HH-1545-12 This filter configuration features significant insertion loss for filtering DC/DC converters that need to meet the requirements of Mil-Std-461E, EN55022 or the FCC requirements. The pc board mounting facilitates placement of the filter close to the power modules thus helping to eliminate coupling due to magnetic radiation. Order P/N: HH-1545-12 Diel. Withstanding (line - case) = ___ 1500 Vdc (1.0 Min) Diel. Withstanding (line - line) = _____ 100 Vdc (1.0 Min) INSERTION LOSS vs. FREQUENCY INSERTION LOSS (db) Operating Voltage = _______________________50 Vdc Operating Current = _____________________12.0 Amp Operating Temperature = _______________(-40)—50°C 80 CM 70 60 DM 50 40 30 20 10 0 .01 .04 .02 .1 .07 .4 .2 1 4 10 40 100 .7 2 7 20 70 FREQUENCY (MEGAHERTZ) LINE 1 5 LOAD 4 3 2 PIN CONFIGURATION LOOKING FROM SIDE OPPOSITE THE PINS. USA JMK Inc 15 Caldwell Dr. Amherst, NH 03031 PH: 603 886-4100 FX: 603 886-4115 email: [email protected] PH: 44-(0) 7785310729 Fax: 44-(0) 141 589 1884 EUR JMK Inc Glasgow G13 1DN Scotland UK