JMK ZA-1536-10

JMK, Inc
ZA-1536-10
The ZA-1536-10 filter has been designed to operate
with the Mission power solutions “BADGER” power
supply. The combination will meet the requirements
of Mil-Std-461D or Mil-Std-461E.
Operating voltage (AC) = 115/120/200/220 V~
Operating Voltage (DC) = 100—375 Vdc
Operating current = 10 Amp
Operating frequency = DC—400 Hz
Operating temperature = (-55)—50C
Diel. withstanding (line - case) = 1500 Vac
Diel. withstanding (line - line) = 1500 Vdc
Leakage current = 0.4 ma Max. at 115 Vac, 400 Hz
Max residual voltage after 1 sec. = 34 Volts
1
L
2
N
3
G
Order P/N: ZA-1536-10
90
INSERTION LOSS (db)
80
70
DM
60
50
40
30
20
CM
10
0
.01
.04
.02
.1
.07
.4
.2
1
.7
4
2
10
7
40
20
FREQUENCY (MEGAHERTZ)
0.25 TAB TERM (3x)
6-32 INSERT (4PL)
N G L
3.030
3.88
2.430
0.60
0.29
0.90
0.25
1.745
0.25
2.000
2.24
2.50
0.25
2.00
0.25
1.75
1 2 3
6-32 INSERT (4PL)
USA
JMK Inc 15 Caldwell Dr. Amherst, NH 03031
PH: 603 886-4100
FX: 603 886-4115
email: [email protected]
PH: 44-(0) 7785310729 FX: 44-(0) 141-589-1884
EUR
JMK Inc Glasgow G13 1DN Scotland UK
100
70