GAS system Series 400 natural gas 400V / 50 Hz NOx < 500 mg/Nm3 System Ratings Gas genset with optional heat recovery (90°/70°C heating water circuit) Genset Engine Type Type MTU 6R400 GS* E3066 D4* MTU 6R400 GS E3066 L9 MTU 6R400 GS E3066 L9 MTU 6R400 GS E3066 L9 MTU 6R400 GS E3066 Z5 MTU 12V400 GS* E3042 D4* MTU 12V400 GS E3042 L9 MTU 12V400 GS E3042 L9 MTU 12V400 GS E3042 Z6 MTU 12V400 GS E3042 Z6 Output Elect.1) Therm.2) Exhaust3) Low Temp. kWel. kWth. kWth. (°C) kWth. (°C) 135 115 89 (90) - - - 182 122 143 (120) - - - 191 103 149 (120) 29 (50) 201 106 154 (120) 36 (40) 220 117 134 (120) 17 (40) 245 224 154 (100) - - - 357 235 256 (120) - - - 370 194 263 (120) 52 (50) 390 233 241 (120) 28 (40) 420 247 257 (120) 31 (40) Energy input4) kW 371 506 534 560 558 675 952 988 995 1064 Efficiency Electr. Total ntot (%) nel. (%) 36.4 91.4 36.0 88.3 35.8 83.0 35.9 82.3 39.4 84.4 36.3 92.3 37.5 89.1 37.4 83.7 39.2 86.8 39.5 86.8 Energy input4) kW 337 465 628 879 Efficiency Electr. Total ntot (%) nel. (%) 34.4 90.8 35.5 87.3 36.1 92.0 36.7 88.6 Methane number5) ≥ 70 ≥ 70 ≥ 70 ≥ 70 ≥ 80 ≥ 70 ≥ 70 ≥ 70 ≥ 70 ≥ 80 Cogeneration Module 100°/80°C heating water circuit Genset Engine Type Type MTU 6R400 GS* E3066 DH3* MTU 6R400 GS E3066 LH9 MTU 12V400 GS* E3042 DH3* MTU 12V400 GS E3042 LH9 Output Elect.1) Therm.2) Exhaust3) Low Temp. kWel. kWth. kWth. (°C) kWth. (°C) 116 110 80 (120) - - - 165 111 130 (120) - - - 227 210 141 (120) - - - 323 206 250 (120) - - - * = 1 with 3-Way-Catalyst, NOx < 250 mg/Nm3 1) Rated power at nominal voltage, power factor = 1,0 and nominal frequency 2) Heat output from engine cooling with tolerance of ± 8% 3) Heat output from exhaust (exhaust cooling to 90°C, 100°C or 120°C) with tolerance of ± 8% 4) Performance data in accordance with ISO 3046/I-2002 with tolerance of 5% 5) Referenced methane number Project specific data on reques: - different alternator voltage - different flow-/return-temperatures, hot cooling, methane number, installation conditions etc. - Container Methane number5) ≥ 70 ≥ 70 ≥ 80 ≥ 70 DS EMA 1 M12*1.5 H Drawings and dimensions SS 93.25114-0067 93.25114-0067 TP65-230/2/50Hz W B L Note: This drawing is provided for reference only and should not be used for installation planning. Dimensions Genset (L x W x H) - - - 3400 x 1700 x 2100 mm 3900 x 1900 x 2150 mm 4000 x 1700 x 2200 mm 4000 x 1700 x 2200 mm - - - - - - - - - Cogeneration module (L x W x H) 3650 x 960 x 1875 mm 3700 x 1900 x 2100 mm 3900 x 1900 x 2150 mm 3700 x 1900 x 2300 mm 3900 x 1900 x 2300 mm 3950 x 960 x 1875 mm 3900 x 1900 x 2100 mm 4000 x 1900 x 2300 mm Engine Data 3066 Configuration No. of cylinders Bore/Stroke Cyl. displacement Rated speed in-line 6 130/155 mm 2.06 lit. 1500 rpm 3042 Configuration No. of cylinders Bore/Stroke Cyl. displacement Rated speed 90°V 12 130/142 mm 1.88 lit. 1500 rpm design and equipment (extract) // Sliding gear starter 24V // Gas supply with electronically controlled gas metering valve // Electronic high-voltage capacitor ignition system with one ignition coil per cylinder // Electronic speed governor for speed and power output control with automatic knocking control Any specifications, descriptions, values, data or other information related to dimensions, power or other technical performance criteria of the goods as provided in this general productinformation are to be understood as non-binding and may be subject to further changes such as but not limited to technical evolution at any time. Version: 01.01.2016, materials and specifications subject to change without notice due to technical advances. MTU Onsite Energy A Rolls-Royce Power Systems Brand www.mtuonsiteenergy.com Subject to change. | 3232571 | Edition 01/16 | ENC 2016-01 | Printed in Germany on chlorine-free bleached papaer. Genset Type MTU 6R400 GS (D4) MTU 6R400 GS (L9) MTU 6R400 GS (Z5) MTU 12V400 GS (D4/L9) MTU 12V400 GS (Z6) MTU 6R400 GS (DH3) MTU 6R400 GS (LH9) MTU 12V400 GS (DH3/LH9/ZH6)