© Siemens AG 2016 Level Measurement Continuous level measurement - Ultrasonic controllers MultiRanger 100/200 ■ Overview ■ Application MultiRanger can be used on different materials, including fuel oil, municipal waste, acids, woodchips, or on materials with high angles of repose. MultiRanger offers true dual point monitoring, digital communications with built-in Modbus RTU via RS 485, as well as compatibility with SIMATIC PDM, allowing PC configuration and setup. MultiRanger features Sonic Intelligence advanced echo-processing software for increased reading reliability. MultiRanger 100 offers cost-effective level alarming, as well as on/off and alternating pump control. MultiRanger 200 will monitor open channel flow and features more advanced relay alarming and pump control functions as well as volume conversion. It is compatible with chemical-resistant EchoMax transducers that can be used in hostile environments at temperatures as high as 145 °C (293 °F). • Key Applications: wet wells, flumes/weirs, bar screen control, hoppers, chemical storage, liquid storage, crusher bins, dry solids storage MultiRanger is a versatile short to medium-range ultrasonic single and multi-vessel level monitor/controller for virtually any application in a wide range of industries. ■ Benefits ■ Design The MultiRanger is available in wall or panel mounting options. • Digital input for back-up level override from point level device • Communication using built-in Modbus RTU via RS 485 • Compatible with SmartLinx system and SIMATIC PDM configuration software • Single or dual point level monitoring • Auto False-Echo Suppression for fixed obstruction avoidance • Differential amplifier transceiver for common mode noise reduction and improved signal-to-noise ratio • MultiRanger 100: level measurements, simple pump control, and level alarm functions • MultiRanger 200: level, volume, and flow measurements in open channels, differential control, extended pump control, and alarm functions • Wall and panel mounting options Siemens FI 01 · 2016 4/161 4 © Siemens AG 2016 Level Measurement Continuous level measurement - Ultrasonic controllers MultiRanger 100/200 ■ Technical specifications Design Mode of Operation Measuring principle Ultrasonic level measurement Measuring range 0.3 ... 15 m (1 ... 50 ft) Measuring points 1 or 2 Input Weight • Wall mount • Panel mount 1.37 kg (3.02 lb) 1.50 kg (3.31 lb) Material (enclosure) Polycarbonate Degree of protection (enclosure) • Wall mount • Panel mount IP65/Type 4X/NEMA 4X IP54/Type 3/NEMA 3 Analog (MultiRanger 200 only) 0 ... 20 mA or 4 ... 20 mA, from alternate device, scalable Discrete 10 ... 50 V DC switching level Logical 0 0.5 V DC Logical 1 = 10 ... 50 V DC Max. 3 mA Electrical connection Transducer and mA output signal 2-core copper conductor, twisted, shielded, 0.5 ... 0.75 mm² (22 ... 18 AWG), Belden 8760 or equivalent is acceptable EchoMax transducer 44 kHz Compatible transducers: ST-H and EchoMax series XPS-10, XPS 15/15F, and XRS-5 Max. separation between transducer and transceiver 365 m (1 200 ft) Ultrasonic transducer Displays and controls 100 x 40 mm (4 x 1.5 inch) multiblock LCD with backlighting Programming using hand-held programmer, SIMATIC PDM or via PC with Dolphin Plus software Output 4 Relays • Version with 1 relay (MultiRanger 100 only) • Version with 3 relays • Version with 6 relays Rating 5 A at 250 V AC, non-inductive 1 SPST Form A Programming 2 SPST Form A/1 SPDT Form C 4 SPST Form A/2 SPDT Form C Power supply mA output • Max. load • Resolution 0 ... 20 mA or 4 ... 20 mA 750 , isolated 0.1 % of range Accuracy Error in measurement 0.25 % of range or 6 mm (0.24 inch), whichever is greater Resolution 0.1 % of measuring range1) or 2 mm (0.08 inch), whichever is greater Temperature compensation • -50 ... +150 °C (-58 ... +302 °F) • Integral temperature sensor • External TS-3 temperature sensor (optional) • Programmable fixed temperature values AC version 100 ... 230 V AC ± 15 %, 50/60 Hz, 36 VA (17 W) DC version 12 ... 30 V DC (20 W) Certificates and approvals • • • • • Communication • RS 232 with Modbus RTU or ASCII via RJ-11 connector • RS 485 with Modbus RTU or ASCII via terminal strips • Optional: SmartLinx cards for - PROFIBUS DP - DeviceNet Rated operating conditions 1) Installation conditions Location Indoor/outdoor Installation category II Pollution degree 4 Ambient conditions Ambient temperature (housing) 4/162 Siemens FI 01 · 2016 -20 ... +50 °C (-4 ... +122 °F) CE, RCM2) Lloyd’s Register of Shipping ABS Type Approval FM, CSAUS/C, UL listed CSA Class I, Div. 2, Groups A, B, C, and D, Class II, Div. 2, Groups F and G, Class III (wall mount only), ATEX II 3D Program range is defined as the empty distance to the face of the transducer plus any range extension 2) EMC performance available on request © Siemens AG 2016 Level Measurement Continuous level measurement - Ultrasonic controllers MultiRanger 100/200 Selection and Ordering data Article No. Selection and Ordering data MultiRanger 100/200 Versatile short to medium-range ultrasonic single and multi-vessel level monitor/controller for virtually any application in a wide range of industries 7ML5033- Further designs 7 7 7 77 - 77 Please add "-Z" to Article No. and specify Order code(s). Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]: Y15 Measuring-point number/identification (max. 27 characters) specify in plain text Click on the Article No. for the online configuration in the PIA Life Cycle Portal. Versions MultiRanger 100, level measurement only 1 MultiRanger 200, level, volume, flow, and differen- 2 tial measurements Mounting, enclosure design Wall mount, standard enclosure Wall mount, 4 entries, 4 M20 cable glands included Panel mount (CE, CSAUS/C, FM, UL) Power supply 100 ... 230 V AC 12 ... 30 V DC Number of measurement points Single point version Dual point version Communication (SmartLinx) Without module SmartLinx PROFIBUS DP module SmartLinx DeviceNet module See SmartLinx product on page 4/374 for more information. Output relays 3 relays (2 Form A, 1 Form C), 250 V AC 6 relays (4 Form A, 2 Form C), 250 V AC 1 relay (1 Form A), 250 V AC (available on MultiRanger 100 model only) 2) A B C A B Article No. English 7ML1998-5FB06 German 7ML1998-5FB36 4 Other Operating Instructions 0 1 0 2 3 Operating Instructions Note: The Operating Instructions should be ordered as a separate item on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation This device is shipped with the Siemens Level and Weighing manual DVD containing the ATEX Quick Start and Operating Instructions library. Approvals General Purpose CE, FM, CSAUS/C, UL listed, RCM CSA Class I, Div. 2, Groups A, B, C, and D; Class II, Div. 2, Groups F and G; Class III1) ATEX II 3D2) 1) Order code 1 2 3 SmartLinx PROFIBUS DP, English 7ML1998-1AQ03 SmartLinx PROFIBUS DP, German 7ML1998-1AQ33 SmartLinx DeviceNet, English Note: The appropriate SmartLinx Operating Instructions should be ordered as a separate line on the order. All literature is available to download for free, in a range of languages, at http://www.siemens.com/ processinstrumentation/documentation 7ML1998-1BH02 Accessories Handheld programmer A5E36563512 Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch), one text line, suitable for enclosure 7ML1930-1AC A B M20 cable gland kit (4 M20 cable glands, 4 M20 nuts, 4 washers) 7ML1930-1FV C Sunshield kit, 304 stainless steel 7ML1930-1GA SITRANS RD100, loop powered display see Chapter 7 7ML5741-... SITRANS RD200, universal input display with Modbus conversion - see Chapter 7 7ML5740-... SITRANS RD300, dual line display with totalizer and linearization curve and Modbus conversion see Chapter 7 7ML5744-... SITRANS RD500 web, universal remote monitoring solution for instrumentation - see Chapter 7 7ML5750-... For wall mount applications only For standard enclosure wall mount, option A only We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Spare parts Power Supply Board (100 ... 230 V AC) 7ML1830-1MD Power Supply Board (12 ... 30 V DC) 7ML1830-1ME MultiRanger 100/200/ HydroRanger 200 display, non-HMI 7ML1830-1MF We can offer shorter delivery times for configurations designated with the Quick Ship Symbol . For details see page 9/5 in the appendix. Siemens FI 01 · 2016 4/163 © Siemens AG 2016 Level Measurement Continuous level measurement - Ultrasonic controllers MultiRanger 100/200 ■ Dimensional drawings ■ Schematics Wall mount version 14.9 160.3 (6.325) (0.58) 15.2 130 (5.125) (0.6) Mounting holes Ø 4.3 (0.17) (x4) TB1 See note 1 6.6 (0.26) 91 (3.58) TB1 TB2 + 240 (9.45) 227 (8.93) Cover screws (x6) L2/N L1 - - + 2 TB3 12 ... 30 V SYNC 1 DC version + mA INPUT + SHIELD Relay 1 1 Panel mount version 198 (7.80) + + Relay 3 TS-3 Hand programmer 36 (1.40) + 2 1 2 000 00 0 00 5 6 9 0 mA 3 4 7 8 P PX X X SHIELD 1 Relay 4 97 (3.82) Relay 5 DISCRETE INPUTS 2 COM Relay 6 C 278 (10.94) 4 4 ... 20 mA OUTPUTS Relay 2 Housing Mounting screw (provided by customer) Siemens Mounting holes recommends using a hole (accessed under lid) punch for drilling the holes. Ø 4.3 (0.17) (x4) Suitable location for conduit entrances Relays shown in released state Article number: A5E36563512 RS 485 A B Note: 1. Use 2-core copper wire, twisted, with shield, for expansion up to 365 m (1 200 ft). Route cable in grounded metal conduit, separate from other cables. 2. Verify that all system components are installed in accordance with instructions. MultiRanger 100/200, dimensions in mm (inch) 3. Connect all cable shields to the MultiRanger shield connections. Avoid differential ground potentials by not connecting cable shields to ground (earth) anywhere else. 4. Keep exposed conductors on shielded cables as short as possible to reduce noise on the line caused by stray transmissions and noise pickup. MultiRanger 100/200 connections 4/164 Siemens FI 01 · 2016