MultiRanger 100/200 Catalog Specifications Sheet

© Siemens AG 2016
Level Measurement
Continuous level measurement - Ultrasonic controllers
MultiRanger 100/200
■ Overview
■ Application
MultiRanger can be used on different materials, including fuel
oil, municipal waste, acids, woodchips, or on materials with high
angles of repose. MultiRanger offers true dual point monitoring,
digital communications with built-in Modbus RTU via RS 485, as
well as compatibility with SIMATIC PDM, allowing PC configuration and setup. MultiRanger features Sonic Intelligence
advanced echo-processing software for increased reading
reliability.
MultiRanger 100 offers cost-effective level alarming, as well as
on/off and alternating pump control. MultiRanger 200 will monitor
open channel flow and features more advanced relay alarming
and pump control functions as well as volume conversion.
It is compatible with chemical-resistant EchoMax transducers
that can be used in hostile environments at temperatures as high
as 145 °C (293 °F).
• Key Applications: wet wells, flumes/weirs, bar screen control,
hoppers, chemical storage, liquid storage, crusher bins, dry
solids storage
MultiRanger is a versatile short to medium-range ultrasonic single and multi-vessel level monitor/controller for virtually any application in a wide range of industries.
■ Benefits
■ Design
The MultiRanger is available in wall or panel mounting options.
• Digital input for back-up level override from point level device
• Communication using built-in Modbus RTU via RS 485
• Compatible with SmartLinx system and SIMATIC PDM configuration software
• Single or dual point level monitoring
• Auto False-Echo Suppression for fixed obstruction avoidance
• Differential amplifier transceiver for common mode noise
reduction and improved signal-to-noise ratio
• MultiRanger 100: level measurements, simple pump control,
and level alarm functions
• MultiRanger 200: level, volume, and flow measurements in
open channels, differential control, extended pump control,
and alarm functions
• Wall and panel mounting options
Siemens FI 01 · 2016
4/161
4
© Siemens AG 2016
Level Measurement
Continuous level measurement - Ultrasonic controllers
MultiRanger 100/200
■ Technical specifications
Design
Mode of Operation
Measuring principle
Ultrasonic level measurement
Measuring range
0.3 ... 15 m (1 ... 50 ft)
Measuring points
1 or 2
Input
Weight
• Wall mount
• Panel mount
1.37 kg (3.02 lb)
1.50 kg (3.31 lb)
Material (enclosure)
Polycarbonate
Degree of protection (enclosure)
• Wall mount
• Panel mount
IP65/Type 4X/NEMA 4X
IP54/Type 3/NEMA 3
Analog (MultiRanger 200 only)
0 ... 20 mA or 4 ... 20 mA, from alternate device, scalable
Discrete
10 ... 50 V DC switching level
Logical 0  0.5 V DC
Logical 1 = 10 ... 50 V DC
Max. 3 mA
Electrical connection
Transducer and mA output signal
2-core copper conductor, twisted,
shielded, 0.5 ... 0.75 mm²
(22 ... 18 AWG), Belden 8760 or
equivalent is acceptable
EchoMax transducer
44 kHz
Compatible transducers: ST-H and
EchoMax series XPS-10, XPS 15/15F,
and XRS-5
Max. separation between transducer
and transceiver
365 m (1 200 ft)
Ultrasonic transducer
Displays and controls
100 x 40 mm (4 x 1.5 inch) multiblock LCD with backlighting
Programming using hand-held programmer, SIMATIC PDM or via PC
with Dolphin Plus software
Output
4
Relays
• Version with 1 relay (MultiRanger 100
only)
• Version with 3 relays
• Version with 6 relays
Rating 5 A at 250 V AC, non-inductive
1 SPST Form A
Programming
2 SPST Form A/1 SPDT Form C
4 SPST Form A/2 SPDT Form C
Power supply
mA output
• Max. load
• Resolution
0 ... 20 mA or 4 ... 20 mA
750 , isolated
0.1 % of range
Accuracy
Error in measurement
0.25 % of range or 6 mm (0.24 inch),
whichever is greater
Resolution
0.1 % of measuring range1)
or 2 mm (0.08 inch), whichever is
greater
Temperature compensation
• -50 ... +150 °C (-58 ... +302 °F)
• Integral temperature sensor
• External TS-3 temperature sensor
(optional)
• Programmable fixed temperature
values
AC version
100 ... 230 V AC ± 15 %,
50/60 Hz, 36 VA (17 W)
DC version
12 ... 30 V DC (20 W)
Certificates and approvals
•
•
•
•
•
Communication
• RS 232 with Modbus RTU or ASCII
via RJ-11 connector
• RS 485 with Modbus RTU or ASCII
via terminal strips
• Optional: SmartLinx cards for
- PROFIBUS DP
- DeviceNet
Rated operating conditions
1)
Installation conditions
Location
Indoor/outdoor
Installation category
II
Pollution degree
4
Ambient conditions
Ambient temperature (housing)
4/162
Siemens FI 01 · 2016
-20 ... +50 °C (-4 ... +122 °F)
CE, RCM2)
Lloyd’s Register of Shipping
ABS Type Approval
FM, CSAUS/C, UL listed
CSA Class I, Div. 2, Groups A, B, C,
and D, Class II, Div. 2, Groups F and
G, Class III (wall mount only), ATEX
II 3D
Program range is defined as the empty distance to the face of the transducer plus any range extension
2) EMC performance available on request
© Siemens AG 2016
Level Measurement
Continuous level measurement - Ultrasonic controllers
MultiRanger 100/200
Selection and Ordering data
Article No.
Selection and Ordering data
MultiRanger 100/200
Versatile short to medium-range ultrasonic single
and multi-vessel level monitor/controller for virtually
any application in a wide range of industries
7ML5033-
Further designs
7 7 7 77 - 77
Please add "-Z" to Article No. and specify Order
code(s).
Stainless steel tag [69 x 50 mm (2.71 x 1.97 inch)]:  Y15
Measuring-point number/identification
(max. 27 characters) specify in plain text
Click on the Article No. for the online configuration in the PIA Life Cycle Portal.
Versions
MultiRanger 100, level measurement only
 1
MultiRanger 200, level, volume, flow, and differen-  2
tial measurements
Mounting, enclosure design
Wall mount, standard enclosure

Wall mount, 4 entries, 4 M20 cable glands included
Panel mount (CE, CSAUS/C, FM, UL)

Power supply
100 ... 230 V AC
12 ... 30 V DC


Number of measurement points
Single point version
Dual point version


Communication (SmartLinx)
Without module
SmartLinx PROFIBUS DP module
SmartLinx DeviceNet module
See SmartLinx product on page 4/374 for
more information.
Output relays
3 relays (2 Form A, 1 Form C), 250 V AC
6 relays (4 Form A, 2 Form C), 250 V AC
1 relay (1 Form A), 250 V AC
(available on MultiRanger 100 model only)
2)
A
B
C
A
B
Article No.
English
7ML1998-5FB06
German
7ML1998-5FB36
4
Other Operating Instructions
0
1
0
2

3



Operating Instructions
Note: The Operating Instructions should be
ordered as a separate item on the order.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
This device is shipped with the Siemens Level and
Weighing manual DVD containing the ATEX Quick
Start and Operating Instructions library.


Approvals
General Purpose CE, FM, CSAUS/C,

UL listed, RCM
CSA Class I, Div. 2, Groups A, B, C, and D; Class II, 
Div. 2, Groups F and G; Class III1)
ATEX II 3D2)

1)
Order code
1
2
3
SmartLinx PROFIBUS DP, English
7ML1998-1AQ03
SmartLinx PROFIBUS DP, German
7ML1998-1AQ33
SmartLinx DeviceNet, English
Note: The appropriate SmartLinx Operating
Instructions should be ordered as a separate line
on the order.
All literature is available to download for free, in a
range of languages, at http://www.siemens.com/
processinstrumentation/documentation
7ML1998-1BH02
Accessories
Handheld programmer
A5E36563512
Tag, stainless steel, 12 x 45 mm (0.47 x 1.77 inch),
one text line, suitable for enclosure
7ML1930-1AC
A
B
M20 cable gland kit (4 M20 cable glands,
4 M20 nuts, 4 washers)
7ML1930-1FV
C
Sunshield kit, 304 stainless steel
7ML1930-1GA
SITRANS RD100, loop powered display see Chapter 7
7ML5741-...
SITRANS RD200, universal input display with
Modbus conversion - see Chapter 7
7ML5740-...
SITRANS RD300, dual line display with totalizer
and linearization curve and Modbus conversion see Chapter 7
7ML5744-...
SITRANS RD500 web, universal remote monitoring
solution for instrumentation - see Chapter 7
7ML5750-...
For wall mount applications only
For standard enclosure wall mount, option A only
 We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol . For details see page 9/5 in the appendix.
Spare parts
Power Supply Board (100 ... 230 V AC)
7ML1830-1MD
Power Supply Board (12 ... 30 V DC)
7ML1830-1ME
MultiRanger 100/200/ HydroRanger 200 display,
non-HMI
7ML1830-1MF
 We can offer shorter delivery times for configurations designated with the
Quick Ship Symbol . For details see page 9/5 in the appendix.
Siemens FI 01 · 2016
4/163
© Siemens AG 2016
Level Measurement
Continuous level measurement - Ultrasonic controllers
MultiRanger 100/200
■ Dimensional drawings
■ Schematics
Wall mount version
14.9
160.3 (6.325)
(0.58)
15.2
130 (5.125)
(0.6)
Mounting
holes
Ø 4.3
(0.17) (x4)
TB1
See note 1
6.6
(0.26)
91
(3.58)
TB1
TB2
+
240 (9.45)
227 (8.93)
Cover
screws
(x6)
L2/N L1
-
- +
2
TB3
12 ... 30 V
SYNC
1
DC version
+
mA INPUT
+
SHIELD
Relay 1
1
Panel mount version
198 (7.80)
+
+
Relay 3
TS-3
Hand programmer
36
(1.40)
+
2
1
2
000 00
0 00
5
6
9
0
mA
3
4
7
8
P
PX X X
SHIELD
1
Relay 4
97
(3.82)
Relay 5
DISCRETE
INPUTS
2
COM
Relay 6
C
278 (10.94)
4
4 ... 20 mA
OUTPUTS
Relay 2
Housing
Mounting screw
(provided by customer)
Siemens
Mounting holes
recommends using a hole
(accessed under lid)
punch for drilling the holes.
Ø 4.3 (0.17) (x4)
Suitable location for
conduit entrances
Relays shown in released
state
Article number:
A5E36563512
RS 485
A
B
Note:
1. Use 2-core copper wire, twisted, with shield, for expansion up to
365 m (1 200 ft). Route cable in grounded metal conduit, separate
from other cables.
2. Verify that all system components are installed in accordance with
instructions.
MultiRanger 100/200, dimensions in mm (inch)
3. Connect all cable shields to the MultiRanger shield connections.
Avoid differential ground potentials by not connecting cable shields
to ground (earth) anywhere else.
4. Keep exposed conductors on shielded cables as short as possible
to reduce noise on the line caused by stray transmissions and noise
pickup.
MultiRanger 100/200 connections
4/164
Siemens FI 01 · 2016