model, 6 relays Single point model, level only, 1 relay2) Single point model, level only, 3 relays2) Communication (SmartLinx) Without module SmartLinx PROFIBUS DP module SmartLinx DeviceNet module See SmartLinx product on page 4/374 for more information. Approvals General Purpose CE, FM, CSAUS/C, UL listed, RCM CSA Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; Class III (for wall mount applications only) 1) 2) 1 2 3 A B A B C D Order code Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Measuring-point number/identification (max. 27 characters) specify in plain text Y15 Operating Instructions Article No. English 7ML1998-5FC03 German Note: The Operating Instructions should be ordered as a separate item on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and Operating Instructions library. 7ML1998-5FC33 4 Other Operating Instructions 0 2 SmartLinx PROFIBUS DP, English 7ML1998-1AQ03 SmartLinx PROFIBUS DP, German 7ML1998-1AQ33 SmartLinx DeviceNet, English 7ML1998-1BH02 Note: The appropriate SmartLinx Operating Instructions should be ordered as a separate line on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation 3 1 2 Available with approval option 1 only This model is level control only; no open channel flow, differential level, or volume conversion functions. Accessories Handheld programmer A5E36563512 Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch), one text line, suitable for enclosure 7ML1930-1AC Sunshield kit, 304 stainless steel 7ML1930-1GA SITRANS RD100, loop powered display see Chapter 7 7ML5741-... SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 7ML5740-... SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion see Chapter 7 7ML5744-... SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 7ML5750-... Spare parts Power Supply Board (100 ... 230 V AC) 7ML1830-1MD Power Supply Board (12 ... 30 V DC) 7ML1830-1ME MultiRanger 100/200/ HydroRanger 200 display, non-HMI 7ML1830-1MF Siemens FI 01 · 2016 4/171 © Siemens AG 2016 Level Measurement Continuous level measurement - Ultrasonic controllers HydroRanger 200 ■ Dimensional drawings ■ Schematics Wall mount version 14.9 160.3 (6.325) (0.58) 15.2 130 (5.125) (0.6) Mounting holes Ø 4.3 (0.17) (x4) TB1 See note 1 6.6 (0.26) 91 (3.58) TB1 TB2 + 240 (9.45) 227 (8.93) Cover screws (x6) L2/N L1 - - + 2 TB3 12-30 V SYNC 1 DC version + mA INPUT + SHIELD Relay 1 1 Panel mount version 198 (7.80) + + Relay 3 TS-3 Hand programmer 36 (1.40) + 2 1 2 000 00 0 00 5 6 9 0 mA 3 4 7 8 P PX X X SHIELD 1 Relay 4 97 (3.82) Relay 5 DISCRETE INPUTS 2 COM Relay 6 C 278 (10.94) 4 4 ... 20 mA OUTPUTS Relay 2 Housing Mounting screw (provided by customer) Siemens Mounting holes recommends using a hole (accessed under lid) punch for drilling the holes. Ø 4.3 (0.17) (x4) Suitable location for conduit entrances Relays shown in released state Article number: A5E36563512 RS 485 A B Notes 1. Use 2-core copper wire, twisted, with shield, for expansion up to 365 m (1 200 ft.). Route cable in grounded metal conduit, separate from other cables. 2. Verify that all system components are installed in accordance with instructions. 3. Connect all cable shields to the HydroRanger 200 shield connections. Avoid differential ground potentials by not connecting cable shields to ground (earth) anywhere else. HydroRanger 200, dimensions in mm (inch) 4. Keep exposed conductors on shielded cables as short as possible to reduce noise on the line caused by stray transmissions and noise pickup. HydroRanger 200 connections 4/172 Siemens FI 01 · 2016