SITRANS CU02 Catalog sheet

© Siemens AG 2016
Process Protection
Acoustic sensors for material flow monitoring
SITRANS CU02 control unit
■ Overview
■ Technical specifications
Mode of operation
Measuring principle
Controller for acoustic sensing
(SITRANS AS100)
Typical application
Connects to SITRANS AS100 to
detect burst filter bag
Input
0 … 10 V DC, from sensor
Output
Output signal
4 … 20 mA isolated output,
2 Form C relays - latching or
non-latching - 5 amp at 250 V AC
non-inductive
Sensor excitation
26 V DC
Max. load
750 
Rated operating conditions
Installation conditions
• Location
SITRANS CU02 is an alarm control unit, for use with
SITRANS AS100 acoustic sensor, that provides reliable continuous protection for bulk solids flow.
■ Benefits
6
•
•
•
•
•
•
4 to 20 mA output
Two programmable relays
Adjustable independent time delay for each relay
Adjustable start-up time delay
DIN rail mounting provides easy installation
Built-in password protection to parameters
■ Application
SITRANS CU02 receives a 0 to 10 V DC input signal from the
SITRANS AS100 sensor, providing relay and analog outputs for
interface into a process.
• Key applications: with SITRANS AS100 for bulk solids flow
• Degree of protection
• Installation category
• Pollution degree
Indoor
-20 … +50 °C (-4 … +122 °F)
80 % for temperatures up to 50 °C
(122 °F)
IP20
II
2
Design
Weight
550 g (18 oz)
Dimensions (W x H x D)
55 x 75 x 110 mm (2.2 x 3 x 4.4 inch)
Material enclosure
Polycarbonate
Mounting
DIN Rail (DIN 46277 or DIN
EN 50022), or wall mount, up to
500 m (1 500 ft) from sensor
Cable
2 twisted pair, 24 AWG (22 mm²),
shielded. Mount up to 500 m
(1 500 ft) from sensor
Display
Liquid crystal, three digits, 9 mm
(0.35 inch), high and multi-segment
graphic symbols for operation status
Power supply
■ Function
The system can be readily configured for set points indicating
such conditions as high flow, low flow or no flow. Alternatively, it
can be added to a control loop via a 4 to 20 mA isolated output
for trend monitoring proportional to the signal from the sensor.
Two relays are fully programmable and independent of each
other and can be used to operate an alarm or control device.
Alarming may be provided above or below a setpoint or within a
band. Readings are also displayed locally by the SITRANS
CU02 on its LCD.
The SITRANS CU02 may be mounted up to 500 m (1 500 ft) from
the sensor.
6/14
Ambient conditions
• Ambient temperature for enclosure
• Relative humidity
Siemens FI 01 · 2016
Supply voltage
100, 115, 200, 230 V AC ± 15 %,
50/60 Hz, factory set
Power consumption
Max. 10 VA
Approvals
CSAUS/C, CE, RCM, EAC
© Siemens AG 2016
Process Protection
Acoustic sensors for material flow monitoring
SITRANS CU02 control unit
Selection and Ordering data
Article No.
Selection and Ordering data
SITRANS CU02 Control Unit
Alarm control unit for use with SITRANS AS100
acoustic sensor to provide reliable continuous
protection for bulk solid flow
7 MH7 5 6 2 -
Further designs
777
Please add "-Z" to Article No. and specify Order
code(s).
Manufacturer’s test certificate: According to
EN 10204-2.2
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Power Supply
100 V AC
115 V AC
200 V AC
230 V AC
Order code




Enclosure
Standard DIN Rail

Approvals
CSAUS/C, CE, RCM

 C11
Acrylic coated, stainless steel tag [38 x 51 mm
 Y18
(1.5 x 2 inch)]: Measuring-point number/identification
(max. 16 characters), specify in plain text
1
2
3
4
A
A
 We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol . For details see page 9/5 in the appendix.
Operating Instructions
Article No.
English
7ML1998-5DN01
German
7ML1998-5DN31
Note: The operating instructions should be ordered
as a separate item on the order.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
This device is shipped with the Siemens Level and
Weighing manual DVD containing the complete
operating instructions library.
 We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol . For details see page 9/5 in the appendix.
■ Dimensional drawings
6
Wall/panel mounting
110
(4.4)
61 (2.4)
75 (3)
61 (2.4)
38
(1.5)
Drill and tap for
Ø4 (#8) screw,
(2 places)
55
(2.2)
38
(1.5)
4.5 x 5.75 (0.18 x 0.2)
Mounting slot (2 places)
SITRANS CU02, dimensions in mm (inch)
Siemens FI 01 · 2016
6/15
© Siemens AG 2016
Process Protection
Acoustic sensors for material flow monitoring
SITRANS CU02 control unit
■ Schematics
Excitation
voltage
0 ... 10 V DC
signal I/P
Analog
output
*
1
mA
2
+
out
3
Vsup
4
5
6
7
8
latch
com Vsens
* Jumper allows
automatic reset or
use remote push
button to unlatch
4-20
100, 115, 200,
230 V AC, 10 VA
Factory set
RL1
9
10
RL2
11
12
13
14
L1
L2
N
15
16
Standard temperature version
red
blk
grn
blk
or*
blk
wht
shield
6
* Sensor range selection
High sensitivity range = green to 'Vsup'
Low sensitivity range = green to 'com'
Extended temperature version
red
blk
orange
grn
or*
brw
yel
shield
* Sensor range selection
High sensitivity range = orange to 'Vsup'
Low sensitivity range = orange to 'com'
Mounting
Installation shall only be performed by qualified personnel and in
accordance with local governing regulations.
This product is susceptible to electrostatic shock. Follow proper
grounding procedures.
Interconnection
All field wiring must have insulation suitable for at least 250 V.
Relay contact terminals are for use with equipment having no
accessible live parts and wiring having insulation suitable for at least
250 V.
The maximum allowable working voltage between adjacent relay
contacts shall be 250 V. If sensor case is grounded, do not connect
shield of cable to SITRANS CU02 ground terminal.
SITRANS CU02 connections
6/16
Siemens FI 01 · 2016