Gas Generator Sets: Series 4000 Biogas 400 V / 50 Hz

GAS SYSTEM
SERIES 4000 BIOGAS
400 V / 50 Hz
NOx < 500 mg/Nm3
SYSTEM RATINGS
Gas genset with optional heat recovery
Genset
Type
Engine
Type
MTU 8V4000 GS
MTU 12V4000 GS
MTU 16V4000 GS
MTU 20V4000 GS
L32
L32
L32
L32
Output
Elect.1)
kWel.
800
1169
1560
1950
Therm.2)
kWth.
392
572
628
736
Exhaust3) Low Temp.
kWth. (°C) kWth. (°C)
402 (120) 78 (40)
603 (120) 103 (40)
800 (120) 318 (40)
1048 (120) 394 (40)
1) Rated power at nominal voltage, power factor = 1,0 and nominal frequency
2) Heat output from engine cooling with tolerance of ± 8%
3) Heat output from exhaust (exhaust cooling to 120°C) with tolerance of ± 8%
4) Performance data in accordance with ISO 3046/I-2002 with tolerance of 5%
5) Referenced methane number
Project specific data on request:
- different alternator voltage
- different flow-/return-temperatures, hot cooling, methane number, installation conditions etc.
- Container
Energy
input4)
kW
1861
2719
3616
4502
Efficiency
Electr.
nel. (%)
43.0
43.0
43.1
43.3
Total
ntot (%)
85.7
86.2
82.6
82.9
Methane
number5)
≥ 120
≥ 120
≥ 120
≥ 120
DRAWINGS AND DIMENSIONS
Note: This drawing is provided for reference only and should not be used for installation planning.
Genset Type
MTU 8V4000 GS
MTU 12V4000 GS
MTU 16V4000 GS
MTU 20V4000 GS
Dimensions Genset (L x W x H)
4200 x 2000 x 2400 mm
5000 x 2000 x 2400 mm
5500 x 2000 x 2600 mm
6000 x 2000 x 2600 mm
Heat recovery module (Lh x W x H)
1500 x 1900 x 2000 mm
1500 x 1900 x 2000 mm
1500 x 1900 x 2000 mm
1500 x 1900 x 2000 mm
4000
Configuration
No. of cylinders
Bore/Stroke
Cyl. displacement
90° V
8/12/16/20
170/210 mm
4.77 lit.
DESIGN AND EQUIPMENT (EXTRACT)
// Sliding gear starter 24V
// Gas supply with electronically controlled gas metering valve
// Electronic high-voltage capacitor ignition system with one ignition coil
per cylinder
// Electronic speed governor for speed and power output control with
automatic knocking control
Any specifications, descriptions, values, data or other information related to dimensions, power or other technical performance criteria of the goods as provided in
this general productinformation are to be understood as non-binding and may be subject to further changes such as but not limited to technical evolution at any time.
Version: 01.08.2014, materials and specifications subject to change without notice due to technical advances.
MTU Onsite Energy
A Rolls-Royce Power Systems Brand
www.mtuonsiteenergy.com
Subject to change. | 3234721 | Edition 02/14 | ENC 2014-08 | Printed in Germany on chlorine-free bleached papaer.