LITTELFUSE SP03-XBTG

Silicon Protection Arrays
Application Guide
10/100 Ethernet
Considerations:
● 10/100 relates to the data rate in Mbps (i.e. 10Mbps and 100Mbps)
→ For 10 Base-T, data is transmitted over 2 UTP (unshielded twisted pairs) using a 10MHz clock
→ For 100Base-TX, data is transmitted over 2 UTP using a 125MHz clock
● For these data rates the parasitic capacitance needs to be taken into account to preserve signal integrity
● The 4 data lines below (Tx+/- and Rx+/-) are being protected against intra-building (i.e. 100A, tP=8/20us) lightning
transients by a two stage protection scheme
Application Schematic:
RJ-45
Connector
*Package is shown as transparent
Tx+
J1
TxOutside
World
Ethernet
PHY
Rx+
Rx-
J8
SP03 (x2)
NC
Case GND
Case GND
SP3050
Recommended SPA Devices:
Lightning
(tP=8/20μs)
150A
I/O
Capacitance
16pF
# of
Channels
2
VRWM
Packaging
SP03-xBTG
ESD Level
(Contact)
±30kV
3.3V,6V
SOIC-8
SP3050-04HTG
±20kV
10A
2.4pF
4
6V
SOT23-6
Ordering Number
©2009 Littelfuse, Inc
10