Data Sheet • Mann Series Pa n e l m o u n t , To t a l i s e r/C o u n t e r s P T X 8 0 0 A C u r re n t / Vo l t a g e I n p u t s PTX800D Digital Pulse Inputs These units are available in two models: the PTX800A for analogue current/voltage rate signals; and the PTX800D with digital pulse outputs. • • • • • • • • • • • • Display total or rate in any engineering unit Bright 8 digit LED display Up to 2 alarm channels Optional analogue output Pulse output Reset pulse input Last count retention in case of power failure AC or DC powered Fully Isolated LED alarm status indication 1/8 DIN standard facia with IP65 rating Integral power supply for active input devices You can set the display for total or rate indication, then simply hold down the ‘rate/ total’ button to check the other value. % \ Australia Weidmüller Pty Ltd. 43 Huntingwood Drive, Huntingwood NSW 2148 Phone +61 (0) 2 9671 9999 Fax +61 (0) 2 9671 9900 [email protected] www.mannseries.com United Kingdom Other countries Weidmüller Ltd. 1 Abbey Wood Road, Kings Hill West Malling, Kent ME19 4YT Phone +44 1732-877032 Fax +44 1732-873873 [email protected] www.weidmueller.com Weidmüller Interface GmbH & Co. Postfach 3030 32720 Detmold Phone +495231-14-0 Fax +495231-14-2083 [email protected] www.weidmueller.com Panel mount, Totaliser/Counters NN Connections NN NN Pin Signal 1 Neutral / − 2 Live / + 3 Signal + 4 Signal − 5 0V 6 Pulse NN NN Power supply PGM ENT 1"/&-5)*$,/&44.BYNN TOTAL RATE Pulse output RESET 7 NNNN $65065 NN NN NN 8 NNNN NN NN ("4,&5 AL2 AL1 Analogue output (optional) 9 Inputs (see individual units) 10 11 12 13 Normally Closed 14 Common 15 Normally Open 16 Normally Closed 17 Common 18 Normally Open Alarm one (optional) Alarm two (optional) Technical Data Display Type Full 8 digit, red 7.2 mm LED Display brightness Programmable (in 14 steps) Scaling Rate display Type Analogue current/voltage (jumper selectable) to display in % or engineering units Range Rates are displayed as up to fi ve digit numbers (from 0-50,000) Determined by calibration (in the range 0–22 mA or 0–11 V) Output resolution 1.6μA or 0.8mV per bit Current drive Up to 900Ω load (at 20mA) Note: loop compliance is 18V Voltage drive True voltage source (up to 20mA) Output ripple Less than 20mV P/P Rate timebase Rates can be displayed per second, minute or hour (also per day for the PTX800A only) Total display Totals are displayed as up to eight digit numbers (from 0-99,999,999) Decimal points Status indicators Analogue output (optional) General The decimal points can be selected separately for rate and total displays (up to three decimal places) Accuracy Better than 0.05% Linearity Better than 0.05% Alarm channel 1, Alarm channel 2 and key status Repeatability ±0.02% of span Temperature drift Less than 0.02% span/°C Long term drift 0.1% per 10,000 hours Power supply Type AC or DC powered AC (selectable) 110V/240V (47-63Hz) DC 24Vdc Other voltages on request Permissible range +15% to -10% (AC supply) ±10% (DC supply) Power usage AC 6VA or 6W at 24Vdc Insulation Co-ordination Reset pulse input Contact closure Effect Resets total and clears any total alarms Pulse output Rated Insulation Voltage 300Veff Overvoltage Category III Impulse Withstand 4kV (1.2 / 50) Isolation 2 kV (between ports) Operating temperature 0 to 60 °C Storage temperature –25 to +70 °C Pollution Degree 2 Relative humidity 10–90% (non–condensing) NPN O/C transistor type (isolated) Scaling One pulse per integer change in total Pulse width 32 millisecond Off time 32 millisecond minimum Max pulse rate 15 pulses per second Alarm outputs (optional) Type SPDT relay contacts Rating 3A at 240Vac (resistive) 3A 24Vdc/110Vac (resistive) Isolation 1.5kV between channels Page 2 Input / Output / Relay One, Relay Two / Power Supply Environmental Conditions Type Type Ports Housing Type Double Insulated, Panel mount IP rating IP65 (from front of panel) Front bezel 1/8 DIN format Approvals Mark Standard DC Powered units only \ E256486 CAN/CSA C22.2 No. 1010.1:92 UL61010-1: 2004 % LV Directive EMC EN50178:1998 BS EN 61326:1998 + A2 Subject to technical alterations without notice • Printed in Australia • 7940015649 • 25/10/2007 Panel mount, Totaliser/Counters % % \ \ PTX800D Digital Pulse Inputs Scaleable pulse counter and rate indicator for digital pulse signals. • Flexible inputs suit a wide range of digital input sensors and signals • Power for active input devices PTX800A Current/Voltage Inputs Programmable Integrating Totaliser and rate indicator for current/voltage signals. • Inbuilt square law function • Power for active input devices • Programmable low cut-out rate Type Digital pulse, including: NAMUR sensors; 3-wire PNP/NPN sensors; PNP/NPN open collector outputs; TTL logic; Solid State Switches; Low and high voltage pulses; and Volt-free contacts Linear or square law, rate signal in analogue current or voltage format. Range is determined by the calibration values used. Input range 0 to 10 kHz –24.00 to +24.00 mA or -11.00 to +11.00 V Sensor power output Nominally 12 Vdc (to 25 mA) Other voltages on request (/FPS option) Nominally 24Vdc (to 25mA) Other voltages on request (/FPS Option) Input voltage range Programmable from 50 mV to 250 V peak Technical Data Inputs Resolution 0.6μA/0.3mV Input impedance Rate to Total scaling 22Ω (current)/1MΩ (voltage) Programmable (up to 10,000 pulses per unit change in total) Select from 0.001, 0.01, 0.1, 1, 10, 100 or 1,000 Proportional to rate or total Proportional to rate only Close for 100mS minimum Close for 250mS minimum 16 pulses per second 15 pulses per second /AO With analogue output fi tted (specify format), e.g., PTX800D/.../AO/4-20mA With analogue output fi tted (specify format), e.g., PTX800A/.../AO/4-20mA /RO With dual alarms With alarm channels three and four fi tted /FPS Custom input sensor supply voltage. State voltage, e.g., PTX800D/.../FPS/24Vdc Custom input sensor supply voltage. State voltage, e.g., PTX800A/.../FPS/24Vdc Terminal Signal Terminal Signal 7 Reset count Short to 12 to reset 7 Reset count 8 Security Short to 12 for setup 8 Common Analogue output (optional) Type Reset input Timing Pulse output Max pulse rate Options Input Connections 9 Pull Up/Down 9 Security 10 Input − / 0 V 10 Input − / 0 V 11 Input + 11 Input + 12 +12Vdc (out) 12 +24Vdc (out) Short to 8 to reset Short to 8 for setup Inputs Inputs Ordering Information Type (Model 1/2 - See key below) Cat. No. Type (Model 1/2 - See key below) Cat. No. PTX800D 24Vdc 7940011133 PTX800A 4-20mA/24Vdc 7940010243 PTX800D 24Vdc/ROAO 7940012323 PTX800A 4-20mA/24Vdc/ROAO 7940014374 Note: For other ranges please specify PTX800D 1/2 where: 1 = Power Supply Voltage, 2 = Options Page 3 Note: For other ranges please specify PTX800A 1/2/3 where: 1 = Input format, 2 = Power supply voltage, 3 = Options Subject to technical alterations without notice • Printed in Australia • 7940015649 • 25/10/2007